0% found this document useful (0 votes)
21 views22 pages

монитор

The document provides instructions for operating the Starting Window and Meter Window, including how to display gauge values, alarm and fault information, and access service and setting menus. It details key combinations for various functions, such as displaying the IO Monitor Menu and adjusting settings. Additionally, it includes an Easter Egg feature for accessing advanced settings like language setup and auto-lubrication mode.

Uploaded by

mirbek mairykov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views22 pages

монитор

The document provides instructions for operating the Starting Window and Meter Window, including how to display gauge values, alarm and fault information, and access service and setting menus. It details key combinations for various functions, such as displaying the IO Monitor Menu and adjusting settings. Additionally, it includes an Easter Egg feature for accessing advanced settings like language setup and auto-lubrication mode.

Uploaded by

mirbek mairykov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 22

Last updated: Oct 26, 2006

The Starting Window

Turning the key switch on

The Starting Window


When the starting check is completed,
the meter window is automatically displayed after:
four seconds if the check is successfully completed.
eight seconds if the check is failed.
However, you can display the meter window immediately
by pressing the [○] check key.

Note: ①
The meter window is displayed if you press the [X] key
in the starting window.


The following window is automatically displayed.
The Meter Window ①

Note:

Displaying the gauge values


Press the [?] key while holding the [*] key to display
the gauge values.
again to hide the values.
The display setting is maintained after the key switch is
turned off.

*(attention) meter screen is a thing of EX8000-1.


Last updated: Oct 26, 2006
The Meter Window

1. Displaying Alarm and Fault Information

The Meter Window *(attention) meter screen is a thing of EX8000-1.


[←] is displayed when the alarm is incurred. It is not
displayed under the normal circumstances.
[→] is displayed when the fault is incurred. It is not
displayed under the normal circumstances.

Note:

Displaying the gauge values


Press the [?] key while holding the [*] key to display
the gauge values.
again to hide the values.
The display setting is maintained after the key switch is
turned off.

① ②

Alarm List ① ②

③ ④

The Alarm Detail Window The Circuit Diagram Window

③ ④ ③

The Alarm List


The Alarm List

The Meter Fault List


Window

③ ④ The Meter Window

The Fault Detail Window The Circuit Diagram Window

③ ④ ③

2. Easter Egg (Pressing Two Keys)

The Meter Window


The Easter Egg from the Keypad
1. Displaying the IO Monitor Menu Window (the Shortcut Key)
Press the [↑] key while holding the [*] key to display
the IO monitor menu window.
2. Checking the Warning
Press the [←] key while holding the [*] key to display
the alarm list window. All alarms are displayed in
this window.
3. Checking the Failure
Press the [←] key while holding the [*] key to display
the fault list window. All faults are displayed in
this window.
4. Displaying the Gauge Values
Press the [?] key while holding the [*] key to display
the gauge values. Press the keys again to hide the values.
*(attention) meter screen is a thing of EX8000-1. The display setting is maintained after the key switch is
turned off.
Last updated: Oct 26, 2006
Service Menu

In the Service Menu window, you can access:


Automatic Snapshot (replays the failure monitor data)
Monitor and Manual Snapsh(monitors the machine information)
Maintenance History (records maintenance history)
Life (displays the machine information)
Machine Information (displays the version of the network controller)
Various Setup (Menu) (displays the specified setup menu)

1. Displaying the Service Menu

The Meter Window *(attention) meter screen is a thing of EX8000-1.


Press the [○] key on the meter window.

