AXE      4 DIGITAL(ONE-ALARM) & 6 DIGITAL TOTALIZER Counter (72x72mm)                                                 MCT726 series
FEATURES
 Accept more type sensors(switch, encoder, proximity switch            Totalizer counting mode can be modified (synchronize or
 ,…etc)finish length/flow control                                      un-sychronnize)
 Accept input rates up to 10KHz                                        N,R,C alarm control mode
 Readout range (0~9999),Totalize range(0~999999)                       0.36” & 0.28”LED highlight display
 Alarm output action times 0~99.9sec can be modified                   Man-machine interface, easy to operate
 Power down saving                                                     EEPROM Saving, data safekeeping about 10 years
 Decimal point can be modified                                         Modified inside parameter, must have pass code
 Input scaling multiplied 0.001 to 9.999 can be modified
Name of Parts
                                                                           TV               Totalize value display
                                       OUT1 OUT2
                                                                           PV              Counter value display
                                                                           SV              Setting value display
                                                                           AL
                                 ENT                                       SET
Function keys                                                                                 Function keys
                                 TRST                                      PRST
                                           4       3     2         1
                                                                                          Perdigit setting keys
  Connect Diagram
 Contact input (PNP)                           CMOS input (12V OR 15V)                        Sensor input (PNP 12V)
          IN                                                 IN                                          IN
          12V        Inside jumper                           12V        Inside jumper          Sensor   12V        Inside jumper
                     1   2   3   4                                     1    2     3   4                            1     2   3   4
                                                                       OFF ON OFF OFF                   COM       OFF ON OFF OFF
         COM        OFF ON ON OFF                  GND   COM
 Contact inpu (NPN)                            TTL input (5V)                                 Sensor inpu (NPN 12V)
          IN                                                 IN                                          IN
          12V        Inside jumper                           12V        Inside jumper          Sensor   12V        Inside jumper
                     1   2   3   4                                     1    2     3   4                            1     2   3   4
                    ON OFF ON OFF                  GND   COM           OFF ON OFF ON                    COM        ON OFF OFF OFF
         COM
Alarm output control description
N(MANUAL): When count value equal setting value the relay ON & continue count until reset by panel or connect terminal then relay
OFF & count value return to RST setting value
R(RETURN): When count value equal setting value the relay ON & continue count until relay action time out then relay OFF & count
value return to RST setting value
C(CONTINUE): When count value equal setting value the relay ON & count value return to RST setting value then continue
count & relay action time out the relay OFF
 N/R/C control mode is one-alarm,N control mode is totalizer
 MODE: SYN(one-alarm count and totalizer count is synchronize counting)
      :NSYN(one-alarm count alarm once,totalize count on the increase)
      Key Introduce                                              Operation Manual
  Key Function         1. In normal display, The key function is call out setting group
                       2. In parameter setting page, The key function is data Enter , and go to next page
PRST Key Function      1.The key function is one-alarm count value return zero and realy OFF
TRST Key Function      1The key function is totalizer count value return zero and realy Off
AL SET Key Function 1. In normal display, The key function is call out totalizer alarm value
Per digital & key      1.In normal display according to alarm indicate press per digit / setting per alarm value
Function               2.Into parameter setting page,If need modify data can press per digit / key Into setting
                           procedure,The parameter data will increment/decrement (key response about 0.2 sec)
Digital 1 & key        In setting page press digit 1 & key return normal display,but if in setting
Function               Page the modify data will lost
No Key in anything     In setting group or setting page no key in anything about 2 minutes, return normal display
 Step Parameter mark description Parameter mark                                  Operation manual
  1     Normal display                                Press   /FUNC   key  into P.COD   setting page
  2     P.COD(Pass code input page)                    1. Key in 4 digit pass code with & & key
        Default=0                                      2. Press key, the pass code is right into setting group , otherwise
                                                        return normal display
        MODE(Count Mode)                               1.Decide the totalize count mode with 1 or key(SYN,NSYN)
  3     Default=SYN                                    2. Press key enter data and into PV.DP setting page
        PV.DP(PV Decimal Point)                        1.Decide PV,PP decimal point with digit 1 & (0~3)
  4     Default= 0                                     2. Press key enter data and into TV.DP setting page
  5     TV.DP(TV Decimal Point)                        1.Decide TV.DP decimal point with digit 1 & (0~3)
        Default= 0                                     2. Press key enter data and into SCAL setting page
  6     SCAL(Scale)                                    1.Decide display scale with per digit & key(0.001~9.999)
                                                       2. Press key enter data and into OP.MO setting page
        Default = 1.000
  7     OP.MO(Output Mode)                             1.decide output mode with digit 1 & (N,R,C)
        Default= N                                     2. Press key enter data and into ACT setting page
  8     ACT.(Active Time)                              1.Decode active time with digit 1~3 & key(0.1~99.9sec)
        Default = 1.0                                  2. Press key enter data and into CODE setting page
  9     CODE(Code)                                     1.Decide page code with per digit & key (0~9999)
        Default = 0000                                 2. Press key enter data and into LOCK setting page
 10     LOCK(Panel Lock)                               1.Decode panel lock with digit 1 & key(NO,YES)
        Default = NO                                   2.Press key return normal display
 Step    Parameter Mark Description Parameter Mark                             Operation Manual
  1     Setting one-alarm alarm value              1.In normal display,decode one-alarm alarm value with per digit & key
        Default = 0000                              (0~9999)
                                                        ,no key in any key 5 sec. Auto save data
  2     Setting totalizer alarm value                  1.Press AL/SE Tkey
        Default=0000                                   2.Decide totalizer alarm value with per digit   & key (0~9999)
                                                        ,no key in any key 5 sec. Auto save data