Plate Heat Exchanger
4         Plate Cleaning Manual
Introduction
About this document
       In addition to this document, the Manuals for HISAKA PHEs consist of the following five documents. Read them thoroughly
        and understand the precautions regarding the safety of the equipment and its functions before handling the equipment.
        1 Installation Manual, 2 Operation and Maintenance Manual, 3 Gasketting Manual, 5 “Slit-In” Type Gasketting
        Manual, 6 Mixed Gasket Materials Manual
        You can also download these documents on our company website. http://www.hisaka.co.jp/english/
       This document is created for a person who fully understands the language it is written in. If a person, who is not able to
        understand the language written herein, will handle the equipment, please provide safety instructions to the
        personnel/operators.
       The PHE supplied may differ from the drawings and pictures in this document depending on the optional parts if any. Also,
        for the purpose of explanation, the drawings and pictures in these Manuals may omit the details, accessories, or the like.
       Changing the contents of these Manuals, in part or in whole, or using them for anything other than its intended purpose is
        prohibited.
       Keep these Manuals in hand.
 About plate cleaning
       To prevent injury and damages, do not clean plate other than for their intended purpose and specifications. Also, during
        maintenance, follow the instructions of related documents.
 About worker limitations
       Operation, maintenance/inspection, or installation of the equipment shall be performed by personnel/operators who have
        undergone training regarding safety and danger prevention drills.
       Work in high places should be carried out by a worker who fully understands the danger of the work and has received
        training in safety and danger prevention.
 Disposal of the material
       Disposal method is different in its kind of material. Please dispose it according to a security data sheet (SDS) packed with a
        product. In addition, please follow the local law and regulations.
 Disclaimer
       HISAKA accepts no liability for any failures in the function or performance of the equipment caused by use of any other than
        genuine parts.
       HISAKA accepts no liability for any injuries or damage borne by the user, caused by use of any other than genuine parts.
       HISAKA accepts no liability for any failures in the function or performance of the equipment caused by use of this equipment
        in a manner that does not adhere to the procedures indicated in this manual.
                         HISAKA Plate Heat Exchanger
                              Plate Cleaning Manual
Table of Contents
1   Safety Precautions                                 P1
2   What is the Plate-Clean Series?                    P2
3   How to Use                                         P2~3
4   Cleaning procedure                                 P3~4
5   Other Precautions                                  P5
6   Inquiries                                          P5
1       Safety Precautions
    Read through this manual carefully before use, and use PHE properly.
    If you have any questions, please inquire with our company.
   Precautions are categorized using the following symbols.
       WARNING                      This symbol indicates content where mishandling could result in death or severe injury.
        CAUTION                     This symbol indicates content where mishandling could result in injury or property damage.
            NOTE                    This symbol indicates important matters and/or useful information.
   Meanings of Symbols
       Indicates items that are "prohibited (something that you must                             Indicates items that are "mandatory (something that you must
       NOT do)".                                                                                 do)".
                                                                                              WARNING
       Do NOT operate in excess of the design conditions
       (temperature, flow rate, pressure, etc.).
       It may cause deformation of the heat transfer plates or leakage. Also, the required
       performance may not be achieved.
                                                                                              CAUTION
       Do NOT touch the side of the heat exchanger element (edge of the heat                     Request an expert to perform piping work, and review the assembly drawings
       transfer plates).                                                                         with them beforehand to ensure that connections are properly made.
       The edge of a heat transfer plate is very sharp and may cut you.                          Work performed by inexperienced personnel can result in a faulty or improper
       Be sure to wear cut-resistant gloves whenever touching the heat transfer plates.          connection. An improper connection can result in failure to provide the specified
                                                                                                 performance or an equipment malfunction.
       Do NOT place objects on the heat exchanger.
       Doing so may cause deformation of heat transfer plate or a falling object may cause
       injury during operation.
       Do NOT touch anything the side of the heat exchanger element (edge of the                 Install sufficient support for piping connected to the PHE.
       heat transfer plates).                                                                    A large piping load to the PHE may cause the frame to become deformed or
       Deformation of the heat transfer plate may cause damage to the plate gasket and           leakage.
       result in leakage.