① ②

④ ⑤

2. Functions in the Service Menu

The Service Menu Window

③ ④
Service menu Service menu

Automatic Snapshot

③ ④
Replaying the Automatic Snapshot Item

Monitor and Manual Snapshot

③ ④
Service menu
Selecting an item in the Monitor and Manual Snapshot Window Monitor and
Manual Snapshot

Monitor and
Manual
Snapshot

③ ④
Monitor and Manual Snapshot: Monitoring Data


Monitor and Manual Snapshot: Recording Data


Monitor and Manual Snapshot: Finished Recording Data


Service Menu Monitor and Manual Snapshot: Creating the Recording Data
You can replay the latest
recording data

Monitor and Finished


Manual Recording Data
Snapshot

Monitor and Manual Snapshot: Selecting the Replaying Data


Monitor and Manual Snapshot: Replaying the Recording Data

Maintenance History: Maintenance History List


③ ④ Service Menu
Maintenance History: Maintenance Implementation Record
Service Menu

Service Menu

③ ④
Canceling the record

Maintenance History: Implementation Record

③ ④

Life


Service Menu
Service
Menu Machine Information


Service Menu
Last updated: Oct 26, 2006
Setting Menu: Various Setup

In the Setting Menu window, you can access:


Maintenance Setup (changes the maintenance history data)
Snapshot Setup (Initializes the manual snapshot:data)
Time Adjust (adjusts time)
Setting Put-out Lights Del (sets the delay time of the light off following the key switch off)

1. Displaying the Setting Menu: Various Setup

The Meter Window *(attention) meter screen is a thing of EX8000-1.


Press the [○] key on the Meter window.

① ②

④ ⑤

The Service Menu Window


Press the [↓] key five times on the Service Menu window.
Select Various Setup and press the [○] key.

2. Setting Menu: Various Setup

Setting Menu
0 ③ ④
Setting Maintenance Setup
Menu You can change:
Interval
Remaining Time
Alarm

Setting
Menu

③ ⑤
Maintenance Setup: Submenu

③ ④

Snapshot Setup

③ ④ Setting Menu

Initializing the manual snapshot data



Setting Menu

Setting Time Adjust


Menu If DLU is unavailable or GMT is incorrect, input
the local standard time.

③ ④
Setting Menu
Time Adjust: Time Differences

Setting Put-out Lights Delay Time

③ Setting Menu
Last updated: Oct 26, 2006
Setting Menu 2: Easter Egg

In the Setting Menu 2 window (Easter egg ), you can access:


Language setup (changes among English, Spanish, and Japanese)
Autolube (sets the auto-lubrication check mode)
IO Monitor (displays the I/O status of the MC/IDUV/DLU/ELU/HMU controllers)
Setting Serviceman mode setup (sets the meter window and the time for the alarm and fault massage)
Color Adjust (adjusts the LCD: RGB and position)

1. Displaying the Setting Menu 2 Window (Easter Egg)

The Meter Window *(attention) meter screen is a thing of EX8000-1.


] Press the [○] key to display the Service Menu window.

② ③


⑦ ⑧

The Service Menu Window


Press the [↓] key five times on the Service Menu window.
Select Various Setup and press the [○] key.
The Various Setup window is open.

Setting Menu
On the Setting Menu window:
Hold the [←] key for more than one second
Hold the [→] key for more than one second
Hold the [*] key for more than one second
to display the Setting Menu 2 window (Easter Egg).

0
Setting
2. The Setting Menu 2 Window (Easter Egg) Menu

Setting Menu 2: Easter Egg


Use the [↑] and [↓] keys and press the [○] key to select
an item.

Setting
Menu

⑥ ⑦

Language setup

⑥ ⑦

If the window on the left is displayed, turn


off the key switch, wait until the screen is
blackened out, and then turn on the key
switch again.
The screen on the left is maintained if
you turn off the key switch and turn on
the key switch again before the screen is
blackened out.
Setting Menu 2: Setting Menu 2:
Easter Egg Autolube Easter Egg

IO Monitor
If you have switched from the Meter
window, you can return to the window by
pressing the [X] key.

⑥ ⑦



Setting Menu 2: IO Monitor


Easter Egg
IO Monitor

Setting Serviceman mode setup

⑥ Setting Menu 2

Color Adjust
Setting Menu 2:
Easter Egg Refer to the additional document for information on adjusting

⑥ Setting Menu 2