Position Indicators: Simulation Working State Indicators

This document provides information about position indicators from Cewe Secure, including their applications, features, benefits, technical specifications, and connection diagrams. The position indicators are designed for use in indicator panels and mimic panels to show the position of electrical circuit breakers, isolators, and valves. They are available in various formats and sizes, operate on low power, and comply with relevant safety and electromagnetic compatibility standards.

Uploaded by

Teguh Waluyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
172 views2 pages

Position Indicators: Simulation Working State Indicators

This document provides information about position indicators from Cewe Secure, including their applications, features, benefits, technical specifications, and connection diagrams. The position indicators are designed for use in indicator panels and mimic panels to show the position of electrical circuit breakers, isolators, and valves. They are available in various formats and sizes, operate on low power, and comply with relevant safety and electromagnetic compatibility standards.

Uploaded by

Teguh Waluyo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Position Indicators

Simulation working state indicators

Teguh Waluyo
08212 4272 464
Cewe - Secure

Our range of position indicators is designed for use in indicator


panels and mimic panels. Position indicators for electrical
circuit breakers and isolators are available with indicator discs
in 'bar', 'angle' and 'disconnector' designs.

Indicator discs for valves are available in 'amber-white' and


'red-green' formats. A moving-magnet system is used, ensuring
high precision of movement of the indicator disc while keeping
the power consumption low.

Application Feature
Ÿ Distribution panels in power plants, substations and plant Ÿ Available in AC and DC variants
rooms Ÿ 'bar', 'angle' and 'disconnector' formats for circuit breakers
Ÿ Mimic panels for electrical systems, chemical and water and isolators
industries Ÿ 'amber-white' and 'red-green' formats for valves
Ÿ Industrial plant rooms for commerce, institutions and Ÿ Screw terminals for cables up to 1.5 mm²
industry Ÿ Available in a range of sizes: 24x24, 25x25, 36x36, Ø 29 and
Ø 39 mm
Benefits Ÿ Provided with protection cover

Ÿ High accuracy and reliability through use of moving-magnet Ÿ Polycarbonate enclosure (IP 54 rated)
system Ÿ Wide operating voltage range 24-230 VDC
Ÿ Low power consumption Ÿ Suitable for panel thickness up to 12 mm
Ÿ No need for external setting of 'zero' position Ÿ Standards compliance
Ÿ Easy to fit, using sleeve and nut · Personal safety EN 61010:1
· Double isolated to category III, Table D12
· IEC 51, EN 50081-1, EN 50081-2, EN50082-1, EN50082-1,
IEC 473
Position Indicators
Technical specifications
For DC auxiliary voltage

Type PI 24 PI 25 PI 29 PI 36 PI 39
Front flange mm 24 x 24 25 x 25 ø 29 36 x 36 ø 39
Housing ø mm 21.8 21.8 21.8 21.8 21.8
Voltage V (DC) 24 - 230 24 - 230 24 - 230 24 - 230 24 - 230
Test voltage kV 3.7 3.7 3.7 3.7 3.7
Power consumption W 0.4/1.4 0.4/1.4 0.4/1.4 0.4/1.4 0.4/1.4
Weight kg (approx.) 0.1 0.1 0.12 0.15 0.15

For AC auxiliary voltage

Type PIR 24 PIR 25 PIR 29 PIR 36 PIR 39


Front flange mm 24 x 24 25 x 25 ø 29 36 x 36 ø 39
Housing ø mm 21.8 21.8 21.8 21.8 21.8
Voltage V (AC) 24 - 230 24 - 230 24 - 230 24 - 230 24 - 230
Test voltage kV 3.7 3.7 3.7 3.7 3.7
Power consumption VA 0.4/1.4 0.4/1.4 0.4/1.4 0.4/1.4 0.4/1.4
Weight kg (approx.) 0.1 0.1 0.12 0.15 0.15

Connection diagrams Connection 3 = 24-90 V DC/AC


Connection 4 = 91-230 V DC/AC

On De-energized Off On De-energized Off On De-energized Off


(~) + (~) + (~) +

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4
(~) - (~) - (~) -

-1 / -2 -3 / -4/ -5
Specifications are subject to change without prior notice

Australia Europe India, SE Asia, Africa UAE UK


sales_australia@securemeters.com sales_europe@securemeters.com sales_india@securemeters.com sales_middleeast@securemeters.com sales_uk@securemeters.com
www.securemeters.com/au www.securemeters.com/eu www.securemeters.com/in www.securemeters.com/me www.securemeters.com/uk

www.cewesecure.se