Flow Meter
Vortex Flow Meter 20/22
Flow Meter
Level Meter
Smart Pressure Transmitter
Model AT3051Series
GP
DP
AP
Differential Pressure Transmitter/Pressure Transmitter
& GENERAL
AUTO AT3051DP/GP series is a digital differential pressure transmitter
designed for industrial pressure measurement applications.
The AT3051 can be configured to provide integrated solutions
for a broad range of pressure and flow measurement applications.
& FEATURES
Updating time of output current in 200 ms
Improved performance, increased accuracy and greater stability
Two years stability of 0.2%
0.1% accuracy
Parameter setting by keypad directly
4-20 mA output plus direct digital HART communication
Automatic zero calibration by press-button
Explosion proof and weather proof housing
Process Fluid Liquid, Gas of Vapor Display 5 Digits programmable & 0-100% Bargraph
Working
-25 to +95 °C Damping 0 - 32 seconds
Temperature
Wetted O-Ring Buna N / Viton / PTFE Temperature Effect +/-0.18% ~ +/-0.5% of span per 20 °C
Bolts & Nuts Carbon Steel / Stainless Steel 316 Vibration Effect +/-0.05% of URL per g to 200 Hz in any axis
Fill Fluid Silicone / Fluorine Oil Dimensions 102 mm ( W ) * 188 mm ( H ) * 130 mm (D)
AU TO I N S T R U M E N T / 0 1
Differential Pressure Transmitter/Pressure Transmitter
AU TO I N S T R U M E N T / 0 2
Differential Pressure Transmitter/Pressure Transmitter
9~32VDC
& DIMENSIONS
AU TO I N S T R U M E N T / 0 3
Differential Pressure Transmitter/Pressure Transmitter
AU TO I N S T R U M E N T / 0 4
Direct Mount Pressure Transmitter
& GENERAL
AUTO AT3051TG/TA series is a digital pressure transmitter
designed for industrial pressure measurement applications.
The AT3051TG(TA) offer configurations for gauge pressure, absolute
pressure and vacuum including integrated solutions for industrial
applications.
& FEATURES
Updating time of output current in 90 ms
Improved performance, increased accuracy and greater stability
Two years stability of 0.15%
0.1% accuracy
Parameter setting by keypad directly
4-20 mA output plus direct digital HART communication
Automatic zero calibration by press-button
Explosion proof and weather proof housing
& DIMENSIONS
AU TO I N S T R U M E N T / 0 5
Direct Mount Pressure Transmitter
AU TO I N S T R U M E N T / 0 6
Diaphragm Level Transmitter
& GENERAL
AT3051LT series is a digital differential pressure transmitter designed
for industrial level measurement applications.
It can be configured to provide intergrated solutions for a broad range
of pressure and flow measurement applications.
& FEATURES
Updating time of output current in 200 ms
Improved performance, increased accuracy and greater stability
Two years stability of 0.15%
0.1% accuracy
Parameter setting by keypad directly
4-20 mA output plus direct digital HART communication
Automatic zero calibration by push-button
Explosion proof and weather proof housing
Diaphragm : Stainless Steel 316L / Hastelloy Zero Calibration Automatic calibration by push-button
B / Hastelloy C / Monel / Tantalum
Cable Entry 1/2" NPT(Female) / M20 Conduit Threads
