HDG
SECTION
                                                                   THICKNESS
                                                         SR. NO    (mm)
A   SURFACE AREA/TONNE            25.5                           1 1mm
    SECTION AREA IN mm              10                           2 2mm
                                                                 3 3mm
B   MASS/SQ.METER(gm/sq.m)         8.5                           4 4mm
    SECTION THICKNESS IN mm         10                           5 5mm
                                                                 6 6mm
C   COATING MASS(gm/sq.m)        352.5                           7 8mm
    COATING THICKNESS(µm)           50                           8 10mm
                                                                 9 12mm
D   COATING THICKNESS(µm)          1.4                          10 15mm
    COATING MASS(gm/sq.m)           10                          11 20mm
                                                                12 25mm
                   HOT ROLLED SECTIONS & HEAVIER STEEL SECTION WILL GENERATES CONSIDERABLY THICK
                   STANDARD FOR HOT DIP GALVANISING IS CONSIDERED ISO 1461 AS PER SUZLON SEG-ED-1
           SURFACE                  MINIMUM                MINIMUM
           AREA/TON                 HDG        AVG.        HDG
           NE (SQ.                  COATING    COATING COATING
           METER/      MASS/SQ.M THICKNESS WT/ SQ.M THICKNESS
           TONNE)      (Kg/SQ.M) (µm)          (gm/sq.m) (µm)
                   255         7.85         45         320         45
                   127         15.7         55         390         55
                    85        23.55         55         390         55
                    64         31.4         70         500         70
                    51        39.25         70         500         70
                    42         47.1         70         500         70
                    32         62.8         85         600         85
                    25         78.5         85         600         85
                    21         94.2         85         600         85
                    17       117.75         85         600         85
                    13          157         85         600         85
                    10       196.25         85         600         85
GENERATES CONSIDERABLY THICKER COATING
 O 1461 AS PER SUZLON SEG-ED-113-09-00233
INTERESTING FACTS ABOUT GALVANISATION
        MICROGRAPHIC PHOTO OF GALVANISING COATING
                 SCHEMATIC PROCESS
        GALVANISED COATING PERFORMANCE IN DIFFERENT TYPE SOIL
STANDARDS
DURABILITY OF HDG
        GALVANIC SERIES OF METAL
GOOD PERFORMANCE OBTAINED BETWEEN LIQUID OF PH 4 TO 12.5
GOOD PERFORMANCE OBTAINED IN FRESH WATER(ALL WATER EXCEPT SEA WATER=FRESH WATER)
TEMPERATURE RESISTANCE OF CONTUNUOUS EXPOSURE= 200 DEG. C
                METAL COMPOSITION FOR HDG
z
=FRESH WATER)
                                                                          Author:
                                                                          LIFE SPAN 25 YR
                                                                          CONSIDERED
                                      AS PER ISO 12944
SR. NO            ZINC LOS AFTER 1 YR. EXPOSURE
                                MASS OF     HDG COATING        HDG COATING
          CORROSION             LOSS        THICKNESS          THICKNESS
          CATEGORY              (gm/m2)     REDUCTION (µm)     REQUIREMENT (µm)
         1 C1                   <0.7        ≤0.1                             2.5
         2 C2                   0.7-5       >0.1-0.7                        17.5
         3 C3                   >5-15       >0.7-2.1                        52.5
         4 C4                   >15-30      >2.1-4.2                       78.75
         5 C5 I                 >30-60      >4.2-8.4                       157.5
         6 C5 M                 >30-60      >4.2-8.4                       157.5
NOTES :                   THIS DATA IS BASED ON LOSS OF WT OF ZINC OF HDG COATING AS PER ISO 12944 W
    IN SUZLON STANDARD SEG- ED-133-09-00233 FOR HDG REFERAL STANDARD IS EN ISO 1461 FOR MINIMUM H
         FINAL COATING THICKNESS IS TO BE TAKEN FROM ISO 1461 FOR MINIMUM HDG COATING THICKNESS T
   Author:
   LIFE SPAN 25 YR
   CONSIDERED
          SAFETY MARGINE
          MINIMUM
          THICKNESS OF HDG
          (µm)
                         4.5
                          21
                     55.125
                    82.6875
                    165.375
                    165.375
G COATING AS PER ISO 12944 WHICH IS INDEPENDENT OF STEEL THICKNESS.
