FACTORY AUTOMATION Sensor systems 2

AS-Interface
Edition 2005/2006
AS-Interface - References
AS-Interface has made a breakthrough on a wide front in automotive tech-
nology. And the examples given below of typical applications illustrate how
AS-Interface is also employed by well-known manufacturers in many other
branches of industry.

Automotive industry:
The floor and overhead suspended conveyor system in the new Rüssels-
heim plant of OPEL AG has been completely automated using AS-Inter-
face. Over one hundred AS-Interface gateways and over one thousand AS-
Interface modules are used to process the signals from several thousand
sensors and encoders. A remarkable feature of this plant is the through-
going production line without buffer systems, requiring the AS-Interface net-
work to be constructed in segments, using sliding contacts. The overall
length of this system is well over one kilometre. The transfer and assign-
ment functions via the sliding contacts demonstrate once again the robust-
ness and reliability of AS-Interface.

Chemical and process technology:


Paint manufacture and the subsequent filling of the products is the core
business of the Herberts Lacke Company. The demands of the automated
production plant concept include the provision of safeguards in the poten-
tially explosive areas. AS-Interface modules with ATEX approval for Zone 1
are daily proving their value in these critical applications.

Storage and mechanical handling:


Plant sections involving logic networks are simply controlled via AS-Inter-
face. Thanks to the comprehensive diagnostic functions, problems can be
quickly and precisely located, even in extensive systems, leading to the re-
duction of downtime and rationalisation of plant servicing.
These attributes prompted Viastore Systems GmbH to select AS-Interface
in numerous high-bay racking stores projects. In another application in
2003, Roche Diagnostik collaborated with Aberle Steuerungstechnik GmbH
in pallet and container handling technology featuring AS-Interface.

Plant construction:
As a renowned constructor of filling plant, Krones has for some time suc-
cessfully incorporated the AS-Interface concept into its projects. This has
allowed decentralised plant components to be controlled on a modular ba-
sis and networked together with ease. Here, high quality, long life and great
flexibility are the attractive AS-Interface features.

Food and beverage industry:


In breweries - and as here, in the dispensing of drinks - Feige GmbH uses
AS-Interface to control flows via the open/close operation of valves. Well-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

proven solutions are available for the open structure, as are pcb solutions
for box installation and also integrated solutions for solenoid valves.

Component manufacture:
In order to reduce the amount of cabling required and to provide adequate
flexibility for alternating production lines, AS-Interface is frequently em-
ployed to control the handling sequences, as illustrated here on an SMD as-
sembly plant. As a rule the Emergency-Stop buttons are also integrated into
the AS-Interface Safety at Work concept, so as to avoid dual cabling.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
6 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Table of contents
1 Introduction .........................................................................................................................8
1.1 What is AS-Interface? ........................................................................................................................................8
1.2 The decisive advantages of AS-Interface ..........................................................................................................8
1.3 Components in the AS-Interface system .........................................................................................................11
1.4 AS-Interface specification 2.1 ..........................................................................................................................16
1.5 Configuration and installation of a system with AS-Interface in 4 steps ..........................................................20

2 Masters and Gateways .....................................................................................................23


2.1 Master ..............................................................................................................................................................24
2.2 Gateways .........................................................................................................................................................24
2.3 Programming with AS-i Control Tools ..............................................................................................................24

3 Power Supplies, Power Extenders and Repeaters.........................................................57


3.1 Overview of power supplies, power extenders, and repeaters ........................................................................59

4 AS-Interface - Safety at work ...........................................................................................81


4.1 The safety concept...........................................................................................................................................82
4.2 The advantages ...............................................................................................................................................82
4.3 Safety monitor..................................................................................................................................................83
4.4 Safe slaves ......................................................................................................................................................84
4.5 The ASIMON configuration software ...............................................................................................................84
4.6 Overivew of available AS-Interface Safety at Work products ..........................................................................85

5 Coupling modules...........................................................................................................107
5.1 Switch cabinet and junction box modules ......................................................................................................108
5.2 Field modules.................................................................................................................................................150
5.3 Analogue modules .........................................................................................................................................193
5.4 Ex Modules ....................................................................................................................................................207
5.5 AirBox (Pneumatic Module) ...........................................................................................................................216
5.6 Display and control modules..........................................................................................................................221
5.7 Printed circuit board module ..........................................................................................................................221
5.8 Engine starter ................................................................................................................................................221

6 Inductive AS-Interface Sensors .....................................................................................237

7 Photoelectric AS-Interface Sensors ..............................................................................255

8 AS-Interface Rotary Encoder .........................................................................................273

9 Accessories.....................................................................................................................307

10 Mating connectors and cable.........................................................................................337


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

11 AS-Interface Training Kit ................................................................................................345

12 Additional Information....................................................................................................346
12.1 Glossary.........................................................................................................................................................346
12.2 AS-Interface type codes (without modules and accessories) ........................................................................348
12.3 Type code for I/O modules / analogue modules ............................................................................................349
12.4 Type code for cable sockets ..........................................................................................................................350
12.5 Type codes for connector cables....................................................................................................................350
12.6 Pepperl+Fuchs GmbH worldwide ..................................................................................................................352

13 Alphabetical list of types................................................................................................358


Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 7
AS-Interface - Introduction

1 Introduction
1.1 What is AS-Interface?
The Actuator-Sensor Interface (AS-Interface) is the replacement for con-
ventional wiring technology on the sensor-actuator level.
AS-Interface ensures secure, extremely EMC resistant data transmission,
minimises installation time and costs, includes a diagnostic function and de-
tects short circuits and other conditions, reduces maintenance costs, ena-
bles the simple decentralisation of control processes, increases the trans-
parency of a system, makes any kind of upgrade particularly simple and
flexible, and guarantees high availability.
AS-Interface is not a proprietary system, but rather an open standard which
is available on the market from many manufacturers in a wide range of ver-
sions.

1.2 The decisive advantages of AS-Interface


The Actuator-Sensor-Interface (AS-Interface) is optimised for the reliable
transfer of small volumes of data under harsh industrial conditions and for
economic reasons it has become the tried and tested standard for the net-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

working of sensors and actuators in many applications.

In conventional wiring two cores per sensor and actuator are typically re-
quired for the power supply and a further core for the signal or control cable.
The power supply, for example, can be laid in parallel via splitter boxes, but
the input and output signals must be looped via distribution devices and laid
to PLC cards. This leads to high costs for the method of connection/distri-
bution, involves much time on installation and, in addition, the wiring must
be documented in detail.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
8 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
In comparison, AS-Interface offers the following advantag-
es:
• Two-core cable for data and power transfer to all devices.
• Connection using the insulation penetration technique for I/O stations
saves time, since the operations involving the stripping of insulation and
the application of cable sleeves are eliminated.
• In the PLCs the I/O assemblies are replaced by the AS-Interface master
and the assignment is no longer carried out by fixed addressing of the I/O
cards, but by free assignment via the master.
• Diagnostic options via the AS-Interface enable faults to be quickly elimi-
nated and down time reduced.
• Ground faults and duplicate addressing can be detected and displayed.
• If "intelligent" sensors are employed, the display of stability control, re-
mote parameter assignment, mode of operation reversal and standby in-
dication functions can be used. The function diagnosis can decisively
increase plant availability.
• By using AS-Interface masters with integrated PLC functionality, control
processes can be stored as programs in the master and self-standing
PLCs can be dispensed with completely. This allows response times of
only a few milliseconds to be achieved.
• Due to the reduced requirement for wiring, less cable ducting is required.
• Costs are also reduced because of the space saved in the control cabinet
due to the elimination of I/O assemblies.
• The free topology makes system planning and installation particularly
simple, so that it can be extended at any time.

Actuator Sensor Interface Conventional Decentralized I/O assemblies

PLC PLC PLC

I/O assembly

e.g. INTERBUS-S
PROFIBUS DP

I/O assembly I/O assembly

24 V DC 24 V DC 24 V DC

These AS-Interface advantages lead to cost savings in planning, com-


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

missioning and maintenance.

By using interface modules up to 248 binary sensors and 186 binary actu-
ators can be operated on a single AS-Interface network. The following lim-
iting values apply to a fully implemented system for both AS-Interface spec-
ifications:
• Master/Gateway - Specification 2.0:
max. 124 binary sensors and 124 binary actuators.
• Master/Gateway - Specification 2.1:
max. 248 binary sensors and 186 binary actuators.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 9
AS-Interface - Introduction
Data Protection
The interference resistance of data transmission is an important parameter
for the networking of sensors and actuators in an industrial environment.
Due to the special type of coding (Manchester Code APM, Alternating Pulse
Modulation) and the continual monitoring of signal quality, AS-Interface
achieves such a high level of data protection, that the system is also suit-
able for safety applications.
This is not affected by the absence of screening on the transfer cable. Tests
on a welding robot and a galvanising plant showed that the AS-Interface
system was not affected by these levels of external interference. This is
possible due to the symmetrical signal transfer, which filters out interfer-
ence.

Network hierarchy and topology


Master AS-Interface is designed for the lowest level of the automation hierarchy
and offers a simple, safe and fast transfer at an optimum cost/effectiveness
ratio. The system topology can take the form of a line, star, tree, or ring
structure. For information which is not time-critical and for the achievement
of longer transfer paths, AS-Interface can be connected via gateways to
higher level systems such as PROFIBUS, InterBus, EtherNet TCP/IP, De-
Master
viceNet, Modbus, Modbus+, CCLink, CANopen, etc. AS-Interface masters
with serial RS 232 interfaces and integrated PLC functionality provide a dis-
tributed stand-alone solution. In this way the control system is unloaded
and, in addition, cycle times of, for example, 2 ms are achieveable when the
AS-Interface network is not fully populated. This solution is directly aligned
with the trend towards the decentralised construction of control units. The
advantages are:
Master

• simpler and faster expansion possibilities and also the commissioning of


sub-domains,
• shorter cable connections and less data communication on the higher-
level field bus,
• reduction of down time due to the autonomously operating sub-domains
and
• shorter and clearer programs.

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
10 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
1.3 Components in the AS-Interface system
Products from Pepperl+Fuchs are certified by independent AS-Interface
testing authorities. This ensures that the products satisfy the AS-Interface
specification and can be operated without problem in a system together with
other certificated AS-Interface products, including those from other manu-
facturers. This is indicated by the shadowed logo on the data sheets.

Masters and Gateways


The core of the AS-Interface system is the Master (serial connection via
RS 232) and the Gateway (master with an interface to the commonly used
field buses). Earlier programming by PC or PLC can continue to be utilised,
for example, with an S7-400 with a standard I/O data range, since AS-Inter-
face behaves as an I/O card. The devices control and monitor the data ex-
K5 change with the modules and AS-Interface sensors/actuators on the Mas-
ter-Slave principle. However, as seen from the field bus, the gateway be-
haves as a slave or station node, with typically more than 32 bytes of in-
put/output data and also with additional analogue channels and manage-
ment channels.
Master/Gateways are available in the form of plug-in cards for a PC, as con-
trol cabinet devices and as field devices. The masters/gateways include a
PCI
diagnostic function with the following monitoring functions:
• Configuration errors: Deviation between existing slaves and configured
addresses,
• Peripheral faults: Loss of function of one or more slaves,
• Communication faults: Incorrect transfer of several messages,
• Detection and display of duplicate addressing and ground faults (on K20
series),
• Safety diagnosis: Separate presentation of the safe slaves and display of
K20 the diagnostic function of the monitor.
AS-Interface power packs (2 A to 8 A, with 30.5 V and data decoupling)
are used for the power supply. Repeaters and Power Extenders allow the
power supply to be decentralised and cable length to be extended to over
100 m. The repeater galvanically isolates the primary and secondary sides,
in order to provide a reduced probability of failure in the case of a short cir-
cuit. A number of repeaters can be operated in a star formation, their
G4 number being limited only by the input resistance at the AS-Interface. How-
ever, it is only possible to operate a maximum of 2 repeaters in series. To-
gether with the repeater, an AS-Interface power supply is required for the
power supply of the other AS-Interface circuit.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

KF

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 11
AS-Interface - Introduction
AS-Interface slaves
Intelligent sensors/actuators
Either "intelligent" sensors/actuators with integrated AS-Interface chip, or
modules, are connected to the masters/gateways. Pepperl+Fuchs offers a
wide range of "intelligent" sensors.

VariKont L
RL28 Modules
Modules are AS-Interface stations to which standard sensors/actuators can
be connected. AS-Interface modules are available as a control cabinet so-
lution and as field modules with protection to IP67. Analogue values with up
to 16 bits can be automatically transferred to the higher level field bus via
G6 analogue modules within a max. of 35 ms.
The control cabinet modules in the KF and KF2 series are 20 mm or
40 mm (4EA modules) wide and offer plug-in terminals as well as power rail
connections for fast, simple installation in the control cabinet. These KF
modules are only available as standard slaves in specification 2.0. The
newer version in the KE series is available as an A/B slave according to
specification 2.1.
The terminal housing module in the K3 series is flat (39 mm) and thus tai-
lored to terminal housing requirements. The outputs are supplied externally
G2 and 3-wire sensors can also be connected. The KE1 series, which is only
50 mm high and 22.5 mm wide, offers connections for up to 4 two-wire in-
puts and 2 externally-supplied electronic outputs.
In the case of the field modules the G2 series is available with a plug-in
connection via M12, the G6 series with a plug-in connection via M8 and the
G4 series with cable gland and cage-clamp terminals in different housing
sizes.
Connection of the G2 modules is achieved directly by attaching the flat AS-
Interface cable in the respective base portion. In the G4 series it is possible
to make the AS-Interface connection via round cable. Series G6 is connect-
ed via a 4-pin M12 plug connector 4 (AS-Interface and 24 V auxiliary pow-
G4 er).
Analogue modules for switching cabinet and field use transmit analogue
input and output values for current and voltage as well as the analogue val-
ues from PT100 thermocouples without additional programming. In this
case it is necessary to use a master/gateway to Specification 2.1.
G5 series modules are in the device category (1)2G and are therefore ap-
proved for hazardous areas in Zone 1 in accordance with ATEX. The AS-
Interface cable is therefore installed in increased safety and the connection
is carried out in accordance with EN 50019. The module electronics are en-
capsulated and intrinsically safe inputs and outputs are available. NAMUR
G5 sensors in accordance with the requirements of IEC 60947-5-6 (DIN 19234,
NAMUR) can be connected to the inputs.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Safe modules are available in the G4, G2 and KE1 versions for field and
junction box or control cabinets. The devices are TÜV-certified according to
EN 954-1 and IEC 61508.
Further information can be found in the chapters on the modules.

KE1

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
12 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
AS-Interface - Safety at Work
- for safety-relevant applications
Safety-relevant components, such as emergency-stop buttons, safety light
grids and safety door locking mechanisms, can be integrated, based on the
identical technology and protocol. This only requires the installation of a
safety monitor and safe slaves in the network. Mixed operation of safe
and non-safe AS-Interface slaves is possible without problem. The monitor
has the function of monitoring the data communication on the AS-Interface
cable.
The safe slaves are used to transfer dynamic code sequences (8 x 4 bit da-
ta sequence), which are stored in each slave. These are "learned" during
the installation of the monitor. During operation, the monitor compares the
target and actual sequences on each cycle. If the alarm code "0000“ is
transmitted or a departure from the set sequence is established (e. g. due
to the failure of a device or a communication fault), the safety monitor
switches off safely within 40 ms. Switch-on again takes 100 ms. Up to two
shut-off circuits can be implemented per monitor.
The available slaves are safe field and control cabinet modules and an
Emergency-Stop button with an integrated AS-Interface chip.
Bus communication and the data protocol have been evaluated as safe by
the BIA and the technology has been certified by TÜV. According to
EN 954-1, the maximum safety category 4 is reached, and can be used for
stop category 0 (immediate power-off) and 1 (controlled power-off). In ac-
cordance with IEC 61508 approval, up to SIL 3 can be attained.

Hand-held and Software Tools


AS-Interface slaves from Pepperl+Fuchs are usually addressed using a
VBP-HH1 hand-held programming device over an addressing connector.
With the hand-held device, the following can be performed very quickly and
simply on-site:
• Isolation of the AS-Interface slave from the AS-Interface network,
• power supply of the AS-Interface via the hand-held device,
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

VBP-HH1 • address assignment for the AS-Interface slave,


• setting of outputs for function testing, even without PLC.
Separate disconnection of the master in the control cabinet or modification
of the AS-Interface power supply is not necessary.
With the hand-held, an entire AS-Interface network can also be addressed
through the AS-Interface cable if the master is inactive.
Easy-to-use software tools are available for system parameter assignment
using a PC. The AS-Interface control tools render parameter assignment a
very simple procedure and the ASIMON software is used to assign param-
Software
eters to the safety-related components.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 13
AS-Interface - Introduction
AS-Interface installation
If AS-Interface modules are used in the control cabinet or junction boxes,
connection via power rail is particularly advantageous.
Flat cable
When using AS-Interface in the field, the greatest advantages are realised
when flat cable is used. However, a 2-core, unscreened standard round ca-
ble with 1.5 mm2 cross section (for example, H05VV-F2x1,5) can be used.
Flat cable Due to the form of the flat cable, polarity reversal is impossible, and using
insulation penetration connection, slaves can be connected in seconds. For
this purpose, the flat cable is laid in two cable trays in the lower part of the
module and the upper part of the module is then positioned on it and
screwed down. This ensures both strain relief and also a secure contact via
two contact blades per core.
A 24 V auxiliary power supply is necessary only for very high-powered ac-
tuators, and can be supplied via a black flat cable which is laid parallel to
the yellow AS-Interface flat cable.
Installation
The AS-Interface cable is symmetrical, that is, neither of the two cores may
conventional be earthed. A branch can be made at any point (arbitrary topology), on the
end of which no termination resistor is necessary.
The total length of the AS-Interface network can be extended from 100 m
by an additional 100 m using repeaters.
Power supply is generally incorporated using the AS-Interface power at any
point in the AS-Interface network. For slaves with particularly large power
requirements, it makes sense to put the power supply nearby, to keep the
voltage drop low. An optional 24 V auxiliary power supply may be necessary
when using high-powered actuators, in order to be able to drive these via
the electronic outputs.
AS-Interface masters/gateways are supplied with 24 V directly or from the
AS-Interface.
Commissioning can be performed directly at the master/gateway using
function keys and the graphical display, a PC or PLC are not required.
The attachment of a new slave is "plug and play": Connection, "teach-in" on
the master, done. The addressing of the same type of slave is automatic af-
ter an exchange. Slaves can be connected or disconnected while the net-
work is in use.
The connection of sensors and actuators to the interface module is complet-
AS-Interface ed using plug connectors, screw terminals, or cage-clamp terminals. Inputs,
that is, sensors or mechanical contacts, can be supplied with power from
the AS-Interface.
Pepperl+Fuchs offers a wide variety of connection accessories for simple
installation (for instance, cable gland in M12 or terminals, screw adaptors
for housing installation) and of course various types of AS-Interface flat ca-
ble. A tool for the quick stripping of flat cable is also available.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
14 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
Power Rail
For the control cabinet, there are either distributor terminals as sub-distrib-
utors to the control cabinet modules, power supply, and master, or alterna-
tively the use of units with integrated Power Rail connections. There are two
different types of Power Rail: PR-05 and UPR-05.
In the PR-05, there is a 50 cm long inset component in the 35 mm tophat
rail per EN 50022. The PR-05 has a 20 mm mounting grid and can be short-
ened in 40 mm increments. The PR-05 can be extended using appropriate
adaptors (VE-PR).
The UPR-05 is a gridless Universal Power Rail, which is supplied in lengths
of 2 m and can be shortened at any point. Included in the delivery package,
besides the rail itself, are the C-rail, a cover plate for mechanical and elec-
trical protection of the inset component, and 2 end caps. If the modules are
vertically mounted, an end terminal (for instance TS35 type 2) should be
used to prevent the module from slipping down.

PR-05 UPR-05

The operating principle of both types of Power Rail is the same. Five con-
ductors are integrated into the insert component, of which two are used for
the transmission of the AS-Interface signal. If a module or the master/gate-
way is connected to the AS-Interface line, this node applies the AS-Inter-
face signal to the Power Rail conductors. All other modules are then con-
nected to the AS-Interface line by snapping them onto the tophat rail. Mod-
ules are snapped onto the rail vertically from above.

S -I nt erface, example ap-


A y
s a bo ut the ion, and man -Interface -
ot e la t AS
More n ng the instal in the book " hs
n f ig u ri f o un d epp er l+Fuc
co e
s can b ailable from
P
c a t io n
pli av
m p en dium“,
Co
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 15
AS-Interface - Introduction
1.4 AS-Interface specification 2.1

Functional description of the


AS-Interface specification 2.1
With the AS-Interface specification 2.1, which was defined in 1999 by the
AS-Interface Association as a backwards-compatible extension retaining
the protocol and physical parameters, significant advantages for the user
were introduced:
• Number of nodes increased from 31 standard slaves to
62 A/B slaves,
• enhanced diagnostic function with peripheral error bit,
• simple analogue value transmission with internal data handling,
• extension of the ID codes of the nodes.
Devices in accordance with specification 2.1 are denoted on data sheets
with this symbol.
62
Spec 2.1 62 nodes on AS-Interface network
To take advantage of these possibilities, a VB... Master/Gateway is needed.
Standard slaves (as in specification 2.0), thanks to backwards compatibility,
can still be connected to a new master using specification 2.1. However,
two of the 62 possible addresses are occupied by one standard slave. The
use of A/B Slaves on an "old" master is possible, by always setting the se-
lect bit to logical "0". Despite this, we don't recommend it, since a change to
this bit will change the address, and it may thus be impossible to talk to the
slave due to such a configuration error.
The master message is almost unchanged in the specification 2.1. The only
change is that the select bit "SEL" is transmitted in what used to be the
fourth output bit "I3", which in addition to the address bits A0 ... A4 enables
the extended A/B addressing.
Each address can therefore be split into A and B addresses, i.e. in address-
es 15A and 15B.
Since the fourth output bit is now used as an additional address bit, only 3
output bits per slave can now be transmitted, that is, per AS-Interface net-
work 3* 62 = 186 output bits are set. The slave response remains un-
changed, and there are now 4 * 62 = 248 bits of input data available.
Standard slaves can easily be used with a "new" VB... master, however, the
following changes apply:
• A standard slave occupies both A and B addresses and thus reduces the
maximum number of nodes by one.
• Standard slaves on a "new" VB... master/gateway are recognised using
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the identification code (ID code) and can still have 4 output data bits.
Analogue modules and safe modules occupy a full address, even if these
devices are designed to specification 2.1. This allows the response time of
these modules to be kept to a minimum.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
16 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
Diagnostic function with peripheral error
Besides communications disturbances (i.e. erroneous messages), the mas-
ter can also detect hardware errors which occur on the slave. These periph-
FAULT eral error messages can be used to power down systems in case of error,
since sensor signals may no longer be safely available. It is also possible
simply to evaluate stored data statistically in the master under "LFS" (list of
faulted slaves), in order to evaluate system safety. A red LED display is lo-
PWR cated on the slave. This simplifies the location and correction of errors. An
extended diagnostic also makes it possible to locate even sporadically oc-
curring problems with configuration and communications and evaluate
them with the AS-i Control Tools. This information can be processed in the
PLC using the command interface and for instance then displayed in clear
text to the operator on a remote display.

Analogue transmission
The AS-Interface protocol allows the transmission of 4 bits in one cycle.
A With the analogue profile S7.3, seven messages can be collected in the
D master within only 35 ms, and output as a 16-bit analogue value. This was
Spec 2.1 only possible using an application program in specification 2.0. The output
of analogue control values as 0 V ... 10 V or 4 mA ... 20 mA signals is pos-
sible.

Extension of ID codes:
A/B slaves have ID codes = Ahex, while standard slaves have a different ID
code of Ahex. So as to distinguish the different profiles (types of slave), two
further identification codes were introduced, the ID1 code and the ID2 code.
The IO code and the ID2 code describe the profile of the A/B slaves com-
pletely and are permanently stored in the slave.

Transfer rate and cycle time


The bit transmission rate of the AS-Interface is about 167 kBaud, in order
to make the system very resistant to cable reflexions and errors even with
complex topologies, while still eliminating the need for termination resistors.
The cycle time is, however, a deciding factor for small quantities of data.
When fully loaded, masters on specification 2.0 (31 slaves or 124 binary
sensors + 124 binary actuators) have a maximum cycle time of 5 ms, and
masters on specification 2.1 in extended mode (62 slaves, or 248 binary
sensors + 186 binary actuators) have a maximum cycle time of 10 ms. The
cycle time can be shortened by reducing the number of nodes or by ad-
dressing A/B slaves in standard mode. Every unoccupied slave address
saves 150 µs. This makes the AS-Interface one of the fastest bus systems.
In a mixed system with standard slaves and A/B slaves, standard slaves are
interrogated on each cycle and A/B slaves every other cycle. On the nth cy-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

cle, all A slaves are addressed, and on the n+1-th cycle, all the B slaves.
The master can use the configuration to detect which addresses are unoc-
cupied and doesn't interrogate these at all. If only one (either A or B) ad-
dress is assigned to an A/B slave on the AS-Interface network, then these
slaves are interrogated on every cycle. The frequency of interrogation can
be increased in this way.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 17
AS-Interface - Introduction
The AS-Interface bus protocol
The AS-Interface message is constructed in a very compact way. For the
user, this all occurs in the background, and it is presented here only to give
you a better understanding of data transmission.
The slave response, always 7 bits long after the 14-bit master query, takes
the following form:

Master call SB CB A4 A3 A2 A1 A0 I4 SEL I2 I1 I0 PB EB

• 1 start bit (SB, always "0")


• 1 control bit (CB)
• 5 address bits (A0 ... A4) plus SEL bit for A/B address for expansion to 62
slaves
• 5 data bits (I0, I1, I2, I4)
• 1 parity bit (PB)
• 1 end bit (EB, always "1")

The AS-Interface master uses the control bit to tell the slave whether this
message is a command (i.e. read I/O configuration, read ID code, etc.) or a
data or parameter call.
Together with the SEL bit, the 5 address bits denote the slave being ad-
dressed. With 5+1 Bits, 64 nodes can be addressed. Address 0 must al-
ways be unoccupied, since it is used for automatic addressing after an ex-
change. Thus up to 62 slaves can be addressed.
In a data or parameter call (CB = "0"), the I4 bit is used to distinguish be-
tween
I4 = "0" ==> parameter call
I4 = "1" ==> data call
.
The bits I0 ... I2 contain the output data, by which up to 3 outputs can be
controlled or 3 parameter bits transmitted. The entire message is secured
with a parity bit and is concluded with an end bit. In specification 2.0 (stand-
ard mode) the I3 bit was available as a fourth output bit, which is now used
as select bit (SEL) when extended-mode addressing is in operation. If
slaves built to specification 2.1 can be operated in standard mode, the I3 bit
can also be used as an output bit.
In the slave response, besides the 4 bits of input data, only the start bit (SB),
the parity bit (PB), and the end bit (EB) are transmitted.

