Report Roof Structure
Report Roof Structure
5000
ACA-01
TOP ROOF STRUCTURE
DETAILS
ACA-02
STRUCTURAL DESIGN REPORT
TOP ROOF STRUCTURE
TABLE OF CONTENTS:
1. Introduction.
2. Codes and standards
2.1 International Codes and Standards
2.2 Projects Standards
3. Reference Drawings & Documents
4. Material Specifications
5. Loads and Load combinations
5.1 Primary Loads
5.2 Load combination
6. Computer Programs Used for Design
7. Geometrical views
8. Load calculations
8.1 Self-Weight of Structure
8.2 Dead Loads of Structure
8.3 live load
8.4 Wind Load
This document describes the general requirements and design parameters that would be used for the
design of Steel Structure for Sheds in U.A.E. All loadings and Assumptions are made as per design basis
report submitted .
Which do not affect analysis and design results can be seen between overall dimensions explained above and
steel drawings. Steel drawings are in a full concordance with architectural drawings.)
The structure has been designed to resist vertical and horizontal load effects such as dead loads, roof
live loads and wind loads.
The structural investigation of Shelters shall be performed making use of the STAAD Pro program.
The structure will be modeled as a 3D component.
The following codes will be referred to for the design / specification related to this design
Code Description
ASCE 7-05 Minimum design loads for buildings and other structures
AISI-NAS North American specification for the design of cold-formed steel structural members
4. Material Specifications:
Cold formed steel ASTM A653 Grade SS50, Class I Fy = 345 N/mm 2
Note:
Steel Properties:
Dead Load
Live Load
Wind Load
Temp
1.2 DL +1.6 LL
1.2DL +1.6LL
1.2DL +1.6WL
0.9DL+1.6WL
1.0DL +1.0LL
Used programmers:
The Mainframe Steel structure will be analyzed using Municipality Approved Design Software STAAD.Pro v8i for
Hot Rolled Steel Elements.
In addition to the professional software, in house developed excel spread sheets will be also used to supplement
details where required.
All computer-generated results such as member forces, support reactions, displacements will be provided.
Graphical output of analysis results such as bending moment diagrams, shear force diagram, displacement
diagrams, mode shapes etc. will be provided to substantiate the numerical output.
Upon design finalization, full model of the structure will be prepared using AutoCAD software for fabrication
assistance.
Upon Request from Client software generated ‘Erection Drawings’ and Anchor Bolt Layout drawings would be
provided.
7. Geometrical views
8. Load calculations
Windward face
Cofficient( Pressure
Load case
CNW) (qz*G*CN)
wind dwn 1.2 1.2852
wind up -0.85 -0.91
www.hilti.co.uk
Company: Page: 1
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HST3 M12 hef2
Return period (service life in years): 50
Item number: 2105719 HST3 M12x115 40/20
Filling set or any suitable annular gap filling solution
Effective embedment depth: hef = 70.0 mm, hnom = 80.0 mm
Material:
Evaluation Service Report: ETA 98/0001
Issued I Valid: 7/13/2020 | -
Proof: SOFA design method + fib (07/2011) - after ETAG testing
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm
Anchor plate :
R lx x ly x t = 180.0 mm x 320.0 mm x 12.0 mm; (Recommended plate thickness: not calculated)
Profile: Advance UKB, 305 x 165 x 46; (L x W x T x FT) = 306.6 mm x 165.7 mm x 6.7 mm x 11.8 mm
Base material: cracked concrete, C35/45, fc,cyl = 35.00 N/mm ; h = 800.0 mm
2
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 2
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
5 1
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.167 2.438 -1.751 1.696
2 0.167 2.084 2.084 -0.030 3 4 x
3 0.167 0.169 0.167 -0.030 Tension
4 0.167 1.704 0.167 1.696
5 0.167 1.751 -1.751 -0.030
6 0.167 2.687 2.084 1.696 2 6
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 3
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
Group anchor ID
1-6
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 4
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
Group anchor ID
6
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 5
