Air Conditioner Installation Guide
Air Conditioner Installation Guide
E-1
                                                                  • Always disconnect the air conditioner from the power supply before servicing
                                         WARNING                    it or accessing its internal components.
                                                                  • Verify that installation and testing operations are performed by qualified
                                                                    personnel.
                                                                  • Verify that the air conditioner is not installed in an easily accessible area.
                             GENERAL INFORMATION
                              Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to
                                 be able to use it as reference after installation.
                              For maximum safety, installers should always carefully read the following warnings.
                              Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air
                                 conditioner is sold or transferred.
                             This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of
                               units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be
                               responsible for damages arising from the use of non compliant units.
                              The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric
                               and requirements set forth in the “Operating limits” table, included in the manual, shall immediately invalidate the warranty.
                              The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to
                               be installed in areas used for laundry.
                              Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.
                              In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’
                               stechnical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.
                              Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations
                               should be performed by qualified personnel only.
                              The unit contains moving parts, which should always be kept out of the reach of children.
                              Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may
                               cause electric shocks or fires.
                              Do not place containers with liquids or other objects on the unit.
                              All the materials used for the manufacture and packaging of the air conditioner are recyclable.
                              The packing material and exhaust batteries of the remote control(optional) must be disposed of in accordance with current laws.
                              The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air condi
                               tioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.
                             INSTALLING THE UNIT
                             IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines.
                                             Always disassemble the electric lines before the refrigerant tubes.
                              Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged,
                               DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician
                               has collected the material from the retailer.)
                              After completing the installation, always carry out a functional test and provide the instructions on how to operate the air
                               conditioner to the user.
                              Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to
                               avoid the occurrence of fires, explosions or injuries.
                             POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER
                              Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in
                                compliance with current local safety standards.
                              Always verify that a suitable grounding connection is available.
                              Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is suf
                                 ficient to ensure the operation of any other domestic appliance connected to the same electric lines.
                              Always verify that the cut-off and protection switches are suitably dimensioned.
                              Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring
                                diagram included in the manual.
                              Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifica
                                 tions and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards
                                 applicable to the installation of air conditioners.
E-2
E-3
                      When deciding on the location of the air conditioner with the owner, the following restrictions
                      must be taken into account.
                      General
                      Do NOT install the air conditioner in a location where it will come into contact with the following elements:
                       Combustible gases
                       Saline air
                       Machine oil
                       Sulphide gas
                       Special environmental conditions
                      If you must install the unit in such conditions, first consult your dealer.
                      Outdoor Unit
                       The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into
                          the cooling circuit and seriously damage the unit.
                       Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.
                       Do not block any passageways or thoroughfares.
                       Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any
                          neighbours.
                       Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommend-
                          ed length will be respected.
                       Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary
                          noise and vibration.
                       Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top
                          of the unit.
                       Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.
                       Make sure that the water dripping from the drain hose runs away correctly and safely.
                          CAUTION
                              You have just purchased a Free Joint Multi air conditioner and it has been installed by your
                                 installation specialist.
                              This device must be installed according to the national electrical rules.
                              Max input power & current is measured according to IEC standard and input power & current is
                                 measured according to ISO standard.
                              More than 2 indoor units should be installed when you use Free Joint Multi air conditioner.
                             The units must be installed according to distances declared, in order to permit accessibility from
                               each side, either to guarantee correct operation of maintenance or repairing products. The unit’s
                               parts must be reachable and removable completely under safety condition (for people or things).
                              The cost needed to reach and repair the outdoor unit (in SAFETY CONDITION according to decree of
                               law 626/94) , installed above 3.0 meters height (from the floor) will be charged to final customer.
                              With an outdoor unit having net weight upper then 60kg,we suggest do not install it suspended on
                               wall, but considering floor standing one.
E-4
                                                                                                                                                                        ENGLISH
       MH040FXA2B
       MH040FXA2B outdoor unit cannot be connected to the following indoor unit combination.
         -052/MHFMA/MHFEA/MHFUA
                                                               200 mm
                                                               or more
                                    100 mm                                            160 mm
                                    or more                                           or more
                     CAUTION:
                     3 m as minimum pipe length: It will reduce                                                                          (h)   (H)
                     noise and vibration.
                     This value must be increased at 7.5 meters in
                     case it is connected just one indoor unit.
                                                 600 mm
                                                 minimum
                                                                              A                                             B
                  300 mm
                 minimum                                       300 mm
                                                               minimum
                  600 mm
                 minimum
       System can work with one indoor unit connected, but it is recommended that the TOTAL number of
       indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
E-5
MH050FXA2B
                   MH052FXA2B outdoor unit cannot be connected to the following indoor unit combination.
