FIRE SYSTEMS
PRODUCT CATALOGUE
     We are
SENSITIVE to Fire!
We serve with our wide product range in electric and
             diesel-driven fire pumps.
    Quality, Reliable, Innovative
  Duyar Pompa, helps to choose convenient pumps and pumping systems that meet the needs with its
efficient fire pumps and wide after-sales service programs. Duyar Pompa is a long-term business partner
that provides time-saving in the selection and evaluation of pumps and pumping systems of Turkey’s
biggest industrial and public enterprises.
With its expertise in fire systems, Duyar pompa manufactures fire pumps and pumping systems that work
reliably when required, comply with the NFPA 20 ve EN 12845 standards. The manufactured fire fighting
sets are used in;
.
    Building Technologies
.
    Industrial Facilities
.
    Power Plants
.
    Fuel and Gas Industries.
Fire and Responsibility
Combustion is a chemical reaction that occurs            foam monitor, etc. are required to be installed. With
when oxygen, heat, and combustible material get          the cutting-edge technology that Duyar Pompa
together. And fire is a disaster that takes place         reached; compact design, Split Case, End-Suction,
against our will and control, causing material and       and Multi-Stage fire pumps that are produced in
moral damages. Within the scope of the regulation        accordance with NFPA 20 criteria can be used in
issued on fire protection; fire protection equipment,      new investments, package fire revisions, and retrofit
that complies with the building or plant and fire         projects.
class, such as fire cabinet, sprinkler line, hydrant,
Low Installation
and Operation
Costs
Our leading-edge technology, highly efficient pumps
ensure;
.
  Less power consumption .
.
  Smaller equipment options .
.
  Smaller cabinets.
  These factors contribute to lower equipment
costs. The fabrication parts are produced in standard
to ensure high durability and appropriate pump
installation. With fine balancing; rotating parts lead
to mechanical reliability, reliable operation, and
minimum maintenance cost.
                                                                                                            3
    Areas of Use
    Building Technologies
    Industrial Facilities
    Power Plants
    Fuel and Gas Industry
4
                                       NFPA
                                       National Fire Protection Association (NFPA) was established by a group of
                                       insurers in the USA in 1896 to minimize the effects of fire and other risks. NFPA
                                       20 is the most wide-spread and detailed resource used worldwide in fire-fighting
                                       systems that defines the requirements regarding the installation of the fire
                                       pumps which are used in fire protection. NFPA 20 covers the selection,
                                       installation, acceptance test, and operation of fire pumps.
    Material Properties
.
     Casing       :                      GG25 (Gray Cast Iron)                             cabinets.
.
     Impeller     :                      CuSn10 (Bronze) – AISI 304                        .
                                                                                              In the nominal flow rate, the rate of flow in the
.
     Shaft        :                       AISI 316 - AISI 420                              suction line is less than 3 m/s'.
.
     Shaft Bushing :                     AISI 316 - AISI 304                               In NFPA 20, suction line diameters of fire pumps
.
     Sealing      :                      Should be supplied together                       are specified according to the maximum speed
                                         with the soft packing ring with                   under 150% of the nominal flow rate. (4,6 m/sec).
                                         a minimum of five (5) windings.                    The service factor of electric motors (overload
.
     Bearing                           : Bearings should have a minimum                    factor) should not exceed 1.15.
                                         of 5000 hours lifetime in maximum                 .
                                                                                              There should be a OS & Y Gate Valve in between
                                         load condition.                                   the suction line and suction collector of fire
                                                                                           pumps.
What Are the Characteristics of a Pump System                                              .
                                                                                              Strainers should never be placed on the suction
That Complies with NFPA 20?                                                                line.
.
  Standard pump types are specified as Horizontal                                           .
                                                                                              On the discharge line of fire pumps, there should
Split Case Pump, Horizontal End-Suction Pump,                                              a check valve and butterfly valve, respectively.
Horizontal Multi-Stage End-Suction Pump,                                                   .
                                                                                              If the electric fire pumps with backup power
Inline Pump, and Vertical Turbine Pump.                                                    are selected, there should be a prime power
.
  Among the fire pumps, NFPA 20 allows                                                      source that will continue to supply the pumps
negative suction only for “Vertical Turbine                                                and cabinets. If there is no backup power source,
Pumps;” end-suction and split case pumps                                                   at least one of the pumps should have a diesel
should never be operated under negative                                                    engine.
suction.                                                                                   .