IS EN ISO 1461 FOR MINIMUM HDG THICKNESS FOR FABRICATING IRON & STEEL ARTICLES
UM HDG COATING THICKNESS TO AVOID EXESS HDG COST FOR EXCESS ZINC
HOT DIP GALVANISING COATING THICKNESS
ATING THICKNESS ACCORDING TO EN ISO 1461
                    PRECAUTIONS DURING DEVELOPING OF HDG PART
SR. NO     KEY POINTS
            ARE THE VENT & DRAIN HOLES ARE SUFFICIENT IN SIZE & NUMBERS AS PER STANDARD-
          1 ISO 14713 PART 1 ?
          2 ARE THE VENT & DRAIN HOLES ARE LOCATED PROPERLY?
            ARE THE CORNER OF GUSSETS, STIFFENERS, BRACING CROPPED TO ALLOW FREE FLOW
          3 OF ZINC?
          4 ARE WELDS AT OVERLAPPING SURFACES SEAL WELDED?
          5 DOES FABRICATOR KNOWS TO REMOVE ALL WELD FLUX?
            HAVE ACCOUNTED MARKING & TRACKING OF PARTS THROUGH GALVANISING PROCESS
          6 AND ON SITE?
          7 HAVE PLANNED FOR TAPPING OF THREADED HOLES OR NUTS AFTER GALVANISING
            WILL THE STEEL SURFACE EXHIBITS EXTREME DEVELOPMENT OF MILL SCALES WHICH
            CAN NOT MOVED IN CHEMICAL CLEANING OR REQUIRED MECHANICAL CLEANING LIKE
          8 BLASTING/WIREBRUSHING
          9 ARE THERE SHARP BENDS IN FABRICATION?
         10 ARE THERE SECTIONS WHERE WIRE ROPE/CHAIN OF LIFTING CRANE CAN BE CONNECTED
            ARE THERE ANY DIFFERENT STEEL PARTS OF VARYING THICKNESS GOING TO WELD
         11 BEFORE GALVANISING
         12 HAVE WE USED PROPER WELD METAL LIKE ROD OF SILICONE LEVEL LESS THAN 0.25%
         13 IS THE GALVANISED PART WILL FURTHER COATED?
         14 DOES THE STEEL ASSEMBLY CONTAIN MOVING PARTS?
         15 ARE THERE THREADED HOLES/ CLEARANCE HOLES IN PARTS?
         16 WILL THE FABRICATION FEET IN THE HDG KETTLE?
         17 HAVE THE STANDARD REFER LIKE ASTM A 153, ASTM A385, ASTM A 123?
         18 WHAT SAMPLING METHOD WILL BE USED?
         19 HAVE WE STIPULATED CERTIFICATE OF CONFORMANCE BY GALVANISER?
         20 HAVE THE END USE IS COMMUNICATED TO FABRICATOR & GALVANISER?
         21 ANY SPECIAL PACKING REQUIRED FOR LONG STORAGE?
         22 WHAT IS EXPECTED COATING FINISH & CORROSION PROTECTION?
         23 WHAT TOUCH UP METHOD REQUIRED FOR DAMAGE OR BARE SPOT (ASTM A 780)
SR. NO.      STANDARD NAME       DESCRIPTION
           1 ASTM A 385 03       STANDARD PRACTICE FOR PROVIDING HIGH QUALITY ZINC COATINGS (HOT DIP)
           2 ASTM A 153/153M-03 STANDARD SPECIFICATION FOR ZINC COATING ON IRON & STEEL HARDWARE (HOT DIP)
           3 ASTM A 780-01      PRACTICE FOR REPAIR OF DAMAGED & UNCOATED AREAS OF HDG COATINGS
                                 STANDARD SPECIFICATION FOR ZINC COATED (GALVANISED) STEEL BARS FOR CONCRETE
           4 ASTM A 767/767M     RENFORCEMENT
           5 ASTM A 384/384M     STANDARD PRACTICE FOR SAFEGUARDING AGAINST WARPAGE & DISTORTION DURING HD
                                 STANDARD PRACTICE AGAINST SAFEGUARDING THE AGAINST EMBRITTLEMENT OF STRUCT
           6 ASTM A 143/143M     PRODUCTS & PROCEDUCRE FOR DETECTING EMBRITTLEMENT
                                 STANDARD SPECIFICATION FOR ZINC (HOT DIP GALVANISED COATINGS ON IRON & STEEL P
           7 ASTM A123/123M      COVERS INDIVIDUAL PIECES OR ASSEMBLIES OF VARIOUS CLASSES OF MATERIALS
           8 ISO 1461            HOT DIP GALVANISED COATINGS ON FABRICATED IRON & STEEL ARTICLES
                                 GUIDELINE & RECOMMENDATION FOR THE PROTECTION AGAINST CORROSION OF IRON &
           9 ISO 14713:2009      STRUCTURE
          10 ISO 14713:2009 PART1 GENERAL PRINCIPLE OF DESIGN & CORROSION PROTECTION
          11 ISO 14713:2009 PART2 HOT DIP GALVANIZING
          12 ISO 14713:2009 PART3 SHERARDIZING
TINGS (HOT DIP)
L HARDWARE (HOT DIP)
DG COATINGS
EEL BARS FOR CONCRETE
& DISTORTION DURING HDG
MBRITTLEMENT OF STRUCTURAL STEEL
ATINGS ON IRON & STEEL PRODUCTS
 ES OF MATERIALS
L ARTICLES
NST CORROSION OF IRON & STEEL IN