                     -MH052FMEA/MH052FUEA
                                                                       200 mm
                                                                       or more
                                            100 mm                                          160 mm
                                            or more                                         or more
                               CAUTION:
                               3 m as minimum pipe length: It will reduce                                                                            (h)   (H)
                               noise and vibration.
                               This value must be increased at 7.5 meters
                               in case it is connected just one indoor unit.
                                                          600 mm
                                                          minimum
                        300 mm                                         300 mm
                       minimum                                                        A                                               B
                                                                       minimum
                        600 mm
                       minimum
                   System can work with one indoor unit connected, but it is recommended that the TOTAL number
                   of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
E-6
                                                                                                                                                                              ENGLISH
       MH060FXA3B
                                                     200 mm
                                                     or more
                        100 mm                                          160 mm
                        or more                                         or more
                                      600 mm                     A
                                      minimum                                                                   B
                                                                                                                                            C
      300 mm
     minimum                                         300 mm
                                                     minimum
      600 mm
     minimum
       System can work with one indoor unit connected, but it is recommended that the TOTAL number
       of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
E-7
MH070FXA4B / MH080FXA4B
                                                                                200 mm
                                                                                or more
                                                                                                 160 mm
                                                     100 mm                                      or more
                                                     or more
                                                        600 mm
                                                        minimum                  A               B                                C           D
                        300 mm                                    300 mm
                       minimum                                    minimum
                       600 mm
                      minimum
                   System can work with one indoor unit connected, but it is recommended that the TOTAL number
                   of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
E-8
                                                                                                                                                                ENGLISH
         MH18VF1X/MH19VF1X                                                     Piping outside diameter
                                                          Power supply                                                    Outer Diameter
                Indoor unit           Outdoor unit                                             Unit
                                                            Ø, V, Hz                                                  Liquid           Gas
               MH18VF1-09              MH18VF1X                                         MH18VF1-09
               MH19VF1-07                                 1,220-240~, 50                MH19VF1-07                        1/4"            3/8"
                                       MH19VF1X                                         MH19VF1-12
               MH19VF1-12
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
                       CAUTION:                                                         B-unit
                       3 m as minimum pipe length: It will reduce                                      MH18VF1-09 or
                       noise and vibration.                                                            MH19VF1-12
                       This value must be increased at 7.5 meters
                       in case it is connected just one indoor unit.
                                                     200 mm
                                                     or more
                                                                   A-unit MH19VF1-07 or
                                                                            MH18VF1-09
                                                                                                                    (h)            (H)
                         100 mm                                                      160 mm
                         or more                                                     or more
                                         600 mm                        A                           B
                                         minimum
           300 mm                                       300 mm
           minimum                                      minimum
            600 mm
            minimum
        System can work with one indoor unit connected, but it is recommended that the TOTAL number
        of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
E-9
300 or more
                                                                                                                                                          1500 or more
                                                    When the air outlet is opposite the wall         When the air outlet is towards the wall
                                                                                                                                      1500 or more
                                             300 or more
2000 or more
                                                    When 3 sides of the outdoor unit are             The upper part of the outdoor unit and
                                                            blocked by the wall                            the air outlet is towards the wall
                                                                                                                                                     300 or more
                                              500 or more
300 or more
1500 or more
                                                    The upper part of the outdoor unit and           When front and rear side of the outdoor
                                                            the air outlet is opposite the wall            unit is towards the wall
E-10
                                                                                                                                                                         ENGLISH
       When installing more than 1 outdoor unit
                                                                                                                          Unit : mm
                                                                            1500 or more
                When the air outlet is towards the wall
                                                                                                                      300 or more
              300 or more            600 or more     600 or more     600 or more
                 When 3 sides of the outdoor unit are blocked by the wall
                                                                                           1500 or more 300 or more
 When front and rear side of the outdoor unit is towards the wall
          1500 or more        600 or more      3000 or more          3000 or more                                                   200 or more
                When front and rear side of the outdoor unit is towards the wall
         500 or more
                       300 or more
        500 or more
300 or more
E-11
                            MH070FXA4B / MH080FXA4B
                                   3-wire                  2-wire                  Drain Plug           Transmitter power        Installation Manual
                                Power Cable            Assembly Cable                                         cable
                                  (option)                (option)
                                Rubber Leg            Flare Nuts, 6.35mm        Flare Nuts, 9.52mm           Flare Bolt             Energy Label
                                                      outer pipe diameter       outer pipe diameter     (Nut 1/2”, Bolt 3/8”)
                                The 3-wire power cable and the 2-wire assembly cable are optional. If these cables are not supplied, use the
                                 standard cable approved by IEC standard.
