100% found this document useful (1 vote)
59 views7 pages

Structural Load Analysis

This document summarizes the structural analysis of a member subjected to combined stresses from axial force and bending moments. It evaluates several sections of the member at different locations along its length based on criteria for tension members and compression members under combined stresses according to BS 5950: Part 1: 2000. Two sections are found to satisfy the criteria while one section fails the local capacity check for compression members.

Uploaded by

Nyu123456
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
59 views7 pages

Structural Load Analysis

This document summarizes the structural analysis of a member subjected to combined stresses from axial force and bending moments. It evaluates several sections of the member at different locations along its length based on criteria for tension members and compression members under combined stresses according to BS 5950: Part 1: 2000. Two sections are found to satisfy the criteria while one section fails the local capacity check for compression members.

Uploaded by

Nyu123456
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Member Design for Combined Stresses

Element 500-505
MOMENTS: X-X M max = -142.1kNm @ 4.20m
-150
Lx Eff = 4.200 m mx = .448
-100 Ly Eff = 4.200 m my = .403
Le Eff = 4.200 m mlt= .546
-50.0
Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Tension area factor (Ane/Ag) = 1.00
Flange class: 1 Web class : 1
50.0
Critical Load Case : C1

Section 254x146x43 I
MOMENTS: Y-Y M max = -.6700kNm @ 4.20m
-.600
BS 5950 : Part 1 : 2000
-.400 4.8.2 Tension members with moments
-.200 a) Local capacity check (Crit. pos.= 4.200 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Ft Mx My 4.42 142 .670
.200
---- + --- + --- = ---- + ---- + ---- = 0.94 OK
Pt Mcx Mcy 1510 156 30.4
.400
.600 b) Lateral torsional buckling under moments alone
mltMLT myMy 77.6 .270
AXIAL FORCE P max = -4.420kN @ 0.00m
------ + ---- = ---- + ---- = 0.88 OK
Mb Mcy 88.7 30.4
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

-1.00
Slenderness Ratio: L/r = 119 OK
-2.00
------------------------------------------------------------
-3.00

-4.00

Element 505-510 Evaluate current section


MOMENTS: X-X M max = -142.1kNm @ 0.00m
-150
Lx Eff = 4.200 m mx = .474
-100 Ly Eff = 4.200 m my = .403
Le Eff = 4.200 m mlt= .568
-50.0
Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Tension area factor (Ane/Ag) = 1.00


Flange class: 1 Web class : 1
50.0
Critical Load Case : C1

MOMENTS: Y-Y M max = -.7200kNm @ 0.00m


Section 254x146x43 I

-.600 BS 5950 : Part 1 : 2000


-.400 4.8.2 Tension members with moments
-.200 a) Local capacity check (Crit. pos.= 0.000 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Ft Mx My 4.47 142 .720


.200
---- + --- + --- = ---- + ---- + ---- = 0.94 OK
.400
Pt Mcx Mcy 1510 156 30.4
.600
b) Lateral torsional buckling under moments alone
mltMLT myMy 80.8 .290
AXIAL FORCE P max = -4.470kN @ 0.00m
------ + ---- = ---- + ---- = 0.92 OK
Mb Mcy 88.7 30.4
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

-1.00
Slenderness Ratio: L/r = 119 OK
-2.00
------------------------------------------------------------
-3.00

-4.00
Element 501-506 Evaluate current section
MOMENTS: X-X M max = -153.0kNm @ 4.20m
-150
Lx Eff = 4.200 m mx = .446
-100 Ly Eff = 4.200 m my = .416
Le Eff = 4.200 m mlt= .539
-50.0 Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Tension area factor (Ane/Ag) = 1.00
Flange class: 1 Web class : 1
50.0
Critical Load Case : C1

