Offline Filtration Systems
15...170 NFF2 0020-0270
Filters . Accumulators
Mobile filtration systems with
integral motor-pump units
For temporary or permanent
installation using offline flow
Reduce usage of main flow
filters, extending life of more
expensive elements
Filtration of fresh and top-up
fluids.
Flushing of contaminated
systems or reservoirs
Upgrade filtration on existing
systems
Low pressure drop
High efficient special filter Flow rate 10-170 l/min
media
Special sizes on request
Offline Filtration Systems Guideline for selection
Initial pressure drop : 0,1-0,5 bar at operating viscosity
Selection in accordance to flow and reservoir capacity
15-170 NFF2....
Operating temperature - 100C to + 1000C Reservoir capacity
volume V
Circulation time
time t
Circulation factor
factor f*
< 1000 I 30 min 2
Application 1000 I - 5000 I 60 min 1
Filtration of pressurised liquids and 5000 I - 10000 I 120 min 0,5
lubricants. Separate installation in the > 10000 I 180 min 0,33
offline or cooling circuit for fine filtration and
relief for main filter. Filtration of fresh oil and Achievable oil cleanliness as per ISO 4406
flushing of contaminated systems. Calculation H1XL H3XL H10XL
example
Wear protection of components and
5 12/9/5 13/11/8 17/15/12
systems. 10 10/7/2 12/10/6 15/14/10
Design Reservoir capacity : 3500 I
Mobile filtration system mounted on 2- or 4- Recommended circulation factor : 1
wheel-cart with EPE-series filter. Needed pump flow:
V x f = 3500 x I = 58,3 l/min
Material : as per spare parts list in this Q=
t 60
brochure.
Chosen size : 80 l/min, 80 NFF2 0120
Filter Element
* circulation factor (f) indicates how often the system capacity
Pleated design with optimised pleat density
in liters (l) passes the filter system in one hour.
and various filter media. The filter elements
The higher this factor the faster the flushing or cleaning
is the most important component of the filter process will be.
in view of prolonged life and wear protection
of the system. Filtering Media
Oil cleanliness, the initial pressure drop and The Main Filters are supplied with a variety of Elements including
the dirt holding capacity are the most Disposable Glass Fibre Media in 1, 3, 6, 10 & 20 µ(absolute)
important criteria for selection. Reusable SS Mesh in 10, 25, 40, 60 µ(nominal) & above
For further detailed information please refer Disposable Paper Media in 5,10 & 25 µ(nominal)
our “Filter Elements” brochure. Disposable Polypropylene Media in 10,25 & 40 µ(nominal)
Disposable Water Absorbing Media in 1, 3, 6, 10 & 20 µ(absolute)
Accessories
Maintenance Indicators
For monitoring the filter element’s The Suction Filters are supplied with reusable SS Mesh Element
of 800 µ(nominal) rating.
contamination status, visual and
visual/electrical indicators, with one or two
switching points are available. Maintenance Indicators
Bypass Valve
To protect the filter element during start up Maintenance indicators are used for monitoring the filter
and over pressurisation due to clogging. element’s contamination status. They are available as visual or
visual / electrical indicators.
Vent Valve
For removing the air from the filter during
starting and for safe de-pressurisation.
Particle Counter
Most industry today need to know the oil
cleanliness level. We can provide an
integrated particle counter to give results in
ISO/SAEClasses. Software for connecting
the computer to the particle counter is also 1
2 1+
possible. 1
P Green
-
P
2
3 2
3
3
Red
Dimensions
Ordering code / Spare Parts List
Filter System
15 NFF2 0020...-A00-07A2, 5-00P00 20 NFF2 0020...-A00-07A2, 5-00P00 40 NFF2 0045...-A00-07A2, 5-00P00
consisting of
Volume Flow Rate 15 l/min 20 l/min 40 l/min
Main Filter 40 FLE 0020...-A00-07A2, 5-R0P00 40 FLE 0020...-A00-07A2, 5-R0P00 40 FLE 0045...-A00-07A2, 5-R0P00
Maintenance Indicator Visual (Pop-up / Gauge type), Electric Switch {F2,5 GW 02 00P}
Main Filter Element 1.0020...-A00-0-P 1.0020...-A00-0-P 1.0045...-A00-0-P
Suction Filter 40 LE 0008 G800-A00-000-00P00 40 LE 0008 G800-A00-000-00P00 40 LE 0015 G800-A00-000-00P00
Suction Filter Element 2.0008 G800-A00-O-P 2.0008 G800-A00-O-P 2.0015 G800-A00-O-P
Mounting Mobile with 2 wheels
Hose 2m + lance 1m
Nominal Size Ø 16 / Ø 16 Ø 16 / Ø 16 Ø 25 / Ø 30
Suction/Pressure
Electrical Data 415 V; 50 Hz; 1HP 415 V; 50 Hz; 1HP 415 V; 50 Hz; 1.5HP
Pump Pressure Max 8 bar
Viscosity Range 6-220 mm2/s (up to 1000mm2/s on request)