                                 Please, check “Connecting the Cables to the Outdoor Unit” section.
E-12
                                                                                                                                           ENGLISH
       While heating, ice may accumulate. During the process of defrosting, check if
       condensation draining is adequate. For adequate draining, do the following:
1 Insert the drain plug into the drain hole on the underside of the outdoor unit.
����������
E-13
                                             1   Make sure that you have the required tools available (pipe cutter, reamer,
                                                 flaring tool and pipe holder).
                                             2   If you wish to shorten the piping, cut it using a pipe cutter, taking care to
                                                 ensure that the cut edge remains at a 90° angle with the side of the pipe,
                                                 and referring to the illustrations below for examples of edges cut correctly
                                                 and incorrectly.
                                                                           Oblique                       Rough                 Burr
                                                   ��
                                                     �
O x x x
                                             3   To prevent any gas from leaking out, remove all burrs at the cut end of the
                                                 pipe, using a reamer.
                                             5   Check that the flaring is correct, referring to the illustrations below for examples of incorrect
                                                 flaring.
� � � �
                                             6   Align the pipes to be connected and tighten the flare nuts first manually and
                                                 then with a torque wrench, applying the following torque.
                                             7   For further details on how to connect up to the outdoor unit and purge the circuit, refer to
                                                 page 23.
In case welding the pipe, the gas nitrogen must be blown into the parts.
E-14
                                                                                                                                                                                            ENGLISH
       When you install the unit, make first refrigerant connections and then elec-
           trical connections.Connect the air conditioner to grounding system before
           performing the electrical connection.If unit is uninstalled first disconnect
           electrical cables, then refrigerant connections.
       2 electric cables must be connected to the outdoor unit:
       The assembly cable connecting the indoor unit to the outdoor unit.
       The power cable connecting the auxiliary circuit breaker to the outdoor unit.
       1    Remove the cabinet side RH of the outdoor unit.
       2    Connect the assembly cable with the power cable such as figure.(40~70kgf.m)
             Each wire is labelled with the corresponding terminal number.
             Ensure the wire number of the indoor unit and the terminal number of the outdoor unit.
       3    Connect the earth wires to the earth terminals.
             Refer to the page 22 for further details on how to check that earthing is correct.
       4    Fix the cables with cable clamps near terminal blocks to protect the wire
            connection to the terminals from force on the wire.
       5    Replace the terminal board cover, carefully tightening the screw.                                                               The designs and shape are subject to
       6    Connect the power cable to the auxiliary circuit breaker.                                                                         change according to the model.
       MH040FXA2B/MH050FXA2B/MH18VF1X/MH19VF1X
                                                  A-unit                         Indoor unit                          B-unit
                                                                                     Assembly cable
                                     1     2                        F1 F2                                  1   2                        F1 F2
                                                       Earth                                                            Earth
                                                       terminal                                                         terminal
                                               B                         C                                 B                           C
                                     1     2                        F1 F2                                  1   2                        F1 F2
                                                   Earth                                                              Earth
                                                   terminal                                                           terminal
                                                                                            Outdoor unit
                     1(L) 2(N) 1(L) 2(N)                                                                                         F1 F2 F1 F2
                                                                             L          N   Main Power
                                                                                            supply cable
                        �        �                                                                                                �         �
               Power cable to indoor units                                       1      2                               Communication cable
                                                                                             Earth                        to indoor units
             � Cable Type: A                                                                 terminal
             � Cable Type: B                                                 A
             � Cable Type: C
MH060FXA3B
                                                                                                                      Assembly cable
                               1    2                          F1 F2           1       2                    F1 F2                             1   2                           F1 F2
                               1    2                          F1 F2           1      2                     F1 F2                             1   2                           F1 F2
                                                                                           Earth                                                      Earth
                                        Earth                                              terminal                                                   terminal
                                        terminal
Outdoor unit
                             � Cable Typeυ: A
                             � Cable Type: B
                             � Cable Type: C
E-16
                                                                                                                                                                                                                ENGLISH
       MH070FXA4B / MH080FXA4B
                                                                                             Assembly cable
         1   2                        F1 F2         1    2                        F1 F2                              1   2                      F1 F2        1    2                         F1 F2
1 2 F1 F2 1 2 F1 F2 1 2 F1 F2 1 2 F1 F2
Outdoor unit
                                                                                                          Main Power
                            1(L) 2(N) 1(L) 2(N) 1(L) 2(N) 1(L) 2(N)                                                                                 F1 F2 F1 F2        F1 F2 F1 F2
                                                                                              L      N    supply cable
                                                                                                                                                     A      B               C          D
                                 A        B       C          D
                                                                                                 1   2                                                   Communication cable
                                Power cable to indoor units
                                                                                                          Earth                                            to indoor units
                                                                                                          terminal
                                                                                             A
       � Cable Type: A
       � Cable Type: B
       � Cable Type: C
E-17
                                                         B              60        60         80
                                                                                                        For
                                                         C              70        70      110     060/070/080
                                                                                                        only
                                                                                                        For
                                                         D              90        90         90    070/080
                                                                                                        only
                                                 Communication cable to indoor units : L(mm)
                                                      Cable of
                                                                             1           2              Remark
                                                    indoor unit
E-18
                                                                                                                                                          ENGLISH
        MH040FXA2B/MH18VF1X/MH19VF1X
       Accessories (Transmitter: MIM-B13)
           Transmitter         Transmitter power         Transmitter        Installation Manual   Case                     Cable-tie
                                     cable            communication cable
                                                                                                         Bolts spec.
