A - ELSB - Cat - 2020 - II
A - ELSB - Cat - 2020 - II
Catalogue – 2020
Electrical installation
solutions for buildings
• DIN-rail products
• Light switches and wiring accessories
• Home and building automation
• Enclosures
MINIATURE
CIRCUIT-BREAKERS
1
RESIDUAL CURRENT
—
DEVICES
2
Electrical installation solutions
ARC FAULT DETECTION
DEVICES
3
for buildings ACCESSORIES FOR
MCBS AND RCDS
4
PROTECTION
AND SAFETY
5
COMMAND AND
SIGNALING
6
CONTROL AND
AUTOMATION
7
ENERGY EFFICIENCY
8
PLUG -IN SYSTEMS
9
INDUSTRIAL PLUGS
10
AND SOCKETS
11
SOCKET OUTLETS
INSTALL ATION
12
MATERIAL
DIGITAL SERVICES
13
ABB I-BUS® KNX
14
ABB -FREE@HOME®
15
DOOR ENTRY SYSTEM
16
INTRUSION AL ARM
17
SYSTEMS
SUBDISTRIBUTION
18
BOARDS
CONSUMER UNITS
19
AUTOMATION BOARDS
20
JUNCTION BOXES
21
QUICK PRODUCT
22
REFERENCES
2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Two volumes, one objective:
to always find the best solution
From a single catalogue with two complementary
volumes: streamline to simplify, analyse to choose.
The catalog Electrical installation solutions for buildings comes in two separate but integrated
volumes: one dedicated to the description and easy selection of products code and one for
professionals searching for in-depth details and specifications, installation examples and special
technical solutions.
Two volumes that reference each other, which are manageable and easily consultable, designed for
those who wish to find the clearest solution in the least possible time.
1
— The volume
MCBs
S 200 series B characteristic
Electrical installation
solutions for buildings
S 200 B characteristic
Function: protection and control of the circuits against overloads and short-circuits;
Number
of poles
Rated
current
Bbn
4016779
Order details Price Weight
1 piece 1 piece
Pack
unit
can be downloaded here
protection for people and large length of cables in TN and IT systems.
In A EAN Type code Order code kg pc.
2CDC021059S0012
2CDC021176S0010
4 6 528955 S204-B6 2CDS254001R0065 0.500 1
Standard: IEC/EN 60898-1, IEC/EN 60947-2
10 528962 S204-B10 2CDS254001R0105 0.500 1
Icn=6 kA
13 528979 S204-B13 2CDS254001R0135 0.500 1
S 201 S 204 16 528986 S204-B16 2CDS254001R0165 0.500 1
Number Rated Bbn Order details Price Weight Pack
of poles current 4016779 1 piece 1 piece unit 20 528993 S204-B20 2CDS254001R0205 0.500 1
25 529006 S204-B25 2CDS254001R0255 0.500 1
In A EAN Type code Order code kg pc.
32 529013 S204-B32 2CDS254001R0325 0.500 1
1 6 464901 S201-B6 2CDS251001R0065 0.125 10
40 529020 S204-B40 2CDS254001R0405 0.500 1
10 463805 S201-B10 2CDS251001R0105 0.125 10
50 550987 S204-B50 2CDS254001R0505 0.500 1
13 465007 S201-B13 2CDS251001R0135 0.125 10
63 550994 S204-B63 2CDS254001R0635 0.500 1
2CDC021018S0013
2CDC021174S0010
2CDC021013S0013
10 466608 S202-B10 2CDS252001R0105 0.250 5
20 *1 531627 S201-B20NA 2CDS251103R0205 0.250 5
S 203 13 466707 S202-B13 2CDS252001R0135 0.250 5
25 531634 S201-B25NA 2CDS251103R0255 0.250 5
16 466905 S202-B16 2CDS252001R0165 0.250 5
32 *2 531641 S201-B32NA 2CDS251103R0325 0.250 5
20 467001 S202-B20 2CDS252001R0205 0.250 5 S 203 NA 40 *3 531658 S201-B40NA 2CDS251103R0405 0.250 5
25 467100 S202-B25 2CDS252001R0255 0.250 5
50 536158 S201-B50NA 2CDS251103R0505 0.250 5
32 467209 S202-B32 2CDS252001R0325 0.250 5
63 536141 S201-B63NA 2CDS251103R0635 0.250 5
40 467407 S202-B40 2CDS252001R0405 0.250 5
50 550949 S202-B50 2CDS252001R0505 0.250 5
Number Rated Bbn Order details Price Weight Pack
TIP:
63 550956 S202-B63 2CDS252001R0635 0.250 5 of poles current 4016779 1 piece 1 piece unit
address: http://new.abb.
*2 suitable for flow-type heaters 18 kW
63 550970 S203-B63 2CDS253001R0635 0.375 1
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
The volume
Electrical installation
solutions for buildings -
Technical details
can be downloaded here
4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Electrical installation solutions for buildings
Quality of life, living comfort and safety
18
15
11
16
17
14
12
13
5 6
3
1
2
8
10
—
Electrical installation solutions for buildings
Solutions for commercial and industrial buildings
27
1
13
11
4
3
14
6
10
2
9
8
32
28
21
18
20 22
23
24
25
19
26
17
15
12
16
30
29
31
1
—
Electrical installation solutions for buildings
Miniature circuit-breakers
Index
Quick selection of MCBs 1/2
MCBs S 200
S 200 technical features 1/20
S 200 series, 6 kA 1/26
S 200 M series, 10 kA 1/40
S 200 MR series, 10kA 1/54
S 200 M UC series, 10 kA 1/56
S 200 P series, 15/25 kA 1/65
S 200 S screwless series, 6 kA 1/80
SU 200 MR series, 10kA 1/93
S 200 UDC series, 125 V DC 1/95
MCBs SN 201
SN 201 L series, 4.5 kA 1/102
SN 201 series, 6 kA 1/103
SN 201 M series, 10 kA 1/105
MCBs S 200C
S200C series from 3 kA to 10 kA 1/106
SMCBs S 750 DR
S 750 DR series 1/128
MCBs S 800
S800S series, 50 kA 1/142
S800N series, 36 kA 1/167
S800C series, 25 kA 1/173
S800B series, 16 kA 1/177
S800HV series, 4 kA 1/181
S800UP series, 25 kA 1/183
S800U series, 50 kA 1/184
S804U-UCZ series, 10 kA 1/192
S800U series PVS 1/193
S800PV-SP series, 5 kA, DC 1/194
S800PV-SD and S800PV-M-H series 1/197
1/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
System pro M compact®
Quick selection of MCBs for household
and industrial applications
Easy! Find the right range and the corresponding catalogue page at a glance using this selection chart.
3 kA
4.5 kA
6 kA
HOUSEHOLD
Overload + Short-circuit IEC/EN 60898-1
10 kA
15 kA
START
20 kA
25 kA
INDUSTRIAL
Overload + Short-circuit IEC/EN 60947-2
1/3
1
—
System pro M compact®
Quick selection of MCBs for household and industrial applications
Up to 32 A 2 S200CM 1/114
—
System pro M compact®
Quick selection of MCBs for household
and industrial applications
Application Breaking capacity Icn
6 kA
HOUSEHOLD
10 kA
Overload + Short-circuit IEC/EN 60898-1
15 kA
25 kA
START
36 kA
50 kA
100 kA
10 kA
INDUSTRIAL
DC-applications IEC/EN 60947-2
50 kA
1/5
1
—
System pro M compact®
Quick selection of MCBs for household and industrial applications
—
System pro M compact®
Quick selection of MCBs for UL
applications (UL 489/CSA 22.2 No. 5)
10 kA
10 kA
14 kA
10 kA - DC applications
DC applications UL 489B 3 kA
1/7
1
—
System pro M compact®
Quick selection of MCBs for UL applications (UL 489/CSA 22.2 No. 5)
5A 4P S804U-PVS5 1/193
1/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
Miniature circuit-breakers
Selection table
S 200 MR
S 200 M
S 200 M
S 200 P
S 200 S
S 200
UC
Series
Characteristics
B,C,D, B,C,D, B,C,D, B,C,D, B,C,D,
B,C, K, Z K B,C
K,Z K,Z K,Z K,Z K,Z
Breaking [kA]
capacity
Reference Nr. Ue[V]
standard poles
IEC/EN 60898 Icn 230/400 6 10 10 25 15 15 6
IEC/EN Icu 1, 133 20 25 40 25 25
60947-2 1P+N 230 10 15 25 15 15 15
Alternating 253
current
2, 3, 4 230 20 25 10 *17/6 *18 40 25 25
400 10 15 25 15 15 15
440 10 15 10 *17/6 *18
2, 3, 4 500
690
Ics 1, 133 15 18.7 *8 20 18.7 18.7
1P+N 230 7.5 11.2 *8 12.5 11.2 7.5
253 7.5 *18
7.5 *17/6 *18
11.2 *17
2, 3, 4 230 15 18.7 *8 20 18.7 18.7
400 7.5 11.2 *8 12.5 11.2 7.5
440 7.5 *18
7.5 11.2 *8 7.5 *17/6 *18
11.2 *17
2, 3, 4 500
690
IEC/EN Icu 1, 24 20
60947-2 1P+N 60 10 10 15 10 10
Direct current 125
T=I/R≤5ms
220 10
for
all series, 250
except S280 2 48 20
UC and 125 10 10 15 10 10
S800S-UC, 250
where
440 10
T=I/R<15ms
500
800
3,4 375
500
750
1200
1
—
Miniature circuit-breakers
Selection table
SU 200 MR
S 200 UDC
SU 200 M
SN 201 M
80-100A
SN 201 L
S200CM
S200CT
S200CL
SN 201
S200C
S200
C,Z K C,Z K K K,Z C B,C B,C B,C,D B,C B,C B,C B,C
3 4.5 4.5 6 6 10 10 6
20
15 15 15 15 15 6
20
15 15 15 15 15 6
10
11.25 11.25 7.5 7.5 6
7.5 *18
11.2 *17
10
11.25 11.25 7.5 7.5 6
7.5 *18
11.2 *17
15 15 10 10
15 15 10 10
1/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
Miniature circuit-breakers
Selection table
S 200 MR
S 200 M
S 200 M
S 200 P
S 200 S
S 200
UC
Series
Characteristics
B,C,D, B,C,D, B,C,D, B,C,D, B,C,D,
B,C, K, Z K B,C
K,Z K,Z K,Z K,Z K,Z
IEC/EN Ics 1, 24 20
60947-2 1P+N 60 10 10 15 10 10
Direct current 125
T=I/R≤5ms
220 10
for
all series, 250
except S280 2 48 20
UC and 125 10 10 15 10 10
S800S-UC, 250
where
440 10
T=I/R<15ms
500
800
3,4 375
500
750
1200
UL 1077/ Int. 1, 120 10 *16 10 10 10
C22.2 cap. 1P+N 240 10 10
No 235 277 6 *16 6 6 10 10 10 10
Alternating
2, 3, 4 240 10 *16 10 10 10
current
480
6 *16 6 6 10 6 6 10
Y/277
UL 1077/ Int. 1, 60 10 *16 10
C22.2 cap. 1P+N 125
No 235 250 10
Direct current
2, 3, 4 125 10
250
500 10
UL 489/ C22.2 Int. 1 240
No 5 cap. 277
Alternating 2, 3, 4 240
current
480
Y/277
UL 489/ C22.2 Int. 1 48
No 5 cap. 60
Direct current 125
2 96
125
250
1
—
Miniature circuit-breakers
Selection table
SU 200 MR
S 200 UDC
SU 200 M
SN 201 M
80-100A
SN 201 L
S200CM
S200CT
S200CL
SN 201
S200C
S200
C,Z K C,Z K K K,Z C B,C B,C B,C,D B,C B,C B,C B,C
15 15 10 10
15 15 10 10
10 10 10
10 10 10 *19
10 10 10
10 10 10 *19
10 10 10 10
14
14 *17
10 10 10 10
14 *15
14 *15 *17
1/12 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High performance circuit-breakers
Selection table
S 750 DR
S800N
S800C
S800S
S 700
Series
Characteristics E selective, E selective,
B,C,D K KM UCB UCK B,C,D B,C,D,K
K selective K selective
Rated current [A] 16 ≤ 10 ≤ 0.5 ≤ 0.5 ≤ 20 ≤ 0.5 ≤ 0.5 ≤ 6≤ 10 ≤
In In In In In In In In In
≤ 63 ≤ 100 ≤ 125 ≤ 125 ≤ 80 ≤ 125 ≤ 125 ≤ 125 ≤ 125
Breaking [kA]
capacity
Reference Nr. Ue[V]
standard poles
IEC/EN 60898 Icn 230/400 25 *9 25 *20 20 *20 15
IEC/EN Icu 1, 133
60947-2 1P+N 230 25
Alternating 240 50 50 50 *6 36 25
current
253
254 30 30 30 *6 20 15
15 (up to 80 A) 15 (up to 80 A)
289 10
10 (100...125 A) 10 (100...125 A)
400 6 (up to 80 A) 6 (up to 80 A)
6 *6 4.5
4.5 (100…125 A) 4.5 (100…125 A)
580
2, 3, 4 230
400 25
415 50 50 50 *6 36 25
440 30 30 30 *6 20 15
500 15 (up to 80 A) 15 (up to 80 A)
10 (100...125 A) 10 (100...125 A)
580 10
690 6 (up to 80 A) 6 (up to 80 A)
4.5
4.5 (100…125 A) 4.5 (100…125 A)
1000
Ics 1, 133
1P+N 230 12.5 12.5 *9
240 40 40 30 18
253
254 22.5 (up to 80 A) 22.5 (up to 80 A) 15 (up to 80 A)
22.5 10
15 (100…125 A) 15 (100…125 A) 10 (100…125 A
11 (up to 80 A) 11 (up to 80 A) 8 (up to 80 A)
289
5 (100...125 A) 5 (100...125 A) 5 (100...125 A
400 4 (up to 80 A) 4 (up to 80 A)
4 3
3 (100 … 125 A) 3 (100 … 125 A)
580
2, 3, 4 230
400 12.5 12.5 *9 40 40
415 40 *6 30 18
440 22.5 (up to 80 A) 22.5 (up to 80 A)
15
15 (100 ... 125 A) 15 (100 ... 125 A)
500 11 (up to 80 A) 8 (up to 80 A)
5 (100...125 A) 5 (100...125 A)
690 4 *3 4 *3 4 3
1000
1
—
High performance circuit-breakers
Selection table
S800PV-
S800HV
S800UP
S804U-
S804U-
S800U
S800B
UCZ
PVS
SP
B, C, D, K C, K Z, K Z, K UCZ PVS PV-SP
10 ≤ 5≤
32 ≤ C: 10 ≤ In ≤ 32
In 20-30 10-80 5 In
In ≤ 125 K: 0.5 ≤ In ≤ 125
≤ 100 ≤ 125
10
16
30 30
16
50 50
1.5 (0.5 … 5 A)
4 (6 … 63 A)
3 (80 … 125 A)
10
25 25
1.5 (0.5 … 5 A)
2.5 (6 … 63 A)
2 (80 … 125 A)
10
40 40
1.5 (0.5 … 5 A)
2.5 (6 … 63 A)
2 (80 … 125 A)
—
High performance circuit-breakers
Selection table
S 750 DR
S800N
S800C
S800S
S 700
Series
Characteristics E selective, E selective,
B,C,D K KM UCB UCK B,C,D B,C,D,K
K selective K selective
Rated current [A]
16 ≤ 10 ≤ 0.5 ≤ 0.5 ≤ 20 ≤ 0.5 ≤ 0.5 ≤ 6≤ 10 ≤
In In In In In In In In In
≤ 63 ≤ 100 ≤ 125 ≤ 125 ≤ 80 ≤ 125 ≤ 125 ≤ 125 ≤ 125
Breaking [kA]
capacity
Reference Nr. Ue[V]
standard poles
IEC/EN Icu 1, 24
60947-2 1P+N 60
Direct current 75
T=I/R≤5ms
125 30 30 20 10
for
all series, 220
except S280 250 50 50
UC and 2 48
S800S-UC, 125
where
150
T=I/R<15ms
250 30 30 20 10
440
500 50 50
800
3,4 225
300
375 30 *6 30 *6 30 *6 20 *6 10 *6
500 30 *7 30 *7 20 *7 10 *7
750 50 *6 50 *6
50 (63 ... 125 A) *7 50 (63 ... 125 A) *7
1000 50 (10 ... 50 A) *7 50 (10 ... 50 A) *7
1200
*1 only up to 40 A; 10 kA up to 50/63 A *9 relevant product standard: E DIN VDE *13 > 25 A *21 for S804U-UCZ only
*2 only for “D” characteristic 0645 *14 char. B, C *22 for S804U-PVS only
*3 values are not for all rated currents (based on IEC/EN 60898-1 *15 only 2 poles (connection in series)
*5 1500 V DC for 4P and IEC/EN 60947-2) *16 UL 1077 only
*6 3 poles *10 by 250 V DC 1-pole, 600 *17 ≤ 40 A
*7 4 poles V 3- and 4-pole *18 > 40 A
*8 max. values. Detailed *11 by 600 V DC 2-pole *19 ≤ 35 A
1
—
High performance circuit-breakers
Selection table
S800PV-
S800HV
S800UP
S804U-
S804U-
S800U
S800B
UCZ
PVS
SP
B, C, D, K C, K Z, K Z, K UCZ PVS PV-SP
10 ≤ 5≤
32 ≤ C: 10 ≤ In ≤ 32
In 20-30 10-80 5 In
In ≤ 125 K: 0.5 ≤ In ≤ 125
≤ 100 ≤ 125
10
10
5
10 *6
10 *7
5 *5
1/16 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High performance circuit-breakers
Selection table
S 750 DR
S800N
S800C
S800S
S 700
Series
Characteristics E selective, E selective,
B, C, D K KM UCB UCK B, C, D B, C, D, K
K selective K selective*9
Rated current [A] 16 ≤ 10 ≤ 0.5 ≤ 0.5 ≤ 20 ≤ 0.5 ≤ 0.5 ≤ 6≤ 10 ≤
In In In In In In In In In
≤ 63 ≤ 100 ≤ 125 ≤ 125 ≤ 80 ≤ 125 ≤ 125 ≤ 125 ≤ 125
IEC/EN Ics 1, 24
60947-2 1P+N 60
Direct current 125 30 30 20 10
T=I/R≤5ms 220
for 250 50 50
all series, 2 48
except S280 125
UC and
250 30 30 20 10
S800S-UC,
440
where
500 50 50
T=I/R<15ms
800
3,4 375 30 *6 30 *6 30 *6 20 *6 10 *6
500 30 *7 30 *7 20 *7 10 *7
750 50 *6 50 *6
50 (63 ... 125 A) *7 50 (63 ... 125 A) *7
1000 50 (10 ... 50 A) *7 50 (10 ... 50 A) *7
1200
UL 1077/ Int. 1, 120
C22.2 cap. 1P+N 240 30 30
20 (≤ 100 A)
No 235 (0.5...63 A) (0.5...63 A)
Alternating 277 14 14
current (0.5...63 A) (0.5...63 A)
347 6 (0.5...63 A) 6 (0.5...63 A) 10 (≤ 100 A)
2, 3, 4 240
480 14 (0.5... 14 (0.5...
10 (≤100 A)
Y/277 63 A) *27 63 A) *27
600Y/347 6 6
(0.5...63 A) (0.5...63 A)
UL 1077/ Int. 1, 60
C22.2 cap. 1P+N 125 10 (≤ 100 A)
No 235 250
Direct current 2, 3, 4 125
250 10 (2P,
≤ 100 A)
375 10 (3P,
≤ 100 A)
500 10 (4P,
≤ 100 A)
UL 489/ C22.2 Int. 1 240
No 5 cap. 277
Alternating 2, 3, 4 240
current 480
Y/277
UL 489/ C22.2 Int. 1 60
No 5 cap. 2 125
Direct current
4 600
UL489B 4 1000
Direct current
*1 only up to 40 A; 10 kA up to 50/63 A *6 3 poles *9 relevantproduct standard: *10 by 250 V DC 1-pole, 600 V
*2 only for “D” characteristic *7 4 poles E DIN VDE 0645 (based on 3- and 4-pole
*3 values are not for all rated currents *8 max. values. Detailed IEC/EN 60898-1 and IEC/EN 60947-2) *11 by 600 V DC 2-pole
*5 1500 V DC for 4P values on page 2/12 *12 ≤ 25 A
1/17
1
—
High performance circuit-breakers
Selection table
S800PV-
S800HV
S800UP
S804U-
S804U-
S800U
S800B
UCZ
PVS
SP
B, C, D, K C, K Z, K Z, K UCZ PVS PV-SP
10 ≤ 5≤
32 ≤ C: 10 ≤ In ≤ 32
In 20-30 10-80 5 In
In ≤ 125 K: 6 ≤ In ≤ 125
≤ 100 ≤ 125
5 *5
30
25
50
25
10
*13 > 25 A *18 > 40 A *24 by 150V DC 2-pole *28 P, 10 ... 32 A - only valid with
3
*15 only 2 poles (connection in series) *19 ≤ 35 A *25 by 225V DC 3-pole XT2L 125 TMF 35-400
*16 UL 1077 only *20 10-80 A *26 by 300V DC 4-pole
*17 ≤ 40 A *23 by 75V DC 1-pole *27 certification 50A ongoing
1/18 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCB S 200. The details make the difference
A range designed to ensure efficiency and protection
Quick identification
thanks to laser printed
EAN marking.
Contact position
indication
Captive screws:
don’t loose what’s Whatever your
important for you. application need is
applicable with a wide
range of accessories.
1/19
1
Contact position indication Approvals printed on the dome Housing material
All System pro M compact® MCBs are S 200 MCBs comply to IEC/EN 60898-1 By using the state-of-the-art housing
suited with a contact position and IEC/EN 60947-2 and carry all material, ABB is taking care of the
indication (CPI) on the toggle. You can relevant approval marks for each environment. With the latest
easily identify, if the MCB is in the ON market and segment they are destined generation of thermoplastics it’s
or the OFF position – easy and safe to. The certification markings are also possible to recycle the MCBs –
maintenance work is possible. printed on the dome of the MCB. Thus especially the thermoplastic housing-
make it possible to see the markings material can be re-used. By using the
also in the mounted position. For latest generation of thermoplastics
control and acceptance procedure – the material stability of all System pro
certification marks visible on fitted M compact® MCBs is improved. S200
devices on the dome. are 100% free of halogens – no
environmental pollution.
—
MCBs
S 200 technical features
S 200 S 200 M
General Standards IEC/EN 60898-1, IEC/EN 60898-1,
Data IEC/EN 60947-2 IEC/EN 60947-2
UL 1077 UL 1077, CSA 22.2
No. 235
Poles 1P, 2P, 3P, 4P, 1P+N, 3P+N
Max. power frequency recovery voltage (Umax) V 1P: 253 V AC; 1P+N: 253 V AC; 2P...4P: 462 V AC;
3P+N: 462 V AC; 1P: 72 V DC; 2P: 125 V DC
Rated impulse withstand voltage Uimp. (1.2/50µs) kV 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m)
Dielectric test voltage kV 2 kV (50 / 60Hz, 1 min.)
Reference temperature for tripping characteristics °C B, C, D: 55°C; K, Z: 20°C
Electrical endurance ops. In < 32A: 20,000 ops (AC),
In ≥ 32A: 10,000 ops. (AC); 1,000 ops. (DC);
(1 cycle 2s - ON, 13s - OFF, In ≤ 32A),
(1 cyle 2s - ON, 28s - OFF, In > 32A)
Note:
* Only acc. to IEC/EN 60898-1
1/21
1
—
MCBs
S 200 technical features
1P: 253 V AC, 220 V DC 1P: 230 V AC; 1P: 230 V AC 1P: 230 V AC 1P: 230 V AC --
2...4P: 440 V AC, 440 1P+N: 230 V AC; 2...4P: 400 V AC 2...4P: 400 V AC 2...4P: 400
V DC 2...4P: 400 V AC; V AC
3P+N: 400 V AC
1P: 266 V AC, 250 V DC 1P: 253 V AC; 1P: 253 V AC 1P: 253/440 V AC; 1P: 253 V AC --
2...4P: 462 V AC, 500 1P+N: 253 V AC; 2...4P: 440 V AC 2...4P: 440 V AC 2...4P: 440
V DC 2P...4P: 440 V AC; V AC
3P+N: 440 V AC;
1P: 72 V DC; 2P: 125
V DC
12 V AC 12 V AC --
≤ 40 A: 10 kA AC; 10 ≤ 25 A: 25 kA 15 kA 10 kA 15 kA --
kA DC ≥ 32 A: 15 kA
> 40 A: 6 kA AC; 10 kA
DC
≤ 40 A: 7,5 kA AC; 10 ≤ 25 A: 12.5 kA ≤ 40 A: 11.2 kA; 7.5 kA ≤ 40 A: 11.2 kA; --
kA DC ≤ 32…40 A: 11.2 kA > 40 A: 7.5 kA > 40 A: 7.5 kA
> 40 A: 6 kA(AC; 10 50, 63 A: 7.5 kA AC; (AC);
kA DC
--
--
B, C: 55 °C; K, Z: 20 °C 20 °C C, K, Z: 20°C 20 °C --
In < 32A: 20,000 ops In < 32A: 20,000 ops In < 25A: 20,000 In < 25A: --
(AC), (AC), In ≥ 32A: 10,000 ops (AC), 20,000 ops
In ≥ 32A: 10,000 ops. ops. (AC); In ≥ 25A: 10,000 (AC),
(AC); 1,000 ops. (DC); ops. (AC); In ≥ 25A:
1,500 ops. (DC); (1 cycle 2s - ON, 13s - 10,000 ops.
OFF, (AC);
In ≤ 32A), (1 cyle 2s -
ON, 28s - OFF, In ≥ 32A)
1/22 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 technical features
S 200 S 200 M
Data acc. Rated voltage V 480Y / 277 V AC; 480Y / 277 V AC;
to UL /
CSA
S 200
1P: 60 V DC; 1P: 60 V DC;
2P…4P: 110 V DC 2P…4P: 125 V DC
Vibration resistance acc. to IEC/EN 60068-2-6 5g - 20 cycles at 5…150…5 Hz with load 0.8In
Environmental conditions (damp heat) °C/ 28 cycles with 55°C/90-96% and 25°C/95-100%
acc. to IEC/EN 60068-2-30 RH
Ambient temperature °C -25 … +55°C
Storage temperature °C -40 … +70°C
Note:
* Also fulfilling the requirement acc. to the protection degree IPXXB
** Only with accessory: IP20 terminal clip
1/23
1
—
MCBs
S 200 technical features
—
MCBs
S 200 technical features
S 200 S 200 M
Installa- Terminal Failsafe bi-directional cylinder-lift terminal
tion
Cross-section of conductors *1 Solid / mm 2 35 mm 2 / 35 mm 2
(top / bottom) Stranded
Flexible mm 2 25 mm 2 / 25 mm 2
*1 rior to connection of aluminium conductors (>= 4 mm 2) ensure that their contact points are cleaned,
P
brushed and coated with grease.
Connection of aluminium conductors is not specifically approved by third party.
All approvals according to the product standards are carried out with copper conductors.
*2 N m-values acc. IEC / in-lbs.-values acc. UL
*3 1 ... 4 mm² (rigid or flexible wires without end sleeves); 1 … 2.5 mm² (flexible wires with end sleeves)
1/25
1
—
MCBs
S 200 technical features
—
MCBs
S 200 series B characteristic
S 200 B characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for people and large length of cables in TN and IT systems.
Applications: residential, commercial and industrial.
Standard: IEC/EN 60898-1, IEC/EN 60947-2
Icn=6 kA
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/27
1
—
MCBs
S 200 series B characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
S 203 NA *2 suitable for flow-type heaters 18 kW
1/28 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series C characteristic
S 200 C characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for resistive and inductive loads with low inrush current.
Applications: residential, commercial and industrial.
Standard: IEC/EN 60898-1, IEC/EN 60947-2
Icn=6 kA
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/29
1
—
MCBs
S 200 series C characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/30 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series C characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/31
1
—
MCBs
S 200 series D characteristic
S 200 D characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
Applications: residential, commercial and industrial.
Standard: IEC/EN 60898-1, IEC/EN 60947-2
Icn=6 kA
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/32 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series D characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/33
1
—
MCBs
S 200 series D characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/34 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series K characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/35
1
—
MCBs
S 200 series K characteristic
—
MCBs
S 200 series K characteristic
1
—
MCBs
S 200 series Z characteristic
S 200 Z characteristic
Function: protection and control of the electronic circuits against lower and long
duration overloads and short-circuits.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
Icu=10 kA
—
MCBs
S 200 series Z characteristic
1
—
MCBs
S 200 series Z characteristic
—
MCBs
S 200 series M-B characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/41
1
—
MCBs
S 200 series M-B characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/42 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series M-C characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/43
1
—
MCBs
S 200 series M-C characteristic
—
MCBs
S 200 series M-C characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/45
1
—
MCBs
S 200 series M-D characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/46 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series M-D characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/47
1
—
MCBs
S 200 series M-D characteristic
*1 suitable for flow-type heaters 12 kW *3 suitable for flow-type heaters 21, 24 and 27 kW
*2 suitable for flow-type heaters 18 kW
1/48 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 series M-K characteristic
1
—
MCBs
S 200 series M-K characteristic
—
MCBs
S 200 series M-K characteristic
1
—
MCBs
S 200 series M-Z characteristic
—
MCBs
S 200 series M-Z characteristic
1
—
MCBs
S 200 series M-Z characteristic
—
MCBs
Supplementary protector S 200 MR series, 10kA
1
—
MCBs
Supplementary protector S 200 MR series, 10kA
—
MCBs
S 200 series M UC B characteristic
Universal current range
S 200 M UC B characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for people and big length cables in TN and IT systems; version dedicated to
application
in direct current circuits for voltages up to 220 V DC 1 pole and 440 V DC 2, 3 and 4 poles.
Applications: Industrial.
Standard: IEC/EN 60898-2, IEC/EN 60947-2, UL1077, CSA 22.2 No. 235
(for DC applications, please note polarity of device)
Icu=10 kA
1
—
MCBs
S 200 series M UC B characteristic
Universal current range
—
MCBs
S 200 series M UC C characteristic
Universal current range
S 200 M UC C characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for people and big length cables in TN and IT systems; version dedicated to
application
in direct current circuits for voltages up to 220 V DC 1 pole and 440 V DC 2, 3 and 4 poles.
Applications: Industrial.
Standard: IEC/EN 60898-2, IEC/EN 60947-2, UL1077, CSA 22.2 No. 235
(for DC applications, please note polarity of device)
Icu=10 kA
1
—
MCBs
S 200 series M UC C characteristic
Universal current range
—
MCBs
S 200 series M UC – Universal current range K characteristic
S 200 M UC K characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for people and big length cables in TN and IT systems; version dedicated to
application
in direct current circuits for voltages up to 220 V DC 1 pole and 440 V DC 2, 3 and 4 poles.
Applications: Industrial.
Standard: IEC/EN 60947-2, UL1077, CSA 22.2 No. 235
(for DC applications, please note polarity of device)
Icu=10 kA
1
—
MCBs
S 200 series M UC – Universal current range K characteristic
—
MCBs
S 200 series M UC – Universal current range K characteristic
1
—
MCBs
S 200 series M UC – Universal current range Z characteristic
S 200 M UC Z characteristic
Function: protection and control of the circuits against overloads and short-circuits;
protection for people and big length cables in TN and IT systems; version dedicated to
application
in direct current circuits for voltages up to 220 V DC 1 pole and 440 V DC 2, 3 and 4 poles.
Applications: Industrial.
Standard: IEC/EN 60947-2, UL1077, CSA 22.2 No. 235
(for DC applications, please note polarity of device)
Icu=10 kA
—
MCBs
S 200 series M UC – Universal current range Z characteristic
1
—
MCBs
S 200 series P-B characteristic
—
MCBs
S 200 series P-B characteristic
1
—
MCBs
S 200 series P-B characteristic
—
MCBs
S 200 series P-C characteristic
1
—
MCBs
S 200 series P-C characteristic
—
MCBs
S 200 series P-D characteristic
1
—
MCBs
S 200 series P-D characteristic
—
MCBs
S 200 series P-D characteristic
1
—
MCBs
S 200 series P-K characteristic
—
MCBs
S 200 series P-K characteristic
1
—
MCBs
S 200 series P-K characteristic
—
MCBs
S 200 series P-K characteristic
1
—
MCBs
S 200 series P-Z characteristic
—
MCBs
S 200 series P-Z characteristic
1
—
MCBs
S 200 series P-Z characteristic
—
MCBs
S 200 series S - screwless range B and C characteristics
1
—
MCBs
SU 200 M series technical characteristic
General Data
Standards UL 489, CSA 22.2 No. 5, IEC/EN 60947-2
Poles 1P, 2P, 3P, 4P
Tripping characteristics C, K, Z
Rated current In 0.2 - 63 A
Rated frequency f 50 / 60 Hz, DC (0 Hz)
Rated insulation voltage Ui acc. to IEC/EN 440 V AC (phase to phase)
60664-1
Overvoltage category III
Pollution degree 3
IEC/EN 60947-2
Rated operational voltage Ue 1P: 230 V AC; 2P, 3P, 4P: 400 V AC
Max. power frequency recovery voltage Umax AC 1P: 253 V AC; 2P, 3P, 4P: 440 V AC
Min. operating voltage 12 V AC, 12 V DC
Rated ultimate short-circuit breaking capacity 15 kA
Icu
Rated service short-circuit breaking capacity Ics ≤ 40 A: 11.25 kA
> 40 A: 7.5 kA
Rated impulse withstand voltage Uimp 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m)
(1.2/50μs)
Dielectric test voltage 2 kV (50 / 60Hz, 1 min.)
Reference temperature for tripping 30 °C
characteristics
Electrical endurance In < 30 A: 20,000 ops (AC), In ≥ 30 A: 10,000 ops. (AC);
1 cycle (2 s - ON, 13 s - OFF, In ≤ 32 A), 1 cycle (2 s - ON,
28 s - OFF, In > 32 A)
UL / CSA
Rated voltage AC 1P: 277 V AC up to 40 A for C, Z char.,
AC 277 V AC up to 35 A for K char., 240 V AC
AC 2P, 3P, 4P: 480 Y / 277 V AC up to 40 A for C, Z char.,
AC 480 Y / 277 V AC up to 35 A for K char., 240 V AC
DC 1P: 48 V DC; 2P: 96 V DC (2p in series)
Rated interrupting capacity acc. to UL 1077 –
Short-circuit current rating acc. to UL 489 10 kA
Application –
Reference temperature for tripping 40 °C
characteristics
Electrical endurance 6,000 ops (AC), 6,000 ops. (DC); 1 cycle (1 s - ON, 9 s - OFF)
1/82 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
SU 200 M series technical characteristic
Mechanical data
Housing Insulation group II, RAL 7035
Toggle Insulation group II, black, sealable
Contact position indication Real CPI (green OFF / red ON)
Protection degree acc. to DIN EN 60529 IP20*, IP40 in enclosure with cover
Mechanical endurance 20,000 ops.
Shock resistance acc. to IEC/EN 60068-2-27 25 g - 2 shocks - 13 ms
Vibration resistance acc. to IEC/EN 60068-2-6 5g - 20 cycles at 5…150…5 Hz with load 0.8 In
Environmental conditions (damp heat cyclic) 28 cycles with 55°C/90-96% and 25°C/95-100%
acc. to IEC/EN 60068-2-30
Ambient temperature -25 … +55°C
Storage temperature -40 ... +70 °C
Installation
Terminal Failsafe bi-directional cylinder-lift terminal
Cross-section of conductors (top/bottom) solid, stranded: 35 mm² / 35 mm²
flexible: 25 mm 2 / 25 mm 2
18 – 4 AWG
Cross-section of busbars (top/bottom) 10 mm² / 10 mm²
18 – 8 AWG
Torque 2.8 Nm
AWG 18-16: 13.3 in-lbs.
AWG 14-10: 17.7 in-lbs.
AWG 8-4: 39.8 in-lbs.
Screwdriver No. 2 Pozidrive
Mounting On DIN rail 35 mm acc. to EN 60715 by fast clip
Mounting position any
Supply optional
Dimensions and weight
Mounting dimensions acc. to DIN 43880 Mounting dimension 3
Pole dimensions (H x D x W) 111 x 69 x 17.5 mm
Pole weight approx. 125 g
Combination with auxiliary elements
Auxiliary contact Yes
Signal contact Yes
Shunt trip Yes
1
—
MCBs
SU 200 M series C characteristic
—
MCBs
SU 200 M series C characteristic
1
—
MCBs
SU 200 M series C characteristic
—
MCBs
SU 200 M series K characteristic
1
—
MCBs
SU 200 M series K characteristic
—
MCBs
SU 200 M series K characteristic
1
—
MCBs
SU 200 M series K characteristic
—
MCBs
SU 200 M series Z characteristic
1
—
MCBs
SU 200 M series Z characteristic
—
MCBs
SU 200 M series Z characteristic
1
—
MCBs
Circuit breaker SU 200 MR series, 10kA
The SU200 MR is a high-performance circuit breaker with ring cable lug connections
conforming to UL 489; CSA 22.2. No. 5 and IEC/EN 60947-2 standards. The integrated captive
connecting screws simplify the connection of electric lines, provides extra protection and
saves time.
—
MCBs
Circuit breaker SU 200 MR series, 10kA
1
—
MCBs
S 200 series UDC - Universal current range, UL, K characteristic
—
MCBs
S 200 series UDC - Universal current range, UL, K characteristic
1
—
MCBs
S 200 series UDC - Universal current range, UL, Z characteristic
—
MCB SN 201. The details make the difference
A range designed to ensure efficiency
and protection
Easy identification of
the product and highly
Quick identification resistant laser marking.
thanks to laser printed
EAN marking.
Contact position
indicator on the
level, with Green/
Red indicator
A wide range of
accessories is
available
1P+N protection
in only one module
1/99
1
Space for insulated screwdrivers: the larger neutral hole Two bistable fixing devices for maximum ease of use: due to
allows the use of an insulated screwdriver to tighten the larger size of the DIN rail fixing system, made with 2 bistable
screws of both wire terminals, ensuring maximum safety of fixing devices, the same screwdriver used for tightening the
the operation. terminals can also be used for assembling and
disassembling the device.
With the practical label carrier fitted in the SN201 circuit- The SN201 fully integrates with the range of System pro M
breakers you can give maximum visibility to the information compact® miniature circuit-breakers, sharing the wide
relating to the protected loads. selection of accessories available through a dedicated
interface (half module), which also can be used as auxiliary
contact.
1/100 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
Miniature circuit-breakers
SN 201 series - 1P+N in one module housing
*1 SN201 and SN201M series in B and D characteristic are available for rated current In ≥ 6 A
1/101
1
—
Miniature circuit-breakers
SN 201 series - 1P+N in one module housing
—
MCBs
SN 201 L series B and C characteristic
SN 201 L - B characteristic
Function: overload and short-circuit protection of circuits in final distribution; protection
of long cable lengths in TN and IT systems.
Applications: residential.
Standard: IEC/EN 60898
Icn: 4.5 kA
SN 201 L - C characteristic
Function: overload and short-circuit protection of circuits in final distribution; protection of
resistive and inductive loads with low inrush current.
Applications: residential.
Standard: IEC/EN 60898
Icn: 4.5 kA
1
—
MCBs
SN 201 series B and C characteristic
SN 201 - B characteristic
Function: overload and short-circuits protection of circuits in final distribution; protection of
long cable lengths in TN and IT systems.
Applications: residential and commercial.
Standard: IEC/EN 60898
Icn: 6 kA
—
MCBs
SN 201 series D characteristic
SN 201 - D characteristic
Function: protection and control of the circuits against overloads and short-circuits in final
distribution; protection for circuits which supply loads with high inrush current at the circuit
closing.
Applications: residential and commercial.
Standard: IEC/EN 60898
Icn: 6 kA
1
—
MCBs
SN 201 M series B and C characteristic
SN 201 M - B characteristic
Function: overloads and short-circuit protection of circuits in final distribution; protection
of long cable lengths in TN and IT systems.
Applications: residential and commercial.
Standard: IEC/EN 60898
Icn: 10 kA
—
S200C Compact MCBs
Save up to 50% more of space
in the installation
Easy to install
1
—
S200C series
One-sight overview
—
MCBs
S2011C - Technical features
S2011C
Standards IEC/EN 60898-1
Electrical features
Number of poles 1P+1P
Number od modules 1M
Tripping Characteristic B, C
Rated current In A 2 ≤ In ≤ 20
Rated voltage Ue V 230/240
Insulation voltage Ui V 500 V AC
Overvoltage category III
Pollution degree 2
Rated frequency Hz 50/60
Min operating voltage V 12
Max operating voltage V 264
Rated breaking capacity acc. to IEC/EN 60898-1 Icn A 6000
“Rated breaking capacity acc. to IEC/EN 60947-2 ultimate Icu kA 6
(only referring to short circuit test)”
service Ics kA 6
Rated breaking capacity Icn1 acc. to IEC/EN 60898-1 Icn1 A 6000
“Rated breaking capacity acc. to IEC/EN 60947-2 in DC ultimate Icu kA 6 kA @ 48 VDC
(only referring to short circuit test, poles connected in
series, tc 4ms)”
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 1 min.)
Thermomagnetic release - characteristic B: 3 In ≤ Im ≤ 5 g
In
C: 5 In ≤ Im ≤ g
10 In
Energy limiting class 3
Mechanical features
Housing Insulation group I, RAL 7035
Toggle Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Electrical life operations 10000
Mechanical life operations 20000
Protection degree acc. to EN 60529 housing IP40
terminals IP20
Shock resistance acc. to IEC/EN 60068-2-27 40 g (x,y,z) - 18 shocks - 5ms half sinusoidal
Vibration resistance acc. to IEC/EN 60068-2-6 0.35 mm or 5g - 20 cycles at 5…150…5 Hz
Environmental conditions (damp heat) acc. to IEC/EN
60068-2-30 °C/RH 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Reference temperature for setting of thermal element °C 30
Ambient temperature (with daily average ≤ +35 °C) °C -25…+55
Storage temperature °C -40…+70
Installation
Fail-safe terminals, bi-directional cylinder-lift terminal (shock
Terminal type top / bottom protected)
Terminal size for cables top / bottom mm2 10 flexible /16 rigid top & bottom
Terminal size for busbars top / bottom mm2 10/10
Tightening torque top / bottom Nm 3
Stripping length of the cable mm 12
Mounting on DIN rail EN 60715 (35 mm) by means of mounting clip
Mounting position Vertical & Horizontal
Supply from Top/Bottom terminals
Dimensions and weight
Dimensions (H×D×W) mm 86×70×17.8 mm
Weight g 160
Combinationwithauxiliary elements
Combinable with accessories and auxiliaries YES, G2C series
1/109
1
—
MCBs
S202C - Technical features
S202C S202TC
S202C T S202C L S202C S202C M S202TC
Standards IEC/EN 60898-1
Electrical features
Number of poles 2P 2P 2P 2P 2P
Number od modules 1M 1M 1M 1M 1M
Tripping Characteristic C B, C B, C B, C B, C
Rated current In A 2 ≤ In ≤ 40 2 ≤ In ≤ 40 2 ≤ In ≤ 40 2 ≤ In ≤ 32 2 ≤ In ≤ 32
Rated voltage Ue V 400/415 400/415 400/415 230/240 400/415
Insulation voltage Ui V 500 V AC 500 V AC 500 V AC 500 V AC 500 V AC
Overvoltage category III III III III III
Pollution degree 2 2 2 2 2
Rated frequency Hz 50/60 50/60 50/60 50/60 50/60
Min operating voltage V 12 12 12 12 12
Max operating voltage V 440 440 440 264 440
Rated breaking capacity acc. to IEC/EN 60898-1 I cn A 3000 4500 6000 10000 6000
“Rated breaking capacity acc. to IEC/EN 60947-2 ultimate Icu kA 3 6 10 10 6
(only referring to short circuit test)”
service Ics kA 3 4.5 6 7.5 6
Rated breaking capacity Icn1 acc. to IEC/EN Icn1 A 3000 4500 6000 6000 6000
60898-1
“Rated breaking capacity acc. to IEC/EN ultimate Icu kA 3 kA @ 4.5 kA @ 6 kA @ - 6 kA @
60947-2 in DC (only referring to short circuit 110 VDC 110 VDC 110 VDC 110 VDC
test, poles connected in series, tc 4ms)”
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV 4 kV 4 kV 4 kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 2.5 kV (50 / 2.5 kV (50 / 2.5 kV (50 / 2.5 kV (50 /
60Hz, 1 min.) 60Hz, 1 min.) 60Hz, 1 min.) 60Hz, 1 min.) 60Hz, 1 min.)
Thermomagnetic release - characteristic B: 3 In ≤ Im ≤ g g g g
5 In
C: 5 In ≤ Im ≤ g g g g g
10 In
Energy limiting class 3
Mechanical features
Housing Insulation group I, RAL 7035
Toggle Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Electrical life operations 10000
Mechanical life operations 20000
Protection degree acc. to EN 60529 housing IP40
terminals IP20
Shock resistance acc. to IEC/EN 60068-2-27 40 g (x,y,z) - 18 shocks - 5 ms half sinusoidal
Vibration resistance acc. to IEC/EN 60068-2-6 0.35 mm or 5 g - 20 cycles at 5…150…5 Hz
Environmental conditions (damp heat) acc. to
IEC/EN 60068-2-30 °C/RH 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Reference temperature for setting of thermal
element °C 30
Ambient temperature (with daily average ≤ +35 °C) °C -25…+55
Storage temperature °C -40...+70
Installation
Terminal type top / bottom Fail-safe terminals, bi-directional cylinder-lift terminal (shock protected)
Terminal size for cables top / bottom mm2 10 flexible /16 rigid top & bottom
Terminal size for busbars top / bottom mm2 10/10
Tightening torque top / bottom Nm 3
Stripping length of the cable mm 12
Mounting on DIN rail EN 60715 (35 mm) by means of mounting clip
Mounting position Vertical & Horizontal
Supply from Top/Bottom terminals
Dimensions and weight
Dimensions (H×D×W) mm 86×70×17.8 mm
Weight g 160
Combinationwithauxiliary elements
Combinable with accessories and auxiliaries YES, G2C series
1/110 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S203C - Technical features
S203C
S203C T S203C L S203C
Standards IEC/EN 60898-1
Electrical features
Number of poles 3P 3P 3P
Number od modules 2M 2M 2M
Tripping Characteristic C B, C B, C
Rated current In A 2 ≤ In ≤ 32 2 ≤ In ≤ 32 2 ≤ In ≤ 32
Rated voltage Ue V 400/415 400/415 400/415
Insulation voltage Ui V 500 V AC 500 V AC 500 V AC
Overvoltage category III III III
Pollution degree 2 2 2
Rated frequency Hz 50/60 50/60 50/60
Min operating voltage V 12 12 12
Max operating voltage V 440 440 440
Rated breaking capacity acc. to IEC/EN 60898-1 Icn A 3000 4500 6000
“Rated breaking capacity acc. to IEC/EN 60947-2 ultimate Icu kA 3 6 6
(only referring to short circuit test)” service Ics kA 3 4.5 6
Rated breaking capacity Icn1 acc. to IEC/ Icn1 A 3000 4500 4500
EN 60898-1
“Rated breaking capacity acc. to IEC/EN 60947-2 ultimate Icu kA NA NA NA
in DC (only referring to short circuit test, poles
connected in series, tc 4ms)”
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV 4 kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 2.5 kV (50 / 60Hz, 2.5 kV (50 / 60Hz,
1 min.) 1 min.) 1 min.)
Thermomagnetic release - characteristic B: 3 In ≤ Im ≤ 5 In g g
C: 5 In ≤ Im ≤ 10 In g g g
Energy limiting class 3
Mechanical features
Housing Insulation group I, RAL 7035
Toggle Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Electrical life operations 10000
Mechanical life operations 20000
Protection degree acc. to EN 60529 housing IP40
terminals IP20
Shock resistance acc. to IEC/EN 60068-2-27 40 g (x,y,z) - 18 shocks - 5 ms half sinusoidal
Vibration resistance acc. to IEC/EN 60068-2-6 0.35 mm or 5 g - 20 cycles at 5…150…5 Hz
Environmental conditions (damp heat) acc. to
IEC/EN 60068-2-30 °C/RH 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Reference temperature for setting of thermal
element °C 30
Ambient temperature (with daily average ≤ +35 °C) °C -25…+55
Storage temperature °C -40…+70
Installation
Fail-safe terminals, bi-directional cylinder-lift terminal (shock
Terminal type top / bottom protected)
Terminal size for cables top / bottom mm2 10 flexible /16 rigid top & bottom
Terminal size for busbars top / bottom mm2 10/10
Tightening torque top / bottom Nm 3
Stripping length of the cable mm 12
Mounting on DIN rail EN 60715 (35 mm) by means of mounting clip
Mounting position Vertical & Horizontal
Supply from Top/Bottom terminals
Dimensions and weight
Dimensions (H×D×W) mm 86×70×35.6 mm
Weight g 320
Combinationwithauxiliary elements
Combinable with accessories and auxiliaries YES, G2C series
1/111
1
—
MCBs
S204C - Technical features
S204C
S204C T S204C L S204C
Standards IEC/EN 60898-1
Electrical features
Number of poles 4P 4P 4P
Number od modules 2M 2M 2M
Tripping Characteristic C B, C B, C
Rated current In A 2 ≤ In ≤ 32 2 ≤ In ≤ 32 2 ≤ In ≤ 32
Rated voltage Ue V 400/415 400/415 400/415
Insulation voltage Ui V 500 V AC 500 V AC 500 V AC
Overvoltage category III III III
Pollution degree 2 2 2
Rated frequency Hz 50/60 50/60 50/60
Min operating voltage V 12 12 12
Max operating voltage V 440 440 440
Rated breaking capacity acc. to IEC/EN 60898-1 I cn A 3000 4500 6000
“Rated breaking capacity acc. to IEC/EN ultimate Icu kA 3 6 6
60947-2 (only referring to short circuit test)” service Ics kA 3 4.5 6
Rated breaking capacity Icn1 acc. to IEC/EN Icn1 A 3000 4500 4500
60898-1
“Rated breaking capacity acc. to IEC/EN ultimate Icu kA 3kA @ 220 VDC 4.5kA @ 220 VDC 6kA @ 220 VDC
60947-2 in DC (only referring to short circuit
test, poles connected in series, tc 4ms)”
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV 4 kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 2.5 kV (50 / 60Hz, 2.5 kV (50 / 60Hz,
1 min.) 1 min.) 1 min.)
Thermomagnetic release - characteristic B: 3 In ≤ Im ≤ 5 In g g
C: 5 In ≤ Im ≤ 10 In g g g
Energy limiting class 3
Mechanical features
Housing Insulation group I, RAL 7035
Toggle Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Electrical life operations 10000
Mechanical life operations 20000
Protection degree acc. to EN 60529 housing IP40
terminals IP20
Shock resistance acc. to IEC/EN 60068-2-27 40 g (x,y,z) - 18 shocks - 5 ms half sinusoidal
Vibration resistance acc. to IEC/EN 60068-2-6 0.35 mm or 5 g - 20 cycles at 5…150…5 Hz
Environmental conditions (damp heat) acc. to
IEC/EN 60068-2-30 °C/RH 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Reference temperature for setting of thermal
element °C 30
Ambient temperature (with daily average ≤ +35 °C) °C -25…+55
Storage temperature °C -40…+70
Installation
Terminal type top / bottom Fail-safe terminals, bi-directional cylinder-lift terminal (shock protected)
Terminal size for cables top / bottom mm2 10 flexible /16 rigid top & bottom
Terminal size for busbars top / bottom mm2 10/10
Tightening torque top / bottom Nm 3
Stripping length of the cable mm 12
Mounting on DIN rail EN 60715 (35 mm) by means of mounting clip
Mounting position Vertical & Horizontal
Supply from Top/Bottom terminals
Dimensions and weight
Dimensions (H×D×W) mm 86×70×35.6 mm
Weight g 320
Combinationwithauxiliary elements
Combinable with accessories and auxiliaries YES, G2C series
1/112 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S200C Compact MCBs - Ordering data
S2011C: 1P+1P in 1M
Function: protection and control of the circuits against overloads and short-circuits
Applications: residential, commercial
Standard: IEC/EN 60898-1
1
—
MCBs
S200C Compact MCBs - Ordering data
S202C: 2P in 1M
Function: protection and control of the circuits against overloads and short-circuits
Applications: residential, commercial
Standard: IEC/EN 60898-1
—
MCBs
S200C Compact MCBs - Ordering data
S202C: 2P in 1M
Function: protection and control of the circuits against overloads and short-circuits
Applications: residential, commercial
Standard: IEC/EN 60898-1
1
—
MCBs
S200C Compact MCBs - Ordering data
—
MCBs
S200C Compact MCBs - Ordering data
S203C: 3P in 2M
Function: protection and control of the circuits against overloads and short-circuits
Applications: residential, commercial, industrial
Standard: IEC/EN 60898-1
1
—
MCBs
S200C Compact MCBs - Ordering data
S204C: 4P in 2M
Function: protection and control of the circuits against overloads and short-circuits
Applications: residential, commercial, industrial
Standard: IEC/EN 60898-1
—
MCBs
S200C Compact MCBs - Accessories
Mounting:
on the left or right, up to 4 G2C units (On S203C accepted only on the left)
—
Performances
—
Ordering code
1
—
MCBs
S200C Compact MCBs - Busbars
—
Busbars
—
End Caps
—
Feeder Terminal
—
MCBs
S200C Compact MCBs - Drawings
—
S201C and S202C
2 3 4 5
B C
69.4
65.6
56.5
86
17.8
6 43.8
B C
1
—
MCBs
S200C Compact MCBs - Drawings
—
S203C and S204C
2 3 4 5
69.4
65.6
56.5
86
6 43.8
VOLUME
Critical to Quality Characteristic
AB
MASS MATERIAL SPECIFICATION FINISH SPECIFICATION UNITS LOCAL TIT
--- mm
UNLESS OTHERWISE SPECIFIED
MATERIAL DESCRIPTION SIZE ROOT NU
Linear and Geometry Tolerance: --- A3
ISO 2768-mK
1/122 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S200C Compact MCBs - Drawings
—
Auxiliary contact
1 2 3 4
Geometric Dimensioning & Tolerancing as per ASME Y14.5-2009
Part Must Conform to SI900000 Sec.4 Toxicity Procedure
86
A
65.86
56.5
43.8
49.8
B
31
48.7 8.7
Any unauthorized use, reproduction, distribution or disclosure to third parties is strictly forbidden.
ABB reserves all rights regarding intellectual Property Rights.
Copyright 2018 ABB. All rights reserved
DRAWING FILE M
SCT6-001-00ASSEMBLY1
DATE MODIFIED D
01-Mar-11 09:30:55 PM
Calculated for: CN# AP
D VOLUME
C#######
Critical to Qu
MASS MATERIAL SPECIFICATION FI
1
—
MCBs
S200C Compact MCBs - Additional technical features
—
Power loss
In 1P+1P 2P 3P 4P
(A) (W) (W) (W) (W)
2 2.2 2.2 3.3 4.4
4 2.7 2.7 4.0 5.4
6 3.0 3.0 4.6 6.1
10 3.3 3.3 4.9 6.6
13 3.8 3.8 NA NA
15 NA 3.9 NA NA
16 4.2 4.2 6.3 8.4
20 5.0 5.0 7.6 10.1
25 NA 6.2 9.3 12.4
32 NA 7.6 11.4 15.2
40 NA 8.9 NA NA
—
Influent of adjacent devices
Number of devices K
2 or 3 0.9
4 or 5 0.8
6 to 9 0.7
> 10 0.6
1/124 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S 200 80A-100A series technical features
S 200 80A-100A
General Data
Standards IEC/EN 60898-1, IEC/EN 60947-2
Poles 1P, 2P, 3P, 4P, 1P+N, 3P+N
Tripping characteristics B, C
Rated current In 80 A, 100 A
Rated frequency f 50/60 Hz
S 200 80-100A Rated insulation voltage Ui acc. to IEC/EN 440 V AC
60664-1 (VDE 0110-1)
Overvoltage category III
Pollution degree 2
IEC/EN 60898-1
Rated operational voltage Un 1P: 230/400 V AC; 1P+N: 230 V AC; 2P, 3P, 4P, 3P+N: 400 V AC
Max. power frequency recovery voltage Umax 1P: 253/440 V AC; 1P+N: 253 V AC; 2P, 3P, 4P, 3P+N: 440 V AC
Min. operating voltage 12 V AC
Rated short-circuit capacity Icn 6 kA
Rated impulse withstand voltage Uimp 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m)
(1.2/50µs)
Dielectrical test voltage 2 kV (50/60 Hz, 1 min.)
Reference temperature for tripping B, C: 30 °C
characteristics
Electrical endurance 10,000 ops. (AC); one cycle 2 s - ON, 28 s - OFF
IEC/EN 60947-2
Rated operational voltage Ue 1P, 1P+N: 230 V AC; 2P, 3P, 4P, 3P+N: 400 V AC
Max. power frequency recovery voltage Umax 1P, 1P+N: 253 V AC; 2P, 3P, 4P, 3P+N: 440 V AC
Min. operating voltage 12 V AC
Rated ultimate short-circuit breaking capacity Icu 6 kA
Rated service short-circuit breaking capacity Ics 6 kA
Rated impulse withstand voltage Uimp 4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m)
(1.2/50 µs)
Dielectrical test voltage 2 kV (50/60 Hz, 1 min.)
1/125
1
—
MCBs
S 200 80A-100A series technical features
—
MCBs
S 200 80A-100A
The miniature circuit breakers of the System pro M compact® series S 200 provide state-of-
the-art safety and comfort. They stand out due to their high performance and the wide
range of accessories and approvals.
The additional electrical currents 80 A and 100 A complement the current portfolio of the
System pro M compact® and offer maximum performance in a single module width.
S 203 80-100A NA
1/127
1
—
Notes
1/128 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
SMCBs
S 750 DR series technical features
S 750 DR
General Data Standards IEC/EN 60947-2
Poles 1P, 2P, 3P, 4P
Tripping characteristics Eselective, K selective
Rated current In A 16…100
Rated frequency f Hz 50 / 60
Electrical Rated operational voltage Ue V AC 230 (1-pole), 400 (2-, 3-, 4-pole)
Data Rated breaking capacity Icu kA 25
S 750 DR
acc. to IEC/
EN 60947-2 Rated service breaking capacity Ics kA 12.5
Rated insulation voltage Ui V 690
Selectivity limit current Is1 rated breaking capacity of downstream breaker (min.) –
see selectivity tables
Overvoltage category IV
Pollution degree 3
Rated impulse withstand voltage Uimp. kV 6
Impulse withstand voltage acc. to kV 8
IEC 60364-5-53 (at 2000m above sea
level)
Impulse withstand test voltage kV 9.8
(1.2/50µs)
Isolation function acc. to IEC 60364-5-53 yes
Dielectric test voltage (50/60 Hz, 1 min.) kV 2 (50 / 60 Hz, 1 min.)
Mechanical Contact position indication via toggle (I-ON / O-OFF),
Data via trip indicator (red-ON / green-OFF)
IP protection degree acc. to IEC/EN IP40 (when protected by cabinet cover)
60529
Shock resistance acc. to IEC / EN 60068- 25 g, min. 3 shocks, duration 13 ms
2-27
Vibration resistance acc. to IEC/EN 2 g, 20 cycles 5…150…5 Hz
60068-2-6
Environmental conditions (damp heat °C/ 28 cycles: 55 / 90…96 – 25 / 95…100
cyclic) acc. to IEC/EN 60068-2-30 RH
Ambient temperature °C -25 … +55
Storage temperature °C -40 … +70
Installation Wire connection (Top) frame terminal to connect solid and rigid stranded
conductors incl. flexible conductors 2.5…50 mm²
Wire connection (Bottom) frame terminal to connect solid and rigid stranded
conductors incl. flexible conductors 2.5…50 mm²
Max. torque Nm 2.5 … 3
Recommended Screwdriver slotted: 1 x 5.5, Pozidrive: PZ 2
Mounting DIN rail 35 mm acc. to EN 60715
Locking integrated blocking device, additional locking by 3 mm
padlock, 1mm seal wire or cabel binder
Mounting position any
Supply any
Dimensions Pole dimensions (H x D x W) mm see drawings
and weight Pole weight g see order tables
Accessories 3 mm padlock
auxiliary contact S750DR-aux
1/129
1
—
SMCBs
S 750 DR series - selective main circuit-breakers, Eselective characteristic
S 750 series DR
Selective main circuit-breakers of the S 750 DR series are SMCBs based on DIN VDE
0641-21 with voltage-independent operating principle. This means that they do not rely on a
control circuit to make or break contact (SHU) and are therefore particularly suitable for use
in energy distributionsystems with maximum availability requirements. They offer total
selectivity to downstream MCBs and outstanding selectivity to upstream protective devices
due to unique current limiting selectivity.
Due to the lack of international product standards for SMCB, S750DR products as given in this catalogue are certified acc.
to IEC/EN 60947-2. If requested, S750 (for 40mm busbar systems) and S750DR (for DIN rail mounting) are also available with
a certification based on a German SMCB standard. Please contact your ABB office for further information.
1/130 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
SMCBs
S 750 DR series - selective main circuit-breakers, Kselective characteristic
S 754 DR
1/131
1
—
SMCBs
S 700 series technical features
S 700
General Data Standards E DIN VDE 0645:2003-09,
partly acc. to IEC EN 60947-2
Poles 1P, 2P, 3P, 4P
Tripping characteristics Eselective, K selective
thermal tripping 1.05 … 1.2 x In
short-time delayed tripping E: 5 … 6.25 x In
K: 10 … 14 x In (≤ 50 A), 8 …12 x In (≥ 63 A)
minimum tripping delay ms 10
Rated insulation voltage Ui acc.to IEC/EN V AC 690
60664-1
S 700 Rated current In A E: 10, 80, 100: K: 80, 100
Rated frequency f Hz 50 / 60
Electrical Rated operational voltage Un V AC 1P: 230 / 400; 2…4P: 400
Data Rated breaking capacity Icn kA 25
Selectivity limit current Is1 Rated breaking capactiy of the downstream MCB
(see selectivity tables)
Overvoltage category IV
Pollution degree 3
Rated impulse withstand voltage Uimp. kV 6
Impulse withstand voltage acc. to IEC 60364- kV 8
5-53, clause 536.2 (at 2000m over sea level)
Impulse withstand test voltage (1.2/50µs) at
sea level
new condition kV 12.3
after use kV 9.8
Isolation function acc. to IEC 60364-5-53 yes
Dielectric test voltage (50/60 Hz, 1 min.) kV 2
Mechanical Contact position indication Toggle (I ON / 0 OFF); Real CPI (red ON / green OFF)
Data IP protection degree acc. to IEC/EN 60529 IP40 (in enclosure with cover, cut-out dimension
46 mm)
Mechanical switching cycles
without load ops. 1000
with rated current ops. 1000
Shock resistance acc. to IEC/EN 60068-2-27 25 g - 3 shocks - 13 ms
Vibration resistance acc. to IEC/EN 60068-2-6 2 g, 20 cycles 5…150…5Hz
Environmental conditions (damp heat cyclic) °C/ 28 cycles: 55°C/90…96% - 25°C/95…100%
acc. to IEC/EN 60068-2-30 RH
Ambient temperature °C -25 … +55
Storage temperature °C -40 … +70
Installation Terminal type Saddle terminal
Terminal size top / bottom mm 2 Capable to connect solid and rigid stranded
conductors incl. flexible conductors 2.5…50 / 70
Terminal screws tighning torque Nm 3…3.5
Max. torque for surface mounting Nm 2.5 … 3 (only fl at-headed screws, no circlips)
Recommended screwdriver Slot: 1 x 5.5, cross slot: PZ 2
Mounting Surface mounting with 2 screws, DIN rail mounting
(35 mm DIN rail acc. to EN 60715, 40 mm busbar
systems 4/5-pole, 5/10 mm x 12 mm)
Mounting position any
Supply side/load side any
Dimensions Size acc. to DIN 43880 5 (mounting on DIN-Rail); 6 (mounting on busbar)
and weight Width 2 modules / pole
Pole dimensions (H x D x W) see drawings
Pole weight see order tables
Accessories Optional: version with factory assembled auxiliary
switch (2 change-over contacts)
Terminal covers
Handle covers
Busbar adapters
DIN rail adapters
Locking devices
1/132 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High Performance MCB S800
Incomparable performances
Interchangeable
terminal, failsafe
cage or ring lug
Clear identification of terminal
the reason of cut-off
thanks to TRIP position
of the toggle
Quick identification of
technical characteristics
thanks to laser-printing
Easy product name, of all data
easy identification,
easy life.
Clear identification of
the moving contact
position thanks to
toggle identification ON,
OFF and TRIP position
1/133
1
Housing materials Shock and vibration resistance Play it safe: display the operational
In the S800 range of MCBs for traction, Additionally to the high quality state
specific materials are used that are standards and the fl ammability The mechanical drive of the S800 high
classified with an hazard level R26/HL3 requirements, rail applications have performance MCB is equipped with a
according to EN 45545-2. Plastic specific demands that have to be to trip-free release. The trip position
materials are also classified I2-F3 fulfi lled like resistance to shocks and display thereby always reliably displays
according the NF F 16-101/102 vibrations. The resistance to vibrations the exact position of the moving
(“Railway Rolling Stock Fire Behavior- and shocks of S800 has been positively contact. The trip position provides
Choice of Materials„ and “Railway tested according to: IEC 61373 – 2010 – additional trip detection allowing to
Rolling Stock Fire Behavior- Choice of 05 Edition 2.0 Rolling stock equipment easily identify the reason for the cut-
Materials, Application to Electrical – Shock and vibration tests off. The switch lever moves to the
Equipment„) thus responding to considering Category 1, Class A and middle position in case of thermal or
exigency 3. Class B. magnetic tripping.
Cage and ring terminals Reliable: the disconnector properties Wide range of accessories
The S800 standard equipment with In OFF position (0 position), the S800 S800 MCB range is completed with a
interchangeable terminal adapter for high performance MCB guarantees wide range of accessories that enlarge
wires, cables and rigid conductors safe electrical isolation of the circuit the functions of the MCB not only as a
guarantees a high level of flexibility compliant to IEC 60947-2. protection devices, but even for con-
and comfort. Fast and safe connection trol and monitor remotely the installa-
of the conductors is ensured by the tion. The range of accessories include
“onboard terminal shutter” integrated auxiliary contacts, aux/signal contacts,
into the body of the terminal, thereby remote switching unit, short circuit
preventing incorrect underclamping of limiter, shunt operation releases, un-
the connections. dervoltage releases and busbars.
1/134 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S800S series technical features
1
—
MCBs
S800S series technical features
—
MCBs
S800N series technical features
S800N
General Data
Tripping characteristics B, C, D
Standards IEC/EN 60947-2, EN 60898-1
Poles 1…4
Rated current Ie A 6 … 125
Rated frequency f Hz 50/60
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V AC 690
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category IV
Pollution degree 3
Suitability for isolation yes
Data acc. to IEC/EN 60898-1
Rated operational voltage Ue V AC 230/400
Min. operating voltage V AC 12
Rated short-circuit capacity Icn kA AC 230/400 V (10 … 80 A) = 20 kA
Reference temperature for tripping characteristics °C 30°C (Char. B, C, D)
Electrical and Mechanical Endurance ops 10...32 A: 10000 electrical / 10000 mechanical
40...80 A: 6000 electrical / 10000 mechanical
Service short-circuit capacity Ics kA 230/400 V (10 … 80 A) = 10 kA
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue AC 400/690
V DC 125 (1-pole)
DC 250 (2-pole)
DC 375 (3-pole)
DC 500 (4-pole)
Min. operating voltage V AC 12
Rated ultimate short-circuit capacity Icu kA AC 240/415 V = 36 kA
AC 254/440 V = 20 kA
AC 289/500 V = 10 kA
AC 400/690 V = 4.5 kA
DC 125 V (1-pole) = 20 kA
DC 250 V (2-pole) = 20 kA
DC 375 V (3-pole) = 20 kA
DC 500 V (4-pole) = 20 kA
Rated service short-circuit capacity Ics kA AC 240/415 V = 30 kA
AC 254/440 V (up to 63 A) = 15 kA
AC 254/440 V (80 … 125 A) = 10 kA
AC 289/500 V (up to 80 A) = 8 kA
AC 289/500 V (100 ... 125) = 5 kA
AC 400/690 V = 3 kA
DC 125 V (1-pole) = 20 kA
DC 250 V (2-pole) = 20 kA
DC 375 V (3-pole) = 20 kA
DC 500 V (4-pole) = 20 kA
Reference temperature for tripping characteristics °C 30 °C
1
—
MCBs
S800N series technical features
S800N
Installation
Terminal Failsafe cage or ringlug terminal
Connections (top/bottom) – Cu only mm2 1 … 50 stranded
1 … 70 flexible
Tightening torque Nm 3.5
in-Ibs. 31
Screwdriver POZI 2
Mounting EN 60715
Mounting position any
Supply any
Dimensions and weight
Pole dimensions (H x L x W) mm 82.5 x 95 x 26.5
Pole weight g ca. 240
1/138 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S800C series technical features
S800C
General Data
Tripping characteristics B, C, D, K
Standards IEC/EN 60947-2,EN 60898-1, UL 1077
Poles 1…4
Rated current I e A 10 … 125
Rated frequency f Hz 50/60
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V AC 500
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category IV
Pollution degree 3
Suitability for isolation yes
Data acc. to IEC/EN 60898-1
Rated operational voltage Ue V AC 230/400
Min. operating voltage V AC 12
Rated short-circuit capacity I cn kA 15 kA
Reference temperature for tripping characteristics °C 30°C (Char. B, C, D)
Electrical and Mechanical Endurance ops 10 … 32 A: 10 000 electrical/10 000 mechanical
40 … 100 A: 6000 electrical/10 000 mechanical
125 A: 4000 electrical/8 000 mechanical
Service short-circuit capacity I cs kA Char. B, C, D: 230/400 V = 7.5 kA
1
—
MCBs
S800C series technical features
S800C
Installation
Terminal Failsafe cage or ringlug terminal
Connections (top/bottom) – Cu only mm2 1 … 50 stranded
1 … 70 flexible
AWG 10 - 30 A: 14 AWG – 2 AWG
40 - 100 A: 14 AWG – 2 AWG
Tightening torque Nm 3.5
in-Ibs. 31
Screwdriver POZI 2
Mounting EN 60715
Mounting position any
Supply any
Dimensions and weight
Pole dimensions (H x L x W) mm 82.5 x 95 x 26.5
Pole weight g ca. 240
1/140 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
MCBs
S800B series technical features
S800B
General Data
Tripping characteristics B, C, D, K
Standards IEC/EN 60947-2,EN 60898-1
Poles 1…4
Rated current I e A 32 … 125
Rated frequency f Hz 50/60
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V AC 500
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 6
Overvoltage category III
Pollution degree 3
Suitability for isolation yes
Data acc. to IEC/EN 60898-1
Rated operational voltage Ue V AC 230/400
Min. operating voltage V AC 12
Rated short-circuit capacity I cn kA AC 230/400 = 10 kA
Reference temperature for tripping characteristics °C B, C, D: 30°C
Electrical and Mechanical Endurance ops. 4000
Service short-circuit capacity I cs kA AC 230/400 V = 7.5 kA
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue V AC 230/400
Min. operating voltage V AC 12
Rated ultimate short-circuit capacity I cu kA AC 230/400 V = 16 kA
DC 75 V (1-pole) = 10 kA
DC 150 V (2-pole) = 10 kA
DC 225 V (3-pole = 10 kA
DC 300 V (4-pole) = 10 kA
Rated service short-circuit capacity I cs kA 10 kA
1
—
MCBs
S800HV series technical features
S800HV
General Data
Tripping characteristics C, K
Standards IEC/EN 60947-2, UL 1077
Poles 1…3
Rated frequency f Hz 50/60
Overvoltage category III
Pollution degree 2
Suitability for isolation yes
Data acc. to IEC/EN 60947-2
—
High performance MCBs
S800S series with cage terminal, B characteristic
S800S-B characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for people and big length cables in TN and
IT systems; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs
wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2, UL 1077, supplementary protector
Icn=25kA (10 ... 80A)
Icu=50 kA
1
—
High performance MCBs
S800S series with cage terminal, B characteristic
—
High performance MCBs
S800S series with ring terminal connection, B characteristic
S800S-B characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for people and big length cables in TN and IT
systems; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired
downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2, UL 1077, supplementary protector
Icn=25kA (10 ... 80A)
Icu=50 kA
1
—
High performance MCBs
S800S series with ring terminal connection, B characteristic
—
High performance MCBs
S800S series with cage terminal, C characteristic
S800S-C characteristic
Function: protection and control of the circuits against overloads and short-circuits when a
high breaking capacity is required; protection for resistive and inductive loads with low
inrush current; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs
wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2, UL 1077, supplementary protector
Icn=25kA (10 ... 80A)
Icu=50 kA
1
—
High performance MCBs
S800S series with cage terminal, C characteristic
—
High performance MCBs
S800S series with ring terminal connection, C characteristic
S800S-C characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for resistive and inductive loads with low
inrush current; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs
wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, IEC/EN 60898
Icn=25kA (10 ... 80A)
Icu=50 kA
1
—
High performance MCBs
S800S series with ring terminal connection, C characteristic
—
High performance MCBs
S800S series with cage terminal, D characteristic
S800S-D characteristic
Function: protection and control of the circuits against overloads and short-circuits when a
high breaking capacity is required; protection for circuits which supply loads with high
inrush current at the circuit closing (motors, LV / LV transformers, breakdown lamps); very
useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2, UL 1077, supplementary protector
Icn=25kA (10 ... 80A)
Icu=50 kA
1
—
High performance MCBs
S800S series with cage terminal, D characteristic
—
High performance MCBs
S800S series with ring terminal connection, D characteristic
S800S-D characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for circuits which supply loads with high
inrush current at the circuit closing (motors, LV / LV transformers, breakdown lamps); very
useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, IEC/EN 60898
Icn=25kA (10 ... 80A)
Icu=50 kA
1
—
High performance MCBs
S800S series with ring terminal connection, D characteristic
—
High performance MCBs
S800S series with cage terminal, K characteristic
S800S-K characteristic
Function: protection and control of the circuits like motors, transformer and auxiliary
circuits, against overloads and short-circuits when a high breaking capacity is required; very
useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Advantages: no nuisance tripping in the case of functional peak currents up to 10xIn,
depending on the series; through its highly sensitive thermostatic bimetal trip, the K-type
characteristic offers protection to damageable elements in the overcurrent range; it also
provides the best protection to cables and lines.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, UL 1077, supplementary protector
Icu=50 kA
1
—
High performance MCBs
S800S series with cage terminal, K characteristic
—
High performance MCBs
S800S series with ring terminal connection, K characteristic
S800S-K characteristic
Function: protection and control of the circuits like motors, transformer and auxiliary
circuits, against overloads and short-circuits when a high breaking capacity is required; very
useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Advantages: no nuisance tripping in the case of functional peak currents up to 10xIn,
depending on the series; through its highly sensitive thermostatic bimetal trip, the K-type
characteristic offers protection to damageable elements in the overcurrent range; it also
provides the best protection to cables and lines.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
Icu=50 kA
1
—
High performance MCBs
S800S series with ring terminal connection, K characteristic
—
High performance MCBs
S800S series KM characteristic
1
—
High performance MCBs
S800S series DC range with cage terminal, UC-B characteristic
S800S-UCB characteristic
Function: protection and control of the circuits against overloads and short-circuits when a
high breaking capacity is required; protection for people and big length cables in TN and IT
systems; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired
downstream; version dedicated to application in direct current circuits.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
Icu=50 kA
—
High performance MCBs
S800S series DC range with cage terminal, UC-B characteristic
*For DC applications
1/161
1
—
High performance MCBs
S800S series DC range with ring terminal connection, UC-B characteristic
S800S-UCB characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for people and big length cables in TN and IT
systems; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired
downstream; version dedicated to application in direct current circuits.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
Icu=50 kA
—
High performance MCBs
S800S series DC range with ring terminal connection, UC-B characteristic
1
—
High performance MCBs
S800S series DC range with cage terminal, UC-K characteristic
S800S-UCK characteristic
Function: protection and control of the circuits like motors, transformer and auxiliary
circuits, against overloads and short-circuits when a high breaking capacity is required; very
useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream;
version dedicated to application in direct current circuits.
Advantages: no nuisance tripping in the case of functional peak currents up to 10xIn,
depending on the series; through its highly sensitive thermostatic bimetal trip, the K-type
characteristic offers protection to damageable elements in the overcurrent range; it also
provides the best protection to cables and lines.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
Icu=50 kA
*For DC applications
1/164 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High performance MCBs
S800S series DC range with cage terminal, UC-K characteristic
*For DC applications
1/165
1
—
High performance MCBs
S800S series DC range with ring terminal connection, UC-K characteristic
S800S-UCK characteristic
Function: protection and control of the circuits like motors, transformer and auxiliary
circuits, against overloads and short-circuits when a high breaking capacity is required;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired
downstream; version dedicated to application in direct current circuits.
Advantages: no nuisance tripping in the case of functional peak currents up to 10xIn,
depending on the series; through its highly sensitive thermostatic bimetal trip, the K-type
characteristic offers protection to damageable elements in the overcurrent range; it also
provides the best protection to cables and lines.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
Icu=50 kA
—
High performance MCBs
S800S series DC range with ring terminal connection, UC-K characteristic
1
—
High performance MCBs
S800N series with cage terminal, B characteristic
S800N-B characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for people and big length cables in TN and IT
systems; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired
downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2
Icn=20 kA (10 ... 80 A)
Icu=36 kA
—
High performance MCBs
S800N series with cage terminal, B characteristic
1
—
High performance MCBs
S800N series with cage terminal, C characteristic
S800N-C characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for resistive and inductive loads with low
inrush current; very useful when selectivity is needed vs an MCCB or back-up vs other MCBs
wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2
Icn=20 kA (10 ... 80 A)
Icu=36 kA
—
High performance MCBs
S800N series with cage terminal, C characteristic
1
—
High performance MCBs
S800N series with cage terminal, D characteristic
S800N-D characteristic
Function: protection and control of the circuits against overloads and short-circuits when
a high breaking capacity is required; protection for circuits which supply loads with high
inrush current at the circuit closing (motors, LV / LV transformers, breakdown lamps); very
useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2
Icn=20 kA (10 ... 80 A)
Icu=36 kA
—
High performance MCBs
S800N series with cage terminal, D characteristic
1
—
High performance MCBs
S800C series with cage terminal, B characteristic
S800C-B characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, IEC/EN 60898, UL 1077, supplementary protector
Icn=15 kA
Icu=25 kA
—
High performance MCBs
S800C series with cage terminal, C characteristic
S800C-C characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, IEC/EN 60898, UL 1077, supplementary protector
Icn=15 kA
Icu=25 kA
1
—
High performance MCBs
S800C series with cage terminal, D characteristic
S800C-D characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, IEC/EN 60898, UL 1077, supplementary protector
Icn=15kA
Icu=25 kA
—
High performance MCBs
S800C series with cage terminal, K characteristic
S800C-K characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, UL 1077, supplementary protector
Icu=25 kA
1
—
High performance MCBs
S800B series with cage terminal, B characteristic
S800B-B characteristic
Function: protection and control of the circuits against overloads and short-circuits. With its
lower breaking capacity it is designed to meet the needs of the sub-distributions.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, EN 60898
Icn=10kA
Icu=16 kA
—
High performance MCBs
S800B series with cage terminal, C characteristic
S800B-C characteristic
Function: protection and control of the circuits against overloads and short-circuits. With its
lower breaking capacity it is designed to meet the needs of the sub-distributions.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, EN 60898
Icn=10kA
Icu=16 kA
1
—
High performance MCBs
S800B series cage terminal, D characteristic
S800B-D characteristic
Function: protection and control of the circuits against overloads and short-circuits. With
its lower breaking capacity it is designed to meet the needs of the sub-distributions.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, EN 60898
Icn=10kA
Icu=16 kA
—
High performance MCBs
S800B series with cage terminal, K characteristic
S800B-K characteristic
Function: protection and control of the circuits against overloads and short-circuits. With its
lower breaking capacity it is designed to meet the needs of the sub-distributions.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2, EN 60898
Icn=10kA
Icu=16 kA
1
—
High performance MCBs
S800HV series for application up to 1000V AC
S800HV-K characteristics
Function: protection and control of the circuits against overloads and short-circuits.
With its Function: S800HV is designed for voltages up to 580/1000 V AC. Due to the high
rated operational voltage, the field of application is wide – from underground mining to
distributions on high altitudes.
Applications: Industrial
Standard: IEC/EN 60947-2, UL 1077, supplementary protector
Icu 1.5 kA (0.5...5 A) 4 kA (6 … 63 A); 3 kA (80 … 125 A)
—
High performance MCBs
S800HV series for application up to 1000V AC
S800HV-C characteristics
Function: protection and control of the circuits against overloads and short-circuits. With its
Function: S800HV is designed for voltages up to 580/1000 V AC. Due to the high rated
operational voltage, the field of application is wide – from underground mining to
distributions on high altitudes.
Applications: industrial
Standard: IEC/EN 60947-2, UL 1077, supplementary protector
Icu = 4 kA
S803HV
1/183
1
—
High performance MCBs
S800UP series technical features
S800UP
General Data
Tripping characteristics K, Z
Standards UL489
Poles 1…3
Rated current Ie A 20, 30
Rated frequency f Hz 50/60
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V AC 690
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category IV
Pollution degree 3
Suitability for isolation yes
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue V AC 240/415
Min. operating voltage V AC 12
Rated ultimate short-circuit capacity Icu kA AC 240 V (1-pole) = 30 kA
AC 415 V (multipole) = 50 kA
Rated service short-circuit capacity Ics kA AC 240 V (1-pole) = 25 kA
AC 415 V (multipole) = 40 kA
Reference temperature for tripping characteristics °C 25 °C
Electrical and Mechanical Endurance ops. Up to 30 A: 10000 electrical / 10000 mechanical
Data acc. to UL / CSA
Rated voltage V AC 480Y/277
Rated interrupting capacity acc. to UL 1077 kA
Short-circuit current rating acc. to UL 489 kA AC 277 V (1-pole) = 25 kA
AC 480 V (multipole) = 25 kA
Short-circuit current rating acc. to UL 489B kA
Reference temperature for tripping characteristics 25 °C
Electrical and Mechanical endurance ops. acc. to UL489
6000 electrical; 4000 mechanical
Mechanical Data
Protection degree acc. to EN 60529 IP20; IP40 (actuating end only)
Shock resistance acc. to IEC/EN 60068-2-30 IEC 61373 Cat. 1 Class B, 5 g/30 ms acc. To IEC 60068-27 Test Ea
Vibration resistance acc. to IEC/EN 60068-2-6 IEC 60068-2-6 Test Fc;
2 - 13.2 Hz/1 mm
13.2 - 100 Hz/0.7 g
with load 100 % x Ie
Environmental conditions (damp heat) °C/RH 12 + 12 cycle with 55 °C/90 - 96 %
acc. to IEC/EN 60068-2-30 and 25 °C/95 - 100 %
Environmental conditions (dry heat) °C/RH 16 hours 55 °C/2 hours 70 °C
acc. to IEC/EN 60068-2-2 Test B with damp heat 55 %
Ambient temperature °C -25 … +60
Storage temperature °C -40 … +70
Installation
Terminal Failsafe cage or ringlug terminal
Connections (top/bottom) – Cu only mm2 1 … 50 stranded
1 … 70 flexible
AWG Up to 30 A: 14 - 2 AWG
Tightening torque Nm 3.5
in-Ibs. 31
Screwdriver POZI 2
Mounting any
Mounting position any
Supply any
Dimensions and weight
Pole dimensions (H x L x W) mm 142 x 26.5 x 82.5
Pole weight g 270
1/184 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High performance MCBs
S800U series technical features
S800U
General Data
Tripping characteristics K, Z
Standards UL489
Poles 1…4
Rated current Ie A 10...100
Rated frequency f Hz 50/60
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V AC 690
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category IV
Pollution degree 3
Suitability for isolation yes
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue V AC 240/415
Min. operating voltage V AC 12
Rated ultimate short-circuit capacity Icu kA AC 240 V (1-pole) = 30 kA
AC 415 V (multipole) = 50 kA
Rated service short-circuit capacity Ics kA AC 240 V (1-pole) = 25 kA
AC 415 V (multipole) = 40 kA
Reference temperature for tripping characteristics °C 25 °C
Electrical and Mechanical Endurance ops. 10...32 A: 10000 electrical / 10000 mechanical
40...100 A: 6000 electrical / 10000 mechanical
Data acc. to UL / CSA
Rated voltage V AC 240
Rated interrupting capacity acc. to UL 1077 kA
Short-circuit current rating acc. to UL 489 kA AC 240 V (1-pole) = 30 kA
AC 240 V (multipole) = 50 kA
Short-circuit current rating acc. to UL 489B kA
Reference temperature for tripping characteristics 25 °C
Electrical and Mechanical endurance ops. acc. to UL489
6000 electrical; 4000 mechanical
Mechanical Data
Protection degree acc. to EN 60529 IP20; IP40 (actuating end only)
Shock resistance acc. to IEC/EN 60068-2-30 IEC 61373 Cat. 1 Class B, 5 g/30 ms acc. To IEC 60068-27 Test Ea
Vibration resistance acc. to IEC/EN 60068-2-6 IEC 60068-2-6 Test Fc;
2 - 13.2 Hz/1 mm
13.2 - 100 Hz/0.7 g
with load 100 % x Ie
Environmental conditions (damp heat) °C/RH 12 + 12 cycle with 55 °C/90 - 96 %
acc. to IEC/EN 60068-2-30 and 25 °C/95 - 100 %
Environmental conditions (dry heat) °C/RH 16 hours 55 °C/2 hours 70 °C
acc. to IEC/EN 60068-2-2 Test B with damp heat 55 %
Ambient temperature °C -25 … +60
Storage temperature °C -40 … +70
Installation
Terminal Failsafe cage or ringlug terminal
Connections (top/bottom) – Cu only mm2 1 … 50 stranded
1 … 70 flexible
AWG 10 - 30 A: 14 - 2 AWG
40 - 100 A: 1 - 8 AWG
Tightening torque Nm 3.5
in-Ibs. 31
Screwdriver POZI 2
Mounting any
Mounting position any
Supply any
Dimensions and weight
Pole dimensions (H x L x W) mm 95 x 26.5 x 82.5
Pole weight g 240
1/185
1
—
High performance MCBs
S804U-UCZ series technical features
S804U-UCZ
General Data
Tripping characteristics UCZ
Standards UL489
Poles 4
Rated current Ie A 10 - 80
Rated frequency f Hz -
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V DC 1500
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category IV
Pollution degree 3
Suitability for isolation yes
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue V -
Min. operating voltage V -
Rated ultimate short-circuit capacity Icu kA -
Rated service short-circuit capacity Ics kA -
Reference temperature for tripping characteristics °C -
Electrical and Mechanical Endurance ops. -
Data acc. to UL / CSA
Rated voltage V DC 600
Rated interrupting capacity acc. to UL 1077 kA -
Short-circuit current rating acc. to UL 489 kA 10
Short-circuit current rating acc. to UL 489B kA -
Reference temperature for tripping characteristics 25 °C
Electrical and Mechanical endurance ops. acc. to UL489
6000 electrical; 4000 mechanical
Mechanical Data
Protection degree acc. to EN 60529 IP20; IP40 (actuating end only)
Shock resistance acc. to IEC/EN 60068-2-30 -
Vibration resistance acc. to IEC/EN 60068-2-6 -
—
High performance MCBs
S804U-PVS series technical features
S804U-PVS
General Data
Tripping characteristics PVS
Standards UL489B (Photovoltaic)
Poles 4
Rated current Ie A 5
Rated frequency f Hz -
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V DC 1500
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category III
Pollution degree 2
Suitability for isolation yes
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue V -
Min. operating voltage V -
Rated ultimate short-circuit capacity Icu kA -
Rated service short-circuit capacity Ics kA -
Reference temperature for tripping characteristics °C -
Electrical and Mechanical Endurance ops. -
Data acc. to UL / CSA
Rated voltage V DC 1000
Rated interrupting capacity acc. to UL 1077 kA -
Short-circuit current rating acc. to UL 489 kA -
Short-circuit current rating acc. to UL 489B kA 3 kA
Reference temperature for tripping characteristics 50 °C
Electrical and Mechanical endurance ops. acc. to UL489
1000 electrical; 1000 mechanical
Mechanical Data
Protection degree acc. to EN 60529 IP20; IP40 (actuating end only)
Shock resistance acc. to IEC/EN 60068-2-30 -
Vibration resistance acc. to IEC/EN 60068-2-6 -
Environmental conditions (damp heat) °C/RH -
acc. to IEC/EN 60068-2-30
Environmental conditions (dry heat) °C/RH -
acc. to IEC/EN 60068-2-2 Test B
Ambient temperature °C -25 … +60
Storage temperature °C -40 … +70
Installation
Terminal Failsafe cage terminal
Connections (top/bottom) – Cu only mm2 1 … 50 stranded
1 … 70 flexible
AWG 14 AWG - 2 AWG
Single conductor per terminal, 75C wire
Flexible Cross-section of conductors mm2 -
(top/bottom) AWG 14 AWG - 2 AWG
Single conductor per terminal - copper only, 75C wire
Tightening torque Nm 3.5
in-Ibs. 31
Screwdriver POZI 2
Mounting any
Mounting position any
Supply any
Dimensions and weight
Pole dimensions (H x L x W) mm 142 x 26.5 x 82.5
Pole weight g 240
1/187
1
—
High performance MCBs
S800U series technical features
—
High performance MCBs
S800UP series with cage terminal, K characteristic
S800UP-K characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: UL489, CSA 22.2 NO.5-02
Icu = 25 kA
1
—
High performance MCBs
S800UP series with cage terminal, Z characteristic
S800UP-Z characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: UL489, CSA 22.2 NO.5-02
Icu = 25 kA
—
High performance MCBs
S800U series with cage terminal, Z characteristic
S800U-Z characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: UL489, CSA 22.2 NO.5-02, IEC/EN 60947-2
Icu=30 kA (1 pole), 50 kA (2...4 poles)
1
—
High performance MCBs
S800U series with cage terminal, K characteristic
S800U-K characteristic
Function: protection and control of the circuits against overloads and short-circuits when a high
breaking capacity is required; protection for people and big length cables in TN and IT systems;
very useful when selectivity is needed vs an MCCB or back-up vs other MCBs wired downstream.
Applications: commercial and industrial.
Standard: UL489, CSA 22.2 NO.5-02, IEC/EN 60947-2
Icu=30 kA (1-pole), 50 kA (2...4-pole)
—
High performance MCBs
S800U series UCZ characteristic
1
—
High performance MCBs
S800U series PVS characteristic
Number Icu Rated current GTIN EAN Order details Weight Pack.
of poles [kA] [A] 7612271 Type Code Order code [kg] unit
4 3 5 419929 S804U-PVS5 2CCP824017R1159 0.98 1
1/194 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High performance MCBs
S800PV-SP series technical features
S800PV-SP
General Data
Tripping characteristics SP
Standards IEC / EN 60947-2 and Annex P
Poles 2 ... 4
Rated frequency Ie A 5 ... 125
Rated frequency f Hz -
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V DC 1500
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8
Overvoltage category III*
Pollution degree 2
Suitability for isolation yes
Data acc. to IEC/EN 60947-2
Rated operational voltage Ue V 2-pole
DC 800 V: 5 … 125 A
3-pole
DC 1200 V: 5 … 125 A
4-pole
DC 1500 V: 5 … 125 A
Min. operating voltage V -
Rated ultimate short-circuit capacity Icu kA 5 … 16 A acc. IEC 60947-2 Annex P.
Icu = 5 kA
20 … 125 A, acc. IEC 60947-2, Icu = 5 kA
20 … 125 A, acc. IEC 60947-2 Annex P.
Icu = 3 kA
Rated service short-circuit capacity Ics kA Icu = Ics
Reference temperature for tripping characteristics °C 40 °C
Electrical and Mechanical Endurance ops. acc. to Annex P:
5 … 16 A: 300 electrical/9700 mechanical
acc. to IEC 60947-2 (general part):
20 … 100 A: 1500 electrical/8500 mechanical
125 A: 1000 electrical/9000 mechanical
Mechanical Data
Housing Material group I, RAL 7035
Toggle black, lockable
Classification acc. To NF F 126-101, NF F 16-102 -
Protection degree acc. to EN 60529 IP20; IP40 (actuating end only)
Shock resistance acc. to IEC/EN 60068-2-30 IEC 61373 Cat. 1 Class B, 5 g / 30 ms acc. To IEC 60068-27 Test Ea
Vibration resistance acc. to IEC/EN 60068-2-6 IEC 60068-2-6 Test Fc;
2 - 13.2 Hz/1 mm
13.2 - 100 Hz/0.7 g
with load 100 % x Ie
Environmental conditions (damp heat) °C/RH 12 + 12 cycle with 55 °C/90 - 96 % and 25 °C/95 - 100 %
acc. to IEC/EN 60068-2-30
Environmental conditions (dry heat) °C/RH 16 hours 55 °C/2 hours 70 °C with damp heat 55 %
acc. to IEC/EN 60068-2-2 Test B
Ambient temperature °C -25 … +60
Storage temperature °C -40 … +70
Installation
Terminal Failsafe cage or ringlug terminal
Connections (top/bottom) - Cu only mm2 1 … 50 stranded
1 … 70 flexible
Tightening torque Nm 3.5
in-Ibs. 31
Screwdriver POZI 2
Mounting any
Mounting position any
Supply any
Dimensions and weight
Pole dimensions (H x L x W) mm 95 x 26.5 x 82.5
Pole weight g 240
*The pollution degree of the product, as defined in standard IEC 60947-1, is related to its micro environment, to which equipment is exposed. It may be different from that of
the macro-environment. According to where the equipment is located, the pollution degree of the macro environment can be considered up to category IV if protection is
offered by means of such as an adequate enclosure or internal heating to prevent absorption or condensation of moisture.
1/195
1
—
High performance MCBs
S802PV-M-H and S800PV-SD technical features
S802PV-M-H S800PV-SD
General Data
Tripping characteristics none none
Standards IEC / EN 60947-3 IEC / EN 60947-3 and Annex D
Poles 2 (polarized) 2 ... 4
Rated current Ie A 32, 63, 100 32, 63, 125
Rated insulation voltage Ui acc. to IEC/EN 60664-1 V DC 1500 DC 1500
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8 8
Overvoltage category III* III*
Pollution degree 2 2
Suitability for isolation yes yes
Data acc. to IEC/EN 60947-3
Rated operational voltage Ue V DC 1000 V: 2-pole DC 800V: 2-pole
DC 1200V: 3-Pole
DC 1500 V: 4-pole
Min. operating voltage V - -
Rated short-term withstand current Icw kA 1.5 1.5
Rated short-circuit making capacity Icm kA 0.5 0.5
Utilisation category DC-21 A DC-21 A, DC-PV2
Electrical and Mechanical Endurance ops. 1500 electrical / 10000 mechanical 32, 63 A: 1500 electrical /
10000 mechanical
125 A: 1000 electrical /
8000 mechanical
Mechanical Data
Housing Material group I, RAL 7035 Material group I, RAL 7035
Toggle black, lockable black, lockable
Classification acc. To NF F 126-101, NF F 16-102 - -
Protection degree acc. to EN 60529 IP20; IP40 (actuating end only) IP20; IP40 (actuating end only)
Shock resistance acc. to IEC/EN 60068-2-30 IEC 61373 Cat. 1 Class B, 5 g / IEC 61373 Cat. 1 Class B, 5 g /
30 ms acc. To IEC 60068-27 Test Ea 30 ms acc. To IEC 60068-27 Test Ea
Vibration resistance acc. to IEC/EN 60068-2-6 IEC 60068-2-6 Test Fc; IEC 60068-2-6 Test Fc;
2 - 13.2 Hz/1 mm 2 - 13.2 Hz/1 mm
13.2 - 100 Hz/0.7 g 13.2 - 100 Hz/0.7 g
with load 100 % x Ie with load 100 % x Ie
Environmental conditions (damp heat) °C/RH 12 + 12 cycle with 55 °C/90 - 96 % and 12 + 12 cycle with 55 °C/90 - 96 % and
acc. to IEC/EN 60068-2-30 25 °C/95 - 100 % 25 °C/95 - 100 %
Environmental conditions (dry heat) °C/RH 16 hours 55 °C/2 hours 70 °C with damp 16 hours 55 °C/2 hours 70 °C with
acc. to IEC/EN 60068-2-2 Test B heat 55 % damp heat 55 %
Ambient temperature °C -25 … +60 -25 … +60
Storage temperature °C -40 … +70 -40 … +70
Installation
Terminal Failsafe cage or ringlug terminal Failsafe cage or ringlug terminal
Connections (top/bottom) - Cu only mm2 1 … 50 stranded 1 … 50 stranded
1 … 70 flexible 1 … 70 flexible
Tightening torque Nm 3.5 3.5
in-Ibs. 31 31
Screwdriver POZI 2 POZI 2
Mounting any any
Mounting position any any
Supply any any
(taking into account the polarization) (taking into account the polarization)
Dimensions and weight
Pole dimensions (H x L x W) mm 95 x 26.5 x 82.5 95 x 26.5 x 82.5
Pole weight g 240 240
*The pollution degree of the product, as defined in standard IEC 60947-1, is related to its micro environment, to which equipment is exposed. It may be different from that of
the macro-environment. According to where the equipment is located, the pollution degree of the macro environment can be considered up to category IV, if protection is
offered by means of such as an adequate enclosure or internal heating to prevent absorption or condensation of moisture.
1/196 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
1
—
High performance MCBs
S800PV series with cage terminal, B characteristic
S800PV-SP
Function: protection and control of photovoltaic strings against overloads, short-circuits
and reverse currents. Ideal replacement for fuses due to comfortable string failure
identification and signalisation.
Applications: Photovoltaic systems. Standard: IEC 60947-2 and Annex P
5 ... 16A acc. IEC 60947-2 Annex P., Icu 5 kA
20 ... 125A acc. IEC 60947-2, Icu 5 kA
5 ... 125A acc. IEC 60947-2 Annex P., Icu 3 kA
1
—
High performance MCBs
S800PV series with cage terminal, B characteristic
S802PV-M-H
Function: this polarized disconnector is designed to meet the requirements for photovoltaic
systems. Voltage up to 1000 V d.c. and rated current up to 100 A.
2 4 2 4
- + L+ L-
S800PV-SD
Function: switch disconnector for DC side isolation of PV systems.
Designed for PV installations of 1500 V DC.
Applications: Photovoltaic systems
Rated short-term withstand current, Icw 1,5 kA
2
Electrical installation solutions for buildings
Residual current devices
Index
Quick selection of RCDs for household
and industrial applications 2/2
RCCBs
F 200 2/6
F 200 for overseas markets 2/12
F 200 left neutral 2/14
F 200 AP-R (high immunity) 2/18
F 200 110 V 2/20
F 200 for high frequency and railways
applications2/21
F 200 F type 2/22
F 200 B type 2/34
F 200 F-ATI and F-ARI 2/38
RCD-blocks
DDA 200 2/42
DDA 200 special version 110 V and 400 V 2/48
DDA 200 AP-R 2/49
DDA 200 AE for emergency stop 2/50
DDA 200 selective 2/51
DDA 200 B APR 2/52
DDA 800 2/54
RCBOs
DS201 L 2/64
DS2012/67
DS201 T 2/73
DS201 M 2/74
DS201 M 110V 2/86
DS201 UL 2/87
DS202C2/89
DS202C M 2/92
DS202C M 110V 2/96
DS203NC L 2/102
DS203NC 2/105
DS 200 2/112
DS 200 M 2/121
DS800S, DS800N 2/126
eRCBOs
DSE2012/136
DSE201 M 2/140
—
2
6 kA
36 kA
50 kA
10 kA
2
—
System pro M compact®
Quick selection of RCDs for household and industrial applications
—
2
6 kA
INDUSTRIAL
START 10 kA
36 kA
50 kA
2
—
System pro M compact®
Quick selection of RCDs for household and industrial applications
Up to 63 A RCD: IEC/EN 61009 Ann. G All poles DDA 200 + S200 2/44 + 1/26
RCD: IEC/EN
Up to 100 A All poles DDA 800 + S800 2/56 + 1/120
60947-2 Ann. B
—
2
RCCB F 200.
The details make the difference
A range designed to ensure efficiency
and protection
Bi-directional cylindrical
terminal ensure higher
safety of connecting
operations, making them
Test pushbutton easier.
to verify the correct
functioning of the device.
2
Two terminals are available, the fore RCCBs F200 can be used in ambient The availability of two terminals offers
one for cables up to 25 mm2, the back conditions where the temperature of different connection solutions thanks
one for cables up to 10 mm2 or for the surrounding atmosphere has to the possibility to connect two
busbars. values between -25 °C (snowflake laser indipendent cables in the same device:
printed on the front of the device) and the second terminal can be used for an
+55°C. auxiliary circuit or for the supply of
devices with small section cables
without connecting them together
with the main circuit.
All the safety ensured by the High performances: The F 202 can be coupled with the
international marks: approvals’ • rated breaking capacity and autoreclosing unit F2C-ARH in order to
marking in a visible area, even if RCDs rated residual breaking capacity ensure continuity of service for the
is installed and with the panel-door laser printed on the device: whole installation of your home avo
closed. Im=IΔm= 1000 A ding lack of supply.
• coordination with a 100 A rated
current SCPD (short-circuit
protective device) = 10 000 A.
2/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCCBs
F200 technical features
Standards
UL/CSA V
Rated frequency Hz
Rated conditional short-circuit current SCPD - fuse gG 100 A kA
Inc=I∆ c
Rated residual breaking capacity I∆m=Im kA
Rated impulse withstand voltage (1.2/50) Uimp kV
Dielectric test voltage at ind. freq. for 1 min. kV
Overvoltage category
Surge current resistance (wave 8/20) A
Mechanical Toggle
features Contact position indicator (CPI)
Electrical life
Mechanical life
Protection degree housing
terminals
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 °C/RH
Ambient temperature (with daily average ≤ IEC °C
+35 °C)
Storage temperature °C
Installation Terminal type
Terminal size top/bottom for cable IEC mm2
UL/CSA AWG
Terminal size top/bottom for busbar IEC mm2
UL/CSA AWG
Tightening torque IEC Nm
UL/CSA in-lbs.
Tool
Mounting
Mounting position
Connection
Withdrawal from busbar
Dimensions Dimensions (H x D x W) 2P mm
and weight 4P mm
Weight 2P g
4P g
Combination Combinable with: auxiliary contact
with signal contact/auxiliary switch
auxiliary shunt trip
elements
undervoltage release
2
—
RCCBs
F200 technical features
F200 AC F200 A F200 A AP-R F200 A S F200 A 110V F200 A 400 Hz F200 A 16 2/3 Hz
IEC/EN 61008-1; IEC/EN 61008-2-1, UL 1053 IEC 61008-1; IEC IEC/EN 61008-1; IEC/EN 61008-1;
61008-2-1; UL 1053 IEC/EN 61008-2-1 IEC/EN 61008-2-1
AC A A A A A A
2P , 4P (for 125 A only 4P) 2P, 4P 4P 2P, 4P
16, 25, 40, 63, 80, 100, 125 25, 40, 63, 80, 100, 40, 63, 80, 100, 125 25, 40, 63, 80, 100 25, 40 63
125
0.01-0.03-0.1-0.3-0.5 0.03 0.1-0.3-0.5-1 0.03 0.03 0.03-0.3-0.5
230/400 - 240/415
480Y/277 (up to 100 A) - -
500
In ≤ 100; Right neutral: 110 (170 for 30mA) - 254 e; Left neutral: 195 (250 for 30 mA) - 110-254 170-254 110 (170 for
440 e 30 mA) - 254
In = 125 A; Right neutral: 185 (150 for 30 mA) - 440 (250 for 30 mA) e;
Left neutral: 195 (250 for 30 mA) - 440
In ≤ 100; Right neutral: 110 (170 for 30mA) - 277 e; Left neutral: 195 (250 for 30 mA) - 480 e d -
50…60 50...400 16 2/3
10 (for 125 A fuse is gG 125 A)
-40…+70
failsafe bi-directional cylinder-lift terminal at top and bottom (shock protected) (cage for In > 63 A) b
25/25 (35/35 single slot terminal for In > 63 A) 25/25 25/25
18-4 (up to 63 A) - -
10/10 (not for In = 80-100 A) 10/10 10/10
18-8 (up to 63 A) - -
2.8 (3 for In = 125 A) 2.8 2.8 2.8
25 (up to 63 A) - -
Nr. 2 Pozidriv
on DIN rail EN 60715 (35 mm) by means of fast clip device
Any
from top and bottom
it is possible without using any tools only from the bottom (not for 125 A)
85 x 69 x 35 -
85 x 69 x 70 (85 x 69.5 x 72 for 125 A) 85 x 69 x 70 85 x 69 x 70
200 -
350 (380 for In = 80 and 100 A and 460 for In = 125A) 350 350
yes (no for 125 A) yes yes
yes yes yes
yes (no for 125 A) yes yes
yes (no for 125 A) yes yes
2/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCCBs
F 200 series AC w type
F 200 AC type
Function: protection against the effects of sinusoidal alternating earth fault currents;
protection against indirect contacts and additional protection against direct contacts
(with I∆n=30 mA).
2
—
RCCBs
F 200 series AC w type
—
RCCBs
F 200 series AC w type, for overseas markets
2
—
RCCBs
F 200 series AC w type, for overseas markets
—
RCCBs
F 200 series AC w type left neutral
2
—
RCCBs
F 200 series A y type
F 200 A type
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contacts and additional protection against direct
contacts (with I∆n=30 mA).
—
RCCBs
F 200 series A y type
2
—
RCCBs
F 200 series A y type left neutral
—
RCCBs
F 200 series A y type, AP-R (high immunity)
F204
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 8012542 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 30 25 785408 F204 A-25/0.03 AP-R 2CSF204401R1250 0.375 1/3
40 785507 F204 A-40/0.03 AP-R 2CSF204401R1400 0.375 1/3
63 785606 F204 A-63/0.03 AP-R 2CSF204401R1630 0.375 1/3
80 919407 F204 A-80/0.03 AP-R 2CSF204401R1800 0.405 1/3
100 919506 F204 A-100/0.03 AP-R 2CSF204401R1900 0.405 1/3
125 967903 F204 A-125/0.03 AP-R 2CSF204401R1950 0.500 1
F204 125 A
2/19
2
—
RCCBs
F 200 series A y type, selective
F204 125 A Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 8012542 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 100 40 823308 F204 A S-40/0.1 2CSF204201R2400 0.375 1/3
63 823407 F204 A S-63/0.1 2CSF204201R2630 0.375 1/3
100 919001 F204 A S-100/0.1 2CSF204201R2900 0.405 1/3
300 40 784708 F204 A S-40/0.3 2CSF204201R3400 0.375 1/3
63 784807 F204 A S-63/0.3 2CSF204201R3630 0.375 1/3
100 919100 F204 A S-100/0.3 2CSF204201R3900 0.405 1/3
125 968207 F204 A S-125/0.3 2CSF204201R3950 0.500 1
500 40 784906 F204 A S-40/0.5 2CSF204201R4400 0.375 1/3
63 785002 F204 A S-63/0.5 2CSF204201R4630 0.375 1/3
100 919209 F204 A S-100/0.5 2CSF204201R4900 0.405 1/3
125 968405 F204 A S-125/0.5 2CSF204201R4950 0.500 1
1000 40 823506 F204 A S-40/1 2CSF204201R5400 0.375 1/3
63 823605 F204 A S-63/1 2CSF204201R5630 0.375 1/3
100 919308 F204 A S-100/1 2CSF204201R5900 0.405 1/3
2/20 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCCBs
F 200 110V series A y type
F204 110V
2
—
RCCBs
F 200 series A y type for high frequency and railways applications
Application: railways
Standard: IEC/EN 61008-1; IEC/EN 61008-2-1
Marking: according to EN 61008-1; EN 61008-2-1
—
2
Test pushbutton
to verify the correct
functioning of the device.
2
RCCBs F200 can be used in ambient conditions The availability of two terminals offers different
where the temperature of the surrounding connection solutions thanks to the possibility to
atmosphere has values between -25 °C (snowflake connect two indipendent cables in the same
laser printed on the front of the device) and +55 °C. device: the second terminal can be used for an
auxiliary circuit or for the supply of devices with
small section cables without connecting them
together with the main circuit.
—
2
Bi-directional cylindrical
terminal ensure higher
safety of connecting
operations, making them
easier.
Contact position
Information on the
indicator (CPI):
device are laser
red - closed contacts;
printed to ensure
green - open contacts.
readability over time
(including product
code).
Test pushbutton
to verify the correct
functioning of the device.
2/25
2
Any earth fault can be immediately identified The terminals available on DS201 make easier the
through the blue indicator, that signals the supply operation in parallel with busbars as they
differential tripping and which cannot be are composed by two different seats, a front seat
activated in case of manual operation on the for 25 mm2 cables and a back seat for 10 mm2
toggle. This prevents any misinterpretations of busbars.
the device and system status.
Label carrier for clear and reliable identification. All the devices of the DS201 series have been
With the practical label carrier fitted in the new tested in a wide range of temperatures:
circuit breakers you can give maximum visibility from -25 °C (as indicated by the snowflake
to the information relating to the protected marked on the front side) up to +55 °C.
loads.
2/26 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
—
2
Test pushbutton
to verify the correct RCD tripping indicator:
functioning of the device. Blue lever goes down in case
of RCD tripping
Information on the
device are laser
printed to ensure
readability over time
(including product
code). Laser-marked order code on
the front to make easier
future orders.
+ =
2
Flexibility RCD block DDA200 can be used in ambient
DDA200 is suitable for mounting with S200 conditions where the temperature of the
extensive range of MCBs, covering applications in surrounding atmosphere has values between
2P up to 63A with breaking capacity up to 25kA. -25 °C (snowflake laser printed on the front of the
device) and +55 °C.
—
RCCBs
F 200 series - F technical features
Standards
Electrical Type
features
Number of poles
Rated current In
Rated sensitivity I∆n
Rated voltage Ue
Insulation voltage Ui
Max. / Min. operating voltage of circuit test
Rated frequency
Rated breaking capacity acc. to IEC/EN 61009 ultimate Icn
Rated breaking capacity
ultimate Icu
acc. to IEC/EN 60947-2 1P+N @230 VAC
service Ics
Rated residual breaking capacity I∆m
Rated conditional short-circuit current Inc=IΔc SCPD - fuse gG 100 A
Rated impulse withstand voltage (1.2/50) Uimp
Dielectric test voltage at ind. freq. for 1 min.
Thermomagnetic release characteristic B: 3 In ≤ Im ≤ 5 In
C: 5 In ≤ Im ≤ 10 In
Surge current resistance (wave 8/20)
Mechanical Toggle
features
Flag indicators contact position indicator (green/red)
Electrical life
Mechanical life
Protection degree housing
terminal
Environmental conditions (damp heat)
acc. to IEC/EN 60068-2-30
Reference temperature for setting of thermal element
Ambient temperature (with daily average ≤ +35 °C)
Storage temperature
Installation
Terminal type
1
RCD-blocks DDA 200 with rated current 63 A are provided with two additional terminals for remote tripping.
2/29
2
—
RCCBs
F 200 series - F technical features
- 30 °C -
-25…+55 °C
-40…+70 °C
Top: failsafe bi-directional cylinder-lift terminal
(shock protected)
failsafe bi-directional cylinder-lift terminal at top and bottom (shock protected)
Bottom: failsafe cylinder-lift terminal
(shock protected)
25/25 mm2
10/10 mm2 10/- mm2
2.8 Nm
N°2 Pozidriv
on DIN rail EN 60715 (35 mm) by means of fast clip device
from top and bottom
2P: 85 x 69 x 35 mm; 4P: 85 x 69 x 70 mm 1P+N: 85 x 67 x 35 mm 2P: 93 x 69 x 69,5 mm
2P: 225 g; 4P: 375 g 1P+N: 240 g 2P: 180 g
auxiliary contact, signal contact, shunt trip, undervoltage release (see next pages)
2/30 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCCBs
F 200 series - F
RCCB F200
2
—
RCCBs
F 200 series - F
Accessories
Auxiliary contact
Signal/Auxiliary contact
Undervoltage releases
Overvoltage releases
—
RCCBs
F 200 series - F
Accessories
Auto-reclosing units
2
—
RCCBs
F 200 series - F
Accessories
Shunt trips for RCCB F200 and RCBO DS201
—
2
F 200 series - B
Details that make the difference
VDE approved
Indication of the
position of the contacts
2/35
2
—
F 200 series - B
Details that make the difference
Cutting-edge features: safety, service continuity, Compatible with all System pro M compact
compactness, integration. These are the accessories of F200 series.
characteristics of the F200 B RCCBs (residual Higher operational continuity thanks to auto-
current circuit breakers), the state-of-the-art reclosing units and motor operating devices.
technology by ABB which has been providing the Operating temperature from -25 to +60 °C with
best solutions for residential, commercial and high immunity for extremely harsh weather
industrial installations for over 120 years. conditions. F200 B can be installed either in two-
The F200 B Type is the ultimate novelty of the phase and three-phase networks.
System pro M compact offering. A lot of space saving thanks to the two poles
The most compact device in the market. Type B device in just two modules.
RCCBs can be adapted perfectly to all types of Coordination and back-up with all ABB devices.
installation requirements and application fields.
The F200 B Type can be perfectly integrated with
all devices produced by ABB in terms of
connection, selectivity data and coordination.
2/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCCBs
F 200 series - B technical features
1
Ground-Fault Sensing and Relaying Equipment” (F200 up to 100 A)
2
Prior to connection of aluminium conductors (≥ 4 mm2) ensure that their contact points are cleaned, brushed and coated with grease
3
for S700-E/K 100A, S750-E 63A, S750DR-E/K 63A and other SCPD coordination values are available.
2/37
2
—
RCCBs
F 200 series - B y type for continuous, selective continuous
type fault currents technical features
F200 B Type from 16 to 63 A
—
RCCBs
F-ATI and F-ARI
F-ATI and F-ARI Test are RCCBs equipped with automatic test features. RCCBs are supposed
to be checked every six months in order to make sure that the contacts are working properly
and the device is able to trip in case of a leakage to earth. This swift operation affects the
operational continuity of the circuits downstream and required a lot of man power. F-ATI and
F-ARI test ranges push the periodic test to another level as this is run automatically and with
no interruption at all of the service. Therefore, also the operations carried out by mainte-
nance personnel are reduced to the very minimum.
In addition to the automatic test, F-ARI Range features a reclosing unit that tries to reclose
the RCCB as it trips. The reclosing operations are based on an insulation check to make sure
that no permanent fault is present. The insulation check is done with a very low current with
no danger for human at any time. Once the insulation check is positive the reclosing unit
recloses the RCCB again. Moreover, the results coming from each and every circuit are
collected at once thanks to ARBus interface.
• Saving: maintenance costs are cut down as the device runs automatically the test monthly
in accordance with EN 61008 provisions.
• Uptime: while running the test, no disconnection of the supply occurs like in the traditional
RCCB units.
• Time saving: a full array of maximum 99 devices can be commanded and read by remote by
the means of the ARBus interface.
• Easy installation: the unit is factory fitted and it needs no coupling
• Quality: F-ATI Test range is approved by VDE while F-ARI Test is approved by IMQ CSV.
• Smart: complete monitoring over the application thanks to a fault check system and
a programmable aux contact
• Reliability: Suitable for demanding environments up to 60 °C
• High immunity: RCCBs Type A APR offer the adequate solution according to the type
of loads to be protected , the level of safety and the continuity of service. (inserire forme
d’onda ammesse per APR)
2/39
2
—
RCCBs
F-ATI and F-ARI technical features
ARBus
Electrical features Rated voltage Ue 230 V a.c. -15% ÷ 10%
Rated frequency 50 Hz
Insulation voltage Ui 500 V d.c.
Rated conditional short-circuit Inc 10 kA (SCPD – gL fuse 63 A for In 25, 40 A; gL fuse 80 A for In 63 A)
Rated impulse withstand voltage (1,2/50) Uimp 4 kV
Power consumption 1W
Installation Terminals 2,5 mm2
Tightening torque 0,4 Nm
Ambient temperature with daily average <= 35°C -25…+60 °C
Storage temperature -40…+70 °C
Communication Protocol Modbus RS485
Baud rate 38400
Addresses 1…99
Dimensions and DIN modules 1
weight Weight 180 gr
2/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCCBs
F-ATI and F-ARI
F-ATI
F-ARI 4 Test
F-ARI Test
2
—
RCCBs
F-ATI and F-ARI
Gamma ARBus
ARBus
2/42 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCD-blocks
DDA 200 technical features
Standards
DDA 200 3P
4P
Insulation voltage Ui [V]
Operating voltage of circuit test Ut 2P [V]
3P
4P
Rated frequency Hz
Rated breaking capacity according to IEC EN 61009 [A]
Rated breaking capacity according to IEC EN 60947-2 [A]
Rated residual breaking capacity I∆m [kA]
Rated inpulse withstand capacity (1,2/50) Uimp [kV]
Dielectric test voltage at ind. freq. for 1 min. [kV]
Surge current resistance (wave 8/20) [A]
a All RCD-blocks DDA 200 with rated current 63 A are provided with two additional terminals for remote tripping.
b DDA200 A AE is provided with two additional terminals for remote release in positive safety.
A remote control circuit should be connected to those terminals where circuit breakers or push buttons
with normally closed contacts should be inserted.
2/43
2
—
RCD-blocks
DDA 200 technical features
DDA 200 AC DDA 200 A DDA 200 A AP-R DDA 200 A AE DDA 200 A S DDA 200 B
IEC/EN 61009-1 Ann. G; IEC/EN 61009-2-1 IEC/EN 61009-1 Ann. G;
IEC/EN 61009-2-1,
IEC EN 62423
AC A A A A B
25, 40, 63 a 25, 40, 63 a 63 b 63 a 25-40-63
2P, 3P, 4P 2P, 3P, 4P
230 (400 for special execution @400 V) 230 230 230
230/400 400 400 400
230/400 230/400 230/400 230/400
500
110-254 for special execution @110V; 184-264 195-254 (170-254 for 30 195-254 (170-254 for 30
195-254 (170-254 for 30 mA; 400 for special execution @400 V) mA) mA)
195-440 (300-440 for 30 mA; 110-254 for special execution @110 V) 310-440 195-440 (300-440 for 310-440 (300-440 for 30
30 mA) mA)
195-440 (300-440 for 30 mA; 110-254 for special execution @110 V) 184-264 195-440 (300-440 for 195-254 (300-440 for 30
30 mA) mA)
50…60
same of the coupled MCB
same of the coupled MCB
same of the coupled MCB
4
2,5
3000 (5000 for selective
NA 3000 NA 5000
types)
0.01-0.03-0.1-0.3-0.5-1 0.03 0.03-0.3-0.5-1 0.1-0.3-0.5-1 0.03 - 0.3 - 0.5
blue
10000
20000
IP4X
IP2X
28 cycles with 55°C/90-96% and 25°C/95-100%
-25...+55
-40…+70
bi-directional cylinder-lift
cage type -
bi-directional cylinder-lift
(rigid or flexible) up to 25
(rigid or flexible) up to 16 -
(rigid or flexible) up to 25
2.8
1.2 -
2.8
on DIN rail EN 60715 (35 mm) by means of fast clip device
Any
85 x 69 x 35 85 x 69 x 70
85 x 69 x 35 85 x 69 x 70
85 x 69 x 70 85 x 69 x 70
175 350
175 375
325 395
yes
yes
yes
yes
2/4 4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCD-blocks
DDA 200 series AC w type
version with test button working at 110VAC - 254VAC is available. For selection tables refer to special version paragraph.
provided with additional terminals for remote tripping
2/45
2
—
RCD-blocks
DDA 200 series AC w type
version with test button working at 110VAC - 254VAC is available. For selection tables refer to special version paragraph.
provided with additional terminals for remote tripping
2/46 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCD-blocks
DDA 200 series A y type
version with test button working at 110VAC - 254VAC is available. For selection tables refer to special version paragraph.
provided with additional terminals for remote tripping
2/47
2
—
RCD-blocks
DDA 200 series A y type
version with test button working at 110VAC - 254VAC is available. For selection tables refer to special version paragraph.
provided with additional terminals for remote tripping
2/48 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCD-blocks
DDA 200 special version 110 V and 400 V
110 V version
AC type
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 8012542 1 piece 1 piece unit
current
DDA 203 IDn mA In A EAN Type code Order code kg pc.
4 30 63 a 929901 DDA 204 AC- 2CSB204099R1630 0.350 1
63/0.03 110V
A type
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 8012542 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
2 30 25 079033 DDA202 A-25/0.03 2CSB202199R1250 0.180 1
110V
40 078937 DDA202 A-40/0.03 2CSB202199R1400 0.180 1
110V
63 a 078838 DDA202 A-63/0.03 2CSB202199R1630 0.180 1
110V
DDA 204
3 30 40 811701 DDA 203 A-40/0.03 2CSB203199R1400 0.350 1
110V
63 a 811800 DDA 203 A-63/0.03 2CSB203199R1630 0.350 1
110V
4 30 63 a 812104 DDA 204 A-63/0.03 2CSB204199R1630 0.350 1
110V
400 V version
A type
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 8012542 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
2 30 63 a 954934 DDA 202 A-63/0.03 2CSB202192R1630 0.200 1
400V
2
—
RCD-blocks
DDA 200 series A y type, AP-R (high immunity)
—
RCD-blocks
DDA 200 series A y type, AE (for emergency stop)
DDA 204
2
—
RCD-blocks
DDA 200 series A y type, selective
Attention: All DDA 200 A S are provided with additional terminals for remote tripping
2/52 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCD-blocks
DDA 200 series B y type
2
—
RCD-blocks
DDA 200 series B y type
—
RCD-blocks
DDA 800 technical features
Standards
Electrical Type (wave form of the earth leakage sensed)
features Poles
Rated current In A
Rated sensitivity IDn A
DDA 800
Rated voltage Ue V
Insulation voltage Ui V
Operating voltage of circuit test Ut V
Rated frequency Hz
Rated breaking capacity (Icn) acc. to IEC /EN 60947-2 A
Rated residual breaking capacity IDm with S 800 C kA
with S 800 N kA
with S 800 S kA
Rated impulse withstand voltage (1.2/50) Uimp kV
Dielectric test voltage at ind. freq. for 1 min. kV
Surge current resistance (wave 8/20) A
Mechanical Toggle
features Electrical life
Mechanical life
Protection degree housing
terminals
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 °C/RH
Ambient temperature (with daily average ≤ +35 °C) °C
Storage temperature °C
Terminal size for cables flexible mm2
rigid mm2
Tightening torque Nm
Mounting
Dimensions Dimensions (H x D x W) 2P mm
and weight 3P mm
4P mm
Weight 2P g
3P g
4P g
Combination Combinable with: S 800 N
with MCBs S 800 S
2
—
RCD-blocks
DDA 800 technical features
DDA 800 AC DDA 800 A DDA 800 A AP-R DDA 800 A S
IEC/EN 60947-2 Ann. B
AC A A A
2P, 3P, 4P
63 63 100 63-100 63 100
0.03-0.3 0.03-0.3-0.5 0.3-0.5 0.03 0.3-1 0.3-0.5*-1
230/400 - 240/415 - 400/690
690
195-690
50...60
according to the breaking capacity of the associated MCB
according to the Icu of the associated MCB
according to the Icu of the associated MCB
according to the Icu of the associated MCB
6
2.5
NA 3000 5000
blue operating just from OFF position
10000
20000
IP4X
IP2X
28 cycles with 55°C/90-96% and 25°C/95-100%
-25...+60
-40...+70
6...50
6...70
min. 3 / max. 4
on DIN rail EN 60715 (35 mm) by means of rapid fixing device
108.2 x 82.3 x 81
108.2 x 82.3 x 117
108.2 x 82.3 x 117
300 for 63 A - 415 for 100 A
400 for 63 A - 640 for 100 A
460 for 63 A - 765 for 100 A
yes
yes
2/56 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCD-blocks
DDA 800 AC w type for MCBs S800
DDA 803 Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 8012542 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
3 30 63 922001 DDA803AC-63/0.03 2CSB803001R1630 0.400 1
300 63 922209 DDA803AC-63/0.3 2CSB803001R3630 0.400 1
2
—
RCD-blocks
DDA 800 A y type for MCBs S800
—
RCD-blocks
DDA 800 A y type AP-R (high immunity) for MCBs S800
2
—
RCD-blocks
DDA 800 A y type selective for MCBs S800
—
2
RCBO DS201
Compact solutions for a complete
protection
Easy to install
Bi-directional cylindrical
terminal ensure higher
safety of connecting
operations, making them
easier.
Anti counterfeiting
DS201 is equipped
with a tag RFid in order
to authenticate the product.
Test pushbutton
Test pushbutton to verify
Laser printed information
the correct functioning
Information on the device
of the device.
are laser printed to ensure
readability over time.
2
Easy installation Mounting clip
The terminals available on DS201 make easier the Stable fixing on DIN rail, easy and fast mounting
supply operation in parallel with cables and and dismounting operations thanks to the
busbars as they are composed by two different standard mounting clip.
seats: a front seat for 25 mm2 cables and a back
seat for 10 mm2 busbars. Supply is possible either
from top or bottom side.
