Electronic blood collection monitor
   Constant and uniform mixing of blood
   Automatic tare for the empty bag
   Automatic clamp at the end of the donation
   Adjustable low-high flow alarms
   Adjustable donation time-out
   Removable / rechargeable battery
                                                 HEMOTEK 2 is an accurate
                                                 electronic blood collection
                                                 monitor, designed to manage in
                                                 total safety and simplicity any
                                                 blood donations.
                                                                                        Electronic blood collection monitor
                                                                                         Optional Accessories
                                                                                        HTEK2.DB.22    Calibration mass 500 g.
                                                                                        HTEK2.DB.23    External battery charger*
                                                                                        HTEK2.DB.24    Rechargeable battery pack
                                                                                        HTEK2.DB.30    Aluminium transport hand case [it can work as stand too]
HEMOTEK 2 accepts any kind of bag with or without filters. A                            * The battery pack is automatically recharged when HEMOTEK2 is connected to
automatic tare to zero for the weight of the empty bag is done                          the line voltage. However, to charge any battery out of HEMOTEK2, this option
                                                                                        is necessary.
at every new donation. HEMOTEK 2 is equipped with a linear
mixing system capable to perform an excellent mixing of blood
with the anticoagulant. As standard is possible to adjust the low
and high flows alarms and the time out of the donation up to 20
minutes. Acoustics and visuals alarms are present as standards.                                     Calibration mass 500 g.
Automatic clamp of tubing at the end of each donation. Some
most used values can be set as default parameters, such as the
net target volume to collect, the flow alarms and the time-out.
Temporarily it is possible to adjust any different target volume
also during the collection. At the end of each collection the
display will alternatively shows the final net weight and the
donation time while an alarm warns the Operator.
                                                                                              Rechargeable battery pack
The balance system can be easily calibrated with a known mass
(optional not included) by a few simple operations.
With the optional battery pack HEMOTEK 2 can work without
power up to 80 donations becoming a powerful instrument for
mobile collection.                                                                                 Aluminum transport hand case 
Specifications:                                             TECHNICAL DATA
::   Weighing range from 0 to 990 ml                        Description:                 Electronic blood collection monitor
::   Automatic tare to zero for the empty bag               Trade name:                  HEMOTEK2
                                                                                                                                                                        The specification can be change without notice - Rev. 0 - 2005
::   Adjustable Low and High Flow alarms                    Sales code:                  HTEK2.DB.00
::   Adjustable donation time out [up to 20 minutes]        Class of protection:         1
::   Adjustable default values                              Type:                        CF
::   Automatic clamp of tubing at the end of the donation   Classification EEC
                                                            Dir. 93/42 EEC:              Class 1 - Medical device
                                                            Reference Standards:         EN 60601, EN 60601-1-2
                                                            Power supply:                115 / 230 VAC +/-10% or with optional battery pack
                                                            Line frequency:              50/60 Hz
                                                            Power consumption:           35 VA approximately
                                                            Fuses:                       2 x T315 mA
                                                            Using ambient conditions:    Temperature 10°÷40°Humidity 30÷75% RH without condensation at atmospheric
                                                                                         pressure of 700 - 1060 hPa
                                                            Type of mixing:              Linear with central support
                                                            Weighing range:              10 ÷ 990 ml (with minimum variation of 10 ml)
                                                            Accuracy:                    +/- 2% within the range 300 - 500 ml
                                                            Dimensions and weight:       300D x 200H x 250W mm about 3 Kg (without battery)
w w w . d e l c o n . i t
DELCON srl - 20043 Arcore (MI) - Italy - Via Matteucci, 25/27 - Phone +39 039.617670 - Fax +39 039.617677 - e-mail: info@delcon.it
                            2
Electronic blood collection monitor with data transmission
   3D mixing system
   Graphics display blu/white with white backlight
   Wireless and cable data transmission
   Memory card
   Barcode reader
   Removable / rechargeable battery
   Customizable barcode protocol on Windows® ambient
                                                  HEMOMIX2 is a modern blood
                                                  collection monitor designed with
                                                  most advanced technology.
                                                                                   Electronic blood collection monitor w ith data tra n sm issio n
                                                                                   is tough and very simple to calibrate: takes only few seconds
                                                                                   with a known calibration mass. With the optional removable -
                                                                                   rechargeable battery pack, HEMOMIX2 can work without power
                                                                                   for up to 50 donations. The battery pack can be charged
                                                                                   automatically inside the machine or by the optical external
                                                                                   battery charger.