AU TO I N S T R U M E N T / 0 7
Diaphragm Level Transmitter
AU TO I N S T R U M E N T / 0 8
Diaphragm Level Transmitter
9~32VDC
& DIMENSIONS
AU TO I N S T R U M E N T / 0 9
Diaphragm Level Transmitter
AU TO I N S T R U M E N T / 1 0
Diaphragm Level Transmitter
& FEATURES
The maximum temperature comes up to 280 °C
Multiple connection modes - Flange style / Tri-Clamp style
Multiple diaphragms/alternative connection material
It can be used for fill fluid for food industr y
Extreme hot and cold temperature
Stainless Steel with PPC coating capillar y
Tri-Clamp or union screw connection for food industr y
Oil-free treatment & water-free treatment
Fast and dynamic response
Improved performance, increased accuracy and great stability
AU TO I N S T R U M E N T / 1 1
Diaphragm Level Transmitter
Direct-Mount Diaphragm Min. Range Max. Range Min. Range Max. Range Max. Static Pressure
Pressure 0 - 10 kPa 0 - 100 MPa 0 - 1019.7 mmH20 0 - 10197 MH2O
Transmitter 0 - 100 mbar 0 - 1000 bar 0 - 40.15 InH2O 0 - 401463 InH2O 100 MPa
RD Series 0 - 1.45 psi 0 - 14504 psi 0 - 0.1 Kg/cm2 0 - 1020 kg/cm2
Remote Diaphragm Seal Min. Range Max. Range Min. Range Max. Range Max. Static Pressure
Pressure 0 - 6.0 kPa 0 - 8.0 MPa 0 - 611.82 mmH2O 0 - 815.76 MH2O
Transmitter 0 - 60 mbar 0 - 80 bar 0 - 24.088 InH2O 0 - 32117 InH2O 8.0 MPa
RD1 Series 0 - 0.87 psi 0 - 1160.3 psi 0 - 0.061 Kg/cm2 0 - 81.578 Kg/cm2
Differential Pressure 0 - 6.0 kPa 0 - 8.0 MPa 0 - 611.82 mmH2O 0 - 815.76 MH2O
Transmitter 0 - 60 mbar 0 - 80 bar 0 - 24.088 InH2O 0 - 32117 InH2O 8.0 MPa
RD1 / RD2 Series 0 - 0.87 psi 0 - 1160.3 psi 0 - 0.061 Kg/cm2 0 - 81.578 Kg/cm2
0 - 6.0 kPa 0 - 8.0 MPa 0 - 611.82 mmH2O 0 - 815.76 MH2O
Level Transmitter
0 - 60 mbar 0 - 80 bar 0 - 24.088 InH2O 0 - 32117 InH2O 8.0 MPa
RD1 Series
0 - 0.87 psi 0 - 1160.3 psi 0 - 0.061 Kg/cm2 0 - 81.578 Kg/cm2
AU TO I N S T R U M E N T / 1 2
Diaphragm Level Transmitter
& DIMENSIONS
AU TO I N S T R U M E N T / 1 3
Diaphragm Level Transmitter
Process A 2''
Connection C DN50
Flange Material 1 Stainless steel
Fill Fluid A Silicone Oil
(High pressure side) C Fluorine oil
0 0m
1 1m
2 2m
Capillary Length
3 4m
4 6m
5 8m
n No Capillary
Capillary
protective sleeve A Capillary with PVC sleeve
B Capillary without PVC sleeve
AU TO I N S T R U M E N T / 1 4
Diaphragm Level Transmitter
Capillary Length 3 4m
4 6m
5 8m
6 11m
n No Capillary
Capillary protective sleeve A Capillary with PVC sleeve
B Capillary without PVC sleeve
AU TO I N S T R U M E N T / 1 5
Diaphragm Level Transmitter
AU TO I N S T R U M E N T / 1 6
SP/2088 pressure Transmitter
Accuracy 0.2%FS,0.5%FS
Protection IP65
AU TO I N S T R U M E N T / 1 7
SP/2088 pressure Transmitter
& DIMENSIONS
SP Pressure Transmitter
R G 1/2″
Process Connection M NPT 1/2″
Y Customize
IF fluoro rubber(standard)
Sealing Material
IH fluoro rubber applied to Sensors(Over 10MPa)
D No Explosion-proof Required
Explosion-proof Requirements
E Explosion-proof type
2 0.20%
Accuracy
5 0.50%
AU TO I N S T R U M E N T / 1 8
Metal Capacitive Pressure sensor