Slave response
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

SB I3 I2 I1 I0 PB EB

The master cyclically interrogates the unique addresses (1A, 1B, 2A, 2B,
3A...31A, 31B) of all slaves in turn in a polling process. The addresses in
use are stored in the master's configuration. It only queries these existing
addresses, which shortens the cycle time correspondingly.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
18 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
Summary of parameters
Parameters Topology: Arbitrary: Line, star, tree, etc.
Number of nodes: 62 AS-Interface slaves
(max. 4 x 62 binary inputs
and 3 x 62 outputs)
Access method: Master/Slave
Address assignment: Via master, with addressing unit, or automatically
upon exchange
Cable: Unshielded two-conductor cable,
round cable 2 x 1.5 mm2 or
AS-Interface flat cable 2 x 1.5 mm2
Network length: 100 m overall length
with 2 repeaters up to a max. of 300 m between
master and end of bus cable,
in star topology larger overall length with additional
repeaters
Transfer rate: approx. 167 kBit/sec
Cycle time: max. 10 ms with 62 A/B slaves
El. interface: Data transfer:
APM with sin2 pulses
Power supply: approx. 30.5 V DC,
max. 8 A total current
Auxiliary power: 24 V DC, max. 8 A
Bit encoding: Manchester
Data/message: 4 bits bidirectional
Data security: Signal quality monitoring +
1 parity bit, corresponds to HD = 4 (Hamming Dis-
tance)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 19
AS-Interface - Introduction
1.5 Configuration and installation of a system
with AS-Interface in 4 steps

Does the system size fit?

STEP 1 The number of inputs and outputs needed must fit the number of AS-Inter-
face networks. With a full load of 62 4E3A modules, 248 inputs and 186 out-
puts within an AS-Interface network are possible. If, however, due to local
system layout, not all the input or outputs on a slave are used, or if analogue
modules or standard slaves are connected, the number of addresses is re-
duced, since these slaves "use up" an entire address. If safety-related com-
ponents are integrated, these must be connected to safe slaves, which also
require an entire address. If the diagnostics of the safety monitor need to be
interrogated at the master, then the monitor must also be assigned a full ad-
dress. In time-critical applications, the B address can be left free, so that the
A-addressed slave can be interrogated on every cycle, this allows a cycle
time < 5 ms (instead of < 10 ms) even at full load. These rules influence the
possible number of total inputs and outputs.
If the number of nodes on one AS-Interface network is insufficient, then a
double master can also be used to drive two AS-Interface networks. Mas-
ters/gateways installed in parallel in the control cabinet can also enable sim-
ple fulfilment of the required system size. If signals from one AS-Interface
network need to be transferred to a second one, data coupler modules can
be used, which transfer 4 bits at a time from one network to the other.
In extensive installations, line lengths of over 100m (this includes spur lines
to intelligent sensors) may be necessary. By using repeaters (maximum of
2 in series), the length of the line can be extended to up to 300 m from the
master. One or two additional power supplies (or power extenders) will be
necessary. A network with star topology, with more repeaters, can attain
very large overall line lengths. The topology of the network is arbitrary: Star,
tree, line, spur lines, or other.

Specifying the power supply

STEP 2 The power supply needed can be derived from the power consumption of
the individual devices. The following typical values can be used:
• Current consumption by the master: approx. 200 mA
• Per AS-Interface module: approx. 30 mA … 80 mA
(depending on type)
• Per sensor input: approx. 5 mA
• Per sensor: ca. 10 mA … 80 mA (depending
on type)
(inductive typically 10 mA,
optical typically 35 mA)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

• Per analogue module: approx. 80 mA


• Per safety monitor (1/2 channel): 150/200 mA
This makes it possible to estimate whether a 2.8 A, a 4 A or an 8 A AS-In-
terface power supply will be necessary. Exact power consumption data can
be found in the corresponding data sheets.
If a 24 V auxiliary power supply is also necessary, the power consumptions
must also be totalled for it, and a corresponding 24 V power supply select-
ed.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
20 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
Address configuration of slaves and wiring

STEP 3 It is possible to configure the addressing of slaves at your desk or work-


bench using the VBP-HH1 hand-held device, label them, and then install in
the planned locations. This has the advantage, that the addressing and la-
beling can be performed rationally. However, it is then very important to
take care to match addresses to functions during installation. This proce-
dure is generally to be recommended.
If modules are first installed and then connected by flat cable to the AS-In-
terface line, addressing and labeling must be performed with the hand-held
device in a second step, since all slaves have address 0 as delivered. It is
important to ensure that no addresses are duplicated.
The addressing of intelligent sensors with integrated AS-Interface chips can
easily be performed by plugging the sensors into the hand-held device. Ap-
propriate contact pins are integrated for M12, VariKont M and VariKont de-
signs. Modules with addressing jacks are connected via a connector cable.
The slave is thus disconnected from the network and other modules and
can only be accessed through the hand-held device.
The hand-held device can also be used for reassigning addresses on the
AS-Interface network. The master must simply be disconnected from the
network and the hand-held device connected to the yellow AS-Interface ca-
ble. All nodes on the network can then be addressed selectively. There is
the additional possibility of performing addressing directly on the master us-
ing the display, or using the AS-i Control Tools software.
After all modules have been addressed and connected, the AS-Interface flat
cable is connected to the AS-Interface power supply, and the 24 V auxiliary
power supply optionally connected. The master and any other control cab-
inet modules should be wired in parallel. Adaptors from flat cable to flexible
leads, or Power Rail technology, may be used to do this.
Neither the AS-Interface positive or negative may be earthed at any point!
Only the earth connection of the power supply may be connected to earth.
To ensure correct earthing, we offer power supplies and gateways with
earth monitoring functions.

Configuration of masters/gateways

STEP 4 Finally, it must be defined in the master/gateway which nodes are connect-
ed to the AS-Interface network. This is done by pressing the MODE button
on the front of the gateway for about 5 seconds (switching into configuration
mode) and then pressing the MODE button again (switches back to protect-
ed operating mode). Alternatively, on masters with graphical displays, the
"Quick setup" menu can be called up for configuration. After successful con-
figuration of the master/gateway, the red "Config. Error" LED will be turned
off.
Field bus master simulators are available for PROFIBUS, CANopen, De-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

viceNET. and ModBus. EtherNet and Interbus gateways can be simulated


using the AS-Interface Control Tools and tested including the higher-order
field bus connection.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 21
AS-Interface - Introduction
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
22 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction

2 Masters and Gateways

Masters and
Gateways
The AS-lnterface Masters / Gateways are the core components of an AS-
Interface system. These devices perform a cyclic interrogation of the slaves
via a polling procedure and represent the link to the higher level system in
the form of a decentrally operating, flexible and fast control unit. The devic-

Extender, Repeaters
Power Supplies,
es are also available with a control function (Integrated PLC with inputs, out-
puts, timers, and counters) for autonomous operation.
Masters are available in various versions and construction types, for exam-
ple with a large graphics display for on-site diagnosis. These cover not only
peripheral faults, even statistical faults can be evaluated via an internal fault
counter and used for trouble-shooting if necessary.

Safety at work
Of course, all data can also be transferred via the field bus interface for con-
trol purposes.
Addressing and parameter assignment (On initial installation, for example)
can take place directly on the master/gateway. There are also commission-

Control cabinet
ing tools available, for instance the AS-i Control Tools software, VAZ-SW-

I/O Modules
ACT32. This software package allows simple, quick, and easy commission-
ing of the AS-Interface network via the serial interface of a PC.
Various interfaces are available for connecting the higher level control sys-
tem:

Field application
I/O Modules
• Serial interface (RS 232)
• PCI bus for direct connection to a PC
• Field bus interface with the gateways (For all current field bus systems,
e. g. PROFIBUS DP, DeviceNet, INTERBUS, etc.)

Analogue modules
A gateway consists of two parts:
• The AS-Interface master (e. g. to AS-Interface specification V2.1) for
management of the AS-Interface network.
• The interface to the higher level field bus system (e. g. as PROFIBUS
slave) for transfer of the data to the control system.

Other modules
For field applications Pepperl+Fuchs can supply masters/gateways in
protection class IP67 in the G4 housing. These devices are ideal for decen-
tralisation with AS-Interface, since the devices can be installed close to the
application. The restriction to 100 m of cable is of no great consequence
and the large distances can be bridged using the higher level field bus sys-

Inductive sensors
tem.
The unified menu structure and philosophy of the masters/gateways simpli-
fies operation despite a large number of devices.
Master/Gateways designed to specification 2.1 have the type codes VBM...
oder VBG..., while devices designed to specification 2.0 have the codes
Photoelectric

VAM... or VAG...
sensors

Devices with codes VBG-...-D oder VBG-...-DMD are equipped with a large
graphics display for extra ease of operation.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

For your peace of mind:


This AS-Interface logo indicates that the AS-Interface devices are "Certifi-
cated" products. It's there to reassure you that you will experience no neg-
ative mutual interference effects from AS-Interface devices in your system.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 23
AS-Interface - Introduction
2.1 Master
Masters and
Gateways

for primary control Masters with RS 232 serial interfaces are frequently used as point-to-point
(RS 232,RS 422,RS 485)
connections for local solutions where a short distance to the control node is
involved (Typically up to 10 m). Since these masters also contain a control
function with SPS functionality (Typically 16 kB program memory, 8 kB user
AS-Interface AS-Interface AS-Interface
Extender, Repeaters

memory, 1024 timer and 1024 counter), they are frequently used as auton-
Power Supplies,

CTRL CTRL CTRL


omous control units for sub areas. The program processing time is approx-
imately 1000 instructions every 2 ms.
EV
The programming language is based on STEP5®. After commissioning the
connection between the PC and the master is broken and the application
operates independently. This master is available for installation in the con-
Safety at work

trol cabinet in the construction types KF (Removable terminals, power rail


connection) and K5 (Screw terminal connection) or as a plug-in card for the
PC (for instance VAM-CTR-PC2). If PC masters are used, then the struc-
ture is similar to the structure for AS-Interface masters, except that the mas-
ter is integrated in the PCI slot of the PC.
Control cabinet

Dual masters are also available: in these, two independent masters are lo-
I/O Modules

cated in a single housing.

2.2 Gateways
Field application
I/O Modules

The gateway places the data at the disposal of the higher-level field bus
Host (PROFIBUS, INTERBUS, DeviceNet, EtherNet, Modbus, Modbus+, CAN,
Fieldbus
CC-Link, ...), in the requisite format. If devices with control functionality are
F
used (see selection table), a preprocessing of AS-Interface data can be per-
formed, just as with masters, so that sensors and actuators on the same
Analogue modules

Gateway
AS-Interface
AS-Interface network can be directly connected with one another via the
control functionality. This makes it necessary to transmit only a little data for
display in the higher-level bus system. This reduces the system load on the
higher level bus system and hence increases performance. The pre-
processing also reduces the memory requirement and the processing time,
which in turn decreases the cycle time.
Other modules

Here, too, there are gateways available for the switch cabinet (KF, K20, or
K5) and for field application (G4).
EV
Inductive sensors

2.3 Programming with AS-i Control Tools


This software is based on Windows (95, 98, ME, NT4, 2000, XP). After a
serial connection has been prepared for the master an easy to follow con-
figuration assistant guides you through all the further steps required and
provides help text support. The AS-Interface network is displayed graphical-
Photoelectric

ly. A fault elimination routine helps in the event of nonsensical results. The
sensors

finished configuration can be saved as a file and sent via download to the
master/gateway. This means that in series production similar configurations
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

can be easily prepared and the configuration can be printed out for the pur-
pose of system documentation.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
24 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Introduction
Overview of available AS-Interface Masters and Gateways:

Masters and
Gateways
(Sorted by design. Dimensions and connection type can be found in the corresponding data sheets.)

Design Type code Interface Spec. Features Display Page

Extender, Repeaters
Power Supplies,
PLC functionality
PCI VBM-CTR-PCI-DM PCI 2.1 dual master - 28
mounted in PCI slot

VBM-CTR-KF-R2 RS 232 2.1 PLC Functionality 26

Safety at work
2
VBG-PB-KF-R4 PROFIBUS DP V1 2.1 7-Segment 34
LEDs
KF
VAG-MOD-KF-R4 Modbus 2.0 PLC Functionality 46

Control cabinet
I/O Modules
VAG-IBS-KF-FB INTERBUS 2.0 LCD 42

VBG-PB-K5-R4-DMD PROFIBUS DP V1 2.1 Dual master 36

Field application
I/O Modules
VBG-IP-K5-DM EtherNet 2.1 Dual master 44
graphical
LCD
K5 VBG-DN-K5-D DeviceNet 2.1 48
display,

Analogue modules
two lines
VBG-DN-K5-DMD DeviceNet 2.1 Dual master 50

VBG-CAN-K5-D CANopen 2.1 52

Other modules
VBG-PB-K20-D PROFIBUS DP V1 2.1 * 30
backlit LCD
K20 display,
* clear text
VBG-PB-K20-DMD PROFIBUS DP V1 2.1 32
Dual master

Inductive sensors
VBG-PB-G4F-R4 PROFIBUS DP V1 2.1 Protection class IP67 38

2
PLC Functionality
G4 VAG-PB-G4F-R4 PROFIBUS DP 2.0 7-Segment 40
Protection class IP67
LEDs

VBG-CCL-G4F CC-Link 2.1 Protection class IP67 54


Photoelectric
sensors

* Also available with PLC functionality on request.


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

The following data sheets are sorted by interface:


Rotary encoders

RS 232 from page 26


PROFIBUS from page 30
INTERBUS from page 42
EtherNet from page 44
Modbus from page 46
DeviceNet from page 48
Accessories

CAN, CANopen and CC-Link from page 52

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 25
VBM-CTR-KF-R2

AS-Interface master VBM-CTR-KF-R2


Dimensions
Masters and
Gateways

60 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application
I/O Modules

Order code
AS-Interface - 4
VBM-CTR-KF-R2 AS-Interface +
5

AS-Interface master RS 232 cabinet AS-Interface - 24


23
module AS-Interface +
Analogue modules

33 Sub-D socket
AS-Interface - 3
32 RxD
AS-Interface + 2
TxD
5
GND
Features 5
Power Rail 4
• Stand-alone master with PLC 25
RxD
26
functionality 27
TxD
GND
• Two-digit LC display 35
Other modules

Screen
36
• Voltage supply from AS-Interface RS 232
• Automatic baud rate detection
• Programmable slave addresses
• Display of detected slaves
Inductive sensors

• Fault diagnosis
• Parameterisation and monitor
software Indicating/operating means
• Power Rail connection
• RS 232 interface 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Photoelectric
sensors

POWER

SER ACTIVE
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

CONFIG ERR

U ASI MODE
Rotary encoders

ASI ACTIVE

PRG ENABLE

PRJ MODE SET


RS 232
Accessories

19 20 21 22 23 24 25 26 27
28 29 30 31 32 33 34 35 36

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
26 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface master VBM-CTR-KF-R2
Technical data Function

Masters and
General specifications

Gateways
The VBM-CTR-KF-R2 is a stand-alone mas-
AS-Interface specification V2.11
ter with integrated PLC functionality. The
Indicators/operating means design of this master is ideal for use in a cab-
LC display, two-digit address display, error message inet. Its housing, only 60 mm wide, occupies
LED AS-i ACTIVE AS-Interface operation normal; LED green little space in a cabinet installation. The
LED CONFIG ERR configuration error; LED red VBM-CTR-KF-R2 is installed by snapping it

Extender, Repeaters
Power Supplies,
LED PRG ENABLE autom. programming; LED green onto the 35 mm DIN Rail per EN 50022, with
LED ENERGY voltage ON; LED green the integrated Power Rail. The AS-Interface
LED PRJ MODE projecting mode active; LED yellow signal is transmitted through conductors,
LED SER ACTIVE interface in operation; LED green which are integrated into the Power Rail.
LED U AS-i AS-Interface voltage; LED green Thus all cabinet modules in KF housing can
Switch SET Selection and setting of a slave address be connected to the AS-Interface cable by
Button MODE Mode selection/save configuration simply snapping them onto the DIN Rail.

Safety at work
Electrical specifications Removable terminals for leading the AS-
Insulation voltage Ui ≥ 500 V Interface cable through the cabinet are avail-
Rated operational voltage Ue from AS-Interface able. These terminals are coded and allow
Rated operational current Ie ≤ 150 mA "online" maintenance, i. e. while the system
Interface is under power. The connection to the AS-
Interface type RS 232 Interface power supply is established through
Transfer rate 1200 , 2400 , 4800 , 9600 , 19200 , 38400 or 57600 Bit/s these terminals which can also be used for

Control cabinet
, Automatic baud rate detection the serial interface. A 9-pin Sub-D connector

I/O Modules
Cable length max. 30 m is also available. Power to the master is sup-
Connection plied by the AS-Interface cable.
AS-Interface removable coded terminals, Power Rail Two push buttons are used for address
Standard conformity assignment of the AS-Interface slaves and
Electromagnetic compatibility IEC 62026-2, EN 61326 acceptance of the desired configuration. In
configuration mode, all detected AS-Interface

Field application
Fieldbus standard IEC 62026-2
slaves are displayed on the 2-digit LCD. In

I/O Modules
Ambient conditions
normal operation, the LCD is blank unless
Ambient temperature 0 ... 55 °C (273 ... 328 K)
the master detects a faulty AS-Interface
Storage temperature -25 ... 70 °C (248 ... 343 K)
slave. There are 7 LEDs on the front panel,
Mechanical specifications
showing the current status of the AS-Inter-
Protection degree IP20 according to EN 60529 face line.
Mass 420 g

Analogue modules
PLC functionality
Software The VBM-CTR-KF-R2 provides 16 kB of pro-
gram memory (approx. 2500 single binary
The AS-i Control Tools software is supplied as restricted version together with the documen-
commands), 8 kB of data memory, 1024
tation. The software performs addressing, programming and monitoring of the AS-Interface
counters and 1024 timers for PLC functional-
network. In addition, it contains an editor that creates programs for the integrated PLC func-
ity. These capacities suffice to process data
tionality. The full version of the AS-i Control Tool is available as an accessory and features an
on the AS-Interface. Thus the master can

Other modules
expanded diagnostics monitor as well as a larger program memory for AS-Interface Control
also be operated in "stand-alone" mode. The
which makes it possible to detect faulty telegrams of slaves.
program processing time is approximately
1000 word commands every 2 ms. The pro-
gramming language is based upon the
STEP5 programming language.

Inductive sensors
Accessories
VAZ-SW-ACT32
Full version of the AS-i Control Tools
UPR-05
Universal Power Rail with DIN rail and
cover, 5 leads
Photoelectric
sensors

UPR-E
End cap for UPR-03 und UPR-05
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 27
VBM-CTR-PCI-DM

AS-Interface master VBM-CTR-PCI-DM


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application
I/O Modules

Order code
VBM-CTR-PCI-DM Network 1
AS-Interface +
PCI double master for 2 AS-Interface
networks AS-Interface -
Analogue modules

µP PCI bus
interface
Features Network 2
• V2.1 master AS-Interface +

• Stand-alone master with PLC AS-Interface -

functionality
Other modules

• Connection to PCI bus


• 2 AS-Interface networks
• Simple installation
• PC-independent program processing
Inductive sensors

• Does not require any interrupts


• Up to 4 VBM-CTR-PCI-DM per PC
• Connectable watchdog Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface network 1 AS-Interface network 2


Rotary encoders

AS-Interface +

AS-Interface +

AS-Interface +

AS-Interface +
AS-Interface -

AS-Interface -

AS-Interface -

AS-Interface -
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
28 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface master VBM-CTR-PCI-DM
Technical data Function

Masters and
General specifications

Gateways
The VBM-CTR-PCI-DM is an AS-Interface
AS-Interface specification V2.11
double master with PLC functionality, espe-
Electrical specifications cially designed for operation with a PCI bus,
Insulation voltage Ui ≥ 500 V which is available in every modern PC. The
Rated operational voltage Ue 5 V DC and AS-Interface voltage plug-and-play properties of the hardware and
Rated operational current Ie ≤ 200 mA from power supply, driver permit up to 4 masters to be operated

Extender, Repeaters
≤ 70 mA from AS-Interface

Power Supplies,
at the same time, and thus render manual
Interface configurations redundant. The efficient event
Interface type 32 bit PCI bus interface control of the card allows data to be
Ambient conditions exchanged rapidly. Thus the performance of
Ambient temperature 0 ... 55 °C (273 ... 328 K) the system is considerably enhanced. An
Storage temperature -25 ... 70 °C (248 ... 343 K) Interrupt is not necessary; it does however
Mechanical specifications support the event control on system level

Safety at work
Protection degree IP20 according to EN 60529 and thus enhances the performance of the
Construction type Short PCI card system once again.
Communication between AS-Interface mas-
Software ter and PC is monitored by means of a
switchable watchdog. In case the PC has a
The AS-i Control Tools software is supplied as restricted version together with the documen- system crash, the AS-Interface master is set
tation. The software performs addressing, programming and monitoring of the AS-Interface "off-line" and thus all outputs are set inactive.

Control cabinet
network. In addition, it contains an editor that creates programs for the integrated PLC func- Extended diagnostic functions allow sporadi-

I/O Modules
tionality. The full version of the AS-i Control Tool is available as an accessory and features an cal configuration errors to be located, and
expanded diagnostics monitor as well as a larger program memory for AS-Interface Control AS-Interface communication to be assessed
which makes it possible to detect faulty telegrams of slaves. with regard to quality.
Drivers are available for Windows
95/98/2000/NT.

Field application
PLC Functionality

I/O Modules
The VBM-CTR-PCI-DM provides 4 kBytes of
program memory, 8 kBytes of main memory,
1024 counters and 1024 timers for PLC func-
tionality. These capacities suffice to process
data on the AS-Interface. Thus the master

Analogue modules
can also be operated in "stand-alone" mode.
The program processing time is 2 ms per
1000 word commands. The programming
language is based on the STEP5 program-
ming language.

Accessories

Other modules
VAZ-SW-ACT32
Full version of the AS-i Control Tools

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 29
VBG-PB-K20-D

AS-Interface gateway VBG-PB-K20-D


Dimensions
Masters and
Gateways

75 76
55 7 20
Extender, Repeaters
Power Supplies,

43
120
Mode
Safety at work

ESC OK
Set

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

+
Field application

- AS-Interface +
I/O Modules

+
- AS-Interface -
Order code .
µP .
VBG-PB-K20-D .

PROFIBUS gateway
Analogue modules

Plug-in jumpers
Pos. 1
a
Features 24 V + –
0V -
• Gateway according to AS-Interface
b –
Sub-D socket
Pos. 2 3
specifikation 2.1 for up to 62 units RxD/TxD-P
8
RxD/TxD-N
• Connection to PROFIBUS DP
Other modules

Screen
• Acyclic communication in accordance
with PROFIBUS DP V1
• Commissioning, without PROFIBUS
Using plug-in jumpers, it is possible to choose whether
communication the master shall be supplied by AS-Interface circuit
Inductive sensors

• All AS-Interface functions can be (pos.1) or via an own power pade (PELV) (pos. 2).
called via PROFIBUS
• Fault diagnosis via LEDs and grafic
display Indicating/operating means
• Easy commissioning, by grafic
RS 232
display
PROFIBUS

J M BLE
-i R

E
AS R

E
CO IBUS

PR CTIV
U IG E

PR NA
OD
PR R
Photoelectric

E
E

NF

-i A
OF
W

• AS-Interface monitor or extended AS-


PO

AS
sensors

Interface diagnostic read via display


• Double adressing detection of von
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface slaves
• Earh fault detection
Rotary encoders

• AS-Interface EMC monitoring VBG-PB-K20-D

Mode
ESC OK
Set
PWR
+AS-i1- +AS-i1-
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
30 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-PB-K20-D
Technical data Function

Masters and
General specifications

Gateways
The VBG-PB-K20-D is a PROFIBUS Gate-
AS-Interface specification V2.11
way in accordance with AS-Interface specifi-
Indicators/operating means cation 2.11 in IP20. The design is especially
LC display, two-digit address display, error message suitable for use in the switch cabinet.
LED BUS ACTIVE PROFIBUS master detected; LED green The VBG-PB-K20-D is a modular PROFI-
LED AS-i ACTIVE AS-Interface operation normal; LED green BUS slave. This means that the user can use

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red the PROFIBUS configuration tool to specify
LED PRG ENABLE autom. programming; LED green what data will be transferred via the PROFI-
LED ENERGY voltage ON; LED green BUS. This makes it possible to adjust the
LED PRJ MODE projecting mode active; LED yellow amount of data to be transferred via PROFI-
LED U AS-i AS-Interface voltage; LED green BUS.
Switch SET Selection and setting of a slave address In addition, this gateway supports acyclical
OK button Mode selection traditional-graphical/confirmation communication of the PROFIBUSDP V1.
Button MODE Mode selection PRJ-operation/save configuration/cursor

Safety at work
These acyclical services can be used to
ESC button Mode selection traditional-graphical/cancel access a mailbox in the gateway that pro-
Electrical specifications vides access to all the data made available
Insulation voltage Ui ≥ 500 V by the AS-Interface/PROFIBUS Gateway.
Rated operational voltage Ue from AS-Interface A push button can be used to accept the tar-
Rated operational current Ie ≤ 180 mA from AS-Interface get configuration and to adjust the PROFI-
Interface BUS address and baud rate. There are 7

Control cabinet
LEDs on the front panel, showing the cur-

I/O Modules
Protocol PROFIBUS
Interface type RS 485 rent status of the AS-i line.
Transfer rate 9.6; 19.2; 44.44; 93.95; 187.5; 500; 1500 kBit/s self-synchro- In the case of the AS-Interface Gateway with
nising graphical display, the AS-Interface circuit can
Connection be placed in service and the test of the con-
PROFIBUS Sub-D interface nected periphery can be kept entirely sepa-
AS-Interface screw terminals rate from the commissioning of the

Field application
PROFIBUS and the programming. On-site

I/O Modules
Ambient conditions
Ambient temperature 0 ... 55 °C (273 ... 328 K) operation with the aid of the graphical display
Storage temperature -15 ... 75 °C (258 ... 348 K) and 4 push buttons makes it possible to
show all functions on the display that are
Mechanical specifications
covered by the AS-i Control Tools software
Protection degree IP20 according to DIN 40050
for other AS-Interface masters. An additional
Mass 420 g

Analogue modules
RS 232-socket offers the option of reading
Construction type terminal rail housing, LDG-A-30
data via gateway, network and function as
part of advanced local diagnostics directly
Software
from the gateway.
The device is supplied with the configuration data files (GSD) as well as a restricted version of
the AS-i Control Tools software. The software performs the addressing, programming and PLC functionality
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available Optionally the gateway is also available with
as an accessory and features an expanded diagnostics monitor as well as a larger program PLC-functionality.

