Engineering Standard
SAES-M-006 30 November, 2003
Saudi Aramco Security
and General Purpose Fencing
Civil Standards Committee Members
Al-Mehthel, M.H., Chairman
Abu-Adas, H.A.
Abulhamayel, I.A.
Addas, K.M.
Al-Darwish, A.
Al-Idi, S.H.
Al-Ismail, A.A.
Al-Khunaini, A.M.
Al-Moumen, A.A.
Al-Saffar, S.A.
Grosch, J.J.
Kassam, E.M.
Saudi Aramco DeskTop Standards
Table of Contents
1 Scope............................................................. 2
2 Conflicts and Deviations................................. 2
3 References..................................................... 2
4 Design............................................................ 3
5 Installation...................................................... 5
Previous Issue: 29 January, 2003 Next Planned Update: 1 February, 2008
Revised paragraphs are indicated in the right margin Page 1 of 7
Primary contact: Ismat Abulhamayel on 873-6905
Document Responsibility: Civil SAES-M-006
Issue Date: 30 November, 2003 Saudi Aramco Security
Next Planned Update: 1 February, 2008 and General Purpose Fencing
1 Scope
1.1 This Standard covers mandatory requirements governing the design and
installation of Saudi Aramco Security and general purpose fencing, and shall be
used to select the most appropriate type of Saudi Aramco fencing for protection
of nonvital or nonsensitive facilities.
1.2 Fencing for vital or sensitive facilities, as defined in SAES-O-100, General
Requirements Safety and Security Standards, shall be in accordance with the
Saudi Aramco Safety and Security Standards, SAES-O-Series.
2 Conflicts and Deviations
2.1 Any conflicts between this standard and other applicable Saudi Aramco
Engineering Standards (SAESs), Materials System Specifications (SAMSSs),
Standard Drawings (SASDs), or industry standards, codes, and forms shall be
resolved in writing by the Company or Buyer Representative through the
Manager, Consulting Services Department of Saudi Aramco, Dhahran.
2.2 Direct all requests to deviate from this standard in writing to the Company or
Buyer Representative, who shall follow internal company procedure SAEP-302
and forward such requests to the Manager, Consulting Services Department of
Saudi Aramco, Dhahran.
3 References
The selection of material and equipment, and the design, construction, maintenance, and
repair of equipment and facilities covered by this standard shall comply with the latest
edition of the references listed below, unless otherwise noted.
Saudi Aramco Documents
Saudi Aramco Engineering Procedure
SAEP-302 Instructions for Obtaining a Waiver of a
Mandatory Saudi Aramco Engineering
Requirement
Saudi Aramco Engineering Standards
SAES-O-Series Safety and Security Standards
SAES-O-100 General Requirements Safety and Security
SAES-P-111 Grounding
SAES-Q-001 Criteria for Design and Construction of Concrete
Structures
Page 2 of 7
Document Responsibility: Civil SAES-M-006
Issue Date: 30 November, 2003 Saudi Aramco Security
Next Planned Update: 1 February, 2008 and General Purpose Fencing
Saudi Aramco Materials System Specifications
09-SAMSS-097 Ready-Mixed Portland Cement Concrete
12-SAMSS-021 Saudi Aramco Security and General Purpose
Fencing (Galvanized)
12-SAMSS-022 Saudi Aramco Security and General Purpose
Fencing (Vinyl-clad Galvanized)
Saudi Aramco Standard Drawings
AB-036677 Saudi Aramco Security and General Purpose
Fencing - General
AA-036678 Saudi Aramco Security and General Purpose
Fencing - Post and Fabric Details
AB-036679 Saudi Aramco Security and General Purpose
Fencing - Gate Details
AC-036680 Saudi Aramco Security and General Purpose
Fencing - Footings Details
AE-036881 L/M for Saudi Aramco Security Fencing Type I
AE-036882 L/M for Type II Fencing
AE-036883 L/M for Type III Fencing
AE-036884 L/M for Type IV Fencing
AE-036904 L/M for Type V Fencing
4 Design
4.1 The type of fencing required is dependent upon operational, safety and security
requirements and shall be determined by the Proponent Organization and in
accordance with Standard Drawing AB-036677.