Pressure Sensor
& TECHNICAL PARAMETER
Code Range
2E 0-0.125-1.5kPa
3E 0-1.3-7.5kPa
4E 0-6.2-37.4kPa
5E 0-31-186.8kPa
6E 0-117-690kPa
7E 0-345-2068kPa
8E 0-1170-6890kPa
9E 0-3480-20680kPa
0E 0-6890-41370kPa
& PERFORMANCE
Item Parameters
Accuracy ±0 . 1 %
Stability ±0 . 2% ( 12 months)
zero error: ±0 . 25 %/ 55 ℃
Temp affect
range error: ±0. 5 %/ 55 ℃
& RANGE
2 0~0.125~1.5 ● ●
3 0~1.3~7.5 ● ●
4 0~6.2~37.4 ● ● ● ●
5 0~31~186.8 ● ● ● ●
6 0~117~390 ● ● ● ●
7 0~345~2068 ● ● ● ●
8 0~1170~6890 ● ● ●
9 0~3480~20680 ●
AU TO I N S T R U M E N T / 1 9
Vortex Flow Meter
AU TO I N S T R U M E N T / 2 0
Vortex Flow Meter
P(MPa) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.8 2.0
T(℃) 120.23 133.54 143.62 151.84 158.84 164.96 170.41 175.36 179.88 187.96 195.04 201.37 207.11 212.37
ρ(kg/h) 1.129 1.651 2.163 2.669 3.17 3.667 4.162 4.655 5.147 6.127 7.106 8.085 9.065 10.05
DN20 7 10 12 14 18 20 24 28 30 36 42 48 54 60
Qmax kg
Qmin 10 100 120 140 180 200 240 280 300 360 420 480 540 600
DN25 9 13 16 20 25 30 32 37 40 48 56 64 72 80
Qmax kg
Qmin 90 130 160 200 250 300 320 370 400 480 560 640 720 800
AU TO I N S T R U M E N T / 2 1
Vortex Flow Meter
LUGB -□ -□ -□ -□ -□ -□ -□ -□ -□ -□ -□ Explanation
Nominal DN15-300(Pipeline)
diameter diameter
(In mm) DN200-1500(Plug-in)
FL Flange connection
Pipeline JZ Flange clamp
Connection Z Special rules
J Simple Formula
Insert
Q Ball type
Pipe 10 1.0%R
line 15 1.5%R
Accuracy 20 2.0%R
Insert 25 2.5%R
Z Special accuracy standards
T(S)P(S)At normal
S
temperature and pressure
Temperature and pressure
T(Z)P(Z)Twin extreme
Z
pressure
N No communication interface
Communication protocol H HART protocol
M MODBUS protocol
1 No output
Output 2 Two-wire 4-20mA output
3 Pulse output
D DC12V
Dual 12V power supply and
DB
batter y
Power supply
DD DC24V
Batter y 3.6V power supply,
B
no signal output uses only
AU TO I N S T R U M E N T / 2 2
WFD Electromagnetic Flow Meter
& APPLICATION
1. Drinking water supply, water supply, reser voir and pumping station etc.
2. Chemical acid, lye, conductive solution, cooling fluid, additives etc.
3. Drink water, beer, wine, alcohol, milk, yogurt, fruit juice, syrup, blood etc.
4. Refrigeration / air conditioning and refrigeration thermal measurement, or heat energy.
5. Sewage, industrial sewage discharge, sewage etc.
6.Control of metal industrial pump,cooling water and the flow of water.
7. The textile industr y of water, pigments, chemicals, bleaching chemicals etc.
AU TO I N S T R U M E N T / 2 3
WFD Electromagnetic Flow Meter
FLOW RATE
Diameter
inch Min flow m3/h Normal flow rate m3/h Max flow m3/h
(mm)
15 1/2’’ 0.06 0.19 3.18 6.36
AU TO I N S T R U M E N T / 2 4
WFD Electromagnetic Flow Meter
MODEL SELECTION
M Ss316
T Titanium
Electrode
D Tantalum
material
H Hastelloy Alloy C
P Plstinum-Iridium
0 No output
Signal output
1 4-20mA/Pulse
X Rubber
P Propylene Oxide
Liner material
F PTFE
A PFA
0 110-240VAC
Power supply 1 24VDC(20-36VDC)
2 Batter y power supply
0 NO communication
A15 ANSI150#Flange
AXX
connection A30 ANSI300#Flange.....