       Do NOT allow debris or foreign material to get inside the PHE.                            Secure working space around the PHE.
       The clearance of the PHE is quite narrow, such that it can be easily clogged by           Installation and piping design must take into account the working space required for
       debris or foreign material. When flushing the piping, take measures such as               using disassembly and installation tools.
       installing a temporary strainer at the inlet piping or bypassing the PHE in order to
       prevent debris or foreign materials from entering the PHE.
                                                                                                 Clean the piping interior before connecting.
                                                                                                 Clean piping thoroughly so that no debris enters the PHE.
       Do NOT apply instantaneous negative pressure.                                             Ensure no pressure or fluid remaining inside before disassembling PHE
       Drawdown may occur if instantaneous negative pressure is applied to PHE by pump           and/or removing piping.
       stop or valve closing, or heat transfer plates deformation may also.                      Blowing out of PHE may cause severe injuries.
                                                                                                 Perform the thermometry of the cleaner at the point that temperature is the
                                                                                                 highest in including the heater exit.
                                                                                                 Harmful gas is generated when I surpass maximum temperature
                                                                                                 depending on the kind of the cleaner. In addition, it might adversely
                                                                                                 affect an equipment of the use when temperature rises.
                                                                                                                                                                                 P1
 2         What is the Plate-Clean Series?
       The Plate-Clean Series is designed for HISAKA PHE.
       By circulating Plate-Clean in the PHE, hard scale can be cleaned away coming from the cooling water / warm water and steam,
       without disassembling the heat exchanger unit.
      Three types are available, depending on the type of scales to be cleaned:
             1.   Plate-Clean C (For calcium)
             2.   Plate-Clean S (For silica, slime)
             3.   Plate-Clean F (For iron rust)
        [NOTE]
            Details such as the component of each cleaner in the Plate-Clean Series are indicated in the Safety Data Sheet (SDS)
            packed with the cleaner. Please check it before use.
 3         How to Use
 3-1       How to use Plate-Clean C
       Please follow the below steps for using the Plate-Clean C.
       ● Do not apply to silicon gasket.
           Gasket could be swelled.
       ● Use at the normal / room temperature.
           Harmful gas could be occurred by heated product.
       ● Provide sufficient ventilation
           Ventilate properly, especially when using in an underground room or pit.
       ● Wear personal protection.
           For safety reasons, wear goggles, a mask, and chemical-resistant gloves.
       ● Volume of cleaning liquid
           The volume of cleaning liquid should be 1.5 times the hold volume, or the hold volume plus 200 liters, whichever is less.
       ● Standard concentration
           The standard concentration should be 15wt%. Dissolve the cleaner (85 liters of water to 15 kilograms (approx. 12 liters) of
           the cleaner) to reach nearly standard concentration.
           Dissolution limit is 15wt%. Over 20wt%, part of the cleaner will not be dissolved and will remain to the bottom of the tank.
             * wt% (Concentration as % of weight)
       ● Operation time
           The standard operation time is 3 hours, and the maximum operation time is 12 hours.
           Foaming is possible depending on the scales.
3-2        How to use Plate-Clean S
       Please follow the below steps for using the Plate-Clean S.
       ● Do not apply to silicon gasket.
           Gasket could be swelled.
       ● Use at the normal / room temperature.
           Harmful gas could be occurred by heated product.
       ● Dilute Plate-Clean S with water in order to avoid heating. The concentration shall be less than below standard value.
       ● Provide sufficient ventilation.
           Ventilate properly, especially when using in an underground room or pit.
       ● Wear personal protection.
           For safety reasons, wear goggles, a mask, and chemical-resistant gloves.
       ● Volume of cleaning liquid
           The volume of cleaning liquid should be 1.5 times the hold volume, or the hold volume plus 200 liters, whichever is less.
P2
      ● Standard concentration
           The standard concentration should be 20wt%.
      ● Operation time
           At room temperature, standard operation time is 5 hours, and the maximum operation time is 12 hours.
           * Reaction may not occur immediately. Even if there is no reaction, carry out circulation cleaning for a minimum of 2 hours.
           * Foaming is possible depending on the scales.