MOMENTS: Y-Y M max = -.6200kNm @ 4.20m


Section 254x146x43 I
-.600
BS 5950 : Part 1 : 2000
-.400 4.8.3 Compression members with moments
-.200 4.8.3.2 Local capacity check (Crit. pos.= 4.200 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Fc Mx My .330 153 .620
---- + -- + ---- = ---- + ---- + ---- = 1.00 FAIL
.200 AgPy Mcx Mcy 1510 156 30.4
.400
4.8.3.3 Overall buckling check
4.8.3.3.1 Simplified approach
AXIAL FORCE P max = .3300kN @ 0.00m
Fc mxMx myMy .330 68.2 .258
-- + --- + ---- = ---- + ---- + ---- = 0.50 OK
.300 Pc PyZx PyZy 596 139 25.3
.250
.200
Fc mltMLT myMy .330 82.4 .258
--- + ------ + ---- = ---- + ---- + ---- = 0.94 OK
.150
Pcy Mb PyZy 596 88.7 25.3
.100
.050 4.8.3.3.2 More exact approach
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Fc mxMx Fc myxMy .330 68.2 .330 .258


-- + ---(1+0.5--)+ 0.5---- = --- + ---(1+0.5---)+ 0.5---= 0.44 OK
Pcx Mcx Pcx Mcy 1430 156 1430 30.4

Fc mltMlt myMy Fc .330 82.4 .258


-- + ------ + ----(1+---) = ---- + ---- + ----(1.00)= 0.94 OK
Pcy Mb Mcy Pcy 596 88.7 30.4

mxMx(1+0.5Fc/Pcx) myMy(1+Fc/Pcy) 68.2 .258


---------------- + -------------- = ---- + ---- = 0.45 OK
Mcx(1-Fc/Pcx) Mcy(1-Fc/Pcy) 156 30.3

Slenderness Ratio: L/r = 119 OK

------------------------------------------------------------

Element 506-511 Evaluate current section


MOMENTS: X-X M max = -153.0kNm @ 0.00m
-150
Lx Eff = 4.200 m mx = .456
-100 Ly Eff = 4.200 m my = .414
Le Eff = 4.200 m mlt= .547
-50.0 Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Tension area factor (Ane/Ag) = 1.00


Flange class: 1 Web class : 1
50.0
Critical Load Case : C1

Section 254x146x43 I
MOMENTS: Y-Y M max = -.6900kNm @ 0.00m

-.600 BS 5950 : Part 1 : 2000


-.400 4.8.3 Compression members with moments
-.200 4.8.3.2 Local capacity check (Crit. pos.= 0.000 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Fc Mx My .340 153 .690


---- + -- + ---- = ---- + ---- + ---- = 1.01 FAIL
.200
AgPy Mcx Mcy 1510 156 30.4
.400
.600 4.8.3.3 Overall buckling check
4.8.3.3.1 Simplified approach
AXIAL FORCE P max = .3400kN @ 0.00m
Fc mxMx myMy .340 69.8 .286
.350 -- + --- + ---- = ---- + ---- + ---- = 0.52 OK
.300 Pc PyZx PyZy 596 139 25.3
.250
Fc mltMLT myMy .340 83.7 .286
.200
--- + ------ + ---- = ---- + ---- + ---- = 0.96 OK
.150 Pcy Mb PyZy 596 88.7 25.3
.100
.050 4.8.3.3.2 More exact approach
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Fc mxMx Fc myxMy .340 69.8 .340 .286


-- + ---(1+0.5--)+ 0.5---- = --- + ---(1+0.5---)+ 0.5---= 0.45 OK
Pcx Mcx Pcx Mcy 1430 156 1430 30.4
Fc mltMlt myMy Fc .340 83.7 .286
-- + ------ + ----(1+---) = ---- + ---- + ----(1.00)= 0.95 OK
Pcy Mb Mcy Pcy 596 88.7 30.4

mxMx(1+0.5Fc/Pcx) myMy(1+Fc/Pcy) 69.8 .286


---------------- + -------------- = ---- + ---- = 0.46 OK
Mcx(1-Fc/Pcx) Mcy(1-Fc/Pcy) 156 30.3

