BB08
O08The $x2000 adds a new dimension to L&T's AC drive solutions. Built to L&q's stringent quality
standards, the $x2000 is tested and certified to meet global benchmarks, giving you the assurance
of total reliability. The $x2000 is built to deliver powerful performance. It produces a starting torque
of 200% at 0.5 Hz, which provides better control at low-speed, Its compact size enables panel-size
reduction, hence helps in space-efficient design
Main Features
= Range: 0.75kW to 90kW
= Vif, Sensorless Vector Control,
Slip Compensation
= Starting Torque at 200% at 0.5Hz
for Sensorless Control
= Component Life Monitor
"Peer to Peer Communication to
share VOs
™ Built-in PLC Logic
= Built-in Brake Control
= Multi Keypad
= Stores last 5 faults
= Conformal Coating complying to
IEC 60721-3-3 class 3C2
= Builtin RS485 Modbus RTU
‘Communication
Applications
= OEM Machines
= Elevators
™ Plastic & Textile Machines
= Conveyors
= Compressors
= Wire Drawing
= extruders
= AHU Control
= Fan & Pump
™ Crane Hoist
= Crane Control LT/ CT
™ Solar PumpSmareDrive
ear Features
Multi-keypad function
Single LCD keypad can be used to sel up the parameters of
S435 connected drives.
+ LCD (LTOP-DOP-200) keyoad (same as Fx2000 model)
‘enables handy parameter set-up.
+ Multslanguage support ava lable
User sequence function (PLC Logic)
+ Simple PLC sequences can be operated with various
function block combinations with direct access to Drive
parameters.
+ Function blocks: AND, NOR, ADD, SUB, XOR, MIN, MAX,
COMPARE, TIMER, SWATCH, UP/DWN COUNT. etc
+ No Software required to create logic
Peer-to-Peer function embedded
Corman Po Vo can be shared among master and slave drives.
—— (85485 wiring required).
Built-in Brake Control
+ Brake opening command by drive under the following
conditions:
Inverter Output Frequency > Brake Release
Frequency
+ Inverter Output Current > Brake Release Current
* Brake release with delay
* Ensures Slip prevention
© Brake Close frequency different settings possible for
Hoisting & Lowering Motion
Safety Function
532000 has in-built safety functions conforming te modern
safety standards
The safety input function meets EN ISO 13849-1 PLd and EN,
61508 51.2 (EN60704-1, stop category 0)
This feature is standard and enables compliance with curent
salely standardsSmar Drive
> $x2000 Features
eo
== Powerful sensorless
oe She control
tee
ze Stating torque of 20090 Sz
se ' produced and provides robust
a power inthe lot sped region
oa The motor auto-tuning uneton
Se ‘soptmsed a maumse motor
Tee performance
Flying-start function
Drive capable of reliable and
smooth restarts even for
bi-directional rotating loads
‘nia installation
Main capacitor
lifecycle estimation
Estimated through monitoring the
change in the capacitance value
cnt Feedback when capacitor
capacity changes
Fan lifecycle onl
estimation ares
‘Warning signal is displayed
‘when fan is operated over a
certain amount of hoursSmareDrive
$x2000
Simple cooling fan replacement
Toolless replacement of cooling fan without dismantling
the drive
Built-in DC reactor
Effective in improving power factor and decreasing THD.
+ 3-phase 400V 37-8040 (ND)
DriveConnect software allows drivesystem
monitoring on a PC and easy maintenance
of drive and motor parameters
* Windows-based graphic user interface (GUI)
+ Modbus-R1U
* Connecting up to 31 drives
+ Integrated control console
* Offie editing function
+ Data uploadidownload
» 4-channel oscilloscope
+ Trigger function
Driveconnect software connection with R145 port for entire x2000 series
Features
Optional Accessories - easy to install & use
© Profibus-DP (uICl#0=.5})
© Modbus TCP / Ethernet IP (LICHETH-S
© CANopen {TCLCANS)
"V0 Expansion Card (\T10-Ex?-S,)
* Optional fieldbus
networks:
* Digitalinout_ = 3 (PNP/NEND
+ Digital output 2 (R) AC 2S0V- 1A/DC 30V- 1
* Aaloginput = 2,1 Vallage C10 10 +100),
arent (0 lo 20mA) 1 Voltage (0 to +10¥)
Voltage (0 to +10¥)/ 1 Current to 20m)
whe
+ Analogoutout = 1
-
Flange type
To reduce heat losses inside the panel
The heatsink can be mounted outside ofthe panel in case the
space is imited
Dual rating operation
Designed to be used for heavy and normal duty apelcations.