3-3        How to use Plate-Clean F
      Please follow the below steps for using the Plate-Clean F
      ● Do not apply to nickel and copper alloy because it could be corroded by Plate-Clean F.
      ●    Maximum allowable working temperature
           The more temperature raise, the more washing effect.
           However, Do not use over 65 degree Celsius due to its maximum temperature.
      ● Prevent air intake
           During circulation, put the return piping which is inside of the tank into the lower level of liquid surface because air intake
           makes foam.
           *The undiluted solution is clear and colorless. However, when it reacts with metallic ions, it turns purple. As the reaction
           proceeds, the liquid becomes black and more viscous.
      ● Wear personal protection.
           For safety reasons, wear goggles, a mask, and chemical-resistant gloves.
      ● Cleaning liquid volume
           The volume of cleaning liquid should be 1.5 times the hold volume, or the hold volume plus 200 liters, whichever is less.
      ● Standard concentration
           The standard concentration should be 20w%.
      ● Standard Operation time
           Room temperature : 24 hours
           60℃ : 4 hours
4          Cleaning Procedure
      1.    Applicable equipment
           ①   Cleaning tank: Resin (Heat resistant temperature : Plate-Clean F operation temperature) or stainless steel
           ②   Cleaning pump: Resin (Heat resistant temperature : Plate-Clean F operation temperature) or stainless steel
               Flow rate: 100 liters/min, Pump head: Approx. 10 m
           ③   Electric heater (for Plate-Clean F only)
               Cleaning time could be reduced by using electric heater.
           ④   Chemical hoses: Approx. 40A (Chemical resistant against acid and alkalis, Heat resistant temperature : Plate-Clean F
                                       operating temperature)
           ⑤   Valves: Approx. 40A (Ball valves are recommended.)
           ⑥   Recovery tank: 200 liters (Chemical resistant material such as polyethylene lined is recommended)
           ⑦   Cleaner input port connection
           ⑧   Compressor (if 0.5MPa clean air is not available)
           * Do not apply to nickel and copper alloy because it could be corroded by Plate-Clean F.
      2.    Utilities to be prepared
           ①   Power source for the cleaning pump
           ②   Power source for the compressor, or 0.5 MPa clean air
           ③   Power source for the electric heater
           ④   Fresh water
                                                                                                                                      P3
     3.    Cleaning procedure (Refer to the flow sheet in Fig. 1.)
          ①   The cleaner will be sent from us after confirmation of condition of PHE and type of fluid and scales.
              Hisaka will inform the cleaning procedure such as cleaner type, concentration, time, and temperature.
          ②   Isolate the PHE from the fluid by using existing valves or close-off panel.
          ③   Drain fluid of PHE.
          ④   Connect the piping for cleaning. (Refer to Fig. 1 flow sheet.) The cleaner can be supplied and drained from the
              thermometer connection, pressure gauge connection, or drains. Please prepare a cleaner supply connection.
          ⑤   Dilute cleaner in cleaning tank and make it to the specified concentration.
              Read the Safety Data Sheet regarding for using cleaner.
          ⑥   Open valve V1, open V2, close V3, and open V4 to make the circulation route.
          ⑦   Start up the cleaning pump and supply cleaning fluid into PHE.
          ⑧   Use electric heater depending on the cleaner.
          ⑨   Carry out circulation cleaning as instructed. When cleaning is finished, turn off cleaning pump and close V1.
          ⑩   Connect air piping to part X of the cleaner return hose V4.
          ⑪   Put the hose through V3 into the collecting tank.
          ⑫   Close V1, open V2, open V3, and open V4.
          ⑬   Supply air from the top of the PHE and collect the used cleaner. Be careful to prevent cleaner from overflowing from the
              collecting tank.
              * Air pressure should be lower than the design pressure of PHE.
              * Keep the cleaner from blowing out and splashing.
          ⑭   After collection of cleaner, 1.Close V4 valve. 2. Shut off air supply. 3. Put washings return hose in a cleaning tank. 4.
              Check there is no residual air pressure.
