Certificate No:
TAE0000333
TYPE APPROVAL CERTIFICATE
This is to certify:
That the Electric Power Cable
with type designation(s)
BFOU P105 & BFCU & BFMU 0,6/1 kV
Issued to
Seoul Electric Wire Co., Ltd.
Eumseong-gun, Chungcheongbuk-do, Republic of Korea
is found to comply with
DNV GL rules for classification – Ships, offshore units, and high speed and light craft
IEC 60092-353 (2016-09)
Application :
General power and lighting, Control, Fire resistance, Flame retardant Cat.A, Halogen free, Low
smoke, Cold bend(-40°C) Cold impact(-35°C)
Product(s) approved by this certificate is/are accepted for installation on all vessels classed
by DNV GL.
Rated voltage (kV) 0,6/1
Temp. class (°C)    90
Issued at Busan on 2018-08-14
This Certificate is valid until 2022-12-31.                                                               for DNV GL
DNV GL local station: Seoul
Approval Engineer: Eun Sook Kim
                                                                                                 Andreas Kristoffersen
                                                                                                      Head of Section
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
          Form code: TA 251                           Revision: 2016-12                                  www.dnvgl.com                    Page 1 of 3
                                                                  © DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.
                                                                 Job Id:         262.1-006082-3
                                                                 Certificate No: TAE0000333
Product description
Type:            BFOU P105 & BFCU & BFMU 0,6/1 kV
Construction:
Conductors:            Tin-coated annealed copper Class 2 or Class 5
Core insulation:       Mica/glass tape + EPR
Inner covering:        Halogen free compound
Metal covering:        Tinned copper wire braid (O) or Galvanized steel wire braid (C) or
                       Copper alloy wire braid (M)
Outer sheath:          SHF2 (no marking) or SHF Mud (E or M)
  Number of cores        Conductor cross-section (mm2)
1C                     1 ~ 630
2C, 3C                 1 ~ 300
2C+E, 3C+E             1 ~ 16
4C                     1 ~ 240
5~44C                  1.0, 1.5, 2.5
2C+E, 3C+E, 4C+E       25 ~ 240 / 16 ~ 120
Application/Limitation
This type of cable is fire resistant in accordance with IEC Publication 60331.
The requirements of SOLAS Chapter II-1 Part D Reg. 45.5.2 to limit Fire Propagation along Bunches of
Cables or Wires are fulfilled without any additional measures.
Type Approval documentation
Tests carried out
 Standard             Release         General description                             Limitation
 IEC 60092-350        2014-08         General construction and test methods of
                                      power, control and instrumentation cables
                                      for shipboard and offshore applications
 IEC 60092-353        2016-09         Power cables for rated voltages 1 kV and 3
                                      kV
 IEC 60092-360        2014-04         Insulating and sheathing materials for
                                      shipboard and offshore units, power, control,
                                      instrumentation, telecommunication cables
 IEC 60331-1/-2       2009-05         Fire resistance / Circuit integrity – Test      120 min.
                                      method for fire with shock at temperature of
                                      at least 830ºC for cables rated up to and
                                      including 0,6/1 kV
 IEC 60332-1          2015-07         Test for vertical flame propagation for a
                                      single insulated wire or cable
 IEC 60332-3-22       2009-02         Tests on electric and optical fibre cables      Bunch test
                                      under fire conditions - Part 3-22: Test for     Category A
                                      vertical flame spread of vertically-mounted
                                      bunched wires or cables - Category A
 IEC 60684-2          2011-08         Flexible insulating sleeving – Part 2:          Fluorine content
                                      Methods of test.                                <0.1%
 IEC 60754-1          2014-05         Test on gases evolved during combustion of      Low Halogen
                                      materials from cables – Determination of the    <0,5%
                                      amount of halogen acid gas
 IEC 60754-2          2014-05         Test on gases evolved during combustion of      Halogen free
                                      materials from cables – Determination of the    ≥4,3pH, ≤10µS/mm
                                      degree of acidity of gases evolved during the
                                      combustion of materials taken from electric
                                      cables by measuring pH and condctivity
 IEC 61034-1/-2       2005-04         Measurement of smoke density of cables          Low smoke
                                      burning under defined conditions –              >60%
Form code: TA 251         Revision: 2016-12                          www.dnvgl.com                 Page 2 of 3
                                                                  Job Id:         262.1-006082-3
                                                                  Certificate No: TAE0000333
 Standard              Release        General description                             Limitation
                                      Test apparatus, procedure and requirements
 CSA C22.2             2009-09        5.11 Flexibility at any specified temperature   Cold bend (-40°C)
 No.0.3-09                            test
 CSA C22.2             2009-09        5.12 Abnormal low temperature - impact          Cold impact (-35°C)
 No.0.3-09
 UL1581                2001           UV resistance
 NEK 606               2016           Cables for offshore installations – Technical   Oil & Mud resistant –
                                      specification                                   No marking: Cat. a
                                                                                      E marking: Cat. b
                                                                                      M marking: Cat. c
Marking of product
SEOUL ELECTRIC WIRE – 0,6/1 kV – Type designation – Size – IEC60332-3A – IEC 60331(120) – Year of
manufacture – Length – (NEK 606) – (E or M)
Periodical assessment
The scope of the retention/renewal survey is to verify that the conditions stipulated for the Type
Approval Certificate are complied with and that no alterations are made to the design and/or the
material of product.
The main elements of the survey are:
  Inspection on factory samples, selected at random from the production line (where practicable)
  Check of results from Production Sample Tests (PST) and Routine tests (RT) (if not available, PST
   and RT are to be carried out)
  Review of type approval documentation
  Review of possible changes in design, material and performance
  Ensuring traceability between manufacturer’s product type marking and Type Approval Certificate.
Periodical assessment is to be performed after 2 years and after 3.5 years. A renewal assessment will be
performed at renewal of the certificate.
END OF CERTIFICATE
Form code: TA 251         Revision: 2016-12                           www.dnvgl.com                  Page 3 of 3