FIXTURE COMPONENTS
004 MS SA Implant - Narrow Ridge 008 MS Implant - Provisional
006 MS SA Implant - Denture 0 1 0 MS KIT
MS SA Implant - Narrow Ridge MS SA Implant - Narrow Ridge Components
Impression Coping - Narrow Ridge
7 Used to take fine impressions
G/H
One body implant ideal for narrow spaces such as the mandibular anterior region MSPIC
Superior SA treated surface for ideal bone to implant contact, quicker
osseointegration.
Integrated abutment head shape and size is optimized for trouble free restoration.
Recommended final torque: 30Ncm or less
L
Temporary Cap
Used for fabricating a temporary prosthesis
D
MSPTC
004 8.5 10 11.5 13 005
D Ø 2.5 G/H L
MS SYSTEM
MS SYSTEM
Lab Analog - Narrow Ridge
MS Implant narrow ridge lab analog for dental laboratory
2.5 MSN2508S25 MSN2510S25 MSN2511S25 MSN2513S25
4.0 MSN2508S40 MSN2510S40 MSN2511S40 MSN2513S40
MSPLA
D Ø 3.0 G/H L 8.5 10 11.5 13
2.5 MSN3008S25 MSN3010S25 MSN3011S25 MSN3013S25
4.0 MSN3008S40 MSN3010S40 MSN3011S40 MSN3013S40
MS SA Implant - Denture MS SA Implant - Denture Components
O-ring Retainer Cap Set
Ball abutment components
Packing unit : retainer cap + o-ring
G/H
One body implant ideal for edentulous patients for securing removal dentures
RCS01
Superior SA treated surface for ideal bone to implant contact, quicker
osseointegration
Integrated ball abutment is optimized for trouble free denture connection
Recommended final torque: 30Ncm or less L
O-ring Set
Packing unit : 5ea
D
OAON01S
006 D Ø 2.5 G/H L 8.5 10 11.5 13 007
MS SYSTEM
MS SYSTEM
O-ring Lab Analog
MS Implant denture lab analog for dental laboratory
2.0 MSD2508S20 MSD2510S20 MSD2511S20 MSD2513S20
4.0 MSD2508S40 MSD2510S40 MSD2511S40 MSD2513S40
OAL
D Ø 3.0 G/H L 8.5 10 11.5 13
2.0 MSD3008S20 MSD3010S20 MSD3011S20 MSD3013S20
4.0 MSD3008S40 MSD3010S40 MSD3011S40 MSD3013S40
MS Implant - Provisional MS Implant - Provisional Components
Provisional Cap
4.0 Used for fabricating temporary prosthetics (titanium)
4.0
One body implant ideal for temporary placement
MSTPC
Neck is designed for strength and path maintenance
Components conveniently fabricates temporary prosthetics
Recommended final torque: 30Ncm or less
Lab Analog
MS Implant provisional lab analog for dental laboratory
MSTLA
008 D Ø 1.8 L 10 13 15 009
MS SYSTEM
MS SYSTEM
MST18104 MST18134 MST18154
D Ø 2.5 L 10 13 15
MST25104 MST25134 MST25154
MS KIT (OMSK) MS KIT Surgical Instruments
Base component
Depth Gauge
MSDG Drill for MS Implant
For use with
Ratchet Wrench
CITQW-1185A
Easy to view depth markings, calibrated to implant length
(8,10,11.5,13,15mm)
Lance Drill is recommended for only drilling cortical bone
Lance drill Twist drill
L Lance Drill D Ø 1.5
35 OSLD15
L Twist Drill D Ø 1.8 Ø 2.3 Ø 2.5 Ø 2.7 Ø 3.0
Short (33) OSMSD18S OSMSD23S OSMSD25S OSMSD27S OSMSD30S
Long (41) OSMSD18L OSMSD23L OSMSD25L OSMSD27L OSMSD30L
010 011
MS SYSTEM
MS SYSTEM
Driver for Narrow Ridge &
Provisional Type
Driver specifically for MS implant narrow ridge & provisional implants
For proper use, align the laser marked arrows with the cross section
of the implant
Short Long Short Long
Torque driver Machine driver
L Torque Driver D Ø 3.4 L Machine Driver D Ø 3.4
Short (21.5) MSPTS Short (29.4) MSPMS
Long (16.5) MSPTL Long (24.4) MSPML
MS KIT Surgical Instruments
Driver for Denture Type Machine Driver
Used by connecting to the engine when inserting MS port implant
Driver specifically for MS implant denture implants L
For proper use, align the laser marked arrows with the cross
section of the implant
Short MSLDS
Short Long Short Long
Machine driver
Long MSLDL
Torque driver
L Torque Driver D Ø 3.8 L Machine Driver D Ø 3.8
Short (13.5) MSDTS Long (21.4) MSDMS
Long (18.5) MSDTL
Locator Core Tool
Used in attaching and changing replacement males
Gauge for MS Implant
Depth gauge
Left side: Used to check the depth of the osteotomy LCCT
Depth gauge
Right side: Used to angle abutment head. For use on MS Implant
provisional only
012 Parallel pin is used to check drilling path
013
Parallel pin
MS SYSTEM
MS SYSTEM
Depth Gauge Parallel Pin
MSDG MSP
Port Torque Driver
Torque Handle Used by connecting to the wrench when inserting MS port implant
Used for initial insertion
Attach torque driver joint to hand torque the implant
L
Short Long
Short OPLTDS
Long OPLTDL
MSTH
Driver Separator
Used in case a driver is wedged with the implant during insertion
Insert the Driver Separator into the driver groove to loosen it from the implant
MSDS
015
MS SYSTEM
014
MS SYSTEM