—
RCBOs
DS201 technical features
DS201 L DS201
Standards IEC/EN 61009-1; IEC/EN 61009-2-1 IEC/EN 61009-1; IEC/EN 61009-2-1
Electrical Type (wave form of the earth leakage sensed) A - AC - APR A - AC - APR
features Number of poles 1P + N 1P + N
Rated current In A 6 ≤ In ≤ 32 1 ≤ In ≤ 40
Rated sensitivity I∆n A 0.01 - 0.03 - 0.3 0.01 - 0.03 - 0.1 - 0.3
Rated voltage Ue V 230-240 230-240
Insulation voltage Ui V 500 V AC 500 V AC
Overvoltage category III III
Pollution degree 2 2
Operating voltage of circuit test V 110 (170 for 30mA) - 264 110 (170 for 30mA) - 264
Ut
Rated frequency Hz 50/60 50/60
Rated breaking capacity Icn A 4500 6000
acc. to IEC/EN 61009-1
Rated breaking capacity ultimate Icu kA 6 10
acc. to IEC/EN 60947-2 (only service Ics kA 4.5 7.5
referring to short circuit test)
Rated residual breaking capacity I∆m A 4500 6000
I∆m according to EN 61009-1
Rated residual breaking capacity I∆m A 4500 6000 up to 25 A; 4500 for 32A and
I∆m according to IEC 61009-1 40A
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 1 min.) 2.5 kV (50 / 60Hz, 1 min.)
Thermomagnetic release - B: 3 In ≤ In ≤ 5 In ■
characteristic C: 5 In ≤ In ≤ 10 ■ ■
In
K: 10 In ≤ In ≤ 14 ■
In
Energy limiting class acc. to 3 3
EN 61009-1
Surge current resistance (wave A NA for A, AC versions; 3000 for APR NA for A, AC versions; 3000 for APR
8/20) version version
Mechanical Housing Insulation group I - II, RAL 7035 Insulation group I - II, RAL 7035
features Toggle Insulation group II, Black RAL 9005, Insulation group II, Black RAL 9005,
sealable in ON-OFF positions sealable in ON-OFF positions
Contact position indication Green/Red Window Green/Red Window
Earth fault trip indication Blue flag on toggle Blue flag on toggle
Electrical life operations 10000 10000
Mechanical life operations 20000 20000
Protection degree acc. to EN housing IP4X IP4X
60529 terminals IP2X IP2X
Shock resistance acc. to IEC/EN 25g - 2 shocks - 13ms 25g - 2 shocks - 13ms
60068-2-27
Vibration resistance acc. to IEC/EN 60068-2-6 0.1 mm or 1 g - 20 cycles at 0.1 mm or 1 g - 20 cycles at
5…150…5 Hz 5…150…5 Hz
Environmental conditions (damp heat) °C/RH 28 cycles with 55°C/90-96% and 28 cycles with 55°C/90-96% and
acc. to IEC/EN 60068-2-30 25°C/95-100% 25°C/95-100%
Reference temperature for setting of thermal °C 30 30 (20 for K tripping char)
element
Ambient temperature (with daily average ≤ +35 °C) °C -25…+55 -25…+55
Storage temperature °C -40…+70 -40…+70
2/63
2
—
RCBOs
DS201 technical features
15 15 10
11.2 11.2 7.5
6000 up to 25 A; 4500 for 32A and 40A 6000 up to 25 A; 4500 for 32A and 40A 6000 up to 25 A; 4500 for 32A and 40A
4 kV 4 kV 4 kV
2.5 kV (50 / 60Hz, 1 min.) 2.5 kV (50 / 60Hz, 1 min.) 2.5 kV (50 / 60Hz, 1 min.)
■ ■
■ ■ ■
3 NA 3
NA for A, AC versions; 3000 for APR and F version NA NA for A; 3000 for APR version
Insulation group I - II, RAL 7035 Insulation group I - II, RAL 7035 Insulation group I - II, RAL 7035
Insulation group II, Black RAL 9005, Insulation group II, Black RAL 9005, Insulation group II, Black RAL 9005,
sealable in ON-OFF positions sealable in ON-OFF positions sealable in ON-OFF positions
Green/Red Window Green/Red Window Green/Red Window
Blue flag on toggle Blue flag on toggle Blue flag on toggle
10000 10000 10000
20000 20000 20000
IP4X IP4X IP4X
IP2X IP2X IP2X
25g - 2 shocks - 13ms 25g - 2 shocks - 13ms 25g - 2 shocks - 13ms
0.1 mm or 1 g - 20 cycles at 5…150…5 Hz 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
28 cycles with 55°C/90-96% and 25°C/95-100% 28 cycles with 55°C/90-96% and 25°C/95-100% 28 cycles with 55°C/90-96% and 25°C/95-100%
—
RCBOs
DS201 technical features
DS201 L DS201
Installation Terminal type top / bottom failsafe bi-directional cylinder-lift failsafe bi-directional cylinder-lift
terminal (shock protected) terminal (shock protected)
Terminal size for cables top / bottom mm2 25/25 25/25
Terminal size for busbars top / bottom mm2 10/10 10/10
Tightening torque top / bottom Nm 2.8 2.8
Stripping length of the cable mm 12 12
Mounting on DIN rail EN 60715 (35mm) on DIN rail EN 60715 (35mm)
by means of mounting clip by means of mounting clip
Mounting position Any Any
Supply from Top/Bottom terminals Top/Bottom terminals
Dimensions Dimensions (H x D x W) mm 85 x 69 x 35 85 x 69 x 35
and weight Weight g 200 200
Combination Combinable with Auxiliary contact yes yes
with accessories and Signal contact / auxiliary yes yes
auxiliary auxiliaries contact
elements
Shunt trip yes yes
Auxiliary contact for bottom yes yes
fitting
Undervoltage release yes yes
Overvoltage release yes yes
Motor operating device yes yes
2/65
2
—
RCBOs
DS201 technical features
—
RCBOs
DS201 L series 4500 A y type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
2
—
RCBOs
DS201 L 4500 AC w type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating earth fault currents;
protection against indirect contact and additional protection against direct contact
(IΔn=30 mA).
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing an optimal trade-off between safety and continuity of service,
thanks to the resistance to unwanted tripping; protection against indirect contact and
additional protection against direct contact (IΔn=30mA); protection and isolation of
resistive and inductive loads.
—
RCBOs
DS201 6000 A y type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
2
—
RCBOs
DS201 T 6000 A y type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
—
RCBOs
DS201 6000 A y type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
2
—
RCBOs
DS201 T 6000 A y type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
—
RCBOs
DS201 6000 A y type, K characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
2
—
RCBOs
DS201 T 6000 A y type, K characteristics
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
—
RCBOs
DS201 6000 AC w type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating earth fault currents;
protection against indirect contact and additional protection against direct contact
(IΔn=30 mA).
2
—
RCBOs
DS201 6000 AC w type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating earth fault currents;
protection against indirect contact and additional protection against direct contact
(IΔn=30 mA).
—
RCBOs
DS201 6000 APR y type, C characteristic
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing an optimal trade-off between safety and continuity of service
thanks to the resistance to unwanted tripping; protection against indirect contact and
additional protection against direct contact (IΔn=30 mA); protection and isolation of
resistive and inductive loads.
2
—
RCBOs
DS201 T 6000 APR y type, C characteristic
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing an optimal trade-off between safety and continuity of service
thanks to the resistance to unwanted tripping; protection against indirect contact and
additional protection against direct contact (IΔn=30 mA); protection and isolation of
resistive and inductive loads.
—
RCBOs
DS201 M 10000 A y type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
2
—
RCBOs
DS201 M 10000 A y type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn=30 mA).
—
RCBOs
DS201 M 10000 A y type, K characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents.
DS201 M
2
—
RCBOs
DS201 M 10000 AC w type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating earth fault currents;
protection against indirect contact and additional protection against direct contact
(IΔn=30 mA).
—
RCBOs
DS201 M 10000 AC w type, C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating earth fault currents;
protection against indirect contact and additional protection against direct contact
(IΔn=30 mA).
2
—
RCBOs
DS201 M 10000 APR y type, C characteristic
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing an optimal compromise between safety and continuity of service,
thanks to the resistance to unwanted tripping; protection against indirect contact and
additional protection against direct contact (IΔn=30 mA); protection and isolation of
resistive and inductive loads.
—
RCBOs
DS201 T 6000 APR y type, B characteristic
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents, providing an optimal compromise between safety and continuity of service,
thanks to the resistance to unwanted tripping; protection against indirect contact and
additional protection against direct contact (IΔn=30 mA); protection and isolation of
resistive and inductive loads.
2
—
RCBOs
DS201 M 10000 F y type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit cur-
rents; protection against the effects of sinusoidal alternating earth fault currents; protec-
tion against indirect contact and additional protection against direct contact (IΔn=30 mA).
Specifically suitable for the protection of lines supplying single phase inverters.
Function: protection of end user single-phase circuits against overload and short-circuit cur-
rents; protection against the effects of sinusoidal alternating earth fault currents; protec-
tion against indirect contact and additional protection against direct contact (IΔn=30 mA).
Specifically suitable for the protection of lines supplying single phase inverters.
—
RCBOs
DS201 M 110V 10000 A y type, B characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn = 30 mA).
This particular series of devices has the minimum operating voltage of test button of
110 V and it is suitable for 230 V applications.
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn = 30 mA).
This particular series of devices has the minimum operating voltage of test button of
110 V and it is suitable for 230 V applications.
2
—
RCBOs
DS201 UL technical features
DS201 UL
Standards UL 1053, UL 1077,IEC 61009-1, IEC 61009-2-1
Electrical Type (wave form of the earth leakage sensed) A
features Number of poles 1P + N
Rated current In A 6 ≤ In ≤ 25
Rated sensitivity I∆n A 0.03
Rated voltage Ue V 230-240
Insulation voltage Ui V 500 V AC
Overvoltage category III
Pollution degree 2
Operating voltage of circuit test Ut V 110 – 264
Rated frequency Hz 50/60
Rated breaking capacity acc. to To UL 1053, IEC 61009-1, IEC Icn A 6 000
61009-2-1
Rated breaking capacity acc. to IEC 60947-2 ultimate Icu kA 10
service Ics kA 7.5
Rated residual breaking capacity I∆m A 6 000
I∆m according to IEC 61009-1
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 1 min.)
Thermomagnetic release - characteristic B: 3 In ≤ In ≤ 5 In ■
C: 5 In ≤ In ≤ 10 ■
In
Rated residual breaking capacity IΔm A 6 000
Surge current resistance (wave 8/20 μs) NA
Mechanical Housing Insulation group I - II, RAL 7035
features Toggle Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
Contact position indication Green/Red Window
Earth fault trip indication Blue flag on toggle
Electrical life operations 10000
Mechanical life operations 20000
Protection degree acc. to EN 60529 housing IP4X
terminals IP2X
Shock resistance acc. to IEC/EN 60068-2-27 25g - 2 shocks - 13ms
Vibration resistance acc. to IEC/EN 60068-2-6 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 °C / RH 28 cycles with 55°C/90-96% and 25°C/95-100%
Reference temperature for setting of thermal element °C / °F 30 / 86
Ambient temperature (with daily average ≤ +35 °C) °C / °F -25…+55 / -13…+131
Storage temperature °C / °F -40…+70 / -40…+158
Installation Terminal type top / bottom Failsafe bi-directional cylinder-lift terminal
(shock protected)
Terminal size for solid cables top / bottom mm2 / AWG 25/25 / 10/10
Terminal size for stranded cables top / bottom mm2 / AWG 16/16 / 6/6
These terminals are not suitable for copper compact stranded conductors
Terminal size for busbars top / bottom mm2 / AWG 10/8
Tightening torque top / bottom Nm / in.lb 2.8 / 24.5
Stripping length of the cable mm / in 12 / 0.5
Mounting on DIN rail EN 60715 (35mm)
by means of mounting clip
Mounting position Any
Supply from Top/Bottom terminals
Dimensions Dimensions (H x D x W) mm / in 85 x 69 x 35 / 3.34 x 2.71 x 1.37
and weight Weight g / lb 200 / 0.44
Combination Combinable with Auxiliary contact yes
with accessories and auxiliaries Signal contact / auxiliary contact yes
auxiliary
Shunt trip yes
elements
Auxiliary contact for bottom fitting yes
Undervoltage release yes
Overvoltage release yes
Motor operating device yes
N.B The combination is mechanically compatible with but no UL approved.
2/88 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS201 UL technical features
This particular series of devices is UL & CSA approved and is a supplementary protector.
This particular series of devices is UL & CSA approved and is a supplementary protector.
2
—
RCBOs
DS202C technical features
DS202C
DS202C DS202C M DS202C M
M 110V
Standards IEC 61009-1;
IEC/EN 61009-1; IEC/EN 61009-2-1
IEC 61009-2-1
Electrical Type (wave form of the earth leakage sensed) A A APR A
features Poles 2P 2P 2P 2P
Rated current In A 6 ≤ In ≤ 32 6 ≤ In ≤ 32 6 ≤ In ≤ 32 6 ≤ In ≤ 32
Rated sensitivity IDn A 0.03-0.3 0.01-0.03-0.3 0.03-0.3 0.03
Rated voltage Ue V 230-240 230-240 230-240 230-240
Insulation voltage Ui V 500 500 500 500
Operating voltage of circuit test Ut V 110 (170 for 110 (170 for 110 (170 for 110-254
30 mA) - 254 30 mA) - 254 30 mA) - 254
Rated frequency Hz 50…60 50…60 50…60 50…60
Rated breaking capacity acc. to ultimate Icn A 6000 10000 10000 10000
IEC/EN 61009
Rated breaking capacity acc. to ultimate Icu kA 10 10 10 10
IEC/EN 60947-2
2P @230 VAC service Ics kA 6 7.5 7.5 7.5
Rated residual breaking capacity IDm kA 6 6 6 6
Rated impulse withstand voltage (1.2/50) Uimp kV 4 4 4 4
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 2.5 2.5 2.5
Thermomagnetic release B: 3 In ≤ Im ≤ 5 In n n n
characteristic
C: 5 In ≤ Im ≤ 10 In n n n n
Surge current resistance (wave 8/20) A NA for A, AC versions; 3000 for APR version
Mechanical Toggle black sealable in ON-OFF position
features Flag indicators differential trip indicator (blue)
contact position indicator (green/red)
Electrical life 10000 10000 10000 10000
Mechanical life 20000 20000 20000 20000
Protection degree housing IP4X IP4X IP4X IP4X
terminals IP2X IP2X IP2X IP2X
Environmental conditions (damp heat) °C/RH 28 cycles with 55°C/90-96% and 25°C/95-100%
acc. to IEC/EN 60068-2-30
Reference temperature for setting of thermal element °C 30 30 30 30
Ambient temperature (with daily average ≤ +35 °C) °C -25…+55 -25…+55 -25…+55 -25…+55
Storage temperature °C -40…+70 -40…+70 -40…+70 -40…+70
Installation Terminal type top failsafe bi-directional cylinder-lift terminal at top and bottom
(shock protected)
bottom failsafe bi-directional cylinder-lift terminal at top and bottom
(shock protected)
Terminal size top/bottom for cables mm2 25/25 25/25 25/25 25/25
Terminal size top/bottom for busabar mm2 10/10 10/10 10/10 10/10
Tightening torque top/bottom Nm 2.8 2.8 2.8 2.8
Mounting on DIN rail EN 60715 (35 mm) by means of fast clip device
Mounting position Any Any Any Any
Connection from top and from top and from top and from top and
bottom bottom bottom bottom
Dimensions Dimensions (H x D x W) mm 85 x 69 x 35 85 x 69 x 35 85 x 69 x 35 85 x 69 x 35
and weight Weight g 239 239 239 239
Combination Combinable with: auxiliary contact yes yes yes yes
with signal contact yes yes yes yes
auxiliary
elements shunt trip yes yes yes yes
undervoltage release yes yes yes yes
2/90 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS202C series 6000 A y type, B characteristic
2
—
RCBOs
DS202C series 6000 A y type, C characteristic
—
RCBOs
DS202C M series 10000 A y type, B characteristic
2
—
RCBOs
DS202C M series 10000 A y type, C characteristic
—
RCBOs
DS202C M series 10000 A y APR type, B characteristic
2
—
RCBOs
DS202C M series 10000 APR type, C characteristic
—
RCBOs
DS202C M 110V series 10000 A y type, C characteristic
2
—
Notes
2/98 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
—
2
Terminals designed
Compact size for easy to ease the
installation in small spaces installation.
and retrofitting of already
existing facilities.
Test pushbutton
to verify the correct
functioning of the
device.
Operating toggle
The indication of the
can be sealed into
status of the contacts is
on/off position
done with a mechanical
to ensure
connection to the mobile
maintenance
contacts and
in complete safety.
independently from the
toggle position.
The contacts position
indicator (CPI) allows to
exactly know the status of
the contacts of the device
(green: open contacts, red:
closed contacts).
Space for
identification
labels of the
protected
line. Same profile as the
System pro M compact®
range.
2/99
2
Use with cables and with busbars RFid Differential trip indicator
Terminals with two slots allow to use Radio frequency tracking via a radio In case of tripping due to earth fault,
different types of conductors: one frequency tag to facilitate logistics a blue flag appears on the toggle thus
housing is designed for cables up to and to be assured of the originality immediate showing the cause of trip of
25 mm2, the other for busbars or cables of the product. the device. This feature helps in trou-
up to 10 mm2. bleshooting on the network and re-
duces the downtime for maintenance.
—
RCBOs
DS203NC technical features
DS203NC L DS203NC
Standards IEC/EN 61009-1; IEC/EN 61009-2-1 IEC/EN 61009-1; IEC/EN 61009-2-1
Electrical features
Type (wave form of the earth AC, A, APR AC, A, APR, S
leakage sensed)
Number of poles 3P+N 3P+N
Rated current In A 6≤ In ≤ 32A 6≤ In ≤ 32A
Rated sensitivity IDn mA 30-300 30-100-300
Rated voltage Ue V 400-415V 400-415V
Insulation voltage Ui V 500 V AC 500 V AC
Overvoltage category III III
Pollution degree 2 2
Operating voltage of circuit test Ut V 195 (300 for 30 mA) - 440
Rated frequency Hz 50/60 50/60
Rated breaking ultimate Icn A 4500 6000
capacity acc. to IEC/ EN 61009
Rated breaking ultimate Icu kA 6 10
capacity acc. to IEC/EN 60947-2
Thermomagnetic release - B: 3 In ≤ Im ≤ 5 In n
characteristic
C: 5 In ≤ Im ≤ 10 In n n
K: 10 In ≤ Im ≤ 14 In n
Surge current resistance (wave 8/20) A NA for A, AC versions; 3000 for APR NA for A, AC versions; 3000 for APR
version version; 5000 for S version
Mechanical features
Housing Insulation group II, RAL 7035 Insulation group II, RAL 7035
Toggle black, sealable in ON-OFF positions black, sealable in ON-OFF positions
Flag indicator Differential trip indicator: Differential trip indicator:
blue on toggle blue on toggle
Environmental conditions (damp heat) acc. to IEC/EN °C/RH 28 cycles with 55°C/90-96% and 28 cycles with 55°C/90-96% and
60068-2-30 25°C/95-100% 25°C/95-100%
2
—
RCBOs
DS203NC technical features
DS203NC L DS203NC
Installation
Terminal type top/ bottom failsafe bi-directional cylinder-lift failsafe bi-directional cylinder-lift
terminal (shock protected) terminal (shock protected)
—
RCBOs
DS203NC L AC w
2
—
RCBOs
DS203NC L A y type
—
RCBOs
DS203NC L APR type
2
—
RCBOs
DS203NC AC w type
—
RCBOs
DS203NC AC w type
2
—
RCBOs
DS203NC A y type
—
RCBOs
DS203NC A y type
2
—
RCBOs
DS203NC A y type
—
RCBOs
DS203NC APR type
2
—
RCBOs
DS203NC A y S type
—
RCBOs
DS 200 technical features
Standards
Electrical Operating characteristic: type (wave form of the earth leakage sensed)
features Poles
Rated sensitivity IDn A
Rated current In A
Rated voltage Ue 2P V
DS 200
3P, 4P V
Insulation voltage Ui V
Operating voltage of circuit test Ut 2P V
3P V
4P V
Rated frequency Hz
Rated breaking capacity acc. to IEC/EN 61009 ultimate Icn A
Rated breaking capacity ultimate Icu kA
acc. to IEC/EN 60947-2 1P+N @230 VAC, 2P, 3P, 4P @400 service Ics kA
VAC
Rated residual breaking capacity I∆m kA
Rated impulse withstand voltage (1.2/50) Uimp kV
Dielectric test voltage at ind. freq. for 1 min. kV
Overvoltage category
Thermomagnetic release B: 3 In ≤ Im ≤ 5 In
characteristic
C: 5 In ≤ Im ≤ 10 In
K: 10 In ≤ Im ≤ 14 In
Surge current resistance (wave 8/20) A
Mechanical Toggle 2P, 3P, 4P
features Contact position indication
Electrical life
Mechanical life
Protection degree housing
terminals
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 °C/RH
Reference temperature for setting of thermal element °C
Ambient temperature (with daily average ≤ +35 °C) °C
Storage temperature °C
Installation Terminal type top
bottom 2P
3P/4P In ≤ 40 A
3P/4P 50 A ≤ In ≤ 63 A
Terminal size top/bottom per cable 2P mm2
3P/4P In ≤ 40 A mm2
3P/4P 50 A ≤ In ≤ 63 A mm2
Tightening torque top/bottom 2P Nm
3P/4P In ≤ 40 A Nm
3P/4P 50 A ≤ In ≤ 63 A Nm
Mounting
Mounting position
Connection
a Available depending on type and characteristic curve. For 2P RCBOs A type B-C curves up to 32 A, refer to DS202C 2 protected poles
RCBOs in only two modules
b Prior to connection of aluminium conductors (≥ 4 mm2) ensure that their contact points are cleaned, brushed and coated with
grease
2/113
2
—
RCBOs
DS 200 technical features
6 6 10 10
6
2.5
III, disconnector abilities
n n n n
n n n n
n
NA
black (MCB) sealable in ON-OFF position + blue (RCD)
CPI on window
10000
20000
IP4X
IP2X
28 cycles with 55°C/90-96% and 25°C/95-100%
30
-25…+55
-40…+70
failsafe bidirectional cylinder-lift terminal (shock protected) b
failsafe bidirectional cylinder-lift terminal (shock protected) b
cage (shock protected)
failsafe bidirectional cylinder-lift terminal (shock protected) b
rigid: 35/25 flexible: 25/25
rigid: 35/25 flexible: 25/16
rigid : 35/25 flexible : 25/25
2.8/2.8
2.8/1.2
2.8/2.8
on DIN rail EN 60715 (35 mm) by means of fast clip device
Any
715 (35 mm) by means of fast clip devicefrom top and bottom
2/114 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS 200 technical features
Dimensions Dimensions (H x D x W) 2P mm
and weight 3P In ≤ 40 A mm
4P In ≤ 40 A mm
3P 50 A ≤ In ≤ 63 A mm
4P 50 A ≤ In ≤ 63 A mm
Weight 2P g
DS 200
3P In ≤ 40 A g
4P In ≤ 40 A g
3P 50 A ≤ In ≤ 63 A g
4P 50 A ≤ In ≤ 63 A g
Combination Combinable with: auxiliary contact
with signal contact/auxiliary
auxiliary switch
elements
shunt trip
undervoltage release
2/115
2
—
RCBOs
DS 200 technical features
yes
yes
2/116 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS 201 series 6000 - AC w type, B characteristic
2
—
RCBOs
DS 200 series 6000 - AC w type, C characteristic
—
RCBOs
DS 200 series 6000 - A y type, B characteristic
2
—
RCBOs
DS 200 series 6000 - A y type, C characteristic
—
RCBOs
DS 200 series 6000 - A y type, K characteristic
2
—
RCBOs
DS 200 M series 10000 - AC w type, B characteristic
—
RCBOs
DS 200 M series 10000 - AC w type, C characteristic
2
—
RCBOs
DS 200 M series 10000 - A y type, B characteristic
—
RCBOs
DS 200 M series 10000 - A y type, C characteristic
2
—
RCBOs
DS 200 M series 10000 - A y type, C characteristic
—
RCBOs
DS800 technical features
Standards
Electrical Operating characteristic: type (wave form of the earth leakage sensed)
features Poles
Rated sensitivity IDn A
DS800S Rated current In A
Rated voltage Ue V
Insulation voltage Ui V
Operating voltage of circuit test Ut V
Rated frequency Hz
Rated ultimate short-circuit breaking capacity Icu 240/415 V AC kA
254/440 V AC kA
289/500 V AC kA
400/690 V AC kA
Rated service short-circuit breaking capacity Ics 240/415 V AC kA
254/440 V AC kA
289/500 V AC kA
400/690 V AC kA
Rated impulse withstand voltage (1.2/50) Uimp kV
Dielectric test voltage at ind. freq. for 1 min. kV
Thermomagnetic release B: 3 In ≤ Im ≤ 5 In
characteristic
C: 5 In ≤ Im ≤ 10 In
D**: 10 In ≤ Im ≤ 20 In
K**: 8 In ≤ Im ≤ 14 In
Surge current resistance acc. to VDE 0432 Part 2 (wave 8/20) A
Mechanical Toggle
features Electrical life
Mechanical life
Protection degree housing
terminals
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 °C/RH
Ambient temperature (with daily average ≤ + 35 °C) °C
Storage temperature °C
Installation Terminal size for cables flexible mm2
rigid mm2
Tightening torque Nm
Mounting
Dimensions Dimensions (H x D x W) 2P mm
and weight 3P mm
4P mm
Weight 2P g
3P g
4P g
Combination Combinable with: auxiliary contact
with signal contact/auxiliary
auxiliary switch
elements
shunt trip
undervoltage release
2
—
RCBOs
DS800 technical features
DS800S A DS800N A DS800S A S DS800N A S DS800S A AP-R DS800N A AP-R
IEC/EN 60947-2
A A A
2P, 3P, 4P 2P,4P 2P, 3P, 4P
0.3 0.3-1(*) 0.03
125
230/400-240/415-400/690
690
195-690
50…60
50 36 50 36 50 36
30 20 30 20 30 20
10 10 10 10 10 10
4.5 4.5 4.5 4.5 4.5 4.5
40 30 40 30 40 30
15 10 15 10 15 10
5 5 5 5 5 5
3 3 3 3 3 3
6
2.5
n n n n n n
n n n n n n
n n n n n n
n n n
NA NA 5000 5000 3000 3000
black (MCB) sealable in ON-OFF position + blue (RCD) operating just from OFF position
10000
20000
IP4X
IP2X
28 cycles with 55°C/90-96% and 25°C/95-100%
-25…+60
-40…+70
6…50
6…70
min. 3 / max. 4
on DIN rail EN 60715 (35 mm) by means of rapid fixing device
108,2 x 82,3 x 133.5
108,2 x 82,3 x 196
108,2 x 82,3 x 223
790
1140
1440
yes
yes
yes
yes
2/128 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS800S series 50000 A y type B, C, D and K characteristic
DS800S, A type
Function: protection against overload and short-circuit currents; protection against the
effects of sinusoidal alternating earth fault currents; protection against indirect contacts;
command and isolation of resistive and inductive loads.
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
2 B 300 125 211721 DS802S- 2CCA862005R0845 0.790 1
B125/0.3A
DS803S
C 300 125 211738 DS802S- 2CCA862005R0844 0.790 1
C125/0.3A
D 300 125 211745 DS802S- 2CCA862005R0841 0.790 1
D125/0.3A
K 300 125 211752 DS802S- 2CCA862005R0647 0.790 1
K125/0.3A
Number Curve Rated Rated Bbn Order details Price Weight Pack
DS804S of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
3 B 300 125 211769 DS803S- 2CCA863005R0845 1.14 1
B125/0.3A
C 300 125 211776 DS803S- 2CCA863005R0844 1.14 1
C125/0.3A
D 300 125 211783 DS803S- 2CCA863005R0841 1.14 1
D125/0.3A
K 300 125 211790 DS803S- 2CCA863005R0647 1.14 1
K125/0.3A
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 B 300 125 211806 DS804S- 2CCA864005R0845 1.44 1
B125/0.3A
C 300 125 211813 DS804S- 2CCA864005R0844 1.44 1
C125/0.3A
D 300 125 211820 DS804S- 2CCA864005R0841 1.44 1
D125/0.3A
K 300 125 211837 DS804S- 2CCA864005R0647 1.44 1
K125/0.3A
2/129
2
—
RCBOs
DS800N series 36000 A y type B, C and D characteristics
DS800N, A type
Function: protection against overload and short-circuit currents; protection against the
effects of sinusoidal alternating earth fault currents; protection against indirect contacts;
command and isolation of resistive and inductive loads.
Application: industrial.
DS802N
Standard: IEC/EN 60947-2
Icu = 36 kA
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
2 B 300 125 211844 DS802N- 2CCA892005R0845 0.790 1
B125/0.3A
DS803N
C 300 125 211851 DS802N- 2CCA892005R0844 0.790 1
C125/0.3A
D 300 125 211868 DS802N- 2CCA892005R0841 0.790 1
D125/0.3A
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
DS804N 3 B 300 125 211875 DS803N- 2CCA893005R0845 1.14 1
B125/0.3A
C 300 125 211882 DS803N- 2CCA893005R0844 1.14 1
C125/0.3A
D 300 125 211899 DS803N- 2CCA893005R0841 1.14 1
D125/0.3A
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 B 300 125 211905 DS804N- 2CCA894005R0845 1.44 1
B125/0.3A
C 300 125 211912 DS804N- 2CCA894005R0844 1.44 1
C125/0.3A
D 300 125 211929 DS804N- 2CCA894005R0841 1.44 1
D125/0.3A
2/130 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS800S series 50000 A y type selective B, C, D and K characteristics
Application: industrial.
Standard: IEC/EN 60947-2
Icu = 50 kA
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
DS803S IDn mA In A EAN Type code Order code kg pc.
2 B 1000 125 211516 DS802S- 2CCC862006R0845 0.790 1
B125/1AS
C 1000 125 211523 DS802S- 2CCC862006R0844 0.790 1
C125/1AS
D 1000 125 211530 DS802S- 2CCC862006R0841 0.790 1
D125/1AS
K 1000 125 211547 DS802S- 2CCC862006R0647 0.790 1
K125/1AS
DS804S
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 B 300 125 211554 DS804S- 2CCC864005R0845 1.44 1
B125/0.3AS
1000 125 211592 DS804S- 2CCC864006R0845 1.44 1
B125/1AS
C 300 125 211561 DS804S- 2CCC864005R0844 1.44 1
C125/0.3AS
1000 125 211608 DS804S- 2CCC864006R0844 1.44 1
C125/1AS
D 300 125 211578 DS804S- 2CCC864005R0841 1.44 1
D125/0.3AS
1000 125 211615 DS804S- 2CCC864006R0841 1.44 1
D125/1AS
K 300 125 211685 DS804S- 2CCC864005R0647 1.44 1
K125/0.3AS
1000 125 211622 DS804S- 2CCC864006R0647 1:44 1
K125/1AS
2/131
2
—
RCBOs
DS800N series 36000 A y type selective B, C and D characteristics
Application: industrial.
Standard: IEC/EN 60947-2
Icu = 36 kA
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
DS803N
2 B 1000 125 211639 DS802N- 2CCC892006R0845 0.790 1
B125/1AS
C 1000 125 211646 DS802N- 2CCC892006R0844 0.790 1
C125/1AS
D 1000 125 211653 DS802N- 2CCC892006R0841 0.790 1
D125/1AS
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
DS804N
current
IDn mA In A EAN Type code Order code kg pc.
4 B 300 125 211660 DS804N- 2CCC894005R0845 1.44 1
B125/0.3AS
1000 125 211691 DS804N- 2CCC894006R0845 1.44 1
B125/1AS
C 300 125 211677 DS804N- 2CCC894005R0844 1.44 1
C125/0.3AS
1000 125 211707 DS804N- 2CCC894006R0844 1.44 1
C125/1AS
D 300 125 211684 DS804N- 2CCC894005R0841 1.44 1
D125/0.3AS
1000 125 211714 DS804N- 2CCC894006R0841 1.44 1
D125/1AS
2/132 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
RCBOs
DS800S series 50000 A y type, AP-R (high immunity) B, C, D and K characteristics
Application: industrial.
Standard: IEC/EN 60947-2
Icu = 50 kA
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
DS803S
2 B 30 125 211301 DS802SB125 2CCB862004R0845 0.790 1
/.03AP-R
C 30 125 211318 DS802SC125 2CCB862004R0844 0.790 1
/.03AP-R
D 30 125 211325 DS802SD125 2CCB862004R0841 0.790 1
/.03AP-R
K 30 125 211332 DS802SK125 2CCB862004R0647 0.790 1
/.03AP-R
DS804S
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
3 B 30 125 211349 DS803SB125 2CCB863004R0845 1.14 1
/.03AP-R
C 30 125 211356 DS803SC125 2CCB863004R0844 1.14 1
/.03AP-R
D 30 125 211363 DS803SD125 2CCB863004R0841 1.14 1
/.03AP-R
K 30 125 211370 DS803SK125 2CCB863004R0647 1.14 1
/.03AP-R
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 B 30 125 211387 DS804SB125 2CCB864004R0845 1.44 1
/.03AP-R
C 30 125 211394 DS804SC125 2CCB864004R0844 1.44 1
/.03AP-R
D 30 125 211400 DS804SD125 2CCB864004R0841 1.44 1
/.03AP-R
K 30 125 211417 DS804SK125 2CCB864004R0647 1,44 1
/.03AP-R
2/133
2
—
RCBOs
DS800N series 36000 A y type, AP-R (high immunity) B, C and D characteristics
Application: industrial.
Standard: IEC/EN 60947-2
Icu = 36 kA
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
DS803N
2 B 30 125 211424 DS802NB125 2CCB892004R0845 0.790 1
/.03AP-R
C 30 125 211431 DS802NC125 2CCB892004R0844 0.790 1
/.03AP-R
D 30 125 211448 DS802ND125 2CCB892004R0841 0.790 1
/.03AP-R
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
DS804N
current
IDn mA In A EAN Type code Order code kg pc.
3 B 30 125 211455 DS803NB125 2CCB893004R0845 1.14 1
/.03AP-R
C 30 125 211462 DS803NC125 2CCB893004R0844 1.14 1
/.03AP-R
D 30 125 211479 DS803ND125 2CCB893004R0841 1.14 1
/.03AP-R
Number Curve Rated Rated Bbn Order details Price Weight Pack
of poles residual current 7612271 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
4 B 30 125 211486 DS804NB125 2CCB894004R0845 1.44 1
/.03AP-R
C 30 125 211493 DS804NC125 2CCB894004R0844 1.44 1
/.03AP-R
D 30 125 211509 DS804ND125 2CCB894004R0841 1.44 1
/.03AP-R
2/134 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
—
2
Product coding
All the necessary technical and
installation information can be
found directly on the device.
Product range, tripping
characteristics, rated currents,
sensitivity, type, breaking Anti counterfeiting
capacity, rated voltage, Each DSE201 is equipped with
order code, EAN code, electrical a RFID tag containing a unique
scheme, reference standards serial number assigned by ABB
and many other specifications according to ISO/IEC FCD
are laser printed on the front 15693-3 standard in order to
and side of units. authenticate the product.
Through this unique serial
number, ABB can easily
identify counterfeited
products and verify the
authenticity of each single
device.
In control
Test button allows the regular
check of the functionality of
Real contact position
the device: to be pushed every
indicator on toggle
six months.
Directly connected to the
moving contact of the
device, it indicates the
exact position of the
contacts at all times (red: Reduced height
closed contacts, green: Thanks to its reduced height,
open contacts). only 100 mm, DSE201 makes
easier wiring operation inside
the consumer unit or the
distribution board.
2/135
2
With its breaking capacity of 6kA in only one module width these devices are essential for the safety of people, utili-
and 100mm height, the DSE201 series is the perfect solu- ties and equipment, protecting not only against earth fault
tion for a complete protection in residential and light com- residual currents - due to loss of isolation or accidental
mercial applications. At home, in the office or in a shop, contact with live parts - but also against overcurrents.
—
DSE201
Technical features and overall dimensions
Electrical features
Standards IEC 61009-1; IEC 61009-2-2; AS/NZS 61009
Type (wave form of the earth leakage sensed) AC, A
Number of poles 1P+N
Rated current I n A 6≤ In ≤ 50
Rated sensitivity I Δn mA 30
Rated voltage U e V 230-240
Insulation voltage U i V 500 V AC
Overvoltage category III
Pollution degree 2
Max. operating voltage V 264
Min. operating voltage for protection against V 85
IΔn residual sinusoidal alternating currents
Operating voltage of circuit test V 195 - 264
Rated frequency Hz 50/60
Rated breaking capacity acc. to IEC 61009 ultimate I cn A 6000
Rated residual breaking capacity I Δm kA 6
Rated impulse withstand voltage (1.2/50) U imp kV 4 kV (test voltage 6.2kV at sea level, 5kV at 2000m)
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 1 min.)
Thermomagnetic release - characteristic B: 3 I n ≤ I m ≤ 5 I n n
C: 5 I n ≤ I m ≤ 10 I n n
Surge current resistance (wave 8/20) A NA
Mechanical data
Housing insulation group II, RAL 7035
Toggle insulation group IIIA, black, sealable in ON-OFF positions
Contact position indication CPI on toggle (I ON / 0 OFF)
Electrical life operations 10000
Mechanical life operations 20000
Protection degree housing IP4X
terminals IP2X
Shock resistance acc. to IEC/EN 60068-2-27 30g - 2 shocks - 13ms
Vibration resistance acc. to IEC/EN 60068-2-6 0.35mm or 5g - 20 cycles at 5…150…5 Hz without load
Environmental conditions (damp heat) °C/RH 28 cycles with 55°C/90-96% and 25°C/95-100%
acc. to IEC/EN 60068-2-30
2
—
DSE201
Technical features and overall dimensions
Installation
Terminal type top (load side) failsafe cage (shock protected)
bottom (line side) failsafe bi-directional cylinder-lift terminal
(shock protected)
Terminal size for cables load side (top) mm² 16
line side (bottom) mm² 25
Terminal size for busbars load side (top) only for wire connection
line side (bottom) mm² 10 (Standard ABB busbar / distribution board system)
Tightening torque top (load side) Nm 1.2
bottom (line side) Nm 2.8
Neutral load cable Type low smoke halogen free
Lenght mm 750
Section mm² 2.5 mm 2 up to 20 A; 4 mm 2 up to 50 A
Color blue
Functional earth cable Type low smoke halogen free
Lenght mm 750
Section mm² 0.75
Color white
Mounting on DIN rail EN 60715 (35 mm) by means of fast clip device in
consumer unit Type A according to IEC 61439-1&3, BS EN
61439-1&3, in distribution board Type B according to IEC
61439-1&3, BS EN 61439-1&3.
Supply from bottom terminal
Dimensions and weight
Dimensions (H x D x W) mm 100 x 68.9 x 17.6
Weight g 180
Combination with auxiliary elements
Combinable with accessories and auxiliaries no
2/138 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
eRCBOs
DSE201 series 6000 A y type, B and C characteristic
2
—
eRCBOs
DSE201 series 6000 AC w type, B and C characteristic
—
2
Combination with
auxiliary elements
A platform suitable Reduced height
for quick installation in Thanks to its reduced height,
combination with the only 115 mm, DSE201 M makes easier
standard auxiliary elements wiring operation inside the consumer
that can be mounted with unit or the distribution board.
RCDs and MCBs.
2/141
2
DSE201 M, unique solution
Distinctive features
With its breaking capacity of 10kA in only one module larly required. The unique earth fault indicator window
width and 115mm height, DSE201 M series is the perfect identifies any earth fault trip, making easier the trouble-
solution for a complete protection in commercial and in- shooting on the network and reducing the downtime for
dustrial applications, where space optimization is particu- maintenance.
—
DSE201 M
Technical features and overall dimensions
Electrical features
Standards IEC 61009-1 ; IEC 61009-2-2; BS EN 61009-1; AS/NZS
61009
Type (wave form of the earth leakage sensed) AC, A
Number of poles 1P+N
Rated current I n A 6≤ In ≤ 50
Rated sensitivity I Δn mA 10-30-100-300
Rated voltage U e V 230-240
Insulation voltage U i V 500 V AC
Overvoltage category III
Pollution degree 2
Max. operating voltage V 264
Min. operating voltage for protection against IΔn V 85
residual sinusoidal alternating currents
Operating voltage of circuit test V 195-264
Rated frequency Hz 50/60
Rated breaking capacity acc. to IEC 61009 ultimate I cn A 10000
Rated breaking capacity acc. to IEC 60947-2 ultimate I cu kA 15 ( for 6A ≤ In ≤ 40A)
kA 10 (for In = 50A)
service I cs kA 7.5
Rated residual breaking capacity I Δm kA 10
Rated impulse withstand voltage (1.2/50) U imp kV 4 kV (test voltage 6.2kV at sea level, 5kV at 2000m)
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50 / 60Hz, 1 min.)
Thermomagnetic release - characteristic B: 3 I n ≤ I m ≤ 5 I n n
C: 5 I n ≤ I m ≤ 10 I n n
Surge current resistance (wave 8/20) A NA
Mechanical data
Housing insulation group II, RAL 7035
Toggle insulation group II, black, sealable in ON-OFF positions
Earth fault indicator blue window
Contact position indication green/red Window
Electrical life operations 10000
Mechanical life operations 20000
Protection degree in enclosure with IP40
cover
terminals IP20
Shock resistance acc. to IEC/EN 60068-2-27 30g - 2 shocks - 13ms
Vibration resistance acc. to IEC/EN 60068-2-6 0.35mm or 5g - 20 cycles at 5…150…5 Hz without load
Environmental conditions (damp heat) °C/RH 28 cycles with 55°C/90-96% and 25°C/95-100%
acc. to IEC/EN 60068-2-30
2
—
DSE201 M
Technical features and overall dimensions
Installation
Terminal type top (load side) failsafe cage (shock protected)
bottom (line side) failsafe bi-directional cylinder-lift terminal (shock
protected)
Terminal size for cables load side mm² 16
line side (solid/ mm² 35/25
flexible)
Terminal size for busbars load side only for wire connection
line side mm² 10 (Standard ABB busbar / distribution board system)
Tightening torque top (load side) Nm 1.2
bottom (line side) Nm 2.8
Neutral load cable Type low smoke halogen free
Lenght mm 750
Section mm² 2.5 mm 2 up to 20 A; 4 mm 2 up to 50 A
Color blue
Functional earth cable Type low smoke halogen free
Lenght mm 750
Section mm² 0.75
Color white
Mounting on DIN rail EN 60715 (35 mm) by means of fast clip device in
consumer unit Type A according to IEC 61439-1&3, BS EN
61439-1&3 in distribution board Type B according to IEC
61439-1&3, BS EN 61439-1&3
Supply from bottom terminal
Dimensions and weight
Dimensions (H x D x W) mm 115 x 68.9 x 17.6
Weight g 200
Combination with auxiliary elements
Auxiliary contact yes
Signal contact / auxiliary switch yes
Shunt trip yes
Undervoltage release yes
Overvoltage release yes
Auxiliary contact for MCBs bottom fitting yes
2/14 4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2 C H C 4 2 0 0 0 1 C 0 2 0 2
2
—
eRCBOs
DSE201 M series 10000 A y type, B characteristic
2
—
eRCBOs
DSE201 M series 10000 A y type, C characteristic
—
eRCBOs
DSE201 M series 10000 AC w type, B characteristic
2
—
eRCBOs
DSE201 M series 10000 AC w type, C characteristic
—
Residual current relays
RD2
Technical features
Operating voltage [V] 230÷400 a.c. (RD2) and
4 8÷150 a.c./d.c. (RD2-4 8)
Frequency [Hz] 50÷60
Type A
Operating temperature [°C] -5…+4 0
Power consumption [W] <3.4, 230 V a.c.
RD2 Sensitivity settings I∆n [A] 0.03; 0.1; 0.3; 0.5; 1; 2
Tripping time settings [s] Fast (instantaneous); 0.3; 0.5; 1; 2; 5
Contact capacity [A] 10 at 250 V a.c. (ohmic)
Contact type NC-C-NO
Modules [No.] 2
Protection degree IP20
Standards IEC/EN 62020
2
—
Residual current relays
RD3
RD3P
RD3 residual current relays
The RD3 family of electronic residual current relays provides residual current protection
and monitoring functions according to IEC/EN 60947-2:2006 annex M when used in
conjunction with external toroids belonging to TR family, all S 200 miniature circuit
breakers and Tmax/XT range moulded case devices up to T5/XT4, for industrial installations.
The RD3 residual current relays can provide status indications through two output contacts.
—
Front panel residual current relays
ELR
2
—
Front panel residual current relays
ELR
—
Toroidal transformers
TR
Toroidal transformers
Technical features TRM TR1 TR2 TR3 TR4 TR4A TR160 TR160A TR5 TR5A TR6 TR6A
Core closed closed closed closed closed open closed open closed open closed open
Available [mm] 29 35 60 80 110 110 160 160 210 210 300 300
internal
diameter
Weight [kg] 0.17 0.22 0.28 0.45 0.52 0.6 1.35 1.6 1.45 1.85 2.1 2.3
Minimum [mA] 30 30 30 100 100 300 300 500 300 500 500 1000
TR measurable
current
Installation Any
position
Operating [°C] -10…+70
temperature
Storage [°C] -20…+80
temperature
Transformation 500/1
ratio
Dielectric test [kV] 2.5
voltage at
industrial freq.
for 1 min.
Max. insulating [V a.c.] 1000
voltage
Max. thermal [kA] 40/1 sec.
overload
Connections Screw terminal boards, max. section 2.5 mm2
Protection IP20
degree
—
Electrical installation solutions for buildings
3
Arc Fault Detection Devices
Index
AFDD S-ARC1 3/2
AFDD DS-ARC1 3/8
3/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
AFDD S-ARC1:
3
The S-ARC1 is the new 1P+N Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit
Breaker (MCB) in only two module width. Besides the overcurrent protection of the MCB, the S-ARC1
provides additional protection against series, parallel and earth arc faults. The series is perfectly in-
3
tegrated with ABB’s System pro M compact® range. Combined with a Residual Current Circuit
Breaker (RCCB) as upstream device, the S-ARC1 provides the best solution for complete protection
of electrical installations in buildings.
1/2 1/2 N N
1 ONI ON
1/2 1/2 N N
1 blink/sec S-ARC1S-ARC1
TEST AFDD
2/1 2/1 N N
1 ONI ON
1/2 1/2 N N
2 blink/sec S-ARC1S-ARC1
TEST AFDD
TEST TEST
Double slot terminals Compatibility with busbars All information on the device
Fail-safe terminals to avoid improper A quick and easy installation is possi- Main technical information are laser-
connection. Two slots of different di- ble in one step using a standard printed on the front and left side of
mensions (25 mm2 and 10 mm2) avail- ABB System pro M compact® busbar: product to ensure long readability.
able to allow the connection both with no additional cables required for the
cables and busbars. Connection possi- wiring.
ble both from top and bottom side.
Standard System pro M compact® clip
ensures a stable fixing on DIN rail and
easy and fast mounting and dismount-
ing operations.
3/4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
AFDD
Technical features and overall dimensions
3
S-ARC1 S-ARC1 M
Standards IEC/EN 62606; IEC/EN 60898-1
Electrical Number of poles 1P + N
Functions
Rated current In A 6 ≤ In ≤ 40
Rated voltage Ue V 230 – 240
Insulation voltage Ui V 500 V AC
Overvoltage category III
Pollution degree 2
—
AFDD
Technical features and overall dimensions
3
Installation
failsafe bi-directional cylinder-lift failsafe bi-directional cylinder-lift
Terminal type top / bottom
terminal (shock protected) terminal (shock protected)
Terminal size for cables top / bottom mm2 25/25 25/25
Terminal size for busbars top / bottom mm2 10/10 10/10
Tightening torque top / bottom Nm 2.8 2.8
Stripping length of the cable mm 12,5 12,5
on DIN rail EN 60715 (35mm) by on DIN rail EN 60715 (35mm) by
Mounting
means of mounting clip means of mounting clip
Mounting position Any Any
Supply from Top/Bottom terminals Top/Bottom terminals
Dimensions and weight
Dimensions (H x D x W) mm 85 x 69 x 35 mm 85 x 69 x 35 mm
Weight g 180 180
Combinable with accesso-
Auxiliary contact, signal contact/auxiliary switch, shunt trip, undervoltage release, overvoltage release
ries and auxiliaries
3/6 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
AFDD
S-ARC1, B and C characteristic
3
B-Characteristic
C-Characteristic
—
AFDD
S-ARC1 M, B and C characteristic
3
S-ARC1 M, B and C characteristics
Function: protection of end user single-phase circuits against short-circuit currents, over-
load, earth arc faults, parallel arc faults and series arc faults.
S-ARC1 M - B characteristics
S-ARC1 M - C characteristics
—
AFDD DS-ARC1:
3
The DS-ARC1 is the new 1P+N Arc Fault Detection Device (AFDD) with an integrated residual current
circuit breaker with overcurrent protection (RCBO) in only three module width.
The series offers a complete protection against arc faults and overvoltage, reducing the risk of fire.
3
The integrated RCBO is adding protection against overcurrent and earth fault currents:
compact solution for a complete protection of people and valuable assets.
1/2 1/2 N N
1 ONI ON
1/2 1/2 N N
1 blink/sec S-ARC1S-ARC1
TEST AFDD
2/1 2/1 N N
1 ONI ON
1/2 1/2 N N
2 blink/sec S-ARC1S-ARC1
TEST AFDD
TEST TEST
—
AFDD
DS-ARC1 arc fault detection device with integrated RCBO – technical data
3
DS-ARC1 DS-ARC1 M
Standards IEC/EN 62606; IEC/EN 61009-1; IEC/EN 61009-2-1
Electrical Type (wave form of the earth leakage sensed) A
Functions
Number of poles 1P + N
Rated current In A 6 ≤ In ≤ 20
Rated sensitivity I∆n A 0.03
Rated voltage Ue V 230 – 240
Insulation voltage Ui V 500 V AC
Overvoltage category III
Pollution degree 2
—
AFDD
DS-ARC1 and DS-ARC1 M
3
DS-ARC1, 6 kA, B and C characteristics
Function: protection of end user single-phase circuits against short-circuit currents,
overload, earth arc faults, parallel arc faults, series arc faults, earth faults currents.
—
Electrical installation solutions for buildings
Accessories for MCBs and RCDs
4
Index
Selection tables 4/2
Auxiliary elements for MCBs S200, SN 201,
RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch
disconnectors SD 200 series 4/13
Accessories for MCBs, RCDs,
AFDD and Switch Disconnectors 4/23
Motor operating and autoreclosing devices
for MCBs, RCDs and Switch Disconnectors 4/24
Busbars and accessories for MCBs,
RCDs and DS 200 series 4/28
Accessories for AFDD 1P+N,
S-ARC1 busbars 4/35
Busbar systems selection table 4/36
Accessories for MCBs and RCDs busbars 4/52
Auxiliary elements for S750 DR 4/62
Auxiliary elements and accessories
for MCBs S800 4/63
UNIFIX rapid wiring system 4/85
4/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
Combination of auxiliary elements with S200, S200M, S200P, DDA200 + S200 or DS200
(for S200 80-100A no combination with DDA)
2CDC092002F0212
In case of using rotary operating mechanism S2C-DH (only right side mountable) the auxiliary devices left side and bottom fitting auxiliary
contact could be used.
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
Combination of auxiliary elements with S200M, S200MUC
H, H
H-L
H-B
S/H
S/H
ST
ST-L
UR
OR
BP
NT
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
Combination of auxiliary elements with S200PR Combination of auxiliary elements with SU200M
and S200UDC, SU200PR
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
Combination of auxiliary elements with S200P
—
Auxiliary elements and accessories for MCBs and RCDs MOD-S
Selection tables
S 200
4
S ST-F/UR H H
MOD-S
ST MOD-S
IH
S/H S/H
(H)
ST Shunt trip for S 200 MCB S2C-A...
MOD-S* Motor operating device S2C-CM...
* in case of using S 200 coupled with DDA 200, MOD-S doesn’t
operate in case of earth-leakage fault MOD-S
** S 200 series MCBs and SD200 switch disconnectors up to 3P or
2P+ST can be coupled with MOD-S
H H
MOD-S
MOD-S
S200P**
ST MOD-S
* in case of using S 200 coupled with DDA 200, MOD-S doesn’t
operate in case of earth-leakage fault
** S200P MCBs in all poles variants can be coupled with MOD-S
DDA 200 4/7
SN 201
S/H S/H
— (H)
4
Combination of home automatic resetting unit Combination of auxiliary elements with F200
with F200
H H
H
or
S/H
ARH S/H
F 200 * (H)
H
ST-F H
F 200 or or
UR S/H
or
ARH Home automatic resetting unit F2C-ARH OR
AR/MOD-F S/H
* F 202 30 mA or 100 mA (depending on ARH model), max 63 A (H)
F2-CM4
F2-125A-B-S/H
Signal/Auxiliary contact
F2-CM4-MOD
4/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
DS203NC
S2C-S/H6R S2C-S/H6R (H)
F2 125 A S/H
F 204 125 A
SN201-IH S2C-S/H6R S2C-S/H6R (H)
S2C-H6R S2C-H6R
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
Combination of auxiliary elements with DS201, DS201 (2019), DS202C
J}t_
dx
x
tb%c
x_rv
_v dx
x
dx
bxc
—
Auxiliary elements and accessories for MCBs and RCDs
Selection tables
4
DSE201 M
H-R H-R
H H H
H-BF
S/H
S/H
(H)
ST-F H H
or UR
or OR
S/H
S/H
(H)
—
Auxiliary elements and accessories for AFDD
Selection tables
4
Combination of auxiliary elements Combination of auxiliary elements
with S-ARC1 and S-ARC1 M with DS-ARC1
S-ARC1 DS-ARC1
H H
S/H S/H
or H H-BF or H
S/H S/H
(H) (H)
ST-F ST-F
or UR or UR
or OR or OR
H H
S/H S/H
or H or H
S/H S/H
(H) (H)
—
Auxiliary elements and accessories for Switch Disconnectors SD 200
Selection tables
4
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Auxiliary contact and signal/auxiliary contact
S2C-S/H6R, S2C-H6R, S2C-H11L, S2C-H20L and S2C-H02L
AC14 1A/400V, 2A/230V - DC12 1A/220V, 1,5A/110V -
Utilization category
DC13 2A/60V, 4A/24V
Conventional free air thermal current A 10
Min. operational current/voltage* 10 mA at 12 V; 5 mA at 24 V
Rated conditional short-circuit
V 230 V AC 1,000 A with S201 K4
Auxiliary elements current
Overvoltage category III
Rated impuls withstand voltage
kV 4
(1.2/50µs)
0.75…2.5 (up to 2 x 1.5 mm2 for S2C-H11L, S2C-H20L and
Cross-section of conductors mm2
S2C-H02L)
Tightening torque Nm 1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L)
Contact stability in vibration test 5g, 20 sweep cycles 5…150…5 Hz at 24 V AC/DC, 5 mA
according to IEC/EN 60 068-2-6 automatic reclosing < 10 ms
Mechanical service life 10000 operations
Dimensions (H x D x W) mm 85 x 69 x 8.8
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Bottom-fitting auxiliary contact
S2C-H10 and S2C-H01
Conventional free air thermal current A 7.5
Bottom-fitting auxiliary contacts for S 200, S 200 M, S 200 P, S 200 S, SD 200, DS201 (2019),
DSE201 M, DS-ARC1
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Auxiliary contact / interface module for SN201 MCBs and DS203NC RCBOs
SN201-IH Function: indication of the device contact positions. The auxiliary contact can be used as
an interface module between SN201, DS203NC and other compact auxiliary elements.
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Shunt trip for S 200 MCBs
S2C-A1
Rated voltage AC V 12…60
DC V 12…60
Max release duration ms <10 @ Rated voltage
Min. release voltage AC V 8.4
DC V 8.4
S2C-A Power consumption Ub V 12 12 24 24 60 60
DC AC DC AC DC AC
Ib max A 2.2 2.5 4.5 5 14 8.8
Coil resistance Ω 3.7
Terminals Fale-safe bi-directional cylinder-lift-terminal
Tightening torque Nm 2.8
Dimensions (H x D x W) mm 85 x 69 x 17.5
S2C-A2
Rated voltage AC V 110…415
DC V 110…250
Max release duration ms <10 @ Rated voltage
Min. release voltage AC V 77
DC V 77
Power consumption Ub V 110 110 220 230 415
DC AC DC AC AC
Ib max A 0.4 0.5 1.1 1.0 2.7
Coil resistance Ω 225
Terminals Fale-safe bi-directional cylinder-lift-terminal
Tightening torque Nm 2.8
Dimensions (H x D x W) mm 85 x 69 x 17.5
Shunt trips
Function: remote opening of the device when a voltage is applied. Suitable for MCBs S 200
series, RCBOs DS 200 series, SD 200 switch disconnectors series.
Shunt trips use a coil like MCBs for tripping. To trip a shunt it is necessary to choose the
right voltage and make sure the corresponding Ibmax (as mentioned in the table above) is
provided by the power supply used. If the power supply can provide higher currents the
shunt trip will reduce the current to Ibmax due to its internal resistance.
As soon as the shunt tripped, the contact inside is open – the electrical circuit is discon-
nected even if the shunt trip is still powered on. The free-tripping mechanism of the shunt
trip allows a restart of the MCB only after the shunt trip gets no external release signal any-
more.
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Function: remote opening of the device when a voltage is applied. Suitable for RCCBs F 200
series and RCBOs DS201, DS201 (2019), DS202C, DSE201 M, AFDD S-ARC1.
It can be used with MCBs SN201 and RCBOs DS203NC series by means of SN201-IH interface
module.
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Undervoltage release
S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA
12 DC 24 AC 24 DC 48 AC 48 DC
Standards IEC/EN 60947-1
Rated voltage AC V 24 48
DC V 12 24 48
Frequency Hz 50…60
Release trip V 0.35 Un ≥ V ≥ 0.7 Un
S2C-UA
Terminals mm2 2x1.5
Consumption VA 2.2 3.6 2 3.6 2.1
Resistance to corrosion °C/RH constant atmosphere: 23/83 - 40/93 - 55/20; variable
atmosphere: 25/95 - 40/93
Protection degree IPXXB/IP2X
Tightening torque Nm 0.4
Dimensions (H x D x W) mm 85 x 69 x 17.5
S2C-UA S2C-UA S2C-UA S2C-UA S2C-UA
110 AC 110 DC 230 AC 230 DC 400 AC
Standards IEC/EN 60947-1
Rated voltage AC V 110 230 400
DC V 110 230
Frequency Hz 50…60
Release trip V 0.35 Un M V M 0.7 Un
Terminals mm2 2x1.5
Consumption VA 3.5 2.2 3.7 2.3 2.4
Resistance to corrosion °C/RH constant atmosphere: 23/83 - 40/93 - 55/20; variable
atmosphere: 25/95 - 40/93
Protection degree IPXXB/IP2X
Tightening torque Nm 0.4
Dimensions (H x D x W) mm 85 x 69 x 17.5
Undervoltage releases
Function: protection of the load in the event of a voltage drop (between 70% and 35% of its
rated value); positive safety (device’s tripping when the voltage is disconnected) emergency
stop by means of a button. Suitable for MCBs S 200 series, RCCBs F200 series and RCBOs
DS201, DS201 (2019), DS202C, DSE201 M, AFDD S-ARC1 series, DS 200 series, SD 200 switch
disconnectors series. It can be used with MCBs SN201 and RCBOs DS203NC series by means
of SN201-IH interface module.
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Overvoltage release
S2C - OVP2 S2C - OVP1
Rated voltage VAC 230
Rated frequency Hz 50
Max non-tripping voltage AC V 253
Max tripping voltage AC V 290 275
Tripping time @ 290V AC s t<1
S2C-OVP @ 380V AC s t<0.1
Peak current @ 315V AC A 1
@ 440V AC A 1.8
Max duration of impulse ms 7
command
Operating temperature °C -5….+40
Overvoltage release
Function: monitoring voltage between the neutral and phase; when an overvoltage reaches
the threshold value, the OVP device causes the tripping of the associated MCB or RCCB.
Suitable for MCBs of the S200 series up to 63 A, and RCCBs of the F200 series up to 100 A
and RCBOs DS201, DS201 (2019), DS202C, DSE201 M, AFDD S-ARC1 series, Suitable for SD
200 switch disconnectors series. It can be used with MCBs SN201 and RCBOs DS203NC se-
ries by means of SN201-IH interface module.
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Auxiliary contact and signal contact
S2C-H6R U, S2C-S6RU
Rating according UL 489 / 1A / 480 VAC
CSA22-2 No.5 2A / 277 VAC
1.5 A / 125 VDC
2A / 60 VDC
4 A / 24 VDC
Conventional free air thermal A 10
current
S 2C-H6R U
—
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200, DS201-DS202C, DS203NC,
DSE201 M, AFDD S-ARC1 and Switch disconnectors SD 200 series
4
Shunt trip
S2C-A1 U
Rated voltage AC V 12…60
DC V 12…60
Max release duration ms <10
Min. release voltage AC V 7
DC V 10
S 2C-A1 U Power consumption Ub V 12 12 24 24 60 60
DC AC DC AC DC AC
Ib max A 2.2 2.5 4.5 5 14 8.8
Coil resistance Ω 3.7
Terminals Fale-safe bi-directional cylinder-lift-terminal
Tightening torque Nm 2.8
Dimensions (H x D x W) mm 100 x 69 x 17.5
S2C-A2 U
Rated voltage AC V 110…415
DC V 110…250
Max release duration ms <10
Min. release voltage AC V 55
DC V 80
Power consumption Ub V 110 110 220 230 415
DC AC DC AC AC
Ib max A 0.4 0.5 1.1 1.0 2.7
Coil resistance Ω 225
Terminals Fale-safe bi-directional cylinder-lift-terminal
Tightening torque Nm 2.8
Dimensions (H x D x W) mm 100 x 69 x 17.5
—
Auxiliary elements for
MCBs, RCDs and Switch Disconnectors
4
IP20 Terminal cover
Description Bbn Order details Price Weight Pack
4016779 1 piece 1 piece unit
S 2C-BP
Plug-in base
Function: it is possible to transform a standard circuit-breaker of the S 200 and F 200 range
in a plug-in device which can be pulled out of the circuit where it is installed in one opera-
tion. Suitable for MCBs S 200 series and for RCCBs F 200 series up to 63 A and RCBOs DS201,
DS202C and AFDD S-ARC1 series.
S 2C-EST
4/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Motor operating and autoreclosing devices for
MCBs, RCDs and Switch Disconnectors
4
—
Motor operating and autoreclosing devices for
MCBs, RCDs and Switch Disconnectors
4
Motor operating devices
DS2C-CM
Supply V 12 ... 30 V a.c. +10% - 15% (50-60Hz); 12 ... 48 V d.c. +10% -
15%
Insulation voltage V 2500 for 1 minute
Power 12 V a.c. VA < 15
consumption 24 V a.c. VA < 22
during the
operation 30 V a.c. VA < 25
12 ... 48 V d.c. VA < 20
Power consumption at rest VA < 1.5
Remote control * by means of dry contacts
Make-time at ambient temperature sec <1
Opening time at ambient temperature sec < 0.5
Time before attempting to reclose the sec 8
motor operator
Number of operations < 20.000
Operating temperature °C - 25 ... + 55
Storage temperature °C - 40 ... + 70
Mounting on DIN rail EN 60715 by means of fast clip device
Protection degree (EN 60529) terminals: IP2X
enclosure: IP4X
Cables length of control circuit m < 1500
Cables cross-section mm 2
< 2.5
Signal contact (terminals 3 – 4 – 5) 1NO + 1NC (change-over contact)
Current carrying capacity 5 A (250 V AC) (resistive load)
Auxiliary contact (terminals 6 – 7 – 8) 1NO + 1NC (change-over contact)
Current carrying capacity 3 A (250 V AC) (resistive load)
Remote control terminals Terminal 9 = make contact; Terminal 10 = opening contact
Terminal 11 = common reference for control contacts, +5 V
d.c. (supplied by the motor operating device)
* Note: In case of the device opening due to a fault, please wait 8 seconds before attempting to reclose the motor operator.
—
Motor operating and autoreclosing devices for
MCBs, RCDs and Switch Disconnectors
4
Auto-reclosing unit
F2C-ARI F2C-ARI30
Supply V 12 ... 30 V a.c. +10% - 15% (50-60Hz); 12 ... 48 V d.c. +10% -
15%
Number of automatic reset attempts 3
Time of reset of the auto-reset meter sec 12 45
Power consumption 12 V a.c. VA < 15
during the operation 24 V a.c. VA < 22
30 V a.c. VA < 25
12...48 V d.c. VA < 20
Power consumption at rest VA < 1.5
F2C-ARI
Waiting time between auto-reset sec 3 30
attempts
Closing time at ambient temperature sec <1
Opening time at ambient sec < 0.5
temperature
Number of operations < 20.000
Operating temperature °C - 25 ... + 55
Cables length of control circuit m < 1500
Cables cross-section mm2 < 2.5
Signaling contact to signal a locked 1NA + 1NC (change-over contact)
state following three auto-reset
attempts (terminals 3–4–5)
Current carrying capacity 5 A (250 V AC) (ohmic load)
Auxiliary contact (terminals 6–7–8) 1NA + 1NC (change-over contact)
Current carrying capacity 3 A (250 V AC) (ohmic load)
Remote control By means of dry contacts
Remote control terminals Terminal 9 = closing and remote reset contact for locked
state; Terminal 10 = opening contact
Terminal 11 = common reference for control contacts, +5V
d.c. (supplied by the motor operating device)
Auto-reclosing units
Function: F2C-ARI and F2C-ARI30 allow the auto-reclosing of the coupled device in case of
unwanted tripping. Suitable for F 200 RCCBs up to 100 A.
—
Motor operating and autoreclosing devices for
MCBs, RCDs and Switch Disconnectors
4
Home automatic resetting unit
F2C-ARH /F2C-ARH-T
Power supply VAC 230
Number of automatic reclosing 1
attempts
Reset time for counter of automatic sec 12
F2C-ARH reclosing attempts
Power absorbed during the operation VA (t<0.5s) 20 max
Power consumption in stand-by W 0.4 max
Number of operations ≤ 10.000
Operating temperature °C -25 ... + 55
Signal contact cable section mm² ≤ 2.5
Signal contact for the locked state 1NA (change-over contact)
(terminals 1-2)
Signal contact rated current A 3 (250V AC)
Home automatic resetting unit with autotest (for domestic and similar applications)
Function: it recloses the associated residual current device, only after having checked that
there are no effective faults in the system protected by RCCB.
Suitable for 2-pole RCCB series with 30 mA or 100 mA sensitivities, max 63 A.
F2C-ARH-T allows the RCCB automatic test every six months.
—
Busbars and accessories for
MCBs S 200, RCDs F 200 and DS 200 series
4
➀ In case of feed in from the middle of the busbar it needs to be ensured, that the sum of junction currents per side must not exceed the max busbar current Is/phase.
Irrespective of the current carrying capacity (Is) of the busbar, the max. rated current of the devices terminal may not be exceeded.
4/29
—
Busbars and accessories for
MCBs S 200, RCDs F 200 and DS 200 series
4
Busbars PS…BP Busbars PS…BP-C Busbars PS..DC
MCB: SU200M, S200UDC, S200U, S200UP MCB: SU200M, S200UDC, S200U, MCBs, Fuseholders E90
S200UP
for IEC / UL applications for IEC / UL applications for IEC applications
IEC/EN 60947-1 IEC/EN 60947-1 IEC/EN 60947-1
UL489 UL508
UL489 UL 489 -
1P, 2P, 3P: 480 V AC 600 V AC/DC 690 V AC / 1000 V DC
10 kA in series with fuse NH3 355 A gG 500 V 10 kA 3 cycles @ 600 V / 140 kA Fuse 25 kA/0,1 s, 100 kA in series with fuse
Class J 200 A NH3 355 A gG
Feed on terminal of the device (supply side Feed on terminal of the device (supply Feed on terminal of the device (supply side optional) or
optional) or use of feeder terminals AST 35/15 side optional) or use of feeder terminal use of feeder terminal AST 35/18 DC or AST 35/45 DC
BP; SZ-ESK BP AST 35/58 BP-C
BSK BP BSK BP-C
AST 35/15 BP AST 35/58 BP-C AST 35/18 DC (for use with 1-phase busbar)
SZ-ESK BP AST 35/45 DC (for use with 2-phase busbar)
- PS-END 3 BP-C PS-END0, PS-END3
Feeder Terminals AST 35/15 BP Feeder Terminals AST 35/58 BP-C
and SZ-ESK BP
480 V AC 1000 V AC/DC
115 A ➀ 115 A use 75° wire
95 A use 60° wire
SZ-ESK BP 35 mm2 / 2AWG flexible AST 35/58 BP-C 28mm2 / 2AWG
with ferrules
50 mm2 / 1AWG solid / stranded
Cutting of busbar is not permitted. Shock protection only with mounted The copper bus has to be cut to a length that is app.
end caps ensured. For DC applications 10 mm less than the corresponding length of the plastic
the required increased clearence and busbar housing. Toch-safe only when used with the
creepage distances needs to be required end caps. Independant from the rated voltage
ensured. of the devices like busbars or feeder terminals the
creepage distances and distances over the air needs to
be considered. This is depending on the particular
application as well as on the complete assembling.
Feed in from the end of the busbar Feed in from the middle of the busbar
4/30 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Accessories for MCBs and RCDs
Busbars
4
PS 1/… PS 1/29/6
PS 1/.../16
PS 1/.../30
PS 3/… PS 1/38/6
(2CDL231 …)
PS 3/39 H PS 1/57/6 H
PS 3/39/16 H (integrierter
Hilfskontakt)
PS 1/38 H
PS 2/12
PS 1/38/16 H
PS 2/58
PS 2/58/16
PS 2/12 A
PS 2/58/16 A
PS 2/58 SP
PS 2/58/16 SP
PS 1/38 NT PS 2/48 H
PS 2/48/16 H
PS 2/48/16 HA
PS 2/48/16 SP
PS PS 3/46/16 H-IT
1/23/6
4/31
—
Accessories for MCBs and RCDs
Busbars
4
PS 3/12 PS 4/48/16
PS 3/12 A NH A
PS 3/12/16
PS 3/60
PS 3/60/16
PS 3/60/30
PS 3/60 A
PS 3/60/16 A
PS 3/60 SP
PS 3/60/16 SP
PS 3/48 H PS 4/58/ NN A
PS 3/48/16 H PS 4/58/16 NN A
PS 3/48/16 HA
PS 3/48/16 SP
PS 4/12
PS 4/12/16
PS 4/60
PS 4/60/16
PS 4/12 A
PS 4/60/16 A
PS 4/60/16 SP
PS 4/52/16 H
PS 4/52/16 HA
PS 4/52/16 SP
PS 4/12 NA
PS 4/58 N
PS 4/58/16 N
PS 4/58/16 NA
PS 4/58/16 N SP
4/32 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Accessories for MCBs and RCDs
Busbars
4
—
Accessories for MCBs and RCDs
Busbars
4
PS 2/12 DS 201 DS 201 … PS 2/48 H DS201 + S2C-S/H6R + DS201 ...
PS 2/12 A DS 202 C DC 202 C … PS 2/48/16 H DS202C + S2C-S/H6R + DS202C ...
PS 2/58 PS 2/48/16 HA
PS 2/58/16
PS 2/58/16 A
PS 1/12 A S 201 S 201 S 201 DS 201 … PS 4/48 NHA DS 201 + S2C-S/H6R + DS 201 …
PS 1/60 A DS 202 C … PS 4/48/16 NHA DS 202 + S2C-S/H6R + DS 202 …
PS 1/60/16 A
—
Accessories for MCBs and RCDs
Busbars
4
—
Accessories for AFDD 1P+N, S-ARC1
Busbars
4
PS 2/12 PS 2/48 H
PS 2/12 A F202 S-ARC1 … PS 2/48/16 H F202 + S2C-S/H6R + S-ARC1 …
PS 2/12/16 PS 2/48/16 HA
PS 2/58
PS 2/58/16 S2C- S2C- S2C-
PS 2/58/16 A F202 S-ARC1 S-ARC1 S-ARC1 F202 S/H6R S-ARC1 S/H6R S-ARC1 S/H6R
L1 L2 L3 L1 L2 L3
L1 L2 L3 N L1 N L2 N L3 N L1 N …
4/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Busbar systems
Selection table
4
PS / /
1 2 3 4 5 6 7 7
Phases
1 phase 1
2 phases 2
3 phases 3
4 phases 4
Number of pins
Diameter
10 mm2 - -
6 mm2 6 -
16 mm2 1 6
30 mm2 3 0
Application
Cross connection of RCCB and MCB (4th pin removed for RCCB 3+N) F I
Use of neutral conductor (phase sequence e.g. L1-N-L2-N-L3-N-L1...) N
Space for 1 side mounted auxiliary contact H
Space for 2 side mounted auxiliary contacts H 2
Pins for breaking off A
Cross connection of devices 3P+N + 1P+N (phase sequence L1-L2-L3-N-L1-N-L2-N-L1-N-...) N N
Busbars for IT networks I T
Busbars acc. to UL 489 (Branch Protection) B P
Busbars acc. to UL 1077 (Supplementary Protection) S P
*) only right side mounted auxiliary elements and bottom fixed auxiliary contacts can be considered for busbar connection
4/37
—
Busbar systems
Selection table
4
Pre-assembled busbars (not to be cut)
* phase sequence: L1, L2, L3, free, L2, L3, L1, ...
1-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END 0
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
38 1 10 0.27 586139 PS1/38H 2CDL210001R1038 0.27 30
38 1 16 0.45 586146 PS1/38/16H 2CDL210001R1638 0.45 30
—
Busbars and accessories for
MCBs S 200, RCDs F 200 and DS 200 series
4
1-phase busbars, connection of neutral (blue insulation), end caps END 1.1
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
28 1 10 0.24 629546 PS1/28N 2CDL210001R1028 0.14 50
28 1 16 0.32 629560 PS1/28/16N 2CDL210001R1628 0.20 50
57 1 10 0.24 579728 PS1/57NA ➁ 2CDL210011R1057 0.14 50
57 1 10 0.24 629539 PS1/57N 2CDL210001R1057 0.14 50
57 1 16 0.32 579735 PS1/57/16NA ➁ 2CDL210011R1657 0.20 50
57 1 16 0.32 629553 PS1/57/16N 2CDL210001R1657 0.20 50
1-phase busbars, connection of auxiliaries, end caps END 1.1 except PS 1/57/6
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
23 1 6 0.16 584739 PS1/23/6 2CDL210005R0623 0.09 50
29 1 6 0.14 580823 PS1/29/6 2CDL210005R0629 0.10 50
38 1 6 0.14 580816 PS1/38/6 2CDL210005R0638 0.09 50
57 1 6 0.11 585309 PS1/57/6 2CDL210005R0657 0.08 50
1-phase busbars, connection of hand operated neutral S2C-Nt (blue insulation),end caps END 1.1
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
38 1 10 0.410 655361 PS1/38 NT 2CDL210002R1038 10
2-phase busbars, connection of 2-pole devices with auxiliary, end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
48 2 10 0.47 556538 PS2/48H 2CDL220001R1048 0.35 10
48 2 16 0.68 556545 PS2/48/16H 2CDL220001R1648 0.48 10
48 2 16 0.68 584630 PS2/48/16HA ➁ 2CDL220012R1648 0.48 10
—
Busbars and accessories for
MCBs S 200, RCDs F 200 and DS 200 series
4
3-phase busbars, pin distance 17.6 mm, end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
11 3 10 0.10 649926 PS3/11 ➀ 2CDL230001R1011 0.08 50
12 3 10 0.09 576116 PS3/12 ➀ 2CDL230001R1012 0.09 50
12 3 10 0.09 584647 PS3/12A ➀➁ 2CDL230010R1012 0.09 50
12 3 16 0.16 562805 PS3/12/16 ➀ 2CDL230001R1612 0.12 50
60 3 10 0.51 514699 PS3/60 2CDL230001R1060 0.47 10
60 3 10 0.51 563758 PS3/60A ➁ 2CDL230010R1060 0.47 10
60 3 16 0.76 514705 PS3/60/16 2CDL230001R1660 0.65 10
60 3 16 0.76 563765 PS3/60/16A ➁ 2CDL230010R1660 0.65 10
60 3 30 2.65 654289 PS3/60/30 ➂➄ 2CDL230001R3060 2.65 10
3-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
39 3 10 0.51 556590 PS3/39H 2CDL230001R1039 0.43 10
39 3 16 0.76 556606 PS3/39/16H 2CDL230001R1639 0.60 10
3-phase busbars, connection of 2-pole devices (Phase+N) with auxiliary, end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
24 3 10 0.80 556576 PS3/24H 2CDL230001R1024 0.41 10
3-phase busbars, connection of 2-pole devices (Phase+Phase) with auxiliary, end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
46 3 16 0.98 662109 PS3/46/16H-IT 2CDL230006R1648 0.98 10
3-phase busbars, connection of 3-pole devices with auxiliary, end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
48 3 10 0.51 556613 PS3/48H 2CDL230001R1048 0.43 10
48 3 16 0.76 556644 PS3/48/16H 2CDL230001R1648 0.60 10
48 3 16 0.76 584654 PS3/48/16HA 2CDL230012R1648 0.60 10
➁
—
Busbars and accessories for
MCBs S200, RCDs F200, DS200 and AFDD
4
3-phase busbars, N of the RCD omitted, with auxilary at RCD end caps PS-END
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
12 3 10 0.11 571081 PS3/12FIH ➀ 2CDL230003R1012 0.09 50
—
Busbars and accessories for
MCBs S200, RCDs F200, DS200 and AFDD
4
4-phase busbars, connection of 4-pole devices with auxiliary, end caps PS-END 1
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
52 4 16 1.30 656115 PS4/52/16H 2CDL240101R1652 0.78 10
52 4 16 1.30 656122 PS4/52/16HA 2CDL240212R1652 0.78 10
➁
4-phase busbars, connection of 1+N or RCBOs with auxiliary, end caps PS-END 1
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
48 4 16 1.48 656160 PS4/48/16NHA 2CDL240114R1648 0.76 10
➁
4-phase busbars, connection of 4-pole RCD with 1+N , end caps PS-END 1
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
58 4 10 0.80 656177 PS4/58NNA ➁ 2CDL240110R1058 0.58 10
58 4 16 1.21 656184 PS4/58/16NNA 2CDL240110R1658 0.80 10
➁
—
Busbars and accessories for
RCD-blocks DDA 200
4
Busbars (suitable for cutting) for DDA 200 and DS 200 – bottom mounting (RCD)
3-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 3
(phase sequence L1-L2-free-free-L3-L1.....without N)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
3-phase busbars, connection of DDA 202 and DS 202 with auxiliary, end caps PSB-END 3
(phase sequence L1-L2-aux.(free)-free-free-L3-L1-aux.(free).....without N)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
4-phase busbars, connection of DDA 204 63 A and DS 204 50 A and 63 A, end caps PSB-END 4
(phase sequence L1-L2-L3-N-free-free-free-free-L1.....)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
Busbars (suitable for cutting) for DDA 200 and DS 200 – top side mounting (MCB)
2-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 3
(phase sequence L1-L2/N-free-free-.....)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
3-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 3
(phase sequence L1-L2-free-free-L3-L1.....without N)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
3-phase busbars, connection of DDA 202 and DS 202 with auxiliary, end caps PSB-END 3
(phase sequence L1-L2-aux.(free)-free-free-L3-L1-aux.(free).....without N)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
—
Busbars and accessories for
RCD-blocks DDA 200
4
4-phase busbars, connection of DDA 202 and DS 202, end caps PSB-END 4
(phase sequence L1-N-free-free-L2-N...)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
4-phase busbars, connection of DDA 202 and DS 202 with auxiliary, end caps PSB-END 4
(phase sequence L1-N-aux.(free)-free-free-L2-N-aux.(free)...)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
4-phase busbars, connection of DDA 204 25 A and 40 A and DS 204 up to 40 A, end caps PSB-END 4
(phase sequence L1-L2-L3-N-free-free-L1.....)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
4-phase busbars, connection of DDA 204 25 A and 40 A and DS 204 up to 40 A with auxiliary, end caps PSB-
END 4 (phase sequence L1-L2-L3-N-aux.(free)-free-free-free-free-L1)
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
—
Busbars and accessories for
AFDD S-ARC1 and DS-ARC1
4
No. of pins Phases mm² Cu-No Bbn Ordering details Ordering details Weight Pkg qty
40 16779 1 pcs pce
kg EAN Type code Order code kg
2-phase busbars, connection of 2-pole devices with auxiliary, end caps PS-END
48 2 10 0.470 556538 PS2/48H 2CDL220001R1048 0.354 10,000
48 2 16 0.680 556545 PS2/48/16H 2CDL220001R1648 0.580 10,000
4-phase busbars, connection of 4-pole F204 with 1+N S-ARC1, end caps PS-END 1, Bottom side installation
12 4 10 0.105 060301 PS4/12NN 1) 2CDL240102R1012 0.110 30
12 4 16 0.149 060332 PS4/12/16NN 1) 2CDL240102R1612 0.145 30
58 4 10 0.803 656177 PS4/58NNA 2CDL240110R1058 0.568 10
58 4 16 1.205 656184 PS4/58/16NNA 2CDL240110R1658 0.774 10
4-phase busbars, connection of 4-pole F204 with 1+N S-ARC1, end caps PS-END 1, Top side installation
12 4 10 0.105 060356 PS4/12NNT 1) 2CDL240103R1012 0.110 30
12 4 16 0.149 060370 PS4/12/16NNT 1) 2CDL240103R1612 0.145 30
No. of pins Phases mm² Cu-No Bbn Ordering details Ordering details Weight Pkg qty
40 16779 1 pcs pce
kg EAN Type code Order code kg
2-phase busbar, end caps PS-END; both top and bottom side mounting
8 2 16 0.105 063104 PS 2/8/16 AFDD 2CDL220102R1608 0.095 50
40 2 16 0.495 063111 PS 2/40/16 AFDD 2CDL220102R1640 0.51 10
4-phase busbar, end caps PS-END 1; first one: top side mounting; second one: bottom side mounting
36 4 16 0.985 063128 PS 4/36/16 AFDD T 2CDL240103R1636 0.67 10
36 4 16 0.985 063135 PS 4/36/16 AFDD 2CDL240102R1636 0.67 10
4-phase busbar, connection with auxiliary, end caps PS-END 1; first one: top side mounting; second one: bottom side mounting
30 4 16 0.915 063142 PS 4/30/16 H AFDD T 2CDL240103R1630 0.62 10
30 4 16 0.915 063159 PS 4/30/16 H AFDD 2CDL240102R1630 0.62 10
End caps PS-END and PS-END 1 for S-ARC1 and DS-ARC1 busbars
—
Busbars and accessories
Accessories for busbars PS...
4
Accessories for busbars PS ...
End caps
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
➀ bbn-No. 4012233
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
SZ-BSK pins 4016779 1 1 piece unit
* closed version
—
Busbars and accessories for
MCBs SN 201 and F200/S200 + SN 201
4
No. pins Phases Cross Bbn Order details Price Weight Pack
section 8012542 1 1 piece unit
Terminals, insulated
End caps
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
064251 BS9-END 3P a 2CSL980001R0001 0.001 20
—
Busbars and accessories for
MCBs acc. UL 489: SU200 M, S200 UDC, S200 U and S200 UP
4
Pre-assembled busbars (not to be cut) acc. to UL 489, suitable for SU200 M, S200 UDC,
S200 U and S200 UP
Technical features
Feeder terminals SZ-ESK BP, AST 35/15 BP
Max. operating voltage 480 V AC
Max. current 80 A (115 A for cubicle size ≥ 30" x 30" x 10") ➀
Protection degree IP 20
➀ inclusive of end caps
➁ pre-cutted pins Wire range SZ-ESK PB: 35 mm2 / 2AWG flexible with ferrule
➂ use end cap PS-END 3 50 mm2 / 1AWG solid/stranded
➃ use end cap PS-END 3.1
AST 35/15 BP: 25 mm2 / 3AWG flexible with ferrule
➄ removal of installed MCB not possible
35 mm2 / 2AWG solid/stranded
➀ regardless of the rated current of the feeder terminal the maximum current rating of the device terminal may not be exceeded
4/48 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Busbars and accessories for
MCBs acc. UL 489: SU200 M, S200 UDC, S200 U and S200 UP
4
Busbars PS….BP-C (suitable for cutting) for MCBs acc. to UL489: SU200 M, S200 UDC,
S200 U and S200 UP
1-phase busbars, pin distance 17.6 mm, end caps PS-END 3 BP-C
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
57 1 25 0.47 949910 PS1/57/25BP-C 2CDL210489R5725 0.775 10
1-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END 3 BP-C
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
37 1 25 0.5 949934 PS1/37/25HBP-C 2CDL210489R3725 0.661 10
2-phase busbars, pin distance 17.6 mm, end caps PS-END 3 BP-C
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
56 2 25 0.888 949941 PS2/56/25BP-C 2CDL220489R5625 0.969 10
2-phase busbars, connection of 2-pole devices with auxiliary, end caps PS-END 3 BP-C
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
46 2 25 0.87 949958 PS2/46/25HBP-C 2CDL220489R4625 0.943 10
3-phase busbars, pin distance 17.6 mm, end caps PS-END 3 BP-C
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
57 3 25 1,31 949965 PS3/57/25BP-C 2CDL230489R5725 1.198 10
3-phase busbars, connection of 3-pole devices with auxiliary, end caps PS-END 3 BP-C
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
piece
kg EAN Type code Order code kg pc.
48 3 25 1,28 949972 PS3/48/25HBP-C 2CDL230489R4825 1.129 10
39 3 25 1,305 949989 PS3/39/25HBP-C 2CDL230489R3925 1.115 10
—
Busbars and accessories for
MCBs acc. UL 1077: S200, S200 M, S200 P, S200 MUC, S200 MTUC,
ST200 M and Fuse Disconnectors E90
4
Busbars suitable for cutting
No. of pins Phases mm² EAN Type code Order code kg pc.
1-phase busbars, pin distance 17.6 mm, end caps PS-END 1 CB
57 1 18 906760 PS 1/57/18 CB 2CDL210508R5718 0.289 10
57 1 25 906913 PS 1/57/25 CB 2CDL210508R5725 0.360 10
1-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END 1 CB
37 1 18 906784 PS 1/37/18 H CB 2CDL210508R3718 0.254 10
37 1 25 906937 PS 1/37/25 H CB 2CDL210508R3725 0.310 10
2-phase busbars, pin distance 17.6 mm, end caps PS-END 3 CB
56 2 18 906807 PS 2/56/18 CB 2CDL220508R5618 0.639 10
56 2 25 906951 PS 2/56/25 CB 2CDL220508R5625 0.795 10
2-phase busbars, connection of 2-pole devices with auxiliary, end caps PS-END 3 CB
46 2 18 906821 PS 2/46/18 H CB 2CDL220508R4618 0.672 10
46 2 25 906975 PS 2/46/25 H CB 2CDL220508R4625 0.782 10
3-phase busbars, pin distance 17.6 mm, end caps PS-END 3
57 3 18 906852 PS 3/57/18 CB 2CDL230508R5718 0.929 10
57 3 25 906999 PS 3/57/25 CB 2CDL230508R5725 1.026 10
3-phase busbars, connection of 3-pole devices with auxiliary, end caps PS-END 3 CB
48 3 18 906876 PS 3/48/18 H CB 2CDL230508R4818 0.788 10
48 3 25 907019 PS 3/48/25 H CB 2CDL230508R4825 0.974 10
3-phase busbars, connection of 1-pole devices with auxiliary, end caps PS-END 3 CB
39 3 18 906890 PS 3/39/18 H CB 2CDL230508R3918 0.794 10
39 3 25 907033 PS 3/39/25 H CB 2CDL230508R3925 0.974 10
Accessories
Single-pole terminal, can be mounted side by side, feed to the busbar pin
710381 SZ ESK SP 2CDL200111R5001 0.032 50
End caps
for use with PS 1…CB 907057 PS-END 1 CB 2CDL200508R0001 0.001 50
for use with PS 2…CB and PS3…CB 907071 PS-END 3 CB 2CDL200508R0003 0.002 50
4/50 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Busbars and accessories for
MCBs acc. UL 1077: S200, S200 M, S200 P, S200 MUC, S200 MTUC,
ST200 M and Fuse Disconnectors E90
4
—
Busbars and accessories for
MCBs and Fuseholder E90, for use in applications up to 1 000 V DC
4
Busbars PS…DC (cuttable) for use with end caps PS-END0 and PS-END3
Accessories
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Rail connectors
For wiring of component rails in the consumer unit, rail-to-rail clearance 125 mm. In the case
of the 4 -pole connector, the color of the N conductor is blue.
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
No. of Phases mm2 Cu-No. Bbn Order details Price Weight Pack
pins 4016779 1 1 piece unit
Labelling system
Package comes with 40 labels, marked or blank. Blank labels can be labeled by hand with an
indelible, waterproof pen or using a computerised labelling system (plotter).
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Identification system ILS
The ILS individual identification sytem for labels is a DIN A5 polyester film for ink jet and
laser printers with high temperature resistance. (If laser printers are used, please check
whether self-adhesive film with thickness of 250 µm can be fed.) Adhesive coating
3MTM9471 LE has obtained UL approval (file No. MH 11410). There are two types of sheet: un-
cut for making individual labels or precut with 23 stripes (6 x 191 mm each) for labelling 11
BS 1/10
devices (1-module width) per stripe. Word template can be downloaded from www.abb.de/
stotz-kontakt. Can also be used as write-on labels (ink, ballpoint pen, pencil, marker).
Conn. Terminal Type of Cu- Bbn Order details Price Weight Pack
capac- Iug connec- No. 4016779 1 1 piece unit
ity tion piece
Ast 25/15 S LxW mm kg EAN kg pc.
Ast 50/15 S mm2 Type code Order code
Ast 50/15 6-25 15/4 90° 0.012 656535 Ast 25/15 QS 2CDL200010R2515 50
Ast 50/18 6-25 15/4 straight 0.012 656542 Ast 25/15 S 2CDL200011R2515 50
6-25 15/6 90° 0.012 656474 Ast 25/15 Q 2CDL200000R2515 50
6-25 22/4 90° 0.012 669436 Ast 25/22 QS 2CDL200010R2522 50
6-25 30/4 90° 0.012 656481 Ast 25/30 QS 2CDL200010R2530 50
6-25 30/6 90° 0.014 656498 Ast 25/30 Q 2CDL200000R2530 50
6-50 15/4 90° 0.014 656504 Ast 50/15 QS 2CDL200000R5015 50
Ast 50/32 Q
6-50 15/4 straight 0.014 656566 Ast 50/15 S 2CDL200011R5015 50
6-50 15/7 90° 0.014 656559 Ast 50/15 Q 2CDL200010R5015 50
6-50 15/7 straight 0.014 656511 Ast 50/15 2CDL200001R5015 50
5-50 17.5/7 90° 0.019 656580 Ast 50/18 Q 2CDL200100R5018 50
6-50 17.5/7 straight 0.019 656573 Ast 50/18 2CDL200101R5018 50
6-50 32/6 90° 0.017 656528 Ast 50/32 Q 2CDL200000R5032 50
25-95 21/6.5 straight 0.06 522618 SZ-Ast 95 gk* GHV0360501R0012 0.067 50
25-95 21/6.5 straight 0.06 522625 SZ-Ast 95* GHV0360501R0013 0.067 50
Abbreviations: Q terminal 90° * not for pro M compact S narrow connection pin
4/54 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Feeder terminals
Single-pole terminals can be mounted side by side with multipole terminals.
Conn. Termi- Type Cu-No. Bbn Order details Price Weight Pack
SZ-ESK 2
capac- nal Iug of con- 4016779 1 1 piece unit
ity nec- piece
LxW tion kg EAN kg pc.
mm2 mm Type code Order code
6-35 646765 SZ-ESK 2 2CDL200001R3501 0.024 10
6-50 652575 SZ-ESK 3 2CDL200003R5001 0.025 10
6-50 652889 SZ-ESK 3 S 2CDL200003R5003 0.024 10
SZ-ESK 3
SZ-DB 121 10 135 0.010 55670 0 SZ-DB 122 N GHV0361425R0031 0.02 500/25
6 260 0.014 55680 9 SZ-DB 231 N GHV0361425R0032 0.02 500/25
10 0.022 55690 8 SZ-DB 232 N GHV0361425R0033 0.04 250/25
SZ-DB 232 N
10 330 0.029 55700 4 SZ-DB 311 GHV0361425R0034 0.05 100/25
SZ-DB 125 N
with fork-type cable lug and ultrasonic compacted cable ends (black)
Conn. Lenght Bbn Order details Price Weight Pack
capacity 4012233 1 1 piece unit
piece
mm2 EAN Type code Order code kg pc.
6 125 0.007 55660 1 SZ-DB 123 GHV0361425R0006 0.01 1000/50
10 135 0.012 55710 3 SZ-DB 124 N GHV0361425R0035 0.02 500/25
6 260 0.014 55720 2 SZ-DB 235 GHV0361425R0036 0.02 500/25
10 0.024 55730 1 SZ-DB 236 GHV0361425R0037 0.04 250/25
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Neutral and protective-conductor terminals with insulation holder for quick fastening
onto DIN rails EN 50 022
SZ-6/3
Input Output Bbn Order details Price Weight Pack
4012233 1 1 piece unit
Neutral and protective-conductor terminals with insulation holder for quick fastening
onto DIN rails EN 50 022
Neutral with blue insulation holder; type C finger safe, conductor opening closed on one side
Input Output Bbn Order details Price Weight Pack
4012233 1 1 piece unit
SZ-Ktr with KLB mm2 mm2 EAN Type code Order code piece kg pc.
1 x 16 6 x 16 55570 3 SZ-N 6/3 GHV0360876R0001 0.027 20
1 x 16 11 x 16 55580 2 SZ-N 11/3 GHV0360876R0002 0.043 20
1 x 16 6 x 16 57095 4 ➀ SZ-N 6/3 C GHV0360876R0011 0.028 20
1 x 16 6 x 16 57096 1 ➀ SZ-N 11/3 C GHV0360876R0012 0.046 20
Protective conductor with green/yellow insulation holder; type C finger safe, conductor
opening closed on one side
Conn. Lenght Bbn Order details Price Weight Pack
SZ-N6/3 capacity 4012233 1 1 piece unit
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Blanking plates
For device covers with materials of a thickness of 1 to 3 mm, width: 1 module = 17.5 mm;
color: grey RAL 7035, white RAL 9001
SZ-BP 1
Input Output Bbn Order details Price Weight Pack
4012233 1 1 piece unit
Sealing plate
Seal-proof locking of stamped-out device covers.
Detachable only from the inside of the device cover.
Can be used for device covers with 1.5 to 3 mm material thickness.
SZ-BP R
Height of Width Bbn Order details Price Weight Pack
cutout/color 4012233 1 1 piece unit
piece
mm mm EAN Type code Order code kg pc.
46/grey 1500 60290 2 SZ-VP 1500 GJI9959038R0001 0.366 10
End bracket
Prevents lateral shifting of built-in devices mounted on DIN rails according to DIN EN 60 715,
SZ-VP 1500
35 x 7.5 mm.
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
59090 2 END GJI1001814R0001 0.02 50
Filling piece
END
e.g. for heat dissipation of closely mounted devices that generate much heat. Width 8.75
mm, as spacer, two different heights, breakable, for DIN rails according to DIN EN 60 715, 35
x 7.5 mm.
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
8.75 06070 2 SZ-FST 2 GHL5301908R0002 0.01 25
SZ-FDT 2
Spring piece
Holder for device covers, various heights available (in connection with FST 2 filling piece)
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
06080 1 SZ-FDT 2 GHL5301908R0005 0.002 25
4/57
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Filling piece
Two different heights, breakable, for DIN rails according to DIN EN 60 715, 35 x 7.5 mm
for MCBs S 220 (3 different heights)
bbn-Nr. 4016779
Spring catch for mounting devices onto DIN rails (DIN EN 60 715, 35 x 7.5)
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
for screw type M4 64560 2 SZ-FB 45.53-3 GJI1842013P0003 0.03 50
for screw type M5 64580 0 SZ-FB 45.53-1 GJI1842013P0004 0.03 50
SZ-FST
False poles
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
False pole - 1 module 061304 FP1 16021765 0.01 100
SZ-FB 45.53-1
False pole - 2 modules 061403 FP2 16021773 0.014 50
False pole - 4 modules 061502 FP4 16021781 0.022 30
SZ-FB 45.53-3 False pole - 6 modules 061601 FP6 16021799 0.031 20
Support for false pole 061700 SFP 16021831 0.012 10
FP
4/58 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
DIN rails
DSW 6 DIN rails (DIN EN 60 715 – 35 x 7.5) for individual installation with 2 screws on an even surface
DSW 4 (1 module = 17.5 mm)
DIN rail DIN EN 60 715, 35 x 7.5, material thickness 1 mm, surface protected, galvanised.
SKV-GTS 1
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
241 04090 2 SKV-GTS 1 GHL1101915R0001 0.09 40
DIN rails DIN EN 60 715, 35 x 7.5, material thickness 1 mm, surface galvanised.
SZ-SI 45.460
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
1000 59730 7 SZ-SI 45.460 GJI2322218R0001 0.35 10
2000 59760 4 SZ-TS 7.5 L2 GJI2322218R0007 0.70 20
SZ-TS 7.5 L2 DIN rails DIN EN 60 715, 35 x 15, material thickness 1.5 mm, surface galvanised
Bbn Order details Price Weight Pack
4012233 1 1 piece unit
piece
EAN Type code Order code kg pc.
2000 59780 2 SZ-SI 45.472 GJI2322218R0010 1.30 10
2000 59770 3 SZ-TS 15 L2 GJI2322218R0009 0.78 10
SZ-SI 45.472
SZ-TS 15 L2
4/59
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Rotary operating mechanism (usable just with S200 devices)
For the actuation of 2-, 3- or 4pole miniature circuit-breakers in closed distribution boards
for driveaxles of 5 or 6 mm2 (square)
Handles
Handle IP 65, 65 x 65 mm, padlockable with max. 3 padlocks (bail diameter 5 - 8 mm),
door interlock in ON-position, adjustable*
Handle IP 65, 65 x 65 mm, padlockable with max. 3 padlocks (bail diameter 5 - 8 mm),
door interlock in ON-position
OXS6X
* OH_2_J enables selection of MCB behavior when opening panel door (remain switched on or switch off).
OH_2_J1 will cause MCB to switch off when opening panel door.
Axle extension
Type and order numbers are for one piece. For selector type handles. Shaft diameter 6 mm.
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Elevation piece
Compensates for different size of built-in devices with a mounting height of 68 mm and
power MCBs of series S500 (83 mm)
Terminal cover KA 27
KA 27 H + KA 27 S Provides overall touch protection of live parts. Suitable for installations acc. to DIN EN 50274
(DIN VDE 0660 Part 514) and BGV A2.
End parts can be snapped onto mounting rails EN 60 715, 35 mm. Covers are 486 mm = 27
modules (18 mm each) long. Knockouts for each half module for individualised use.
—
Accessories
for S 200, SN 201, F 200, DS 200 and other series
4
Flanges
—
Auxiliary elements for
S750 DR series
4
S750DR-AUX
Electrical data
Standards DIN EN 62019 (VDE 0640), IEC/EN 62019
DIN EN 60947-5-1 (VDE 0660-200), IEC/EN 60947-5-1
Conventional free air thermal 6 A
current Ith
Utilisation categories AC14 AC15 DC12 DC13
Ue 400 V 230 V 400 V 230 V 250 V 125 V 60 V 24 V
Ie (max) 2A 6A 2A 6A 0.5 A 1.5 A 2A 4A
Rated insulation voltage U 690 V AC
acc. to IEC/EN 60664-1
Overvoltage category IV
Pollution Degree 3
Protection degree acc. to IP20
IEC/EN 60529
Min. switching power DC 5V DC/5 mA, 12V DC/5 mA
Rated impuls withstand 6 kV
voltage Uimp (1.2/50 μs)
Installation
Cross-section 1 conductor 0.75 - 2.5 mm² solid, flexibel with and without insulated ferrule conductors
of 2 conductor 2 x 0.75 - 2 x 2.5 mm² solid, flexibel with and without insulated ferrule
Tightening torque 0.8 Nm
Mechanical data
Vibration resistance 5 g, 20 cycles at 5 ...150...5 Hz with 24 V AC/DC, 5 mA, without switching
according to IEC/ operation
EN 60 068-2-6
Mechanical endurance 10,000 ops.
Pole dimensions (H x D x W) 128 x 77 x 8.7
Mounting
Only 1 auxiliary contact mountable on the right site
Not mountable to S751DR/3
—
Auxiliary elements for MCBs S800 series
Selection table
4
Combination between auxiliary elements
and S800
S800 S800U-PLL
2CCC413057Z0002
S800-RD
S800-RHE-S
S800-IP9
S800-PLL
S800-RHE
I
0
—
Auxiliary elements for S800
S800-AUX
4
S800-AUX
Auxiliary contact for external display
The S800-AUX auxiliary contact is for electrical display of the operating state of the high
performance MCB. Both changeover contacts always switch simultaneously with the live
conductor contact and detect the following operating states:
• Manual tripping
• Tripping due to thermal overload
• Tripping due to magnetic overload (short-circuit)
—
Auxiliary elements for S800
S800-AUX/ALT
4
S800-AUX/ALT
Combined auxiliary and signal contact for the external display
The S800-AUX/ALT combined auxiliary and signal contact is used for electrical signaling of
the operating state of the high performance MCB.
The AUX auxiliary contact always switches simultaneously with the live conductor contact
and detect the following forms of tripping:
• Manual switch on/off
• Tripping due to thermal overload
• Tripping due to magnetic overload (short-circuit)
• Tripping by S800-SOR or S800-UVR
The ALT signal contact detects the following forms of tripping of the high performance MCB:
• Tripping due to thermal overload
• Tripping due to magnetic overload (short-circuit)
• Tripping by S800-SOR or S800-UVR
—
Auxiliary elements for S800
S800-AUX/ALT
4
Technical data
—
Auxiliary elements for S800
S800-NT
4
S800-NT
Disconnectable neutral conductor 63 A
The S800 high performance MCB is force-opened before actuating the
disconnectable neutral conductor S800-NT.
—
Auxiliary elements for S800
S800-RSU system
4
Mounting ability
The S800-RSU is mountable on any multipole S800 High Performance MCB. Wiring and
operation is feasible on field. The connection has to be done by a 10-pole Micro Fit 3.0
(not included in delivery). S800-RSU operated with standard MDRC pushbuttons and indica-
tor lights or can be done via programmable logic controllers (PLCs).
Switching times
OFF –> ON <<500 ms
from signal to contact closing
Safety Intelligence
• When detecting manual use, inputs are deactivated for 10 seconds
• If the spindle is rotated more than 360°, all outputs become active
• Manual switch off via lever is possible (S803, S804)
• Manual switch on via lever is not possible (S802)
• RSU is locked for five minutes after three switching attempts leading to a trip
• Mechanical fixation via lock slider blocking the spindle
S800-RSU-CP
S800-RSU cable incl. 10-pole Micro Fit 3.0 plug
Length of cable: 3m
Cross section: 10 x 0.5 m2
Temperature range
moving state: –5 ºC ... +70 ºC
fixed state: –30 ºC ... +80 ºC
Rated voltage: 300 V
Conductor resistance: 39.0 Ω/km
Approvals: S+, UL
4/69
—
Auxiliary elements for S800
S800-RSU system
4
Technical data
—
Auxiliary elements for S800
S800-SOR
4
S800-SOR
Shunt opening release
The S800-SOR shunt opening release is for remote release of the S800- high performance
MCB using an electrical impulse. Operation of the trigger is guaranteed at a voltage between
70 % and 110 % of the rated mains voltage Un both for AC and DC.
Shunt operation release EAN Type code Order code piece kg pc.
12 VAC/DC 1212070 S800-SOR12 2CCS800900R0201 0,15 1
24 VAC/DC 1208318 S800-SOR24 2CCS800900R0191 0.15 1
48...130 VAC/DC 1208349 S800-SOR130 2CCS800900R0221 0.15 1
110...250 VAC/DC 1208332 S800-SOR250 2CCS800900R0211 0.15 1
220...400 VAC/DC 1208356 S800-SOR400 2CCS800900R0231 0.15 1
4/71
—
Auxiliary elements for S800
S800-UVR
4
S800-UVR
Undervoltage release
The S800-UVR undervoltage release can be used as an emergency-stop cut-as by use of
suitable emergency stop buttons. The undervoltage release switches the power supply to
the high performance MCB off in case of a failure or if the value falls below 0.7 x Un. After
tripping, the high performance MCB can be switched back on as soon as the voltage is over
0.85 x Un.
—
Auxiliary elements for S800
S800-SCL
4
S803S-SCL
Short-circuit current limiter
The S803S used together with an S803S-SCL ensures reliable switch-off of short-circuit
currents up to 100 kA, at an operating voltage of 440 V AC and over the entire rated current
range of up to 125 A.
For applications at 690 V AC, the combination of S803S-SCL ensures reliable short-circuit
protection up to 50 kA; here also, this is ensured over the entire rated current range up to
125 A, typical for the S800.
—
Auxiliary elements for S800
S800-SCL
4
GTIN Order details Price Weight Pack
Short-circuit current limiter 7612271 1 1 piece unit
with interchangeable
cage terminal [A] EAN Type code Order code piece kg pc.
32 1208912 S803S-SCL32 2CCS800900R0291 0.74 1
63 1208929 S803S-SCL63 2CCS800900R0301 0.74 1
125 1208905 S803S-SCL125 2CCS800900R0281 0.74 1
—
Auxiliary elements for S800
S800-SCL-SR
4
S800-SCL-SR
Self-resetting short-circuit limiter
The S800-SCL-SR can be used together with S800S High Performance MCB or Manual
Motor Starters. It limits the short-circuit current until the downstream means of protection
trips. Its current continuity makes it as the ideal solution for group protection. All parallel
branches remain operative.
S800-SCL-SR is available at rated voltages 400/690 Vac and 580/100 Vac acc.to the type.
—
Auxiliary elements for S800
S800-SCL-SR
4
S803HV-SCL-SR in combination with S803HV-K
General data
Standard IEC 60947-2
Poles 3
Rated frequency f Hz 50/60
Data acc. to IEC 60947-2
Rated operational voltage Ue V AC 580/1000
Rated operational current In A 32, 63, 100
Rated ultimate short-circuit breaking capacity Icu kA 15
Rated service short-circuit capacity Ics kA 10
Rated insulation voltage Ui V AC 1000
Rated impulse withstand voltage Uimp kV 8
Mechanical data
Housing Material group I, RAL 7035
Toggle black, lockable
Protection degree acc. to IEC / EN 60529 IP20; IP40 (actuating side only)
Classification acc. to NF F16-101, NF F 16-102 I3, F2
Classification acc. to IEC 61373 Cat. 1, Class B
(shock and vibration)
Shock resistance acc. to IEC / EN 60068-2-27 Test Ea: 5 g / 30 ms
Vibration resistance acc. to IEC / EN 60068-2-6 Test Fc:
2–13.2 Hz / 1 mm
13.2–100 Hz / 0.7 g
with load 100 % x Ie
Environmental conditions (damp heat) 12+12 cycle with 55 °C / 90 - 96 % RH
acc. to IEC / EN 60068-2-30 and 25 °C / 95 - 100 % RH
Environmental conditions (dry heat) 16 hours 55 °C / 2 hours 70 °C / 55 % RH
acc. to IEC / EN 60068-2-2
Ambient temperature °C -25 … +60
Storage temperature °C -40 … +70
Installation
Terminal Failsafe cage terminal
Connection (top/bottom) – Cu only mm2 1 … 50 solid / stranded
1 … 70 flexible
Tightening torque Nm 3.5
Screwdriver POZI 2
Mounting EN 60715
Mounting position any
Supply side any
Dimension and weight
Pole dimension (H x L x W) mm 142 x 76.5 x 26.5
Pole weight kg 0.25
4/76 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Auxiliary elements for S800
S800-SCL-SR
4
—
Auxiliary elements for S800
S800-RD
4
S800-RD
Rotary drive
The rotary drive for 2–4 pole devices can be delivered for assembly on the switching field
door. Switching is effortless due to the ergonomic design of the swivel lever. It is equipped
with a lock for the OFF position that prevents switching on of the S800 high performance
MCB.
The slot hole of the lock can accept up to 3 padlocks with lug diameters of 7 mm (not
included in delivery). Operation of the trigger and a view of the characteristics are not
prevented Additionally, a rotary drive can also be supplied to switch machines; it has a red
grip on a y ellow background.
The rotary drive on the switching field door is comprised of the following three components:
• Rotary handle S800-RHE-H, -EM
• Axle (500 mm) S800-RHE-S
IP54 kit for door mounting EAN Type code Order code piece kg pc.
IP54 Kit 26259 S800-RHE-IP54 1SDA060180R0001 0.08 1
4/78 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Auxiliary elements for S800
S800-IP9, S800-PLL, S800U-PLL
4
S800-IP9
Intermediate piece
The S800-IP9 intermediate piece fits the profile of the high performance MCB and is used to
fill in empty device slots. Thanks to its width of just 9mm, the slots of all devices of the
S800 range can be expanded using this intermediate piece.
Intermediate piece 9 mm EAN Type code Order code piece kg pc.
Intermediate piece 9 mm 08202 S800-IP9 2CCS800900R0031 0.01 1
S800-PLL
Padlock device
The S800-PLL padlock device safely prevents unintentional switching on and off. Simply
insert the lug of the padlock device through the borehole on the high performance MCB and
lock with a padlock with lug diameter Ø 4 mm (not included in delivery). Even when the high
performance MCB is secured with an padlock device against unintentional switching off,
tripping remains possible in case of overload or short-circuit by the S800-SOR, S800-UVR
and DDA800.
S800U-PLL
Locking device – for the American market
The S800U-PLL locking device prevents unintentional switch-on or off of the S800U high
performance MCB, or switch on/off by third parties. It is mounted at the side of the high
performance MCB and can only be removed using a special tool. A standardised American
padlock (not included in delivery) is hung onto the round recess on the locking device, which
can be secured by max six locks. Of course, tripping is possible by the S800-SOR or S800-
UVR in case of overload or short-circuit.
*High performance circuit breaker and lockout tag are not included in delivery
4/79
—
Auxiliary elements for S800
S800-CT, -RT, S800-ILS
4
S800-CT, -RT
Interchangeable adapter kit
The S800 interchangeable adapter kit allows the cable clamp – ring terminal connections
to be exchanged. Ring terminal connection -> Cage Terminal connection
The following is included in the S800-CT replaceable interchangeable adapter kit:
• Cage terminal
• Insulator
S800-ILS
Identification labelling system
The individual identification labelling system for ILS legend plates is a DIN A5 polyester foil
for inkjet and laser printers with high temperature resistance (if a laser printer is used
please check whether self-sticking foils with a thickness of 250 µm can be printed with it).
The 3M™9471 LE adhesive backing is UL-approved with Appl. No. MH 11410. The single
plates are butt-cut on one side. Can be manually labelled with ink, pen, pencil and felt pen.
—
Auxiliary elements for S800
S802-LINK
4
S802-LINK50
Pole connector up to 50 A
The pole connector S802-LINK50 can be used up to 50 A.
S802-LINK125
Pole connector up to 125 A
The pole connector S802-LINK125 can be used up to 125 A.
—
Auxiliary elements for S800
S800 Busbar system
4
S800 Busbar system
The S800 busbar system is comprised of:
Busbar S803-BB250/S804-BB250
Max. rated current In
Side feed A 125
Middle feed A 250
Conditional rated short-circuit current kA eff 100 with Tmax connected upstream
Poles 3/4
Rated operational voltage Ue
(AC) 50/60 Hz V 400/690
Rated insulation voltage Ui V 690
Rated impulse withstand voltage Uimp kV 8
Rated frequency Hz 50
Standard EN/IEC 60439-2
Material of rails E-Cu 58 half-standard, rolled F25
Material of insulation profile Material group I; UL94 V-0
Material of end caps Material group I; UL94 V-0
Free of halogen and phosphate
Busbar cross sections mm2 60
Overvoltage category III
Pollution degree 2
—
Auxiliary elements for S800
S800 Busbar system
4
—
Auxiliary elements for S800
27mm wide universal adapter S800
4
27mm wide universal adapter to mount S800 MCB on SMISSLINE TP system
The universal adapter with the new 9mm dummy housing is specially designed for the
High performance breaker S800. This allows to have a 27mm adapter on the SMISSLINE TP
busbar system. The S800 High performance MCB can be easily mounted and wired on the
universal adapter. The complete unit can be clicked on to the plug-in socket system quickly
and safely. The input wiring is then already finished.
• Max. Incoming 400A (T5/XT5) rated conditional short-circuit current Icc 40kA
(415V) with S800S
• Time-saving mounting of S800 MCB units up to 30% faster
than conventional DIN rail mounting
• Input wiring is already integrated in the SMISSLINE plug-in socket system
S800 1P ZLS97X ZLS965 ZLS965 ZLS97X S800 2P ZLS97X ZLS964 ZLS97X S800 3P ZLS97X ZLS964 ZLS97X ZLS97X ZLS965 S800 4P ZLS97X ZLS964 ZLS97X ZLS964 ZLS97X
C US C US C US C US C US C US C US C US C US C US C US C US C US C US
ZLS E210- ZLS ZLS E210- ZLS ZLS E210- ZLS ZLS ZLS E210- ZLS ZLS
In max. In max. In max. In max. In max. In max. In max. In max. In max. In max.
L1 - L2 - L3 SPV L1 - L2 - L3 L1 - L2 - L3 SPV L1 - L2 - L3 L1 - L2 - L3 SPV L1 - L2 - L3 L1 - L2 - L3 L1 - L2 - L3 SPV L1 - L2 - L3 L1 - L2 - L3
27 mm 27 mm 27 mm
1.5 PLE 1.5 PLE 1.5 PLE
—
Auxiliary elements for S800
27mm wide universal adapter S800
4
Unifix H
The Unifix H System with feed module up to 400 A provides the user a high standardised de-
sign of energy distribution. The wide range of assembly and adapter combinations which are
also available for the S800 range increase flexibility allowing for compact and cost-effective
design of the electrical distribution network. See dedicated System pro E power offering
—
Plug-in systems
UNIFIX rapid wiring system
4
UNIFIX – Rapid Wiring System taken up, connections needed to be checked, and
UNIFIX makes bench pre-cabling possible, with cabling times, with consequent cost savings.
installation in the switchboard only carried out at Unifix L means traditional wire cabling on the
a later time, without any limit to the types or supply side of the circuit-breakers can be re-
combination of apparatus you may need to in- placed. It is thanks to the characteristics of its
stall…and this becomes even easier, thanks to the connections that cabling can be done rapidly and
rigid coupled connectors, standardized for the without any possibility of error, obtaining a more
different types of apparatus. essential switchboard without conductors and
Unifix H allows modular and moulded-case cir- cabling ducts around. Flexibility is its strong
cuit-breakers up to 250A to be mounted on an ap- point: several independent circuits can be real-
paratus frame, which can be connected directly to ized on the same DIN rail, and circuit-breakers of
the rear busbar system. This means many fewer different types, with different polarity and char-
conductors circulating inside the switchboard acteristics can be mounted.
with considerable advantages in terms of space
For order codes and technical details please check the Distribution Switchgear Catalogue
1STC008001D0203, pages 3/19-20, 4/18-19-20, 5/50-51-52
4/86 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plug-in systems
UNIFIX rapid wiring system
4
—
Unifix H
—
Unifix L
5/1
—
Electrical installation solutions for buildings
Protection and safety
5
Index OVR Plus - Autoprotected SPDs Protector accessories 5/142
TNS/TT 230 V networks 5/66
Type 1 OVR non-pluggable Fuse Protection Devices
Single pole 5/10 OVR PV E 90 fuse switch disconnectors 5/147
TNC 230 V networks 5/12 SPDs for photovoltaic networks 5/68 E 90h fuseholders 5/149
TNS/TT 230 V 1Ph+N networks 5/14 E 90 PV fuse disconnectors 5/150
TNS/TT 230 V 3Ph+N networks 5/16 OVR WT E 90 PV 1500 fuse holder 5/151
Single pole neutral 5/18 SPDs for wind turbine networks 5/72 E 90 50/125 fuse disconnectors 5/152
E 90 CC fuseholders 5/153
Type T1-T2 OVR pluggable and non- Accessories for OVR 5/74 E 90 J fuse fuseholders 5/154
pluggable Cylindrical fuses E 9F 5/155
Single pole 5/20 OVR UL Version ILTS-E D0 Fuse-switch-disconnectors
TNC 230 and 400 V networks 5/24 OVR Type 2 Single pole 5/78 ISS D0 Fuse carriers 5/164
TNS/TT 230 1Ph+N and 3Ph+N OVR Type 2 Single phase networks 5/79 Busbars and accessories for ILTS-E
networks5/26 OVR Type 2 Delta networks 5/84 and ISS 5/166
TNS/TT 400 V 1Ph+N and 3Ph+N OVR Type 2 Split phase networks 5/86
networks5/28 OVR Type 2 Grounded Wye networks 5/87 Other Protection Devices
OVRHSP/OVRHSR Facility Wide Electronic Protection Devices for use
Type 2 OVR pluggable and non- Protection – 4,000A and below 5/94 behind 24 V DC Switch Mode Power
pluggable OVRHT3B Sub Distribution and Supplies5/168
TT/TNS/TNC 57 V networks 5/30 Panelboard – 400A and below 5/96 SQZ3 phase and sequence relay 5/171
TT/TNS/TNC 230 V networks 5/32 OVRHS3U Sub Distribution and E 236 undervoltage monitoring
QuickSafe® Single pole 230 V Panelboard – 400A and below 5/98 relays5/172
networks5/34 OVRHT3C Sub Distribution and ISL industrial insulation
QuickSafe® Single pole 400 V Panelboard – 400A and below 5/100 monitoring devices 5/175
networks5/38 OVRHLD Equipment Level Protection –
QuickSafe® TNC 230 V networks 5/42 100A and below 5/102 H+ Line
QuickSafe® TNC 400 V networks 5/44 H+Line products 5/180
QuickSafe® TNS 230 V networks 5/46 OVR data and telecom ISOLTESTER-DIG insulation
QuickSafe® TNS 400 V networks 5/48 OVR SL Series 5/106 monitoring devices 5/182
QuickSafe® TNS/TT 230 and 400 V OVR SL X Series 5/108 SELVTESTER insulation monitoring
1Ph+N networks 5/50 OVR D Series 5/110 devices for insulated networks
QuickSafe® TNS/TT 230 and 400 V OVR E Series 5/112 at 24 V AC/DC 5/184
3Ph+N networks 5/52 OVR H Series 5/114 QSD remote signalling panel 5/185
OVR SL 3-Wire Series 5/116 TI switchboards and devices
Type T2-T3 OVR Pluggable OVR SL LED 4-20 mA Series 5/118 for medical locations 5/186
QuickSafe® Single pole 230 and 440 V OVR Q Series 5/120 QSO selection table 5/187
networks5/56 OVR RTD Series 5/122 QSO switchboards and components
QuickSafe® TNC 230 V 3Ph OVR KT & KE Series 5/124 for medical locations 5/188
+ networks 5/58 OVR TN/RJ11 & ISDN/RJ45 Series 5/126
QuickSafe® TNS/TT 230 V 1Ph+N OVR TN, TNQ & SL TN Series 5/128
networks5/60 OVR Cat-5 & Cat-6 Series 5/130
QuickSafe® TT 230 and 400 V 3Ph+N OVR RS485, RS485Q & SL RS485 Series
networks5/62 OVR RF Series 5/132
OVR CCTV Series 5/136
Type T2-T3 OVR StreetLight OVR 240-16A 5/138
TT/TN 230 V 1Ph+N networks 5/64 OVR TV Series 5/140
5/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
OVR T1-T2, T2 and T2-T3 ranges.
The details make the difference
A complete range for your surge protection
5
5
OVR T1-T2 12.5, T2 and T2-T3 ranges The pluggable feature of ABB The end-of-life indicator of the SPD
are using same terminal as Pro M OVR T1-T2, T2 and T2-T3 surge signals the status of the device.
compact devices to guarantee protective devices (SPDs) facilitates A mechanical indicator turns from
a complete coordination and time maintenance. Should one or more worn green to red when the SPD reaches the
saving in wiring operation. cartridges need to be replaced, the end of its life, when the end-of-life in-
wires do not have to be removed. dicator is fitted.
The toggle of the miniature circuit A safety reserve system for an QuickSafe MOV technology extended
breaker indicates the status of the extended protection. T1-T2s and T2s. to SPD dedicated to D.C photovoltaic
OVR Plus range. These Surge Protective Devices are applications, bringing seft-protected
If the toggle is on, the surge protection equipped with two varistors per pole. feature (no back-up needed) up to 10
is active. If the toggle is off and can be If one varistor is damaged, the SPD kA PV short circuit current.
switched on again, the device has pro- gives advanced warning that it is
tected your equipment. If the toggle is approaching the end of its life while
off and cannot be swicthed on, the de- the other varistor continues to protect
vice must be changed. the equipment, allowing to perform
Preventive Maintenance.
