0% found this document useful (0 votes)
542 views1 page

Second Floor Isometric Sewer Line Layout Plan: For Permit

This document details a 150mm diameter vertical stack pipe running from the roof vent pipe down to connect other vertical stack pipes. It includes dimensions and labeling of the vent pipe and connecting vertical stack pipes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
542 views1 page

Second Floor Isometric Sewer Line Layout Plan: For Permit

This document details a 150mm diameter vertical stack pipe running from the roof vent pipe down to connect other vertical stack pipes. It includes dimensions and labeling of the vent pipe and connecting vertical stack pipes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

150mm ∅ VERTICAL STACK PIPE 1 150mm ∅ VERTICAL STACK PIPE

B 2
3

100mm ∅ VENT THRU ROOF PIPE

100mm ∅ VENT THRU ROOF PIPE


205
0

360
0 672
5
197
5 4 150mm ∅ VERTICAL STACK PIPE
150mm ∅ VERTICAL STACK PIPE 150mm ∅ VERTICAL STACK PIPE

C 800
0 367
5

100mm ∅ VENT THRU ROOF PIPE


140

100mm ∅ VENT THRU ROOF PIPE


0

100mm ∅ VENT THRU ROOF PIPE


225
0

150mm ∅ VERTICAL STACK PIPE


240 8000
0
5
D 800
0
SE 300
0

100mm ∅ VENT THRU ROOF PIPE


RV
WC
IC EC
00 FD

326 UR WC AN
OP
75 WC
Y 422
253
6
FD
FC LA
FD
WC 5
O FC V
O FD
WC
800
SK FD
WC 0
LA
FC V

E
O
0
800 SE
FD 10
RV 422
LA
V
0∅
PV ICE 5
50 CS
FC
O ∅
PV
OI
L PIP CA
CV
EN
E NO
FC
O TP
IPE PY
SK

10 150mm ∅ VERTICAL STACK PIPE


LA
V
FC
FD

O
WC

10
0∅
50

PV

PV
CV
EN FC
SK
150mm ∅ VERTICAL STACK PIPE
FC
O SK
800
0
565
00 7
0∅ CS TP O
OI

F
PV IP
0 LP
IPE E
800
CS
50

OI
LP
SE 108
PV
CV
IPE
RV 00
EN
ICE

100mm ∅ VENT THRU ROOF PIPE

100mm ∅ VENT THRU ROOF PIPE


TP
IPE
5 CA
362 NO
S
FC K
O
PY 150mm ∅ VERTICAL STACK PIPE

FC
O
SK
8 00
0
8

100mm ∅ VENT THRU ROOF PIPE


150mm ∅ VERTICAL STACK PIPE
SK 150mm ∅ VERTICAL STACK PIPE 150mm ∅ VERTICAL STACK PIPE
475
SE 0
RV

100mm ∅ VENT THRU ROOF PIPE


FC
O
ICE

100mm ∅ VENT THRU ROOF PIPE

100mm ∅ VENT THRU ROOF PIPE


SK
FC
O CA
NO
FD
PY
WC 10
205 50

9
0∅
0 SK
LA
V 10 ∅
0 ∅ PVC 50 PV 500
PV VE ∅
PV
CS
OI 0 800
6 C S NT LP
197 750
SK P CV
OI
L P IPE
IPE
SK EN
TP
IPE
0
IPE
5
SK
FC
O SE 300
RV
367
5 135 WC
ICE
CA
0
10
0
220
0 SE
FC
O
F
LA D
V
FC
O NO
PY
395 450
11
RV LA
V
0 0
ICE FD
WC
10
0
50 ∅ P
CA SK ∅ V
PV C SO
N OP SK C V IL
EN PIP 150
800 Y SK TP E
245 0
0 585 IPE
0
0 SK
FC LA SE
O LA
V F
F
FC WC D
V
50 RV
SK 50

D WC O ∅
PV
CV 1
ICE 232
10
0∅
PV
CV EN 00 ∅
FC CA 5
SE PV
CS
EN
TP
IPE LA
TP
IPE PVC
SO
O LA
VF N
D OP
RV OI
L PIP WCFD
V
50
IL
PIP Y
ICE E
FC
∅ 1
PV 00 ∅
CV
E
WC

587 CA O F
WC D
LA
V EN PVC
T P SO FC
5 NO IPE IL P
SK O
PY IPE SK

800 SK
0 FC
O SK
FC
LA WC O SK
V SK
FD FD L
WC A
FC VU 10
800
O R 0∅
PV
580 SE 50

C SO
0 RV PV
CV
IL
PI
EN PE 0
ICE TP
IPE 313
CA SK
NO FC
O
PY SK SK
0
800 SK 236 00
565 0 FC
O 80
00 SK
632 50 0
5 FC 10
0∅

PV
CV FC
251
O EN O
PV TP
SE CS
OI
IPE
SK
R VIC
SK LP
IPE
EC
AN SK SK
OP SK 50

SK
Y PV 0
800 860 00
10 CV
0∅ EN
0 585 T
0 PV
CS
OI
PIP
E 80
L PIP
E

217
5 00
342
225
0
800 0
0 800 8000
387
5

237
5
450
0
0
800 8000
150 5825
0
230
0
800

1 SECOND FLOOR ISOMETRIC SEWER LINE LAYOUT PLAN


P 33 SCALE 1:100M
0 2 4 6 8 10M
TOTAL FLOOR AREA = 2,227 SQM

FOR PERMIT
ARCHITECT MASTER PLUMBER PROJECT TITLE/LOCATION: PROJECT OWNER: OWNER REPRESENTATIVE: APPROVED BY: SHEET CONTENTS: REVISION: SHEET NO.
REG. NO.: 13388 REG. NO.: 4808 SECOND FLOOR ISOMETRIC SEWER LINE LAYOUT PLAN

TIN: 181246932 TIN: 232-944-625


ALLIED CARE EXPERTS
PROPOSED 8-STOREY W/ LOWER GROUND P
ALVIENTO + IGNACIO & ASSOCIATES FERDINAND A. IGNACIO JR. PTR NO.: 1698698 FERUEL T. PATALAGSA PTR NO.: 6404489
ACE
MEDICAL CENTER
HOSPITAL BUILDING (146 BEDS)
ALLIED CARE EXPERTS MEDICAL CENTER (ACEMC) - TUGUEGARAO
ALLIED CARE EXPERTS MEDICAL CENTER DR. JUAN FRANCISCO BELTRAN III -
ARCHITECTURAL & ENGINEERING DESIGN SOLUTIONS & INNOVATIONS ARCHITECT MASTER PLUMBER
TUGUEGARAO
A member of ACE Group of Hospitals
TUGUEGARAO PRESIDENT - ACEMC - TUGUEGARAO
3F NETHSQUARE BLDG. 2, ADDAS II, MOLINO II, BACOOR BLVD., BACOOR CITY
gmail: alviento.ignacio.associates@gmail.com contact nos.: 09266467494 / 09064669531
DATE:

PLACE:
03-07-19

BACOOR
DATE:

PLACE:
01-07-19

BACOOR
PALLUA ROAD, BRGY. PALLUA SUR, TUGUEGARAO CITY CAGAYAN
DRAWN/DESIGN BY:
FILE:
FAIJR CHECKED BY:
DATE:
33 39

G:\A+I FILES\TUGUEGARAO\CADD FILES\TUGUE_PLUMBING\TUGUEGARAO PLUMBING with ISOMETRIC jan.29,2019.dwg, 6/18/2019 9:43:34 AM, DWG To PDF.pc3