LED Sign Storm Tube
LED Sign Storm Tube
Hanging Installation
The SignStorm Sign tube from Beyond LED Technology is one of the most energy efficient product of 2021
which offers a very long lifespan, as they are designed primarily to substitute the fluorescent lamps.
SignStorm lamps are available with a Type B ballast bypass design that offers easy installation and
operation. In addition, these sign tube can be used with hard-wiring tombstone lamp-holders that can be
connected directly to incoming AC power leads. Dual-ended bypass lamps eliminate the need to replace
shunted tombstone lamp-holders in existing fluorescent luminaires, while maintaining a high Lumen
output and up to 125 lumens per watt efficacy. AC power code is also provided for new installation.
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
Specifications
Product Features
• Operating temperature: -20°C to 45°C
• Lockable and Rotatable R17d end cap ensures easy installation and consistent light distribution
• Integral LED driver (non-isolated), eliminates the need for an external driver or ballast
• ETL listed
• Option of making virtually any size by combining two parts of the product in one tube
• Non flicker, optical lens covers eliminate hot spots and ensure consistent light distribution
• Aluminium + PC lamp housing ensures less breakage and good heat dissipation
SKU
Component Name Specification Image
Number
Transparent Butt
Transparent Butt Joint 152735
Joint
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU No. 152727 Specifications
Input Power 3W
CRI >80
Diffuser Type Clear
Beam Angle 180°
IP Rating IP44
Warranty Time 5 Years
CRI >80
Diffuser Type Clear
Beam Angle 180°
IP Rating IP44
Warranty Time 5 Years
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU No. 152729 Specifications
CRI >80
Diffuser Type Clear
Beam Angle 180°
IP Rating IP44
Warranty Time 5 Years
CRI >80
Diffuser Type Clear
Beam Angle 180°
IP Rating IP44
Warranty Time 5 Years
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU No. 152731 Specifications
Input Power 6W
CRI >80
Diffuser Type Clear
Beam Angle 360°
IP Rating IP44
Warranty Time 5 Years
Input Power 9W
CRI >80
Diffuser Type Clear
Beam Angle 360°
IP Rating IP44
Warranty Time 5 Years
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU No. 152733 Specifications
CRI >80
Diffuser Type Clear
Beam Angle 360°
IP Rating IP44
Warranty Time 5 Years
CRI >80
Diffuser Type Clear
Beam Angle 360°
IP Rating IP44
Warranty Time 5 Years
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
Correlated Color Temperature (CCT)
Dimensions
The units covered by this report were intended to retrofit surface mount with diffuser for these models,
Type IC or non-IC recessed mount listed fluorescent luminaires that use maximum two tubular lamps, the
minimum lamp compartment dimensions are tabulated below:
MIN. distance
MAX.
SKU between tubes
Model Interconnected
Number installation lighting
Unit
sign(inches)
152734 BLT-ST842-21W-360-65K
3.94 20
152730 BLT-ST842-10.5W-180-65K
152733 BLT-ST830-15W-360-65K
3.94 20
152729 BLT-ST830-7.5W-180-65K
152732 BLT-ST818-9W-360-65K
3.94 20
152728 BLT-ST818-4.5W-180-65K
152731 BLT-ST812-6W-360-65K
3.94 20
152727 BLT-ST812-3W-180-65K
Double Sided
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU number 152727 Light Distribution Testing Parameters
Luminaire Data
Photometric Results
Luminaire Data
Photometric Results
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU number 152729 Light Distribution Testing Parameters
Luminaire Data
Photometric Results
Luminaire Data
Photometric Results
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU number 152731 Light Distribution Testing Parameters
Luminaire Data
Photometric Results
Luminaire Data
Photometric Results
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
SKU number 152733 Light Distribution Testing Parameters
Luminaire Data
Photometric Results
Luminaire Data
Photometric Results
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
Notes Before Installation
Caution
Installation Instructions
3. WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of sign
electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
4. WARNING – Risk of fire or electric shock. Install this kit only in host signs that have been identified in
the installation instructions and where the input rating of the retrofit kit does not exceed the input rating
of the sign.
5. WARNING – Risk of fire or electric shock. Installation of this LED retrofit kit may involve drilling or
punching of holes into the structure of the sign. Check for enclosed wiring and components to avoid
damage to wiring and electrical parts.
6. Installer should examine all parts that are not intended to be replaced by the retrofit kit for damage
and replace any damaged parts prior to installation of the retrofit kit.
7. Installers should not disconnect existing wires from lamp holder terminals to make new connections at
lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder
and make new electrical connections to lamp holder lead wires by employing applicable connectors.
8. Repair and seal any unused openings in the electrical enclosure. Openings greater than 0.5 inches
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller
openings may be sealed with non-hardening caulk.
9. WARNING: To avoid potential fire or shock hazard, do not use this retrofit kit with existing shunted bi-
pin lamp holders in the host sign. Note: Shunted lamp holders are found only in fluorescent signs with
Instant-Start ballasts. Instant-start ballasts can be identified by the words "Instant Start" or "I.S." marked
on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may
be combined with the marking for the lamps with which the ballast is intended to be used.
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
INSTALLATION GUIDE
Disconnect power to luminaire or circuit (if possible). Ensure all power is off by using a voltmeter or other
method to confirm.
3. FIXTURE REWIRING
a. R17d lamp holder installation, please rewiring the fixture according to the below diagram.
a. Please check the length of the original fluorescent tube, and then select the right components accordingly.
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
e. Replace troffer lens, if present.
f. After modification completed. Attach the Replacement Marking and cautionary Label to a visible place
on the luminaire and keep it visible after installation.
a. Fix the hanging chain to hanging connectors on the splicing part and end caps of the lamp, and hang up
with chains one to one between connectors, as shown below.
b. Read label on the lamp on the bottom to ensure the power end of LED. Use connector cord to link the
other end to the end of above lamp. Make sure the power of each circuit is not higher than 550W.
c. Read label on the lamp on the bottom to ensure the power end of LED. Insert the power cord to the
powered each end of the bottom lamp.
d. Connect the power cords together to AC input wire
e. LED lamps are now fully installed.
f. Replace troffer lens, if present.
g. After modification completed. Attach the Replacement Marking and cautionary Label to a visible place
on the luminaire and keep it visible after installation.
Trouble Shooting
Packaging
BLT-ST842-21W-360-
152734 46.8 x 7.5 x 8.07 28.66
65K
BLT-ST830-15W-360-
152733 34.8 x 7.5 x 8.07 21.38
65K
BLT-ST818-9W-360-
152732 22.83 x 7.52 x 8.07 12.79
65K
BLT-ST812-6W-360-
152731 16.93 x 7.52 x 8.07 10.14
65K
BLT-ST842-10.5W-
152730 46.8 x 7.5 x 8.07 26.01
180-65K
BLT-ST830-7.5W-180-
152729 34.8 x 7.5 x 8.07 19.18
65K
BLT-ST818-4.5W-180-
152728 22.83 x 7.52 x 8.07 12.57
65K
BLT-ST812-3W-180-
152727 16.93 x 7.52 x 8.07 9.48
65K
Application
Widely used in supermarket, warehouse, garage, home, office, hotel, hospital, school etc.
Beyond LED Technology | 1939 Parker Ct, Stone Mountain, GA, 30087
Due to continuous product improvement, information in this document is subject to change.
Safety Precautions
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts,
cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box
and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
precautions.
Commercial installation, service and maintenance of luminaires should be performed by a qualified
licensed electrician.
For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a
qualified licensed electrician and check your local electrical code.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp
objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit
installation.
Warranty
5 Years Warranty