AU TO I N S T R U M E N T / 2 5
TUF-2000S Wall-Mounted Ultrasonic Flow Meter
relay output
Data Isolated RS485 serial interface can be upgraded to the meter via a PC
interface computer support protocols such as MODBUS
tube Steel, stainless steel, cast iron, cement pipe, aluminum, copper, PVC, FRP etc.
material All quality of pipeline, the lining is allowed
Within the
Pipeline tube 32-100mm,50-700mm.300-6000mm
situation diameter
Straight Sensors installed point best meet: upstream 10 D, 5 D, downstream from
pipe pump discharge 30 D for pipe diameter (D)
section
Type Water, sea water, industrial sewage, various oil, acid alkali, alcohol, beer can
support such as ultrasonic single homogeneous liquid
Power
supply DC8~36V or AC85~264V
AU TO I N S T R U M E N T / 2 6
TUF-2000S Wall-Mounted Ultrasonic Flow Meter
AU TO I N S T R U M E N T / 2 7
TUF-2000H Handheld Ultrasonic Flow Meter
Linearity 0.5%
Repeatability 0.2%
Totalizer 7-digit totals for net, positive and negative flow respectively
Data Logger Built-in data logger can store over 2000 lines of data
AU TO I N S T R U M E N T / 2 8
TUF-2000 Portable UltrasonicFlow Meter
Power 8 built-in Ni-MH batteries 1.2V(for over 20 hours of operation) Could operate 8
Supply hours by connecting 4-20mA signal output. 90V - 260V AC adapter
Power 1.5W
Consumption
AU TO I N S T R U M E N T / 2 9
Oval Gear Flow Meter
& DESCRIPTION
Oval gear flow meter is pointer and Lcd display.It is a kind of light volume flow meter of which the print
wheel has cumulative count and zero.This flow meter is widely used in various industrial areas to control
the liquid flow.
It is application to all types of liquid measuring,such as crude oil,diesel,gasoline and so on.
with great range and high precision.convenient use and maintenance.Different materials selected can meet
the petroleum,chemical,pharmaceutical,food,metallurgy,electricity,transportation and other fields of liquid
flow measurement.
Fluid enters inlet port and then passes through the metering chamber,Inside the chamber,fluid forces the
internal gears to rotate before exiting through the outlet port.Each rotation of the gears displace a specific
volume of fluid.As the gears rotate,a magnet on each end of the gear passes a reed switch in the top
mounted register ’s circuit board.
1.Application:high viscosity liquid,as heavy oil,fuel oil,diesel oil,ect.
2.Accuracy : class 0.5,class0.2
3.Measured media temp :-10Deg C~+200Deg C
4.Output signal:4-20mA,Pulse output,RS485
5.LCD Display.pointer display.