                                                                                              A Jockey pump is used to eliminate the minor
.
  The fire pump curve should ensure the 150%                                                pressure drops in the fire line without the need
capacity of the nominal flow rate, and the value                                            for activating the main fire pumps; its flow rate
of pressure at %150 flow rate capacity cannot be                                            should be minimum 1/100 of the flow rate of main
less than 65% of nominal pressure.                                                         fire pump, and its pressure should be at least 1
.
  The closed valve pressure value of fire pump                                              bar more than that of the main fire pump.
(the maximum pressure that the pump can
provide under zero flow rate) should not exceed
140% of the nominal value.
.
  Each pump should have independent control
                                                             Performance Curves
                                                                  Pump Characteristic Curve According to NFPA
                             140
                                                                   122
                                                                                                             Operating Point
                             120
                                                                                                    100
                             100
             Pump Head (%)
                             80
                                       Minimum allowed pressure                                                        82
                                                                                                                                    65
                             60
                             40
                                                                                         The Point to Determine the Motor Power
                             20
                              0
                                   0                                50                              100                           150
                                                                                  Nominal Flow Rate (%)
                                                                                               Pressure – Flow Rate Curve
                                                                                                                                            5
                                TS EN 12845 + A1
                            This European Standard had been prepared by technical committee
                            of Fixed Firefighting Systems and approved by CEN on 12 December.
                            CEN members are the national standards bodies of Austria, Belgium,
                            Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland,
                            France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latzia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom. Turkey Standard Enstitute fully stick to EN 12845 standarts therefore Turkey
Standard Enstitute entitled its document as TS EN 12845 . Some of base issues that a fire
pump set shall have are as follows.
.
    Pumps shall have stable H (Q) performance               switch. Two pressure switches shall be
    curve.                                                  provided to start each pumpset.
.
    The pump shall be capable of supplying              .
                                                            Where two pumps are installed, each one
    140% of this flow at a pressure of no less               shall be capable independently of providing
    than 70% of the pressure at the design pump             the specified flows and pressures. Where
    flow.                                                    three pumps are installed, each pump shall
.
    The pumps shall be start by pressure drop               be capable of providing at least 50 % of the
    in the system that is taken from pressure               specified flow at the specified pressure.
                                     Performance Curves
                            y
                    Pressure
                     100%
                                                   1x
                      70%
                                                             100%       140%       x
                                                                                 Flow
6
DSP
Horizontal Split Case Pump
    Material Properties
       Pump Casing           GG25 (Cast Iron) - GGG40 (Sferoo)
          Impellor           CuSn10 (Bronze) - GG25 (Cast Iron)
            Shaft                    AISI 420 - AISI 316
           Sealing                     Soft Packing
    Technical Properties
     Fluid Temperature                 -20 / +80 °C
       Power Supply              3 - 440 V, 50 Hz / 60 Hz
    Operating Pressure                    16 Bar
     Flow Rate Q (GPM)                  100 - 2.500
     Pressure Hm (PSI)                    76 - 189
     Motor Speed (rpm)                 1.450 - 3.000
       Suction Flange                DN 100 - DN 250
     Discharge Flange                DN 65 - DN 200
    System Equipment
     Air Discharge Valve          Check Valve               Jockey Pump           Pressure Switch
         Relief Valve             Manometer                 Expansion Tank          Pressurestat
    Product Specifications
.
    Pumps have double-suction, horizontal split case, and their suction-discharge flanges are aligned
    in the lower casing.
.
    Thanks to the optimized efficiency, provides low operating cost.
.
    Thanks to the low NPSH values, it allows cavitation-free operation.
.
    Impellers are balanced in accordance with ISO 1940 class 6.3.
.
    Has grease bearing and soft packing.
.
    The pump rotates clockwise according to the motor side.
.
    The equipment used in the suction and discharge lines is of ‘Duyar Valve' brand.
.
    Suction and discharge flanges comply with the ISO 7005-2/PN16 standard.
.
    Flanges can be optionally produced in ANSI norms.
