CLTD stand for Cooling Load Temperature
Difference
The uncontrolled entry of ventilation
untreated, outdoor air directly
into the conditioned space is
known as
Which of the following Fenestration is important in
statement is TRUE? buildings as it provides visual
communication to the outside
world
Which of the following is not Ventilation and infiltration
latent heat gain source
Which of the following The sol-air temperature depends
statements are TRUE? on indoor and outdoor
temperatures
Which of the following Infiltration load is a part of the
statements are TRUE? building load
Which of the following Cooling Load Factor is used for
statements are TRUE? both radiative as well as
convective components
Which of the following Ventilation is required for
statements are TRUE? supply of oxygen for breathing
only
Which of the following Fenestration is important in
statements are TRUE? buildings as it provides visual
communication to
the outside world
Which of the following External shading of windows is
statements are TRUE? taken care of by using a shading
coefficient
Option Text 2 Option Image 2Option Text 3 Option Image 3
Cooling Load Logarithmic Cooling Load Temperature
Temperature Difference Deviation
infiltration pressurization
Heat transfer through Heat transfer due to
fenestration generally forms a fenestration depends only on
small part of the total building the properties of the
load transparent material
Occupants body Cooking foods, baking, and
boiling
The sol-air temperature The sol-air temperature
depends on outdoor depends on outdoor
temperature and incident solar temperature, incident solar
radiation radiation and surface
properties of the wall
Infiltration load is not a part Infiltration rate increases as
of the building load the pressure difference across
the building
decreases
Cooling Load Factor is used The cooling load factor
for radiative component only increases as the thermal
capacity of the walls increase
Ventilation is uncontrolled, Ventilation requirement
while infiltration is controlled depends on occupancy and
also on activity level
Heat transfer through Heat transfer due to
fenestration generally forms a fenestration depends only on
small part of the total the properties of the
building load transparent material
Internal shading of windows The shading coefficient for
is taken care of by using a the reference SS glass is 0.0
shading coefficient
Option Text 4 Option Image 4Correct Option
Cooling Load Temperature 1
Distrubution
Fenestration 2
Fenestration is undesirable 1
and hence should be
minimized
Lightening 4
The sol-air temperature 4
depends on outdoor
temperature, incident solar
radiation, surface properties
of the wall and the external
heat transfer coefficient
Infiltration rate is 1
uncontrollable
The value of cooling load 2
factor always lies between 1
and 5
Ventilation is required for 3
supply of air for breathing
only
Fenestration is undesirable 4
and hence should be
minimized
The shading coefficient for 2
the reference SS glass is 0.5