Overload capacity
= Heavy duly operation 150% of ratedcurrent, 60 seconds
= Normal duty operation 120% of rated current, 60 secondsSrarDrive
”$x2000 Specifications
Input and output specification: Input Voltage Single-Phase 230V (0.75 to 3.7kW - ND)
my HP 05 10 20 oo
pplabe 70) ew oa on. 5 2
Meter Womat 1 10 20 30 so
ty INO) as 15 22 ar
Capaciy ese uty HO} 10 19 30 a
ton) Norma uy 0} 2 2 ba as
utpet tates Heo Duty HO 25 50 to no
ating CorEIAL Normal Duty ND] 2 6 o6 ro
Frequency 0-40 Serr 0-1
atage V) 2 gave 20-2000
‘ape phe 200-2000 F540)
Input Frequeny Sos 5
Retog pated | Hea Duty “ 2 we a
rer] Norma uy] sa a wa 240
ply LED Leb tonal
Braking it ui
Input and output specification: Input Voltage Three-Phase 230V (0.75 to 18.5kW - ND)
tewy HP as) |S TSS
pptaa PHO] we aS TSO
Meter Noma HP 1m 30a 7S) too t5D m8 5
ayo) ew ass | SSS |S
canacty —MenyDuyO) 10S
vs} wormatouyio) 12S
oupt tated MenyDuyND] 2S Sato town
aun Garena) Noonalouyio) 31630)
freuen el 00H Sea 0-120
‘age pe 20-240"
otge V1 Se 20-24NAC FISK - 410%)
Input Feguency Soh)
Mates nated HewwyDuyiWO) 2? |||) | Sa) | Soe)
GirentiAl Normatouyeo) 0s) st)
ply LED TLD eponat
raking Unit hatinSrarDrive
”$x2000 Specifications
Input and output specification: Input Voltage Three-Phase 415V (0.75 to 30kW - ND)
eny as | 19 2038S TS | N00 150 0050900
pliable POL aw O81 ao SS TSO SOs
Mer Normal 1020) 0 | S075 | 100 | 150 | «m0 sao ao
ayn) aw os 1S a SS) 7S | tO WSO SO 300
capacity Hew DuytWO] 08S Ra
(wal wommalouyino] | 1S | aa) 53 | TH a? |S ms) m0 sake
apt aned = sHeawyDuyiHO] |) 28a) 8” | ta] eae]
ate GurentiAlwormalutyIND] | 20~|=xI S68 100 | «WO ||MO aK Sk
Frequency ‘AH ese 0-12
ape 1 “hie 20-€000
lage M1 Se Dt- AOAC FISK - 108)
Frequency S06 (5)
Mts aged sHeawyouyin) | ui | za | a2) sa | oe | ne | ts | ms | ma | Os [sar
aremiAl “WomalDuyiNO] 20) 2335S) S| TOSS SACHA SS
cheater tel onto
Dislay Le Ue pia)
Braking Unit ula
Input and output specification: Input Voltage Three-Phase 415V (37 to 90kW - ND)
28 sa 00 88 1o00
ay
ype | PAHO) ew oa na 59 a 50
Mater Normal 09 on 130 100 imo
muy O1 aw aa a 0 a S00
Capscly—_ eeyDuy 0) 5 sa sa as ss
ert Dt) sa oa ns v2 ua
cuiget tated Hse Dity 0) sa a a0 1100 ‘20
athg Garena] oma uy) sa 10 m9 ims 0
regen el ean ese 2
Yetageim phe 20-4801
Yetase Yale 0 AROVAC L8H - 108)
topo Fegeny he 50-6 oS)
Rating gated Heavy Duty [HO] sea 0 0 109 sao
Sit A) ma ty) ea 50 1280 ea 100
ocreacer hin
Dipay
‘raking ait ‘cel opinSmareDrive
$x2000
Range
Endosure Type
Overload Capacity
‘Max Output Voltage
‘Max Output Frequency
Rated Voltage
Rated Frequency
Keypad
Braking Chopper
DC Reactor
Control Method
Starting Torque
Frequency Control Range
Frequency Precision Setting
Standard Specifications
Frequency Setting
‘Output Frequency Resolution
VIF pattern
AcceVDecel Time
Braking Torque
Features
Faults
Alarm
Protection
Momentary Power Loss Ride
Through
1
0
Al
0
