EURO-DIESEL
DYNAMIC ROTARY UPS - DRUPS
PRESENTATION TO IDEAL SOLUTIONS
OMAN
JULY 2018
Bernard Hanssens
AGENDA
1. COMPANY PRESENTATION
2. DRUPS SYSTEM
3. DRUPS – ADDED VALUE FOR THE CLIENTS
4. DRUPS CONFIGURATIONS
5. DRUPS APPLICATIONS
6. LOCAL PRESENCE IN ME – AFTER SALES SUPPORT
7. EURO-DIESEL REFERENCE IN ME
8. SOME SPECIAL INTERNATIONAL REFERENCES
EURO DIESEL Template
2
1. COMPANY PRESENTATION
3
EURO-DIESEL HQ, BELGIUM
EURO-DIESEL
Holland • Private company
• Factory in Belgium and Germany
Belgium • Established in 1989
• 330 Employees
• 12 offices: Belgium (HQ), Germany, UK, France,
USA, Singapore, Turkey, Chili, Russia, Brazil, Qatar,
France UAE + Presence in KSA
• Worldwide presence
• 24/7 After Sales service support worldwide
• Focus on power quality solutions
EURO DIESEL Template
4
WORLDWIDE PRESENCE
EURO-DIESEL
Distributors
EURO DIESEL Template
5
THE FACTORY
The Facility:
• 6300 M²
• Production capacity > 300 systems
• 18 Test stands
• Indoor enclosure assembly
• 50 & 60 Hz testing
• Load banks > 18 MW
• Load banks & recordings, software operated
EURO DIESEL Template
6
ISO CERTIFIED
EURO DIESEL Template
7
2. DRUPS SYSTEM
8
Static vs Dynamic UPS Solution
CHOKE COIL ATS STATIC UPS POWER DISTRIBUTION PANELS
Mains Load
BATTERY ROOM
Diesel Generator System
9
BUILDING OF A NO-BREAK KS® SYSTEM
EURO DIESEL Template
10
INSTALLATION OF A DRUPS
IN A ROOM:
IN A FACTORY-BUILT ENCLOSURE:
EURO DIESEL Template
11
DRUPS – HOW IT WORKS
12
DRUPS – CONTROL PANEL
13
DRUPS – CONTROL PANEL
14
3. DRUPS – ADDED VALUE
15
SIMPLE DESIGN
SIMPLE ELECTRICAL DESIGN
EURO DIESEL Template
16
SIMPLE DESIGN
SIMPLE MECHANICAL INSTALLATION
STATIC UPS =
Spark-proof Lighting
Static UPS Modules Air Conditioning MANY ELEMENTS
REQUIRED
Fire Protection PFC
& Security
Standby Generator
Standby Battery Rooms
REPLACE THEM ALL BY 1 DRUPS
DRUPS = 1 SIMPLE MACHINE
EURO DIESEL Template
17
REDUCED FOOTPRINT
EURO DIESEL Template
18
COST SAVINGS
LOW CAPEX
• No Standby Battery rooms and related infrastructure:
Air conditioning for battery rooms
Special fire protection system
Spark proof lighting
…
• No Static UPS Modules
• No Capacitor banks
• No separate standby Generator
• Reduced cabling costs
• Saving on building costs
EURO DIESEL Template
19
COST SAVINGS
LOW OPEX
• No A/C, hence reduced utility bills
• Continuous power factor correction, hence reduced electricity bills
• Eliminate the need to replace S-UPS batteries every 3-5 years
• Reduced maintenance
DRUPS = low maintenance, mainly bearings greasing
First overhaul after 10 years of operations only
EURO DIESEL Template
20
COST SAVINGS - TCO
EURO DIESEL Template
21
HIGH RELIABILITY
SEE MTBF CALCULATIONS
• For a single unit:
• For a N+1 installation:
EURO DIESEL Template
22
OTHER BENEFITS
USING EURO-DIESEL DRUPS
• SUSTAINABILITY (GREEN BUILDING CERTIFICATION)
• INCREASED PUE
• GUARANTEED DIESEL ENGINE START
• PROTECT BOTH IT AND MECHANICAL LOADS
• AVAILABILITY IN THE REGION AND IN THE COUNTRY
EURO DIESEL Template
23
4. DRUPS CONFIGURATIONS
24
DRUPS CONFIGURATIONS
NO-BREAK KS® - SINGLE SYSTEM
EURO DIESEL Template
25
DRUPS CONFIGURATIONS
NO-BREAK KS® - DUAL OUTPUT
EURO DIESEL Template
26
DRUPS CONFIGURATIONS
NO-BREAK KS® - LV PARALLEL
EURO DIESEL Template
27
DRUPS CONFIGURATIONS
NO-BREAK KS® - MV PARALLEL
EURO DIESEL Template
28
DRUPS CONFIGURATIONS
NO-BREAK KS® - DISTRIBUTED REDUNDANT
EURO DIESEL Template
29
DRUPS CONFIGURATIONS
NO-BREAK KS® - IP STAR BUS CONFIGURATION
EURO DIESEL Template
30
DRUPS CONFIGURATIONS
UPTIME DESIGN CRITERIA
EURO DIESEL Template
31
DRUPS CONFIGURATIONS