          ⑮   PHE rinsing procedure is as follows. 1. Put fresh water in the cleaning tank. 2. Open valve V. 3. Close V3. 4. Turn on
              the cleaning pump and rinse the PHE. 5. When finish rinsing, stop the cleaning pump.
          ⑯   The rinse water shall be corrected after carrying out according ⑩ to ⑭.
          ⑰   If necessary, carry out circulation cleaning with a different type of cleaner.
          ⑱   Depending on the condition, neutralize the cleaner in the collecting tank.
          ⑲   Disassemble the piping.
          ⑳ Wash the cleaning tank, pump, and piping by fresh water and make sure there is no cleaner left.
                                                                  Fig.1-Flow Sheet
P4
5        Other Precautions
    ● Do not use the cleaner for anything other than its intended purpose and specification.
    ● If case of accidental ingestion of the cleaner, get medical advice.
    ● Stop usage of the product immediately, if you feel irritation in your eyes or throat, or if you feel ill during use. If you do not feel
        better, get medical advice.
    ● If the product comes in contact with your skin or clothing, wash it off with fresh water for 15 minutes or more. If you
        experience any irregularities, get medical advice.
6        Inquiries
    Contact info for inquiries
         HISAKA WORKS, LTD., Heat Exchanger Div., Sales Department
            Osaka: 2-1-48, Higashi-Konoike-cho, Higashi-Osaka, Osaka, 578-0973, Japan                        Tel : +81-(0)72-966-9601
                                                                                                             Fax : +81-(0)72-966-8923
            Tokyo: KYOBASHI OM BLDG. 1-19-8, Kyobashi, Chuo-Ku, Tokyo, 104-0031, Japan                       Tel : +81-(0)3-5250-0760
                                                                                                             Fax : +81-(0)3-3562-2759
            Nagoya: Fujifilm Nagoya Bldg. 12th Floor, 1-12-17, Sakae, Naka-Ku, Nagoya,                       Tel : +81-(0)52-217-2491
                       Aichi 460-0008, Japan                                                                 Fax : +81-(0)52-217-2494
            URL : http://www.hisaka.co.jp/english/
    Global Network
       HisakaWorks S.E.A. Sdn. Bhd. (MALAYSIA)
            No.2, Jalan TP2. Taman Perindustrian SIME UEP, 47600 Subang Jaya, Selangor                       Tel : +603-8081-4185
            E-mail : heatexc@hisaka-asia.com                                                                 Fax : +603-80817185
       HisakaWorks S.E.A. Sdn. Bhd. PENANG BRANCH (MALAYSIA)
            No 2680, 2nd Floor, Jalan Chain Ferry, Taman Inderawasih, 13600 Perai, Penang,                   Tel : +60-16-203-2527
            Malaysia
                                                                                                             Fax : +60-4-390-8588
            E-mail : cyyap@hisaka-asia.com
       HisakaWorks S.E.A. Sdn. Bhd. JOHOR BRANCH (MALAYSIA)
            30-02, JalanMolek 1/10, Taman Molek, 81100 Johor Bahru Malaysia                                  Tel : +60-12-227-4882
                                                                                                             Fax : +60-7-351-6840
            E-mail : cswong@hisaka-asia.com
       Hisaka Works (Thailand) Co., Ltd. (THAILAND)
            15th Floor, Phairoj Kijja Tower, Zone C, 825 Bangna-Trad Road, Kwang Bangna, Khet                Tel : +66-2-744-3287
            Bangna, Bangkok 10260, Thailand
            E-mail : heatexc@hisaka-thai.com                                                                 Fax : +66-2-744-3286
       Hisaka Works (Thailand) Co., Ltd. RAYONG SERVICE CENTER (THAILAND)
            300/118, Moo1, Tambol Tasit, Amphoe Pluakdaeng, Rayong 21140, Thailand                           Tel : +66-3-802-9532
            E-mail : heatexc@hisaka-thai.com                                                                 Fax : +66-3-802-9530
       Hisaka Works (Singapore) Pte Ltd. (SINGAPORE)
            No.18, Boon Lay Way, #02-118, Trade Hub 21 Singapre 609966                                       Tel : +65-6897-8489