Other modules
memory for AS-Interface Control which makes it possible to detect faulty telegrams of slaves.
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby Accessories
the size of the I/O windows can be conveniently adapted to the AS-Interface circuit's load and
the AS-Interface configuration can be stored within the GSD file. A text file is also created, VAZ-SW-ACT32
which documents the status of AS-Interface data in the gateway's I/O window. Full version of the AS-i Control Tools
Note:

Inductive sensors
The VAZ-PB-SIM accessory is required for the AS-i Control Tool. VAZ-PB-SIM
PROFIBUS master simulator

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 31
VBG-PB-K20-DMD

AS-Interface gateway VBG-PB-K20-DMD


Dimensions
Masters and
Gateways

75 76
55 7 20
Extender, Repeaters
Power Supplies,

43
120
Mode
Safety at work

ESC OK
Set

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

+
Field application

-
I/O Modules

+
AS-Interface 1
Order code -
.
µP .
VBG-PB-K20-DMD .
+
AS-Interface 2
PROFIBUS gateway, double master for -
+
2 AS-Interface networks -
Analogue modules

Plug-in jumpers
Pos. 1
a
Features 24 V + –
0V -
• Gateway according to AS-Interface b –
Sub-D socket
Pos. 2 3
specifikation 2.1 for up to 62 units RxD/TxD-P
8
RxD/TxD-N
• Connection to PROFIBUS DP
Other modules

Screen
• 2 AS-Interface networks
• Acyclic communication in accordance
with PROFIBUS DP V1
Using plug-in jumpers, it is possible to choose whether
• Commissioning, without PROFIBUS the master shall be supplied by AS-Interface-1 circuit
Inductive sensors

communication (pos.1) or via an own power pade (PELV) (pos. 2).

• All AS-Interface functions can be


called via PROFIBUS
• Fault diagnosis via LEDs and grafic Indicating/operating means
display
RS 232
PROFIBUS

• Easy commissioning, by grafic


J M BLE
-i R

E
AS R

E
CO IBUS

PR CTIV
U IG E

PR NA
OD
Photoelectric

PR R

E
E

NF

-i A
OF
W

display
PO

AS
sensors

• AS-Interface monitor or extended AS-


Interface diagnostic read via display
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

• Double adressing detection of von


AS-Interface slaves
Rotary encoders

• Earh fault detection VBG-PB-K20-DMD


• AS-Interface EMC monitoring
Mode
ESC OK
Set
PWR PWR
+AS-i1- +AS-i1- +AS-i2- +AS-i2-
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
32 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-PB-K20-DMD
Technical data Function

Masters and
General specifications

Gateways
The VBG-PB-K20-DMD is a PROFIBUS
AS-Interface specification V2.11
Gateway with 2 AS-Interface masters in
Indicators/operating means accordance with AS-Interface
LC display, two-digit address display, error message Specification 2.11 in IP20. The design is
LED BUS ACTIVE PROFIBUS master detected; LED green especially suitable for use in the switch cabi-
LED AS-i ACTIVE AS-Interface operation normal; LED green net.

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red The VBG-PB-K20-DMD is a modular PROFI-
LED PRG ENABLE autom. programming; LED green BUS slave. This means that the user can use
LED ENERGY voltage ON; LED green the PROFIBUS configuration tool to specify
LED PRJ MODE projecting mode active; LED yellow what data will be transferred via the PROFI-
LED U AS-i AS-Interface voltage; LED green BUS. This makes it possible to adjust the
Switch SET Selection and setting of a slave address amount of data to be transferred via PROFI-
OK button Mode selection traditional-graphical/confirmation BUS.
Button MODE Mode selection PRJ-operation/save configuration/cursor

Safety at work
In addition, this gateway supports acyclical
ESC button Mode selection traditional-graphical/cancel communication of the PROFIBUSDP V1.
Electrical specifications These acyclical services can be used to
Insulation voltage Ui ≥ 500 V access a mailbox in the gateway that pro-
Rated operational voltage Ue from AS-Interface vides access to all the data made available
Rated operational current Ie ≤ 180 mA from AS-Interface by the AS-Interface/PROFIBUS Gateway.
Interface A push button can be used to accept the tar-

Control cabinet
get configuration and to adjust the PROFI-

I/O Modules
Protocol PROFIBUS
Interface type RS 485 BUS address and baud rate. There are 7
Transfer rate 9.6; 19.2; 44.44; 93.95; 187.5; 500; 1500 kBit/s self-synchro- LEDs on the front panel, showing the cur-
nising rent status of the AS-i line.
Connection In the case of the AS-Interface Gateway with
PROFIBUS Sub-D interface graphical display, the AS-Interface circuit can
AS-Interface screw terminals be placed in service and the test of the con-

Field application
nected periphery can be kept entirely sepa-

I/O Modules
Ambient conditions
Ambient temperature 0 ... 55 °C (273 ... 328 K) rate from the commissioning of the
Storage temperature -15 ... 75 °C (258 ... 348 K) PROFIBUS and the programming. On-site
operation with the aid of the graphical display
Mechanical specifications
and 4 push buttons makes it possible to
Protection degree IP20 according to DIN 40050
show all functions on the display that are
Mass 420 g

Analogue modules
covered by the AS-i Control Tools software
Construction type terminal rail housing, LDG-A-30
for other AS-Interface masters. An additional
RS 232-socket offers the option of reading
Software
data via gateway, network and function as
The device is supplied with the configuration data files (GSD) as well as a restricted version of part of advanced local diagnostics directly
the AS-i Control Tools software. The software performs the addressing, programming and from the gateway.
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available
as an accessory and features an expanded diagnostics monitor as well as a larger program PLC functionality

Other modules
memory for AS-Interface Control which makes it possible to detect faulty telegrams of slaves. Optionally the gateway is also available with
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby PLC-functionality.
the size of the I/O windows can be conveniently adapted to the AS-Interface circuit's load and
the AS-Interface configuration can be stored within the GSD file. A text file is also created, Accessories
which documents the status of AS-Interface data in the gateway's I/O window.
Note: VAZ-SW-ACT32

Inductive sensors
The VAZ-PB-SIM accessory is required for the AS-i Control Tool. Full version of the AS-i Control Tools
VAZ-PB-SIM
PROFIBUS master simulator
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 33
VBG-PB-KF-R4

AS-Interface gateway VBG-PB-KF-R4


Dimensions
Masters and
Gateways

60 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application
I/O Modules

Order code
AS-Interface - 4
VBG-PB-KF-R4 AS-Interface +
5

PROFIBUS gateway cabinet module 24 Sub-D socket


AS-Interface -
23 5
AS-Interface + VP
6
Analogue modules

33 DGND
AS-Interface - 3
RxD/TxD-P
32
AS-Interface + 8
RxD/TxD-N

Features 5
Power Rail 4
• Gateway according to AS-Interface 25
RxD/TxD-N
26
specifikation 2.1 for up to 62 units RxD/TxD-P
35
• Connection to PROFIBUS DP
Other modules

Screen
36
• Acyclic communication in accordance PROFIBUS
with PROFIBUS DP V1
• Commissioning, without PROFIBUS
communication
Inductive sensors

• All AS-Interface functions can be


called via PROFIBUS
• Power supply from AS-Interface
• Coded, removable terminals Indicating/operating means
• Error diagnostics via LEDs and LC
1 2 3 4 5 6 7 8 9
display 10 11 12 13 14 15 16 17 18
Photoelectric

• Parameterisation and monitor


sensors

POWER
software
BUS ACTIVE
• Power Rail connection
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

CONFIG ERR

U ASI MODE
Rotary encoders

ASI ACTIVE

PRG ENABLE

PRJ MODE SET


PROFIBUS

VBG-PB-KF-R4
Accessories

19 20 21 22 23 24 25 26 27
28 29 30 31 32 33 34 35 36

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
34 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-PB-KF-R4
Technical data Function

Masters and
General specifications

Gateways
The VBG-PB-KF-R4 is a complete AS-Inter-
AS-Interface specification V2.11
face master in accordance with AS-Interface
Indicators/operating means specification 2.11 in IP20. The design of this
LC display, two-digit address display, error message master is especially suitable for use in the
LED BUS ACTIVE PROFIBUS master detected; LED green switch cabinet. The KF cabinet housing of
LED AS-i ACTIVE AS-Interface operation normal; LED green the PROFIBUS Gateway offers all the advan-

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red tages of the serial master, such as Power
LED PRG ENABLE autom. programming; LED green Rail connections and coded, removable ter-
LED ENERGY voltage ON; LED green minals.
LED PRJ MODE projecting mode active; LED yellow The VBG-PB-KF-R4 is a modular PROFI-
LED U AS-i AS-Interface voltage; LED green BUS slave. This means that the user can use
Switch SET Selection and setting of a slave address the PROFIBUS configuration tool to specify
Button MODE Mode selection/save configuration what data will be transferred via the PROFI-

Safety at work
Electrical specifications BUS. This makes it possible to adjust the
Insulation voltage Ui ≥ 500 V amount of data to be transferred via PROFI-
Rated operational voltage Ue from AS-Interface BUS.
Rated operational current Ie ≤ 180 mA from AS-Interface In addition, this gateway supports acyclical
Interface communication of the PROFIBUS DP V1.
Protocol PROFIBUS These acyclical services can be used to
Interface type RS 485 access a mailbox in the gateway that provide

Control cabinet
access to all the data that are made available

I/O Modules
Transfer rate 9.6; 19.2; 44.44; 93.95; 187.5; 500; 1500 kBit/s self-synchro-
nising by the AS-Interface/PROFIBUS Gateway.
Connection Two push buttons are used for address
PROFIBUS RS 485 Interface and removable coded terminals assignment, acceptance of the desired con-
AS-Interface removable coded terminals, Power Rail figuration and for adjustment of the PROFI-
Ambient conditions BUS address and baud rate. In configuration
mode, all detected AS-Interface slaves are

Field application
Ambient temperature 0 ... 55 °C (273 ... 328 K)
displayed on the 2-digit LCD. In normal oper-

I/O Modules
Storage temperature -15 ... 75 °C (258 ... 348 K)
ation, the LCD is blank unless the master
Mechanical specifications
detects a faulty AS-Interface slave. There are
Protection degree IP40 (housing), IP20 (terminals)
7 LEDs on the front panel, showing the cur-
Mass 420 g
rent status of the AS-Interface line.
Software

Analogue modules
Accessories
The device is supplied with the configuration data files (GSD) as well as a restricted version of
the AS-i Control Tools software. The software performs the addressing, programming and VAZ-SW-ACT32
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available Full version of the AS-i Control Tools
as an accessory and features an expanded diagnostics monitor as well as a larger program
memory for AS-Interface Control which makes it possible to detect faulty telegrams of slaves. VAZ-PB-SIM
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby PROFIBUS master simulator
the size of the I/O windows can be conveniently adapted to the AS-Interface circuit's load and

Other modules
UPR-E
the AS-Interface configuration can be stored within the GSD file. A text file is also created,
End cap for UPR-03 und UPR-05
which documents the status of AS-Interface data in the gateway's I/O window.
Note: UPR-05
The VAZ-PB-SIM accessory is required for the AS-i Control Tool. Universal Power Rail with DIN rail and
cover, 5 leads

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 35
VBG-PB-K5-R4-DMD

AS-Interface gateway VBG-PB-K5-R4-DMD


Dimensions
Masters and
Gateways

110 75
Extender, Repeaters
Power Supplies,

100
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

+
Field application

-
I/O Modules

+
AS-Interface 1
Order code -
.
µP .
VBG-PB-K5-R4-DMD .
+
AS-Interface 2
PROFIBUS gateway, double master for -
+
2 AS-Interface networks -
Analogue modules

Plug-in jumpers
Pos. 1
a
Features 24 V + –
0V -
• Gateway according to AS-Interface b –
Sub-D socket
Pos. 2 3
specifikation 2.1 for up to 62 units RxD/TxD-P
8
RxD/TxD-N
• Connection to PROFIBUS DP
Other modules

Screen
• 2 AS-Interface networks
• Acyclic communication in accordance
with PROFIBUS DP V1
Using plug-in jumpers, it is possible to choose whether
• Commissioning, without PROFIBUS the master shall be supplied by AS-Interface-1 circuit
Inductive sensors

communication (pos.1) or via an own power pade (PELV) (pos. 2).

• All AS-Interface functions can be


called via PROFIBUS
• Fault diagnosis via LEDs and grafic Indicating/operating means
display
• Easy commissioning, by grafic
Photoelectric

display POWER VBG-PB-K5-R4-DMD


sensors

MODE /
• AS-Interface monitor or extended AS- PROFIBUS
PROFIBUS

Interface diagnostic read via display


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

CONFIG ERR
OK

U AS-i
Rotary encoders

AS-i ACTIVE ESC

PRG ENABLE
SET /
PRJ MODE

AS-i 1 AS-i 2 PWR CONFIG


+ - + - + - + - a 24V 0V b
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
36 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-PB-K5-R4-DMD
Technical data Function

Masters and
General specifications

Gateways
The VBG-PB-K5-R4-DMD is a PROFIBUS
AS-Interface specification V2.11
gateway with 2 AS-Interface masters in
Indicators/operating means accordance with AS-Interface specification
LC display, two-digit address display, error message 2.11 in IP20. The design is especially suita-
LED BUS ACTIVE PROFIBUS master detected; LED green ble for use in the switch cabinet.
LED AS-i ACTIVE AS-Interface operation normal; LED green The VBG-PB-K5-R4-DMD is a modular

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red PROFIBUS slave. This means that the user
LED PRG ENABLE autom. programming; LED green can use the PROFIBUS configuration tool to
LED ENERGY voltage ON; LED green specify what data will be transferred via the
LED PRJ MODE projecting mode active; LED yellow PROFIBUS. This makes it possible to adjust
LED U AS-i AS-Interface voltage; LED green the amount of data to be transferred via
Switch SET Selection and setting of a slave address PROFIBUS.
OK button Mode selection traditional-graphical/confirmation In addition, this gateway supports acyclical
Button MODE Mode selection PRJ-operation/save configuration/cursor

Safety at work
communication of the PROFIBUS DP V1.
ESC button Mode selection traditional-graphical/cancel These acyclical services can be used to
Electrical specifications access a mailbox in the gateway that provide
Insulation voltage Ui ≥ 500 V access to all the data that are made available
Rated operational voltage Ue from AS-Interface by the AS-Interface/PROFIBUS gateway.
Rated operational current Ie ≤ 180 mA from AS-Interface A push button can be used to accept the tar-
Interface get configuration and to adjust the PROFI-

Control cabinet
BUS address and baud rate. There are

I/O Modules
Protocol PROFIBUS
Interface type RS 485 7 LEDs on the front panel, showing the cur-
Transfer rate 9.6; 19.2; 44.44; 93.95; 187.5; 500; 1500 kBit/s self-synchro- rent status of the AS-Interface line.
nising In the case of the AS-Interface gateway with
Connection graphical display, the AS-Interface circuit can
PROFIBUS RS 485 interface be placed in service and the test of the con-
AS-Interface screw terminals nected periphery can be kept entirely sepa-

Field application
rate from the commissioning of the

I/O Modules
Ambient conditions
Ambient temperature 0 ... 55 °C (273 ... 328 K) PROFIBUS and the programming. On-site
Storage temperature -15 ... 75 °C (258 ... 348 K) operation with the aid of the graphical display
and 4 push buttons makes it possible to
Mechanical specifications
show all functions on the display that are
Protection degree Housing: IP40 according to DIN 40050
terminals: IP20 according to DIN 40050 covered by the AS-i Control Tools software

Analogue modules
Mass 420 g for other AS-Interface masters.
Construction type terminal rail housing, LDG-A-30
Accessories
Software
VAZ-SW-ACT32
The device is supplied with the configuration data files (GSD) as well as a restricted version of Full version of the AS-i Control Tools
the AS-i Control Tools software. The software performs the addressing, programming and
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available VAZ-PB-SIM

Other modules
as an accessory and features an expanded diagnostics monitor as well as a larger program PROFIBUS master simulator
memory for AS-Interface Control which makes it possible to detect faulty telegrams of slaves.
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby
the size of the I/O windows can be conveniently adapted to the AS-Interface circuit's load and
the AS-Interface configuration can be stored within the GSD file. A text file is also created,
which documents the status of AS-Interface data in the gateway's I/O window.

Inductive sensors
Note:
The VAZ-PB-SIM accessory is required for the AS-i Control Tool.

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 37
VBG-PB-G4F-R4

AS-Interface gateway VBG-PB-G4F-R4


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

DIP-
switch
Buttons
Field application

Mode Set
I/O Modules

Order code
AS-Interface + 7
VBG-PB-G4F-R4 8 PE
AS-Interface -
PROFIBUS gateway IP65 1 2 3 4 5
6
9 Screen
Analogue modules

6 7 8 9 10

. 2 Cage clamp
. 4 RxD/TxD-P terminal block
. µP
Features
1
• Gateway according to AS-Interface 3 RxD/TxD-N
specifikation 2.1 for up to 62 units
• AS-Interface connection via flat cable
Other modules

5 GND Power supply for


10
and EMS standard bottom section +5 V terminating resistor
(included delivery)
• Connection to PROFIBUS DP
• Acyclic communication in accordance
with PROFIBUS DP V1
Inductive sensors

• Commissioning, without PROFIBUS


communication
• All AS-Interface functions can be Indicating/operating means
called via PROFIBUS
• Power supply from AS-Interface E .
IV R IV
E
CT .ER i CT
R S A NF AS- -i A
Photoelectric

• PLC functionality PW BU CO U AS
sensors

• Error diagnostics via LEDs and LC


display
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

PRG ENABLE
• Parameterisation and monitor PRJ MODE
software
Rotary encoders

VBG-PB-G4F-R4
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
38 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-PB-G4F-R4
Technical data Function

Masters and
General specifications

Gateways
The VBG-PB-G4F-R4 is a complete PROFI-
AS-Interface specification V2.11
BUS slave with an IP67 rating designed for
Indicators/operating means use in the field. The G4 field housing of the
LED display, two-digit address display, error message PROFIBUS gateway offers all the advan-
LED BUS ACTIVE PROFIBUS master detected; LED green tages of the serial master in this design.
LED AS-i ACTIVE AS-Interface operation normal; LED green The VBG-PB-G4F-R4 is a modular PROFI-

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red BUS slave. This means that the user can use
LED PRG ENABLE autom. programming; LED green the PROFIBUS configuration tool to specify
LED ENERGY voltage ON; LED green what data will be transferred via the PROFI-
LED PRJ MODE projecting mode active; LED yellow BUS. This makes it possible to adjust the
LED U AS-i AS-Interface voltage; LED green amount of data to be transferred via PROFI-
Switch SET Selection and setting of a slave address BUS.
Button MODE Mode selection/save configuration In addition, this gateway supports acyclical

Safety at work
Electrical specifications communication of the PROFIBUS DP V1.
Insulation voltage Ui ≥ 500 V These acyclical services can be used to
Rated operational voltage Ue from AS-Interface access a mailbox in the gateway that provide
Rated operational current Ie ≤ 180 mA from AS-Interface access to all the data that are made available
Interface by the AS-Interface/PROFIBUS Gateway.
Protocol PROFIBUS Two push buttons are used for address
Interface type RS 485 assignment, acceptance of the desired con-

Control cabinet
figuration and for adjustment of the PROFI-

I/O Modules
Transfer rate 9.6 kBit/s ... 12 MBit/s self-synchronising
Connection BUS address and baud rate. In configuration
PROFIBUS Cable gland M16 x 1.5 and cage spring terminals mode, all detected AS-Interface slaves are
AS-Interface cable piercing technique displayed on the 2-digit LCD. In normal oper-
ation, the LCD is blank unless the master
Ambient conditions
detects a faulty AS-Interface slave. There are
Ambient temperature 0 ... 55 °C (273 ... 328 K)
7 LEDs on the front panel, showing the cur-

Field application
Storage temperature -25 ... 85 °C (248 ... 358 K)
rent status of the AS-Interface line.

I/O Modules
Mechanical specifications
Protection degree IP65 according to EN 60529
Mass approx. 355 g Accessories
VAZ-SW-ACT32
Software Full version of the AS-i Control Tools

Analogue modules
The device is supplied with the configuration data files (GSD) as well as a restricted version of
VAZ-PB-SIM
the AS-i Control Tools software. The software performs the addressing, programming and
PROFIBUS master simulator
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available
as an accessory and features an expanded diagnostics monitor as well as a larger program VAZ-G4-R4
memory for AS-Interface Control which makes it possible to detect faulty telegrams of slaves. Interface cable for direct connection of
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby
the master to a PC
the size of the I/O windows can be conveniently adapted to the AS-Interface circuit's load and

Other modules
the AS-Interface configuration can be stored within the GSD file. A text file is also created, U-G1P
which documents the status of AS-Interface data in the gateway's I/O window. Base for connection to round cable
Note: (EMS;
The VAZ-PB-SIM accessory is required for the AS-i Control Tool.
AS-Interface only)
VAZ-G4-B
Blind plug PG7

Inductive sensors
Note
U-G1F
base is included with delivery
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 39
VAG-PB-G4F-R4

AS-Interface gateway VAG-PB-G4F-R4


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work
Control cabinet

Electrical connection
I/O Modules

DIP-
switch
Buttons
Field application

Mode Set
I/O Modules

Order code
AS-Interface + 1
VAG-PB-G4F-R4 6 PE
AS-Interface -
PROFIBUS gateway IP65 1 2 3 4 5
2
7 Screen
Analogue modules

6 7 8 9 10

. 3 Cage clamp
. 8 RxD/TxD-P terminal block
. µP
Features
4
• AS-Interface certificate 9 RxD/TxD-N
• AS-Interface connection via flat cable
and EMS standard bottom section
Other modules

5 GND Power supply for


10
(included delivery) +5 V terminating resistor

• Protection degree IP65


• Voltage supply from AS-Interface
• Connection to PROFIBUS DP
Inductive sensors

• Commissioning, without PROFIBUS


communication
• All AS-Interface functions can be
called via PROFIBUS Indicating/operating means
• PLC functionality
E . E
IV R IV
• Error diagnostics via LEDs and LC CT .ER i CT
R S A NF AS- -i A
Photoelectric

display PW BU CO U AS
sensors

• Parameterisation and monitor


software
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

PRG ENABLE
PRJ MODE
Rotary encoders

VAG-PB-G4F-R4
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
40 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VAG-PB-G4F-R4
Technical data Function

Masters and
General specifications

Gateways
The VAG-PB-G4F-R4 is a complete PROFI-
AS-Interface specification V2.0
BUS slave designed for use in the field. The
Indicators/operating means G4 field housing of the PROFIBUS gateway
LED display, two-digit address display, error message offers all the advantages of the serial master
LED BUS ACTIVE PROFIBUS master detected; LED green in this design.
LED AS-i ACTIVE AS-Interface operation normal; LED green Two operating modes are available for the

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red exchange of data across PROFIBUS DP:
LED PWR voltage ON; LED green standard and expanded. In standard mode
LED PRG ENABLE autom. programming; LED green the gateway uses a fixed I/O configuration so
LED PRG MODE projecting mode active; LED yellow that it can be put into operation without addi-
LED U AS-i AS-Interface voltage; LED green tional parameter assignment. In expanded
Switch SET Selection and setting of a slave address mode the data structure can be optimised,
Button MODE Mode selection/save configuration enabling the user to define the data size sent

Safety at work
Electrical specifications to the PROFIBUS master. Owing to the
Insulation voltage Ui ≥ 500 V reduction of required data, less I/O space is
Rated operational voltage Ue from AS-Interface needed in the PLC. Two push buttons are
Rated operational current Ie ≤ 180 mA from AS-Interface used for address assignment, acceptance of
Interface the desired configuration, adjustment of the
Protocol PROFIBUS PROFIBUS address and baud rate. In config-
Interface type RS 485 uration mode, all detected AS-Interface

Control cabinet
slaves are displayed on the 2-digit LCD. In

I/O Modules
Transfer rate 9.6; 19.2; 44.44; 93.95; 187.5; 500; 1500 kBit/s self-synchro-
nising normal operation, the LCD is blank unless
Connection the master detects a faulty AS-Interface
PROFIBUS Cable gland M16 x 1.5 and cage spring terminals slave.There are 7 LEDs on the front panel,
AS-Interface cable piercing technique showing the current status of the AS-Inter-
Ambient conditions face line.