5/4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR surge protective devices selection tables
Pro- Impulse Max. Nominal Follow Voltage Nominal Max. Type Order code
tected current dis- current current protec- voltage cont. op-
lines charge interrupt- tion level erating
5
—
Protection and safety
OVR surge protective devices selection tables
Pro- Impulse Max. Nominal Follow Voltage Nominal Max. Type code Order code
tected current dis- current current protec- voltage cont. op-
lines charge interrupt- tion level erating
5
current ing rating voltage
Iimp Imax
10/350 8/20 In Ifi Up Un Uc
kA kA kA kA kV V V
Uc 440 V
1 12.5 80 20 - 1.9 400 440 OVR T1-T2 12.5-440s P TS QS 2CTB815710R2900
1+1 12.5 80 20 - 1.9 400 440 OVR T1-T2 1N 12.5-440s P TS QS 2CTB815710R3000
3 12.5 80 20 - 1.9 400/690 440 OVR T1-T2 3L 12.5-440s P TS QS 2CTB815710R3500
3+1 12.5 80 20 - 1.9 400/690 440 OVR T1-T2 3N 12.5-440s P TS QS 2CTB815710R3600
4 12.5 80 20 - 1.9 400/690 440 OVR T1-T2 4L 12.5-440s P TS QS 2CTB815710R4000
1 12.5 80 20 - 1.9 400 440 OVR T1-T2 12.5-440s P QS 2CTB815710R4100
1+1 12.5 80 20 - 1.9 400 440 OVR T1-T2 1N 12.5-440s P QS 2CTB815710R4200
3 12.5 80 20 - 1.9 400/690 440 OVR T1-T2 3L 12.5-440s P QS 2CTB815710R4700
3+1 12.5 80 20 - 1.9 400/690 440 OVR T1-T2 3N 12.5-440s P QS 2CTB815710R4800
4 12.5 80 20 - 1.9 400/690 440 OVR T1-T2 4L 12.5-440s P QS 2CTB815710R5200
Neutral
1 50 100 50 0.1 1.4 230 275 OVR T1-T2 N 50-275s P QS 2CTB815710R5300
1 50 100 50 0.1 1.9 400 440 OVR T1-T2 N 50-440s P QS 2CTB815710R5300
Cartridges
1 12.5 80 20 - 1.4 230 275 OVR T1-T2 12.5-275s C QS 2CTB815710R2600
1 12.5 80 20 - 1.9 400 440 OVR T1-T2 12.5-440s C QS 2CTB815710R5500
1 50 100 50 - 1.4 230 275 OVR T1-T2 N 50-275s C QS 2CTB815710R2700
1 50 100 50 - 1.9 400 440 OVR T1-T2 N 50-440s C QS 2CTB815710R5600
Type 2 OVR non-pluggable
Uc 275 V
1 – 20 5 - 1.0 230 275 OVR T2 20-275 2CTB804200R0100
1 – 40 20 - 1.4 230 275 OVR T2 40-275 2CTB804201R0100
1 – 20 5 - 1.0 230 275 OVR T2 20-275 (x20) 2CTB804200R1100
1 – 40 20 - 1.4 230 275 OVR T2 40-275 (x20) 2CTB804201R1100
Type 2 OVR pluggable
Uc 75 V
1 – 20 5 - 0.3 57 75 OVR T2 20-75 P 2CTB803851R2800
1 – 20 5 - 0.3 57 75 OVR T2 20-75 P TS 2CTB803851R2700
2 – 20 5 - 0.3 57 75 OVR T2 2 20-75 P 2CTB803852R1700
2 – 20 5 - 0.3 57 75 OVR T2 2 20-75 P TS 2CTB803852R1600
Uc 275 V
1 2 40 20 - 1.25 230 275 OVR T2 40-275 P TS QS 2CTB803871R1700
1+1 2 40 20 - 1.25 230 275 OVR T2 1N 40-275 P TS QS 2CTB803972R0500
3 2 40 20 - 1.25 230/400 275 OVR T2 3L 40-275 P TS QS 2CTB803873R2500
4 2 40 20 - 1.25 230/400 275 OVR T2 4L 40-275 P TS QS 2CTB803873R5200
1 2 40 20 - 1.25 230 275 OVR T2 40-275 P QS 2CTB803871R2300
1+1 2 40 20 - 1.25 230 275 OVR T2 1N 40-275 P QS 2CTB803972R1100
3 2 40 20 - 1.25 230/400 275 OVR T2 3L 40-275 P QS 2CTB803873R2400
4 2 40 20 - 1.25 230/400 275 OVR T2 4L 40-275 P QS 2CTB803873R5600
1 2 40 20 - 1.4 230 275 OVR T2 40-275s P TS QS 2CTB815704R0000
1+1 2 40 20 - 1.4 230 275 OVR T2 1N 40-275s P TS QS 2CTB815704R0200
3 2 40 20 - 1.4 230/400 275 OVR T2 3L 40-275s P TS QS 2CTB815704R0600
4 2 40 20 - 1.4 230/400 275 OVR T2 4L 40-275s P TS QS 2CTB815704R1100
1 2 40 20 - 1.4 230 275 OVR T2 40-275s P QS 2CTB815704R1200
1+1 2 40 20 - 1.4 230 275 OVR T2 1N 40-275s P QS 2CTB815704R1400
3 2 40 20 - 1.4 230/400 275 OVR T2 3L 40-275s P QS 2CTB815704R1800
4 2 40 20 - 1.4 230/400 275 OVR T2 4L 40-275s P QS 2CTB815704R2300
1 6.25 80 20 - 1.4 230 275 OVR T2 80-275s P TS QS 2CTB815708R0000
1+1 6.25 80 20 - 1.4 230 275 OVR T2 1N 80-275s P TS QS 2CTB815708R0200
3 6.25 80 20 - 1.4 230/400 275 OVR T2 3L 80-275s P TS QS 2CTB815708R0600
4 6.25 80 20 - 1.4 230/400 275 OVR T2 4L 80-275s P TS QS 2CTB815708R1100
1 6.25 80 20 - 1.4 230 275 OVR T2 80-275s P QS 2CTB815708R1200
1+1 6.25 80 20 - 1.4 230 275 OVR T2 1N 80-275s P QS 2CTB815708R1400
3 6.25 80 20 - 1.4 230/400 275 OVR T2 3L 80-275s P QS 2CTB815708R1800
4 6.25 80 20 - 1.4 230/400 275 OVR T2 4L 80-275s P QS 2CTB815708R2300
—
Protection and safety
OVR surge protective devices selection tables
Pro- Impulse Max. Nominal Follow Voltage Nominal Max. Type code Order code
tected current dis- current current protec- voltage cont. op-
lines charge interrupt- tion level erating
5
—
Protection and safety
OVR surge protective devices selection tables
Pro- Impulse Max. Nominal Follow Voltage Nominal Max. Type code Order code
tected current dis- current current protec- voltage cont. op-
lines charge interrupt- tion level erating
5
current ing rating voltage
Iimp Imax
10/350 8/20 In Ifi Up Un Uc
kA kA kA kA kV V V
Neutral
1 6.25 80 30 0.1 2 400 440 OVR T2 N 80-440s P QS 2CTB815708R5400
1 2 80 30 0.1 1.4 400 440 OVR T2-T3 N 80-440 P QS 2CTB803973R2000
Cartridges
1 2 80 20 - 1.8 400 440 OVR T2 40-440 C QS 2CTB803876R0400
1 2 40 20 - 1.8 400 440 OVR T2-T3 40-440s C QS 2CTB815704R5500
1 6.25 80 20 - 1.8 400 440 OVR T2 80-440s C QS 2CTB815708R5500
1 6.25 80 30 - 1.4 400 440 OVR T2-T3 N 80-440 C QS 2CTB803886R0100
1 6.25 80 30 - 2 400 440 OVR T2 N 80-440s C QS 2CTB815708R5700
Uc 600V
1 2 40 20 - 2.3 400 600 OVR T2 40-600 P TS QS 2CTB803881R0500
3 2 40 20 - 2.3 400/690 600 OVR T2 3L 40-600 P TS QS 2CTB803883R2700
4 2 40 20 - 2.3 400/690 600 OVR T2 4L 40-600 P TS QS 2CTB803883R5300
Cartridges
1 - 40 20 - 2.3 400 600 OVR T2 40-600 C QS 2CTB803886R0400
Uc 760V
3 - 40 15 - 2.9 400/690 440 OVR T2 3L 40 400/690 P 2CTB803853R4500
3 - 40 15 - 2.9 400/690 440 OVR T2 3L 40 400/690 P TS 2CTB803853R4600
Cartridges
1 40 20 - 2.9 400 440 OVR T2 40-400/690 C 2CTB803854R1100
—
Protection and safety
OVR surge protective devices selection tables
Protected Impulse Max. Nominal Follow Voltage Nominal Max. cont. Type code Order code
lines current discharge current current protec- voltage operating
current interrupt- tion level voltage
5
ing rating
Iimp Imax
10/350 8/20 In Ifi Up Un Uc
kA kA kA kA kV V V
—
Protection and safety
OVR surge protective devices selection tables
Protected Total Impulse Max. Nominal Follow Voltage Nominal Max. cont. Type code Order code
lines Discharge current discharge current current protection voltage operating
Current current interrupting level voltage
5
rating
Itotal Iimp Imax
10/350 10/350 8/20 In Ifi Up Un Uc
kA kA kA kA kA kV V V
—
Protection and safety
OVR Type 1 surge protective devices, Single pole
Technical features
Types OVR T1 25-255-7 OVR T1 25-440-50 OVR T1 25-255
with auxiliary contact (TS) – – –
5
—
Protection and safety
OVR Type 1 surge protective devices, Single pole
Type 1 surge protective devices are designed to discharge high current surges without any destruction
of the installation. These surge protective devices are characterized by their capacity to withstand
impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
—
Protection and safety
OVR Type 1 surge protective devices TNC 230 V networks
Technical features
Types OVR T1 3L 25-255
with auxiliary contact (TS) OVR T1 3L 25-255 TS
5
Technology Spark-gap
Electrical features
Standard IEC 61643-1/EN 61643-11
Type/test class T1/I
Protected lines 3
Types of networks TNC
OVR T1 3L 25-255 Type of current AC 47-63 Hz
Voltage regulation of the system network ± 10 %
Nominal voltage Un [V] 230/400
Maximum continuous operating voltage Uc [V] 255
Maximum impulse current Iimp (10/350) [kA] 25
Maximum impulse current Tot. Iimp (10/350) [kA] 75
Nominal discharge current In (8/20) [kA] 25
Follow current interrupting rating Ifi [kA] 50
Voltage protection level Up at In [kV] ≤ 2.5
Voltage protection level Ures at 3 kA [kV] ≤ 0.9
TOV (Temporary (L-N: 5 s /N-PE: 200 ms) [V] 450/–
overvoltage) withstand Ut
Response time [ns] ≤ 100
Residual current IPE [µA] 10
Short-circuit withstand capability Isccr [kA] 50
Backup protection Fuse (gG) [A] ≤ 125
Circuit breaker (B or C [A] ≤ 125
curve)
Pluggable cartridge No
Integrated thermal disconnector –
State indicator TS Option
Safety reserve No
Auxiliary contact TS Option
Installation
Wire range (L, N, PE) Solid wire [mm²] 2.5…50
Stranded wire [mm²] 2.5…35
Stripping length (L, N, PE) [mm] 15
Tightening torque (L, N, PE) [Nm] 3.5
Auxiliary contact (TS)
Contact complement 1 NO - 1 NC
Minimum load 12 V DC - 10 mA
Maximum load 250 V AC - 1 A
Connection cross-section [mm²] 1.5
Miscellaneous characteristics
Stocking and operating temperature [°C] -40 to +80
Maximal Altitude [m] 2000
Degree of protection IP20
Fire resistance according to UL 94 V0
Dimensions height x width x depth [mm] 90 x 106.8 x 64.8
[inches] 3.54 x 4.2 x 2.55
with auxiliary contact (TS) height x width x depth [mm] 90 x 124.6 x 64.8
[inches] 3.54 x 4.91 x 2.55
5/13
—
Protection and safety
OVR Type 1 surge protective devices TNC 230 V networks
Type 1 surge protective devices are designed to discharge high current surges without any destruction
of the installation. These surge protective devices are characterized by their capacity to withstand
impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
—
Protection and safety
OVR Type 1 surge protective devices TNS/TT 230 V 1Ph+N networks
Technical features
Types OVR T1 1N 25-255 OVR T1 2L 25-255
with auxiliary contact (TS) OVR T1 1N 25-255 TS OVR T1 2L 25-255 TS
5
—
Protection and safety
OVR Type 1 surge protective devices TNS/TT 230 V 1Ph+N networks
Type 1 surge protective devices are designed to discharge high current surges without any destruction
of the installation. These surge protective devices are characterized by their capacity to withstand
impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
—
Protection and safety
OVR Type 1 surge protective devices TNS/TT 230 V 3Ph+N networks
Technical features
Types OVR T1 4L OVR T1 3N OVR T1 3N
25-255 25-255 25-255-7
5
—
Protection and safety
OVR Type 1 surge protective devices TNS/TT 230 V 3Ph+N networks
Type 1 surge protective devices are designed to discharge high current surges without any destruction
of the installation. These surge protective devices are characterized by their capacity to withstand
impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
—
Protection and safety
OVR Type 1 surge protective devices Single pole neutral
Technical features
Types OVR T1 25 N OVR T1 50 N OVR T1 100 N
with auxiliary contact (TS) – – –
5
—
Protection and safety
OVR Type 1 surge protective devices Single pole neutral
Type 1 surge protective devices are designed to discharge high current surges without any destruction
of the installation. These surge protective devices are characterized by their capacity to withstand
impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
Type 1 Neutral
Poles Impulse Follow Volt- Nominal Max. Bbn Order details Price Weight
current cur- age voltage cont. 3660308 1 piece 1 piece
Iimp rent pro- Un oper-
10/350 inter- tec- ating
rupt- tion volt-
ing level age
rating Up Uc
Ifi
—
Protection and safety
OVR Type 1+2 surge protective devices Single pole
Technical features
Types OVR T1-T2 12.5-275s P QS
with auxiliary contact (TS) OVR T1-T2 12.5-275s P TS QS
5
Technology Varistor
Electrical features
Standard IEC 61643-11/EN 61643-11
Type/test class T1-T2/I - II
OVR T1-T2 12.5- Protected lines 1
275s P QS
System network TT (L-N) - TNS - TNC
Type of current AC 47-63 Hz
Voltage regulation of the system network ± 20 %
Nominal system voltage Un [V] 230
Max. cont. operating voltage Uc [V] 275
Maximum impulse current Iimp (10/350) [kA] 12.5
Nominal discharge current In 8/20) [kA] 20
Maximum discharge current Imax (8/20) [kA] 80
Follow current interrupting rating Ifi [kA] -
Voltage protection level Up at In (L-N/N-PE/L-PE) [kV] 1.4/-/1.4
Voltage protection level Ures at 3 kA [kV] 0.5
TOV (Temporary overvoltage) withstand Ut (L-N: 5s./N-PE: 200ms) [V] 337/
Response time [ns] < 25
Short-circuit withstand capability Isccr [kA] 100
Backup protection fuse (gG) [A] ≤ 160
maximum rating circuit breaker (B or C curve) [A] ≤ 125
Pluggable cartridge Yes
Integrated thermal disconnector Yes
State indicator Yes
Safety reserve Yes
Auxiliary contact Yes (TS option)
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 … 35
stranded wire [mm²] 2.5 … 25
Stripping length (L, N, PE) [mm] 12.5
Tightening torque (L, N, PE) [Nm] 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC
Min. load 12 V DC - 10 mA
Max. load 250 V AC - 1A
Connection cross-section [mm²] 6.5
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80
Maximal Altitude [m] 5000
Degree of protection IP 20 - Indoor
Fire resistance according to UL 94 V-0
Dimensions
height x width x depth [mm] 88 x 17.8 x 76.7
[inches] 3.46 x 0.70 x 3.02
Dimensions with auxilary contact (TS)
height x width x depth [mm] 95.8 x 17.8 x 76.7
[inches] 3.77 x 0.70 x 3.02
Replacement Cartridges
Phase Product ID OVR T1-T2 12.5-275s C QS
2CTB815710R2600
Neutral Product ID -
5/21
—
Protection and safety
OVR Type 1+2 surge protective devices Single pole
5
Varistor GDT GDT Spark-gap + Varistor
IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
T1-T2/I - II T1-T2/I - II T1-T2/I - II T1+2/I - II
1 N N 1
TT (L-N) - TNS - TNC TT (N-PE) - TNS (N-PE) TT (N-PE) - TNS (N-PE) TT (L-N) - TNS - TNC
AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
± 10 % ± 20 % ± 10 % ± 10 %
400 230 400 230
440 275 440 255
12.5 50 50 25
20 50 50 25
80 100 100 60
- - - 15
1.9/-/1.9 -/1.4/- -/1.9/- 1.5/-/1.5
0.5 - - 1.0
581/ -/1200 -/1200 334/-
< 25 ≤10 ≤10 < 100
100 ≤100 ≤100 ≤50
≤ 160 - - ≤125
≤ 125 - - ≤125
Yes Yes Yes No
Yes No No Yes
Yes No No Yes
Yes No No No
Yes (TS option) No No Yes
1 NO - 1 NC 1 NO - 1 NC
12 V DC - 10 mA 12 V DC - 10 mA
250 V AC - 1A 250 VAC - 1 A
6.5 1.5
—
Protection and safety
OVR Type 1+2 surge protective devices Single pole
Type 1+2 surge protective devices are designed to discharge high current surges without any
destruction of the installation. These surge protective devices are characterized by their capacity to
withstand impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1+2 ABB surge protective devices have a high impulse current withstand capacity with ensuring
a low protection level (Up).
Type 1+2 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
Poles Impulse Max. Follow Voltage Nominal Max. Bbn Order details Weight
current dis- current protec- voltage cont. op- 3660 1 piece
Iimp charge inter- tion Un erating 308
10/350 current rupting level voltage
Imax rating Up Uc
8/20 Ifi
kg
kA kA kA kV V V EAN Type code Order code
1 12.5 80 - 1.4 230 275 524881 OVR T1-T2 12.5- 2CTB815710R0000 0.15
275s P TS QS
1 12.5 80 - 1.4 230 275 524959 OVR T1-T2 12.5- 2CTB815710R1200 0.15
275s P QS
1 12.5 80 - 1.9 400 440 525055 OVR T1-T2 12.5- 2CTB815710R2900 0.30
440s P TS QS
1 12.5 80 - 1.9 400 440 525123 OVR T1-T2 12.5- 2CTB815710R4100 0.30
440s P QS
1 50 100 - 1.4 230 275 525024 OVR T1-T2 N 50- 2CTB815710R2400 0.15
275s P QS
1 50 100 - 1.9 400 440 525192 OVR T1-T2 N 50- 2CTB815710R5300 0.14
440s P QS
1 25 60 15 1.5 230 255 510884 OVR T+2 25 -255 2CTB815101R0300 0.27
TS
5/23
—
Notes
5
5/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 1+2 surge protective devices TNC 230 and 400 V networks
Technical features
Types OVR T1-T2 3L 12.5- OVR T1-T2 3L 12.5-
275s P QS 440s P QS
5
with auxiliary contact (TS) OVR T1-T2 3L 12.5- OVR T1-T2 3L 12.5- OVR T1+2 3L 25-255 TS
275s P TS QS 440s P TS QS
Technology Varistor Varistor Spark-gap + Varistor
Electrical features
Standard IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
Type/test class T1-T2/I - II T1-T2/I - II T1+2/I - II
Protected lines 3 3 3
System network TNC TNC TNC
Type of current AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ± 20 % ± 10 % ± 10 %
Nominal system voltage Un [V] 230/400 400/690 230/400
Max. cont. operating voltage Uc [V] 275 440 255
Maximum impulse current Iimp (10/350) [kA] 12.5 12.5 25
Max.Imp current Tot Iimp (10/350) [kA] 37.5 37.5 75
Nominal discharge current In (8/20) [kA] 20 20 25
Maximum discharge current Imax (8/20) [kA] 80 80 60
Follow current interrupting rating Ifi [kA] - - -
Voltage protection level Up at In (L-N/N-PE/L-PE) [kV] -/-/1.4 -/-/2 -/-/1.5
Voltage protection level Ures at 3 kA [kV] 0.5 0.8 1.0
TOV (Temporary overvoltage) withstand Ut [V] 337/– 581/– 334/-
(L-N: 5s./N-PE: 200ms)
Response time [ns] ≤ 25 ≤ 25 < 100
Short-circuit withstand capability Isccr [kA] 100 100 ≤50
Backup fuse (gG) [A] ≤ 160 ≤ 160 ≤125
protection circuit breaker (B or C) [A] ≤ 125 ≤ 125 ≤125
maximum
rating
Pluggable cartridge Yes Yes No
Integrated thermal disconnector Yes Yes Yes
State indicator Yes Yes Yes
Safety reserve Yes Yes No
Auxiliary contact Yes (TS option) Yes (TS option) Yes
Installation
Wire range solid wire [mm²] 2.5 … 35 2.5 … 35 2.5 … 50
(L, N, PE) stranded wire [mm²] 2.5 … 25 2.5 … 25 2.5 … 35
Stripping length (L, N, PE) [mm] 12.5 12.5 15
Tightening torque (L, N, PE) [Nm] 2.8 2.8 3.5
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Min. load 12 DC - 10 mA 12 DC - 10 mA 12 V DC - 10 mA
Max. load 250 V AC - 1A 250 V AC - 1A 250 VAC - 1 A
Connection cross-section [mm²] 1.5 1.5 1.5
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80 -40 to +80 -40 to +80
Maximal Altitude [m] 5000 5000 2000
Degree of protection IP 20 - Indoor IP 20 - Indoor IP 20 - Indoor
Fire resistance according to UL 94 V-0 V-0 V0
Dimensions
height x width x depth [mm] 88 x 53.4 x 76.7 88 x 106.8 x 76.7
[inches] 3.46 x 2.1 x 3.02 3.46 x 4.2 x 3.02
Dimensions with auxilary contact (TS)
height x width x depth [mm] 95.8 x 53.4 x 76.7 95.8 x 106.8 x 76.7 93.5 x 106.8 x 65
[inches] 3.77 x 2.1 x 3.02 3.77 x 4.2 x 3.02 3.68 x 4.2 x 2.56
Replacement Cartridges
Phase Product ID OVR T1-T2 12.5-275s C QS OVR T1-T2 12.5-440s C QS OVR T1+2 25-255 c
2CTB815710R2600 2CTB815710R5500 2CTB815101R3700
5/25
—
Protection and safety
OVR Type 1+2 surge protective devices TNC networks
Type 1+2 surge protective devices are designed to discharge high current surges without any
destruction of the installation. These surge protective devices are characterized by their capacity to
withstand impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1+2 ABB surge protective devices have a high impulse current withstand capacity with ensuring
a low protection level (Up).
Type 1+2 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
Po Impulse Max Volt- Nominal Max. Bbn Order details Weight
les current dis- age voltage cont. 3660308 1 piece
Iimp charge pro- Un oper-
10/350 current tection ating
Imax level voltage
8/20 Up Uc
—
Protection and safety
OVR Type 1+2 surge protective devices TNS/TT 230 1Ph+N and 3Ph+N networks
Technical features
Types OVR T1-T2 1N 12.5-275s P QS OVR T1-T2 3N 12.5-275s P QS
with auxiliary contact (TS) OVR T1-T2 1N 12.5-275s P TS QS OVR T1-T2 3N 12.5-275s P TS QS
5
—
Protection and safety
OVR Type 1+2 surge protective devices TNS/TT 230 1Ph+N and 3Ph+N networks
5
Varistor Varistor + GDT Spark-gap + GDT Spark-gap
IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
T1-T2/I - II T1+2/I - II T1+2/I - II T1+2/I - II
3+N 1+N 3+N 3+N
TNS TT - TNS TT - TNS TNS
AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
± 20 % ± 10 % ± 10 % ± 10 %
230/400 230 230/400 230/400
275 255 255 255
12.5 25 25 25
50 50 100 100
20 25 25 25
80 60 60 60
- 15 15 15
2.8/1.4/1.4 1.5 1.5 1.5
0.5 1.0 1.0 1.0
337/ 334/- 334/- 334/-
1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
12 V DC - 10 mA 12 V DC - 10 mA 12 V DC - 10 mA 12 V DC - 10 mA
250 V AC - 1A 250 V AC - 1 A 250 V AC - 1 A 250 V AC - 1 A
1.5 1.5 1.5 1.5
OVR T1-T2 12.5-275s C QS OVR T1+2 25-255 c OVR T1+2 25-255 c OVR T1+2 25-255 c
2CTB815710R2600 2CTB815101R3700 2CTB815101R3700 2CTB815101R3700
5/28 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 1+2 surge protective devices TNS/TT 400 V 1Ph+N and 3Ph+N networks
Technical features
Types OVR T1-T2 1N 12.5- OVR T1-T2 3N 12.5- OVR T1-T2 4L 12.5-
440s P QS 440s P QS 440s P QS
5
with auxiliary contact (TS) OVR T1-T2 1N 12.5- OVR T1-T2 3N 12.5- OVR T1-T2 4L 12.5-
440s P TS QS 440s P TS QS 440s P TS QS
Technology Varistor + GDT Varistor + GDT Varistor
Electrical features
Standard IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
Type/test class T1-T2/I - II T1-T2/I - II T1-T2/I - II
Protected lines 1+1 3+1 4
System network TT- TNS TT- TNS TNS
Type of current AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ± 10 % ± 10 % ± 10 %
Nominal system voltage Un [V] 400 400/690 400/690
Max. cont. operating voltage Uc [V] 440 440 440
Maximum impulse current Iimp (10/350) [kA] 12.5 12.5 12.5
Max.Imp current Tot Iimp (10/350) [kA] 25 50 50
Nominal discharge current In (8/20) [kA] 20 20 20
Maximal discharge current Imax (8/20) kA [kA] 80 80 80
Follow current interrupting rating Ifi [kA]
Voltage protection level Up at In (L-N/N-PE/L-PE) [kV] 1.9/1.9/2 1.9/1.9/2 3.8/1.9/1.9
Voltage protection level Ures at 3 kA [kV] 0.8 0.8 0.8
TOV (Temporary overvoltage) withstand Ut (L-N: [V] 581/1200 581/1200 581/
5s./N-PE: 200ms)
Response time [ns] ≤ 25 ≤ 25 ≤ 25
Short-circuit withstand capability Isccr [kA] 100 100 100
Backup protection fuse (gG) [A] ≤ 160 ≤ 160 ≤ 160
maximum rating circuit breaker [A] ≤ 125 ≤ 125 ≤ 125
(B or C curve)
Pluggable cartridge Yes Yes Yes
Integrated thermal disconnector Yes Yes Yes
State indicator Yes Yes Yes
Safety reserve Yes Yes Yes
Auxiliary contact Yes (TS option) Yes (TS option) Yes (TS option)
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 … 35 2.5 … 35 2.5 … 35
stranded wire [mm²] 2.5 … 25 2.5 … 25 2.5 … 25
Stripping length (L, N, PE) [mm] 12.5 12.5 12.5
Tightening torque (L, N, PE) [Nm] 2.8 2.8 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Min. load 12 V DC - 10 mA 12 V DC - 10 mA 12 V DC - 10 mA
Max. load 250 V AC - 1 A 250 V AC - 1 A 250 V AC - 1 A
Connection cross-section [mm²] 1.5 1.5 1.5
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80 -40 to +80 -40 to +80
Maximal Altitude [m] 5000 5000 5000
Degree of protection IP 20 - Indoor IP 20 - Indoor IP 20 - Indoor
Fire resistance according to UL 94 V-0 V-0 V-0
Dimensions
height x width x depth [mm] 88 x 53.4 x 76.7 88 x 124.6 x 76.7 88 x 142.4 x 76.7
[in] 3.46 x 2.1 x 3.02 3.46 x 4.91 x 3.02 3.46 x 5.61 x 3.02
Dimensions with auxilary contact (TS)
height x width x depth [mm] 95.8 x 53.4 x 76.7 95.8 x 124.6 x 76.7 95.8 x 142.4 x 76.7
[in] 3.77 x 2.1 x 3.02 3.77 x 4.91 x 3.02 3.77 x 5.61 x 3.02
Replacement Cartridges
Phase Product ID OVR T1-T2 12.5-440s C QS OVR T1-T2 12.5-440s C QS OVR T1-T2 12.5-440s C QS
2CTB815710R5500 2CTB815710R5500 2CTB815710R5500
Neutral Product ID OVR T1-T2 N 50-440s C QS OVR T1-T2 N 50-440s C QS
2CTB815710R5600 2CTB815710R5600
5/29
—
Protection and safety
OVR Type 1+2 surge protective devices TNS/TT 400 V 1Ph+N and 3Ph+N networks
Type 1+2 surge protective devices are designed to discharge high current surges without any destruc-
tion of the installation. These surge protective devices are characterized by their capacity to withstand
impulse current with 10/350 µs wave form which simulate natural lightning current.
5
Type 1+2 ABB surge protective devices have a high impulse current withstand capacity with ensuring
a low protection level (Up).
Type 1+2 SPDs can be installed at the entrance in the main switch board for a global protection of the
electrical installation.
OVR T1-T2
1N 12.5-440s
P TS QS
Poles Impulse Max. Follow Voltage Nominal Max. cont. Bbn Order details Weight
current discharge current inter- protec- voltage operating 3660 1 piece
Iimp current rupting tion level Un voltage 308
10/350 Imax 8/20 rating Ifi Up Uc
—
Protection and safety
OVR Type 2 surge protective devices for 57 V networks
Technical features
Types OVR T2 20-75 P OVR T2 2 20-75 P
with auxiliary contact (TS) OVR T2 20-75 P TS OVR T2 2 20-75 P TS
5
—
Protection and safety
OVR Type 2 surge protective devices for 57 V networks
Type 2 surge protective devices are designed to protect electric installations and sensitive equipment
against indirect surges with ensuring a low protection level (Up). They are characterized by their
capacity to safely discharge current with 8/20 μs wave form.
5
Type 2 pluggable - Uc 75 V
Po Max dis- Nomi- Volt- Nominal Max. Bbn Order details Weight
les charge nal age voltage cont. 3660308 1 piece
current dis- pro- Un oper-
Imax charge tection ating
8/20 current level voltage
In Up Uc
—
Protection and safety
OVR Type 2 surge protective devices non pluggable
Technical features
Types OVR T2 20-275 OVR T2 40-275
with auxiliary contact (TS) - -
5
—
Protection and safety
OVR Type 2 surge protective devices non pluggable
Type 2 surge protective devices are designed to protect electric installations and sensitive equipment
against indirect surges with ensuring a low protection level (Up). They are characterized by their
capacity to safely discharge current with 8/20 μs wave form.
5
Type 2 non pluggable - Uc 275 V
Po Max dis- Nomi- Volt- Nominal Max. Bbn Order details Weight
les charge nal age voltage cont. 3660308 1 piece
current dis- pro- Un oper-
Imax charge tection ating
8/20 current level voltage
In Up Uc
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
230 V networks
Technical features
Types OVR T2 40-275 P QS OVR T2 40-275s P QS
with auxiliary contact (TS) OVR T2 40-275 P TS QS OVR T2 40-275s P TS QS
5
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
230 V networks
OVR T2 40-350 P QS OVR T2 80-275s P QS OVR T2-T3 N 80-275 P QS OVR T2 N 80-350 P QS OVR T2 N 80-275s P QS
OVR T2 40-350 P TS QS OVR T2 80-275s P TS QS
5
Varistor Varistor GDT GDT GDT
IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
T2/II T2/II T2-T3/II-III T2/II T2
1 1 1 1 1
TT(L-N)-TNS-TNC TT(L-N)-TNS-TNC TT (N-PE)-TNS(N-PE) TT (N-PE)-TNS(N-PE) TT(N-PE)-TNS(N-PE)
AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
± 50 % ± 20 % ± 20 % ± 50 % ± 20 %
230 230 230 230 230
350 275 275 350 275
375 - - - -
415 - - - -
40 80 80 80 80
2 6.25 2 2 6.25
20 20 30 30 30
1.5/-/1.5 1.4/-/1.4 -/1.4/- -/1.4/- -/1.4/-
1 0.5 - - -
1.05 0.7 - - -
1.2 0.9 - - -
455/- 337/ -/1200 -/1200 -/1200
≤ 25 ≤ 25 < 25 < 25 < 25
100 100 - - 100
≤ 125 ≤ 160 ≤ 125 ≤ 125 ≤160
≤ 125 ≤ 125 ≤ 125 ≤ 125 ≤125
Yes Yes Yes Yes Yes
Yes Yes - - -
Yes Yes No No No
No Yes No No No
Yes (TS option) Yes (TS option) No No No
1 NO- 1 NC 1 NO- 1 NC - - -
12 V DC - 10 mA 12 V DC - 10 mA - - -
250 V AC - 1 A 250 V AC - 1 A - - -
1.5 1.5 - - -
-40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80
5000 5000 5000 5000 5000
IP 20 IP 20 - Indoor IP 20 - Indoor IP 20 - Indoor IP 20 - Indoor
V0 V-0 V-0 V-0 V0
88 x 17.8 x 65.3 88 x 17.8 x 76.7 88 x 17.8 x 65.3 88 x 17.8 x 65.3 88 x 17.8 x 76.7
3.46 x 0.7 x 2.57 3.46 x 0.7 x 3.02 3.46 x 0.7 x 3.02 3.46 x 0.7 x 3.02 3.45 x 0.7 x 3.02
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
230 V networks
Type 2 surge protective devices are designed to protect electric installations and sensitive equipment
against indirect surges with ensuring a low protection level (Up). They are characterized by their
capacity to safely discharge current with 8/20 µs wave form.
5
Type 2 pluggable
Poles Max Nomi- Voltage Nomi- Max. Bbn Order details Weight
dis- nal dis- protec- nal cont. op- 3660308 1 piece
OVR T2 40-275 P QS charge charge tion voltage erating
current current level Un voltage
Imax In Up Uc
8/20
—
Notes
5
5/38 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
400 V networks
Technical features
Types OVR T2 40-440 P QS OVR T2 40-440s P QS OVR T2 80-440s P QS
with auxiliary contact (TS) OVR T2 40-440 P TS QS OVR T2 40-440s P TS QS OVR T2 80-440s P TS QS
5
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
400 V networks
5
Varistor GDT GDT
1.6 - -
1.7 - -
1.9 - -
792/- -/1200 -/1200
- -
≤ 25 < 25 < 25
100 - 100
≤ 125 ≤ 125 ≤ 160 A
≤ 125 ≤ 125 ≤ 160 A
Yes Yes No
Yes Yes -
Yes Yes No
No No No
Yes No No
1 NO - 1 NC - -
12 V DC - 10 mA - -
250 V AC - 1A - -
5/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
400 V networks
Technical features
Types OVR T2 40-440 P QS OVR T2 40-440s P QS OVR T2 80-440s P QS
with auxiliary contact (TS) OVR T2 40-440 P TS QS OVR T2 40-440s P TS QS OVR T2 80-440s P TS QS
5
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices Single pole
400 V networks
5
1.5 1.5
OVR T2 40-600 C QS -
2CTB803886R0400
- OVR T2-T3 N 80-440 C QS OVR T2 N 80-440s C QS
2CTB803886R0100 2CTB815708R2800
Type 2 surge protective devices are designed to protect electric installations and sensitive equipment
against indirect surges with ensuring a low protection level (Up). They are characterized by their
capacity to safely discharge current with 8/20 µs wave form.
Type 2 pluggable
Poles Max Nomi- Volt- Nominal Max. Bbn Order details Weight
dis- nal dis- age voltage cont. 3660308 1 piece
charge charge pro- Un oper-
current current tec- ating
Imax In tion volt-
8/20 level age
Up Uc
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices
TNC 230 V networks
Technical features
Types OVR T2 3L 40- OVR T2 3L 40- OVR T2 3L 80- OVR T2 3L 40-
275 P QS 275s P QS 275s P QS 350 P QS
5
with auxiliary contact (TS) OVR T2 3L 40- OVR T2 3L 40- OVR T2 3L 80- OVR T2 3L 40-
275 P TS QS 275s P TS QS 275s P TS QS 350 P TS QS
Technology Varistor Varistor Varistor Varistor
Electrical features
Standard IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/EN
61643-11 61643-11 61643-11 61643-11
Type/test class T2/II T2/II T2/II T2/II
Protected lines 3 3 3 3
System network TNC TNC TNC TNC
Type of current AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ± 20 % ± 20 % ± 20 % ± 50 %
Nominal system voltage Un (L-PEN/L-L) [V] 230/400 230/400 230/400 230/400
Max. cont. operating voltage Uc [V] 275 275 275 350
Nominal dc voltage Un dc L-PE/Un dc L-L [V dc] 320/640 - - 375/750
Max. dc. cont. operating voltage Ucdc [V dc] 355/710 - - 415/830
L-PE/Ucdc L-L
Maximum discharge current Imax (8/20) [kA] 40 40 80 40
Maximum impulse current Iimp (10/350) [kA] 2 2 6.25 2
Nominal discharge current In (8/20) [kA] 20 20 20 20
Voltage protection level Up at In (L-PE) [kV] 1.25 1.4 1.4 1.5
Voltage protection level Ures at 3kA [kV] 0.8 0.5 0.5 1.0
Voltage protection level Ures at 5kA [kV] 0.85 0.7 0.7 1.05
Voltage protection level Ures at 10kA [kV] 1.0 0.9 0.9 1.2
TOV (Temporary overvoltage) withstand Ut [V] 337/- 337/- 337/- 455/-
(L-N: 5s./N-PE: 200ms)
Uoc [kV] - - - -
Response time [ns] ≤ 25 ≤ 25 ≤ 25 ≤ 25
Short-circuit withstand capability Isccr [kA] 100 100 100 100
Backup fuse (gG) [A] ≤ 125 ≤ 160 ≤ 160 ≤ 125
protection circuit breaker [A] ≤ 125 ≤ 125 ≤ 125 ≤ 125
maximum (B or C curve)
rating
Pluggable cartridge Yes Yes Yes Yes
Integrated QuickSafe® technology Yes Yes Yes Yes
State indicator Yes Yes Yes Yes
Safety reserve No Yes Yes No
Auxiliary contact Yes (TS option) Yes (TS option) Yes (TS option) Yes (TS option)
Installation
Wire range solid wire [mm²] 2.5 … 35 2.5 … 35 2.5 … 35 2.5 … 35
(L, N, PE) stranded wire [mm²] 2.5 … 25 2.5 … 25 2.5 … 25 2.5 … 25
Stripping length (L, N, PE) [mm] 12.5 12.5 12.5 12.5
Tightening torque (L, N, PE) [Nm] 2.8 2.8 2.8 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Min. load 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA
Max. load 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A
Connection cross-section [mm²] 1.5 1.5 1.5 1.5
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80 -40 to +80 -40 to +80 -40 to +80
Maximal Altitude [m] 5000 5000 5000 5000
Degree of protection IP 20 IP 20 IP 20 IP 20
Fire resistance according to UL 94 V0 V-0 V-0 V0
5/43
—
Protection and safety
OVR Type 2 surge protective devices TNC 230 V networks,
pluggable and non-pluggable versions
Technical features
Types OVR T2 3L 80-275s P QS OVR T2 3L 40-350 P QS
with auxiliary contact (TS) OVR T2 3L 80-275s P TS QS OVR T2 3L 40-350 P TS QS
5
Dimensions
height x width x depth [mm] 88 x 53.4 x 76.7 85 x 53.4 x 64.8
[inches] 3.46 x 2.1 x 3.02 3.35 x 2.10 x 2.55
With Auxiliary Contact (TS)
height x width x depth [mm] 95.8 x 53.4 x 76.7 96 x 53.4 x 64.8
[inches] 3.77 x 2.1 x 3.02 3.78 x 2.10 x 2.55
Replacement Cartridges
Phase Product ID OVR T2 80-275s C QS OVR T2 40-350 C QS
2CTB8157084R2600 2CTB803886R1000
Neutral Product ID - -
Type 2 surge protective devices are designed to protect electric installations and sensitive
equipment against indirect surges with ensuring a low protection level (Up). They are
characterized by their capacity to safely discharge current with 8/20 µs wave form.
Type 2 pluggable
Po Max Nomi- Volt- Nominal Max. Bbn Order details Weight
les dis- nal dis- age voltage cont. 3660308 1 piece
charge charge pro- Un oper-
current current tec- ating
OVR T2 3L 40-275 P QS Imax In tion voltage
8/20 level Uc
Up
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices
TNC 400 V networks
Technical features
Types OVR T2 3L 40- OVR T2 3L 80- OVR T2 3L
440 P QS 440s P QS 40 400/690 P
5
with auxiliary contact (TS) OVR T2 3L 40- OVR T2 3L 80- OVR T2 3L OVR T2 3L 40-
440 P TS QS 440s P TS QS 40 400/690 P TS 600 P TS QS
Technology Varistor Varistor Varistor Varistor
Electrical features
Standard IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/EN
61643-11 61643-11 61643-11 61643-11
Type/test class T2/II T2/II T2/II T2/II
Protected lines 3 3 3 3
System network TNC - IT (230) TNC - IT (230) TNC - IT (400) TNC - IT (230)
Type of current AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ± 10% ± 10% ± 10% ± 50 %
Nominal system voltage Un (L-PEN/L-L) [V] 400/690 400/690 400/690 400/690
Max. cont. operating voltage Uc [V] 440 440 440 600
Nominal dc voltage Un dc L-PE/Un dc L-L [V dc] 495/990 - - 650/990
Max. dc. cont. operating voltage Ucdc [V dc] 545/1090 - - 715/1090
L-PE/Ucdc L-L
Maximum discharge current Imax (8/20) [kA] 40 80 40 40
Maximum impulse current Iimp (10/350) [kA] 2 6.25 2 2
Nominal discharge current In (8/20) [kA] 20 20 15 20
Voltage protection level Up at In (L-PE) [kV] 1.8 2.1 2.9 2.3
Voltage protection level Ures at 3kA [kV] 1.25 1.25 2.1 1.6
Voltage protection level Ures at 5kA [kV] 1.35 1.35 2.2 1.7
Voltage protection level Ures at 10kA [kV] 1.55 1.55 2.3 1.9
TOV (Temporary overvoltage) [V] 581/ 581/- 910/- 792/-
withstand Ut (L-N: 5s./N-PE: 200ms)
Response time [ns] < 25 < 25 < 25 < 25
Short-circuit withstand capability Isccr [kA] 100 100 100 100
Backup protection fuse (gG) [A] ≤ 125 ≤ 160 ≤ 50 ≤ 125
maximum rating circuit breaker [A] ≤ 125 ≤ 126 ≤ 50 ≤ 125
(B or C curve)
Pluggable cartridge Yes Yes Yes Yes
Integrated QuickSafe® technology Yes Yes No Yes
State indicator Yes Yes Yes Yes
Safety reserve No Yes No No
Auxiliary contact Yes (TS option) Yes (TS option) Yes (TS option) Yes
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 … 35 2.5 … 35 2.5 … 36 2.5 … 36
stranded wire [mm²] 2.5 … 25 2.5 … 25 2.5 … 25 2.5 … 25
Stripping length (L, N, PE) [mm] 2.8 2.8 2.8 2.8
Tightening torque (L, N, PE) [Nm]
Auxiliary contact (TS) 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Contacts information 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA
Min. load 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A
Max. load 1.5 1.5 1.5 1.5
Connection cross-section [mm²]
Miscellanous characteristics
Stocking and operating temperature °C -40 to +80 -40 to +80 -40 to +80 -40 to +80
Maximal Altitude [m] 5000 5000 5000 5000
Degree of protection IP 20 IP 20 IP 20 IP 20
5/45
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices
TNC 400 V networks
Technical features
Types OVR T2 3L 40- OVR T2 3L 80- OVR T2 3L
440 P QS 440s P QS 40 400/690 P
5
with auxiliary contact (TS) OVR T2 3L 40- OVR T2 3L 80- OVR T2 3L OVR T2 3L 40-
440 P TS QS 440s P TS QS 40 400/690 P TS 600 P TS QS
Fire resistance according to UL 94 V-0 V-0 V-0 V-0
Dimensions
height x width x depth mm 88 x 53.4 x 65.3 88 x 53.4 x 76.7 88 x 53.4 x 64.8
inches 3.46 x 2.1 x 2.57 3.46 x 2.1 x 3.02 3.46 x 2.1 x 2.55
With Auxiliary Contact (TS)
height x width x depth mm 95.8 x 53.4 x 65.3 95.8 x 53.4 x 76.7 96 x 53.4 x 64.8 95.8 x 53.4 x 65.3
inches 3.77 x 2.1 x 2.57 3.77 x 2.1 x 3.02 3.78 x 2.1 x 2.55 3.77 x 2.1 x 2.57
Replacement Cartridges
Phase Product ID OVR T2 40-440 C QS OVR T2 80-440s C QS OVR T2 40 400/690 C OVR T2 40-600 C QS
2CTB803876R0400 2CTB815708R5500 2CTB803854R1100 2CTB803886R0400
Neutral Product ID - - - -
Type 2 surge protective devices are designed to protect electric installations and sensitive
equipment against indirect surges with ensuring a low protection level (Up). They are
characterized by their capacity to safely discharge current with 8/20 μs wave form.
Po Max Nomi- Volt- Nominal Max. Bbn Order details Weight
les dis- nal dis- age voltage cont. 3660308 1 piece
charge charge pro- Un oper-
current current tec- ating
Imax In tion voltage
OVR T2 3L 40-440 P QS 8/20 level Uc
Up
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices
TNS 230 V networks
Technical features
Types OVR T2 4L 40-275 P QS OVR T2 4L 40-275s P QS OVR T2 4L 80-275s P QS
with auxiliary contact (TS) OVR T2 4L 40-275 P TS QS OVR T2 4L 40-275s P TS QS OVR T2 4L 80-275s P TS QS
5
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices
TNS 230 V networks
Type 2 surge protective devices are designed to protect electric installations and sensitive
equipment against indirect surges with ensuring a low protection level (Up). They are
characterized by their capacity to safely discharge current with 8/20 µs wave form.
5
Type 2 pluggable - Uc 275 V
Po Max Nomi- Volt- Nominal Max. Bbn Order details Weight
les dis- nal dis- age voltage cont. 3660308 1 piece
charge charge pro- Un oper-
current current tec- ating
OVR T2 4L 40-275 P QS Imax In tion voltage
8/20 level Uc
Up
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS 400 V networks
Technical features
Types OVR T2 4L 40-440 P QS OVR T2 4L 80-440s P QS
with auxiliary contact (TS) OVR T2 4L 40-440 P TS QS OVR T2 4L 80-440s P TS QS OVR T2 4L 40-600 P TS QS
5
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS 400 V networks
Technical features
Types OVR T2 4L 40-440 P QS OVR T2 4L 80-440s P QS
with auxiliary contact (TS) OVR T2 4L 40-440 P TS QS OVR T2 4L 80-440s P TS QS OVR T2 4L 40-600 P TS QS
5
Fire resistance according to UL 94 V0 V0 V0
Dimensions
height x width x depth mm 88 x 71.2 x 65.3 88 x 71.2 x 69.4
inches 3.46 x 2.8 x 2.57 3.46 x 2.8 x 2.57
Dimensions with auxilary contact (TS)
height x width x depth mm 95.8 x 142.4 x 69 95 x 71.2 x 69.4 95.8 x 71.2 x 65.3
inches 3.77 x 2.8 x 2.57 3.77 x 2.8 x 2.57 3.77 x 2.8 x 2.57
Replacement Cartdriges
Phase Product ID OVR T2 40-440 C QS OVR T2 80-440s C QS OVR T2 40-600 C QS
2CTB803876R0400 2CTB815708R5500 2CTB803886R0400
Type 2 surge protective devices are designed to protect electric installations and sensitive
equipment against indirect surges with ensuring a low protection level (Up). They are char-
acterized by their capacity to safely discharge current with 8/20 μs wave form.
OVR T2 Pluggable
Pro Max Nomi- Volt- Nomi- Max. Bbn Order details Weight
tected dis- nal age nal cont. 3660308 1 piece
lines charge current pro- volt- oper-
current In 8/20 tec- age ating
Imax tion volt-
OVR T2 4L 20-275 8/20 level age
Up Un Uc
kA kV V V EAN Type code Order code kg
4 40 20 1,8 440 440 519894 OVR T2 4L 40-440 P 2CTB803873R5100 0.45
QS
4 40 20 1,8 440 440 519900 OVR T2 4L 40-440 P 2CTB803873R5300 0.45
TS QS
4 80 20 1,8 440 440 525635 OVR T2 4L 80-440s P 2CTB815708R5200 0.6
QS
4 80 20 1,8 440 440 525598 OVR T2 4L 80-440s P 2CTB815708R4000 0.6
TS QS
4 40 20 2,3 440 600 520685 OVR T2 4L 40-600 P 2CTB803883R5300 0.45
TS QS
5/50 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS/TT
230 and 400 V 1Ph+N networks
Technical features
Types OVR T2 1N OVR T2 1N OVR T2 1N OVR T2 1N
40-275 P QS 40-275s P QS 80-275s P QS 40-350 P QS
5
with auxiliary contact (TS) OVR T2 1N 40- OVR T2 1N 40- OVR T2 1N 80- OVR T2 1N 40- OVR T2 1N 40-
275 P TS QS 275s P TS QS 275s P TS QS 350 P TS QS 440 P TS QS
Technology Varistor + GDT Varistor + GDT Varistor + GDT Varistor + GDT Varistor + GDT
Electrical features
Standard IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/EN IEC 61643-11/
61643-11 61643-11 61643-11 61643-11 EN61643-11
Type/test class T2/II T2/II T2/II T2/II T2/II
Protected lines 1+1 1+1 1+1 1+1 1+1
System network TT - TNS TT - TNS TT - TNS TT - TNS TT-TNS
Type of current AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ± 20 % ± 20 % ± 20 % ± 50 % ±10 %
Nominal system voltage Un [V] 230 230 230 230 400
Max. cont. operating voltage Uc [V] 275 275 275 350 440
Maximum discharge current Imax (8/20) [kA] 40 40 80 40 40
Maximum impulse current Iimp (10/350) [kA] 2 2 6.25 2 2
Nominal discharge current In (8/20) [kA] 20 20 20 20 20
Total Current [kA] 80 80 80 80 80
Voltage protection level Up at In [kV] 1.25/1.4/1.5 1.4/1.4/1.5 1.4/1.4/1.5 1.5/1.4/1.6 1,8/1,4/1,9
(L-N/N-PE/L-PE)
Voltage protection level Ures at 3 kA [kV] 0.8/1.4/0.85 0.8/1.4/0.85 0.8/1.4/0.85 1.0/1.4/1.05 1,25/1,4/1,45
Voltage protection level Ures at 5 kA [kV] 0.85/1.4/0.95 0.85/1.4/0.95 0.85/1.4/0.95 1.05/1.4/1.1 1,35/1,4/1,55
Voltage protection level Ures at 10 kA [kV] 1/1.4/1.15 1/1.4/1.15 1/1.4/1.15 1.2/1.4/1.3 1,55/1,4/1,65
TOV (Temporary overvoltage) withstand [V] 337/1200 337/1200 337/1200 455/1200 581/1200
Ut (L-N: 5s./N-PE: 200ms)
Uoc [kV] - - - - -
Response time [ns] < 25 < 25 < 25 < 25 <25
Short-circuit withstand capability Isccr [kA] 100 100 100 100 100
Backup protection fuse (gG) [A] ≤ 125 ≤ 160 ≤ 160 ≤ 125 ≤ 125
maximum rating
circuit breaker [A] ≤ 125 ≤ 125 ≤ 125 ≤ 125 ≤ 125
(B or C curve)
Pluggable cartridge Yes Yes Yes Yes Yes
Integrated QuickSafe® technology Yes Yes Yes Yes Yes
State indicator Yes Yes Yes Yes Yes
Safety reserve No Yes Yes No No
Auxiliary contact Yes (TS option) Yes (TS option) Yes (TS option) Yes (TS option) Yes
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 … 35 2.5 … 35 2.5 … 35 2.5 … 35 2.5 … 35
stranded wire [mm²] 2.5 … 25 2.5 … 25 2.5 … 25 2.5 … 25 2.5 … 25
Stripping length (L, N, PE) [mm] 12.5 12.5 12.5 12.5 12.5
Tightening torque (L, N, PE) [Nm] 2.8 2.8 2.8 2.8 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Min. load 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA
Max. load 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A
Connection cross-section [mm²] 1.5 1.5 1.5 1.5 1.5
Miscellanous characteristics
Stocking and operating temperature °C -40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80
Maximal Altitude [m] 5000 5000 5000 5000 5000
Degree of protection IP 20 IP 20 IP 20 IP 20 IP 20
Fire resistance according to UL 94 V0 V-0 V-0 V0 V0
5/51
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS/TT
230 and 400 V 1Ph+N networks
Technical features
Types OVR T2 1N OVR T2 1N OVR T2 1N OVR T2 1N
40-275 P QS 40-275s P QS 80-275s P QS 40-350 P QS
5
with auxiliary contact (TS) OVR T2 1N 40- OVR T2 1N 40- OVR T2 1N 80- OVR T2 1N 40- OVR T2 1N 40-
275 P TS QS 275s P TS QS 275s P TS QS 350 P TS QS 440 P TS QS
Dimensions
height x width x depth mm 88 x 35.6 x 65.3 88 x 35.6 x 76.7 88 x 35.6 x 76.7 88 x 35.6 x 65.3
inches 3.46 x 1.4 x 2.57 3.46 x 1.4 x 3.02 3.46 x 1.4 x 3.02 3.46 x 1.4 x 2.57
With Auxiliary Contact (TS)
height x width x depth mm 95.8 x 35.6 x 65.3 95.8 x 35.6 x 76.7 95.8 x 35.6 x 76.7 95.8 x 35.6 x 65.3 95.8 x 35.6 x 65.3
inches 3.77 x 1.4 x 2.57 3.77 x 1.4 x 3.02 3.77 x 1.4 x 3.02 3.77 x 1.4 x 2.57 3.77 x 1.4 x 2.57
Replacement Cartridges
Phase Product ID OVR T2 40-275 C OVR T2 40-275s C OVR T2 80-275s C OVR T2 40-350 C OVR T2 40-440 C
QS QS QS QS QS
2CTB803876R1000 2CTB815704R2600 2CTB815708R2600 2CTB803886R1000 2CTB803876R0400
Neutral Product ID OVR T2-T3 N 80- OVR T2 N 80-275s OVR T2 N 80-275s OVR T2 N 80-350 OVR T2 N 80-440
275 C QS C QS C QS C QS C QS
2CTB803876R0000 2CTB815708R2800 2CTB815708R2800 2CTB803886R0000 2CTB803886R0100
Type 2 surge protective devices are designed to protect electric installations and sensitive equipment
against indirect surges with ensuring a low protection level (Up).
They are characterized by their capacity to safely discharge current with 8/20 µs wave form.
Type 2 pluggable
Po Impluse Max Nomi- Voltage Nomi- Max. Bbn Order details Weight
les Curent dis- nal protec- nal cont. 3660308 1 piece
Iimp charge current tion voltage oper-
10/350 current In level Un ating
OVR T2 1N 40-
Imax Up voltage
275 P QS
8/20 Uc
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS/TT
230 and 400 V 3Ph+N networks
Technical features
Types OVR T2 3N 40-275 P QS OVR T2 3N 40-275s P QS
with auxiliary contact (TS) OVR T2 3N 40-275 P TS QS OVR T2 3N 40-275s P TS QS
5
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS/TT
230 and 400 V 3Ph+N networks
5
Varistor + GDT Varistor + GDT Varistor + GDT Varistor + GDT Varistor + GDT
IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
T2/II T2/II T2/II T2/II T2/II
3+1 3+1 3+1 3+1 3+1
TT - TNS TT - TNS TT - TNS TT - TNS TT - TNS
AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
± 20 % ± 50 % ± 10% ± 10% ± 10%
230/440 230/400 400/690 400/690 400/690
275/440 350/600 440/760 440/760 440/760
80 40 40 40 80
6.25 2 2 2 6.25
20 20 20 20 20
80 80 80 80 80
1.4/1.4/1.5 1.5/1.4/1.7 1.8/1.4/2.1 1.8/2/2.1 1.8/2/2.1
0.8/1.4/0.85 1.0/1.4/1.05 1.25/1.4/1.45 1.25/1.4/1.45 1.25/1.4/1.45
1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA 12 DC - 10 mA
250 V AC - 1A 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A 250 V AC - 1A
1.5 1.5 1.5 1.5 1.5
-40 to +80 -40 to +80 -40 to +80 -40 to +80 -40 to +80
5000 5000 5000 5000 5000
IP 20 IP 20 IP 20 IP 20 IP 20
V-0 V0 V0 V-0 V-0
95.8 x 71.2 x 76.7 95.8 x 71.2 x 65.3 95.8 x 71.2 x 65.3 95.8 x 71.2 x 76.7 95.8 x 71.2 x 76.7
3.77 x 2.8 x 3.02 3.77 x 2.8 x 2.57 3.77 x 2.8 x 2.57 3.77 x 2.8 x 3.02 3.77 x 2.8 x 3.02
OVR T2 80-275s C QS OVR T2 40-350 C QS OVR T2 40-440 C QS OVR T2 40-440s C QS OVR T2 80-440s C QS
2CTB815708R2600 2CTB803886R1000 2CTB803876R0400 2CTB815704R5500 2CTB815708R5500
OVR T2 N 80-275s C QS OVR T2 N 80-350 C QS OVR T2-T3 N 80-440 C QS OVR T2 N 80-440s C QS OVR T2 N 80-440s C QS
2CTB815708R2800 2CTB803886R0000 2CTB803886R0100 2CTB815708R5700 2CTB815708R5700
5/54 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 pluggable QuickSafe® surge protective devices TNS/TT
230 and 400 V 3Ph+N networks
Type 2 surge protective devices are designed to protect electric installations and sensitive equipment
against indirect surges with ensuring a low protection level (Up). They are characterized by their
capacity to safely discharge current with 8/20 µs wave form.
5
Type 2 pluggable
Pro- Max Nomi- Volt- Nominal Max. Bbn Order details Weight
tected dis- nal dis- age voltage cont. 3660308 1 piece
OVR T2 3N 40-
lines charge charge pro- Un oper-
275 P QS
current current tec- ating
Imax In tion volt-
8/20 level age
Up Uc
—
Notes
5
5/56 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type T2-T3 pluggable QuickSafe® surge protective devices
Single pole - 230 V and 440 V networks
Technical features
Types OVR T2-T3 20- OVR T2-T3 20- OVR T2-T3 N OVR T2-T3 N
275 P QS 440 P QS 80-275 P QS 80-440 P QS
5
with auxiliary contact (TS) OVR T2-T3 20- OVR T2-T3 20- - -
275 P TS QS 440 P TS QS
Technology Varistor Varistor GDT GDT
Electrical features
Standard IEC 61643-11/ IEC 61643-11/ IEC 61643-11/ IEC 61643-11/
EN 61643-11 EN 61643-11 EN 61643-11 EN 61643-11
Type/test class T2-T3/II-III T2-T3/II-III T2-T3/II-III T2-T3/II-III
Protected lines 1 1 1 1
System network TNC - TT(L-N) - TNS TNC - TT(L-N) - TNS TT (N-PE)-TNS(N-PE) TT (N-PE)-TNS(N-PE)
Type of current AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ± 20 % ± 10% ± 20 % ± 10 %
Nominal system voltage Un [V] 230 400 230 400
Max. cont. operating voltage Uc [V] 275 440 275 440
Nominal dc voltage Un dc L-PE [V dc] 320 320 - -
Max. dc. cont. operating voltage Ucdc L-PE [V dc] 355 355 - -
Maximum discharge current Imax (8/20) [kA] 20 20 80 80
Nominal discharge current In (8/20) [kA] 5 5 2 2
Voltage protection level Up at In (L-N) [kV] 0.9/-/- 1.4/-/- 30 30
Voltage protection level Ures at 3kA (L-N) [kV] 0.8 1.25 -/-/1.4 -/-/1.4
Voltage protection level Ures at 5kA (L-N) [kV] 0.85 1.35 - -
Voltage protection level Ures at 10kA (L-N) [kV] 1 1.55 - -
TOV (Temporary overvoltage) withstand Ut [V] 337/- 581/- - -
(L-N: 5s./N-PE: 200ms)
Uoc [kV] 6 6 - -
Response time [ns] ≤ 25 ≤ 25 -/1200 -/1200
Short-circuit withstand capability Isccr [kA] 100 100 <25 <25
Backup protection fuse (gG) [A] ≤ 125 ≤ 125 <125 <125
maximum rating circuit breaker (B or C [A] ≤ 125 ≤ 125 <125 <125
curve)
Pluggable cartridge Yes Yes Yes Yes
Integrated QuickSafe® technology Yes Yes - -
State indicator Yes Yes No No
Safety reserve No No No No
Auxiliary contact Yes (TS option) Yes (TS option) No No
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 ... 35 2.5 ... 35 2.5 ... 35 2.5 ... 35
stranded wire [mm²] 2.5 ... 25 2.5 ... 25 2.5 ... 25 2.5 ... 25
Stripping length (L, N, PE) [mm] 12.5 12.5 12.5 12.5
Tightening torque (L, N, PE) [Nm] 2.8 2.8 2.8 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC 1 NO - 1 NC - -
Min. load 12 DC - 10 mA 12 DC - 10 mA - -
Max. load 250 V AC - 1A 250 V AC - 1A - -
Connection cross-section [mm²] 1.5 1.5 - -
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80 -40 to +80 -40 to + 80 -40 to + 80
Maximal Altitude [m] 5000 5000 5000 5000
Degree of protection IP 20 IP 20 IP 20 - Indoor IP 20 - Indoor
Fire resistance according to UL 94 V0 V0 V-0 V-0
Dimensions of packing
height x width x depth [mm] 88 x 17.8 x 65.3 88 x 17.8 x 65.3 85 x 17.8 x 64.8 85 x 17.8 x 64.8
[inches] 3.46 x 0.7 x 2.57 3.46 x 0.7 x 2.57 3.35 x 0.70 x 2.55 3.35 x 0.70 x 2.55
5/57
—
Protection and safety
OVR Type T2-T3 pluggable QuickSafe® surge protective devices
Single pole - 230 V and 440 V networks
Technical features
Types OVR T2-T3 20- OVR T2-T3 20- OVR T2-T3 N OVR T2-T3 N
275 P QS 440 P QS 80-275 P QS 80-440 P QS
5
with auxiliary contact (TS) OVR T2-T3 20- OVR T2-T3 20- - -
275 P TS QS 440 P TS QS
With Auxiliary Contact (TS)
height x width x depth [mm] 95.8 x 17.8 x 65.3 95.8 x 17.8 x 65.3 - -
[inches] 3.77 x 0.7 x 2.57 3.77 x 0.7 x 2.57 - -
Replacement Cartridges
Phase Product ID OVR T2-T3 20-275 C OVR T2-T3 20-440 C OVR T2-T3 N 80-275 OVR T2-T3 N 80-275
QS QS C QS C QS
2CTB803876R1200 2CTB803876R0600 2CTB803876R0000 2CTB803876R0000
Neutral Product ID - - - -
Type 2 and 3 surge protective devices shall be installed as close as possible to the sensitive equipment
to protect. As Type 2 they have been characterize by their capacity to safely discharge current with
a 8/20 µs wave form and they guarantee the coordination with Type 1 SPDs or other Type 2 respecting
coordination distances. As Type 3 they are characterized by their capacity to safely discharge current
with 1.2/50 µs wave form, with a very low level of Voltage Protection level.
Poles Max Nomi- Voltage Nomi- Max. Bbn Order details Weight
dis- nal dis- protec- nal cont. 3660308 1 piece
OVR T2 T3 20- 275 P QS charge charge tion voltage oper-
current current level Un ating
Imax In Up volt-
8/20 age
Uc
—
Protection and safety
OVR Type T2-T3 pluggable QuickSafe® surge protective devices
TNC - 230 V 3Ph + N networks
Technical features
Types OVR T2-T3 3L 20-275 P QS
with auxiliary contact (TS) OVR T2-T3 3L 20-275 P TS QS
5
Technology Varistor
Electrical features
Standard IEC 61643-11/EN 61643-11 / UL 1449 4th Ed
Type/test class T2-T3/II-III
Protected lines 3
System network TNC
Type of current AC 47-63 Hz
Voltage regulation of the system network ± 20 %
Nominal system voltage Un (L-PE/L-L) [V] 230/400
Max. cont. operating voltage Uc (L-PE/L-L) [V] 275/440
Nominal dc voltage Un dc L-PE [V dc] 320
Max. dc. cont. operating voltage Ucdc L-PE [V dc] 355
Maximum discharge current Imax (8/20) [kA] 20
Nominal discharge current In (8/20) [kA] 5
Total Current [kA] 60
Voltage protection level Up at In (L-N/N-PE /L-PE) [kV] 0,85/-/-
Voltage protection level Ures at 3kA [kV] 0.8
Voltage protection level Ures at 5kA [kV] 0.85
Voltage protection level Ures at 10kA [kV] 1.0
TOV (Temporary overvoltage) withstand Ut (L-N: 5s./N-PE: [V] 337/-
200ms)
Uoc [kV] 6
Response time [ns] ≤ 25
Short-circuit withstand capability Isccr [kA] 100
Backup protection maximum fuse (gG) [A] ≤ 125
rating circuit breaker (B or C curve) [A] ≤ 125
Pluggable cartridge Yes
Integrated QuickSafe® technology Yes
State indicator Yes
Safety reserve No
Auxiliary contact Yes (TS option)
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 ... 35
stranded wire [mm²] 2.5 ... 25
Stripping length (L, N, PE) [mm] 12.5
Tightening torque (L, N, PE) [Nm] 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC
Min. load 12 DC - 10 mA
Max. load 250 V AC - 1A
Connection cross-section [mm²] 1.5
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80
Maximal Altitude [m] 5000
Degree of protection IP 20
Fire resistance according to UL 94 V0
Dimensions
height x width x depth mm 88 x 53.4 x 65.3
inches 3.46 x 2.1 x 2.57
5/59
—
Protection and safety
OVR Type T2-T3 pluggable QuickSafe® surge protective devices
TNC - 230 V 3Ph + N networks
Technical features
Types OVR T2-T3 3L 20-275 P QS
with auxiliary contact (TS) OVR T2-T3 3L 20-275 P TS QS
5
With Auxiliary Contact (TS)
height x width x depth mm 95.8 x 53.4 x 65.3
inches 3.77 x 2.1 x 2.57
Replacement Cartridges
Phase Product ID OVR T2-T3 20-275 C QS
2CTB803876R1200
Neutral Product ID -
Type 2 and 3 surge protective devices shall be installed as close as possible to the sensitive
equipment to protect. As Type 2 they have been characterize by their capacity to safely
discharge current with a 8/20 µs wave form and they guarantee the coordination with Type 1
SPDs or other Type 2 respecting coordination distances. As Type 3 they are characterized by
their capacity to safely discharge current with 1.2/50 µs wave form, with a very low level of
Voltage Protection level.
Po Max Nomi- Volt- Nomi- Max. Bbn Order details Weight
OVR T2 T3 3L 20-275 P TS QS les dis- nal dis- age nal cont. 3660308 1 piece
charge charge pro- voltage oper-
current current tec- Un ating
Imax In tion volt-
8/20 level age
Up Uc
—
Protection and safety
OVR Type T2-T3 QuickSafe® surge protective devices
TNS/TT - 230 V 1Ph+N networks
Technical features
Types OVR T2-T3 1N 20-275 P QS
with auxiliary contact (TS) OVR T2-T3 1N 20-275 P TS QS
5
Electrical features
Standard IEC 61643-11/EN 61643-11
Type/test class T2-T3/II-III
Protected lines 1+1
System network TT - TNS
Type of current AC 47-63 Hz
Voltage regulation of the system network ± 20 %
Nominal system voltage Un [V] 230
Max. cont. operating voltage Uc [V] 275
Maximum discharge current Imax (8/20) [kA] 20
Nominal discharge current In (8/20) [kA] 5
Total Current [kA] 40
Voltage protection level Up at In (L-N/N-PE/L-PE) [kV] 0.9/1.4/1.4
Voltage protection level Ures at 3kA (L-N/N-PE /L-PE) [kV] 0.8/1.4/0.85
Voltage protection level Ures at 5kA(L-N/N-PE /L-PE) [kV] 0.85/1.4/0.95
Voltage protection level Ures at 10kA (L-N/N-PE /L-PE) [kV] 1/1.4/1.15
TOV (Temporary overvoltage) withstand Ut (L-N: 5s./N-PE: [V] 337/1200
200ms)
Uoc [kV] 6
Response time [ns] ≤ 25
Residual current IPE [µA] ≤ 10
Short-circuit withstand capability Isccr [kA] 100
Backup protection maximum fuse (gG) [A] ≤ 125
rating circuit breaker (B or C curve) [A] ≤ 125
Pluggable cartridge Yes
Integrated QuickSafe® technology Yes
State indicator Yes
Safety reserve No
Auxiliary contact Yes (TS option)
Installation
Wire range (L, N, PE) solid wire [mm²] 2.5 ... 35
stranded wire [mm²] 2.5 ... 25
Stripping length (L, N, PE) [mm] 12.5
Tightening torque (L, N, PE) [Nm] 2.8
Auxiliary contact (TS)
Contacts information 1 NO - 1 NC
Min. load 12 DC - 10 mA
Max. load 250 V AC - 1A
Connection cross-section [mm²] 1.5
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80
Maximal Altitude [m] 5000
Degree of protection IP 20
Fire resistance according to UL 94 V0
5/61
—
Protection and safety
OVR Type T2-T3 QuickSafe® surge protective devices
TNS/TT - 230 V 1Ph+N networks
Technical features
Types OVR T2-T3 1N 20-275 P QS
with auxiliary contact (TS) OVR T2-T3 1N 20-275 P TS QS
5
Dimensions
height x width x depth [mm] 88 x 35.6 x 65.3
[inches] 3.46 x 1.4 x 2.57
With Auxiliary Contact (TS)
height x width x depth mm 95.8 x 35.6 x 65.3
inches 3.77 x 1.4 x 2.57
Replacement Cartridges
Phase Product ID OVR T2-T3 20-275 C QS
2CTB803876R1200
Neutral Product ID OVR T2-T3 N 80-275 C QS
2CTB803876R0000
Type 2 and 3 surge protective devices shall be installed as close as possible to the sensitive
equipment to protect. As Type 2 they have been characterize by their capacity to safely
discharge current with a 8/20 µs wave form and they guarantee the coordination with Type 1
SPDs or other Type 2 respecting coordination distances. As Type 3 they are characterized by
their capacity to safely discharge current with 1.2/50 µs wave form, with a very low level of
Voltage Protection level.
Po Max Nomi- Volt- Nomi- Max. Bbn Order details Weight
OVR T2 T3 1N 20-275 P QS
les dis- nal dis- age nal cont. 3660308 1 piece
charge charge pro- voltage oper-
current current tec- Un ating
Imax In tion volt-
8/20 level age
Up Uc
—
Protection and safety
OVR Type T2-T3 QuickSafe® surge protective devices
TT - 230 V and 400 V 3Ph+N networks
Technical features
Types OVR T2-T3 3N 20-275 P QS OVR T2-T3 3N 20-440 P QS
with auxiliary contact (TS) OVR T2-T3 3N 20-275 P TS QS
5
—
Protection and safety
OVR Type T2-T3 QuickSafe® surge protective devices
TT - 230 V and 400 V 3Ph+N networks
Technical features
Types OVR T2-T3 3N 20-275 P QS OVR T2-T3 3N 20-440 P QS
with auxiliary contact (TS) OVR T2-T3 3N 20-275 P TS QS
5
Dimensions
height x width x depth mm 88 x 71.2 x 65.3 88 x 71.2 x 65.3
inches 3.46 x 2.8 x 2.57 3.46 x 2.8 x 2.57
With Auxiliary Contact (TS)
height x width x depth mm 95.8 x 71.2 x 65.3 96 x 71.2 x 64.8
inches 3.77 x 2.8 x 2.57 3.35 x 2.81 x 2.55
Replacement Cartridges
Phase Product ID OVR T2-T3 20-275 C QS OVR T2-T3 20-440 C QS
2CTB803876R1200 2CTB803876R0600
Neutral Product ID OVR T2-T3 N 80-275 C QS OVR T2-T3 N 80-440 C QS
2CTB803876R0000 2CTB803886R0100
Type 2 and 3 surge protective devices shall be installed as close as possible to the sensitive
equipment to protect. As Type 2 they have been characterize by their capacity to safely
discharge current with a 8/20 µs wave form and they guarantee the coordination with Type 1
SPDs or other Type 2 respecting coordination distances. As Type 3 they are characterized by
their capacity to safely discharge current with 1.2/50 µs wave form, with a very low level of
Voltage Protection level.
OVR T2 T3 3N 20-275 P TS QS Po Max Nomi- Volt- Nomi- Max. Bbn Order details Weight
les dis- nal dis- age nal cont. 3660308 1 piece
charge charge pro- voltage oper-
current current tec- Un ating
Imax In tion volt-
8/20 level age
Up Uc
—
Protection and safety
OVR Type T2-T3 StreetLight surge protective devices TT/TN - 230 V 1Ph+N networks
Technical features
Types OVR T2-T3 N1 15-275S SL
Technology Varistor + GDT
5
Electrical features
Standard IEC 61643-11/EN 61643-11
Type/test class T2-T3/II-III
System network TT, TNS
Protection mode Common/Differential
Number of pole/Type of current 1+1
Nominal system voltage Un [V] 230
Max. cont. operating voltage Uc (L-N ) [V] 275
Maximum discharge current Imax (8/20) [kA] 15
Nominal discharge current In (8/20) [kA] 5
Total Current [kA] 30
Voltage protection level Up at In (L-N/L-PE) [kV] 1.1/1.3
TOV (Temporary overvoltage) withstand Ut (L-N: 5s.) [V] 337
Uoc [kV] 1.1
Response time [ns] < 25
Short circuit withstand Icc [kA] 15
Backup protection maximum fuse (gG) [A] < 20 A
rating circuit breaker (B or C curve) [A] < 20 A
Pluggable cartridge No
Integrated QuickSafe® technology No
State indicator Yes
Safety reserve Yes
Installation
Wire range : phase and neutral wire 2 x 1.5 mm² - L 16 cm
Wire range : Protective Earth wire [mm²] < 6 mm²
Stripping length (L, N, PE) [mm] 10
Auxiliary contact (TS)
Contacts information -
Min. load -
Max. load -
Connection cross-section [mm²] -
Miscellanous characteristics
Stocking and operating temperature [°C] -40 to +80
Degree of protection IP 32
Fire resistance according to UL 94 V0
Dimensions
height x width x depth [mm] 80 x 17.5 x 41
[inches] 3.15 x 0.69 x 1.62
With Auxiliary Contact (TS)
height x width x depth [mm] -
[inches] -
5/65
—
Protection and safety
OVR Type T2-T3 StreetLight surge protective devices TT/TN - 230 V 1Ph+N networks
5
It has the Safety system integrated by default, performed by two varistors in parallel,
allowing the customer to perform preventive maintenance. As soon as one of the Life status
windows swap from green to red, we know the product needs to be replaced, but it still
guarantees the protection.
It has IP 32 and bottom connections to guarantee the best performances in critical and
OVR T2 T3 StreetLight
humid environment.
Po Max Nomi- Volt- Nomi- Max. Bbn Order details Weight
les dis- nal dis- age nal cont. 3660308 1 piece
charge charge pro- voltage oper-
current current tec- Un ating
Imax In tion volt-
8/20 level age
Up Uc
—
Protection and safety
OVR Plus - Autoprotected surge protective devices TNS/TT 230 V networks
Technical features
Types OVR Plus N1 20 OVR Plus N1 40 OVR Plus N3 20 OVR Plus N3 40
with auxiliary contact (TS) – – – –
5
—
Protection and safety
OVR Plus - Autoprotected surge protective devices TNS/TT 230 V networks
OVR PLUS N3 20 and OVR PLUS N3 40 for commercial and industrial applications:
• Auto-protected: Backup miniature circuit breaker integrated and fully coordinated with the
surge protective device.
5
• Easy installation: Fully coordinated unit with easy wiring with the complete ABB pro M
modular range.
• High discharge capacity: With Imax 20 and 40 kA the OVR Plus N3 insure the protection of
OVR PLUS N3 20 your low
OVR PLUS N3 40
voltage installations and electric equipment.
• High reliability: No welding inside the module and specific thermal disconnection with the
„bilame“ sensor.
Type 2 autoprotected
Po Max Nomi- Volt- Nomi- Max. Bbn Order details Weight
les dis- nal dis- age nal cont. 3660308 1 piece
charge charge pro- voltage oper-
current current tec- Un ating
Imax In tion volt-
8/20 level age
Up Uc
—
Protection and safety
OVR PV surge protective devices Photovoltaic networks
Technical features
Types OVR PV T2 40- OVR PV T2 40- OVR PV T2 40-
600 P QS 1000 P QS 1500 P QS
5
with auxiliary contact (TS) OVR PV T2 40- OVR PV T2 40- OVR PV T2 40-1000 OVR PV T2 40-
600 P TS QS 1000 P TS QS P TS TWIN QS 1500 P TS QS
Technology Varistor Varistor Varistor Varistor
Electrical features
Standard IEC 61643-11/ IEC 61643-11/ IEC 61643-11/ IEC 61643-11/
EN 61643-11/ EN 61643-11/ EN 61643-11/ EN 61643-11/
UL 1449 4th Ed UL 1449 4th Ed UL 1449 4th Ed UL 1449 4th Ed
Type/test class T2/II T2/II T2/II T2/II
Protected lines 2 2 4 2
Types of networks Photovoltaic Photovoltaic Photovoltaic Photovoltaic
Type of current DC DC DC DC
Nominal voltage Un (L-N/L-L) [V] 600 1000 1000 1500
Max. cont. operating voltage Ucpv [V] 600 1100 1100 1500
Max.cont.operating voltage [V] 600 1100 1100 1500
according (MCOV)
Impulse current Iimp (10/350) 2 - 2 2
Maximum discharge current [kA] 40 40 40 40
Imax (8/20)
Nominal discharge current In (8/20) [kA] 20 20 20 10
Voltage protection level Up at In [kV] 2.8/1.4 3.8/3.8 3.8/3.8 4.5/4.5
(L-L/L-PE)
Voltage protection rating according [kV] 1.2/1.2/1.8 2.5/2.5/2.5 2.5/2.5/2.5 4/4/4
(VPR (L+/G, L-/G, L+/L-))
Response time [ns] ≤ 25 ≤ 25 ≤ 25 ≤ 25
Residual current IPE [µA] ≤10 ≤1000 ≤1000 ≤1000
Short-circuit DC current Iscpv [A] 300 10,000 10,000 10,000
Short circuit withstand [kA] 10 10 10 10
according (SCCR)
Disconnector Fuse no need up to 0.3 kA no need up to 10 kA no need up to 10 kA no need up to 10 kA
Circuit breaker no need up to 0.3 kA no need up to 10 kA no need up to 10 kA no need up to 10 kA
Pluggable cartridge Yes Yes Yes Yes
Integrated specific thermal Yes Yes Yes Yes
disconnector
State indicator Yes Yes Yes Yes
Safety reserve No No No No
Auxiliary contact Yes (TS option) Yes (TS option) Yes (TS option) Yes (TS option)
Installation
Wire range Solid wire [mm²] 2.5…35 2.5…35 2.5…35 2.5…35
(L, N, PE) Stranded wire [mm²] 2.5…25 2.5…25 2.5…25 2.5…25
Stripping length (L, N, PE) 12.2 12.2 12.2 12.2
Tightening torque (L, N, PE) 2.5 2.5 2.5 2.5
Auxiliary contact (TS)
Contact complement 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Minimum load 12 V DC - 10 mA 12 V DC - 10 mA 12 V DC - 10 mA 12 DC - 10 mA
Maximum load 250 V AC - 1 A 250 V AC - 1 A 250 V AC - 1 A 250 V AC - 1A
Connection cross-section 1.5 1.5 1.5 1.5
Miscellaneous characteristics
Stocking and operating temperature [°C] -40 to +80 -40 to +80 -40 to +80 -40 to +80
Maximal Altitude [m] 5000 5000 5000 5000
Humidity Rate HR 95% 95% 95% 95%
Degree of protection IP20 IP20 IP20 IP 20
Fire resistance according to UL 94 V0 V0 V0 V0
Dimensions height x width x [mm] 88 x 53.4 x 65 88 x 53.4 x 65 88 x 88,33 x 65 88 x 53.4 x 65
depth [inches] 3.46 x 2.10 x 2.56 3.46 x 2.10 x 2.56 3.46 x 3,5 x 2.56 3.46 x 2.10 x 2.56
with auxiliary height x width x [mm] 95 x 53.4 x 65 95 x 53.4 x 65 95 x 88,33 x 65 95 x 53.4 x 65
contact (TS) depth [inches] 3.46 x 2.10 x 2.56 3.77 x 2.1 x 2.55 3.46 x 3,5 x 2.56 3.46 x 2.10 x 2.56
Replacement Cartridges
Phase Product ID OVR PV T2 40-600 C QS OVR PV T2 40-1000 C QS OVR PV T2 40-1000 C QS OVR PV T2 40-1500 C QS
2CTB804153R3100 2CTB804153R3200 2CTB804153R3200 2CTB804153R3300
OVR PV MC C QS
2CTB804153R3500
5/69
Technical features
Types OVR PV T1-T2 5- OVR PV T1-T2 OVR PV T1-T2 5- OVR PV T1-T2 10-
1000 P QS 12.5-1000 P QS 1500 P QS 1500 P QS
5
With auxiliary contact (TS) OVR PV T1-T2 OVR PV T1-T2 12.5- OVR PV T1-T2 OVR PV T1-T2 10-
5-1000 P TS QS 1000 P TS QS 5-1500 P TS QS 1500 P TS QS
Technology Varistor Varistor Varistor Varistor
Electrical features
Standard IEC61643-11/ IEC61643-11/ IEC61643-11/ IEC61643-11/
IEC 61643-31/ IEC 61643-31/ IEC 61643-31/ IEC 61643-31/
UL 1449 4th Ed. UL 1449 4th Ed.
Type/test class T1-T2/I-II T1-T2/I-II T1-T2/I-II T1-T2/I-II
Protected lines 2 2 2 2
Types of networks Photovoltaic Photovoltaic Photovoltaic Photovoltaic
Type of current DC DC DC DC
Nominal Voltage Un (L-N)/L-L) [V] 1000 1000 1500 1500
Max. cont. Operating voltage Ucpv [V] 1100 1100 1500 1500
Max.cont.operating voltage accroding 1100 1100 1500 1500
UL (MCOV)
Impulse current Iimp (10/350) [kA] 5 6.26 5 5
Total discharge current Itotal (10/350) [kA] 5 12.5 5 10
Maximum discharge current Imax (8/20) [kA] 40 40 30 30
Nominal discharge current In (8/20) [kA] 20 20 20 20
Voltage protection level Up at In (L-L/L-N) [kV] 3,8 3.8 5 5
Voltage protection rating according [kV] 3,8 2.5/2.5/2.5 - 4/4/4
UL (VPR (L+/G, L-/G, L+/L-))
Response time [ns] <25 <25 <25 <25
Short circuit DC current Iscpv [A] 11 11 11 11
Short circuit withstand according (Logo UL) (Sccr) [kA] - 50 - 65
Disconnector Fuse no need up to 11 kA no need up to 11 kA no need up to 11 kA no need up to 11 kA
Circuit breaker no need up to 11 kA no need up to 11 kA no need up to 11 kA no need up to 11 kA
Pluggable cartridge Yes Yes Yes Yes
Integrated specific thermal disconnector Yes Yes Yes Yes
State indicator Yes Yes Yes Yes
Safety Reserve No No No No
Auxiliary contact Yes (TS option) Yes (TS option) Yes (TS option) Yes (TS option)
Installation
Wire range Solid wire [mm²] 2.5….35 2.5….35 2.5….35 2.5….35
(L, N, PE) Stranded wire [mm²] 2.5…25 2.5…25 2.5…25 2.5…25
Stripping length (L,N,PE) [mm²] 12.5 12.5 12.5 12.5
Tightening torque (L, N, PE) [N.m] 4.5 4.5 4.5 4.5
Auxiliary contact (TS)
Contact complement 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC 1 NO - 1 NC
Minimum load 12 V DC - 0,5 mA 12 V DC - 0,5 mA 12 V DC - 0,5 mA 12 V DC - 0,5 mA
Maximum load 250 V AC - 1 A 250 V AC - 1 A 250 V AC - 1 A 250 V AC - 1 A
Connection cross-section 1.5 1.5 1.5 1.5
Miscellaneous characteristics
Stocking and operating temperature [°C] -40 to +85 -40 to +85 -40 to +85 -40 to +85
Maximal Altitude [m] 4000 4000 4000 4000
Humidity Rate HR 95% 95% 95% 95%
Degree of protection IP 20 IP 20 IP 20 IP 20
Fire resistance according to UL 94 V0 V0 V0 V0
Dimensions height x width [mm] 95 x 54 x 86 95 x 54 x 86 95 x 54 x 86 95 x 54 x 86
depth [inches] 3.74 x 2.12 x 3.38 3.74 x 2.12 x 3.38 3.74 x 2.12 x 3.38 3.74 x 2.12 x 3.38
With auxiliary height x width [mm] 110 x 54 x 86 110 x 54 x 86 110 x 54 x 86 110 x 54 x 86
contact (TS) depth [inches] 4.33 x 2.12 x 3.38 4.33 x 2.12 x 3.38 4.33 x 2.12 x 3.38 4.33 x 2.12 x 3.38
Replacement cartridges
Phase Product ID OVR PV T1-T2 5- OVR PV T1-T2 12.5- OVR PV T1-T2 5- OVR PV T1-T2 10-
1000 C QS 1000 C QS 1500 C QS 1500 C QS
2CTB812052R1000 2CTB812122R1000 2CTB812052R1500 2CTB812102R1500
OVR PV T1-T2 12.5- OVR PV T1-T2 10-
- 1000 M C QS - 1500 M C QS
2CTB812122R1001 2CTB812102R1501
5/70 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR PV surge protective devices Photovoltaic networks
Specifically designed for photovoltaic DC installations, the OVR PV family provide a safe and reliable surge and lightning
protection of solar panels and converters.
The OVR PV QS surge protective devices comply with EN 50539-11 and UL 1449 4th Edition.
5
Type T1+T2 PV
Pro- Impulse Total Max. Nominal Voltage Max. Bbn Order details Weight
tected current disch. dischar. current protec- cont. 3660308 1 piece
lines Iimp current current In tion operat-
10/350 Itotal Imax level ing volt-
10/350 8/20 Up age
Ucpv
kA kA kA kA kV V EAN Type code Order code kg
1+1 DC 2 - 40 20 2.8/1.4 600 526502 OVR PV T2 40-600 P QS 2CTB804153R2800 0.38
1+1 DC 2 - 40 20 2.8/1.4 600 526519 OVR PV T2 40-600 P TS QS 2CTB804153R2900 0.39
1+1 DC 2 - 40 20 2.8/1.4 600 527318 OVR PV T2 40-600 P QS BULK (30) 2CTB804153Z2800 0.38
1+1 DC 2 - 40 20 2.8/1.4 600 527325 OVR PV T2 40-600 P TS QS BULK (30) 2CTB804153Z2900 0.39
1+1 DC - - 40 20 3.8 1100 526243 OVR PV T2 40-1000 P QS 2CTB804153R2400 0.38
1+1 DC 2 - 40 20 3.8 1100 526434 OVR PV T2 40-1000 P TS QS 2CTB804153R2500 0.39
1+1 DC 2 - 40 20 3.8 1100 526748 OVR PV T2 40-1000 P QS BULK (30) 2CTB804153Z2400 0.36
1+1 DC 2 - 40 20 3.8 1100 526755 OVR PV T2 40-1000 P TS QS BULK (30) 2CTB804153Z2500 0.39
2+2 DC 2 - 40 20 3.8 1100 526199 OVR PV T2 40-1000 P TS TWIN QS 2CTB804153R2300 0.65
2+2 DC 2 - 40 20 3.8 1100 527295 OVR PV T2 40-1000 P TS TWIN QS 2CTB804153Z2300 0.65
BULK (4)
1+1 DC 5 5 40 20 3.8/3.8 1100 4,05E+12 OVR PV T1-T2 5-1000 P QS 2CTB812050R1000 0.397
1+1 DC 5 5 40 20 3.8/3.8 1100 4,05E+12 OVR PV T1-T2 5-1000 P TS QS 2CTB812051R1000 0.406
1+1 DC 6,25 12.5 40 20 3.8/3.8 1100 4,05E+12 OVR PV T1-T2 12.5-1000 P QS 2CTB812120R1000 0.453
1+1 DC 6,25 12.5 40 20 3.8/3.8 1100 4,05E+12 OVR PV T1-T2 12.5-1000 P TS QS 2CTB812121R1000 0.462
1+1 DC 5 5 30 20 5/5 1500 4,05E+12 OVR PV T1-T2 5-1500 P QS 2CTB812050R1500 0.488
1+1 DC 5 5 30 20 5/5 1500 4,05E+12 OVR PV T1-T2 5-1500 P TS QS 2CTB812051R1500 0.497
1+1 DC 5 10 30 20 5/5 1500 4,05E+12 OVR PV T1-T2 10-1500 P QS 2CTB812100R1500 0.488
1+1 DC 5 10 30 20 5/5 1500 4,05E+12 OVR PV T1-T2 10-1500 P TS QS 2CTB812101R1500 0.497
1+1 DC 2 - 40 10 4.5 1500 526465 OVR PV T2 40-1500 P QS 2CTB804153R2600 0.47
1+1 DC 2 - 40 10 4.5 1100 526472 OVR PV T2 40-1500 P TS QS 2CTB804153R2700 0.48
1+1 DC 2 - 40 10 4.5 1500 527332 OVR PV T2 40-1500 P QS BULK (30) 2CTB804153Z2600 0.47
1+1 DC 2 - 40 10 4.5 1500 527301 OVR PV T2 40-1500 P TS QS BULK (30) 2CTB804153Z2700 0.48
—
Notes
5
5/72 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR WT surge protective devices - Wind turbine networks
Technical features
Types
with auxiliary contact (TS) OVR WT 3L 690 P TS OVR WT 3L 690
5
—
Protection and safety
OVR WT surge protective devices - Wind turbine networks
Due to their height, wind turbines have especially high exposure to lightning, they need high
capacity and reliable lightning and surge protection.
The OVR WT family takes into consideration the specificity of wind installations with
5
a high peak repetitive voltage withstand (Urp up to 3 kV) ensure a safe protection to Wind
applications.
It can be DIN mounted with the OVR.
OVR WT 3L 690 P TS
Type 1+2 WT
Pro- Impulse Max. Nomi- Volt- Max. Bbn Order details Weight
tected current dis- nal age cont. 1 piece
lines Iimp charge current pro- oper-
10/350 current In tec- ating
Imax tion volt-
8/20 level age
Up Ucpv
—
Protection and safety
Accessories for OVR
withstand to vibrations and shocks, it reinforces mechanical lock between the cartridges
and the socket (they are already locked by the pins in the back of the cartridge). It’s
recommended for stressful environments as the nazelle of the wind turbines. It’s sold on
Accessory for packs of 50.
Cartridge Lock
Bus bar
For TNC, IT, TNS or TT systems using single pole Type 1 SPDs assembled together, we have 2
Busbar
different bus bars than can be used, as listed here below.
These both products are sold in packs of 50.
—
Notes
5
5/76 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR surge protective devices – UL Version
Selection tables
Consult qualified personnel if the facility or operation ser- most transient surges are created internally, it is necessary
vice voltage is unknown. to install surge protection at sub-distribution panels (equip-
ment protection) to be fully protected. Stepping down the
2) Select the SPD maximum continuous operating voltage Imax level from the service entrance panel toward equip-
(MCOV, Uc) ment to be protected is recommended.
The MCOV should correspond to the service voltage. For example, if a 40 kA Imax SPD is installed in the main dis-
Example: If the service voltage is 480 V Delta, an SPD with tribution panel, then 15 kA Imax SPDs should be installed in
550 V or 660 V MCOV will be required. sub-distribution panels for equipment protection.
Surge protection devices must also provide a level of protec-
tion compatible with the withstand voltage of the equip- Coordination
ment. This withstand voltage depends on the type of equip- It may be necessary to add a second surge protector, wired
ment and its sensitivity. The incoming surge protector may to the incoming unit, to achieve the required voltage protec-
not provide adequate protection by itself, as certain electri- tion and/or surge capacity. For Type 2 or 4 SPDs, installing
cal phenomena may greatly increase its residual voltage if this second unit a minimum of 1 m from the first unit will al-
cable lengths exceed 10 m. A second SPD may be necessary. low the two to work together, achieving the required protec-
tion.
3) Select the SPD surge capacity (Imax)
Surge capacity is the amount of energy the SPD can with- Wiring rules
stand from a single surge event. The higher the surge capac- The impedance of the cables increases the voltage across
ity, the longer the device will protect the system. A second the connected equipment. Therefore, the length of the cable
surge protector may be required if the surge capacity of the between the surge protector and the equipment should be
first is not capable of diverting all surge current to ground. minimized.
See coordination below. The surge protective device should be installed as close to
the equipment to be protected as possible. If this is not pos-
4) Remote monitoring (Optional) sible (the equipment is over 30 m from the panel), then
Integrated auxiliary contact for remote monitoring available a second surge protector must be installed.
on models with "TS" designation. Consult "Selection tables"
on next page for help in the selection of SPDs.
Pro- Impulse Max. Nominal Follow Voltage Nominal Max. cont. Type Order code
tected current discharge discharge current protection voltage operating
lines current current interrupting Rating voltage
Iimp rating
10/350 Imax 8/20 In Ifi VPR Un MCOV
kA kA kA kA kV V V
Type 2 - Pluggable - Single Pole networks
1 – 15 5 – 0.6 120 150 OVR T2 15-150 P U 2CTB802341R0000
1 – 15 5 – 1 277 ±15% 320 OVR T2 15-320 P U 2CTB802341R0400
1 – 40 20 – 0.6 120 150 OVR T2 40-150 P U 2CTB802341R2000
1 – 40 20 – 0.6 120 150 OVR T2 40-150 P TS U 2CTB802341R2100
1 – 40 20 – 1 277 ±15% 320 OVR T2 40-320 P U 2CTB802341R2400
1 – 40 20 – 1 277 ±15% 320 OVR T2 40-320 P TS U 2CTB802341R2500
1 – 40 10 – 1.3 347 ±15% 440 OVR T2 40-440 P TS U 2CTB802341R2900
1 – 40 10 – 1.7 480 ±15% 550 OVR T2 40-550 P TS U 2CTB802341R3300
1 – 40 10 – 1.9 600 ±15% 660 OVR T2 40-660 P TS U 2CTB802341R3700
Neutral
1 – 70 20 0.1 1.2 230 275 OVR T2 70 N P U 2CTB802341R8000
Cartridges
1 – – – – – 120 ±15% 175 OVR T2 15-150 C U 2CTB802348R2500
1 – – – – – 277 ±15% 320 OVR T2 15-320 C U 2CTB802348R2700
1 – – – – – 120 ±15% 175 OVR T2 40-150 C U 2CTB802348R3500
1 – – – – – 277 ±15% 320 OVR T2 40-320 C U 2CTB802348R3700
1 – – – – – 347 ±15% 440 OVR T2 40-440 C U 2CTB802348R3900
1 – – – – – 480 ±15% 550 OVR T2 40-550 C U 2CTB802348R4100
1 – – – – – 600 ±15% 660 OVR T2 40-660 C U 2CTB802348R4300
1 – – – – – 230 275 OVR T2 70 N C U 2CTB802348R6500
5/7 7
—
Protection and safety
OVR surge protective devices – UL Version
Selection tables
Pro- Impulse Max. Nominal Follow Voltage Nominal Max. cont. Type Order code
tected current discharge discharge current protection voltage operating
lines current current interrupting Rating voltage
5
Iimp rating
10/350 Imax 8/20 In Ifi VPR Un MCOV
kA kA kA kA kV V V
Type 2 - Pluggable - Delta networks
3 – 15 5 – 1 277 +15% 320 OVR T2 3L 15-320 P U 2CTB802345R0400
3 – 40 20 – 1 277 ±15% 320 OVR T2 3L 40-320 P TS U 2CTB802345R2500
3 – 40 10 – 1.7 480 ±15% 550 OVR T2 3L 40-550 P TS U 2CTB802345R3300
Cartridges
1 – – – – – 277 ±15% 320 OVR T2 15-320 C U 2CTB802348R2700
1 – – – – – 277 ±15% 320 OVR T2 40-320 C U 2CTB802348R3700
1 – – – – – 480 ±15% 550 OVR T2 40-550 C U 2CTB802348R4100
Type 2 - Pluggable - Single Phase networks
2 – 15 5 – 1.2 120 150 OVR T2 1N 15-150 P U 2CTB802342R0000
2 – 15 5 – 1.2 277 320 OVR T2 1N 15-320 P U 2CTB802342R0400
2 – 40 20 – 1.2 120 150 OVR T2 1N 40-150 P U 2CTB802342R2000
2 – 40 20 – 1.2 120 150 OVR T2 1N 40-150 P U (x10) 2CTB802342R8000
2 – 40 20 – 1.2 120 150 OVR T2 1N 40-150 P TS U 2CTB802342R2100
2 – 40 20 – 1.2 277 320 OVR T2 1N 40-320 P TS U 2CTB802342R2500
2 – 40 10 – 1.2 347 440 OVR T2 1N 40-440 P TS U 2CTB802342R2900
2 – 40 10 – 1.2 480 550 OVR T2 1N 40-550 P TS U 2CTB802342R3300
2 – 40 10 – 1.2 600 660 OVR T2 1N 40-660 P TS U 2CTB802342R3700
Cartridges
1 – – – – – 120 ±15% 175 OVR T2 15-150 C U 2CTB802348R2500
1 – – – – – 277 ±15% 320 OVR T2 15-320 C U 2CTB802348R2700
1 – – – – – 120 ±15% 175 OVR T2 40-150 C U 2CTB802348R3500
1 – – – – – 277 ±15% 320 OVR T2 40-320 C U 2CTB802348R3700
1 – – – – – 347 ±15% 440 OVR T2 40-440 C U 2CTB802348R3900
1 – – – – – 480 ±15% 550 OVR T2 40-550 C U 2CTB802348R4100
1 – – – – – 600 ±15% 660 OVR T2 40-660 C U 2CTB802348R4300
Type 2 - Pluggable - Split Phase networks
2 – 15 5 – 0.6 120 ±15% 175 OVR T2 2L 15-150 P U 2CTB802343R0000
2 – 15 5 – 1 277 ±15% 320 OVR T2 2L 15-320 P U 2CTB802343R0400
3 – 15 5 – 0.7 120 ±15% 175 OVR T2 2N 15-150 P U 2CTB802344R0000
3 – 15 5 – 1.1 277 ±15% 320 OVR T2 2N 15-320 P U 2CTB802344R0400
2 – 40 20 – 0.6 120 ±15% 175 OVR T2 2L 40-150 P TS U 2CTB802343R2100
2 – 40 20 – 1 277 ±15% 320 OVR T2 2L 40-320 P TS U 2CTB802343R2500
3 – 40 20 – 0.7 120 ±15% 175 OVR T2 2N 40-150 P TS U 2CTB802344R2100
3 – 40 20 – 1.1 277 ±15% 320 OVR T2 2N 40-320 P TS U 2CTB802344R2500
3 – 40 10 – 1.4 347 ±15% 440 OVR T2 2N 40-440 P TS U 2CTB802344R2900
3 – 40 10 – 1.8 480 ±15% 550 OVR T2 2N 40-550 P TS U 2CTB802344R3300
3 – 40 10 – 2 600 ±15% 660 OVR T2 2N 40-660 P TS U 2CTB802344R3700
Cartridges
1 – – – – – 120 ±15% 175 OVR T2 15-150 C U 2CTB802348R2500
1 – – – – – 277 ±15% 320 OVR T2 15-320 C U 2CTB802348R2700
1 – – – – – 120 ±15% 175 OVR T2 40-150 C U 2CTB802348R3500
1 – – – – – 277 ±15% 320 OVR T2 40-320 C U 2CTB802348R3700
1 – – – – – 347 ±15% 440 OVR T2 40-440 C U 2CTB802348R3900
1 – – – – – 480 ±15% 550 OVR T2 40-550 C U 2CTB802348R4100
Type 2 - Pluggable - Grounded Wye networks
3 – 15 5 – 0.6 120 ±15% 175 OVR T2 3L 15-150 P U 2CTB802345R0000
4 – 15 5 – 0.6 120 ±15% 175 OVR T2 3N 15-150 P U 2CTB802346R0000
4 – 15 5 – 1.2 277 ±15% 320 OVR T2 3N 15-320 P U 2CTB802346R0400
3 – 40 20 – 0.6 120 ±15% 175 OVR T2 3L 40-150 P TS U 2CTB802345R2100
3 – 40 10 – 1.3 347 ±15% 440 OVR T2 3L 40-440 P TS U 2CTB802345R2900
4 – 40 20 – 1.2 120 ±15% 175 OVR T2 3N 40-150 P TS U 2CTB802346R2100
4 – 40 20 – 1.2 277 ±15% 320 OVR T2 3N 40-320 P TS U 2CTB802346R2500
4 – 40 10 – 1.2 347 ±15% 440 OVR T2 3N 40-440 P TS U 2CTB802346R2900
4 – 40 10 – 1.2 480 ±15% 550 OVR T2 3N 40-550 P TS U 2CTB802346R3300
4 – 40 10 – 1.2 600 ±15% 660 OVR T2 3N 40-660 P TS U 2CTB802346R3700
Cartridges
1 – – – – – 120 ±15% 175 OVR T2 15-150 C U 2CTB802348R2500
1 – – – – – 120 ±15% 175 OVR T2 40-150 C U 2CTB802348R3500
1 – – – – – 347 ±15% 440 OVR T2 40-440 C U 2CTB802348R3900
1 – – – – – 277 ±15% 320 OVR T2 15-320 C U 2CTB802348R2700
1 – – – – – 277 ±15% 320 OVR T2 40-320 C U 2CTB802348R3700
1 – – – – – 480 ±15% 550 OVR T2 40-550 C U 2CTB802348R4100
1 – – – – – 600 ±15% 660 OVR T2 40-660 C U 2CTB802348R4300
5/78 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 surge protective devices - Single pole
Descripiton
Single pole devices provide great flexibility for any kind of network configuration.
OVR T2 devices provide the best protection as they are designed to protect electric installations and
5
sensitive equipment against indirect surges with ensuring a low protection level (VPR). They are
characterized by their capacity to safely discharge current with 8/20 μs wave form.
OVR T2 70 N P U
5/79
—
Protection and safety
OVR Type 2 surge protective devices - Single phase networks
Description
Single phase devices are composed by a MOV pole plus a spark gap one. The spark gap pole guarantees
the lowest voltage protection rating and has to be connected to the Neutral.
5
OVR T2 devices provide the best protection as they are designed to protect electric installations and
sensitive equipment against indirect surges with ensuring a low protection level (VPR). They are char-
acterized by their capacity to safely discharge current with 8/20 μs wave form.
OVR T2 1N 40-150 P U
Ordering details
Pro- Max Nominal Voltage Nominal Max. Bbn Type Order code Weight
tected dis- dis- protec- voltage cont. 3660308
lines charge charge tion operat- Pkg
current current rating ing (1 pce)
Imax voltage
8/20 In VPR Un MCOV,
Uc
kA kA kV V V EAN kg
Pluggable
—
Protection and safety
OVR Type 2 surge protective devices - Single pole
5
—
Protection and safety
OVR Type 2 surge protective devices - Single pole
5
OVR T2 40-320 P U – – – OVR T2 70 N P U
OVR T2 40-320 P TS U OVR T2 40-440 P TS U OVR T2 40-550 P TS U OVR T2 40-660 P TS U –
Varistor Varistor Varistor Varistor Spark gap
2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm²
2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm²
12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm
2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm
1 NO – 1 NC 1 NO – 1 NC 1 NO – 1 NC 1 NO – 1 NC –
12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA –
250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A –
1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² –
V0 V0 V0 V0 V0
88 x 17.8 x 64.8 mm – – – 88 x 17.8 x 64.8 mm
3.46 x 0.7 x 2.55 in – – – 3.46 x 0.7 x 2.55 in
96 x 17.8 x 64.8 mm 96 x 17.8 x 64.8 mm 96 x 17.8 x 64.8 mm 96 x 17.8 x 64.8 mm –
3.78 x 0.7 x 2.55 in 3.78 x 0.7 x 2.55 in 3.78 x 0.7 x 2.55 in 3.78 x 0.7 x 2.55 in –
—
Protection and safety
OVR Type 2 surge protective devices - Single phase networks
5
—
Protection and safety
OVR Type 2 surge protective devices - Single phase networks
5
– – – –
OVR T2 1N 40-320 P TS U OVR T2 1N 40-440 P TS U OVR T2 1N 40-550 P TS U OVR T2 1N 40-660 P TS U
2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm²
2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm²
12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm
2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm
2 NO – 2 NC 2 NO – 2 NC 2 NO – 2 NC 2 NO – 2 NC
12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA
250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A
1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm²
—
Protection and safety
OVR Type 2 surge protective devices - Delta networks
Description
Delta devices provide the protection required by the three phases of a Delta network system.
OVR T2 devices provide the best protection as they are designed to protect electric installations and
5
sensitive equipment against indirect surges with ensuring a low protection level (VPR). They are char-
acterized by their capacity to safely discharge current with 8/20 μs wave form.
Ordering details
OVR T2 3L 15-320 P U
Pro- Max Nominal Voltage Nominal Max. Bbn Type Order code Weight
tected dis- dis- protec- voltage cont. 3660308
lines charge charge tion operat- Pkg
current current rating ing (1 pce)
Imax voltage
8/20 In VPR Un MCOV,
Uc
kA kA kV V V EAN kg
Pluggable
—
Protection and safety
OVR Type 2 surge protective devices - Delta networks
5
General technical data
Type OVR T2 3L 15-320 P U – –
with auxiliary contact (TS) – OVR T2 3L 40-320 P TS U OVR T2 3L 40-550 P TS U
Electrical features
Standards UL 1449 UL 1449 UL 1449
Type / test class (UL 1449) 1 1 1
Protected lines 3 3 3
Type of current / frequency AC 47-63 Hz AC 47-63 Hz AC 47-63 Hz
Voltage regulation of the system network ±15% ±15% ±15%
Nominal system voltage Un 277 V 277 V 480 V
Maximum continuous operating voltage MCOV 320 V 320 V 550 V
Maximal discharge current (8/20) Imax 15 kA 40 kA 40 kA
Nominal discharge current (8/20) In 5 kA 20 kA 10 kA
Voltage protection rating (L-N / N-G / L-G) VPR 1 kV 1 kV 1.7 kV
Response time < 25 ns < 25 ns < 25 ns
Short circuit SCCR 200 kA 200 kA 200 kA
withstand
Back up protection fuse (gG - gL) ≤ 100 A ≤ 100 A ≤ 100 A
maximum rating circuit breaker (B or C curve) ≤ 125 A ≤ 125 A ≤ 125 A
Pluggable Yes Yes Yes
cartridges
Integrated QuickSafe® technology Yes Yes Yes
State indicator Yes Yes Yes
Safety reserve – – –
Auxiliary contact No Yes Yes
(TS)
Installation
Wire range (L,N,PE) solid wire 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm²
stranded wire 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm²
Stripping length (L,N,PE) 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm
Tightening torque (L,N,PE) 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm
Auxiliary contact (TS)
Contact – 3 NO – 3 NC 3 NO – 3 NC
information
Min. load – 12 V DC – 10 mA 12 V DC – 10 mA
Max. load – 250 V AC – 1 A 250 V AC – 1 A
Connection cross section – 1.5 / 16 mm² 1.5 / 16 mm²
Miscellaneous characteristics
Stocking temperature -40...+80 °C -40...+80 °C -40...+80 °C
Maximal Altitude 5 000 m 5 000 m 5 000 m
Operating temperature -40...+176 °C -40...+176 °C -40...+176 °C
Degree of NEMA 1 NEMA 1 NEMA 1
protection
Fire resistance according to UL 94 V0 V0 V0
Dimensions mm hxwxd 90.5 x 53.4 x 64.8 mm – –
inches hxwxd 3.56 x 2.1 x 2.55 in – –
Dimensions with mm hxwxd – 98.5 x 53.4 x 64.8 mm 98.5 x 53.4 x 64.8 mm
auxiliary contact inches hxwxd – 3.88 x 2.1 x 2.55 in 3.88 x 2.1 x 2.55 in
(TS)
Replacement cartridges
Phase product ID Type OVR T2 15-320 C U OVR T2 40-320 C U OVR T2 40-550 C U
Order code 2CTB802348R2700 2CTB802348R3700 2CTB802348R4100
Neutral product ID Type – – –
Order code – – –
5/86 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 surge protective devices - Split phase networks
Description
Split phase devices are composed by two MOV poles or two MOV poles plus a spark gap one, depend-
ing on the number of lines the customer wants to pretect.The spark gap pole guarantees the lowest
5
Ordering details
Pro- Max Nominal Voltage Nominal Max. Bbn Type Order code Weight
tected dis- dis- protec- voltage cont. 3660308
lines charge charge tion operat- Pkg
current current rating ing (1 pce)
Imax voltage
8/20 In VPR Un MCOV,
Uc
kA kA kV V V EAN kg
Pluggable
OVR T2 2N 40-440
P TS U
5/87
—
Protection and safety
OVR Type 2 surge protective devices - Grounded Wye networks
Description
Wye devices are composed by three MOV poles or three MOV poles plus a spark gap one, depending on
the number of lines the customer wants to protect. The spark gap pole guarantees the lowest voltage
5
protection rating and has to be connected to the Neutral.
OVR T2 devices provide the best protection as they are designed to protect electric installations and
sensitive equipment against indirect surges with ensuring a low protection level (VPR). They are char-
acterized by their capacity to safely discharge current with 8/20 μs wave form.
OVR T2 3L 40-440
P TS U
Ordering details
Pro- Max Nominal Voltage Nominal Max. Bbn Type Order code Weight
tected dis- dis- protec- voltage cont. 3660308
lines charge charge tion operat- Pkg
current current rating ing (1 pce)
Imax voltage
8/20 In VPR Un MCOV,
Uc
kA kA kV V V EAN kg
Pluggable
—
Protection and safety
OVR Type 2 surge protective devices - Split phase networks
5
—
Protection and safety
OVR Type 2 surge protective devices - Split phase networks
5
OVR T2 2N – – – – –
15-320 P U
– OVR T2 2N OVR T2 2N OVR T2 2N OVR T2 2N OVR T2 2N
40-150 P TS U 40-320 P TS U 40-440 P TS U 40-550 P TS U 40-660 P TS U
2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm²
2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm²
12.5 / 0.5 12.5 / 0.5 12.5 / 0.5 12.5 / 0.5 12.5 / 0.5 12.5 / 0.5
2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm
– 3 NO – 3 NC 3 NO – 3 NC 3 NO – 3 NC 3 NO – 3 NC 3 NO – 3 NC
– 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA
– 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A
– 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm²
– 3.88 x 2.1 x 2.55 in 3.88 x 2.1 x 2.55 in 3.88 x 2.1 x 2.55 in 3.88 x 2.1 x 2.55 in 3.88 x 2.1 x 2.55 in
– 1 NO – 1 NC 1 NO – 1 NC 1 NO – 1 NC 1 NO – 1 NC 1 NO – 1 NC
OVR T2 15-320 C U OVR T2 40-150 C U OVR T2 40-320 C U OVR T2 40-440 C U OVR T2 40-550 C U OVR T2 40-660 C U
2CTB802348R2700 2CTB802348R3500 2CTB802348R3700 2CTB802348R3900 2CTB802348R4100 2CTB802348R4300
OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U
2CTB802348R6500 2CTB802348R6500 2CTB802348R6500 2CTB802348R6500 2CTB802348R6500 2CTB802348R6500
5/90 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVR Type 2 surge protective devices - Grounded Wye networks
5
—
Protection and safety
OVR Type 2 surge protective devices - Grounded Wye networks
5
OVR T2 3N – – – – –
15-320 P U
– OVR T2 3N OVR T2 3N OVR T2 3N OVR T2 3N OVR T2 3N
40-150 P TS U 40-320 P TS U 40-440 P TS U 40-550 P TS U 40-660 P TS U
2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm² 2.5…25 / 4…14 mm²
2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm² 2.5…16 / 6…14 mm²
12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm 12.5 / 0.5 mm
2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm 2.8 / 24.5 Nm
– 4 NO – 4 NC 4 NO – 4 NC 4 NO – 4 NC 4 NO – 4 NC 4 NO – 4 NC
– 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA 12 V DC – 10 mA
– 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A 250 V AC – 1 A
– 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm² 1.5 / 16 mm²
OVR T2 15-320 C U OVR T2 40-150 C U OVR T2 40-320 C U OVR T2 40-440 C U OVR T2 40-550 C U OVR T2 40-660 C U
2CTB802348R2700 2CTB802348R3500 2CTB802348R3700 2CTB802348R3900 2CTB802348R4100 2CTB802348R4300
OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U OVR T2 70 N C U
2CTB802348R6500 2CTB802348R6500 2CTB802348R6500 2CTB802348R6500 2CTB802348R6500 2CTB802348R6500
5/92 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVRH series product range
5
Name OVRHSP OVRHSP (120, 160) OVRHSP (60, 80, 100) OVRHSR (120, 160)
(200, 240, 300, 400)
Connection Ampacity 1,000A 1,000A 400A 1,000A
and higher and below and below and below
SPD Type Type 1 Type 1 Type 1 Type 1
Certifications UL 1449 UL 1449 UL 1449 UL 1449
Surge Ratings 200, 240, 300, 400kA per 120, 160kA per phase 60, 80, 100kA per phase 120, 160kA per phase
phase
LEDs Yes Yes Yes Yes
Dry Relay Contacts Standard Standard Optional Standard
EMI Filter Optional Optional Optional Optional
Surge Counter Optional Optional Not available Not available
Warranty 10 years 10 years 10 years 10 years
5/93
—
Protection and safety
OVRH series product range
5
OVRHT3B OVRHT3C OVRHS3U OVRHLD
—
Protection and safety
OVRHSP/OVRHSR Facility Wide Protection – 4,000A and below
• Listed to UL 1449 4th Edition for Type 1 and Type 2 SPD applications.
• Fail-safe design with individually fused Metal Oxide Varistors (MOVs) eliminating single
point failure, protecting against both overcurrent and overvoltage events.
5
• 200kAIC short circuit rating permits direct bus connection to most electrical services.
• Low let through voltage ensured by the lowest possible impedance path to ground and
equal current sharing during surge events.
• All weather sealed, powder-coated NEMA 4/IP65 housing is designed for any orientation
and indoor/outdoor applications.
• 10 years standard warranty.
Technical features
Electrical
Nominal discharge current 10kA (60–100) 20kA (120–400)
rating (I-n)
Operating frequency 47–63Hz
Connection method Parallel to electrical distribution system
Modes of protection All modes (L-N, L-G, N-G, L-L)
Fault rating (SCCR) 200kAIC–no upstream over-current protection device (breaker or fuse) required
Standard monitoring tatus indicator lights (one per phase), Standard dry (Form “C”) relay contacts,
S
(120–400 kA) Audible alarm with silence button
Mechanical
Weight 0, 80, 100 kA: 4.5 kg (10 lbs.)
6
120, 160 kA: 9 kg (20 lbs.)
200, 240, 300, 400 kA: 18 kg (40 lbs.)
Enclosure type Powder coated, impact-resistance steel, weather-proof NEMA 4
Installation location Indoor/outdoor
Mounting method Dual mounting flanges
Operating environment - 40° to +70°C (-40° to +185°F)
Altitude Up to 4000 m (13,000 ft.)
Product design Parallel design with individually fused MOVs
Regulatory
UL 1449 4th Edition Type Type 1
UL 1283 Yes
IEEE C62.41.1, .2, C62.45 Yes
Listed by TL: 60–100kA models
E
UL: 120–400kA models
5/95
—
Protection and safety
OVRHSP/OVRHSR Facility Wide Protection – 4,000A and below
5
Order piece
EAN Type code code kg pc.
1-phase, 2-wire + ground 120V OVRHSP(SR)xxx1201P
1-phase, 2-wire + ground 240V OVRHSP(SR)xxx2401P
2-phase, 3-wire + ground 240/120 V OVRHSP(SR)xxx1202S
3-phase Wye, 4-wire + 208Y/120 V OVRHSP(SR)xxx1203Y
ground
3-phase Wye, 4-wire + 380Y/220 V OVRHSP(SR)xxx2203Y
ground
3-phase Wye, 4-wire + 415Y/240 V OVRHSP(SR)xxx2403Y
ground
3-phase Wye, 4-wire + 480Y/277 V OVRHSP(SR)xxx2773Y
ground
3-phase Wye, 4-wire + 600Y/347 V OVRHSP(SR)xxx3473Y*
ground
3-phase High-Leg, 4-wire 240Δ/120 V OVRHSP(SR)xxx2403H
+ ground
3-phase Delta, 3-wire + 240V OVRHSP(SR)xxx2403D
ground
3-phase Delta, 3-wire + 380V OVRHSP(SR)xxx3803D*
ground
3-phase Delta, 3-wire + 480V OVRHSP(SR)xxx4803D*
ground
3-phase Delta, 3-wire + 600V OVRHSP(SR)xxx6003D*
ground
OVRHSP: Where “xxx” can be 60, 80, 100, 120, 160, 200, 240, 300 or 400
OVRHSR: Where “xxx” can be 120 or 160
*Voltages not available with 60, 80 or 100kA units
—
Protection and safety
OVRHT3B Sub Distribution and Panelboard – 400A and below
Technical features
Electrical
Nominal discharge current rating (I-n) 20 kA (Earthling systems 10 kA)
Operating frequency 47–63 Hz
Connection methods arallel to load (shunt)
P
914.4 mm (36") of 3.31 mm2 (#12 AWG) wires
Modes of protection Model dependent
Fault rating (SCCR) 100 kA IC
Standard monitoring LED status indicator lights
Mechanical
Weight 23 kg (5 lbs)
Enclosure type NEMA 4X, non metallic
Installation location Indoor/Outdoor
Mounting method 12.7 mm (1/2")–14 NPT thread
Operating environment -35 to +80 °C (-31 to +176 °F)
Altitude Up to 5000 m (16,400 ft.)
Product design Individual thermally fused and protected MOVs
Regulatory
UL 1449 4th edition type Type 1
UL 96A Yes
IEEE C62.41.1, .2, C62.45 Yes
Listed by UL
5/97
—
Protection and safety
OVRHT3B Sub Distribution and Panelboard – 400A and below
5
1-phase, 2-wire 50kA 120 V OVRHT3B501201P 2CJC405120P0000 0.23 1
+ ground
1-phase, 2-wire 50kA 240 V OVRHT3B502401P 2CJC405240P0000 0.23 1
+ ground
1-phase, 2-wire 50kA 277 V OVRHT3B502771P 2CJC405277P0000 0.23 1
+ ground
1-phase, 2-wire 50kA 480 V OVRHT3B504801P 2CJC405480P0000 0.23 1
+ ground
2-phase, 3-wire 50kA 240/120 V OVRHT3B501202S 2CJC405120S0000 0.23 1
+ ground
2-phase, 3-wire 50kA 480/240 V OVRHT3B502402S 2CJC405240S0000 0.23 1
+ ground
3-phase High-Leg, 50kA 240Δ/120 V OVRHT3B502403H 2CJC405240H0000 0.23 1
4-wire + ground
3-phase Wye, 4-wire 50kA 208Y/120 V OVRHT3B501203Y 2CJC405120Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 380Y/220 V OVRHT3B502203Y 2CJC405220Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 400Y/230 V OVRHT3B502303Y 2CJC405230Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 415Y/240 V OVRHT3B502403Y 2CJC405240Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 480Y/277 V OVRHT3B502773Y 2CJC405277Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 600Y/347 V OVRHT3B503473Y 2CJC405347Y0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 240 V OVRHT3B502403D 2CJC405240D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 380 V OVRHT3B503803D 2CJC405380D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 400 V OVRHT3B504003D 2CJC405400D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 480 V OVRHT3B504803D 2CJC405480D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 600 V OVRHT3B506003D 2CJC405600D0000 0.23 1
+ ground
Earthing Systems
1-phase, 2-wire + 50kA 230V OVRHT3B502301PI 2CJC405230I0000 0.23 1
ground (for TNC
earthing systems)
1-phase, 2-wire + 50kA 230V OVRHT3B502301PJ 2CJC405230J0000 0.23 1
ground (for TNS
earthing systems)
1-phase, 2-wire + 50kA 230V OVRHT3B502301PK 2CJC405230K0000 0.23 1
ground (for IT
earthing systems)
1-phase, 2-wire + 50kA 230V OVRHT3B502301PL 2CJC405230L0000 0.23 1
ground (for TT
earthing systems)
Warranty
3-year
5/98 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVRHS3U Sub Distribution and Panelboard – 400A and below
• Listed to UL 1449 4th Edition for Type 1 and Type 2 SPD applications.
• Individual fusing for each Metal Oxide Varistors (MOVs).
• LED indicates proper functioning of L-N and N-G MOVs.
5
Technical features
Electrical
Nominal discharge current rating (I-n) 20kA
Operating frequency 47–63Hz
Connection methods arallel to load (shunt)
P
2 mm2 (#14 AWG) wires
Modes of protection Model dependent
Fault rating (SCCR) 100kAIC
Standard monitoring LED status indicator lights
Mechanical
Weight 0.9 kg (2 lbs.)
Enclosure type NEMA 1, non-metallic
Installation location Indoor
Mounting method 2.7 mm (1/2”)–14 NPT thread
1
(Aluminum bracket optional)
Operating environment -40 to +80 °C (-40 to +176 °F)
Altitude Up to 5000 m (16,400 ft.)
Product design Individually fused MOVs
Regulatory
UL 1449 4th edition type Type 1 and Type 2
UL 1283 nly for model number
O
OVRHS3U802402SR
IEEE C62.41.1, .2, C62.45 Yes
Listed by UL
5/99
—
Protection and safety
OVRHS3U Sub Distribution and Panelboard – 400A and below
Type 1
Configuration kA Voltage Bbn Order details Price Weight Pack
per 8012542 1 1 piece unit
5
phase piece
EAN Type code Order code kg pc.
1-phase, 2-wire + 40kA 120 V OVRHS3U401201P
ground
2-phase, 3-wire + 40kA 120/240 V OVRHS3U401202S
ground
3-phase Delta, 4-wire 40kA 240 V OVRHS3U402403D
+ ground
3-phase, 4-wire + 40kA 120/208 V OVRHS3U402083Y
ground
120 V OVRHS3U401201P 2CJB504120P0000 0.9 1
240/120 V OVRHS3U401202S 2CJB504120S0000 0.9 1
240 V OVRHS3U402403D 2CJB504240D0000 0.9 1
208Y/120 V OVRHS3U401203Y 2CJB504120Y0000 0.9 1
240 V OVRHS3U402401P 2CJB504240P0000 0.9 1
480 V OVRHS3U404803D 2CJB504480D0000 0.9 1
240Δ/120 V OVRHS3U401203H 2CJB504120H0000 0.9 1
480Y/277 V OVRHS3U402773Y 2CJB504277Y0000 0.9 1
400Y/230 V OVRHS3U402303Y 2CJB504230Y0000 0.9 1
Type 2
Configuration kA per Voltage Bbn Order details Price Weight Pack
phase 8012542 1 1 piece unit
piece
EAN Type code Order code kg pc.
1-phase, 2-wire + ground 40kA 240V OVRHS3U402401P
3-phase Delta, 3-wire + 40kA 480V OVRHS3U404803D
ground
3-phase High-Leg, 4-wire 40kA 120/240V OVRHS3U401202H
+ ground
3-phase, 4-wire + ground 40kA 277/480V OVRHS3U402773Y
3-phase, 4-wire + ground 40kA 230/400V OVRHS3U402303Y
—
Protection and safety
OVRHT3C Sub Distribution and Panelboard – 400A and below
Technical features
Electrical
Nominal discharge current rating (I-n) 10kA
Operating Frequency 47–63Hz
Connection Methods Parallel to load
914.4mm (36“) of 3.31mm2 (#12 AWG)
wires
Modes of protection Model dependent
Fault rating (SCCR) 100kAIC
Standard monitoring LED status indicator lights
Mechanical
Weight .23 kg (.5 lbs)
Enclosure type NEMA 4X, non metallic
Installation location Indoor/Outdoor
Mounting method 12.7mm (1/2”)–14 NPT thread
Operating environment -35° to +80°C (-31° to +176°F)
Altitude Up to 5000 m (16,400 ft.)
Product design Individual thermally fused and protected MOVs
Regulatory
UL 1449 4th edition type Type 1
UL 96A Yes
IEEE C62.41.1, .2, C62.45 Yes
Listed by UL
5/101
—
Protection and safety
OVRHT3C Sub Distribution and Panelboard – 400A and below
5
1-phase, 2-wire 50kA 120V OVRHT3C501201P 2CJC605120P0000 0.23 1
+ ground
1-phase, 2-wire 50kA 240V OVRHT3C502401P 2CJC605240P0000 0.23 1
+ ground
1-phase, 2-wire 50kA 277V OVRHT3C502771P 2CJC605277P0000 0.23 1
+ ground
1-phase, 2-wire 50kA 480V OVRHT3C504801P 2CJC605480P0000 0.23 1
+ ground
2-phase, 3-wire 50kA 240 V/120 V OVRHT3C501202S 2CJC605120S0000 0.23 1
+ ground
2-phase, 3-wire 50kA 480 V/240 V OVRHT3C502402S 2CJC605240S0000 0.23 1
+ ground
3-phase High-Leg, 50kA 240Δ/120 V OVRHT3C502403H 2CJC605240H0000 0.23 1
4-wire + ground
3-phase Wye, 4-wire 50kA 208Y/120 V OVRHT3C501203Y 2CJC605120Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 380Y/220 V OVRHT3C502203Y 2CJC605220Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 400Y/230 V OVRHT3C502303Y 2CJC605230Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 415Y/240 V OVRHT3C502403Y 2CJC605240Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 480Y/277 V OVRHT3C502773Y 2CJC605277Y0000 0.23 1
+ ground
3-phase Wye, 4-wire 50kA 600Y/347 V OVRHT3C503473Y 2CJC605347Y0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 240 V OVRHT3C502403D 2CJC605240D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 380 V OVRHT3C503803D 2CJC605380D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 400 V OVRHT3C504003D 2CJC605400D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 480 V OVRHT3C504803D 2CJC605480D0000 0.23 1
+ ground
3-phase Delta, 3-wire 50kA 600 V OVRHT3C506003D 2CJC605600D0000 0.23 1
+ ground
Earthing Systems
1-phase, 2-wire + 50kA 230 V OVRHT3C502301PI 2CJC605230I0000 0.23 1
ground (for TNC
earthing systems)
1-phase, 2-wire + 50kA 230 V OVRHT3C502301PJ 2CJC605230J0000 0.23 1
ground (for TNS
earthing systems)
1-phase, 2-wire + 50kA 230 V OVRHT3C502301PK 2CJC605230K0000 0.23 1
ground (for IT
earthing systems)
1-phase, 2-wire + 50kA 230 V OVRHT3C502301PL 2CJC605230L0000 0.23 1
ground (for TT
earthing systems)
Warranty
3-year
5/102 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
OVRHLD Equipment Level Protection – 100A and below
Technical features
Electrical
Nominal discharge current rating (I-n) 10kA
Operating frequency 47–63Hz
Connection methods arallel to load (shunt)
P
457.2 mm (18”) 2mm2 (#14 AWG) wires
Direct connect or breaker
Modes of protection L-N, L-G, N-G
Fault rating (SCCR) 65kAIC
Standard monitoring ED status indicator lights
L
(one per phase)
Mechanical
Weight .5 kg (1 lb.)
Enclosure type NEMA 1, non-metallic
Installation location Indoor
Mounting method NPS thread and aluminum bracket
Operating environment -40° to +80°C (-40° to +176°F)
Altitude Up to 5000 m (16,400 ft.)
Product design I ndividually fused MOVs
Overcurrent fusing
Thermal fusing
Regulatory
UL 1449 4th edition type Type 1
UL 1283 No
IEEE C62.41.1, .2, C62.45 Yes
Listed by ETL
Model number: Where “xx” can be 20, 25 or 30 and “yyy” can be 120, 127, 230, or 277
Description: Where “xx” can be 20, 25 or 30 and “yyy” can be 120, 127, 230, or 277
—
Notes
5
5/104 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
The new ABB OVR data and telecom
SPD range overview
Protecting critical electronic systems
5
The new ABB OVR data/telecom range of SPDs are designed to protect equip-
ment connected to data and telephone lines to complement the OVR power Data/
Telecom
SPD products and offer a complete system protection solution (power & data)
against surges. The comprehensive range includes protection for twisted pair
data lines (including hazardous environments), computer networks, telecom
Power
systems including PBX and ISDN, CCTV, TV and RF systems.
Cables leaving the building can also provide a route back into the building
for transients.
—
Protection and safety
Short Selection Guide – Surge Protection Devices OVR
PROFIBUS
Systems
5
OVR RS485 OVR SL RS485 OVR RS485Q
HART Systems Flat/DIN Mount Slim DIN Mount Multiple Lines (DIN Mount)
7TCA085400R0310 7TCA085400R0310 7TCA085400R0312
Video
CCTV Protection
Surveillance
is also available for
CCTV 5V CCTV with BNC OVR CCTV/B OVR RS485 OVR 240-16A OVR CME4 OVR WBX4/GS different voltages
connector, power, Video signal Telemetry signal Power line Earth Bar Enclosure and twisted pair
and telemetry line 7TCA085400R0296 7TCA085400R0310 7TCA085460R0361 7TCA085400R0414 7TCA085410R0049 connections.