                                                                                                                                  7seg. LED
       1    Fix the case at with bolts on the side of the control box in the outdoor unit.                M4
                                                                                                                                  Display side
            (See the picture)
       2    Attach the transmitter PCB to the case in the control box in the outdoor
                                                                                                                       Terminal
                                                                                                                                       Transmitter
            unit, then connect the power and the communication cable between the                                       side
            transmitter and the outdoor unit; refer to the figure of page 19.
       4    Each outdoor unit connected to the same centralized controller has its
            own transmitter.
E-19
                  MH050FXA2B/MH060FXA3B/MH070FXA4B / MH080FXA4B
                 Accessories(Transmitter: MIM-B13)
                    Transmitter              Transmitter power      Transmitter        Installation Manual           Case                 Cable-tie
                                                   cable         communication cable
MH050FXA2B
                              Terminal
                              side
Transmitter
                                      7seg. LED
                                      Display side
                             Bolts spec.
                             M4
                                                                 1    Fix the case with bolts on the control box in the outdoor unit.
                                                                      (See the picture)
                                                                 2    Attach the transmitter PCB to the case in the control box in the outdoor
                                                                      unit, then connect the power and the communication cable between the
                                                                      transmitter and the outdoor unit; refer to the figure of page 19.
                      Fix the case with bolts                    3    If you install a transmitter to an outdoor unit, every indoor unit which is
                 (Control Box in the outdoor unit)                    connected to an outdoor unit can be controlled simultaneously.
      MH060FXA3B/MH070FXA4B / MH080FXA4B
                                                                 4    Each outdoor unit connected to the same centralized controller has its
                           Terminal                                   own transmitter.
                           side              Transmitter
                                           7seg. LED
                                           Display side
E-20
                                                                                                                                                                              ENGLISH
                                                                                              CN01
                                         (Accessory in the outdoor unit)
                                                                                              (Whit)
         Transmitter    CN03
                        (Blue)
               PCB
                                                                                                                  MH040FXA2B                          CN01
                                                             MH050FXA2B/MH060FXA3B                                                                   (Whit)
                                              Center         MH070FXA4B/MH080FXA4B                            MH18VF1X/MH19VF1X
                                              Controller                                                         Outdoor unit PCB
                                                      Transmitter communication
       One housing is used for connection             cable (Accessory in the
       although there are 2 housings on the
       communication cable.                           transmitter)
Terminal Block in the outdoor unit Terminal Block in the outdoor unit Terminal Block in the outdoor unit
K1 K2 K3 K4
E-21
                                                                   4     Install a green/yellow insulated earthing wire (Ø1.6 mm, section 2 mm2 or greater):
                                                                          If the earthing wire is too short, connect an extension lead, soldering the connec
                                                                              tion and wrapping it with insulating tape (do not bury the soldered connection)
                                                                          Secure the earthing wire in position with staples
                                                                          If the earthing electrode is installed in an area of heavy traffic, its wire
                                                                               must be connected securely.
                                                                   5     Carefully check the installation, by measuring the earthing resistance with
                                                                         an earthing resistance tester. If the resistance is above the required
                                                                         level(Example:100Ω), drive the earthing electrode deeper into the ground
                                                                         or increase the number of earthing electrodes.
                                                                   6     Connect the earthing wire to the earthing screw on the air conditioner.
                             Rubber leg                            1     Position the outdoor unit so that the air flow is directed towards the
                                                                         outside, as indicated by the arrows on the top of the unit.