4.2 The use of reclaimed material is not permitted unless written approval is
obtained from the Proponent Organization.
4.3 Saudi Aramco Security Fencing Type I shall be used for all facilities where
security is of concern.
4.4 Saudi Aramco fencing shall be built according to the referenced Engineering
Standards and Standards Drawings (AB-036677, AA-036678, AB-036679, AC-
036680, AE-036881, AE-036882, AE-036883, AE-036884, and AE-036904.)
Page 3 of 7
Document Responsibility: Civil SAES-M-006
Issue Date: 30 November, 2003 Saudi Aramco Security
Next Planned Update: 1 February, 2008 and General Purpose Fencing
4.5 Galvanized fabric and hardware shall be used for all inland locations. Vinyl-
clad fabric, barbed wire, tension wire, tie wire, and gate infilling shall be
substituted at locations within 1.5 km of the sea (refer to Saudi Aramco
Materials System Specifications 12-SAMSS-021 and 12-SAMSS-022).
However, fencing that encloses or crosses over a ground grid and fencing
passing under overhead powerlines of 230 kV and above shall utilize galvanized
fabric and hardware regardless of location.
4.6 Saudi Aramco Security Fencing Type I shall have the bottom of the chain link
fabric tied to a continuous concrete anchor constructed according to Standard
Drawing AC-036680.
4.7 All concrete for footings and grade beams shall have a minimun compressive
strength of 27.6 MPa (4,000 psi) at 28 days and shall have type V sulphate
resisting cement. Placement and curing shall comply with SAES-Q-001,
Criteria for Design and Construction of Concrete Structures.
4.8 The concrete materail shall be in accordance with 09-SAMSS-097 "Ready-
Mixed Portland Cement Concrete".
4.9 Table 1 - Types of Saudi Aramco Fencing lists the different types of Saudi
Aramco fencing.
4.10 Table 2 - Applicable Gate Sizes lists the different sizes of gates applicable to
each type of Saudi Aramco fencing. Width opening is measured from inside to
inside of the gate posts. All gates are listed in the SAMS Catalog.
4.11 Total post length for all posts up to 102 mm O.D. shall be as specified in
Table 3 - Post Lengths (±12 mm). These lengths include 900 mm extension in
the footing.
Table 1 – Types of Saudi Aramco Fencing
Height of Brace Posts Barbed Wire
Fencing for Each Number of Continuous
Fencing Fabric Top Line Post Supporting Number of Concrete
Type (mm) Rail (1) Arms Standards Anchor
I 2400 Yes Yes 2 6 Yes
II 2400 Yes Yes 2 6 No
III 2400 No No 2 6 No
IV 2400 No No 1 3 No
V 2400 No No 0 0 No
Note: (1) Refer to paragraph 4.4
Page 4 of 7
Document Responsibility: Civil SAES-M-006
Issue Date: 30 November, 2003 Saudi Aramco Security
Next Planned Update: 1 February, 2008 and General Purpose Fencing
Table 2 – Applicable Gate Sizes
Walk Width Overall Gate Post
Gate or Opening Height Gate Frame Size O.D.
Fence Type Type Drive (mm) (mm) Extensions (mm)
I, II, III, IV, V A Walk 1200 2450 No 73
B Drive 4000 2800 Yes 102
I, II, III, IV C Drive 7300 2800 Yes 102
V D Drive 4000 2450 No 102
E Drive 7300 2450 No 102
Table 3 – Post Lengths
Length of Posts (mm)
Fence Type I II III IV V
Walk Gate 3400 3400 3400 3400 3400
Drive Gate 3900 3900 3900 3900 3400
Line 3400 3400 3400 3400 3400
Corner/End 3400 3400 3400 3400 3400
Brace 2900 2900 2900 2900 2900
5 Installation
5.1 Grounding
The fence shall be grounded in accordance with SAES-P-111.