4 - 20 mA
current loops
Screw terminals OVR SL30L/4-20
30 V 7TCA085400R0371
Coaxial antennas:
GSM, UMTS, Female OVR RF 441421 OVR RF AA1421 OVR RF 111421
Radar, Radio, TV, coaxial BNC 7/16 DIN N
GPS connector: 7TCA085450R0066 7TCA085450R0063 7TCA085450R0065
2 wire systems
(30V) OVR 30E OVR SL30 OVR 30Q Protection for
Flat Mount Slim Mount Multiple Lines different voltages
7TCA085400R0353 7TCA085400R0363 7TCA085400R0341 are available
3 wire systems
(30V) OVR SL30/3W Protection for
Slim Mount different voltages
7TCA085400R0331 are available
Hazardous Areas
Data/
ATEX/IEC Telecom
OVR SL15X OVR SL30X
approved 15 Volt 30 Volt
7TCA085400R0386 7TCA085400R0387
Power
Resistance
Temperature WARNING Equipment is ONLY
Detectors (RTD) OVR RTD OVR SL RTD OVR RTDQ protected if all incoming lines
Flat/DIN Mount Slim (DIN Mount) Multiple Lines (DIN Mount) have protection fitted
7TCA085400R0313 7TCA085400R0315 7TCA085400R0314
5/106 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR SL Series
5
Application Installation
Use these protectors where installation space is at Connect in series with the data communication or signal
a premium and large numbers of lines require protection line either near where it enters or leaves the building or
(e.g. process control, high speed digital communication close to the equipment being protected (e.g. within its
equipment or systems with long signal lines). control panel).
Either way, it must be very close to the system’s earth
star point. Install protectors either within an existing
cabinet/cubicle or in a separate enclosure.
7TCA085400R0366
CLEAN
Replacement modules: OVR SL/I/B Nominal voltage
Current rating
In-line resistance
30V
Max working voltage, Uc 36.7V
750mA
Ω
1.0Ω
1.0
S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
NOTE: The OVR SL ‘Slim Line’ Series is also available for protection of 3-wire, RS 485 and RTD applications (OVR SL/3W, OVR SL RS485 & OVR SL RTD).
The OVR SL X Series has approvals for use in hazardous areas. For telecommunication applications use OVR SLTN Series.
5/107
—
Protection and safety
Data & signal protection
OVR SL Series
OVR SL Series - Technical specification
Electrical specification OVR SL06 OVR SL15 OVR SL30 OVR SL50 OVR SL110
ABB order code 7TCA085400R0360 7TCA085400R0361 7TCA085400R0363 7TCA085400R0364 7TCA085400R0362
5
Nominal voltage (1) 6V 15 V 30 V 50 V 110 V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V 11 V/16.7 V 25 V/36.7 V 40 V/56.7 V 93 V/132 V
Current rating (signal) 750 mA
In-line resistance (per line ±10%) 1.0 Ω
Bandwidth (-3 dB 50 Ω system) 45 MHz 45 MHz 45 MHz 45 MHz 45 MHz
Transient specification OVR SL06 OVR SL15 OVR SL30 OVR SL50 OVR SL110
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs 36.0 V 38.4 V 63.0 V 90.3 V 185 V
to BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs 26.2 V 29.4 V 51.3 V 77.2 V 175 V
to BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs 16.0 V 26.8 V 45.4 V 68.3 V 165 V
to BS EN/EN/IEC 61643-21
5 kV, 10/700 μs (4) 17.0 V 27.5 V 46.3 V 69.1 V 170 V
Maximum surge current
D1 test 10/350 μs to – Per signal wire 1.25 kA
BS EN/EN/IEC 61643-21 – Per pair 2.5 kA
8/20 μs to ITU-T – Per signal wire 10 kA
K.45:2003, – Per pair 20 kA
IEEE C62.41.2:2002
Mechanical specification OVR SL06 OVR SL15 OVR SL30 OVR SL50 OVR SL110
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.8 Nm
Conductor size (stranded) 4 mm2
Earth connection Via DIN rail or 4 mm2 earth terminal - maximum torque 0.8 Nm
Case material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg
– Packaged (per 10) 0.85 kg
Dimensions See diagram below
104.6 mm
106.5 mm
7 mm 2 S 1 1 S 2 E
(1)
ominal voltage (RMS/DC or AC peak)
N
measured at < 10 μA (OVR SL15, OVR SL30,
OVR SL50, OVR SL110 and LED variants)
and < 200 μA (OVR SL06 and OVR SL06L)
(2)
Maximum working voltage (RMS/DC or AC peak)
measured at < 1 mA leakage
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45, Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/108 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR SL X Series
5
Application Installation
Use these protectors in hazardous environments where in- Connect in series with the data communication or signal
stallation space is at a premium and large numbers of lines line either near where it enters or leaves the building or close
require protection (e.g. process control, 4-20 mA loops, to the equipment being protected (e.g. within its control
fire and gas detectors and shut-down systems). Suitable panel). Either way, it must be very close to the system’s
for high speed digital communication equipment or systems earth star point. Install protectors either within an existing
with long signal lines. See Application Note OVR AN013. cabinet/cubicle or in a separate enclosure.
CLEAN
7TCA085400R0397
Current rating
30V
Max working voltage, Uc 36.7V
750mA
1 3
Max surge current 20kA
Let-through voltage, Up 63V
S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
NOTE: Use the standard OVR SL ‘Slim Line’ Series for non-hazardous areas. The OVR SL Series is also available for protection
of 3-wire, RS 485, RTD & telecommunication applications (OVR SL/3W, OVR SL RS485, OVR SL RTD & OVR SL TN).
5/109
—
Protection and safety
Data & signal protection
OVR SL X Series
OVR SL X Series - Technical specification
Electrical specification OVR SL15X OVR SL30X
ABB order code 7TCA085400R0386 7TCA085400R0387
5
Nominal voltage (1) 15 V 30 V
Maximum working voltage Uc (RMS/DC) (2) 11 V/16.7 V 25 V/36.7 V
Current rating (signal) 750 mA
In-line resistance (per line ±10%) 1.0 Ω
Bandwidth (-3 dB 50 Ω system) 45 MHz
Intrinsically safe specification OVR SL15X OVR SL30X
Maximum voltage Ui 30 V
Maximum power Pi – Per -40 °C < Ta < 40 °C 1.3 W
– Per -40 °C < Ta < 60 °C 1.2 W
– Per -40 °C < Ta < 80 °C 1.0 W
Capacitance Ci 0 μF
Inductance Li 0 μH
Certificate number IECEx SIR 10.0030X, Sira 10ATEX2063X
Classification Ex II 2 (1) G, Ex ia (ia Ga) IIC T4 Gb
Transient specification OVR SL15X OVR SL30X
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to BS EN/EN/IEC 61643-21 38.4 V 63.0 V
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to BS EN/EN/IEC 61643-21 29.4 V 51.3 V
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21 26.8 V 45.4 V
5 kV, 10/700 μs (4) 27.5 V 46.3 V
Maximum surge current
D1 test 10/350 μs to BS EN/EN/ – Per signal wire 1.25 kA
IEC 61643-21 – Per pair 2.5 kA
8/20 μs to ITU-T K.45:2003, – Per signal wire 10 kA
IEEE C62.41.2:2002 – Per pair 20 kA
Mechanical specification OVR SL15X OVR SL30X
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.8 Nm
Conductor size (stranded) 4 mm2
Earth connection Via DIN rail or 4 mm2 earth terminal - maximum torque 0.8 Nm
Case material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg
– Packaged (per 10) 0.85 kg
Dimensions See diagram below
104.6 mm
(1)
ominal voltage (RMS/DC or AC peak)
N
106.5 mm
measured at < 10 μA
(2)
Maximum working voltage (RMS/DC or AC peak)
measured at < 1 mA leakage 7 mm 2 S 1 1 S 2 E
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45, Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/110 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR D Series
5
Application Installation
Use on twisted pair lines, e.g. those found in process Connect in series with the data communication or signal line
control equipment, modems and computer either near where it enters or leaves the building or close to
communications interfaces. the equipment being protected (e.g. within its control
panel). Either way, it must be very close to the system’s
earth star point. Install protectors either within an existing
cabinet/cubicle or in a separate enclosure.
Accessories
Combined Mounting/Earthing kits: Weatherproof enclosures:
OVR CME 4 Mount & earth OVR WBX 4, OVR WBX 4/GS Install in series (in-line)
up to 4 protectors For use with a OVR CME 4
OVR CME 8 Mount & earth and up to 4 protectors DIRTY CLEAN
up to 8 protectors OVR WBX 8, OVR WBX 8/GS
OVR CME 16 Mount & earth For use with a OVR CME 8
up to 16 protectors and up to 8 protectors
OVR CME 32 Mount & earth OVR WBX 16/2/G
From line To
up to 32 protectors For use with one or two OVR CME
16 and up to 32 protectors equipment
Earth
Slim Line (OVR SL) and ATEX (OVR SLX) versions are also available. If your system requires a protector with a very low resistance or higher current, see the
OVR E & H Series. Also use the OVR E Series for systems needing a higher bandwidth. Protectors for 3-wire (OVR SL/3W) and RTD (OVR RTD, OVR SL RTD) are
available, as are the space saving protectors (OVR Q, OVR SL Series). The OVR KT and TN Series are additional protectors specifically for telephone lines.
5/111
—
Protection and safety
Data & signal protection
OVR D Series
OVR D Series - Technical specification
Electrical specification OVR 06D OVR 15D OVR 30D OVR 50D OVR 110D
ABB order code 7TCA085400R0288 7TCA085400R0349 7TCA085400R0351 7TCA085400R0352 7TCA085400R0347
5
Nominal voltage (1) 6V 15 V 30 V 50 V 110 V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V 13 V/19 V 26 V/37.1 V 41 V/58 V 93 V/132 V
Current rating (signal) 300 mA
In-line resistance (per line ±10%) 9.4 Ω 9.4 Ω 9.4 Ω 9.4 Ω 9.4 Ω
Bandwidth (-3 dB 50 Ω system) 800 kHz 2.5 MHz 4 MHz 6 MHz 9 MHz
Transient specification OVR 06D OVR 15D OVR 30D OVR 50D OVR 110D
Let-through voltage (all conductors)(3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 12.0 V 25.0 V 44.0 V 78.0 V 155 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 11.5 V 24.5 V 43.5 V 76.0 V 150 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/ 10.0 V 23.0 V 42.5 V 73.0 V 145 V
IEC 61643-21
5 kV, 10/700 μs (4) 10.5 V 23.8 V 43.4 V 74.9 V 150 V
Maximum surge current
D1 test 10/350 μs – Per signal wire 2.5 kA
to BS EN/EN/IEC – Per pair 5 kA
61643-21
8/20 μs to ITU-T – Per signal wire 10 kA
K.45:2003, IEEE – Per pair 20 kA
C62.41.2:2002
Mechanical specification OVR 06D OVR 15D OVR 30D OVR 50D OVR 110D
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.5 Nm
Conductor size (stranded) 2.5 mm2
Earth connection M6 stud
Case material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg
– Packaged (per 10) 0.85 kg
Dimensions See diagram below
54 mm
38 mm
105 mm
M4 clearance
120 mm
19 mm
109 mm
M4 clearance
(1)
ominal voltage (RMS/DC or AC peak)
N
measured at < 5 μA (OVR 15D, OVR 30D,
OVR 50D, OVR 110D) and < 200 μA (OVR 06D)
(2)
Maximum working voltage (RMS/DC or AC peak)
measured at < 1 mA leakage (OVR 15D, OVR 30D,
OVR 50D, OVR 110D), < 10 mA (OVR 06D)
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45, Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/112 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR E Series
5
Application Installation
Use these units to protect resistance sensitive, higher Connect in series with the data communication or signal line
frequency or running current systems, e.g. high speed either near where it enters or leaves the building or close to
digital communications equipment or systems with long the equipment being protected (e.g. within its control
signal lines. panel). Either way, it must be very close to the system’s
earth star point. Install protectors either within an existing
cabinet/cubicle or in a separate enclosure.
Accessories
Combined Mounting/Earthing kits: Weatherproof enclosures:
Install in series (in-line)
OVR CME 4 Mount & earth OVR WBX 4, OVR WBX 4/GS
up to 4 protectors For use with a OVR CME 4
OVR CME 8 Mount & earth and up to 4 protectors DIRTY CLEAN
up to 8 protectors OVR WBX 8, OVR WBX 8/GS
OVR CME 16 Mount & earth For use with a OVR CME 8
up to 16 protectors and up to 8 protectors
OVR CME 32 Mount & earth OVR WBX 16/2/G From line To
up to 32 protectors For use with one or two OVR CME
equipment
16 and up to 32 protectors
Earth
NOTE: Slim Line (OVR SL) and ATEX (OVR SLX) are available. For many twisted pair data and signal applications, the lower cost OVR D Series may be suitable.
For applications requiring higher current (1.25 A to 4 A) or ultra-low in-line resistance, the OVR H Series protectors may be more suitable.
5/113
—
Protection and safety
Data & signal protection
OVR E Series
OVR E Series - Technical specification
Electrical specification OVR 06E OVR 15E OVR 30E OVR 50E OVR 110E
ABB order code 7TCA085400R0346 7TCA085400R0350 7TCA085400R0353 7TCA085400R0354 7TCA085400R0348
5
Nominal voltage (1) 6V 15 V 30 V 50 V 110 V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V 11 V/16.7 V 25 V/36.7 V 40 V/56.7 V 93 V/132 V
Current rating (signal) 1.25 A
In-line resistance (per line ±10%) 1.0 Ω
Bandwidth (-3 dB 50 Ω system) 45 MHz
Transient specification OVR 06E OVR 15E OVR 30E OVR 50E OVR 110E
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 36.0 V 39.0 V 60.0 V 86.0 V 180 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 26.2 V 28.0 V 49.0 V 73.5 V 170 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 16.0 V 25.5 V 43.5 V 65.0 V 160 V
61643-21
5 kV, 10/700 μs (4) 17.0 V 26.2 V 44.3 V 65.8 V 165 V
Maximum surge current
D1 test 10/350 μs – Per signal wire 2.5 kA
to BS EN/EN/IEC
61643-21 – Per pair 5 kA
54 mm
38 mm
105 mm
M4 clearance
120 mm
19 mm
109 mm
M4 clearance
(1)
ominal voltage (RMS/DC or AC peak)
N
measured at < 10 μA (OVR 15E, OVR 30E,
OVR 50E, OVR 110E) and < 200 μA (OVR 06E)
(2)
Maximum working voltage (RMS/DC or AC peak)
measured at < 5 mA leakage (OVR 15E, OVR 30E,
OVR 50E, OVR 110E) and < 10 mA (OVR 06E)
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/114 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR H Series
5
Application Installation
Use these applications to protect resistance sensitive or Connect in series with the data communication or signal line
higher running current systems, e.g. systems with long either near where it enters or leaves the building or close to
signal lines, or DC power applications. the equipment being protected (e.g. within its control
panel). Either way, it must be very close to the system’s
earth star point. Install protectors either within an existing
cabinet/cubicle or in a separate enclosure.
Accessories
Combined Mounting/Earthing kits: Weatherproof enclosures: Install in series (in-line)
OVR CME 4 Mount & earth OVR WBX 4, OVR WBX 4/GS
up to 4 protectors For use with a OVR CME 4
DIRTY CLEAN
OVR CME 8 Mount & earth and up to 4 protectors
up to 8 protectors OVR WBX 8, OVR WBX 8/GS
OVR CME 16 Mount & earth For use with a OVR CME 8
up to 16 protectors and up to 8 protectors
OVR CME 32 Mount & earth OVR WBX 16/2/G From line To
up to 32 protectors For use with one or two OVR CME equipment
16 and up to 32 protectors Earth
NOTE: For some data and signal applications with lower current, higher in-line resistance or higher bandwidth requirements, the OVR D or E Series protectors
or the Slim Line OVR SL Series may be more suitable.
5/115
—
Protection and safety
Data & signal protection
OVR H Series
OVR H Series - Technical specification
Electrical specification OVR 06H OVR 15H OVR 30H OVR 50H OVR 110H
ABB order code 7TCA085400R0355 7TCA085400R0357 7TCA085400R0358 7TCA085400R0359 7TCA085400R0356
5
Nominal voltage (1) 6V 15 V 30 V 50 V 110 V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V 11 V/16.7 V 25 V/36.7 V 40 V/56.7 V 93 V/132 V
Current rating (signal) 4A
In-line resistance (per line ±10%) 0.05 Ω
Bandwidth (-3 dB 50 Ω system) 160 KHz 140 KHz 130 KHz 120 KHz 120 KHz
Transient specification OVR 06H OVR 15H OVR 30H OVR 50H OVR 110H
Let-through voltage
(all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 12.0 V 27.5 V 46.0 V 67.0 V 150 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 11.0 V 26.5 V 45.0 V 66.5 V 145 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 10.5 V 25.5 V 43.5 V 65.0 V 140 V
61643-21
5 kV, 10/700 μs (4) 10.8 V 26.2 V 44.3 V 65.8 V 145 V
Maximum surge current
D1 test 10/350 μs – Per signal wire 2.5 kA
to BS EN/EN/IEC – Per pair 5 kA
61643-21
8/20 μs to ITU-T – Per signal wire 10 kA
K.45:2003, IEEE – Per pair 20 kA
C62.41.2:2002
Mechanical specification OVR 06E OVR 15E OVR 30E OVR 50E OVR 110E
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.5 Nm
Conductor size (stranded) 2.5 mm2
Earth connection M6 stud - maximum torque 0.5 Nm
Case material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg
– Packaged (per 10) 0.85 kg
Dimensions See diagram below
54 mm
38 mm
105 mm
M4 clearance
120 mm
19 mm
109 mm
M4 clearance
(1)
ominal voltage (RMS/DC or AC peak)
N
measured at < 10 μA (OVR 15H, OVR 30H,
OVR 50H, OVR 110H) and < 200 μA (OVR 06H)
(2)
Maximum working voltage (RMS/DC or AC peak)
measured at < 5 mA leakage (OVR 15H, OVR 30H,
OVR 50H, OVR 110H) and < 10 mA (OVR 06H)
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/116 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR SL 3-Wire Series
5
Application Installation
Use these protectors for 3-wire systems where installation Connect in series with the data communication or signal line
space is at a premium and large numbers of lines require either near where it enters or leaves the building or close to
protection (e.g. process control, high speed digital the equipment being protected (e.g. within its control
communication equipment or systems with long signal panel). Either way, it must be very close to the system’s
lines). earth star point. Install protectors either within an existing
cabinet/cubicle or in a separate enclosure.
1 3
Max surge current 20kA
Let-through voltage, Up 63V
S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
NOTE: The OVR SL ‘Slim Line’ Series is also available for protection of 2-wire systems up to 110 V, RS 485, RTD and telecommunication applications
(OVR SL Series, OVR SL RS485, OVR SL RTD and OVR SL TN). The OVR SL X Series has approvals for use in hazardous areas.
5/117
—
Protection and safety
Data & signal protection
OVR SL 3-Wire Series
OVR SL 3-Wire Series - Technical specification
Electrical specification OVR SL06/3W OVR SL15/3W OVR SL30/3W OVR SL50/3W OVR SL110/3W
ABB order code 7TCA085400R0328 7TCA085400R0330 7TCA085400R0331 7TCA085400R0332 7TCA085400R0329
5
Nominal voltage (1) 6V 15 V 30 V 50 V 110 V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V 11 V/16.7 V 25 V/36.7 V 40 V/56.7 V 93 V/132 V
Current rating (signal) 500 mA
In-line resistance (per line ±10%) 1.0 Ω
Bandwidth (-3 dB 50 Ω system) 45 MHz
Transient specification OVR SL06/3W OVR SL15/3W OVR SL30/3W OVR SL50/3W OVR SL110/3W
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 36.0 V 38.4 V 63.0 V 90.3 V 185 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 26.2 V 29.4 V 51.3 V 77.2 V 175 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 16.0 V 26.8 V 45.4 V 68.3 V 165 V
61643-21
5 kV, 10/700 μs (4) 17.0 V 27.5 V 46.3 V 69.1 V 170 V
Maximum surge current
D1 test 10/350 μs to – Per signal wire 1.25 kA
BS EN/EN/IEC 61643-21 – Per pair 2.5 kA
8/20 μs to ITU-T – Per signal wire 10 kA
K.45:2003, IEEE – Per pair 20 kA
C62.41.2:2002
Mechanical specification OVR SL06/3W OVR SL15/3W OVR SL30/3W OVR SL50/3W OVR SL110/3W
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.8 Nm
Conductor size (stranded) 4 mm2
Earth connection Via DIN rail or 4 mm2 earth terminal - maximum torque 0.8 Nm
Case material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg
– Packaged (per 10) 0.85 kg
Dimensions See diagram below
104.6 mm
106.5 mm
7 mm 2 S 1 1 S 2 E
(1)
ominal voltage (RMS/DC or AC peak) measured at
N
< 10 μA (OVR SL15/3W, OVR SL30/3W, OVR SL50/3W,
OVR SL110/3W) and < 200 μA (OVR SL06/3W)
(2)
Maximum working voltage (RMS/DC or
AC peak) measured at < 1 mA leakage
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45, Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/118 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR SL LED 4-20 mA Series
5
Application Installation
Use these protectors on 4-20 mA loop systems - ideal where Connect in series with the 4-20 mA current loop either near
installation space is at a premium and large numbers of lines where it enters or leaves the building or close to the
require protection, or for systems with long signal lines. equipment being protected (e.g. within its control panel).
Either way, it must be very close to the system’s earth star
point. Install protectors either within an existing cabinet/
cubicle or in a separate enclosure.
Accessories
Max working voltage, Uc 36.7V
Current rating 750mA
In-line resistance 1.0Ω
1 3
Max surge current 20kA
Let-through voltage, Up 63V
S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
TECHNICAL NOTE: 4-20 mA current loops can serve multiple devices over a long distance. The devices and wiring produce a voltage drop (also known as “loop
drops”) but these do not reduce the 4-20 mA current as long as the power supply voltage is greater than the sum of the voltage drops around the loop at the
maximum signalling current of 20 mA.For design considerations, each OVR SL30L/4-20 device installed within the loop introduces a 1.7 V loop drop.
NOTE: The OVR SL ‘Slim Line’ Series is also available for protection of systems up to 110 V as well as 3-wire, RS 485, RTD & telecommunication
applications (OVR SL/3W, OVR SL RS485, OVR SL RTD & OVR SL TN). The OVR SL X Series has approvals for use in hazardous areas.
5/119
—
Protection and safety
Data & signal protection
OVR SL LED 4-20 mA Series
OVR SL LED 4-20 mA Series - Technical specification
Electrical specification OVR SL30L/4-20
ABB order code 7TCA085400R0371
5
Nominal voltage (1)
30 V
Maximum working voltage Uc (RMS/DC) (2) 25 V/36.7 V
Current rating (signal) (3) 75 mA
In-line resistance (per line ±10%) 1.0 Ω
Series voltage drop (4) 1.7 V
Bandwidth (-3 dB 50 Ω systems) 45 MHz
Transient specification OVR SL30L/4-20
Let-through voltage (all conductors) (5) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to BS EN/EN/IEC 61643-21 63.0 V
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to BS EN/EN/IEC 61643-21 51.3 V
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21 45.4 V
5 kV, 10/700 μs (6) 46.3 V
Maximum surge current
D1 test 10/350 μs to – Per signal wire 1.25 kA
BS EN/EN/IEC 61643-21 – Per pair 2.5 kA
8/20 μs to ITU-T K.45:2003, – Per signal wire 10 kA
IEEE C62.41.2:2002 – Per pair 20 kA
Mechanical specification OVR SL30L/4-20
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.8 Nm
Conductor size (stranded) 4 mm2
Earth connection Via DIN rail or 4 mm2 earth terminal - maximum torque 0.8 Nm
Case material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg
– Packaged (per 10) 0.85 kg
Dimensions See diagram below
104.6 mm
106.5 mm
7 mm 2 S 1 1 S 2 E
(1) N
ominal voltage (RMS/DC or AC
peak) measured at < 10 μA
(2) M
aximum working voltage (RMS/DC or
AC peak) measured at < 1 mA leakage
(3) The minimum current for LED
indicator operation is 2 mA
(4) At 20 mA
(5) T he maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(6) T est to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45, Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/120 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR Q Series
5
Application Installation
Use these protectors where installation space is at Connect in series with the signal or data line either near
a premium and large numbers of lines require protection. where it enters or leaves the building or close to the
equipment being protected. Install in a cabinet/cubicle close
to the system’s earth star point.
S S
S S
S S
S S
From To
line Earth equipment
NOTE: The OVR Q Series is also available for protection of RS 485 and RTD applications (OVR RS485Q, OVR RTDQ). Protectors for individual data and
signal lines are available (OVR D Series and Slim Line OVR SL Series). Alternatively, for individual protectors with higher current
or bandwidth use the OVR E and OVR H Series. For telecommunication applications use OVR TNQ Series.
5/121
—
Protection and safety
Data & signal protection
OVR Q Series
OVR Q Series - Technical specification
Electrical specification OVR 06Q OVR 15Q OVR 30Q OVR 50Q OVR 110Q
ABB order code 7TCA085400R0333 7TCA085400R0340 7TCA085400R0341 7TCA085400R0342 7TCA085400R0343
5
Nominal voltage (1) 6V 15 V 30 V 50 V 110 V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V 13 V/18.8 V 26 V/37.8 V 41 V/57.8 V 93 V/132 V
Current rating (signal) 750 mA 750 mA 750 mA 750 mA 750 mA
In-line resistance (per line ±10%) 1.0 Ω 1.0 Ω 1.0 Ω 1.0 Ω 1.0 Ω
Bandwidth (-3 dB 50 Ω system) 45 MHz 45 MHz 45 MHz 45 MHz 45 MHz
Transient specification OVR 06Q OVR 15Q OVR 30Q OVR 50Q OVR 110Q
Let-through voltage
(all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to BS 15.0 V 28.0 V 53.0 V 84.0 V 188 V
EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 12.5 V 26.5 V 48.0 V 76.0 V 175 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 10.0 V 23.0 V 43.5 V 64.5 V 145 V
61643-21
5 kV, 10/700 μs (4) 10.8 V 26.2 V 44.3 V 65.8 V 150 V
Maximum surge current
D1 test 10/350 μs – Per signal wire 2.5 kA
to BS EN/EN/IEC – Per pair 5 kA
61643-21
8/20 μs to ITU-T – Per signal wire 10 kA
K.45:2003, IEEE – Per pair 20 kA
C62.41.2:2002
Mechanical specification OVR 06Q OVR 15Q OVR 30Q OVR 50Q OVR 110Q
Temperature range -40 to +80 °C
Connection type Pluggable 12 way screw terminal - maximum torque 0.6 Nm
Conductor size (stranded) 2.5 mm2
Earth connection Via DIN rail or M5 threaded hole in base of unit
Case material FR Polymer UL-94 V-0
Weight – Unit 0.1 kg
– Packaged (each) 0.12 kg
– Packaged (per 10) 1.3 kg
Dimensions See diagram below
95 mm
M3 clearance
Depth: 18 mm
87 mm 69 mm
42 mm
(1)
Nominal voltage (RMS/DC or AC peak)
measured at < 5 μA (OVR 15Q, OVR 30Q,
OVR 50Q, OVR 110Q) and < 200 μA (OVR 06Q)
(2)
Maximum working voltage (RMS/DC or
AC peak) measured at < 5 mA leakage
(OVR 15Q, OVR 30Q, OVR 50Q, OVR 110Q)
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45, Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/122 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR RTD Series
5
Installation
Connect in series with the signal line either near where it point. Install protectors either within an existing
enters or leaves the building or close to the equipment being cabinet/cubicle or in a separate enclosure.
protected ensuring it is very close to the system’s earth star
OVR SLRTD/B
Current rating 750mA
In-line resistance 1.0Ω
1 3
Max surge current 20kA
Let-through voltage, Up 63V
From To S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
Weatherproof enclosure:
OVR WBX SLQ (OVR SLRTD and OVR RTD Q)
From To
line Earth equipment
NOTE: For 2-wire or 4-wire RTD applications, use one or two OVR 06D or OVR SL06 protectors respectively.
5/123
—
Protection and safety
Data & signal protection
OVR RTD Series
OVR RTD, RTDQ & SL RTD Series - Technical specification
Electrical specification OVR RTD OVR SL RTD OVR RTDQ
ABB order code 7TCA085400R0313 7TCA085400R0315 7TCA085400R0314
5
Nominal voltage (1)
6V
Maximum working voltage Uc (RMS/DC) (2) 5 V/7.79 V
Current rating (signal) 200 mA 500 mA 700 mA
In-line resistance (per line ±10%) 10 Ω 1.0 Ω 1.0 Ω
Bandwidth (-3 dB 50 Ω system) 800 kHz 1.5 MHz 800 kHz
Transient specification OVR RTD OVR SL RTD OVR RTDQ
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 12.0 V 17.9 V 15.0 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 11.5 V 12.1 V 12.5 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21 10.0 V 11.0 V 10.0 V
5 kV, 10/700 μs (4) 10.5 V 11.3 V 10.5 V
Maximum surge current
D1 test 10/350 μs to – Per signal wire 2.5 kA 1.25 kA 2.5 kA
BS EN/EN/IEC 61643-21 – Per pair 5 kA 2.5 kA 5 kA
8/20 μs to ITU-T K.45:2003, – Per signal wire 10 kA
IEEE C62.41.2:2002 – Per pair 20 kA
Mechanical specification OVR RTD OVR SL RTD OVR RTDQ
Temperature range -40 to +80 °C
Connection type Screw terminal - Screw terminal - Pluggable 12 way screw
max. torque 0.5 Nm max. torque 0.8 Nm terminal
Conductor size (stranded) 2.5 mm2 4 mm2 2.5 mm2
Earth connection M6 stud - max. torque 0.5 Nm Via DIN rail or 4 mm2 earth Via DIN rail or M5 threaded
terminal - max. torque 0.8 Nm hole in base of unit -
max. torque 0.6 Nm
Case Material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg 0.08 kg 0.1 kg
– Packaged (per 10) 0.85 kg 0.85 kg 1.3 kg
Dimensions See diagram below
54 mm
M3 clearance
38 mm
Depth: 18 mm
105 mm 87 mm 69 mm
M4 clearance
42 mm
120 mm
19 mm
109 mm
M4 clearance
OVR SL RTD
(1)
ominal voltage (RMS/DC or AC peak)
N
measured at < 200 μA
(2)
Maximum working voltage (RMS/DC
or AC peak) measured at < 10 mA
104.6 mm
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns 106.5 mm
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/ 7 mm 2 S 1 1 S 2 E
—
Protection and safety
Telecoms & computer line protection
OVR KT & KE Series
5
Application Installation
• For PSTN (e.g POTS, dial-up, lease line, T1/E1, Install protectors on all lines that enter or leave each
*DSL and Broadband) and U interface ISDN lines, use OVR building (including extensions to other buildings). Identify
KT1 (or OVR KT1/PTC) and OVR K10T1 (or OVR K10T1/PTC) the lines requiring protection and plug-in the protector
• Protect single lines with OVR KT1 or OVR KT1/PTC (ensuring the correct orientation) for a series connection.
• Protect all ten lines on a disconnection module with Plug OVR K10T1 or OVR K10T1/PTC directly into each
OVR K10T1 or OVR K10T1/PTC disconnection module requiring protection.
OVR KT1 and OVR KT1/PTC must be installed via the OVR
KE10 earth bar. Clip an OVR KE10 on to the disconnection
module and plug an OVR KT1 or OVR KT1/PTC in to each line
on the module that needs protecting. In the unlikely
situation that the protector is damaged, it will sacrifice
itself and fail short circuit, taking the line out of
commission, indicating it needs replacing and preventing
subsequent transients from damaging equipment.
NOTE: For individual telephone lines and lines at unmanned sites the high performance OVR TN or plug-in OVR TN/JP or OVR TN/RJ11 Series should be used.
For plug-in S/T interface ISDN protection, use the ISDN Series protectors.
5/125
—
Protection and safety
Telecoms & computer line protection
OVR KT & KE Series
OVR KT & KE Series - Technical specification
Electrical specification OVR KT1 OVR KT1/PTC OVR K10T1 OVR K10T1/PTC
ABB order code 7TCA085400R0305 7TCA085400R0306 7TCA085400R0307 7TCA085400R0410
5
Maximum working – line to line 296 V 296 V 296 V 296 V
voltage Uc (1) – line to earth 296 V 296 V 296 V 296 V
Current rating (signal) 300 mA 145 mA 300 mA 145 mA
In-line resistance (per line ±10%) 4.4 Ω
Bandwidth (-3 dB 50 Ω system) 20 MHz 20 MHz 20 MHz 20 MHz
Transient specification OVR KT1 OVR KT1/PTC OVR K10T1 OVR K10T1/PTC
Let-through voltage (all conductors) (2) Up
C2 test 4 kV 1.2/50 μs, – line to line 395 V 395 V 395 V 395 V
2 kA 8/20 μs to BS – line to earth 395 V 395 V 395 V 395 V
EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, – line to line 390 V 390 V 390 V 390 V
0.5 kA 8/20 μs to BS – line to earth 390 V 390 V 390 V 390 V
EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs – line to line 298 V 298 V 298 V 298 V
to BS EN/EN/IEC – line to earth 298 V 298 V 298 V 298 V
61643-21
5 kV, 10/700 μs (3)
– line to line 300 V 300 V 300 V 27 V
– line to earth 300 V 300 V 300 V 80 V
Maximum surge current (4)
D1 test 10/350 μs to – line to line 1 kA
BS EN/EN/IEC – line to earth 2 kA
61643-21
8/20 μs to ITU-T – line to line 5 kA
K.45:2003, IEEE – line to earth 10 kA
C62.41.2:2002
Power Faults specification OVR KT1 OVR KT1/PTC OVR K10T1 OVR K10T1/PTC
Power/Line Cross and Power Induction - tests to: ITU-T (formerly CCITT) K.20, K.21 and
K.45, Telcordia GR-1089-CORE, Issue 2:2002, UL 60950/IEC 950
Power/line cross – 110/230 Vac – 110/230 Vac
(15 min) (15 min)
Power induction – 600 V, 1 A (0.2 sec) – 600 V, 1 A
Mechanical specification OVR KT1, OVR KT1/PTC OVR K10T1, OVR K10T1/PTC OVR KE10
Temperature range -40 to +80 °C –
Connection type To LSA-PLUS disconnection modules (BT part number 237A) –
Earth connection Via OVR KE10 earth bar Via integral earth clip/external M4 bush –
Material FR Polymer UL-94 V-0 Stainless Steel
Weight – Unit 0.01 kg 0.10 kg 0.01 kg
– Packaged 0.12 kg (per 10) 0.12 kg 0.10 kg (per 10)
Dimensions See diagram below
22 mm
110 mm
40 mm
(1)
aximum working voltage (DC or
M 40 mm
AC peak) at 10 μA for OVR KT1, OVR KT1/ 59 mm 59 mm 20 mm
PTC, OVR K10T1, OVR K10T1/PTC
(2)
The maximum transient voltage let-through of the
Depth: 21 mm
protector throughout the test (±10%), line to line & 9.5 mm 110 mm 22 mm
line to earth, both polarities. Response time < 10 ns
(3)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
(4)
The installation and connections external to the
protector may limit the capability of the protector
5/126 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Telecoms & computer line protection
OVR TN/RJ11 & ISDN/RJ45 Series
5
Application
• For PSTN (e.g. POTS, dial-up, lease line, T1/E1, *DSL and • For S/T interface ISDN lines with RJ45 connections protect
Broadband) use TN/RJ11 the middle 4 (of 8) conductors (paired 3&6, 4&5) with OVR
• OVR TN/RJ11… are suitable for use on telephone lines with ISDN/RJ45-4/8, or all 8 (outside pairs 1&2, 7&8) with OVR
a maximum (or ringing) voltage of up to 296 Volts ISDN/RJ45-8/8
• For telephone lines with RJ11 connections protect the
middle 2 (of 6) conductors with OVR TN/RJ11-2/6, the For further information on RJ45 ISDN applications, see sep-
middle 4 (of 6) with OVR TN/RJ11-4/6 or all 6 with arate Application Note OVR AN002 and for global telephony
OVR TN/RJ11-6/6 applications, see separate Application Note
• For S/T interface ISDN lines, use OVR ISDN/RJ45-4/8 and OVR AN005 (contact us for a copy).
OVR ISDN/RJ45-8/8
Installation
Connect in series with the telephone or ISDN line. These
Accessories
units are usually installed close to the equipment being
OVR CAT5e/UTP-1
protected and within a short distance of a good electrical 1 metre cable with RJ45 connections
earth.
To From To From
phone equipment ISDN equipment
socket Earth line Earth
NOTE: For non-ISDN wire-in applications the high performance OVR TN, OVR SLTN or OVR TNQ can be used.
Protect PBX telephone exchanges and other equipment with LSA-PLUS connections using OVR KT series.
5/127
—
Protection and safety
Telecoms & computer line protection
OVR TN/RJ11 & ISDN/RJ45 Series
OVR TN/RJ11 & ISDN/RJ45 Series - Technical specification
Electrical specification OVR TN/ OVR TN/ OVR TN/ OVR ISDN/ OVR ISDN/
RJ11-2/6 RJ11-4/6 RJ11-6/6 RJ45-4/8 RJ45-8/8
5
ABB order code 7TCA085400R0337 7TCA085400R0338 7TCA085400R0339 7TCA085460R0359 7TCA085460R0360
Nominal voltage 296 V 296 V 296 V 5V 5 V/58 V (2)
Maximum working voltage Uc (1) 296 V 296 V 296 V 58 V 58 V
Current rating (signal) 300 mA
In-line resistance (per line ±10%) 4.4 Ω
Bandwidth (-3 dB 50 Ω system) 20 MHz 20 MHz 20 MHz 19 MHz 19 MHz
Transient specification OVR TN/ OVR TN/ OVR TN/ OVR ISDN/ OVR ISDN/
RJ11-2/6 RJ11-4/6 RJ11-6/6 RJ45-4/8 RJ45-8/8
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, – line to line 395 V 395 V 395 V 28 V 28 V/88 V (5)
2 kA 8/20 μs to – line to earth 395 V 395 V 395 V 88 V 88 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, – line to line 390 V 390 V 390 V 23 V 23 V/63 V (5)
0.5 kA 8/20 μs to – line to earth 390 V 390 V 390 V 63 V 63 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs – line to line 298 V 298 V 298 V 26 V 26 V/65 V (5)
to BS EN/EN/IEC – line to earth 298 V 298 V 298 V 65 V 65 V
61643-21
5 kV, 10/700 μs (4) – line to line 300 V 300 V 300 V 27 V 27 V/80 V (5)
– line to earth 300 V 300 V 300 V 80 V 80 V
Maximum surge current (6)
D1 test 10/350 μs to 1 kA
BS EN/EN/IEC 61643-21
8/20 μs to ITU-T K.45:2003, 10 kA
IEEE C62.41.2:2002:
Mechanical specification OVR TN/ OVR TN/ OVR TN/ OVR ISDN/ OVR ISDN/
RJ11-2/6 RJ11-4/6 RJ11-6/6 RJ45-4/8 RJ45-8/8
Temperature range -40 to +80 °C
Connection type RJ11 plug RJ11 plug RJ11 plug RJ45 plug RJ45 plug
and socket and socket and socket and socket and socket
Earth connection M4/DIN rail
Case Material FR Polymer UL-94 V-0
Weight – Unit 0.15 kg
– Packaged 0.2 kg
Dimensions See diagram below
106 mm106 mm
OVR ISDN/RJ45-4/8,
OVR ISDN/RJ45-4/8,
8/8 8/8
54 mm 54 mm60 mm 60 mm
cable length:
cable length:
0.5 m 0.5 m
49 mm 49 mm
(1)
aximum working voltage (DC or AC peak)
M
measured at < 10 μA leakage for OVR TN/RJ11 OVR TN/RJ11-2/6,
OVR TN/RJ11-2/6,
4/6, 6/6 4/6, 6/6
cable length:
cable length:
1m 1m
products and < 5 μA for OVR ISDN/RJ45 products Depth: Depth:
24 mm 24 mm
(2)
Maximum working voltage is 5 V for pairs Fixing centres
Fixing centres
49 x 54 49
mm,x 54
M3mm,
clearance
M3 clearance
3/6 & 4/5, and 58 V for pairs 1/2 & 7/8
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia GR-
1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
(5)
The first let-through voltage value is for pairs
3/4 & 5/6, and the second value is for pairs 1/2 & 7/8
(6)
The installation and connectors external to the
protector may limit the capability of the protector
5/128 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR TN, TNQ & SL TN Series
5
Accessories
Application
Replacement module for OVR SL TN: If protectors cannot be incorporated
Connect in series with the signal line either near where it OVR SLTN/M within an existing panel or enclosure,
enters or leaves the building or close to the equipment being Standard module replacement OVR WBX enclosures are available
for up to 4, 8, 16 or 32 protectors
protected ensuring it is very close to the system’s earth star Combined Mounting/Earthing kits for and their associated OVR CME kit.
point. Install protectors either within an existing OVR RS485:
OVR CME 4 For up to 4 x OVR TN Weatherproof enclosure:
cabinet/cubicle or in a separate enclosure. OVR CME 8 For up to 8 x OVR TN OVR WBX SLQ (OVR SLTN and OVR TNQ)
OVR CME 16 For up to 16 x OVR TN
OVR CME 32 For up to 32 x OVR TN
OVR TN installed in series OVR SL TN installed in series OVR TNQ installed in series (in-line)
1 3
Max surge current 20kA
Let-through voltage, Up 63V
OVR TNQ
From To
Furse
S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
line equipment
Earth 2 4
From To
line Earth equipment
From
From line
line Toequipment
To equipment
Earth
Earth
NOTE: The OVR KT Series is also available for telecommunications application using LSA-PLUS disconnection modules.
Plug-in solutions are also available for RJ11 connections (see OVR TN RJ11 Series).
5/129
—
Protection and safety
Data & signal protection
OVR TN, TNQ & SL TN Series
OVR TN, TNQ & SL TN Series - Technical specification
Electrical specification OVR TN OVR SL TN, OVR SL TNL OVR TNQ
ABB order code 7TCA085400R0345 7TCA085400R0323, 7TCA085400R0418 7TCA085400R0344
5
Nominal voltage (1)
–
Maximum working voltage Uc (RMS/DC) (2) –/296 V
Current rating (signal) 300 mA
In-line resistance (per line ±10%) 4.4 Ω
Bandwidth (-3 dB 50 Ω system) 20 MHz
Transient specification OVR TN OVR SL TN , OVR SL TNL OVR TNQ
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 395 V
BS EN/EN/IEC 61643-21
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to 390 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21 298 V
5 kV, 10/700 μs (4) 300 V
Maximum surge current
D1 test 10/350 μs to – Per signal wire 2.5 kA 1.25 kA 2.5 kA
BS EN/EN/IEC 61643-21 – Per pair 5 kA 2.5 kA 5 kA
8/20 μs to ITU-T K.45:2003, – Per signal wire 10 kA
IEEE C62.41.2:2002 – Per pair 20 kA
Mechanical specification OVR TN OVR SL TN , OVR SL TNL OVR TNQ
Temperature range -40 to +80 °C
Connection type Screw terminal - Screw terminal - max. torque 0.8 N Pluggable 12 way screw
max. torque 0.5 Nm terminal
Conductor size (stranded) 2.5 mm2 4 mm2 2.5 mm2
Earth connection M6 stud Via DIN rail or 4 mm2 earth terminal - Via DIN rail or M5
max. torque 0.8 Nm threaded hole in base
of unit
Case Material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg 0.1 kg
– Packaged (per 10) 0.85 kg 1.3 kg
Dimensions See diagram below
54 mm
M3 clearance
38 mm
Depth: 18 mm
105 mm 87 mm 69 mm
M4 clearance
42 mm
120 mm
19 mm
109 mm
M4 clearance OVR SL TN
(1)
ominal voltage (RMS/DC or AC
N
peak) measured at < 10 μA
(2)
Maximum working voltage (RMS/DC 104.6 mm
or AC peak) measured at < 5 mA
(3)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line & 106.5 mm
line to earth, both polarities. Response time < 10 ns
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
7 mm 2 S 1 1 S 2 E
—
Protection and safety
Telecom & computer line protection
OVR Cat-5 & Cat-6 Series
5
Application
Use these protectors on network cables that travel between • To protect up to 100baseT Power over Ethernet (PoE)
buildings to prevent damage to equipment, e.g. computers, networks with Cat-5/Cat-5e use OVR Cat-5e/PoE
servers, repeaters and hubs. Suitable for computer networks • To protect up to 1000baseT/10GbaseT Power over
up to Cat-6A cabling. Ethernet (PoE) networks with Cat-6/Cat-6A cabling use
• To protect up to 100baseT networks with Cat-5/Cat-5e OVR Cat-6/PoE
cabling use OVR Cat-5e
• To protect up to 1000baseT/10GbaseT networks with For further application information, see separate
Cat-6/Cat-6A cabling use OVR Cat-6 Application Note OVR AN004 (contact us for a copy).
Installation
Connect in series with the network cable, either:
• Near to where it enters or leaves the building, or
• As it enters the network hub, or
• Close to the equipment being protected Accessories
OVR CAT5e/UTP-1 OVR CAT6/STP-2
This should be close to the system’s earth star point
1 metre cable with unshielded 2 metre screened cable with
(to enable a good connection to earth). RJ45 connections shielded RJ45 connections
NOTE: To protect datacomms systems based on twisted pairs, use the OVR D, E or H Series. Local protection for networked equipment is also available.
5/131
—
Protection and safety
Telecom & computer line protection
OVR Cat-5 & Cat-6 Series
OVR Cat-5 & Cat-6 Series - Technical specification
Electrical Specification OVR Cat-5e OVR Cat-5e/PoE OVR Cat-6 OVR Cat-6/PoE
ABB order code 7TCA085400R0289 7TCA085400R0290 7TCA085400R0291 7TCA085400R0292
5
Maximum working – data (2)
5V
voltage Uc (1) – power (3) – 58 V – 58 V
Current rating 300 mA 600 mA (4) 300 mA 600 mA (4)
In-line resistance – data (2) 1.5 Ω
(per line ±25%) – power – 1.5 Ω – –
Maximum data rate 100 Mbps 100 Mbps 1000 Mbps 1000 Mbps
Networking standards 10/100baseT 10/100baseT 10/100/1000/ 10/100/1000/
10GbaseT 10GbaseT
TIA Cat-5e TIA Cat-5/PoE TIA Cat-6 TIA Cat-6
IEEE 802.3i IEEE 802.3i IEEE 802.3i IEEE 802.3i
IEEE 802.3u IEEE 802.3u IEEE 802.3u IEEE 802.3u
– IEEE 802.3af IEEE 802.3ab IEEE 802.3ab
– IEEE 802.3at IEEE 802.3an IEEE 802.3an
– – – IEEE 802.3af
– – – IEEE 802.3at
Transient specification OVR Cat-5e OVR Cat-5e/PoE OVR Cat-6 OVR Cat-6/PoE
Let-through voltage (all conductors) (5) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs – line to line 120 V 120 V/116 V (8) 120 V 120 V/116 V (8)
to BS EN/EN/IEC 61643-21 – line to earth (6) 700 V
C1 test 1 kV, 1.2/50 μs, 0.5 kA – line to line 74 V 74 V/95 V (8) 74 V 74 V/95 V (8)
8/20 μs to BS EN/EN/IEC 61643-21 – line to earth (6)
600 V
B2 test 4 kV 10/700 μs to – line to line 21 V 21 V/87 V (8) 21 V 21 V/87 V (8)
BS EN/EN/IEC 61643-21 – line to earth(6) 550 V
5 kV, 10/700 μs (7) – line to line 25 V 25 V/90 V (8) 25 V 25 V/90 V (8)
– line to earth (6) 600 V
Maximum surge current (9)
D1 test 10/350 μs to BS EN/EN/IEC 61643-21 1 kA
8/20 μs to ITU-T K.45:2003, IEEE C62.41.2:2002 10 kA
Mechanical specification OVR Cat-5e, OVR Cat-6,
OVR Cat-5e/PoE OVR Cat-6/PoE
Temperature range -40 to +80 °C
Connection type RJ45 sockets
Cable (supplied) 0.5 m Cat-5e UTP 0.5 m Cat-6 STP
patch lead patch lead
Earth connection M4/DIN rail
Case Material FR Polymer UL-94 V-0
Weight – Unit 0.15 kg
– Packaged 0.2 kg
Dimensions See diagram below
106 mm
(1)
aximum working voltage (DC or AC
M
peak) measured at 1 mA leakage (6)
he interfaces used in network systems incorporate
T
(2)
Data pairs 1/2 and 3/6 are protected an isolation transformer that inherently 106 mm
as standard. Pairs 4/5 and 7/8 are provides an inbuilt immunity to transients
106 mm
also protected on Cat-6 barriers between line and earth of 1,500 Volts or more 54 mm 60 mm Depth: 24 m
(3)
PoE protectors transmit power (7)
Test to IEC 61000-4-5:2014, ITU-T (formerly 49 mm Fixing centr
Mode A and Mode B power CCITT) K.20, K.21 and K.45,Telcordia 49 x 54 mm
(4)
B ased on 30W of transmitted PSE GR-1089-CORE, Issue 6:2011, ANSI TIA/EIA/ M3 clearanc
54 mm 60 mm Depth: 24 mm
power, to IEEE 802.3at. IS-968-A:2005 (formerly FCC Part 68).
(5)
The maximum transient voltage let-through (8)
The first number is for the data pair, with 5449
mmmm 60 mm Depth: 24 mm Fixing centres
of the protector throughout the test the second number for the power pair 49 x 54 mm,
49 mm Fixing centres M3 clearance
(±10%), line to line & line to earth. Response (9)
The installation and connectors may 49 x 54 mm,
time <10 ns (on all protected pairs) limit the capability of the protector M3 clearance
5/132 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Data & signal protection
OVR RS485, RS485Q & SL RS485 Series
5
point. Install protectors either within an existing Combined Mounting/Earthing kits for Weatherproof enclosure:
cabinet/cubicle or in a separate enclosure. OVR RS485: OVR WBX SLQ (OVR SL RS485 and
OVR CME 4 For up to 4 x OVR RS485 OVR RS485Q)
OVR CME 8 For up to 8 x OVR RS485
OVR CME 16 For up to 16 x OVR RS485
OVR CME 32 For up to 32 x OVR RS485
OVR RS485 installed in series OVR SL RS485 installed in series OVR RS485Q installed in series (in-line)
1 3
Max surge current 20kA
Let-through voltage, Up 63V
From To
Furse
S
Wilford Road,
S
Nottingham,
NG2 1EB, UK
line equipment
Earth 2 4
From To
line Earth equipment
From
From line
line Toequipment
To equipment
Earth
Earth
NOTE: The OVR SL ‘Slim Line’ Series is also available for protection of 3-wire and RTD applications (OVR SL/3W & OVR SL RTD).
The OVR SL X Series has approvals for use in hazardous areas.
5/133
—
Protection and safety
Data & signal protection
OVR RS485, RS485Q & SL RS485 Series
OVR RS485, RS485Q & SL RS485 Series - Technical specification
Electrical specification OVR RS485 OVR SL RS485 OVR RS485Q
ABB order code 7TCA085400R0311 7TCA085400R0310 7TCA085400R0312
5
Nominal voltage (1)
15 V
Maximum working voltage Uc (RMS/DC) (2) 11 V/16.7 V
Current rating (signal) 300 mA
In-line resistance (per line ±10%) 1Ω
Bandwidth (-3 dB 50 Ω system) 45 MHz
Transient specification OVR RS485 OVR SL RS485 OVR RS485Q
Let-through voltage (all conductors) (3) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to BS EN/EN/IEC 61643-21 55.0 V
C1 test 1 kV, 1.2/50 μs, 0.5 kA 8/20 μs to BS EN/EN/IEC 61643-21 42.0 V
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21 27.2 V
5 kV, 10/700 μs (4)
28.2 V
Maximum surge current
D1 test 10/350 μs to – Per signal wire 2.5 kA 1.25 kA 2.5 kA
BS EN/EN/IEC 61643-21 – Per pair 5 kA 2.5 kA 5 kA
8/20 μs to ITU-T K.45:2003, – Per signal wire 10 kA
IEEE C62.41.2:2002 – Per pair 20 kA
Mechanical specification OVR RS485 OVR SL RS485 OVR RS485Q
Temperature range -40 to +80 °C
Connection type Screw terminal - Screw terminal - Pluggable 12 way screw
max. torque 0.5 Nm max. torque 0.8 N terminal
Conductor size (stranded) 2.5 mm2 4 mm2 2.5 mm2
Earth connection M6 stud Via DIN rail or 4 mm 2
Via DIN rail or M5
earth terminal - threaded hole in base of
max. torque 0.8 Nm unit
Case Material FR Polymer UL-94 V-0
Weight – Unit 0.08 kg 0.1 kg
– Packaged (per 10) 0.85 kg 1.3 kg
Dimensions See diagram below
54 mm
M3 clearance
38 mm
Depth: 18 mm
105 mm 87 mm 69 mm
M4 clearance
42 mm
120 mm
19 mm
109 mm
M4 clearance
OVR SL RS485
(1)
ominal voltage (RMS/DC or
N
AC peak) measured at < 10 μA 104.6 mm
(2)
Maximum working voltage (RMS/DC
or AC peak) measured at < 5 mA
(3)
The maximum transient voltage let-through of the 106.5 mm
protector throughout the test (±10%), line to line &
line to earth, both polarities. Response time < 10 ns
7 mm 2 S 1 1 S 2 E
(4)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/134 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Specific systems protection
OVR RF Series
5
Application Installation
Use on coaxial cables to protect RF transmitter and receiver In a building, connect in series with the coaxial cable near
systems, including electronics located at the antenna where it enters or leaves the structure, or close to the
or dish. Typical examples include cell sites, military equipment being protected. This should be as close as
communications, satellite earth stations, pager systems possible to the system’s earth star point (to enable a good
and emergency services communications systems. connection to earth). On a mast, connect in series with the
coaxial cable near the antenna/dish being protected. Install
in a radio communications room, an existing cabinet or
a suitable enclosure.
NOTE: These protectors are based on a continuous transmission line with a GDT connected between this line and screen/earth, and are suited for applications where DC
is required to pass to the equipment. OVR CCTV/B and OVR CCTV/T are suitable for use on coaxial (or twisted pair) CCTV lines.
For coaxial CATV lines, use the OVR CATV/F.
5/135
—
Protection and safety
Specific systems protection
OVR RF Series
OVR RF Series - Technical specification
Electrical specification OVR RF 111421 OVR RF AA1421 OVR RF 441421
Gas Discharge Tube voltage 350 V
5
Maximum working voltage Uc (RMS) 200 V
Characteristic impedance 50 Ω
Bandwidth DC-2.7 GHz
Voltage standing wave ratio ≤ 1.1
Insertion loss over bandwidth ≤ 0.1 dB
Maximum power (1) 650 W
Transient specification OVR RF 111421 OVR RF AA1421 OVR RF 441421
Let-through voltage (all conductors) (2) Up
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to < 800 V
BS EN/EN/IEC 61643-21
C1 test 1 kV 1.2/50 μs, 0.5 kA 8/20 μs to < 650 V
BS EN/EN/IEC 61643-21
B2 test 4 kV 10/700 μs to BS EN/EN/IEC 61643-21 < 550 V
5 kV, 10/700 μs (3) < 580 V
Maximum surge current (4)
D1 test 10/350 μs to BS EN/EN/IEC 61643-21 2.5 kA
8/20 μs to ITU-T K.45:2003, IEEE C62.41.2:2002 20 kA
Mechanical specification OVR RF 111421 OVR RF AA1421 OVR RF 441421
ABB order code 7TCA085450R0065 7TCA085450R0063 7TCA085450R0066
Temperature range -40 to +80 °C 24 mm
24 mm
Connection type N female 7⁄16 DIN female BNC female
Conductor size (stranded) Via mounting fixtures 40 mm
40 mm 17.3 mm
Case Material Aluminium body, nickel plated. Brass connectors, white bronze plated
17.3 mm
58 mm
Weight – Unit 120 g 190 g 90 g
24 mm 58 mm
– Packaged 140 g 210 g 110 g 24 mm
—
Protection and safety
Specific systems protection
OVR CCTV Series
5
Application Installation
Use these protectors on the video cable to outdoor CCTV Connect in series with the CCTV cable in a convenient place
cameras and central control and monitoring equipment. close to the equipment being protected. For outdoor CCTV
cameras, protectors should be mounted in the junction box,
or in a separate enclosure, close to the camera. Protect
central control and monitoring equipment inside the
building by installing protectors on all incoming or outgoing
lines, either:
a) near where they enter or leave the building, or
b) close to the equipment being protected (or actually within
its control panel).
Accessories
When CCTV protectors are installed in groups,
Series connection for OVR CCTV/B Series connection for OVR CCTV/T
or alongside protectors for signal and mains
power lines, these can be mounted and earthed
simultaneously on a OVR CME kit. An OVR CME 4 DIRTY CLEAN DIRTY CLEAN
will accommodate the video, telemetry and power
protectors to a camera. If protectors cannot be
incorporated within an existing panel or enclosure,
OVR WBX enclosures are available for up to 4, 8, From line To equipment From line To
16 or 32 protectors and their associated OVR CME
kit. The OVR WBX 4/GS is a secure IP66 enclosure Earth Earth equipment
suitable for a OVR CME 4 and associated protectors.
NOTE: Camera telemetry or control lines should be protected with a suitable Lightning Barrier from the OVR D or E Series.
Protectors for the power supply to individual cameras (e.g. OVR 240-16A) and the mains supply to the control room are available.
For coaxial RF (OVR RF Series) cable protectors and CATV systems (OVR CATV/F) are also available.
5/137
—
Protection and safety
Specific systems protection
OVR CCTV Series
OVR CCTV Series - Technical specification
Electrical specification OVR OVR CCTV/ OVR CCTV/ OVR CCTV/ OVR OVR OVR CCTV/ OVR CCTV/
CCTV/B B-15V B-30V B-50V CCTV/T CCTV/T-15V T-30V T-50V
5
ABB order code 7TCA085400R0296 7TCA085400R0297 7TCA085400R0299 7TCA085400R0300 7TCA085400R0301 7TCA085400R0302 7TCA085400R0298 7TCA085400R0303
CCTV/B CCTV/T
54 mm 54 mm 54 mm
38 mm 38 mm 38 mm 38 mm
(1)
ominal voltage (DC or AC peak)
N
measured at < 10 μA leakage 105 mm 105 mm 105 mm
(2)
Maximum working voltage M4 (DC or
clearance M4 clearance M4 clearance
AC peak) measured at 5 mA leakage
(3)
C apacitance < 30 pF 120 mm 144 mm 120 mm
(4)
The maximum transient voltage let-through of the
protector throughout the test (±10%), line to line
19 mm 19 mm
& line to earth. Screen to earth let-through voltage
will be up to 600 V (with 5 kV 10/700 test), when
109 mm 109 mm 109 mm
protector is configured forM4 use with non-earthed
clearance M4 clearance M4 clearance
or isolated screen systems. Response time < 10 ns
(5)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
(6)
The installation and connectors external to the
protector may limit the capability of the protector
5/138 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Mains power protection
OVR 240-16A
5
Combined Type 2 and 3 tested protector (to BS EN 61643) for use on low
current (up to 16 A) single phase systems to protect connected electronic
equipment from transient overvoltages on the mains supply, e.g. CCTV systems,
fire/intruder alarm panels.
Application Installation
Use these protectors on low current mains power supplies, Connect in-line with the power supply usually either within
e.g. CCTV cameras, alarm panels and telemetry equipment. the equipment panel (or for CCTV cameras, in an enclosure
close by), or on the fused connection that supplies
equipment. To protect equipment inside a building from
transients entering on an outgoing feed (e.g. to CCTV
cameras or to site lighting) the protector should be installed
as close to where the cable leaves the building as possible.
Protectors should be installed either within an existing
cabinet/cubicle or in a separate enclosure.
Earth
DIRTY CLEAN
From To
line equipment
5/139
—
Protection and safety
Mains power protection
OVR 240-16A
OVR 240-16A - Technical specification
Electrical specification OVR 240-16A
ABB order code 7TCA085460R0361
5
Nominal voltage - Phase-Neutral Uo (RMS) 240 V
Maximum voltage - Phase-Neutral Uc (RMS) 280 V
Working voltage (RMS) 200-280 V
Frequency range 47-63 Hz
Current rating (supply) 16 A or less
Max. back-up fuse (see installation instructions) ≤ 16 A
Leakage current (to earth) < 0.5 mA
Transient specification OVR 240-16A
Type 2 (BS EN/EN), Class II (IEC)
Nominal discharge current 8/20 μs (per mode) In 5 kA
Let-through voltage Up at In (1)
750 V
Maximum discharge current Imax (per mode) (2) 10 kA
Type 3 (BS EN/EN), Class III (IEC)
Let-through voltage at Uoc of 6 kV 1.2/50 μs and 600 V
Isc of 3 kA 8/20 μs (per mode) (1, 3)
Electrical specification OVR 240-16A
Temperature range -40 to +80 °C
Connection type Screw terminal - maximum torque 0.5 Nm
Conductor size (stranded) 4 mm2
Earth connection Via M6 stud or earth terminal -maximum torque 0.5 Nm
Degree of protection (IEC 60529) IP20
Case material Steel
Weight – Unit 0.23 kg
– Packaged 0.25 kg
Dimensions See diagrams below
109 mm centrally 54 mm
38 mm M4 clearance 26 mm 39 mm
105 mm
M3 clearance 120 mm
120 mm
Depth:
56 mm
108 x 50 mm
80 mm
M4 clearance
25 mm max.
25 mm
(1)
he maximum transient voltage let-through of
T
the protector throughout the test (±10%), phase
to neutral, phase to earth and neutral to earth
(2)
The electrical system, external to the unit,
may constrain the actual current rating
achieved in a particular installation
(3)
Combination wave test within IEC/BS EN 61643,
IEEE C62.41-2002 Location Cats C1 & B3, SS
555:2010, AS/NZS 1768-2007, UL 1449 mains wire-in
5/140 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Specific systems protection
OVR TV Series
5
Installation
Connect in series with the coaxial cable either near where it
enters or leaves each building or close to equipment
being protected.
From
line
Earth DIRTY
NOTE: Protectors for coaxial (or twisted pair) CCTV Lines are available. For coaxial RF lines, use the OVR RF Series. Transients can also be conduced into
TV systems via the mains power supplies - use suitable OVR mains protection.
5/141
—
Specific systems
Protection and safetyprotection
ESP TV systems
Specific Seriesprotection
OVR TV Series
OVR TV Series - Technical specification
Electrical specification OVR CATV/F OVR MATV/F OVR SMATV/F OVR TV/F OVR TV/EURO
ABB order code 7TCA085400R0293 7TCA085400R0308 7TCA085400R0336 7TCA085400R0335 7TCA085400R0334
5
ESP TV Series - Technical specification
Maximum working voltage(1) 140 V 18.9 V 18.9 V 6.4 V
Electrical specification ESP CATV/F ESP MATV/F ESP SMATV/F ESP TV/F ESP TV/EURO6.4
Maximum operating current 4A 800 mA 800 mA 300 mA 300 mA
ABB order code 7TCA085400R0122 7TCA085450R0000 7TCA085450R0026 7TCA085450R0028 7TCA085450R0027
Characteristic impedance 75 Ω
Maximum working voltage (1)
140 V 18.9 V 18.9 V 6.4 V 6.4 V
Bandwidth 5-860 MHz 5-3224 MHz 860-3224 MHz 5-860 MHz 5-860 MHz
Maximum operating current 4A 800 mA 800 mA 300 mA 300 mA
Insertion loss – 5-860 MHz < 0.5 dB < 0.3 dB – < 0.3 dB < 0.3 dB
Characteristic impedance 75 Ω
– 860-2150 MHz – < 1.5 dB < 1.5 dB – –
Bandwidth 5-860 MHz 5-2450 MHz 860-2450 MHz 5-860 MHz 5-860 MHz
– 2150-3224 MHz – < 2.2 dB < 2.2 dB – –
Insertion loss: – 5-860 MHz < 0.5 dB < 0.3 dB – < 0.3 dB < 0.3 dB
Return loss (VSWR) – 5-860 MHz > 20 dB (< 1.2:1) > 32 dB (< 1.05:1) – > 32 dB (< 1.05:1) > 32 dB (< 1.05:1)
– 860-2150 MHz – < 1.5 dB < 1.5 dB – –
– 860-2150 MHzMHz –
– 2150-2450 > 20<dB (<dB
2.2 1.2:1) <>2.2
20 dB
dB (< 1.2:1) – – –
– –
– 2150-3224 MHz – < 2.2 dB < 2.2 dB – –
Return loss (VSWR): – 5-860 MHz > 20 dB (< 1.2:1) > 32 dB (< 1.05:1) – > 32 dB (< 1.05:1) > 32 dB (< 1.05:1)
Transient specification OVR CATV/F OVR MATV/F OVR SMATV/F OVR TV/F OVR TV/EURO
– 860-2150 MHz – > 20 dB (< 1.2:1) > 20 dB (< 1.2:1) – –
Let-through voltage (all
– conductors)(2)
2150-2450 MHzUp < 2.2 dB < 2.2 dB
– – –
C2 test 4 kV 1.2/50 μs, 2 kA 8/20 μs to 270 V 70 V 70 V 65 V 65 V
Transient specification ESP CATV/F ESP MATV/F ESP SMATV/F ESP TV/F ESP TV/EURO
BS EN/EN/IEC 61643-21
Let-through voltage (all conductors) Up (2)
C1 test 1 kV 1.2/50 μs, 0.5 kA 8/20 μs to 265 V 60 V 60 V 50 V 50 V
C2 test 4 kV 1.2/5061643-21
BS EN/EN/IEC μs, 2 kA 8/20 μs to
BS B2
EN/EN/IEC
test 4 kV 61643-21
10/700 μs to BS EN/EN/IEC 245 V 270 V 45 V70 V 70
45VV 65 V 30 V 65 V 30 V
61643-21
C1 test 1 kV 1.2/50 μs, 0.5 kA 8/20 μs to
BS 5 kV, 10/70061643-21
EN/EN/IEC μs(3) 250 V 265 V 50 V60 V 50VV
60 50 V 35 V 50 V 35 V
Maximum
B2 test surge μs
4 kV 10/700 current
to BS EN/EN/IEC 61643-21 245 V 45 V 45 V 30 V 30 V
8/20 μs to
5 kV, 10/700 μsITU-T
(3) K.45:2003, IEEE 3 kA 250 V 50 V 50 V 35 V 35 V
C62.41.2:2002
Maximum surge current
D1 test 10/350 μs to BS EN/EN/IEC 500 A 750 A 750 A 750 A 750 A
8/2061643-21
μs to ITU-T K.45:2003, IEEE C62.41.2:2002 3 kA
D1 test 10/350 specification
Mechanical μs to BS EN/EN/IEC 61643-21 500 A
OVR CATV/F OVR 750 A
MATV/F 750
OVRA SMATV/F 750 A OVR TV/F 750 A OVR TV/EURO
Mechanical specification
Temperature range ESP
-40 to +80 ºCCATV/F ESP MATV/F ESP SMATV/F ESP TV/F ESP TV/EURO
Temperature range
Connection type F female -40 to +80 ºC -40 to +80 ºC
Euro-TV
Connection type
Earth connection ~ 9.5 mm F(3⁄8”)
female Euro-TV
Earth connection diameter~earth stud
9.5 mm ( 3⁄ 8”) diameter earth stud ~ 9.5 mm ( 3⁄8”) diameter earth stud
Case
Case Material
Material Diecast Diecast Diecast
Weight
Weight: – Unit – Unit 0.14 kg 0.14 kg 0.14 kg
– Packaged – Packaged 0.15 kg 0.15 kg 0.15 kg
Dimensions
Dimensions See diagram below below
See diagram
(1)
Maximum working voltage (DC or AC peak) measured at
< 5 μA (ESP CATV/F) and < 50 mA (ESP MATV/F,
ESP SMATV/F, ESP TV/EURO, ESP TV/F)
75 mm
(2)
The maximum transient voltage let-through of the protector
throughout the test (±10%), line to line & line to earth.
Response time < 10 ns
(3)
Test to IEC 61000-4-5:2006, ITU-T (formerly CCITT) K.20,
K.21 and K.45,Telcordia GR-1089-CORE, Issue 2:2002,
ANSI TIA/EIA/IS-968-A:2002 (formerly FCC Part 68)
M4 clearance holes,
58 mm
Depth = 23 mm
64.5 mm
(1)
Maximum working voltage (DC or AC
peak) measured at < 5 μA (OVR CATV/F)
and < 50 mA (OVR MATV/F, OVR SMATV/F,
OVR TV/EURO, OVR TV/F)
(2)
The maximum transient voltage let-through
of the protector throughout the test (±10%)
line to earth. Response time < 10 ns
(3)
Test to IEC 61000-4-5:2006, ITU-T (formerly
CCITT) K.20, K.21 and K.45,Telcordia
GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/
IS-968-A:2002 (formerly FCC Part 68)
5/142 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Protector accessories
OVR WBX Series
with grey base and either a see-through or grey (part number/G or/GS) lid.
Application
Use OVR WBX enclosures when your OVR protector(s) can’t be installed within the existing
equipment panel or enclosure and for added protection in damp and dirty environments.
Installation
The protector(s), or OVR CME kit, are mounted on the metal base plate, which in turn mounts in the enclosure.
OVR WBX 4 OVR WBX 8 OVR WBX 16/2/G OVR WBX SLQ
OVR WBX 4/GS OVR WBX 8/GS OVR WBX SLQ/G
ABB Order Code 7TCA085410R0048 7TCA085410R0050 7TCA085410R0047 7TCA085400R0326
7TCA085410R0049 7TCA085410R0051 7TCA085400R0327
Weight – Unit 0.9 kg 1.3 kg 6.4 kg 0.7 kg
– Packaged 0.95 kg 1.35kg 7.6 kg 1.0 kg
Dimensions
Length – Internal 246 mm 225 mm 460 mm 230 mm
– External 255 mm 235 mm 474 mm 250 mm
Width – Internal 171 mm 225 mm 380 mm 105 mm
– External 180 mm 235 mm 396 mm 125 mm
Depth – Internal 119 mm 100 mm 120 mm 110 mm
– External 125 mm 117 mm 128 mm 125 mm
Fixing centres (mm) 240 x 165 215 x 215 380 x 310 235 x 110
IP rating IP66 IP66 IP56 IP67
Temperature range -15 to +75 °C -15 to +75 °C -25 to +60 °C -40 to +80 °C
Flammability UL 94 V2 UL 94 V2 UL 94 V0 UL 746C 5V
5/143
—
Protection and safety
Protector accessories
OVR CME Series
5
able with 4, 8, 16 and 32 mounting holes.
Application
Earth Use OVR CME kits to simultaneously mount and earth groups of single and double earth stud
Earth
Earth
connection Earth connection
connection
protectors. Each single earth stud protector requires one OVR CME mounting position and
(not supplied) (not supplied)
connection
(not supplied)
(not supplied)
each double earth stud protector requires two OVR CME mounting positions, this includes:
• High conductivity copper with electro-tin plating and nylon insulating pillars, for low
impedance to earth
Single earth stud protectors which are:
– OVR 06D – OVR 06E – OVR 06H – OVR TN
Assembly of OVR CME kit – OVR 15D – OVR 15E – OVR 15H – OVR RTD
Earth connection (not supplied) – OVR 30D – OVR 30E – OVR 30H – OVR CCTV/B
– OVR 50D – OVR 50E – OVR 50H – OVR CCTV/T
– OVR 110D – OVR 110E – OVR 110H – OVR RS485
Double earth stud protectors which are:
– OVR 240-16A
Once you know how many OVR CME mounting positions you require choose a OVR CME kit to
suit:
– OVR CME 4 has 4 mounting positions
– OVR CME 8 has 8 mounting positions
– OVR CME 16 has 16 mounting positions
– OVR CME 32 has 32 mounting positions
Accessories Installation
Enclosures suitable for a OVR CME The earth bar is supported by a series of mounting pillars (which are fixed to the cubicle or box
4 and its associated protectors: base). Protectors are attached to the OVR CME’s earth bar via their earth stud(s) and earthed with
(OVR WBX 4/GS), OVR CME 8 and shared connections to earth. We suggest one earth connection per mounting pillar.
protectors (OVR WBX 8/GS) or one or
two OVR CME 16 and protectors
(OVR WBX 16/2/G)
120 mm 200 mm
25 mm
CME 4 CME 8
100 mm 180 mm
3 mm 380 mm
CME 16
90 mm
180 mm 180 mm
740 mm
End view CME 32
(all products) 180 mm 180 mm 180 mm 180 mm
—
Protection and safety
Protector accessories
Accessories
5
—
E 90. Uncompromising performance
A safe and smart range designed for quick,
flexible and error-proof installation
5
Compactness
Reliability
The compact dimensions enable to
Venting grooves and cooling
close the switchboard door even when
chambers improve heat dissipation
the fuse holder is open, thus ensuring
even in multiple-pole configurations.
total safety during maintenance.
Completeness
The fuse tripping can be easily
displayed, thanks to the special
blown fuse indicator light.
Universal use
Screw holes have increased diameter
to accomodate insulated screwdrivers
and electric screwdrivers.
5/146 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
E 90. Uncompromising performance
A safe and smart range designed for quick, flexible and error-proof installation
5
Fuseholder profile has been designed for maximum ease of The compact dimensions enable to close the switchboard
use: the 90° flip hinge with ergonomic knob, makes the door even when the fuseholder is open, thus ensuring total
replacement of fuses easier even in small spaces or when safety during maintenance.
wearing protective gloves.
With the Prozidriv PZ2 screws tightening can be performed Venting grooves and cooling chambers improve heat
by exerting less torque than conventional screws, and the dissipation even in multiple-pole configurations.
same electric screwdriver can be used for all terminals. The reduced operating temperature inside fuseholders
Moreover, the PS connection busbars facilitate the ensures durability and reliability of the devices over time.
connecting operations, making the wiring both simple and
safe and providing complete integration with S 200 and SN
201 System pro M compact® circuit-breakers.
5/147
—
Protection and safety
E 90 fuse switch disconnectors
Technical features
Type E 90/20 E 90/32
Rated current A 20 32
5
Type of current AC
Fuse [mm] 8 x 31 10 x 38
IEC 60947-3
Utilization category AC-22B AC-22B
Markings [V] 400 400
for lower temperature verify fuse technical characteristics, for higher temperature refer to derating
(1)
Shock withstand
• Shock testing according to IEC 60068-2-27 : 15 g/11 ms/18 shocks
• Shock testing according to IEC 61373: Category 1 Class B
Materials
Plastic parts Case: Material PA 6 +30 % glass fibre
Self extinguishing class: V2 (UL94)
Temperature resistance: 130 °C
Opening handle Material PA 66 +25 % glass fibre
Self-extinguishing class V0 (UL94)
Temperature resistance: 140 °C
Metal parts Clips Silver plated copper
Clip spring Stainless steel
Terminals Galvanized steel
The E 90 series is environmental friendly and protects the health of people: all used materi-
als are conform to the RoHS and REACH directives and they completely exclude hazardous
substances and halogen.
5/148 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
E 90 fuse switch disconnectors
thermoplastic material resistant to high temperatures (all materials are UL listed) while the
contact clips are in silver plated copper.
E 90 fuse switch disconnectors can be sealed or padlocked to ensure operator safety during
E 92
maintenance. Versions with blown fuse indicator allow to check whether the fuse is still
working correctly or not. For easy and quick installation E 90 range is totally compatible with
connecting bars, terminals and caps of S 200 MCBs.
Thanks to cURus approval, they can be installed in UL certified machines.
—
Protection and safety
E 90h fuseholders
Technical features
Type E 90hN/20 E 90hN/32
Rated currrent [A] 20 32
5
Type of current AC
Fuse [mm] 8 x 31 10 x 38
Max power dissipation accepted [W] 2.6 3.2
Rated frequency [Hz] 50-60
Tightening torque [Nm] PZ2 0.8-1.2
E 91hN Protection degree IP20
Terminals cross-section [mm2] 16
Cross-section rigid copper conductors [mm2] 1.5-16
Cross-section stranded copper conductors [mm2] 1.5-10
Operating temperature [°C] -5/+40 (1)
IEC 60269-3
Rated voltage [V] 400
E 93hN (1)
for lower temperature verify fuse technical characteristics, for higher temperature refer to derating
table in Chapter 5 of Electrical installation solutions for buildings - Technical details
(2)
for more than 24h max temperature is +55 °C
E 90h fuseholders
E 90h fuseholders are suitable for protection against overloads and short circuits. Available
in a single module 1P+N version and in a three-module 3P+N version, they are designed for
use with gG and aM cylindrical fuse links. The body is made from self-extinguishing material
resistant to high temperatures, while the contact clips are in silver-plated copper. E 90h
fuseholders can be sealed or padlocked to assure operator safety during maintenance.
Versions with blown fuse indicator allow to check whether the fuse is still working correctly
or not.
—
Protection and safety
E 90 PV fuse disconnectors
Technical features
Type E 90/32 PV E 90/32 PV according to UL
Rated current [A] 30
5
Type of current DC
Fuse [mm] 10 x 38
Max power dissipation accepted [W] 3
Rated frequency [Hz] -
Tightening torque PZ2 2-2.5 Nm PZ2 18-22 lb-in
E 90 PV
Protection degree IP20
Terminals cross-section [mm2] 25
Cross-section rigid copper conductors 1.5 - 25 mm2 n..a.
Cross-section stranded copper conductors 1.5 - 16 mm2 8÷3 AWG
Operating temperature [°C] -5/+40 (1)
Storage temperature [°C] -25/+70 (2)
Altitude [m] 2000
Voltage range for LED indicator light 24-1000 AC/DC
(only s version)
Can be padlocked (open) ■
IEC 60947-3
Utilization category DC-20B
Rated voltage [V] 1000
for lower temperature verify fuse technical characteristics, for higher temperature refer to derating
(1)
E 90 PV fuse disconnectors
E 90 PV series fuse disconnectors, designed for operating voltages of 1000 V DC with
utilization category DC-20B, are particularly suited for protection against overcurrents of
photovoltaic systems.The single-pole or two-pole E 90 PV disconnectors for 10.3 x 38 mm
cylindrical fuse links offer a reliable, compact and affordable solution for photovoltaic
installations. Versions with blown fuse indicator allow to check whether the fuse is still
working correctly or not.
—
Protection and safety
E 90 PV 1500 fuse holder
Technical features
Type E90/32 PV1500
Reference standards - IEC 60269-1,-2,-6 UL 4248-19
5
Rated current [A] 32 (acc. IEC) / 30 (acc. UL)
Rated operational voltage [V] 1500 V DC
Fuse size [mm] 10×85 and 10/14×85
Max. power dissipation accepted [W] 6
Tightening torque [Nm] PZ2 2-2.5 Nm (PZ2 18-22 lb-in)
Protection degree - IP20
Cross section rigid copper conductors (1 wire) [mm2] 16-10 AWG
Cross section stranded copper conductors (1 wire) [mm2] 0.75 – 25 (18-4 AWG)
E 90 PV 1500
Cable temperature [°C] max 90 (acc. UL)
Operating temperature [°C] > -5
Storage temperature [°C] > -25
Approvals - UL , CCC
E 90 PV fuse holder
The E 90 PV 1500 series of fuse holders has been designed for applications up 1500 V DC.
Thanks to their rated voltage up to 1500 V DC they are the ideal solution for protecting cells
and inverters. In case of maintenance, they ensure isolation of circuits and strings up to
1500 V in direct current, in total safety. The main features of E 90 PV 1500 fuse holders in-
clude venting grooves and cooling chambers which improved heat dissipation.
—
Protection and safety
E 90 50/125 fuse disconnectors
Technical features
Type E 90/50 E 90/125
Rated current [A] 50 100*
5
Type of current AC
Fuse [mm] 14 x 51 22 x 58
Max power dissipation accepted [W] 5 9.5
Rated frequency [Hz] 50-60
Tightening torque [Nm] PZ2 3-3.5 PZ2 3.5-4
Protection degree IP20**
Terminals cross-section [mm2] 35 50
E 90 50/125
Cross-section rigid copper conductors [mm2] 2.5 - 35 4 - 50
Cross-section stranded copper conductors [mm2] 2.5 - 25 4 - 35
Can be sealed closed ■
IEC 60947-3
Utilization category AC-20B
Rated voltage [V] 690
* 125A with fuses of type aM and in combination with a device which guarantees protection against overload
** The protection degree IP20 is obtained also as standalone unit with respect to wire size of 10mm 2
—
Protection and safety
E 90 CC fuseholders
Technical features
Type E 90/30 CC
Rated voltage [V] 600
5
Rated current [A] 30
Type of current AC/DC
Rated frequency [Hz] 60
Fuse class CC
E 91 Tightening torque [Nm] PZ2 2-2.5*
[lb-in] PZ2 18-22**
Terminals cross-section [mm2] 25
Cross-section rigid 1 wire 1.5-25 mm2 (16-10 AWG)
copper conductors 2 wires 5 mm2 (10 AWG)
Cross-section stranded 1 wire 1.5-16 mm2 (16-3 AWG)
copper conductors 2 wires 2-5 mm2 (14-10 AWG)
Voltage range for LED indicator light (only s version) [V] 24 - 1000 AC/DC
Can be sealed closed ■
The E 90 fuse carriers for Class CC cylindrical fuse links are specifically designed for the
North American market in compliance with the UL standards. In accordance with the
reference standards UL 4248-1 and UL 4248-4, they come in voltage and current ratings up
to 600V and 30A. They are available in 1P, 1P+N, 2P, 3P, 3P+N and 4P versions. They can be
padlocked open and sealed closed.
The E 90 fuse carriers are the ideal solution for process control and industrial systems,
automation systems, industrial installations and control circuits. The versions with blown
fuse indicator light provide a visual signal of the fuse break condition
—
Protection and safety
E 90 J fuse fuseholders
Technical features
Type E 90/30 J E 90/60 J
Rated current [A] 30 60
5
E 90 Class J
The E 90 Class J fuse carriers are the ideal solution for industrial systems, industrial installa-
tions and control circuits. They are specifically designed for the North American market in
compliance with the UL standards. In accordance with the reference standard UL 4248-8,
they come in voltage and current ratings up to 600V and 30/60A. They are available in 1P,
2P and 3P versions. The versions with blown fuse indicator light provide a visual signal of the
fuse break condition. They can be padlocked open and sealed closed to ensure operator
safety during maintenance operations.
—
Protection and safety
Cylindrical fuses E 9F gG
Technical features
Rated voltage [V] 400, 500, 690 AC
Rated current [A] 0.5…125
5
Breaking capacity [kA] 20, 80, 120
Overall dimensions [mm] 8.5x31.5 , 10.3x38 , 14x51 , 22x58
Weight [g] 4, 7, 18, 48
E 9F8
Reference standards IEC 60269-2; ROHS 2002/98/CE
Marks LLOYD, BV
—
Protection and safety
Cylindrical fuses E 9F gG
—
Protection and safety
Cylindrical fuses E 9F gG
E 9F gG cylindrical fuses
The E 9F gG cylindrical fuses, coupled with E 90 and E 90 50/125 fuse disconnectors, are the
ideal solution for protection against overload and short-circuit. They feature a fast tripping
5
curve that is ideal for protecting electronic devices, transformers and electric cables. The E
9F gG series is available for all the main sizes (8.5 x 31.5 mm, 10.3 x 38 mm, 14 x 51 mm e 22 x
58 mm) and with a wide range of rated current values (from 1 A to 125 A and up to 690 V AC).
All the E 9F series fuses conform to the RoHS directive and are type-approved in accordance
with the most important international naval marks.
—
Protection and safety
Cylindrical fuses E 9F gG
piece
In mm EAN Type code Order code kg pc.
2 14x51 775232 E 9F14 GG2 2CSM277523R1801 0.018 10
4 14x51 773030 E 9F14 GG4 2CSM277303R1801 0.018 10
6 14x51 770831 E 9F14 GG6 2CSM277083R1801 0.018 10
8 14x51 910039 E 9F14 GG8 2CSM291003R1801 0.018 10
10 14x51 909835 E 9F14 GG10 2CSM290983R1801 0.018 10
12 14x51 909637 E 9F14 GG12 2CSM290963R1801 0.018 10
16 14x51 587835 E 9F14 GG16 2CSM258783R1801 0.018 10
20 14x51 576037 E 9F14 GG20 2CSM257603R1801 0.018 10
25 14x51 564232 E 9F14 GG25 2CSM256423R1801 0.018 10
32 14x51 586937 E 9F14 GG32 2CSM258693R1801 0.018 10
40 14x51 575139 E 9F14 GG40 2CSM257513R1801 0.018 10
50 14x51 563334 E 9F14 GG50 2CSM256333R1801 0.018 10
—
Protection and safety
Cylindrical fuses E 9F aM
Technical features
Rated voltage [V] 400, 500, 690 AC
Rated current [A] 0.5…125
5
Breaking capacity [kA] 20, 80, 120
Overall dimensions [mm] 8.5x31.5, 10.3x38, 14x51, 22x58
E 9F10 aM
E 9F10 aM cylindrical fuses 10.3 x 38 mm
Type Rated current Rated voltage Breaking capacity
[A] [V AC] [kA]
E 9F10 AM05 0.5 500 120
E 9F10 AM1 1 500 120
E 9F10 AM2 2 500 120
E 9F10 AM4 4 500 120
E 9F10 AM6 6 500 120
E 9F10 AM8 8 500 120
E 9F10 AM10 10 500 120
E 9F10 AM12 12 500 120
E 9F10 AM16 16 500 120
E 9F10 AM20 20 500 120
E 9F10 AM25 25 400 120
E 9F10 AM32 32 400 120
5/160 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Cylindrical fuses E 9F aM
—
Protection and safety
Cylindrical fuses E 9F aM
E 9F aM cylindrical fuses
The E 9F aM cylindrical fuses, coupled with E 90 and E 90 50/125 fuse disconnectors, are the
ideal solution for protection against overload and short-circuit. They feature a delayed
5
tripping curve and are therefore ideal for protecting industrial motors that require high
inrush current during the starting phase. The E 9F aM series is available for all the main sizes
(8.5 x 31.5 mm, 10.3 x 38 mm, 14 x 51 mm e 22 x 58 mm) and with a wide range of rated current
values (from 1 A to 125 A and up to 690 V AC). All the E 9F series fuses conform to the RoHS
directive and are type-approved in accordance with the most important international naval
marks.
—
Protection and safety
Cylindrical fuses E 9F aM
piece
In mm EAN Type code Order code kg pc.
1 14x51 575337 E 9F14 AM1 2CSM257533R1801 0.018 10
2 14x51 563532 E 9F14 AM2 2CSM256353R1801 0.018 10
4 14x51 586234 E 9F14 AM4 2CSM258623R1801 0.018 10
6 14x51 574439 E 9F14 AM6 2CSM257443R1801 0.018 10
8 14x51 562634 E 9F14 AM8 2CSM256263R1801 0.018 10
10 14x51 775331 E 9F14 AM10 2CSM277533R1801 0.018 10
12 14x51 773139 E 9F14 AM12 2CSM277313R1801 0.018 10
16 14x51 770930 E 9F14 AM16 2CSM277093R1801 0.018 10
20 14x51 587033 E 9F14 AM20 2CSM258703R1801 0.018 10
25 14x51 575238 E 9F14 AM25 2CSM257523R1801 0.018 10
32 14x51 563433 E 9F14 AM32 2CSM256343R1801 0.018 10
40 14x51 586135 E 9F14 AM40 2CSM258613R1801 0.018 10
45 14x51 574330 E 9F14 AM45 2CSM257433R1801 0.018 10
50 14x51 562535 E 9F14 AM50 2CSM256253R1801 0.018 10
—
Protection and safety
Cylindrical fuses E 9F gPV
5
Rated operational voltage [V] 1000 DC 1500 DC
Breaking capacity [kA] 10 50
Overall dimensions [mm] 10.3 x 38 10 x 85
—
Protection and safety
ILTS-E D0 Fuse-switch-disconnectors
Technical data
Reference standards DIN VDE 0638, EN 60947-3, EN 660269-3-1
Approval VDE
5
Fuse-switch-disconnector
Poles Bbn Order details Price Weight Pack
4016779 1 piece 1 piece unit
—
Protection and safety
ISS D0 Fuse carriers
Technical features
Size D01 D02
Current type AC (50 Hz)/DC AC (50 Hz)/DC
5
Rated voltage 400 V AC/250 V DC 400 V AC/250 V DC
Rated current 16 A 63 A
Rated short-circuit current 50 kA (AC) 50 kA (AC)
8 kA (DC) 8 kA (DC)
ISS 16/1
For fuse links with losses per phase up to 2.5 W 5.5 W
D0 fuse carrier
Poles Screw cover/fuse Bbn Order details Price Weight Pack
4016779 1 1 piece unit
piece
EAN Type code Order code kg pc.
1 E14 D01 65579 8 ISS 16/1 2CDE111001R1902 0.08 9
ISS 16/3
1 E18 D02 65581 1 ISS 63/1 2CDE161001R1902 0.08 9
3 E14 D01 65580 4 ISS 16/3 2CDE113001R1902 0.24 9
3 E18 D02 65582 8 ISS 63/3 2CDE163001R1902 0.24 9
ISS 63/3
5/166 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
Busbars and accessories for ILTS-E and ISS
Busbars for fuse-switch-disconnector ILTS-E and fuse carrier ISS: 1pole or 3pole
End caps:
PS 1/39/16 ILTS-E: END 1.1
5
Busbars
Cross- Length No. of Cu Bbn Order details Price Weight Pack
section poles factor 4012233 1 piece 1 piece unit
—
Protection and safety
Busbars and accessories for ILTS-E and ISS
D0 screw caps acc. to DIN VDE 0636-3, IEC/EN 60269-3, 400 V AC
Plastic version, RAL 7037
Connector sleeves Rated Colour Power Bbn Order details Price Weight Pack
5
D 01 D 02
current code loss 4012233 1 piece 1 piece unit
2-10 A 2-50 A
—
Protection and safety
Electronic Protection Devices for use behind 24 V DC Switch Mode Power Supplies
Operating data
Operating voltage UB 24 V DC (18...32 V)
Current rating IN fixed current ratings: 0.5, 1, 2, 3, 4, 6, 8, 10, 12 A
5
Load circuit
Load output Power-MOSFET switching output (high slide switch)
Overload disconnection typically 1.1 x IN (1.05...1.35 x IN)
Short-circuit current IK active current limitation (see table 1)
Trip time see time/current characteristics
For electronic disconnection typically 3 s at ILoad > 1.1 x IN
typically 100 ms...3 s at ILoad > 1.8 x IN (or 1.5 x IN/1.3 x IN, )
Temperature disconnection internal temperature monitoring with electronic disconnection
Low voltage monitoring load output with hysteresis, no reset required: load »OFF« at UB< 8 V
Starting delay tStart typically 0.5 sec after every switch-on and after applying US
Disconnection of load circuit electronic disconnection
Free-wheeling circuit suitable external free-wheeling circuit to be used
with inductive load
Several load outputs must not be connected
in parallel
Signal output F
Electrical data potential-free auxiliary contact max. 30 V DC/0.5 A,
min. 10 V DC/10 mA
ON condition LED green voltage UB applied, switch S1 is in ON position no overload,
no short circuit
OFF condition LED off device switched off (switch S1 is in OFF position)
no voltage UB applied
Fault condition LED orange overload condition > 1.1 x IN up to electronic disconnection
Aux. contact single signal, make contact
contact open, terminal 13-14
Fault signal output fault conditions
- no operating voltage UB
- ON/OFF switch S1 is in OFF position
- red LED lighted (electronic discon nection)
5/169
—
Protection and safety
Electronic Protection Devices for use behind 24 V DC Switch Mode Power Supplies
General data
Fail-Safe element backup fuse for EPD24 not required
because of the integral redundant fail-safe element
5
Housing material moulded
Mounting symmetrical rail to EN 50022-35x7.5
Ambient temperature 0...+50 °C (without condensation, see EN 60204-1)
Storage temperature -20...+70 °C
Humidity 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate
class 3K3 to EN 60721
Vibration 3 g, test to IEC 60068-2-6 test Fc
Protection degree housing: IP20 DIN 40050
terminals: IP20 DIN 40050
EMC (EMC directive, CE logo) emission: EN 61000-6-3
susceptibility: EN 61000-6-2
Isolations coordination (IEC 60934) 0.5 kV/pollution degree 2 reinforced insulation in operating
area
Dielectric strength max. 32 V DC (load circuit)
Isolation resistance (OFF condition) n/a, only electronic disconnection
Approvals/Declarations of conformity UL 2367 Solid State Overcurrent Protectors
UL 1604, (class I, division 2, groups A, B, C, D)
UL 508
CSA C22.2 No. 213 (class I, division 2)
CSA C22.2 No. 142
CSA C22.2 No. 14
CE logo
Dimensions (B x H x T) 12.5 x 80 x 83 mm
Weight approx. 65 g
Terminals Line+/LOAD+/0V
Screw terminals M4
Max. cable cross section flexible with wire 0.5 – 10 mm2
end ferrule w/wo plastic sleeve
Multi-lead connection (2 identical cables) 0.5 – 4 mm2
rigid/flexible
Flexible with wire end ferrule without plastic 0.5 – 2.5 mm2
sleeve
Flexible with TWIN wire end ferrule with 0.5 – 6 mm2
plastic sleeve
Wire stripping length 10 mm
Tightening torque (EN 60934) 1.5 – 1.8 Nm
—
Protection and safety
Electronic Protection Devices for use behind 24 V DC Switch Mode Power Supplies
The protection devices EPD24 extend the ABB product range of modular DIN rail compo-
nents by electronic overcurrent protection modules for selective protection of 24V DC load
circuits.
5
Features
• Selective load protection, one electronic trip characteristics.
• Active current limitation for safe connection of capacitive loads up to 20.000 µF and on
overload/short circuit.
• Current ratings 0.5 A...12 A.
• Reliable overload disconnection with 1.1 x IN
• Manual ON/OFF button
• Clear status and failure indication through LED and auxiliary contact.
• Integral fail-safe element adjusted to current rating.
• Width per unit only 12.5 mm.
• Rail mounting
• Ease of wiring through busbar LINE+ and 0 V as well as signal bars.
• UL- and CSA-approvals allow international use of the devices.
Accessories
Bbn Order details Price Weight Pack
4016779 1 1 piece unit
piece
EAN Type code Order code kg pc.
Busbars for LINE+ and 0 V, 830140 EPD-BB500 2CDE605100R0500 0.20 10
grey insulation,
length 500 mm 1)
Signal Bars for aux. 830164 EPD-SB21 2CDE605200R0021 0.04 10
contacts,
grey insulation,
length 21 mm
1) Max. load with one line entry Imax = 50 A (recommended: center-feeding)
Max. load with two line entries Imax = 63 A
5/171
—
Protection and safety
SQZ3 phase and sequence relay
Technical features
Supply voltage [Vn] 400 V AC
Frequency [Hz] 50/60
5
Contact type [A] 1 CO, 250 V, 10 A (cosϕ=1) safety switching
Minimum voltage adjustment trimmer [%] 100 to 70 % of Vn
Intervention delay adjustment trimmer [s] 2 to 20 (only for min. voltage)
Protection degree [IP] 20
SQZ3
Operating temperature [°C] -10…+55
Power consumption [W] 1.5
Modules [n°] 3
If one of the three failures is detected, the output relay (safety switching contact) intervenes
with a delay adjustable from 2 to 20 seconds for minimum voltage only and controls the
following:
• acoustic alarms
• motor controlling contactors
• circuit-breakers with coils.
—
Protection and safety
E 236 undervoltage monitoring relays
Technical features
US 1 US 2
Rated voltage 250 V AC
5
—
Protection and safety
E 236 undervoltage monitoring relays
Technical features
5
US 1.1 US 2.1 US 1.1D
Supply circuit
Supply voltage (= measured voltage) 3N~ 400/230 V AC (terminals N-C1-C2-C3)
Overvoltage permanent 3N~ 459/265 V AC
Rated frequency 48 – 63 Hz (AC sinus)
Rated surge voltage: 4 kV
Overvoltage category III
All measured inputs have to be connected to one phase each. If no three-phase measure-
ment should be carried out, measured inputs have to be connected to one phase to apply the
required voltage to all measured inputs. If a load causes inverse voltage exceeding the
threshold value Us, phase failures cannot be identified.
A neutral conductor must be connected in any case!
5/174 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
E 236 undervoltage monitoring relays
Devices for panel installation onto mounting rails (35 mm) according to DIN EN 60715
mounting depth: 68 mm
mounting width: 17.5 mm = 1 module
5
E 236-US 1.1D
5/175
—
Protection and safety
ISL industrial insulation monitoring devices
5
Power consumption [VA] 3 4 6
ALARM threshold [kW] 30 - 300 (5 levels, selectable)
TRIP threshold [kW] 10 - 60 10 - 100 30 - 300 (adjustable by
(5 levels by switches) (5 levels selectable) potentiometer)
ISL LED ON ■ ■ ■
indications TRIP ■ ■ ■
ALARM ■
+/- ■ ■ ■
Reset ■
—
Protection and safety
ISL industrial insulation monitoring devices
Auxiliary power supply [V] 220-240 V AC 220-240 V AC 100÷130 V AC/ 220- 240 V AC
220÷240 V AC
Power consumption [VA] 3 3 5 3
TRIP threshold [kW] 100 10 -150 10-100 0.1-10 MW
(5 levels) (5 levels) (8 levels)
ISL-A
LED ON ■ ■ ■ ■
indications TRIP ■ ■ ■ ■
ALARM ■
—
Protection and safety
ISL industrial insulation monitoring devices
5
of exposed conductive parts. Therefore, in case of earth leakage in an IT network it is not
necessary to interrupt the supply, but it is still essential to continually monitor the insulation
level in order to detect faults and restore optimal functioning of the system.
In industrial installations, IT networks are used when operational continuity is an intrinsic re-
ISL-A quirement of the production process, due to both technical and economic considerations.
Such applications include: metalworking and chemical industries, explosion risk locations,
railway lines and vehicles, uninterruptible power supplies, cinema sets, emergency lines, fire
water pumps and emergency lighting.
—
H+ Line. Operational continuity
A wide range which ensure safety and reliability
in hospital segment
5
Lifting eyebolts
OVR surge
protection device
ISOLTESTER-DIG-RZ
insulation monitoring
device
M1175-FL schuko
soket outlet
5
Specifically designed and assembled for medical use Artu K series floor standing switchboards are equipped with
according to the IEC EN 61558-2-15, it ensures protection a cable container that makes installation and wiring easier,
against indirect contacts without the need to interrupt the both for the electrical systems distributed along the false
circuit automatically upon the first grounding fault. cieling, as under the floor.
Thanks to its two PT100 temperature probes, on primary It is possible to reach any terminal block in a comfortable
and secondary winding, it is possible to monitor the way.
transformer over temperature produced by any eventual Finally, there is a copper equipotential bonding busbar
overload, and therefore anticipating any breakdown. which may lodge up to 20 additional connections, providing
The transformer is mounted on the base of the switchboard grounding connections to all the external masses which are
in order to ease handling and installation operations. present in the medical premises, and avoiding the creation
of further cascade sub-nodes that are not allowed.
This is an insulation monitoring device for group 2 medical Floor standing QSO switchboards are composed of modular
locations fully compliant with the IEC 60364-7-710 reference ArTu K series enclosures. The switchboards are equipped
standard. It integrates all the performances established by with venting grooves that guarantee proper natural
the reference standard, such as overload and overcurrent convection, useful to dissipate the heat produced by the
monitoring, together with traditional IT system earthing transformer during its normal functioning.
insulation measurement.
5/180 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
H+Line products
years, ABB has developed an increasingly more complete product with higher performance
to meet the needs of more demanding customers and guarantee patient and operator
safety.
H+Line products are specifically designed for group 2 medical environments in full
compliance with Standard IEC 60364-7-710, specifically:
• Intensive therapy wards, operating theatres, cardio surgical rooms, ICU…
• Day hospitals, clinics, rest homes, dental and veterinary clinics, etc.
H like
Hospital
+ like health
and first aid
—
Protection and safety
H+Line products
5
ISOLTESTER Insulation monitoring device for IT-M 230 V circuits
—
Protection and safety
ISOLTESTER-DIG insulation monitoring devices
Technical features
ISOLTESTER-DIG-RZ ISOLTESTER-DIG-PLUS/RS
Aux supply 115 - 230 V 50-60Hz
5
—
Protection and safety
ISOLTESTER-DIG insulation monitoring devices
5
medical equipment.
ISOLTESTER-DIG
ISOLTESTER-DIG ISOLTESTER range of insulation monitoring device allows IT-M network monitoring, assuring
safety for patients and medical personnel avoiding supply interruption in case of first
earthing fault according to IEC 60364-7-710 Standard.
The ISOLTESTER-DIG range assures safety to patients and medical personnel, signalling
when a fault to earth occurs. Thanks to its innovative technology it is used to sense the
insulation level of the network by far more efficiently compared to traditional insulation
H+Line monitoring devices.
—
Protection and safety
SELVTESTER insulation monitoring devices for insulated networks at 24 V AC/DC
Technical features
Network voltage and auxiliary 24 V 50-60 Hz/DC ± 20 %
power supply
5
—
Protection and safety
QSD remote signalling panel
Technical features
Signals Green LED network ON
Red LED overload ALARM
5
Yellow LED insulation ALARM
intermittence 2 Hz dB ALARM, acoustic signaller, emission 2400 Hz
Buttons TEST and MUTE buttons
QSD Terminal cross-section 2.5 mm2
Protection degree IP30
Installation type universal flush mounted box
Weight 200 g
Operating temperature -10 ÷ 60 °C
Storage temperature -25 ÷ +80 °C
Relative humidity ≤ 95 %
H+Line Insulation
Cables cross-section
2500 Vrms 50 Hz 60 s
0.35 mm2 for 300 m
Compatibility ISOLTESTER-DIG-RZ, ISOLTESTER-DIG-RS, ISOLTESTER-DIG, PLUS,
SELVTESTER-24
Reference standards safety EN 61010-1 product EN 61557-8/IEC 60364-7-710/
UNE 20615 electromagnetic compatibility EN 61326-1
—
Protection and safety
TI switchboards and devices for medical locations
Technical characteristics
TI 3 TI 5 TI 7.5 TI 10
TI 3-S TI 5-S TI7.5-S TI 10-S
5
H+Line
Short circuit voltage drop <3%
Inrush current [A] < 221 < 369 < 553 < 738
Power loss [W] 120 150 260 320
Winding separation double insulation
Metallic shield ■
Accessories
Bbn Order details Price Weight Pack
8012542 1 1 piece unit
piece
EAN Type code Order code kg pc.
Shock absorber 2557920 AMM 2CSM900000R1541 1 4
5/187
—
Protection and safety
QSO selection table
Series Type Power Installation IT-M section TN-S PT100 OVR Unifix L I/O KNX SELV
[kVA] type feeder lines section 24 V
feeder line
5
lines
S
wall 2x10A+5x16A
QSO 3S Classic 3 - ■
mounted +1x25A
wall 2x10A+5x16A
QSO 5S Classic 5 - ■
mounted +1x25A
M
floor
QSO 3M Classic 3 3x10A+7x16A 1x10A ■
standing
floor
QSO 5M Classic 5 3x10A+7x16A 1x10A ■
standing
floor
QSO 7.5M Classic 7.5 3x10A+7x16A 1x10A ■
standing
L
floor 1x10A+2x
QSO 10L Classic 10 6x10A+9x16A ■
standing 16A
—
Protection and safety
QSO switchboards and components for medical locations
Technical features
QSO wall type QSO floor type
Rated operational voltage (Ue ) 230 V ~ ± 15%
5
Rated frequency 50 - 60 Hz
Number of phases 1 + N ~⁄ PE
QSO
Rated voltage of auxiliary service circuits 24 - 230 V ~
Rated insulation voltage (Ul) 300 V - *2500 V
Earthing system TT/TN-S
Maximum prospective short circuit 10 kA RMS Sym ***
current to the input terminals (Icc)
Max. altitude 2000 m a.s.l.
Pollution degree 1 **
Degree of protection against impacts K 09 (5 kg - 200 mm)
(IK code) EN 50102 I
Degree of relative humidity at 50 % with max. temp. +40 °C
temperature °C
Operating temperature -5 °C - +55 °C
Storage temperature -25 °C - +40 °C
Protection degree EN 60529 QSO 3S Classic IP 40 QSO 3M Classic IP 54
QSO 5S Classic IP 40 QSO 5M Classic IP 54
QSO 3S Premium IP 40 QSO 5M Premium IP 54
QSO 5S Premium IP 40 QSO 7.5M Premium IP 54
QSO 10L Classic IP 54
QSO 7.5L Premium IP 54
QSO 10L Premium IP 54
* Dielectric strength test voltage.
** Corresponds to no pollution or only dry and non-conductive pollution.
*** Value conditioned by upstream coordination with NH 00 100A gL-gG fuses
5/189
—
Protection and safety
QSO switchboards and components for medical locations
5
Three series are available: S, M and L. Each one can be customized with two layouts. The
CLASSIC version contains the instrumentation essential for protection against direct con-
QSO S tacts, while the PREMIUM version also has, depending on the type of switchboard, additional
devices intended for:
• emergency power cut-off of operating theatre circuits outside of the patient area
(lighting, radiology sockets, etc.)
• 24 V SELV line for supplying scialytic lamps
• overvoltage protection
• Unifix L fast-wiring system
• I/O module for managing xon alarms through KNX protocol
ABB provides, for its switchboards for operating theatres, the declaration of conformity
QSO M required to commission the system, ensuring the installer that the system is built in
compliance with technical standards. To ensure the best efficiency of the QSO will be
delivered in a new wooden packing.
Power Instal- TN-S IT-M Bbn Order details Price Weight Pack
lation section section 801254 1 1 piece unit
type feeder feeder piece
kVA lines lines EAN Type code Order code kg pc.
3 wall 2x10A 2611226 QSO 3S Classic 2CSM261122R1551 73 1
mounted +5x16A
+1x25A
QSO L
5 wall 2x10A 2736929 QSO 5S Classic 2CSM273692R1551 87.5 1
mounted +5x16A
+1x25A
3 wall 1x10A 2x10A 2736028 QSO 3S 2CSM273602R1551 75 1
mounted +2x16A +5x16A Premium
+1x25A
5 wall 1x10A 2x10A 2736820 QSO 5S 2CSM273682R1551 90 1
mounted +2x16A +5x16A Premium
+1x25A
Power Instal- TN-S IT-M Bbn Order details Price Weight Pack
lation section section 801254 1 1 piece unit
type feeder feeder piece
kVA lines lines EAN Type code Order code kg pc.
3 floor 1x10A 3x10A 2735922 QSO 3M 2CSM273592R1551 126 1
H+Line 5
standing
floor 1x10A
+7x16A
3x10A 2736721
Classic
QSO 5M 2CSM273672R1551 141 1
standing +7x16A Classic
7.5 floor 1x10A 3x10A 2735823 QSO 7.5M 2CSM273582R1551 147.5 1
standing +7x16A Classic
3 floor 1X10A 6x10A 2736622 QSO 3M 2CSM273662R1551 127 1
standing +2x16A +8x16A Premium
+1x25A
5 floor 1X10A 6x10A 2735724 QSO 5M 2CSM273572R1551 142 1
standing +2x16A +8x16A Premium
+1x25A
7.5 floor 1X10A 6x10A 2736523 QSO 7.5M 2CSM273652R1551 147.5 1
standing +2x16A +8x16A Premium
+1x25A
5/190 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Protection and safety
QSO switchboards and components for medical locations
Power Instal- TN-S IT-M Bbn Order details Price Weight Pack
5
—
Electrical installation solutions for buildings
Command and signaling
Index
6
SD 200 switch disconnectors 6/6
SHD 200 switch disconnectors 6/10
E 200 switches 6/14
E 463/3, E 480/3 switches 6/16
S800PV photovoltaic switch disconnectors 6/17
E 210 switches, pushbuttons
and indicator lights 6/20
ESB..N and EN..N installation contactors 6/30
E290 Latching relays 6/45
E297 Installation relay 6/48
FLR latching relays 6/57
E 260 latching relays 6/58
STD50 dimmers 6/60
STD universal dimmer 6/61
Transformers selection table 6/64
Control, isolating and safety transformers
selection table 6/66
TM-C, TM-S, TM-I control,
isolating and safety transformers 6/67
TS-C safety isolating transformers
for general use 6/70
TM bell transformers 6/71
TS bell transformers 6/72
SM, RM, TSM, TSR bells and buzzers 6/73
CP-D primary switch mode power supplies 6/75
Modular sockets selection table 6/77
Modular sockets 6/80
MA1-8001 DIN rail adapter 6/84
6/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
The details make the difference
Switch disconnector SD 200
6
6
Contact position indication Wide range of accessories PATENTED – Housing Design
The switch disconnector SD 200 is SD 200 is fully compatible to the com- By using state-of-the-art housing ma-
suited with a real contact position indi- plete range of System pro M compact terial, ABB is taking care of the envi-
cation (real CPI). You can easily iden- accessories like ronment. With the latest generation of
tify, if the SD 200 is in the ON or the • Auxiliary contacts, to be mounted on halogen free thermoplastics for
OFF position – easy and safe mainte- the left side, the right side or bottom SD 200 it’s possible to recycle the
nance work is possible. fitting switch disconectors completely with-
The position of the toggle and the red/ • Shunt trips out environmental pollution. The mate-
green display leaves no doubt about • Undervoltage release rial works for the stability.
the present switching position, while • Motor operating devices
the latter offers additional security, as
the exact position of the inner con-
tacts is always displayed.Thus, the de-
vice always supplies reliable informa-
tion in the event of an error.
—
Command and signaling
Switch disconnectors selection table
The SD 200 and SHD 200 extend the proven System pro M compact® series by ranges of switch
6
disconnectors which provides state-of-the-art safety and comfort. Both are available with 1 to 4 poles
with rated currents from 16 to 63 A and provides disconnection properties according to IEC/EN 60947-3.
The SD 200 offers performance on a different level. With a rated voltage of 253/440 V AC, a rated
conditional short-circuit current of 25 kA, terminals with protection from misconnection and a “Real
CPI” contact position indication the range is unique in its field of application. In addition SD 200 is fully
compatible with all MCB accessories.
The SHD 200 has a rated voltage of 240/415 V AC. A rated conditional short-circuit current of 10 kA
enables a wide range of applications.
The laser printing and the design of the devices allow a consistent optical appearance in the
distribution board.
The laser printing and the design of the devices allow a consistent optical appearance in the
distribution board. A VDE/CCC/EAC and KEMA approval ensures a wide scope of applications.
For technical differences between the ranges please refer to the selection table on the left page.
6/5
—
Command and signaling
SD 200 and SHD 200 switch disconnector ranges
6
Standards and approvals IEC/EN 60947-3 IEC/EN 60947-3 IEC/EN 60947-3
VDE/CCC/EAC/KEMA VDE/CCC/EAC/KEMA VDE/CCC/KEMA
Rated currents 16...63 [A] 16/25/32/40/50/63 16/25/32/40/50/63 –
80...125 – – 80/100/125
Rated voltage [V AC] 253/440 240/415 240/415
Short circuit withstand capacity [kA] 25 10 80...100 A : 25; 125 A : 6
Utilization category AC-23A AC-22A AC-22A
Electrical lifetime [Ops.] Ie < 32 A: 20,000 (AC) Ie < 32 A: 20,000 (AC) Ie < 100 A: 1,500 (AC)
Ie ≥ 32 A: 10,000 (AC) Ie ≥ 32 A: 10,000 (AC) Ie ≥ 125 A: 1,000 (AC)
Terminal cross section [mm2] 35 25 50
Terminal Cylinder lift terminal Cage terminal Cage terminal
Two terminal openings for
Yes No No
conductor and busbar
Safety wire guard Yes No No
Contact position indication Marking on toggle (I ON/0 OFF) Marking on toggle (I ON/0 OFF) Marking on toggle (I ON/0 OFF)
Real CPI (red ON/green OFF)
Combination with auxiliary elements
Auxiliary contacts Right side No Right side
Left side
Bottom side
Shunt trip Yes No No
Undervoltage release Yes No No
Motor operated remote control Yes No No
Padlock Yes Yes Yes
Removal without disassembling of the Yes No Yes
busbar
6/6 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
SD 200 switch disconnector
Technical data
Electrical data
Standards IEC/EN 60947-3
Poles 1P, 2P, 3P, 4P
Rated current Ie 16 A, 25 A, 32 A, 40 A, 50 A, 63 A
Utilization category AC-23A, DC-21A
6
—
Command and signaling
SD 200 switch disconnector
6
Signal/auxiliary contact Yes
Shunt trip Yes
Undervoltage release Yes
Motor operating device Yes
Padlock Yes
Approvals
CE and RoHS-conform
Approvals: VDE/CCC/EAC/KEMA
6/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
SD 200 switch disconnector
SD 200
Switch disconnector acc. to IEC/EN 60947-3 for panel installation onto DIN rail (35 mm)
Mounting depth: 68 mm
Mounting width: per pole = 17.5 mm = 1 module
Colour: grey, RAL 7035
Colour of switch lever: red RAL 3000
6
Ordering details
Rated current: 16 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
Rated current: 25 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
Rated current: 32 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
—
Command and signaling
SD 200 switch disconnector
Ordering details
Rated current: 40 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
6
1 253 904094 SD201/40 2CDD281101R0040 0.085 10
2 440 904155 SD202/40 2CDD282101R0040 0.170 5
SD 201 3 440 904216 SD203/40 2CDD283101R0040 0.255 1
4 440 904278 SD204/40 2CDD284101R0040 0.340 1
Rated current: 50 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
Rated current: 63 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
SD 203
SD 204
6/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
SHD 200 switch disconnector
Technical data
Electrical data
Standards IEC/EN 60947-3
Poles 1P, 2P, 3P, 4P
Rated current Ie 16 A, 25 A, 32 A, 40 A, 50 A, 63 A
Utilization category AC-22A, DC-21A
SHD 201
6
—
Command and signaling
SHD 200 switch disconnector
6
Signal/auxiliary contact No
Shunt trip No
Undervoltage release No
Motor operating device No
Padlock Yes
Approvals
CE and RoHS conform
Approvals: VDE/CCC/EAC/KEMA
6/12 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
SHD 200 switch disconnector
SHD 200
Switch disconnector acc. to IEC/EN 60947-3 for panel installation onto DIN rail (35 mm)
Mounting depth: 69 mm
Mounting width: per pole = 17.5 mm = 1 module
Colour: grey, RAL 7035
Colour of switch lever: red RAL 3000
6
SHD 202
Ordering details
Rated current: 16 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
Rated current: 32 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
SHD 204
V AC EAN Type code Order code piece kg pc.
1 240 904322 SHD201/32 2CDD271111R0032 0.075 10
2 415 904384 SHD202/32 2CDD272111R0032 0.150 5
3 415 904445 SHD203/32 2CDD273111R0032 0.225 1
4 415 904506 SHD204/32 2CDD274111R0032 0.300 1
6/13
—
Command and signaling
SHD 200 switch disconnector
Ordering details
Rated current: 40 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
6
2 415 904391 SHD202/40 2CDD272111R0040 0.150 5
SHD 201 3 415 904452 SHD203/40 2CDD273111R0040 0.225 1
4 415 904513 SHD204/40 2CDD274111R0040 0.300 1
Rated current: 50 A
Poles Rated Bbn Order details Price Weight Pack
voltage 4016779 1 1 piece unit
SHD 203
SHD 204
6/14 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
E 200 switches
—
Command and signaling
E 200 switches
E 200 switches
Isolator for panel installation onto DIN rail acc. to DIN EN 60715
Mounting depth: 70 mm
Mounting width: per pole = 17.5 mm = 1 module
Colour: grey, RAL 7035
Colour of switch lever: red RAL 3000 (r); grey RAL 7000 (g)
6
Special features
E 201 • Fast removal without dismantling of the busbar
• Captive screws with recessed/slotted head, Pozidriv size 2
• Add-on of up to 3 auxiliary contact S2C-H6R possible
• Integrated lay-on edge for labeling system ILS
• Locking device as accessory for unauthorized ON/OFF
• Approval: VDE, CCC, KEMA, EAC
Ordering details
Rated current: 80 A
Poles Rated Power Bbn Order details Price Weight Pack
voltage loss 4016779 1 1 piece unit
piece
V AC W EAN Type code Order code kg pc.
1NO 240 2.60 645737 E201/80g 2CDE281001R1080 0.095 10
1NO 240 2.60 645744 E201/80r 2CDE281001R0080 0.095 10
2NO 415 5.15 645911 E202/80g 2CDE282001R1080 0.190 5
2NO 415 5.15 645928 E202/80r 2CDE282001R0080 0.190 5
3NO 415 7.75 646093 E203/80g 2CDE283001R1080 0.290 3
3NO 415 7.75 646109 E203/80r 2CDE283001R0080 0.290 3
4NO 415 10.30 646277 E204/80g 2CDE284001R1080 0.390 2
4NO 415 10.30 646284 E204/80r 2CDE284001R0080 0.390 2
—
Command and signaling
E 463/3, E 480/3 switches
Technical features
Switching capacity 1.25 In; 1.1 Un; cosϕ = 0.6 according to DIN VDE 0632
Rated voltage 250/400 V a.c.
Connection cross section 1 mm2 stranded wire/0.5 mm2 wire up to 25 mm2
Pick-up torque 3 Nm max.
Positive opening according to DIN VDE 0113
6
(per pole) W V AC EAN Type code Order code piece kg pc.
63 5.4 250/400 932528 E 463/3-KB 2CCE160300R0131 0.190 1
E463/3-SL
63 5.5 250/400 932535 E 463/3-SL 2CCE160301R0131 0.195 1
80 9.9 250/400 932542 E 480/3-KB 2CCE180300R0141 0.210 1
—
Command and signaling
S800PV series 1500 switch disconnector
S802PV-M-H S800PV-SD
General Data
Tripping characteristics none none
Standards IEC / EN 60947-3 IEC / EN 60947-3 and
Annex D
Poles 2 (polarized) 2 ... 4
Rated current Ie A 32, 63, 100 32, 63, 125
6
Rated insulation voltage Ui acc. to IEC/EN V DC 1500 DC 1500
S800PV-SP 60664-1
Rated impulse withstand voltage Uimp. (1.2/50 µs) kV 8 8
Overvoltage category III* III*
Pollution degree 2 2
Suitability for isolation yes yes
Data acc. to IEC/EN 60947-3
Rated operational voltage Ue V DC 1000 V: 2-pole DC 800V: 2-pole
DC 1200V: 3-Pole
DC 1500 V: 4-pole
Min. operating voltage V - -
Rated short-term withstand current Icw kA 1.5 1.5
Rated short-circuit making capacity Icm kA 0.5 0.5
Utilisation category DC-21 A DC-21 A, DC-PV2
Electrical and Mechanical Endurance ops. 1500 electrical / 10000 32, 63 A: 1500 electrical
mechanical / 10000 mechanical
125 A: 1000 electrical /
8000 mechanical
Mechanical Data
Housing Material group I, RAL Material group I, RAL
7035 7035
Toggle black, lockable black, lockable
Classification acc. To NF F 126-101, NF F 16-102 - -
Protection degree acc. to EN 60529 IP20; IP40 (actuating IP20; IP40 (actuating
end only) end only)
Shock resistance acc. to IEC/EN 60068-2-30 IEC 61373 Cat. 1 Class IEC 61373 Cat. 1 Class
B, 5 g / 30 ms acc. To IEC B, 5 g / 30 ms acc. To
60068-27 Test Ea IEC 60068-27 Test Ea
Vibration resistance acc. to IEC/EN 60068-2-6 IEC 60068-2-6 Test Fc; IEC 60068-2-6 Test Fc;
2 - 13.2 Hz/1 mm 2 - 13.2 Hz/1 mm
13.2 - 100 Hz/0.7 g 13.2 - 100 Hz/0.7 g
with load 100 % x I e with load 100 % x Ie
Environmental conditions (damp heat) °C/RH 12 + 12 cycle with 12 + 12 cycle with
acc. to IEC/EN 60068-2-30 55 °C/90 - 96 % and 55 °C/90 - 96 % and
25 °C/95 - 100 % 25 °C/95 - 100 %
Environmental conditions (dry heat) °C/RH 16 hours 55 °C/2 hours 16 hours 55 °C/2 hours
acc. to IEC/EN 60068-2-2 Test B 70 °C with damp heat 70 °C with damp heat
55 % 55 %
Ambient temperature °C -25 … +60 -25 … +60
Storage temperature °C -40 … +70 -40 … +70
Installation
Terminal Failsafe cage or ringlug Failsafe cage or ringlug
terminal terminal
Connections (top/bottom) - Cu only mm2 1 … 50 stranded 1 … 50 stranded
1 … 70 flexible 1 … 70 flexible
Tightening torque Nm 3.5 3.5
in-Ibs. 31 31
Screwdriver POZI 2 POZI 2
Mounting any any
Mounting position any any
Supply any any
(taking into account the (taking into account the
polarization) polarization)
Dimensions and weight
Pole dimensions (H x L x W) mm 95 x 26.5 x 82.5 95 x 26.5 x 82.5
Pole weight g 240 240
*The pollution degree of the product, as defined in standard IEC 60947-1, is related to its micro environment, to which equip-
ment is exposed. It may be different from that of the macro-environment. According to where the equipment is located, the
pollution degree of the macro environment can be considered up to category IV, if protection is offered by means of such as an
adequate enclosure or internal heating to prevent absorption or condensation of moisture.
6/18 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
S800PV series 1500 switch disconnector
S800PV-SD
Function: switch disconnector for DC side isolation of PV systems.
Designed for PV installations of 1500 V DC.
Applications: Photovoltaic systems
Rated short-term withstand current, Icw 1.5 kA
6
1 3 5 7
2 4 6 8
6/19
—
Command and signaling
S800PV series 1500 switch disconnector
S800PV-M-H
Function: this polarized disconnector is designed to meet the requirements for photovoltaic
systems. Only 54 mm wide, voltage up to 1000 V d.c. and a rated current up to 100 A.
6
2 32 419035 S802PV-M32-H 2CCP247204R0001 0.43 1
63 419042 S802PV-M63-H 2CCP247205R0001 0.43 1
L- L+ + -
1 3 1 3
100 419301 S802PV-M100-H 2CCP247212R0001 0.43 1
2 4 2 4
- + L+ L-
6/20 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
E 210 switches
On-off switches
General
Overall depth 68 mm
Width 0.5 or 1 module (9 or 18 mm)
Colour grey, RAL 7035
Climatic resistance to IEC 60068-2-2 (dry heat)
6
Utilization category for E211 On-off switches (according to standard IEC 60947-3)
Type In Utilization category
DC-22 A AC-22 A
E211-16-... 16 A 50 VDC / 16 A 200 VDC / 1 A 400 VAC / 16 A
E211-25-... 25 A 50 VDC / 25 A 200 VDC / 2 A 400 VDC / 25 A
E211-32-...- 32 A 50 VDC / 32 A 200 VDC / 3 A 400 VDC / 32 A
6/21
—
Command and signaling
E 210 switches
Change over, Group and control switches, pushbuttons and indicator lights
Change over, Group and Control switches (E213; E214; E218)
Rated current In 16 A, 25 A
Rated voltage Un
in accordance with EN 250 VAC, 400 VAC
in accordance UL 508 240 VAC
6
Lowest operating voltage 24 VAC; 25 mA
Frequency 50/60 Hz
Switches sealable in the On and Off positions
Standards DIN EN 60669-1 *VDE 0632-1
UL 508
Approvals VDE; UL; GOST; CCC
Pushbuttons without and with LED (E215; E217)
Rated current In 16 A
Rated voltage Un
in accordance with EN 250 VAC
in accordance UL 508 240 VAC
Lowest operating voltage 24 VAC; 25 mA
LED voltage ranges 12-48 VAC / DC; 115-250 VAC; 60-220 VDC (Tolerance +/- 10%)
Frequency 50/60 Hz
Standards DIN EN 60669-1 *VDE 0632-1
UL 508
Approvals VDE; UL; GOST; CCC
Indicator lights (E219)
LED voltage ranges 12-48 VAC / DC; 115-250 VAC; 60-220 VDC (Tolerance +/- 10%)
Frequency 50/60 Hz
Insulation voltage 250 V
Rated impulse withstand voltage Uimp 4 kV
Dissipated power 0.47-1 W
Standards DIN EN 62094-1
UL 508
Approvals VDE; UL; GOST; *1
Indicator lights with 2 LEDs
LED voltage ranges 115-250 VAC; 12-48 VAC (tolerance +/- 10%)
Frequency 50/60 Hz
Insulation voltage 250 V
Rated impulse withstand voltage Uimp 4 kV
Dissipated power 0.8 W
Standards DIN EN 62094-1
Approvals VDE; GOST; *1
Indicator lights with 3 LEDs
LED voltage ranges 415/250 VAC (tolerance +/- 10%)
Frequency 50/60 Hz
Insulation voltage 250 V
Rated impulse withstand voltage Uimp 4 kV
Dissipated power 1.2 W
Standards DIN EN 62094-1
Approvals VDE; GOST; *1
—
Command and signaling
E 210 switches
These devices are specifically made for commanding loads and signaling electrical
conditions in any low-voltage switchboard. They are available in half module or 1 module, de-
pending on the contact-layout. The devices with indicator lights are equipped with a LED,
which grants an optimal illumination with very low consumption.
