0% found this document useful (0 votes)
253 views6 pages

Iscan80 Brochure

iScan80, the high-speed 80kHz OCT that sets the standard for efficiency - perfect for ECPs seeking an affordable and versatile OCT system. It’s ideal for practices with limited staff since iScan80 delivers consistent scan acquisition with minimal training and vocally guides patients through an entire exam in any of 12 languages.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
253 views6 pages

Iscan80 Brochure

iScan80, the high-speed 80kHz OCT that sets the standard for efficiency - perfect for ECPs seeking an affordable and versatile OCT system. It’s ideal for practices with limited staff since iScan80 delivers consistent scan acquisition with minimal training and vocally guides patients through an entire exam in any of 12 languages.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

iScan80 Comprehensive

3d Retina 12mm Radial Scan

Our vision is foresight

Our vision is foresight


Retinal analysis and 3D imaging Enhanced Depth
Retinal imaging capabilities include retina Since 2006, Optovue has been a leading provider of
12mm widefield scan with enhanced depth
mapping with normative comparison and imaging mode provides high resolution views. OCT technology for ocular diagnostic imaging, having
a 3D retina scan with en face presentation, which installed more than 15,000 systems on six continents.
enables virtual retinal dissection by displaying
Optovue is focused on furthering the science, efficacy and
three different reference planes: ILM, IPL and RPE. Anterior Segment Angle With Measurement
clinical application of OCT for enhanced eye health, and
continuing to build upon our history of OCT patents and firsts.
3d Optic Disc Scan Not surprisingly, this specialization has yielded a history of OCT patents and firsts.

Our mission is your success


Pachymetry Map To unleash the full potential of OCT in your practice, Optovue puts its comprehensive OCT resource center at your disposal:
•T
 he Academy at Optovue brings OCT education to your computer and mobile screens to help you interpret images,
understand reports, apply the information to clinical practice—or help your staff become better OCT operators.
• Training and Support starts with professional installation and in-office staff training from your dedicated
Optovue clinical applications specialist and goes on to include five years of free phone and online support.
Additional capabilities
•F
 ree Software Updates that improve system usability and efficiency throughout your instrument’s operational lifetime
In-depth 3D optic disc analysis
All iScan80 systems feature Optovue’s exclusive are included with every iScan80 system. Major software upgrades may be available for purchase.
GCC analysis helps identify ganglion cell loss, iWellnessExam. iScan80 Comprehensive includes
which sometimes precedes RNFL loss. 3D disc Cornea Advance anterior segment imaging features Bottom line, when you invest in iScan80, you also secure a valuable OCT practice partner.
scan depicts the optic nerve in cross section with such as pachymetry mapping and a variety of
the representative thicknesses of selected slices. corneal and angle measurement tools.
Put Optovue foresight to work in your practice today
For a complimentary practice consultation or iSeries system demonstration call 1.510.623.8868 or visit optovue.com.

iScan80 specifications

Scanner OCT Fundus Image (En Face)


OCT Image 80,000 A-scan/second FOV (H) 21° x (V) 21°
Depth Resolution (in tissue) 5.0 μm Minimum Pupil Diameter 2.0mm
Our vision is foresight
Transverse Resolution 15 μm (retina) External Image (Live IR) FOV 13mm x 8mm

2800 Bayview Drive, Fremont, CA 94538 optovue.com


Scan Range Size OCT System
Depth 2 - 2.3mm (retina) Dimensions (in.) (W) 19.81 x (L) 15.83 x (H) 17.82
© 2021 Optovue, Inc. iScan80, GCC and IWellnessExam are registered trademarks of Optovue, Inc. All rights reserved.
Scan Beam Wavelength 840nm (+/-10nm) Weight (lb.) 42.94
1. Data on file.
300-52534 Rev. C
iScan80 ® OCT iWellness OCT iWellness Benefits Patients
The OCT iWellness program benefits patients by helping them