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.005 0.095 2.000 1 OK
concrete 0.020 0.104 1.500 4 OK
a a
bN + bV <= 1
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2018, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Filling set) or by other suitable means
• The compliance with current standards (e.g. EN 1993, AS 4100:1998, etc.) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 6
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
8 Installation data
2 2
Anchor plate, steel: S 275; E = 210,000.00 N/mm ; fyk = 275.00 N/mm Anchor type and diameter: HST3 M12 hef2
Profile: Advance UKB, 305 x 165 x 46; (L x W x T x FT) = 306.6 mm x 165.7 Item number: 2105719 HST3 M12x115 40/20
mm x 6.7 mm x 11.8 mm
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 60 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 12.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 88.0 mm
Drilling method: SafeSet - automatic cleaning Minimum thickness of the base material: 140.0 mm
Cleaning: Automatically performed while drilling
Hilti HST3 stud anchor with 80 mm embedment, M12 hef2, Steel galvanized, installation per ETA 98/0001, with annular gaps filled with Hilti
Filling set or any suitable gap solutions
y
90.0 90.0
60.0
5 1
160.0
100.0
3 4
x
100.0
160.0
2 6
60.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 7
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.71
www.hilti.co.uk
Company: Page: 8
Address: Specifier: Mohammed Siddiq
Phone I Fax: | E-Mail:
Design: END PLATE (1) Date: 8/23/2021
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
base plate calculation
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HIT-RE 500 V4 + HAS-U 5.8 M20
Return period (service life in years): 50
Item number: 2223874 HAS-U 5.8 M20x240 (element) / 2287553
HIT-RE 500 V4 (adhesive)
Effective embedment depth: hef,act = 150.0 mm (hef,limit = - mm)
Material: 5.8
Evaluation Service Report: ETA 20/0541
Issued I Valid: 11/21/2020 | -
Proof: Design Method ETAG BOND (EOTA TR 029)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 20.0 mm
Anchor plate :
R lx x ly x t = 400.0 mm x 400.0 mm x 20.0 mm; (Recommended plate thickness: not calculated)
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
V
VSd £ VRd,s = Rk,s EOTA TR 029, Table 5.2.3.1
gM,s
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
V
VSd £ VRd,cp = Rk,cp EOTA TR 029, Table 5.2.3.1
gM,c,p
VRk,cp = k · min (NRk,p; NRk,c) EOTA TR 029, Eq. (5.7), (5.7a)
0 A
NRk,p = NRk,p · p,N
0
· y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EOTA TR 029, Eq. (5.2)
Ap,N
0
NRk,p = p · d · hef · t Rk EOTA TR 029, Eq. (5.2a)
0
Ap,N = scr, Np · scr,Np EOTA TR 029, Eq. (5.2b)
0.5
t Rk,ucr
scr,Np = 20 · d · (7.5 )
£ 3 · hef EOTA TR 029, Eq. (5.2c)
scr,Np
ccr,Np = EOTA TR 029, Eq. (5.2d)
2
c
y s,Np = 0.7 + 0.3 · 1.00 EOTA TR 029, Eq. (5.2e)
ccr,Np £
0,5
y g,Np
0
= y g,Np - (s s )
cr,Np
· (y g,Np - 1) ³ 1.00
0
EOTA TR 029, Eq. (5.2f)
1,5
0
y g,Np = √n - (√n - 1) · (k · √dh · t· f ef
Rk
ck,cube
) ³ 1.00 EOTA TR 029, Eq. (5.2g)
1
y ec1,Np = 1.00 EOTA TR 029, Eq. (5.2h)
2 · ec1,V £
1+
scr,Np
1
y ec2,Np = 1.00 EOTA TR 029, Eq. (5.2h)
2 · ec2,V £
1+
scr,Np
h
y re,Np = 0.5 + ef £ 1.00 EOTA TR 029, Eq. (5.2i)
200
2 0 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,25 [N/mm ] ccr,Np [mm] scr,Np [mm] cmin [mm]
562,500 202,500 13.00 225.0 450.0 ∞
0
yc t Rk,cr [N/mm ]
2
k k-factor y g,Np y g,Np
1.072 8.57 2.300 2.000 1.201 1.037
Group anchor ID
1-4
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2018, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
7 Installation data
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm
2 2 Anchor type and diameter: HIT-RE 500 V4 + HAS-U 5.8
M20
Profile: Square hollow, 250 x 250 x 8,0; (L x W x T) = 250.0 mm x 250.0 mm x Item number: 2223874 HAS-U 5.8 M20x240 (element) /
8.0 mm 2287553 HIT-RE 500 V4 (adhesive)
Hole diameter in the fixture: df = 22.0 mm Maximum installation torque: 150 Nm
Plate thickness (input): 20.0 mm Hole diameter in the base material: 22.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 150.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 194.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required
