Shen Zhen SDG Information Co.
, Ltd
Factory Test
Product Name: Stranded loose tube optical fibre cables
For Outdoor Application for Telecommunication
Model Specifications: GYTY53-24B1
Client Name: Shenzhen SDG Information Co.,Ltd
Sample No. :
Kind of Test: Factory Test
Place of Test: Shenzhen SDG Information Co.,Ltd
Date of Issue: 27th May 2015
1
Shen Zhen SDG Information Co., Ltd
Test Report
GYTY53 Modal GYTY53-24B1
Name
Sample No. Length 3500m
Ambient
Kind of Test Factory Test 25℃
Temperature
Standard IEC 60793 and IEC 60794
After the test,its test result satisfies the International Standard
IEC 60793 and IEC 60794
Test Result
Date Issue: 27th May 2015
Prepared by: Verifier: Approver:
Date: Date: Date :
2
Shen Zhen SDG Information Co., Ltd
Main Test Equipment:
NO. Name Type Management Code Valid Period
1 PMD Tester FTB-500 592707 2016.3.05
2 Dispersion Tester PK2800 2800-IK-Z8G 2016.3.05
3 OTDR MT9083 6200897541 2015.11.30
Electronic Digital
4 0-150mm/0.01mm C1104185202 2015.11.30
Caliper
5 Integrated test PK2200 54322522 2016.3.05
Geometric parameters
6 FGM-5 12B505 2016.3.05
Tester
7 Temperature Test Box HWT12-70W MY41015103 2016.3.05
Force Measuring
8 TS-3t 960411 2016.3.05
Sensor
9 Crush Tester GYB-4 20121202 2016.3.05
10 Bending Tester GWQ-4 20121204 2016.3.05
3
Shen Zhen SDG Information Co., Ltd
1、Mechanical&Environmental Properties
Item Test Item Technical Requirement Test result Conclusion
long-term load: 1000N;
short-term load: 3000N; Additional attenuation≤ 0.03dB,
1.1 Tensile Qualified
can't see crack in outer sheath
additional attenuation≤0.05dB, can't
see crack in outer sheath
Crush strength-long: 1000N;
Fibre additional attenuation ≤
1.2 Crush Crush strength-short: 3000N; 0.01dB, can't see crack in outer Qualified
Fibre additional attenuation≤0.05dB, sheath
can't see crack in outer sheath
Radius:
short term,10*cable diameter,
long term,20*cable diameter, Fibre additional attenuation≤
1.3 Bending 0.01dB, can't see crack in outer Qualified
Angle: ±90°;Bending times: 30 times, sheath after test.
Fibre additional attenuation≤0.05dB,
can't see crack in outer sheath after
test.
4
Shen Zhen SDG Information Co., Ltd
Test Technical
Item Test result Conclusion
Item Requirement
Cycle 1 Cycle 2
1310 1550 1310 1550
1 -0.003 -0.001 -0.033 -0.024
2 -0.004 -0.004 -0.014 -0.020
3 -0.001 -0.025 -0.013 -0.021
4 0.000 -0.002 -0.011 -0.013
5 -0.004 -0.001 -0.010 -0.014
6 0.003 -0.003 -0.007 -0.011
-40
℃ 7 -0.006 0.009 -0.009 0.002
Temperature : 8 0.005 0.010 -0.004 -0.016
-40℃ to +70℃ 9 -0.000 -0.001 -0.023 -0.016
Frequency:2 10 0.006 0.007 -0.010 -0.006
Temper- Soaking time: 11 -0.002 -0.020 0.001 -0.003
1.4 ature Qualified
Cycle no less than 12 hours 12 -0.003 0.008 -0.005 -0.011
Fibre additional
1 -0.007 -0.016 -0.009 0.012