Field application
Ambient temperature 0 ... 55 °C (273 ... 328 K)
PLC Functionality

I/O Modules
Storage temperature -25 ... 85 °C (248 ... 358 K)
The VAG-PB-G4F-R4 provides 16 kByte pro-
Mechanical specifications
gram memory, 8 kByte RAM, 1024 counters
Protection degree IP65 according to EN 60529
and 1024 timers for PLC functionality. These
Mass 420 g
capacities suffice to process data on the AS-
Interface. Thus the master can also be oper-
Software

Analogue modules
ated in "stand-alone" mode. The program
The device is supplied with the configuration data files (GSD) as well as a restricted version of processing time is 2 ms per 1000 word com-
the AS-i Control Tools software. The software performs the addressing, programming and mands. The programming language is based
monitoring of the AS-Interface network. In addition, it contains an editor that creates programs on the STEP5 programming language. The
for the integrated PLC functionality. The full version of the AS-i Control Tools is available as AS-Interface CTRL functions (upload, down-
an accessory and features an expanded diagnostics monitor as well as a larger program load, start, stop, read and write internal
memory for AS-Interface Control which makes it possible to detect faulty telegrams of slaves. memory) are available in expanded mode.
A GSD file can be easily created for the PROFIBUS DP using the GSD assistant, whereby

Other modules
the size of the I/O windows can be conveniently adapted to the AS-Interface circuit's load and Accessories
the AS-Interface configuration can be stored within the GSD file. A text file is also created,
which documents the status of AS-Interface data in the gateway's I/O window. VAZ-SW-ACT32
Note: Full version of the AS-i Control Tools
The VAZ-PB-SIM accessory is required for the AS-i Control Tools.
VAZ-PB-SIM

Inductive sensors
PROFIBUS master simulator
VAZ-G4-R4
Interface cable for direct connection of
the master to a PC
U-G1P
Base for connection to round cable
Photoelectric

(EMS;
sensors

AS-Interface only)
VAZ-G4-B
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Blind plug PG7


Rotary encoders

Note
U-G1F
base is included with delivery
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 41
VAG-IBS-KF-FB

AS-Interface gateway VAG-IBS-KF-FB


Dimensions
Masters and
Gateways

80 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules

REMOTE IN connector
8
5 Screen
AS-Interface + 7
4 DO
Field application

AS-Interface - 6
DO
I/O Modules

29 5
AS-Interface + D1
30
Order code AS-Interface - 4
D1
41 3
AS-Interface + GND
VAG-IBS-KF-FB 42 2
AS-Interface - (nc)
1
INTERBUS gateway cabinet module µP Screen
.
Analogue modules

. REMOTE OUT connector


8
. Screen
7
DO
5 6
DO
Features Power Rail 4 5
D1
4
• Connection to the remote bus of the D1
3
GND
INTERBUS 2
RBST
1
• Voltage supply from AS-Interface
Other modules

Screen

• Programmable slave addresses


• Display of detected slaves
• Fault diagnosis
• Coded, removable terminals
Inductive sensors

• Integration into the INTERBUS "CMD


Tools" software
• Power Rail connection
Indicating/operating means

1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
Photoelectric
sensors

REMOTE REMOTE
UL BA IN OUT
8 8
CC TR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

7 7

CFG RBDA 6 6
Rotary encoders

U ASI MODE 5 5

4 4
ASI ACTIVE
3 3
PRG ENABLE
2 2
PRJ MODE SET
1 1

VAG-IBS-KF-FB
Accessories

25 26 27 28 29 30 31 32 33 34 35 36
37 38 39 40 41 42 43 44 45 46 47 48

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
42 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VAG-IBS-KF-FB
Technical data Function

Masters and
General specifications

Gateways
The INTERBUS is a bus system based on a
AS-Interface specification V2.0
ring topology which can be enhanced by the
Indicators/operating means AS-Interface/INTERBUS gateway. In contrast
LC display, two-digit address display, error message to INTERBUS, AS-Interface is topology inde-
LED TR PCP activity; LED green pendent and offers a very fast cycle time
LED RBDA Remote bus not available; LED red < 5 ms.

Extender, Repeaters
Power Supplies,
LED AS-i ACTIVE AS-Interface operation normal; LED green The VAG-IBS-KF-FB is a coupler between
LED PRG ENABLE autom. programming; LED green INTERBUS and AS-Interface. Both systems
LED PRG MODE projecting mode active; LED yellow are galvanically isolated from each other.The
LED U AS-i AS-Interface voltage; LED green VAG-IBS-KF-FB is a complete INTERBUS
LED UL operating voltage on INTERBUS side; LED green slave that uses 16 words and makes input
LED CC cable check; LED green and output data available for communica-
LED CFG configuration error; LED red tions. A bus terminal, like those connecting to
LED BA INTERBUS active; LED green

Safety at work
a peripheral bus are not required.
Switch SET Selection and setting of a slave address The VAG-IBS-KF-FB offers full AS-Interface
Button MODE Mode selection/save configuration master functionality. Parameters can be
Electrical specifications transmitted across one-word PCP channel to
Insulation voltage Ui ≥ 500 V the AS-Interface slave. Two push buttons are
Rated operational voltage Ue from AS-Interface used for address assignment of the AS-Inter-
Rated operational current Ie 200 mA face slaves and acceptance of the desired

Control cabinet
configuration. In configuration mode, all

I/O Modules
Interface
Protocol INTERBUS remote bus detected AS-Interface slaves are displayed
Interface type RS 485 on the 2-digit LCD. In normal operation, the
Connection LCD is blank unless the master detects a
AS-Interface removable coded terminals, Power Rail faulty AS-Interface slave.
INTERBUS two 8-pin MiniCombiCon connector There are seven LEDs on the front panel
used for diagnostics, while four LEDs indi-

Field application
Ambient conditions
cate communications on the INTERBUS.

I/O Modules
Ambient temperature 0 ... 55 °C (273 ... 328 K)
The KF cabinet housing has the same
Storage temperature -15 ... 70 °C (258 ... 343 K)
advantages as the serial master of this
Mechanical specifications
design.
Protection degree IP20 according to EN 60529 The gateway/AS-Interface is completely inte-
Mass 420 g grated with the INTERBUS software (CMD-

Analogue modules
Tools). Additional software is not required,
Software since the AS-Interface software ACT is inte-
grated and can be activated via the
No additional software is necessary for installation and monitoring since AS-i Control Tools is
INTERBUS.
completely integrated in the installation software of the INTERBUS (CMD Software).

Accessories
UPR-E

Other modules
End cap for UPR-03 und UPR-05
UPR-05
Universal Power Rail with DIN rail and
cover, 5 leads

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 43
VBG-IP-K5-DM

AS-Interface gateway VBG-IP-K5-DM


Dimensions
Masters and
Gateways

110 75
Extender, Repeaters
Power Supplies,

100
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application

+
I/O Modules

-
+
Order code - AS-Interface 1
.
VBG-IP-K5-DM µP .
.
Ethernet Gateway, double master for 2 +
- AS-Interface 2
AS-Interface networks +
Analogue modules

Plug-in jumpers -

Pos. 1
a
Features 24 V + –
0V -
• Gateway according to AS-Interface b –
specifikation 2.1 for up to 62 units Pos. 2
RJ-45 socket
• Connection to Ethernet TCP/IP
Other modules

Ethernet
Screen
• 1 IP address via boot-up
• 2 AS-Interface networks
• Commissioning, locally on the Using plug-in jumpers, it is possible to choose whether
gateway or via AS-i Control Tools the master shall be supplied by AS-Interface-1 circuit
Inductive sensors

software (pos.1) or via an own power pade (PELV) (pos. 2).

• All AS-Interface functions possible


via Ethernet
• MODBUS protocol as fieldbus Indicating/operating means
application layer
Photoelectric

AS-i 2 Made in Germany


sensors

ETHERNET VBG-IP-K5-DM
MODE
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

CONFIG ERROR
10 BASE-T
POWER
Rotary encoders

U AS-i

PRG ENABLE

PRJ MODE SET

AS-i 1 AS-i 2
+ - + - + - + - a 24V 0V b
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
44 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-IP-K5-DM
Technical data Function

Masters and
General specifications

Gateways
The VBG-IP-K5-DM is an Ethernet gateway
AS-Interface specification V2.11
for 2 parallel AS-i lines, which means that
Indicators/operating means the data of 2 AS-i lines can be transmitted
LED AS-i 2 assignment of display to AS-Interface strand 2; via an IP address. Each Ethernet gateway is
LED green
supplied with a unique MAC-ID. An IP
LC display, two-digit address display, error message
address can be assigned to the gateway by

Extender, Repeaters
LED ETHERNET ethernet active; LED green

Power Supplies,
means of this MAC-ID and Bootp.
LED CONFIG ERR configuration error; LED red
LED PRG ENABLE autom. programming; LED green
The design of the master is ideal for use in a
LED ENERGY voltage ON; LED green
cabinet.
LED PRJ MODE projecting mode active; LED yellow Two push buttons are used for address
LED U AS-i AS-Interface voltage; LED green assignment of the AS-Interface slaves and
Switch SET Selection and setting of a slave address acceptance of the desired configuration. In
Button MODE Mode selection/save configuration configuration mode, all detected AS-

Safety at work
Electrical specifications Interface slaves are displayed on the 2-digit
Insulation voltage Ui ≥ 500 V
LCD. In normal operation, the LCD is blank
Rated operational voltage Ue from AS-Interface or separately
unless the master detects a faulty AS-
Rated operational current Ie ≤ 200 mA from AS-Interface
Interface slave. There are 7 LEDs on the
front panel for rapid diagnostics.
Interface
Protocol Ethernet via TCP/IP

Control cabinet
Interface type 10 Base-T Accessories

I/O Modules
Transfer rate 10 MBit/s
Connection
VAZ-SW-ACT32
PROFIBUS RS 485 interface
Full version of the AS-i Control Tools
Ethernet RJ-45
AS-Interface screw terminals

Field application
Ambient conditions

I/O Modules
Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree Housing: IP40 according to DIN 40050
terminals: IP20 according to DIN 40050
Mass 420 g

Analogue modules
Construction type terminal rail housing, LDG-A-30

Software
The AS-i Control Tools software is supplied as restricted version together with the documen-
tation and performs the addressing, programming and monitoring of the AS-Interface net-
work. The full version of AS-i Control Tools is available as an accessory and features an
expanded diagnostics monitor as well as a larger program memory for AS-Interface Control

Other modules
which makes it possible to detect faulty telegrams of slaves.

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 45
VAG-MOD-KF-R4

AS-Interface gateway VAG-MOD-KF-R4


Dimensions
Masters and
Gateways

60 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

Order code
AS-Interface - 4
VAG-MOD-KF-R4 AS-Interface +
5

Modbus gateway cabinet module AS-Interface - 24


23
AS-Interface +
Analogue modules

33 Sub-D socket
AS-Interface - 3
32 A
AS-Interface + 8
B

Features 5
Power Rail 4
• Coded, removable terminals 25
A
26
B
• PLC functionality
35
Other modules

screen
• Two-digit LC display 36

• Power supply from MODBUS and


MODBUS
AS-Interface
• Programmable slave addresses
• Display of detected slaves
Inductive sensors

• Fault diagnosis
• Power Rail connection
Indicating/operating means

1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Photoelectric
sensors

POWER

BUS ACTIVE
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

CONFIG ERR

U ASI MODE
Rotary encoders

ASI ACTIVE

PRG ENABLE

PRJ MODE SET


RS 485
MODBUS
VAG-MOD-KF-R4
Accessories

19 20 21 22 23 24 25 26 27
28 29 30 31 32 33 34 35 36

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
46 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VAG-MOD-KF-R4
Technical data Function

Masters and
General specifications

Gateways
The VAG-MOD-KF-R4 is a MODBUS gate-
AS-Interface specification V2.0
way with PLC functionality. The design of this
Indicators/operating means master is ideal for use in a cabinet.Its hous-
LC display, two-digit address display, error message ing, only 60 mm wide, occupies little space in
LED BUS ACTIVE MODBUS interface in operation, LED green a cabinet installation. The VAG-MOD-KF-R4
LED AS-i ACTIVE AS-Interface operation normal; LED green is installed by snapping it onto the 35 mm

Extender, Repeaters
Power Supplies,
LED CONFIG ERR configuration error; LED red DIN Rail according to EN 50022, with the
LED PRG ENABLE autom. programming; LED green integrated Power Rail. The AS-Interface sig-
LED ENERGY voltage ON; LED green nal is transmitted via conductors, which are
LED PRG MODE projecting mode active; LED yellow integrated in the Power Rail. Thus all cabinet
LED U AS-i AS-Interface voltage; LED green modules in KF housing can be connected to
Switch SET Selection and setting of a slave address the AS-Interface cable by simply snapping
Button MODE Mode selection/save configuration them onto the DIN Rail. The AS-Interface

Safety at work
Electrical specifications data can be accessed in a binary format
Insulation voltage Ui ≥ 500 V (functions 1, 2, 5 and 15), or through the reg-
Rated operational voltage Ue from AS-Interface isters (functions 3, 4, 6 and 16). MODBUS
Rated operational current Ie ≤ 200 mA diagnostic registers are supported.
Interface The AS-Interface data can be used in various
Protocol MODBUS ways. Important data is available either
Interface type RS 485 packed or unpacked by means of the regis-

Control cabinet
ters or in the binary format. Thus the AS-

I/O Modules
Connection
AS-Interface removable coded terminals, Power Rail Interface masters with MODBUS slave inter-
MODBUS RS 485 interface face can be accessed by different MODBUS
masters and do not require large-scale adap-
Ambient conditions
tations. Power to the master is supplied by
Ambient temperature 0 ... 55 °C (273 ... 328 K)
the AS-Interface cable.
Storage temperature -15 ... 70 °C (258 ... 343 K)
Two push buttons are used for address

Field application
Mechanical specifications
assignment of the AS-Interface slaves and

I/O Modules
Protection degree IP20 acceptance of the desired configuration. In
Mass 420 g configuration mode, all detected AS-Interface
slaves are displayed on the 2-digit LCD. In
Software normal operation, the LCD is blank unless
the master detects a faulty AS-Interface
The AS-i Control Tools software is supplied as restricted version together with the documen-

Analogue modules
slave. There are 7 LEDs on the front panel,
tation. The software performs addressing, programming and monitoring of the AS-Interface
showing the current status of the AS-Inter-
network. In addition, it contains an editor that creates programs for the integrated PLC func-
face line.
tionality. The full version of the AS-i Control Tool is available as an accessory and features an
expanded diagnostics monitor as well as a larger program memory for AS-Interface Control
PLC Functionality
which makes it possible to detect faulty telegrams of slaves.
The VAG-MOD-KF-R4 has 16 kBytes of pro-
gram memory, 8 kBytes of main memory,
1024 counters and 1024 timers for the PLC

Other modules
functionality. These capacities suffice to
process data on the AS-Interface. Thus the
master can also be operated in "stand-alone"
mode. The program processing time is 2 ms
per 1000 word commands. The programming
language is based on the STEP5 program-

Inductive sensors
ming language.

Accessories
VAZ-SW-ACT32
Full version of the AS-i Control Tools
VAZ-R4-R2
Photoelectric

RS 232C/RS 485 converter


sensors

UPR-E
End cap for UPR-03 und UPR-05
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

UPR-05
Universal Power Rail with DIN rail and
Rotary encoders

cover, 5 leads
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 47
VBG-DN-K5-D

AS-Interface gateway VBG-DN-K5-D


Dimensions
Masters and
Gateways

110 75
Extender, Repeaters
Power Supplies,

100
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1


Field application
I/O Modules

Order code
VBG-DN-K5-D +
- .
+ AS-Interface + .
DeviceNet Gateway AS-Interface - µP .
-
Analogue modules

Features
• Gateway according to AS-Interface
specifikation 2.1 for up to 62 units CombiCon connector
1
• Power supply from DeviceNet and V+
Other modules

2
3
CAN_H
AS-Interface 4
screen
CAN_L
5
• Programmable slave addresses V-

• Display of detected slaves


• Fault diagnosis via LEDs and grafic
Inductive sensors

display
• Easy commissioning, by grafic
display
• AS-Interface monitor or extended AS- Indicating/operating means
Interface diagnostic read via display
Photoelectric
sensors

POWER MODE / VBG-DN-K5-D

MNS V+ 5
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
DeviceNet

CONFIG ERR OK
CAN_H 4
U AS-i
Rotary encoders

SHIELD 3
AS-i ACTIVE ESC

PRG ENABLE CAN_L 2

PRJ MODE SET / V- 1

AS-i 1
+ - + -
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
48 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-DN-K5-D
Technical data Function

Masters and
General specifications

Gateways
The VBG-DN-K5-D is a Gateway for the
AS-Interface specification V2.11
DeviceNet. The gateway is a 100 %
Indicators/operating means DeviceNet-Slave (Group 2 Slave) and as a
Display graphic display for addressing and error messages listed product can be addressed directly via
LED AS-i ACTIVE AS-Interface operation normal; LED green the DeviceNet device manager. Through col-
LED CONFIG ERR configuration error; LED red laboration with Allen-Bradley it is ensured,

Extender, Repeaters
Power Supplies,
LED PRG ENABLE autom. programming; LED green that the gateway has been fully integrated
LED ENERGY voltage ON; LED green into the DeviceNet software and can be sim-
LED PRJ MODE projecting mode active; LED yellow ply connected to an existing DeviceNet net-
LED U AS-i AS-Interface voltage; LED green work in the plug-and-play method.
LED MNS Module/net status; LED green/red Communication between the AS-Interface
Switch SET Selection and setting of a slave address and the DeviceNet is achieved via the gate-
OK button Mode selection traditional-graphical/confirmation way without additional programming
Button MODE Mode selection PRJ-operation/save configuration/cursor

Safety at work
expense. Connection of the AS-Interface
ESC button Mode selection traditional-graphical/cancel master to the DeviceNet is achieved via the
Electrical specifications 5-pin CombiCon connector in accordance
Insulation voltage Ui ≥ 500 V with the DeviceNet specification. Self-open-
Rated operational voltage Ue from AS-Interface ing screw terminals are available for all other
Rated operational current Ie DeviceNet ≤ 100 mA; connections.
AS-Interface ≤ 200 mA Addresses can be assigned to the AS-Inter-

Control cabinet
Interface face slaves and the set configuration can be

I/O Modules
Interface type DeviceNet accepted using the buttons provided.
Connection 7 LEDs, which are situated on the front
AS-Interface screw terminals panel, indicate the current status of the AS-
DeviceNet 5-pin CombiCon connector according to DeviceNet specifica- Interface network.
tion On the AS-Interface gateway with graphic
Ambient conditions display the commissioning of the AS-Inter-

Field application
face circuit and a test of the connected

I/O Modules
Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) peripherals can be completely separated
Mechanical specifications from the commissioning of the DeviceNet.
Protection degree Housing: IP40 according to DIN 40050 On site operation using the graphic display
terminals: IP20 according to DIN 40050 and the 4 buttons enable all functions to be
Mass 420 g represented on the display that are covered

Analogue modules
Construction type terminal rail housing, LDG-A-30 by the other AS-Interface masters via the
AS-i Control Tools software.
Software
The device is supplied with the configuration data files (EDS) as well as a restricted version of Accessories
the AS-i Control Tools software. The software performs the addressing, programming and VAZ-DN-SIM
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available DeviceNet master simulator
as an accessory and features a larger program memory for AS-i Control as well as an

Other modules
expanded diagnostics monitor, which makes it possible to detect faulty telegrams of slaves.
Note:
The VAZ-DN-SIM accessory is required for the AS-i Control Tool.

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 49
VBG-DN-K5-DMD

AS-Interface gateway VBG-DN-K5-DMD


Dimensions
Masters and
Gateways

110 75
Extender, Repeaters
Power Supplies,

100
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

+
Field application

-
I/O Modules

+
- AS-Interface 1
Order code .
.
µP .
VBG-DN-K5-DMD
+
- AS-Interface 2
DeviceNet Gateway, double master for
+
2 AS-Interface networks -
Analogue modules

Plug-in jumpers
Pos. 1
a
24 V +
Features 0V -
b CombiCon connector
• Gateway according to AS-Interface 1
Pos. 2 V+
specifikation 2.1 for up to 62 units 2
CAN_H
3
4
screen
• 2 AS-Interface networks
Other modules

CAN_L
5 V-
• Power supply from DeviceNet and
AS-Interface
• Programmable slave addresses
Using plug-in jumpers, it is possible to choose whether the
• Display of detected slaves master shall be supplied by AS-Interface-1 circuit (pos.1)
Inductive sensors

or via an own power pade (PELV) (pos. 2).


• Fault diagnosis via grafic display

Indicating/operating means
Photoelectric
sensors

POWER MODE / VBG-DN-K5-DMD

MNS V+ 5
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
DeviceNet

CONFIG ERR OK
CAN_H 4
U AS-i
Rotary encoders

SHIELD 3
AS-i ACTIVE ESC

PRG ENABLE CAN_L 2

PRJ MODE SET / V- 1

AS-i 1 AS-i 2 PWR CONFIG


+ - + - + - + - a 24V 0V b
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
50 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-DN-K5-DMD
Technical data Function

Masters and
General specifications

Gateways
The VBG-DN-K5-DMD is a DeviceNet gate-
AS-Interface specification V2.11
way with 2 AS-Interface master according to
Indicators/operating means the AS-Interface specification 2.11. The
Display graphic display for addressing and error messages design is very suitable for use in the switch
LED AS-i ACTIVE AS-Interface operation normal; LED green cabinet.
LED CONFIG ERR configuration error; LED red The gateway is a 100 % DeviceNet slave

Extender, Repeaters
Power Supplies,
LED PRG ENABLE autom. programming; LED green (group 2 slave) and can be configured using
LED ENERGY voltage ON; LED green DeviceNet Manager. Owing to the coopera-
LED PRJ MODE projecting mode active; LED yellow tion with Allen-Bradley, the gateway was
LED U AS-i AS-Interface voltage; LED green completely integrated with the DeviceNet
LED MNS Module/net status; LED green/red software, and can be easily connected to an
Switch SET Selection and setting of a slave address existing DeviceNet network.
OK button Mode selection traditional-graphical/confirmation The gateway enables communication
Button MODE Mode selection PRJ-operation/save configuration/cursor

Safety at work
between the AS-Interface and the Device-
ESC button Mode selection traditional-graphical/cancel Net, without additional programming. The
Electrical specifications AS-Interface master is connected to Device-
Insulation voltage Ui ≥ 500 V Net with a 5-pin CombiCon connector in
Rated operational voltage Ue from AS-Interface accordance with the DeviceNet specifica-
Rated operational current Ie DeviceNet ≤ 100 mA; tions. Self-opening device terminals for leads
AS-Interface ≤ 200 mA are available for all other connections.

Control cabinet
Interface The push buttons are used for address

I/O Modules
Interface type DeviceNet assignment of the AS-Interface slaves and
Connection acceptance of the desired configuration.
AS-Interface screw terminals There are 7 LEDs on the front panel, show-
DeviceNet 5-pin CombiCon connector according to DeviceNet specifica- ing the current status of the AS-Interface line.
tion In the case of the AS-Interface Gateway with
Ambient conditions graphical display, the AS-Interface circuit can

Field application
be placed in service and the test of the con-

I/O Modules
Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -15 ... 70 °C (258 ... 343 K) nected periphery can be kept entirely sepa-
Mechanical specifications rate from the commissioning of the
Protection degree Housing: IP40 according to DIN 40050 DeviceNet. On-site operation with the aid of
terminals: IP20 according to DIN 40050 the graphical display and 4 push buttons
Mass 420 g makes it possible to show all functions on the

Analogue modules
Construction type terminal rail housing, LDG-A-30 display that are covered by the AS-i Control
Tools software for other AS-Interface mas-
Software ters.

The device is supplied with the configuration data files (EDS) as well as a restricted version of
the AS-i Control Tools software. The software performs the addressing, programming and Accessories
monitoring of the AS-Interface network. The full version of the AS-i Control Tool is available VAZ-DN-SIM
as an accessory and features a larger program memory for AS-i Control as well as an DeviceNet master simulator

Other modules
expanded diagnostics monitor, which makes it possible to detect faulty telegrams of slaves.
Note:
The VAZ-DN-SIM accessory is required for the AS-i Control Tool.

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 51
VBG-CAN-K5-D

AS-Interface gateway VBG-CAN-K5-D


Dimensions
Masters and
Gateways

110 75
Extender, Repeaters
Power Supplies,

100
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application
I/O Modules

Order code
VBG-CAN-K5-D +
- .
+ AS-Interface + .
CANopen Gateway AS-Interface - µP .
-
Analogue modules

Features
• Gateway according to AS-Interface
specifikation 2.1 for up to 62 units CombiCon connector
1
• Protocol standard: CANopen (nc)
Other modules

2
3
CAN_H
screen
• Voltage supply from AS-Interface 4
CAN_L
5 (nc)
• Programmable slave addresses
• Display of detected slaves
• Fault diagnosis via LEDs and grafic
Inductive sensors

display
• Easy commissioning, by grafic
display
Indicating/operating means
• AS-Interface monitor or extended AS-
Interface diagnostic read via display
Photoelectric
sensors

POWER MODE / VBG-CAN-K5-D

MNS V+ 5
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
CANopen

CONFIG ERR OK
CAN_H 4
U AS-i
Rotary encoders

SHIELD 3
AS-i ACTIVE ESC

PRG ENABLE CAN_L 2

PRJ MODE SET / V- 1

AS-i
+ - + -
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
52 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-CAN-K5-D
Technical data Function

Masters and
General specifications

Gateways
The VBG-CAN-K5-D is a gateway to a
AS-Interface specification V2.11
CANopen network. The gateway acts as a
Indicators/operating means 128 bit digital I/O module. All mandatory
Display graphic display for addressing and error messages functions, as well as interrupts and 8 bit
LED AS-i ACTIVE AS-Interface operation normal; LED green groups etc. are implemented. An emergency
LED CONFIG ERR configuration error; LED red message can be activated in the case of an

Extender, Repeaters
Power Supplies,
LED PRG ENABLE autom. programming; LED green AS-Interface configuration error.
LED ENERGY voltage ON; LED green The AS-Interface master is connected to
LED PRJ MODE projecting mode active; LED yellow CANopen with a 5-pin CombiCon connector
LED U AS-i AS-Interface voltage; LED green in accordance with the DeviceNet specifica-
LED MNS Module/net status; LED green/red tions. Self-opening device terminals for leads
Switch SET Selection and setting of a slave address are available for all other connections.
OK button Mode selection traditional-graphical/confirmation The push buttons are used for address
Button MODE Mode selection PRJ-operation/save configuration/cursor

Safety at work
assignment of the AS-Interface slaves and
ESC button Mode selection traditional-graphical/cancel acceptance of the desired configuration.
Electrical specifications There are 7 LEDs on the front panel, show-
Insulation voltage Ui ≥ 500 V ing the current status of the AS-Interface line.
Rated operational voltage Ue from AS-Interface In the case of the AS-Interface Gateway with
Rated operational current Ie ≤ 200 mA graphical display, the AS-Interface circuit can
Interface be placed in service and the test of the con-

Control cabinet
nected periphery can be kept entirely sepa-

I/O Modules
Interface type CANopen
Connection rate from the commissioning of the
AS-Interface screw terminals DeviceNet. On-site operation with the aid of
DeviceNet 5-pin CombiCon connector according to DeviceNet specifica- the graphical display and 4 push buttons
tion makes it possible to show all functions on the
Ambient conditions display that are covered by the AS-i Control
Tools software for other AS-Interface mas-

Field application
Ambient temperature 0 ... 55 °C (273 ... 328 K)
ters.