5.2 Posts
5.2.1 All posts shall extend 900 mm into concrete footings as measured from
the ground surface. Where solid rock is encountered, posts shall extend
600 mm into concrete footings.
5.2.2 Footings for all posts shall extend 100 mm below the end of the post.
5.2.3 The post/foundation interface shall be treated as indicated on Standard
Drawing AC-036680, Footing Details.
5.2.4 If pre-cast fence post footings are used, backfill shall be compacted to
meet or exceed the existing soil density.
5.2.5 All line posts shall be equally spaced at intervals of not more than 3 m.
Page 5 of 7
Document Responsibility: Civil SAES-M-006
Issue Date: 30 November, 2003 Saudi Aramco Security
Next Planned Update: 1 February, 2008 and General Purpose Fencing
5.2.6 All posts except brace posts shall be installed in a vertical position,
plumb and in line.
5.2.7 Terminal posts (Corner, End, Gate or Tension) shall be installed at the
beginning and end and at a maximum of 90 m intervals of fence fabric
and at changes in vertical and horizontal alignments exceeding 22½°
deflection angle.
5.2.8 All posts shall be equipped with moisture excluding top caps or
extension arms.
5.3 Top Rail
The top rail (41 mm O.D. pipe) for Saudi Aramco Security Fencing Type I and
Saudi Aramco Type II Fencing shall be continuous except over drive gates. One
expansion coupling shall be used for every 30 m of rail.
5.4 Brace Posts
Brace posts shall be attached to all Saudi Aramco Security Fencing Type I and
Saudi Aramco Type II line posts at a point 1500 mm above ground level and
extend downward toward the inside of the fence at 45° in a vertical plane which
is perpendicular to the plane of the fence. For Types III, IV, and V Fencing,
brace posts shall be installed on line posts at 90 m centers of fencing runs.
5.5 Chain Link Fence
5.5.1 The fencing fabric for Saudi Aramco Security Fencing Type I and Saudi
Aramco Type II Fencing shall be attached to top rails by means of tie
wires spaced at intervals not exceeding 600 mm.
5.5.2 The fencing fabric shall be attached to the tension wire by means of tie
wires spaced at intervals not exceeding 300 mm. The tension wire shall
be attached to the line posts by tie wire wrapped around the post and
secured to the tension wire by 3 complete turns on each side of the post.
The fencing fabric shall be attached to all line posts by means of tie wire
spaced at intervals not exceeding 350 mm along each post.
5.6 Barbed Wire
Except on Type V Fencing, barbed wire shall be held in the extension arm slots
by means of lock wire. Holding the barbed wire in the slots by means of the
tension in the wire is not permitted. Barbed wire, where required, shall be
extended over walk gates.
Page 6 of 7
Document Responsibility: Civil SAES-M-006
Issue Date: 30 November, 2003 Saudi Aramco Security
Next Planned Update: 1 February, 2008 and General Purpose Fencing
5.7 Tension Wire
Tension wire shall be secured to terminal posts by means of a winding bracket.
5.8 Bracing in Plane of Fence
5.8.1 Each brace assembly shall consist of one top and one intermediate
compression member both of 41 mm O.D. pipe and one adjustable
diagonal tension rod of at least 10 mm diameter. For Saudi Aramco
Security Type I Fencing and Type II Fencing, the top rail is the top
compression member. Pipe used for the compression members shall be
of one piece without couplings in the bracing panel.
5.8.2 Gate and end posts shall be braced to the nearest line post with one
complete brace assembly.
5.8.3 Corner and tension posts shall be braced to the two nearest line posts
with one complete brace assembly to each line post.
5.9 General
When fully constructed the barbed wire, tension wire, fabric, and truss rods shall
be taut.
Revision Summary
29 January, 2003 Revised the "Next Planned Update". Reaffirmed the contents of the document, and
reissued with no other changes.
30 November, 2003 Editorial revision.
Page 7 of 7