DATASHEET
SRB301LC/B 24V
                                Suitable for the signal processing of outputs with contact sensors
                                Suitable for the signal processing of outputs with contact sensors
                                Suitable for signal processing of outputs connected to potentials
                                (AOPDs), e.g. safety light grids/curtains
                                3 safety contacts, STOP 0
                                1 Signalling output
Data
Ordering data
Product type description            SRB301LC/B 24V
Article number (order number)       101177962
EAN (European Article Number)       4250116201686
eCl@ss number, Version 9.0          27-37-18-19
eCl@ss number, Version 11.0         27-37-18-19
ETIM number, version 7.0            EC001449
ETIM number, version 6.0            EC001449
Available until                     31.12.2022
Approval - Standards
Certificates                        cULus
                                    CCC
                                    EAC
General data
Standards                          IEC 61508
                                   IEC/EN 60204-1
                                   EN 60947-5-1
                                   EN ISO 13849-1
Climatic stress                    EN 60068-2-78
Enclosure material                 Glass-fibre reinforced thermoplastic, ventilated
Material of the contacts,          AgSn0. self-cleaning, positive drive
electrical
Gross weight                       230 g
General data - Features
Stop-Category                      0
Wire breakage detection            Yes
Start input                        Yes
Feedback circuit                   Yes
Automatic reset function           Yes
Earth connection detection         Yes
Integral System Diagnostics,       Yes
status
Number of auxiliary contacts       1
Number of LEDs                     4
Number of openers                  2
Number of safety contacts          3
Safety appraisal
Standards                          EN 60947-5-1
                                   IEC 61508
Safety appraisal - Relay outputs
Performance level, stop 0, up to   e
Category, Stop 0                   4
Diagnostic Coverage (DC) Level,      ≥ 99 %
Stop 0
PFH-Value Stop 0                     2.00 x 10⁻⁸ /h
Safety Integrity Level (SIL), Stop   3
0, suitable for applications in
Mission time                         20 Year(s)
Common Cause Failure (CCF),          65
minimum
Mechanical data
Mechanical life, minimum             10,000,000 Operations
Mounting                             Snaps onto standard DIN rail to EN 60715
Mechanical data - Connection technique
Terminal Connector                   rigid or flexible
                                     Screw terminals M20 x 1.5
Terminal designations                IEC/EN 60947-1
Cable section, minimum               0.25 mm²
Cable section, maximum               2.5 mm²
Tightening torque of Clips           0.6 Nm
Mechanical data - Dimensions
Width                                22.5 mm
Height                               100 mm
Depth                                121 mm
Ambient conditions
Degree of protection of the          IP40
enclosure
Degree of protection of the          IP54
mounting space
Degree of protection of clips or   IP20
terminals
Ambient temperature, minimum       -25 °C
Ambient temperature, maximum       +45 °C
Storage and transport              -40 °C
temperature, minimum
Storage and transport              +85 °C
temperature, maximum
Resistance to vibrations to EN     10...55 Hz, Amplitude 0.35 mm, ± 15 %
60068-2-6
Restistance to shock               30 g / 11 ms
Ambient conditions - Insulation value
Rated impulse withstand            4 kV
voltage U
            imp
Overvoltage category               III
Degree of pollution to IEC/EN      2
60664-1
Electrical data
Frequency range                    50 Hz
                                   60 Hz
Rated operating voltage            24 VAC -15% / +10%
                                   24 VDC -15%/+20%, residual ripple max. 10%
Rated AC voltage for controls,     20.4 VAC
50 Hz, minimum
Rated control voltage at AC 50     26.4 VAC
Hz, maximum
Rated AC voltage for controls,     20.4 VAC
60 Hz, minimum
Rated control voltage at AC 60     26.4 VAC
Hz, maximum
Rated AC voltage for controls at   20.4 VDC
DC minimum
Rated control voltage at DC,        28.8 VDC
maximum
Electrical power consumption        1.7 W
Electrical power consumption        1.9 VA
Contact resistance, maximum         0.1 Ω
Note (Contact resistance)           in new state
Drop-out delay in case of power     80 ms
failure, typically
Drop-out delay in case of           20 ms
emergency, typically
Pull-in delay at automatic start,   100 ms
maximum, typically
Pull-in delay at RESET, typically   20 ms
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-   230 VAC
15
Current, Utilisation category AC-   6A
15
Voltage, Utilisation category DC-   24 VDC
13
Current, Utilisation category DC-   6A
13
Switching capacity, minimum         10 VDC
Switching capacity, minimum         10 mA
Switching capacity, maximum         250 VAC
Switching capacity, maximum         8A
Electrical data - Digital inputs
Conduction resistance,              40 Ω
maximum
 
Electrical data - Digital Output
Voltage, Utilisation category DC-   24 VDC
12
Current, Utilisation category DC-   0.1 A
12
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum         24 VDC
Switching capacity, maximum         2A
Electrical data - Electromagnetic compatibility (EMC)
EMC rating                          EMC-Directive
Status indication
Indicated operating states          Position relay K2
                                    Position relay K1
                                    Internal operating voltage U
                                                                i
Other data
Note (applications)                 Safety sensor
                                    Guard system
                                    Emergency-Stop button
                                    Pull-wire emergency stop switches
                                    Safety light curtain
Notes
Note (General)                      Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a
                                    suitable circuit.
Circuit example
Note (Wiring diagram)     The wiring diagram is shown with guard doors closed and in de-energised
                          condition.
                          The control system recognises wire-breakage and earth faults in the monitoring
                          circuit.
                          Relay outputs: Suitable for 2 channel control, for increase in capacity or number
                          of contacts by means of contactors or relays with positive-guided contacts.
                          Automatic start: The automatic start is programmed by connecting the feedback
                          circuit to the terminals X1/X2. If the feedback circuit is not required, establish a
                          bridge.
                          For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22
                          Connect potential p-type outputs of safety light grids/curtains to S12/S22. The
                          devices must have the same reference potential.
                          Input level: The example shows a 2-channel control of a guard door monitoring
                          with two position switches, whereof one with positive break, external reset button
                          (R); cross-wire monitoring and feedback circuit (H2)
Pictures
Product picture (catalogue individual photo)
                                            ID: ksrb3f03
                                            | 732.6 kB | .jpg | 265.642 x 529.167 mm - 753 x 1500 px - 72
                                            dpi
                                            | 88.6 kB | .png | 74.083 x 147.461 mm - 210 x 418 px - 72 dpi
Symbol (technical standard)
                                            ID: kformm02
                                            | 191.1 kB | .jpg | 352.778 x 246.592 mm - 1000 x 699 px - 72
                                            dpi
Wiring example
                                                    ID: 1srb3l04
                                                    | 74.5 kB | .cdr |
                                                    | 101.3 kB | .jpg | 352.778 x 248.003 mm - 1000 x 703 px - 72
                                                    dpi
 Wiring example
                                                    ID: ksrb3l11
                                                    | 149.9 kB | .jpg | 352.425 x 359.833 mm - 999 x 1020 px - 72
                                                    dpi
 Wiring example
                                                    ID: ksrb3l23
                                                    | 34.1 kB | .cdr |
                                                    | 123.5 kB | .jpg | 352.778 x 285.044 mm - 1000 x 808 px - 72
                                                    dpi
Schmersal Canada Ltd., 29 Centennial Road, Unit 1, Orangeville, Ontario L9W 1R1 Canada
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data
can be found in the manual. Technical amendments and errors possible.
Generated on: 2022-02-26, 10:20 a.m.