STRUCTURAL ANALYSIS
AND
DESIGN COMPUTATION
PROJECT: PROPOSED ONE-STOREY RESIDENTIAL ALTERATION
LOCATION: GOLD ST., RICHLAND SUBDIVISION, BRGY. SAUYO, QUEZON CITY
OWNER: MRS. MARITES ANASTACIO
STRUCTURAL MODEL
DESIGN METHODOLOGY:
ULTIMATE STRENGTH DESIGN
DESIGN LOADS:
Dead Loads
1. Selfweight
Concrete Unit weight = 24 kN/m3
2. Member Load
150 mm CHB = 2.63 + 0.24 + 0.24 = 3.11 kN/m per meter height
100 mm CHB = 2.5 + 0.24 + 0.24 = 2.98 kN/m per meter height
3. Floor Load
Materials Floor Load Roof Load
(kpa) (kpa)
100mm Slab 2.4
Floor Finish 1.10 -
Ceiling 0.348 0.348
MEP 0.10 0.10
Interior 1.00
Partition
Roof framing - 0.41
Corrugated - 0.10
roofing sheet
4. Live Load
Use or Uniform
Occupancy Load
Category Description kPa
Residentia Basic Floor Area 1.9
l
Restroom 1.9
DESIGN CRITERIA
Seismic Design Parameters
Seismic Zone Zone 4; Z=0.40
Seismic Source Type Type B
Importance Factor 1.0
Soil Type SD
Seismic Coefficient, Cv 0.64
Near-source factor, Nv 1.0
Seismic Coefficient, Ca 0.44
1.0
Near-source factor, Na
R Ω Cd
R.C Special Moment Resisting Frame 8.5 3.0 5.5
ALLOWABLE SOIL BEARING PRESSURE = 250 kPa (ASSUMED)
NOTE:
IN CASE SOIL BEARING PRESSURE IS DIFFERENT FROM THE ASSUMED VALUE,
FOUNDATION SHALL BE COMPUTED FOR THAT PARTICULAR VALUE
Wind Design Parameters
Basic Wind Speed, V 270 kph
Exposure Type Type B
Wind Directionality Factor, KD 0.85
Topographic Factor, KZT 1.0
Gust Effect Factor, G 0.64Nv
Enclosure Classification Partially Enclosed
Internal Pressure Coefficient ± 0.55
STAAD INPUT
STAAD OUTPUT
MANUAL COMPUTATION