Filter fineness see Guideline for selection page 2, category “Filtering Media”
Special design on request
Dimensions
Ordering code / Spare Parts List
Filter System
80 NFF2 0120...-A00-07A2, 5-00P00 120 NFF2 0200...-A00-07A2, 5-00P00
consisting of
Volume Flow Rate 80 l/min 120 l/min
Main Filter 40 FLE 0120...-A00-07A2, 5-R0P00 40 FLE 0200...-A00-07A2, 5-R0P00
Maintenance Indicator Visual (Pop-up / Gauge type), Electric Switch {F2,5 GW 02 00P}
Main Filter Element 1.0120...-A00-0-P 1.0200...-A00-0-P
Suction Filter 40 LE 0020 G800-A00-000-00P00 40 FLE 0020 G800-A00-000-00P00
Suction Filter Element 2.0020 G800-A00-O-P 1.0020 G800-A00-O-P
Mounting Mobile with 2 wheels
Hose 2m + lance 1m
Nominal Size Ø 30 / Ø 45 1-1/2” / 1-1/2”
Suction/Pressure
Electrical Data 415 V; 50 Hz; 3HP 415 V; 50 Hz; 5HP
Pump Pressure Max 8 bar
Viscosity Range 6-220 mm2/s (up to 1000mm2/s on request)
Filter fineness see Guideline for selection page 2, category “Filtering Media”
Special design on request
Dimensions
Ordering code / Spare Parts List
Filter System
145 NFF2 0270...-A00-07A2, 5-00P00 170 NFF2 0270...-A00-07A2, 5-00P00
consisting of
Volume Flow Rate 145 l/min 170 l/min
Main Filter 40 FLE 0270...-A00-07A2, 5-R0P00 40 FLE 0270...-A00-07A2, 5-R0P00
Maintenance Indicator Visual (Pop-up / Gauge type), Electric Switch {F2,5 GW 02 00P}
Main Filter Element 1.0270...-A00-0-P 1.0270...-A00-0-P
Suction Filter 40 FLE 0020 G800-A00-000-00P00 40 FLE 0020 G800-A00-000-00P00
Suction Filter Element 1.0020 G800-A00-O-P 1.0020 G800-A00-O-P
Mounting Mobile with 4 wheels
Hose 2m + lance 1m
Nominal Size 2” / 2” 2” / 2”
Suction/Pressure
Electrical Data 415 V; 50 Hz; 7.5HP 415 V; 50 Hz; 7.5HP
Pump Pressure Max 8 bar
Viscosity Range 6-220 mm2/s (up to 1000mm2/s on request)
Filter fineness see Guideline for selection page 2, category “Filtering Media”
Special design on request
Disposal Guidelines - Filters
Disposal
Before the filter is sent for disposal or recycling, it should
always be de-pressurised completely. It is suggested that
the filter is dismantled and the components disposed of as
industrial waste.
Fluid residues are to be drained completely before disposal
/ recycle of the accumulator.
Filter Elements - Oil from the used filter elements is to be
drained before the element is sent for disposal or recycling.
Decontaminate if needed and in accordance with local
regulations.
Environmental Protection
Careless disposal of the product and/or residual fluid
contained therein can cause environmental pollution.
Dispose the product in accordance with provisions
applicable in the country of use.
Fluid residues are to be disposed according to the
respective safety data sheets (MSDS) valid for the specific
hydraulic fluids.
Techni Towers
C-54/A, A.P.I.E., Balanagar
U VE
Hyderabad -500 037, Telangana, India. A
RI
BURE
ISO 9001:2008
TAS
Tel. Nos. : 23778803/23778804/23871445 BUREAU VERITAS
Certification UKAS
MANAGEMENT
Fax Nos. : 040-23871447. 1828
SYSTEMS
008
Internet : www.epe-india.com
E-mail : business@epe-india.com Catalogue Ref. : EPE/Disp/15-16/002
1
Disposal Guidelines - Accumulators
Disposal
Before the accumulator is sent for disposal or recycling, it
should always be discharged completely of the pre-charge
pressure and the gas valve unscrewed. Pre-loading and
checking kits are suited for this task.
For permanently sealed design Diaphragm Accumulators
(Version-P) the diaphragm is preferably damaged on a test
rig or the accumulator is carefully drilled (Ø ≥ 6 mm) on
the gas chamber using a suitable clamp. As the gas flowing
out can draw metal splinters or particles with it, safety
glasses must be worn.
Fluid residues are to be drained completely before disposal
/ recycle of the accumulator. Decontaminate if needed and
in accordance with local regulations.
Environmental Protection
Careless disposal of the product and/or residual fluid
contained therein can cause environmental pollution.
Dispose the product in accordance with provisions
applicable in the country of use.
Fluid residues are to be disposed according to the
respective safety data sheets (MSDS) valid for the specific
hydraulic fluids.
Techni Towers
C-54/A, A.P.I.E., Balanagar
U VE
Hyderabad -500 037, Telangana, India. A
RI
BURE
ISO 9001:2008
TAS
Tel. Nos. : 23778803/23778804/23871445 BUREAU VERITAS
Certification UKAS
MANAGEMENT
Fax Nos. : 040-23871447. 1828
SYSTEMS
008
Internet : www.epe-india.com
E-mail : business@epe-india.com Catalogue Ref. : EPE/Disp/15-16/001