NO-BREAK KS® - EXAMPLE OF TIER III
EURO DIESEL Template
32
DRUPS CONFIGURATIONS
NO-BREAK KS® - EXAMPLE OF TIER IV
EURO DIESEL Template
33
DRUPS CONFIGURATIONS
NO-BREAK KS® - EXAMPLE OF TIER IV – CISCO DATA CENTER
EURO DIESEL Template
34
5. DRUPS APPLICATIONS
35
DRUPS APPLICATIONS
TYPICAL SECTORS
• Datacenters
• Hospitals
• Traffic Control Rooms
• Airports
• Industrial Plants
• High technology
TYPICAL POWER RANGES
• Power range for a single unit : 200 kVA -> 3000 kVA
• No limitation on total system rating. Ex : 26 x 2000KVA = 52 MVA
EURO DIESEL Template
36
6. LOCAL PRESENCE IN KSA
AFTER SALES SUPPORT
37
EURO-DIESEL MIDDLE EAST
EURO-DIESEL MIDDLE EAST
Main office locations:
1. Main office: 2. Qatar office:
Jebel Ali Free Zone The Gate Tower 2
Dubai, UAE Suite 706
Tel: +971 4 886 1010 Tel: +974 4020 6030
Email: sales.middleeast@euro-
diesel.com
Activities:
3. Local presence in KSA - Storage of critical spare parts and
Ahmad Khatib, Country Manager consumables
Tel: +966 53 944 5526 - Operations & Maintenance
Email: ahmad.khatib@euro- - Supervision of installation
diesel.com - Pre-sales and post-sales engineering support
EURO DIESEL Template
38
AFTER SALES - OPS SUPPORT
ALARM OR EVENT
Site Visit
Automatically
To BMS or Site Generated E-mails
Operator Remote Analysis
Loging KS Vision
Back Office
Support HQ
Call for 2nd
line support
E-mail, text message EURO-DIESEL LLC Automated Local Service
or Telephone transfer
helpdesk Technician
EURO DIESEL Template
39
AFTER SALES - OPS SUPPORT
Services
• Monitoring of quality control service sheets
to assist in identifying problems proactively
• Recording of Machine history in a Global
Service Database (worldwide)
• Full archives over its product life
• Manage preventive programs during 25
years life expectancy
• Follow up each individual machine
• Inform the customer in advance
• Analyze local situation
EURO DIESEL Template
40
7. EURO-DIESEL EFERENCES IN THE
MIDDLE-EAST
41
INSTALLED BASE ACROSS CONTINENTS ˃ 1.600.000KVA
103.409 KVA in North America 24.880 KVA in Russia
668.035 KVA in Europe
1000+
419.200 KVA in
Asia Pacific
141.100 KVA
in the Middle
East
119.200 KVA in Africa
146.160 KVA in Latin America
RECENT REFERENCES IN THE MIDDLE EAST
KSA - JEDDAH KSA - RIYADH KSA - JUBAIL
• JEDDAH MUNICIPALITY • IMAM UNIVERSITY • POLISILICON PLAN
DATA CENTER DATA CENTER
QATAR
• MEEZA MV2 DATA
CENTER
KSA - RIYADH UAE
• MOFA • MAKTOUM INTL
DATA CENTER AIRPORT
UAE
• ETISALAT KHALIFA ‘A’
DATA CENTER
KSA - JEDDAH KSA - RIYADH OMAN
• KING ABDULAZIZ INT’L • SIMAH • TRA DATA CENTER
AIRPORT DATA CENTER
EURO DIESEL Template
43
KSA – KING ABDULAZIZ INT’L AIRPORT
KEY FACTS
• International Airport in Jeddah
• DRUPS protecting the 2 main DATA
CENTERS on the airport
• 12 x DRUPS - 2000kVA – 400V –
60Hz
• 50°C environment
• Mechanical + IT loads
EURO-DIESEL SCOPE
• DRUPS Supply, design & supply of ventilation
systems
• On-site installation assistance, commissioning,
training
EURO DIESEL Template
44
KSA – JEDDAH MUNICIPALITY
KEY FACTS
• Tier 3 Data Center
• JM Headquarter Data Center
• 2 x DRUPS - 500kVA – 415V – 60Hz
• 50°C environment
• Containerized solution
EURO-DIESEL SCOPE
• DRUPS + ventilation systems + containerization
• Supply, on-site assistance, commissioning
• Operations & maintenance
EURO DIESEL Template
45
KSA – IMAM UNIVERSITY
KEY FACTS
• Tier 2 Data Center
• University Data Center
• 1 x DRUPS - 500kVA – 415V – 60Hz
• 50°C environment
• Containerized solution
EURO-DIESEL SCOPE
• DRUPS + ventilation systems + containerization
• Supply, on-site assistance, commissioning