attenuation compared
to 20℃ attenuation 2 0.004 -0.003 0.008 0.013
should be no more than
0.05dB/km 3 0.013 -0.003 0.007 -0.011
4 -0.014 -0.003 -0.007 0.015
5 -0.008 -0.033 0.018 0.013
6 -0.003 -0.011 0.009 0.003
+70
℃ 7 0.006 0.000 0.007 -0.014
8 -0.004 -0.015 -0.007 0.013
9 -0.004 -0.020 0.008 -0.010
10 0.002 -0.004 0.009 0.012
11 0.000 0.008 -0.008 0.013
12 0.013 0.018 0.010 -0.012
5
Shen Zhen SDG Information Co., Ltd
2、Fiber Properties
Item Test item Unit Requirement Test result Conclusion
Fiber DCL Fiber DCL
Cladding Diameter B1: 1 125.05 4 124.93
2.1 µm Qualified
(DCL) 125±1.0
2 125.19 5 125.05
3 124.81 6 125.03
Fiber Fiber
B1: 1 251.57 4 250.15
2.2 Coating Diameter µm Qualified
245±10 2 252.07 5 252.28
3 251.67 6 251.37
Fiber OCL Fiber OCL
Cladding ellipticity 1 0.2 4 0.2
2.3 % B1:<1.0 Qualified
(OCL) 2 0.3 5 0.1
3 0.4 6 0.5
Fiber MFD Fiber MFD
Model Field 1 9.181 4 9.215
2.4 Diameter @1310nm µm B1: 9.2±0.5 Qualified
(MFD) 2 9.175 5 9.197
3 9.203 6 9.175
Fiber Dcl/core Fiber Dcl/core
Concentricity of clad 1 0.16 4 0.15
2.5 µm B1:0.8 Qualified
to core error 2 0.17 5 0.11
3 0.18 6 0.13
Fiber cc Fiber cc
Cutoff wavelength B1: 1 1215 4 1184
2.6 nm Qualified
( cc) cc<1260 2 1197 5 1187
3 1210 6 1214
Fiber 0 Fiber 0
B1: 1 1308.14 4 1312.47
Zero dispersion
2.7
wavelength 0
nm 13000 Qualified
1324 2 1309.85 5 1310.84
3 1311.34 6 1310.07
6
Shen Zhen SDG Information Co., Ltd
Item Test item Unit Requirement Test result Conclusion
Fiber S0 Fiber S0
1 0.0875 4 0.0884
Zero dispersion
2.8
slope S0
ps/nm2km B1:0.092 Qualified
2 0.0878 5 0.0887
3 0.0885 6 0.0878
Fiber Dmax Fiber Dmax
Chromatic
Dispersion @ 1 2.54 4 2.27
2.9
12851330nm
ps/nmkm B1:3.5 Qualified
2 2.35 5 2.37
3 2.15 6 2.45
Fiber D1550 Fiber D1550
Chromatic 1 16.51 4 16.54
2.10 Dispersion ps/nmkm B1:18 Qualified
@1550nm 2 16.25 5 16.35
3 16.15 6 16.88
Fiber α1310 Fiber α1310
1 0.327 4 0.332
Attenuation
2.11
@1310nm
dB/km B1:0.36 Qualified
2 0.329 5 0.334
3 0.334 6 0.338
Fiber α1550 Fiber α1550
1 0.195 4 0.197
Attenuation
2.12 @1550nm
dB/km B1:0.22 Qualified
2 0.188 5 0.192
3 0.192 6 0.195
7
Shen Zhen SDG Information Co., Ltd
3. Physical & Dimensions Properties
Item Test Item Unit Sample Test result Conclusion
3.1 No. Of Fiber - 24 Qualified
3.2 No Of Loose Tubes - 4 Qualified
3.3 Type Of Fibre - G.652D Qualified
3.4 Central Strength Member - FRP Qualified
Blue、Orange、Green、 Brown、
3.5 Sequence Of Loose Tubes - Qualified
Filler-1、 Filler-2
Blue、Orange、 Green、Brown、
3.6 Colour Of Fibre - Qualified
Gray、 White
Inner & Outer
3.7 - PE Qualified
Sheath Material
3.8 Outer Cable Diameter mm 13.00 Qualified
3.9 Cable Weight kg/km 193 Qualified
3.10 Printing On Cable - As Per Customer Requrement Qualified
3.11 Drum Length M 3500 Qualified
Firmado electrónicamente por:
EDUARDO ERNESTO
ROJAS BLANCO