                    Model             X               Y            2     Attach the outdoor unit to the appropriate support using anchor bolts.
          MH040FXA2B
          MH18VF1X                   543             319
          MH19VF1X                                                 3     If the outdoor unit is exposed to strong winds, install shield plates around
          MH050FXA2B                                                    the outdoor unit, so that the fan can operate correctly.
          MH060FXA3B
          MH070FXA4B                660             350
          MH080FXA4B                                                                Certainly fix up its rubber leg in order to prevent its vibration
                                                                                      and noise.
                                      Designed to cut off
                                      residual vibration from          OUTDOOR UNIT INSTALLED ON THE WALL BY RACK
                                      outdoor unit to rack. (not
                                      supplied with product)
                                                                       - Ensure the wall will be able to suspend the weight of rack and outdoor unit;
                                                                       - Install the rack close to the colum as much as possible;
                                                                       - Install proper grommet in order to reduce noise and residual vibration trans-
                                                                         ferred by outoor unit towards wall.
           Soft rubber designed to cut
         off vibration from rack to wall.
           (not supplied with product)
E-22
                                                                                                                                       ENGLISH
       The outdoor unit is loaded with sufficient R410A refrigerant.Do not vent
       R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto
       Protocol, with a Global Warming Potential (GWP) = 1975.
       You should purge the air in the indoor unit and in the pipe.
       If air remains in the refrigerant pipes, it affects the compressor. It may cause
       reduction of cooling capacity and malfunction.
       Refrigerant for air purging is not charged in the outdoor unit.
       Use Vacuum Pump as seen in the picture.
        MH040FXA2B / MH052FXA2B / MH18VF1X/MH19VF1X
        1 Check the piping connections.
        2 Connect the charging hose of low pressure side of manifold gauge to the
           packed valve having a service port (MH040FXA2B:3/8” service valve 2EA;                      Indoor
                                                                                                        A-unit
           MH052FXA2B:3/8” service valve 1EA+1/2” service valve 1EA) as shown at
                                                                                                        Indoor
           the figure.                                                                                  B-unit
           WARNING:
           Make the electrical connection and leave the system into “stand by mode”. Do
           not turn on the system!.                                                                               Vacuum
           This is necessary for better vacuum operation (full OPEN position of Electronic                         Pump
           Expansion Valve - EEV -).
3 Open the valve of the low pressure side of manifold gauge counter-clockwise.
        4 Purge the air from the system using vacuum pump for about 10 minutes.                     Valve stem
           - Close the valve of the low pressure side of manifold gauge clockwise.
           - Make sure that pressure gauge show -0.1MPa(-76cmHg) after about 10
             minutes.                                                                                  Stem cap
             This procedure is very important in order to avoid gas leak.
           - Turn off the vacuum pump
           - Remove the hose of the low pressure side of manifold gauge.
                                                                                             Service port
        5 Set valve cork of both liquid side and gas side of packed valve to the open
           position.
        6 Mount the valve stem nuts and the service port cap to the valve,
           and tighten them at the torque of 183kgf•cm with a torque wrench.
E-23
                                                      2 Connect the charging hose of low pressure side of manifold gauge to the
                                                         packed valve having a service port (5/8” Packed valve) as shown at the
                                                         figure (Value stem: 1/2” - 20UNF).
                                                         WARNING:
                                                         Make the electrical connection and leave the system into “stand by mode”. Do
                                                         not turn on the system!.
                           A                             This is necessary for better vacuum operation (full OPEN position of Electronic
                            B
                             C
                                                         Expansion Valve - EEV -).
                                            Vacuum    3 Open the valve of the low pressure side of manifold gauge
                                             Pump        counter clockwise.
                                                      4 Purge the air from the system using vacuum pump for about 30 minutes.
                                                        - Close the valve of the low pressure side of manifold gauge clockwise.
                                                        - Make sure that pressure gauge show -0.1MPa(-76cmHg) after about
                                                          30 minutes.
                                    Valve stem            This procedure is very important in order to avoid gas leak.
                                                        - Turn off the vacuum pump.
                                                        - Remove the hose of the low pressure side of manifold gauge.
                                 Stem cap
                                                      5 Set valve cork of both liquid side and gas side of packed valve to the open
                                                        position.
                                                      6 Mount the valve stem nuts and the service port cap to the valve, and tighten
                             Service port                them at the torque of 183kgf•cm with a torque wrench.