Slenderness Ratio: L/r = 119 OK

------------------------------------------------------------

Element 502-507 Evaluate current section


MOMENTS: X-X M max = -100.4kNm @ 4.20m
-100
-80.0
Lx Eff = 4.200 m mx = .400
Ly Eff = 4.200 m my = .413
-60.0
Le Eff = 4.200 m mlt= .468
-40.0
Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
-20.0 Tension area factor (Ane/Ag) = 1.00
Flange class: 1 Web class : 1
20.0
40.0 Critical Load Case : C1

Section 254x146x43 I
MOMENTS: Y-Y M max = -.6100kNm @ 4.20m
-.600
BS 5950 : Part 1 : 2000
-.400
4.8.2 Tension members with moments
-.200 a) Local capacity check (Crit. pos.= 4.200 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Ft Mx My .280 100 .610


---- + --- + --- = ---- + ---- + ---- = 0.67 OK
.200
Pt Mcx Mcy 1510 156 30.4
.400
b) Lateral torsional buckling under moments alone
mltMLT myMy 47.0 .252
AXIAL FORCE P max = -.2800kN @ 0.00m
------ + ---- = ---- + ---- = 0.54 OK
Mb Mcy 88.7 30.4
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

-.050
Slenderness Ratio: L/r = 119 OK
-.100

-.150 ------------------------------------------------------------
-.200

-.250
Element 507-512 Evaluate current section
MOMENTS: X-X M max = -100.4kNm @ 0.00m
-100
-80.0
Lx Eff = 4.200 m mx = .400
Ly Eff = 4.200 m my = .415
-60.0
Le Eff = 4.200 m mlt= .470
-40.0
Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
-20.0
Tension area factor (Ane/Ag) = 1.00
Flange class: 1 Web class : 1
20.0
40.0 Critical Load Case : C1

Section 254x146x43 I
MOMENTS: Y-Y M max = -.6800kNm @ 0.00m
-.600 BS 5950 : Part 1 : 2000
-.400 4.8.2 Tension members with moments
-.200 a) Local capacity check (Crit. pos.= 0.000 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Ft Mx My .280 100 .680
---- + --- + --- = ---- + ---- + ---- = 0.67 OK
.200
Pt Mcx Mcy 1510 156 30.4
.400
.600 b) Lateral torsional buckling under moments alone
mltMLT myMy 47.1 .282
AXIAL FORCE P max = -.2800kN @ 0.00m
------ + ---- = ---- + ---- = 0.54 OK
Mb Mcy 88.7 30.4
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

-.050
Slenderness Ratio: L/r = 119 OK
-.100

-.150 ------------------------------------------------------------
-.200

-.250

Element 3-400 Evaluate current section


MOMENTS: X-X M max = 229.3kNm @ 4.80m

Lx Eff = 4.800 m mx = .763


.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

50.0
Ly Eff = 4.800 m my = .403
Le Eff = 4.800 m mlt= .757
100 Py = 275 MPa
Tension area factor (Ane/Ag) = 1.00
150
Flange class: 1 Web class : 1
200
Critical Load Case : C1

MOMENTS: Y-Y M max = 3.030kNm @ 0.00m


Section 457x191x67 I
-3.00
BS 5950 : Part 1 : 2000
-2.00
4.8.3 Compression members with moments
-1.00 4.8.3.2 Local capacity check (Crit. pos.= 4.800 m)
Fc Mx My 2.33 229 2.99
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

---- + -- + ---- = ---- + ---- + ---- = 0.63 OK


1.00
AgPy Mcx Mcy 2350 404 50.5
2.00

3.00 4.8.3.3 Overall buckling check


4.8.3.3.1 Simplified approach
AXIAL FORCE P max = 2.330kN @ 0.00m
Fc mxMx myMy 2.33 175 1.22
-- + --- + ---- = ---- + ---- + ---- = 0.52 OK
2.00
Pc PyZx PyZy 966 358 42.1

1.50 Fc mltMLT myMy 2.33 174 1.22


--- + ------ + ---- = ---- + ---- + ---- = 0.88 OK
1.00 Pcy Mb PyZy 966 205 42.1
.500
4.8.3.3.2 More exact approach
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Fc mxMx Fc myxMy 2.33 175 2.33 1.22


