Battery Range Summary

PowerSafe® Vb batteries are vented lead-acid batteries designed for


industrial applications in power supply with high safety requirements.
These single cells are qualified for both short duration discharges
with high current and long duration discharges with low current.
The main areas of application are DC power supply systems in
power stations and substations, UPS systems, industrial systems
and emergency power supply systems. They can also be used for
engine starting and for energy storage in solar power systems.

The special rod plate design of PowerSafe Vb batteries offers a high


energy density and a very long life time in one unique design.
This gives better performance and can minimise the use of valuable
floor space. A rigid earthquake-proof cell allied with the unique
PowerSafe Vb safety pole terminals makes this a superior battery
design. A very long topping up interval minimises service
requirements to complete the package.

Features and Benefits


Capacity range: 275Ah – 2400Ah
Single cells, 2V nominal voltage
25 year design life in standby applications (20ºC) due to proven
rod plate technology and safety pole
Water topping up interval about 5 years in standby operation
mode at 20°C
High cycling capability in energy storage systems
Rigid cell design, earthquake-proof

RESERVE
Visit us at www.enersys.com POWER AS-PS-VBc-RS-001 - August 2016
Construction • Connectors - solid copper connector • If accommodated in battery rooms or
• Positive electrode - rod plate with low (30mm x 5-10mm) insulated, bolted type, cabinets, the safety provisions specified in
antimony lead alloy. Special hanging plate voltage measurement possible EN 50272-2, IEC 62485-2 and national
design allows for growth giving superior • Vent Plugs - flame arrestor safety vent plugs regulations must be applied
aging behaviour as standard, ceramic funnel plugs available • Recommended range of operation:
• Negative electrode - grid plate with lead alloy as option +10°C to +30°C
(maximum operating range: -10ºC to +45ºC)
• Separation - microporous separator,
combined with fleece pocket for the positive Installation & Operation
electrode • Float charge voltage: Standards
• Casing material - styrene-acrylonitrile (SAN), 2.23Vpc at 20°C • Conforms to IEC 60896-11
impact resistant, transparent, with electrolyte • Suitable for all types of installation • The management systems governing the
level indication i.e. Max / Min manufacture of PowerSafe® Vb single cells
• Small floor area required for installation due
• Electrolyte - dilute sulphuric acid, to high energy density are ISO 9001:2008 and ISO 14001:2004
density = 1.24 kg/l certified
• For use in earthquake zones special
• Terminal Design - leak-proof safety pole with approved racks are available
solid brass insert and M10 stainless steel bolt

General Specifications
Nominal Capacity (Ah) Nominal Dimensions (mm)
Nominal 10 hr rate 8 hr rate Typical Electrolyte Volume Internal
Cell Voltage to 1.80Vpc to 1.75Vpc Weight S.G. = 1.240 Short Circuit Resistance
Type (V) @ 20°C @ 77°F Length Width Height* (kg) (Litres) Current (A) (mΩ)
Vb 2305 2 275 275 122 266 440 30.1 7.0 4195 0.50
Vb 2306 2 330 330 122 266 440 32.2 6.7 5034 0.41
Vb 2307+ 2 385 385 122 266 440 34.3 6.5 5873 0.35
Vb 2308 2 440 440 188 266 440 45.9 11.7 6712 0.31
Vb 2309 2 495 495 188 266 440 48.0 11.5 7551 0.28
Vb 2310+ 2 550 550 188 266 440 50.4 11.2 8390 0.25
Vb 2311+ 2 605 605 188 2665 440 52.9 10.8 9229 0.23
Vb 2312 2 660 660 233 266 440 61.0 14.4 10068 0.21
Vb 2313+ 2 715 715 233 266 440 63.3 14.1 10907 0.19
Vb 2314+ 2 770 770 233 266 440 65.4 13.8 11746 0.18
Vb 2408 2 916 916 374 213 550 98.1 23.4 10085 0.21
Vb 2409 2 1030 1030 374 213 550 102 22.7 11346 0.18
Vb 2410 2 1140 1140 374 213 550 108 22.0 12606 0.16
Vb 2411+ 2 1250 1250 374 213 550 112 21.4 13867 0.15
Vb 2412 2 1370 1370 374 298 550 141 33.1 15128 0.14
Vb 2413 2 1480 1480 374 298 550 146 32.4 16388 0.13
Vb 2414 2 1600 1600 374 298 550 150 31.7 17649 0.12
Vb 2415 2 1710 1710 374 298 550 155 31.0 18909 0.11
Vb 2416+ 2 1830 1830 374 298 550 160 30.3 20170 0.10
Vb 2417 2 1940 1940 374 383 550 190 43.1 21431 0.10
Vb 2418 2 2060 2060 374 383 550 195 42.3 22691 0.09
Vb 2419 2 2170 2170 374 383 550 199 41.8 23952 0.09
Vb 2420 2 2290 2290 374 383 550 204 41.1 25213 0.08
Vb 2421+ 2 2400 2400 374 383 550 209 40.4 26473 0.08
The electrical values shown in the table relate to loadings from a fully charged condition at ambient temperature of 20°C (unless otherwise specified).
*Height includes connector.

H H H
H

L 10
L 5 L 10
L 10

W W
W W

Vb 2305 . . .Vb 2314+ Vb 2408 . . .Vb 2411+ Vb 2412 . . .Vb 2416+ Vb 2417 . . .Vb 2421+

EnerSys World Headquarters 2366 Bernville Road, Reading, PA 19605, USA Tel: +1-610-208-1991 / +1-800-538-3627
EnerSys EMEA EH Europe GmbH, Baarerstrasse 18, 6300 Zug, Switzerland Tel: +41 44 215 74 10
EnerSys Asia 152 Beach Road, Gateway East Building #11-03, Singapore 189721 Tel: +65 6508 1780
© 2016 EnerSys. All rights reserved.
Trademarks and logos are the property of EnerSys and its affiliates, except ISO, which is not the property of EnerSys.
Subject to revisions without prior notice. E.&O.E.
www.enersys.com AS-PS-VBc-RS-001 - August 2016

You might also like