The functions of these devices are particularly switching, pushing and signaling electrical
6
E 211-16-10
General features
• Space-saving through 9 mm modules
• All terminals equipped with Pozidrive 1 screws
• Safe connection due to cage-clamp
• LED with bright colours and available in three different voltage ranges
• Different lens and button colours
• Compliance to international standards
E211-16-20
Rated current = 16 A
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
Rated current = 25 A
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
Rated current = 32 A
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
—
Command and signaling
E 210 switches
Rated current = 16 A
Contacts Rated Power LED Width Bbn Order details Price Weight Pack
voltage loss colour 7612270 1 piece 1 piece unit
6
V AC W mm EAN Type code Order code kg pc.
1 NO 250 0.50 yellow 9 938872 E211X-16-10 2CCA703100R0001 0.040 10
E211X-16-10
2 NO 250/400 1.00 yellow 18 938889 E211X-16-20 2CCA703110R0001 0.050 10
3 NO 250/400 1.50 yellow 18 938896 E211X-16-30 2CCA703115R0001 0.060 10
Rated current = 25 A
Contacts Rated Power LED Width Bbn Order details Price Weight Pack
voltage loss colour 7612270 1 piece 1 piece unit
Rated current = 16 A
Contacts Rated Power LED Width Bbn Order details Price Weight Pack
voltage loss colour 7612270 1 piece 1 piece unit
Rated current = 25 A
Contacts Rated Power LED Width Bbn Order details Price Weight Pack
voltage loss colour 7612270 1 piece 1 piece unit
E 213-16-002
6/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
E 210 switches
Rated current = 16 A
6
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
E214-16-101
V AC W mm EAN Type code Order code kg pc.
1 CO 250 0.32 9 938735 E214-16-101 2CCA703025R0001 0.041 10
2 CO 250 0.82 18 938742 E214-16-202 2CCA703030R0001 0.082 10
Rated current = 25 A
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
E214-16-202
Rated current = 16 A
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
Rated current = 25 A
Contacts Rated Power Width Bbn Order details Price Weight Pack
voltage loss 7612270 1 piece 1 piece unit
E 218-16-22
6/25
—
Command and signaling
E 210 pushbuttons
6
(Ranges: 12-48 V AC/DC; 115-250 V AC and 60-220 V DC).
E 215
Rated current = 16 A
Contacts Rated Power Button Width Bbn Order details Price Weight Pack
voltage loss colour 7612270 1 piece 1 piece unit
E 217
—
Command and signaling
E 210 pushbuttons
—
Command and signaling
E 210 indicator lights
6
Single indicator light - LED Voltage range = 115-250 V AC
E 219
Power LED Width Bbn Order details Price Weight Pack
loss colour 7612270 1 piece 1 piece unit
—
Command and signaling
E 210 indicator lights
—
Command and signaling
E 210 accessories
Padlock
Bbn Order details Price Weight Pack
7612270 1 piece 1 piece unit
—
Command and signaling
Installation contactors
6
ABB’s hum-free installation contactor designs now offer a wider range of ratings
from 16 A to 100 A. Widely used in buildings for switching and controlling lighting,
heating, ventilation, motor and pumps, the installation contactors take noise
reduction to a new level. With an innovative AC / DC coil design that eliminates hum,
a broad selection of common accessories as well as manual and automatic versions,
installation contactors offer peace of mind in noise-sensitive applications.
—
Command and signaling
Installation contactors
Features and benefits
Hum-free operation
With an innovative AC / DC design that eliminates
hum, the range meets the needs of applications
demanding silent operation, for example hotel
6
Comprehensive solution
ABB's ESB and EN installation contactors range
16 A
offers a complete solution from 16 A to 100 A,
offering an answer to all customer needs from
a single supplier.
With 16 A, 25 A and 100 A versions, tender
specifications can be met with competitive pricing.
100 A
6/31
—
Command and signaling
Installation contactors
Features and benefits
6
space in cabinets and money.
—
Command and signaling
Installation contactors
Easy installation and maintenance
ABB´s installation contactors come with many features that make installation and
maintenance easier. The mechanical Indicator with green and red color for status
indication ensures a quick diagnostic of the system. Also, some specialty types
feature a manual override functionality with a toggle switch to control independently
6
from control source. Accessories can be mounted tool-free on the contactor, for
example auxiliaries, space holders as well as security and safety covers.
Terminals IP20
—
Operation mode EN-versions
A1 Coil
A2 input
1 Main
contacts
2 output
—
Command and signaling
Installation contactors
Overview contactors
6
Type ESB16..N ESB20..N ESB25..N ESB40..N ESB63..N ESB100..N
EN20..N EN25..N EN40..N
AC-1/AC-7a (A) 16 20 25 40 63 100
Modular Width 1 1 2 3 3 3/6
Accessories
Auxiliary contact blocks 2 NO EH04-20N EH04-20N EH04-20N EH04-20N EH04-20N EH04-20N
1 NO + EH04-11N EH04-11N EH04-11N EH04-11N EH04-11N EH04-11N
1 NC
Distance piece up to 40 °C - - - - - -
*If several contactors are mounted adjacently and the duty time is longer than one hour, every second contactor needs a distance piece, Type ESB-DIS (1/2 module).
This is not necessary at an ambient temperature ≤ 40 °C .
6/34 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
Installation contactors
Overview accessories
Tool-free accessories
Speed up installation and maintenance time by
mounting accessories tool-free to the contactor.
Auxiliaries, security safety covers and space
6
Distance pieces
If the ambient temperature in your control cabi-
net exceeds 40 °C and the duty time is longer
> 40 °C than an hour, you need to use a distance piece be-
tween each second contactor for the ESB25..N to
ESB63..N.
Sealing covers
Protect the security of your employees/
customers´installation with sealing covers. They
are available in different sizes and can be clipped
on easily.
click!
Auxiliary contact blocks
ABB´s new range of auxiliary contact blocks
are mounted on the left side of the contactors.
Simply clip them on - no tools required!
Valuable inventory space can be saved with the
new auxiliary contact block which is designed to
fit all contactors of the range.
6/35
—
Command and signaling
Installation contactors
Ordering details ESB16..N - 16 A, AC-1 /AC-7a, AC/DC operated
The ESB16..N installation contactors are used to control single-phase loads up to 16 A and
can be operated by AC or DC voltages. These contactors are made for use in household ap-
plications as well as in industrial environment.
ESB16..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection.
• Various contact combinations and accessories are available.
6
Main Width(1) Rated Bbn Order details Price Weight Pack
contacts control 3471523 1 piece 1 piece unit
ESB16..N circuit
voltage(2)
V AC/DC EAN Type code Order code kg pc.
Single packaging
A1 1 3 24 004337 ESB16-20N-01 1SBE111111R0120 0.14 1
1
230 004481 ESB16-20N-06 1SBE111111R0620 0.14 1
A2 2 4
Multiple packaging
A1 1 3 24 004726 ESB16-20N-01 1SBE111111M0120 0.14 12
1
230 004870 ESB16-20N-06 1SBE111111M0620 0.14 12
A2 2 4
17.8 0.7''
3.35''
1.77''
85
45
6.8 0.27''
43.5 1.71''
58 2.28''
ESB16..N
—
Command and signaling
Installation contactors
Ordering details ESB20..N - 20 A, AC-1 /AC-7a, AC/DC operated
The ESB20..N installation contactors are used to control single-phase loads up to 20 A and
can be operated by AC or DC voltages. These contactors are made for use in household
applications as well as in industrial environment.
ESB20..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection.
• Various contact combinations and accessories are available.
6
Multiple packaging
A1 1 3 1 24 004962 ESB20-20N-01 1SBE121111M0120 0.14 12
17.8 0.7''
3.35''
1.77''
85
45
6.8 0.27''
43.5 1.71''
58 2.28''
ESB20..N
—
Command and signaling
Installation contactors
Ordering details ESB25..N - 25 A, AC-1/AC-7a, AC/DC operated
The ESB25..N installation contactors are used to control single and three-phases loads up to
25 A and can be operated by AC or DC voltages. These contactors are made for use in house-
hold applications as well as in industrial environment.
ESB25..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection.
• Various contact combinations and accessories are available.
6
Main Width(1) Rated Bbn Order details Price Weight Pack
contacts control 4013614 1 piece 1 piece unit
circuit
ESB25..N voltage(2)
V AC/DC EAN Type code Order code kg pc.
Single packaging
A1 1 3 5 7 (13) 2 24 523977 ESB25-40N-01 1SAE231111R0140 0.245 1
230...240 524257 ESB25- 1SAE231111R0640 0.235 1
A2 2 4 6 8 (14) 40N-06
A1 R1 R3 R5 R7 2 24 523915 ESB25-04N-01 1SAE231111R0104 0.245 1
230...240 524196 ESB25-04N-06 1SAE231111R0604 0.235 1
A2 R2 R4 R6 R8
A2 2 R4 R6 8
230...240 524226 ESB25-22N-06 1SAE231111R0622 0.235 1
A1 1 R3 5 7 2 24 523960 ESB25-31N-01 1SAE231111R0131 0.245 1
230...240 524240 ESB25-31N-06 1SAE231111R0631 0.235 1
A2 2 R4 6 8
Multiple packaging
A1 1 3 5 7 (13) 2 24 519420 ESB25-40N-01 1SAE231111M0140 0.245 6
230...240 519703 ESB25- 1SAE231111M0640 0.235 6
A2 2 4 6 8 (14) 40N-06
A1 R1 R3 R5 R7 2 24 519369 ESB25-04N-01 1SAE231111M0104 0.245 6
230...240 519642 ESB25-04N-06 1SAE231111M0604 0.235 6
A2 R2 R4 R6 R8
36 1.42''
85 3.35''
45 1.77''
6.8 0.27''
43.5 1.71''
58 2.28''
ESB25..N
—
Command and signaling
Installation contactors
Ordering details ESB40..N - 40 A, AC-1/AC-7a, AC/DC operated
The ESB40..N installation contactors are used to control single and three-phases loads up
to 40 A and can be operated by AC or DC voltages. These contactors are made for use in
household applications as well as in industrial environment.
ESB40..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection.
• Various contact combinations and accessories are available.
6
Multiple packaging
A1 1 3 5 7 (13) 3 24 520075 ESB40-40N-01 1SAE341111M0140 0.405 4
230 520266 ESB40-40N-06 1SAE341111M0640 0.405 4
A2 2 4 6 8 (14)
54 2.13''
3.35''
45 1.77''
85
6.8 0.27''
43.5 1.71''
58 2.28''
ESB40..N
—
Command and signaling
Installation contactors
Ordering details ESB63..N - 63 A, AC-1/AC-7a, AC/DC operated
The ESB63..N installation contactors are used to control single and three-phases loads up
to 63 A and can be operated by AC or DC voltages. These contactors are made for use in
household applications as well as in industrial environment.
ESB63..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection.
• Various contact combinations and accessories are available.
6
Main Width(1) Rated Bbn Order details Price Weight Pack
contacts control 4013614 1 piece 1 piece unit
circuit
voltage(2)
ESB63..N
V AC/DC EAN Type code Order code kg pc.
Single packaging
A1 1 3 5 7 (13) 3 24 525278 ESB63-40N-01 1SAE351111R0140 0.405 1
A2 2 R4 6 8
A2 2 4 6
Multiple packaging
A1 1 3 5 7 (13) 3 24 520716 ESB63-40N-01 1SAE351111M0140 0.405 4
A2 2 R4 6 8
A2 2 4 6
54 2.13''
3.35''
45 1.77''
85
6.8 0.27''
43.5 1.71''
58 2.28''
ESB63..N
—
Command and signaling
Installation contactors
Ordering details ESB100..N - 100 A, AC-1/AC-7a, AC/DC operated
The ESB100..N installation contactors are used to control single and three-phases loads up
to 100 A and can be operated by AC or DC voltages. These contactors are made for use in
household applications as well as in industrial environment.
ESB100..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection.
• Various contact combinations and accessories are available.
6
Main Width (1) Rated Bbn Order details Price Weight Pack
contacts control 4013614 1 piece 1 piece unit
circuit
ESB100-20N voltage
V AC/DC EAN Type code Order code kg pc.
Single packaging
A1 1 3 5 7 (13) 6 24 533112 ESB100-40N-01 1SAE661111R0140 0.405 1
A2 2 4
230 533037 ESB100-20N-06 1SAE361111R0620 0.81 1
Multiple packaging
A1 1 3 3 24 533235 ESB100-20N-01 1SAE361111M0120 1.62 2
ESB100-40N
A2 2 4
230 533259 ESB100-20N-06 1SAE361111M0620 1.62 2
54 2.13''
3.35''
1.77''
85
45
6.8 0.27''
43.5 1.71''
58 2.28''
ESB100 -20N
108 4.25''
3.35''
1.77''
85
45
6.8 0.27''
43.5 1.71''
58 2.28''
ESB100 - 40N
—
Command and signaling
Installation contactors
Ordering details EN20N -20 A, manually/automatic operated
The EN20..N installation contactors are used to control single-phase loads up to 20 A and
can be operated by AC or DC voltages. They have a built-in toggle switch to be operated
manually or automatically. These contactors are made for use in household applications as
well as in industrial environment.
EN20..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection and
6
manual override.
• Various contact combinations and accessories are available.
EN20..N Main Width(1) Rated Bbn Order details Price Weight Pack
contacts control 3471523 1 piece 1 piece unit
circuit
voltage (1)
V AC/DC EAN Type code Order code kg pc.
Single packaging
A1 1 3 1 24 004689 EN20-20N-01 1SBE122111R0120 0.14 1
Multiple packaging
A1 1 3 1 24 005426 EN20-20N-01 1SBE122111M0120 0.14 12
17.8 0.7''
45
3.35''
1.77''
85
EN20..N
—
Command and signaling
Installation contactors
Ordering details EN25..N, manually/automatic operated
The EN25..N installation contactors are used to control single- and three-phase loads up to
25 A and can be operated by AC or DC voltages. They have a built-in toggle switch to be op-
erated manually or automatically. These contactors are made for use in household applica-
tions as well as in industrial environment.
EN25..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection and
6
manual override.
• Various contact combinations and accessories are available.
EN25..N Main Width(1) Rated Bbn Order details Price Weight Pack
contacts control 4013614 1 piece 1 piece unit
circuit
voltage
Multiple packaging
A1 1 3 5 7 (13) 2 24 519871 EN25-40N-01 1SAE232111M0140 0.250 6
36 1.42''
2.87''
1.77''
3.35''
45
72.8
85
6.8 0.27''
43.5 1.71''
58 2.28''
EN25..N
—
Command and signaling
Installation contactors
Ordering details EN40..N, manually/automatic operated
The EN40..N installation contactors are used to control single- and three-phase loads up to
40 A and can be operated by AC or DC voltages. They have a built-in toggle switch to be op-
erated manually or automatically. These contactors are made for use in household applica-
tions as well as in industrial environment.
EN40..N series is providing the following benefits:
• Hum-free operation, low power consumption and integrated overvoltage protection and
6
manual override.
• Various contact combinations and accessories are available.
EN40..N Main Width(1) Rated Bbn Order details Price Weight Pack
contacts control 4013614 1 piece 1 piece unit
circuit
voltage(2)
A1 1 R3 5 7
3 24 524936 EN40-31N-01 1SAE342111R0131 0.410 1
A1 1 3 5
3 230 525124 EN40-30N-06 1SAE342111R0630 0.410 1
A2 2 4 6
A1 1 3
3 230 525117 EN40-20N-06 1SAE342111R0620 0.375 1
A2 2 4
Multiple packaging
A1 1 3 5 7 (13) 3 24 520389 EN40-40N-01 1SAE342111M0140 0.410 4
A1 1 R3 5 7
3 24 520372 EN40-31N-01 1SAE342111M0131 0.410 4
A1 1 3 5
3 230 520563 EN40-30N-06 1SAE342111M0630 0.410 4
A2 2 4 6
A1 1 3
3 230 520556 EN40-20N-06 1SAE342111M0620 0.375 4
A2 2 4
54 2.13''
85 3.35''
45 1.77''
6.8 0.27''
43.5 1.71''
58 2.28''
EN40..N
—
Command and signaling
Installation contactors
Ordering details installation contactors accessories
Suitable for Auxiliary contacts Bbn Order details Price Weight Pack
4013614 1 piece 1 piece unit
ESB25..N,
EH04-20N
ESB40..N,
34
ESB63..N, 22
ESB100..N, 23 527821 EH04-20N 1SAE901901R1020 0.040 1
EN20..N, 33
EN25..N,
EN40..N
34
24
Multiple packaging
ESB16..N, 21 528019 EH04-11N 1SAE901901M1011 0.040 6
ESB20..N, 33
ESB25..N,
ESB40..N,
34
ESB63..N, 22
ESB100..N, 23 528026 EH04-20N 1SAE901901M1020 0.040 6
EN20..N, 33
EN25..N,
EN40..N
34
24
Accessories
ESB-SPK40/63 9 0.35''
3.35''
2.72''
1.77''
2.09''
53
45
69
85
6.8 0.27''
43.5 1.71''
58 2.28''
EH04..N
—
Command and signaling
E290 Latching relays
General
Overall depth 68 mm
Overall width 1 module (18 mm)
Color grey, RAL 7035
6
Climate resistance in accordance with IEC 60068-2-2 (dry heat)
—
Command and signaling
E290 Latching relays
Connecting terminals solid from 1x1 mm2 to 1x10 mm2 or 2x2.5 mm2
flexible from 1x0.75 mm2 to 1x16 mm2 (Cu)
with end ferrule or pin cable lug
Control Circuit
Rated control voltages Un
AC: 8 V; 12 V; 24 V; 48 V; 115 V; 230 V
* for 50 Hz devices
DC: –; –; 12 V*; 24 V; 60 V*; 110 V* only
AC/DC ratio 1) 1: 0.5 (not available for 8 VAC and 12 VAC coils)
Operation limits +/- 10% = 0.9 - 1.1 x Un
Minimum command duration 50 ms
Max. switching operations 15 x per min. at In 16 A; 8 x per min. at In 32 A
switching noise 60 dB (A) (distance 1 m)
Max. number of illuminated buttons (0.6 mA) (see table on page 16)
Max. glow lamp current parallel to the 230 V control buttons 5 mA
Product type Control voltage Coil consumption ave- Control voltage Coil consumption
rage pull-in current average pull-in current
V AC A V DC A
E290
230 0.062 110* 0.057*
115 0.070 60* 0.105*
48 0.212 24 0.207
24 0.434 12* 0.558*
12 1.263 – –
8 2.048 – –
E291S*
230 0.051 110 0.047
24 0.378 12 0.355
12 0.803 – –
8 1.088 – –
E294
230 0.120 – –
24 0.684 – –
1) Coil supply voltage: All E290 50Hz devices can be supplied with AC or DC control voltage.
The ratio of 1 : 0.5 applies, i.e. a 230 VAC coil can also be used for 110 VDC. (See Ordering data.)
—
Command and signaling
E290 Latching relays
6
Max. no. attachable (additional main contacts) 1 unit (attachable on the right side of the main module)
Contact configurations 1CO; 2NO; 1NO+1NC
Max. DC current per contact with 24 VDC 8A
Min. switching load (for 50 Hz devices only) 24 V; 10 mA
E299-… Auxiliary Contacts
Max. no. attachable (signaling or control contacts) 1 unit (attachable on the right side of the main module)
Number of contacts 1 NO + 1 NC; 2 NO
Min. switching load 24 V, 10 mA
Max. current per contact with AC 5.0 A
Max. current per contact with 24 VDC 5.0 A
—
Command and signaling
E297 Installation relay
General
Overall depth 68 mm
Overall width 1 module (18 mm)
Colour grey, RAL 7035
6
—
Command and signaling
E297 Installation relay
Application categories
Switching capacity AC-1 (based on EN 60947) 16 A
in accordance with AC-5b (based on EN 60947) 5A
AC-7a (based on EN 61095) 16 A
6
AC-7c (based on EN 61095) 5A
Connector cross-sections
Main connecting terminals solid from 1 x 1 mm2 to 1 x 10 mm2 or 2 x 2.5 mm2
flexible from 1 x 0.75 mm2 up to 1 x 6 mm2 (Cu)
with end ferrule or pin cable lug
Control circuit
Coil rated voltages Un AC/DC 8 VAC; 12 VAC; 24 VAC/24 VDC; 48 VAC/48 VDC;
115 VAC/110 VDC; 230 VAC
AC/DC ratio 3) 1:1
Operation limits +/- 10 % = 0.9 - 1.1 x Un
Switching noise 60 dB (A) (distance 1 m)
Max. switching operations 15 x per min. at In 16 A
Coil power loss
AC DC
Pick up < 2.8 VA < 2.0 W
Holding < 2.6 VA < 1.8 W
—
Command and signaling
E290 Latching relays
Latching Relay
This 18 mm wide DIN rail mounted device is designed for direct installation in main distribution
or sub-distribution systems (mounted on 35 mm DIN mounting rails). The devices are activated
by means of control pulses and guarantee energy-optimized lighting control. As a rule, installa-
tions with latching relays are used where the lighting control system can be operated from at
least three points in different locations. Those latching relays are designed for a rated current of
6
16 A or 32 A.
E290
Standard number of contacts:
1 NO contact, 2 NO contacts or 1 NO contact + 1 NC contact
The number of switching contacts can be increased by a maximum of two main contacts using a
snap-on main module (E292-..-..). As a result, up to four lighting sets can be switched by a single
device.
A signaling and/or indicating facility can be created using the additional snap-on auxiliary con-
tact module (E299-11).
The various standard AC/DC coil voltages complete the comprehensive and interesting product
range. The additional devices can be snapped onto the latching relay on the left or right side.
Rated current = 16 A
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
1NO 0.32 18 8VAC 939558 E290-16-10/8 2TAZ312000R2061 0.114 10
0.32 18 12VAC 939565 E290-16-10/12 2TAZ312000R2051 0.114 10
0.32 18 24VAC/12VDC 939572 E290-16-10/24 2TAZ312000R2041 0.114 10
0.32 18 48VAC/24VDC 939589 E290-16-10/48 2TAZ312000R2031 0.114 10
0.32 18 115VAC/60VDC 939596 E290-16-10/115 2TAZ312000R2021 0.114 10
0.32 18 230VAC/110VDC 939602 E290-16-10/230 2TAZ312000R2011 0.114 10
A
Rated current = 32 A
0 AB
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
1NO 1.20 18 8VAC 939619 E290-32-10/8 2TAZ322000R2061 0.114 10
1.20 18 12VAC 939626 E290-32-10/12 2TAZ322000R2051 0.114 10
1.20 18 24VAC/12VDC 939633 E290-32-10/24 2TAZ322000R2041 0.114 10
1.20 18 48VAC/24VDC 939640 E290-32-10/48 2TAZ322000R2031 0.114 10
1.20 18 115VAC/60VDC 939657 E290-32-10/115 2TAZ322000R2021 0.114 10
1.20 18 230VAC/110VDC 939664 E290-32-10/230 2TAZ322000R2011 0.114 10
A
Rated current = 16 A
0 AB
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
2NO 0.64 18 8VAC 939671 E290-16-20/8 2TAZ312000R2062 0.122 10
0.64 18 12VAC 939688 E290-16-20/12 2TAZ312000R2052 0.122 10
0.64 18 24VAC/12VDC 939695 E290-16-20/24 2TAZ312000R2042 0.122 10
0.64 18 48VAC/24VDC 939701 E290-16-20/48 2TAZ312000R2032 0.122 10
0.64 18 115VAC/60VDC 939718 E290-16-20/115 2TAZ312000R2022 0.122 10
0.64 18 230VAC/110VDC 939725 E290-16-20/230 2TAZ312000R2012 0.122 10
A
0 AB
—
Command and signaling
E290 Latching relays
Rated current = 32 A
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
2NO 2.40 18 8VAC 939732 E290-32-20/8 2TAZ322000R2062 0.122 10
2.40 18 12VAC 939749 E290-32-20/12 2TAZ322000R2052 0.122 10
6
2.40 18 24VAC/12VDC 939756 E290-32-20/24 2TAZ322000R2042 0.122 10
2.40 18 48VAC/24VDC 939763 E290-32-20/48 2TAZ322000R2032 0.122 10
2.40 18 115VAC/60VDC 939770 E290-32-20/115 2TAZ322000R2022 0.122 10
2.40 18 230VAC/110VDC 939787 E290-32-20/230 2TAZ322000R2012 0.122 10
A
Rated current = 16 A 0
B
AB
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
1NO+1NC 0.50 18 8VAC 939794 E290-16-11/8 2TAZ312000R2063 0.122 10
0.50 18 12VAC 939800 E290-16-11/12 2TAZ312000R2053 0.122 10
0.50 18 24VAC/12VDC 939817 E290-16-11/24 2TAZ312000R2043 0.122 10
0.50 18 48VAC/24VDC 939824 E290-16-11/48 2TAZ312000R2033 0.122 10
0.50 18 115VAC/60VDC 939831 E290-16-11/115 2TAZ312000R2023 0.122 10
0.50 18 230VAC/110VDC 939848 E290-16-11/230 2TAZ312000R2013 0.122 10
A
0 Rated
AB current = 32 A
B
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
1NO+1NC 1.20 18 8VAC 939855 E290-32-11/8 2TAZ322000R2063 0.122 10
1.20 18 12VAC 939862 E290-32-11/12 2TAZ322000R2053 0.122 10
1.20 18 24VAC/12VDC 939879 E290-32-11/24 2TAZ322000R2043 0.122 10
1.20 18 48VAC/24VDC 939886 E290-32-11/48 2TAZ322000R2033 0.122 10
1.20 18 115VAC/60VDC 939893 E290-32-11/115 2TAZ322000R2023 0.122 10
1.20 18 230VAC/110VDC 939909 E290-32-11/230 2TAZ322000R2013 0.122 10
A
0 AB
—
Command and signaling
E290 Latching relays
2 NO contacts
E291S
Rated current = 16 A
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 piece unit
0 AB
E292 B
Group Module
18 939466 E295-GM 2TAZ310002R1000 0.059 10
E295 Compensator
18 939473 E296-CP 2TAZ310003R1000 0.055 10
—
Command and signaling
E290 60Hz Mechanical latching relay – Ordering data
Cont. Rated Power Width Coil control voltage Ordering data Bbn Weight Pack.
config. Voltage loss 7612271 per unit unit
Rated current = 16 A
6
1NO 250 0.32 18 230VAC E290-16-10/230-60 2TAZ352000R2011 503901 0.111 10
1NO 250 0.32 18 115VAC E290-16-10/115-60 2TAZ352000R2021 504328 0.111 10
1NO 250 0.32 18 48VAC E290-16-10/48-60 2TAZ352000R2031 504359 0.111 10
1NO 250 0.32 18 24VAC E290-16-10/24-60 2TAZ352000R2041 504380 0.111 10
1NO 250 0.32 18 24VDC E290-16-10/24DC 2TAZ352000R2071 504472 0.111 10
1NO 250 0.32 18 12VAC E290-16-10/12-60 2TAZ352000R2051 504410 0.111 10
1NO 250 0.32 18 8VAC E290-16-10/8-60 2TAZ352000R2061 504441 0.111 10
2NO 250 0.64 18 230VAC E290-16-20/230-60 2TAZ352000R2012 503918 0.122 10
2NO 250 0.64 18 115VAC E290-16-20/115-60 2TAZ352000R2022 504335 0.122 10
2NO 250 0.64 18 48VAC E290-16-20/48-60 2TAZ352000R2032 504366 0.122 10
2NO 250 0.64 18 24VAC E290-16-20/24-60 2TAZ352000R2042 504397 0.122 10
2NO 250 0.64 18 24VDC E290-16-20/24DC 2TAZ352000R2072 504489 0.122 10
2NO 250 0.64 18 12VAC E290-16-20/12-60 2TAZ352000R2052 504427 0.122 10
2NO 250 0.64 18 8VAC E290-16-20/8-60 2TAZ352000R2062 504458 0.122 10
1NO+1NC 250 0.50 18 230VAC E290-16-11/230-60 2TAZ352000R2013 504311 0.121 10
1NO+1NC 250 0.50 18 115VAC E290-16-11/115-60 2TAZ352000R2023 504342 0.121 10
1NO+1NC 250 0.50 18 48VAC E290-16-11/48-60 2TAZ352000R2033 504373 0.121 10
1NO+1NC 250 0.50 18 24VAC E290-16-11/24-60 2TAZ352000R2043 504403 0.121 10
1NO+1NC 250 0.50 18 24VDC E290-16-11/24DC 2TAZ352000R2073 504496 0.121 10
1NO+1NC 250 0.50 18 12VAC E290-16-11/12-60 2TAZ352000R2053 504434 0.121 10
1NO+1NC 250 0.50 18 8VAC E290-16-11/8-60 2TAZ352000R2063 504465 0.121 10
Rated current = 32 A
1NO 250 1.20 18 230VAC E290-32-10/230-60 2TAZ362000R2011 504502 0.111 10
1NO 250 1.20 18 115VAC E290-32-10/115-60 2TAZ362000R2021 504533 0.111 10
1NO 250 1.20 18 48VAC E290-32-10/48-60 2TAZ362000R2031 504564 0.111 10
1NO 250 1.20 18 24VAC E290-32-10/24-60 2TAZ362000R2041 504595 0.111 10
1NO 250 1.20 18 12VAC E290-32-10/12-60 2TAZ362000R2051 504625 0.111 10
1NO 250 1.20 18 8VAC E290-32-10/8-60 2TAZ362000R2061 504656 0.111 10
2NO 250 2.40 18 230VAC E290-32-20/230-60 2TAZ362000R2012 504519 0.123 10
2NO 250 2.40 18 115VAC E290-32-20/115-60 2TAZ362000R2022 504540 0.123 10
2NO 250 2.40 18 48VAC E290-32-20/48-60 2TAZ362000R2032 504571 0.123 10
2NO 250 2.40 18 24VAC E290-32-20/24-60 2TAZ362000R2042 504601 0.123 10
2NO 250 2.40 18 12VAC E290-32-20/12-60 2TAZ362000R2052 504632 0.123 10
2NO 250 2.40 18 8VAC E290-32-20/8-60 2TAZ362000R2062 504663 0.123 10
1NO+1NC 250 1.20 18 230VAC E290-32-11/230-60 2TAZ362000R2013 504526 0.121 10
1NO+1NC 250 1.20 18 115VAC E290-32-11/115-60 2TAZ362000R2023 504557 0.121 10
1NO+1NC 250 1.20 18 48VAC E290-32-11/48-60 2TAZ362000R2033 504588 0.121 10
1NO+1NC 250 1.20 18 24VAC E290-32-11/24-60 2TAZ362000R2043 504618 0.121 10
1NO+1NC 250 1.20 18 12VAC E290-32-11/12-60 2TAZ362000R2053 504649 0.121 10
1NO+1NC 250 1.20 18 8VAC E290-32-11/8-60 2TAZ362000R2063 504670 0.121 10
6/54 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
E290 60Hz Mechanical latching relay – Ordering data
Cont. Rated Power Width Coil control voltage Ordering data Bbn Weight Pack.
config. Voltage loss 7612270 per unit unit
Group Module
18 E295-GM 2TAZ310002R1000 939466 0.059 10
Compensator
18 E296-CP 2TAZ310003R1000 939473 0.055 10
—
Command and signaling
E297 Installation relay
6
Standard number of contacts:
1 NO contact, 2 NO contacts or 1 NO contact + 1 NC contact
E297
In addition, the number of main contacts can be increased to four contact lines using the
snap-on E298 Main contact module so that three different groups of loads can be switched
and controlled safely.
The various AC/DC coil voltages complete the comprehensive and interesting product range.
The additional devices can be snapped onto the installation relay on the right side.
Rated current = 16 A
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
1NO 0.50 18 8VAC 940004 E297-16-10/8 2TAZ311000R2061 0.113 10
0.50 18 12VAC 940011 E297-16-10/12 2TAZ311000R2051 0.113 10
0.50 18 24VAC/24VDC 940028 E297-16-10/24 2TAZ311000R2041 0.113 10
0.50 18 48VAC/48VDC 940035 E297-16-10/48 2TAZ311000R2031 0.113 10
0.50 18 115VAC/110VDC 940042 E297-16-10/115 2TAZ311000R2021 0.113 10
0.50 18 230VAC 940059 E297-16-10/230 2TAZ311000R2011 0.113 10
A
0 AB
Rated current = 16 A
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 piece unit
0 AB
Rated current = 16 A
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 unit
piece
[W] [VAC/VDC] EAN Type code Order code kg. pc.
2NO 1.00 18 8VAC 940127 E297-16-20/8 2TAZ311000R2062 0.121 10
1.00 18 12VAC 940134 E297-16-20/12 2TAZ311000R2052 0.121 10
1.00 18 24VAC/24VDC 940141 E297-16-20/24 2TAZ311000R2042 0.121 10
1.00 18 48VAC/48VDC 940158 E297-16-20/48 2TAZ311000R2032 0.121 10
1.00 18 115VAC/110VDC 940165 E297-16-20/115 2TAZ311000R2022 0.121 10
1.00 18 230VAC 940172 E297-16-20/230 2TAZ311000R2012 0.121 10
A
0 AB
B
6/56 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
E297 Installation relay
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 piece unit
E298
[W] [VAC/VDC] EAN Type code Order code kg. pc.
2NO 0.64 9 939961 E298-16-20 2CCA704320R0001 0.045 10
1NO+1NC 0.32 9 939954 E298-16-11 2CCA704321R0001 0.045 10
1CO 0.32 9 939978 E298-16-001 2CCA704322R0001 0.045 10
Contact Power Width Coil control Bbn Order details Price Weight Pack
config. loss [mm] voltage 7612270 1 piece unit
E299
Auxiliary Contact for Latching and Installation relays
Rated current = 5 A
1NO+1NC 0.10 9 939985 E299-11 2CCA704340R0001 0.045 10
2NO 0.10 9 E200-20 2CCA704341R0001 0.045 10
—
Notes
6
6/58 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
E 260 latching relays
Technical features
E 260/E 260 C
Rated load at 250 V AC 8A
Incandescent lamp load 1000 W
Fluorescent lamp load in twin-lamp circuit 1000 W
Fluorescent lamp load shunt compensated 350 W
6
Control current when controlled centrally 230 V AC 8 mA, after 10s 3 mA ± 20 %
—
Command and signaling
E 260 latching relays
6
1 NO+1 NC 2.4 (3.5) 57595 9 E 266-24 2CDE444000R0301 0.096 1
2 NO 2.4 (3.5) 57593 5 E 262-24 2CDE442000R0301 0.096 1
E 260
—
Command and signaling
STD50 dimmers
Technical features
Rated voltage 230 V ~ 50 Hz
Ambient temperature 0 °C to + 35 °C
Interference suppression CE
STD 50
Dimmer for brightness control of filament lamps , 230 V tungsten halogen lamps,
lv halogen lamps with conventional transformers (phase control)
Description/ Power loss Bbn Order details Price Weight Pack
application 4016779 1 piece 1 piece unit
Dimmer for brightness control of filament lamps , 230 V tungsten halogen lamps,
lv halogen lamps with ABB electronic transformers (reverse phase)
Description/ Power loss Bbn Order details Price Weight Pack
application 4016779 1 piece 1 piece unit
Electronic potentiometer for electronic control gear with control input 0/1 - 10 V DC, control current 50 mA DC
Rated current (terminal 3 and 4) 4 A cosϕ = 0.9; switching capacity 700 VA
Description/ Power loss Bbn Order details Price Weight Pack
application 4016779 1 piece 1 piece unit
—
Command and signaling
STD universal dimmer for phase control and reverse phase control
Technical features
Rated voltage 230 V ~ ± 10%, 50/60 Hz
Rated current STD U 2.17 A
STD E 1.83 A
Max. connected load U 500 W/VA
E 420 W/VA
6
Power extension 1 U + max. 6 E/phase = > max. 3 kVA
Min. connected load STD U 60 W/VA
STD-500 U
STD E 200 W/VA
Max. line length 100 m pushbutton cable, 2 m data line
Interference suppression CE
Ambient temperature 0 ... + 45 °C, higher temperatures reduce the power
Electronic protection against short circuit, overload, excessive temperature, automatic load
recognition, soft-OFF function optional, memory function, minimum brightness control,
visual overload indication.
The STD-500 U dimmer can be operated by one or more unlit pushbuttons (N- or
L-controlled) or via a data line:
• EIB control element SB/S
• Powernet control element PSB
Power unit STD-420 E is used to boost the connected load and is controlled exclusively by
the preset command of the STD-500 U dimmer. The parallel connection of the outputs of the
universal high-performance dimmer and the pertaining power extensions (up to 6 units; con-
nection with enclosed RJ 12 line cut to length) allow for a dimming power of 3,000 W/VA max
at one load line.
Not suitable for dimming fluorescent lamps, transformers with current monitor and
high-reactance transformers.
Note: Load and control cables must not be laid in one cable
6/62 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
STD universal dimmer for phase control and reverse phase control
Application
6
Remove dimmer cap and snap on operation element to provide for control of dimmer with
central pushbutton or rotary operation. Local operation elements are still active.
Apart from the manual local control feature, the timer also allows for time-programmed
operations.
Product advantages
• Reliable and comfortable dimming of LED lamps
• Tuned to replacement lamps (retrofit LEDs)
• Brightness regulator downward compatible also suitable for conventional incandescent
lamps, 230 V halogen lamps and low-voltage halogen lamps with conventional inductive
6586-500 and electronic transformers.
• Touch-dimmer with local operation
• Adjustable minimum / maximum brightness Staircase light function with automatic
switch-off function and pre-warning function according to DIN 18015-2
• Perfect function and comfortable operation
• Harmonious and flicker-free dimming process
• No humming or buzzing due to transistor technology
• Numerous practical special functions
• Extremely compact construction as MDRC device (1 MW)
Tecnical features
Max. connected load 2 - 100 W/VA (Retrofit-LED-load).
Max. connected load 10 - 200 W/VA (Non-LED-load).
Rated voltage 230 V~, +10 % / -10 %, 50 Hz - 60 Hz
Ambient temperature 0 °C bis 35 °C
Standards IEC 60669-2-1, British Standard EN 60669-2-1
—
Command & Signalling
Busch-Dimmer®
Busch-Dimmer® 1) 2) 3) 4) 5)
MDRC, LED, 20-800 W
Touch dimmer with local operation.
Optimised for dimming of retrofit LED lamps (LEDi).
For dimmable Retrofit-LEDs (LEDi).
6
For dimmable Retrofit-LEDs (LEDi) with conventional or
electronic transformers.
For incandescent lamps, 230V tungsten halogen lamps
and lowvoltage halogen lamps with conventional
transformers or electronic transformers and dimmable
halogen energy-saving lamps.
Mix operaton of LEDi with conventional loads possible.
With the following functions: memory, snooze,
wake-up, children's room, central off, cleaning light and
time function.
For staircase lighting control with automatic switch-off
and warning function according to DIN 18015-2.
Supports the adherence to the energy saving ordinance
(EnEV 2014).
Low-noise level by MOSFET transistors.
With electronic short-circuit protection.
With electronic overload protection.
With manually adjustable operating mode: trailing /
leading edge control.
With adjustable minimum/maximum brightness.
With light value storage.
Operation also possible via conventional push buttons
(2020 US, 2021/6 UK).
Extension unit input for short switching pulses
(push-button) and continuous contact (switch/timer).
Extension unit input designed as wide voltage input
(8-230 V; AC/DC); galvanic isolation.
Nominal voltage: 110 - 230 V, +10% / -10%
Rated frequency: 50 Hz/60 Hz
Nominal power: 20 - 300 W/VA (leading edge control
in 230 V~ networks)
Nominal power: 40 - 800 W/VA (trailing edge control
in 230 V~ networks)
Nominal power: 20 - 150 W/VA (leading edge control
in 110/127 V~ networks)
Nominal power: 40 - 400 W/VA (trailing edge control
in 110/127 V~ networks)
Rated voltage: 110 - 230 V, +10 % / -10 %
Temperature range (Device): 0 °C to 35 °C
Module width: 4 MW
IEC 60669-2-1, British Standard EN 60669-2-1
—
Command and signaling
Transformers selection table
Bell
transformers
for discontinuous use
6
Series TM TS
Reference standard IEC EN 61558-2-8 IEC EN 61558-2-8
Secondary Rated
Use Type Solution
voltage power
TM-C
START
Non-inherently short-circuit
Discontinuous SELV 8-24 VA TS
proof bell transformer
—
Command and signaling
Transformers selection table
6
TS-C TM-C TM-S TM-I
IEC EN 61558-2-6 CEI EN 61558-2-2 CEI EN 61558-2-2 CEI EN 61558-2-2
CEI EN 61558-2-6 CEI EN 61558-2-4
Non-inherently short-circuit proof Non-short-circuit proof control Non-short-circuit-proof control Non-short-circuit-proof control
transformer a and safety transformer a and isolating transformer a
n
10, 16, 25, 40, 63, 100 VA 50 to 2500 VA 50 to 2500 VA 50 to 2500 VA
Continuous Continuous Continuous Continuous
230 V a.c. 230/400 V a.c. 230/400V a.c. 230/400 V a.c.
n n n
n n n n
n n
2 modules [10 VA] See overall dimensions 13/60 See overall dimensions 13/60 See overall dimensions 13/60
3 modules [16 VA]
4 modules [25 VA, 40 VA]
5 modules [63 VA]
6 modules [100 VA]
Transformers for supplying extra low voltage, suitable for loads that require a discontinuous supply, in particular doorbells
and chimes. The primary and secondary circuits are perfectly isolated and separated.
Reference standard: IEC EN 61558-2-8
Transformer for supplying control circuits, for example commands, signaling, interlocks, etc.
Reference standard: CEI EN 61558-2-2
Isolation transformer for supplying safety extra low voltage circuits (<50 V on no load). Accidental contact with the
secondary winding phases can be withstood without any danger.
Reference standard: CEI EN 61558-2-6
—
Command and signaling
Control, isolating and safety transformers selection table
a FUSES
- Gauge ≤ 6.3 A use aM fuses with high breaking capacity and IEC601266-compliant
- Gauge > 6.3 A use gG fuses IEC60269-2 or IEC60269-3-compliant
b TM-S 50/24-48 P complies with IEC EN 61558-2-4 on the secondary circuit at 48 V and with IEC EN 61558-2-6 on the secondary circuit at 24 V
6/67
—
Command and signaling
TM-C, TM-S, TM-I control, isolating and safety transformers
Technical characteristics
TM-C TM-S TM-I
Rated primary voltage Un [V] 230/400 a.c. 230/400 a.c. 230/400 a.c.
Primary voltage adjustment No Yes Yes
outlets ±15 V
TM [°C] 40 40 40
Max ambient temperature c
6
Rated secondary voltage Un [V] 12-24, 115-230 a.c. 12-24, 24-48 a.c. b 115-230 a.c.
Rated frequency [Hz] 50/60 50/60 50/60
Isolation voltage between [kV] 3.5 4.8 4.8
primary and secondary
Rated powers [VA] 50-2500 50-2500 50-2500
Primary cable section (Ø max) [mm ] 2
6 6 6
Operating temperature [°C]
Approvals ENEC (Up to 1000 ENEC (Up to 1000 ENEC (Up to 1000
VA), UR, CSA VA), UR, CSA VA), UR, CSA
Standards CEI EN 61558-2-2 CEI EN 61558-2-2 CEI EN 61558-2-2
CEI EN 61558-2-6 CEI EN 61558-2-6
—
Command and signaling
TM-C, TM-S, TM-I control, isolating and safety transformers
Accidental contact with the secondary winding phases can be withstood without any
danger. Reference standard: CEI EN 61558-2-6
Since TM-C, TM-S and TM-I transformers are not provided with built-in protection, they must
therefore be protected according with these rules:
• Primary: line protection must reach or exceed the recommended value in Chapter 6 of
Electrical installation solutions for buildings - Technical details. This device guarantees line
protection and service continuity but doesn‘t protect the transformer.
• Secondary: transformer protection must be chosen according to tables in the previous
pages. This device protect the transformer.
TM-C
TM-C single phase control transformers, primary 230-400 V
—
Command and signaling
TM-C, TM-S, TM-I control, isolating and safety transformers
TM-S single phase control and safety transformers, primary 230-400 V ±15
6
160 12-24 020738 TM-S 160/12-24 P 2CSM202073R0801 3 1
200 12-24 600435 TM-S 200/12-24 P 2CSM260043R0801 3.2 1
250 12-24 601135 TM-S 250/12-24 P 2CSM260113R0801 3.6 1
320 12-24 600633 TM-S 320/12-24 P 2CSM260063R0801 4.4 1
400 12-24 601036 TM-S 400/12-24 P 2CSM260103R0801 5.5 1
630 12-24 600534 TM-S 630/12-24 P 2CSM260053R0801 7.8 1
1000 12-24 600930 TM-S 1000/12-24 P 2CSM260093R0801 13.2 1
1600 12-24 600831 TM-S 1600/12-24 P 2CSM260083R0801 21.2 1
2000 12-24 600732 TM-S 2000/12-24 P 2CSM260073R0801 25.5 1
2500 12-24 046639 TM-S 2500/12-24 P 2CSM204663R0801 26.8 1
50 24-48 046530 TM-S 50/24-48 P 2CSM204653R0801 1.1 1
100 24-48 046431 TM-S 100/24-48 P 2CSM204643R0801 2 1
160 24-48 046332 TM-S 160/24-48 P 2CSM204633R0801 3 1
250 24-48 046837 TM-S 250/24-48 P 2CSM204683R0801 3.2 1
320 24-48 046738 TM-S 320/24-48 P 2CSM204673R0801 3.6 1
400 24-48 046134 TM-S 400/24-48 P 2CSM204613R0801 4.4 1
630 24-48 046035 TM-S 630/24-48 P 2CSM204603R0801 5.5 1
TM-I single phase control and isolating transformers, primary 230-400 V ±15
Accessories
—
Command and signaling
TS-C safety isolating transformers for general use
TS-C
TS 10 C TS 16 C TS 25 C TS 40 C TS 63 C TS 100 C
Primary rated voltage Un [V] 230 a.c. 230 a.c. 230 a.c. 230 a.c. 230 a.c. 230 a.c.
Secondary rated voltage Un [V] 12 - 24 V 12 - 24 V 12 - 24 V 12 - 24 V 12 - 24 V 12 - 24 V
a.c. a.c. a.c. a.c. a.c. a.c.
Tolerance on secondary voltage [%] < +/- 5% (according to standards)
6
(full load)
TS 25 C Tolerance on secondary voltage [%] <100% rated secondary voltage (according to standards)
(off load)
Rated frequency [Hz] 50/60 50/60 50/60 50/60 50/60 50/60
Rated power (continuous use) [VA] 10 16 25 40 63 100
Maximum output current (at 24 V) [A] 0.42 0.67 1.04 1.67 2.63 4.17
Power loss (off load) [W] < 2.5 <3 <4 < 4.5 < 4.5 <1
Power loss (full load) [W] <5 <5 <5 < 10 < 15 < 20
Modules [No.] 2 3 4 4 5 6
Cable section [mm 2- 2.5
AWG]
Tightening torque [Nm] 0.5
Protection degree IP 20
Standards IEC/EN 61558-2-6
Approvals
TS 100 C
—
Command and signaling
TM bell transformers
Technical characteristics
Primary rated voltage Un [V] 230 a.c.
Secondary rated voltage Un [V] 4, 8, 12, 24
Tolerance on secondary voltage [%] +/- 15% (according to standards)
(with load)
Rated frequency [Hz] 50/60
6
Rated power (discontinuous use) [VA] 10, 15, 30, 40
Power loss (off load) [W] <2.5 (TM10, TM15), <3 (TM30, TM40), <1.25 (TM15 ES)
Modules [No.] 2 (TM10, TM15), 3 (TM30, TM40)
TM 15/12
Cable section [mm2- 2.5 - 14
AWG]
Tightening torque [Nm] 0.5
Protection degree IP 20
Standards IEC/EN 61558-2-8
Approvals
—
Command and signaling
TS bell transformers
Technical characteristics
Primary rated voltage Un [V] 230 a.c.
Secondary rated voltage Un [V] 4, 6, 8, 12, 24
Tolerance on secondary voltage [%] ± 15% (according to standards)
(with load)
Rated frequency [Hz] 50/60
6
—
Command and signaling
RI, BR, TSM, TSR bells and buzzers
Technical characteristics
RI12, BR12 RI230, BR230 TSM, TSR
Rated Voltage Un [V c.a.] 12 230 230
Rated frequency [Hz] 50/60 50/60 50
Power consumption [VA] 4 6 5,5
Sound level Bell [dB] 80 (1)
80 (1)
80(2)
6
Buzzer [dB] 70 (1)
70 (1)
70(2)
Three-tones [dB] 84 (2)
TSM
Max permanent working max 15 sec., after a rest time last 60 sec. TSM: 1 min
time TSR: 5 min
Type of sound signal D D
Duration of operation discontinuous discontinuous discontinuous
Max cable cross-section [mm2] 4 4 10
Mounting position flexible flexible vertical only
Protection degree IP20 IP20 IP20-IP40
Modules (18 mm) [No.] 1 1 2
Standard EN 62080 EN 62080 EN 62080
(1)
at 0.6 meter distance
(2)
at 1 meter distance
RI230
—
Command and signaling
SM, RM, TSM, TSR bells and buzzers
—
Command and signaling
CP-D primary switch mode power supplies
2CDC 271 024 F0b07
Technical features
CP-D CP-D CP-D CP-D CP-D CP-D
12/0.83 12/2.1 24/0.42 24/1.3 24/2.5 24/4.2
Input circuit
Rated input voltage Uin [V AC] 100-240
Input voltage range [V AC] 90-264
6
[V DC] 120-375
Frequency range [Hz] 47-63
CP-D Hold-up time [ms] min. 30 min. 30 min. 30 min. 30 min. 60 min. 60
Internal input fuse, slow-acting [A] 1 2 1 2 2 3.15
(250 V AC)
Typical power at 230 V AC [W] 13 31 12 38 70 114
dissipation
Inrush current limiting (max 3 ms) [A] 30 50 30 50 60 60
Output circuit
Rated output voltage [V DC] 12 12 24 24 24 24
Tolerance of the output ±1%
Adjustment range of the output [V DC] - - - 24-28 24-28 24-28
voltage
Rated output current I r [A] 0.83 2.10 0.42 1.30 2.50 4.20
Rated output power [W] 10 30 10 30 60 100
Resistance to reverse feed [V DC] 18 / 1 s 18 / 1 s 35 / 1 s 35 / 1 s 35 / 1 s 35 / 1 s
Parallel connection Yes, using CP-D RU
Series connection Allowed, to increase voltage
Output circuit: no-load, overload, and short-circuit behaviour
Characteristic curve of output U/I characteristic curve
Short-circuit behavior continuous short-circuit stability
Overload protection output power limiting
No-load protection continuous no-load stability
Currrent limiting at short circuit [A] typ 1.4 typ 5.9 typ 0.78 typ 4.2 typ 6.05 typ 11.5
LED status indicator
Green LED (DC ON) Output voltage applied
Red LED (DC LOW) Output voltage too low
Operating temperature [°C] -40…+70
Derating of the output current 2.5% / °C
60°C < Ta ≤ 70 °C
Approval / Marks cULus, cURus, CCC, EAC, CE, RCM
(depending on device)
6/76 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
CP-D primary switch mode power supplies
• Output voltages 12 V, 24 V
• Adjustable output voltages (devices > 10 W)
• Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A
• Power range 10 W, 25 W, 30 W, 60 W, 100 W
• Wide range input 100-240 V AC (90-264 V AC, 120-375 V DC)
6
Rated input Rated output Bbn Order details Price Weight Pack
voltage voltage/current 1 piece 1 piece unit
CP-D 24/4.2
6/7 7
—
Command and signaling
Modular sockets selection table
Series selection
For further information about sockets selection by country please see in Chapter 6 of Electrical installation solutions for
buildings - Technical details
M1175 M1173 M1170 M1174 M1363 M1011
EU 10A n n n n n
6
Schuko 10 A / 16 A n n n
Italian 10 A n n
Italian 16 A n
British 13 A n
Swiss
n
6/78 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
Modular sockets selection table
Model selection
n RAL 7035
M1175 2CSM210000R0721
M1175-L 2CSM212000R0721
Indicator light
M1175-FL 2CSM214000R0721
Indicator light Fuse 6.3 A aM
M1175-C 2CSM211000R0721
Cover IP30
M1173 2CSM110000R0701
M1173-L 2CSM112000R0701
Indicator light
M1170 2CSM210000R0701
French Standard
—
Command and signaling
Modular sockets selection table
n RAL 7035
British Standard
6
M1363 2CSM259343R0721 2CSM259343R0721
M1363-L 2CSM258163R0721
Indicator light
Single-phase 10 A
M1011-T13 2CSM220685R0721
Type 13
Single-phase 16 A
M1011-T23 2CSM220695R0721
Type 23
Three-phase 10 A
M1011-T15 2CSM220705R0721
Type 15
Three-phase 16 A
M1011-T25 2CSM220715R0721
Type 25
6/80 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
Modular sockets
Technical specifications
Rated voltage Un [V] 250 a.c.
Rated current In [A] 16 (M1170, M1173, M1174, M1175), 13 (M1363),
Rated frequency [Hz] 50/60
Power loss [W] 0,6
Modules [No.] 2.5 for M117x
6
—
Command and signaling
Modular sockets
Modular sockets
Modular sockets allow the connection of devices, tools or electrical and electronic non
modular equipments in civil and industrial electrical switchboards.
The range is composed by standard versions as well as upgraded versions with additional fea-
tures as light indicator, protection fuse and cover.
6
M1175 German Shuko standard modular sockets
M1175-C German Shuko standard modular sockets with integrated indicator light and fuse
M1173
6/82 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
Modular sockets
M1170
French standard modular sockets
M1363
6/83
—
Command and signaling
Modular sockets
6
EAN Type code Order code kg pc.
M1011-T23
M1011-T15
M1011-T25
6/84 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Command and signaling
MA1-8001 DIN rail adapter
Using MA1-8001 it’s possible to put together “System pro M compact” products with LED
pilot light, potentiometer, key selectors, toggle switches, selector switches, push- buttons,
mushroom buttons and emergency stop, illuminated or not.
For detailed description of the industrial devices that can be installed using this kit, see
technical catalogue 1SFC151003C0201
Technical notes
•T o assemble the new housing with push-buttons, selector switch and indicator lamps, contact
blocks and lamp blocks for DIN rails must be used.
• The MCBH-00 holder is not necessary, because the housing hooks directly to contact blocks.
• To line up with “System pro M compact” products, a maximum of 3 blocks must be used.
• In the configuration with 3 contacts, it is advisable to use securing pins to make the blocks
more solid.
• In making up actuators or indicator lamps that use a single contact, one or two MDB-2
empty blocks must be used.
7/1
—
Electrical installation solutions for buildings
Control and automation
Index
DBT Timer digital time switches 7/2
AG Timer electro-mechanical time switches 7/8
E 232 staircase lighting time-delay switches 7/10
CT-D range - Applications 7/12
7
CT-D range - Benefits and advantages 7/13
CT-D range - Operating controls 7/14
CT-D range - Selection table 7/15
E 234 electronic timers 7/16
TL Line twilight switches 7/17
TL1 Pole twilight switches 7/19
E 450 priority switches 7/20
Load management relay 7/21
E 235 mains disconnection relays 7/22
7/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
DBT Timer digital time switches
An ideal range for automating
the functions of the installation
7
Wide range of programs: standard, impulse, cycle, Bluetooth communication combined with the DBT
random and holiday Timer APP available for Android and iOS ensure
• Permanent or temporary manual deviation, smart configuration and quick visualization. This
directly activated with a single touch functionality also allows to transfer programs
7
• LCD Display with back-lighting from one device to another simply using the
• Up to 900 storable events Smartphone.
• Up to 400 pre-defined cities coordinates
• Accuracy of ±0.5 seconds/24h
• Switching solar time/daylight saving time
—
Control and automation
DBT Timer digital time switches
—
Control and automation
DBT Timer digital time switches
7
Max. number of connected devices [No.] 31 31
Max. wiring length [m] 100 100
Terminal size for cable [mm²] 1.5 0.75..1.5
Mounting wall wall
Selection table
Digital time switches DY365 DWA1 DWA1 DW1 DW2 DWTL1
Weekly × n n n n n
Yearly n × × × × ×
Standard function n n n n n n
Astro function n n n × × n
Twilight sensor × × × × × n
Numbers of channels 2 1 2 1 2 1
DY GPS/DY DCF77 n × × × × ×
Bluetooth n n n n n n
2 or 4 channel extension n × × × × ×
Standard function includes: standard, impulse, random cycle and holiday programs.
7/6 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
DBT Timer digital time switches
—
Control and automation
DBT Timer digital time switches
7
DWTL1.
DY365 2CE
DY365 4CE
DWS
7/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
AG Timer electro-mechanical time switches
Technical features
AD1NO- AD1NO- AD1CO- AD1CO- AW1CO- AD1CO- AD1CO- AW1CO-
15m R-15m 30m R-30m R-210m 15m R-15m R-120m
Rated voltage [V] 230 AC
Contact type 1NO 1NO 1NO/NC
Resistive load [A] 16
Inductive load [A] 4
Rated frequency [Hz] 50/60
AD1NO-R-15m Setting step [min] 15 15 30 30 210 15 15 120
(tappet)
Number of tappets 96 96 48 48 48 96 96 84
7
—
Control and automation
AG Timer electro-mechanical time switches
Technical features
AD1-R-15m-72
Rated voltage [V] 230 AC
Contact type 1NO/NC
Ohmic loads [A] 16
7
Running reserve [h] 100
Power loss [W] 1.8
Max. switching power [VA] 4000
Incandescent [W] 3000
Fluorescent (VA) [VA] 1200
Low voltage halogen [VA] 2000
Halogen (230 V ~) [W] 3000
Low consumption lamp (CFL) [VA] 900
LED [VA] 200
Max. terminal cross-section [mm²] 4
Tightening torque [Nm] 0.3
Installation type wall/panel
Protection degree IP20
Operating temperature [°C] -10 …+45
Storage temperature [°C] -20 …+60
Reference standards EN60730-2-7
Selection table
Analog time AD1NO- AD1NO- AD1CO- AD1CO- AW1CO- AD1CO- AD1CO- AW1CO- AD1-
switches 15m R-15m 15m R-15m R-120m 30m R-30m R-210m R-15m-72
Daily n n n n × n n × n
Weekly × × × × n × × n ×
Power reserve × n* × n n × n n n*
Min. time
15 min 15 min 15 min 15 min 120 min 30 min 30 min 210 min 15 min
switching
DIN rail
n n n n n n n n ×
mounting
Panel/wall
× × × × × × × × n
mounting
Type of
NO NO CO CO CO CO CO CO CO
contacts
*non-removable battery
7/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
E 232 staircase lighting time-delay switches
Technical features
E 232-230 E 232E-230N E 232E-8/230N E 232E-230 Multi E 232E-8/230 Multi
10 10
Time range (stepless) 1 – 7 min. 0.5 – 20 min. 0.5 – 20 min. 0.5 – 20 min. 0.5 – 20 min.
in 15 sec. stepless stepless stepless stepless
increments
Control voltage 230 V AC n n n n n
Universal voltage in addition 8 … 240 V AC/DC 8…240 V AC/DC
Glow lamp load 50 mA 150 mA 150 mA 150 mA 150 mA
3/4 conductor operated switches automatically automatically automatically automatically
7
Resettable n n n n n
Steady-light switch n n n n n
Advance warning acc. DIN 18015-2 n n
Long-time range of 60 min. n n
Multi-functional (10 functions) n n
Rated voltage 230 V AC 240 V AC 240 V AC 240 V AC 240 V AC
Rated Frequency 50Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Control voltage range 0.9 ... 1.1 Un 0.85 ... 1.1 Un 0.85 ... 1.1 Un 0.85 ... 1.1 Un 0.85 ... 1.1 Un
Power loss 1 VA 6 VA 6 VA 6 VA 6 VA
Rated switching capacity 16 A, 230 V AC 16 A, 230 V AC 16 A, 230 V AC 16 A, 230 V AC 16 A, 230 V AC
Filament lamps 2,300 W 2,300 W 2,300 W 3,600 W 3,600 W
Halogen lamps 2,300 W 2,300 W 2,300 W 3,600 W 3,600 W
Fluorescent lamps series compensated / 2,300 VA 2,300 VA 2,300 VA 3,600 VA * 3,600 VA *
uncorrected
Fluorescent lamps inductive or capacitive 2,300 VA 2,300 VA 2,300 VA 3,600 VA * 3,600 VA *
Fluorescent lamps shunt compensated 1,300 VA (70 μF) 400 VA (42 μF) 400 VA (42 μF) 1,200 VA (120 μF) * 1,200 VA (120 μF) *
Electronic controlgear 9x7 W, 6x11 W 9x7 W, 7x11 W, 9x7 W, 7x11 W, 34x7 W, 27x11 W, 34x7 W, 27x11 W,
5x15 W, 5x20 W 7x20 W, 7x23 W 7x20 W, 7x23 W 24x15 W, 22x23 W 24x15 W, 22x23 W
Inductive load (cos j = 0.6/230 V AC) 2,300 2,300 2,300 2,300 2,300
Contact material AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2
Contact gap ≥ 3 mm < 3 mm < 3 mm < 3 mm < 3 mm
Mech. serviceable life > 106 > 107 > 107 > 107 > 107
Serviceable life at rated load, cos j =1 > 105 > 2x105 > 2x105 > 2x105 >2x105
Serviceable life at rated load, > 104 > 4x104 > 4x104 > 4x104 > 4x104
cos j =0.6
Max. terminal cross-section 10.7 mm² 13 mm² 13 mm² 13 mm² 13 mm²
Max. conductor cross-section 6 mm² 4 mm² 4 mm² 4 mm² 4 mm²
ON duration Resettable after 100 % 100 % 100 % 100 %
30 sec.
Ambient temperature – 10 °C to + 50 °C – 25 °C to + 50 °C – 25 °C to + 50 °C – 25 °C to + 50 °C – 25 °C to + 50 °C
Housing and insulation material heat resistant, heat resistant, heat resistant, heat resistant, heat resistant,
self-extinguishing self-extinguishing self-extinguishing self-extinguishing self-extinguishing
thermoplast thermoplast thermoplast thermoplast thermoplast
Control current at 230 V AC 4.5 mA 26 mA 26 mA 26 mA (min. 8 mA 26 mA (min. 8 mA
at 8 V AC) at 8 V AC)
Minimum command duration 10 ms 20 ms 20 ms 20 ms / 50 ms for 20 ms / 50 ms for
multi voltage input multi voltage input
—
Control and automation
E 232 staircase lighting time-delay switches
7
range from 0.5 to 20 min, as well as low switching noise make these devices so special.
Devices of the E 232E-230 Multi 10 and E 232E-8/230 Multi 10 series are multi-functional
products with 10 functions to choose from that can be adjusted from the front. Through
an electronically controlled connection of the load at voltage zero, a very high switching
capacity of 3,600 W (load of filament lamp) is reached.
The devices include an integrated warning feature (warning by blinking) according to DIN
18015-2 as well as a 60 minute long-time function.
The E 232E-8/230N and E 232E-8/230 Multi 10 staircase lighting time-delay switches offer
an additional metallically separated control input for 8…240 V AC/DC.
Time range Power loss Bbn Order details Price Weight Pack
4013614 1 1 piece unit
E 232 E-230N
W EAN Type code Order code piece kg pc.
1 … 7 min. 1VA 54824 3 E 232-230 2CDE110000R0501 0.081 10
20 min 6VA 65416 6 E 232 E-230N 2CDE110003R0511 0.095 10
20 min 6VA 65417 3 E 232 E-8/230N 2CDE010003R0511 0.1 10
20 min 6VA 65418 0 E 232 E-230 Multi 10 ˝ 0.095 10
20 min 6VA 65419 7 E 232 E-8/230 Multi 10 2CDE010013R0511 0.1 10
7/12 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
CT-D range
Applications
The CT-D range is designed in a modular housing, making it well suited for building
and residential applications. In just 12 order codes the CT-D range covers all the main
timing functions needed for building automation, safely and reliably.
7
A typical application for timers is Air conditioning systems, heaters and Elevators, escalators, gates,
delayed switching. Switching several fans can be found everywhere in compressors and doors - here too ABB
rows of lamps on and off in corridors, buildings - just like the CT-D timers timers ensure optimum and time-
stairwells, staircases, etc, is a long used to switch them. On-delay, delayed opening as required. ABB ́ s
widespread application in which the off-delay and a range of other CT-D timers cover most functions with
excellent functionality of the CT-D functions cover all requirements. just 12 order codes.
timers is undisputed.
7/13
—
Control and automation
CT-D range
Benefits and advantages
7
The CT-D range is ideal for building applications and installation panels, due to its
compact modular housing. For maximum flexibility in operation, nine single-function
as well as two multifunction devices with seven timing functions are available.
The devices offer four or seven time ranges from 0.05 seconds up to 100 hours.
Their wide supply voltage range allows their use in applications worldwide.
The CT-D range is ideal for installation panels thanks to its compact modular housing. The housing’s
design helps make the status and configuration more clearly visible. The CT-D range also offers
a higher output current than standard industrial types. As well as the 1 c/o contacts, ABB offers
Space savings devices with 2 c/o contacts for maximum flexibility.
Direct reading scales help make time setting quick and easy. A pre-selection for the time range
together with an additional scale for fine adjustments help improve installation efficiency. For more
flexibility, the delay time can even be changed when processes are running, making optimization to
Easy to install fit the application even simpler. All devices can be mounted and demounted tool-free.
The CT-D range fulfills various global standards and approvals, supporting business worldwide.
Additionally, all devices from the CT-D range have a wide supply voltage from 24-48 V DC and
Global availabilty 24-240 V AC, making it ideal for the use in installation panels around the world.
7/14 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
CT-D range
Operating controls
Width 17.5 mm
With a width of just 17.5 mm, the
CT-D range timers are ideally
suited for installation in distribu-
tion panels.
Connection terminals
7
—
Control and automation
CT-D range
Selection table
1SVR500020R0000
1SVR500150R0000
1SVR500100R0000
1SVR500130R0000
1SVR500160R0000
1SVR500110R0000
1SVR500020R1100
1SVR500100R0100
1SVR500160R0100
1SVR500210R0100
1SVR500110R0100
1SVR500211R0100
Order number
CT-VWD.12
CT-MFD.21
CT-MFD.12
CT-AHD.22
CT-AHD.12
CT-SDD.22
CT-TGD.22
CT-ERD.22
CT-SAD.22
CT-EBD.12
CT-TGD.12
CT-ERD.12
7
Type
Timing function
ON-delay A J J J J
OFF-delay with aux. voltage B J J J J
Impulse-ON CA J J J
Impulse-OFF with aux. voltage CB J J
Flasher starting with ON DA J J J
Flasher starting with OFF DB J J
Pulse generator starting
ED
J J
with ON or OFF
Pulse former H J J
Star-delta change-over F J J
Features
Control input, voltage-related triggering J J J J J J
Time range
0.05 s - 100 h J J J J J J J J 2 2
0.05 s - 10 min J J
Supply voltage
12-240 V AC/DC J
24-48 V DC J J J J J J J J J J J
24-240 V AC J J J J J J J J J J J
Output
c/o contact 1 2 1 2 1 2 1 1 1 2
n/o contact 2 2
7/16 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
E 234 electronic timers
Description
The CT-D range with its modular design is a perfect solution for installation panels. For
maximum flexibility in operation, 10 single-function as well as two multifunction devices
with seven timing functions are available. The devices offer four or seven time ranges from
0.05 seconds up to 100 hours. Their wide input range allows their use in applications
worldwide.
E 234 CT-MFD Timing Rated Time Control Output Bbn Type Order code Price Weight
7
0.060
- 1 c/o CT-ERD.12 1SVR500100R0000
(0.132)
ON-delay
0.065
- 2 c/o CT-ERD.22 1SVR500100R0100
(0.143)
E 234 CT-ERD
0.060
n 1 c/o CT-AHD.12 1SVR500110R0000
(0.132)
OFF-delay 7 (0.05 s
- 100 h)
0.065
n 2 c/o CT-AHD.22 1SVR500110R0100
(0.143)
Impulse-
24-240 V AC - CT-VWD.12 1SVR500130R0000
ON
24-48 V DC 0.060
Flasher (0.132)
starting - 1 c/o CT-EBD.12 1SVR500150R0000
with ON
0.060
n CT-TGD.122) 1SVR500160R0000
2×7 (0.132)
Pulse
(0.05 s
generator
- 100 h) 0.065
n 2 c/o CT-TGD.222) 1SVR500160R0100
(0.143)
1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage,
Flasher starting with ON, Flasher starting with OFF, Pulse former
2) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h
3) Transition time 50 ms fixed
4) Transition time adjustable
—
Control and automation
TL Line twilight switches
Technical features
TL1
Rated supply voltage [V] 110 ÷ 230 AC
Contact type 1NO
Incandescent lamps cosj 1 [W] 1000
Fluorescent lamps cosj 0.8 [W] 300
Fluorescent- duo/electronic lamps [W] 300
Rated frequency [Hz] 50/60
TL1 Switching delay ON [s] 23±10%
7
Switching delay OFF [s] 23±10%
Brightness range [lx] 2...200
(with tolerance of +-20%)
Protection degree twilight switch IP20
Protection degree sensor IP54
Operating temperature twilight [°C] -25...+55
switch
Operating temperature sensor [°C] -40...+70
Storage temperature twilight switch [°C] -40...+70
Storage temperature sensor [°C] -50...+80
Power consumption [W] 0.4 W cosj 0.4 (idle)
0.9 W cosj 0.42 (active)
Max terminal cross section [mm²] 6
Terminals loss-proof screw
Screw Type PZ1
Tightening torque terminals [Nm] 1.2
sensor screw [Nm] 1.2
Mounting on DIN rail
Switching status indication/ red/green LEDs
brightness range
Max wiring length [m] 100
Modules [n°] 1
Reference standards EN 60669-1
EN 60662-2-1
EN60730-1
7/18 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Control and automation
TL Line twilight switches
TLs
7/19
—
Control and automation
TL Line twilight switch
Technical features
TL1 POLE
Rated supply voltage [V] 110 ÷ 230 AC
Contact type 1NO polarized
Incandescent lamps cosj 1 [W] 1000
Fluorescent lamps cosj 0.8 [W] 300
Fluorescent- duo/electronic lamps [W] 300
Rated frequency [Hz] 50/60
Switching delay ON [s] 25+-10%
7
Switching delay OFF [s] 35+-10%
TL1 Pole Brightness range [lx] 2...200
(with tolerance of +-20%)
Protection degree twilight switch IP54
Protection degree sensor IP54
Operating temperature twilight [°C] -40...+70
switch
Operating temperature sensor [°C] -40...+70
Storage temperature twilight switch [°C] -50...+80
Storage temperature sensor [°C] -50...+80
Power consumption [W] 0.25 W cosj 0.35 (idle)
0.8 W cosj 0.4 (active)
Max terminal cross section [mm²] 6
Terminals loss-proof screw
Screw Type PZ1
Tightening torque: terminals [Nm] 1.2
screw sensor [Nm] 1.2
Mounting Pole/wall mounted
Switching status indication/ red/green LEDs
brightness range
Max wiring length 100
Modules
Reference standards EN 60669-1
EN 60662-2-1
EN60730-1
—
Control and automation
E 450 priority switches
Technical characteristics
E 451-5.7 E 452-5.7
Operating coil
Range of rated current equivalent to 6.7 … 39 A
correlates
1.5 … 9 kW at 230 V, 4.6 … 27 kW at 230/400 V
Threshold current 3.1 … 5.3 A
OFF delay (max.) 0 main half waves 2 main half waves
Max. continuous current 43 A
E 450
7
—
Control and automation
Load management relay
Technical characteristics
Input
Rated voltage Un [Vac] 230 (-15%/+10%)
Rated frequency [Hz] 50/60
Rated capacity In [A] 32
Power consumption [VA] 4
Display
Type of display backlit LCD
Resolution [kW] 0.01
7
LCR Display dimensions [mm] 27 × 23
Non-priority load
Regulating thresholds [kW] 0.8..7
Resolution of threshold [kW] 0.1
Delay of loads disconnection [sec] 0..9999
Delay between one connection and the next one [sec] 0..9999
Alarm notification LED // buzzer
Relay output
Rated current [A] 16
Rated voltage [Vac] 250
Climatic conditions
Storage temperature -10°C to +65°C
Operating temperature -10°C to +45°C
Relative humidity max. 90% (non-condensing)
Protection degree
At terminals IP20
On the front panel IP51
Max cable cross-section
rigid [mm2] 4
flexible [mm2] 6
Modules (18mm) [No.] 2
—
Control and automation
E 235 mains disconnection relays
Technical features
Short circuit rupturing capacity 16 A/230 AC
Rated frequency 50/60 Hz
Range of control voltage 0.9 to 1.1 Un
Filament lamps 2300 W
Fluorescent lamps:
twin lamp circuit 100 W
shunt compensated 56 W
electronic ballast max. 36 W, dependent on manufacturer
7
E 235
Inductive load cosj 0.6 6A
Max. switching capacity (cosj 0.5) 3500 VA
Intrinsic consumption ca. 1W
Control voltage 5 V a.c.
Adjustable making capacity 2 - 15 VA
Breaking capacity 0.66 x making capacity
ON delay 50 ms
OFF delay ca. 3 sec.
Contact assembly 1 NO contact
Service life at rated load > 100000 switching cycles
Ambient temperature - 10 °C/14 °F to +45 °C/113 °F
Max terminal cross-section 2.5 mm2
7/23
—
Control and automation
E 235 mains disconnection relays
7
E 235-NFS
a capacitor and transformer power pack - e.g. charging stations for rechargeable devices,
standard lamps, etc. - will be reliably detected and switched. Interference fields emitted by
the monitoring voltage are so small that they cannot be registered. The mains is switched on
when the consumer load exceeds the making capacity set in the demand switch. It is cut off
when the consumer load falls to 2/3 of the set making capacity. The ON state is indicated by
the integrated LED. You can choose between „Automatic monitoring“ and „Permanent ON“
using a rotary switch on the E 235.
Accessories
The E 235-GLA base load adapter is also available, and is used for switching the demand
switch on manually. The adapter is plugged into a socket that is monitored by the demand
E 235-GLE switch. The toggle switch switches the base load, which is used to switch on the demand
switch.
Some consumers require an initial voltage equal to the mains voltage in order to be switched
on. These include brightness controllers, and fluorescent and energy-saving lamps. The PTC
base load element E 235-GLE and base load adapter E 235-GLA are available for ensuring reli-
able switch-on of the mains field relay. The indicator light on the adapter displays the
switched on mains voltage, irrespective of the position of the toggle switch. It tells you
whether the mains voltage has been cut off or whether other consumers are still switched
on. If you wish to connect a dimmer to the output of the demand switch, this must feature
an additional switching contact. A base load element is also switched in parallel.
—
Electrical installation solutions for buildings
Energy efficiency
Index
M4M network analyzers 8/2
DMTME multimeters 8/10
CUS 485 TCP/IP converter 8/12
Energy meters selection table 8/16
A-series EQ meters 8/18
B-series EQ meters 8/26
8
C-series EQ meters 8/33
Interfaces for EQ meters 8/37
EQmatic8/38
CMS – Circuit Monitoring System 8/40
CMS – Control Units 8/46
CMS – Sensors and Accessories 8/48
String monitoring CMS-660 8/53
Analogue and digital instruments
selection table 8/56
Modular digital instruments 8/57
Front panel digital instruments 8/59
Analogue instruments selection table 8/60
Modular analogue instruments 8/61
Scales for modular analogue ammeters 8/63
Front-panel analogue instruments 8/64
Scales for front-panel analogue instrument 8/69
Voltmetric and current switches 8/74
E 233 hour counters 8/75
HMT hour counters 8/76
TMD temperature control units 8/77
Current transformers selection table 8/78
CT measurement current transformers
with through primary 8/82
CTA measurement current transformers
with wound primary 8/87
CTO split core measurement
current transformers 8/88
TRF M measurement modular current
transformers8/89
SNT current transformer
for d.c. applications 8/90
8/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
Technical features
Type M4M 20 - Class 0,5S M4M 30 - Class 0,5S
Measurement accuracy*
Measurement type True RMS up to the 40 th harmonic
128 samples per cycle, zero blind
IEC 61557-12 IEC 61557-12 PMD/S/K70/0,5
Class 0,5 acc. to IEC 61557-12 [*]
Active energy
Class 0,5S acc. to IEC 62053-22
Class 2 acc. to IEC 61557-12
Reactive energy
Class 2S acc. to IEC 62053-23
Active power Class 0,5 acc. to IEC 61557-12
Reactive power Class 2 acc. to IEC 61557-12 Class 1 acc. to IEC 61557-12
Apparent power Class 0,5 acc. to IEC 61557-12
Voltage Class 0,2 acc. to IEC 61557-12
Current Class 0,2 acc. to IEC 61557-12
Neutral current Calculated Class 0,2 acc. to IEC 61557-12
Frequency Class 0,1 acc. to IEC 61557-12
Unbalances (Current, Voltage) Class 0,2 acc. to IEC 61557-12
Harmonics, THD (Current, voltage) Class 1 acc. to IEC 61557-12
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
Technical features
8
5 A (Class 0.5S)
CT rated secondary current
1 A (Class 1)
Measurement range without accuracy derating 50 mA - 6 A
Starting current 5 mA
Burden 0.024 VA at 6 A
Indirect insertion with Rogowski coils M4M 20 Rogowski M4M 30 Rogowski
Rated current 10,000 A
Measurement range without accuracy derating 100 A - 12 kA
Starting current [A] 10 A
I/O
Digital Output
Voltage (min - max) 5 - 240 VAC/DC
Current (min - max) 2 - 100 mA
Max ON state drop voltage 1.5 V
Max R value at Min voltage conditions (5 V) 1750 Ohm
Min R value at Max voltage conditions (240 V) 2400 Ohm
Pulse duration [ms] 20 ms ON, 20 ms OFF
Pulse frequency 25 Hz
Alarm activation delay [s] 1 - 900 s (programmable)
Alarm return hysteresis 0 - 40% (programmable)
Digital Input
Maximum voltage 240 VAC/DC
Max voltage for OFF state on input 20 VAC/DC
Min voltage for ON state on input 45 VAC/DC
Analogue Output
Programmable electrical span Span [0 - 20 mA or 4 - 20 mA]
Load Typical 250 Ohm, max 500 Ohm
8/4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
Technical features
Type M4M 20 - Class 0,5S M4M 30 - Class 0,5S
Mechanical characteristics
96 mm × 96 mm × 77 mm
Overall dimensions
(Depth inside the switchboard: 57 mm )
8
Front: IP54
IP degree of protection (acc. to IEC 60529)
Terminals: IP20
Weight [g] 400
Terminal characteristics
Nominal cross section: 2.5 mm2
Solid/stranded wire: 0.2 - 2.5 mm2 (AWG 24 - 12)
Voltage inputs
Pitch: 7.62 mm
Poles: 4
Nominal cross section: 2.5 mm2 Nominal cross section: 2.5 mm2
Solid/stranded wire: 0.2 - 2.5 mm2 Solid/stranded wire: 0.2 - 2.5 mm2
(AWG 24 - 12) (AWG 24 - 12)
Current inputs
Pitch: 5.08 mm Pitch: 5.08 mm
Poles: 6 Poles: 8
Screw flanges for fixing Screw flanges for fixing
Nominal cross section: 2.5 mm2
Solid/stranded wire: 0.2 - 2.5 mm2 (AWG 24 - 12)
RS-485 Serial port
Pitch: 5.08 mm
Poles: 3
Nominal cross section: 2.5 mm2 Nominal cross section: 2.5 mm2
Solid/stranded wire: 0.2 - 2.5 mm2 Solid/stranded wire: 0.2 - 2.5 mm2
(AWG 24 - 12) (AWG 24 - 12)
Pitch: 5.08 mm Pitch: 5.08 mm
I/O Poles: 3 (Programmable I/O, only on M4M Poles: 5 (Programmable I/O)
20 I/O) Poles: 3 (Programmable I/O only on M4M 30
Poles: 3 (Digital outputs) I/O)
Poles: 3 (Analogue outputs, only on M4M Poles: 3 (Analogue outputs, only on M4M 30
20 I/O) I/O)
Only with ABB Rogowski probes:
Rogowski current probes - R4M-200 2CSG202150R1101 (200 mm diameter)
- R4M-80 2CSG202160R1101 (80 mm diameter)
Climatic conditions
Operating temperature -25 to 70 °C (K70 acc. to IEC 61557-12)
Storage temperature -40 to 85 °C (K70 acc. to IEC 61557-12)
Relative humidity Max 93% (non-condensing) at 40°C
Pollution degree 2
Altitude < 2,000 m
User Interface
Access to device 5 pushbuttons Touchscreen
Display type Graphic color display
Display dimensions 70 × 52 mm (3.5")
8/5
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
Technical features
Communication protocol
M4M 20 Modbus, M4M 20 I/O, M4M 20 M4M 30 Modbus, M4M 30 I/O, M4M 30
Modbus RTU
Rogowski Rogowski
8
Communication interface RS485 with optical isolation
Baud rate 9.6, 19.2, 38.4, 57.6, 115.2 kbps
Parity number Odd, Even, None
Stop bit 1, 2
Address 1-247
Connector 3 pole terminal
Profibus DP-V0 M4M 20 Profibus M4M 30 Profibus
Protocol Profibus with slave DP-V0 function in compliance with IEC 61158 regulations
Communication interface RS485 with optical isolation
Baud rate Automatic detection [9.6 kbps - 12 Mbps]
Address 0-126
Connector DB 9 female connector (do not use connectors with 90° cable outlet)
Green for communication status
LED indicators
Red for communication error
Modbus TCP/IP M4M 20 Ethernet M4M 30 Ethernet
Protocol Modbus TCP/IP
Communication interface RJ45 RJ45 (2 ports for daisy-chain)
BACnet M4M 20 Bacnet M4M 30 Bacnet
Protocol BACnet/IP
Communication interface RJ45
Bluetooth
Type BLE (Bluetooth Low Energy)
Real-time clock
Clock drift - ~ 0.4 seconds per day
Battery backup time - ~ 3 days without aux supply
Standards
Power metering and monitoring devices (PMD) IEC 61557-12 (IEC 62053-22, IEC 62053-23)
Electrical safety IEC 61010-1
IEC 61326-1 (IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-
EMC
4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11)
8/6 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
Technical features
Type M4M 20 - Class 0,5S M4M 30 - Class 0,5S
Real-time
TRMS current l l
TRMS Voltage l l
8
Frequency l l
Active, Reactive and Apparent Power l l
Power Factor l l
Operating timer, countdown timer l l
Energy
Active, Reactive and Apparent Energy l l
4 quadrants Energy (Import/Export) l l
Tariffs / l
Power Quality
THD (I, VLN, VLL) l l
Individual Harmonics / 40th
Unbalances (I, VLN, VLL) / l
Neutral current Calculated Measured
Phasors (I, VLN) / l
Waveforms (I, VLN, VLL) / l
Connectivity
Automatic integration in ABB Ability™
EDCS l l
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
M4M 20
M4M 20 is ABB’s network analyzer range that provides complete and accurate electrical
parameters monitoring and basic power quality analysis.
Equipped with graphic color display for advanced visualization of the measured parameters
and Bluetooth module for smart commissioning.
8
BLE, 2 Digital out. 511311 M4M 20 Profibus 2CSG251131R4051 0.400 1
Profibus DP-V0
BLE, BACnet/IP 2 Digital out. 368311 M4M 20 Bacnet 2CSG236831R4051 0.400 1
BLE, Modbus RTU 2 Progr. I/O, 2 511618 M4M 20 I/O 2CSG251161R4051 0.400 1
Digital out., 2
Analogue out.
—
Energy efficiency
Network analyzers – M4M 20 and M4M 30
M4M 30
M4M 30 is ABB’s network analyzer range that allows complete power quality analysis and
energy efficiency evaluations.
Equipped with touchscreen color display for simplified access to the device and with
Bluetooth module for smart commissioning.
—
Notes
8
8/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
DMTME multimeters
1.3 mm
Auxiliary supply [V rms] 230 +15% - 10% DMTME, DMTME-72 and DMTME-96
[V rms] 400 +15% - 10% DMTME-72
[V rms] 115 +15% - 10% DMTME , DMTME-96
Frequency [Hz] 45…65
Power consumption [VA] <6
Fuse protection T0.1A
DMTME Voltage measuring inputs
Range [V rms] From 10 to 500 V AC phase to neutral;
From 17 to 865 V AC phase to phase.
Max. non destructive [V rms] 550
Impedance (L-N) [MW] >8
8
—
Energy efficiency
DMTME multimeters
DMTME multimeters
The instruments DMTME are digital multimeters that allow the measurement, in TRMS mode,
of the principal electrical parameters in three-phase and single-phase 110/230/400 Vac
networks, including the max/min/average detection of the main electrical parameters and
the active and reactive energy count. The multiple measured variables are displayed locally
on four red 7-segment LED displays providing easy readability and simultaneous display of
the measures of the electrical parameters of the phases individually and of the whole
DMTME
network.
The instruments DMTME combine, in a single instrument, the functions of multiple devices:
voltmeter, ammeter, power factor meter, wattmeter, varmeter, frequency meter, active and
reactive energy meters; it allows remarkable financial savings thanks to the reduction of
space taken up in the panel and also of time required for cabling, along with the advantage
of providing clear readings on a single device.
8
The DMTME-I-485, DMTME-I-485-96 and DMTME-I-485-72 models are additionally equipped
with two digital outputs, fully programmable as either pulse outputs for remote metering
of energy consumption, or as alarm outputs. The output relay can be set as NO or NC.
Communication over Modbus RTU protocol is possible through the RS485 serial port. All
versions come complete with Mini CD containing the instruction manual, technical
documentation, Modbus communication protocol and the DMTME-SW tool, intended to be
a first-hand PC-based application for the remote visualization of the measures.
DMTME-96
DMTME modular multimeters
Auxiliary supply 230 V a.c. and 110 V a.c.
—
Energy efficiency
CUS 485 TCP/IP converter
—
Energy meters
The details make the difference
8
Infrared port for
DIN-Rail mounted
communication
and pro M design
between
communications
MID approved
adapter and meter
and verified
—
Energy efficiency
Energy meters. The details make the difference.
Instrumentation
The A series meters support reading of
instrument values. A large number of
electrical properties can be read.
Depending on version of the meter the
following data is available:
• Active power
• Apparent power
• Reactive power
• Current
• Voltage
• Frequency
• Power factor
• Harmonics (Current and Voltage)
• Total harmonic distortion
8/15
—
Energy efficiency
Selection guide EQ meters.
8
Single phase Three phase
Function
C11 B21 A41 A42 C13 B23 B24 A43 A44
Direct connected 1 1 3 1 3 4 1 1 2 3 1 2 3 5
Transformer connected 1 3 5 1 2 3 1 2 3 4 5
2 element metering 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
3 element metering 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Active energy 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Reactive energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Apparent energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Import/Export energy 3 3 4 3 5 2 3 2 3 2 3 5 2 3 4 5
Instrument values 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Alarm function 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
Harmonics, 2th-16th and THD 5 5 5
Pulse output 1 1 1 1 1 1 2 1 2 1 2 1 2
IEC approved 1 1 3 1 3 4 1 3 5 1 1 2 3 1 2 3 1 2 3 5 1 2 3 4 5
—
Energy efficiency
Energy meters selection table
EQ meters C11 EQ meters C13 EQ meters B21 EQ meters B23 EQ meters B24
Overall dimensions 1 DIN module 3 DIN modules 2 DIN modules 4 DIN modules
Frequency 50 / 60 Hz
Max current 40 A 65 A 6A
Reactive energy - -
Optional
Apparent energy - -
Up to 4 tariffs - - Optional
Max/min demand - - - - -
Previous values - - - - -
Load profiles - - - - -
Harmonic analysis - - - - -
Active power
Voltage
Instrumentation parameters (standard)
Current
Power factor
*) The pulse output can be assigned as an output if it is not used for pulses
**) For 16,7 Hz meters
8/17
8
50 / 60 Hz
50 / 60 Hz 50 / 60 Hz
(or 16,7 / 50 / 60 Hz)
80 A 6A 80 A 6A
Standard feature
optional
Cl. 1 (B) Cl. 1 (B), Cl. 0,5 S (C) Cl. 1 (B) Cl.1 (B), Cl. 0,5 S (C)
Optional
Optional
Standard feature
Standard feature
Standard feature
—
Energy efficiency
EQ meters A series
Technical features
A41
Voltage/current inputs
Nominal voltage 230 V AC
Voltage range 57.7 - 288 V AC (-20% - +15%)
3x230/400 V AC
57.7 - 288 or 100 ... 288 V AC (-20% - +15%) 3x57.7/100 ... 288/500 V AC (-20% - +15%) 3x57.7/100 ... 288/500 or
3x100/173 ... 400/690 V AC (-20% - +15%)
1.8 VA (0.8 W) total at 230 V AC
0.001 VA (0.001 W) at Iref and In 0.006 VA (0.006 W) per phase at Iref 0.001 VA (0.001 W) at Iref and In*
- 5A -
1A - 1A
1A 5A 1A
0.05 A 0.5 A 0.05 A
8
6A 80 A 6A
0.02 A 0.25 A 0.01 A
< 1 mA < 20 mA < 1 mA
0.5 - 10 mm2 1 - 25 mm2 0.5 - 10 mm2
1.2 Nm 2 Nm 1.2 Nm
0.5 - 1 mm2
0.25 Nm
-40°C - +70°C
-40°C - +85°C
75% yearly average, 95% on 30 days/year
Terminal 960°C, cover 650°C (IEC 60695-2-1)
IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.
—
Energy efficiency
EQ meters A series
The A series meters ranges from single phase to A series supports following instrumentation val-
three phase meters and from basic up to ad- ues dependent on version of meter:
vanced functionality without any comparison. • Active energy
The A series meters are mounted on a DIN rail and • Current
are suitable for installation in distribution boards • Voltage
and small enclosures such as consumer units. • Power factor
With the main terminals in accordance with DIN • Reactive power
43857 and accessible from the below the meters, • Total harmonic distortion
the A series is suitable for many applications. • Apparent power
• Frequency
The low rated or base currents of these products • Harmonics
ensures high dynamic performance with superior
accuracy even at low currents. The meters sup- A series meters with a functionality level of Gold
8
port a wide voltage range as well as a wide tem- or Platinum have an internal clock for
perature range. The display is pixel-oriented and advanced functionality:
can display up to four quantities at the same • Event log
time. Navigating the meter is easily done via the • Previous values
push-buttons below the display. To configure the • Load profile
meter settings, the set button must be accessed • Maximum and minimum demand
and this
button is protected against unauthorized use The tariffs are controlled via inputs, via
when the “glass lid” on the front of the meter communication or via an internal clock in Gold and
is closed and sealed. The exceptional low power Platinum versions.
consumption of the meters makes them
economical in the long run - an important feature
The A series support up to four I/O’s. It can be
specially for large meter populations.
two inputs and two outputs in a fixed configura-
tion or four I/O points that are freely configured
Data from the A series meters can be collected via
to input or output. Inputs can be used for count-
pulse output or serial communication. The pulse
ing pulses from e.g. a water meter, or reading sta-
output is a solid state relay that generates pulses
tus from external devices. Outputs can be used as
proportionally to the measured energy. The me-
pulse outputs or controlling external apparatus
ters can also be equipped with built-in serial com-
like
munication interfaces for M-Bus or Modbus RTU
a contactor or an alarm (connected via an external
(RS-485). Meters with RS-485 interface can also
relay). The I/O’s need an external voltage supply.
be set to communicate over the new EQ bus with
The A series meters are type approved according
the gateway G13. All meters in the A series come
to IEC and they are both type approved and veri-
with an infrared port for communication with an
fied according to MID. MID is the Measuring In-
external Serial Communication Adapter (SCA)
struments Directive 2014/32/EU from the Euro-
such as the KNX adapter.
pean Commission. MID type approval and
verification is mandatory for meters in billing ap-
plications within EU and EEA. The type approval is
according to standards that covers all relevant
technical aspects of the meter. These include cli-
mate conditions, electromagnetic compatibility
(EMC), electrical requirements, mechanical re-
quirements and accuracy.
8/21
—
Energy efficiency
EQ meters A series
Technical features
A series
Outputs
Type Transistor or MOSFET
Current 2 - 100 mA
Voltage 5 - 240 V AC/DC. For meters with only 1 output, 5 -
40 V DC.
A series Pulse output frequency Programmable: 1 - 999999 imp/kWh
Pulse length Programmable: 10 - 990 ms
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
Inputs
8
Voltage 0 - 240 V AC/DC
OFF 0 - 5 V AC/DC
ON 57 - 240 V AC/24 - 240 V DC
Min. pulse lenght 30 ms
Terminal wire area 0.5 - 1 mm2
Recommended tightening torque 0.25 Nm
EMC compatibility
Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1)
Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5)
Fast transient burn test 4 kV (IEC 61000-4-4)
Immunity to electromagnetic HF-fields 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)
Immunity to conducted disturbance 150 kHz - 80 MHz, (IEC 61000-4-6)
Immunity to disturbance with harmonics 2kHz - 150kHz
Radio frequency emission EN 55022, class B (CISPR22)
Electrostatic discharge 15 kV (IEC 61000-4-2)
Standards EC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-
22 class 0,5 S, IEC 62053-23 class 2, IEC 62054-21,
GB/T 17215.211-2006, GBT 17215.321-2008 class 1
& 2, GB/T 17215.322-2008 class 0,5 S, GB 4208-
2008, EN 50470-1, EN 50470-3 category A, B & C EQ
meters.
Mechanical
Material Polycarbonate in transparent front glass, bottom
case, upper case and terminal cover, Glass
reinforced polycarbonate in terminal block.
Dimensions A41 / A42 A43 / A44
Width 70 mm 123 mm
Height 97 mm 97 mm
Depth 65 mm 65 mm
DIN modules 4 7
8/22 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
EQ meters A series
Direct connected electricity meter up to 80 A. Verified and approved according to MID. IEC
approval.Instrument values. Alarm function. Communication - Infrared (M-Bus).
Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus.
100
57.7...288 V AC, Pulse output, M-Bus 002400 A41 113 - 2CMA100240R1000 0.230 1
100
Class 1 (Reactive Class 2) with functionality level Silver. Active and
reactive energy, import/export, tariffs 1-4, tariff
controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
EQ meters A series
8
100
57.7...288 V AC, Pulse output, M-Bus 002424 A42 113 - 2CMA100242R1000 0.200 1
100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
*) The meters are not tested and approved for placement on rolling stock.
8/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
EQ meters A series
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver. Active and reactive energy,
import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
EQ meters A series
8
3 x 57.7/100...288/500 V AC, 002493 A44 113 - 2CMA100249R1000 0.350 1
Pulse output, M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze. Active and reactive energy, import/export.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
EQ meters B series
Technical features
B21
Voltage/current inputs
Nominal voltage 230 V AC
Voltage range 220...240 VAC (-20% - +15%)
Power dissipation voltage circuits 1.1 VA (0.5 W) total at 230 V AC
Power dissipation current circuits 0.012 VA (0.012 W) at Iref and Ib
B series
Base current I b 5A
Rated current I n -
Reference current I ref 5A
Transitional current I tr 0.5 A
Maximum current I max 65 A
8
B23 B24
3x230/400 V AC
3x220/380...240/415 VAC (-20% - +15%)
1.7 VA (0.8 W) total at 230 V AC
0.007 VA (0.007 W) per phase at Iref and Ib 0.0007 VA (0.0005 W) per phase at Iref and In
-
1A
-
0.05 A
6A
8
0.02 A
< 1 mA
0.5 - 10 mm2
1.2 Nm
1/9 - 9999/1
5000 imp/kWh
IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.
—
Energy efficiency
EQ meters B series
The EQ meters, B series is a range of meters for single phase and three phase metering.
The B series meters are mounted on a DIN rail and are suitable for installation in distribution
boards and small enclosures such as consumer units. The B series are suitable in
applications where there is a need for reliable energy measurements and where space
is limited.
The low rated or base currents of these products ensures high dynamic performance with
superior accuracy even at low currents. The B series meters are meters for many
applications and installations. Navigating the meter is easily done via the push-buttons be-
low the display. To configure the meter settings, the set button must be accessed and this
button is protected against unauthorized use when the “glass lid” on the front of the meter
is closed and sealed. The exceptional low power consumption of the meters, less than 0.9 VA
and 1.6 VA, makes them economical in the long run - an important feature specially for large
8
meter populations.
Data from the B series meters can be collected via pulse output or serial communication. The
pulse output is a solid state relay that generates pulses proportionally to the measured en-
ergy. The meters can also be equipped with built-in serial communication interfaces for M-
Bus or Modbus RTU (RS-485). Meters with RS-485 interface can also be set to
communicate over the new EQ bus with the new gateway G13. All meters in the B series come
with an infrared port for communication with an external Serial Communication
Adapter (SCA) such as the KNX adapter.
The B series meters support reading of instrument values. A large number of electrical
properties can be read. Depending on version of the meter the following data is available:
• Active power
• Apparent power
• Reactive power
• Current
• Voltage
• Frequency
• Power factor
The B series support two inputs and two outputs in a fixed configuration. Inputs can be used
for counting pulses from e.g. a water meter, or reading status from external devices. Out-
puts can be used as pulse outputs or controlling external apparatus like a contactor or an
alarm (connected via an external relay).
The B series meters are type approved according to IEC and they are both type approved and
verified according to MID. MID is the Measuring Instruments Directive 2014/32/EU from the
European Commission. MID type approval and verification is mandatory for meters in billing
applications within EU and EEA. The type approval is according to standards that covers all
relevant technical aspects of the meter. These include climate conditions, electromagnetic
compatibility (EMC), electrical requirements, mechanical requirements and accuracy.
8/29
—
Energy efficiency
EQ meters B series
Technical features
B series
Outputs
Current 2 - 100 mA
8
Inputs
OFF 0 - 5 V AC/DC
EMC compatibility
Impulse voltage test 6 kV 1.2/50μs (IEC 60060-1)
Standards IEC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-22 class
0,5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T 17215.211-
2006, GB/T 17215.312-2008 class 1 & 2, GB/T 17215.322-
2008 class 0,5 S, GB 4208-2008, EN 50470-1, EN 50470-3
category A, B & C
Mechanical
Width 35 mm 70 mm
Height 97 mm 97 mm
Depth 65 mm 65 mm
DIN modules 2 4
8/30 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
EQ meters B series
1 x 230 V AC, Pulse output, M-Bus 001519 B21 113 - 100 2CMA100151R1000 0.150 1
For direct connection up to 65 A. Class B (Cl. 1) (Reactive Cl. 2) with functionality level Silver.
Active and reactive energy, import/export, tariffs 1-4, tariff controll via inputs and communication.
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
EQ meters B series
8
100
3 x 230/400 V AC, Pulse output, 001649 B23 112 - 2CMA100164R1000 0.320 1
RS-485 100
3 x 230/400 V AC, Pulse output, 001656 B23 113 - 2CMA100165R1000 0.330 1
M-Bus 100
Class B (Cl. 1) (Reactive Cl. 2) with functionality level Bronze.
Active and reactive energy, import/export.
—
Energy efficiency
EQ meters B series
—
Energy efficiency
EQ meters C series
The EQ meters, C series are truly compact meters for single phase and three phase
metering. The C series is mounted on a DIN rail and is suitable for installation in distribution
boards and small consumer units.
Only one or three module wide, the C series is a very compact meter for single phase
and three phase applications. The meters have an LCD with large digits showing energy
register and instrumentation values. The meters have a wide temperature range which
makes it possible to install the meters in many locations. Navigating the meters are easily
done via the push-button below the display. The exceptional low power consumption of the
meters, less than 0,3 W and 0,6 W at 230 V AC, makes them economical in the long run
- an important feature specially for large meter populations.
The C series meters support reading of instrument values. A number of electrical properties
8
can be read:
• Power factor
• Active power
• Current
• Voltage
The C series meters have an output that can be used as pulse output or alarm output.
The alarm quantity and levels is easily configured on the meter with the push button.
The output can be used for controlling external apparatus like a contactor or an alarm
indicator (connected via an external relay).
The C series meters are type approved according to IEC and MID. MID is the Measuring
Instruments Directive 2014/32/EU from the European Commission. The type
approval is according to standards that covers all relevant technical aspects of the meter.
These include climate conditions, electromagnetic compatibility (EMC), electrical
requirements, mechanical requirements and accuracy.
MID versions have initial verification according to annex F of the Measuring Instruments
Directive.
8/34 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
EQ meters C series
Technical features
C11 C13
Voltage/current inputs
Nominal voltage 230 V AC 3x230/400 V AC
Voltage range 230 V AC (-20% - +15%) 3x230/400 V AC (-20% - +15%)
Power dissipation voltage circuits 7.4 VA (0.3 W) at 230 V 1.5 VA (0.6 W) total at 230 V
Power dissipation current circuits 0.04 VA (0.04 W) at Ib and Iref 0.04 VA (0.04 W) per phase at Ib
C series
and Iref
Base current I b 5A
Rated current I n -
Reference current I ref 5A
Transitional current I tr 0.5 A
8
—
Energy efficiency
EQ meters C series
Technical features
C11 C13
Outputs
Type Transistor
Current 2 - 100 mA
Voltage 5 - 40 V DC
Pulse output frequency 100 or 1000 (imp/kWh)
Pulse length 100 ms
Terminal wire area 0.5 - 10 mm2 0.5 - 6 mm2
Recommended tightening torque 0.8 Nm 0.25 Nm
EMC compatibility
Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1)
8
Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5)
Fast transient burn test 4 kV (IEC 61000-4-4)
Immunity to electromagneti 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)
HF-fields
Immunity to conducted 150 kHz - 80 MHz, (IEC 61000-4-6)
disturbance
Immunity to disturbance with 2kHz - 150kHz
harmonics
Radio frequency emission EN 55022, class B (CISPR22)
Electrostatic discharge 15 kV (IEC 61000-4-2)
Standards IEC 62052-11, IEC 62053-21 class 1, GB/T 17215.211-2006, GBT
17215.321-2008 class 1, GB 4208-2008, EN 50470-1, EN 50470-3
category B
Mechanical
Material Glass reinforced polycarbonate
Dimensions
Width 17,5 mm 54 mm
Height 111 mm 122 mm
Depth 65 mm 65 mm
DIN modules 1 3
8/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
EQ meters C series
For direct connection up to 40 A. Class B (Cl.1) with functionality level Steel. Active energy
C13
Description Bbn Order details Price Weight Pack
7392696 1 piece 1 piece unit
—
Energy efficiency
Interfaces for EQ meters
8
8/38 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
EQmatic
—
Notes
8
8/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
CMS – Circuit Monitoring System overview
The quality of a Circuit Monitoring System is de- ness, technology, measurement results, user
pendent on the strengths of the individual com- friendliness and flexibility - every component
ponents and how well they interact. ABB’s new and every feature of the CMS has been fully opti-
CMS sets new and high standards. Compact- mized in terms of practicality and functionality.
8
Example illustration:
Control Unit CMS-700 in
combination with CMS
open-core sensors
CMS-600
CMS-700
Control Units
The control unit evaluates the measurement data
picked up by the sensors, and makes it available via
CMS-660 the provided interfaces.
Connection technology
Connecting the sensors to the Control Unit is
extremely simple and requires no special tools.
All sensors are connected to the Control Unit by
means of a flexible flat cable and insulation
displacement connectors. The positioning of
sensors is fully customizable so that they sit
8
exactly where a measurement is required.
Sensors
CMS sensors can be placed anywhere in
the system, without any limitation. Easy
initializing is guaranteed by the unique
ID assigned to each sensors via Control
Unit in just a few simple steps.
All measurement functions are available
right after commissioning.
Serial interfaces
Depending on the selected control unit,
the following communication interfaces are
available: RS485 (Modbus RTU), LAN (TCP/IP
and Modbus TCP), SNMP v1/v2 and v3 encrypted.
—
Energy efficiency
Circuit Monitoring System
—
Energy efficiency
Circuit Monitoring System
8
Early warning system (predictive maintenance) Cost analysis to reduce and assign energy costs
for increasing the availability of critical consumers The cost of energy will rise continuously. In order to cut
Continuous monitoring of the current flow at the circuit costs, you first have to know where they arise. The Control
breaker makes it possible to detect overloaded lines before Unit helps illustrate and analyze the instantaneous energy
they lead to a service interruption. Apart from this, monitor- consumption levels. Furthermore, the calculated active en-
ing individual circuits indicates whether the loads are in the ergy can be used to roughly allocate the costs at the output
desired operating mode or not. In this way, system devia- level.
tions can be ascertained instantaneously. What’s more, the
CMS can be used to detect unbalanced loads before they re-
sult in failure of the neutral conductor and consequently
load failure.
8/4 4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Circuit Monitoring System
Sensors overview
Mounting method for all MCBs, RCDs, for MCBs for fuse for all S800 devices with universally universally
RCBOs with (S200, SMISSLINE) and RCBOs holders E90 cage terminals usable usable
twin terminals (SMISSLINE)
8
Open-core sensors
AC accuracy* of ≤ ± 1.0%
Solid-core sensors
AC accuracy* of ≤ ± 0.5%
* All accuracy specifications refer to the relevant full scale value and apply to 25°C
8/45
—
Energy efficiency
Circuit Monitoring System
Control units
Characteristics Control Unit CMS-700 Control Unit CMS-600
CMS Sensors
Sensors 96 (3x32) 64 (2x32)
Control Unit
8
Integrated power supply •
Voltage measurement •
Current (External CTs are required) measurement •
Active, reactive and appearent power (External CTs are required) measurement •
Calculated values for the branches
Energy (Using branch currents, mains voltage and power factor over time) •
Power (Using branch currents, mains voltage and power factor) •
Interfaces
RS485 • •
LAN •
Protocols
Modbus RTU • •
Modbus TCP •
SNMP (v1, v2 and encrypted v3) •
Visualization
Built-in web server •
Touch display •
CSV data export •
Approvals
IEC 61010-1 • •
UL 508 / CSA C22.2 No. 14 • •
8/46 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Control units
—
Energy efficiency
Control units
CMS-700 CMS-700
The CMS-700 measures the AC and DC currents in the outgoing circuits via up to 3 x 32
sensors and calculates the energy and output data (line-side active and reactive power)
of up to 96 sensors simultaneously.
8
The Control Unit CMS-700 has been developed specifically to meet the requirements
of critical power applications, such as tho¬se of computing centers. In addition, however,
professional energy monitoring is becoming ever more important when it comes to
identifying savings potentials in functional buildings such as office buildings.
CMS-600
CMS-600
The CMS-600 system enables you to measure AC and DC currents in up to 64 branches.
For simple and fast operation, the Control Unit is equipped with an illuminated touch
display that makes not only initialization but also control of the sensors extremely simple.
A 2-wire RS485 Modbus RTU interface enables users to remotely query and process
the measurement data. As such, the CMS-600 Control Unit can be very easily integrated
into an existing Modbus architecture. As an option, the measured values can also be
visualized and processed by me¬ans of a programmable logic control (PLC).
CMS-600 is equipped with an integrated CMS software for which great care has been
CMS-600 taken to ensure that the navigation concept is highly intuitive
User Manual
The Control Unit CMS-600 are put to use in the critical power systems of hospitals
and in similar industrial applica¬tions, too. Furthermore, these devices can also be
found in functio¬nal buildings such as airports, hotels, office buildings, universities/
colleges and museums or in industrial photovoltaics.
Control units
Control Unit CMS-700 453138 CMS-700 2CCA880700R0001 0.329 1
Control Unit CMS-600 418700 CMS-600 2CCA880000R0001 0.153 1
8/48 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Sensors and Accessories
* All accuracy specifications refer to full scale value and apply at 25° C.
In the case of open-core sensors, the position of the cable affects accuracy.
CMS-120CA
Solid-core sensors 18 mm
* All accuracy specifications refer to the relevant full scale value and apply at 25° C.
CMS-120CA
8/49
Solid-core sensors 25 mm
8
Respond time (±1 %) [sec] Type 0.25
Max. diameter of the cable [mm] 15
Insulation [V] 690 V AC /1500 V DC
Operating temperature [°C] − 25 ... +70 / − 40 ... + 85
Size CMS-200S8 series [mm] 26.5 x 43.0 x 38.5
CMS-200DR series [mm] 25.4 x 43.0 x 43.2
CMS-120CA
CMS-200CA series [mm] 25.4 x 43.0 x 35.7
Reference standard IEC 61010-1 | UL508 / CSA C22.2 No 14
* All accuracy specifications refer to the relevant full scale value and apply at 25 °C.
8/50 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Sensors and Accessories
—
Energy efficiency
Sensors and Accessories
Open-core sensors
Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
Open-core sensors 18 mm for retrofit of MCBs (S200, SMISSLINE) and RCBOs (SMISSLINE)
80 A CMS-120LA 2CCA880225R0001 0.012 1
40 A CMS-121LA 2CCA880226R0001 0.012 1
20 A CMS-122LA 2CCA880227R0001 0.012 1
8
Open-core sensors 18 mm for pro M and SMISSLINE devices with twin terminals
80 A CMS-120PS 2CCA880210R0001 0.012 1
40 A CMS-121PS 2CCA880211R0001 0.012 1
20 A CMS-122PS 2CCA880212R0001 0.012 1
Solid-core sensors
Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
Solid-core sensors 18 mm for pro M & SMISSLINE installation devices with twin terminals
80 A CMS-100PS 2CCA880100R0001 0.012 1
40 A CMS-101PS 2CCA880101R0001 0.012 1
20 A CMS-102PS 2CCA880102R0001 0.012 1
—
Energy efficiency
Sensors and Accessories
Solid-core sensors
Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
Control Unit
Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
CMS-600 Control Unit CMS-600 2CCA880000R0001 0.153 1
CMS-700 Control Unit CMS-700 2CCA880700R0001 0.329 1
Accessories
Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
2 m flat cable CMS-800 2CCA880148R0001 0.017 1
5 m flat cable CMS-802 2CCA880331R0001 0.045 1
10 m Flat cable CMS-803 2CCA880332R0001 0.090 1
30 m Flat cable CMS-805 2CCA880333R0001 0.270 1
Connector set (35 pcs) CMS-820 2CCA880145R0001 0.024 35
8/53
—
String monitoring
CMS-660 circuit monitoring system
8
integration to different system con- high temperature), facilitating main-
ditions tenance of the system
User friendliness
Local information, thanks to
the LEDs, about network and
device status. Reset button to
easily set the device.
Smart commissioning
Thanks to the intelligent, intuitive
Compatibility configuration, the CMS system can be
RS485 port to guarantee easy configured and put into operation in
integration with the plant / in- just a few minutes.
verter monitoring systems.
—
Energy efficiency
String monitoring CMS-660
Control Unit
—
Notes
8
8/56 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Analogue and digital instruments selection table
VLM
3 modules Direct MCV voltage switches
page 8/45
Analogue a.c.
72x72, VLM-1
Direct MCV voltage switches
96x96 page 8/50
Voltage
VLMD
3 modules Direct MCV voltage switches
page 8/42
a.c. and d.c.
8
AMT
Direct MCA current switches
page 8/45
3 modules
CT a.c. current transformer
AMT1/A
SNT shunt for d.c.
Indirect AMT2
SCL interchangeable scale
page 8/46
MCA current switches
Analogue a.c. and d.c.
AMT1-A1
Direct MCA current switches AMT2-A2
page 8/52
72x72,
Current
96x96
CT a.c. current transformer AMT1-A1
SNT shunt for d.c. AMT1-A5
Indirect
SCL interchangeable scale AMT2-A2
MCA current switches page 8/52
72x72, FRZ
Frequency Analogue Direct a.c.
96x96 page 8/54
8/57
—
Energy efficiency
Modular digital instruments
Technical features
Power supply [V] 230 V a.c.
Rated frequency [Hz] 50÷60
Ammeter full scale value [A] 5, 20, 25, 40, 60, 100, 150, 200, 250, 400, 600, 999
Voltmeter full scale value [V] 600
Frequency meter range [Hz] 35...400
Tripping delay [s] 1, 5, 10, 20, 30
Hysteresis [%] 5, 10, 20, 30 set threshold
Digital instruments
Output pins 3-4
Output relay NO
Rated voltage relay [V] 230 V a.c.
Rated current relay [A] AC1 16, AC15 3
8
Relay configuration NO relay closes in alarm status
NC relay opens in alarm status, positive safety
Overload [In/Vn] 1, 2
Accuracy class [%] ±0,5 full scale ±1digit at 25 °C
Max. signal input value for 5 A a.c./60 mV d.c.
ammeters
Display 3 digit LED display
Operating temperature [°C] -10…+55
Storage temperature [°C] -40...+70
Protection degree IP20
Power consumption [VA] 4
Modules 3
Overall dimensions front panel [mm] 36x72x61.5 (51.5 depth inside the switchboard)
devices
Standard IEC EN 61010
8/58 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Modular digital instruments
FRZ
8/59
—
Energy efficiency
Front panel digital instruments
8
a.c. digital ammeter 136156 AMTD-1 P 2CSG213615R4011 0,300 1
—
Energy efficiency
Analogue instruments selection table
72x72 mm
a.c.
8
96x96 mm
—
Energy efficiency
Modular analogue instruments
Technical features
Rated voltage Un [V] a.c. 300, 500; d.c. 100, 300
Rated currents in Direct reading [A] full scale values 5...30
a.c. Indirect reading full scale values 5...2500
Rated currents in Direct reading [A] full scale values 0.1...30
d.c. Indirect reading full scale values 5...500
Frequency [Hz] 50/60
Overload capacity [%] 20 compared to the voltage or to the rated current
VLM1
Accuracy class [%] 1.5 (0.5 for frequency meters)
Ammeters power consumption [VA] 5 A: 0.3 VA; 10 A: 0.6 VA; 25 A:1 VA; 30 A: 1.2 VA
Voltmeters power consumption [VA] 300 V: 1.5 VA; 500 V: 4 VA
Frequency meters power [VA] <1.5 VA
8
consumption
Modules [No.] 3
Protection degree IP20
Standards EN 60051
—
Energy efficiency
Modular analogue instruments
VLM2
Ammeters: direct connection
8
AMT2
8/63
—
Energy efficiency
Scales for modular analogue ammeters
8
A1-50A 001607 SCL 1/50 2CSM110149R1041 0.010 10
A1-60A 030904 SCL 1/60 2CSM110159R1041 0.010 10
A1-75A 031000 SCL 1/75 2CSM110169R1041 0.010 10
A1-80A 001706 SCL 1/80 2CSM110179R1041 0.010 10
A1-100A 001805 SCL 1/100 2CSM110189R1041 0.010 10
A1-150A 001904 SCL 1/150 2CSM110209R1041 0.010 10
A1-200A 002000 SCL 1/200 2CSM110229R1041 0.010 10
A1-250A 031109 SCL 1/250 2CSM110249R1041 0.010 10
A1-300A 002109 SCL 1/300 2CSM110259R1041 0.010 10
A1-400A 002208 SCL 1/400 2CSM110279R1041 0.010 10
A1-500A 002307 SCL 1/500 2CSM110299R1041 0.010 10
A1-600A 031208 SCL 1/600 2CSM110309R1041 0.010 10
A1-800A 002406 SCL 1/800 2CSM110329R1041 0.010 10
A1-1000A 002505 SCL 1/1000 2CSM110339R1041 0.010 10
A1-1500A 274704 SCL 1/1500 2CSM110359R1041 0.010 10
A1-2000A 274803 SCL 1/2000 2CSM110379R1041 0.010 10
A1-2500A 274902 SCL 1/2500 2CSM110389R1041 0.010 10
8/64 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Front-panel analogue instruments
Technical features
Rated max. reference voltage for [V] 600 (a.c meters), 300 (d.c. meters)
insulation
Test voltage [V] 2000 eff. (50 Hz/1 min)
Accuracy class 1.5 (0.5 for frequency meters)
Overload capacity a
- ammetric windings up to In x 10/< sec. up to In x 2/permanent
- voltmetric windings up to Un x 2/< 5 sec. up to Un x 1.2/permanent
Front panel analogue instruments
Operating temperature [°C] -10...+55
Storage temperature [°C] -40...+70
Average and max. relative 65% (yearly average)
humidity (DIN 40040) b 85% (+35 °C/60 days a year)
8
Vibration resistance (IEC 50-1) [g (9.81 m/s)] 0.08-1.8 (0.35 mm/10-55 Hz; 3 axis/6 h)
Degree of protection IP52 indoors
IP00 on the terminals (IEC 144. DIN 40050)
IP20 with suitable terminal covers
Materials
- cases and front edge self-extinguishing thermosetting material
in accordance with UL94 V-0, fungus and termite
resistant
- pointers (DIN 43802) c molded aluminium
- terminals brass
Assembly vertical/horizontal with special screw-on brackets d
Dimensions W x H x D [mm] 48 x 48 X 53 72 x 72 x 53 96 x 96 X 53
(DIN 43700/43718)
Applicable standards IEC EN 61010-1
a The overload can be greater for instruments enabled by a CT because the transformer generally keeps secondary current
peaks to within 10 In.
b Tropicalization enables the instruments to withstand up to 95% max. relative humidity (+35 °C/60 days). In accordance
with DIN standard 40040, they must be protected against any penetration of humidity inside the device. Terminals,
screws, washers, bolts and magnets are galvanically protected against rust, while the electrical circuits are painted with
the special Multicolor PC52 varnish.
c The pointer damping time is 1 second. The recorded values are cleared by pressing the control provided.
d With 0.5 mm -19 mm thick panels, the screws must be attached in the fixing position nearest to the front edge of the
measuring device, whereas the 20 mm - 39 mm thick panels require the screws to be fixed in the position furthest away
from the front edge.
8/65
—
Energy efficiency
Front-panel analogue instruments
Available in both alternating current and direct current versions, the front-panel mono-
function measurement devices come in two standard sizes, 72 mm x 72 mm and
96 mm x 96 mm (special versions available on request), employable in single-phase
networks. The range is composed ammeters for a.c. and d.c. applications, and voltmeters
and frequency meters for a.c. applications. Ammeters without scale for indirect connection
must be completed with the appropriate scale, chosen according to the full-scale value.
8
72 D 60 544203 VLM-1-60/72 2CSG112110R4001 1
72 D 80 544302 VLM-1-80/72 2CSG112120R4001 1
72 D 100 544401 VLM-1-100/72 2CSG112130R4001 1
72 D 150 544500 VLM-1-150/72 2CSG112150R4001 1
72 D 200 544609 VLM-1-200/72 2CSG112160R4001 1
72 D 250 544708 VLM-1-250/72 2CSG112180R4001 1
72 D 300 544807 VLM-1-300/72 2CSG112190R4001 1
72 D 400 544906 VLM-1-400/72 2CSG112210R4001 1
72 D 500 545002 VLM-1-500/72 2CSG112220R4001 1
72 D 600 545101 VLM-1-600/72 2CSG112230R4001 1
8/66 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Front-panel analogue instruments
Size Inser- Scale VT type Bbn Order details Price Weight Pack
tion 8012542 1 1 piece unit
piece
mm V a.c. EAN Type code Order code kg pc
96 D 50 546702 VLM-1-50/96 2CSG113100R4001 1
96 D 60 546801 VLM-1-60/96 2CSG113110R4001 1
96 D 80 546900 VLM-1-80/96 2CSG113120R4001 1
96 D 100 547006 VLM-1-100/96 2CSG113130R4001 1
VLM 96 D 150 547105 VLM-1-150/96 2CSG113150R4001 1
96 D 200 547204 VLM-1-200/96 2CSG113160R4001 1
96 D 250 547303 VLM-1-250/96 2CSG113180R4001 1
96 D 300 547402 VLM-1-300/96 2CSG113190R4001 1
96 D 400 547501 VLM-1-400/96 2CSG113210R4001 1
8
D: direct connection
8/67
—
Energy efficiency
Front-panel analogue ammeters for alternating current
8
72 D 60 546405 AMT1-A1-60/72 2CSG312110R4001 1
72 I SCL-A1 546504 AMT1-A1/72 2CSG322250R4001 1
72 I SCL-A5 546603 AMT1-A5/72 2CSG322260R4001 1
D: direct connection
I: indirect connection with VT, CT and shunt, according to the type
8/68 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Front-panel analogue instruments
D: direct connection
I: indirect connection with VT, CT and shunt, according to the type
8/69
—
Energy efficiency
Scales for front-panel analogue instrument
8
50 772408 SCL-A1-50/72 2CSG112149R5011 0.010 10
60 772507 SCL-A1-60/72 2CSG112159R5011 0.010 10
80 772606 SCL-A1-80/72 2CSG112179R5011 0.010 10
100 572305 SCL-A1-100/72 2CSG112189R5011 0.010 10
150 572404 SCL-A1-150/72 2CSG112209R5011 0.010 10
200 572503 SCL-A1-200/72 2CSG112229R5011 0.010 10
250 572602 SCL-A1-250/72 2CSG112249R5011 0.010 10
300 572701 SCL-A1-300/72 2CSG112259R5011 0.010 10
400 572800 SCL-A1-400/72 2CSG112279R5011 0.010 10
500 572909 SCL-A1-500/72 2CSG112299R5011 0.010 10
600 573005 SCL-A1-600/72 2CSG112309R5011 0.010 10
800 573104 SCL-A1-800/72 2CSG112329R5011 0.010 10
1000 573203 SCL-A1-1000/72 2CSG112339R5011 0.010 10
1500 573302 SCL-A1-1500/72 2CSG112359R5011 0.010 10
2000 573401 SCL-A1-2000/72 2CSG112379R5011 0.010 10
2500 573500 SCL-A1-2500/72 2CSG112389R5011 0.010 10
3000 573609 SCL-A1-3000/72 2CSG112399R5011 0.010 10
4000 573708 SCL-A1-4000/72 2CSG112409R5011 0.010 10
5000 573807 SCL-A1-5000/72 2CSG112419R5011 0.010 10
6000 573906 SCL-A1-6000/72 2CSG112429R5011 0.010 10
8000 574002 SCL-A1-8000/72 2CSG112439R5011 0.010 10
10000 574101 SCL-A1-10000/72 2CSG112449R5011 0.010 10
8/70 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Scales for front-panel analogue instrument
—
Energy efficiency
Scales for front-panel analogue instrument
8
50 774600 SCL-A1-50/96 2CSG113149R5011 0.010 10
60 774709 SCL-A1-60/96 2CSG113159R5011 0.010 10
80 774808 SCL-A1-80/96 2CSG113179R5011 0.010 10
100 584100 SCL-A1-100/96 2CSG113189R5011 0.010 10
150 584209 SCL-A1-150/96 2CSG113209R5011 0.010 10
200 584308 SCL-A1-200/96 2CSG113229R5011 0.010 10
250 584407 SCL-A1-250/96 2CSG113249R5011 0.010 10
300 584506 SCL-A1-300/96 2CSG113259R5011 0.010 10
400 584605 SCL-A1-400/96 2CSG113279R5011 0.010 10
500 584704 SCL-A1-500/96 2CSG113299R5011 0.010 10
600 584803 SCL-A1-600/96 2CSG113309R5011 0.010 10
800 584902 SCL-A1-800/96 2CSG113329R5011 0.010 10
1000 585008 SCL-A1-1000/96 2CSG113339R5011 0.010 10
1500 585107 SCL-A1-1500/96 2CSG113359R5011 0.010 10
2000 585206 SCL-A1-2000/96 2CSG113379R5011 0.010 10
2500 585305 SCL-A1-2500/96 2CSG113389R5011 0.010 10
3000 585404 SCL-A1-3000/96 2CSG113399R5011 0.010 10
4000 585503 SCL-A1-4000/96 2CSG113409R5011 0.010 10
5000 585602 SCL-A1-5000/96 2CSG113419R5011 0.010 10
6000 585701 SCL-A1-6000/96 2CSG113429R5011 0.010 10
8000 585800 SCL-A1-8000/96 2CSG113439R5011 0.010 10
10000 585909 SCL-A1-10000/96 2CSG113449R5011 0.010 10
8/72 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Scales for front-panel analogue instrument
—
Energy efficiency
Scales for front-panel analogue instrument
8
600 598909 SCL-A2-600/96 2CSG233309R5011 0.010 10
800 599005 SCL-A2-800/96 2CSG233329R5011 0.010 10
1000 599104 SCL-A2-1000/96 2CSG233339R5011 0.010 10
8/74 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Voltmetric and current switches
Technical features
Insulation voltage [V] 600
Rated thermal current [A] 12
Mechanic operations [No.] 1000000
Power consumption [VA] 0.23
Modules [No.] 3
MCV
Voltmeter switches
Range Power loss Bbn Order details Price Weight Pack
7392696 1 1 piece unit
piece
W EAN Type code Order code kg pc.
L1, L2, L3 0.5 52246 9 MCV 4 1SCA022404R4740 0.095 1
MCA
L1, L2, L3, N 0.5 52243 8 MCV 7 1SCA022647R7840 0.110 1
Current switches
Range Power loss Bbn Order details Price Weight Pack
7392696 1 1 piece unit
piece
W EAN Type code Order code kg pc.