-- + ---(1+0.5--)+ 0.5---- = --- + ---(1+0.5---)+ 0.5---= 0.45 OK
Pcx Mcx Pcx Mcy 2310 404 2310 50.5

Fc mltMlt myMy Fc 2.33 174 1.22


-- + ------ + ----(1+---) = ---- + ---- + ----(1.00)= 0.87 OK
Pcy Mb Mcy Pcy 966 205 50.5

mxMx(1+0.5Fc/Pcx) myMy(1+Fc/Pcy) 175 1.22


---------------- + -------------- = ---- + ---- = 0.46 OK
Mcx(1-Fc/Pcx) Mcy(1-Fc/Pcy) 404 50.4

Slenderness Ratio: L/r = 117 OK

------------------------------------------------------------
Element 51-400 Evaluate current section
MOMENTS: X-X M max = -301.0kNm @ 0.00m
-300
Lx Eff = 4.200 m mx = .414
-200 Ly Eff = 4.200 m my = .450
-100
Le Eff = 4.200 m mlt= .440
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Py = 275 MPa
Tension area factor (Ane/Ag) = 1.00
100 Flange class: 1 Web class : 1
200 Critical Load Case : C1

MOMENTS: Y-Y M max = 1.200kNm @ 0.00m


Section 457x191x67 I
-1.00
BS 5950 : Part 1 : 2000
-.500 4.8.3 Compression members with moments
4.8.3.2 Local capacity check (Crit. pos.= 0.000 m)
Fc Mx My 1.27 301 1.20
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

---- + -- + ---- = ---- + ---- + ---- = 0.77 OK


.500
AgPy Mcx Mcy 2350 404 50.5
1.00
4.8.3.3 Overall buckling check
4.8.3.3.1 Simplified approach
AXIAL FORCE P max = 1.270kN @ 0.00m
Fc mxMx myMy 1.27 125 .540
-- + --- + ---- = ---- + ---- + ---- = 0.36 OK
1.20
Pc PyZx PyZy 1170 358 42.1
1.00

.800 Fc mltMLT myMy 1.27 132 .540


--- + ------ + ---- = ---- + ---- + ---- = 0.58 OK
.600
Pcy Mb PyZy 1170 235 42.1
.400

.200 4.8.3.3.2 More exact approach


.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Fc mxMx Fc myxMy 1.27 125 1.27 .540


-- + ---(1+0.5--)+ 0.5---- = --- + ---(1+0.5---)+ 0.5---= 0.31 OK
Pcx Mcx Pcx Mcy 2320 404 2320 50.5

Fc mltMlt myMy Fc 1.27 132 .540


-- + ------ + ----(1+---) = ---- + ---- + ----(1.00)= 0.58 OK
Pcy Mb Mcy Pcy 1170 235 50.5

mxMx(1+0.5Fc/Pcx) myMy(1+Fc/Pcy) 125 .541


---------------- + -------------- = ---- + ---- = 0.32 OK
Mcx(1-Fc/Pcx) Mcy(1-Fc/Pcy) 404 50.4

Slenderness Ratio: L/r = 102 OK

------------------------------------------------------------
Element 51-401 Evaluate current section
MOMENTS: X-X M max = -299.9kNm @ 0.00m
-300
Lx Eff = 4.200 m mx = .444
-200 Ly Eff = 4.200 m my = .455
Le Eff = 4.200 m mlt= .440
-100
Py = 275 MPa
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Tension area factor (Ane/Ag) = 1.00
Flange class: 1 Web class : 1
100
Critical Load Case : C1