            E-mail : heatex@hisaka-sing.com                                                                  Fax : +65-6686-4579
                                                                                                                                         P5
      PT.HISAKA WORKS INDONESIA (INDONESIA)
        RukoPuri Botanical, Jln. Joglo Raya Blok I 10/29, Kebun Jeruk, Jakarta Barat 11640,      Tel : +62-21-5890-0090
        Indonesia
        E-mail : hisakindo@hisaka-asia.com                                                       Fax : +62-21-5890-0091
     Hisapino (Hisakaworks S.E.A. Philippines Sales Representative Office) (PHILIPPINES)
        20th Floor, One Global Place, Office Business Center, 5th Avenue & 25th Street,          Tel : +63-2-224-4129
        Bonifacio Global City, Taguig 1632, Philippines                                          Fax : +63-2-224-4130
        E-mail : hisapino@hisaka-asia.com
     Hisavina (Hisakaworks S.E.A. Vietnam Sales Representative Office) Ho Chi Minh Representative
     Office (VIETNAM)
        4th Floor, Hoang Dan Building, 47-49, Hoang Sa Street, Da Kao Ward, District 1, Ho Chi   Tel : +84 (8) 3910 7355
        Minh City, Vietnam                                                                       Fax : +84 (8) 39107356
        E-mail : hisavina@hisaka-asia.com
     Hisavina (Hisakaworks S.E.A. Vietnam Sales Representative Office) Hanoi Representative Office
     (VIETNAM)
        8th Floor, Sannam Building, Duy Tan Street, Dich Vong Hau Ward, Cau Giay District,       Tel : +84-4-3795-9900
        Hanoi, Vietnam                                                                           Fax : +84-4-3795-9911
     Hisaka Works (China) Co., Ltd. (CHINA)
        No.1 Xiangyuan Road, Changshu Southeast Economic Development Zone,                       Tel : +86-512-5213-3000
        Changshu City, Jiangsu Province 215542, China                                            Fax : +86-512-5213-3008
     Hisaka Works (China) Co., Ltd. Shanghai Branch                 (CHINA)
        Room 1603 Shanghai Orientalcenter, 699 West Nanjin Road,                                 Tel : +86-21-5211-0701
        Shanghai 200041, China                                                                   Fax : +86-21-5211-0720
        E-mail : hisaka-sha@hisaka.co.jp
     Hisaka (China) Co., Ltd. Guangzhou Branch                (CHINA)
        Room 1208 R&F Tianhe Commercial Bldg., 4 Huanting Rd. Tianhe,                            Tel : +86-20-3810-5515
        Guangzhou, Guangdong, China                                                              Fax : +86-20-3847-7539
     Hisaka Middle East Co., Ltd.
        P.O. Box 8221, 5017 King Saud Rd, Al-Hosan Bldg. 5th floor, Dammam 31482, Kingdom        Tel : +966-3-8331473
        of Saudi Arabia                                                                          Fax : +966-3-8331471
        Email : info@hisaka-me.com
        URL : www.hisaka-me.com
     Hisaka Korea Co., Ltd.
        Gwanghwamun Bldg. 15F, 149 Sejong-daero, Jongno-gu, Seoul, 110-730, Korea                Tel : +82-(0)2-739-8861~3
        Email : heatexc@hisakakorea.com                                                          Fax : +82-(0)2-739-8864
      Hisaka Korea Co., Ltd. BUSAN BRANCH
        13th Floor, Kyowon Building, 216 Jungang-daero, Dong-gu, Busan 48733, South Korea        Tel : +82-51-747-0265
                                                                                                 Fax : +82-51-747-0266
P6
     [NOTE]
          Please inform us the "MFG. Number" and "Model" described on the nameplate or Plate Arrangement Drawing
           and Assembly Drawing.
   For more information
    Hisaka Works, Ltd. official homepage (http://www.hisaka.co.jp/english/).
   Customer's memo
    Please fill in the table below with PHE information.
      Item Number
     MFG. Number
          Model
            Qty
         Date MFG.
      Maintenance
        records
          Memo
                                                                                                                    P7
Hisaka Works, Ltd., Heat Exchanger Division acquires both ISO9001 and ISO14001 certification.
                                                                                         HE-ME003600R2