                                                                                                       7
                                                              Performance Curves
                      180
                      160
                      140
                                                     10
                                                     0/
                                 80/315                31
                                                          5
                      120
    Pump Head (mSS)
                      100                                               125/315
                                60/250
                                                                                                200/500
                       80
                                                                                   15
                                                                                  0/3
                                               250
                                                                                  15
                                                                   0
                                                                 25
                                            80/
                                                              0/
                                                            10
                       60
                       40
                       20
                        0
                            0             200                   400       600             800             1000   1200   1400
                                                                       Flow rate (m /h)
                            DSP Series Horizontal Split Case Pump Set – NFPA 20
8
Horizontal Split Case Pump
                               “Split case”
                               construction
    “Efficient”
  impellor design
                            with the special
                             casing design
                         “High Efficiency=Low
                         Energy Consumption”
                               “Corrosion
                                resistant”
                              stainless cover
    Ease of
“Maintenance/
  Mounting/
 Dismantling”
                               “Ergonomic”
                                  design
 “High casting”
     quality
                                                9
DNP
Horizontal End-Suction Pump
    Material Properties
        Pump Casing                 GG25 (Cast Iron)
           Impellor         CuSn10 (Bronze) - GG25 (Cast Iron)
            Shaft                   AISI 316 - AISI 420
           Sealing                    Soft Packing
    Technical Properties
      Fluid Temperature               -20 / +80 °C
        Power Supply          380 - 440 Volt, 50 Hz / 60 Hz
     Operating Pressure                 5 - 14 Bar
      Flow Rate Q (GPM)                88 – 3.500
      Pressure Hm (PSI)                  70 - 197
      Motor Speed (rpm)             1.450 – 2.950 d/d
       Suction Flange               DN 50 - DN 250
      Discharge Flange              DN 32 - DN 200
    System Equipments
         Relief Valve            Manometer                Expansion Tank      Pressure Switch
         Check Valve            Jockey Pump               Pressure Switch       Presurestat
Ürün Özellikleri
.
     These are single-stage, end-suction, closed-impeller, axial pumps.
.
     Pump and motor connections are made on the common chassis using a flexible coupling.
.
     Equipped with grease bearings that have a long life.
.
     Soft packings are used for sealing.
.
     The pump rotates clockwise with reference to the motor side.
.
     The equipment used in the suction and discharge lines is of ‘Duyar Valve' brand.
.
     Suction and discharge flanges comply with the ISO 7005-2/PN16 standard.
10
                                                            Performance Curves
                  200
                  180
                  160                                                                   50
                                                                                          -3
                  140                                                                        15
                                                                                                                                  80
                  120                                      40                                            65                         -3                                                                  15
                                                             -3                                              -3                        15                          10                                      0-
                                                                15                                             15                                                     0-                                     31
Pump Head (mSS)
                  100                                                                                                                                                    31                                     5
                                                                                                                                                                             5
                   90                                                                                                                    80
                                       32                              40                                           65                      -2
                   80                    -2                                 -2                                          -2                    50                    10
                                            50                                50               50                            50                                         0-
                                                                                                                                                                           25
                   70                                                                             -25                                                                            0
                                                                                                         0                                                                                       12
                                                                                                                                                                                                   5-
                   60                                                                                                                                                                                 25
                                                                                                                                                                                                         0
                                                                                             50                                           80
                                                                       40                      -2                                                -2
                   50                                                    -2                         00                                             00
                                                                             00                                         65
                                                                                                                          -2
                                                                                                                              00                            10
                   40                                                                                                                                         0-                     12
                                                                                                                                                                 20                    5-
                                                                                                                                                                    0                      20
                                                                                                                                                                                             0
                   30
                    6
                        6   7 8 9 10             15   20          30         40    50                             100              150                200           300              400         500 600 750 900 1050
                                                                                   Flow rate (m /h)
                                   DNP Series End-Suction Pump Set -NFPA 20
                                                                                                                                                                                                                        11
DMP
Horizontal Multi-Stage Pump
    Material Properties
         Pump Casing            GG25 (Cast Iron) - GGG40 (Sfero)
            Impellor           CuSn10 (Bronze) - GG25 (Cast Iron)
             Shaft                    AISI 420 - AISI 41050
            Sealing                       Soft Packing
    Technical Properties
      Fluid Temperature                   -20 / +80 °C
        Power Supply             380 - 440 Volt, 50 Hz / 60 Hz
     Operating Pressure                    5 - 24 Bar
      Flow Rate Q (GPM)                    17.6 – 704
      Pressure Hm (PSI)                     70 -338
      Motor Speed (rpm)                 1.450 - 2.950 d/d
        Suction Flange                  DN 40 - DN 250
      Discharge Flange                  DN 32 - DN 200
    System Equipments
      Casing Relief Valve           Manometer                 Expansion Tank            Pressure Switch
          Check Valve               Jockey Pump               Pressure Switch              Presurestat
    Product Specifications
.