MOMENTS: Y-Y M max = -1.130kNm @ 0.00m


Section 457x191x67 I
-1.00 BS 5950 : Part 1 : 2000
4.8.3 Compression members with moments
-.500 4.8.3.2 Local capacity check (Crit. pos.= 0.000 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00
Fc Mx My 1.12 300 1.13
---- + -- + ---- = ---- + ---- + ---- = 0.76 OK
AgPy Mcx Mcy 2350 404 50.5
.500
4.8.3.3 Overall buckling check
4.8.3.3.1 Simplified approach
AXIAL FORCE P max = 1.120kN @ 0.00m
Fc mxMx myMy 1.12 133 .514
-- + --- + ---- = ---- + ---- + ---- = 0.39 OK
1.00 Pc PyZx PyZy 1170 358 42.1
.800
Fc mltMLT myMy 1.12 132 .514
.600 --- + ------ + ---- = ---- + ---- + ---- = 0.57 OK
Pcy Mb PyZy 1170 235 42.1
.400

.200 4.8.3.3.2 More exact approach


.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

Fc mxMx Fc myxMy 1.12 133 1.12 .514


-- + ---(1+0.5--)+ 0.5---- = --- + ---(1+0.5---)+ 0.5---= 0.34 OK
Pcx Mcx Pcx Mcy 2320 404 2320 50.5

Fc mltMlt myMy Fc 1.12 132 .514


-- + ------ + ----(1+---) = ---- + ---- + ----(1.00)= 0.57 OK
Pcy Mb Mcy Pcy 1170 235 50.5

mxMx(1+0.5Fc/Pcx) myMy(1+Fc/Pcy) 133 .514


---------------- + -------------- = ---- + ---- = 0.34 OK
Mcx(1-Fc/Pcx) Mcy(1-Fc/Pcy) 404 50.4

Slenderness Ratio: L/r = 102 OK

------------------------------------------------------------
Element 4-401 Evaluate current section
MOMENTS: X-X M max = 184.0kNm @ 4.49m
.500
Lx Eff = 4.800 m mx = .798
1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50
Ly Eff = 4.800 m my = .403
50.0 Le Eff = 4.800 m mlt= .790
Py = 275 MPa
100 Tension area factor (Ane/Ag) = 1.00
Flange class: 1 Web class : 1
150
Critical Load Case : C1

Section 457x191x67 I
MOMENTS: Y-Y M max = -3.180kNm @ 0.00m
-3.00
BS 5950 : Part 1 : 2000
-2.00 4.8.3 Compression members with moments
-1.00 4.8.3.2 Local capacity check (Crit. pos.= 4.800 m)
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Fc Mx My 2.44 183 3.14


---- + -- + ---- = ---- + ---- + ---- = 0.52 OK
1.00
AgPy Mcx Mcy 2350 404 50.5
2.00
3.00 4.8.3.3 Overall buckling check
4.8.3.3.1 Simplified approach
AXIAL FORCE P max = 2.440kN @ 0.00m
Fc mxMx myMy 2.44 147 1.28
2.50 -- + --- + ---- = ---- + ---- + ---- = 0.44 OK
Pc PyZx PyZy 966 358 42.1
2.00

1.50
Fc mltMLT myMy 2.44 145 1.28
--- + ------ + ---- = ---- + ---- + ---- = 0.74 OK
1.00 Pcy Mb PyZy 966 205 42.1
.500 4.8.3.3.2 More exact approach
.500

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Fc mxMx Fc myxMy 2.44 147 2.44 1.28


-- + ---(1+0.5--)+ 0.5---- = --- + ---(1+0.5---)+ 0.5---= 0.38 OK
Pcx Mcx Pcx Mcy 2310 404 2310 50.5

Fc mltMlt myMy Fc 2.44 145 1.28


-- + ------ + ----(1+---) = ---- + ---- + ----(1.00)= 0.74 OK
Pcy Mb Mcy Pcy 966 205 50.5

mxMx(1+0.5Fc/Pcx) myMy(1+Fc/Pcy) 147 1.28


---------------- + -------------- = ---- + ---- = 0.39 OK
Mcx(1-Fc/Pcx) Mcy(1-Fc/Pcy) 404 50.4

Slenderness Ratio: L/r = 117 OK

------------------------------------------------------------

You might also like