I/O Modules
Storage temperature -15 ... 70 °C (258 ... 343 K)
Mechanical specifications
Protection degree Housing: IP40 according to DIN 40050
terminals: IP20 according to DIN 40050
Mass 420 g
Construction type terminal rail housing, LDG-A-30

Analogue modules
Software
No additional software is required.

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 53
VBG-CCL-G4F

AS-Interface gateway VBG-CCL-G4F


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

Buttons
Field application
I/O Modules

Mode Set

Order code AS-Interface +

VBG-CCL-G4F AS-Interface -

CC Link Gateway IP65 1


1 2 3 4 5
6 FG
Analogue modules

. 6 7 8 9 10
. 2
. µP 7 SLD Cage clamp
terminal block
Features
3
• Gateway according to AS-Interface 8 DG

specifikation 2.1 for up to 62 units


4
• AS-Interface connection via flat cable DA
Other modules

9
Terminating resistor
and EMS standard bottom section (remove, unless last
(included delivery) 5 CC-lInk module)
10 DB
• Protection degree IP65
• Voltage supply from AS-Interface
Inductive sensors

• PLC functionality
• Error diagnostics via LEDs and LC
display
Indicating/operating means
Photoelectric

R UN RR
PW L R L E SD RD
sensors

i
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

RR S- IVE LE DE
F. E U A CT AB MO
N
N -i A E RG
CO AS RG P
P
Rotary encoders

VBG-CCL-G4F
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
54 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface gateway VBG-CCL-G4F
Technical data Function

Masters and
General specifications

Gateways
The VBG-CCL-G4F is a complete CC-Link
AS-Interface specification V2.11
master for use in the field (IP65). The gate-
Indicators/operating means way's G4 field housing has the same advan-
LC display, two-digit address display, error message tages as the serial master in this design.
LED SD CC Link send data; LED green Two buttons are used for address assign-
LED RD CC Link receive data; LED green ment of the AS-Interface slaves and accept-

Extender, Repeaters
Power Supplies,
LED AS-i ACTIVE AS-Interface operation normal; LED green ance of the desired configuration. In
LED CONFIG ERR configuration error; LED red configuration mode, all detected AS-Interface
LED PWR voltage ON; LED green slaves are displayed on the 2-digit LCD. In
LED L RUN CC link in operation; LED green normal operation, the LCD is blank unless
LED L ERR CC Link error; LED red the master detects a faulty AS-Interface
LED PRG ENABLE autom. programming; LED green slave. The LEDs, located on the front panel,
LED PRG MODE projecting mode active; LED yellow show the current status of the AS-i line.
LED U AS-i AS-Interface voltage; LED green

Safety at work
Switch SET Selection and setting of a slave address PLC Functionality
Button MODE Mode selection/save configuration The VBG-CCL-G4F provides 16 kBytes of
Electrical specifications program memory, 8 kBytes of main memory,
Insulation voltage Ui ≥ 500 V 1024 counters and 1024 timers for PLC func-
Rated operational voltage Ue from AS-Interface tionality. These capacities suffice to process
Rated operational current Ie ≤ 200 mA from AS-Interface the data on the AS-Interface. Thus the mas-

Control cabinet
ter can also be operated in "stand-alone"

I/O Modules
Interface
Protocol according to CC-Link specification mode. The program processing time is 2 ms
Interface type remote device, 3 occupied stations per 1000 word commands. The programming
Transfer rate 156 kBit/s up to 10 MBit/s language is based on the STEP5 program-
Connection ming language. The AS-Interface CTRL
AS-Interface cable piercing technique functions (upload, download, start, stop, read
or write internal memory) are available in

Field application
CC Link Cable gland M16 x 1.5 and cage spring terminals
expanded mode.

I/O Modules
Ambient conditions
Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) Accessories
Mechanical specifications
U-G1P
Protection degree IP65 according to EN 60529
Base for connection to round cable
Mass 355 g

Analogue modules
(EMS;
Software AS-Interface only)

No additional software is required. VAZ-G4-B


Blind plug PG7

Note

Other modules
U-G1F
base is included with delivery

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 55
AS-Interface - Power Supplies, Power Extenders and Repeaters
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
I/O Modules - Field I/O Modules - Control
application
Analogue modules
Other modules cabinet
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
56 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Power Supplies, Power Extenders and Repeaters

3 Power Supplies, Power Extend-

Masters and
Gateways
ers and Repeaters
On the AS-lnterface data and power supply are transferred on only
2 conductors. Data communication is based on an AC current supply, while

Extender, Repeaters
Power Supplies,
the power supply is DC (29.5 ... 31.6 V). In this respect a power pack with
a decoupling network is required for the AS-Interface power supply. All pow-
er packs satisfy the PELV (Protective Extra Low Voltage) requirements of
EN 50178 and EN 60204, so that a protective conductor (PE) is not re-
quired for the AS-Interface circuit. Since the AS-Interface has a symmetrical
design, the system ground should be connected to the shield terminal on

Safety at work
the power pack.
To increase system safety an earth fault monitor function is integrated in
some power packs. This reliably signals any irregularity in the contact be-
tween the AS-Interface cable and the earth potential. Whilst on the one

I/O Modules - Field I/O Modules - Control


hand such a fault can lead to a breakdown of AS-Interface communication,
two earth faults can lead to the uncommanded operation of a plant item,

cabinet
which can then no longer be switched off by the system. This must be pre-
vented in accordance with EN 60204. A method, which can be employed
here, is to arrange for the AS-Interface network to be switched off on detec-
tion of an earth fault.
Depending on the size of the system, power packs providing between 2.4 A

application
and 8 A can be inserted at any point in the AS-Interface network. For dual
masters, there are also corresponding dual power supplies available. If par-
ticularly large consumers are present, the power supplies should be placed
in their vicinity.

Analogue modules
AS-Interface Segment 1

Other modules
Gateway
Segment 2

Repeater

Inductive sensors
AS-Interface AS-Interface
power supply power supply
Switch cabinet In field
Photoelectric

If this is not possible, for example due to the protection class required, then
sensors

the master can be used as a field device, together with a series-connected


power extender. By this means the length of cable between the power
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

pack and the power extender does not count as part of the AS-Interface net-
work length and in this way a number of AS-Interface networks, each with
Rotary encoders

a master and series-connected power extender, can be supplied by a single


power pack.
At least 28 V must be applied to the power extender to ensure that it func-
tions. The sum of the input currents to the AS-Interface stations must be
less than the maximum output current of the power pack. In the case of the
modules the current consumption comprises the following: Operating cur-
Accessories

rent, current consumption of the sensors supplied by the AS-Interface, plus


the current needed to drive the outputs, if these are not externally supplied.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 57
AS-Interface - Power Supplies, Power Extenders and Repeaters
The AS-Interface cable does not have to be grounded, as stated above,
grounded fault monitoring is integrated in a number of power packs. Option-
Masters and
Gateways

ally, the occurrence of a ground fault can simply be signalled, or used to


switch off the AS-Interface network.
Extender, Repeaters

Field bus
Power Supplies,

PLC
AS-Interface
Safety at work

0VD Gateway

Standard Power Extender


I/O Modules - Field I/O Modules - Control

power supply
cabinet

Switch
Schaltschrank
cabinet Im
In field
Feld

With a repeater, which can be used in any arbitrary branch, the AS-Inter-
face network can be extended to more than 100 m in length by means of
application

signal amplification. There is no limit on the number of repeaters in the net-


work, but the maximum number of repeaters which can be placed one after
the other in the circuit is two, i.e. the maximum distance between the master
and the last slave is 300 m. If safe slaves are used only one repeater can
be inserted between the master or monitor and a safe slave. The repeater
Analogue modules

also provides galvanic isolation between the networks. Therefore it is al-


ways necessary to incorporate an additional AS-Interface power pack or a
power extender after the repeater.

100 m
Other modules

100 m
100 m

Gateway
Repeater Repeater
Inductive sensors

AS-Interface
AS-Interface power supply
power supply
100 m
100 m
AS-Interface
power supply
Photoelectric
sensors

Repeater Repeater
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface
AS-Interface power supply
power supply
Rotary encoders

Switch cabinet In field


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
58 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Power Supplies, Power Extenders and Repeaters
3.1 Overview of power supplies, power extenders, and repeaters

Masters and
Gateways
Type code Nominal voltage Output voltage Output current Page

Extender, Repeaters
Power Supplies,
VAN-115/230AC-K17 90 ... 265 V AC 29.5 ... 31.6 V DC 4A 60

Safety at work
VAN-115/230AC-K13-EFD 100 ... 240 V AC 29.5 ... 31.6 V DC 2,4A 62

I/O Modules - Field I/O Modules - Control


VAN-115/230AC-K14-EFD 100 ... 240 V AC 29.5 ... 31.6 V DC 4,8A 64

cabinet
115 V AC/230 V AC

application
VAN-115/230AC-K16 29.5 ... 31.6 V DC 8A 66
switchable

Analogue modules
115 V AC/230 V AC
VAN-115/230AC-K7-DN 29.5 ... 31.6 V DC 2x4A 68
switchable

Other modules
VAN-115/230AC-K8 115 ... 230 V AC 29.5 ... 31.6 V DC 2,8A 70

Inductive sensors
VAN-24DC-K6 24 V DC 29.5 ... 31.6 V DC 3A 72
Photoelectric
sensors

VAN-G4-PE 30 V DC 29.5 ... 31.6 V DC 2,8A 74


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

VAR-G4F Repeater 76
Accessories

VAR-KE2 Repeater 78

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 59
VAN-115/230AC-K17

AS-Interface power supply VAN-115/230AC-K17


Dimensions
Masters and
Gateways

70 129
Extender, Repeaters
Power Supplies,

126
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

Order code
VAN-115/230AC-K17
L AS-Interface +
AS-Interface power supply (V in)
D
E
Analogue modules

D C
A O
T U Ground
P (screen)
Features A
L
LED I
• 4 A output loading
N
• 90 V AC bis 265 V AC wide range N G
(GND in) AS-Interface -
power pack
Other modules

• SELV
• LED operating display PE

• AS-Interface data decoupling


• Power factor correction
Inductive sensors

Indicating/operating means
Photoelectric
sensors

PE
PE
N Ue -
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

L
Ue +

LED Power
Rotary encoders

LED Overload

AS-i - AS-Interface - (brown)

AS-i + AS-Interface + (blue)


Ground
Screen
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
60 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-115/230AC-K17
Technical data Function

Masters and
Indicators/operating means

Gateways
The primarily pulsed power pack has been
LED Overload Red LED, flashing
designed for field bus applications which
LED PWR LED green
transmit power and data via one single two-
Electrical specifications wire cable (AS-Interface concept). It supplies
Capacity factor approx. 0.6 (Depending on input voltage) a fully extended AS-Interface system with a
Mains frequency 47 ... 63 Hz 4 A output current. Sinusoidal current drain

Extender, Repeaters
Power Supplies,
Efficiency approx. 85 % from the mains avoids harmonics. The power
Rated operational voltage Ue 90 ... 265 V AC factor correction feature ensures that the cur-
Rated operational current Ie approx. 0.6 A (Without reactive current) rent and the voltage are almost cophasal to
Ripple according to AS-Interface specification avoid reactive power and provide a
Output cos ϕ > 0.97 power factor.
Current limit approx. 4.5 A The power pack makes available electric
Current 4A power. In addition to this, it provides for data

Safety at work
Voltage 29.5 ... 31.6 V DC isolation towards the power source and bal-
Standard conformity ancing of the two output lines (AS-Interface +
Standards EN 60950, UL 60950 planned, AS-Interface certificate planned and AS-Interface -) towards the reference
Ambient conditions potential of the machine (shield connection).
Ambient temperature -10 ... 60 °C (263 ... 333 K) Precise transformer coupling allows the use
Storage temperature -40 ... 85 °C (233 ... 358 K) of unshielded load lines.
Mechanical specifications

Control cabinet
Fuses:

I/O Modules
Protection degree IP20
The power pack is electronically protected
against external short circuits. In case of
Notes fault, the internal fusible link separates the
The "GND" spring-loaded terminal must be connected to the potential of the machine in any power pack from the mains.
case.

Field application
This AS-Interface Power Supply does not provide insulation monitoring according to

I/O Modules
EN 61557-8.

Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 61
VAN-115/230AC-K13-EFD

AS-Interface power supply VAN-115/230AC-K13-EFD


Dimensions
Masters and
Gateways

60 110
Extender, Repeaters
Power Supplies,

135
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application

EFD
I/O Modules

Order code
L D AS-Interface +
VAN-115/230AC-K13-EFD E
C
AS-Interface power supply D
O
A
U
Analogue modules

EFD T GND
A P
L
I
Features N
G AS-Interface -
• AS-Interface certificate N Auxiliary Power
• PELV + -
Other modules

PE 13 (+)
• LED operating display
EFD
• 2.4 A output load switch
output
• 115 V AC to 230 V AC 14
• AS-Interface filter integrated
• Power factor correction
Inductive sensors

• Earh fault detection

Indicating/operating means
Photoelectric
sensors

N
L
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Reset button
Press briefly (< 2 sec.) - Earth fault simulation
Reset
Press long (> 2 sec.) - Reset of earth fault indication
Rotary encoders

LED-EFD
LED-Dc o.k.
AS-Interface +
GND
AS-Interface - EFD-switch output
13(+)
14
Earth fault detection-selector switch
Accessories

EFD ext. - Earth fault only signalled


EFD int. - Earth fault switches off power pack

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
62 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-115/230AC-K13-EFD
Technical data Function

Masters and
Indicators/operating means

Gateways
The primary switched-mode power supply
Reset push button switch earth fault simulation/reset of earth fault display
unit was designed for field bus applications,
Ground fault monitor selection switch int: Switch-off of power supply for earth fault
which transmit both energy and data via a
ext: no switch-off with earth fault
two-wire cable (AS-Interface design). It pro-
LED PWR operating display; LED green
flashing: overload vides power to a fully developed AS-Interface
system with an output current of 2.4 A. The

Extender, Repeaters
LED EFD earth fault display; LED red

Power Supplies,
Electrical specifications sinusoidal draw of current from the mains
Capacity factor approx. 0.95
power prevents harmonics. The powerfactor
Mains frequency 47 ... 63 Hz
correction ensures that the current is in
Efficiency approx. 88 %
phase with the voltage, so the capacity factor
Rated operational voltage Ue nominal: 100 ... 240 V AC
of cos ϕ > 0.97 prevents reactive power.
permissible: 85 ... 265 V AC In this case, the power supply unit provides
Rated operational current Ie approx. 0.5 A the energy, decouples data of the power

Safety at work
Ripple according to AS-Interface specification source and balances the two output cables
Output (AS-Interface + and AS-Interface -) in rela-
Current limit 3.8 A
tion to ground (screen connection). The pre-
Current 2.4 A
cise and transformer coupling permits the
Voltage 29.5 ... 31.6 V DC
use of unshielded load lines.
Ambient conditions
Fuse:

Control cabinet
Ambient temperature -25 ... 60 °C (248 ... 333 K)
The power supply unit is electronically pro-

I/O Modules
Storage temperature -40 ... 85 °C (233 ... 358 K)
tected against external short circuits. In case
Mechanical specifications of a defect, the internal fuse disconnects the
Protection degree IP20 according to EN 60529 power supply unit from the supply.

Notes Earth Fault Detection EFD:


The switch output of the earth fault detection

Field application
The spring terminal "GND" must be connected to ground. Otherwise, earth faults cannot be
is used for evaluating the detected earth fault

I/O Modules
detected. Owing to the passive measuring principle, only asymmetric insulation faults can be
in the AS-Interface system. By means of the
detected. Equal insulation faults of the "AS-Interface +"- and "AS-Interface -" cables to earth
potential free transistor output, the system
are not detected.
can be stopped directly via the control pro-
This AS-Interface power supply does not represent an insulation monitoring in accordance
gram. The output which is normally closed, is
with EN 61557-8.
opened permanently due to detection of an

Analogue modules
earth fault. An earth fault is also signalled by
means of the "EFD" LED. The output does
not close again until the power supply is
restarted or the reset button is pressed
(> 2 seconds). The transistor output is
reverse-polarity protected and can be loaded
to a maximum of 150 mA. The earth fault
detection can also be configured so that the

Other modules
power supply disconnects automatically
when an earth fault is detected in the AS-
Interface system. This setting can be acti-
vated by means of the selector switch,
located on the lower side of the device.

Inductive sensors
Check of the earth fault detection:
To simulate an earth fault in the device, the
reset button is pressed for less than
2 seconds. This makes it possible to test the
earth fault detection and evaluation, the sig-
nalling as well as the switch output at regular
intervals. To reset the earth fault, the reset
button is pressed again for more than
Photoelectric

2 seconds.
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 63
VAN-115/230AC-K14-EFD

AS-Interface power supply VAN-115/230AC-K14-EFD


Dimensions
Masters and
Gateways

113.5 110
Extender, Repeaters
Power Supplies,

135
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application

EFD
I/O Modules

Order code
L D AS-Interface +
VAN-115/230AC-K14-EFD E
C
AS-Interface power supply D
O
A
U
Analogue modules

EFD T GND
A P
L
I
Features N
G AS-Interface -
• AS-Interface certificate N Auxiliary Power
• PELV + -
Other modules

PE 13 (+)
• LED operating display
EFD
• 4.8 A output load switch
output
• 115 V AC to 230 V AC 14
• AS-Interface filter integrated
• Power factor correction
Inductive sensors

• Earh fault detection

Indicating/operating means
Photoelectric
sensors

N
L
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Reset button
Press briefly (< 2 sec.) - Earth fault simulation
Reset Press long (> 2 sec.) - Reset of earth fault indication
Rotary encoders

LED-EFD
LED-DC o.k.
AS-Interface +
GND
AS-Interface - EFD-switch output
13(+)
14
Earth fault detection-selector switch
Accessories

EFD ext. - Earth fault only signalled


EFD int. - Earth fault switches off power pack

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
64 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-115/230AC-K14-EFD
Technical data Function

Masters and
Indicators/operating means

Gateways
The primary switched-mode power supply
Reset push button switch earth fault simulation/reset of earth fault display
unit was designed for field bus applications,
Ground fault monitor selection switch int: Switch-off of power supply for earth fault
which transmit both energy and data via a
ext: no switch-off with earth fault
two-wire cable (AS-Interface design). It pro-
LED PWR operating display; LED green
flashing: overload vides power to a fully developed AS-Interface
system with an output current of 4.8 A. The

Extender, Repeaters
LED EFD earth fault display; LED red

Power Supplies,
Electrical specifications sinusoidal draw of current from the mains
Capacity factor approx. 0.95
power prevents harmonics. The powerfactor
Mains frequency 47 ... 63 Hz
correction ensures that the current is in
Efficiency approx. 88 %
phase with the voltage, so the capacity factor
Rated operational voltage Ue nominal: 100 ... 240 V AC
of cos ϕ > 0.97 prevents reactive power.
permissible: 85 ... 265 V AC In this case, the power supply unit provides
Rated operational current Ie approx. 0.7 A the energy, decouples data of the power

Safety at work
Ripple according to AS-Interface specification source and balances the two output cables
Output (AS-Interface + and AS-Interface -) in rela-
Current limit approx. 7.6 A
tion to ground (screen connection). The pre-
Current 4.8 A
cise and transformer coupling permits the
Voltage 29.5 ... 31.6 V DC
use of unshielded load lines.
Switch-on delay ton < 2000 ms
Fuse:
Ambient conditions

Control cabinet
The power supply unit is electronically pro-

I/O Modules
Ambient temperature -25 ... 60 °C (248 ... 333 K)
tected against external short circuits. In case
Storage temperature -40 ... 85 °C (233 ... 358 K)
of a defect, the internal fuse disconnects the
Mechanical specifications power supply unit from the supply.
Protection degree IP20 according to EN 60529
Mass 1000 g Earth Fault Detection EFD:
The switch output of the earth fault detection

Field application
Notes is used for evaluating the detected earth fault

I/O Modules
in the AS-Interface system. By means of the
The spring terminal "GND" must be connected to ground. Otherwise, earth faults cannot be
potential free transistor output, the system
detected. Owing to the passive measuring principle, only asymmetric insulation faults can be
can be stopped directly via the control pro-
detected. Equal insulation faults of the "AS-Interface +"- and "AS-Interface -" cables to earth
gram. The output which is normally closed, is
are not detected.
opened permanently due to detection of an
This AS-Interface power supply does not represent an insulation monitoring in accordance

Analogue modules
earth fault. An earth fault is also signalled by
with EN 61557-8.
means of the "EFD" LED. The output does
not close again until the power supply is
restarted or the reset button is pressed
(> 2 seconds). The transistor output is
reverse-polarity protected and can be loaded
to a maximum of 150 mA. The earth fault
detection can also be configured so that the

Other modules
power supply disconnects automatically
when an earth fault is detected in the AS-
Interface system. This setting can be acti-
vated by means of the selector switch,
located on the lower side of the device.

Inductive sensors
Check of the earth fault detection:
To simulate an earth fault in the device, the
reset button is pressed for less than
2 seconds. This makes it possible to test the
earth fault detection and evaluation, the sig-
nalling as well as the switch output at regular
intervals. To reset the earth fault, the reset
button is pressed again for more than
Photoelectric

2 seconds.
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 65
VAN-115/230AC-K16

AS-Interface power supply VAN-115/230AC-K16


Dimensions
Masters and
Gateways

102
91 93
Extender, Repeaters
Power Supplies,

Overload
Reset

62
124
Output IR on
DC 30.5V / 8A 1

62
1-2 Communication mode 2
Input 2-3 IR addressing mode
Safety at work

3
AC 115/230V AS-int
6.0/2.8A 50-60Hz ok
N L + - + - Shield

5 11 5

4
Control cabinet

Electrical connection
I/O Modules

Mode Selector:
Communication/
Field application

IR Addressing
I/O Modules

Order code L DC AS-Interface +


V
VAN-115/230AC-K16 N DC
Shield
Transient- Input Rectifier AS-Interface Infrared (IR)
AS-Interface power supply Inrush- and and Hold-up DC to DC Decoupling Addressing AS-Interface -
EMC- Filter Capacitor Converter Network Mode
Analogue modules

AS-i ok IR on
Features
• AS-Interface certificate
• PELV/SELV
Other modules

• LED operating display


• 8 A Output loading
• 115 V AC / 230 V AC switchable
• AS-Interface data decoupling
• Overload protection using FUSE
Inductive sensors

mode

Indicating/operating means
Photoelectric

LED red:
Flashes in fuse mode
sensors

115/230V switch: Scanner:


Sliding switch for Reset fuse mode
selection of the input
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

voltage range Overload


Reset LED red:
ON: pos. plug-in jumper 2-3
OFF: pos. plug-in jumper 1-2
Rotary encoders

Plug-in jumper:
Pos. 1-2: regular AS-Interface communication
Pos. 2-3: data communication interrupted
Output IR on IR addressing can be effected
DC 30.5V / 8A 1
1-2 Communication mode 2
Input
AC 115/230V
2-3 IR addressing mode
3 LED green:
AS-int
6.0/2.8A 50-60Hz ok ON: AS-Interface voltage in the permissible range
N L + - + - Shield
OFF: overload or missing supply voltage
Connection terminals
input
Accessories

Connection terminals output


Double terminals for AS-Interface + and AS-Interface -
machine earth (PE)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
66 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-115/230AC-K16
Technical data Function

Masters and
Indicators/operating means

Gateways
The primary pulsed DIN rail power pack is
Reset push button switch FUSE mode reset
used for special power supply of AS-Inter-
Mains power selection switch changeover switch for 115 V AC/230 V AC
face networks via a two-wire line. It supplies
LED Overload red LED, flashes in the FUSE mode
a fully loaded AS-Interface system with an
LED IR on red LED:
output current of 8 A.
ON: Plug-in jumper position 2-3
The voltage input range of the device can be

Extender, Repeaters
OFF: Plug-in jumper position 1-2

Power Supplies,
Plug-in jumper Position 1-2: Communication Mode selected on the front side. This makes it pos-
Position 2-3: IR addressing sible to operate the device on all single-
LED AS-i ok operating display; LED green phase power supply voltages commonly
Electrical specifications used worldwide.
Fusing T8A/250 V AC HBC (Not accessible) Certification of the device according to inter-
Capacity factor > 0.5 national and various national standards
Mains frequency 47 ... 63 Hz or DC allows for worldwide usage.

Safety at work
Efficiency typ. 92 % (at 230 V AC/8 A)
Rated operational voltage Ue nominal: 100 ... 120 V AC/220 ... 240 V AC (Selectable on front Safe operation using FUSE mode:
panel) To protect against overload and excess tem-
permissible: 85 ... 132 V AC/184 ... 264 V AC/230 ... 375 V DC perature, the device has a FUSE mode (elec-
Rated operational current Ie 6,0 A (Switch position 115 V) tronically simulated fuse), for permanent
2.8 A (Switch position 230 V)
shutoff of the output in the event of failure.
Overvoltage protection limited to max. 55 V
This turns off the device in the event of over-

Control cabinet
Output load, short circuit or excess temperature,

I/O Modules
Short-circuit protection/overload FUSE mode (2 ... 5 s contact current, then permanent tripping) thus protecting the AS-Interface cable and
Current limit > 8.4 A the attached components. A flashing LED
Current 8A indicates that the FUSE mode has been trig-
Voltage 30.55 V DC ± 3 % gered. Turning the device on again requires
Electrical isolation Overvoltage category III deliberately pressing a Reset button on the
Residual ripple ≤ 50 mVSS (500 kHz bandwidth, 50-Ω-measurement with front side of the unit. This prevents unwanted

Field application
ohmic load)
startup from occurring.