The OCT that practically runs itself The OCT iWellness scan is an Optovue exclusive that uses quick, easy OCT scan to promote better overall patient eye health.
become more involved in their own eye health. The scanning process
is simple and quick, and each patient receives
Its utility stems from a single, comprehensive report that shows:
comprehensive, personalized eye health
Introducing the next-generation iScan—where advanced scanning is realized in a system so information in an easy-to-understand report.
• Retinal thickness and GCC thickness with normative comparison
user-friendly it even talks to patients. Meet iScan80 ® , the high-speed 80kHz OCT that sets the
standard for efficiency—perfect for ECPs seeking an affordable and versatile OCT system. It’s ideal for • Symmetry analysis
practices with limited staff since iScan80 delivers consistent scan acquisition with minimal training—and • FLV% and GLV%, proprietary Optovue GCC metrics that provide important information to aid in glaucoma OCT iWellness Benefits Eye
vocally guides patients through an entire exam in any of 12 languages. The new iScan80 delivers the following diagnosis and management
advancements:
Care Providers
• Eight high-resolution B-scans OCT iWellness benefits ECPs by providing
• 80,000 A-scans per second – 3x faster than the original iScan OCT a valuable assessment tool that can reveal
the need for more extensive imaging. It also
• Simplified scan acquisition
streamlines the exam process by quickly
• New reports and wider field of view confirming normal—or helping you more
efficiently diagnose pathology. Optovue’s
Compact and portable, iScan80's streamlined design integrates the operator interface, display, patient interface and
current iWellness users have affirmed that the
scan head into one console that can be moved from station to station and mounted on any tabletop. Then comes the
OCT iWellness scan improves patient involvement, loyalty and retention.
easy part—plug in, switch on and start scanning.
This helps you grow and differentiate your eye care practice, while also
providing a new revenue stream.
iScan80 Comprehensive Capabilities

iScan80 Comprehensive includes:


GCC map can
• OCT iWellness scan reveal
Retinal thickness map
GCC thinning Networking solutions
• Retina mapping uncovers thinning and
thickening iScan80 provides comprehensive networking capabilities for the most effective and efficient OCT utilization. It stems
• RFNL and GCC trend ®
from our NetVue product suite, which empowers you to receive, review and modify images wherever and whenever
analyses you choose. Capture new patient scans while existing scans are being reviewed. View and modify images from as
many as 10 review stations. Access OCT images from your smart phone, tablet, laptop or desktop. NetVue makes
• FLV% and GLV% analysis to
such seamless workflow possible. Naturally iScan80 is fully DICOM compatible.
increase GCC sensitivity and
specificity
Review station requirements
• High-density 3D retinal
imaging
Operating System: Win 10, 64 bit
• In-depth 3D optic nerve head Processor Speed: Intel® Celeron (i7-8700T 2.40 GHz)
ETDRS diagram shows average Optovue’s exclusive FLV% and GLV% Computer RAM: 16 GB or higher
analysis retinal thickness by zone as compared provide valuable data points to aid in Network Bandwidth: 1Gbps or higher
to the normative database the prediction of visual field conversion
• Cornea Advance anterior segment Monitor Resolution: 24 in.1920x1080 60Hz
in glaucoma suspects1
imaging and measurement
iScan80 Comprehensive

3d Retina 12mm Radial Scan

Our vision is foresight

Our vision is foresight


Retinal analysis and 3D imaging Enhanced Depth
Retinal imaging capabilities include retina Since 2006, Optovue has been a leading provider of
12mm widefield scan with enhanced depth
mapping with normative comparison and imaging mode provides high resolution views. OCT technology for ocular diagnostic imaging, having
a 3D retina scan with en face presentation, which installed more than 15,000 systems on six continents.
enables virtual retinal dissection by displaying
Optovue is focused on furthering the science, efficacy and
three different reference planes: ILM, IPL and RPE. Anterior Segment Angle With Measurement
clinical application of OCT for enhanced eye health, and
continuing to build upon our history of OCT patents and firsts.
3d Optic Disc Scan Not surprisingly, this specialization has yielded a history of OCT patents and firsts.