Hilti HAS-U threaded rod with HIT-RE 500 V4 injection mortar with 150 mm embedment h_ef, M20, Steel galvanized, Hammer drilled
installation per ETA 20/0541
y
200.0 200.0
50.0
3 4
200.0
300.0
x
200.0
1 2
50.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.71
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Aug 15, 2021 Date: 8/23/2021
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
top roof secondary beam connection design
Page 1 of 2
23/08/2021
12:31:20
Administrator
Job: colum beam connection -- Connection: ColumnBeamconnecti
50
50
50
60
60
60
By Date06-Jan-21 Chd
Job Information
Engineer Checked Approved
Name:
Date: 06-Jan-21
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 13
Job No Sheet No Rev
2
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Nodes
Node X Y Z
(m) (m) (m)
1 0.000 0.000 0.000
2 0.000 18.500 0.000
3 7.465 0.000 0.000
4 7.465 18.500 0.000
7 0.000 8.500 0.000
8 7.465 8.500 0.000
11 0.000 4.100 -4.475
13 7.465 8.500 -4.475
14 0.000 8.500 -4.475
15 0.000 13.050 -4.475
16 7.465 13.050 -4.475
17 7.465 4.100 -4.475
18 0.000 18.500 -4.475
19 7.465 18.500 -4.475
20 8.445 18.500 0.000
21 -0.980 18.500 0.000
22 -0.980 18.500 -4.870
23 8.445 18.500 -4.870
24 1.495 18.500 0.000
25 2.990 18.500 0.000
26 1.495 18.500 -4.870
27 2.990 18.500 -4.870
28 4.485 18.500 -4.870
29 4.485 18.500 0.000
30 5.980 18.500 -4.870
31 5.980 18.500 0.000
33 -0.980 18.500 0.925
34 8.445 18.500 0.925
35 -0.000 18.500 0.925
36 1.495 18.500 0.925
37 2.990 18.500 0.925
38 4.485 18.500 0.925
39 5.980 18.500 0.925
40 7.465 18.500 0.925
41 0.000 18.500 -4.870
42 7.465 18.500 -4.870
43 -0.980 18.500 -5.325
44 8.445 18.500 -5.325
47 0.000 4.100 0.000
48 7.465 4.100 0.000
49 7.465 13.050 0.000
50 0.000 13.050 0.000
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 2 of 13
Job No Sheet No Rev
3
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Beams
Beam Node A Node B Length Property
(m) (degrees)
5 47 48 7.465 4 0
8 7 8 7.465 4 0
11 50 49 7.465 4 0
13 11 47 4.475 4 0
14 14 7 4.475 4 0
15 13 8 4.475 4 0
16 15 50 4.475 4 0
17 16 49 4.475 4 0
18 17 48 4.475 4 0
19 18 2 4.475 2 0
20 19 4 4.475 2 0
21 2 24 1.495 3 0
22 4 20 0.980 3 0
23 21 2 0.980 3 0
24 22 21 4.870 2 0
25 23 20 4.870 2 0
27 24 25 1.495 3 0
28 25 29 1.495 3 0
29 26 27 1.495 3 0
30 26 24 4.870 2 0
31 27 28 1.495 3 0
32 27 25 4.870 2 0
33 28 30 1.495 3 0
34 29 31 1.495 3 0
35 28 29 4.870 2 0
37 31 4 1.485 3 0
38 30 31 4.870 2 0
39 33 35 0.980 2 0
40 21 33 0.925 2 0
41 35 36 1.495 2 0
42 2 35 0.925 2 0
43 36 37 1.495 2 0
44 24 36 0.925 2 0
45 37 38 1.495 2 0
46 25 37 0.925 2 0
47 38 39 1.495 2 0
48 29 38 0.925 2 0
49 39 40 1.485 2 0
50 31 39 0.925 2 0
51 40 34 0.980 2 0
52 4 40 0.925 2 0
53 20 34 0.925 2 0
54 41 26 1.495 3 0
55 42 23 0.980 3 0
56 30 42 1.485 3 0
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 3 of 13
Job No Sheet No Rev
4
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
57 22 41 0.980 3 0
58 22 43 0.455 2 0
59 23 44 0.455 2 0
63 47 7 4.400 1 0
64 48 8 4.400 1 0
65 49 4 5.450 1 0
66 50 2 5.450 1 0
67 7 50 4.550 1 0
68 8 49 4.550 1 0
69 47 1 4.100 1 0
70 3 48 4.100 1 0
Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 TUB2502508.0 76.800 7.46E+3 7.46E+3 11.5E+3 STEEL
2 UB254X146X31 39.700 448.000 4.41E+3 8.552 STEEL
3 UB356X171X51 64.900 968.000 14.1E+3 23.811 STEEL
4 UB305X165X46 58.700 896.000 9.9E+3 22.196 STEEL
Materials
Mat Name E Density
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 4 of 13
Job No Sheet No Rev
5
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Supports
Node X Y Z rX rY rZ
(kN/mm) (kN/mm) (kN/mm) (kN-m/deg) (kN-m/deg) (kN-m/deg)
1 Fixed Fixed Fixed - - -
3 Fixed Fixed Fixed - - -
11 Fixed Fixed Fixed - - -
13 Fixed Fixed Fixed - - -
14 Fixed Fixed Fixed - - -
15 Fixed Fixed Fixed - - -
16 Fixed Fixed Fixed - - -
17 Fixed Fixed Fixed - - -
18 Fixed Fixed Fixed - - -
19 Fixed Fixed Fixed - - -
41 Fixed Fixed Fixed - - -
42 Fixed Fixed Fixed - - -
Releases
There is no data of this type.