I/O Modules
Short-circuit current 12 ... 25 A (max. 5 s)
Standard conformity Operation without the AS-Interface string:
Electromagnetic compatibility Emitted interference in accordance with EN 50081-2 class B This AS-Interface power pack has an induc-
(EN 55011, EN 55022)
Interference immunity in accordance with EN 61000-6-2,
tive output. For operation without the AS-
EN 61000-4-2 to EN 61000-4-6, EN 61000-4-11 Interface string (for example lab measure-

Analogue modules
Ambient conditions ments) we recommend connecting a
Ambient temperature -10 ... 70 °C (263 ... 343 K) (Measured 25 mm below the 470 µF/35 V capacitor between AS-
device) Interface + and AS-Interface -. Standard
from 60° C 6W/°C power recovery? necessary commercial laboratory loads frequently tend
Storage temperature -25 ... 85 °C (248 ... 358 K) to oscillate and together with the data decou-
Degree of soiling 2 pling form a resonance that exceeds the per-
Mechanical specifications mitted modulation voltage.
Protection degree IP20 according to EN 60529

Other modules
Protection class 1 (IEC 536); Protective conductor connection necessary
Connection Connection terminals, max. conductor cross-section
flexible: 0.5 ... 4 mm2
fixed: 0.5 ... 6 mm2
stripped length 7 mm, connector sleeves are permissible
Material
Housing metal

Inductive sensors
Mass approx. 890 g

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 67
VAN-115/230AC-K7-DN

AS-Interface power supply VAN-115/230AC-K7-DN


Dimensions
Masters and
Gateways

120
120 112.5
Extender, Repeaters
Power Supplies,

134
Safety at work
Control cabinet

Electrical connection
I/O Modules

L
(V in) D AS-Interface + (VOUT1)
E
D C
Field application

O
I/O Modules

A
T U
Order code 115/230 V
P
screen (VOUT1)
manually A
L
VAN-115/230AC-K7-DN LED I
AS-Interface dual power supply N
G AS-Interface - (VOUT1)
Analogue modules

AS-Interface + (VOUT2)
D
Features E
D C
• PELV A O
T U
• 115 V AC / 230 V AC switchable screen (VOUT2)
A P
Other modules

L
• Two galvanically isolated outputs, LED I
each 30.55 V / 4 A N
N G AS-Interface - (VOUT2)
• AS-Interface filter integrated (GND in)
• LED operating display PE
• 89 % efficiency level
Inductive sensors

Indicating/operating means

Airflow direction
(Do not obstruct
Photoelectric

ventilation!)
sensors

LED (Vout1) LED (Vout2)

Screen Screen
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface + (brown) AS-Interface + (brown)

AS-Interface - (blue) AS-Interface - (blue)


Rotary encoders

PE (internal) PE (internal)
PE
L
N

115/230 V
Accessories

Mains voltage
selector switch

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
68 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-115/230AC-K7-DN
Technical data Function

Masters and
Indicators/operating means

Gateways
The primary switched-mode power supply
Mains power selection switch changeover switch for 115 V AC/230 V AC
unit was designed for field bus applications,
LED green Operating display
which transmit both energy and data via a
Electrical specifications two-wire cable (AS-Interface design). It pro-
Mains frequency 47 ... 63 Hz vides an output current of 2 x 4 A for two fully
Efficiency approx. 89 % developed AS-Interface systems.

Extender, Repeaters
Power Supplies,
Rated operational voltage Ue nominal: 115 V AC/230 V AC switchable; By means of two identical galvanically iso-
permissible: 88 ... 132 V AC/187 ... 264 V AC
lated outputs, the power supply unit provides
Rated operational current Ie 6 A at 115 V AC
2.8 A at 230 V AC
the energy, decouples data of the power
source and balances the two output cables
Output
(AS-Interface + and AS-Interface -) in rela-
Jumpering time 20 ms
tion to ground (screen connection). The pre-
Current 2x4 A
cise and transformer coupling permits the
Voltage 29.5 ... 31.6 V DC

Safety at work
use of unshielded load lines.
Switch-on delay ton 1 ms
The PELV output circuit is electronically pro-
Ambient conditions tected against overload and continuous short
Ambient temperature -10 ... 60 °C (263 ... 333 K) circuit. Its structure is equivalent to safety
Storage temperature -20 ... 100 °C (253 ... 373 K) isolating transformers per VDE 0551.
Mechanical specifications
Protection degree IP20 Fuse:

Control cabinet
Connection min. 0.5 mm2, max. 4 mm2 (rigid wire) The power supply unit is electronically pro-

I/O Modules
min. 0.5 mm2, max. 2.5 mm2 (strand) tected against external short circuits. In case
wire min. 9 mm, max. 15 mm separation
of a defect, the internal fuse disconnects the
Material
power supply unit from the supply.
Housing aluminium
Mass 1150 g
Note:
Do not remove any screws from the housing

Field application
without consulting us, since internal protec-

I/O Modules
tive earthing connections might disconnect.

Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 69
VAN-115/230AC-K8

AS-Interface power supply VAN-115/230AC-K8


Dimensions
Masters and
Gateways

140
Extender, Repeaters
Power Supplies,

110

90
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

Order code
VAN-115/230AC-K8
L
+
AS-Interface power supply (V in) AS-Interface +
D +
E
Analogue modules

D C
A O
T U GND screen
Features A P
L
• AS-Interface certificate LED I
N
-
• PELV N G AS-Interface -
(GND in) -
Other modules

• LED operating display


• Up to 2.8 A output load
PE
• 115 V AC to 230 V AC
• AS-Interface filter integrated
• Power factor correction
Inductive sensors

• Cable fed in from below

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Power LED green

Error LED red


Rotary encoders
Accessories

PE L1 N + - GND
AS-Interface

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
70 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-115/230AC-K8
Technical data Function

Masters and
Indicators/operating means

Gateways
The VAN-115/230AC-K8 power supply unit
LED ERROR overload display (beginning at 2.9 A output current); LED red
supplies a fully loaded AS-Interface system
LED ENERGY operating display; LED green
with an output current of 2.8 A.
Electrical specifications The sinusoidal current consumption of the
Fusing version TR5, 2 A delayed soldered in permanently internally power supply prevents harmonic waves; thus
Capacity factor at UE = 115 V: 0.99 this power supply unit has a particularly low

Extender, Repeaters
at UE = 230 V: 0.97

Power Supplies,
susceptibility to faults. The powerfactor cor-
Mains frequency 47 ... 63 Hz
rection ensures that the current is in phase
Rated operational voltage Ue nominal: 115 ... 230 V AC
permissible: 98 ... 265 V AC
with the voltage, so the capacity factor of
Rated operational current Ie 0.4 ... 1.2 A
cos ϕ > 0.97 prevents reactive power.
Ripple according to AS-Interface specification
Output
Current limit 3.5 A

Safety at work
Current 2.8 A
Voltage 29.5 ... 31.6 V DC
Standard conformity
Standards emitted interference to: EN 55022:1995 Class A, VDE 0878
Part 22:12.1995
interference resistance in acc. with: EN 50082-2:1995,
ENV 50140:02.95, ENV 50141:1994, ENV 50142:10.95,

Control cabinet
VDE 0839 Part 82-2:02.1996, VDE 0847 Part 3, VDE 0843

I/O Modules
Part 4/5/6
Ambient conditions
Ambient temperature 0 ... 70 °C (273 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree IP20 according to EN 60529

Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 71
VAN-24DC-K6

AS-Interface power supply VAN-24DC-K6


Dimensions
Masters and
Gateways

120
50 113

LED
Extender, Repeaters
Power Supplies,

130
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

Order code
VAN-24DC-K6
Ue+
AS-Interface power supply AS-Interface +
D
E
Analogue modules

D C
A O
T U screen
18 ... 32 V DC
Features voltage range A P
L
LED
• PELV I
N
• Input voltage 24 V DC G AS-Interface -
Ue-
Other modules

• Output current 3 A
• LED operating display
PE
• 88 % efficiency level
Inductive sensors

Indicating/operating means

Airflow direction
(Do not obstruct ventilation!)
Photoelectric
sensors

LED
Secondary

AS-Interface + (brown)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
side

AS-Interface - (blue)
Screen
Rotary encoders

PE (internal)

PE
Primary
side

Ue +
Ue -
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
72 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-24DC-K6
Technical data Function

Masters and
Indicators/operating means

Gateways
The VAN-24DC-K6 DC/DC transducer was
LED U AS-i AS-Interface voltage; LED green
designed for field bus applications, which
Electrical specifications transmit both energy and data via a two-wire
Rated operational voltage Ue 24 V DC cable (AS-Interface design). It powers a fully
18 ... 32 V DC (with full data content)
16 ... 40 V DC (short-time, under 18 V no start-up)
loaded AS-Interface system with a maximum
output current of 30.55 V and 3 A.

Extender, Repeaters
Rated operational current Ie 6 A at 24 V DC

Power Supplies,
In this case, the DC/DC transducer provides
Output
the energy, decouples data of the power
Short-circuit protection/overload max. 5 A
source and balances the two output cables
Current limit 3.15 ... 3.6 A
(AS-Interface + and AS-Interface -) in rela-
Current 3A
tion to ground (screen connection).
Voltage 29.5 ... 31.6 V DC
The precise and transformer coupling per-
Ambient conditions mits the use of unshielded load lines.
Ambient temperature -10 ... 70 °C (263 ... 343 K)

Safety at work
The PELV output circuit is electronically pro-
Storage temperature -20 ... 80 °C (253 ... 353 K) tected against overload and continuous short
Mechanical specifications circuit.
Protection degree IP20 according to EN 60529
Connection min. 0.5 mm2, max. 4 mm2 (rigid wire) Fuse:
min. 0.5 mm2, max. 2.5 mm2 (strand) The DC/DC transducer is electronically pro-
wire min. 9 mm, max. 15 mm separation
tected against continuous short circuit. In

Control cabinet
Mass approx. 550 g
case of a defect, the internal fuse discon-

I/O Modules
nects the DC/DC transducer from the power
supply.

Note:
Do not remove any screws from the housing
without consulting us, since internal protec-

Field application
tive earthing connections might disconnect!

I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 73
VAN-G4-PE

AS-Interface power supply VAN-G4-PE


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately


Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

Order code
VAN-G4-PE AS-Interface

AS-Interface power extender


Analogue modules

DATA
Features DECO UPLI NG

• Multiple AS-Interface networks can


be operated through a single power
stage
Other modules

Input voltage
• Up to 2.8 A output load
• G4 housing with screwed connection
• Protection degree IP67
• LEDs for display of AS-Interface
Inductive sensors

voltage

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface
output voltage
Rotary encoders

30 V input voltage
Accessories

Function ground

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
74 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface power supply VAN-G4-PE
Technical data Function

Masters and
Indicators/operating means

Gateways
The maximum cable length in an AS-Inter-
LED U AS-i AS-Interface voltage on the output is displayed in two stages:
face line is 100 m. There is often a great dis-
AS-Interface voltage > 28 V; LED green
AS-Interface voltage > 26 V; LED green tance to the modules in the field, when the
Electrical specifications power supply unit is located in the cabinet.
Insulation voltage Ui ≥ 500 V
When an AS-Interface power extender is
used, the distance between the power supply

Extender, Repeaters
Rated operational voltage Ue 30 V DC

Power Supplies,
Rated operational current Ie 2.8 A at 30 V
unit and the power extender is not included in
the calculation of the bus length. Instead of
Input
an AS-Interface power supply unit, a stand-
Lead monitoring self resetting fuse, 3 A
ard power supply unit with an output voltage
Output of 30 V in accordance with AS-Interface
Voltage 29.5 ... 31.6 V DC specifications can be used. The AS-Interface
Ambient conditions master and slaves are only usable on the

Safety at work
Ambient temperature 0 ... 70 °C (273 ... 343 K) side of the power extender opposite to the
Storage temperature -25 ... 85 °C (248 ... 358 K) power supply unit (AS-Interface output).
Mechanical specifications The AS-Interface power extender is located
Protection degree IP67 according to EN 60529 in an IP67 rated field housing. Small decen-
Connection standard AS-Interface EEMS base, i. e. cable piercing method tralized AS-Interface networks can easily be
screwed connection M12 x 1,5 and cage-clamp terminals arranged together with IP67 rated AS-Inter-
Mass 120 g face gateways.

Control cabinet
Depending on the lead resistance and the

I/O Modules
current, a voltage drop between the power
supply unit and the AS-Interface power
extender occurs. The AS-Interface power
extender indicates the AS-Interface voltage
on the output, in two stages (see technical
data) by means of two LEDs. It has to be

Field application
ensured that actuators are supplied with the

I/O Modules
permissible voltage tolerance of 24 V +10%/-
15%, as is the case with all AS-Interface cir-
cuits. A rule-of-thumb formula for the AS-
Interface cable length relative to the AS-
Interface voltage is:

Analogue modules
AS-Interface voltage > 28 V: approx. 80 m
cable length,
AS-Interface voltage > 26 V: approx. 60 m
cable length.

Note:
The AS-Interface power extender contains a
data decoupling for a maximum current of

Other modules
2.8 A at 30 V AS-Interface voltage.

Accessories
VAZ-G4-B
Blind plug PG7

Inductive sensors
Matching system components
U-G1FF
Base for connection to flat cable (EEMS;
AS-Interface and external auxiliary pow-
er)
Photoelectric

U-G1PP
sensors

Base for connection to round cable


(EEMS;
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface and external auxiliary volt-


age)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 75
VAR-G4F

AS-Interface repeater VAR-G4F


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

AS-Interface +
Order code FLT 1 AS-Interface
AS-Interface - circuit 2
VAR-G4F
PWR 1
AS-Interface repeater
Analogue modules

Features
• Line lengthening by 100 m (max. AS-Interface +
AS-Interface FLT 2
2 repeater in series) circuit 1 AS-Interface -

• Galvanic isolation between AS- PWR 2


Other modules

Interface circuits 1 and 2


• No parameterisation
• Need no specific address on the AS-
Interface bus
Inductive sensors

• Base included in delivery

Indicating/operating means
Photoelectric
sensors

FL 1

2
R

R
T1

T2
PW

PW
FL

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface circuit 2
Rotary encoders

AS-Interface circuit 1
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
76 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface repeater VAR-G4F
Technical data Function

Masters and
General specifications

Gateways
The VAR-G4F Repeater galvanically iso-
Cycle time 6 per telegram and transfer direction
lates two AS-Interface circuits from each
12 µs total per telegram
other and electrically preprocesses the AS-
Indicators/operating means
Interface signals, in that the cable length is
LED FLT error display; LED red
red: communication error
effectively extended by 100 m. Two repeaters
may be switched in series, thus resulting in a

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
maximum strand length of 300 m. The
Electrical specifications
Repeater requires no parameterisation and
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
no unique address on the AS-Interface; the
Rated operational current Ie 60 mA (per strand element), 120 mA (total)
total number of Slaves (31 or 62) per network
Standard conformity remains unchanged.
Electromagnetic compatibility according EN 50295 Both flat and round cables can be used for
Ambient conditions the connection of the AS-Interface transmis-

Safety at work
Ambient temperature -10 ... 55 °C (263 ... 328 K) sion line. If the flat AS-Interface cable is
Storage temperature -25 ... 75 °C (248 ... 348 K) used, then the base section supplied in the
Mechanical specifications delivery package must be used. The contact
Protection degree IP67 according to EN 60529 with both of the AS-Interface cables is estab-
Connection cable piercing method lished via the standardised EMS interface,
flat cable yellow i. e. using the insulation penetration tech-
Material nique. If the connection is made using round

Control cabinet
Housing plastic cable, then the U-G1PP base section must

I/O Modules
Mounting screw mounting be used.
Due to the galvanic isolation, each segment
Notes requires a power supply unit or a power
extender.
If connection of upper part with base U-G1PP: connect AS-Interface 2 + to terminal +, AS- Two LEDs indicate the correct polarity of the
Interface 2 - to terminal -, AS-Interface 1 + to terminal EXT+ and AS-Interface 1 - to terminal AS-Interface cables and two LEDs signal

Field application
EXT-. communication errors in the respective AS-

I/O Modules
Interface circuits.

Matching system components


U-G1PP

Analogue modules
Base for connection to round cable
(EEMS;
AS-Interface and external auxiliary volt-
age)

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 77
VAR-KE2

AS-Interface repeater VAR-KE2


Dimensions
Masters and
Gateways

22.5 7 85
Extender, Repeaters
Power Supplies,

99
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

AS-Interface +
Order code FLT 1 AS-Interface
AS-Interface - circuit 2
VAR-KE2 PWR 1
AS-Interface repeater
Analogue modules

Features
• Line lengthening by 100 m (max. AS-Interface +
AS-Interface FLT 2
2 repeater in series) circuit 1 AS-Interface -

• Galvanic isolation between AS- PWR 2


Other modules

Interface circuits 1 and 2


• No parameterisation
• Need no specific address on the AS-
Interface bus
Inductive sensors

• Housing with removable terminals

Indicating/operating means

n.c. n.c. AS-i2- AS-i2+


n.c. n.c. n.c. n.c.
Photoelectric
sensors

FAULT 1

FAULT 2
PWR 1

PWR 2

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

n.c. n.c. n.c. n.c.


AS-i1+ AS-i1- n.c. n.c.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
78 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface repeater VAR-KE2
Technical data Function

Masters and
Indicators/operating means

Gateways
The repeater VAR-KE2 galvanically sepa-
LED FAULT error display; LED red
rates two AS interface circuits, and condi-
red: communication error
tions the AS-Interface signals electrically,
LED PWR AS-Interface voltage; LED green
which extends the cable length by 100 m.
Electrical specifications
Two repeaters can be cascaded, resulting in
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
a maximum cable length of 300 m. The

Extender, Repeaters
Rated operational current Ie 60 mA (per strand element), 120 mA (total)

Power Supplies,
repeater does not require any parameterisa-
Standard conformity tion and no own address in the AS-Interface;
Electromagnetic compatibility according EN 50295 the overall number of slaves (31 or 62) per
Ambient conditions branch remains unchanged.
Ambient temperature 0 ... 55 °C (273 ... 328 K) The housing, only 22.5 mm in width, takes up
Storage temperature -25 ... 75 °C (248 ... 348 K) little place in the switch cabinet. The module
Mechanical specifications is mounted by snapping it on to the 35 mm

Safety at work
Protection degree IP20 according to EN 60529 mounting rail in keeping with European
Connection removable terminals, terminal connection ≤ 2.5 mm2 standard EN 50022. Pluggable screw termi-
Mounting DIN rail nals are used for connection. This method of
mounting permits easy removal during initial
operation or servicing.
On account of the galvanic separation, each
segment requires a power supply unit or a

Control cabinet
power extender.

I/O Modules
Two LEDs indicate the correct polarity of the
AS-Interface cables; two LEDs indicate any
communication errors in the respective AS-
Interface circuits.

Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 79
AS-Interface - Safety at Work
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
80 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Safety at Work

4 AS-Interface - Safety at work

Masters and
Gateways
The rubric of "AS-Interface Safety at Work" includes safe communications
based on AS-Interface. This system has been the industry standard for net-
working of sensors and actuators for years. The safety concept lowers in-
stallation costs for intrinsically safe components while adhering to current

Extender, Repeaters
Power Supplies,
safety regulations.
Typical danger spots are, for example, manually operated feed systems, in
which process availability and safety-oriented aspects compete. Short reac-
tion times are important, so that the switching-off of equipment occurs
quickly and minimal safety distances and margins are not exceeded.

Safety at work
The following functions are frequently required to limit the inherent dangers
to the minimum possible:
• EMERGENCY-STOP: For manual switch-off in the event of a fault
• Restart inhibit: For safety during and following a fault

Control cabinet
• Repair and maintenance: Safe access

I/O Modules
• Moveable protective systems: Monitor functional integrity
• Setup: Operating functionality and flexibility during re-tooling and process
sequences

Field application
• Safe operation: Minimising the risks during normal operation

I/O Modules
• Controlled restart: Achieved, for example, by the use of key-operated
switches after the cancellation of the restart inhibit
• Muting function: e. g. for feeding material, with by-pass of the safety func-
tion for a specified short period of time

Analogue modules
• Indicating via signal lamps: e.g. with activated muting function with in-
creased risk potential
• Access protection (e. g. Safety light barriers with a beam separation of
500 mm in accordance with EN 999)

Other modules
• Intervention protection (e. g. safety light grids with a beam separation of
25 mm)
• Finger protection (e. g. safety light curtain with a beam separation of
14 mm)
In these applications EN 954-1 "Safety of machines, safety-related parts of

Inductive sensors
controls (Categories 1 to 4)", EN 60204-1 "Safety of machines, electrical
equipment" and IEC 61508 "Functional Safety of electronic systems (Clas-
sified, for example, in terms of the probability of failure of the safety
system)" must be adhered to. The weakest link in the chain determines the
safety of the overall system.
Current solutions are often contrived, such that conventional sensors and
Photoelectric
sensors

actuators are installed using parallel wiring, in order to facilitate fault detec-
tion and fault rectification. AS-Interface Safety at Work sets new standards
here in terms of flexibility, diagnostic cabability and simplicity of installation.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

g s p otential
n
rs s a v i
... offe
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 81
AS-Interface - Safety at Work
4.1 The safety concept
Masters and
Gateways

No special cabling or control units are required to take advantage of the


benefits of the system. Intrinsically safe devices can be added to any exist-
ing AS-Interface line, simply by integrating one or more safety monitors into
the AS-Interface network. The monitor has the task of observing the re-
Extender, Repeaters

sponses from the "safe" slaves to the master. The higher level standard
Power Supplies,

master drives all the components in a network in the customary manner.


Check the product refer-
ence. This AS-Interface The AS-Interface transfer protocol is so immune to interference and fault-
Safety Logo indicates tolerant, that safety-related messages can be communicated. An additional
that the device is a safe monitoring of the "Safe" components is carried out by the safety monitor,
AS-Interface product. which constantly checks the communication between the standard master
Safety at work

The product-related in- and the "Safe" devices.


structions and restric-
tions must be observed. This operating principle is extraordinarily reliable and as such it can be used
up to category 4 in accordance with EN 954-1 "Safety of machines, safety-
related parts of controls" with TÜV approval. TÜV has certified the devices
and the BIA (Berufsgenossenschaftliche Institut für Arbeitsschutz) has also
Control cabinet

classified the communications as "safe".


I/O Modules

4.2 The advantages


Field application

In systems with safety-relevant processes, the yellow cable wiring harness-


I/O Modules

es required for conventional safety systems, are frequently in evidence.


There are cost savings here, for instance, in the wiring. Moreover, any kind
of modification of the system is extremely costly in terms of both time and
money.
Analogue modules

With the AS-Interface Safety at Work concept, an unshielded two-wire cable


is used. Extensions can be made at any point, simply and easily.
The AS-Interface flat cable guards against reverse polarity and the insula-
tion penetration connection technique facilitates fast installation. And it is
even possible to transfer safe and non-safe signals on one cable. Wherever
AS-Interface has already been installed safety-related components can
Other modules

simply be added to the system. Since the costs of installation often amount
to more than 40% of total plant costs, there is a tremendous savings poten-
tial here. But the potential for savings doesn't stop there. Take the control
cabinet, for example. No additional control units are required in the control
cabinet - once again leading to savings in equipment costs and space.
Inductive sensors

In the case of an Emergency-stop action the location from which this pre-
caution was initiated is immediately known. Then additional information on
the cause of the incident can be communicated and presented.
All these features establish the AS-Interface Safety at Work system as the
most cost-effective alternative for any field bus installation for standard ap-
plications.
Photoelectric
sensors

AS-Interface benefits at a glance:


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

• The many safety monitors facilitate grouping


• Master and control system remain unchanged
Rotary encoders

• Fail-safe PLCs are not required


• Safety at Work is compatible with existing AS-Interface systems
• Network is flexibly extensible at any time
• Safe and non-safe signals can share the same network
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
82 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Safety at Work
4.3 Safety monitor

Masters and
Gateways
The safety monitor has the task of monitoring the safe slaves to ensure their
fault-free function during normal operation and maintaining a safe condition
via positive-action relays in the event of a fault. To this end the safety mon-
itor "listens to" the AS-Interface communication. All the slaves are called up

Extender, Repeaters
by the master on every cycle. In addition to the input status of each of the

Power Supplies,
connected sensors/contacts the signal response of the safe slaves contains
a 4-bit safety code, which is continuously varied on each query according to
a stored, fixed algorithm. If this 4-bit code is not modified as expected a fault
condition is detected and the system is safely shut down. In this case the
code "0000" is transmitted and results in a switch-off in no more than
40 msec (max. cycle time including repetition and processing time). The

Safety at work
safety monitor requires no address, but it does allow an address to be as-
signed for communication with the master, so that all diagnostic information
is also available to the master.
The configuration of the initiation circuits is carried out by the ASIMON con-
figuration software, which enables the logic operations to be defined. Either

Control cabinet
I/O Modules
1 or 2 safe outputs are available to the safety monitor to facilitate the safe
shut down. The following functions can be configured in the safety monitor
in stop category 0 and stop category 1:
• EMERGENCY-STOP function
• Two-hand operation

Field application
I/O Modules
• Door locking
• Protection checks
• Restart inhibit

Analogue modules
The AS-Interface connection localises the position at which the EMERGEN-
CY-STOP is activated. In addition, further information on the type of fault
can be transferred, so that down time can be minimised.
The user can also choose betwee the Standard Safety Monitor and the "En-
hanced" Safety Monitor. The difference between these two monitors is indi-
cated in the following table:

Other modules
Technical features Standard Enhanced
Number of logic modules no AND, 6 x AND,
only 2 x OR 6 x OR,
1 R/S Flip-Flop

Inductive sensors
Number of configuration modules 32 48
Timer function No Yes
Contact debounce function No Yes
Deactivation of function modules No Yes
NOP (No operation) function as space holder1 No Yes
1 Due to timing reasons, at least 5 addresses must be given in the monitor.
Photoelectric

The NOP function allows virtual addresses to be used.


sensors

The state of the power-off circuit is displayed on the monitor using LEDs:
red LED on: switched off
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

yellow LED on: ready to restart after release


green LED on: running application
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 83
AS-Interface - Safety at Work
4.4 Safe slaves
Masters and
Gateways

In order to be able to cover the necessary functions in the system, safe

S
slaves are available which connect directly to the AS-Interface. These are,
for example emergency stop switches with an integrated AS-Interface inter-
connection, safe slaves with 2 safe inputs as well as safe slaves with 2 safe
Extender, Repeaters

inputs and 2 non-safe outputs, for example for the connection of contacts.
Power Supplies,

Safety category 3 is also achieved through separate assignment of the in-


The labeling of safe puts on the module. The two-channel input on the module must be used to
slaves is denoted by a provide safety category 4.
red "S".
Safe modules with non-safe outputs can be used for direct local signalling
on site. Using one data bit, inputs and outputs can simply be logically con-
Safety at work

nected in the module and, for example, a warning light or the LED in the
emergency stop switch can be controlled. However, due to the integrated
logic function in the module, only the output of the module must be fed to
the lamp. Previously it was necessary to route via the master, a software
routine in the PLC, a relay output in the control cabinet and the wiring from
Control cabinet

the control cabinet to the warning light.