                                                                                   Up to 255 Mixers can be connected on the same network.
                                                                                   Specifications:
                                                                                   :: Weighing range from 10 to 990 ml
                                                                                   :: Collected volume range adjustable with 1 ml steps
                                                                                   :: Adjustable upper safety limit for collected volume (typically 600 ml)
                                                                                   :: Automatic tare to zero for the empty bag
                                             2                                     :: Adjustable Low and High Flow alarms
                                                                                   :: Adjustable maximum donation time [up to 20 minutes]
                                                                                   :: Setting of two default volumes
HEMOMIX2 accepts all kinds of blood donor bags. 3D mixing
                                                                                   :: Automatic clamp of tubing at the end of donation
system guarantees best mixing of blood with anticoagulant.
                                                                                   :: Detection system on clamp for checking tube positioning
Adjustable alarms for low and high flow and set of maximum                         :: 3D mixing system
donation time up to 20 minutes.                                                    :: Five possible interface languages
Programmable default values for most common parameters of                          :: EU or US date format
collections. Volume to collect modifiable at any time during                       :: Configurable date and time
the donation too. Auto tare of the empty bag with automatic                        :: Three types customizable barcode protocols
clamp closing at the end of donation with audible and visual                       :: Cable or wireless for data handling - transmission
alarms (red light blinks on top of the clamp for easy identification               :: RS 232 port for barcode reader
too). Safety switch to control if tubing is well inserted into the                 :: Memory card for data storage
clamp. At end of each donation the display shows the final                         :: Firmware upgrading directly through computer
volume collected and the donation time in minutes and seconds.                     :: Tough weighing system
                                                                                                                                                                  The specification can be changed without notice - Rev. 02-2007 The pictures are only indicative
During the collection the graphic display shows: donation time,                    :: Weighing accuracy: ≤ +/- 3 ml or gr
collected volume and average donation flow. All collection data                    :: Up to 1000 donations can be stored on internal memory of HEMOMIX2
can be recalled and read from the mixer memory or transferred                      :: Service program for direct trouble shooting
onto the memory card (see options) or sent to the PC via
Wireless or cable (see options). Weighing system of HEMOMIX2
Optional Accessories
                                                       TECHNICAL DATA                                                                                         2
HMIX2.DB.22   Calibration mass 500 g                   Description:                 Electronic blood collection monitor with data transmission
HMIX2.DB.23   External battery charger 100 - 240 VAC   Trade name:                  HEMOMIX2
HMIX2.DB.24   Battery pack                             Sales code:                  HMIX2.DB.00
HMIX2.DB.30   Transport case (can be used as support   Class of protection:         1
              for mixer too)                           Type:                        CF
HMIX2.DB.31   Memory card                              EEC Classification           Class 1 Medical Device (93/43 MDD and Ita. D.L. 46/97)
HMIX2.DB.32   Wireless transmission module for         Reference Standards:         EN 60601-1 for Electrical safety and EN 60601-1-2 for EMC
              HEMOMIX2
                                                       Power supply:                230 / 115 VAC +/- 10% or with internal rechargeable battery
HMIX2.DB.33   RS485 converter for computer
              connection                               Line frequency:              50/60 Hz
HMIX2.DB.34   DCS - data collection software for       Power consumption:           45 VA
              Windows® PC                              Fuses:                       2 x T315 mA
HMIX2.DB.35   CCD barcode reader                       Using ambient conditions:    Temperature 10 ÷ 40 °C, humidity up to 90% RH without condensation
HMIX2.DB.36   Cable to connect two HEMOMIX2            Type of mixing:              3D with central support
              together or to a computer                Weighing range:              10 ÷ 900 ml or gr with safety upper limit adjustable
HMIX2.DB.37   Wireless module for computer             Accuracy:                    ≤ +/- 3 ml or gr
HMIX2.DB.38   Cable for firmware upgrading             Dimensions and weight:       350D x 221H x 273W mm about 3 Kg (without battery)
w w w . d e l c o n . i t
DELCON srl - 20043 Arcore (MI) - Italy - Via Matteucci, 25/27 - Phone +39 039.617670 - Fax +39 039.617677 - e-mail: info@delcon.it