0-1-2-3 0.5 52245 2 MCA 4 1SCA022404R4821 0.110 1
QCV 48
8/75
—
Energy efficiency
E 233 hour counters
Technical features
AC equipment DC equipment
Rated voltage 50 Hz: 24 V, 230 V DC 12 V ... 48 V
60 Hz: 24 V, 120 V, 240 V
Voltage tolerance ±15 % ±10 %
Power consumption 1.5 VA ca. 20 mW (at 12 V DC)
Ambient temperature –15 °C/5 °F... +50 °C/122 °F –10 °C/14 °F ... +50 °C/122 °F
Counting capacity 99.999 h 99.999 h
Reading accuracy 0.01 h 0.1 h
E 233
Operation display fast running LED blinking
Protection against electric shock according to DIN VDE 0106 according to DIN VDE 0106
Part 100 (BGV A2) Part 100 (BGV A2)
8
Terminal size up to 10 mm2 up to 10 mm2
—
Energy efficiency
HMT hour counters
Technical features
Rated voltage Un [V] a.c. 24
a.c. 110
a.c. 230
Displayed digits (in hours) [n°] 99,999.9 (for HMT1 and HMT11)
Accuracy class [%] 0.5
Frequency [Hz] 50
Power consumption [W] 1.1...2.2
—
Energy efficiency
TMD temperature control units
Technical features
Auxiliary supply Alternating current [V] 20÷250 ±15%
Direct current [Hz] 115-230-400 50-60
Power consumption [VA] 4 max
Input Sensor PT100 RTD (not included)
Type 3 wires (2 and 4 wires types are also supported)
TMD Error 1 degree every 0,39 W
Measure range [°C] 0...220 ± 2
Compensation [W] 20 max
Trip delay/hysteresis [s/°C] 5/2
Output Number 4
Type NO-CO-NC
8
Vmax [V] 12 d.c.
Imaxww [A] 8 (resistive load)
Functions Alarm, trip, cooling, auto-test
Programmable Alarm, tip, hold, fan, temp. max
functions
Display 7 segments LED
Connections Terminals removable screw
Max section [mm2] 2.5
Insulation voltage [V] 2500/50 Hz - 1 min
Protection degree Front IP52
Rear IP20
Operation temperature [°C] -10...+55, relative humidity max 90%
Storage temperature [°C] -25...+80
Reference IEC EN 50081-2, IEC EN 50082-2, IEC EN 60255
—
Energy efficiency
Current transformers selection table
Breaker choice
Modular S200, S280, S290, S700, S750DR, S800
Tmax XT1, XT2, XT3, XT4, T4320 T5
Emax
Installation choice
Fixing DIN rail DIN rail DIN rail, cable or bus bar Bus bar DIN rail, cable or bus bar,
system base mounted with feet
8
T6,T7 T6,T7
E1.2, E2.2, E4.2 E2, E3, E4, E6 E2.2, E4.2, E6.2 E2.2, E4.2 E1.2
Cable or bus bar, Bus bar Cable or bus bar, Bus bar
base mounted with feet base mounted with feet
8
CT6 CT8 CT8V CT80 CT12 CT12V CT120 Class
0,5
0,5
0,5
0,5
2CSG421140R1101 0,5
CT6/300
8/80 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
Current transformers selection table
Breaker choice
Modular S200, S280, S290, S700, S750DR, S800
Tmax XT1, XT2, XT3, XT4, T4320 T5
Emax
Installation choice
Fixing DIN rail DIN rail DIN rail, cable or bus bar Bus bar DIN rail, cable or bus bar,
system base mounted with feet
8
1250
1500
2000
2500
3000
4000
5000
6000
Primary choice
CTA TRF M CT PRO XT CT30 CT MAX
Wound primary Through primary Split core trough Through primary
primary
Through 8 29 18 18 – 30 30
primary – – 20x10 20x10 – 30x15; 40x10 30x15; 40x10
max
section – – – – 3x80x10 – –
[mm]
8/81
T6,T7 T6,T7
E1.2, E2.2, E4.2 E2, E3, E4, E6 E2.2, E4.2, E6.2 E2.2, E4.2 E1.2
Cable or bus bar, Bus bar Cable or bus bar, Bus bar
base mounted with feet base mounted with feet
8
CT6 CT8 CT8V CT80 CT12 CT12V CT120 Class
—
Energy efficiency
CT measurement current transformers with through primary
Technical features
CT… CTO TRFM
Standard secondary current [A] 5A
Max. voltage for operation [kV] 1,2
Test voltage [kV] 3 a 50 Hz/1min
Residual current voltage at < 25 V rms
secundary terminals when security
CT circuit intervenes (only SELV
versions)
Short circuit rated thermal current [IpN] 40 per 1 sec. 60 per 1 sec. 40 per 1 sec.
—
Energy efficiency
CT measurement current transformers with through primary
8
150 1 5 257950 CT PRO XT 150 2CSG225795R1101 0.32 1
200 1 5 258056 CT PRO XT 200 2CSG225805R1101 0.32 1
250 0.5 5 258155 CT PRO XT 250 2CSG225815R1101 0.32 1
300 0.5 5 258155 CT PRO XT 300 2CSG225825R1101 0.32 1
400 0.5 5 258353 CT PRO XT 400 2CSG225835R1101 0.32 1
CT PRO XT
series
max sec-
Through primary
tion [mm]
cable 18
vertical bar -
8/84 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
CT measurement current transformers with through primary
CT MAX series
max section
Through primary
[mm]
cable 30
vertical bar -
8/85
—
Energy efficiency
CT measurement current transformers with through primary
8
1500 0.5 30 606307 CT6/1500 2CSG421220R1101 1.000 1
2000 0.5 30 606406 CT6/2000 2CSG421230R1101 1.000 1
2500 0.5 30 606505 CT6/2500 2CSG421240R1101 1.000 1
—
Energy efficiency
CT measurement current transformers with through primary
—
Energy efficiency
CTA measurement current transformers with wound primary
8
80 0.5 5 662105 CTA/80 2CSG111110R1141 0.290 1
100 0.5 5 662204 CTA/100 2CSG111120R1141 0.290 1
CTA series
max sec-
Wound primary
tion [mm]
cable 8
horizontal bar -
vertical bar -
8/88 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
CTO split core measurement current transformers
CT120
—
Energy efficiency
TRF M measurement modular current transformers
8
150 0.5 3 047216 TRFM/150 2CSM100100R1111 0.250 1
250 0.5 4 047315 TRFM/250 2CSM100120R1111 0.250 1
400 0.5 6 047407 TRFM/400 2CSM100140R1111 0.250 1
600 0.5 8 047506 TRFM/600 2CSM100160R1111 0.250 1
8/90 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Energy efficiency
SNT current transformer for d.c. applications
Technical features
Voltage [mV] 60
Shunts
Shunts have 60 mV voltage and must be used with a maximum load of 0.25 Ω in combination
with measurement instruments in d.c.
For an appropriate operation:
8
• both horizontal and vertical mounting are possible (the horizontal position enables
a greater heat consumption)
• the faying surface must be completely used and clean; cover with specific grease
after the connection
• screws and bolts must be perfectly tight
• shunts must be sufficiently ventilated; as they are not insulated, it is a good rule
to protect them against accidental contacts.
60 mV shunts
Rated current Bbn Order details Price Weight Pack
8012542 1 1 piece unit
—
Electrical installation solutions for buildings
SMISSLINE TP plug-in system
Index
MCBs S 400 M 9/5
MCBs S 400 M-UC 9/14
MCBs SU401 M-K 9/18
MCBs SUP401 M-K 9/20
RCCBs F400 9/21
RCCBs F400 K and S 9/24
RCBOs FS401 9/25
RCBOs FS401 K 9/27
RCBOs FS403 9/28
Surge arrester 9/31
9
Switch disconnector 9/34
Auxiliary elements and accessories 9/35
Busbar system 9/40
Plug-in system
Cable laying grids, DIN rails, fixing brackets 9/76
Cover holders, panel connectors,
raising frames 9/77
Plastic cover horizontal 9/78
Plastic cover vertical 9/79
Planning aid
Socket calculation with e-Design
and Panel Design Configurator 9/80
Comparison of starting package
with plug-in socket in individual parts 9/81
Assignment of CombiLine modules 9/82
9/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Changes are never been easier
It opens up to a completely
new prospects for you when it The world’s first pluggable
comes to installation, socket system. 125Asystem and
operation and flexibility. the new 250A Power Bar system.
9/3
—
SMISSLINE TP plug-in system
Changes are never been easyer
9
Even safer: Protection against electrical hazards Even more flexible: make additions and changes during on-
We have upgraded our unique SMISSLINE socket system going operation
even further through the addition of a pioneering Pluggable devices can be added and changed quickly, safely
innovation. With the new SMISSLINE TP system, and simply during ongoing operation. And this can be done
components can now be plugged in or unplugged without any need for personal protective equipment.
load-free without any risk from electrical current
running through the body. This means that you benefit from more flexibility, savings
on installation and maintenance – and improved safety.
The SMISSLINE TP pluggable socket system is SMISSLINE TP provides greater availability and operating
completely finger-safe (IP2XB) – when devices are plugged safety than conven-tional systems.
in and unplugged, the system is always touch-proof.
This means that SMISSLINE TP prevents any danger to
personnel from switching arcs or accidental arcing.
14
1 2 3 4 5 6 7 8 9 10 11 12 13
1 Incoming block 125/160 A 6 2-pole residual current operated 12 Miniature circuit breaker 2 poles
2 Surge arrester circuit breaker 13 4-pole residual current operated
3 Control unit for Current measurement 7 4-pole residual current operated circuit breaker with overcurrent protection
system circuit breaker 14 Current measurement sensor
4 2-pole residual current operated 8 Incoming block 63 A
circuit breaker with overcurrent protection 9 Miniature circuit breaker 1 pole
5 4-pole residual current operated 10 Device latch
circuit breaker with overcurrent protection 11 Miniature circuit breaker 3 poles
9/4
4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Power behind bars
The world’s safest socket system
Small cause, large effect: as the world’s first New Power Bar System 250 A
pluggable socket system, SMISSLINE TP ensures The new 250 A system is now available in the
that load-free devices and components can be shape of the SMISSLINE TP. The busbars have
snapped on and off under voltage without a rated amperage of 250 A and therefore allow
the need for additional personal protective a end feed of 250 A. This extends the spectrum
equipment to guard against electrical hazards. of potential applications.
That opens up completely new prospects for you
when it comes to installation, operation and
flexibility.
9
9/5
—
SMISSLINE TP plug-in system
MCBs S 400 series
9
characteristics
Electrical and Mechanical Endurance ops. 10 000 ops.
Data acc. to IEC/ Max. power frequency recovery voltage (Umax) V 254/440 V AC 1P: 60 V DC 2P: 125 V DC for S400M
EN 60947-2 1P: 125 V DC 2P: 250 V DC for S400 UCC and UCZ
Rated ultimate short-circuit capacity Icu kA 25 kA (0,5 up to 16 A, 240/415 V)0,5 to 2 A 50 kA on request
15 kA (20 up to 63 A, 240/415 V)
15 kA (0,5 up to 16 A, 254/440 V)
6 kA (20 up to 63 A, 254/440 V)
S400UC: 10 kA (0,5.63A, 220 V d.c. 1pole)
S400UC: 20 kA (0,5.63A, 110 V d.c. 1pole)
S400UC: 25 kA (0,5.63A, 220 V d.c. 2pole)
S400UC: 10 kA (0,5.63A, 440 V d.c. 2pole)
S400UC: 10 kA (0,5.63A, 230/400 V)
Rated service short-circuit capacity Ics kA 15 kA (0,5 up to 16 A, 240/415 V)
7,5 kA (20 up to 63 A, 240/415 V)
6 kA (0,5 up to 16 A, 254/440 V)
3 kA (20 up to 63 A, 254/440 V
S400UC: 10 kA (0,5.63A, 220 V d.c. 1pole)
S400UC: 10 kA (0,5.63A, 110 V d.c. 1pole)
S400UC: 20 kA (0,5.63A, 220 V d.c. 2pole)
S400UC: 10 kA (0,5.63A, 440 V d.c. 2pole)
S400UC: 6 kA (0,5.63A, 230/400 V)
Dielectric test voltage kV
Reference temperature for tripping °C C: 30 °C K: 40 °C
characteristics
Electrical and Mechanical Endurance ops. In < 32 A: 20 000 operating cycles
In ≥ 32 A: 10 000 operating cycles
Mechanical Data Housing Insulation group I, RAL 7035
Toggle Insulation group II, black, sealable
Classification acc. To NF F 126-101, NF F 16-102
Protection degree acc. to EN 60529 IP20*, IP40 in enclosure with cover
Mechanical endurance ops. 20 000 ops.
Shock resistance acc. to IEC/EN 60068-2-30
Vibration resistance acc. to IEC/EN 60068-2-6 5 g – 20 cycles at 5 … 150 … 5 Hz with load 0.8 In
Environmental conditions (damp heat)
acc. to IEC/EN 60068-2-30 °C/RH 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Ambient temperature °C –25 … +55 °C
Storage temperature °C –40 … +70 °C
Installation Standed Cross-section of conductors (top/ mm2 top 0.75–25 mm2/bottom no terminal pluggable MCB
bottom)
Flexible Cross-section of conductors (top/ mm2
bottom)
Tightening torque Nm in-Ibs. 2.8 Nm
Screwdriver No. 2 Pozidrive
Mounting plug in on bus bar system SMISSLINE
Mounting position any
Supply any
Dimensions and Mounting dimensions acc. to DIN 43880
weight Pole dimensions (H x D x W) mm 91x18x82
Pole weight g 110
9/6 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
MCBs S 400 M series 10 000 B characteristic
S400M Characteristic B
Function: protection and control of the circuits against overloads and short-circuits;
protection for people and big length cables in TN and IT systems.
Applications: residential, commercial and industrial.
Standard: IEC/EN 60898
Icn =10 kA
—
SMISSLINE TP plug-in system
MCBs S 400 M series 10 000 C characteristic
S400M Characteristic C
Function: protection and control of the circuits against overloads and short-circuits;
protection for resistive and inductive loads with low inrush current.
Applications: residential, commercial and industrial.
Standard: IEC/EN 60898, IEC/EN 60947-2
Icn =10 kA
9
6 0101382 S401 M-C 6 2CCS571001R0064 0.110 10
8 0101399 S401 M-C 8 2CCS571001R0084 0.110 10
10 0101405 S401 M-C 10 2CCS571001R0104 0.110 10
13 0101412 S401 M-C 13 2CCS571001R0134 0.110 10
16 0101429 S401 M-C 16 2CCS571001R0164 0.110 10
20 0101436 S401 M-C 20 2CCS571001R0204 0.110 10
S 402 M 25 0101443 S401 M-C 25 2CCS571001R0254 0.110 10
32 0101450 S401 M-C 32 2CCS571001R0324 0.110 10
40 0101467 S401 M-C 40 2CCS571001R0404 0.110 10
50 0101474 S401 M-C 50 2CCS571001R0504 0.110 10
63 0101481 S401 M-C 63 2CCS571001R0634 0.110 10
2 0.5 0102099 S402 M-C 0.5 2CCS572001R0984 0.221 5
1 0102105 S402 M-C 1 2CCS572001R0014 0.221 5
1.6 0102112 S402 M-C 1.6 2CCS572001R0974 0.221 5
2 0102129 S402 M-C 2 2CCS572001R0024 0.221 5
3 0102136 S402 M-C 3 2CCS572001R0034 0.221 5
4 0102143 S402 M-C 4 2CCS572001R0044 0.221 5
6 0102150 S402 M-C 6 2CCS572001R0064 0.221 5
8 0102167 S402 M-C 8 2CCS572001R0084 0.221 5
10 0102174 S402 M-C 10 2CCS572001R0104 0.221 5
13 0102181 S402 M-C 13 2CCS572001R0134 0.221 5
S 403 M
16 0102198 S402 M-C 16 2CCS572001R0164 0.221 5
20 0102204 S402 M-C 20 2CCS572001R0204 0.221 5
25 0102211 S402 M-C 25 2CCS572001R0254 0.221 5
32 0102228 S402 M-C 32 2CCS572001R0324 0.221 5
40 0102235 S402 M-C 40 2CCS572001R0404 0.221 5
50 0102242 S402 M-C 50 2CCS572001R0504 0.221 5
63 0102259 S402 M-C 63 2CCS572001R0634 0.221 5
3 0.5 0102860 S403 M-C 0.5 2CCS573001R0984 0.322 3
1 0102877 S403 M-C 1 2CCS573001R0014 0.322 3
1.6 0102884 S403 M-C 1.6 2CCS573001R0974 0.322 3
2 0102891 S403 M-C 2 2CCS573001R0024 0.322 3
3 0102907 S403 M-C 3 2CCS573001R0034 0.322 3
4 0102914 S403 M-C 4 2CCS573001R0044 0.322 3
6 0102921 S403 M-C 6 2CCS573001R0064 0.322 3
8 0102938 S403 M-C 8 2CCS573001R0084 0.322 3
10 0102945 S403 M-C 10 2CCS573001R0104 0.322 3
13 0102952 S403 M-C 13 2CCS573001R0134 0.322 3
16 0102969 S403 M-C 16 2CCS573001R0164 0.322 3
20 0102976 S403 M-C 20 2CCS573001R0204 0.322 3
25 0102983 S403 M-C 25 2CCS573001R0254 0.322 3
32 0102990 S403 M-C 32 2CCS573001R0324 0.322 3
40 0103003 S403 M-C 40 2CCS573001R0404 0.322 3
50 0103010 S403 M-C 50 2CCS573001R0504 0.322 3
63 0103027 S403 M-C 63 2CCS573001R0634 0.322 3
9/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
MCBs S 400 M series 10 000 D characteristic
S400M Characteristic D
Function: protection and control of the circuits against overloads and short-circuits;
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
Applications: residential, commercial and industrial.
Standard: IEC/EN 60898
Icn =10 kA
S 401 M
Number Rated Bbn Order details Price Weight Pack
of poles current 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
MCBs S 400 M series 5 000 - 15 000 K characteristic
S400M Characteristic K
Function: protection and control of the circuits like motors, transformer and auxiliary
circuits, against overloads and short-circuits. Advantages: no nuisance tripping in the case of
functional peak currents up to 10xIn, depending on the series; through its highly sensitive ther-
mostatic bimetal trip, the K-type characteristic offers protection to damageable
elements in the overcurrent range; it also provides the best protection to cables and lines.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
S 401
Icu = 50 kA ≤ 2A, 25 kA for 3 A ≤ 16A, 15 kA for 32 A ≤ 63 A
9
2 0101634 S401 M-K 2 2CCS571001R0277 0.110 10
3 0101641 S401 M-K 3 2CCS571001R0317 0.110 10
4 0101658 S401 M-K 4 2CCS571001R0337 0.110 10
6 0101665 S401 M-K 6 2CCS571001R0377 0.110 10
8 0101672 S401 M-K 8 2CCS571001R0407 0.110 10
10 0101689 S401 M-K 10 2CCS571001R0427 0.110 10
S 402 M 13 0101696 S401 M-K 13 2CCS571001R0447 0.110 10
16 0101702 S401 M-K 16 2CCS571001R0467 0.110 10
20 0101719 S401 M-K 20 2CCS571001R0487 0.110 10
25 0101726 S401 M-K 25 2CCS571001R0517 0.110 10
32 0101733 S401 M-K 32 2CCS571001R0537 0.110 10
40 0101740 S401 M-K 40 2CCS571001R0557 0.110 10
50 0101757 S401 M-K 50 2CCS571001R0577 0.110 10
63 0101764 S401 M-K 63 2CCS571001R0597 0.110 10
2 0.5 0102372 S402 M-K 0.5 2CCS572001R0157 0.221 5
1 0102389 S402 M-K 1 2CCS572001R0217 0.221 5
1.6 0102396 S402 M-K 1.6 2CCS572001R0257 0.221 5
2 0102402 S402 M-K 2 2CCS572001R0277 0.221 5
3 0102419 S402 M-K 3 2CCS572001R0317 0.221 5
4 0102426 S402 M-K 4 2CCS572001R0337 0.221 5
6 0102433 S402 M-K 6 2CCS572001R0377 0.221 5
S 403 M 8 0102440 S402 M-K 8 2CCS572001R0407 0.221 5
10 0102457 S402 M-K 10 2CCS572001R0427 0.221 5
13 0102464 S402 M-K 13 2CCS572001R0447 0.221 5
16 0102471 S402 M-K 16 2CCS572001R0467 0.221 5
20 0102488 S402 M-K 20 2CCS572001R0487 0.221 5
25 0102495 S402 M-K 25 2CCS572001R0517 0.221 5
32 0102501 S402 M-K 32 2CCS572001R0537 0.221 5
40 0102518 S402 M-K 40 2CCS572001R0557 0.221 5
50 0102525 S402 M-K 50 2CCS572001R0577 0.221 5
63 0102532 S402 M-K 63 2CCS572001R0597 0.221 5
3 0.5 0103140 S403 M-K 0.5 2CCS573001R0157 0.322 3
1 0103157 S403 M-K 1 2CCS573001R0217 0.322 3
1.6 0103164 S403 M-K 1.6 2CCS573001R0257 0.322 3
2 0103171 S403 M-K 2 2CCS573001R0277 0.322 3
3 0103188 S403 M-K 3 2CCS573001R0317 0.322 3
4 0103195 S403 M-K 4 2CCS573001R0337 0.322 3
6 0103201 S403 M-K 6 2CCS573001R0377 0.322 3
8 0103218 S403 M-K 8 2CCS573001R0407 0.322 3
10 0103225 S403 M-K 10 2CCS573001R0427 0.322 3
13 0103232 S403 M-K 13 2CCS573001R0447 0.322 3
16 0103249 S403 M-K 16 2CCS573001R0467 0.322 3
20 0103256 S403 M-K 20 2CCS573001R0487 0.322 3
25 0103263 S403 M-K 25 2CCS573001R0517 0.322 3
32 0103270 S403 M-K 32 2CCS573001R0537 0.322 3
40 0103287 S403 M-K 40 2CCS573001R0557 0.322 3
50 0103294 S403 M-K 50 2CCS573001R0577 0.322 3
63 0103300 S403 M-K 63 2CCS573001R0597 0.322 3
9/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
MCBs S 400 M series 10 000 B characteristic
—
SMISSLINE TP plug-in system
MCBs S 400 M series 10 000 C characteristic
9
8 0103423 S401 M-C 8NP 2CCS571103R8084 0.221 5
10 0103430 S401 M-C 10NP 2CCS571103R8104 0.221 5
13 0103447 S401 M-C 13NP 2CCS571103R8134 0.221 5
16 0103454 S401 M-C 16NP 2CCS571103R8164 0.221 5
20 0103461 S401 M-C 20NP 2CCS571103R8204 0.221 5
25 0103478 S401 M-C 25NP 2CCS571103R8254 0.221 5
S 403 M
32 0103485 S401 M-C 32NP 2CCS571103R8324 0.221 5
40 0103492 S401 M-C 40NP 2CCS571103R8404 0.221 5
50 0103508 S401 M-C 50NP 2CCS571103R8504 0.221 5
63 0103515 S401 M-C 63NP 2CCS571103R8634 0.221 5
4 2 0108527 S403 M-C 2NP 2CCS573103R8024 0.428 2
3 0108534 S403 M-C 3NP 2CCS573103R8034 0.428 2
4 0108541 S403 M-C 4NP 2CCS573103R8044 0.428 2
6 0103881 S403 M-C 6NP 2CCS573103R8064 0.428 2
8 0103898 S403 M-C 8NP 2CCS573103R8084 0.428 2
10 0103904 S403 M-C 10NP 2CCS573103R8104 0.428 2
13 0103911 S403 M-C 13NP 2CCS573103R8134 0.428 2
16 0103928 S403 M-C 16NP 2CCS573103R8164 0.428 2
20 0103935 S403 M-C 20NP 2CCS573103R8204 0.428 2
25 0103942 S403 M-C 25NP 2CCS573103R8254 0.428 2
32 0103959 S403 M-C 32NP 2CCS573103R8324 0.428 2
40 0103966 S403 M-C 40NP 2CCS573103R8404 0.428 2
50 0103973 S403 M-C 50NP 2CCS573103R8504 0.428 2
63 0103980 S403 M-C 63NP 2CCS573103R8634 0.428 2
9/12 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
MCBs S 400 M series 10 000 D characteristic
—
SMISSLINE TP plug-in system
MCBs S 400 M series 5 000 - 15 000 K characteristic
9
1 0103621 S401 M-K 1NP 2CCS571103R8217 0.221 5
1.6 0103638 S401 M-K 1.6NP 2CCS571103R8257 0.221 5
2 0103645 S401 M-K 2NP 2CCS571103R8277 0.221 5
3 0103652 S401 M-K 3NP 2CCS571103R8317 0.221 5
4 0103669 S401 M-K 4NP 2CCS571103R8337 0.221 5
6 0103676 S401 M-K 6NP 2CCS571103R8377 0.221 5
S 403 M 8 0103683 S401 M-K 8NP 2CCS571103R8407 0.221 5
10 0103690 S401 M-K 10NP 2CCS571103R8427 0.221 5
13 0103706 S401 M-K 13NP 2CCS571103R8447 0.221 5
16 0103713 S401 M-K 16NP 2CCS571103R8467 0.221 5
20 0103720 S401 M-K 20NP 2CCS571103R8487 0.221 5
25 0103737 S401 M-K 25NP 2CCS571103R8517 0.221 5
32 0103744 S401 M-K 32NP 2CCS571103R8537 0.221 5
40 0103751 S401 M-K 40NP 2CCS571103R8557 0.221 5
50 0103768 S401 M-K 50NP 2CCS571103R8577 0.221 5
63 0103775 S401 M-K 63NP 2CCS571103R8597 0.221 5
4 0.5 0104086 S403 M-K 0.5NP 2CCS573103R8157 0.428 2
1 0104093 S403 M-K 1NP 2CCS573103R8217 0.428 2
1.6 0104109 S403 M-K 1.6NP 2CCS573103R8257 0.428 2
2 0104116 S403 M-K 2NP 2CCS573103R8277 0.428 2
3 0104123 S403 M-K 3NP 2CCS573103R8317 0.428 2
4 0104130 S403 M-K 4NP 2CCS573103R8337 0.428 2
6 0104147 S403 M-K 6NP 2CCS573103R8377 0.428 2
8 0104154 S403 M-K 8NP 2CCS573103R8407 0.428 2
10 0104161 S403 M-K 10NP 2CCS573103R8427 0.428 2
13 0104178 S403 M-K 13NP 2CCS573103R8447 0.428 2
16 0104185 S403 M-K 16NP 2CCS573103R8467 0.428 2
20 0104192 S403 M-K 20NP 2CCS573103R8487 0.428 2
25 0104208 S403 M-K 25NP 2CCS573103R8517 0.428 2
32 0104215 S403 M-K 32NP 2CCS573103R8537 0.428 2
40 0104222 S403 M-K 40NP 2CCS573103R8557 0.428 2
50 0104239 S403 M-K 50NP 2CCS573103R8577 0.428 2
63 0104246 S403 M-K 63NP 2CCS573103R8597 0.428 2
9/14 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
MCBs S 400 M-UC series 10 000 - 25 000 C characteristic,
DC application
S400UC Characteristic C
Function: protection and control of the circuits against overloads and short-circuits;
protection for resistive and inductive loads with low inrush current.
Applications: residential, commercial and industrial.
Standard: IEC/EN 60947-2
10 kA (0,5 up to 63 A, 220 V d.c. 1pole), 20 kA (0,5 up to 63 A, 110 V d.c. 1pole)
25 kA (0,5 up to 63 A, 220 V d.c. 2pole), 10 kA (0,5 up to 63 A, 440 V d.c. 2pole)
10 kA (0,5 up to 63 A, 230/400 V) a.c.
1 P 220V d.c. Number Rated Bbn Order details Price Weight Pack
of poles current 761227 1 piece 1 piece unit
2 2 2 4 2
9/15
—
SMISSLINE TP plug-in system
MCBs S 400 M-UC series 10 000 - 25 000 Z characteristic,
DC application
S400UC Characteristic Z
Function: protection and control of the electronic circuits against weak and long duration
overloads and short-circuits.
Applications: commercial and industrial.
Standard: IEC/EN 60947-2
10 kA (0,5 up to 63 A, 220 V d.c. 1pole), 20 kA (0,5 up to 63 A, 110 V d.c. 1pole)
25 kA (0,5 up to 63 A, 220 V d.c. 2pole), 10 kA (0,5 up to 63 A, 440 V d.c. 2pole)
10 kA (0,5 up to 63 A, 230/400 V) a.c.
9
3 0110124 S401M-UCZ3 2CCS571001R1038 0.110 10
4 0110131 S401M-UCZ4 2CCS571001R1048 0.110 10
6 0110148 S401M-UCZ6 2CCS571001R1068 0.110 10
8 0110155 S401M-UCZ8 2CCS571001R1088 0.110 10
10 0110162 S401M-UCZ10 2CCS571001R1108 0.110 10
13 0110179 S401M-UCZ13 2CCS571001R1138 0.110 10
16 0110186 S401M-UCZ16 2CCS571001R1168 0.110 10
20 0110193 S401M-UCZ20 2CCS571001R1208 0.110 10
25 0110209 S401M-UCZ25 2CCS571001R1258 0.110 10
32 0110216 S401M-UCZ32 2CCS571001R1328 0.110 10
40 0110223 S401M-UCZ40 2CCS571001R1408 0.110 10
2 P 440V d.c. 50 0110230 S401M-UCZ50 2CCS571001R1508 0.110 10
63 0110247 S401M-UCZ63 2CCS571001R1638 0.110 10
2 0.5 0110254 S402M-UCZ0.5 2CCS562001R1988 0.221 10
1 0110261 S402M-UCZ1 2CCS562001R1018 0.221 10
1.6 0110278 S402M-UCZ1.6 2CCS562001R1978 0.221 10
2 0110285 S402M-UCZ2 2CCS562001R1028 0.221 10
3 0110292 S402M-UCZ3 2CCS572001R1038 0.221 10
4 0110308 S402M-UCZ4 2CCS572001R1048 0.221 10
6 0110315 S402M-UCZ6 2CCS572001R1068 0.221 10
8 0110322 S402M-UCZ8 2CCS572001R1088 0.221 10
10 0110339 S402M-UCZ10 2CCS572001R1108 0.221 10
13 0110346 S402M-UCZ13 2CCS572001R1138 0.221 10
16 0110353 S402M-UCZ16 2CCS572001R1168 0.221 10
20 0110360 S402M-UCZ20 2CCS572001R1208 0.221 10
25 0110377 S402M-UCZ25 2CCS572001R1258 0.221 10
32 0110384 S402M-UCZ32 2CCS572001R1328 0.221 10
40 0110391 S402M-UCZ40 2CCS572001R1408 0.221 10
50 0110407 S402M-UCZ50 2CCS572001R1508 0.221 10
63 0110414 S402M-UCZ63 2CCS572001R1638 0.221 10
2 2 2 4 2
9/16 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Miniature circuit breaker (MCB) S400 M–UC, DC application, Icu = 10 … 25 kA
Load Load
1 1 1 3 1 3
2 2 2 4 2 4
Mains Mains
9/17
—
SMISSLINE TP plug-in system
Miniature circuit breaker (MCB) for UL489 240V SU401 technical
features
Technical Data
General Data
Standards UL 489, CSA 22.2 No. 5
Poles 1P
Tripping characteristics K
Rated current In 2 to 32 A
Rated frequency f 50/60 Hz
Overvoltage category III
Pollution degree 3
Calibration temperature 40 °C
Mechanical Data
Housing RAL 7035
Contact position indication Real CPI (green OFF / red ON)
Protection degree acc. to EN 60529 IP20*, IP40 in enclosure with cover
Mechanical endurance 10,000 ops.
Vibration resistance acc. to IEC/EN 60068-2-6 Frequency 2 – 13.2 Hz @1 mm Displacement;
13.2 – 100 Hz @ 0.7 g
Frequency 5 – 150 – 5 Hz @ 1 g, 4 Sweeps
9
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Ambient temperature –13 F ... +131 F; –25 … +55 °C
Storage temperature –40 F ... +158 F; –40 … +70 °C
Installation
Terminal at load side Bi-directional cylinder-lift terminal
Cross-section of conductors Solid, stranded: 35 mm2 / 35 mm2 single conductor CU only
Flexible: 25 mm2 / 25 mm2 single conductor CU only
AWG 14-8 single conductor CU only
Torque 2.8 Nm, 25 in. lbs.
Wire temperature 60/75 °C
Screwdriver No. 2 Pozidrive
Mounting SMISSLINE TP only
Mounting position Any
Pole weight 114 g
—
SMISSLINE TP plug-in system
Miniature circuit breaker (MCB) SU401 M-K for UL489 Icu 10 kA
Ordering Data
Number Rated Bbn Order details Price Weight Pack
of poles current 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
Miniature circuit breaker (MCB) for UL489 277/480 V AC SUP400 technical features
Technical Data
General Data
Standards UL 489, CSA 22.2 No. 5
Rated voltage 277/480 V AC
Poles 1P, 2P, 3P
Tripping characteristics K
Rated current In 2 to 30 A
Rated frequency f 50/60 Hz
Short circuit current rating (acc. to UL 489) 10 kA
Overvoltage category III
Pollution degree 2
Calibration temperature 40 °C
Mechanical Data
Housing RAL 7035
Toggle Black sealable
Contact position indication Real CPI (green OFF / red ON)
L1/L2/L3 position indication Yes
Protection degree acc. to EN 60529 IP20*, IP40 in enclosure with cover
9
Label holder Yes
Mechanical endurance 10,000 ops.
Shock resistance acc. to IEC/EN 61373 5 g/30 ms, 3 shocks
Vibration resistance acc. to IEC/EN 60068-2-6 2 … 13.2 Hz/1 mm
13.2 … 100 Hz/0.7 g, 5 cycles
5 … 150 … 5 Hz/1 g, 4 sweeps
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30 28 cycles with 55 °C/90 … 96 % and 25 °C/95 … 100 %
Ambient temperature –13 °F ... +131 °F; –25 … +55 °C
Storage temperature –40 °F ... +158 °F; –40 … +70 °C
Installation
Terminal at load side Failsafe bi-directional cylinder-lift terminal
with double slot 35/10 mm2
Cross-section of conductors Solid, stranded: 0.75 ÷ 35 mm2 (front slot), 0.75 ÷ 10 mm2
(rear slot), single conductor Cu only
Flexible: 0.75 ÷ 25 mm2 (front side), 0.75 ÷ 10 mm2
(rear slot), single conductor CU only
AWG 14-8 single conductor CU only
Torque 2.8 Nm, 25 in. lbs.
Stripping length 12.5 mm
Wire temperature 60/75 °C
Screwdriver No. 2 Pozidrive
Terminal at line side Movable plug-on terminal L1, L2, L3
Mounting SMISSLINE TP socket system only
Mounting position Any
Dimensions and weight
Pole weight 120 g
—
SMISSLINE TP plug-in system
Miniature circuit breaker SUP400 for branch circuit protection acc. to UL489
File E312425
Ordering Data
Number Rated Bbn Order details Price Weight Pack
of poles current In 761227 1 piece 1 piece unit
Ordering Data
Number Rated Bbn Order details Price Weight Pack
of poles current In 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
RCCBs F400 series, A y type
F402 A type
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contacts and additional protection against direct
(with IΔn = 30 mA) contacts.
Application: residential, commercial, industrial.
Standard: IEC/EN 61008
Marking: according to EN 61008
F402 Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 801254 1 piece 1 piece unit
current
IDn mA In A EAN Type code Order code kg pc.
2 10 25 2037033 F402 A 25/0.01 2CSF502110R0250 0.250 1
30 25 2034339 F402 A 25/0.03 2CSF502110R1250 0.250 1
30 40 2036937 F402 A 40/0.03 2CSF502110R1400 0.250 1
100 40 2034230 F402 A 40/0.1 2CSF502110R2400 0.250 1
9
F404 A type
Function: protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contacts and additional protection against direct
F404 (with IΔn = 30 mA) contacts. Product helpful where for installation habits, for wiring with
busbars or cables, for special needs neutral on the left is needed.
Application: residential, commercial, industrial.
Standard: IEC/EN 61008
Marking: according to EN 61008
—
SMISSLINE TP plug-in system
RCCBs F400 series, A APR y type
performance MCB
S800 100 A
Connection Double lift terminal touch finger-proof, suitable for connecting
load side terminal single-, multi- and fine-wire conductors of up to 25 mm2
Degree of protection: IP20 in panel IP40 IP20 in panel IP40 IP20 in panel IP40 IP20 in panel IP40
Endurance: > 5000 operating > 5000 operating > 5000 operating
cycles cycles cycles
Resistance to climate EN 61008 EN 61008 EN 61008 EN 62423
acc. to:
Mounting position: any any any any
Ambient –25°C … +40°C –25°C … +55°C –25°C … +40°C –25°C … +40 °C
temperature:
Vibration resistance: 5 g 5 g 5 g 5 g
5 … 150 … 5 Hz 5 … 150 … 5 Hz 5 … 150 … 5 Hz 5 … 150 … 5 Hz
Plastic parts: halogen-free halogen-free halogen-free halogen-free
Contacts: cadmium-free cadmium-free cadmium-free cadmium-free
9/23
—
SMISSLINE TP plug-in system
RCCB F404 series - B type for continuous,
selective continuous type fault currents technical features
F404 B RCCBs provide additional protection against direct contact and are the
right choice to ensure maximum system safety thanks to early detection of fault
currents with continuous waveforms or high frequencies.
Number Rated Rated Bbn Order details Price Weight Pack
of poles residual current 761227 1 piece 1 piece unit
current
IΔn mA In A EAN Type code Order code kg pc.
4 30 25 1506285 F404B-25/0.03 2CCG000052R0001 0.435 1
4 30 40 1506292 F404B-40/0.03 2CCG000053R0001 0.435 1
F 404 B
4 30 63 1506308 F404B-63/0.03 2CCG000054R0001 0.435 1
4 300 25 1506315 F404B-25/0.3 2CCG000055R0001 0.435 1
4 300 40 1506322 F404B-40/0.3 2CCG000056R0001 0.435 1
4 300 63 1506339 F404B-63/0.3 2CCG000057R0001 0.435 1
9
9/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
RCCBs F400 series, A K y type
—
SMISSLINE TP plug-in system
RCBOs FS401 series 10 000 - 6000 A and F y type
9
Resistance to climate, acc. to: EN 61009
Mounting position: any
Ambient temperature: –25°C ... +40°C
Vibration resistance: 5 g
5 ...150 ... 5 Hz
Plastic parts: halogen-free
Contacts: cadmium-free
Standard EN61009-1, SEV, VDE
Please notice:
For the influence of the ambient temperature and the thermal influences of row mounted RCBO’s it is necessary to calculate
with the same correction factors like with MCB’s.
—
SMISSLINE TP plug-in system
RCBOs FS401 series 10 000 - 6000 A y type
B, 10 kA according to EN 61009-1
30 6 10 1472641 FS401 M-B 6/0.03 2CCL562110E1065 2 0.2 1
30 10 10 0109685 FS401 M-B 10/0.03 2CCL562110E0105 2 0.2 1
30 13 10 0104505 FS401 M-B 13/0.03 2CCL562110E0135 2 0.2 1
30 16 10 0104512 FS401 M-B 16/0.03 2CCL562110E0165 2 0.2 1
30 20 10 1472689 FS401 M-B 20/0.03 2CCL562110E1205 2 0.2 1
30 25 10 1472726 FS401 M-B 25/0.03 2CCL562110E1255 2 0.2 1
30 32 10 1472764 FS401 M-B 32/0.03 2CCL562110E1325 2 0.2 1
—
SMISSLINE TP plug-in system
RCBOs FS401 series 10 000 A K y Type F
9
30 10 10 1472887 FS401 M K-B 10/0.03 2CCL562310E1105 2 0.2 1
30 13 10 1472900 FS401 M K-B 13/0.03 2CCL562310E1135 2 0.2 1
30 16 10 1472924 FS401 M K-B 16/0.03 2CCL562310E1165 2 0.2 1
30 20 6 1472962 FS401 M K-B 20/0.03 2CCL562310E1205 2 0.2 1
30 25 6 1473006 FS401 M K-B 25/0.03 2CCL562310E1255 2 0.2
30 32 6 1473044 FS401 M K-B 32/0.03 2CCL562310E1325 2 0.2 1
—
SMISSLINE TP plug-in system
RCBOs FS403 series 10 000 - 6000 A y type and
short time delay Type F
FS403
Rated voltage Un 240/415V
Number of poles 4
Rated frequency fn 50/60 Hz
Rated breaking capacity Icn 10 kA (10 A to 16 A)
6 kA (20 A to 32 A)
Current limitation class 3
Total cut-off time acc. to EN 61009
at In 40 ms
FS 403 M
at 5x In 25 ms
Connection cross-section max. 25 mm2 flexible wire with wire end sleeve
Terminal at load side Possible to connect 2 wires in one chamber.
Both chambers could be used with two different
cross-sections.
Tightening torque 2.8 Nm
Degree of protection IP20
9
Endurance >5000
Resistance to climate EN 61009
Ambient temperature –25° C … +40° C
Mounting position any
Vibration resistance EN 61009
Plastic parts halogen-free
Contacts cadmium-free
Standard EN61009-1, SEV, VDE
Accessory:
Auxiliary- and signal contacts are to attach on to the left of the device through the customer.
Please notice:
For the influence of the ambient temperature and the thermal influences of row mounted RCBO’s it is necessary to calculate
with the same correction factors like with MCBs.
Please see in Chapter 2 of Electrical installation solutions for buildings - Technical details.
—
SMISSLINE TP plug-in system
RCBOs FS403 series 10 000 - 6000 A y type and
short time delay Type F
FS403 M A type, B and C characteristic
Function: protection of end user single-phase circuits against overload and short-circuit
currents; protection against the effects of sinusoidal alternating and direct pulsating earth
fault currents; protection against indirect contact and additional protection against direct
contact (IΔn = 30 mA).
Application: residential, commercial, industrial.
Standard: IEC/EN 61009, Icn = 6 kA, Icn =10 kA
9
20 10 1442576 FS403M-B20/0.03 2CCL563110E0205 0.410 1
25 10 1442590 FS403M-B25/0.03 2CCL563110E0255 0.410 1
32 10 1442613 FS403M-B32/0.03 2CCL563110E0325 0.410 1
—
SMISSLINE TP plug-in system
RCBOs FS403 series 10 000 - 6000 A y type and
short time delay Type F
B, 10 kA according to EN61009-1 short time delayed (APR) Type F
Poles Sensi- Rated Rated Bbn Order details Price Weight Pack
tivity current breaking 761227 1 1 piece unit
capacity piece
IDn mA In A Icn kA EAN Type code Order code kg pc.
4 30 6 10 1470951 FS403MK-B6/0.03 2CCL564310E0065 0.410 1
10 10 1470999 FS403MK-B10/0.03 2CCL564310E0105 0.410 1
13 10 1471033 FS403MK-B13/0.03 2CCL564310E0135 0.410 1
16 10 1471071 FS403MK-B16/0.03 2CCL564310E0165 0.410 1
FS 403 M 20 10 1470777 FS403MK-B20/0.03 2CCL564310E0205 0.410 1
25 10 1470814 FS403MK-B25/0.03 2CCL564310E0255 0.410 1
32 10 1470852 FS403MK-B32/0.03 2CCL564310E0325 0.410 1
—
SMISSLINE TP plug-in system
Surge arrester
The type 2 surge arresters in the QuickSafe product range are suitable for protecting e
lectrical
low voltage systems and terminals in the 240/415 V system. The devices can be used as type 2
surge arresters within the scope of the lightning protection zone concept at zone transition
0B–1 and higher. The high nominal discharge capability of 20 kA makes it possible for the equip-
ment to have a longer service life in comparison to the minimum requirements of the standard.
The devices consist of a basic unit and pluggable protection modules, which can be removed
extremely easily to carry out insulation measurement. They are fully compatible with SMISSLINE
installation devices and the surge arresters in the ABB System pro M model series. The surge ar-
resters are tested as type 2 arresters in accordance with the EN/IEC 61643-11 test standard.
Mounting
The over voltage protection device “OVR” will be installed near the front of the protected
consumers conditioning.
The surge arrester is to be mounted right after the Incoming block of the socket system.
The OVR404 is snapped directly onto the SMISSLINE bus bar system.
9
2CCC451191Z0001
9/32 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Surge arrester
Electrical features
Standard IEC 61643-11/EN 61643-11 IEC 61643-11/EN 61643-11
Type / test class Type 2 Type 2
Number of pole 4 4
Nominal voltage UN (L-N, L-L) 240/415 V 240/415 V
Type of voltage a. c. 45–65 Hz a. c. 45–65 Hz
Max. cont. operating voltage Uc 275 V AC 275 V AC
Nominal discharge current In (8/20) 20 kA 20 kA
Maximum discharge current Imax (8/20) 40 kA 40 kA
Maximum impulse current Iimp (10/350) 2 kV 2 kA
Voltage protection level Up at In (L-N / N-PE / L-PE) 1.5 kV 1.25/1.4/1.5 kV
Voltage protection level Up at 3 kA (L-N / N-PE / L-PE) 0.5 kV 0.8/1.4/0.85 kV
9
Installation
Wire range (L, N, PE) 2.5…25 mm² 2.5…25 mm²
cable or rope cable or rope
Connection cross-section 2.5…16 mm² litz wire with ferrule 2.5…16 mm² litz wire with ferrule
Tightening torque 2.8 Nm 2.8 Nm
Back up protection
Typ 2 QuickSafe® Prospective short circuit Circuit breaker maximum ratings 1) Fuse 2)
Surge Protective Devices current at SPD location (Ip) curve B or C (gL - gG)
Maximum ratings
In: 5, 20, 30 kA 0,625 kA < Ip < 100 kA S800S B or C – 125 A 2) 125 A fuse
Uc: 275, 350, 440, 600 V
1) Maximum ratings, must be in accordance with the installation to follow coordination rules with main or upstream short circuit protection(s).
2) up to Ip ≤ 50 kA
9/33
—
SMISSLINE TP plug-in system
Surge arrester
Isn (8/20 µs)
kA EAN Type code Order code kg pc.
20 1455491 OVR404 4L 2CCF606000R0001 0.470 1
40-275 P TS
QS
20 1455507 OVR404 3N 2CCF606002R0001 0.450 1
OVR404 40-275 P TS
QS
9
9/34 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Switch disconnector
—
SMISSLINE TP plug-in system
Auxiliary elements and accessories
2 HK / 1 HK, 1 SK
AS400 / ZLS931
AS400 / ZLS931
AS400 / ZLS931
2 HK / 1HK, 1 SK
2 HK / 1HK, 1 SK
S2C-A1/A2
F4C-CM
F4C-ARI
ZLS728
NT402
NT401
HK
HK
HK
SK
SK
SK
T
F404 L2
S400
AS400 / ZLS931
2 HK / 1 HK, 1 SK
2 HK / 1 HK, 1 SK
AS400 / ZLS931
AS400 / ZLS931
9
F4C-CM
F4C-ARI
2 HK
HK
HK
HK
SK
SK
T
T T
N
L2 L2
IS404
FS401 FS402
2 SBH / 1 SBS, 1 SBH
2 HK / 1 HK, 1 SK
AS400 / ZLS931
SBS10 / SBS01
1 auxiliary switch
HK
SK
or 1 signal contact
or 2 auxiliary contact switches
or 1 auxiliary switch and 1 signal contact 1 3 5
L1 L2 L3
T1 T1 T1
2 4 6 N
MS325 FS403
Contact description signal contact
97 05 97 07 95 05
98 06 98 08 96 06
SK40011 SK40020 SK40002
14 22 14 24 12 22
9/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Adapter for motor starter MS116, MS132, MS325
—
SMISSLINE TP plug-in system
Auxiliary switch and signal contacts
MCB S400, RCCB F404, RCCB F402, RCBO FS401
Technical data for auxiliary switch and signal contact
Signal contact Auxiliary switch
SK400 HK400
Rated voltage Un 400 V 400 V
Rated impulse withstand voltage 4 kV 4 kV
Rated current
– Ith 6 A 6 A
– AC15 2 A/230 V / 1 A/400 V 2 A/230 V / 1 A/400 V
– DC13 0.55 A/125 V= 0.55 A/125 V=
– DC13 0.27 A/250 V= 0.27 A/250 V=
Minimum current/voltage 10 mA 12 V= 10 mA 12 V=
(to ensure reliable electrical operation)
Connection cross-sections 2 x 1.5 mm2 strand with sleeve 2 x 1.5 mm2 strand with sleeve
Plastic parts Free of halogen und cadmium Free of halogen und cadmium
Internal resistance Ri 0.0065 Ω 0.0065 Ω
Power loss at rated current Pv 0.24 W 0.24 W
Ambient temperature Tmax. +55 ºC Tmin –25 ºC Tmax. +55 ºC Tmin –25 ºC
9
Tightening torque 1 Nm 1 Nm
9/38 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Auxiliary switch and signal contacts
MCB S400, RCCB F404, RCCB F402, RCBO FS401
Auxiliary switch
The auxiliary switch and signal contacts are supplied with one contacting piece. The signal con-
tact collective alarm are supplied with two contacting pieces.
for left side mounting on MCB S400, RCCB F402, RCBO FS401, FS403
Bbn Order details Price Weight Pack
761227 1 piece 1 piece unit
HK400..L
EAN Type code Order code kg pc.
1NO and 1NC 0100910 HK40011-L 2CCS500900R0081 0.045 10
2NO 0111183 HK40020-L 2CCF201112R0001 0.040 10
2NC 0111190 HK40002-L 2CCF201114R0001 0.040 10
for right side mounting on RCCB F404, MCB S400 and IS404
1NO and 1NC 0108619 HK40011-R 2CCS500900R0214 0.045 10
2NO 0111206 HK40020-R 2CCF201113R0001 0.040 10
2NC 0111213 HK40002-R 2CCF201115R0001 0.040 10
9
HK400..R
Signal contacts
for left side mounting on MCB S400, RCCB F402, RCBO FS401, FS403
Bbn Order details Price Weight Pack
761227 1 piece 1 piece unit
SK400..L
for right side mounting on RCCB F404 and MCB S400
1NO and 1NC 0108626 SK40011-R 2CCS500900R0215 0.045 10
2NO 0111121 SK40020-R 2CCF201163R0001 0.040 10
2NC 0111138 SK40002-R 2CCF201165R0001 0.040 10
—
SMISSLINE TP plug-in system
Dummy, housing, Neutral disconnector, shunt trip
9
Contacting piece for 0100972 ZLS632 2CCS500900R0171 0.200 Pack
HK/SK LA, LB contains
Pack contains 100 100 items
items
Contacting piece for 0109265 ZLS635 2CC5201307R0171 0.020 Pack
HK/SK LA, LB contains
Pack contains 10 items 10 items
Contact Pin 0108640 ZLS633 2CCS500900R0201 Pack
contains
10 items
Neutral disconnector
On the load side terminal two separate conductors can be clamped
Connection Bbn Order details Price Weight Pack
support 761227 1 piece 1 piece unit
Shunt trip
Function: remote opening of the device when a voltage is applied.
Suitable for MCBs S400 series.
Rated voltage Bbn Order details Price Weight Pack
801254 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
Approvals according to IEC/EN 61439-6. Busbar system 125 A.
Rated conditional short-circuit Incoming current of main busbars Short circuit protection device
current (Icc) (L1, L2, L3, N) (SCPD)
Fuse MCCB
ABB
250 A
Tmax 250 A
NH1 gG ABB
200 A
690 V/200 A Tmax 250 A
NH1 gG ABB
160 A
50 kA (690 V) 690 V/160 A Tmax 250 A
ABB
NH00 gG
63 A Type S803S in combination with
690 V/63 A
Type S803S-SCL63-SR
Incoming current
of auxiliary busbars (LA LB)
NH00 gG ABB
50 kA (415 V) 40 A
690 V/40 A Type S800 with 240 V/415 V
Rated Voltage (Ue) Rated conditional Incoming current of main Short circuit protection device
short-circuit current (Icc) busbars (L1, L2, L3, N) (SCPD)
Fuse MCCB
415 V 100 kA 250 A NH1 gG 690 V/250 A ABB
Tmax T4/XT4 250 A
690 V 25 kA 250 A NH1 gG 690 V/250 A ABB
Tmax T4/XT4 250 A
Incoming current
of auxiliary busbars (La Lb)
25 kA 40 A NH00 gG 415 V/40 A ABB
Type S800 with
(240 V/415 V AC)
9/41
—
SMISSLINE TP plug-in system
Busbar system 125 A
Technical data UL508 Industrial Control Equipment (ZLS906, ZLS908, ZLS920, ZLS926, ZLS928)
Busbar Feeder Feeder block Combimodule Universal Terminals Combi modul Adapter moter
ZLS200 ZLS924 ZLS95X ZLS840X, 842X adpter ZLS95XUL, ZMS132X strater ZMS93X
ZLS97X 91XUL
Maximum 600 V AC 600 V AC 600 V AC 600 V AC 600 V AC 600 V AC 600 V AC 600 V AC
rated voltage
9
Maximum 125 A 150 A 150A 30 A 32 A, 63 A 32 A, 100 A, 32 A 32 A
rated current 150 A
—
SMISSLINE TP plug-in system
Starter pack Touch proof 3L – 125 A system
—
SMISSLINE TP plug-in system
Starter pack Touch proof 3LN – 125 A system
Starter Pack 3LN: L1, L2, L3, N inclusive socket end piece
Solutions Busbars length Busbars length Bbn Order details Price Weight Pack
available incl. Socket 761227 1 piece 1 piece unit
end piece
mm mm EAN Type code Order code kg pc.
18 PLE 3LN 364 320 1426521 ZLS905E18-3LN 2CCA183234R0001 0.615 1
20 PLE 3LN 401 355 1413248 ZLS905E20-3LN 2CCA183101R0001 0.724 1
22 PLE 3LN 437 391 1413262 ZLS905E22-3LN 2CCA183103R0001 0.789 1
24 PLE 3LN 473 427 1413286 ZLS905E24-3LN 2CCA183105R0001 0.800 1
9
26 PLE 3LN 509 463 1413408 ZLS905E26-3LN 2CCA183107R0001 0.926 1
28 PLE 3LN 545 499 1413422 ZLS905E28-3LN 2CCA183109R0001 0.970 1
30 PLE 3LN 581 535 1413446 ZLS905E30-3LN 2CCA183111R0001 1.046 1
32 PLE 3LN 617 571 1413460 ZLS905E32-3LN 2CCA183113R0001 1.120 1
34 PLE 3LN 653 607 1413484 ZLS905E34-3LN 2CCA183115R0001 1.193 1
36 PLE 3LN 689 643 1413507 ZLS905E36-3LN 2CCA183117R0001 1.2.57 1
38 PLE 3LN 725 679 1413521 ZLS905E38-3LN 2CCA183119R0001 1.322 1
40 PLE 3LN 761 715 1413545 ZLS905E40-3LN 2CCA183121R0001 1.387 1
42 PLE 3LN 797 751 1413569 ZLS905E42-3LN 2CCA183123R0001 1.459 1
44 PLE 3LN 833 787 1413583 ZLS905E44-3LN 2CCA183125R0001 1.524 1
46 PLE 3LN 869 823 1413606 ZLS905E46-3LN 2CCA183127R0001 1.589 1
48 PLE 3LN 905 859 1413620 ZLS905E48-3LN 2CCA183129R0001 1.653 1
50 PLE 3LN 941 896 1413644 ZLS905E50-3LN 2CCA183131R0001 1.726 1
52 PLE 3LN 977 932 1413668 ZLS905E52-3LN 2CCA183133R0001 1.791 1
54 PLE 3LN 1013 968 1413682 ZLS905E54-3LN 2CCA183135R0001 1.855 1
56 PLE 3LN 1049 1004 1413705 ZLS905E56-3LN 2CCA183137R0001 1.920 1
58 PLE 3LN 1058 1040 1413729 ZLS905E58-3LN 2CCA183139R0001 1.992 1
60 PLE 3LN 1122 1076 1413743 ZLS905E60-3LN 2CCA183141R0001 2.057 1
62 PLE 3LN 1158 1112 1413767 ZLS905E62-3LN 2CCA183143R0001 2.122 1
64 PLE 3LN 1194 1148 1413781 ZLS905E64-3LN 2CCA183145R0001 2.186 1
66 PLE 3LN 1230 1184 1413804 ZLS905E66-3LN 2CCA183147R0001 2.259 1
68 PLE 3LN 1266 1220 1413828 ZLS905E68-3LN 2CCA183149R0001 2.324 1
70 PLE 3LN 1302 1256 1413842 ZLS905E70-3LN 2CCA183151R0001 2.388 1
72 PLE 3LN 1338 1292 1413866 ZLS905E72-3LN 2CCA183153R0001 2.453 1
74 PLE 3LN 1374 1328 1413880 ZLS905E74-3LN 2CCA183155R0001 2.526 1
76 PLE 3LN 1410 1364 1413903 ZLS905E76-3LN 2CCA183157R0001 2.590 1
78 PLE 3LN 1446 1400 1413927 ZLS905E78-3LN 2CCA183159R0001 2.655 1
80 PLE 3LN 1482 1436 1413941 ZLS905E80-3LN 2CCA183161R0001 2.719 1
9/4 4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Starter pack Touch proof 3L LA LB – 125 A system
Starter Pack 3LLALB: L1, L2, L3, LA, LB inclusive socket end piece
Solutions Busbars length Busbars length Bbn Order details Price Weight Pack
available incl. Socket 761227 1 piece 1 piece unit
end piece
mm mm EAN Type code Order code kg pc.
18 PLE 3L LA LB 364 320 1426538 ZLS905E18-3LLALB 2CCA183233R0001 0.586 1
20 PLE 3L LA LB 401 355 1416904 ZLS905E20-3LLALB 2CCA183162R0001 0.753 1
22 PLE 3L LA LB 437 391 1416911 ZLS905E22-3LLALB 2CCA183164R0001 0.821 1
24PLE 3L LA LB 473 427 1416928 ZLS905E24-3LLALB 2CCA183166R0001 0.835 1
9
—
SMISSLINE TP plug-in system
Starter pack Touch proof 3LN LA LB – 125 A system
2CCC451692F0002
Starter Pack 3LNLALB: L1, L2, L3, N, LA, LB inclusive socket end piece
Solutions Busbars length Busbars length Bbn Order details Price Weight Pack
available incl. Socket 761227 1 piece 1 piece unit
end piece
mm mm EAN kg pc.
Type code Order code
18 PLE 3LN LA LB 364 320 1426545 ZLS905E18-3LNLALB 2CCA183235R0001 0.671 1
20 PLE 3LN LA LB 401 355 1417215 ZLS905E20-3LNLALB 2CCA183163R0001 0.841 1
22 PLE 3LN LA LB 437 391 1417222 ZLS905E22-3LNLALB 2CCA183165R0001 0.917 1
24PLE 3LN LA LB 473 427 1417239 ZLS905E24-3LNLALB 2CCA183167R0001 0.939 1
9
26PLE 3LN LA LB 509 463 1417246 ZLS905E26-3LNLALB 2CCA183169R0001 1.078 1
28PLE 3LN LA LB 545 499 1417253 ZLS905E28-3LNLALB 2CCA183171R0001 1.133 1
30PLE 3LN LA LB 581 535 1417260 ZLS905E30-3LNLALB 2CCA183173R0001 1.238 1
32PLE 3LN LA LB 617 571 1417277 ZLS905E32-3LNLALB 2CCA183175R0001 1.306 1
34PLE 3LN LA LB 653 607 1417284 ZLS905E34-3LNLALB 2CCA183177R0001 1.391 1
36PLE 3LN LA LB 689 643 1417291 ZLS905E36-3LNLALB 2CCA183179R0001 1.467 1
38PLE 3LN LA LB 725 679 1417307 ZLS905E38-3LNLALB 2CCA183181R0001 1.543 1
40PLE 3LN LA LB 761 715 1417314 ZLS905E40-3LNLALB 2CCA183183R0001 1.619 1
42PLE 3LN LA LB 797 751 1417321 ZLS905E42-3LNLALB 2CCA183185R0001 1.704 1
44PLE 3LN LA LB 833 787 1417338 ZLS905E44-3LNLALB 2CCA183187R0001 1.780 1
46PLE 3LN LA LB 869 823 1417345 ZLS905E46-3LNLALB 2CCA183189R0001 1.856 1
48PLE 3LN LA LB 905 859 1417352 ZLS905E48-3LNLALB 2CCA183191R0001 1.933 1
50PLE 3LN LA LB 941 896 1417369 ZLS905E50-3LNLALB 2CCA183193R0001 2.017 1
52PLE 3LN LA LB 977 932 1417376 ZLS905E52-3LNLALB 2CCA183195R0001 2.093 1
54PLE 3LN LA LB 1013 968 1417383 ZLS905E54-3LNLALB 2CCA183197R0001 2.169 1
56PLE 3LN LA LB 1049 1004 1417390 ZLS905E56-3LNLALB 2CCA183199R0001 2.246 1
58PLE 3LN LA LB 1058 1040 1417406 ZLS905E58-3LNLALB 2CCA183201R0001 2.330 1
60PLE 3LN LA LB 1122 1076 1417413 ZLS905E60-3LNLALB 2CCA183203R0001 2.406 1
62PLE 3LN LA LB 1158 1112 1417505 ZLS905E62-3LNLALB 2CCA183205R0001 2.482 1
64PLE 3LN LA LB 1194 1148 1419172 ZLS905E64-3LNLALB 2CCA183207R0001 2.559 1
66PLE 3LN LA LB 1230 1184 1417420 ZLS905E66-3LNLALB 2CCA183209R0001 2.643 1
68PLE 3LN LA LB 1266 1220 1417437 ZLS905E68-3LNLALB 2CCA183211R0001 2.719 1
70 PLE 3LN LA LB 1302 1256 1417444 ZLS905E70-3LNLALB 2CCA183213R0001 2.796 1
72PLE 3LN LA LB 1338 1292 1417451 ZLS905E72-3LNLALB 2CCA183215R0001 2.872 1
74PLE 3LN LA LB 1374 1328 1417468 ZLS905E74-3LNLALB 2CCA183217R0001 2.956 1
76PLE 3LN LA LB 1410 1364 1417475 ZLS905E76-3LNLALB 2CCA183219R0001 3.032 1
78PLE 3LN LA LB 1446 1400 1417482 ZLS905E78-3LNLALB 2CCA183221R0001 3.109 1
80PLE 3LN LA LB 1482 1436 1417499 ZLS905E80-3LNLALB 2CCA183223R0001 3.185 1
9/46 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Socket
Snap mounting
Pull down the slide with a screwdriver until it latches (socket can be moved).
Press on front of slid:
Fixed position
(Sockets fixed)
Socket base
Description/ Bbn Order details Price Weight Pack
application 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
Busbars, Socket end piece – 125 A system
1979 mm. The same busbar type is used, regardless whether it is fitted in the socket (L1, L2,
L3, N) or in the additional socket (N, PE). The busbars are inserted in to the socket from the
front.
ZLS20 Auxiliary busbars for the socket ZLS202
The 5 x 2 mm auxiliary busbars are intended for a common power supply of auxiliary switches
and signal contacts. They are also plated and their max. delivery length is 1979 mm.
Like the main busbars, the auxiliary busbars are inserted in holders LA and LB from the front.
Of course, only on auxiliary busbar can be fitted.
Busbars for the sockets
Description/ Bbn Order details Price Weight Pack
application 761227 1 piece 1 piece unit
9
1979 mm
40 A auxiliary busbar 0015719 ZLS202 2CCF002773R0001 0.240 10
plated,
5 x 2 mm, for LA und LB
– Delivery length
1979 mm
—
SMISSLINE TP plug-in system
Incoming terminal block and components – 125 A system
act directly on the busbars and thereby fix the incoming terminal component. The incoming ter-
minal component, L1, L2, L3 and N can be combined to meet specific needs. A maximum cable
cross-section of 95 mm2 can be connected to the incoming terminal component.
Incoming terminal component 10 mm2 to 95 mm2 max. 1 wire
Version Bbn Order details Price Weight Pack
ZLS95 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
Incoming terminal block and components – 125 A system
General
The incoming terminal block is used to connect cables directly to the busbars. The terminals
act directly on the busbars and therefore fix the incoming terminal block. Removable
terminal tops permit the connection of continous conductrors (risers) white horizontal
or vertical cable entry is also possible.
Instead of using the incoming terminal block, the power supply can also be realized via
a device (e.g. residual current operated circuit breaker, miniature circuit breaker or switch
disconnector).
9
Power supply in centre, maximum 160 A.
A maximum of 125 A is permitted on either side. A total of 160 A must not be exceeded.
—
SMISSLINE TP plug-in system
Incoming terminal block and components
—
SMISSLINE TP plug-in system
Terminals for additional socket – 125 A system
Additional socket
The additional socket can easily be fitted onto the socket base to accomodate the external N
and/or PE busbars. This enables neutral connections to be made where single-pole
miniature circuit breakers are used with unswitched neutral. Neutral terminals are clipped
onto the additional socket and can be used as detachable neutral connections. One N
ZLS928 busbar and/or one PE busbar can be fitted. Each socket base can be equipped with an
additional socket. Because it contains an integrated 35 mm DIN-rail snap-on feature, the ex-
ternal N or PE busbars can be fitted anywhere in the distribution panel, even separatly from
the system. The additional sockets can be covered to prevent accidental contact with live
parts.
9
ZLS926 -module socket
8 1420444 ZLS928 2CCA183630R0001 0.034 10
(suitable for 8-module
socket)
-module socket
6 1420437 ZLS926 2CCA183635R0001 0.026 10
(suitable for 6-module
socket)
9/52 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Terminals TP, additional socket
EAN kg pc.
PE 10 mm2 1487041 ZLS919 2CCA183441R0001 0.012 Set à 10
PE 35 mm2 1486921 ZLS929 2CCA183387R0001 0.030 10
PE 95 mm2 1487164 ZLS959 2CCA672510R0001 0.100 1
Insulator block
The dark grey insulator block isolates the interrupted bus bar ends from one another and si-
multaneously marks the disconnection point externally.
Description/ Bbn Order details Price Weight Pack
application 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
Terminal range UL
9
Description/ Bbn Order details Module Weight Pack
application 761227 Type code Order code 1 piece unit
EAN kg pc.
PE 10 mm2 max. 8AWG 1487140 ZLS919UL 2CCA183447R0001 0.5 0.011 1
PE 35 mm2 max. 2AWG 1486969 ZLS929UL 2CCA183399R0001 1 0.030 1
PE 95 mm2 max. 1/0AWG 1487201 ZLS959UL 2CCA672512R0001 2 0.088 1
Insulator block
The dark grey insulator block isolates the interrupted bus bar ends from one another
and simultaneously marks the disconnection point externally.
Description/ Bbn Order details Module Weight Pack
application 761227 1 piece unit
—
SMISSLINE TP plug-in system
Socket accessories
Intermediate piece
Description/ Bbn Order details Price Weight Pack
application 761227 1 piece 1 piece unit
Busbar insulator
dark grey, for isolation and 1418205 ZLS938 2CCA205611R0001 0.001 1
spacing of separate busbar
sections, 18 mm
Busbar cover
electrically protected 0015603 ZLS100 2CCF002762R0001 0.095 1
covering of main and
auxiliary busbars.
The 4 modules cover can be
divided.
Suitable to accept
extension adapter ZLS 101
4 x18 mm
– bag containing 5 items
Add-on adapter
18 mm wide, can be plugged 0015610 ZLS101 2CCF002763R0001 0.002 10
on busbar cover ZLS100.
To mount conventional DIN
devices with 45 m cap size.
– bag containing 10 items
9/55
—
SMISSLINE TP plug-in system
Combi module 32 A (lN), 6 A (lA, lB)
MS116/132 + AF contactor
Combi module for MS116/MS132 and AF contactor
Description/ Bbn Order details Price Weight Pack
application 761227 1 piece 1 piece unit
9
piece 9 mm
Adapter MS116/132 1503208 ZMS132- 2CCF182543R0001 0.105 1
L123L wire bottom feed 3LWB
Combi module for MS116/MS132 and AF contactors for push in terminals
Adapter MS116/132 1503178 ZMS132- 2CCF182540R0001 0.105 1
L123 wire top feed 3L-PI
For push terminals
Adapter MS116/132 1503185 ZMS132- 2CCF182541R0001 0.105 1
L123LB wire top feed 3LB-PI
For push terminals
Adapter MS116/132 1503192 ZMS132- 2CCF182542R0001 0.105 1
L123LAB wire top feed 3LAB-PI
For push terminals
The 9 mm wide additional housing is need to use when an unequal number (1, 3, 5, …) of combi modules or adapter are plugged
on the socket. This is needed to fill the space into a full module (18 mm).
The 9 mm wide additional housing can be also use when on one side of the manual motor starter an auxiliary contact is mounted.
The order codes of manual motor starter and the contactors auf in the ABB catalogue DOC 1SBC100155C0202 or in the local
ABB catalogue.
9/56 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Combi module 32 A (lN), 6 A (lA, lB)
MS116/132 + AF contactor
Adapter for manual motor starter MS116 and MS132
Description/ Bbn Order details Price Weight Pack
application 761227 1 piece 1 piece unit
—
SMISSLINE TP plug-in system
Locking device
Locking device
Padlock adapter 3 mm 0104833 SA 1 GJF1101903R0001 0.023 1
– Bag containing 10
items
Padlock 0104857 SA 2 GJF1101903R0002 0.020 1
SA
9
9/58 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Universal adapters 32 A and 63 A
ZLS97X ZLS97X
Universal Adapter
ZLS97X ZLS97XN
Multipole universal adapter can plugged
together with single adapters and the
connection piece E210SPV.
C US C US C US C US C US C US C US C US
L3–L2–L1
L1 or L2 or L3
L1 or L2 or L3
L1 or L2 or L3
N
E210-SPV N
Adapter 63A
L1/L2/L3 wire top ZLS972 1 144 4709 ZLS972 2CCA180555R0001 0.024 1
L1/L2/L3 wire bottom 1 144 4716 ZLS973 2CCA180556R0001 0.024 1
ZLS973
N wire top ZLS972N 1 144 4808 ZLS972N 2CCA180557R0001 0.024 1
N wire bottom ZLS973N 1 144 4730 ZLS973N 2CCA180558R0001 0.024 1
Adapter 25A UL489, adapter can be only used together with ABB Pro M MCB S200 UL489
L1/L2/L3 Litze o. ZLS970 UL 1 144 4822 ZLS970UL 2CCA337020R0001 0.021 1
L1/L2/L3 Litze u. ZLS971 UL 1 144 4839 ZLS971UL 2CCA337021R0001 0.021 1
Adapter 45A UL489, adapter can be only used together with ABB Pro M MCB S200 UL489
L1/L2/L3 Litze o. ZLS972 UL 1 144 4860 ZLS972UL 2CCA337024R0001 0.025 1
L1/L2/L3 Litze u. ZLS973 UL 1 144 4877 ZLS973UL 2CCA337025R0001 0.025 1
Dummy housing
1 144 4556 ZLS964 2CCA180550R0001 0.011 1
—
SMISSLINE TP plug-in system
Universal adapters - 27mm wide Solution for S800
Simple mounting S800 MCB on SMISSLINE TP system with 27mm wide universal adapter.
Assembly to plug-in socket system with universal adapter and S800. Maximum rated current
of outgoing circuits (Inc) max. 50A for S800 with ZLS972X, ZLS973X.
9
S800 1P ZLS97X ZLS965 ZLS965 ZLS97X S800 2P ZLS97X ZLS964 ZLS97X
C US C US C US C US C US
27 mm 27 mm 27 mm
1.5 PLE 1.5 PLE 1.5 PLE
S800 3P ZLS97X ZLS964 ZLS97X ZLS97X ZLS965 S800 4P ZLS97X ZLS964 ZLS97X ZLS965 ZLS97X ZLS965 ZLS97X
C US C US C US C US C US C US C US C US C US
E210-SPV
E210-SPV
E210-SPV
E210-SPV
E210-SPV
E210-SPV
ZLS E210- ZLS ZLS ZLS ZLS ZLS ZLS
In max. In max. In max. In max. In max. In max. In max.
L1 - L2 - L3 SPV L1 - L2 - L3 L1 - L2 - L3 L1 - L2 - L3 L1 - L2 - L3 L1 - L2 - L3 L1 - L2 - L3
—
SMISSLINE TP plug-in system
Busbars 40 A and 125 A
Planning for the incorporation of feeder block and spare places should be taken into account.
The total lengths given above were calculated taking socket spacings and tolerances into account.
For this reason, the indicated busbar length is not necessarily a multiple of 18 mm (1 Module).
9/61
—
SMISSLINE TP plug-in system
Technical data according to IEC/EN 61439-6
Power Bar System 250 A
Busbar system touch proof:
Use only for wall mounted application (horizontal or vertical).
When installed correctly the requirements of EN/IEC 61439-2 are met.
Number of poles: 6 to 110
3p+N / 2 additional bars PE+N
Rated operational voltage (Ue): 690 VAC, 1000 VDC
(400 VAC, 250 VDC when used for load-free snap on and off under power)
Rated insulation voltage (Ui) Main circuit: 690 VAC, 1000 VDC
Rated insulation voltage (Ui) Auxilary circuit: 415 VAC
IP Code: IP20B
Mounting position: horizontal or vertical, direct mounting or mounting on DIN rail
acc. to EN 60715 35 mm
Pollution degree: 3 (690 V a.c.) 2 (1000 V d.c.)
Rated impulse voltage (Uimp): 8 kV Main circuit; 6 KV Auxiliary circuit
Rated current of the assembly (InA) : max. 250 A side feeding
Rated current of a circuit (Inc) : Main circuit: Max. 100 A
9
Rated current of Auxiliary circuit: 40 A
Rated short-time withstand current (Icw): 15kA/100 ms Main circuit
4 kA / 50 ms Auxiliary circuit
Rated peak withstand current Main circuit (Ipk): Main circuit: 30 kA
Rated peak withstand current Auxilary circuit (Ipk): 6 kA
Rated frequency (f): 50/60 Hz
Rated conditional short-circuit current (Icc): see table below
Ambient air temperature: max. 60°C
Size of CU bars 3P+N+PE: 3 x25 mm (75 mm2)
Size of CU auxiliary bars La Lb: 2 x 5 mm (10 mm2)
Rated Voltage (Ue) Rated conditional Incoming current of main Short circuit protection device
short-circuit current (Icc) busbars (L1, L2, L3, N) (SCPD)
Fuse MCCB
415 V 100 kA 250 A NH1 gG 690 V/250 A ABB
Tmax T4/XT4 250 A
690 V 25 kA 250 A NH1 gG 690 V/250 A ABB
Tmax T4/XT4 250 A
Incoming current
of auxiliary busbars (La Lb)
25 kA 40 A NH00 gG 415 V/40 A ABB Type S800(240/415VAC)
9/62 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Busbar system 250 A
—
SMISSLINE TP plug-in system
Starter 3L
Power Bar System 250 A
9
Starter Pack 3L PLE 42 ZLSP950E42-3L 2CCF212206A0001 148 8369 1 42PLE-3L 2421
Starter Pack 3L PLE 44 ZLSP950E44-3L 2CCF212207A0001 148 8383 1 44PLE-3L 2528
Starter Pack 3L PLE 46 ZLSP950E46-3L 2CCF212208A0001 148 8406 1 46PLE-3L 2635
Starter Pack 3L PLE 48 ZLSP950E48-3L 2CCF212209A0001 148 8420 1 48PLE-3L 2742
Starter Pack 3L PLE 50 ZLSP950E50-3L 2CCF212210A0001 148 8444 1 50PLE-3L 2861
Starter Pack 3L PLE 52 ZLSP950E52-3L 2CCF212211A0001 148 8468 1 52PLE-3L 2968
Starter Pack 3L PLE 54 ZLSP950E54-3L 2CCF212212A0001 148 8482 1 54PLE-3L 3075
Starter Pack 3L PLE 56 ZLSP950E56-3L 2CCF212213A0001 148 8505 1 56PLE-3L 3182
Starter Pack 3L PLE 58 ZLSP950E58-3L 2CCF212214A0001 148 8529 1 58PLE-3L 3301
Starter Pack 3L PLE 60 ZLSP950E60-3L 2CCF212215A0001 148 8543 1 60PLE-3L 3408
Starter Pack 3L PLE 62 ZLSP950E62-3L 2CCF212216A0001 148 8567 1 62PLE-3L 3515
Starter Pack 3L PLE 64 ZLSP950E64-3L 2CCF212217A0001 148 8581 1 64PLE-3L 3622
Starter Pack 3L PLE 66 ZLSP950E66-3L 2CCF212218A0001 148 8604 1 66PLE-3L 3741
Starter Pack 3L PLE 68 ZLSP950E68-3L 2CCF212219A0001 148 8628 1 68PLE-3L 3848
Starter Pack 3L PLE 70 ZLSP950E70-3L 2CCF212220A0001 148 8642 1 70PLE-3L 3955
Starter Pack 3L PLE 72 ZLSP950E72-3L 2CCF212221A0001 148 8666 1 72PLE-3L 4062
Starter Pack 3L PLE 74 ZLSP950E74-3L 2CCF212222A0001 148 8680 1 74PLE-3L 4180
Starter Pack 3L PLE 76 ZLSP950E76-3L 2CCF212223A0001 148 8703 1 76PLE-3L 4288
Starter Pack 3L PLE 78 ZLSP950E78-3L 2CCF212224A0001 148 8727 1 78PLE-3L 4395
Starter Pack 3L PLE 80 ZLSP950E80-3L 2CCF212225A0001 148 8741 1 80PLE-3L 4502
Starter Pack 3L PLE 82 ZLSP950E82-3L 2CCF212226A0001 148 8765 1 82PLE-3L 4620
Starter Pack 3L PLE 84 ZLSP950E84-3L 2CCF212227A0001 148 8789 1 84PLE-3L 4728
Starter Pack 3L PLE 86 ZLSP950E86-3L 2CCF212228A0001 148 8802 1 86PLE-3L 4835
Starter Pack 3L PLE 88 ZLSP950E88-3L 2CCF212229A0001 148 8826 1 88PLE-3L 4942
Starter Pack 3L PLE 90 ZLSP950E90-3L 2CCF212230A0001 148 8840 1 90PLE-3L 5060
Starter Pack 3L PLE 92 ZLSP950E92-3L 2CCF212231A0001 148 8864 1 92PLE-3L 5167
Starter Pack 3L PLE 94 ZLSP950E94-3L 2CCF212232A0001 148 8888 1 94PLE-3L 5275
Starter Pack 3L PLE 96 ZLSP950E96-3L 2CCF212233A0001 148 8901 1 96PLE-3L 5382
Starter Pack 3L PLE 98 ZLSP950E98-3L 2CCF212234A0001 148 8925 1 98PLE-3L 5500
Starter Pack 3L PLE 100 ZLSP950E100-3L 2CCF212235A0001 148 8949 1 100PLE-3L 5607
Starter Pack 3L PLE 102 ZLSP950E102-3L 2CCF212236A0001 148 8963 1 102PLE-3L 5715
Starter Pack 3L PLE 104 ZLSP950E104-3L 2CCF212237A0001 148 8987 1 104PLE-3L 5822
Starter Pack 3L PLE 106 ZLSP950E106-3L 2CCF212238A0001 148 9007 1 106PLE-3L 5940
Starter Pack 3L PLE 108 ZLSP950E108-3L 2CCF212239A0001 148 9021 1 108PLE-3L 6047
Starter Pack 3L PLE 110 ZLSP950E110-3L 2CCF212240A0001 148 9045 1 110PLE-3L 6121
9/64 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Starter 3LN
Power Bar System 250 A
Starter Pack 3L: L1, L2, L3, N included socket end piece
Solutions Type ABB EAN number Pack Moduls Weight
available name IT number 761 227 unit (1 PLE 18mm) in grams
Starter Pack 3LN PLE 30 ZLSP950E30-3LN 2CCF212300A0001 148 9069 1 30PLE-3LN 2122
Starter Pack 3LN PLE 32 ZLSP950E32-3LN 2CCF212301A0001 148 9083 1 32PLE-3LN 2253
Starter Pack 3LN PLE 34 ZLSP950E34-3LN 2CCF212302A0001 148 9106 1 34PLE-3LN 2396
Starter Pack 3LN PLE 36 ZLSP950E36-3LN 2CCF212303A0001 148 9120 1 36PLE-3LN 2527
Starter Pack 3LN PLE 38 ZLSP950E38-3LN 2CCF212304A0001 148 9144 1 38PLE-3LN 2659
Starter Pack 3LN PLE 40 ZLSP950E40-3LN 2CCF212305A0001 148 9168 1 40PLE-3LN 2791
9
Starter Pack 3LN PLE 42 ZLSP950E42-3LN 2CCF212306A0001 148 9182 1 42PLE-3LN 2933
Starter Pack 3LN PLE 44 ZLSP950E44-3LN 2CCF212307A0001 148 9205 1 44PLE-3LN 3065
Starter Pack 3LN PLE 46 ZLSP950E46-3LN 2CCF212308A0001 148 9229 1 46PLE-3LN 3197
Starter Pack 3LN PLE 48 ZLSP950E48-3LN 2CCF212309A0001 148 9243 1 48PLE-3LN 3328
Starter Pack 3LN PLE 50 ZLSP950E50-3LN 2CCF212310A0001 148 9267 1 50PLE-3LN 3471
Starter Pack 3LN PLE 52 ZLSP950E52-3LN 2CCF212311A0001 148 9281 1 52PLE-3LN 3603
Starter Pack 3LN PLE 54 ZLSP950E54-3LN 2CCF212312A0001 148 9304 1 54PLE-3LN 3734
Starter Pack 3LN PLE 56 ZLSP950E56-3LN 2CCF212313A0001 148 9328 1 56PLE-3LN 3866
Starter Pack 3LN PLE 58 ZLSP950E58-3LN 2CCF212314A0001 148 9342 1 58PLE-3LN 4008
Starter Pack 3LN PLE 60 ZLSP950E60-3LN 2CCF212315A0001 148 9366 1 60PLE-3LN 4140
Starter Pack 3LN PLE 62 ZLSP950E62-3LN 2CCF212316A0001 148 9380 1 62PLE-3LN 4272
Starter Pack 3LN PLE 64 ZLSP950E64-3LN 2CCF212317A0001 148 9403 1 64PLE-3LN 4403
Starter Pack 3LN PLE 66 ZLSP950E66-3LN 2CCF212318A0001 148 9427 1 66PLE-3LN 4546
Starter Pack 3LN PLE 68 ZLSP950E68-3LN 2CCF212319A0001 148 9441 1 68PLE-3LN 4678
Starter Pack 3LN PLE 70 ZLSP950E70-3LN 2CCF212320A0001 148 9465 1 70PLE-3LN 4809
Starter Pack 3LN PLE 72 ZLSP950E72-3LN 2CCF212321A0001 148 9489 1 72PLE-3LN 4941
Starter Pack 3LN PLE 74 ZLSP950E74-3LN 2CCF212322A0001 148 9502 1 74PLE-3LN 5084
Starter Pack 3LN PLE 76 ZLSP950E76-3LN 2CCF212323A0001 148 9526 1 76PLE-3LN 5215
Starter Pack 3LN PLE 78 ZLSP950E78-3LN 2CCF212324A0001 148 9540 1 78PLE-3LN 5347
Starter Pack 3LN PLE 80 ZLSP950E80-3LN 2CCF212325A0001 148 9564 1 80PLE-3LN 5478
Starter Pack 3LN PLE 82 ZLSP950E82-3LN 2CCF212326A0001 148 9588 1 82PLE-3LN 5621
Starter Pack 3LN PLE 84 ZLSP950E84-3LN 2CCF212327A0001 148 9601 1 84PLE-3LN 5753
Starter Pack 3LN PLE 86 ZLSP950E86-3LN 2CCF212328A0001 148 9625 1 86PLE-3LN 5884
Starter Pack 3LN PLE 88 ZLSP950E88-3LN 2CCF212329A0001 148 9649 1 88PLE-3LN 6016
Starter Pack 3LN PLE 90 ZLSP950E90-3LN 2CCF212330A0001 148 9663 1 90PLE-3LN 6159
Starter Pack 3LN PLE 92 ZLSP950E92-3LN 2CCF212331A0001 148 9687 1 92PLE-3LN 6290
Starter Pack 3LN PLE 94 ZLSP950E94-3LN 2CCF212332A0001 148 9700 1 94PLE-3LN 6422
Starter Pack 3LN PLE 96 ZLSP950E96-3LN 2CCF212333A0001 148 9724 1 96PLE-3LN 6554
Starter Pack 3LN PLE 98 ZLSP950E98-3LN 2CCF212334A0001 148 9748 1 98PLE-3LN 6696
Starter Pack 3LN PLE 100 ZLSP950E100-3LN 2CCF212335A0001 148 9762 1 100PLE-3LN 6828
Starter Pack 3LN PLE 102 ZLSP950E102-3LN 2CCF212336A0001 148 9786 1 102PLE-3LN 6959
Starter Pack 3LN PLE 104 ZLSP950E104-3LN 2CCF212337A0001 148 9809 1 104PLE-3LN 7091
Starter Pack 3LN PLE 106 ZLSP950E106-3LN 2CCF212338A0001 148 9823 1 106PLE-3LN 7234
Starter Pack 3LN PLE 108 ZLSP950E108-3LN 2CCF212339A0001 148 9847 1 108PLE-3LN 7365
Starter Pack 3LN PLE 110 ZLSP950E110-3LN 2CCF212340A0001 148 9861 1 110PLE-3LN 7463
9/65
—
SMISSLINE TP plug-in system
Starter 3LN LA LB
Power Bar System 250 A
Starter Pack 3L: L1, L2, L3,N, LA, LB included socket end piece
Solutions Type ABB EAN number Pack Moduls Weight
available name IT number 761 227 unit (1 PLE 18mm) in grams
Starter Pack 3LN LA LB PLE 30 ZLSP950E30-3LNLALB 2CCF212400A0001 148 9885 1 30PLE-3LNLALB 2480
Starter Pack 3LN LA LB PLE 32 ZLSP950E32-3LNLALB 2CCF212401A0001 148 9908 1 32PLE-3LNLALB 2611
Starter Pack 3LN LA LB PLE 34 ZLSP950E34-3LNLALB 2CCF212402A0001 148 9922 1 34PLE-3LNLALB 2754
Starter Pack 3LN LA LB PLE 36 ZLSP950E36-3LNLALB 2CCF212403A0001 148 9946 1 36PLE-3LNLALB 2885
Starter Pack 3LN LA LB PLE 38 ZLSP950E38-3LNLALB 2CCF212404A0001 148 9960 1 38PLE-3LNLALB 3017
Starter Pack 3LN LA LB PLE 40 ZLSP950E40-3LNLALB 2CCF212405A0001 148 9984 1 40PLE-3LNLALB 3149
9
Starter Pack 3LN LA LB PLE 42 ZLSP950E42-3LNLALB 2CCF212406A0001 149 0003 1 42PLE-3LNLALB 3291
Starter Pack 3LN LA LB PLE 44 ZLSP950E44-3LNLALB 2CCF212407A0001 149 0027 1 44PLE-3LNLALB 3423
Starter Pack 3LN LA LB PLE 46 ZLSP950E46-3LNLALB 2CCF212408A0001 149 0041 1 46PLE-3LNLALB 3555
Starter Pack 3LN LA LB PLE 48 ZLSP950E48-3LNLALB 2CCF212409A0001 149 0065 1 48PLE-3LNLALB 3686
Starter Pack 3LN LA LB PLE 50 ZLSP950E50-3LNLALB 2CCF212410A0001 149 0089 1 50PLE-3LNLALB 3829
Starter Pack 3LN LA LB PLE 52 ZLSP950E52-3LNLALB 2CCF212411A0001 149 0102 1 52PLE-3LNLALB 3961
Starter Pack 3LN LA LB PLE 54 ZLSP950E54-3LNLALB 2CCF212412A0001 149 0126 1 54PLE-3LNLALB 4092
Starter Pack 3LN LA LB PLE 56 ZLSP950E56-3LNLALB 2CCF212413A0001 149 0140 1 56PLE-3LNLALB 4224
Starter Pack 3LN LA LB PLE 58 ZLSP950E58-3LNLALB 2CCF212414A0001 149 0164 1 58PLE-3LNLALB 4366
Starter Pack 3LN LA LB PLE 60 ZLSP950E60-3LNLALB 2CCF212415A0001 149 0188 1 60PLE-3LNLALB 4498
Starter Pack 3LN LA LB PLE 62 ZLSP950E62-3LNLALB 2CCF212416A0001 149 0201 1 62PLE-3LNLALB 4630
Starter Pack 3LN LA LB PLE 64 ZLSP950E64-3LNLALB 2CCF212417A0001 149 0225 1 64PLE-3LNLALB 4761
Starter Pack 3LN LA LB PLE 66 ZLSP950E66-3LNLALB 2CCF212418A0001 149 0249 1 66PLE-3LNLALB 4904
Starter Pack 3LN LA LB PLE 68 ZLSP950E68-3LNLALB 2CCF212419A0001 149 0263 1 68PLE-3LNLALB 5036
Starter Pack 3LN LA LB PLE 70 ZLSP950E70-3LNLALB 2CCF212420A0001 149 0287 1 70PLE-3LNLALB 5167
Starter Pack 3LN LA LB PLE 72 ZLSP950E72-3LNLALB 2CCF212421A0001 149 0300 1 72PLE-3LNLALB 5299
Starter Pack 3LN LA LB PLE 74 ZLSP950E74-3LNLALB 2CCF212422A0001 149 0324 1 74PLE-3LNLALB 5442
Starter Pack 3LN LA LB PLE 76 ZLSP950E76-3LNLALB 2CCF212423A0001 149 0348 1 76PLE-3LNLALB 5573
Starter Pack 3LN LA LB PLE 78 ZLSP950E78-3LNLALB 2CCF212424A0001 149 0362 1 78PLE-3LNLALB 5705
Starter Pack 3LN LA LB PLE 80 ZLSP950E80-3LNLALB 2CCF212425A0001 149 0386 1 80PLE-3LNLALB 5836
Starter Pack 3LN LA LB PLE 82 ZLSP950E82-3LNLALB 2CCF212426A0001 149 0409 1 82PLE-3LNLALB 5979
Starter Pack 3LN LA LB PLE 84 ZLSP950E84-3LNLALB 2CCF212427A0001 149 0423 1 84PLE-3LNLALB 6111
Starter Pack 3LN LA LB PLE 86 ZLSP950E86-3LNLALB 2CCF212428A0001 149 0447 1 86PLE-3LNLALB 6242
Starter Pack 3LN LA LB PLE 88 ZLSP950E88-3LNLALB 2CCF212429A0001 149 0461 1 88PLE-3LNLALB 6374
Starter Pack 3LN LA LB PLE 90 ZLSP950E90-3LNLALB 2CCF212430A0001 149 0485 1 90PLE-3LNLALB 6517
Starter Pack 3LN LA LB PLE 92 ZLSP950E92-3LNLALB 2CCF212431A0001 149 0508 1 92PLE-3LNLALB 6648
Starter Pack 3LN LA LB PLE 94 ZLSP950E94-3LNLALB 2CCF212432A0001 149 0522 1 94PLE-3LNLALB 6780
Starter Pack 3LN LA LB PLE 96 ZLSP950E96-3LNLALB 2CCF212433A0001 149 0546 1 96PLE-3LNLALB 6912
Starter Pack 3LN LA LB PLE 98 ZLSP950E98-3LNLALB 2CCF212434A0001 149 0560 1 98PLE-3LNLALB 7054
Starter Pack 3LN LA LB PLE 100 ZLSP950E100-3LNLALB 2CCF212435A0001 149 0584 1 100PLE-3LNLALB 7186
Starter Pack 3LN LA LB PLE 102 ZLSP950E102-3LNLALB 2CCF212436A0001 149 0607 1 102PLE-3LNLALB 7317
Starter Pack 3LN LA LB PLE 104 ZLSP950E104-3LNLALB 2CCF212437A0001 149 0621 1 104PLE-3LNLALB 7449
Starter Pack 3LN LA LB PLE 106 ZLSP950E106-3LNLALB 2CCF212438A0001 149 0645 1 106PLE-3LNLALB 7592
Starter Pack 3LN LA LB PLE 108 ZLSP950E108-3LNLALB 2CCF212439A0001 149 0669 1 108PLE-3LNLALB 7723
Starter Pack 3LN LA LB PLE 110 ZLSP950E110-3LNLALB 2CCF212440A0001 149 0683 1 110PLE-3LNLALB 7821
9/66 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Sockets and Incoming components
Power Bar System 250 A
Socket base
Description Type ABB EAN number Pack Moduls Weight
name IT number 761 227 unit (1 PLE in
18mm) grams
ZLSP920 End piece main socket ZLSP906 ZLSP920 2CCF212082A0001 148 7386 1 2 103
or ZLSP908
End piece additional socket ZLSP921 2CCF212085A0001 148 7409 1 2 54
ZLSP926 or ZLSP928
—
SMISSLINE TP plug-in system
Incoming bolt-on solution
Power Bar System 250 A
Incoming bolt-on solution M8 50 mm2 up to 150 mm or 4/0AWG for UL
This solution is only possible to mount on a ZLSP908 (not on ZLSP906, ZLS906, ZLS908).
9
Incoming terminal block 1506193 ZLSP935-8PE 2CCG000043R0001 0.178 1
additional socket PE left
250A 8PLE
Incoming terminal block 1506223 ZLSP935-8NPE-R 2CCG000046R0001 0.268 1
additional socket N PE right
250A 8PLE
Incoming terminal block 1506230 ZLSP935-8PE-R 2CCG000047R0001 0.178 1
additional socket PE right
250A 8PLE
Covers for ZLSP934
Cover for Incoming terminal 1506278 ZLSP963 2CCG000051R0001 0.018 1
block 250A
Cover an connection N-N 1506261 ZLSP963N-N 2CCG000050R0001 0.074 1
250A
Cover for connection with 1507541 ZLSP964 2CCG000207R0001 0.034 4
the cables on one terminal
9/68 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Additonal socket
Power Bar System 250 A
Additional socket
The additional socket can easily be fitted onto the socket base to accomodate the external N
and/or PE busbars. This enables neutral connections to be made where single-pole minia-
ture circuit breakers are used with unswitched neutral. Neutral terminals are clipped onto
the additional socket and can be used as detachable neutral connections. One N busbar and/
or one PE busbar can be fitted. Each socket base can be equipped with an additional socket.
Busbar insulator
Type ABB IT number EAN number Pack- Module Weight
name 761 227 aging in
unit grams
Busbar cover
Type ABB IT number EAN number Pack- Module Weight
name 761 227 aging in
unit grams
Din rail clip ZLSP926 and ZLSP937 2CCA212012R0001 498 306 Bag 18
ZLSP928. This item is need if the of 5
additional socket will be mounted
on a DIN rail. 1 pcs. every 30 cm.
9/69
—
SMISSLINE TP plug-in system
Busbars Power Bar System 250 A and 40 A
9
ZLSP1250E54 2CCF212100M0054 148 7669 6 1 1 54 659 968 ZLS203E54 2CCF800241R0001 001 7904
ZLSP1250E56 2CCF212100M0056 148 7683 7 – 1 56 683 1004 ZLS203E56 2CCF800242R0001 001 7928
ZLSP1250E58 2CCF212100M0058 148 7706 5 3 1 58 708 1040 ZLS203E58 2CCF800243R0001 001 7942
ZLSP1250E60 2CCF212100M0060 148 7720 6 2 1 60 732 1076 ZLS203E60 2CCF800244R0001 001 7973
ZLSP1250E62 2CCF212100M0062 148 7744 7 1 1 62 757 1112 ZLS203E62 2CCF800245R0001 001 7997
ZLSP1250E64 2CCF212100M0064 148 7768 8 – 1 64 781 1148 ZLS203E64 2CCF800246R0001 001 8017
ZLSP1250E66 2CCF212100M0066 148 7782 6 3 1 66 806 1184 ZLS203E66 2CCF800247R0001 001 8031
ZLSP1250E68 2CCF212100M0068 148 7805 7 2 1 68 830 1220 ZLS203E68 2CCF800248R0001 001 8055
ZLSP1250E70 2CCF212100M0070 148 7829 8 1 1 70 854 1256 ZLS203E70 2CCF800249R0001 001 8079
ZLSP1250E72 2CCF212100M0072 148 7843 9 – 1 72 879 1292 ZLS203E72 2CCF800250R0001 001 8093
ZLSP1250E74 2CCF212100M0074 148 7867 7 3 1 74 903 1328 ZLS203E74 2CCF800251R0001 001 8116
ZLSP1250E76 2CCF212100M0076 148 7881 8 2 1 76 928 1364 ZLS203E76 2CCF800252R0001 001 8130
ZLSP1250E78 2CCF212100M0078 148 7904 9 1 1 78 952 1400 ZLS203E78 2CCF800253R0001 001 8154
ZLSP1250E80 2CCF212100M0080 148 7928 10 – 1 80 976 1436 ZLS203E80 2CCF800254R0001 001 8185
ZLSP1250E82 2CCF212100M0082 148 7942 8 3 1 82 1001 1472 ZLS203E82 2CCF800255R0001 001 8208
ZLSP1250E84 2CCF212100M0084 148 7966 9 2 1 84 1025 1508 ZLS203E84 2CCF800256R0001 001 8222
ZLSP1250E86 2CCF212100M0086 148 7980 10 1 1 86 1050 1544 ZLS203E86 2CCF800257R0001 001 8246
ZLSP1250E88 2CCF212100M0088 148 8000 11 – 1 88 1074 1580 ZLS203E88 2CCF800258R0001 001 8260
ZLSP1250E90 2CCF212100M0090 148 8024 9 3 1 90 1098 1616 ZLS203E90 2CCF800259R0001 001 8284
ZLSP1250E92 2CCF212100M0092 148 8048 10 2 1 92 1123 1652 ZLS203E92 2CCF800260R0001 001 8307
ZLSP1250E94 2CCF212100M0094 148 8062 11 1 1 94 1147 1688 ZLS203E94 2CCF800261R0001 001 8321
ZLSP1250E96 2CCF212100M0096 148 8086 12 – 1 96 1172 1724 ZLS203E96 2CCF800262R0001 001 8345
ZLSP1250E98 2CCF212100M0098 148 8109 10 3 1 98 1196 1760 ZLS203E98 2CCF800263R0001 001 8369
ZLSP1250E100 2CCF212100M0100 148 8123 11 2 1 100 1220 1796 ZLS203E100 2CCF800264R0001 001 7195
ZLSP1250E102 2CCF212100M0102 148 8147 12 1 1 102 1245 1832 ZLS203E102 2CCF800265R0001 001 7218
ZLSP1250E104 2CCF212100M0104 148 8161 13 – 1 104 1269 1868 ZLS203E104 2CCF800266R0001 001 7232
ZLSP1250E106 2CCF212100M0106 148 8185 11 3 1 106 1294 1904 ZLS203E106 2CCF800267R0001 001 7256
ZLSP1250E108 2CCF212100M0108 148 8208 12 2 1 108 1318 1940 ZLS203E108 2CCF800268R0001 001 7270
Planning for the incorporation of feeder block and spare places should be taken into account.
The total lengths given above were calculated taking socket spacings and tolerances into account.
For this reason, the indicated busbar length is not necessarily a multiple of 18 mm (1 Module).
9/70 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
One system with many options
SMISSLINE TP protective devices with plug-in technology – SMISSLINE TP and ABB STRIEBEL & JOHN –
the individual way in switchgear technology the cabinet system at a glance:
Five modern protective devices in the same design are • Flexible and modular
simply plugged onto a busbar system. The complex feed-in • Freedom in concept and arrangement
and connection work is already done. In addition to this time • Time saved during planning and execution
and cost savings, it is crucial to be able to quickly and easily • Quick adaptation when expanding
replace equipment. Third-party devices can be integrated • Allows for the load-free connection and disconnection of
into the busbar system by using adapters. The system was devices and components under voltage without the need
developed for commercial and industrial switchgear for additional personal protective equipment to guard
technology. Installation and wiring times can be greatly against electrical hazards
reduced by using the directly attachable system. • Coordinated product components
• SMISSLINE TP modules can be combined with other
Together with the ABB STRIEBEL & JOHN switchgear system, ABB STRIEIBEL & JOHN distribution panels and modules
optimum space utilization, easy changes and expansion of
the switch cabinet and its installations can be achieved Small cause, large effect
thanks to horizontal or vertical installation options. The As the world's first pluggable socket system, SMISSLINE TP
9
individual components are coordinated with each other, allows devices and components to be snapped on and off,
such as the length of the plug-in socket and the modular load-free and under voltage, without having to take
components of the switch cabinets. Of course, mixed additional personal protective measures. It opens up to
installation options of conventional modular devices can a completely new prospects when it comes to installation,
also easily be realized, such as pro M Compact. The operation and flexibility.
configured ABB STRIEBEL & JOHN expansion products make
this possible.
—
SMISSLINE TP plug-in system
One system with many options
9
—
01
The outlet wiring is done directly
on the installed devices. The N and
PE terminals are assigned to the
devices accordingly. The outlet
cables are affixed in a mesh cable
tray neatly and clearly arranged.
—
02
A cabinet equipped with
modules for accommodating
SMISSLINE TP devices with
third-party device adapters
and pro M modular devices.
— —
01 02
9/72 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
CombiLine modules view
Horizontal modules are suitable for mounting on WR or Vertical modules are suitable for mounting in cabinets from
EDF profiles. From cabinet depth of 215 mm. The WR or a depth of 275 mm. The mounting frame must be ordered
EDF mounting frame must be ordered separately. separately. Cable laying grid is included for cable fixing.
With DIN rail for PE/N disconnect terminals.
—
SMISSLINE TP 125 A interior expansion with CombiLine
Options for assembly in an enclosure
For a horizontal device arrangement, the DIN rail can be set For a vertical device arrangement, the existing cover holders
in conjunction with mounting adapters. The Busbar systems are replaced with cover holders ED137P4 with spacers
cannot be through-connected from one panel to the next. ED135P4 in conjunction with mounting adapters. In addition,
The DIN rail is mounted to a 2-stage bracket (in front upon a cover raising frame is required, so that there is more space
delivery). The front position is for the plug-in socket under the cover. All devices using mounting adapters are to
assembly. The SMISSLINE TP devices will directly be be arranged under a separate cover. Cable lying grids are
mounted. The back position is for mounting the socket installed for modules with a vertical device arrangement in
bases for devices with universal adapters. order to attach the lines. The DIN rails are designed to be
equipped with the SMISSLINE TP socket base rows. It is also
possible to connect the SMISSLINE TP additional socket
(N/PE terminals).
9
Horizontal device arrangement Vertical device arrangement
—
SMISSLINE TP 125 A interior expansion with CombiLine
For horizontal and vertical device arrangement
—
SMISSLINE TP Power Bar 250 A interior expansion with CombiLine
For horizontal and vertical device arrangement
9
450 3 750 3 x 36 ● ● 215 MBC303HS 2CPX042158R9999 MC303HS 2CPX042135R9999
4 600 2 500 4 x 22 ● ● 215 MBC204HS 2CPX042159R9999 MC204HS 2CPX042136R9999
600 3 750 4 x 36 ● ● 215 MBC304HS 2CPX042160R9999 MC304HS 2CPX042137R9999
5 750 2 500 5 x 22 ● ● 215 MBC205HS 2CPX042161R9999 MC205HS 2CPX042138R9999
750 3 750 5 x 36 ● ● 215 MBC305HS 2CPX042162R9999 MC305HS 2CPX042139R9999
—
SMISSLINE TP plug-in system
Cable laying grids, DIN rails, fixing brackets
ZW470
ZW359
ZX399
ZW592
9/7 7
—
SMISSLINE TP plug-in system
Cover holders, panel connectors, raising frames
ED137P4
ED138P12
9
ED135P4
ED50P12
External dimensions (H x W)
450 x 250 mm 1 ED213 2CPX062783R9999
600 x 250 mm 1 ED214 2CPX062784R9999
ED213 750 x 250 mm 1 ED215 2CPX062785R9999
450 x 500 mm 1 ED223 2CPX062788R9999
600 x 500 mm 1 ED224 2CPX062789R9999
750 x 500 mm 1 ED225 2CPX062790R9999
450 x 750 mm 1 ED233 2CPX062793R9999
600 x 750 mm 1 ED234 2CPX062794R9999
750 x 750 mm 1 ED235 2CPX062795R9999
9/78 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Plastic cover horizontal
External dimensions (H x W)
300 x 500 mm M(B)C202HS 1 AS22H 2CPX062764R9999
450 x 500 mm M(B)C203HS 1 AS23H 2CPX062765R9999
600 x 500 mm M(B)C204HS 1 AS24H 2CPX062766R9999
750 x 500 mm M(B)C205HS 1 AS25H 2CPX062767R9999
AS22H
External dimensions (H x W)
300 x 750 mm M(B)C302HS 1 AS32H 2CPX062768R9999
450 x 750 mm M(B)C303HS 1 AS33H 2CPX062769R9999
600 x 750 mm M(B)C304HS 1 AS34H 2CPX062770R9999
750 x 750 mm M(B)C305HS 1 AS35H 2CPX062771R9999
AS32H
9/79
—
SMISSLINE TP plug-in system
Plastic cover vertical
External dimensions (H x W)
450 x 250 mm M(B)C103VS 1 AS13V 2CPX062772R9999
600 x 250 mm M(B)C104VS 1 AS14V 2CPX062773R9999
750 x 250 mm M(B)C105VS 1 AS15V 2CPX062774R9999
AS13V
External dimensions (H x W)
450 x 500 mm M(B)C203VS 1 AS23V 2CPX062775R9999
600 x 500 mm M(B)C204VS 1 AS24V 2CPX062776R9999
9
750 x 500 mm M(B)C205VS 1 AS25V 2CPX062777R9999
AS23V
Plastic cover vertical
With device slot, 3 panel wide
External dimensions (H x W)
750 x 750 mm M(B)C305VS 1 AS35V 2CPX062796R9999
AS35V
9/80 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Socket calculation with e-Design and Panel Design Configurator
Advantages at a glance:
9
Information about:
• Incoming and outgoing current
• Control and display of the units, the current and the
power loss
• Technical specifications of the devices, including
price calculation (in StriePlan)
• Print or export (in StriePlan) of BOMs, design
drawings or tender texts
Accessories dialog
The combination of devices and additional
components (e.g.: auxiliary and signal contacts)
is comprehensively supported
• Automatic insertion of component combinations
• Automatic component selection for right/left
positioning
—
SMISSLINE TP plug-in system
Comparison of starting package with plug-in socket in individual parts
9
Solution of plug-in socket in individual parts
You can assemble plug-in sockets, busbars and socket end The busbars can be ordered in the length of 1979 mm and
pieces on your own from the individual components. shortened accordingly. It is also possible to order busbars
Plug-in sockets with 8 units (144 mm) and 6 units (108 mm) from ABB already cut to length.
can be selected and assembled in any number up to 110 PLE.
9/82 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
SMISSLINE TP plug-in system
Assignment of CombiLine modules
Modules for cabinets Modules for cabinets from Grid units Socket base length
from a cabinet a cabinet depth of 275 mm
depth of 215 mm
CombiLine
Combination sets type mounted CombiLine flatpack GU SU
250 mm
1 x ED103VS 1 x MC103VS 1 x MBC103VS 3 RE 22 PLE
450 mm
Vertical modules cannot be mounted directly on central support rails and horizontal
cross members.
9/83
—
SMISSLINE TP plug-in system
Starter kit or socket base in individual parts
Unit Type Order code Unit Space units Type Order code
1 ZLS905E22-3L 2CCA183102R0001 2 8 ZLS908 2CCA183030R0001
1 6 ZLS906 2CCA183035R0001
1 - ZLS920 (end piece) 2CCA183017R0001
1 ZLS905E22-3LN* 2CCA183103R0001 3/4* - ZLS201E22 2CCF800169R0001
(Copper rail)
9
1 ZLS905E38-3L 2CCA183118R0001 4 8 ZLS908 2CCA183030R0001
1 6 ZLS906 2CCA183035R0001
1 - ZLS920 (end piece) 2CCA183017R0001
1 ZLS905E38-3LN* 2CCA183119R0001 3/4* - ZLS201E46 2CCF800177R0001
(Copper rail)
—
SMISSLINE TP plug-in system
Assignment of CombiLine modules
Modules for cabinets Modules for cabinets from Grid units Socket base length
from a cabinet a cabinet depth of 275 mm
depth of 215 mm
CombiLine CombiLine
Combination sets type mounted Flatpack GU SU
1 x ED203VS 1 x MC203VS 1 x MBC203VS 3 GU 2 x 22 SU
450 mm
Vertical modules cannot be mounted directly on central support rails and horizontal
cross members.
9/85
—
SMISSLINE TP plug-in system
Starter kit or socket base in individual parts
Unit Type Order code Unit Space units Type Order code
2 ZLS905E22-3L 2CCA183102R0001 4 8 ZLS908 2CCA183030R0001
2 6 ZLS906 2CCA183035R0001
2 - ZLS920 (end piece) 2CCA183017R0001
2 ZLS905E22-3LN* 2CCA183103R0001 6/8* - ZLS201E22 (copper rail) 2CCF800165R0001
9
2 ZLS905E38-3L 2CCA183118R0001 8 8 ZLS908 2CCA183030R0001
2 6 ZLS906 2CCA183035R0001
2 - ZLS920 (end piece) 2CCA183017R0001
2 ZLS905E38-3LN* 2CCA183119R0001 6/8* - ZLS201E38 (copper rail) 2CCF800173R0001
—
SMISSLINE TP plug-in system
Assignment of CombiLine modules
Modules for cabinets Modules for cabinets from Grid units Socket base length
from a cabinet a cabinet depth of 215 mm
depth of 215 mm
CombiLine CombiLine
Combination sets type mounted flatpack GU SU
500 mm
– 1 x MC202HS 1 x MBC202HS 2 GU 2 x 22 SU
300 mm
600 mm
750 mm
– 1 x MC302HS 1 x MBC302HS 2 GU 2 x 36 SU
300 mm
—
SMISSLINE TP plug-in system
Starter kit or socket base in individual parts
Unit Type Order code Unit Space units Type Order code
2 ZLS905E22-3L 2CCA183102R0001 4 8 ZLS908 2CCA183030R0001
2 6 ZLS906 2CCA183035R0001
2 - ZLS920 (end piece) 2CCA183017R0001
2 ZLS905E22-3LN* 2CCA183103R0001 6/8* - ZLS201E22 (copper rail) 2CCF800165R0001
9
4 6 ZLS906 2CCA183035R0001
4 ZLS920 (end piece) 2CCA183017R0001
4 ZLS905E22-3LN* 2CCA183103R0001 12/16* ZLS201E22 (copper rail) 2CCF800165R0001
—
SMISSLINE TP plug-in system
Assignment of CombiLine modules
Modules for cabinets Modules for cabinets from Grid units Socket base length
from a cabinet a cabinet depth of 275 mm
depth of 215 mm
CombiLine CombiLine
Combination sets type mounted Flatpack GU SU
1 x ED203VS 1 x MC203VS 1 x MBC203VS 3 GU 2 x 22 SU
450 mm
Vertical modules cannot be mounted directly on central support rails and horizontal
cross members.
9/89
—
SMISSLINE TP plug-in system
Starter kit or socket base in individual parts
Unit Type Order code Unit Space units Type Order code
- - - - - -
- - - -
- - - -
- - - - - -
9
2 ZLSP950E38-3L 2CCF212204A0001 8 8 ZLSP908 2CCF212052A0001
2 6 ZLSP906 2CCF212053A0001
2 - ZLSP920 2CCF212082A0001 socket
2 ZLSP950E38-3LN* 2CCF212304A0001 6/8* - ZLSP1250E38 2CCF212100M0038
—
SMISSLINE TP plug-in system
Assignment of CombiLine modules
Modules for cabinets Modules for cabinets from a Grid units Socket base length
from a cabinet cabinet depth of 215 mm
depth of 215 mm
CombiLine
Combination sets type mounted CombiLine kit GU SU
750 mm
– 1 x MC302HS 1 x MBC302HS 2 GU 2 x 36 SU
300 mm
—
SMISSLINE TP plug-in system
Starter kit or socket base in individual parts
Unit Type Order code Unit Space units Type Order code
2 ZLSP950E36-3L 2CCF212203A0001 6 8 ZLSP908 2CCF212052A0001
4 6 ZLSP906 2CCF212053A0001
2 - ZLSP920 2CCF212082A0001 socket
2 ZLSP950E36-3LN* 2CCF212303A0001 6/8* - ZLSP1250E36 2CCF212100M0036
9
4 ZLSP950E36-3L 2CCF212203A0001 12 8 ZLSP908 2CCF212052A0001
8 6 ZLSP906 2CCF212053A0001
4 - ZLSP920 2CCF212082A0001 socket
4 ZLSP950E36-3LN* 2CCF212303A0001 12/16* - ZLSP1250E36 2CCF212100M0036
—
Electrical installation solutions for buildings
Industrial plugs and sockets
10
For entertainment applications 10/47 B-line10/169
Plugs and sockets 10/49 Plugs10/170
Sockets10/171
Fast & Safe 10/55 Inlets for wall mounting 10/172
Plugs IP44 10/57 Inlets for panel mounting 10/173
Connectors IP44 10/58 Socket outlet for wall mounting 10/175
Inlets IP44 10/59 Socket outlets for panel mounting 10/177
Outlets IP44 10/64
Connector unit 10/178
Plugs IP67 10/68 with mechanical interlock 10/179
Connectors IP67 10/69 with block contactor 10/181
Inlets IP67 10/70 with circuit breaker 10/183
Outlets IP67 10/73
—
Industrial plugs and sockets
Reliable, durable and safe.
Perfect for your application
These products are used for connection of equipment in all kind of
applications where it needs to be possible to connect and disconnect.
ABB industrial plugs and sockets are chosen when safety, reliability
and durability is requested.
10
Durable equipment
prevents time and
cost lost due to
maintenance.
Reliable contacts
prevent stops and
power breaks, which
leads to increased
productivity.
Safe connections
prevent accidents.
10/3
—
Industrial plugs and sockets
IEC 60309-2 “clock”
3P + N + E
> 50 V~ > 50 V~
100...300 Hz >300...500 Hz
> 50 V~ > 50 V~
100...300 Hz >300...500 Hz
> 50 V~ 3P + E
> 50 V~
100...300 Hz >300...500 Hz
220/380 V~,
120/208... 380 V~, 50 Hz 50 Hz
200...250 V~ 380...415 V~
10
144/250 V~ 440 V~, 60 Hz 250/440 V~,
50 and 60 Hz 50 and 60 Hz
50 and 60 Hz 60 Hz
100...130 V~
50 and 60 Hz
100...130 V~
1000 V~
for 63 and 125 A 50 and 60 Hz 57/100...
480...500 V~
50 and 60 Hz 75/130 V~ 2P + E
200...250 V~ 50 and 60 Hz
50 and 60 Hz
480...500 V~ 600...690 V~
50 and 60 Hz 50 and 60 Hz
380...415 V~
50 and 60 Hz
277/480..288/500 V~ 347/600...400/690 V~
50 and 60Hz 50 and 60 Hz
200/346...240/415 V~
50 and 60 Hz
—
Industrial plugs and sockets
A perfect choice
Industrial plugs and sockets are a part of the comprehensive
ABB program of high quality low voltage products for industries,
buildings and OEM´s.
ABB has manufactured industrial plugs and sockets tures while others have a straight forward
for over 60 years. functionality. Perfect for demanding customers.
Long experience of developing and manufacturing
plugs and sockets within ABB has resulted in a wide Perfect productivity
product range of high quality and a robust ergo- The reliability of our plugs and sockets will help
10
nomic design. Covering products up to 125 A and 690 you maintain high up-time in operations. No un-
V, all tested and approved for IEC standards. scheduled or unwanted interruptions, allowing
you a high degree of flexibility.
The design and material used have continuously been
improved to meet the customer’s requirements, and Perfect safety
to take the environmental aspects into consider- Safety is also very important. By choosing ABB´s
ation. plugs and sockets you minimize the risk of short
circuits. You also ensure maximum personal safety
ABB´s industrial plugs and sockets have the solution for anyone nearby or around your equipment.
for products in industrial environments with high de-
mands on safety, durability, reliability and cost sav- Perfect for the job
ing for the end user. Different applications and environments require
different products. To make your choice of prod-
• Safety - tested and approved by third party ucts easier, we have categorized our range into
testing laboratories. four groups. All groups have however one feature
in common - Safety
• Durability - m
aterials used give a high durability in
tough conditions and environments.
• Select Critical & Safe products
• Reliability - high quality contacts ensure reliability. for the highest safety in fixed
installations.
• Cost saving - designed for quick and easy
installation. • Select Tough & Safe products
for best performance in demanding
You will find all you need in ABB´s industrial plugs and heavy-duty applications.
and sockets product range. One supplier for all your
needs and worldwide availability. • Select Easy & Safe products
for adequate functionality and
Perfect performance ergonomic design.
ABB´s plugs and sockets comply with the high quality
standards requested when there is a demand for reli- F FAST • Select Fast & Safe products
ability and safety. Some are made of heavy-duty plas- for the fastest installation.
tics (PBT), others of metal. Some have advanced fea
10/5
10
10/6 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Industrial plugs and sockets
Easy & Safe
— —
Plugs Connectors
—
Inlets
10
For wall mounting, Type BS... For wall mounting, Type EBS...W For panel mounting with unified For panel mounting with unified
16 A...32 A, IP4 4 16 A...32 A, IP67 straight flange, Type ...BU... straight flange, Type EBU...W
16A...32 A, IP4 4 16 A...32 A, IP67
—
Socket outlet
For panel mounting with unified For panel mounting with unified
For wall mounting, Type RS... For wall mounting, Type ERS...W straight flange, Type RU... angled flange, Type RAU...
16A...32 A, IP4 4 16 A...32A, IP67 16 A...32 A, IP4 4 16 A...32A, IP4 4
For panel mounting with minimized For panel mounting with unified
straight flange, Type R... For panel mounting with minimized straight flange, Type ERU...W For wall mounting, Type
16 A...32 A, IP4 4 angled flange, Type RAM... 16 A...32A, IP67 ERT, 16 ...63A, IP44
16 A...32A, IP4 4
10/7
—
Industrial plugs and sockets
Easy & Safe
Our new industrial plugs and sockets complements ABB’s strong low-
voltage offer. These plugs and sockets are part of Easy & Safe. Easy &
Safe is a product range suitable for general use in most applications.
In most installations, industrial plugs and sockets Next generation of IP44 plugs and connectors
are part of the exterior, for that reason it was im- Some features of the new IP67 products are also
portant to have an attractive design. The modern implemented in the IP44 plugs and connectors.
design and the strong ABB brand add value to With the new cable gland we get improved sealing
each installation or OEM equipment. and strain relief, it also functions with a wider
span of cables. We have also implemented the
Protect your contacts with new Easy & Safe IP67 new family design of ABB Industrial plugs and
The biggest addition in this series is the new sockets.
designed products with IP67 ingress protection.
10
IP67 is a protection class that guarantees water Applications
and dust tightness. Although water or dust rarely New Easy & Safe series is an excellent choice in
occurs in some applications, the liquids or dirt most applications where high reliability and
may get into the contacting surfaces during the safety are required. For example
products lifetime, which will affect the contacts
performance. This in turn can lead to overheating, • Data centers
burnt contacts and need of replacing plugs and • Industrial applications
sockets. • Food and beverage industries
Worst case scenario is that fluids or dust reaches the • Infrastructure applications
contact parts, which in turn can lead to accidents • Construction sites
with injuries and damage the connected equipment. • Mines
• Marine applications connection of reefer
Electrical contacts protected against liquids and containers
dirt retains its performance over time. High
contact performance means reliability, reducing For tough applications with specific require-
downtime and lowers maintenance costs. Contact ments for UV resistance, chemical resistance,
parts of ABB’s connectors are manufactured with mechanical resistance, our Tough & Safe series
high precision from solid brass. The innovative is still the best option.
design means that the contacts seem self-cleaning
during connection and disconnection while
keeping the contact area free from arcing.