I/O Modules

4.5 The ASIMON configuration software


The ASIMON softwar is used to configure and commission the safety mon-
itor via a PC with an RS 232 interface. The easy-to-understand control in-
Field application
I/O Modules

terface is used to assign safe inputs for shut-off circuits and monitor mod-
ules, to establish emergency-off or safety light grid functions, for example,
the assignment for the start modules as well as the selection of the output
modules (Stop category 0 or 1). The options are wide ranging, so that the
settings are suitable for almost all applications.
Analogue modules

System documentation for the safe components is supported, in that the


configuration can be stored and also printed out. The creation of a copy of
the configuration for other safety monitors is also possible. The following
steps are required to generate a configuration:
• Start the program and the "Start Assistant"
Other modules

• Select diagnostic function


• Establish configuration: Title, dependencies, slave addresses, assign-
ment of the slave to a module, complete AND/OR coupling module, deter-
mine stop category, define delay time.
• Assign an AS-Interface address for the safety monitor (Optional)
Inductive sensors

If a configuration already exists, this can be loaded and amended.


The assignment of modules from a symbol library to the two release circuits
takes place interactively by drag-and-drop.
When a configuration has been devised and checked it can be transferred
to the safety monitor and the code sequence of the safe slaves to be moni-
Photoelectric

tored can be taught in. The configuration protocol must then be checked
sensors

and enabled. The last step is to switch over the safety monitor from the con-
figuration mode to the protection mode.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

The functions New Configuration, Teach-in Code Sequence, Enable, Stop


Command and Change Password are password protected.
Rotary encoders

The ASIMON software provides extensive support for fault isolation and
fault rectification. In the ASIMON manual you will find several example ap-
plications to enable you to become quickly familiar with the system.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
84 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Safety at Work
4.6 Overivew of available AS-Interface Safety at Work products

Masters and
Gateways
Type code Function Page

VAS-1A-K12-U Standard Monitor, 1 shutdown circuit 86

Extender, Repeaters
Power Supplies,
VAS-1A-K12 Enhanced Monitor, 1 shutdown circuit 88

VAS-2A-K12-U Standard Monitor, 2 shutdown circuits 90

Safety at work
VAS-2A-K12 Enhanced Monitor, 2 shutdown circuits 92

Intrinsically safe field module, 2 safe inputs,


VAA-2E-G4-SN connection of SN sensors possible 94

Control cabinet
cable gland

I/O Modules
Intrinsically safe field module, 2 safe inputs/2 outputs
VAA-2E2A-G2-S/EA2 M12 connector 96
internal logical connection of inputs/outputs possible

Field application
Intrinsically safe field module, 2 safe inputs

I/O Modules
VAA-2E-G2-S 98
M12 connector

Intrinsically safe switch cabinet module, 2 safe inputs/2 outputs


VAA-2E2A-KE1-S/E2 Screw terminal connection 100
internal logical connection of inputs/outputs possible

Analogue modules
Intrinsically safe switch cabinet module, 2 safe inputs
VAA-2E-KE1-S 102
Screw terminal connection

Emergency stop switch,


VAA-2E-F85-V1 104
integrated AS-Interface connection

Other modules
ASIMON software package
VAZ-SW-SIMON 330

Inductive sensors
for configuration of AS-Interface Safety at Work

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 85
VAS-1A-K12-U

AS-Interface safety monitor VAS-1A-K12-U


Dimensions
Masters and
Gateways

7.2 (5x)
Extender, Repeaters
Power Supplies,

86.4

104.2
63.2

81.1
102
5
Safety at work

45 90.9
120
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

U® 1.13
Safety
Field application

1.14 switch output 1


I/O Modules

Order code .
.
1.23
Safety
. 1.24 switch output 2
VAS-1A-K12-U
Safety monitor, 1-channel 1.32 Message output
"Safety on"
Analogue modules

µP Input
1.Y1
"EDM"

Features 1.Y2 Input


"Start"
• One open circuit AS-Interface +
• Realising safety requirements in AS-Interface -
accordance with category 4 to
Other modules

EN 954-1 RJ45- – L+
+
socket – M Auxiliary energy
• Configuration and commissioning -
RS 232 –
with configuration software – PE
Inductive sensors

Indicating/operating means

1.13 1.23 1.Y1


Photoelectric

AS-i+ AS-i- 1.Y2


sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-i
Service
Rotary encoders

1
2 1 READY
2 ON
3 3 OFF/FAULT

CONFIG

L+ M 1.32
Accessories

1.14 1.24 PE

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
86 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety monitor VAS-1A-K12-U
Technical data Function

Masters and
General specifications

Gateways
When used in accordance with require-
Switch-on delay < 10 s
ments, the AS-Interface safety monitor
Response delay < 40 ms
makes it possible to operate sensor-control-
Indicators/operating means led personal protection equipment and other
LED green Off: contacts of the safety output (OSSD) open safety components up to and including
constantly lit: contacts of the safety output (OSSD) closed
Category 4 in accordance with EN 954-1. If

Extender, Repeaters
flashing: delay time running for Stop Category 1

Power Supplies,
LED yellow off: -
additional sensors of lower categories are
constantly lit: startup/restart lock active connected, the maximum category that can
flashing: external test required be achieved for the safety path in question is
LED red Off: contacts of the safety output (OSSD) closed determined by these sensors. For example,
constantly lit: contacts of the safety output (OSSD) open laser scanners can be classified to a maxi-
flashing: error
mum of Type 3 in accordance with
LED ENERGY from: no power supply
green, continuous illuminated: AS-Interface power supply
EN 61496-3. If laser scanners are included in

Safety at work
available the AS-Interface safety circuit, the maximum
LED AS-i from: normal operation safety category that can be achieved for the
red, continuous illuminated: communication error path in question is Category 3. Any safety
Electrical specifications light curtain of Type 4 connected to the same
Rated operational voltage Ue 24 V DC ± 15 % safety monitor remains unaffected by this.
ripple ≤ 15 % Category 4 is still possible for the safety light
26.5 ... 31.6 V from AS-Interface curtain.

Control cabinet
Rated operational current Ie ≤ 150 mA The safety monitor is also responsible for the

I/O Modules
≤ 45 mA from AS-Interface
compulsory EMERGENCY OFF function of
Overvoltage protection Overvoltage category III
for rated operational voltage 300 V DC acc. to VDE 0110
all non-manually controlled machines (Stop
Part 1 Category 0 or 1), dynamic monitoring of the
Interface restart function and the protection control
Interface type RS 232, serial
function.

Field application
Transfer rate 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits

I/O Modules
Input Documentation
Number/Type 2 opto-coupling inputs (high-active) "start" and "protection con-
trol (EDM)", input currents about 10 mA at 24 V DC The documentation includes manuals in
Output German and English. It is available on the In-
Safety output 2 potential free normally open contacts, ternet and in printed form as a CD-ROM on
max. contact load: request.

Analogue modules
1 A DC-13 at 24 V DC,
3 A AC-15 at 230 V AC
Output type Signal output: Software
PNP transistor output, 200 mA, short-circuit and reverse-polar-
ity-proof The configuration is made via the
Standard conformity configuration software VAZ-SW-SIMON,
Standards EN 50295 , EN 60947-5-1 , IEC 61508 (bis SIL 3), IEC 61496- which runs on any Windows 95/98/NT
1, EN 60204-1, EN 1088, EN 418, EN 954-1 (up to categorie Standard-PCs.

Other modules
4)
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K) Accessories
Storage temperature -30 ... 70 °C (243 ... 343 K)
VAZ-SW-SIMON
Mechanical specifications
Software for configuration of safety mon-
Protection degree IP20 (only for use in electrical operating rooms / switch cabinet
suitable with minimum protection type IP54) itors, connecting cable VAZ-SIMON-R2

Inductive sensors
Connection screw terminals
VAZ-SIMON-R2
Material
Housing Polyamide PA 66 , black
Interface cable for connecting the safety
Mass 350 g monitor to a PC
Mounting DIN rail mounting
VAZ-SIMON-RJ45
Interface cable for connecting two safety
monitors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 87
VAS-1A-K12

AS-Interface safety monitor VAS-1A-K12


Dimensions
Masters and
Gateways

7.2 (5x)
Extender, Repeaters
Power Supplies,

86.4

104.2
63.2

81.1
102
5
Safety at work

45 90.9
120
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

U® 1.13
Safety
Field application

1.14 switch output 1


I/O Modules

Order code .
.
1.23
Safety
. 1.24 switch output 2
VAS-1A-K12
Enhanced safety monitor, 1-channel 1.32 Message output
"Safety on"
Analogue modules

µP Input
1.Y1
"EDM"

Features 1.Y2 Input


"Start"
• One open circuit AS-Interface +
• Realising safety requirements in AS-Interface -
accordance with category 4 to
Other modules

EN 954-1 RJ45- – L+
+
socket – M Auxiliary energy
• Configuration and commissioning -
RS 232 –
with configuration software – PE

• extended logic functions


Inductive sensors

Indicating/operating means

1.13 1.23 1.Y1


Photoelectric

AS-i+ AS-i- 1.Y2


sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-i
Service
Rotary encoders

1
2 1 READY
2 ON
3 3 OFF/FAULT

CONFIG

L+ M 1.32
Accessories

1.14 1.24 PE

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
88 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety monitor VAS-1A-K12
Technical data Function

Masters and
General specifications

Gateways
When used in accordance with require-
Switch-on delay < 10 s
ments, the AS-Interface safety monitor
Response delay < 40 ms
makes it possible to operate sensor-control-
Indicators/operating means led personal protection equipment and other
LED green Off: contacts of the safety output (OSSD) open safety components up to and including
constantly lit: contacts of the safety output (OSSD) closed
Category 4 in accordance with EN 954-1. If

Extender, Repeaters
flashing: delay time running for Stop Category 1

Power Supplies,
LED yellow off: -
additional sensors of lower categories are
constantly lit: startup/restart lock active connected, the maximum category that can
flashing: external test required be achieved for the safety path in question is
LED red Off: contacts of the safety output (OSSD) closed determined by these sensors. For example,
constantly lit: contacts of the safety output (OSSD) open laser scanners can be classified to a maxi-
flashing: error
mum of Type 3 in accordance with
LED ENERGY from: no power supply
green, continuous illuminated: AS-Interface power supply
EN 61496-3. If laser scanners are included in

Safety at work
available the AS-Interface safety circuit, the maximum
LED AS-i from: normal operation safety category that can be achieved for the
red, continuous illuminated: communication error path in question is Category 3. Any safety
Electrical specifications light curtain of Type 4 connected to the same
Rated operational voltage Ue 24 V DC ± 15 % safety monitor remains unaffected by this.
ripple ≤ 15 % Category 4 is still possible for the safety light
26.5 ... 31.6 V from AS-Interface curtain.

Control cabinet
Rated operational current Ie ≤ 150 mA The safety monitor is also responsible for the

I/O Modules
≤ 45 mA from AS-Interface
compulsory EMERGENCY OFF function of
Overvoltage protection Overvoltage category III
for rated operational voltage 300 V DC acc. to VDE 0110
all non-manually controlled machines (Stop
Part 1 Category 0 or 1), dynamic monitoring of the
Interface restart function and the protection control
Interface type RS 232, serial
function.

Field application
Transfer rate 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits

I/O Modules
Input Documentation
Number/Type 2 opto-coupling inputs (high-active) "start" and "protection con-
trol (EDM)", input currents about 10 mA at 24 V DC The documentation includes manuals in
Output German and English. It is available on the In-
Safety output 2 potential free normally open contacts, ternet and in printed form as a CD-ROM on
max. contact load: request.

Analogue modules
1 A DC-13 at 24 V DC,
3 A AC-15 at 230 V AC
Output type Signal output: Software
PNP transistor output, 200 mA, short-circuit and reverse-polar-
ity-proof The configuration is made via the
Standard conformity configuration software VAZ-SW-SIMON,
Standards EN 50295 , EN 60947-5-1 , IEC 61508 (bis SIL 3), IEC 61496- which runs on any Windows 95/98/NT
1, EN 60204-1, EN 1088, EN 418, EN 954-1 (up to categorie Standard-PCs.

Other modules
4)
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K) Accessories
Storage temperature -30 ... 70 °C (243 ... 343 K)
VAZ-SW-SIMON
Mechanical specifications
Software for configuration of safety mon-
Protection degree IP20 (only for use in electrical operating rooms / switch cabinet
suitable with minimum protection type IP54) itors, connecting cable VAZ-SIMON-R2

Inductive sensors
Connection screw terminals
VAZ-SIMON-R2
Material
Housing Polyamide PA 66 , black
Interface cable for connecting the safety
Mass 350 g monitor to a PC
Mounting DIN rail mounting
VAZ-SIMON-RJ45
Interface cable for connecting two safety
monitors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 89
VAS-2A-K12-U

AS-Interface safety monitor VAS-2A-K12-U


Dimensions
Masters and
Gateways

7.2 (5x)
Extender, Repeaters
Power Supplies,

86.4

104.2
63.2

81.1
102
5
Safety at work

45 90.9
120
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

Device 2-channel
(x=1 resp. x=2)
U® x.13
Safety
Field application

x.14 switch output 1


I/O Modules

Order code .
.
x.23
Safety
. x.24 switch output 2
VAS-2A-K12-U
Safety monitor, 2-channel x.32 Message output
"Safety on"
Analogue modules

µP Input
x.Y1
"EDM"

Features x.Y2 Input


"Start"
• Two dependent or independent open AS-Interface +
circuits
AS-Interface -
• Realising safety requirements in
Other modules

accordance with category 4 to RJ45- – L+


+
EN 954-1 socket – M Auxiliary energy
-
RS 232 –
• Configuration and commissioning – PE
with configuration software
Inductive sensors

Indicating/operating means

1.13 1.23 1.Y1 2.23 2.23 2.Y1


Photoelectric

AS-i+ AS-i- 1.Y2 2.Y2


sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-i
Service
Rotary encoders

1 1
2 1 READY 2
2 ON
3 3 OFF/FAULT

CONFIG

L+ M 1.32 2.32
Accessories

1.14 1.24 PE 2.14 2.24

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
90 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety monitor VAS-2A-K12-U
Technical data Function

Masters and
General specifications

Gateways
When used in accordance with require-
Switch-on delay < 10 s
ments, the AS-Interface safety monitor
Response delay < 40 ms
makes it possible to operate sensor-control-
Indicators/operating means led personal protection equipment and other
LED green Off: contacts of the safety output (OSSD) open safety components up to and including
constantly lit: contacts of the safety output (OSSD) closed
Category 4 in accordance with EN 954-1. If

Extender, Repeaters
flashing: delay time running for Stop Category 1

Power Supplies,
LED yellow off: -
additional sensors of lower categories are
constantly lit: startup/restart lock active connected, the maximum category that can
flashing: external test required be achieved for the safety path in question is
LED red Off: contacts of the safety output (OSSD) closed determined by these sensors. For example,
constantly lit: contacts of the safety output (OSSD) open laser scanners can be classified to a maxi-
flashing: error
mum of Type 3 in accordance with
LED ENERGY from: no power supply
green, continuous illuminated: AS-Interface power supply
EN 61496-3. If laser scanners are included in

Safety at work
available the AS-Interface safety circuit, the maximum
LED AS-i from: normal operation safety category that can be achieved for the
red, continuous illuminated: communication error path in question is Category 3. Any safety
Electrical specifications light curtain of Type 4 connected to the same
Rated operational voltage Ue 24 V DC ± 15 % safety monitor remains unaffected by this.
ripple ≤ 15 % Category 4 is still possible for the safety light
26.5 ... 31.6 V from AS-Interface curtain.

Control cabinet
Rated operational current Ie ≤ 200 mA The safety monitor is also responsible for the

I/O Modules
≤ 45 mA from AS-Interface
compulsory EMERGENCY OFF function of
Overvoltage protection Overvoltage category III
for rated operational voltage 300 V DC acc. to VDE 0110
all non-manually controlled machines (Stop
Part 1 Category 0 or 1), dynamic monitoring of the
Interface restart function and the protection control
Interface type RS 232, serial
function.

Field application
Transfer rate 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits

I/O Modules
Input Documentation
Number/Type 2 opto-coupling inputs (high-active) "start" and "protection con-
trol (EDM)", input currents about 10 mA at 24 V DC The documentation includes manuals in
Output German and English. It is available on the In-
Safety output 2 x 2 potential free normally open contact, ternet and in printed form as a CD-ROM on
max. contact rating: request.

Analogue modules
1 A DC-13 by 24 V DC,
3 A AC-15 by 230 V AC
Output type Signal output: Software
PNP transistor output, 200 mA, short-circuit and reverse-polar-
ity-proof The configuration is made via the
Standard conformity configuration software VAZ-SW-SIMON,
Standards EN 50295 , EN 60947-5-1 , IEC 61508 (bis SIL 3), IEC 61496- which runs on any Windows 95/98/NT
1, EN 60204-1, EN 1088, EN 418, EN 954-1 (up to categorie Standard-PCs.

Other modules
4)
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K) Accessories
Storage temperature -30 ... 70 °C (243 ... 343 K)
VAZ-SW-SIMON
Mechanical specifications
Software for configuration of safety mon-
Protection degree IP20 (only for use in electrical operating rooms / switch cabinet
suitable with minimum protection type IP54) itors, connecting cable VAZ-SIMON-R2

Inductive sensors
Connection screw terminals
VAZ-SIMON-R2
Material
Housing Polyamide PA 66 , black
Interface cable for connecting the safety
Mass 450 g monitor to a PC
Mounting DIN rail mounting
VAZ-SIMON-RJ45
Interface cable for connecting two safety
monitors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 91
VAS-2A-K12

AS-Interface safety monitor VAS-2A-K12


Dimensions
Masters and
Gateways

7.2 (5x)
Extender, Repeaters
Power Supplies,

86.4

104.2
63.2

81.1
102
5
Safety at work

45 90.9
120
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

Device 2-channel
(x=1 resp. x=2)
U® x.13
Safety
Field application

x.14 switch output 1


I/O Modules

Order code .
.
x.23
Safety
. x.24 switch output 2
VAS-2A-K12
Enhanced safety monitor, 2-channel x.32 Message output
"Safety on"
Analogue modules

µP Input
x.Y1
"EDM"

Features x.Y2 Input


"Start"
• Two dependent or independent open AS-Interface +
circuits
AS-Interface -
• Realising safety requirements in
Other modules

accordance with category 4 to RJ45- – L+


+
EN 954-1 socket – M Auxiliary energy
-
RS 232 –
• Configuration and commissioning – PE
with configuration software
• extended logic functions
Inductive sensors

Indicating/operating means

1.13 1.23 1.Y1 2.23 2.23 2.Y1


Photoelectric

AS-i+ AS-i- 1.Y2 2.Y2


sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-i
Service
Rotary encoders

1 1
2 1 READY 2
2 ON
3 3 OFF/FAULT

CONFIG

L+ M 1.32 2.32
Accessories

1.14 1.24 PE 2.14 2.24

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
92 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety monitor VAS-2A-K12
Technical data Function

Masters and
General specifications

Gateways
When used in accordance with require-
Switch-on delay < 10 s
ments, the AS-Interface safety monitor
Response delay < 40 ms
makes it possible to operate sensor-control-
Indicators/operating means led personal protection equipment and other
LED green Off: contacts of the safety output (OSSD) open safety components up to and including
constantly lit: contacts of the safety output (OSSD) closed
Category 4 in accordance with EN 954-1. If

Extender, Repeaters
flashing: delay time running for Stop Category 1

Power Supplies,
LED yellow off: -
additional sensors of lower categories are
constantly lit: startup/restart lock active connected, the maximum category that can
flashing: external test required be achieved for the safety path in question is
LED red Off: contacts of the safety output (OSSD) closed determined by these sensors. For example,
constantly lit: contacts of the safety output (OSSD) open laser scanners can be classified to a maxi-
flashing: error
mum of Type 3 in accordance with
LED ENERGY from: no power supply
green, continuous illuminated: AS-Interface power supply
EN 61496-3. If laser scanners are included in

Safety at work
available the AS-Interface safety circuit, the maximum
LED AS-i from: normal operation safety category that can be achieved for the
red, continuous illuminated: communication error path in question is Category 3. Any safety
Electrical specifications light curtain of Type 4 connected to the same
Rated operational voltage Ue 24 V DC ± 15 % safety monitor remains unaffected by this.
ripple ≤ 15 % Category 4 is still possible for the safety light
26.5 ... 31.6 V from AS-Interface curtain.

Control cabinet
Rated operational current Ie ≤ 200 mA The safety monitor is also responsible for the

I/O Modules
≤ 45 mA from AS-Interface
compulsory EMERGENCY OFF function of
Overvoltage protection Overvoltage category III
for rated operational voltage 300 V DC acc. to VDE 0110
all non-manually controlled machines (Stop
Part 1 Category 0 or 1), dynamic monitoring of the
Interface restart function and the protection control
Interface type RS 232, serial
function.

Field application
Transfer rate 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits

I/O Modules
Input Documentation
Number/Type 2 opto-coupling inputs (high-active) "start" and "protection con-
trol (EDM)", input currents about 10 mA at 24 V DC The documentation includes manuals in
Output German and English. It is available on the In-
Safety output 2 x 2 potential free normally open contact, ternet and in printed form as a CD-ROM on
max. contact rating: request.

Analogue modules
1 A DC-13 by 24 V DC,
3 A AC-15 by 230 V AC
Output type Signal output: Software
PNP transistor output, 200 mA, short-circuit and reverse-polar-
ity-proof The configuration is made via the
Standard conformity configuration software VAZ-SW-SIMON,
Standards EN 50295 , EN 60947-5-1 , IEC 61508 (bis SIL 3), IEC 61496- which runs on any Windows 95/98/NT
1, EN 60204-1, EN 1088, EN 418, EN 954-1 (up to categorie Standard-PCs.

Other modules
4)
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K) Accessories
Storage temperature -30 ... 70 °C (243 ... 343 K)
VAZ-SW-SIMON
Mechanical specifications
Software for configuration of safety mon-
Protection degree IP20 (only for use in electrical operating rooms / switch cabinet
suitable with minimum protection type IP54) itors, connecting cable VAZ-SIMON-R2

Inductive sensors
Connection screw terminals
VAZ-SIMON-R2
Material
Housing Polyamide PA 66 , black
Interface cable for connecting the safety
Mass 450 g monitor to a PC
Mounting DIN rail mounting
VAZ-SIMON-RJ45
Interface cable for connecting two safety
monitors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 93
VAA-2E-G4-SN

AS-Interface safety module VAA-2E-G4-SN


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately


Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK
Field application

1.1 1.2 1.3 2.1 2.2 2.3 1.1 1.2 1.3 2.1 2.2 2.3
I/O Modules

S+1 RES S-1 S-2 RES S+2 S+1 RES S-1 S-2 RES S+2

Order code
VAA-2E-G4-SN
3.1 3.2 3.3 4.1 4.2 4.3 3.1 3.2 3.3 4.1 4.2 4.3
L+1 EM1 L-1 L-2 EM2 L+2
G4 PG module IP67 L+1 EM1 L-1 L-2 EM2 L+2

safety module with 2 inputs


Analogue modules

Features
• Two inputs for SN sensors or two
mechanical contacts such as
EMERGENCY-STOP switch 1.1 1.2 1.3 2.1 2.2 2.3 1.1 1.2 1.3 2.1 2.2 2.3
Other modules

S+1 RES S-1 S-2 RES S+2 S+1 RES S-1 S-2 RES S+2

• Protection degree IP67


• Flat or round cable connection (via
standardised EMS base, not included 3.1 3.2 3.3 4.1 4.2 4.3 3.1 3.2 3.3 4.1 4.2 4.3
L+1 EM1 L-1 L-2 EM2 L+2 L+1 EM1 L-1 L-2 EM2 L+2

in the delivery package)


• Cross-circuit detection for
Inductive sensors

mechanical switches

Indicating/operating means
Photoelectric
sensors

I1 I2
FAULT
PWR

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

I1 I2
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
94 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety module VAA-2E-G4-SN
Technical data Function

Masters and
General specifications

Gateways
When used in accordance with conditions in
Slave type Standard slave
combination with an AS-Interface safety
Indicators/operating means monitor, this AS-Interface safety slave makes
LED FAULT error display; LED red it possible to operate sensor-driven personal
red: communication error or address is 0
protection equipment. The slave is equipped
LED PWR AS-Interface voltage; LED green
with two safety-related inputs to which a

Extender, Repeaters
LED IN switching state (input); 2 LED yellow

Power Supplies,
mechanical switch or a secure inductive sen-
Electrical specifications sor of Pepperl+Fuchs in accordance with the
Protection class III SN specification can be connected.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface When single channel force-directed mechan-
Rated operational current Ie ≤ 70 mA ical switches are connected, up to Category
Fault current If ≤ 90 mA 3 in accordance with EN 954-1 can be
Input achieved, given the appropriate wiring and

Safety at work
Number/Type 2 Inputs for SN sensors (category S, EN 60947-5-3; category selection of switch. Often the wiring of a sin-
3+4, EN 954-1) or for mechanical contacts (category 4, EN gle-channel switch is implemented in such a
954-1) Inputs for mech. switch, monitored for cross-circuit,
cable length < 30 m
manner that a short circuit can be excluded
Supply from AS-Interface
in one channel (for example by protecting
Current loading capacity input current limited ≤ 15 mA,
that channel or with a sufficiently insulated
overload and short-circuit resistant wire). Without this error exclusion, up to Cat-
Switching point SN specification egory 2 can be achieved.

Control cabinet
mech. switch current 10 mA pulsed When a two-channel force-directed mechani-

I/O Modules
Programming instructions cal switch is connected, up to Category 4 in
Profile S-0.B accordance with EN 954-1 can be achieved,
IO code 0 given the appropriate wiring and selection of
ID code B switch. Both inputs of the slave are assigned.
ID1 code F The two channels of the mechanical switch
ID2 code E are monitored for a cross circuit.