• Operations & maintenance
EURO DIESEL Template
46
KSA – SIMAH DATA CENTER
KEY FACTS
• Tier 4 Data Center
• Banking institution
• 2 x DRUPS - 800kVA – 380V – 60Hz
• 50°C environment
• Containerized solution
EURO-DIESEL SCOPE
• DRUPS + ventilation systems + containerization
• Supply, on-site assistance, commissioning
• Operations & maintenance
EURO DIESEL Template
47
KSA – MOFA DATA CENTER
KEY FACTS
• Tier 3 Data Center
• 2 x DRUPS - 1250kVA – 380V – 60Hz
• 50°C environment
• Containerized solution
EURO-DIESEL SCOPE
• DRUPS + ventilation system + containerization
• Supply, on-site assistance, commissioning
• Operations & maintenance
EURO DIESEL Template
48
KSA – JUBAIL POLISILICON PLANT
KEY FACTS
• Polisilicon Factory
• 2 x DRUPS - 3000kVA – 400V – 60Hz
• 50°C environment
• Mechanical + IT loads
• Dual output solution:
• 1500kVA Critical Load
• 1500kVA Non-Critical Load
EURO-DIESEL SCOPE
• DRUPS Supply
• on-site assistance, commissioning
EURO DIESEL Template
49
UAE ABU DHABI – ETISALAT
KEY FACTS
• Tier 3 Data Center
• Telecom company
• 16 x DRUPS - 2500kVA
– 400V – 50Hz
• 2 Phase (4 + 12)
• 50°C environment
ED’S SCOPE
• Supply & commissioning
• Supervision of installation
• Maintenance
EURO DIESEL Template
50
UAE – MAKTOUM INT’L AIRPORT
KEY FACTS
• Protection of Airfield
Lighting Systems
• 2 x DRUPS –
1000/2000kVA –
400V – 50Hz
• Phase 1 of 5
• 50°C environment
ED’S SCOPE
• Supply, commissioning, training,
maintenance assistance
EURO DIESEL Template
51
OMAN – TELECOM REGULATORY AUTHORITY
ED’S SCOPE
• DRUPS + ventilation systems
• Supply, on-site assistance,
commissioning
• Long-Term Operations &
maintenance
KEY FACTS
• Tier 2 Data Center
• TRA Head Quarter Data Center
• 1 x DRUPS - 1900kVA – 415V –
50Hz
• 50°C environment
EURO DIESEL Template
52
QATAR – MEEZA MV2
KEY FACTS
• Tier 3 Data Center
• Co-location & IT Services
• 10,000 m2 D.C. space
• 10 x DRUPS - 1600kVA – 415V
– 50Hz
• 50°C environment
• Continuous power
ED’S SCOPE
• DRUPS + ventilation systems
• Supply, on-site assistance, commissioning
• Long-term contract for operations & maintenance on
site
EURO DIESEL Template
53
8. SPECIAL REFERENCES
54
Medicare References
800 kVA | LFKK Hospital, Linz, Austria 630 kVA | St. Michel Hospital, Belgium 250 kVA | AOKH, Austria
3 MVA | Hospital Bologna, Italy 630 kVA | Hospital Ambroise Pare, Marseille, France
EURO DIESEL Template
55
Multi MVA Data Centre References
17 MVA | Data Centre, France 12 MVA | Data Centre, Germany 13.2 MVA | Data Centre, S. Africa
12 MVA | Data Centre, UK 52 MVA | Global SwitchData Centre, Canary Wharf, UK
EURO DIESEL Template
56
IT Centre References
6 MVA | ECMWF, Reading, UK
12.4MV | Nankang Software Park, Taiwan 12 MVA | Citigroup, London, UK
EURO DIESEL Template
57
Critical Process Industry References
9.8 MVA | ATMEL, France 15 MVA | Texas Instruments, The Philippines
30.7 MVA | TFT/LCD FAB, Taiwan
10.2 MVA | Semiconductor FAB GSMC, China
EURO DIESEL Template
58
Telecommunication References
3.2 MVA | Swisscom, Olten, Switzerland 250 kVA | Telecom Italia, Roma, Italy
4.5 MVA | Fucino National Space Center, 250 kVA | British Telecom
Aquila, Italy Portsmouth , UK
EURO DIESEL Template
59
Aviation & Traffic Control References
2.3MV | Liège Airport, Belgium 3 MVA | New Bangkok Airport, Thailand
7 MVA | Dubai International Airport, UAE 3.5 MVA | Airport Madrid Barajas, Spain
EURO DIESEL Template
60
Ascenty 20MVA Data Center – Sao Paulo - Brasil
https://youtu.be/VXqt8QynTSY
EURO DIESEL Template
61
GLOBAL REFERENCES
EURO DIESEL Template
62