Interface
Puls Train
‘Communication
Safety UP
Area of Use
‘Ambient Temperature
Storage Temperature
PCB Protection
‘Application Humidity
Altitude
Vibration
‘Global Compliance
Environment
Specifications
Single-Phase 230V Three-Phase 230V ‘Three-Phase 415V
(0.75 to 3.7KW (ND) 0.75 to 18,5kW (ND) 0.75 to S0kW (ND)
P20
HO: 150% for Imin; NO: 120% for tin
Proportional to Input Voltage
© to 400Hz (Sensorless: Oto 120H2)
380 to 480V Three-phase (-159H/+10%)
Buil-in LED tll 30kW (ND) & Above 30KW standard Detachable LcD
Bult-in upto 30kW (ND)
Built-in from 37W to S0KW
Vif Sensorless Vector Conta, Slip Compensation
200% at 0.SH2 for Sensorless Contol & 150% at 3H2 for VIF
(0.0 to 400K for VIF, 0 to 120H2for Sensorless Vector Control
Digital command: 0.01H2
Analog command: 0,03H2 (Max, frequency: 60H)
‘Analog type - 10 to 10¥, +0 to 101M, 4 to 20(mAl
Digital type: Keypad, panel potentiometer, pulse tain input
ootte
Linear, squared, usr ViF
0.0 to 6000 Sec
Continuous Regeneration Torque 20% (150% with DBR)
Multi keypad, peer-to-peer communication to share UOs, user sequence, inbuilt PID, component life
‘monitor no motor detection, auto tuning, KEB, DIDO ON-OFF delay, torque contr, torque boost
DC braking, fre mode, ux braking, 2% motor, frequency ump, slip compensation
Under load trip. low voltage trip, phase loss wo, no mator wip, exterior brake trp safety input ero,
10 board trip inverter oveload warning lost command warning, overheat Tip, encode trip,
DBR SED warning
Command Los trip, overload, inverter overload, fan operation, resistance braking,
nos of corrections on roto auto tuning
Continuous Operation: Heavy Loads less then 1$msec, normal load less then Bmsec,
‘Auto Restart Operation: Heavy Loads more then 15msec, normal load more then Smsec
7 (Programmable NPNIPNP)
1 (Programmable NO/NC) + 1 TR ill 30KW,
2 (Programmable NOINC) +1 TR above 30K
2 (-20mA/- 10 0 + 10Vée)
4 (4-20mA 0 to 10Vde) til 30KW,
1 (420m) +1 (0 to 10¥de) above 30K
“LP & 1 OFP (0 to 32Khe)
Bult-in RS485 Modbus ATU
2, complying with EN ISO 13849-1 Pld and EN61S08SIL2 [EN6O204-1, stop category 0]
Indoor. There shall not be corrosive ait, combustbe gas, ol mist, dust and
ther pollutants
10°C to 50°C for HD, 10°C to 40°C for ND
20°C 10 65°C
Conformal Coating complying to IEC 60721-3-3 class 3€2
Below relative humidity 90% RH (no condensation)
Below 1000m
9.amisec' (16)
CE,UL, RohsSmareDrive
$x2000 Dimensions & Weights
2 |
B85)
Boo)
mmm — Mem 8 2 2 =
1
Ww i
4 ro)
Input Voge Dive cata wim) Mm) Din) Wash g)
Single Pase 230 Lovestoorona | 100 ne us 15
ivesaootnaa 100 ne 0 1s
Thre hase 415V LIVESaoooTeAR 100 ne 5 1sSmareDrive
$x2000 Dimensions & Weights
a
AG
Input lage Drv cat Ne Wine) Hmm) Din) Weight ts)
veerhase IVE Sa056HaA we 20 18 “
LIV e008 18 ma Ma »
IV e058 no 250 1 15
ec
Inpurvtiage Drive Gt Na Winn) Him Pin Weight a)
ir 2S sto 7 %
LIvesen baa RS sso 368 ©