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 5 of 13
Job No Sheet No Rev
6
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Load Generators
There is no data of this type.
Y -1.000 ALL
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 6 of 13
Job No Sheet No Rev
7
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 7 of 13
Job No Sheet No Rev
8
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 8 of 13
Job No Sheet No Rev
9
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 9 of 13
Job No Sheet No Rev
10
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Utilization Ratio
Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
5 UB305X165X46UB305X165X460.112 1.000 0.112 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
8 UB305X165X46UB305X165X460.057 1.000 0.057 Eq. H1-1b 12 58.700 9.9E+3 896.000 22.196
11 UB305X165X46UB305X165X460.106 1.000 0.106 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
13 UB305X165X46UB305X165X460.016 1.000 0.016 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
14 UB305X165X46UB305X165X460.026 1.000 0.026 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
15 UB305X165X46UB305X165X460.026 1.000 0.026 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
16 UB305X165X46UB305X165X460.029 1.000 0.029 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
17 UB305X165X46UB305X165X460.029 1.000 0.029 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
18 UB305X165X46UB305X165X460.017 1.000 0.017 Eq. H1-1b 11 58.700 9.9E+3 896.000 22.196
19 UB254X146X31UB254X146X310.050 1.000 0.050 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
20 UB254X146X31UB254X146X310.051 1.000 0.051 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
21 UB356X171X51UB356X171X510.318 1.000 0.318 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
22 UB356X171X51UB356X171X510.117 1.000 0.117 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
23 UB356X171X51UB356X171X510.118 1.000 0.118 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
24 UB254X146X31UB254X146X310.259 1.000 0.259 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
25 UB254X146X31UB254X146X310.260 1.000 0.260 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
27 UB356X171X51UB356X171X510.352 1.000 0.352 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
28 UB356X171X51UB356X171X510.353 1.000 0.353 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
29 UB356X171X51UB356X171X510.432 1.000 0.432 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
30 UB254X146X31UB254X146X310.421 1.000 0.421 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
31 UB356X171X51UB356X171X510.433 1.000 0.433 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
32 UB254X146X31UB254X146X310.414 1.000 0.414 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
33 UB356X171X51UB356X171X510.433 1.000 0.433 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
34 UB356X171X51UB356X171X510.349 1.000 0.349 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
35 UB254X146X31UB254X146X310.413 1.000 0.413 Eq. H1-1b 11 39.700 4.41E+3 448.000 8.552
37 UB356X171X51UB356X171X510.335 1.000 0.335 Eq. H1-1b 11 64.900 14.1E+3 968.000 23.811
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 10 of 13
Job No Sheet No Rev
11
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 11 of 13
Job No Sheet No Rev
12
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 12 of 13
Job No Sheet No Rev
13
Part
Software licensed to HP
Job Title Ref
By Date06-Jan-21 Chd
Failed Members
There is no data of this type.
Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 1 15:0.9 DL + 1.6 WL DN
4.892 105.358 -0.016 0.000 0.000 0.000
Min FX 3 16:0.9 DL + 1.6 WL UP
-4.945 48.356 -0.041 0.000 0.000 0.000
Max FY 1 11:1.2 DL + 1.6 LL+ 0.5WL
1.620 118.387 -0.032 0.000 0.000 0.000
Min FY 1 8:TEMP +25 1.964 -19.592 1.830 0.000 0.000 0.000
Max FZ 19 9:TEMP -25 -0.016 -1.862 5.393 0.000 0.000 0.000
Min FZ 19 18:1.2 DL +1.6 LL+1.20.023
TL 3.379 -6.223 0.000 0.000 0.000
Max MX 1 1:SELF WEIGHT 0.159 27.510 -0.059 0.000 0.000 0.000
Min MX 1 1:SELF WEIGHT 0.159 27.510 -0.059 0.000 0.000 0.000
Max MY 1 1:SELF WEIGHT 0.159 27.510 -0.059 0.000 0.000 0.000
Min MY 1 1:SELF WEIGHT 0.159 27.510 -0.059 0.000 0.000 0.000
Max MZ 1 1:SELF WEIGHT 0.159 27.510 -0.059 0.000 0.000 0.000
Min MZ 1 1:SELF WEIGHT 0.159 27.510 -0.059 0.000 0.000 0.000
Print Time/Date: 23/08/2021 13:36 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 13 of 13