0% found this document useful (0 votes)
72 views3 pages

Control Unit CED160 - ENG

The CED160 electronic control unit has: 1) One proportional function control with 2 outputs and 6 digital outputs controlled through relays. 2) It is designed for 12VDC applications like PHC electronic systems. 3) Key features include 3 analog inputs, 6 digital inputs, 1 proportional output pair, and 6 ON/OFF outputs.

Uploaded by

costelchelariu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views3 pages

Control Unit CED160 - ENG

The CED160 electronic control unit has: 1) One proportional function control with 2 outputs and 6 digital outputs controlled through relays. 2) It is designed for 12VDC applications like PHC electronic systems. 3) Key features include 3 analog inputs, 6 digital inputs, 1 proportional output pair, and 6 ON/OFF outputs.

Uploaded by

costelchelariu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CED160 electronic control unit

• 12VDC applications
• One proportional function control (1 input / 2 outputs)
• Six digital outputs control (through six relays)
• Designed for PHC electronic systems

Working conditions
General features CED160
Supply voltage from 9 to 16 V
Current consumption 50 mA (no-load current) 15A (max. supply)
Max. current output 7.5 A
Interface CAN 2.0 A - B, 125-250 Kbit/sec
EMC compatibility 150 V/m - ISO13766, ISO14982
Environmental compatibility IEC60068-2-6/27/29
Working temperature from -40 to +85°C (from -40°F to 185°F)
Protection degree IP67 with mating connector attached
Weight 0.3 Kg (0.66 lb)

Analog inputs
Number 3
Signal type from 0.5 to 4.5 V

Digital inputs
Number 6
Signal type 0/VB

Proportional outputs
Number 1 couple
Type HSD*
Signal PWM
Frequency from 50 to 300 Hz
Max. load 2A

ON/OFF outputs
Number 6
Signal type relay (HSD*)
Max. load 7.5 A

NOTE (*): HSD - High Side Driver


LSD - Low Side Driver

D1WWEE01E 33
Electronic control units
CED160 electronic control unit________________________________________________________________________
Dimensions and pin-out

D1 connector D2 connector
7 12 1 6
36.6
1.44

6 1 12 7

DTM13-12PA DTM13-12PB
Deutsch connector Deutsch connector Connector PIN-OUT
118.3 Function
4.66 Pin
102.2 D1 connector D2 connector
4.02
1 OUT_1 DI_5
2 VB- DI_6
3 CAN_H DI_1
4 CAN_L GND_P
5 OUT_5 AI_3
Ø 0.29
Ø 7.4

6 OUT_6 AI_2
133.8
5.27

7 VK+ AI_1
8 VK+ OUT_B
9 OUT_2 DI_2
58.3
2.29

10 OUT_3 DI_3
11 OUT_4 DI_4
12 OUT_1 OUT_A
D1 D2

DM1 DM2 Mating connectors


Name Type

DM1 DTM06-12SA Deutsch


DM2 DTM06-12SB Deutsch

CED160 control unit code


Code 183360008

Description CED160/PHC160F-12V/v4.00
Supply voltage 12V, 1 prop. function (2
Notes outputs - 2A), 3 ON-OFF functions (6
outputs - 5A)

34 D1WWEE01E
Electronic control units
_______________________________________________________________________
CED160 electronic control unit
System diagram
Specific circuit configuration
The CED160 control unit is available in dedicated configuration for the SDE series with direct acting solenoid control.
It is possible to configure the system with a maximum of 1 Master controller (1 proportional, 1 unloader and 6 on/off coils) and
3 Slave controllers (6 on/off coils for every controller).
For information, please contact our Sales Department.

VB+ (from 9 to 16 VDC)

CED160
Power supply circuit Outputs
F1 VK+ = 9+16V
20A power supply VK+ HSD drivers OUT_6 function 3, side B
VK+ D1.07 D1.06
(60W, 12V, 85°C) OUT_5 function 3, side A
VK+ D1.08 D1.05
OUT_4 function 2, side B
VK+ D1.11
CONSOLE OUT_3 function 2, side A
Inputs D1.10
uC OUT OUT_2 function 1, side B
D1.09
Digital OUT_1 function 1, side A
Master/Slave 0/VK+ D1.01
OUT_1 (function 1, side A)
configuration DI_1 IN D1.12
D2.03
uC HSD drivers
Master/Slave
configuration DI_2 (24W, 12V, 85°C) enable
D2.09 VK+ OUT_B (unloader valve)
Rin=10K D2.08
proportional
uC OUT OUT_A (flow rate valve)
D2.12
5V
P E 1A 1B 2A 2B 3A 3B

Analog LSD drivers


0.5÷4.5 IN
proportional,
IN GND_P feedback
uC uC D2.04
function 1, input AI_1
J1 D2.07
function 2, input AI_2 Rin=60K uC
J2 D2.06 0R1
function 3, input AI_3
J3 D2.05

Ground circuit CAN


120R D1.04 CAN_L
ground reference VB- D1.02 termination R3
120R D1.03 CAN_H
resistance
connected
VB-

CAN_HI
R1 R2
120R CAN_LO 120R

CED configuration
DI_1 DI_2 CED
CEDA
GND GND
(Master)
CEDB
VB+ GND
(Slave1)
CEDC
GND VB+
(Slave2)
CEDD
VB+ VB+
(Slave3)

D1WWEE01E 35