Adding Refrigerant
                                                     If you install the excessive length of pipe, add additional refrigerant as 10g per unit
                                                     meter ; refer to the table below.
E-24
                                                                                                                                                                 ENGLISH
       Protocol. Do not vent gases into the atmosphere.
                                                                                                        Refrigerant type               GWP value
       CAUTION :                                                                                              R410A                        1975
       Inform user if system contains 3 kg or more of fluorinated greenhouse gases. In this
       case, it has to be checked for leakage at least once every 12 months, according to               GWP=Global Warming Potential
       regulation n¢X842/2006. This activity has to be covered by qualified personnel only.
                                                                                                        Contains fluorinated greenhouse gases
       In case situation above (3 kg or more of R-410A), installer (or recognised person                covered by the Kyoto Protocol.
       which has responsability for final check) has to provide a maintenance book, with all
       the information recorded according to REGULATION (EC) N¢X 842/2006 OF THE EU-                        Indoor unit
       ROPEAN PARLIAMENT AND OF THE COUNCIL of 17 May 2006 on certain fluorinated
       greenhouse gases.
        Please fill in with indelible ink,                                                                                         
                                                                                                                                       d        
        - the factory refrigerant charge of the product,
        - the additional refrigerant amount charged in the field and                                        a                            Outdoor unit
        - + the total refrigerant charge.                                                             = (           ) kg
          on the refrigerant charge label supplied with the product.                                                          + = (               ) kg
           Note a. Factory refrigerant charge of the product: see unit name plate                       = (           ) kg
                                                                                                              b                             c
                    b. Additional refrigerant amount charged in the field
                       (Refer to the above information for the quantity of refrigerant
                        replenishment.)
                    c. Total refrigerant charge
                    d. Refrigerant cylinder and manifold for charging
         The filled-out label must be adhered in the proximity of the product
          charging port (e.g. onto the inside of the stop valve cover).
       Before opening valves, discharge all the nitrogen into the system and create vacuum
       according to page 23 ~24.
       After opening valves, check leaks using a leak detector for refrigerant.
                                                                                                                      MH060FXA3B
       PUMP DOWN (before disconnecing t the refrigerant connections for unit repair,
       removal or disposal)
       Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit.
       This operation must be carried out before disconnecting the refrigerant pipe in order
       to avoid refrigerant loss to the atmosphere.
                                                                                                                              A
       - Shut off all the liquid valve with the Allen wrench.                                                                  B
                                                                                                                                C
           The designs and shape are subject to change according to the model.
                                                                                                                              A
                                                                                                                               B
                                                                                                                                C
E-25
                                                       MH070FXA4B / MH080FXA4AB
                                                      Follow different orders depending on the capacity of indoor units.
                                                      MH052FEA
                                                        Install pipes between indoor and outdoor units orderly as [ CD].
                                                      Examples
                                             A unit    2Rooms: MH035FVEA+MH052FVEA
                                             B unit
                                                           A         MH035FVEA                 A
                                             C unit                                                     MH052FVEA
                                                           B                                   B
                                                                                                         MH035FVEA
                                             D unit        C                                   C
                                                                    MH052FVEA
                                                           D                                   D
(o) (x)
                                                           A         MH035FVEA
                                                           B
                                                                    MH052FVEA
                                                           C
                                                                     (x)
                                                         3Rooms: MH026FVEA+MH035FVEA+MH052FVEA
                                                           A         MH026FVEA                 A         MH052FVEA
                                                           B                                   B
                                                                     MH035FVEA                           MH035FVEA
                                                           C                                   C
                                                                     MH052FVEA                           MH026FVEA
                                                           D                                   D
(o) (x)
E-26
                                                                                                                                               ENGLISH
       To complete the installation, perform the following checks and tests
       to ensure that the air conditioner is operating correctly.
        Step 2     IMPORTANT!
                   Before selecting switch turn off the system power supply
SW01 SW01
                                                                K1
             Switch
                           DIS01                 DIS02
                                                                         SW 02
                                                                        Manual          - Move dip switch
                                     SW02           SW01
                                                                       addressing       n°1 of “SW02
                                                                                        - outdoor unit dis-
                                                                K1                      play PCB” down;
             Switch
                            DIS01                 DIS02
            Indoor unit
               address
                                                                      Move down the
                                                                      switch n°1
                                     K2     K3             K4
Step 3 Follow of indication reported into table below for indoor unit addressing
        Step 4     Turn on the system power supply and waiting for 60 seconds after estabi-
                   lishing communication between outdoor and indoor units.
                   During this phase, the left display of outdoor unit display PCB “DIS01” will
                   count fom 00--01--02 to 15.