10/8 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
IP44
16 A. Splashproof
Housing in plastic (PA). Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216EP6
2P+E
3 Grey AC 216EP1 2CMA101943R1000 10 0.11
Green > 50 V~ >300...500 216EP2 2CMA101944R1000
Yellow 100...130 50 and 60 216EP4 2CMA101946R1000
Blue 200...250 216EP6 2CMA101947R1000
Red 380...415 216EP9 2CMA101948R1000
Grey transf 216EP12 2CMA101950R1000
3P+E
4 Grey AC 316EP1 2CMA101951R1000 10 0.16
Green > 50 V~ >300...500 316EP2 2CMA101952R1000
10
3P+N+E
5 Grey AC 416EP1 2CMA101962R1000 10 0.18
Green > 50 V~ >300...500 416EP2 2CMA101963R1000
Red 380...440 50/60 416EP3 2CMA101964R1000
Yellow 100...130 50 and 60 416EP4 2CMA101965R1000
Black 600...690 416EP5 2CMA101966R1000
Red 346...415 416EP6 2CMA101967R1000
Black 480...500 416EP7 2CMA101968R1000
Blue 208...250 416EP9 2CMA101969R1000
Red 440...460 60 416EP11 2CMA101970R1000
A
Dimensions (mm)
C
Type A B C Dmax
216EP... 127 62.5 88.5 14
316EP... 144 74.5 106 17
D max B
416EP... 144 78 106 17
10/9
—
Plugs
IP44
32 A. Splashproof
Housing in plastic (PA). Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432EP6
2P+E
3 Grey AC 232EP1 2CMA101971R1000 10 0.21
Green > 50 V~ >300...500 232EP2 2CMA101972R1000
Yellow 100...130 50 and 60 232EP4 2CMA101974R1000
Blue 200...250 232EP6 2CMA101975R1000
Red 380...415 232EP9 2CMA101976R1000
Grey transf 232EP12 2CMA101978R1000
3P+E
4 Grey AC 332EP1 2CMA101979R1000 10 0.23
Green > 50 V~ >300...500 332EP2 2CMA101980R1000
10
Red 380/440 50/60 332EP3 2CMA101981R1000
Yellow 100...130 50 and 60 332EP4 2CMA101982R1000
Black 600...690 332EP5 2CMA101983R1000
Red 380...415 332EP6 2CMA101984R1000
Black 480...500 332EP7 2CMA101985R1000
Blue 200...250 332EP9 2CMA101986R1000
Green > 50 V~ 100...300 332EP10 2CMA101987R1000
Red 440...460 60 332EP11 2CMA101988R1000
Grey transf 50 and 60 332EP12 2CMA101989R1000
3P+N+E
5 Grey AC 432EP1 2CMA101990R1000 10 0.24
Green > 50 V~ >300...500 432EP2 2CMA101991R1000
Red 380...440 50/60 432EP3 2CMA101992R1000
Yellow 100...130 50 and 60 432EP4 2CMA101993R1000
Black 600...690 432EP5 2CMA101994R1000
Red 346...415 432EP6 2CMA101995R1000
Black 480...500 432EP7 2CMA101996R1000
Blue 208...250 432EP9 2CMA101997R1000
Red 440...460 60 432EP11 2CMA101998R1000
A
Dimensions (mm)
C
Type A B C Dmax
232EP... 167 82.5 121 22
332EP... 167 82.5 121 22
D max B
432EP... 167 87.5 121 22
10/10 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Connectors
IP44
16 A. Splashproof
Housing in plastic (PA). Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216EC6
2P+E
3 Grey AC 216EC1 2CMA101999R1000 10 0.16
Green > 50 V~ >300...500 216EC2 2CMA102000R1000
Yellow 100...130 50 and 60 216EC4 2CMA102002R1000
Blue 200...250 216EC6 2CMA102003R1000
Red 380...415 216EC9 2CMA102004R1000
Grey transf 216EC12 2CMA102006R1000
3P+E
4 Grey AC 316EC1 2CMA102007R1000 10 0.21
Green > 50 V~ >300...500 316EC2 2CMA102008R1000
10
3P+N+E
5 Grey AC 416EC1 2CMA102018R1000 10 0.23
Green > 50 V~ >300...500 416EC2 2CMA102019R1000
Red 380...440 50/60 416EC3 2CMA102020R1000
Yellow 100...130 50 and 60 416EC4 2CMA102021R1000
Black 600...690 416EC5 2CMA102022R1000
Red 346...415 416EC6 2CMA102023R1000
Black 480...500 416EC7 2CMA102024R1000
Blue 208...250 416EC9 2CMA102025R1000
Red 440...460 60 416EC11 2CMA102026R1000
Dimensions (mm)
Type A B Dmax
B
D max
216EC... 135.5 74.5 14
316EC... 155 87 17
416EC... 156 90.5 17
A
10/11
—
Connectors
IP44
32 A. Splashproof
Housing in plastic (PA). Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
232EC9 2P+E
3 Grey AC 232EC1 2CMA102027R1000 10 0.26
Green > 50 V~ >300...500 232EC2 2CMA102028R1000
Yellow 100...130 50 and 60 232EC4 2CMA102030R1000
Blue 200...250 232EC6 2CMA102031R1000
Red 380...415 232EC9 2CMA102032R1000
Grey transf 232EC12 2CMA102034R1000
3P+E
4 Grey AC 332EC1 2CMA102035R1000 10 0.28
Green > 50 V~ >300...500 332EC2 2CMA102036R1000
10
Red 380/440 50/60 332EC3 2CMA102037R1000
Yellow 100...130 50 and 60 332EC4 2CMA102038R1000
Black 600...690 332EC5 2CMA102039R1000
Red 380...415 332EC6 2CMA102040R1000
Black 480...500 332EC7 2CMA102041R1000
Blue 200...250 332EC9 2CMA102042R1000
Green > 50 V~ 100...300 332EC10 2CMA102043R1000
Red 440...460 60 332EC11 2CMA102044R1000
Grey transf 50 and 60 332EC12 2CMA102045R1000
3P+N+E
5 Grey AC 432EC1 2CMA102046R1000 10 0.30
Green > 50 V~ >300...500 432EC2 2CMA102047R1000
Red 380...440 50/60 432EC3 2CMA102048R1000
Yellow 100...130 50 and 60 432EC4 2CMA102049R1000
Black 600...690 432EC5 2CMA102050R1000
Red 346...415 432EC6 2CMA102051R1000
Black 480...500 432EC7 2CMA102052R1000
Blue 208...250 432EC9 2CMA102053R1000
Red 440...460 60 432EC11 2CMA102054R1000
Dimensions (mm)
Type A B Dmax
B
D max
232EC... 182 93.5 22
332EC... 182 93.5 22
432EC... 182.5 99 22
A
10/12 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
for wall mounting, IP44
16 A. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M20 insert for top cable entry.
Rear knock-out cable entry. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
416BS9 3 Grey AC 216BS1 2CMA193293R1000 10 0.15
Yellow 100...130 50 and 60 216BS4 2CMA193289R1000
Blue 200...250 216BS6 2CMA193290R1000
Red 380...415 216BS9 2CMA193291R1000
Grey transf. 216BS12 2CMA193292R1000
3P+E
4 Grey AC 316BS1 2CMA193303R1000 10 0.19
Yellow 100...130 50 and 60 316BS4 2CMA193296R1000
Black 600...690 316BS5 2CMA193297R1000
10
3P+N+E
5 Grey AC 416BS1 2CMA193311R1000 10 0.20
Green >50 V~ >300...500 416BS2 2CMA193304R1000
Black 600...690 50 and 60 416BS5 2CMA126699R1000
Red 346...415 416BS6 2CMA193307R1000
Blue 208...250 416BS9 2CMA193309R1000
Red 440...460 60 416BS11 2CMA193310R1000
B
C1 B ØF G ØDmax
ØA Dimensions (mm)
C1 ØF G ØDmax
ØA Type A B C C1 Dmax E1 F G H
216BS.. 23 66 75 54 18/M20 72 5.5 27 110
C 316BS.. 23 79 91 67 18/M20 78 5.5 30 124
H
C 416BS.. 23 79 91 67 18/M20 81 5.5 30 125
H
E1
E1
10/13
—
Inlets
for wall mounting, IP44
32 A. IP44. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M25 insert for top cable entry.
Rear knock-out cable entry. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
Grey AC 232BS1 2CMA193317R1000 10 0.25
Yellow 100...130 50 and 60 232BS4 2CMA193313R1000
Blue 200...250 232BS6 2CMA193314R1000
3 Red 380...415 232BS9 2CMA193315R1000
3P+E
4 Grey AC 332BS1 2CMA193327R1000 10 0.27
Red 380/440 50/60 332BS3 2CMA193319R1000
Yellow 100...130 50 and 60 332BS4 2CMA193320R1000
Black 600...690 332BS5 2CMA193321R1000
10
Red 380...415 332BS6 2CMA193322R1000
Black 480...500 332BS7 2CMA193323R1000
Blue 200...250 332BS9 2CMA193324R1000
Green > 50 V~ 100...300 332BS10 2CMA193325R1000
Red 440...460 60 332BS11 2CMA193326R1000
3P+N+E
5 Grey AC 432BS1 2CMA193335R1000 10 0.29
Black 600...690 50 and 60 432BS5 2CMA126700R1000
Red 346...415 432BS6 2CMA193331R1000
Black 480...500 432BS7 2CMA193332R1000
Blue 208...250 432BS9 2CMA193333R1000
B
C1 B ØF G ØDmax Dimensions (mm)
ØA
C1 ØF G ØDmax
ØA Type A B C C1 Dmax E1 F G H
232BS.. 29 85 111 72 22/M25 94 5.5 34 153
C 332BS.. 29 85 111 72 22/M25 94 5.5 34 153
H 432BS.. 29 85 111 72 22/M25 96 5.5 34 154
C
H
E1
E1
10/14 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
for panel mounting with minimized or unified straight flange, IP44
16 A. Splashproof
Housing in plastic (PA). Minimized flange, Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216B6 2P+E
3 Grey AC 216B1 2CMA193341R1000 10 0.10
Blue 200...250 50 and 60 216B6 2CMA193338R1000
3P+E
4 Grey AC 316B1 2CMA193351R1000 10 0.13
Yellow 100...130 50 and 60 316B4 2CMA100187R1000
Black 600...690 316B5 2CMA193345R1000
Red 380...415 316B6 2CMA193346R1000
Blue 200...250 316B9 2CMA193348R1000
3P+N+E
10
B E
E1
H
H1
øD C
ø4.2 E3
C
E4
B E2
E1
Dimensions (mm) H
H1
Type B C D E E1 E3 E4 H H1
øD
216B... 9 44-47
C 49 75 40.5 21.5 46.5 4 30.0
316B... 9 50-52 59 80 46.8 21.0 47.0 5 34.0
416B... 9 50-52 59 90 52.5 21.0 46.5 7 38.0
ø4.2
C E3
E4
10/15
—
Inlets
for panel mounting with minimized or unified straight flange, IP44
16 A. IP44. Splashproof
Housing in plastic (PA). Unified flange, Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432BU6 3P+E
4 Blue 200...250 50 and 60 316BU9 2CMA163824R1000 10 0.13
3P+N+E
5 Black 600...690 50 and 60 416BU5 2CMA100235R1000 10 0.14
Red 346...415 416BU6 2CMA193468R1000
32 A. IP44. Splashproof
Housing in plastic (PA). Unified flange, Cable area 2.5...6 mm2
Weight
10
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232BU1 2CMA193437R1000 10 0.15
Blue 200...250 50 and 60 232BU6 2CMA193434R1000
3P+E
4 Grey AC 332BU1 2CMA193447R1000 10 0.17
Black 600...690 50 and 60 332BU5 2CMA193441R1000
Red 380...415 332BU6 2CMA193442R1000
Blue 200...250 332BU9 2CMA193444R1000
3P+N+E
5 Grey AC 432BU1 2CMA193455R1000 10 0.19
Red 346...415 50 and 60 432BU6 2CMA193451R1000
B E
Dimensions (mm)
E1
H Type B C D E E1 E3 E4 H H1
H1 316BU... 9 60-61 59 90 52.5 21.0 46.5 7 38.0
B E2
E1
H
H1
øD C
ø4.2
C E3
E4
10/16 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for wall mounting, IP44
16 A. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M20 insert for top cable entry.
Rear knock-out cable entry. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
Grey AC 216RS1 2CMA193101R1000 10 0.22
216RS6
Yellow 100...130 50 and 60 216RS4 2CMA193097R1000
Blue 200...250 216RS6 2CMA193098R1000
Red 380...415 216RS9 2CMA193099R1000
3 Grey transf. 216RS12 2CMA193100R1000
3P+E
4 Grey AC 316RS1 2CMA193111R1000 10 0.24
Yellow 100...130 50 and 60 316RS4 2CMA193104R1000
Black 600...690 316RS5 2CMA193105R1000
10
3P+N+E
5 Grey AC 416RS1 2CMA193119R1000 10 0.26
Green > 50 V~ 300...500 416RS2 2CMA193112R1000
Black 600..690 50 and 60 416RS5 2CMA126666R1000
Red 346...415 416RS6 2CMA193115R1000
Blue 208...250 416RS9 2CMA193117R1000
Red 440...460 60 416RS11 2CMA193118R1000
E E A A
G G Dimensions (mm)
C1 C1 ØF ØF ØDmax
ØDmax
ØH ØH
Type A B C C1 Dmax E F G H
216RS.. 91 117 75 54 18/M20 66 5.5 27 23
316RS.. 100 132 91 67 18/M20 79 5.5 30 23
C C
416RS.. 104 134 91 67 18/M20 79 5.5 30 23
B B
10/17
—
Socket outlet
for wall mounting, IP44
32 A. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M25 insert for top cable entry.
Rear knock-out cable entry. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232RS1 2CMA193125R1000 10 0.30
432RS6 Yellow 100...130 50 and 60 232RS4 2CMA193121R1000
Blue 200...250 232RS6 2CMA193122R1000
Red 380...415 232RS9 2CMA193123R1000
3P+E
4 Grey AC 332RS1 2CMA193135R1000 10 0.32
Red 380/440 50/60 332RS3 2CMA193127R1000
Yellow 100...130 50 and 60 332RS4 2CMA193128R1000
Black 600...690 332RS5 2CMA193129R1000
10
Red 380...415 332RS6 2CMA193130R1000
Black 480...500 332RS7 2CMA193131R1000
Blue 200...250 332RS9 2CMA193132R1000
Green > 50 V~ 100...300 332RS10 2CMA193133R1000
Red 440...460 60 332RS11 2CMA193134R1000
3P+N+E
5 Grey AC 432RS1 2CMA193143R1000 10 0.34
Black 600...690 50 and 60 432RS5 2CMA126667R1000
Red 346...415 432RS6 2CMA193139R1000
Black 480...500 432RS7 2CMA193140R1000
Blue 208...250 432RS9 2CMA193141R1000
E E A A Dimensions (mm)
G G
C1 C1 ØF ØF ØDmax
ØDmax
ØH ØH Type A B C C1 Dmax E F G H
232RS.. 118 163 111 72 22/M25 85 5.5 34 29
332RS.. 116 163 111 72 22/M25 85 5.5 34 29
C C 432RS.. 121 164 111 72 22/M25 85 5.5 34 29
B B
10/18 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Additional products and accessories
Surface socket outlet with schuko
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
CUE416-6+R/UJP 3P+E
5 Blue 200...250 50 and 60 CUE316-9+R/UJP 2CMA178363R1000 10 0.34
3P+N+E
5 Red 400/230 50 and 60 CUE416-6+R/UJP 2CMA178301R1000 10 0.34
Weight
Terminals/ Color Pkg pkg
Poles Voltage Frequency Type Order Code qty (1pce)
10
code
V Hz kg
3P+N+E
5 Red 400/230 50 and 60 CUE416-6+R/FR16* 2CMA101642R1000 10 0.34
*French Standard
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+N+E
5 Red 400/230 50 and 60 CUE416-6+R/BS13* 2CMA101635R1000 10 0.34
*British Standard
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+N+E
5 Red 400/230 50 and 60 CUE 416-6+R/DK16A* 2CMA105921R1000 10 0.34
*Danish Standard
71
Dimensions (mm)
Type A B C D E
CUE416-6+R/UJP 160 120 72 82 110
B
A
111
C E
D
10/19
—
Socket outlet
for wall mounting, IP44
16 A. Watertight
Housing in plastic (PBT). Cable entry with knock-outs 2xM20 on bottom and 2xM25 on top. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216ERT6
3 Grey AC 216ERT1 2CMA101739R1000 1 0.36
Green > 50 V~ >300...500 216ERT2 2CMA101740R1000
Yellow 100...130 50 and 60 216ERT4 2CMA101719R1000
Blue 200...250 216ERT6 2CMA101742R1000
Grey transf. 216ERT12 2CMA101743R1000
3P+E
4 Grey AC 316ERT1 2CMA101744R1000 1 0.39
Green > 50 V~ >300...500 316ERT2 2CMA101745R1000
Yellow 100...130 50 and 60 316ERT4 2CMA101746R1000
10
Black 600...690 316ERT5 2CMA101747R1000
Red 380...415 316ERT6 2CMA101720R1000
Black 480...500 316ERT7 2CMA101748R1000
Blue 200...250 316ERT9 2CMA101721R1000
Green > 50 V~ 100...300 316ERT10 2CMA101749R1000
Red 440...460 60 316ERT11 2CMA101722R1000
Grey transf. 316ERT12 2CMA101750R1000
3P+N+E
5 Grey AC 416ERT1 2CMA101751R1000 10 0.41
Green > 50 V~ >300...500 416ERT2 2CMA101752R1000
Yellow 100...130 50 and 60 416ERT4 2CMA101753R1000
Red 346...415 416ERT6 2CMA101723R1000
Black 480...500 416ERT7 2CMA101754R1000
Blue 208...250 416ERT9 2CMA101755R1000
Red 440...460 60 416ERT11 2CMA101756R1000
C
Ø5
2 x M20
B G
F A
D 2 x M25
E
Dimensions (mm)
Type A B C D E F 6
216ERT...416ERT... 134 139 82 71 80 120 111
10/20 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for wall mounting, IP44
32 A. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs 2xM25 on top and 2xM25 on bottom. Cable area 2.5...10 mm2
Weight
Color Pkg pkg
Terminals code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
232ERT6
2P+E
Green >50 >300 ... 500 232ERT2 2CMA101757R1000 1 0.42
Yellow 100 ... 130 50, 60 232ERT4 2CMA101759R1000
Blue 200 ... 250 232ERT6 2CMA101724R1000
Red 380 ... 415 232ERT9 2CMA101760R1000
Grey Isol. Transformer 232ERT12 2CMA101761R1000
3P+E
Green >50 >300 ... 500 332ERT2 2CMA101762R1000 1 0.44
Red 380/440 50/60 332ERT3 2CMA101763R1000
10
3P+N+E
Green >50 >300 ... 500 432ERT2 2CMA101770R1000 1 0.5
Yellow 57/100 ... 75/130 50, 60 432ERT4 2CMA101771R1000
Red 200/346 ... 240/415 432ERT6 2CMA101727R1000
Black 277/480 ... 288/500 432ERT7 2CMA101772R1000
Blue 120/208 ... 144/250 432ERT9 2CMA101773R1000
Red 440 ... 460 60 432ERT11 2CMA101774R1000
C
Ø5
2 x M20
B G
F A
D 2 x M25
E
Dimensions (mm)
Type A B C D E F 6
232ERT... 432ERT 139 139 82 71 80 121 111
263ERT... 463ERT 225 186 100 124 149 149 129
10/21
—
Socket outlet
for wall mounting, IP44
63 A. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs 2 x M32/M40 + 1 x M20 on top. 1 x M20 + 1 x M32/M40 on bottom.
Cable area 6...25 mm2
Weight
Color Pkg pkg
Terminals code Voltage Frequency Type Order Code qty (1pce)
263ERT6
V Hz kg
2P+E
Yellow 100 ... 130 50, 60 263ERT4 2CMA101894R1000 1 1.4
Blue 200 ... 250 263ERT6 2CMA101895R1000
3P+E
Yellow 100 ... 130 50, 60 363ERT4 2CMA101888R1000 1 1.4
Black 600 ... 690 363ERT5 2CMA101889R1000
Red 380 ... 415 363ERT6 2CMA101890R1000
Black 480 ... 500 363ERT7 2CMA101891R1000
Blue 200 ... 250 363ERT9 2CMA101892R1000
10
Red 440 ... 460 60 363ERT11 2CMA101893R1000
3P+N+E
Yellow 57/100 ... 75/130 50, 60 463ERT4 2CMA101884R1000 1 1.45
Red 200/346 ... 240/415 463ERT6 2CMA101885R1000
Blue 120/208 ... 144/250 463ERT9 2CMA101886R1000
Red 250/440 ... 265/460 60 463ERT11 2CMA101887R1000
C
Ø5
2 x M20
B G
F A
D 2 x M25
E
Dimensions (mm)
Type A B C D E F 6
232ERT... 432ERT 139 139 82 71 80 121 111
263ERT... 463ERT 225 186 100 124 149 149 129
10/22 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for panel mounting with unified straight flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216RU6 V Hz kg
2P+E
3 Grey AC 216RU1 2CMA193173R1000 10 0.15
Yellow 100...130 50 and 60 216RU4 2CMA193169R1000
Blue 200...250 216RU6 2CMA193170R1000
Red 380...415 216RU9 2CMA193171R1000
Grey transf. 216RU12 2CMA193172R1000
3P+E
4 Grey AC 316RU1 2CMA193183R1000 10 0.18
Yellow 100...130 50 and 60 316RU4 2CMA193176R1000
Black 600...690 316RU5 2CMA193177R1000
10
3P+N+E
5 Grey AC 416RU1 2CMA193191R1000 10 0.20
Green > 50 V~ >300...500 416RU2 2CMA193184R1000
Black 600...690 50 and 60 416RU5 2CMA126673R1000
Red 346...415 416RU6 2CMA193187R1000
Blue 208...250 416RU9 2CMA193189R1000
D2
Dimensions (mm)
C1
Type C C1 D D2 E E1 H
216RU.. 60-61 60-61 49 75 56 29 79
H
D2 C ØD 316RU.. 60-61 60-61 59 75 58 30 87
416RU.. 60-61 60-61 59 75 60 31 89
Ø 4.2
E1 E
10/23
—
Socket outlet
for panel mounting with unified straight flange, IP44
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432RU6
3 Grey AC 232RU1 2CMA193245R1000 10 0.21
Yellow 100...130 50 and 60 232RU4 2CMA193241R1000
Blue 200...250 232RU6 2CMA193242R1000
3P+E
4 Grey AC 332RU1 2CMA193255R1000 10 0.22
Black 600...690 50 and 60 332RU5 2CMA193249R1000
Red 380...415 332RU6 2CMA193250R1000
Black 480...500 332RU7 2CMA193251R1000
Blue 200...250 332RU9 2CMA193252R1000
10
3P+N+E
5 Grey AC 432RU1 2CMA193263R1000 10 0.24
Black 600...690 50 and 60 432RU5 2CMA126674R1000
Red 346...415 432RU6 2CMA193259R1000
Blue 208...250 432RU9 2CMA101699R1000
D2
Dimensions (mm)
C1
Type C C1 D D2 E E1 H
232RU.. 60-61 60-61 66 75 70 34 93
H
D2 C ØD 332RU.. 60-61 60-61 66 75 70 34 93
432RU.. 60-61 60-61 66 75 71 34 99
Ø 4.2
E1 E
10/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for panel mounting with unified angled flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216RAU6
2P+E
3 Grey AC 216RAU1 2CMA193221R1000 10 0.19
Green > 50 V~ >300...500 216RAU2 2CMA101342R1000
Yellow 100...130 50 and 60 216RAU4 2CMA193217R1000
Blue 200...250 216RAU6 2CMA193218R1000
Red 380...415 216RAU9 2CMA193219R1000
Grey transf. 216RAU12 2CMA193220R1000
3P+E
4 Grey AC 316RAU1 2CMA193231R1000 10 0.22
Yellow 100...130 50 and 60 316RAU4 2CMA193224R1000
10
3P+N+E
5 Grey AC 416RAU1 2CMA193239R1000 10 0.24
Green > 50 V~ >300...500 416RAU2 2CMA193232R1000
Yellow 100...130 50 and 60 416RAU4 2CMA101343R1000
Black 600...690 416RAU5 2CMA126678R1000
Red 346...415 416RAU6 2CMA193235R1000
Blue 208...250 416RAU9 2CMA193237R1000
D2 D2
C1 C1 Dimensions (mm)
Type C C1 D D2 E E1 H
216RAU.. 85 85 98 110 48 48 110
D2 C
D2 C ØD ØD H H 316RAU.. 85 85 98 110 50 48 110
416RAU.. 85 85 98 110 51 50 110
Ø 4.2Ø 4.2 E1 E1 E E
10/25
—
Socket outlet
for panel mounting with unified angled flange, IP44
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432RAU6 2P+E
3 Grey AC 232RAU1 2CMA193269R1000 10 0.25
Yellow 100...130 50 and 60 232RAU4 2CMA193265R1000
Blue 200...250 232RAU6 2CMA193266R1000
3P+E
4 Grey AC 332RAU1 2CMA193279R1000 10 0.26
Black 600...690 50 and 60 332RAU5 2CMA193273R1000
Red 380...415 332RAU6 2CMA193274R1000
Black 480...500 332RAU7 2CMA193275R1000
Blue 200...250 332RAU9 2CMA193276R1000
10
3P+N+E
5 Grey AC 432RAU1 2CMA193287R1000 10 0.28
Black 600...690 50 and 60 432RAU5 2CMA126679R1000
Red 346...415 432RAU6 2CMA193283R1000
D2 D2
C1 C1 Dimensions (mm)
Type C C1 D D2 E E1 H
232RAU... 85 85 98 110 61 53 110
D2 C
D2 C ØD ØD H H 332RAU... 85 85 98 110 61 53 110
432RAU... 85 85 98 110 63 54 110
Ø 4.2Ø 4.2 E1 E1 E E
10/26 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for panel mounting with minimized straight flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216R6
2P+E
3 Yellow 100...130 50 and 60 216R4 2CMA193145R1000 10 0.14
Blue 200...250 216R6 2CMA193146R1000
Red 380...415 216R9 2CMA193147R1000
Grey transf. 216R12 2CMA193148R1000
3P+E
4 Grey AC 316R1 2CMA193159R1000 10 0.17
Yellow 100...130 50 and 60 316R4 2CMA193152R1000
Black 600...690 316R5 2CMA193153R1000
Red 380...415 316R6 2CMA193154R1000
10
3P+N+E
5 Grey AC 416R1 2CMA193167R1000 10 0.19
Green > 50 V~ >300...500 416R2 2CMA193160R1000
Red 346...415 416R6 2CMA193163R1000
Blue 208...250 50 and 60 416R9 2CMA193165R1000
D2 Dimensions (mm)
C1
Type C C1 D D2 E E1 H
216R.. 44-47 44-47 49 56 56 29 73
H 316R.. 50-52 50-52 59 66 58 30 87
D2 C ØD
416R.. 50-52 50-52 59 66 60 31 89
Ø 4.2
E1 E
10/27
—
Socket outlet
for panel mounting with minimized angled flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216RAM6
3 Grey AC 216RAM1 2CMA170007R1000 10 0.21
Yellow 100...130 50 and 60 216RAM4 2CMA170003R1000
Blue 200...250 216RAM6 2CMA170004R1000
Red 380...415 216RAM9 2CMA170005R1000
Grey transf. 216RAM12 2CMA170006R1000
3P+E
4 Grey AC 316RAM1 2CMA170017R1000 10 0.22
Yellow 100...130 50 and 60 316RAM4 2CMA170010R1000
Black 600...690 316RAM5 2CMA170011R1000
10
Red 380...415 316RAM6 2CMA170012R1000
Black 480...500 316RAM7 2CMA170013R1000
Blue 200...250 316RAM9 2CMA170014R1000
Green > 50 V~ 100...300 316RAM10 2CMA170015R1000
Red 440...460 60 316RAM11 2CMA170016R1000
3P+N+E
5 Grey AC 416RAM1 2CMA170025R1000 10 0.24
Green > 50 V~ >300...500 416RAM2 2CMA170018R1000
Red 346...415 50 and 60 416RAM6 2CMA170021R1000
Blue 208...250 416RAM9 2CMA170023R1000
D2 D2 Dimensions (mm)
C1 C1
Type C C1 D D2 D3 E E1 H
216RAM.. 55 55 63 70 78 53 42 76
316RAM.. 66 66 78 83 89 53 46 85
D3 D3C C ØD ØD H H 416RAM.. 66 66 78 83 89 55 48 89
Ø 4.2
Ø 4.2
E1 E1 E E
10/28 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for panel mounting with minimized angled flange, IP44
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
332RAM6
3 Grey AC 232RAM1 2CMA170030R1000 10 0.21
Yellow 100...130 50 and 60 232RAM4 2CMA170026R1000
Blue 200...250 232RAM6 2CMA170027R1000
3P+E
4 Grey AC 332RAM1 2CMA170040R1000 10 0.22
Black 600...690 50 and 60 332RAM5 2CMA170034R1000
Red 380...415 332RAM6 2CMA170035R1000
Black 480...500 332RAM7 2CMA170036R1000
Blue 200...250 332RAM9 2CMA170037R1000
10
3P+N+E
5 Grey AC 432RAM1 2CMA170048R1000 10 0.24
Red 346...415 50 and 60 432RAM6 2CMA170044R1000
D2 D2
Dimensions (mm)
C1 C1
Type C C1 D D2 D3 E E1 H
232RAM... 75 75 87 93 99 61 52 98
332RAM... 75 75 87 93 99 61 52 98
D3 D3C C ØD ØD H H
432RAM... 75 75 87 93 99 64 52 101
Ø 4.2
Ø 4.2
E1 E1 E E
10/29
—
New watertight Easy & Safe
Our new IP67 Easy & Safe is a perfect choice in most applications
where water and dirt can occur. They combine easy access to contact
parts during installation with high protection degree while the
products are in use. Electrical contacts protected against liquids and
dirt retains its performance over time. High contact performance
means reliability, reducing downtime and lowers maintenance costs.
10
10/30 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
IP67
16 A. Watertight
Housing in plastic (PA). Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216EP6W V Hz kg
2P+E
3 Grey AC 216EP1W 2CMA101069R1000 10 0.13
Grey >50...250 DC 216EP3W 2CMA166456R1000
Yellow 100...130 50 and 60 216EP4W 2CMA101071R1000
Blue 200...250 216EP6W 2CMA101072R1000
Red 380...415 216EP9W 2CMA101073R1000
Grey transf 216EP12W 2CMA101074R1000
3P+E
4 Grey AC 316EP1W 2CMA101075R1000 10 0.19
Green > 50 V~ >300...500 316EP2W 2CMA101076R1000
10
3P+N+E
5 Grey AC 416EP1W 2CMA101085R1000 10 0.21
Green > 50 V~ >300...500 416EP2W 2CMA101086R1000
Red 380...440 50/60 416EP3W 2CMA101087R1000
Yellow 100...130 50 and 60 416EP4W 2CMA101088R1000
Red 346...415 416EP6W 2CMA101089R1000
Black 480...500 416EP7W 2CMA101090R1000
Blue 208...250 416EP9W 2CMA101091R1000
Red 440...460 60 416EP11W 2CMA101092R1000
Dimensions (mm)
Type A B C Dmax
216EP...W 134 73 100 14
316EP...W 161 81 127 17
416EP...W 158 87 125 17
10/31
—
Plugs
IP67
32 A. Watertight
Housing in plastic (PA). Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432EP6W 2P+E
3 Grey AC 232EP1W 2CMA101093R1000 10 0.23
Yellow 100...130 50 and 60 232EP4W 2CMA101094R1000
Blue 200...250 232EP6W 2CMA101095R1000
Red 380...415 232EP9W 2CMA101096R1000
Grey transf 232EP12W 2CMA101097R1000
3P+E
4 Grey AC 332EP1W 2CMA101098R1000 10 0.25
Green > 50 V~ >300...500 332EP2W 2CMA101099R1000
Red 380/440 50/60 332EP3W 2CMA101100R1000
10
Yellow 100...130 50 and 60 332EP4W 2CMA101101R1000
Black 600...690 332EP5W 2CMA101102R1000
Red 380...415 332EP6W 2CMA101103R1000
Black 480...500 332EP7W 2CMA101104R1000
Blue 200...250 332EP9W 2CMA101105R1000
Green 100...300 >50 332EP10W 2CMA101106R1000
Red 440...460 60 332EP11W 2CMA101107R1000
3P+N+E
5 Grey AC 432EP1W 2CMA101108R1000 10 0.25
Green > 50 V~ >300...500 432EP2W 2CMA101109R1000
Red 380...440 50/60 432EP3W 2CMA101110R1000
Yellow 100...130 50 and 60 432EP4W 2CMA101111R1000
Red 346...415 432EP6W 2CMA101112R1000
Black 480...500 432EP7W 2CMA101113R1000
Blue 208...250 432EP9W 2CMA101114R1000
Red 440...460 60 432EP11W 2CMA101115R1000
Dimensions (mm)
Type A B C Dmax
232EP...W 183 91 141 22
332EP...W 183 91 141 22
432EP...W 183 99 141 22
10/32 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Connectors
IP67
16 A. Watertight
Housing in plastic (PA). Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216EC6W
V Hz kg
2P+E
3 Grey AC 216EC1W 2CMA101116R1000 10 0.17
Yellow 100...130 50 and 60 216EC4W 2CMA101118R1000
Blue 200...250 216EC6W 2CMA101119R1000
Red 380...415 216EC9W 2CMA101120R1000
Grey transf 216EC12W 2CMA101121R1000
3P+E
4 Grey AC 316EC1W 2CMA101122R1000 10 0.23
Green > 50 V~ >300...500 316EC2W 2CMA101123R1000
Red 380/440 50/60 316EC3W 2CMA101124R1000
10
3P+N+E
5 Grey AC 416EC1W 2CMA101132R1000 10 0.26
Green > 50 V~ >300...500 416EC2W 2CMA101133R1000
Red 380...440 50/60 416EC3W 2CMA101134R1000
Yellow 100...130 50 and 60 416EC4W 2CMA101135R1000
Red 346...415 416EC6W 2CMA101136R1000
Black 480...500 416EC7W 2CMA101137R1000
Blue 208...250 416EC9W 2CMA101138R1000
Red 440...460 60 416EC11W 2CMA101139R1000
Dimensions (mm)
Type A B Dmax
216EC...W 146 81 14
316EC...W 169 88 17
416EC...W 169 92 17
10/33
—
Connectors
IP67
32 A. Watertight
Housing in plastic (PA). Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432EC6W
2P+E
3 Grey AC 232EC1W 2CMA101140R1000 10 0.28
Yellow 100...130 50 and 60 232EC4W 2CMA101141R1000
Blue 200...250 232EC6W 2CMA101142R1000
Red 380...415 232EC9W 2CMA101143R1000
Grey transf 232EC12W 2CMA101144R1000
3P+E
4 Grey AC 332EC1W 2CMA101145R1000 10 0.30
Green > 50 V~ >300...500 332EC2W 2CMA101146R1000
Red 380/440 50/60 332EC3W 2CMA101147R1000
10
Yellow 100...130 50 and 60 332EC4W 2CMA101148R1000
Black 600...690 332EC5W 2CMA101149R1000
Red 380...415 332EC6W 2CMA101150R1000
Black 480...500 332EC7W 2CMA101151R1000
Blue 200...250 332EC9W 2CMA101152R1000
Green > 50 V~ 100...300 332EC10W 2CMA101153R1000
Red 440...460 60 332EC11W 2CMA101154R1000
3P+N+E
5 Grey AC 432EC1W 2CMA101155R1000 10 0.30
Green > 50 V~ >300...500 432EC2W 2CMA101156R1000
Red 380...440 50/60 432EC3W 2CMA101157R1000
Yellow 100...130 50 and 60 432EC4W 2CMA101158R1000
Red 346...415 432EC6W 2CMA101159R1000
Black 480...500 432EC7W 2CMA101160R1000
Blue 208...250 432EC9W 2CMA101161R1000
Red 440...460 60 432EC11W 2CMA101162R1000
Dimensions (mm)
Type A B Dmax
232EC...W 195 98 22
332EC...W 195 98 22
432EC...W 195 104 22
10/34 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
for wall mounting, IP67
16 A. Watertight
Housing in plastic (PA). Cable gland included. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216EBS6W 2P+E
3 Grey AC 216EBS1W 2CMA101163R1000 10 0.20
Yellow 100...130 50 and 60 216EBS4W 2CMA101165R1000
Blue 200...250 216EBS6W 2CMA101166R1000
Red 380...415 216EBS9W 2CMA101167R1000
Grey transf 216EBS12W 2CMA101168R1000
3P+E
4 Grey AC 316EBS1W 2CMA101169R1000 10 0.23
Green > 50 V~ >300...500 316ESB2W 2CMA101170R1000
Red 380/440 50/60 316EBS3W 2CMA101171R1000
10
3P+N+E
5 Grey AC 416EBS1W 2CMA101179R1000 10 0.25
Green > 50 V~ >300...500 416EBS2W 2CMA101180R1000
Red 380...440 50/60 416EBS3W 2CMA101181R1000
Yellow 100...130 50 and 60 416EBS4W 2CMA101182R1000
Red 346...415 416EBS6W 2CMA101183R1000
Black 480...500 416EBS7W 2CMA101184R1000
Blue 208...250 416EBS9W 2CMA101185R1000
Red 440...460 60 416EBS11W 2CMA101186R1000
C2
C1 M25
∅F G
∅A
H
∅B1
B E1
Dimensions (mm)
Type A B C C1 C2 E1 ØF G H
216EBS...W 25 88.5 40 63.5 73.5 112 4.5 34.75 135
316EBS...W 25 88.5 40 63.5 73.5 108 4.5 34.75 138
416EBS...W 25 88.5 40 63.5 73.5 112 4.5 34.75 140
10/35
—
Inlets
for wall mounting, IP67
32 A. Watertight
Housing in plastic (PA). Cable gland included. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432EBS6W 3 Grey AC 232EBS1W 2CMA101187R1000 10 0.26
Yellow 100...130 50 and 60 232EBS4W 2CMA101188R1000
Blue 200...250 232EBS6W 2CMA101189R1000
Red 380...415 232EBS9W 2CMA101190R1000
Grey transf 232EBS12W 2CMA101191R1000
3P+E
4 Grey AC 332EBS1W 2CMA101192R1000 10 0.27
Green > 50 V~ >300...500 332EBS2W 2CMA101193R1000
Red 380/440 50/60 332EBS3W 2CMA101194R1000
10
Yellow 100...130 50 and 60 332EBS4W 2CMA101195R1000
Black 600...690 332EBS5W 2CMA101196R1000
Red 380...415 332EBS6W 2CMA101197R1000
Black 480...500 332EBS7W 2CMA101198R1000
Blue 200...250 332EBS9W 2CMA101199R1000
Green > 50 V~ 100...300 332EBS10W 2CMA101200R1000
Red 440...460 60 332EBS11W 2CMA101201R1000
3P+N+E
5 Grey AC 432EBS1W 2CMA101202R1000 10 0.28
Green > 50 V~ >300...500 432EBS2W 2CMA101203R1000
Red 380...440 50/60 432EBS3W 2CMA101204R1000
Yellow 100...130 50 and 60 432EBS4W 2CMA101205R1000
Red 346...415 432EBS6W 2CMA101206R1000
Black 480...500 432EBS7W 2CMA101207R1000
Blue 208...250 432EBS9W 2CMA101208R1000
Red 440...460 60 432EBS11W 2CMA101209R1000
C2
C1 M25
∅F G
∅A
B E1
Dimensions (mm)
Type A B C C1 C2 E1 ØF G H
232EBS...W 25 91 40 63.5 73.5 106 4.5 34.75 150
332EBS...W 25 91 40 63.5 73.5 106 4.5 34.75 150
432EBS...W 25 99 40 63.5 73.5 110 4.5 34.75 152
10/36 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
for panel mounting with unified straight flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216EBU6W
2P+E
3 Grey AC 216EBU1W 2CMA101257R1000 10 0.11
Yellow 100...130 50 and 60 216EBU4W 2CMA101258R1000
Blue 200...250 216EBU6W 2CMA101259R1000
Red 380...415 216EBU9W 2CMA101260R1000
3P+E
4 Grey AC 316EBU1W 2CMA101261R1000 10 0.14
Yellow 100...130 50 and 60 316EBU4W 2CMA101262R1000
Black 600...690 316EBU5W 2CMA101263R1000
Red 380...415 316EBU6W 2CMA101264R1000
10
3P+N+E
5 Grey AC 416EBU1W 2CMA101268R1000 10 0.16
Yellow 100...130 50 and 60 416EBU4W 2CMA101269R1000
Red 346...415 416EBU6W 2CMA101270R1000
Black 480...500 416EBU7W 2CMA101271R1000
Blue 208...250 416EBU9W 2CMA101812R1000
Red 440...460 60 416EBU11W 2CMA101272R1000
Dimensions (mm)
Type B E3 E4
216EBU...W 94 17 48.5
316EBU...W 90 17 48.5
416EBU...W 93.5 17 48.5
10/37
—
Inlets
for panel mounting with unified straight flange, IP67
32 A. Watertight
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432EBU6W
3 Grey AC 232EBU1W 2CMA101273R1000 10 0.17
Yellow 100...130 50 and 60 232EBU4W 2CMA101274R1000
Blue 200...250 232EBU6W 2CMA101275R1000
Red 380...415 232EBU9W 2CMA101813R1000
3P+E
4 Grey AC 332EBU1W 2CMA101276R1000 10 0.18
Red 380/440 50/60 332EBU3W 2CMA101277R1000
Yellow 100...130 50 and 60 332EBU4W 2CMA101278R1000
Red 380...415 332EBU6W 2CMA101279R1000
10
Black 480...500 332EBU7W 2CMA101280R1000
Blue 200...250 332EBU9W 2CMA101281R1000
Red 440...460 60 332EBU11W 2CMA101282R1000
3P+N+E
5 Grey AC 432EBU1W 2CMA101283R1000 10 0.19
Yellow 100...130 50 and 60 432EBU4W 2CMA101284R1000
Red 346...415 432EBU6W 2CMA101285R1000
Black 480...500 432EBU7W 2CMA101286R1000
Blue 208...250 432EBU9W 2CMA101287R1000
Red 440...460 60 432EBU11W 2CMA101288R1000
Dimensions (mm)
Type B E3 E4
232EBU...W 91 16 58
332EBU...W 91 16 58
432EBU...W 99 16 58
10/38 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for wall mounting, IP67
16 A. Watertight
Housing in plastic (PA). Cable gland included. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216ERS6W 2P+E
3 Grey AC 216ERS1W 2CMA101210R1000 10 0.24
Yellow 100...130 50 and 60 216ERS4W 2CMA101212R1000
Blue 200...250 216ERS6W 2CMA101213R1000
Red 380...415 216ERS9W 2CMA101214R1000
Grey transf 216ERS12W 2CMA101215R1000
3P+E
4 Grey AC 316ERS1W 2CMA101216R1000 10 0.27
Green > 50 V~ >300...500 316ERB2W 2CMA101217R1000
Red 380/440 50/60 316ERS3W 2CMA101218R1000
10
3P+N+E
5 Grey AC 416ERS1W 2CMA101226R1000 10 0.30
Green > 50 V~ >300...500 416ERS2W 2CMA101227R1000
Red 380...440 50/60 416ERS3W 2CMA101228R1000
Yellow 100...130 50 and 60 416ERS4W 2CMA101229R1000
Red 346...415 416ERS6W 2CMA101230R1000
Black 480...500 416ERS7W 2CMA101231R1000
Blue 208...250 416ERS9W 2CMA101232R1000
Red 440...460 60 416ERS11W 2CMA101233R1000
C2
C1 M25
∅F G
∅A
H
∅B1
B E1
Dimensions (mm)
Type A B ØB1 C C1 C2 E1 ØF G H
216ERS...W 25 88.5 73 40 63.5 73.5 112 4.5 34.75 147
316ERS...W 25 88.5 81 40 63.5 73.5 117 4.5 34.75 150
416ERS...W 25 88.5 87 40 63.5 73.5 119 4.5 34.75 151
10/39
—
Socket outlet
for wall mounting, IP67
32 A. Watertight
Housing in plastic (PA). Cable gland included. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232ERS1W 2CMA101234R1000 10 0.31
432ERS6W Yellow 100...130 50 and 60 232ERS4W 2CMA101235R1000
Blue 200...250 232ERS6W 2CMA101236R1000
Red 380...415 232ERS9W 2CMA101237R1000
Grey transf 232ERS12W 2CMA101238R1000
3P+E
4 Grey AC 332ERS1W 2CMA101239R1000 10 0.32
Green > 50 V~ >300...500 332ERS2W 2CMA101240R1000
Red 380/440 50/60 332ERS3W 2CMA101241R1000
10
Yellow 100...130 50 and 60 332ERS4W 2CMA101242R1000
Black 600...690 332ERS5W 2CMA101243R1000
Red 380...415 332ERS6W 2CMA101244R1000
Black 480...500 332ERS7W 2CMA101245R1000
Blue 200...250 332ERS9W 2CMA101246R1000
Green > 50 V~ 100...300 332ERS10W 2CMA101248R1000
Red 440...460 60 332ERS11W 2CMA101247R1000
3P+N+E
5 Grey AC 432ERS1W 2CMA101249R1000 10 0.32
Green > 50 V~ >300...500 432ERS2W 2CMA101250R1000
Red 380...440 50/60 432ERS3W 2CMA101251R1000
Yellow 100...130 50 and 60 432ERS4W 2CMA101252R1000
Red 346...415 432ERS6W 2CMA101253R1000
Black 480...500 432ERS7W 2CMA101254R1000
Blue 208...250 432ERS9W 2CMA101255R1000
Red 440...460 60 432ERS11W 2CMA101256R1000
C2
C1 M25
∅F G
∅A
H
∅B1
B E1
Dimensions (mm)
Type A B ØB1 C C1 C2 E1 ØF G H
232ERS...W 25 88.5 91 40 63.5 73.5 117 4.5 34.75 163
332ERS...W 25 88.5 91 40 63.5 73.5 117 4.5 34.75 163
432ERS...W 25 88.5 99 40 63.5 73.5 120 4.5 34.75 164
10/40 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for wall mounting, IP67
16 A. Watertight
Housing in plastic (PBT). Cable entry with knock-outs 2xM20 on top and 2xM25 on bottom. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3P+E
4 Green > 50 V~ >300...500 316ERT2W 2CMA101778R1000 1 0.35
Yellow 100...130 50 and 60 316ERT4W 2CMA101779R1000
Black 600...690 316ERT5W 2CMA101780R1000
Red 380...415 316ERT6W 2CMA101730R1000
10
3P+N+E
5 Yellow 100...130 50 and 60 416ERT4W 2CMA101784R1000 1 0.39
Red 346...415 416ERT6W 2CMA101733R1000
Black 480...500 416ERT7W 2CMA101785R1000
Blue 208...250 416ERT9W 2CMA101786R1000
Green > 50 V~ 100...300 416ERT10W 2CMA101787R1000
Red 440...460 60 416ERT11W 2CMA101788R1000
C
Ø5
2 x M20
B G
F A
D 2 x M25
E
Dimensions (mm)
Type A B C D E F 6
216ERT...W...416ERT...W 134 139 82 71 80 120 111
10/41
—
Socket outlet
for wall mounting, IP67
32 A. Watertight
Housing in plastic (PBT). Cable entry with knock-outs 2xM20 on bottom and 2xM25 on top. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432ERT6W 3 Yellow 100...130 50 and 60 232ERT4W 2CMA101790R1000 1 0.37
Blue 200...250 232ERT6W 2CMA101791R1000
Red 380...415 232ERT9W 2CMA101792R1000
Grey transf. 232ERT12W 2CMA101793R1000
3P+E
4 Green > 50 V~ >300...500 332ERT2W 2CMA101794R1000 1 0.42
Red 380/440 50/60 332ERT3W 2CMA101734R1000
Yellow 100...130 50 and 60 332ERT4W 2CMA101795R1000
Black 600...690 332ERT5W 2CMA101796R1000
10
Red 380...415 332ERT6W 2CMA101735R1000
Black 480...500 332ERT7W 2CMA101797R1000
Blue 200...250 332ERT9W 2CMA101736R1000
Green > 50 V~ 100...300 332ERT10W 2CMA101798R1000
Red 440...460 60 332ERT11W 2CMA101737R1000
Grey transf. 332ERT12W 2CMA101799R1000
3P+N+E
Green > 50 V~ >300...500 432ERT2W 2CMA101800R1000 1 0.47
Yellow 100...130 50 and 60 432ERT4W 2CMA101801R1000
Red 346...415 432ERT6W 2CMA101738R1000
Black 480...500 432ERT7W 2CMA101802R1000
Blue 208...250 432ERT9W 2CMA101803R1000
Red 440...460 60 432ERT11W 2CMA101804R1000
C
Ø5
2 x M25
B G
F A
D 2 x M25
E
Dimensions (mm)
Type A B C D E F 6
232ERT...W...332ERT...W 140 143 88 71 80 120 111
432ERT...W 142 146 95 71 80 120 111
10/42 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for wall mounting, IP67
63 A. Watertight
Housing in plastic (PBT). Cable entry with knock-outs 2 x M32/M40 + 1 x M20 on top. 1 x M20 + 1 x M32/M40 on bottom.
Cable area 6...25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+E
463ERT6W 4 Black 600...690 50 and 60 363ERT5W 2CMA101898R1000 1 1.45
Red 380...415 363ERT6W 2CMA101899R1000
Black 480...500 363ERT7W 2CMA101900R1000
Blue 200...250 363ERT9W 2CMA101901R1000
Red 440...460 60 363ERT11W 2CMA101902R1000
3P+N+E
5 Red 346...415 50 and 60 463ERT6W 2CMA101896R1000 1 1.55
Blue 208...250 463ERT9W 2CMA101897R1000
10
C
Ø5
2 x M20
B G
F
A
D 2 x M25
E
Dimensions (mm)
Type A B C D E F 6
263ERT...W...463ERT...W 255 215 108 129 150 187 124
10/43
—
Socket outlet
for panel mounting with unified straight flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216ERU6W 2P+E
3 Grey AC 216ERU1W 2CMA101289R1000 10 0.15
Yellow 100...130 50 and 60 216ERU4W 2CMA101290R1000
Blue 200...250 216ERU6W 2CMA101291R1000
Red 380...415 216ERU9W 2CMA101292R1000
3P+E
4 Grey AC 316ERU1W 2CMA101293R1000 10 0.18
Yellow 100...130 50 and 60 316ERU4W 2CMA101294R1000
Black 600...690 316ERU5W 2CMA101295R1000
Red 380...415 316ERU6W 2CMA101296R1000
10
Black 480...500 316ERU7W 2CMA101297R1000
Blue 200...250 316ERU9W 2CMA101298R1000
Red 440...460 60 316ERU11W 2CMA101299R1000
3P+N+E
5 Grey AC 416ERU1W 2CMA101300R1000 10 0.21
Yellow 100...130 50 and 60 416ERU4W 2CMA101301R1000
Red 346...415 416ERU6W 2CMA101302R1000
Black 480...500 416ERU7W 2CMA101303R1000
Blue 208...250 416ERU9W 2CMA101304R1000
Red 440...460 60 416ERU11W 2CMA101305R1000
Dimensions (mm)
Type B E3 E4
216ERU...W 103 27 60
316ERU...W 98 28 60
416ERU...W 99 28 60
10/4 4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
for panel mounting with unified straight flange, IP67
32 A. Watertight
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432ERU6W 3 Grey AC 232ERU1W 2CMA101306R1000 10 0.22
Yellow 100...130 50 and 60 232ERU4W 2CMA101307R1000
Blue 200...250 232ERU6W 2CMA101308R1000
Red 380...415 232ERU9W 2CMA101309R1000
3P+E
4 Grey AC 332ERU1W 2CMA101310R1000 10 0.23
Red 380/440 50/60 332ERU3W 2CMA101311R1000
Yellow 100...130 50 and 60 332ERU4W 2CMA101312R1000
Red 380...415 332ERU6W 2CMA101313R1000
10
3P+N+E
5 Grey AC 432ERU1W 2CMA101317R1000 10 0.23
Yellow 100...130 50 and 60 432ERU4W 2CMA101318R1000
Red 346...415 432ERU6W 2CMA101319R1000
Black 480...500 432ERU7W 2CMA101320R1000
Blue 208...250 432ERU9W 2CMA101321R1000
Red 440...460 60 432ERU11W 2CMA101322R1000
Dimensions (mm)
Type B E3 E4
232ERU...W 98 31 70
332ERU...W 98 31 70
432ERU...W 104 32 69
10/45
—
Phase inverters
IP44
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+N+E
416BPI6 5 Red 346...415 50 and 60 416BPI6 2CMA102261R1000 10 0.16
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
10
3P+N+E
5 Red 346...415 50 and 60 432BPI6 2CMA102268R1000 10 0.23
Phase Inverter Panel mounted inlet with unified straight flange. 16A, IP44. Splashproof
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+N+E
5 Red 346...415 50 and 60 416BBI6 2CMA102262R1000 10 0.12
416BBI6
Phase Inverter Panel mounted inlet with unified straight flange. 32A, IP44. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+N+E
5 Red 346...415 50 and 60 432BBI6 2CMA102269R1000 10 0.16
10/46 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Phase inverters
IP44
Phase Inverter surface inlets for wall mounting. 16A, IP44. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
3P+N+E
5 Red 346...415 50 and 60 416BBSI6 2CMA102263R1000 5 0.13
Phase Inverter surface inlet for wall mounting. 32A, IP44. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
10
3P+N+E
5 Red 346...415 50 and 60 432BBSI6 2CMA102270R1000 5 0.13
432BBSI6C 2CMA102271R1000 0.14
Dimensions (mm)
∅D
C Type A B C ØD
416BPI... 136 96 61 6-16
A
432BPI... 156 107 70 11-20.5
A
E F
C
∅H
Dimensions (mm)
Type A B C D E F ØH ØI
D B
416BBI... 75 75 60 60 23 44 5.5 56
432BBI... 75 75 60 60 27 53 5.5 60
∅I
A M
A
E
C M
C E
Dimensions (mm)
D
D
B
∅H
B
∅H
Type A B C D E F G ØH M
F F 416BBSI... 88 88 76 48.5 22 123 84 5.3 M25x1,5
15 º 15 º
432BBSI...C 96 102 84 56 26 146.3 94.3 5.3 M32x1.5
G
G
—
Industrial plugs and sockets
for entertainment applications
— — —
Plugs Connectors Inlets
10
Socket outlet
For wall mounting, Type RS...B For panel mounting with unified For panel mounting with minimized
16 A...32 A, IP4 4 straight flange, Type RU...B angled flange, Type RAM...B
16 A...32 A, IP4 4 16 A...32 A, IP4 4
10/48 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Black plugs and sockets
for entertainment applications
With extensive experience of designing and producing industrial plugs
and sockets, ABB can provide products of high quality, functionality,
reliability and safety. Regardless of the situation, safety of people
should be of highest priority in electrical installations, always.
ABB´s series of black plugs and sockets which are Pin and sleeve configuration according to IEC
very well suited for entertainment applications, standard. Product labels give the information on
such as concerts, cinemas, television studios, and which voltage range the product is intended for.
open-air events. The black series are perfect for The black series assure the high quality level that
both indoor and outdoor use, they will blend into characterizes ABB’s industrial plugs & sockets.
their dark surroundings.
10
10/49
—
Plug in black color
for entertainment applications, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
316EP6B V Hz kg
2P+E
3 Blue 200...250 50 and 60 216EP6B 2CMA103579R1000 10 0.11
Red 380...415 216EP9B 2CMA103598R1000
3P+E
4 Red 380...415 50 and 60 316EP6B 2CMA103584R1000 10 0.16
Blue 200...250 316EP9B 2CMA103585R1000
3P+N+E
5 Red 346...415 50 and 60 416EP6B 2CMA103591R1000 10 0.18
Blue 208...250 416EP9B 2CMA103599R1000
10
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232EP6B 2CMA103581R1000 10 0.21
Red 380...415 232EP9B 2CMA103600R1000
3P+E
4 Red 380...415 50 and 60 332EP6B 2CMA103588R1000 10 0.23
Blue 200...250 332EP9B 2CMA103589R1000
3P+N+E
5 Red 346...415 50 and 60 432EP6B 2CMA103593R1000 10 0.24
Blue 208...250 432EP9B 2CMA103601R1000
Dimensions (mm)
C
Type A B C Dmax
216EP...B 127 62.5 88.5 14
316EP...B 144 74.5 106 17
D max B
416EP...B 144 78 106 17
—
Connector in black color
for entertainment applications, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
316EC6B
2P+E
3 Blue 200...250 50 and 60 216EC6B 2CMA103578R1000 10 0.11
Red 380...415 216EC9B 2CMA103594R1000
3P+E
4 Red 380...415 50 and 60 316EC6B 2CMA103582R1000 10 0.16
Blue 200...250 316EC9B 2CMA103583R1000
3P+N+E
5 Red 346...415 50 and 60 416EC6B 2CMA103590R1000 10 0.17
Blue 208...250 416EC9B 2CMA103595R1000
10
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232EC6B 2CMA103580R1000 10 0.20
Red 380...415 232EC9B 2CMA103596R1000
3P+E
4 Red 380...415 50 and 60 332EC6B 2CMA103586R1000 10 0.22
Blue 200...250 332EC9B 2CMA103587R1000
3P+N+E
5 Red 346...415 50 and 60 432EC6B 2CMA103592R1000 10 0.23
Blue 208...250 432EC9B 2CMA103597R1000
Dimensions (mm)
Type A B Dmax
216EC...B 135.5 74.5 14
B
316EC...B 155 87 17
D max
416EC...B 156 90.5 17
—
Inlets for wall mounting in black color
for entertainment applications, IP44
16 A. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M20 insert for top cable entry.
Rear knock-out cable entry. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3P+E
4 Red 380...415 50 and 60 316BS6B 2CMA101028R1000 10 0.19
Blue 200.250 316BS9B 2CMA101059R1000
3P+N+E
5 Red 346...415 416BS6B 2CMA101029R1000 10 0.20
Blue 208...250 416BS9B 2CMA101060R1000
10
32 A. IP44. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M25 insert for top cable entry.
Rear knock-out cable entry. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232BS6B 2CMA101030R1000 10 0.25
Red 380...415 232BS9B 2CMA101061R1000
3P+E
4 Red 380...415 50 and 60 332BS6B 2CMA101031R1000 10 0.27
Blue 200...250 332BS9B 2CMA101062R1000
3P+N+E
5 Red 346...415 50 and 60 432BS6B 2CMA101032R1000 10 0.29
Blue 208...250 432BS9B 2CMA101063R1000
B
C1 B ØF G ØDmax
ØA Dimensions (mm)
C1 ØF G ØDmax
ØA Type A B C C1 Dmax E1 F G H
216BS...B 23 66 75 54 18/M20 72 5.5 27 110
C 316BS...B 23 79 91 67 18/M20 78 5.5 30 124
H
C 416BS...B 23 79 91 67 18/M20 81 5.5 30 125
H
232BS...B 29 85 111 72 22/M25 94 5.5 34 153
332BS...B 29 85 111 72 22/M25 94 5.5 34 153
432BS...B 29 85 111 72 22/M25 96 5.5 34 154
E1
E1
10/52 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet for wall mounting in black color
for entertainment applications, IP44
16 A. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M20 insert for top cable entry.
Rear knock-out cable entry. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 216RS6B 2CMA101021R1000 10 0.22
3P+E
4 Red 380...415 50 and 60 316RS6B 2CMA101022R1000 10 0.24
Blue 200...250 316RS9B 2CMA101053R1000
3P+N+E
5 Red 346...415 416RS6B 2CMA101023R1000 10 0.26
Blue 208...250 416RS9B 2CMA101054R1000
10
32 A. Splashproof
Housing in plastic (PA). Flexible membrane and metric threaded M25 insert for top cable entry.
Rear knock-out cable entry. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232RS6B 2CMA101024R1000 10 0.30
Red 380...415 232RS9B 2CMA101055R1000
3P+E
4 Red 380...415 50 and 60 332RS6B 2CMA101025R1000 10 0.32
Blue 200...250 332RS9B 2CMA101056R1000
3P+N+E
5 Red 346...415 50 and 60 432RS6B 2CMA101026R1000 10 0.34
Blue 208...250 432RS9B 2CMA101057R1000
E E A A
G G Dimensions (mm)
C1 C1 ØF ØF ØDmax
ØDmax
ØH ØH
Type A B C C1 Dmax E F G H
216RS...B 91 117 75 54 18/M20 66 5.5 27 23
316RS...B 100 132 91 67 18/M20 79 5.5 30 23
C C
B B 416RS...B 104 134 91 67 18/M20 79 5.5 30 23
232RS...B 118 163 111 72 22/M25 85 5.5 34 29
332RS...B 116 163 111 72 22/M25 85 5.5 34 29
432RS...B 121 164 111 72 22/M25 85 5.5 34 29
10/53
—
Socket outlet for panel mounting in black color
for entertainment applications, with unified straight flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216RU6B V Hz kg
2P+E
3 Blue 200...250 50 and 60 216RU6B 2CMA101639R1000 10 0.15
3P+N+E
5 Red 346...415 50 and 60 416RU6B 2CMA101640R1000 10 0.20
32 A. IP44. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
10
V Hz kg
3P+N+E
5 Red 346...415 50 and 60 432RU6B 2CMA101641R1000 10 0.24
D2
Dimensions (mm)
C1
Type C C1 D D2 E E1 H
216RU6B 60-61 60-61 49 75 56 29 79
H
D2 C ØD 416RU6B 60-61 60-61 59 75 60 31 89
432RU6B 60-61 60-61 66 75 71 34 99
Ø 4.2
E1 E
10/54 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet for panel mounting in black color
for entertainment applications, with minimized angled flange IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
316RAM6B
2P+E
3 Blue 200...250 50 and 60 216RAM6B 2CMA100543R1000 10 0.21
Red 380...415 216RAM9B 2CMA101048R1000
3P+E
4 Red 380...415 50 and 60 316RAM6B 2CMA100544R1000 10 0.22
Blue 200...250 316RAM9B 2CMA100873R1000
3P+N+E
5 Red 346...415 50 and 60 416RAM6B 2CMA100545R1000 10 0.24
Blue 208...250 416RAM9B 2CMA101049R1000
10
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232RAM6B 2CMA100546R1000 10 0.21
Red 380...415 232RAM9B 2CMA101050R1000
3P+E
4 Red 380...415 50 and 60 332RAM6B 2CMA100547R1000 10 0.22
Blue 200...250 332RAM9B 2CMA100876R1000
3P+N+E
5 Red 346...415 50 and 60 432RAM6B 2CMA100548R1000 10 0.24
Blue 208...250 432RAM9B 2CMA101051R1000
D2
C1 Dimensions (mm)
D2
Type C C1 D D2 D3 E E1 H
C1
216RAM...B 55 55 63 70 78 53 42 76
D3 C ØD H 316RAM...B 66 66 78 83 89 53 46 85
416RAM...B 66 66 78 83 89 55 48 89
D3 C ØD H232RAM...B 75 75 87 93 99 61 52 98
332RAM...B 75 75 87 93 99 61 52 98
Ø 4.2
432RAM...B 75 75 87 93 99 64 52 101
E1 E
Ø 4.2
E1 E
10/55
—
Industrial plugs and sockets
Fast & Safe
— —
Plugs Connectors
Type QP..., 16 A...32 A, IP4 4 Type QP...W, 16 A...32 A, IP67 Type QC..., 16 A...32 A, IP4 4 Type QC...W, 16 A...32 A, IP67
—
Inlets
10
For wall mounting, Type QBS... For wall mounting, Type QBS...W For panel mounting with unified For panel mounting with unified
16 A...32 A, IP4 4 16 A...32 A, IP67 straight flange, Type QB... straight flange, Type QB...W
16 A...32 A, IP4 4 16 A...32 A, IP67
For panel mounting with straight For panel mounting with unified angled For panel mounting with unified angled
minimized flange, Type Q BM... flange, Type QBA... flange. Type QBA...W
16 A...32 A, IP4 4 16 A...32 A, IP4 4 16 A...32 A, IP67
—
Socket outlet
For wall mounting, Type QRS... For wall mounting, Type QRS...W For panel mounting with unified For panel mounting with unified
16 A...32 A, IP4 4 16A...32 A, IP67 straight flange, Type QR... straight flange, Type QR...W
16 A...32 A, IP4 4 16 A...32 A, IP67
For panel mounting with unified For panel mounting with unified For panel mounting with straight For panel mounting with straight
angled flange, Type QRA... angled flange, Type QRA...W minimized flange, Type QRM... minimized flange, Type QRM...W
16 A...32 A, IP4 4 16 A...32 A, IP67 16 A...32 A, IP4 4 16 A...32 A, IP67
10/56 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Industrial plugs and sockets F FAST
We are now completing our standard offering Fast & Safe is built on spring technology. More
with Fast & Safe in parallel with Easy & Safe. than reducing installation time spring technology
Fast & Safe is a complete offering of 16-32A plugs has high resistance against vibrations and heat
and sockets, both as IP44 and IP67. Instead of a fluctuations.
screw providing contact pressure at the terminal,
10
10/57
—
Plugs
F FAST
IP44
16 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432QP6
3 Yellow 100...130 50 and 60 216QP4 2CMA102579R1000 10 0.15
Blue 200...250 216QP6 2CMA102286R1000
Red 380...415 216QP9 2CMA102858R1000
3P+E
4 Yellow 100...130 50 and 60 316QP4 2CMA102598R1000 10 0.16
Red 380...415 316QP6 2CMA102305R1000
Blue 200...250 316QP9 2CMA102877R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QP4 2CMA102617R1000 10 0.18
10
Red 346...415 416QP6 2CMA102324R1000
Blue 208...250 416QP9 2CMA102896R1000
32 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QP4 2CMA102638R1000 10 0.18
Blue 200...250 232QP6 2CMA102345R1000
Red 380...415 232QP9 2CMA102917R1000
3P+E
4 Yellow 100...130 50 and 60 332QP4 2CMA102690R1000 10 0.20
Red 380...415 332QP6 2CMA102364R1000
Blue 200...250 332QP9 2CMA102936R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QP4 2CMA102709R1000 10 0.24
Red 346...415 432QP6 2CMA102383R1000
Blue 208...250 432QP9 2CMA102955R1000
Dimensions (mm)
Type A B C ØD
∅D
C
216QP... 124 83 47 6-13
316QP... 129 89 53 6-13
416QP... 136 96 61 6-13
A 232QP... 149 100 63 11-20
332QP... 149 100 63 11-20
432QP... 156 107 70 11-20
10/58 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Connectors
F FAST
IP44
16 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216QC6 V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QC4 2CMA102580R1000 10 0.18
Blue 200...250 216QC6 2CMA102287R1000
Red 380...415 216QC9 2CMA102859R1000
3P+E
4 Yellow 100...130 50 and 60 316QC4 2CMA102599R1000 10 0.21
Red 380...415 316QC6 2CMA102306R1000
Blue 200...250 316QC9 2CMA102878R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QC4 2CMA102618R1000 10 0.25
10
32 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QC4 2CMA102639R1000 10 0.25
Blue 200...250 232QC6 2CMA102346R1000
Red 380...415 232QC9 2CMA102918R1000
3P+E
4 Yellow 100...130 50 and 60 332QC4 2CMA102691R1000 10 0.26
Red 380...415 332QC6 2CMA102365R1000
Blue 200...250 332QC9 2CMA102937R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QC4 2CMA102710R1000 10 0.26
Red 346...415 432QC6 2CMA102384R1000
Blue 208...250 432QC9 2CMA102956R1000
Dimensions (mm)
C
Type A B C ØD
∅D
216QC... 128 83 72 6-13
316QC... 135 89 78 6-13
416QC... 142 96 87 6-13
A
232QC... 156 100 91 11-20
332QC... 156 100 91 11-20
432QC... 162 107 97 11-20
10/59
—
Inlets
F FAST
for wall mounting, IP44
16 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QBS4 2CMA102587R1000 5 0.22
416QBS6 Yellow 100...130 216QBS4C 2CMA102588R1000 0.25
Blue 200...250 216QBS6 2CMA102294R1000 0.22
Blue 200...250 216QBS6C 2CMA102295R1000 0.25
Red 380...415 216QBS9 2CMA102866R1000 0.22
Red 380...415 216QBS9C 2CMA102867R1000 0.25
3P+E
4 Yellow 100...130 50 and 60 316QBS4 2CMA102606R1000 5 0.22
Yellow 100...130 316QBS4C 2CMA102607R1000 0.25
10
Red 380...415 316QBS6 2CMA102313R1000 0.22
Red 380...415 316QBS6C 2CMA102314R1000 0.25
Blue 200...250 316QBS9 2CMA102885R1000 0.22
Blue 200...250 316QBS9C 2CMA102886R1000 0.25
3P+N+E
5 Yellow 100...130 50 and 60 416QBS4 2CMA102626R1000 5 0.22
Yellow 100...130 416QBS4C 2CMA102627R1000 0.25
Red 346...415 416QBS6 2CMA102333R1000 0.22
Red 346...415 416QBS6C 2CMA102334R1000 0.25
Blue 208...250 416QBS9 2CMA102905R1000 0.22
Blue 208...250 416QBS9C 2CMA102906R1000 0.25
A M A
Dimensions (mm)
E
C E M
C
D
D
Type A B C D E F G ØH M
∅H ∅H
B B
G 15 º
G
416QBS...C 88 88 76 48.5 22 123.3 84.3 5.3 M25x1.5
Type .32QBS... Type.32QBS...C
10/60 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
F FAST
for wall mounting, IP44
32 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QBS4 2CMA102646R1000 5 0.22
Yellow 100...130 232QBS4C 2CMA102647R1000 0.25
432QBS6
Blue 200...250 232QBS6 2CMA102353R1000 0.22
Blue 200...250 232QBS6C 2CMA102354R1000 0.25
Red 380...415 232QBS9 2CMA102925R1000 0.22
Red 380...415 232QBS9C 2CMA102926R1000 0.25
3P+E
4 Yellow 100...130 50 and 60 332QBS4 2CMA102698R1000 5 0.29
Yellow 100...130 332QBS4C 2CMA102699R1000 0.31
10
3P+N+E
5 Yellow 100...130 50 and 60 432QBS4 2CMA102718R1000 5 0.31
Yellow 100...130 432QBS4C 2CMA102719R1000 0.35
Red 346...415 432QBS6 2CMA102392R1000 0.31
Red 346...415 432QBS6C 2CMA102393R1000 0.35
Blue 208...250 432QBS9 2CMA102964R1000 0.31
Blue 208...250 432QBS9C 2CMA102965R1000 0.35
A M A
Dimensions (mm)
E
C E M
C
D
D
Type A B C D E F G ØH M
∅H ∅H
B B
G 15 º
G
432QBS...C 96 102 84 56 26.3 146.3 94 5.3 M32x1.5
Type .32QBS... Type.32QBS...C
10/61
—
Inlets
F FAST
for panel mounting with unified straight flange, IP44
16 A. Splashproof
Housing in plastic (PA). Fast connection. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432QB6
3P+N+E
5 Yellow 100...130 50 and 60 416QB4 2CMA102624R1000 10 0.13
Red 346...415 416QB6 2CMA102331R1000
Blue 208...250 416QB9 2CMA102903R1000
32 A. Splashproof
Housing in plastic (PA). Fast connection.Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
10
V Hz kg
3P+N+E
5 Yellow 100...130 50 and 60 432QB4 2CMA102716R1000 10 0.17
Red 346...415 432QB6 2CMA102390R1000
Blue 208...250 432QB9 2CMA102962R1000
A
E F
C
∅H
D B
∅I
Dimensions (mm)
Type A B C D E F ØH ØI
416QB... 75 75 60 60 23 44 5.5 56
432QB... 75 75 60 60 27 53 5.5 60
10/62 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
F FAST
for panel mounting with unified angled flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QBA4 2CMA102586R1000 10 0.15
Blue 200...250 216QBA6 2CMA102293R1000
432QBA6
Red 380...415 216QBA9 2CMA102865R1000
3P+E
4 Yellow 100...130 50 and 60 316QBA4 2CMA102605R1000 10 0.18
Red 380...415 316QBA6 2CMA102312R1000
Blue 200...250 316QBA9 2CMA102884R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QBA4 2CMA102625R1000 10 0.22
10
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QBA4 2CMA102645R1000 10 0.17
Blue 200...250 232QBA6 2CMA102352R1000
Red 380...415 232QBA9 2CMA102924R1000
3P+E
4 Yellow 100...130 50 and 60 332QBA4 2CMA102697R1000 10 0.20
Red 380...415 332QBA6 2CMA102371R1000
Blue 200...250 332QBA9 2CMA102943R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QBA4 2CMA102717R1000 10 0.48
Red 346...415 432QBA6 2CMA102391R1000
Blue 208...250 432QBA9 2CMA102963R1000
A
C E
∅H
Dimensions (mm)
Type A B C D E F ØH ØI
D B
F
216QBA... 85 85 70 70 106 85 6.3 50
316QBA... 85 85 70 70 112 88 6.3 50
416QBA... 85 85 70 70 117 94 6.3 50
10 º
∅I
232QBA... 85 85 70 70 126 96 6.3 50
332QBA... 85 85 70 70 126 96 6.3 50
432QBA... 85 85 70 70 133 102 6.3 50
10/63
—
Inlets
F FAST
for panel mounting with straight minimized flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216QBM6
2P+E
3 Yellow 100...130 50 and 60 216QBM4 2CMA102585R1000 10 0.10
Blue 200...250 216QBM6 2CMA102292R1000
Red 380...415 216QBM9 2CMA102864R1000
3P+E
4 Yellow 100...130 50 and 60 316QBM4 2CMA102604R1000 10 0.13
Red 380...415 316QBM6 2CMA102311R1000
Blue 200...250 316QBM9 2CMA102883R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QBM4 2CMA102623R1000 10 0.13
10
Red 346...415 416QBM6 2CMA102330R1000
Blue 208...250 416QBM9 2CMA102902R1000
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QBM4 2CMA102644R1000 10 0.11
Blue 200...250 232QBM6 2CMA102351R1000
Red 380...415 232QBM6 2CMA102923R1000
3P+E
4 Yellow 100...130 50 and 60 332QBM4 2CMA102696R1000 10 0.15
Red 380...415 332QBM6 2CMA102370R1000
Blue 200...250 332QBM9 2CMA102942R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QBM4 2CMA102715R1000 10 0.17
Red 346...415 432QBM6 2CMA102389R1000
Blue 208...250 432QBM9 2CMA102961R1000
A
E F
∅H
C
Dimensions (mm)
Type A B C D E F ØH ØI
216QBM... 70 70 56 56 23 44 5.5 44
D B
316QBM... 70 70 56 56 23 44 5.5 52
416QBM... 70 70 56 56 23 44 5.5 56
232QBM... 70 70 56 56 27 53 5.5 56
∅I 332QBM... 70 70 56 56 27 53 5.5 56
432QBM... 70 70 56 56 27 53 5.5 60
10/64 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
F FAST
for wall mounting, IP44
16 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QRS4 2CMA102584R1000 10 0.25
432QRS6
Blue 200...250 216QRS6 2CMA102291R1000
Red 380...415 216QRS9 2CMA102863R1000
3P+E
4 Yellow 100...130 50 and 60 316QRS4 2CMA102603R1000 10 0.27
Red 380...415 316QRS6 2CMA102310R1000
Blue 200...250 316QRS9 2CMA102882R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QRS4 2CMA102622R1000 10 0.29
10
32 A. Splashproof
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QRS4 2CMA102643R1000 10 0.30
Blue 200...250 232QRS6 2CMA102350R1000
Red 380...415 232QRS9 2CMA102922R1000
3P+E
4 Yellow 100...130 50 and 60 332QRS4 2CMA102695R1000 10 0.33
Red 380...415 332QRS6 2CMA102369R1000
Blue 200...250 332QRS9 2CMA102941R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QRS4 2CMA102714R1000 10 0.36
Red 346...415 432QRS6 2CMA102388R1000
Blue 208...250 432QRS9 2CMA102960R1000
A M
E
C
Dimensions (mm)
D
Type A B C D E F G ØH M
∅H
B
216QRS... 75 80 64 43 20 121 88 5.3 M20x1.5
F
316QRS... 88 88 76 48.5 22 128 96 5.3 M25x1.5
416QRS... 88 88 76 48.5 22 128 103 5.3 M25x1.5
232QRS... 88 88 76 48.5 22 139 106 5.3 M25x1.5
332QRS... 88 88 76 48.5 22 139 106 5.3 M25x1.5
15 º 432QRS... 88 102 84 56 26 152 113 5.3 M32x1.5
G
10/65
—
Socket outlet
F FAST
for panel mounting with unified straight flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216QR6 V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QR4 2CMA102582R1000 10 0.11
Blue 200...250 216QR6 2CMA102289R1000
Red 380...415 216QR9 2CMA102861R1000
3P+E
4 Yellow 100...130 50 and 60 316QR4 2CMA102601R1000 10 0.13
Red 380...415 316QR6 2CMA102308R1000
Blue 200...250 316QR9 2CMA102880R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QR4 2CMA102620R1000 10 0.15
10
Red 346...415 416QR6 2CMA102327R1000
Blue 208...250 416QR9 2CMA102899R1000
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QR4 2CMA102641R1000 10 0.15
Blue 200...250 232QR6 2CMA102348R1000
Red 380...415 232QR9 2CMA102920R1000
3P+E
4 Yellow 100...130 50 and 60 332QR4 2CMA102693R1000 10 0.16
Red 380...415 332QR6 2CMA102367R1000
Blue 200...250 332QR9 2CMA102939R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QR4 2CMA102712R1000 10 0.18
Red 346...415 432QR6 2CMA102386R1000
Blue 208...250 432QR9 2CMA102958R1000
G
E F
Dimensions (mm)
A
C
∅H
Type A B C D E F G ØH ØI K
K 216QR... 75 75 60 60 24 49 95 5.5 44 86
D B
316QR... 75 75 60 60 24 49 102 5.5 49 90
416QR... 75 75 60 60 24 49 110 5.5 56 94
∅I
232QR... 75 75 60 60 30 58 122 5.5 56 98
332QR... 75 75 60 60 30 58 122 5.5 56 98
432QR... 75 75 60 60 30 58 128 5.5 60 105
10/66 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet
F FAST
for panel mounting with unified angled flange, IP44
16 A. Splashproof
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432QRA6 2P+E
3 Yellow 100...130 50 and 60 216QRA4 2CMA102583R1000 10 0.15
Blue 200...250 216QRA6 2CMA102290R1000
Red 380...415 216QRA9 2CMA102862R1000
3P+E
4 Yellow 100...130 50 and 60 316QRA4 2CMA102602R1000 10 0.16
Red 380...415 316QRA6 2CMA102309R1000
Blue 200...250 316QRA9 2CMA102881R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QRA4 2CMA102621R1000 10 0.16
10
32 A. Splashproof
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QRA4 2CMA102642R1000 10 0.20
Blue 200...250 232QRA6 2CMA102349R1000
Red 380...415 232QRA9 2CMA102921R1000
3P+E
4 Yellow 100...130 50 and 60 332QRA4 2CMA102694R1000 10 0.22
Red 380...415 332QRA6 2CMA102368R1000
Blue 200...250 332QRA9 2CMA102940R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QRA4 2CMA102713R1000 10 0.40
Red 346...415 432QRA6 2CMA102387R1000
Blue 208...250 432QRA9 2CMA102959R1000
A E F
C
∅H
Dimensions (mm)
º
20
M D B
Type A B C D E F G ØH K M
G
216QRA... 83 90 70 76 37 43 90 5 52 65
316QRA... 83 90 70 76 37 45 90 5 56 68
K 416QRA... 83 90 70 76 37 47 90 5 62 72
232QRA... 83 90 70 76 43 54 98 5 66 76
332QRA... 83 90 70 76 43 54 98 5 66 76
432QRA... 83 90 70 76 49 51 100 5 72 82
10/67
—
Socket outlet
F FAST
for panel mounting with straight minimized flange, IP44
16 A. Splashproof
Housing in plastic (PA). Fast connection. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216QRM6 V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QRM4 2CMA102581R1000 10 0.11
Blue 200...250 216QRM6 2CMA102288R1000
Red 380...415 216QRM9 2CMA102860R1000
3P+E
4 Yellow 100...130 50 and 60 316QRM4 2CMA102600R1000 10 0.13
Red 380...415 316QRM6 2CMA102307R1000
Blue 200...250 316QRM9 2CMA102879R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QRM4 2CMA102619R1000 10 0.15
10
Red 346...415 416QRM6 2CMA102326R1000
Blue 208...250 416QRM9 2CMA102898R1000
32 A. Splashproof
Housing in plastic (PA). Fast connection.Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QRM4 2CMA102640R1000 10 0.14
Blue 200...250 232QRM6 2CMA102347R1000
Red 380...415 232QRM9 2CMA102919R1000
3P+E
4 Yellow 100...130 50 and 60 332QRM4 2CMA102692R1000 10 0.15
Red 380...415 332QRM6 2CMA102366R1000
Blue 200...250 332QRM9 2CMA102938R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QRM4 2CMA102711R1000 10 0.18
Red 346...415 432QRM6 2CMA102385R1000
Blue 208...250 432QRM9 2CMA102957R1000
G
E F
Dimensions (mm)
A
C
∅H
Type A B C D E F G ØH ØI K
K 216QRM... 70 70 56 56 24 49 95 5.5 44 86
D B
316QRM... 70 70 56 56 24 49 102 5.5 49 90
416QRM... 70 70 56 56 24 49 110 5.5 56 94
∅I 232QRM... 70 70 56 56 30 58 122 5.5 56 98
332QRM... 70 70 56 56 30 58 122 5.5 56 98
432QRM... 70 70 56 56 30 58 128 5.5 60 104
10/68 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
F FAST
IP67
16 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432QP6W
2P+E
3 Yellow 100...130 50 and 60 216QP4W 2CMA102589R1000 10 0.17
Blue 200...250 216QP6W 2CMA102296R1000
Red 380...415 216QP9W 2CMA102868R1000
3P+E
4 Yellow 100...130 50 and 60 316QP4W 2CMA102608R1000 10 0.19
Red 380...415 316QP6W 2CMA102315R1000
Blue 200...250 316QP9W 2CMA102887R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QP4W 2CMA102628R1000 10 0.23
10
32 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QP4W 2CMA102648R1000 10 0.23
Blue 200...250 232QP6W 2CMA102355R1000
Red 380...415 232QP9W 2CMA102927R1000
3P+E
4 Yellow 100...130 50 and 60 332QP4W 2CMA102700R1000 10 0.25
Red 380...415 332QP6W 2CMA102374R1000
Blue 200...250 332QP9W 2CMA102946R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QP4W 2CMA102720R1000 10 0.29
Red 346...415 432QP6W 2CMA102394R1000
Blue 208...250 432QP9W 2CMA102966R1000
Dimensions (mm)
Type A B C ØD
∅D C 216QP... 124 83 72 6-13
316QP... 129 89 81 6-13
416QP... 136 96 89 6-13
232QP... 149 100 93 11-20
A
332QP... 149 100 93 11-20
432QP... 156 107 102 11-20
10/69
—
Connectors
F FAST
IP67
16 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432QC6W
3 Yellow 100...130 50 and 60 216QC4W 2CMA102590R1000 10 0.20
Blue 200...250 216QC6W 2CMA102297R1000
Red 380...415 216QC9W 2CMA102869R1000
3P+E
4 Yellow 100...130 50 and 60 316QC4W 2CMA102609R1000 10 0.25
Red 380...415 316QC6W 2CMA102316R1000
Blue 200...250 316QC9W 2CMA102888R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QC4W 2CMA102629R1000 10 0.27
10
Red 346...415 416QC6W 2CMA102336R1000
Blue 208...250 416QC9W 2CMA102908R1000
32 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QC4W 2CMA102649R1000 10 0.29
Blue 200...250 232QC6W 2CMA102356R1000
Red 380...415 232QC9W 2CMA102928R1000
3P+E
4 Yellow 100...130 50 and 60 332QC4W 2CMA102701R1000 10 0.31
Red 380...415 332QC6W 2CMA102375R1000
Blue 200...250 332QC9W 2CMA102947R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QC4W 2CMA102721R1000 10 0.32
Red 346...415 432QC6W 2CMA102395R1000
Blue 208...250 432QC9W 2CMA102967R1000
B
Dimensions (mm)
Type A B C ØD
C 216QC...W 137 83 82 6-13
∅D
316QC...W 143 89 89 6-13
416QC...W 150 96 99 6-13
232QC...W 166 100 102 11-20
332QC...W 166 100 102 11-20
A
—
Inlets
F FAST
for wall mounting, IP67
16 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216QBS6W 3 Yellow 100...130 50 and 60 216QBS4W 2CMA102597R1000 10 0.23
Blue 200...250 216QBS6W 2CMA102304R1000
Red 380...415 216QBS9W 2CMA102876R1000
3P+E
4 Yellow 100...130 50 and 60 316QBS4W 2CMA102616R1000 10 0.29
Red 380...415 316QBS6W 2CMA102323R1000
Blue 200...250 316QBS9W 2CMA102895R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QBS4W 2CMA102637R1000 10 0.30
10
32 A. Watertight
Housing in plastic (PA). Fast connnection. Cable entry with compression gland. Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QBS4W 2CMA102689R1000 10 0.24
Blue 200...250 232QBS6W 2CMA102363R1000
Red 380...415 232QBS9W 2CMA102935R1000
3P+E
4 Yellow 100...130 50 and 60 332QBS4W 2CMA102708R1000 10 0.26
Red 380...415 332QBS6W 2CMA102382R1000
Blue 200...250 332QBS9W 2CMA102954R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QBS4W 2CMA102727R1000 10 0.37
Red 346...415 432QBS6W 2CMA102401R1000
Blue 208...250 432QBS9W 2CMA102973R1000
A M
C E
K
∅H
Dimensions (mm)
D
Type A B C D E F G K ØH M
B
—
Inlets
F FAST
for panel mounting with unified straight flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216QB6W
2P+E
3 Yellow 100...130 50 and 60 216QB4W 2CMA102595R1000 10 0.12
Blue 200...250 216QB6W 2CMA102302R1000
Red 380...415 216QB9W 2CMA102874R1000
3P+E
4 Yellow 100...130 50 and 60 316QB4W 2CMA102614R1000 10 0.14
Red 380...415 316QB6W 2CMA102321R1000
Blue 200...250 316QB9W 2CMA102893R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QB4W 2CMA102635R1000 10 0.18
10
Red 346...415 416QB6W 2CMA102342R1000
Blue 208...250 416QB9W 2CMA102914R1000
32 A. Watertight
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QB4W 2CMA102687R1000 10 0.20
Blue 200...250 232QB6W 2CMA102361R1000
Red 380...415 232QB9W 2CMA102933R1000
3P+E
4 Yellow 100...130 50 and 60 332QB4W 2CMA102706R1000 10 0.22
Red 380...415 332QB6W 2CMA102380R1000
Blue 200...250 332QB9W 2CMA102952R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QB4W 2CMA102725R1000 10 0.24
Red 346...415 432QB6W 2CMA102399R1000
Blue 208...250 432QB9W 2CMA102971R1000
A
C E F
Dimensions (mm)
∅H
Type A B C D E F G ØH ØI
216QB...W 83 90 70 76 17 52 90 5.5 65
B G
D
316QB...W 83 90 70 76 17 52 90 5.5 65
416QB...W 83 90 70 76 17 52 90 5.5 65
232QB...W 83 90 70 76 21 61 93 5.5 65
332QB...W 83 90 70 76 21 61 93 5.5 65
∅I
432QB...W 83 90 70 76 21 61 102 5.5 65
10/72 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets
F FAST
for panel mounting with unified angled flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1...2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432QBA6W 3 Yellow 100...130 50 and 60 216QBA4W 2CMA102596R1000 10 0.12
Blue 200...250 216QBA6W 2CMA102303R1000
Red 380...415 216QBA9W 2CMA102875R1000
3P+E
4 Yellow 100...130 50 and 60 316QBA4W 2CMA102615R1000 10 0.22
Red 380...415 316QBA6W 2CMA102322R1000
Blue 200...250 316QBA9W 2CMA102894R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QBA4W 2CMA102636R1000 10 0.24
10
32 A. Watertight
Housing in plastic (PA). Cable area 2.5...6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QBA4W 2CMA102688R1000 10 0.18
Blue 200...250 232QBA6W 2CMA102362R1000
Red 380...415 232QBA9W 2CMA102934R1000
3P+E
4 Yellow 100...130 50 and 60 332QBA4W 2CMA102707R1000 10 0.20
Red 380...415 332QBA6W 2CMA102381R1000
Blue 200...250 332QBA9W 2CMA102953R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QBA4W 2CMA102726R1000 10 0.25
Red 346...415 432QBA6W 2CMA102400R1000
Blue 208...250 432QBA9W 2CMA102972R1000
A
Dimensions (mm)
C E
∅H
Type A B C D E F G ØH K M
216QBA...W 83 90 70 76 37 50 103 5 52 65
D B 316QBA...W 83 90 70 76 37 52 109 5 56 68
F
416QBA...W 83 90 70 76 37 55 119 5 62 72
232QBA...W 83 90 70 76 43 62 125 5 66 76
332QBA...W 83 90 70 76 43 62 125 5 66 76
10
∅I
432QBA...W 83 90 70 76 49 59 133 5 72 82
10/73
—
Socket outlet
F FAST
for wall mounting, IP67
16 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216QRS4W 2CMA102593R1000 5 0.25
Blue 200...250 216QRS6W 2CMA102300R1000
232QRS6W
Red 380...415 216QRS9W 2CMA102872R1000
3P+E
4 Yellow 100...130 50 and 60 316QRS4W 2CMA102612R1000 5 0.28
Red 380...415 316QRS6W 2CMA102319R1000
Blue 200...250 316QRS9W 2CMA102891R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QRS4W 2CMA102633R1000 10 0.36
10
Red 346...415 416QRS6W 2CMA102340R1000
Blue 208...250 416QRS9W 2CMA102912R1000
32 A. Watertight
Housing in plastic (PA). Fast connection. Cable entry with compression gland. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QRS4W 2CMA102652R1000 5 0.38
Blue 200...250 232QRS6W 2CMA102359R1000
Red 380...415 232QRS9W 2CMA102931R1000
3P+E
4 Yellow 100...130 50 and 60 332QRS4W 2CMA102704R1000 5 0.39
Red 380...415 332QRS6W 2CMA102378R1000
Blue 200...250 332QRS9W 2CMA102950R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QRS4W 2CMA102724R1000 5 0.42
Red 346...415 432QRS6W 2CMA102398R1000
Blue 208...250 432QRS9W 2CMA102970R1000
A
M
C E
Dimensions (mm)
K
D ∅H
Type A B C D E F G K ØH M
B
G
10/74 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Sockets outlet
F FAST
for panel mounting with unified straight flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432QR6W 2P+E
3 Yellow 100...130 50 and 60 216QR4W 2CMA102591R1000 10 0.13
Blue 200...250 216QR6W 2CMA102298R1000
Red 380...415 216QR9W 2CMA102870R1000
3P+E
4 Yellow 100...130 50 and 60 316QR4W 2CMA102610R1000 10 0.14
Red 380...415 316QR6W 2CMA102317R1000
Blue 200...250 316QR9W 2CMA102889R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QR4W 2CMA102631R1000 10 0.15
10
32 A. Watertight
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QR4W 2CMA102650R1000 10 0.18
Blue 200...250 232QR6W 2CMA102357R1000
Red 380...415 232QR9W 2CMA102929R1000
3P+E
4 Yellow 100...130 50 and 60 332QR4W 2CMA102702R1000 10 0.25
Red 380...415 332QR6W 2CMA102376R1000
Blue 200...250 332QR9W 2CMA102948R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QR4W 2CMA102722R1000 10 0.28
Red 346...415 432QR6W 2CMA102396R1000
Blue 208...250 432QR9W 2CMA102968R1000
E F
Dimensions (mm)
A
Type A B C D E F G ØH ØI K
∅H
C
216QR... 75 75 60 60 24 57 102 5.5 44 108
K 316QR... 75 75 60 60 24 58 109 5.5 49 114
D B
416QR... 75 75 60 60 24 58 117 5.5 56 126
232QR... 75 75 60 60 30 67 128 5.5 56 132
332QR... 75 75 60 60 30 67 128 5.5 56 132
∅I
432QR... 75 75 60 60 30 67 133 5.5 60 140
10/75
—
Socket outlet
F FAST
for panel mounting with unified angled flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216QRA6W
3 Yellow 100...130 50 and 60 216QRA4W 2CMA102592R1000 10 0.17
Blue 200...250 216QRA6W 2CMA102299R1000
Red 380...415 216QRA9W 2CMA102871R1000
3P+E
4 Yellow 100...130 50 and 60 316QRA4W 2CMA102611R1000 10 0.19
Red 380...415 316QRA6W 2CMA102318R1000
Blue 200...250 316QRA9W 2CMA102890R1000
3P+N+E
5 Yellow 100...130 50 and 60 416QRA4W 2CMA102632R1000 10 0.23
10
Red 346...415 416QRA6W 2CMA102339R1000
Blue 208...250 416QRA9W 2CMA102911R1000
32 A. Watertight
Housing in plastic (PA). Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232QRA4W 2CMA102651R1000 10 0.24
Blue 200...250 232QRA6W 2CMA102358R1000
Red 380...415 232QRA9W 2CMA102930R1000
3P+E
4 Yellow 100...130 50 and 60 332QRA4W 2CMA102703R1000 10 0.26
Red 380...415 332QRA6W 2CMA102377R1000
Blue 200...250 332QRA9W 2CMA102949R1000
3P+N+E
5 Yellow 100...130 50 and 60 432QRA4W 2CMA102723R1000 10 0.29
Red 346...415 432QRA6W 2CMA102397R1000
Blue 208...250 432QRA9W 2CMA102969R1000
E F
A E F
C
∅H
A 20
º
Dimensions (mm)
C
∅H º
20
M
G Type A B C D E F G ØH K M
D B
M
D B
G
216QRA...W 83 90 70 76 37 50 106 5 52 65
316QRA...W 83 90 70 76 37 52 109 5 56 68
K 416QRA...W 83 90 70 76 37 55 119 5 62 72
K
232QRA...W 83 90 70 76 43 62 125 5 66 76
332QRA...W 83 90 70 76 43 62 125 5 66 76
432QRA...W 83 90 70 76 49 59 133 5 72 82
10/76 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Sockets outlet
F FAST
for panel mounting with minimized straight flange, IP67
16 A. Watertight
Housing in plastic (PA). Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
416QRM6W
3P+N+E
5 Yellow 100...130 50 and 60 416QRM4W 2CMA102630R1000 10 0.17
Red 346...415 416QRM6W 2CMA102337R1000
Blue 208...250 416QRM9W 2CMA102909R1000
E F
C
∅H
10
D B
∅I
Dimensions (mm)
Type A B C D E F G ØH ØI K
416QRM...W 70 70 56 56 19 57 117 5.5 56 125
10/7 7
—
Industrial plugs and sockets
Critical & Safe
—
Switched interlocked socket outlet
Heavy duty, Type MVS...WH Heavy duty, Type MVS...WH Vertical with protection, Vertical, Type MVS...
16 A...32A, IP67 63A...125 A, IP67 Type MPR..., 16A...32 A, IP4 4 16A...32 A, IP4 4
10
Vertical, Type MVS...W Metal enclosed, Type MM Metal enclosed, Type MM... Metal enclosed, Type MM...
16 A...32A, IP67 125 A, IP4 4 16 A...32 A, IP4 4 63 A, IP4 4
Horizontal, Type MHS... Horizontal, Type MHS Horizontal, Type MHS...W Horizontal, Type MHS..W
16 A...32 A, IP4 4 63 A, IP4 4 16A...32 A, IP67 63 A, IP67
—
Surface socket outlet
—
Industrial plugs and sockets
Critical & Safe
Our new industrial plugs and sockets complements ABB’s strong
low-voltage offer. These plugs and sockets are part of Critical & Safe.
Critical & Safe is a product range suitable for general use in most
applications.
“Critical & Safe is the range for applications with The housing is made of PBT or aluminum. PBT is
high demands on safety, durability and perfor- a tough plastic material that withstands heavy-
mance. The product range is perfect for applica- duty usage and most chemicals found in indus-
tions with frequent connection/disconnection, trial environments. The aluminum housing is
and to use in public areas. Switch interlock sys- a mix of aluminium and silicon called silumin,
tem provides high product and personal safety, which gives an excellent protection against corro-
thanks to the mechanism it is not possible to turn sion while being robust and tough against impact
on the product if a correct plug is not engaged, and sunlight.”
which in turn means that the risk of personal
10
—
Switched interlocked socket outlets
Heavy duty
16 A. IP67/IP69. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 25+32 mm on top and drill marks on bottom.
Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
416MVS6WH 3 Grey AC 216MVS1WH 2CMA163255R1000 1 1.75
Yellow 100...130 50 and 60 216MVS4WH 2CMA163256R1000
Blue 200...250 216MVS6WH 2CMA163257R1000
Red 380...415 216MVS9WH 2CMA163258R1000
Grey transf 216MVS12WH 2CMA163259R1000
3P+E
4 Grey AC 316MVS1WH 2CMA163261R1000 1 1.79
Yellow 100...130 50 and 60 316MVS4WH 2CMA163262R1000
Black 600...690 316MVS5WH 2CMA163263R1000
10
Red 380...415 316MVS6WH 2CMA163264R1000
Black 480...500 316MVS7WH 2CMA163265R1000
Blue 200...250 316MVS9WH 2CMA163266R1000
Green > 50 V~ 100...300 316MVS10WH 2CMA163267R1000
Red 440...460 60 316MVS11WH 2CMA163268R1000
3P+N+E
5 Grey AC 416MVS1WH 2CMA163270R1000 1 1.83
Green > 50 V~ >300...500 416MVS2WH 2CMA163271R1000
Red 346...415 50 and 60 416MVS6WH 2CMA163272R1000
Black 480...500 416MVS7WH 2CMA101713R1000
Blue 208...250 416MVS9WH 2CMA163273R1000
B
72,5
253
A
378
C
125
145
Dimensions (mm)
Type A B C D
216MVS...WH 255 160 306 205
316MVS...WH 255 160 306 205
416MVS...WH 255 160 306 205
10/80 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Heavy duty
32 A. IP67/IP69. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 25+32 mm on top and drill marks on bottom.
Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432MVS6WH 3 Grey AC 232MVS1WH 2CMA163275R1000 1 1.87
Grey > 50...250 DC 232MVS3WH 2CMA105985R1000
Yellow 100...130 50 and 60 232MVS4WH 2CMA105108R1000
Blue 200...250 232MVS6WH 2CMA163276R1000
Red 380...415 232MVS9WH 2CMA105109R1000
Grey transf. 232MVS12WH 2CMA105110R1000
3P+E
4 Grey AC 332MVS1WH 2CMA163277R1000 1 1.91
Red 380/440 50/60 332MVS3WH 2CMA100662R1000
10
3P+N+E
5 Grey AC 432MVS1WH 2CMA163284R1000 1 1.95
Green > 50 V~ >300...500 432MVS2WH 2CMA105114R1000
Yellow 100...130 50 and 60 432MVS4WH 2CMA105115R1000
Red 346...415 432MVS6WH 2CMA163285R1000
Black 480...500 432MVS7WH 2CMA163286R1000
Blue 208...250 432MVS9WH 2CMA101701R1000
Red 440...460 60 432MVS11WH 2CMA105117R1000
- The switch handle is padlockable (5-8 mm shackle)
- The switch insert can be equipped with an auxiliary contact, (see page 100)
A
C
D
Dimensions (mm)
Type A B C D
232MVS...WH 255 160 306 205
332MVS...WH 255 160 306 205
432MVS...WH 255 160 306 205
10/81
—
Switched interlocked socket outlets
Heavy duty
63 A. IP67/IP69. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 40+50 mm on top and drill marks on bottom.
Cable area 6...25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 263MVS1WH 2CMA162831R1000 1 3.50
Yellow 100...130 50 and 60 263MVS4WH 2CMA162827R1000
Blue 200...250 263MVS6WH 2CMA162828R1000
Red 380...415 263MVS9WH 2CMA162829R1000
463MVS6WH
3P+E
4 Grey AC 363MVS1WH 2CMA162841R1000 1 3.50
Yellow 100...130 50 and 60 363MVS4WH 2CMA162834R1000
Black 600...690 363MVS5WH 2CMA162835R1000
Red 380...415 363MVS6WH 2CMA162836R1000
10
Black 480...500 363MVS7WH 2CMA162837R1000
Blue 200...250 363MVS9WH 2CMA162838R1000
Red 440...460 60 363MVS11WH 2CMA162840R1000
3P+N+E
5 Grey AC 463MVS1WH 2CMA162849R1000 1 3.60
Yellow 100...130 50 and 60 463MVS4WH 2CMA162844R1000
Red 346...415 463MVS6WH 2CMA162845R1000
Black 600...690 463MVS5WH 2CMA162805R1000
Black 480...500 463MVS7WH 2CMA162846R1000
Blue 208...250 463MVS9WH 2CMA162847R1000
Red 440...460 60 463MVS11WH 2CMA162848R1000
- The switch handle is padlockable (5-8 mm shackle)
- The switch insert can be equipped with an auxiliary contact, (see page 100)
B
72,5
253
A C
378
125
D 145
Dimensions (mm)
Type A B C D
263MVS...WH 408 175 463 241
363MVS...WH 408 175 463 241
463MVS...WH 408 175 463 241
10/82 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Heavy duty
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 2125MVS1WH 2CMA162740R1000 1 4.20
Yellow 100...130 50 and 60 2125MVS4WH 2CMA162738R1000
Blue 200...250 2125MVS6WH 2CMA162739R1000
Red 380...415 2125MVS9WH 2CMA101837R1000
4125MVS6WH
3P+E
4 Grey AC 3125MVS1WH 2CMA162746R1000 1 4.40
Yellow 100...130 50 and 60 3125MVS4WH 2CMA162741R1000
Red 380...415 3125MVS6WH 2CMA162742R1000
Black 600...690 3125MVS5WH 2CMA162747R1000
10
3P+N+E
5 Grey AC 4125MVS1WH 2CMA162796R1000 1 4.50
Yellow 100...130 50 and 60 4125MVS4WH 2CMA162791R1000
Red 346...415 4125MVS6WH 2CMA162792R1000
Black 600...690 4125MVS5WH 2CMA162797R1000
Black 480...500 4125MVS7WH 2CMA162793R1000
Blue 208...250 4125MVS9WH 2CMA162794R1000
Red 440...460 60 4125MVS11WH 2CMA162795R1000
- The switch handle is padlockable (5-8 mm shackle)
- The switch insert can be equipped with an auxiliary contact, (see page 100)
B
72,5
253
A C
378
125
D 145
Dimensions (mm)
Type A B C D
2125MVS...WH 408 175 463 241
3125MVS...WH 408 175 463 241
4125MVS...WH 408 175 463 241
10/83
—
Switched interlocked socket outlets
Metal enclosed
16 A. IP44. Splashproof
Housing in aluminum. Cable entry 2 x M25 + 2 x M32. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
416MM6 3P+E
4 Grey AC 316MM1 2CMA167980R1000 1 1.30
Yellow 100...130 50 and 60 316MM4 2CMA167973R1000
Black 600...690 316MM5 2CMA167974R1000
Red 380...415 316MM6 2CMA167975R1000
Black 480...500 316MM7 2CMA167976R1000
Blue 200...250 316MM9 2CMA167977R1000
Green > 50 V~ 100...300 316MM10 2CMA167978R1000
Red 440...460 60 316MM11 2CMA167979R1000
3P+N+E
10
5 Grey AC 416MM1 2CMA167988R1000 1 1.32
Green > 50 V~ >300...500 416MM2 2CMA167981R1000
Black 600...690 50 and 60 416MM5 2CMA126695R1000
Red 346...415 416MM6 2CMA167984R1000
Blue 208...250 416MM9 2CMA167986R1000
Red 440...460 60 416MM11 2CMA167987R1000
- The switch handle is padlockable (5-8 mm shackle)
- The switch insert can be equipped with an auxiliary contact, (see page 100)
C H
C1 E1
Ø 1x25 + 1xM32 (16-32 A)
B 2xM40 (63 A)
Dimensions (mm)
Type B C C1 E1 H
316MM... 135 165 91.5 125 198
416MM... 135 165 91.5 125 198
10/84 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Metal enclosed
32 A. IP44. Splashproof
Housing in aluminum. Cable entry 2 x M25 + 2 x M32. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
416MM6 3P+E
4 Grey AC 332MM1 2CMA167998R1000 1 1.42
Red 380/440 50/60 332MM3 2CMA167990R1000
Yellow 100...130 50 and 60 332MM4 2CMA167991R1000
Black 600...690 332MM5 2CMA167992R1000
Red 380...415 332MM6 2CMA167993R1000
Black 480...500 332MM7 2CMA167994R1000
Blue 200...250 332MM9 2CMA167995R1000
Green > 50 V~ 100...300 332MM10 2CMA167996R1000
Red 440...460 60 332MM11 2CMA167997R1000
10
3P+N+E
5 Grey AC 432MM1 2CMA168006R1000 1 1.48
Black 600...690 50 and 60 432MM5 2CMA126696R1000
Red 346...415 432MM6 2CMA168002R1000
Black 480...500 432MM7 2CMA168003R1000
Blue 208...250 432MM9 2CMA168004R1000
Red 440...460 60 432MM11 2CMA100027R1000
- The switch handle is padlockable (5-8 mm shackle)
- The switch insert can be equipped with an auxiliary contact, (see page 100)
C H
C1 E1
Ø 1x25 + 1xM32 (16-32 A)
B 2xM40 (63 A)
Dimensions (mm)
Type B C C1 E1 H
332MM... 135 165 91.5 135 198
432MM... 135 165 91.5 135 198
10/85
—
Switched interlocked socket outlets
Metal enclosed
63 A. IP44. Splashproof
Housing in aluminum. Cable entry 4 x M40.Cable area 6...25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
263MM6
3 Grey AC 263MM1 2CMA168033R1000 1 2.20
Yellow 100...130 50 and 60 263MM4 2CMA168030R1000
Blue 200...250 263MM6 2CMA168031R1000
Red 380...415 263MM9 2CMA168032R1000
3P+E
4 Grey AC 363MM1 2CMA168040R1000 1 2.22
Yellow 100...130 50 and 60 363MM4 2CMA168034R1000
Black 600...690 363MM5 2CMA168035R1000
Red 380...415 363MM6 2CMA168036R1000
10
Black 480...500 363MM7 2CMA168037R1000
Blue 200...250 363MM9 2CMA168038R1000
Red 440...460 60 363MM11 2CMA168039R1000
3P+N+E
5 Grey AC 463MM1 2CMA168046R1000 1 2.35
Black 600...690 50 and 60 463MM5 2CMA126697R1000
Red 346...415 463MM6 2CMA168042R1000
Black 480...500 463MM7 2CMA168043R1000
Blue 208...250 463MM9 2CMA168044R1000
C H
201
C1 E1
Ø 1x25 + 1xM32 (16-32 A)
B 2xM40 (63 A)
Dimensions (mm)
Type B C C1 E1 H
263MM... 165 201 91.5 183 228
363MM... 165 201 91.5 183 228
463MM... 165 201 91.5 183 228
10/86 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Metal enclosed
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
Blue 200...250 50 and 60 2125MM6 2CMA168047R1000 1 7.70
3P+E
4125MM6 4 Grey AC 3125MM1 2CMA168052R1000 1 7.90
Black 600...690 50 and 60 3125MM5 2CMA168061R1000
Red 380...415 3125MM6 2CMA168048R1000
Black 480...500 3125MM7 2CMA168049R1000
Blue 200...250 3125MM9 2CMA168050R1000
Red 440...460 60 3125MM11 2CMA168051R1000
3P+N+E
10
A E
B Ø7 F
C D
Dimensions (mm)
Type A B C D E F
2125MM... 230 210 370 405 230 31
3125MM... 230 210 370 405 230 31
4125MM... 230 210 370 405 230 31
10/87
—
Switched interlocked socket outlets
Horizontal
16 A. IP44. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm up/M25 down. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432MHS6 2P+E
3 Grey AC 216MHS1 2CMA167626R1000 1 0.55
Yellow 100...130 50 and 60 216MHS4 2CMA167622R1000
Blue 200...250 216MHS6 2CMA167623R1000
Red 380...415 216MHS9 2CMA167624R1000
Grey transf. 216MHS12 2CMA167625R1000
3P+E
4 Grey AC 316MHS1 2CMA167636R1000 1 0.58
Yellow 100...130 50 and 60 316MHS4 2CMA167629R1000
Black 600...690 316MHS5 2CMA167630R1000
10
Red 380...415 316MHS6 2CMA167631R1000
Black 480...500 316MHS7 2CMA167632R1000
Blue 200...250 316MHS9 2CMA167633R1000
Green > 50 V~ 100...300 316MHS10 2CMA167634R1000
Red 440...460 60 316MHS11 2CMA167635R1000
3P+N+E
5 Grey AC 416MHS1 2CMA167644R1000 1 0.61
Green > 50 V~ 100...300 416MHS2 2CMA167637R1000
Black 600...690 50 and 60 416MHS5 2CMA126684R1000
Red 346...415 416MHS6 2CMA167640R1000
Blue 200...250 416MHS9 2CMA167642R1000
32 A. IP44. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm up/M25 down. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232MHS1 2CMA167672R1000 1 0.60
Yellow 100...130 50 and 60 232MHS4 2CMA167668R1000
Blue 200...250 232MHS6 2CMA167669R1000
3P+E
4 Grey AC 332MHS1 2CMA167682R1000 1 0.63
Black 600...690 50 and 60 332MHS5 2CMA167676R1000
Red 380...415 332MHS6 2CMA167677R1000
Black 480...500 332MHS7 2CMA167678R1000
Blue 200...250 332MHS9 2CMA167679R1000
3P+N+E
5 Grey AC 432MHS1 2CMA167690R1000 1 0.66
Black 600...690 50 and 60 432MHS5 2CMA126685R1000
Red 346...415 432MHS6 *) 2CMA167686R1000
- The switch insert can be equipped with an auxiliary contact, (see page 100)
- Dimension drawing, (see page 90)
10/88 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Horizontal
63 A. IP44. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs Ø 32 mm. Cable area 6...25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
463MHS6
3 Grey AC 263MHS1 2CMA167717R1000 1 2.00
Yellow 100...130 50 and 60 263MHS4 2CMA167714R1000
Blue 200...250 263MHS6 2CMA167715R1000
3P+E
4 Grey AC 363MHS1 2CMA167725R1000 1 2.00
Black 600...690 50 and 60 363MHS5 2CMA167719R1000
Red 380...415 363MHS6 2CMA167721R1000
Black 480...500 363MHS7 2CMA167722R1000
Blue 200...250 363MHS9 2CMA167723R1000
10
3P+N+E
5 Grey AC 463MHS1 2CMA167731R1000 1 2.10
Black 600...690 50 and 60 463MHS5 2CMA126686R1000
Red 346...415 463MHS6 2CMA167727R1000
C1 E1
∅7
Dimensions (mm)
Type B C C1 E1 H
152
132
C1 E1
∅7
Dimensions (mm)
Type B C C1 E1 H
B ∅ 25 (16–32 A)
∅ 32 (63 A)
10/89
—
Switched interlocked socket outlets
Horizontal
16 A. IP67. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm up/M25 down. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
216MHS6W 2P+E
3 Grey AC 216MHS1W 2CMA167804R1000 1 0.55
Yellow 100...130 50 and 60 216MHS4W 2CMA167800R1000
Blue 200...250 216MHS6W 2CMA167801R1000
Black 480...500 216MHS7W 2CMA101715R1000
Red 380...415 216MHS9W 2CMA167802R1000
Grey transf. 216MHS12W 2CMA167803R1000
3P+E
4 Grey AC 316MHS1W 2CMA167814R1000 1 0.58
Green > 50 V~ >300...500 316MHS2W 2CMA167805R1000
10
Red 380/440 50/60 316MHS3W 2CMA167806R1000
Yellow 100...130 50 and 60 316MHS4W 2CMA167807R1000
Black 600...690 316MHS5W 2CMA167808R1000
Red 380...415 316MHS6W 2CMA167809R1000
Black 480...500 316MHS7W 2CMA167810R1000
Blue 200...250 316MHS9W 2CMA167811R1000
Green > 50 V~ 100...300 316MHS10W 2CMA167812R1000
Red 440...460 60 316MHS11W 2CMA167813R1000
3P+N+E
5 Grey AC 416MHS1W 2CMA167822R1000 1 0.61
Green > 50 V~ >300...500 416MHS2W 2CMA167815R1000
Red 380/440 50/60 416MHS3W 2CMA167816R1000
Yellow 100...130 50 and 60 416MHS4W 2CMA167817R1000
Red 346...415 416MHS6W 2CMA167818R1000
Black 480...500 416MHS7W 2CMA167819R1000
Blue 208...250 416MHS9W 2CMA167820R1000
Red 440...460 60 416MHS11W 2CMA167821R1000
- The switch insert can be equipped with an auxiliary contact, (see page 100)
C1 Ø7 E1
Dimensions (mm)
Type B C C1 E1 H
C H 216MHS...W 168 91 125 116 129
316MHS...W 168 91 125 116 129
416MHS...W 168 91 125 116 129
B Ø25
10/90 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Horizontal
32 A. IP67. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm up/M25 down. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432MHS6W
3 Grey AC 232MHS1W 2CMA167851R1000 1 0.60
Yellow 100...130 50 and 60 232MHS4W 2CMA167847R1000
Blue 200...250 232MHS6W 2CMA167848R1000
Red 380...415 232MHS9W 2CMA167849R1000
Grey transf. 232MHS12W 2CMA167850R1000
3P+E
4 Grey AC 332MHS1W 2CMA167861R1000 1 0.63
Green > 50 V~ >300...500 332MHS2W 2CMA167852R1000
Red 380/440 50/60 332MHS3W 2CMA167853R1000
10
3P+N+E
5 Grey AC 432MHS1W 2CMA167869R1000 1 0.66
Green > 50 V~ >300...500 432MHS2W 2CMA167862R1000
Red 380/440 50/60 432MHS3W 2CMA167863R1000
Yellow 100...130 50 and 60 432MHS4W 2CMA167864R1000
Red 346...415 432MHS6W 2CMA167865R1000
Black 480...500 432MHS7W 2CMA167866R1000
Blue 208...250 432MHS9W 2CMA167867R1000
Red 440...460 60 432MHS11W 2CMA167868R1000
- The switch insert can be equipped with an auxiliary contact, (see page 100)
C1 Ø7 E1
Dimensions (mm)
Type B C C1 E1 H
C H 232MHS...W 168 91 125 136 129
332MHS...W 168 91 125 136 129
432MHS...W 168 91 125 116 129
B Ø25
10/91
—
Switched interlocked socket outlets
Horizontal
63 A. IP67. Watertight
Housing in plastic (PBT). Cable entry with knock-outs knock-outs Ø 33 mm up/ Ø 33 down. Cable area 6...25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
263MHS6W 2P+E
3 Grey AC 263MHS1W 2CMA167896R1000 1 2.00
Yellow 100...130 50 and 60 263MHS4W 2CMA167893R1000
Blue 200...250 263MHS6W 2CMA167894R1000
Red 380...415 263MHS9W 2CMA167895R1000
3P+E
4 Grey AC 363MHS1W 2CMA167903R1000 1 2.00
Yellow 100...130 50 and 60 363MHS4W 2CMA167897R1000
Black 600...690 363MHS5W 2CMA167898R1000
Red 380...415 363MHS6W 2CMA167899R1000
10
Black 480...500 363MHS7W 2CMA167900R1000
Blue 200...250 363MHW9W 2CMA167901R1000
Red 440...460 60 363MHS11W 2CMA167901R1000
3P+N+E
5 Grey AC 463MHS1W 2CMA167909R1000 1 2.10
Yellow 100...130 50 and 60 463MHS4W 2CMA167904R1000
Red 346...415 463MHS6W 2CMA167905R1000
Black 480...500 463MHS7W 2CMA167906R1000
Blue 208...250 463MHS9W 2CMA167907R1000
Red 440...460 60 463MHS11W 2CMA167908R1000
C1 E1
∅7 Dimensions (mm)
□ □ 0 0 Type B C C1 E1 H
0 0 0 0 �
0 0
�
o-11: o-11:
0 0
263MHS...W 206 132 152 182 168
C H
363MHS...W 206 132 152 182 168
463MHS...W 206 132 152 182 168
j- j-
0 0 0 0
� �
B ∅ 25
□
0 0 �
0 0 o-11:
0
j-
0 0
�
10/92 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
With protection
63 A. IP67. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 33 mm up and down. Cable area 6...25 mm2.
Delivered with RCD.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 263MPR4W 2CMA101940R1000 1 1.90
Blue 200...250 263MPR6W 2CMA101941R1000
Red 380...415 263MPR9W 2CMA101942R1000
3P+E
363MPR6W
5 Yellow 100...130 50 and 60 363MPR4W 2CMA101937R1000 1 1.90
Red 346...415 363MPR6W 2CMA101938R1000
Blue 200...250 363MPR9W 2CMA101939R1000
3P+N+E
5 Yellow 100...130 50 and 60 463MPR4W 2CMA101935R1000 1 1.90
10
D1
D ø7
A C1
A1 C2
A C1
ø7
C
B ø 33
Dimensions (mm)
Type A A1 B C C1 C2 D D1 E
263MPR...W 168 337 206 152 132 300 108 138 175
363MPR...W 168 337 206 152 132 300 108 138 175
463MPR...W 168 337 206 152 132 300 108 138 175
10/93
—
Switched interlocked socket outlets
Vertical
16 A. IP44. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 216MVS1 2CMA167649R1000 1 0.63
Yellow 100...130 50 and 60 216MVS4 2CMA167645R1000
432MVS6
Blue 200...250 216MVS6 2CMA167646R1000
Red 380...415 216MVS9 2CMA167647R1000
Grey transf. 216MVS12 2CMA167648R1000
3P+E
4 Grey AC 316MVS1 2CMA167659R1000 1 0.67
Yellow 100...130 50 and 60 316MVS4 2CMA167652R1000
Black 600...690 316MVS5 2CMA167653R1000
10
Red 380...415 316MVS6 2CMA167654R1000
Black 480...500 316MVS7 2CMA167655R1000
Blue 200...250 316MVS9 2CMA167656R1000
Green > 50 V~ 100...300 316MVS10 2CMA167657R1000
Red 440...460 60 316MVS11 2CMA167658R1000
3P+N+E
5 Grey AC 416MVS1 2CMA167667R1000 1 0.70
Green > 50 V~ 300...500 416MVS2 2CMA167660R1000
Black 600...690 50 and 60 416MVS5 2CMA126690R1000
Red 346...415 416MVS6 2CMA167663R1000
Blue 200...250 416MVS9 2CMA167665R1000
32 A. IP44. Splashproof
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232MVS1 2CMA167695R1000 1 0.69
Yellow 100...130 50 and 60 232MVS4 2CMA167691R1000
Blue 200...250 232MVS6 2CMA167692R1000
3P+E
4 Grey AC 332MVS1 2CMA167705R1000 1 0.72
Black 600...690 50 and 60 332MVS5 2CMA167699R1000
Red 380...415 332MVS6 2CMA167700R1000
Black 480...500 332MVS7 2CMA167701R1000
Blue 200...250 332MVS9 2CMA167702R1000
3P+N+E
5 Grey AC 432MVS1 2CMA167713R1000 1 0.76
Black 600...690 50 and 60 432MVS5 2CMA126691R1000
Red 346...415 432MVS6 2CMA167709R1000
—
Switched interlocked socket outlets
Vertical
16 A. IP67. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 216MVS1W 2CMA167827R1000 1 0.63
3P+E
4 Grey AC 316MVS1W 2CMA167838R1000 1 0.67
Green > 50 V~ >300...500 316MVS2W 2CMA167828R1000
Red 380/440 50/60 316MVS3W 2CMA167829R1000
10
3P+N+E
5 Grey AC 416MVS1W 2CMA167846R1000 1 0.70
Green > 50 V~ >300...500 416MVS2W 2CMA167839R1000
Red 380/440 50/60 416MVS3W 2CMA167840R1000
Yellow 100...130 50 and 60 416MVS4W 2CMA167841R1000
Red 346...415 416MVS6W 2CMA167842R1000
Black 480...500 416MVS7W 2CMA167843R1000
Blue 208...250 416MVS9W 2CMA167844R1000
Red 440...460 60 416MVS11W 2CMA167845R1000
B
Ø 25x2
Ø 4.2
A C
D
C1
E
Dimensions (mm)
Type A B C C1 D E
216MVS...416MVS... 199.5 120 170 90 235 149
232MVS...432MVS... 199.5 120 170 90 235 149
216MVS...W 199.5 120 170 90 253 149
316MVS...W 199.5 120 170 90 253 149
416MVS...W 199.5 120 170 90 253 149
10/95
—
Switched interlocked socket outlets
Vertical
32 A. IP67. Watertight
Housing in plastic (PBT). Cable entry with knock-outs Ø 25 mm. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232MVS1W 2CMA167874R1000 1 0.69
Yellow 100...130 50 and 60 232MVS4W 2CMA167870R1000
432MVS6W
Blue 200...250 232MVS6W 2CMA167871R1000
Red 380...415 232MVS9W 2CMA167872R1000
Grey transf. 232MVS12W 2CMA167873R1000
3P+E
4 Grey AC 332MVS1W 2CMA167884R1000 1 0.72
Green > 50 V~ >300...500 332MVS2W 2CMA167875R1000
Red 380/440 50/60 332MVS3W 2CMA167876R1000
10
Yellow 100...130 50 and 60 332MVS4W 2CMA167877R1000
Black 600...690 332MVS5W 2CMA167878R1000
Red 380...415 332MVS6W 2CMA167879R1000
Black 480...500 332MVS7W 2CMA167880R1000
Blue 200...250 332MVS9W 2CMA167881R1000
Green > 50 V~ 100...300 332MVS10W 2CMA167882R1000
Red 440...460 60 332MVS11W 2CMA167883R1000
3P+N+E
5 Grey AC 432MVS1W 2CMA167892R1000 1 0.76
Green > 50 V~ >300...500 432MVS2W 2CMA167885R1000
Red 380/440 50/60 432MVS3W 2CMA167886R1000
Yellow 100...130 50 and 60 432MVS4W 2CMA167887R1000
Red 346...415 432MVS6W 2CMA167888R1000
Black 480...500 432MVS7W 2CMA167889R1000
Blue 208...250 432MVS9W 2CMA167890R1000
Red 440...460 60 432MVS11W 2CMA167891R1000
B
Ø 25x2 Ø 4.2
A C
D
C1
Dimensions (mm)
Type A B C C1 D E
232MVS...W 199.5 120 170 90 253 149
332MVS...W 199.5 120 170 90 253 149
432MVS...W 199.5 120 170 90 253 149
10/96 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Switched interlocked socket outlets
Vertical with protection
16 A. IP44. Splashproof
Housing in plastic (PBT). Contains RCD 25 A/0.03 A, type A.
Cable entry with knock-outs 2 x Ø 25 mm. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 216MPR6 2CMA167756R1000 1 1.71
3P+E
4 Red 380...415 50 and 60 316MPR6 2CMA167764R1000 1 1.74
Blue 200...250 316MPR9 2CMA167766R1000
3P+N+E
216MPR6
5 Red 346...415 50 and 60 416MPR6 2CMA167772R1000 1 1.76
10
32 A. IP44. Splashproof
Housing in plastic (PBT). Contains RCD 40 A/0.03 A, type A.
Cable entry with knock-outs 2 x Ø 25 mm. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232MPR6 2CMA167778R1000 1 1.77
3P+E
4 Red 380...415 50 and 60 332MPR6 2CMA167786R1000 1 1.78
Blue 200...250 332MPR9 2CMA167788R1000
3P+N+E
5 Red 346...415 50 and 60 432MPR6 2CMA167795R1000 1 1.80
B
Ø 25x2
Ø 4.2
A C
D
C1
E
Dimensions (mm)
Type A B C C1 D E
216MPR... 320 130 290 100 366 182
316MPR... 320 130 290 100 366 182
416MPR... 320 130 290 100 366 182
10/97
—
Surface socket outlets
Vertical with protection
16 A. IP44. Splashproof
Housing in plastic (PBT). Contains MCB type S200 characteristic C.
Cable entry with knock-outs 2 x Ø 25 mm. Cable area 1.5...4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 216RPM6 2CMA168133R1000 1 1.13
3P+E
216RPM6
4 Red 380...415 50 and 60 316RPM6 2CMA168141R1000 1 1.16
Blue 200...250 316RPM9 2CMA168143R1000
3P+N+E
5 Red 346...415 50 and 60 416RPM6 2CMA168150R1000 1 1.18
32 A. IP44. Splashproof
10
Housing in plastic (PBT). Contains MCB type S200 characteristic C.
Cable entry with knock-outs 2 x Ø 25 mm. Cable area 2.5...10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232RPM6 2CMA168156R1000 1 1.19
3P+E
4 Red 380...415 50 and 60 332RPM6 2CMA168164R1000 1 1.20
Blue 200...250 332RPM9 2CMA168166R1000
3P+N+E
5 Red 346...415 50 and 60 432RPM6 2CMA168173R1000 1 1.22
B
Ø 25x2 Ø 4.2
A C
D
C1
Dimensions (mm)
Type A B C C1 D E
216RPM...416RPM... 199.5 120 170 90 243 149
232RPM...432RPM... 199.5 120 170 90 243 149
10/98 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface socket outlets
Vertical with protection
16 A. IP44. Splashproof
Housing in plastic (PBT). Contains RCD 25 A / 0.03 A, type A
Cable entry with knock-outs 2 x Ø 25 mm. Cable area 1.5...4 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 216RPR6 2CMA168261R1000 1 1.13
216RPR6 3P+E
4 Red 380...415 50 and 60 316RPR6 2CMA168269R1000 1 1.16
Blue 200...250 316RPR9 2CMA168271R1000
3P+N+E
5 Red 346...415 50 and 60 416RPR6 2CMA168278R1000 1 1.18
32 A. IP44. Splashproof
10
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Blue 200...250 50 and 60 232RPR6 2CMA168283R1000 1 1.19
3P+E
4 Red 380...415 50 and 60 332RPR6 2CMA168291R1000 1 1.20
Blue 200...250 332RPR9 2CMA168293R1000
3P+N+E
5 Red 346...415 50 and 60 432RPR6 2CMA168300R1000 1 1.22
B
Ø 25x2 Ø 4.2
A C
D
C1
Dimensions (mm)
Type A B C C1 D E
216RPR...416RPR... 199.5 120 170 90 243 149
232RPR...432RPR... 199.5 120 170 90 243 149
10/99
—
Accessories
Auxillary contact
Pkg
Description Order Code qty
10
10/100 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Industrial plugs and sockets
Tough & Safe
— —
Plugs Connectors
— —
Inlets Socket outlet
10
For wall mounting, Type BS... For wall mounting, Type BS...W For wall mounting, Type RS... For wall mounting, Type RS...W
63 A, IP4 4 16 A...125 A, IP67 63 A, IP4 4 16 A...125 A, IP67
For panel mounting with For panel mounting with For panel mounting with unified For panel mounting with unified
straight flange, Type ...BU... straight flange, Type BU...W straight flange, Type RU... angled flange, Type RAU...