     Used in the projects where high pressure is required.
.
     Soft packing is used as a sealing element.
.
     Impellors are produced with balance holes to compensate the axial loads.
.
     Cylindrical roller bearings that have a long life and withstand heavy conditions are used in the pumps.
.
     The pump rotates clockwise with reference to the motor side.
.
     Suction and pressure flanges can be PN16, PN25, or PN40 if required.
.
     Case castings can be GG25 (CAST IRON) or GG40 (SFERO) according to the desired pressure.
12
                                                           Performance Curves
                                                                               2.900 d/d
                  450
                  400
                  350
                  300
                                                                      DM
                                                      DM                 P5
                  250                                   P4                 0
                                                           0                        DM
                  200                                                                   P6
                                   DM                                                      5
                                     P3
                                        2
                  150                                                                                 DM
                                                                                                         P8
                  100                                                                                      0
                   50
Pump Head (mSS)
                    0
                        6                                                          60                          600
                                                                               1.450 d/d
                    300
                    250
                    200                     DM                 DM
                                              P1                                               DM
                                                 25              P1                              P2
                                                                    50                              00
                    150
                    100
                        50
                         0
                             130                                                                               1300
                                                                         Flow rate (m3/h)
    DMP Series Horizontal Multi-Stage Fire Pump – Diesel Driven
                                                                                                                      13
CONTROL PANELS
Whether it is electric or diesel-driven, each pump is provided with manual or automatic controls
separately and independently through the electric and/or diesel control panel. Our panels are
produced according to the NFPA 20 standards. They are compact fire-fighting equipment suitable
for automation, easy to use, and maintain with the alarm and control features.
ELECTRIC-DRIVEN CONTROL PANEL
.
     Measuring and monitoring 3-phase voltage          .
                                                           Floater protection against the dry run, ‘Active’
     values                                                and ‘Passive’ selection
.
     Ability to save the recent twenty events in the   .
                                                           Ability to use a pressure transmitter
     memory, with the time and date information        .
                                                           With BMS feature, notification of all
.
     ‘Active’ and ‘Passive’ voltage protection             fault/operation conditions via relay contact
     selection                                         .
                                                           Turkish/English menu
.
     Ability to test twice a week                      .
                                                           Displaying date and time
.
     Pump monitoring                                   .
                                                           4x20 LCD display
.
     Monitoring pump operation time                    .
                                                           Automatic - Manuel operation switch
.
     Monitoring the number of pump starts/stops
14
DIESEL-DRIVEN CONTROL PANEL
.
    Double-battery system
.
    Current-voltage monitoring through the display
.
    Monitoring the temperature value via the temperature
    switch
.
    Monitoring the oil pressure with the oil pressure switch
.
    Monitoring the fuel status on display.
.
    Ability to limit the number of starts
.
    Ability to adjust the starting time
.
    Manual start/stop feature
.
    Diesel operation period monitoring through the display
.
    Ability to adjust the diesel stop delay (1-240 minutes)
.
    Low battery voltage notification
.
    Monitoring the diesel rotation (RPM) on display
.
    Ability to test twice a week
.
    Ability to use a pressure transmitter
.
    With BMS feature, notification of all fault/operation
    conditions via relay contact
.
    Turkish/English menu
.
    Displaying date and time
.
    4x20 LCD display
.
    Automatic - Manual operation switch
DMVP JOCKEY PUMP SET
These systems are used to continuously keep the
fire line under pressure. They also compensate
minor leakages on the line and prevent
start-stop operations of the fire pumps. This
product is supplied together with a vertical shaft
pump, expansion tank, control panel, and other
required equipment in a set and is included in
the fire pump set.
.
    Vertical Multi-Stage pump (with chassis)
.
    Electric motor
.
    Control panel
.
    100 lt expansion tank
.
    Ball valve
.
    Check valve
.
    Pressure Switch
.
    Level Floater
                                                               15
Quality , Reliable , Innovative