                   Estabilished communication the left display will count sequentially:
                   00--communication with indoor unit A;
                   01--communication with indoor unit B;
                   02--communication with indoor unit C;
                   03--communication with indoor unit D;
       In case of Manual address mode,you can do pipe check operation for check
          whether you connect the pipes correctly or not.
          But you need set indoor address switch yourselves.
                                                                                                                                  E-27
                                                        MH020FV(N)EA
                                                         MH023FBEA
                       RAC                             MH026FB(V/N)EA
                                                       MH035FB(V/N)EA
                                                       MH052FB(V/N)EA
                                                         MH026FKEA
                 1 WAY CASSETTE
                                                         MH035FKEA
                                                        MH030FMEA
                   MINI 4 WAY                           MH035FMEA
                                                        MH052FMEA
                                                         MH026FJEA
                    CONSOLE
                                                         MH035FJEA
E-28
                                                                                                                                               ENGLISH
        ROTARY SWITCH “SW02” POSITION ACCORDING TO REFRIGERANT CIRCUIT
                             CONNECTED ( 0=A; 1=B; 2=C; 3=D )
                    OUTDOOR UNIT                    Indoor Unit
                                                        SW02
                                    A unit
B unit
                                                    Indoor Unit
                    OUTDOOR UNIT
                                                        SW02
                                      A unit
                                      B unit
                                      C unit
                                                    Indoor Unit
                      OUTDOOR UNIT                      SW02
                                         A unit
                                         B unit
                                         C unit
                                         D unit
                                                                            It could take maximum 60 minutes to operate for the protection of the compressor
                                                                            if the outdoor temperature is below -5°C.
                                                                      Ampere Limit Setting & Changing Procedure
                                                                         WARNING
                                                                       Do not adjust the “Ampere Limit Switch”, if it’s not necessary: before modifying
                                                                        it, evaluate the total number of electric and electronics loads consumption and
                                                                        use “Ampere limits switch” just as emergency solution or in case the system is
                                                                        anyway oversized compared to real thermal load needed.
                                                                       “Ampere Limit Switch” is initially set to the default value (table below).
                                                                       “Ampere Limit Switch” is on the PCB of outdoor unit.
         The designs and shape are subject to
           change according to the model.                              Contact the authorized service technician or dealer for setting and changing
                                                                        the “Ampere Limit Switch”.
                                                                       Before changing the “Ampere Limit Switch”, turn off the main power of the system.
E-30
                                                                                                                                            ENGLISH
       Switch the system on and wait for code "       " to appear on the display of                       Red Button K1
         the external unit (this requires approximately 60 seconds **).
       As soon as code "          "displays, press once the red button (K1) shown on
         the figure on the side of the page:
                                        WARNING !!
                            If the quantity of indoor units connect-
                            ed is lower than maximum connectable
                            to outdoor unit, the rotary switch SW01
                            has to be positioned, in order to select a
                            number equal to indoor units’ quantity                                              SW01
                            you connected.
        After the operations described above have been performed, the system starts
            in Cooling or Heating mode, depending on the external ambient temperature.
            After a few minutes (from a minimum of 3 to 5 minutes for the internal              Display 1          Display 2
            unit), the system stops automatically, completing the self-test and addressing
            procedure.
        "         " appears on the display of the external unit.
       20 seconds after the display of "        " (that confirms the correct execution
         of the procedure), the following codes (if four internal units are connected) dis
         play in sequence on the display of the external unit:
       If "       "doesn’t display, the procedure has failed and it is therefore
            necessary to read ALL the operator’s manual before repeating the operating
            described in steps 1-2-3-4.
E-31
                                                             K1
              Switch                                                                  Pipe Checking Operation   Heat Mode Try run
                                                                            1
                         DIS01                  DIS02                                     (Display:     )        (Display:     )
          Indoor unit
                                                                                                                Refrigerant Charging
             address                                                                                                                                             View mode
                                                                            2                   -                (Display:        )             Reset
                                                                                                                                                                   change
                                                                                                                 Cool Mode Try run
                                 K2        K3           K4
                                                                            3                   -                (Display:       )
                                        View data display                                                           Pump down
                                                                            4                   -                (Display:    )
                  Outdoor PCB Display
                                                                     Heat and Cool Mode Try run functions are just For Service Technician
E-32
Troubleshooting
                                                                                                                                                 ENGLISH
       The table below give indication about self diagnostic routine. Some of error code requires activities
       exclusively for Authorise Service Center.