Our mission is your success


Pachymetry Map To unleash the full potential of OCT in your practice, Optovue puts its comprehensive OCT resource center at your disposal:
•T
 he Academy at Optovue brings OCT education to your computer and mobile screens to help you interpret images,
understand reports, apply the information to clinical practice—or help your staff become better OCT operators.
• Training and Support starts with professional installation and in-office staff training from your dedicated
Optovue clinical applications specialist and goes on to include five years of free phone and online support.
Additional capabilities
•F
 ree Software Updates that improve system usability and efficiency throughout your instrument’s operational lifetime
In-depth 3D optic disc analysis
All iScan80 systems feature Optovue’s exclusive are included with every iScan80 system. Major software upgrades may be available for purchase.
GCC analysis helps identify ganglion cell loss, iWellnessExam. iScan80 Comprehensive includes
which sometimes precedes RNFL loss. 3D disc Cornea Advance anterior segment imaging features Bottom line, when you invest in iScan80, you also secure a valuable OCT practice partner.
scan depicts the optic nerve in cross section with such as pachymetry mapping and a variety of
the representative thicknesses of selected slices. corneal and angle measurement tools.
Put Optovue foresight to work in your practice today
For a complimentary practice consultation or iSeries system demonstration call 1.510.623.8868 or visit optovue.com.

iScan80 specifications

Scanner OCT Fundus Image (En Face)


OCT Image 80,000 A-scan/second FOV (H) 21° x (V) 21°
Depth Resolution (in tissue) 5.0 μm Minimum Pupil Diameter 2.0mm
Our vision is foresight
Transverse Resolution 15 μm (retina) External Image (Live IR) FOV 13mm x 8mm

2800 Bayview Drive, Fremont, CA 94538 optovue.com


Scan Range Size OCT System
Depth 2 - 2.3mm (retina) Dimensions (in.) (W) 19.81 x (L) 15.83 x (H) 17.82
© 2021 Optovue, Inc. iScan80, GCC and IWellnessExam are registered trademarks of Optovue, Inc. All rights reserved.
Scan Beam Wavelength 840nm (+/-10nm) Weight (lb.) 42.94
1. Data on file.
300-52534 Rev. C
iScan80 ® OCT iWellness OCT iWellness Benefits Patients
The OCT iWellness program benefits patients by helping them

The OCT that practically runs itself The OCT iWellness scan is an Optovue exclusive that uses quick, easy OCT scan to promote better overall patient eye health.
become more involved in their own eye health. The scanning process
is simple and quick, and each patient receives
Its utility stems from a single, comprehensive report that shows:
comprehensive, personalized eye health
Introducing the next-generation iScan—where advanced scanning is realized in a system so information in an easy-to-understand report.
• Retinal thickness and GCC thickness with normative comparison
user-friendly it even talks to patients. Meet iScan80 ® , the high-speed 80kHz OCT that sets the
standard for efficiency—perfect for ECPs seeking an affordable and versatile OCT system. It’s ideal for • Symmetry analysis
practices with limited staff since iScan80 delivers consistent scan acquisition with minimal training—and • FLV% and GLV%, proprietary Optovue GCC metrics that provide important information to aid in glaucoma OCT iWellness Benefits Eye
vocally guides patients through an entire exam in any of 12 languages. The new iScan80 delivers the following diagnosis and management
advancements:
Care Providers
• Eight high-resolution B-scans OCT iWellness benefits ECPs by providing
• 80,000 A-scans per second – 3x faster than the original iScan OCT a valuable assessment tool that can reveal
the need for more extensive imaging. It also
• Simplified scan acquisition
streamlines the exam process by quickly
• New reports and wider field of view confirming normal—or helping you more
efficiently diagnose pathology. Optovue’s
Compact and portable, iScan80's streamlined design integrates the operator interface, display, patient interface and
current iWellness users have affirmed that the
scan head into one console that can be moved from station to station and mounted on any tabletop. Then comes the
OCT iWellness scan improves patient involvement, loyalty and retention.
easy part—plug in, switch on and start scanning.
This helps you grow and differentiate your eye care practice, while also
providing a new revenue stream.
iScan80 Comprehensive Capabilities

iScan80 Comprehensive includes:


GCC map can
• OCT iWellness scan reveal
Retinal thickness map
GCC thinning Networking solutions
• Retina mapping uncovers thinning and
thickening iScan80 provides comprehensive networking capabilities for the most effective and efficient OCT utilization. It stems
• RFNL and GCC trend ®
from our NetVue product suite, which empowers you to receive, review and modify images wherever and whenever
analyses you choose. Capture new patient scans while existing scans are being reviewed. View and modify images from as
many as 10 review stations. Access OCT images from your smart phone, tablet, laptop or desktop. NetVue makes
• FLV% and GLV% analysis to
such seamless workflow possible. Naturally iScan80 is fully DICOM compatible.
increase GCC sensitivity and
specificity
Review station requirements
• High-density 3D retinal
imaging
Operating System: Win 10, 64 bit
• In-depth 3D optic nerve head Processor Speed: Intel® Celeron (i7-8700T 2.40 GHz)
ETDRS diagram shows average Optovue’s exclusive FLV% and GLV% Computer RAM: 16 GB or higher
analysis retinal thickness by zone as compared provide valuable data points to aid in Network Bandwidth: 1Gbps or higher
to the normative database the prediction of visual field conversion
• Cornea Advance anterior segment Monitor Resolution: 24 in.1920x1080 60Hz
in glaucoma suspects1
imaging and measurement
iScan80 ® OCT iWellness OCT iWellness Benefits Patients
The OCT iWellness program benefits patients by helping them

The OCT that practically runs itself The OCT iWellness scan is an Optovue exclusive that uses quick, easy OCT scan to promote better overall patient eye health.
become more involved in their own eye health. The scanning process
is simple and quick, and each patient receives
Its utility stems from a single, comprehensive report that shows:
comprehensive, personalized eye health
Introducing the next-generation iScan—where advanced scanning is realized in a system so information in an easy-to-understand report.
• Retinal thickness and GCC thickness with normative comparison
user-friendly it even talks to patients. Meet iScan80 ® , the high-speed 80kHz OCT that sets the
standard for efficiency—perfect for ECPs seeking an affordable and versatile OCT system. It’s ideal for • Symmetry analysis
practices with limited staff since iScan80 delivers consistent scan acquisition with minimal training—and • FLV% and GLV%, proprietary Optovue GCC metrics that provide important information to aid in glaucoma OCT iWellness Benefits Eye
vocally guides patients through an entire exam in any of 12 languages. The new iScan80 delivers the following diagnosis and management
advancements:
Care Providers
• Eight high-resolution B-scans OCT iWellness benefits ECPs by providing
• 80,000 A-scans per second – 3x faster than the original iScan OCT a valuable assessment tool that can reveal
the need for more extensive imaging. It also
• Simplified scan acquisition
streamlines the exam process by quickly
• New reports and wider field of view confirming normal—or helping you more
efficiently diagnose pathology. Optovue’s
Compact and portable, iScan80's streamlined design integrates the operator interface, display, patient interface and
current iWellness users have affirmed that the
scan head into one console that can be moved from station to station and mounted on any tabletop. Then comes the
OCT iWellness scan improves patient involvement, loyalty and retention.
easy part—plug in, switch on and start scanning.
This helps you grow and differentiate your eye care practice, while also
providing a new revenue stream.
iScan80 Comprehensive Capabilities

iScan80 Comprehensive includes:


GCC map can
• OCT iWellness scan reveal
Retinal thickness map
GCC thinning Networking solutions
• Retina mapping uncovers thinning and
thickening iScan80 provides comprehensive networking capabilities for the most effective and efficient OCT utilization. It stems
• RFNL and GCC trend ®
from our NetVue product suite, which empowers you to receive, review and modify images wherever and whenever
analyses you choose. Capture new patient scans while existing scans are being reviewed. View and modify images from as
many as 10 review stations. Access OCT images from your smart phone, tablet, laptop or desktop. NetVue makes
• FLV% and GLV% analysis to
such seamless workflow possible. Naturally iScan80 is fully DICOM compatible.
increase GCC sensitivity and
specificity
Review station requirements
• High-density 3D retinal
imaging
Operating System: Win 10, 64 bit
• In-depth 3D optic nerve head Processor Speed: Intel® Celeron (i7-8700T 2.40 GHz)
ETDRS diagram shows average Optovue’s exclusive FLV% and GLV% Computer RAM: 16 GB or higher
analysis retinal thickness by zone as compared provide valuable data points to aid in Network Bandwidth: 1Gbps or higher
to the normative database the prediction of visual field conversion
• Cornea Advance anterior segment Monitor Resolution: 24 in.1920x1080 60Hz
in glaucoma suspects1
imaging and measurement
iScan80 Comprehensive

3d Retina 12mm Radial Scan

Our vision is foresight

Our vision is foresight


Retinal analysis and 3D imaging Enhanced Depth
Retinal imaging capabilities include retina Since 2006, Optovue has been a leading provider of
12mm widefield scan with enhanced depth
mapping with normative comparison and imaging mode provides high resolution views. OCT technology for ocular diagnostic imaging, having
a 3D retina scan with en face presentation, which installed more than 15,000 systems on six continents.
enables virtual retinal dissection by displaying
Optovue is focused on furthering the science, efficacy and
three different reference planes: ILM, IPL and RPE. Anterior Segment Angle With Measurement
clinical application of OCT for enhanced eye health, and
continuing to build upon our history of OCT patents and firsts.
3d Optic Disc Scan Not surprisingly, this specialization has yielded a history of OCT patents and firsts.

Our mission is your success


Pachymetry Map To unleash the full potential of OCT in your practice, Optovue puts its comprehensive OCT resource center at your disposal:
•T
 he Academy at Optovue brings OCT education to your computer and mobile screens to help you interpret images,
understand reports, apply the information to clinical practice—or help your staff become better OCT operators.
• Training and Support starts with professional installation and in-office staff training from your dedicated
Optovue clinical applications specialist and goes on to include five years of free phone and online support.
Additional capabilities
•F
 ree Software Updates that improve system usability and efficiency throughout your instrument’s operational lifetime
In-depth 3D optic disc analysis
All iScan80 systems feature Optovue’s exclusive are included with every iScan80 system. Major software upgrades may be available for purchase.
GCC analysis helps identify ganglion cell loss, iWellnessExam. iScan80 Comprehensive includes
which sometimes precedes RNFL loss. 3D disc Cornea Advance anterior segment imaging features Bottom line, when you invest in iScan80, you also secure a valuable OCT practice partner.
scan depicts the optic nerve in cross section with such as pachymetry mapping and a variety of
the representative thicknesses of selected slices. corneal and angle measurement tools.
Put Optovue foresight to work in your practice today
For a complimentary practice consultation or iSeries system demonstration call 1.510.623.8868 or visit optovue.com.

iScan80 specifications

Scanner OCT Fundus Image (En Face)


OCT Image 80,000 A-scan/second FOV (H) 21° x (V) 21°
Depth Resolution (in tissue) 5.0 μm Minimum Pupil Diameter 2.0mm
Our vision is foresight
Transverse Resolution 15 μm (retina) External Image (Live IR) FOV 13mm x 8mm

2800 Bayview Drive, Fremont, CA 94538 optovue.com


Scan Range Size OCT System
Depth 2 - 2.3mm (retina) Dimensions (in.) (W) 19.81 x (L) 15.83 x (H) 17.82
© 2021 Optovue, Inc. iScan80, GCC and IWellnessExam are registered trademarks of Optovue, Inc. All rights reserved.
Scan Beam Wavelength 840nm (+/-10nm) Weight (lb.) 42.94