63 A, IP4 4 63 A...125 A, IP67 63 A, IP4 4 63 A, IP4 4
—
Product overview
Tough & Safe
Tough & Safe is the range for applications in envi- Features
ronments that have high demand of functionality • IP67 Watertight or IP44 Splashproof
and safety. The robust housing is made of PBT • 16-125 A, 50-690 VAC
plastic. The range Tough & Safe is available as wa- • IEC 60 309-1, -2
tertight (IP67, 16-125 A) and splashproof (IP44, 63 • All external screws are made of stainless steel
A). The devices are equipped with internal and ex-
ternal cable clamps. The 125 A devices are Application examples
equipped with two screws on each terminal. • Industry/workshops
• Harbours/shipyards
• Mines
• Food & beverage
10
of the terminals
Ground
Neutral N
Phase L1, L2, L3
External
screws made
of stainless steel
Type: 463P6W
Watertight chloroprene
onion skin grommet
Type:. 463C6W
10/102 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
63 A, IP44 Splashproof
Plastic enclosure (PBT). Cable entry with membrane. Cable area 4-16 mm2
Weight
Terminals/ Color Pkg pkg
463P6 Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 263P1 2CMA166746R1000 1 0.60
Yellow 100...130 50 and 60 263P4 2CMA166740R1000
Blue 200...250 263P6 2CMA166742R1000
Blue 200...250 263P9 2CMA166744R1000
3P+E
4 Grey AC 363P1 2CMA166760R1000 1 0.70
Black 600...690 50 and 60 363P5 2CMA166750R1000
Red 380...415 363P6 2CMA166752R1000
Black 480...500 363P7 2CMA166754R1000
10
3P+N+E
5 Red 346...415 50 and 60 463P6 2CMA166764R1000 1 0.75
Dimensions (mm)
Dmax B
Type A B C Dmax
—
Plugs
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry with compression gland. Cable area 1-2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216P6W
3 Grey AC 216P1W 2CMA166466R1000 1 0.18
Grey >50...250 DC 216P3W 2CMA166456R1000
Yellow 100...130 50 and 60 216P4W 2CMA166458R1000
Blue 200...250 216P6W 2CMA166460R1000
Red 380...415 216P9W 2CMA166462R1000
Grey transf 216P12W 2CMA166464R1000
3P+E
4 Grey AC 316P1W 2CMA166486R1000 1 0.24
Green > 50 V~ >300...500 316P2W 2CMA166468R1000
10
Red 380/440 50/60 316P3W 2CMA166470R1000
Yellow 100...130 50 and 60 316P4W 2CMA166472R1000
Black 600...690 316P5W 2CMA166474R1000
Red 380...415 316P6W 2CMA166476R1000
Black 480...500 316P7W 2CMA166478R1000
Blue 200...250 316P9W 2CMA166480R1000
Green > 50 V~ 100...300 316P10W 2CMA166482R1000
Red 440...460 60 316P11W 2CMA166484R1000
3P+N+E
5 Grey AC 416P1W 2CMA166502R1000 1 0.26
Green > 50 V~ >300...500 416P2W 2CMA166488R1000
Yellow 100...130 50 and 60 416P4W 2CMA166492R1000
Black 600...690 416P5W 2CMA126773R1000
Red 346...415 416P6W 2CMA166494R1000
Black 480...500 416P7W 2CMA166496R1000
Blue 208...250 416P9W 2CMA166498R1000
Red 440...460 60 416P11W 2CMA166500R1000
Dimensions (mm)
Dmax B
Type A B C Dmax
216P..W 128 71 94 13
C 316P..W 144 79 111 17
A 416P..W 146 87 112 17
10/104 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry with compression gland. Cable area 2.5-6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
432P6W 2P+E
3 Grey AC 232P1W 2CMA166728R1000 1 0.28
Grey > 50...250 DC 232P3W 2CMA105986R1000
Yellow 100...130 50 and 60 232P4W 2CMA166504R1000
Blue 200...250 232P6W 2CMA166722R1000
Red 380...415 232P9W 2CMA166724R1000
Grey transf 232P12W 2CMA166726R1000
3P+E
4 Grey AC 332P1W 2CMA166516R1000 1 0.30
Green > 50 V~ >300...500 332P2W 2CMA166730R1000
10
3P+N+E
5 Grey AC 432P1W 2CMA166532R1000 1 0.32
Green > 50 V~ >300...500 432P2W 2CMA166518R1000
Red 380/440 50/60 432P3W 2CMA166520R1000
Yellow 100...130 50 and 60 432P4W 2CMA166522R1000
Black 600...690 432P5W 2CMA126656R1000
Red 346...415 432P6W 2CMA166524R1000
Black 480...500 432P7W 2CMA166526R1000
Blue 208...250 432P9W 2CMA166528R1000
Red 440...460 60 432P11W 2CMA166530R1000
Dimensions (mm)
Dmax B
Type A B C Dmax
232P..W 147 94 105 21.5
C 332P..W 147 94 105 21.5
A 432P..W 161 101 119 21.5
10/105
—
Plugs
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry with compression gland, internal and external cable clamp. Cable area 4-16 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
263P6W
V Hz kg
2P+E
3 Grey AC 263P1W 2CMA166780R1000 1 0.95
Yellow 100...130 50 and 60 263P4W 2CMA166774R1000
Blue 200...250 263P6W 2CMA166776R1000
Red 380...415 263P9W 2CMA166778R1000
3P+E
4 Grey AC 363P1W 2CMA166794R1000 1 1.05
Yellow 100...130 50 and 60 363P4W 2CMA166782R1000
Black 600...690 363P5W 2CMA166784R1000
Red 380...415 363P6W 2CMA166786R1000
10
Black 480...500 363P7W 2CMA166788R1000
Blue 200...250 363P9W 2CMA166790R1000
Red 440...460 60 363P11W 2CMA166792R1000
3P+N+E
5 Grey AC 463P1W 2CMA166806R1000 1 1.15
Green > 50 V~ >300...500 463P2W 2CMA168186R1000
Yellow 100...130 50 and 60 463P4W 2CMA166796R1000
Red 346...415 463P6W 2CMA166798R1000
Black 480...500 463P7W 2CMA166800R1000
Blue 208...250 463P9W 2CMA166802R1000
Red 440...460 60 463P11W 2CMA166804R1000
Dimensions (mm)
Dmax B
Type A B C Dmax
—
Plugs
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
4125P6W
2P+E
3 Grey AC 2125P1W 2CMA166812R1000 1 1.32
Yellow 100...130 50 and 60 2125P4W 2CMA166808R1000
Blue 200...250 2125P6W 2CMA166810R1000
3P+E
4 Grey AC 3125P1W 2CMA166824R1000 1 1.43
Yellow 100...130 50 and 60 3125P4W 2CMA166814R1000
Black 600...690 3125P5W 2CMA166815R1000
Red 380...415 3125P6W 2CMA166816R1000
Black 480...500 3125P7W 2CMA166818R1000
10
3P+N+E
5 Grey AC 4125P1W 2CMA166836R1000 1 1.54
Yellow 100...130 50 and 60 4125P4W 2CMA166826R1000
Black 600...690 4125P5W 2CMA126658R1000
Red 346...415 4125P6W 2CMA166828R1000
Black 480...500 4125P7W 2CMA166830R1000
Blue 208...250 4125P9W 2CMA166832R1000
Black 440...460 60 4125P11W 2CMA166834R1000
C Type A B C Dmax
A 2125-4125P..W 313 130 242 48
10/107
—
Connectors
63 A, IP44 Splashproof
Plastic enclosure (PBT). Cable entry with membrane. Cable area 4-16 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
463C6
V Hz kg
2P+E
3 Grey AC 263C1 2CMA166844R1000 1 0.80
Yellow 100...130 50 and 60 263C4 2CMA166838R1000
Blue 200...250 263C6 2CMA166840R1000
Red 380...415 263C9 2CMA166842R1000
3P+E
4 Grey AC 363C1 2CMA166858R1000 1 0.83
Yellow 100...130 50 and 60 363C4 2CMA166846R1000
Black 600...690 363C5 2CMA166848R1000
Red 380...415 363C6 2CMA166850R1000
10
Black 480...500 363C7 2CMA166852R1000
Blue 200...250 363C9 2CMA166854R1000
Red 440...460 60 363C11 2CMA166856R1000
3P+N+E
5 Grey AC 463C1 2CMA166870R1000 1 0.88
Black 600...690 50 and 60 463C5 2CMA126661R1000
Red 346...415 463C6 2CMA166862R1000
Black 480...500 463C7 2CMA166864R1000
Blue 200...250 463C9 2CMA166866R1000
Dimensions (mm)
Dmax B
Type A B Dmax
263-463C.. 224 112 35
A
10/108 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Connectors
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry with compression gland. Cable area 1-2.5 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
216C6W V Hz kg
2P+E
3 Grey AC 216C1W 2CMA166544R1000 1 0.22
Yellow 100...130 50 and 60 216C4W 2CMA166536R1000
Blue 200...250 216C6W 2CMA166538R1000
Red 380...415 216C9W 2CMA166540R1000
Grey transf 216C12W 2CMA166542R1000
3P+E
4 Grey AC 316C1W 2CMA166564R1000 1 0.31
Green > 50 V~ >300...500 316C2W 2CMA166546R1000
Red 380/440 50/60 316C3W 2CMA166548R1000
10
3P+N+E
5 Grey AC 416C1W 2CMA166580R1000 1 0.32
Green > 50 V~ >300...500 416C2W 2CMA166566R1000
Red 380/440 50/60 416C3W 2CMA166568R1000
Yellow 100...130 50 and 60 416C4W 2CMA166570R1000
Black 600...690 416C5W 2CMA126662R1000
Red 346...415 416C6W 2CMA166572R1000
Black 480...500 416C7W 2CMA166574R1000
Blue 208...250 416C9W 2CMA166576R1000
Red 440...460 60 416C11W 2CMA166578R1000
Dimensions (mm)
Dmax B
Type A B Dmax
216C..W 151 80 13
A
316C..W 168 88 17
416C..W 170 97 17
10/109
—
Connectors
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry with compression gland. Cable area 2.5-6 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
432C6W V Hz kg
2P+E
3 Grey AC 232C1W 2CMA166590R1000 1 0.35
Yellow 100...130 50 and 60 232C4W 2CMA166582R1000
Blue 200...250 232C6W 2CMA166584R1000
Red 380...415 232C9W 2CMA166586R1000
Grey transf 232C12W 2CMA166588R1000
3P+E
4 Grey AC 332C1W 2CMA166592R1000 1 0.38
Green > 50 V~ >300...500 332C2W 2CMA166596R1000
Red 380/440 50/60 332C3W 2CMA166598R1000
10
Yellow 100...130 50 and 60 332C4W 2CMA166600R1000
Black 600...690 332C5W 2CMA166602R1000
Red 380...415 332C6W 2CMA166604R1000
Black 480...500 332C7W 2CMA166606R1000
Blue 200...250 332C9W 2CMA166608R1000
Green > 50 V~ 100...300 332C10W 2CMA166610R1000
Red 440...460 60 332C11W 2CMA166594R1000
3P+N+E
5 Grey AC 432C1W 2CMA166526R1000 1 0.41
Green > 50 V~ >300...500 432C2W 2CMA166612R1000
Red 380/440 50/60 432C3W 2CMA166614R1000
Yellow 100...130 50 and 60 432C4W 2CMA166616R1000
Black 600...690 432C5W 2CMA126663R1000
Red 346...415 432C6W 2CMA166618R1000
Black 480...500 432C7W 2CMA166620R1000
Blue 208...250 432C9W 2CMA166622R1000
Red 440...460 60 432C11W 2CMA166624R1000
Dimensions (mm)
Dmax B
Type A B Dmax
232C..W 177 102 21.5
A
332C..W 177 102 21.5
432C..W 182 109 21.5
10/110 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Connectors
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry with compression gland. Internal and external cable clamp. Cable area 4-16 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
263C6W
2P+E
3 Grey AC 263C1W 2CMA166878R1000 1 0.80
Yellow 100...130 50 and 60 263C4W 2CMA166872R1000
Blue 200...250 263C6W 2CMA166874R1000
Red 380...415 263C9W 2CMA166876R1000
3P+E
4 Grey AC 363C1W 2CMA166902R1000 1 0.83
Yellow 100...130 50 and 60 363C4W 2CMA166890R1000
Black 600...690 363C5W 2CMA166892R1000
Red 380...415 363C6W 2CMA166894R1000
10
3P+N+E
5 Grey AC 463C1W 2CMA166914R1000 1 0.88
Green > 50 V~ >300...500 463C2W 2CMA168184R1000
Yellow 100...130 50 and 60 463C4W 2CMA166904R1000
Red 346...415 463C6W 2CMA166906R1000
Black 480...500 463C7W 2CMA166908R1000
Blue 208...250 463C9W 2CMA166910R1000
Red 440...460 60 463C11W 2CMA166912R1000
Dimensions (mm)
Dmax B
Type A B Dmax
263-463C..W 286 111 41
A
10/111
—
Connectors
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
4125C6W
2P+E
3 Grey AC 2125C1W 2CMA166920R1000 1 1.37
Yellow 100...130 50 and 60 2125C4W 2CMA166916R1000
Blue 200...250 2125C6W 2CMA166918R1000
3P+E
4 Grey AC 3125C1W 2CMA166932R1000 1 1.41
Yellow 100...130 50 and 60 3125C4W 2CMA166922R1000
Black 600...690 3125C5W 2CMA166923R1000
Red 380...415 3125C6W 2CMA166924R1000
Red 380...415 3125C6W LP 2CMA169211R1000
10
Black 480...500 3125C7W 2CMA166926R1000
Blue 200...250 3125C9W 2CMA166928R1000
Red 440...460 60 3125C11W 2CMA166930R1000
3P+N+E
5 Grey AC 4125C1W 2CMA166944R1000 1 1.53
Yellow 100...130 50 and 60 4125C4W 2CMA166934R1000
Red 346...415 4125C6W 2CMA166936R1000
Red 346...415 4125C6W LP 2CMA169212R1000
Black 480...500 4125C7W 2CMA166938R1000
Blue 208...250 4125C9W 2CMA166940R1000
Red 440...460 60 4125C11W 2CMA166942R1000
Dimensions (mm)
Dmax B
Type A B Dmax
2125-4125C..W 325 122 48
A
10/112 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface socket outlets
Plastic enclosed
63 A, IP44 Splashproof
Plastic enclosure (PBT). Cable entry M32, alternative rear knock-out. Cable area 6-25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 263RS1 2CMA167480R1000 1 0.95
463RS6
Yellow 100...130 50 and 60 263RS4 2CMA167474R1000
Blue 200...250 263RS6 2CMA167476R1000
Red 380...415 263RS9 2CMA167478R1000
3P+E
4 Grey AC 363RS1 2CMA167506R1000 1 0.99
Yellow 100...130 50 and 60 363RS4 2CMA167494R1000
Black 600...690 363RS5 2CMA167496R1000
Red 380...415 363RS6 2CMA167498R1000
10
3P+N+E
5 Grey AC 463RS1 2CMA167492R1000 1 1.05
Black 600...690 50 and 60 463RS5 2CMA126668R1000
Red 346...415 463RS6 2CMA167484R1000
Black 480...500 463RS7 2CMA167486R1000
Blue 200...250 463RS9 2CMA167488R1000
E A
G
C1 Ø5.2 ØD
ØH
Dimensions (mm)
Type A B C C1 ØD E G H
263-463RS.. 136 254 170 95 M32 107 68 35
10/113
—
Surface socket outlets
Plastic enclosed
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry Ø 25 mm. Cable area 1.5-4 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 216RS4W 2CMA167148R1000 1 0.34
216RS6W
Blue 200...250 216RS6W 2CMA167149R1000
Red 380...415 216RS9W 2CMA167150R1000
Grey transf 216RS12W 2CMA167151R1000
Grey AC 216RS1W 2CMA167152R1000
3P+E
4 Green > 50 V~ >300...500 316RS2W 2CMA167153R1000 1 0.37
Red 380/440 50/60 316RS3W 2CMA167154R1000
Yellow 100...130 50 and 60 316RS4W 2CMA167155R1000
10
Black 600...690 316RS5W 2CMA167156R1000
Red 380...415 316RS6W 2CMA167157R1000
Black 480...500 316RS7W 2CMA167158R1000
Blue 200...250 316RS9W 2CMA167159R1000
Green > 50 V~ 100...300 316RS10W 2CMA167160R1000
Red 440...460 60 316RS11W 2CMA167161R1000
Grey AC 316RS1W 2CMA167162R1000
3P+N+E
5 Green > 50 V~ >300...500 416RS2W 2CMA167163R1000 1 0.40
Red 380/440 50/60 416RS3W 2CMA167164R1000
Yellow 100...130 50 and 60 416RS4W 2CMA167165R1000
Black 600...690 416RS5W 2CMA126669R1000
Red 346...415 416RS6W 2CMA167166R1000
Black 480...500 416RS7W 2CMA167167R1000
Blue 208...250 416RS9W 2CMA167168R1000
Red 440...460 60 416RS11W 2CMA167169R1000
Grey AC 416RS1W 2CMA167170R1000
E A
C1 ØF
ØD
C B
C2
Dimensions (mm)
Type A B C C1 D E G H
216RS..W 115 172 150 60 60 25 99 6.5
316RS..W 118 170 150 60 60 25 99 6.5
416RS..W 124 169 150 60 60 25 99 6.5
10/114 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface socket outlets
Plastic enclosed
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry Ø 25 mm. Cable area 2.5-10 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Yellow 100...130 50 and 60 232RS4W 2CMA167171R1000 1 0.41
232RS6W
Blue 200...250 232RS6W 2CMA167172R1000
Red 380...415 232RS9W 2CMA167173R1000
Grey transf 232RS12W 2CMA167174R1000
Grey AC 232RS1W 2CMA167175R1000
3P+E
4 Green > 50 V~ >300...500 332RS2W 2CMA167176R1000 1 0.43
Red 380/440 50/60 332RS3W 2CMA167177R1000
Yellow 100...130 50 and 60 332RS4W 2CMA167178R1000
10
3P+N+E
5 Green > 50 V~ >300...500 432RS2W 2CMA167186R1000 1 0.48
Red 380/440 50/60 432RS3W 2CMA167187R1000
Yellow 100...130 50 and 60 432RS4W 2CMA167188R1000
Black 600...690 432RS5W 2CMA126670R1000
Red 346...415 432RS6W 2CMA167189R1000
Black 480...500 432RS7W 2CMA167190R1000
Blue 208...250 432RS9W 2CMA167191R1000
Red 440...460 60 432RS11W 2CMA167192R1000
Grey AC 432RS1W 2CMA167193R1000
E A
C1 ØF
ØD
C B
C2
Dimensions (mm)
Type A B C C1 D E G H
232RS..W 129 178 150 60 6 25 99 6.5
332RS..W 129 178 150 60 60 25 99 6.5
432RS..W 131 178 150 60 60 25 99 6.5
10/115
—
Surface socket outlets
Plastic enclosed
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry Ø 32 mm. Cable area 6-25 mm2
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 263RS1W 2CMA167310R1000 1 1.00
Yellow 100...130 50 and 60 263RS4W 2CMA167304R1000
Blue 200...250 263RS6W 2CMA167306R1000
Red 380...415 263RS9W 2CMA167308R1000
263RS6W 3P+E
4 Grey AC 363RS1W 2CMA167324R1000 1 1.07
Yellow 100...130 50 and 60 363RS4W 2CMA167312R1000
Black 600...690 363RS5W 2CMA167314R1000
Red 380...415 363RS6W 2CMA167316R1000
10
Black 480...500 363RS7W 2CMA167318R1000
Blue 200...250 363RS9W 2CMA167320R1000
Red 440...460 60 363RS11W 2CMA167322R1000
3P+N+E
5 Grey AC 463RS1W 2CMA167336R1000 1 1.15
Yellow 100...130 50 and 60 463RS4W 2CMA167326R1000
Black 600...690 463RS5W 2CMA126671R1000
Red 346...415 463RS6W 2CMA167328R1000
Black 480...500 463RS7W 2CMA167330R1000
Blue 208...250 463RS9W 2CMA167332R1000
Red 440...460 60 463RS11W 2CMA167334R1000
E A
C1 ØF
ØD
C
B
C2
Dimensions (mm)
Type A B C C1 C2 D E F
263-463RS..W 150 263 176 76 76 32 118 8.0
10/116 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface socket outlets
Plastic enclosed
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 2125RS1W 2CMA167248R1000 1 1.45
Yellow 100...130 50 and 60 2125RS4W 2CMA167244R1000
Blue 200...250 2125RS6W 2CMA167246R1000
3P+E
4 Grey AC 3125RS1W 2CMA167260R1000 1 1.55
4125RS6W
Yellow 100...130 50 and 60 3125RS4W 2CMA167250R1000
Black 600...690 3125RS5W 2CMA167251R1000
Red 380...415 3125RS6W 2CMA167252R1000
Black 480...500 3125RS7W 2CMA167254R1000
10
3P+N+E
5 Grey AC 4125RS1W 2CMA167272R1000 1 1.69
Yellow 100...130 50 and 60 4125RS4W 2CMA167262R1000
Black 600...690 4125RS5W 2CMA126672R1000
Red 346...415 4125RS6W 2CMA167264R1000
Black 480...500 4125RS7W 2CMA167266R1000
Blue 208...250 4125RS9W 2CMA167268R1000
Red 440...460 60 4125RS11W 2CMA167270R1000
E A
C1 ØF
ØD
C
B
C2
Dimensions (mm)
Type A B C C1 C2 D E F
2125-4125RS..W 171 282 188 102 85 50 145 9.0
10/117
—
Surface socket outlets
For looping
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry knock-outs 2ר 25 mm. Terminal block 2×(2.5-10 mm2).
Outlet is connected to terminal block.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 216RL1W 2CMA168461R1000 1 0.63
Yellow 100...130 50 and 60 216RL4W 2CMA168457R1000
216RL6W Blue 200...250 216RL6W 2CMA168458R1000
Red 380...415 216RL9W 2CMA168459R1000
Grey transf DC 216RL12W 2CMA168460R1000
3P+E
4 Grey AC 316RL1W 2CMA168471R1000 1 0.66
Green > 50 V~ >300...500 316RL2W 2CMA168462R1000
Red 380/440 50/60 316RL3W 2CMA168463R1000
10
Yellow 100...130 50 and 60 316RL4W 2CMA168464R1000
Black 600...690 316RL5W 2CMA168465R1000
Red 380...415 316RL6W 2CMA168466R1000
Black 480...500 316RL7W 2CMA168467R1000
Blue 200...250 316RL9W 2CMA168468R1000
Green > 50 V~ 100...300 316RL10W 2CMA168469R1000
Red 440...460 60 316RL11W 2CMA168470R1000
3P+N+E
5 Grey AC 416RL1W 2CMA168479R1000 1 0.68
Green > 50 V~ >300...500 416RL2W 2CMA168472R1000
Red 380/440 50/60 416RL3W 2CMA168473R1000
Yellow 100...130 50 and 60 416RL4W 2CMA168474R1000
Red 346...415 416RL6W 2CMA168475R1000
Black 480...500 416RL7W 2CMA168476R1000
Blue 208...250 416RL9W 2CMA168477R1000
Red 440...460 60 416RL11W 2CMA168478R1000
120
90 Ø 4.2 Ø 25x2
170
253
149
10/118 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface socket outlets
For looping
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry knock-outs 2xØ 25 mm. Terminal block 2x(2.5-10 mm2).
Outlet is connected to terminal block.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232RL1W 2CMA168484R1000 1 0.69
Yellow 100...130 50 and 60 232RL4W 2CMA168480R1000
432RL6W
Blue 200...250 232RL6W 2CMA168481R1000
Red 380...415 232RL9W 2CMA168482R1000
Grey transf 232RL12W 2CMA168483R1000
3P+E
4 Grey AC 332RL1W 2CMA168494R1000 1 0.70
Green > 50 V~ >300...500 332RL2W 2CMA168485R1000
Red 380/440 50/60 332RL3W 2CMA168486R1000
10
3P+N+E
5 Grey AC 432RL1W 2CMA168502R1000 1 0.72
Green > 50 V~ >300...500 432RL2W 2CMA168495R1000
Red 380/440 50/60 432RL3W 2CMA168496R1000
Yellow 100...130 50 and 60 432RL4W 2CMA168497R1000
Red 346...415 432RL6W 2CMA168498R1000
Black 480...500 432RL7W 2CMA168499R1000
Blue 208...250 432RL9W 2CMA168500R1000
Red 440...460 60 432RL11W 2CMA168501R1000
120
90 Ø 4.2 Ø 25x2
170
253
149
10/119
—
Surface socket outlets
For looping
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 2125RL1W 2CMA168528R1000 1 4.00
Yellow 100...130 50 and 60 2125RL4W 2CMA168526R1000
Blue 200...250 2125RL6W 2CMA168527R1000
3P+E
4 Grey AC 3125RL1W 2CMA168534R1000 1 4.10
4125RL6W
Yellow 100...130 50 and 60 3125RL4W 2CMA168529R1000
Red 380...415 3125RL6W 2CMA168530R1000
Black 480...500 3125RL7W 2CMA168531R1000
Blue 200...250 3125RL9W 2CMA168532R1000
10
Red 440...460 60 3125RL11W 2CMA168533R1000
3P+N+E
5 Grey AC 4125RL1W 2CMA168540R1000 1 4.25
Yellow 100...130 50 and 60 4125RL4W 2CMA168535R1000
Red 346...415 4125RL6W 2CMA168536R1000
Black 480...500 4125RL7W 2CMA168537R1000
Blue 208...250 4125RL9W 2CMA168538R1000
Red 440...460 60 4125RL11W 2CMA168539R1000
- 2125 - 4125RL...W can be equipped with sealing up to 70 mm2.
- Cable clamps for Al available on request.
- RL...W have terminal block for 2 wire feeding under the same clamp.
230 210
204 Ø 6.5 Ø 2x50/25
236
510
204
2125 - 4125RL..W
10/120 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface inlets
63 A, IP44 Splashproof
Plastic enclosure (PBT). M32 alternative rear knock-out cable entry. Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 263BS1 2CMA167548R1000 1 0.80
Yellow 100...130 50 and 60 263BS4 2CMA167542R1000
Blue 200...250 263BS6 2CMA167544R1000
3P+E
4 Grey AC 363BS1 2CMA167562R1000 1 0.85
Yellow 100...130 50 and 60 363BS4 2CMA167550R1000
Black 600...690 363BS5 2CMA167552R1000
Red 380...415 363BS6 2CMA167554R1000
10
3P+N+E
5 Grey AC 463BS1 2CMA167574R1000 1 0.90
Black 600...690 50 and 60 463BS5 2CMA126701R1000
Red 346...415 463BS6 2CMA167566R1000
Black 480...500 463BS7 2CMA167568R1000
Blue 200...250 463BS9 2CMA167570R1000
107 117
Ø 5.2 68
95 M32
Ø 35
170
238
10/121
—
Surface inlets
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry Ø 25 mm. Cable area 1.5-4 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 216BS1W 2CMA167050R1000 1 0.36
Green > 50 V~ >300...500 216BS2W 2CMA167051R1000
Yellow 100...130 50 and 60 216BS4W 2CMA167042R1000
3P+E
4 Grey AC 316BS1W 2CMA167070R1000 1 0.41
Green > 50 V~ >300...500 316BS2W 2CMA167052R1000
10
Red 380/440 50/60 316BS3W 2CMA167054R1000
Yellow 100...130 50 and 60 316BS4W 2CMA167056R1000
Black 600...690 316BS5W 2CMA167058R1000
Red 380...415 316BS6W 2CMA167060R1000
Black 480...500 316BS7W 2CMA167062R1000
Blue 200...250 316BS9W 2CMA167064R1000
Green > 50 V~ 100...300 316BS10W 2CMA167066R1000
Red 440...460 60 316BS11W 2CMA167068R1000
3P+N+E
5 Grey AC 416BS1W 2CMA167086R1000 1 0.43
Green > 50 V~ >300...500 416BS2W 2CMA167072R1000
Red 380/440 50/60 416BS3W 2CMA167074R1000
Yellow 100...130 50 and 60 416BS4W 2CMA167076R1000
Black 600...690 416BS5W 2CMA126774R1000
Red 346...415 416BS6W 2CMA167078R1000
Black 480...500 416BS7W 2CMA167080R1000
Blue 208...250 416BS9W 2CMA167082R1000
Red 440...460 60 416BS11W 2CMA167084R1000
B
C1 ØF ØD
Dimensions (mm)
Type B C C1 D E1 F H
C H
216BS..W 99 150 60 28.3 129 06.6 196
316BS..W 99 150 60 28.3 132 06.5 202
416BS..W 99 150 60 28.3 134 06.5 209
E1
10/122 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface inlets
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry Ø 25 mm. Cable area 2.5-10 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 232BS1W 2CMA167096R1000 1 0.44
Yellow 100...130 50 and 60 232BS4W 2CMA167088R1000
Blue 200...250 232BS6W 2CMA167090R1000
Red 380...415 232BS9W 2CMA167092R1000
Grey transf 232BS12W 2CMA167094R1000
432BS6W
3P+E
4 Grey AC 332BS1W 2CMA167114R1000 1 0.46
Green > 50 V~ >300...500 332BS2W 2CMA167098R1000
Red 380/440 50/60 332BS3W 2CMA167100R1000
10
3P+N+E
5 Grey AC 432BS1W 2CMA167130R1000 1 0.48
Green > 50 V~ >300...500 432BS2W 2CMA167116R1000
Red 380/440 50/60 432BS3W 2CMA167118R1000
Yellow 100...130 50 and 60 432BS4W 2CMA167120R1000
Black 600...690 432BS5W 2CMA126776R1000
Red 346...415 432BS6W 2CMA167122R1000
Black 480...500 432BS7W 2CMA167124R1000
Blue 208...250 432BS9W 2CMA167126R1000
Red 440...460 60 432BS11W 2CMA167128R1000
B
C1 ØF ØD
Dimensions (mm)
C H
Type B C C1 D E1 F H
232BS..W 99 150 60 28.3 136 6.5 220
332BS..W 99 150 60 28.3 136 6.5 220
432BS..W 99 150 60 28.3 140 6.5 226
E1
10/123
—
Surface inlets
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable entry Ø 32 mm. Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 263BS1W 2CMA167344R1000 1 1.20
Yellow 100...130 50 and 60 263BS4W 2CMA167338R1000
Blue 200...250 263BS6W 2CMA167340R1000
263BS6W
Red 380...415 263BS9W 2CMA167342R1000
3P+E
4 Grey AC 363BS1W 2CMA167358R1000 1 1.30
Yellow 100...130 50 and 60 363BS4W 2CMA167346R1000
Black 600...690 363BS5W 2CMA167348R1000
Red 380...415 363BS6W 2CMA167350R1000
10
Black 480...500 363BS7W 2CMA167352R1000
Blue 200...250 363BS9W 2CMA167354R1000
Red 440...460 60 363BS11W 2CMA167356R1000
3P+N+E
5 Grey AC 463BS1W 2CMA167370R1000 1 1.40
Yellow 100...130 50 and 60 463BS4W 2CMA167360R1000
Black 600...690 463BS5W 2CMA126775R1000
Red 346...415 463BS6W 2CMA167362R1000
Black 480...500 463BS7W 2CMA167364R1000
Blue 208...250 463BS9W 2CMA167366R1000
Red 440...460 60 463BS11W 2CMA167368R1000
B
C1 ØF ØD
C
H
E1
Dimensions (mm)
Type B C C1 D E1 F H
263-463BS..W 118 176 76 38 138 8 249
10/124 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Surface inlets
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3 Grey AC 2125BS1W 2CMA167278R1000 1 4.00
Yellow 100...130 50 and 60 2125BS4W 2CMA167274R1000
Blue 200...250 2125BS6W 2CMA167276R1000
4125BS6W
3P+E
4 Grey AC 3125BS1W 2CMA167290R1000 1 4.10
Yellow 100...130 50 and 60 3125BS4W 2CMA167280R1000
Red 380...415 3125BS6W 2CMA167282R1000
Black 480...500 3125BS7W 2CMA167284R1000
Blue 200...250 3125BS9W 2CMA167286R1000
10
3P+N+E
5 Grey AC 4125BS1W 2CMA167302R1000 1 4.25
Yellow 100...130 50 and 60 4125BS4W 2CMA167292R1000
Black 600...690 4125BS5W 2CMA126705R1000
Red 346...415 4125BS6W 2CMA167294R1000
Black 480...500 4125BS7W 2CMA167296R1000
Blue 208...250 4125BS9W 2CMA167298R1000
Red 440...460 60 4125BS11W 2CMA167300R1000
B
C1 ØF ØD
C
H
E1
Dimensions (mm)
Type B C C1 D E1 F H
2125-4125BS..W 145 188 85 47 160 9 265
10/125
—
Panel mounted socket outlets
Unified straight flange
63 A, IP44 Splashproof
Plastic enclosure (PBT). Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
463RU6
2P+E
3 Grey AC 263RU1 2CMA167514R1000 1 0.60
Yellow 100...130 50 and 60 263RU4 2CMA167508R1000
Blue 200...250 263RU6 2CMA167510R1000
3P+E
4 Grey AC 363RU1 2CMA167528R1000 1 0.69
Black 600...690 50 and 60 363RU5 2CMA167518R1000
Red 380...415 363RU6 2CMA167520R1000
Black 480...500 363RU7 2CMA167522R1000
Blue 200...250 363RU9 2CMA167524R1000
10
3P+N+E
5 Grey AC 463RU1 2CMA167540R1000 1 0.76
Black 600...690 50 and 60 463RU5 2CMA126675R1000
Red 346...415 463RU6 2CMA167532R1000
Ø 4.2
C H
ØD
C1 E1 E
D2
Dimensions (mm)
Type C C1 D D2 E E1 H
263-463RU.. 61 61 70 104 87 48 112
10/126 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Panel mounted socket outlets
Unified straight flange
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
263RU6W V Hz kg
2P+E
3 Grey AC 263RU1W 2CMA167378R1000 1 0.64
Yellow 100...130 50 and 60 263RU4W 2CMA167372R1000
Blue 200...250 263RU6W 2CMA167374R1000
Red 380...415 263RU9W 2CMA167376R1000
3P+E
4 Grey AC 363RU1W 2CMA167392R1000 1 0.69
Yellow 100...130 50 and 60 363RU4W 2CMA167380R1000
Black 600...690 363RU5W 2CMA167382R1000
Red 380...415 363RU6W 2CMA167384R1000
10
3P+N+E
5 Grey AC 463RU1W 2CMA167404R1000 1 0.76
Green > 50 V~ >300...500 463RU2W 2CMA168182R1000
Yellow 100...130 50 and 60 463RU4W 2CMA167394R1000
Black 600...690 463RU5W 2CMA126676R1000
Red 346...415 463RU6W 2CMA167396R1000
Black 480...500 463RU7W 2CMA167398R1000
Blue 208...250 463RU9W 2CMA167400R1000
Red 440...460 60 463RU11W 2CMA167402R1000
Ø 4.2/6.5
C ØD H
C1 E1 E
D2
Dimensions (mm)
Type C C1 D D2 E E1 H
263RU..W...463RU...W 61 61 70 104 89 48 111
10/127
—
Panel mounted socket outlets
Unified straight flange
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
4125RU6W V Hz kg
2P+E
3 Grey AC 2125RU1W 2CMA167134R1000 1 0.85
Yellow 100...130 50 and 60 2125RU4W 2CMA167132R1000
Blue 200...250 2125RU6W 2CMA167133R1000
Blue 200...250 2125RU6W LP 2CMA192729R1000
3P+E
4 Grey AC 3125RU1W 2CMA167140R1000 1 1.00
Yellow 100...130 50 and 60 3125RU4W 2CMA167135R1000
Black 600...690 3125RU5W 2CMA126718R1000
Red 380...415 3125RU6W 2CMA167136R1000
10
Red 380...415 3125RU6W LP 2CMA192730R1000
Black 480...500 3125RU7W 2CMA167137R1000
Black 480...500 3125RU7W LP 2CMA101865R1000
Blue 200...250 3125RU9W 2CMA167138R1000
Blue 200...250 3125RU9W LP 2CMA101866R1000
Red 440...460 60 3125RU11W 2CMA167139R1000
Red 440...460 3125RU11W LP 2CMA101867R1000
3P+N+E
5 Grey AC 4125RU1W 2CMA167146R1000 1 1.14
Yellow 100...130 50 and 60 4125RU4W 2CMA167141R1000
Red 346...415 4125RU6W 2CMA167142R1000
Red 346...415 4125RU6W LP 2CMA169213R1000
Black 480...500 4125RU7W 2CMA167143R1000
Blue 208...250 4125RU9W 2CMA167144R1000
Red 440...460 60 4125RU11W 2CMA167145R1000
- Delivered with flange gasket.
Ø 4.2/6.5
C ØD H
C1 E1 E
D2
Dimensions (mm)
Type C C1 D D2 E E1 H
2125RU...W...4125RU..W 71 71 88 115 100 58 122
10/128 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Panel mounted socket outlets
Unified straight flange
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
3125RF6W LP
3 Blue 200...250 50 and 60 2125RF6W LP 2CMA101881R1000 1 1.2
3P+E
4 Grey AC 3125RF1W LP 2CMA101874R1000 1 1.23
Yellow 100...130 50 and 60 3125RF4W LP 2CMA101875R1000
Black 600...690 3125RF5W LP 2CMA101876R1000
Red 380...415 3125RF6W LP 2CMA101877R1000
Black 480...500 3125RF7W LP 2CMA101878R1000
Blue 200...250 3125RF9W LP 2CMA101879R1000
Red 440...460 60 3125RF11W LP 2CMA101880R1000
10
3P+N+E
5 Green > 50 V~ >300...500 4125RF2W LP 2CMA101871R1000 1 1.3
200/346... 50 and 60
Red 240/415 4125RF6W LP 2CMA101870R1000
120/208...
Blue 144/250 4125RF9W LP 2CMA101872R1000
250/440...
Red 265/460 60 4125RF11W LP 2CMA101873R1000
10/129
—
Panel mounted socket outlets
Unified angled flange
63 A, IP44 Splashproof
Plastic enclosure (PBT). Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
463RAU6
2P+E
3 Grey AC 263RAU1 2CMA167412R1000 1 0.60
Yellow 100...130 50 and 60 263RAU4 2CMA167406R1000
Blue 200...250 263RAU6 2CMA167408R1000
3P+E
4 Grey AC 363RAU1 2CMA167426R1000 1 0.63
Black 600...690 50 and 60 363RAU5 2CMA167416R1000
Red 380...415 363RAU6 2CMA167418R1000
Black 480...500 363RAU7 2CMA167420R1000
Blue 200...250 363RAU9 2CMA167422R1000
10
3P+N+E
5 Grey AC 463RAU1 2CMA167438R1000 1 0.69
Black 600...690 50 and 60 463RAU5 2CMA126680R1000
Red 346...415 463RAU6 2CMA167430R1000
Blue 200...250 463RAU9 2CMA101700R1000
D2
C1
ØD
D3 C
H
Ø 4.5
E1 E
Dimensions (mm)
Type C C1 D D2 D3 E E1 H
263-463RAU.. 84 80 92 100 104 62 73 111
10/130 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Panel mounted socket outlets
Unified angled flange
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 1.5-4 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216RAU6W
3 Grey AC 216RAU1W 2CMA167002R1000 1 0.12
Yellow 100...130 50 and 60 216RAU4W 2CMA166994R1000
Blue 200...250 216RAU6W 2CMA166996R1000
Red 380...415 216RAU9W 2CMA166998R1000
Grey transf 216RAU12W 2CMA167000R1000
3P+E
4 Grey AC 316RAU1W 2CMA167022R1000 1 0.15
Green > 50 V~ >300...500 316RAU2W 2CMA167004R1000
Red 380/440 50/60 316RAU3W 2CMA167006R1000
10
3P+N+E
5 Grey AC 416RAU1W 2CMA167038R1000 1 0.18
Green > 50 V~ >300...500 416RAU2W 2CMA167024R1000
Red 380/440 50/60 416RAU3W 2CMA167026R1000
Yellow 100...130 50 and 60 416RAU4W 2CMA167028R1000
Black 600...690 416RAU5W 2CMA126681R1000
Red 346...415 416RAU6W 2CMA167030R1000
Black 480...500 416RAU7W 2CMA167032R1000
Blue 208...250 416RAU9W 2CMA167034R1000
Red 440...460 60 416RAU11W 2CMA167036R1000
D2
C1
D2 C ØD H
Ø5 E1 E
Dimensions (mm)
Type C C1 D D2 E E1 H
216RAU..W 79.5 79.5 83 95 45 57 95
316RAU..W 79.5 79.5 83 95 45 57 95
416RAU..W 79.5 79.5 83 95 47 57 99
10/131
—
Panel mounted socket outlets
Unified angled flange
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 2.5-10 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432RAU6W 3 Grey AC 232RAU1W 2CMA166954R1000 1 0.19
Yellow 100...130 50 and 60 232RAU4W 2CMA166946R1000
Blue 200...250 232RAU6W 2CMA166948R1000
Red 380...415 232RAU9W 2CMA166950R1000
Grey transf 232RAU12W 2CMA166952R1000
3P+E
4 Grey AC 332RAU1W 2CMA166974R1000 1 0.21
Green > 50 V~ >300...500 332RAU2W 2CMA166956R1000
Red 380/440 50/60 332RAU3W 2CMA166958R1000
10
Yellow 100...130 50 and 60 332RAU4W 2CMA166960R1000
Black 600...690 332RAU5W 2CMA166962R1000
Red 380...415 332RAU6W 2CMA166964R1000
Black 480...500 332RAU7W 2CMA166966R1000
Blue 200...250 332RAU9W 2CMA166968R1000
Green > 50 V~ 100...300 332RAU10W 2CMA166970R1000
Red 440...460 60 332RAU11W 2CMA166972R1000
3P+N+E
5 Grey AC 432RAU1W 2CMA166990R1000 1 0.26
Green > 50 V~ >300...500 432RAU2W 2CMA166976R1000
Red 380/440 50/60 432RAU3W 2CMA166978R1000
Yellow 100...130 50 and 60 432RAU4W 2CMA166980R1000
Black 600...690 432RAU5W 2CMA126682R1000
Red 346...415 432RAU6W 2CMA166982R1000
Black 480...500 432RAU7W 2CMA166984R1000
Blue 208...250 432RAU9W 2CMA166986R1000
Red 440...460 60 432RAU11W 2CMA166988R1000
D2
C1
D2 C ØD H
Ø5 E1 E
Dimensions (mm)
Type C C1 D D2 E E1 H
232RAU..W 79.5 79.5 83 95 56 61 104
332RAU..W 79.5 79.5 83 95 56 61 104
432RAU..W 79.5 79.5 83 95 56 62 111
10/132 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Panel mounted socket outlets
Unified angled flange
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
463RAU6W 2P+E
3 Grey AC 263RAU1W 2CMA167446R1000 1 0.60
Yellow 100...130 50 and 60 263RAU4W 2CMA167440R1000
Blue 200...250 263RAU6W 2CMA167442R1000
Red 380...415 263RAU9W 2CMA167444R1000
3P+E
4 Grey AC 363RAU1W 2CMA167460R1000 1 0.63
Yellow 100...130 50 and 60 363RAU4W 2CMA167448R1000
Black 600...690 363RAU5W 2CMA167450R1000
Red 380...415 363RAU6W 2CMA167452R1000
10
3P+N+E
5 Grey AC 463RAU1W 2CMA167472R1000 1 0.69
Yellow 100...130 50 and 60 463RAU4W 2CMA167462R1000
Black 600...690 463RAU5W 2CMA126683R1000
Red 346...415 463RAU6W 2CMA167464R1000
Black 480...500 463RAU7W 2CMA167466R1000
Blue 208...250 463RAU9W 2CMA167468R1000
Red 440...460 60 463RAU11W 2CMA167470R1000
- Delivered with flange gasket.
D2
C1
D2 C ØD H
Ø4.2 E1 E
Dimensions (mm)
Type C C1 D D2 E E1 H
263-463RAU..W 84 80 92 104 61 71 115
10/133
—
Panel mounted socket inlets
Straight flange
63 A, IP44 Splashproof
Plastic enclosure (PBT). Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
463BU6
2P+E
3 Grey AC 263BU1 2CMA167216R1000 1 0.50
Blue 200...250 50 and 60 263BU6 2CMA167212R1000
3P+E
4 Grey AC 363BU1 2CMA167230R1000 1 0.55
Black 600...690 50 and 60 363BU5 2CMA167220R1000
Red 380...415 363BU6 2CMA167222R1000
Blue 200...250 363BU9 2CMA167226R1000
3P+N+E
5 Grey AC 463BU1 2CMA167242R1000 1 0.60
10
Red 346...415 50 and 60 463BU6 2CMA167234R1000
E
B
E1
H
H1
øD C
ø4.2
C E3
E4
B E2
E1
Dimensions (mm)
H
H1
Type B C D E E1 E3 E4 H H1
øD C
263-463BU.. 11 61 70 105 62.0 50.0 78.0 9 49.5
ø4.2
C E3
E4
10/134 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Panel mounted socket inlets
Straight flange
63 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 6-25 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
263BU6W 2P+E
3 Grey AC 263BU1W 2CMA168106R1000 1 0.50
Yellow 100...130 50 and 60 263BU4W 2CMA168103R1000
Blue 200...250 263BU6W 2CMA168104R1000
Red 380...415 263BU9W 2CMA168105R1000
3P+E
4 Grey AC 363BU1W 2CMA168113R1000 1 0.55
Yellow 100...130 50 and 60 363BU4W 2CMA168107R1000
Black 600...690 363BU5W 2CMA168108R1000
Red 380...415 363BU6W 2CMA168109R1000
10
3P+N+E
5 Grey AC 463BU1W 2CMA168119R1000 1 0.60
Green > 50 V~ >300...500 463BU2W 2CMA168180R1000
Yellow 100...130 50 and 60 463BU4W 2CMA168114R1000
Black 600...690 463BU5W 2CMA100859R1000
Red 346...415 463BU6W 2CMA168115R1000
Black 480...500 463BU7W 2CMA168116R1000
Blue 208...250 463BU9W 2CMA168117R1000
Red 440...460 60 463BU11W 2CMA168118R1000
- Delivered with flange gasket.
D2 E4
C ØD B
Ø4.2/6.5
C E3
Dimensions (mm)
Type B C D D2 E3 E4
263-463BU..W 112 61 70 98 50 80
10/135
—
Panel mounted socket inlets
Straight flange
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
4125BU6W
3 Grey AC 2125BU1W 2CMA167196R1000 1 0.78
Yellow 100...130 50 and 60 2125BU4W 2CMA167194R1000
Blue 200...250 2125BU6W 2CMA167195R1000
3P+E
4 Grey AC 3125BU1W 2CMA167202R1000 1 0.84
Yellow 100...130 50 and 60 3125BU4W 2CMA167197R1000
Black 600...690 3125BU5W 2CMA126719R1000
Red 380...415 3125BU6W 2CMA167198R1000
Black 480...500 3125BU7W 2CMA167199R1000
10
Blue 200...250 3125BU9W 2CMA167200R1000
Red 440...460 60 3125BU11W 2CMA167201R1000
3P+N+E
5 Grey AC 4125BU1W 2CMA167208R1000 1 0.96
Yellow 100...130 50 and 60 4125BU4W 2CMA167203R1000
Red 380...415 4125BU6W 2CMA167204R1000
Black 480...500 4125BU7W 2CMA167205R1000
Blue 208...250 4125BU9W 2CMA167206R1000
Red 440...460 60 4125BU11W 2CMA167207R1000
- Delivered with flange gasket.
D2 E4
C ØD B
Ø4.2/6.5
C E3
Dimensions (mm)
Type B C D D2 E3 E4
2125-4125BU..W 122 71 81 118 56 89
10/136 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Panel mounted socket inlets
Angled flange
16 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 1.5-4 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
216BAU6W
3 Grey AC 216BAU1W 2CMA166684R1000 1 0.14
Yellow 100...130 50 and 60 216BAU4W 2CMA166676R1000
Blue 200...250 216BAU6W 2CMA166678R1000
Red 380...415 216BAU9W 2CMA166680R1000
Grey transf 216BAU12W 2CMA166682R1000
3P+E
4 Grey AC 316BAU1W 2CMA166704R1000 1 0.19
Green > 50 V~ >300...500 316BAU2W 2CMA166686R1000
Red 380/440 50/60 316BAU3W 2CMA166688R1000
10
3P+N+E
5 Grey AC 416BAU1W 2CMA166720R1000 1 0.21
Green > 50 V~ >300...500 416BAU2W 2CMA166706R1000
Red 380/440 50/60 416BAU3W 2CMA166708R1000
Yellow 100...130 50 and 60 416BAU4W 2CMA166710R1000
Red 346...415 416BAU6W 2CMA166712R1000
Black 480...500 416BAU7W 2CMA166714R1000
Blue 208...250 416BAU9W 2CMA166716R1000
Red 440...460 60 416BAU11W 2CMA166718R1000
D2 C ØD
F
Ø5
C
D2 E3 E4
Dimensions (mm)
Type C D D2 E3 E4 F
216BAU..W 79.5 83 95 10 47 71
316BAU..W 79.5 83 95 10 53 79
416BAU..W 79.5 83 95 10 87 87
10/137
—
Panel mounted socket inlets
Angled flange
32 A, IP67 Watertight
Plastic enclosure (PBT). Cable area 2.5-10 mm2.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
2P+E
432BAU6W
3 Grey AC 232BAU1W 2CMA166636R1000 1 0.22
Yellow 100...130 50 and 60 232BAU4W 2CMA166628R1000
Blue 200...250 232BAU6W 2CMA166630R1000
Red 380...415 232BAU9W 2CMA166632R1000
Grey transf 232BAU12W 2CMA166634R1000
3P+E
4 Grey AC 332BAU1W 2CMA166656R1000 1 0.84
Green > 50 V~ >300...500 332BAU2W 2CMA166638R1000
Red 380/440 50/60 332BAU3W 2CMA166640R1000
10
Yellow 100...130 50 and 60 332BAU4W 2CMA166642R1000
Black 600...690 332BAU5W 2CMA166644R1000
Red 380...415 332BAU6W 2CMA166646R1000
Black 480...500 332BAU7W 2CMA166648R1000
Blue 200...250 332BAU9W 2CMA166650R1000
Green > 50 V~ 100...300 332BAU10W 2CMA166652R1000
Red 440...460 60 332BAU11W 2CMA166654R1000
3P+N+E
5 Grey AC 432BAU1W 2CMA166672R1000 1 0.96
Green > 50 V~ >300...500 432BAU2W 2CMA166658R1000
Red 380/440 50/60 432BAU3W 2CMA166660R1000
Yellow 100...130 50 and 60 432BAU4W 2CMA166662R1000
Red 346...415 432BAU6W 2CMA166664R1000
Black 480...500 432BAU7W 2CMA166666R1000
Blue 208...250 432BAU9W 2CMA166668R1000
Red 440...460 60 432BAU11W 2CMA166670R1000
- Delivered with flange gasket.
D2 C ØD
F
Ø5
C
D2 E3 E4
Dimensions (mm)
Type C D D2 E3 E4 F
232BAU..W 79.5 83 95 12 60 94
332BAU..W 79.5 83 95 12 60 94
432BAU..W 79.5 83 95 12 67 101
10/138 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Industrial plugs and sockets
Accessories
Plug blocker
Lockout/tagout for plugs and inlets. Can be used for any IEC 60309-1 and 60309-2 plug
or inlet, both IP44 and IP67 products.
qty
Padlock unit
Padlock unit suitable for all plugs and sockets with handle. Shackle for up to 6 padlocks.
—
Industrial plugs and sockets
Modular Combi
Modular Combi is a system consisting of compact units replacing outlets
that traditionally has been scattered around the walls.
Modular combi is a cost effective system.
Modular Combi is a cost effective system with metal. Common for them are among other fea-
different types of outlets, RCDs and MCBs in one tures that you only need one feeding cable, it can
location. Modular Combi is very easy to install be mounted with an already existing 4-wire as
and, thanks to the solutions and design, it saves well as 5-wire cable and that the modules are easy
time and money. to modify in the future for additional needs.
The Modular Combi range consists of two lines,
one product line in plastic, and the other one in
10
10/140 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Modular Combi
Plastic
The enclosure is in plastic. Modul Combi Plastic is designed for
different types of single phase domestic outlets and for IEC outlets up
to and including 63 A.
Covers: For MCB/RCD, maximum 13 modules, 2 opened and knock-outs for the rest of the
modules row. DIN-rail in bottom for terminals and MCB/RCDs.
With a distance at the bottom to allow wiring behind the rail. The lid is pad lockable.
10/141
—
Modular Combi
Plastic 16 A
IP44, Splashproof
Weight
MCB RCD Switch Schuko Outlet pkg
outlet Type Order Code Size (1pce)
10/16 A IEC W H D kg
1xS203 M C16 25 A/0.03 - 2 single 1x416 MPR16 2CMA168997R1000 250 300 160 3.1
3xS201 C16 40 A/0.03 - 3 single 3x416 MPR16/3 2CMA168995R1000 250 430 160 3.4
2xS203 M C16
1xS203 M C16 25 A/0.03 - 2 single 1x416 MPR16B * 2CMA101631R1000 250 300 160 3.1
1xS203 M C16 25 A/0.03 - 2 single 1x416 MPR16 BS 2CMA101651R1000 250 300 160 3.1
Grey **
1xS203 M C16 25 A/0.03 - 2 single 1x416 MPR16B BS 2CMA101655R1000 250 300 160 3.1
Black **
10
10/142 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Modular Combi
Plastic 16 A
Front view
MPR16/3
Wiring diagrams
—
Modular Combi
Plastic 32 A
IP44, Splashproof
Weight
MCB RCD Switch Schuko Outlet pkg
outlet Type Order Code Size (1pce)
10/16 A IEC W H D kg
3xS201 C16 63 A/0.03 - 3 single 1x416 MPR32/1 2CMA106211R1000 250 430 160 4.3
1xMCB 1x432
S203-C16
1xMCB
S203-C32
2xMCB 63 A/0.03 OT80F3/B 4 single 1x416 MPR32/1MS 2CMA168984R1000 250 560 160 4.8
S201-C16 1x432
1xMCB
S203-C16
1xMCB
S203-C32
MPR32/1MS
10
Front view
MPR32/1
MPR32/1MS
MPR32/1 MPR32/1MS
10/14 4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Modular Combi
Plastic
IP44, Splashproof
Housing in plastic (PBT)
Weight
MCB RCD Switch Schuko Outlet pkg
outlet Type Order Code Size (1pce)
10/16 A IEC W H D kg
Front view
Wiring diagrams
—
Modular Combi
Metal
The enclosure is in aluminium with front plates of galvanised steel.
Modul Combi Metal is designed for different types of single phase
domestic outlets and for IEC outlets up to and including 63 A.
10
With a distance at the bottom to allow wiring behind the rail. The lid is pad lockable.
10/146 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Modular Combi
Metal
IP44, Splashproof
Housing in Aluminium with front plates of galvanised steel
Weight
MCB RCD Switch Schuko Outlet pkg
outlet Type Order Code Size (1pce)
10/16 A IEC W H D kg
2xS201-C10 25 A/0.03 2 single 1x416 M16/2 JFB 2CMA179349R1000 250 314 172 4.55
1xS203-C16
2xS201-C10 25 A/0.03 2 single 1x416 M16/2 JFB 2CMA100020R1000 250 314 172 4.55
1xS203-C16 CTFL
4xS201-C10 63 A/0.03 4 single 1x416 M32/2 JFB 2CMA179351R1000 250 574 179 7.35
1xS203-C16 1x432
1xS203-C32
4xS201-C10 63 A/0.03 4 single 1x416 M32/2 JFB 2CMA100022R1000 250 574 179 7.35
1xS203-C16 1x432 CTFL
1xS203-C32
M63/2 JFB CTFL 3xS201-C10 63 A/0.03 4 single 1x416 M63/2 JFB 2CMA100024R1000 250 704 188 9.55
10
—
Modular Combi
Metal
Front view
M16/2JFB
M32/2JFB
M63/2JFB
10
Wiring diagrams
M16/2JFB
M32/2JFB M63/2JFB
10/148 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Modular Combi
Parts
We are offering modular combi parts for special requests that are not
covered by our standard range. The modular combi parts housing are
made of heavy duty PBT plastic material that guarantees robustness,
chemical resistance and high flammability rate in your application.
Modular Combi parts, IP44 There are a large number of socket outlets to
Plastic PBT choose from our Easy & Safe and Tough & Safe
Modular combi parts are Easy to assemble and in- Range depending on which IP degree and mate-
stall. It is a flexible and time efficient choice for rial that is required. There is also a possibility to
special applications. Modular combi parts can be have switched interlocked socket outlet to maxi-
assembled to a height of 2 meters and there is a mize personal safety. Assembled enclosure is
possibility to build on the width by looping if re- tested and fulfills IP44 protection degree and can
quired. Din rail are suitable for 13 modules with a handle Socket outlets up to 63A.
lot of space for your socket outlets protection.
10
10/149
—
Modular Combi parts
Top, bottom and middle section. Front and cover plates, cable
flange and N/E terminal
Weight
Pkg pkg
Description Type Order Code qty (1pce)
Top section FMCE40
kg
Middle section
Middle section incl. screws. Suitable for FMCE45 2CMA191082R1000 1 pce 0.25kg
Bottom section FMCE40 MP..., MPR...
10
Front plate with mechanical interlock, FMCE48 2CMA191085R1000 1 pce 0.5kg
switch OT16FT3, socket not included
Cover plate
Cover plate incl. screws FMCE42 2CMA191079R1000 1 pce 0.5kg
Cable flange
Hose clamp, cable tightening, flange FMCE41 2CMA170188R1000 1 pce 0.25kg
FMCE50 FMCE41 incl. screws
N/E terminal
FMCE50
N/E terminal 16 mm2, brass bar = 240 mm FMCE43 2CMA191080R1000 1 pce 0.19kg
DIN-Rail
FMCE54 FMCE53 DIN-Rail L=241 mm + screws + 5x35 mm 2 FMCE67 2CMA191103R1000 1 pce 0.3kg
terminal block
Flange
Flange for domestic socket, incl. screws FMCE70 2CMA105989R1000 1 pce 0.2kg
DIN-Rail
FMCE42 DIN-Rail L=241 mm, incl. screws FMCE71 2CMA105990R1000 1 pce 0.1kg
DIN-Rail
Lowered DIN-Rail, incl. screws FMCE72 2CMA105991R1000 1 pce 0.3kg
FMCE43
10/150 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Multi-pack Modular Combi
Top, bottom and middle section. Front and cover plates, cable
flange and N/E terminal
Pkg
Description Type Order Code qty
Top section FMCE400
Hose clamp
cable tightening, flange, FMCE410 2CMA106005R1000 10
Bottom section FMCE400 C-nuts, screws incl.
Cover plate
screws incl. FMCE420 2CMA106006R1000 10
N/E terminals 16 mm 2
Brass bars 2pcs length 240 mm, FMCE430 2CMA106007R1000 10
FMCE420
Clamps 16pcs, screws 8pcs
10
Middle section
screws incl. FMCE450 2CMA106008R1000 10
FMCE430
Front plate
suitable for two 63 A outlets FMCE460 2CMA106009R1000 10
screws incl.
Front plate
suitable for three 16-32 A outlets FMCE470 2CMA106010R1000 10
screws incl.
Flange
FMCE450 with Schuko outlet 10/16 A, FMCE500 2CMA106011R1000 10
screws incl.
Front
with lid (13 DIN modules wide), FMCE520 2CMA106012R1000 10
DIN-rail, screws incl.
Cover flange 63
FMCE460 screws incl. FMCE530 2CMA106013R1000 10
Lowered DIN-rail
screws incl. FMCE720 2CMA106015R1000 10
FMCE500
—
Black Modular Combi
Top, bottom and middle section. Front and cover plates, cable
flange and N/E terminal
Pkg
Description Type Order Code qty
Top section FMCE40B
Cover plate
screws incl. FMCE42B 2CMA105996R1000 Qty 1
Bottom section FMCE40B
Middle section
screws incl. FMCE45B 2CMA105997R1000 Qty 1
Front plate
suitable for three 16-32 A outlets FMCE47B 2CMA105998R1000 Qty 1
FMCE42B
screws incl.
10
Flange with Schuko outlet 10/16 A
screws incl. FMCE50B 2CMA105999R1000 Qty 1
FMCE47B
FMCE54B
10/152 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Industrial plugs and sockets
Extra low voltage
— —
Plugs Connectors
— —
Socket outlet Inlets
10
For panel mounting with straight For surface mounting, Type BSLV... For surface mounting, Type RSLV...
flange, Type RLV... 16 A...32A, IP4 4 16 A...32 A, IP4 4
16A...32 A, IP4 4
10/153
—
Industrial plugs and sockets
Extra low voltage
Our extra low voltage range offers Industrial plugs & sockets for
protection in areas with a high risk like swimming pools, wandering-
lead hand lamps, and other portable appliances for outdoor use.
Therefore our range includes products of IP44 and IP67.
°
°
120
120
S2
Secondary key
DC and fulfills IEC 60309. R1 T3
Main key
120° 120°
Extra low voltage is one way to protect from elec-
trical shock. Extra-low voltage is used where the
Positions and connections of the contact
risks are high: swimming pools, wandering-lead
10
hand lamps, and other portable appliances for
outdoor use, etc.
Table according to IEC 60309-2
The plugs and sockets are intended for an operat- Plugs and sockets for max. 50 V.
ing voltage not exceeding 50 V. Their rated volt-
age is 24 V and 50 V for 16 A and 32 A. Terminals/ Color Position of
Poles code Voltage Frequency secondary
V Hz key 1)
Standards
2 Violet 20-25 50-60 (none)
The products are designed according to the fol- White 40-50 50-60 12 h
lowing standards: IEC 60 309-1, 60 309-2. Green 20-25 100-200 4h
and 300 2h
40-50 400 3h
Connections >400-500 11 h
Screw type terminals. Grey DC 10 h
3 Violet 20-25 50-60 (none)
White 40-50 50-60 12 h
Non-interchangeability Green 20-25 100-200 4h
and 300 2h
To achieve non-interchangeability, the plugs and 40-50
400 3h
sockets have a main key and a secondary key. The >400-500 11 h
position of the secondary key is indicated by 1) The position of main key is defined as 6h (6 o´clock)
a number followed by a letter h (the hour position
or o´ clock position). The number is determined
by the position of the secondary key relative to
the main key, the position of which is defined as 6
o´clock. Non hour position is given for 20-25 V,
50-60 Hz, since there is no secondary key on
these plugs and sockets.
The width of the key is different for 16 A and 32
A plugs and sockets. In addition, there is a color
coding system: the cover or front part is violet on
20-25 V and white on 40-50 V plugs and sockets.
Plugs and sockets for direct current are grey.
10/154 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
For extra low voltage
16 A. IP44. Splashproof
Housing in plastic (PA). Cable entry with compression gland.
Weight
Terminals/ Color Pkg pkg
PLV216
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
32 A. IP44.Splashproof
Housing in plastic (PA). Cable entry with compression gland.
2 Violet 20...25 AC 50 and 60 PLV232 2CMA100883R1000 10 0.142
10
16 A. IP67. Watertight
Housing in plastic (PA). Cable entry with compression gland.
Weight
Terminals/ Color Pkg pkg
PLV216W Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
32 A. IP67. Watertight
Housing in plastic (PA). Cable entry with compression gland.
2 Violet 20...25 AC 50 and 60 PLV232W 2CMA100895R1000 10 0.164
Grey 25 and 50 DC - PLV232-10W 2CMA100897R1000
White 40...50 AC 50 and 60 PLV232-12W 2CMA100896R1000
—
Connectors
For extra low voltage
16 A. IP44. Splashproof
Housing in plastic (PA). Cable entry with compression gland.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
CLV216 V Hz kg
32 A. IP44.Splashproof
Housing in plastic (PA). Cable entry with compression gland.
2 Violet 20...25 AC 50 and 60 CLV232 2CMA100907R1000 10 0.178
10
Grey 25 and 50 DC - CLV232-10 2CMA100909R1000
White 40...50 AC 50 and 60 CLV232-12 2CMA100908R1000
16 A. IP67. Watertight
Housing in plastic (PA). Cable entry with compression gland.
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
CLV216W
32 A. IP67. Watertight
Housing in plastic (PA). Cable entry with compression gland.
2 Violet 20...25 AC 50 and 60 CLV232W 2CMA100919R1000 10 0.199
Grey 25 and 50 DC - CLV232-10W 2CMA100921R1000
White 40...50 AC 50 and 60 CLV232-12W 2CMA100920R1000
—
Socket outlets
For extra low voltage
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
RLV216 V Hz kg
RSLV216
2 Violet 20...25 AC 50 and 60 RSLV216 2CMA100985R1000 10 0.198
Grey 25 and 50 DC - RSLV216-10 2CMA100987R1000
White 40...50 AC 50 and 60 RSLV216-12 2CMA100986R1000
—
Inlets
For extra low voltage
Weight
Terminals/ Color Pkg pkg
Poles code Voltage Frequency Type Order Code qty (1pce)
V Hz kg
BSLV216
10
10/158 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Industrial plugs and sockets
High current connectors
The right soloution for every application.
The connector product portfolio covers almost all application in the
defined high current range.
—
C-Line - 200 A/250 A
The compact C-Line connectors have a robust
plastic housing and are perfect for applications
with limited space conditions as well as for cer-
tain industries (chemistry, food industry). Addi-
tional options allow use in a variety of applica-
tions.
10
—
B-Line - 250 A/400 A
The robust B-Line connectors are ideal for appli-
cations (tunneling, mining), where high mechani-
cal loads may arise. Furthermore, numerous op-
tions, such as the saltwater resistant housing,
make the connectors also suitable for marine ap-
plications.
—
Connector units 200 A...400 A
To ensure maximum safety for users, we can offer
special connector units:
CUMI (connector unit with mechanical interlock)
CUBC (connector unit with block contactor)
CUCB (connector unit with circuit breaker)
10/159
—
High current connectors
10
importance, the high current connectors are penetration)
always the right choice. • High security ensured at all times
The connectors of the C-Line and B-Line are IK 10 Special applications - on request
classified. • Vibration resistants screws
• Seawater resistant housing
Finger touch protection • Harnessed connectors
Each socket is equipped with a finger touch
protection in order to safeguard the user against Customized solutions
electrical shocks in the event of unintentional If standard solutions do not meet all the
contact with live parts. requiremens of an application, customer-specific
solutions are made upon request.
10/160 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
C-Line
The compact C-Line connectors have a robust plastic housing and are
perfect for applications with limited space conditions as well as for
certain industries (chemistry, food industry). Additional options allow
use in a variety of applications.
—
Plugs
C-Line
IP67. Watertight
Robust plastic housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
MC-S5/200 400V
3L+PEN
4 200 230 50/60 9 MC-S4/200A/230V 2CMA103139R1000 1 2.7
400 6 MC-S4/200A/400V 2CMA103140R1000
500 7 MC-S4/200A/500V 2CMA103141R1000
690 5 MC-S4/200A/690V 2CMA103142R1000
1000 1 MC-S4/200A/1000V 2CMA103143R1000
3L+N+PE
5 200 230 50/60 9 MC-S5/200A/230V 2CMA103144R1000 1 2.9
400 6 MC-S5/200A/400V 2CMA103145R1000
500 7 MC-S5/200A/500V 2CMA103146R1000
690 5 MC-S5/200A/690V 2CMA103147R1000
10
1000 1 MC-S5/200A/1000V 2CMA103148R1000
3L+PEN
4 250 230 50/60 9 MC-S4/250A/230V 2CMA103149R1000 1 2.7
400 6 MC-S4/250A/400V 2CMA103150R1000
500 7 MC-S4/250A/500V 2CMA103151R1000
690 5 MC-S4/250A/690V 2CMA103152R1000
1000 1 MC-S4/250A/1000V 2CMA103153R1000
3L+N+PE
5 250 230 50/60 9 MC-S5/250A/230V 2CMA103154R1000 1 2.9
1 2 400 3 4 6 MC-S5/250A/400V
5 6 2CMA103155R1000
7 8
500 7 MC-S5/250A/500V 2CMA103156R1000
A 690 5 MC-S5/250A/690V 2CMA103157R1000 A
B B
45-66
134
C C
142
302
ohne unser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
Diese Zeichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
367
—
Sockets
C-Line
IP67. Watertight
Robust plastic housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
FC-S5/200 400V 200
4 230 50/60 9 FC-S4/200 230V 2CMA103299R1000 1 3.4
400 6 FC-S4/200 400V 2CMA103300R1000
500 7 FC-S4/200 500V 2CMA103301R1000
690 5 FC-S4/200 690V 2CMA103302R1000
1000 1 FC-S4/200 1000V 2CMA103303R1000
3L+N+PE
5 200 230 50/60 9 FC-S5/200 230V 2CMA103304R1000 1 3.6
400 6 FC-S5/200 400V 2CMA103305R1000
500 7 FC-S5/200 500V 2CMA103306R1000
690 5 FC-S5/200 690V 2CMA103307R1000
10
3L+PEN
4 250 230 50/60 9 FC-S4/250 230V 2CMA103309R1000 1 3.4
400 6 FC-S4/250 400V 2CMA103310R1000
500 7 FC-S4/250 500V 2CMA103311R1000
690 5 FC-S4/250 690V 2CMA103312R1000
1000 1 FC-S4/250 1000V 2CMA103313R1000
3L+N+PE
5 250 230 50/60 9 FC-S5/250 230V 2CMA103314R1000 1 3.6
1 2 400 3 6 4 FC-S5/250 400V
5 2CMA103315R1000
6 7 8
B B
162
45-66
C C
ohne unser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
Diese Zeichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
329 178
394
E E
Gewicht 4-pol (3L+PEN) = 3.4kg
Gewicht 5-pol (3L+N+PE) = 3.6kg
—
Inlets for wall mounting
C-Line
IP67. Watertight
Robust plastic housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
MCW-S5/200 400V
4 200 230 50/60 9 MCW-S4/200 230V 2CMA103259R1000 1 3.6
400 6 MCW-S4/200 400V 2CMA103260R1000
500 7 MCW-S4/200 500V 2CMA103261R1000
690 5 MCW-S4/200 690V 2CMA103262R1000
1000 1 MCW-S4/200 1000V 2CMA103263R1000
3L+N+PE
5 200 230 50/60 9 MCW-S5/200 230V 2CMA103264R1000 1 3.8
400 6 MCW-S5/200 400V 2CMA103265R1000
500 7 MCW-S5/200 500V 2CMA103266R1000
690 5 MCW-S5/200 690V 2CMA103267R1000
10
1000 1 MCW-S5/200 1000V 2CMA103268R1000
3L+PEN
4 250 230 50/60 9 MCW-S4/250 230V 2CMA103269R1000 1 3.6
400 6 MCW-S4/250 400V 2CMA103270R1000
500 7 MCW-S4/250 500V 2CMA103271R1000
690 5 MCW-S4/250 690V 2CMA103272R1000
1000 1 MCW-S4/250 1000V 2CMA103273R1000
3L+N+PE
5 250 230 50/60 9 MCW-S5/250 230V 2CMA103274R1000 1 3.8
400 6 MCW-S5/250 400V 2CMA103275R1000
500 7 MCW-S5/250 500V 2CMA103276R1000
690 5 MCW-S5/250 690V 2CMA103277R1000
1000 1 MCW-S5/250 10000V 2CMA103278R1000
1 2 3 4 5 6 7 8
A 157 A
322 A
A 65
B B
240
C C
6
15°
45-6
ser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
eichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
150
ø9
175 100
E E
Gewicht 4-pol (3L+PEN) = 3.6kg
Gewicht 5-pol (3L+N+PE) = 3.8kg
—
Inlets for panel mounting
C-Line
IP67. Watertight
Robust housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 200 230 50/60 9 MCPA-S4/200 230V 2CMA103219R1000 1 4.2
400 6 MCPA-S4/200 400V 2CMA103220R1000
500 7 MCPA-S4/200 500V 2CMA103221R1000
MCPA-S5/200 400V
690 5 MCPA-S4/200 690V 2CMA103222R1000
1000 1 MCPA-S4/200 1000V 2CMA103223R1000
3L+N+PE
5 200 230 50/60 9 MCPA-S5/200 230V 2CMA103224R1000 1 4.4
400 6 MCPA-S5/200 400V 2CMA103225R1000
500 7 MCPA-S5/200 500V 2CMA103226R1000
690 5 MCPA-S5/200 690V 2CMA103227R1000
10
3L+PEN
4 250 230 50/60 9 MCPA-S4/250 230V 2CMA103229R1000 1 4.2
400 6 MCPA-S4/250 400V 2CMA103230R1000
500 7 MCPA-S4/250 500V 2CMA103231R1000
690 5 MCPA-S4/250 690V 2CMA103232R1000
1000 1 MCPA-S4/250 1000V 2CMA103233R1000
3L+N+PE
5 250 230 50/60 9 MCPA-S5/250 230V 2CMA103234R1000 1 4.4
400 6 MCPA-S5/250 400V 2CMA103235R1000
500 7 MCPA-S5/250 500V 2CMA103236R1000
690 5 MCPA-S5/250 690V 2CMA103237R1000
1000 1 MCPA-S5/250 1000V 2CMA103238R1000
1 2 3 4 5 6 7 8
140
158
A 120 A
9
B B
120
140
276
C C
r Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
hnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
15°
141
E E
Gewicht 4-pol (3L+PEN) = 4.2kg
Gewicht 5-pol (3L+N+PE) = 4.4kg
—
Inlets for panel mounting
C-Line
IP67. Watertight
Robust housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+N+PE
5 200 230 50/60 9 MCP-S5/200 230V 2CMA103184R1000 1 2.4
400 6 MCP-S5/200 400V 2CMA103185R1000
500 7 MCP-S5/200 500V 2CMA103186R1000
690 5 MCP-S5/200 690V 2CMA103187R1000
10
1000 1 MCP-S5/200 1000V 2CMA103188R1000
3L+PEN
4 250 230 50/60 9 MCP-S4/250 230V 2CMA103189R1000 1 2.2
400 6 MCP-S4/250 400V 2CMA103190R1000
500 7 MCP-S4/250 500V 2CMA103191R1000
690 5 MCP-S4/250 690V 2CMA103192R1000
1000 1 MCP-S4/250 1000V 2CMA103193R1000
3L+N+PE
5 250 230 50/60 9 MCP-S5/250 230V 2CMA103194R1000 1 2.4
400 6 MCP-S5/250 400V 2CMA103195R1000
500 7 MCP-S5/250 500V 2CMA103196R1000
690 5 MCP-S5/250 690V 2CMA103197R1000
1000 1 MCP-S5/250 1000V 2CMA103198R1000
1 2 3 4 5 6 7
A 155 140
120
119
B
120
140
9
ich gemacht werden.
ecklin AG. Sie darf
D
10/166 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet for wall mounting
C-Line
IP67. Watertight
Robust plastic housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 200 230 50/60 9 FCW-S4/200 230V 2CMA103419R1000 1 4.3
FCW-S5/200 400V 400 6 FCW-S4/200 400V 2CMA103420R1000
500 7 FCW-S4/200 500V 2CMA103421R1000
690 5 FCW-S4/200 690V 2CMA103422R1000
1000 1 FCW-S4/200 1000V 2CMA103423R1000
3L+N+PE
5 200 230 50/60 9 FCW-S5/200 230V 2CMA103424R1000 1 4.5
400 6 FCW-S5/200 400V 2CMA103425R1000
500 7 FCW-S5/200 500V 2CMA103426R1000
690 5 FCW-S5/200 690V 2CMA103427R1000
10
3L+PEN
4 250 230 50/60 9 FCW-S4/250 230V 2CMA103429R1000 1 4.3
400 6 FCW-S4/250 400V 2CMA103430R1000
500 7 FCW-S4/250 500V 2CMA103431R1000
690 5 FCW-S4/250 690V 2CMA103432R1000
1000 1 FCW-S4/250 1000V 2CMA103433R1000
3L+N+PE
5 250 230 50/60 9 FCW-S5/250 230V 2CMA103434R1000 1 4.5
400 6 FCW-S5/250 400V 2CMA103435R1000
500 7 FCW-S5/250 500V 2CMA103436R1000
690 5 FCW-S5/250 690V 2CMA103437R1000
1000 1 FCW-S5/250 1000V 2CMA103438R1000
1 2 3 4 5 6 7 8
A A
349 178
A
A
B B
65
256
C C
6
45-6
15°
ne unser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
ese Zeichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
150
100 ø9
175
146
E E
Gewicht 4-pol (3L+PEN) = 4.3kg
Gewicht 5-pol (3L+N+PE) = 4.5kg
—
Socket outlet for wall mounting
C-Line
IP67. Watertight
Robust housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 200 230 50/60 9 FCPA-S4/200 230V 2CMA103379R1000 1 4.4
400 6 FCPA-S4/200 400V 2CMA103380R1000
500 7 FCPA-S4/200 500V 2CMA103381R1000
FCPA-S5/200 400V
690 5 FCPA-S4/200 690V 2CMA103382R1000
1000 1 FCPA-S4/200 1000V 2CMA103383R1000
3L+N+PE
5 200 230 50/60 9 FCPA-S5/200 230V 2CMA103384R1000 1 4.6
400 6 FCPA-S5/200 400V 2CMA103385R1000
500 7 FCPA-S5/200 500V 2CMA103386R1000
690 5 FCPA-S5/200 690V 2CMA103387R1000
10
1000 1 FCPA-S5/200 1000V 2CMA103388R1000
3L+PEN
4 250 230 50/60 9 FCPA-S4/250 230V 2CMA103389R1000 1 4.4
400 6 FCPA-S4/250 400V 2CMA103390R1000
500 7 FCPA-S4/250 500V 2CMA103391R1000
690 5 FCPA-S4/250 690V 2CMA103392R1000
1000 1 FCPA-S4/250 1000V 2CMA103393R1000
3L+N+PE
5 250 230 50/60 9 FCPA-S5/250 230V 2CMA103394R1000 1 4.6
400 6 FCPA-S5/250 400V 2CMA103395R1000
500 7 FCPA-S5/250 500V 2CMA103396R1000
690 5 FCPA-S5/250 690V 2CMA103397R1000
1000 1 FCPA-S5/250 1000V 2CMA103398R1000
1 2 3 4 5 6 7 8
A 180 140 A
120
9
B B
120
140
C C
nser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
eichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
E 15° E
178
—
Socket outlet for panel mounting
C-Line
IP67. Watertight
Robust housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
FCP-S5/200 400V 200
4 230 50/60 9 FCP-S4/200 230V 2CMA103339R1000 1 3.2
400 6 FCP-S4/200 400V 2CMA103340R1000
500 7 FCP-S4/200 500V 2CMA103341R1000
690 5 FCP-S4/200 690V 2CMA103342R1000
1000 1 FCP-S4/200 1000V 2CMA103343R1000
3L+N+PE
5 200 230 50/60 9 FCP-S5/200 230V 2CMA103344R1000 1 3.5
400 6 FCP-S5/200 400V 2CMA103345R1000
500 7 FCP-S5/200 500V 2CMA103346R1000
690 5 FCP-S5/200 690V 2CMA103347R1000
10
3L+PEN
4 250 230 50/60 9 FCP-S4/250 230V 2CMA103349R1000 1 3.2
400 6 FCP-S4/250 400V 2CMA103350R1000
500 7 FCP-S4/250 500V 2CMA103351R1000
690 5 FCP-S4/250 690V 2CMA103352R1000
1000 1 FCP-S4/250 1000V 2CMA103353R1000
3L+N+PE
5 250 230 50/60 9 FCP-S5/250 230V 2CMA103354R1000 1 3.5
400 6 FCP-S5/250 400V 2CMA103355R1000
500 7 FCP-S5/250 500V 2CMA103356R1000
1 2 3 4 5 6 7
690 5 FCP-S5/250 690V 2CMA103357R1000
1000 1 FCP-S5/250 1000V 2CMA103358R1000
A
120
36
B
9
120
120
140
20
140
kopiert noch Dritten zugänglich gemacht werden.
igentum der Rauscher & Stoecklin AG. Sie darf
D
145 178
—
B-Line
10
Protection grade IP67
Shock resistance IK10
Ambient temperature °C -40/+100
Insulation resistance (Phase-phase and phase-earth) MOhm >500
Comparative tracking index of the insert CTI >600
Terminal cross-section (EN 60228 Class 5) mm2 70-240
Max cross section pilot cable, conductor (EN 60228 mm2 4
Class 5)
Diameter of cable - separat pilot cable mm 34-66
Diameter of cable mm 8-15
10/170 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Plugs
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+N+PE
5 250 230 50/60 9 MC-S5/250A/230V 2CMA103164R1000 1 8.6
400 6 MC-S5/250A/400V 2CMA103165R1000
500 7 MC-S5/250A/500V 2CMA103166R1000
690 5 MC-S5/250A/690V 2CMA103167R1000
10
3L+PEN
4 400 230 50/60 9 MC-S4/400A/230V 2CMA103169R1000 1 8.1
400 6 MC-S4/400A/400V 2CMA103170R1000
500 7 MC-S4/400A/500V 2CMA103171R1000
690 5 MC-S4/400A/690V 2CMA103172R1000
1000 1 MC-S4/400A/1000V 2CMA103173R1000
3L+N+PE
5 400 230 50/60 9 MC-S5/400A/230V 2CMA103174R1000 1 8.6
400 6 MC-S5/400A/400V 2CMA103175R1000
This drawing remains mental properties of Rauscher & Stoecklin AG. It may
neither be 7
1 2 3500 4 MC-S5/400A/500V
copied nor third
5 2CMA103176R1000
be made accessible without our agreement.
6
690 5 MC-S5/400A/690V 2CMA103177R1000
C
F
467 568
402 264
5 6 7 8
2
A
179
3
B
179
45-66
-66
10/171
—
Sockets
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+N+PE
5 250 230 50/60 9 FC-S5/250 230V 2CMA103324R1000 1 9.9
400 6 FC-S5/250 400V 2CMA103325R1000
500 7 FC-S5/250 500V 2CMA103326R1000
690 5 FC-S5/250 690V 2CMA103327R1000
10
1000 1 FC-S5/250 1000V 2CMA103328R1000
3L+PEN
4 400 230 50/60 9 FC-S4/400 230V 2CMA103329R1000 1 9.4
400 6 FC-S4/400 400V 2CMA103330R1000
1 2 3 4 5 6
500 7 FC-S4/400 500V 2CMA103331R1000
690 5 FC-S4/400 690V 2CMA103332R1000
1000 1 FC-S4/400 1000V 2CMA103333R1000
A
3L+N+PE
5 400 230 50/60 9 FC-S5/400 230V 2CMA103334R1000 1 9.9
400 6 FC-S5/400 400V 2CMA103335R1000
500 7 FC-S5/400 500V 2CMA103336R1000
690 5 FC-S5/400 690V 2CMA103337R1000
1000 1 FC-S5/400 1000V 2CMA103338R1000
B
45-66
238
C
er kopiert noch Dritten zugänglich gemacht werden.
447 65 213
s Eigentum der Rauscher & Stoecklin AG. Sie darf
E
10/172 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets for wall mounting
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
MCW-S5/250 400V
4 250 230 50/60 9 MCW-S4/250 230V 2CMA103279R1000 1 10.0
400 6 MCW-S4/250 400V 2CMA103280R1000
500 7 MCW-S4/250 500V 2CMA103281R1000
690 5 MCW-S4/250 690V 2CMA103282R1000
1000 1 MCW-S4/250 1000V 2CMA103283R1000
3L+N+PE
5 250 230 50/60 9 MCW-S5/250 230V 2CMA103284R1000 1 10.5
400 6 MCW-S5/250 400V 2CMA103285R1000
500 7 MCW-S5/250 500V 2CMA103286R1000
690 5 MCW-S5/250 690V 2CMA103287R1000
10
3L+PEN
4 400 230 50/60 9 MCW-S4/400 230V 2CMA103289R1000 1 10.0
400 1 6 2
MCW-S4/400 400V 3
2CMA103290R1000 4
500 7 MCW-S4/400 500V 2CMA103291R1000
690 5 MCW-S4/400 690V 2CMA103292R1000
A
1000 1 MCW-S4/400 1000V 2CMA103293R1000
3L+N+PE
5 400 230 50/60 9 MCW-S5/400 230V 2CMA103294R1000 1 10.5
1 2 3 400 4 6 MCW-S5/400 5
400V 2CMA103295R1000
6 7
402
1 2 500 3 7 4
MCW-S5/400 500V 5
2CMA103296R1000 6
65
690 5 MCW-S5/400 690V 2CMA103297R1000
A 1000
B 1 A
MCW-S5/400 1000V 2CMA103298R1000
A
241
264
402 264
10°
402 65
B A 65
A C
45-66
B 11 140
45-66
241
241
10°
10°
eder kopiert noch Dritten zugänglich gemacht werden.
ges Eigentum der Rauscher & Stoecklin AG. Sie darf
C
11 D 140
C
11 140
D
h gemacht werden.
E
cklin AG. Sie darf
140 ø9
D
174
A
10/173
—
Inlets for panel mounting
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 250 230 50/60 9 MCPA-S4/250 230V 2CMA103239R1000 1 9.8
400 6 MCPA-S4/250 400V 2CMA103240R1000
500 7 MCPA-S4/250 500V 2CMA103241R1000
3L+N+PE
5 250 230 50/60 9 MCPA-S5/250 230V 2CMA103244R1000 1 10.3
400 6 MCPA-S5/250 400V 2CMA103245R1000
500 7 MCPA-S5/250 500V 2CMA103246R1000
690 5 MCPA-S5/250 690V 2CMA103247R1000
10
1000 1 MCPA-S5/250 1000V 2CMA103248R1000
3L+PEN
4 400 230 50/60 9 MCPA-S4/400 230V 2CMA103249R1000 1 9.8
400 6 MCPA-S4/400 400V 2CMA103250R1000
500 7 MCPA-S4/400 500V 2CMA103251R1000
690 5 MCPA-S4/400 690V 2CMA103252R1000
1000 1 MCPA-S4/400 1000V 2CMA103253R1000
3L+N+PE
5 400 230 50/60 9 MCPA-S5/400 230V 2CMA103254R1000 1 10.3
1 2 3 4 5 6 7
400 6 MCPA-S5/400 400V 2CMA103255R1000
500 7 MCPA-S5/400 500V 2CMA103256R1000
690 5 MCPA-S5/400 690V 2CMA103257R1000
A
1000 1 MCPA-S5/400 1000V 2CMA103258R1000
180 220
155
B
11
180
155
C
400
ugänglich gemacht werden.
r & Stoecklin AG. Sie darf
D
15°
264
10/174 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Inlets for panel mounting
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
MCP-S5/250 400V
4 250 230 50/60 9 MCP-S4/250 230V 2CMA103199R1000 1 8.1
400 6 MCP-S4/250 400V 2CMA103200R1000
500 7 MCP-S4/250 500V 2CMA103201R1000
690 5 MCP-S4/250 690V 2CMA103202R1000
1000 1 MCP-S4/250 1000V 2CMA103203R1000
3L+N+PE
5 250 230 50/60 9 MCP-S5/250 230V 2CMA103204R1000 1 8.6
400 6 MCP-S5/250 400V 2CMA103205R1000
500 7 MCP-S5/250 500V 2CMA103206R1000
690 5 MCP-S5/250 690V 2CMA103207R1000
10
3L+PEN
4 400 230 50/60 9 MCP-S4/400 230V 2CMA103209R1000 1 8.1
400 6 MCP-S4/400 400V 2CMA103210R1000
500 7 MCP-S4/400 500V 2CMA103211R1000
690 5 MCP-S4/400 690V 2CMA103212R1000
1000 1 MCP-S4/400 1000V 2CMA103213R1000
3L+N+PE
5 400 230 50/60 9 MCP-S5/400 230V 2CMA103214R1000 1 8.6
400 6 MCP-S5/400 400V 2CMA103215R1000
2 1 3 2 500 4 5
3MCP-S5/400 500V 4 6 5
7 2CMA103216R1000
690 5 MCP-S5/400 690V 2CMA103217R1000
1000 1 MCP-S5/400 1000V 2CMA103218R1000
11
B
264
155
180
264
C
10/175
—
Socket outlet for wall mounting
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+N+PE
5 250 230 50/60 9 FCW-S5/250 230V 2CMA103444R1000 1 12.0
400 6 FCW-S5/250 400V 2CMA103445R1000
500 7 FCW-S5/250 500V 2CMA103446R1000
690 5 FCW-S5/250 690V 2CMA103447R1000
10
1000 1 FCW-S5/250 1000V 2CMA103448R1000
3L+PEN
4 400 230 50/60 9 FCW-S4/400 230V 2CMA103449R1000 1 11.5
400 6 FCW-S4/400 400V 2CMA103450R1000
500 7 FCW-S4/400 500V 2CMA103451R1000
690 5 FCW-S4/400 690V 2CMA103452R1000
1000 1 FCW-S4/400 1000V 2CMA103453R1000
3L+N+PE
1 1 2 5 2 3400 230 3 4
50/60 9 4 5 230V
FCW-S5/400 5 6
2CMA103454R1000 1 6 12.0 7
400 6 FCW-S5/400 400V 2CMA103455R1000
500 7 FCW-S5/400 500V 2CMA103456R1000
A 690 5 FCW-S5/400 690V 2CMA103457R1000
1000 1 FCW-S5/400 1000V 2CMA103458R1000
221 221
447 447
B 65 65
45-66
45-66
A A
262
262
10°
10°
11 140 11 140 ø9 ø9
140 140
182 182 174 174
zugänglich gemacht werden.
A
er & Stoecklin AG. Sie darf
A
D
10/176 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Socket outlet for wall mounting
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 250 230 50/60 9 FCPA-S4/250 230V 2CMA103399R1000 1 10.3
400 6 FCPA-S4/250 400V 2CMA103400R1000
500 7 FCPA-S4/250 500V 2CMA103401R1000
FCPA-S5/250 400V
690 5 FCPA-S4/250 690V 2CMA103402R1000
1000 1 FCPA-S4/250 1000V 2CMA103403R1000
3L+N+PE
5 250 230 50/60 9 FCPA-S5/250 230V 2CMA103404R1000 1 10.8
400 6 FCPA-S5/250 400V 2CMA103405R1000
500 7 FCPA-S5/250 500V 2CMA103406R1000
690 5 FCPA-S5/250 690V 2CMA103407R1000
10
3L+PEN
4 400 230 50/60 9 FCPA-S4/400 230V 2CMA103409R1000 1 10.3
400 6 FCPA-S4/400 400V 2CMA103410R1000
500 7 FCPA-S4/400 500V 2CMA103411R1000
690 5 FCPA-S4/400 690V 2CMA103412R1000
1000 1 FCPA-S4/400 1000V 2CMA103413R1000
3L+N+PE
5 400 230 50/60 9 FCPA-S5/400 230V 2CMA103414R1000 1 10.8
400 6 FCPA-S5/400 400V 2CMA103415R1000
500 7 FCPA-S5/400 500V 2CMA103416R1000
690 5 FCPA-S5/400 690V 2CMA103417R1000
1 2 3 1000 4 1 5
FCPA-S5/400 1000V 6
2CMA103418R1000 7 8
A
180
240
155
11
B
155
180
432
15° 221
och Dritten zugänglich gemacht werden.
der Rauscher & Stoecklin AG. Sie darf
—
Socket outlet for panel mounting
B-Line
IP67. Watertight
Aluminum housing. Designed for high temperature.
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
FCP-S5/250 400V 4 250 230 50/60 9 FCP-S4/250 230V 2CMA103359R1000 1 6.8
400 6 FCP-S4/250 400V 2CMA103360R1000
500 7 FCP-S4/250 500V 2CMA103361R1000
690 5 FCP-S4/250 690V 2CMA103362R1000
1000 1 FCP-S4/250 1000V 2CMA103363R1000
3L+N+PE
5 250 230 50/60 9 FCP-S5/250 230V 2CMA103364R1000 1 7.3
400 6 FCP-S5/250 400V 2CMA103365R1000
500 7 FCP-S5/250 500V 2CMA103366R1000
690 5 FCP-S5/250 690V 2CMA103367R1000
10
1000 1 FCP-S5/250 1000V 2CMA103368R1000
3L+PEN
4 400 230 50/60 9 FCP-S4/400 230V 2CMA103369R1000 1 6.8
400 6 FCP-S4/400 400V 2CMA103370R1000
500 7 FCP-S4/400 500V 2CMA103371R1000
690 5 FCP-S4/400 690V 2CMA103372R1000
1000 1 FCP-S4/400 1000V 2CMA103373R1000
3L+N+PE
5 400 230 50/60 9 FCP-S5/400 230V 2CMA103374R1000 1 7.3
400 6 FCP-S5/400 400V 2CMA103375R1000
500 7 FCP-S5/400 500V 2CMA103376R1000
690 5 FCP-S5/400 690V 2CMA103377R1000
1000 1 FCP-S5/400 1000V 2CMA103378R1000
1 2 3 4 5 6 7 8
A 247 216 A
157 90
B B
min.140
213
127
153
C C
M6
ser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
eichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
127
—
Connector units
with mechanical interlock, CUMI
To ensure maximum safety for users, we can offer special connector
units.
—
Connector unit with mechanical interlock
C-Line
IP55
Steel housing
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 200 230 50/60 9 CUMI-S4/200 230V-9h 2CMA103459R1000 1 25.1
400 6 CUMI-S4/200 400V-6h 2CMA103460R1000
500 7 CUMI-S4/200 500V-7h 2CMA103461R1000
CUMI-S5/200 400V 690 5 CUMI-S4/200 690V-5h 2CMA103462R1000
1000 1 CUMI-S4/200 1000V-1h 2CMA103463R1000
3L+N+PE
5 200 230 50/60 9 CUMI-S5/200 230V-9h 2CMA103464R1000 1 25.3
400 6 CUMI-S5/200 400V-6h 2CMA103465R1000
500 7 CUMI-S5/200 500V-7h 2CMA103466R1000
690 5 CUMI-S5/200 690V-5h 2CMA103467R1000
10
1000 1 CUMI-S5/200 1000V-1h 2CMA103468R1000
3L+PEN
4 250 230 50/60 9 CUMI-S4/250 230V-9h 2CMA103469R1000 1 25.1
400 6 CUMI-S4/250 400V-6h 2CMA103470R1000
500 7 CUMI-S4/250 500V-7h 2CMA103471R1000
690 5 CUMI-S4/250 690V-5h 2CMA103472R1000
1000 1 CUMI-S4/250 1000V-1h 2CMA103473R1000
3L+N+PE
5 250 230 50/60 9 CUMI-S5/250 230V-9h 2CMA103474R1000 1 25.3
400 6 CUMI-S5/250 400V-6h 2CMA103475R1000
500 7 CUMI-S5/250 500V-7h 2CMA103476R1000
690 5 CUMI-S5/250 690V-5h 2CMA103477R1000
1000 1 CUMI-S5/250 1000V-1h 2CMA103478R1000
1 2 3 4 5 6 7 8
350
285
A A
310
60
20-65
11
15
B B
580
610
C C
er Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
ichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
135
15°
E 95
Gewicht 4-pol = 25.1kg E
Gewicht 5-pol = 25.3kg
—
Connector unit with mechanical interlock
B-Line
IP55
Steel housing
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 250 230 50/60 9 CUMI-S4/250 230V-9h 2CMA103479R1000 1 45.6
400 6 CUMI-S4/250 400V-6h 2CMA103480R1000
500 7 CUMI-S4/250 500V-7h 2CMA103481R1000
690 5 CUMI-S4/250 690V-5h 2CMA103482R1000
CUMI-S5/250 400V
1000 1 CUMI-S4/250 1000V-1h 2CMA103483R1000
3L+N+PE
5 250 230 50/60 9 CUMI-S5/250 230V-9h 2CMA103484R1000 1 47.1
400 6 CUMI-S5/250 400V-6h 2CMA103485R1000
500 7 CUMI-S5/250 500V-7h 2CMA103486R1000
690 5 CUMI-S5/250 690V-5h 2CMA103487R1000
10
3L+PEN
4 400 230 50/60 9 CUMI-S4/400 230V-9h 2CMA103489R1000 1 45.6
400 6 CUMI-S4/400 400V-6h 2CMA103490R1000
500 7 CUMI-S4/400 500V-7h 2CMA103491R1000
690 5 CUMI-S4/400 690V-5h 2CMA103492R1000
1000 1 CUMI-S4/400 1000V-1h 2CMA103493R1000
3L+N+PE
5 400 230 50/60 9 CUMI-S5/400 230V-9h 2CMA103494R1000 1 47.1
400 6 CUMI-S5/400 400V-6h 2CMA103495R1000
500 7 CUMI-S5/400 500V-7h 2CMA103496R1000
690 5 CUMI-S5/400 690V-5h 2CMA103497R1000
1000 1 CUMI-S5/400 1000V-1h 2CMA103498R1000
1 2 3 4 5 6 7 8
550 362
A A
515
80
11
15
B B
630
660
C C
r Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
chnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
221
E E
—
Connector units
with block contactor, CUBC
To ensure maximum safety for users, we can offer special connector
units.
10
Protection grade IP55 IP55
Shock resistance IK07 IK07
Ambient temperature °C -40/+70 -40/+70
Insulation resistance (Phase-phase and MOhm >500 >500
phase-earth)
Comparative tracking index of the insert CTI >600 >600
Weight 4 poles (3L+PEN) kg 25.1 45.6
Weight 5 poles (3L+N+PE) kg 25.3 47.1
Connection bolts for cable shoes M8 M10
Max cross section pilot cable, mm2 4 4
conductor (EN 60228 Class 1)
Diameter of cable - normal mm 20-70 20-70
other diameters on request
10/182 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Connector unit with block contactor
C-Line
IP55
Steel housing
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 200 230 50/60 9 CUBC-S4/200 230V 2CMA103499R1000 1 25.1
400 6 CUBC-S4/200 400V 2CMA103500R1000
500 7 CUBC-S4/200 500V 2CMA103501R1000
CUBC-S5/200 400V
690 5 CUBC-S4/200 690V 2CMA103502R1000
1000 1 CUBC-S4/200 1000V 2CMA103503R1000
3L+N+PE
5 200 230 50/60 9 CUBC-S5/200 230V 2CMA103504R1000 1 25.3
400 6 CUBC-S5/200 400V 2CMA103505R1000
500 7 CUBC-S5/200 500V 2CMA103506R1000
690 5 CUBC-S5/200 690V 2CMA103507R1000
10
3L+PEN
4 250 230 50/60 9 CUBC-S4/250 230V 2CMA103509R1000 1 25.1
400 6 CUBC-S4/250 400V 2CMA103510R1000
500 7 CUBC-S4/250 500V 2CMA103511R1000
690 5 CUBC-S4/250 690V 2CMA103512R1000
1000 1 CUBC-S4/250 1000V 2CMA103513R1000
3L+N+PE
5 250 230 50/60 9 CUMI-S5/250 230V 2CMA103514R1000 1 25.3
400 6 CUMI-S5/250 400V 2CMA103515R1000
500 7 CUMI-S5/250 500V 2CMA103516R1000
690 5 CUMI-S5/250 690V 2CMA103517R1000
1000 1 CUMI-S5/250 1000V 2CMA103518R1000
1 2 3 4 5 6 7 8
350 258
A 310 A
60
20-65 11
15
B B
580
610
C C
verständnis weder kopiert noch Dritten zugänglich gemacht werden.
ng bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
135
15°
95
E E
—
Connector unit with circuit breaker
C-Line
IP54
Steel housing
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 200 230 50/60 9 CUCB-S4/200 230V 2CMA103539R1000 1 25.1
400 6 CUCB-S4/200 400V 2CMA103540R1000
500 7 CUCB-S4/200 500V 2CMA103541R1000
690 5 CUCB-S4/200 690V 2CMA103542R1000
CUCB-S5/200 400V
3L+N+PE
5 200 230 50/60 9 CUCB-S5/200 230V 2CMA103543R1000 1 25.3
400 6 CUCB-S5/200 400V 2CMA103544R1000
500 7 CUCB-S5/200 500V 2CMA103545R1000
690 5 CUCB-S5/200 690V 2CMA103546R1000
3L+PEN
10
4 250 230 50/60 9 CUCB-S4/250 230V 2CMA103547R1000 1 25.1
400 6 CUCB-S4/250 400V 2CMA103548R1000
500 7 CUCB-S4/250 500V 2CMA103549R1000
690 5 CUCB-S4/250 690V 2CMA103550R1000
3L+N+PE
5 250 230 50/60 9 CUCB-S5/250 230V 2CMA103551R1000 1 25.3
400 6 CUCB-S5/250 400V 2CMA103552R1000
500 7 CUCB-S5/250 500V 2CMA103553R1000
690 5 CUCB-S5/250 690V 2CMA103554R1000
1 2 3 4 5 6 7 8
A 350 A
285
310
60
20-65
11
15
B B
C C
610
580
ohne unser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
Diese Zeichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
135
E E
15° Gewicht 4-pol = 25.1kg
95 Gewicht 5-pol = 25.3kg
—
Connector unit with circuit breaker
B-Line
IP54
Steel housing
Weight
Terminals/ Pkg pkg
Poles Ampere Voltage Frequency Hour Type Order Code qty (1pce)
A V Hz kg
3L+PEN
4 250 230 50/60 9 CUCB-S4/250 230V 2CMA103555R1000 1 45.6
400 6 CUCB-S4/250 400V 2CMA103556R1000
500 7 CUCB-S4/250 500V 2CMA103557R1000
690 5 CUCB-S4/250 690V 2CMA103558R1000
3L+PEN
10
3L+N+PE
5 400 230 50/60 9 CUCB-S5/400 230V 2CMA103567R1000 1 47.1
400 6 CUCB-S5/400 400V 2CMA103568R1000
500 7 CUCB-S5/400 500V 2CMA103569R1000
690 5 CUCB-S5/400 690V 2CMA103570R1000
1 2 3 4 5 6 7 8
A 350 A
285
310
60
20-65
11
15
B B
C C
610
580
ohne unser Einverständnis weder kopiert noch Dritten zugänglich gemacht werden.
Diese Zeichnung bleibt geistiges Eigentum der Rauscher & Stoecklin AG. Sie darf
D D
135
E E
15° Gewicht 4-pol = 25.1kg
95 Gewicht 5-pol = 25.3kg
—
Electrical installation solutions for buildings
Light switches and socket outlets
Index
carat®1
Busch-dynasty®2
pure stainless steel 3
solo®4
Busch-axcent®5
future® linear 6
basic55®7
Sky Niessen 8
Impressivo9
Swing®L10
Zenit11
Mylos®12
Chiara13
Unno14
IVIE15
Millenium16
11
Concept bs 17
Kalo18
Ocean19
Movement detectors 20
11/2 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
Light switches and socket outlets
A piece of design in your interior.
Discover the wide range of designs, colours, finishes and functions and find
the best solutions with innovative technology. Let modern light switches
highlight the individual design of your living space.
VDE-standard
01 02 03 04
11
05 06 07 08
09 10 11
11/3
—
Light switches and socket outlets
A piece of design in your interior.
British standard
12 13 14
11
IT-standard
18
15 16 17
For design range availability on the local market contact your local sales team.
11/4 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
carat®
Everyday indulgence.
Extraordinary and distinct design, of the highest quality. Each piece becomes a unique object of any
interior. It attracts attention and that is the point. Solid frames made from bronze, polished steel or
glossy glass, show immediately their real value and an exquisite owner’s taste. The aesthetics,
together with innovative functions make every day luxurious.
01 02 03
11
04 05 06
01 ivory white / bronze
02 studio white / glass black
03 anthracite / stainless steel
04 studio white / chrome Materials
05 ivory white / gold UV-resistant, free of PVC and halogen.
06 studio white / white glass Frame: genuine materials.
11/5
—
carat®
Selected functions.
01 02 03 04 05 06 07
08 09 10 11 12 13 14
15 16 17 18 19 20 21
11
02 Rocker switch 2gang 13 Busch-Blind comfort switch
03 Busch Universal Rotary Dimmer 14 Comfort timer
04 Touch dimmer 15 Room thermostat with display
05 Busch-Comfort switch 16 Busch-Infoline® alarm insert
06 Busch-steplight® 17 Busch-AudioWorld® Busch-Radio iNet
07 Busch-Protector® SCHUKO® socket outlet 18 Antenna socket for radio/TV/satellite
with overvoltage protection 19 Universal data connection box
08 SCHUKO® USB socket outlet 20 Stereo loudspeaker connecting box
09 Socket outlet with earthing pin 21 KNX sensor, for more KNX products see part 12 of the
10 Switched socket outlet BS standard catalogue - Intelligent Building Solutions
11 Blind switch with rotary knob
05
1 to 4gang cover frame for horizontal
and vertical installation.
04 01 Side view, 11 mm x 107 mm
02 107 mm x 107 mm
03 03 107 mm x 178 mm
04 107 mm x 249 mm
05 107 mm x 320 mm
01 02
—
carat®
Rocker switches / push switches
2400/6/6US-101-500 2CKA001022A0663 10
1gang 2way
1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
2000/6 US-500 2CKA001012A2198 10/100 Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
2gang 1way
2000/5 US-500 2CKA001012A1150 10/100
Rocker Switch Mechanism 1) 2)
DP, 1gang 1way
DP, 1gang 2way 2)
For switching high loads.
2000/6/2 US 2CKA001012A0954 10 Rated voltage: 250 V~
Rated current: 16 AX
1gang Protection class (Device): IP 20IEC 60669-1
2000/7 US-500 2CKA001012A2199 10/100
2000/2 US-101-500 2CKA001012A2193 10/100
DP, 1gang 1way 1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
2000/2 US-500 2CKA001012A2196 10/100 or 3060 wallbox concrete)
2)
Also for switching SCHUKO® socket outlets.
SP, 1gang 1way switch
2000/1 US-500 2CKA001012A2059 10/100
11
1gang
1gang 2way 2)
2400/7 US-500 2CKA001012A2236 10
2000/6 USGL-500 2CKA001012A2194 10/100
1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall 2gang 1way
or 3060 wallbox concrete)
2000/5 USGL 2CKA001012A1135 10
1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Rocker Switch Mechanism 1) Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
2gang 2way or 3060 wallbox concrete)
With screwless terminals. 2)
Replacement lamps 8360, 8362, and 8363 and LED inserts.
Rated voltage: 250 V~
Rated current: 10 AX
Protection class (Device): IP 20IEC 60669-1 Rocker Switch Mechanism, control 1)
2gang 1way
2000/6/6US-101-500 2CKA001011A0928 10/100 with LED,
1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073, Rated voltage: 250 V~
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall Rated current: 16 AX
or 3060 wallbox concrete) Protection class (Device): IP 20IEC 60669-1
—
carat®
Rocker switches / push switches
2000/2 UK 2CKA001022A0656 10
1)
With 1 mA neon lamp. Push-switch mechanism 1)
2)
Only in conjunction with standard flush-mounting boxes according to DIN 49073, SP, 1gang 2way
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall Can be wired for normally open contacts (stand-by
or 3060 wallbox concrete) current) or normally closed contacts (operating current).
3)
Illuminable by using lamps 8360, 8362, 8363, 8365, 8366, and 8367 and LED inserts. With N terminal.
Rated voltage: 250 V~
Rated current: 10 A
Rocker Switch Mechanism, control 1) 2) 3)
Protection class (Device): IP 20IEC 60669-1
1gang 2way with N-terminal
With neon lamp. 2020 US-206-500 2CKA001413A1104 10/100
Rated voltage: 250 V~, 1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Rated current: 16 AX Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
Protection class (Device): IP 20IEC 60669-1 or 3060 wallbox concrete)
11
2400/6 USK-500 2CKA001022A0661 10
1)
With 1 mA neon lamp. Rocker
2)
Only in conjunction with standard flush-mounting boxes according to DIN 49073, For flush-mounted switch 1g1w, 1g2w, intermediate,
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall push switch.
or 3060 wallbox concrete) Protection class (Device): IP 20
3)
Illuminable by using lamps 8360, 8362, 8363, 8365, 8366, and 8367 and LED inserts.
—
carat®
Rocker switches / push switches
anthracite 2520 TR-81 2CKA001751A3196 10/100 anthracite 1764 NLI/KI-81 2CKA001731A3998 10/100
ivory white 2520 TR-82 2CKA001751A3197 10/100 ivory white 1764 NLI/KI-82 2CKA001731A3999 10/100
studio white 2520 TR-84 2CKA001751A3199 10/100 studio white 1764 NLI/KI-84-500 2CKA001731A4002 10/100
1)
For compatible lettering software, visit www.BUSCH-JAEGER-labelingtool.com.
2)
Illumination using neon lamp 8353 or incandescent lamp 8344-1 and LED inserts.
11/9
—
carat®
Rocker switches / push switches
11
For insert 2025 U. Suitable for cards sized 54 x 86 mm.
Switch rocker with marking The inner part of the cover plate is made of light-
with small red spherical cap conducting plastic, so that the card slot is illuminated.
With marking "Heizung". Protection class (Device): IP 20
As cover for flush-mounted 1gang 1way, 1gang 2way
switch, intermediate switch, push-button and control anthracite 1792-81 2CKA001710A3639 10
switch 1gang 2way. As cover for 2-pole or 3-pole flush- ivory white 1792-82 2CKA001710A3640 10
mounted on-off switch and 2-pole control on-off switch.
studio white 1792-84 2CKA001710A3641 10
Protection class (Device): IP 20
anthracite 1789 H-81 2CKA001751A2929 10
Pull switch 1)
ivory white 1789 H-82 2CKA001751A2743 10
SP, with normally open contact (operating current)
studio white 1789 H-84 2CKA001751A2751 10 With 2-metre pull cord, red handle, and red neon
indicator.
Rated voltage: 250 V~
Card switch 10 A 1)
Rated current: 10 A
SP, with normally open contact (operating current)
Illuminable. 2020/01 US-101 2CKA001413A1112 10
With N terminal. 1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Rated voltage: 250 V~, Rated current: 10 A Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
Protection class (Device): IP 20IEC60669-1, British or 3060 wallbox concrete)
Standard EN 60669-1
2025 U 2CKA001012A1713 10
Pull switch 1)
Mounting 35 mm deep flush 1gang SP, break contact
boxes: or Dual Box 3070-2/35 BSDB. With 2-metre pull cord, red handle, and red neon
2gang product 2gang combination with adapter plate indicator.
combinations: APBS in Dual Box only. Rated voltage: 250 V~
Rated current: 10 A
delivery form: Adapter plate APBS to be ordered separate.
1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073, 2020/10 US-101 2CKA001413A1111 10
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall 1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
or 3060 wallbox concrete) Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
—
carat®
Rocker switches / push switches Dimmers
With zero position. For Friends of Hue smart switch insert 6716 U-500.
For insert 2710 U. Can be combined with switch ranges carat®, Busch-
Protection class (Device): IP 20 dynasty®, pure stainless steel, solo®, Busch-axcent® and
future® linear.
anthracite 2542 DR/01-81 2CKA001710A3644 10
ivory white 2542 DR/01-82 2CKA001710A3645 10
anthracite 6736 FoH-81 2CKA006730A0133 1
studio white 2542 DR/01-84 2CKA001710A3646 10
ivory white 6736 FoH-82 2CKA006730A0134 1
studio white 6736 FoH-84 2CKA006730A0136 1
Cover plate
with rotary control, with marking
As cover for flush mounted three-step rotary switch.
Without zero position.
For insert 2710/1 U.
Protection class (Device): IP 20
Cover plate 1)
for pull switch 2610/6 UC-xx, 2610/6 UJ-xx
With screw-type terminal
Protection class (Device): IP 20
—
carat®
Dimmers
11
British Standard EN 60669-2-1 Protection class (Device): IP 20
Temperature range (Device): 0 °C to 35 °CIEC 60669-2-1,
British Standard EN 60669-2-1
6523 U-102-500 2CKA006512A0335 1/10
1)
Illuminable with neon lamp. Neon lamp included in delivery with cover plate.
2)
In the case of conventional transformers, take ~20% transformer loss into account. 6523 UR-103-500 2CKA006512A0345 1/10
3)
In case of electronic transformers, 5 % transformer losses. 1)
Illuminable with neon lamp. Neon lamp included in delivery with cover plate.
4)
Also applicable for 1gang 2way installations. 2)
In the case of conventional transformers, take ~20% transformer loss into account.
5)
Provided with terminal for net disconnection devices. 3)
In case of electronic transformers, 5 % transformer losses.
6)
Only in conjunction with standard flush-mounting boxes according to DIN 49073, 4)
Also applicable for 1gang 2way installations.
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall 5)
Provided with terminal for net disconnection devices.
or 3060 wallbox concrete) 6)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
7)
Recommendation: Please use loads and types of one producer. Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
7)
Recommendation: Please use loads and types of one producer.
11/12 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
carat®
Dimmers
—
carat®
Dimmers
11
Busch-rotary dimmer 1) 2) 3) 4) 5) 6)
flush mounted, RC, 40-420 W Busch-rotary dimmer 1) 2) 3) 4) 5)
With rotary control, soft-catch and with trailing edge flush mounted, RLC, 60-420 W
control. with soft-catch
For incandescent lamps, 230 V tungsten halogen With intelligence for universal operation.
lamps and low-voltage halogen lamps with electronic For incandescent lamps, 230 V tungsten halogen lamps
transformers. and low-voltage halogen lamps with conventional
Low-noise, short-circuit-proof, overload-protected. transformers or electronic transformers.
Without cover plate. Short-circuit-proof, overload-protected.
Rated voltage: 230 V~, +10 % / -10 % Capacity expansion via output-side, parallel connectable
Rated frequency: 50 Hz load line with a power module 6594 U up to 735 W/VA
Rated power: 40 - 420 W/VA possible. Operation via rotary-type remote control
IEC 60669-2-1, British Standard EN 60669-2-1 6592 U possible. Without cover plate.
Rated voltage: 230 V~, +10 % / -10 %
Rated frequency: 50 Hz - 60 Hz
Rated power: 60 - 420 W/VA
6513 U-102-500 2CKA006513A0586 1/10 IEC 60669-2-1, British Standard EN 60669-2-1
1)
Not suitable with conventional transformers.
2)
Illuminable with neon lamp. Neon lamp included in delivery with cover plate.
3)
In case of electronic transformers, 5 % transformer losses.
4)
Provided with terminal for net disconnection devices. 6591 U-101-500 2CKA006513A0588 1/10
5)
Also applicable for 1gang 2way installations. 1)
Illuminable with neon lamp 3855. Neon lamp included in delivery with cover plate.
6)
Only in conjunction with standard flush-mounting boxes according to DIN 49073, 2)
In case of electronic transformers, 5 % transformer losses.
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall 3)
In the case of conventional transformers, take ~20% transformer loss into account.
or 3060 wallbox concrete) 4)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
5)
Cannot be combined with a 2way switch.
—
carat®
Dimmers
—
carat®
Dimmers
11
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
flush mounted, RC, 45-315 W
or 3060 wallbox concrete)
For switching and dimming 2 independent devices.
With trailing edge control.
Busch-rotary dimmer 1) 2gang 1way
flush mounted, DALI, with internal power supply For incandescent lamps, 230 V tungsten halogen
For DALI broadcast service (via central telegram). lamps and low-voltage halogen lamps with electronic
With integrated DALI power adaptor. transformers.
For switching and dimming up to 64 DALI- devices Compatible with control covers 6545-xxx.
like electronic ballasts and transformers with DALI- Without cover, without cover plate.
interface. Outputs: 2 independent dimmer channels.
With rotary control and ON/OFF push operation. Rated power: 40-315 W/VA per channel.
With electronic short-circuit protection. Rated voltage: 230 V~, +10 % / -10 %
With electronic overload protection. Rated frequency: 50 Hz - 60 HzIEC 60669-2-1, British
Brightness power-on level and backround brightness Standard EN 60669-2-1
level adjustable, buffered.
With integrated LED illumination for orientation.
Color of orientation light adjustable (18 presets and 6565 U-500 2CKA006565A0057 1/10
OFF). 1)
Not suitable with conventional transformers.
Up to 5 potentiometers are connectable in parallel. 2)
In case of electronic transformers, 5 % transformer losses.
Up to 3 potentiometers are connectable in parallel in 3)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
active mode. Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
Not suitable for combining with other DALI sensors or or 3060 wallbox concrete)
central units of other manufacturers.
4)
Does not provide an extension input.
DALI-voltage: 15,5 V=
Rated current: max. 75 mA
Power consumption: < 2,5 W
Number of DALI-units:
37 in case of one active power-potentiometer
in case of three active power-potentiometer in parallel
connection: 111
Active mode: the potentiometer is supporting the
necessary control circuit for other DALI-devices.
Passive mode: the potentiometer is suitable as
additional operation point.
Max. DALI-cable length: 300 m (1,5 - 2,5 mm²).
Without cover plate.
Rated voltage: 230 V~, +10 % / -10 %
Rated frequency: 50 Hz - 60 Hz
Protection class (Device): IP 20
Temperature range (Device): 0 °C to 35 °C
2117/11 U-500 2CKA006599A2988 1
1)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
11/16 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
carat®
Dimmers
6805 U.
Rated voltage: 230 V~, +10 % / -10 % 6550 U-101-500 2CKA006550A0042 1
Rated frequency: 50 Hz 1)
Non-illuminable.
Rated power: 60 - 420 W/VA
2)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
IEC 60669-2-1, British Standard EN 60669-2-1 Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
3)
with integrated making-current limiter
—
carat®
Dimmers Movement detectors / comfort switches
11
Temperature range (Device): -25 °C to 55 °C60669-2-1
—
carat®
Movement detectors / comfort switches
—
carat®
Movement detectors / comfort switches
11
Temperature range (Device): 0 °C to 35 °C Rated power: 2300 VA
Temperature range (Device): -5 °C to 45 °C
anthracite 6800-81-104M 2CKA006800A2269 1
Dimensions: (L x W x D): 71 mm x 71 mm x 32 mm
ivory white 6800-82-104M 2CKA006800A2100 1 Mounting depth: 31 mm
studio white 6800-84-104M 2CKA006800A2102 1/10 DIN EN 60669-2-1
1)
installation: slide switch top. LEDi
2)
Please order the respective flush-mounted insert separately.
6440/01 U-500 2CKA006400A0085 1
Cover plate
Proximity switch Universal e-contact insert 1)
For proximity switch 6406 U. 2-wire connection (neutral conductor not required)
For switching lighting systems.
For Busch-Comfort switch control element
6815-...-101-500. For Busch-Presence detector sensor
6813-…-102-500. Can be combined with Universal-
anthracite 6476-81 2CKA006470A0007 1/10 Slave insert 6440/05 U-500. Operation in 1gang 2way
ivory white 6476-82 2CKA006470A0003 10 installations via push switch-unit for combination
with flush-mounted units. Operation also possible via
studio white 6476-84 2CKA006470A0004 10 conventional push buttons (2020 US, 2021/6 UK).
2 supplementary inputs via 127 V push switch
(e.g. 2020 US), central disablement of all outputs
possible, supplementary IR remote control is possible
via IR flying receiver 6045 E-101
Rated voltage: 230 V~, +10 % / -10 %
Rated frequency: 50 Hz - 60 Hz
Outputs: 1x Normally open contact, potential-bound
Suitable for: 230 V~ LEDi
Rated power: 2 - 80 W/VA
Suitable for: 230 V incandescent lamps/230 V halogen
lamps
Rated power: 20 - 180 W
Suitable for: Low voltage halogen lamps operated by
transformers.
Rated power: 20 - 180 VA
Temperature range (Device): -5 °C to 45 °C
Dimensions: (L x W x D): 71 mm x 71 mm x 32 mm
Mounting depth: 31 mm
DIN EN 60669-2-1
—
carat®
Movement detectors / comfort Blind control / timers
switches
—
carat®
Blind control / timers
11
IEC60669-1, British Standard EN 60669-1 Without an extension input.
Power reserve of 45 minutes (maintenance-free as
DP 5) capacitor).
2712 USL-101 2CKA001101A0872 10 Rated voltage: 230 V~, +10 % / -10 %
Rated frequency: 50 Hz
SP, N, E Outputs: 2x Normally open contact
Rated current: 1.3 A, cos φ 0.5
2713 USL-101 2CKA001101A0880 10 Rated power: 300 VA
1)
For installation on British Standard wallboxes please use adapter plate APBS
(6599-0-2813). (Depth of box 60 mm.) Temperature range (Device): 0 °C to 35 °C
2)
Blind switches/push switches prevents fast change over between operating
directions. 6419 U 2CKA006410A0390 1/10
3)
Use the cylindrical lock according to the enclosed drawing. 1)
Pertinent cover plates 6436-xx.
4)
See semi-cylindrical lock. 2)
N-conductor connection may be required for operation with blind and roller
5)
Also suitable for controlling direct voltage drives. blind drives with electronic limit switch shut-off. If no N-conductor is available,
capacitor set 6498 can be used.
3)
Only suitable for single unit control.
Blind switch insert 1) 2) 3) 4)
For profile semi-cylindrical lock/push-button.
Delivered without cylindrical lock. Basic blind insert 1) 2)
Rated voltage: 250 V~ 2-wire blind insert
Rated current: 10 A Suitable for blind and roller blind drives with mechanical
Protection class (Device): IP 20 or electronic limit switch shut-off.
British Standard EN 60669-1, IEC60669-1 Suitable for operation without neutral conductor.
Without an extension input.
DP 5) For control cover 6430-xx-xxx.
2722 USL-101 2CKA001101A0898 10 For standard timer control element 6456-101.
Running time: 3 min
SP, N, E Rated voltage: 230 V~, +10 % / -10 %
Rated frequency: 50 Hz
2723 USL-101 2CKA001101A0906 10 Outputs: 2x Normally open contact
1)
For installation on British Standard wallboxes please use adapter plate APBS Rated current: 3 A, cos φ 0.5
(6599-0-2813). (Depth of box 60 mm.) Rated power: 690 VA
2)
Blind switches/push switches prevents fast change over between operating
directions.
Temperature range (Device): 0 °C to 35 °C
3)
Use the cylindrical lock according to the enclosed drawing.
4)
See semi-cylindrical lock. 6418 U-500 2CKA006410A0376 1/10
5)
Also suitable for controlling direct voltage drives.
Mounting 35 mm deep flush 1gang
boxes: or Dual Box 3070-2/35 BSDB.
2gang product 2gang combination with adapter plate
combinations: APBS in Dual Box only.
1)
N-conductor connection required for operation with control cover 6430-7x,
illuminated.
2)
N-conductor connection may be required for operation with blind and roller
blind drives with electronic limit switch shut-off. If no N-conductor is available,
capacitor set 6498 can be used.
11/22 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
carat®
Blind control / timers
1)
Compatible with types 6411 U/x.
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
Brightness sensor
For insert 6411U/S-101. Rocker
With 2 m connecting cable. with marking
Measuring range: 15-50,000 lux. As cover for flush-mounted blind control switch/push
switch.
For inserts 2000/4 and 2020/4 US.
Protection class (Device): IP 20
6414-101 2CKA006410A0389 1/10
anthracite 1785 JA-81 2CKA001751A2934 10
Sun sensor ivory white 1785 JA-82 2CKA001751A2748 10
For insert 6411U/S-101. studio white 1785 JA-84-500 2CKA001751A3088 10/100
Measuring range: 5-50,000 lux.
Cover plate
with rotary control, with marking
As cover for flush-mounted blind control switch/push
6482 2CKA006410A0203 1 switch.
For inserts 2712 U, 2713 U and 2722 U, 2723 U.
Protection class (Device): IP 20
Cover plate 1)
with labelling field
With marking.
For half-cylindrical type switches and blind control
switch/push-switch.
For inserts 2733 USL-101 and 2712 USL-101, 2713 USL-101,
2722 USL-101, 2723 USL-101.
Protection class (Device): IP 20
anthracite 1755 SL/PZ-81-101 2CKA001710A3626 10
ivory white 1755 SL/PZ-82-101 2CKA001710A3157 10
studio white 1755 SL/PZ-84-101 2CKA001710A3175 10
1)
For compatible lettering software, visit www.BUSCH-JAEGER-labelingtool.com.
11/23
—
carat®
Blind control / timers
11
conditioning.
Standard timer control element 1)
Programming possible only with control element
For manual and time-controlled switching of blinds and
attached and energized.
roller blinds.
6 switching times per day can be user-defined for each
With dusk to dawn program including (Astro-program)
day of the week.
Individual Astro adjustment and Astro blocking time.
Astro switching times and switching times can be
The controlled devices can be manually operated at any
combined.
time.
When combined with LED dimmer 6524 U, Busch-
Simple setting via high-resolution display with
Universal master dimmer insert 6593 U or Busch-
background illumination.
Memory touch-type controller 6550 U-101, the
With preset switching times/date/time.
brightness of the lighting can be adjusted for each ON
Factory-set switching times can be individually
switching time.
adjusted.
For Busch-Blind control II insert 6411 U-101,
Automatic switchover from summer time to winter time
6411 U/S-101.
(switch-off function).
For Busch-Universal relay switch insert 6401 U-102.
Switching times/programme are safely stored in the
For Busch-Universal master dimmer insert 6593 U.
event of a mains power failure.
For LED dimmer insert 6524 U and 6526 U..
Power reserve for time and date > 10 years.
For Busch-Memory touch-type controller 6550 U-101.
Simple toggling between manual/automatic/vacation
Temperature range (Device): 0 °C to 35 °C
modes.
Programming possible only with control element 6455-101-500 2CKA006410A0399 1/10
attached and energized. 1)
See respective cover plates 6435-xx.
2 switching times per day can be user-defined for each
day of the week.
Astro switching times and switching times can be Time switch mechanism 16 A 1) 2)
combined. DP, break contact for staircases, exterior lighting, fans,
For basic blind insert 6418 U. etc.
Temperature range (Device): 0 °C to 35 °C Running time: 15 min
For time-programmed switching of electrical
6456-101 2CKA006410A0398 1/10
consumers.
1)
See respective cover plates 6435-xx. Rated voltage: 230 V~, +10 % / -10 %
Rated current: 16 A, cos φ 0.25
Protection class (Device): IP 20
1070 U 2CKA001043A0025 1/10
1)
For screw-fixing only
2)
Only in conjunction with standard flush-mounting boxes according to DIN 49073,
Part 1, erect or Busch-Jaeger No. 3040 wallbox stonework, 3050 wallbox cavity wall
or 3060 wallbox concrete)
11/24 E L E C T R I C A L I N S TA L L AT I O N S O L U T I O N S F O R B U I L D I N G S 2CHC 420 001 C0202
—
carat®
Blind control / timers Socket outlets
—
carat®
Socket outlets
11
1)
Increased shock protection .
1)
Increased shock protection .
—
carat®
Socket outlets
—
carat®
Socket outlets
Euro American socket outlet with earth, 16 A FI-SCHUKOMAT, SCHUKO® socket outlet (RCD) 1) 2) 3)
1gang with earth leakage circuit breaker
With screw-type terminals. Shuttered.
Without claws. DP cut off (P,N)
Rated voltage: 250 V~ Without PE monitoring.
Rated current: 16 A With connecting conductor and protection of
downstream socket outlets.
anthracite 2196 EUC-81-500 CBA019A082S4010 10/40 Rated fault current: 30 mA.
ivory white 2196 EUC-82-500 CBA019A082S3010 10/40 With fixing claws.
Rated frequency: 45-60 Hz.
studio white 2196 EUC-84-500 CBA019A082S1010 10/40
Rated voltage: 230 V~
Rated current: 16 A
SCHUKO® socket outlet without claw 1) Protection class (Device): IP 20
shuttered Temperature range (Device): -25 °C to 40 °C
Without claws. With screwless terminals. anthracite 3120 EUCB-81 2CKA003116A0667 1/10
DP (2 P + E)
ivory white 3120 EUCB-82 2CKA003116A0661 1
Rated voltage: 250 V~
Rated current: 16 A studio white 3120 EUCB-84 2CKA003116A0662 1
Protection class (Device): IP 20 1)
Connecting terminals approved in accordance with VDE 0620-1 as connectors.
anthracite 20 EUCRB-81 2CKA002013A5437 10/100
2)
Protective measure according to VDE 0100; can be proven or checked using the
Profitest 0100S testing device, for example.
ivory white 20 EUCRB-82 2CKA002013A5438 10/100 3)
Increased shock protection .
studio white 20 EUCRB-84-500 2CKA002013A5441 10/100
1)
Increased shock protection . Buschmat® FI - Insert 1)
with earth leakage breaker with connecting conductor
11
Protection of downstream consumers.
SCHUKO® socket outlet 1) 2)
Rated fault current: 30 mA.
shuttered
DP cut off (P,N)
With screw-type terminals.
With fixing claws.
DP (2 P + E)
Rated frequency: 45-60 Hz.
Rated voltage: 250 V~
Rated voltage: 230 V~
Rated current: 16 A
Rated current: 16 A
Protection class (Device): IP 20
Protection class (Device): IP 20
anthracite 2300 EUCB-81 2CKA002013A5448 10 Temperature range (Device): -25 °C to 40 °C
ivory white 2300 EUCB-82 2CKA002013A5449 10/100 anthracite 3151 UC-81 2CKA003117A0009 1/10
studio white 2300 EUCB-84 2CKA002013A5451 10/100 ivory white 3151 UC-82 2CKA003117A0005 1/10
1)
Increased shock protection . studio white 3151 UC-84 2CKA003117A0006 1/10
2)
With screw-type terminals
1)
Protective measure according to VDE 0100; can be proven or checked using the
Profitest 0100S testing device, for example.
Busch-Socket outlet 1)
shuttered
SCHUKO® socket outlet 1)
With screwless terminals.
with hinged lid and internal increased shock protection
DP (2 P + E)
Shuttered.
With eject mechanism.
With screwless terminals.
Rated voltage: 250 V~
DP (2 P + E)
Rated current: 16 A
with hinged lid
Protection class (Device): IP 20
Rated voltage: 250 V~
anthracite 20 EUCBDR-81 2CKA002013A5415 10 Rated current: 16 A