       The error indicated on the PCB display of outdoor unit
         DISPLAY     EXPLANATION (The error indicated on the PCB display of outdoor unit)                    REMARK
                                                                                                     Check electrical connection
                     Communiaction error(indoor unable to receive data)
                                                                                                     and setting
                     Outdoor unit communication error                                                Check electrical connection
                     (Abnormal data from indoor unit over 60 packet)                                 and setting
                     Indoor unit room temperature sensor error (Open/Short)
                     Indoor unit heat exchanger in temperature sensor error (Open/Short)
                     Indoor unit heat exchanger out temperature sensor error (Open/Short)
                     Indoor unit sensor error-Evaporator pipe in sensor - Self diagnosis
                     Indoor unit sensor error-Evaporator pipe out sensor - Self diagnosis
                     Indoor Unit FAN Error
                     More than two indoor units cool and heat simultaneously
                     Indoor Unit EEPROM Error
                     Indoor Unit EEPROM Option Error
                                                                                                     Check piping connection
                     Failure of pipe check operation
                                                                                                     and setting
                     No pipe check operation check
                     - occasion : try to operation after the installation through auto addressing Check setting
                     mode without pipe check operation.
                                                                                                  Check electrical
                     The number of Indoor unit mismatched
                                                                                                  connection and setting
                                                                                                  Check electrical
                     Communication error between the outdoor and indoor unit
                                                                                                  connection and setting
                     Outdoor communication error between main PCB and sub PCB
                     Outside temperature sensor error(Short/Open)
                     - Error level: over 4.9V(-50°C) under 0.4V(93°C)
                     Condenser temperature sensor error(Short/Open)
                     - Error level: over 4.9V(-50°C) under 0.4V(93°C)
                     Outdoor unit sensor error - Condenser out sensor(Short/Open) - Self diagnosis
                     Compressor Discharge temperature sensor error
                     Compressor discharge sensor detached - Self diagnosis
                     Compressor OLP sensor error (Short/Open)
                     - Error condition : outdoor temperature under -20°C
                     - Error level : over 4.95V(-30°C) under 0.5V(151°C)
E-33
                             Troubleshooting (Cont.)
                           The table below give indication about self diagnostic routine. Some of error code requires activities
                           exclusively for Authorise Service Center.
                             DISPLAY     EXPLANATION (The error indicated on the PCB display of outdoor unit)              REMARK
                                                                                                                check pipe lenght, indoor
                                         Outdoor unit freezing(Compressor stop)                                 unit filter, refrigerant leakage/
                                                                                                                charge and service port
                                                                                                                check pipe lenght, refrigerant
                                         Outdoor unit overload - Safety control(Compressor stop)
                                                                                                                leakage/charge
                                         Outdoor unit high discharge temperature - Safety control               check pipe lenght, refrigerant
                                         (Compressor stop)                                                      leakage/charge
                                         Outdoor unit EEV open (Stopped indoor unit’s) -Self diagnosis
                                         Outdoor unit EEV open (operating indoor unit’s) -Self diagnosis
                                         High temperature(over 30°C) of outdoor as heating mode
                                         Low temperature(under -10°C) of outdoor as cooling mode
                                         Outdoor Fan Error
                                         Communication cable mismatched between indoor
                                                                                                                Check electrical connection
                                         and outdoor unit
                                         Inverter compressor starting failure (5 times)
                                         Compressor trip by input current control mode (PFC over current)
                                         Compressor trip by OLP temperature control mode
                                         DC peak error (IPM Over Current)
                                         Compressor Vlimit Error
                                         DC link Voltage error (under 150V, over 410V)
                                         Abnormal compressor running
                                         (Compressor Rotation Error)
                                         Current sensor error
                                         DC link Voltage sensor error
                                         OTP Error
                                         Inverter micom zero-crossing error
                                                           Once the owner is happy with the basic operations, hand over the owner’s
                                                            instruction booklet and this installation manual for storage in a handy and
                                                            safe place.
E-34
ENGLISH
E-35
                                                                                              ENGLISH
                                                     Free Joint      Fixed
                                                     MH040FXA2B     MH18VF1X
                                                     MH050FXA2B     MH19VF1X
                                                                                              ESPAÑOL
                                                     MH060FXA3B
                                                     MH070FXA4B
                                                     MH080FXA4B
                                                                                              FRANÇAIS
                                                                                              ITALIANO
                                                                                              PORTUGUÊS
                                                                                              DEUTSCH
                      Free Joint Multi & Multi-Split Type Room Air Conditioner
                                             (Cooling and Heating)
EΛΛHNIKA
E S F I P D G DB98-28896A(3)