5.Viscosity :0.3 to 2000mPa.S
6.Body material:cast steel , cast iron ,stainless steel
7.Working pressure:PN1.6 to 6.4
AU TO I N S T R U M E N T / 3 0
Oval Gear Flow Meter
Model Instruction
LC / / / / / /
10 10mm
15 15mm
20 20mm
25 25mm
40 40mm
Diameter 50 50mm
80 80mm
100 100mm
150 150mm
200 200mm
1 Standard Type
Instrument Type 2 High Temperature Type
3 High Viscosity Type
1 Cast Iron
Instrument Material 2 Cast Steel
3 Stainless Steel
1.6 (1.6Mpa)
2.5 (2.5MPa)
Pressure type
4.0 (4.0MPa)
6.4 (6.4MPa)
1 No signal Output
Signal Output Type 2 Pulse Output
3 4-20mA Output
1 Mechanical pointer display
Instrument head 2 Resetable head pointer display
3 LCD display
LC 15/ 1 1 1 1 1 Selection Example
AU TO I N S T R U M E N T / 3 1
Radar Level Meter
AU TO I N S T R U M E N T / 3 2
Radar Level Meter
AU TO I N S T R U M E N T / 3 3
Radar Level Meter
AU TO I N S T R U M E N T / 3 4
Radar Level Meter
License
P Standard (Non-explosion-proof )
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Gb)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
A Flange DN50 / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
Y Special Custom
Antenna Type / Material
A Horn Antenna Φ46mm / Stainless Steel 316L
B Horn Antenna Φ76mm / Stainless Steel 316L
C Horn Antenna Φ96mm / Stainless Steel 316L
Y Special Custom
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Plastic/ IP65
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A Belt
X Without
AU TO I N S T R U M E N T / 3 5
Radar Level Meter
AU TO I N S T R U M E N T / 3 6
Radar Level Meter
License
P Standard (non-explosion-proof )
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, flameproof [Exd (ia) IIC T6 Gb]
Process Connection/ Material
G G1½″ A Thread
A DN50 PN16 C flange type / stainless steel 316L
B DN80 PN16 C flange type / stainless steel 316L
C DN100 PN16 C flange type / stainless steel 316L
D DN150 PN16 C flange type / stainless steel 316L
E DN200 PN16 C flange type / stainless steel 316L
F DN250 PN16 C flange type / stainless steel 316L
Y Special Custom
Antenna Type / Material
1 No horn antenna, guided wave pipe installation / Stainless steel
2 76mm horn antenna / stainless steel
3 96mm horn antenna /stainless steel
4 146mm horn antenna / stainless steel
5 196mm horn antenna / stainless steel
6 242mm horn antenna / stainless steel
Seal / Process Temperature
1 Ordinar y type (-40 ~ 150) ℃
2 High temperature (-40 ~ 250) ℃
Antenna Extension
A 100 mm
B 200 mm
C 300 mm
Y Special Custom
Shell / Protection Class
L Aluminum /IP67
Q Plastics / IP65
Cable Line
M M 20x1.5
N ½″ NPT
Field Display
A Belt
X Without
The Programmer
A Belt
X Without
AU TO I N S T R U M E N T / 3 7
Ultrasonic Level Meter
& DESCRIPTION
Application field:Water and sewage treatment: pump house, collecting well, biochemical reaction tank,
sedimentation tank, electric power, mine: mortar pool, coal slurr y tank, water treatment, etc.
Level Range 5M, 10M, 15M, 20M,30M, 50M 5M, 10M, 15M, 20M, 30M, 50M, 70M
220VAC+15% 50Hz
24VDC 120mA
Power Supply 24VDC 120mA
12VDC
12VDC
Environment Meter : -20~+60°C Meter -20~+60°C
Temperature Sensor : -20~+80°C Sensor -20~+80°C
AU TO I N S T R U M E N T / 3 8
Ultrasonic Level Meter
AU TO I N S T R U M E N T / 3 9
ATWLM Water Level Meter
& APPLICATION
water conser vancy project,
hydrology, geography, environmental protection
other areas of industr y and agriculture fields
other liquid level measurement
AU TO I N S T R U M E N T / 4 0
Level Switch
Level Switch
Tuning fork level switch
& DESCRIPTION
tuning fork level switch is an economical limit control switch
designed for level measurement. The overall structure of the
product suitable for containers, storage tanks, tanks and liquid
level measurement with foam, air bubbles, viscous liquid and
vibration interference.
Model Name
AFTL Tuning Fork Switch
Code Power Supply
1 220V AC
2 24VDC
Code Temperature Type
H High Temperature Type
S Common Type
Code Fork Sort
A Standard Type
C Shock Rod Type
S Compact Type
Code Fork Type and Insertion Depth Range
G1 Small Fork 45mm~3000mm
G2 Standard Fork 100mm~3000mm
Code Process Connection
N1 1″ NPT thread
G1 G1″ thread
DN25 DN25
DN40 DN40
DN50 DN50
TC1 1″ Clamp
TC2 2″ Clamp
Customers Supply Insertion Length