Field application
When SN sensors are connected, an input

I/O Modules
Data bits (function via AS-Interface) input output
D0 dyn. safety code S1 - achieves Category 3 in accordance with
D1 dyn. safety code S1 - EN 954-1 given the appropriate wiring, in
D2 dyn. safety code S2 - case of functional dependent proximity
D3 dyn. safety code S2 - switches up to Category 4 can be achieved.
Parameter bits (programmable via AS-i) function Cables of SN sensors are monitored for

Analogue modules
P0 not used short circuit and lead breakage. The SN sen-
P1 not used sors may not be connected via a common
P2 not used cable, unless a cross circuit between both
P3 not used sensor inputs can be excluded by protected
Standard conformity wiring.
Insulation coordination EN 50178
Electromagnetic compatibility EN 61000-6-2, EN 61000-4-x, EN 61000-4-5 1kV asymmetric, Accessories
criterion B, EN 50081, EN 55011

Other modules
Protection degree EN 60529 VBP-HH1
Fieldbus standard EN 50295, IEC 62026-2 Hand-held programming device
Functional safety EN 954-1:1996 (Up to category 4), BIA final draft "Proposal for
a principle for the verification and certification of field busses VAZ-G4-B
for the transmission of safety related signals" 28.05.2000 Blind plug PG7
Standards IEC 60204-1

Inductive sensors
Ambient conditions
Matching system components
Ambient temperature -25 ... 55 °C (248 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) U-G1FA
Mechanical specifications Base with addressing jack for connection
Protection degree IP67 to flat cable (EMS; AS-Interface only)
This protection class is achieved by using the AS-Interface flat
cable VAZ-FK-S-YE U-G1F
Connection cable piercing method or terminal compartment Base for connection to flat cable (EMS;
Photoelectric

flat cable yellow or standard round cable


AS-Interface only)
sensors

inputs: screwed connection M12 x 1,5 and cage-clamp termi-


nals
Mass 180 g
U-G1P
Base for connection to round cable
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Mounting DIN rail or screw mounting


(EMS;
Notes AS-Interface only)
Rotary encoders

The cables and the laying of the cables have to meet the standards which apply to the partic-
ular application, e.g. IEC 60204. The instructions for the intended use, the selection and the
correct connection of the sensors or the selection and the attainment of the corresponding
safety category are given in the manual.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 95
VAA-2E2A-G2-S/EA2

AS-Interface safety module VAA-2E2A-G2-S/EA2


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

M12 x 1 quick disconnect


U
®
S1
1
LISTED 57M3
AS-Interface - IN1+
IND. CONT. EQ.
CLASS 2 CIRCUIT ONLY 2 Switch
IN1-
Field application

3
AS-Interface + IN2+
I/O Modules

4
IN2-
Order code 5
RES
VAA-2E2A-G2-S/EA2 1
S2
IN2+
G2 safety module 2 Switch
IN2-
3
2 safety-related inputs and ADDR (nc)
4
Analogue modules

(nc)
2 conventional electronic outputs 5
RES
OUT1
1
(nc)
Features 4
OUT1
2
• Addressing jack OUT2 Load
3
AUX-
5
• Flat cable connection with cable PWR FG
piercing technique, variable flat cable OUT2
Other modules

FAULT 1
(nc)
guide 4
OUT2
2
• Communication monitoring (nc) Load
3
AUX-
AUX 5
• Power supply of outputs from the FG
AUX+
external auxiliary voltage
AUX- Functional ground (FG)
Inductive sensors

• 2 inputs for mechanical contacts such Ground connection


as EMERGENCY-STOP switch via mounting base

• Power supply of inputs from the


module Indicating/operating means
• Function display for bus, ext. auxiliary
voltage, inputs and outputs
4
Photoelectric

1 3 4
• Output overload monitoring
sensors

5 5
• Switchable internal logic operation of 3 2 2 1
the inputs and outputs via parameter OUT1 OUT2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

bit 4 1 3 4
5 5
Rotary encoders

3 2 2 1
S1 S2

PWR
S
FAULT

C UL US

LISTED57M3
AUX ADDR
IND. CONT. EQ.
CLASS 2 CIRCUIT ONLY
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
96 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety module VAA-2E2A-G2-S/EA2
Technical data Function

Masters and
General specifications

Gateways
The VAA-2E2A-G2-S/EA2 is an AS-Inter-
Slave type Standard slave
face safety module with 2 safety-related
Indicators/operating means inputs and 2 conventional outputs. A dual
LED FAULT error display; LED red channel mechanical switch or in each case a
red: communication error or address is 0
red flashing: Output supply overload
single channel mechanical switch can be
connected to the two safety-related inputs.

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green
The outputs are conventional electronic out-
LED IN switching state (input); 2 LED yellow
puts, which may be loaded in total with 2 A
LED OUT switching state (output); 2 LED yellow
(max. 1 A per output).
The IP67 flat module features an integrated
Electrical specifications
addressing jack and is ideal for applications
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
in the field.
Protection class III
The connection to the switches/actuators is
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface

Safety at work
set up by means of M12 x 1-screw connec-
Rated operational current Ie ≤ 70 mA
tions. The current switching state of each
Input channel is indicated by an LED, located on
Number/Type 2 safety-related inputs for mechanical contacts, cross-circuit the module's top side. Similarly, an LED is
monitored: 2 single-channel contacts: up to category 2 to EN
954-1 or 1 2-channel contact: up to category 4 to EN 954-1
provided to monitor the AS-Interface commu-
Cable length must exceed 30 m per input. nication and to indicate that the module has
Supply from AS-Interface the address 0. If a communication error

Control cabinet
occurs, the outputs are de-energized (only

I/O Modules
Voltage 20 ... 30 V DC pulsed
Current loading capacity input current limited ≤ 15 mA, P0=1).
overload and short-circuit resistant When single channel force-directed mechan-
Output ical switches are connected, up to
Number/Type 2 conventional electronic outputs, PNP Category 2 in accordance with EN 954-1 can
Supply from external auxiliary voltage UAUX be achieved, given the appropriate wiring
Current 1 A per output and selection of switch.

Field application
≥ (UAUX - 0,5 V) When a two-channel force-directed mechani-

I/O Modules
Voltage
Programming instructions cal switch is connected, up to Category 4 in
Profile S-7.B accordance with EN 954-1 can be achieved,
IO code 7 given the appropriate wiring and selection of
ID code B switch.
ID1 code F Both inputs of the module are assigned. The

Analogue modules
ID2 code 0 two channels of the mechanical switch are
Data bits (function via AS-Interface) input output monitored for a cross circuit. LEDs are also
D0 dyn. safety code S1 OUT 1 provided to indicate AS-Interface voltage and
D1 dyn. safety code S1 OUT 2 external power supply.
D2 dyn. safety code S2 - As per approval in accordance with
D3 dyn. safety code S2 - IEC 61508 up to SIL 3 can be achieved.
Parameter bits (programmable via AS-i) function The U-G3FF mounting base is normally used
for the connection of the AS-Interface flat

Other modules
P0 Logic operation:
P0 = 1 (Basic setting): The outputs are controlled via AS-Inter- cable and the external sensor power supply.
face. The specially designed base enables the
P0 = 0: The outputs are controlled via AS-Interface or the user to connect flat cables from both sides.
inputs. The corresponding output is activated on opening the
contacts of an input.
P1 ... P3 not used Note:
The mounting base for the module is sold
Standard conformity

Inductive sensors
separately.
Insulation coordination EN 50178
Electromagnetic compatibility EN 50295, EN 61326, EN 61496-1, EN 61000-6-2, EN 61000-
4-5 1kV asymmetric, criterion B Accessories
Protection degree EN 60529
Fieldbus standard EN 50295, IEC 62026-2 VBP-HH1
Functional safety EN 954-1:1996 (up to category 4), BIA Final Draft "Proposal Hand-held programming device
for a principle to the verification and certification of field busses
for transmission of safety related signals" 28.05.2000, VAZ-PK-1,5M-V1-G
Photoelectric

IEC 61508 up to SIL3 Connection cable module/hand-held pro-


sensors

Standards IEC 60204-1


gramming device
Ambient conditions
Ambient temperature -25 ... 55 °C (248 ... 328 K) VAZ-FK-ED-G2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Storage temperature -25 ... 85 °C (248 ... 358 K) AS-Interface end seal for G2 modules
Mechanical specifications
V1-CLIP
Rotary encoders

Protection degree IP67


Connection cable piercing method
Interlock protection for M12 connector
flat cable yellow/flat cable black
inputs/outputs: M12 round connector
Matching system components
Mass 100 g
Mounting Mounting base U-G3FF
Mounting plate for connection to flat ca-
Notes
ble (AS-Interface and external auxiliary
Accessories

The cables and the laying of the cables have to meet the standards which apply to the particular applica- power)
tion, e.g. IEC 60204. The instructions for the intended use, the selection and the correct connection of the
sensors/actuators or the selection and the attainment of the corresponding safety category are given in the
manual.
The outputs may not be used for safety-related functions!

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 97
VAA-2E-G2-S

AS-Interface safety module VAA-2E-G2-S


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

M12 x 1 quick disconnect


U S1
1
®

LISTED 57M3
AS-Interface - IN1+
IND. CONT. EQ.
CLASS 2 CIRCUIT ONLY 2 Switch
IN1-
Field application

AS-Interface + 3
IN2+
I/O Modules

4
IN2-
Order code 5
RES
VAA-2E-G2-S 1
S2
IN2+
G2 safety module 2 Switch
IN2-
3
2 safety-related inputs ADDR (nc)
4
Analogue modules

(nc)
5
RES

Features
• Addressing jack
• Flat cable connection with cable PWR
piercing technique, variable flat cable
Other modules

FAULT
guide
• Communication monitoring
• 2 inputs for mechanical contacts such
as EMERGENCY-STOP switch
Inductive sensors

• Power supply of inputs from the


module
• Function display for bus and inputs
Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

4 1 3 4
5 5
Rotary encoders

3 2 2 1
S1 S2

PWR
S
FAULT

C UL US

LISTED57M3 ADDR
IND. CONT. EQ.
CLASS 2 CIRCUIT ONLY
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
98 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety module VAA-2E-G2-S
Technical data Function

Masters and
General specifications

Gateways
The VAA-2E-G2-S is an AS-Interface safety
Slave type Standard slave
module with 2 safety-related inputs. A dual
Indicators/operating means channel mechanical switch or in each case a
LED FAULT error display; LED red single channel mechanical switch can be
red: communication error or address is 0
connected to the two inputs.
LED PWR AS-Interface voltage; LED green
The IP67 flat module features an integrated

Extender, Repeaters
LED IN switching state (input); 2 LED yellow

Power Supplies,
addressing jack and is ideal for applications
Electrical specifications in the field.
Protection class III The connection to the switches is set up by
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface means of M12 x 1-screw connections. The
Rated operational current Ie ≤ 70 mA current switching state of each channel is
Input indicated by an LED, located on the module's
Number/Type 2 safety-related inputs for mechanical contacts, cross-circuit top side. Similarly, an LED is provided to
monitored:

Safety at work
monitor the AS-Interface communication and
2 single-channel contacts: up to category 2 to EN 954-1 or
1 2-channel contact: up to category 4 to EN 954-1
to indicate that the module has the
Cable length must exceed 30 m per input. address 0.
Supply from AS-Interface When single channel force-directed mechan-
Voltage 20 ... 30 V DC pulsed ical switches are connected, up to
Current loading capacity input current limited ≤ 15 mA, Category 2 in accordance with EN 954-1 can
overload and short-circuit resistant be achieved, given the appropriate wiring

Control cabinet
and selection of switch.

I/O Modules
Programming instructions
Profile S-0.B When a two-channel force-directed mechani-
IO code 0 cal switch is connected, up to Category 4 in
ID code B accordance with EN 954-1 can be achieved,
ID1 code F given the appropriate wiring and selection of
ID2 code 0 switch.
Data bits (function via AS-Interface) input output Both inputs of the module are assigned. The

Field application
two channels of the mechanical switch are

I/O Modules
D0 dyn. safety code S1 -
D1 dyn. safety code S1 - monitored for a cross circuit. LEDs are also
D2 dyn. safety code S2 - provided to indicate AS-Interface voltage and
D3 dyn. safety code S2 - external power supply.
Parameter bits (programmable via AS-i) function As per approval in accordance with
P0 not used IEC 61508 up to SIL 3 can be achieved.

Analogue modules
P1 not used The U-G3FF mounting base is normally used
P2 not used for the connection of the AS-Interface flat
P3 not used cable and the external sensor power supply.
Standard conformity The specially designed base enables the
Insulation coordination EN 50178 user to connect flat cables from both sides.
Electromagnetic compatibility EN 50295, EN 61326, EN 61496-1, EN 61000-6-2, EN 61000-
4-5 1kV asymmetric, criterion B Note:
Protection degree EN 60529 The mounting base for the module is sold

Other modules
Fieldbus standard EN 50295, IEC 62026-2 separately.
Functional safety EN 954-1:1996 (up to category 4), BIA Final Draft "Proposal
for a principle to the verification and certification of field busses
for transmission of safety related signals" 28.05.2000, Accessories
IEC 61508 up to SIL3
Standards IEC 60204-1
VBP-HH1
Hand-held programming device
Ambient conditions

Inductive sensors
Ambient temperature -25 ... 55 °C (248 ... 328 K) VAZ-PK-1,5M-V1-G
Storage temperature -25 ... 85 °C (248 ... 358 K) Connection cable module/hand-held pro-
Mechanical specifications gramming device
Protection degree IP67
Connection cable piercing method VAZ-FK-ED-G2
flat cable yellow/flat cable black AS-Interface end seal for G2 modules
inputs/outputs: M12 round connector
Photoelectric

Mass 100 g V1-CLIP


sensors

Mounting Mounting base Interlock protection for M12 connector

Notes
Matching system components
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

The cables and the laying of the cables have to meet the standards which apply to the partic- U-G3FF
ular application, e.g. IEC 60204. The instructions for the intended use, the selection and the
Mounting plate for connection to flat ca-
Rotary encoders

correct connection of the sensors or the selection and the attainment of the corresponding
ble (AS-Interface and external auxiliary
safety category are given in the manual.
power)
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 99
VAA-2E2A-KE1-S/E2

AS-Interface safety module VAA-2E2A-KE1-S/E2


Dimensions
Masters and
Gateways

50.5
22.5 48.5
Extender, Repeaters
Power Supplies,

99.6
Safety at work
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

2 safety-oriented inputs S1 ... S2

AS-Interface - S+1
Switch
S-1
Field application

AS-Interface +
I/O Modules

Order code S+2


Switch
S-2
VAA-2E2A-KE1-S/E2
KE1-Safety module for the control cabi-
net ADDR
Analogue modules

2 safety-related inputs and


2 conventional electronic outputs
2 outputs OUT1 ... OUT2
Features O1
• 2 inputs for mechanical contacts such Load
PWR O-1
as EMERGENCY-STOP switch
FAULT
• Housing with removable terminals
Other modules

O2
Load
• Communication monitoring O-2
AUX
• Power supply of outputs from the AUX +
external auxiliary voltage AUX -
• Power supply of inputs from the
Inductive sensors

module
• Function display for bus, ext. auxiliary
voltage, inputs and outputs
• Output overload monitoring Indicating/operating means
• Switchable internal logic operation of
the inputs and outputs via parameter
Photoelectric

S+1 S-1 S+2 S-2


bit
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

S
FAULT
1 2

S
Rotary encoders

PWR AUX
ADDR

1 2
OUT

01 0 1 02 0 2
Accessories

AS-i + AS-i AUX+ AUX

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
100 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety module VAA-2E2A-KE1-S/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-2E2A-KE1-S/E2 is an AS-Interface
Slave type Standard slave
safety module with 2 safety-related inputs
Indicators/operating means and 2 conventional outputs. A dual channel
LED FAULT error display; LED red mechanical switch or in each case a single
red: communication error or address is 0
red flashing: Output supply overload
channel mechanical switch can be con-
nected to the two safety-related inputs. The

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green
outputs are conventional electronic outputs,
LED IN switching state (input); 2 LED yellow
which may be loaded in total with 1 A (max.
LED OUT switching state (output); 2 LED yellow
0,5 A per output).
The housing, only 22.5 mm in width and
Electrical specifications
48.5 mm in height, takes up little place in the
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
switch cabinet. The module features an inte-
Protection class III
grated addressing jack is mounted by snap-

Safety at work
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
ping onto the 35 mm DIN rail in accordance
Rated operational current Ie ≤ 70 mA
with EN 50022. Plug-in terminals are used
for connection. A 4-way terminal block
Input
(black) is used for the inputs. The AS-Inter-
Number/Type 2 safety-related inputs for mechanical contacts, cross-circuit
monitored: 2 single-channel contacts: up to category 2 to EN
face is connected via a double terminal block
954-1 or 1 2-channel contact: up to category 4 to EN 954-1 (yellow).
Cable length must exceed 30 m per input. The current switching state of each channel

Control cabinet
Supply from AS-Interface is indicated by an LED, located on the mod-

I/O Modules
Voltage 20 ... 30 V DC pulsed ule's top side. Similarly, an LED is provided
Current loading capacity input current limited ≤ 15 mA, to monitor the AS-Interface communication
overload and short-circuit resistant and to indicate that the module has the
Output address 0. If a communication error occurs,
Number/Type 2 conventional electronic outputs, PNP the outputs are de-energized (only P0=1).
Supply from external auxiliary voltage UAUX When single channel force-directed mechan-

Field application
Current 0.5 A per output ical switches are connected, up to

I/O Modules
Voltage ≥ (UAUX - 0,5 V) Category 2 in accordance with EN 954-1 can
Programming instructions be achieved, given the appropriate wiring
Profile S-7.B and selection of switch.
IO code 7 When a two-channel force-directed mechani-
ID code B cal switch is connected, up to Category 4 in

Analogue modules
ID1 code F accordance with EN 954-1 can be achieved,
ID2 code 0 given the appropriate wiring and selection of
Data bits (function via AS-Interface) input output switch.
D0 dyn. safety code S1 OUT 1 As per approval in accordance with
D1 dyn. safety code S1 OUT 2 IEC 61508 up to SIL 3 can be achieved.
D2 dyn. safety code S2 - Both inputs of the module are assigned. The
D3 dyn. safety code S2 - two channels of the mechanical switch are
Parameter bits (programmable via AS-i) function monitored for a cross circuit. LEDs are also

Other modules
P0 Logic operation: provided to indicate AS-Interface voltage and
P0 = 1 (Basic setting): The outputs are controlled via AS-Inter- external power supply.
face.
P0 = 0: The outputs are controlled via AS-Interface or the
inputs. The corresponding output is activated on opening the Accessories
contacts of an input.
P1 ... P3 not used VBP-HH1

Inductive sensors
Standard conformity Hand-held programming device
Insulation coordination EN 50178
Electromagnetic compatibility EN 50295, EN 61326, EN 61496-1, EN 61000-6-2, EN 61000-
VAZ-PK-1,5M-V1-G
4-5 1kV asymmetric, criterion B Connection cable module/hand-held pro-
Protection degree EN 60529 gramming device
Fieldbus standard EN 50295, IEC 62026-2
Functional safety EN 954-1:1996 (up to category 4), BIA Final Draft "Proposal
for a principle to the verification and certification of field busses
Photoelectric

for transmission of safety related signals" 28.05.2000,


sensors

IEC 61508 up to SIL3


Standards IEC 60204-1
Ambient conditions
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Ambient temperature -25 ... 50 °C (248 ... 323 K)


Storage temperature -25 ... 85 °C (248 ... 358 K)
Rotary encoders

Mechanical specifications
Protection degree IP20
Connection removable terminals, terminal connection ≤ 2.5 mm2
Mass 80 g
Mounting DIN rail

Notes
The cables and the laying of the cables have to meet the standards which apply to the partic-
Accessories

ular application, e.g. IEC 60204. The instructions for the intended use, the selection and the
correct connection of the sensors/actuators or the selection and the attainment of the corre-
sponding safety category are given in the manual.
The outputs may not be used for safety-related functions!

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 101
VAA-2E-KE1-S

AS-Interface safety module VAA-2E-KE1-S


Dimensions
Masters and
Gateways

50.5
22.5 48.5
Extender, Repeaters
Power Supplies,

99.6
Safety at work
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

2 safety-oriented inputs S1 ... S2

AS-Interface - S+1
Switch
S-1
Field application

AS-Interface +
I/O Modules

Order code S+2


Switch
S-2
VAA-2E-KE1-S
KE1 safety module for the control cabi-
net ADDR
Analogue modules

2 Safety-related inputs

Features
• 2 inputs for mechanical contacts such
PWR
as EMERGENCY-STOP switch
FAULT
• Housing with removable terminals
Other modules

• Communication monitoring
• Power supply of inputs from the
module
• Function display for bus and inputs
Inductive sensors

• Cross-circuit detection

Indicating/operating means

S+1 S-1 S+2 S-2


Photoelectric
sensors

S
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 2
S
FAULT
Rotary encoders

PWR
ADDR
Accessories

AS-i + AS-i

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
102 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface safety module VAA-2E-KE1-S
Technical data Function

Masters and
General specifications

Gateways
The VAA-2E-KE1-S is an AS-Interface safety
Slave type Standard slave
module with 2 safety-related inputs. A dual
Indicators/operating means channel mechanical switch or in each case a
LED FAULT error display; LED red single channel mechanical switch can be
red: communication error or address is 0
connected to the two inputs.
LED PWR AS-Interface voltage; LED green
The housing, only 22.5 mm in width and

Extender, Repeaters
LED IN switching state (input); 2 LED yellow

Power Supplies,
48.5 mm in height, takes up little place in the
Electrical specifications switch cabinet. The module features an inte-
Protection class III grated addressing jack is mounted by snap-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface ping onto the 35 mm DIN rail in accordance
Rated operational current Ie ≤ 70 mA with EN 50022. Plug-in terminals are used
Input for connection. A 4-way terminal block
Number/Type 2 safety-related inputs for mechanical contacts, cross-circuit (black) is used for the inputs. The AS-Inter-
monitored:

Safety at work
face is connected via a double terminal block
2 single-channel contacts: up to category 2 to EN 954-1 or
1 2-channel contact: up to category 4 to EN 954-1
(yellow).
Cable length must exceed 30 m per input. The current switching state of each channel
Supply from AS-Interface is indicated by an LED, located on the mod-
Voltage 20 ... 30 V DC pulsed ule's top side. Similarly, an LED is provided
Current loading capacity input current limited ≤ 15 mA, to monitor the AS-Interface communication
overload and short-circuit resistant and to indicate that the module has the

Control cabinet
address 0.

I/O Modules
Programming instructions
Profile S-0.B When single channel force-directed mechan-
IO code 0 ical switches are connected, up to
ID code B Category 2 in accordance with EN 954-1 can
ID1 code F be achieved, given the appropriate wiring
ID2 code 0 and selection of switch.
Data bits (function via AS-Interface) input output When a two-channel force-directed mechani-

Field application
cal switch is connected, up to Category 4 in

I/O Modules
D0 dyn. safety code S1 -
D1 dyn. safety code S1 - accordance with EN 954-1 can be achieved,
D2 dyn. safety code S2 - given the appropriate wiring and selection of
D3 dyn. safety code S2 - switch.
Parameter bits (programmable via AS-i) function As per approval in accordance with
P0 not used IEC 61508 up to SIL 3 can be achieved.

Analogue modules
P1 not used Both inputs of the module are assigned. The
P2 not used two channels of the mechanical switch are
P3 not used monitored for a cross circuit. A LED is also
Standard conformity provided to indicate AS-Interface voltage.
Insulation coordination EN 50178
Electromagnetic compatibility EN 50295, EN 61326, EN 61496-1, EN 61000-6-2, EN 61000- Accessories
4-5 1kV asymmetric, criterion B
Protection degree EN 60529 VBP-HH1

Other modules
Fieldbus standard EN 50295, IEC 62026-2 Hand-held programming device
Functional safety EN 954-1:1996 (up to category 4), BIA Final Draft "Proposal
for a principle to the verification and certification of field busses VAZ-PK-1,5M-V1-G
for transmission of safety related signals" 28.05.2000, Connection cable module/hand-held pro-
IEC 61508 up to SIL3
Standards IEC 60204-1
gramming device
Ambient conditions

Inductive sensors
Ambient temperature -25 ... 50 °C (248 ... 323 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree IP20
Connection removable terminals, terminal connection ≤ 2.5 mm2
Mass 80 g
Mounting DIN rail
Photoelectric
sensors

Notes
The cables and the laying of the cables have to meet the standards which apply to the partic-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

ular application, e.g. IEC 60204. The instructions for the intended use, the selection and the
correct connection of the sensors or the selection and the attainment of the corresponding
safety category are given in the manual.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 103
VAA-2E-F85-V1

AS-Interface emergency off button VAA-2E-F85-V1


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,

66.5
80
Safety at work

58.6 ø4.5 20
72 56
Control cabinet

Electrical connection
I/O Modules

SAFETY AT WORK

AS-Interface +
-PrüfZ 1
BG

ert

01097
2 4
Field application
I/O Modules

Order code 3
AS-Interface -
VAA-2E-F85-V1
AS-Interface emergency off button
Technical data
Analogue modules

General specifications
Slave type Standard slave
Features Electrical specifications
Protection class III
• Protection degree IP65 and IP69k Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
• Outwit-proof according to Rated operational current Ie ≤ 20 mA
ISO 13850/EN 418 Input
Other modules

Number/Type 2 NC
• 2-channel, compelled connected Safety function with positive opening operation in accordance
with IEC/EN 60947-5-1 Reset on pulling
• TÜV-approval for system
Supply from AS-Interface
components is available
Programming instructions
Profile S-7.B.E
Function
Inductive sensors

IO code 7
When used in accordance with conditions in ID code B
combination with an AS-Interface safety ID1 code 0
monitor, this AS-Interface EMERGENCY ID2 code E
OFF makes it possible to operate personal Data bits (function via AS-Interface) input output
protection equipment. D0 dyn. safety code S1 -
D1 dyn. safety code S1 -
D2 dyn. safety code S2 -
Photoelectric

Accessories D3 dyn. safety code S2 -


sensors

Parameter bits (programmable via AS-i) function


VAZ-F85-SH
P0 not used
Actuating protection
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P1 not used
P2 not used
P3 not used
Rotary encoders

Ambient conditions
Ambient temperature -25 ... 55 °C (248 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree IP65 according to EN 60529 and IP69k
Connection M12 round connector
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
104 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
105
Notes

Accessories Rotary encoders Photoelectric Inductive sensors Other modules Analogue modules I/O Modules I/O Modules Safety at work Power Supplies, Masters and
sensors Field application Control cabinet Extender, Repeaters Gateways
AS-Interface - Coupling modules
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
106 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Coupling modules

5 Coupling modules

Masters and
Gateways
AS-Interface coupling modules enable even conventional sensors to be
connected to AS-Interface and still achieve significant installation advantag-
es compared to traditional wiring. To handle different applications, there are
a wide variety of versions available:

Extender, Repeaters
Power Supplies,
• Pure input modules (Sensors supplied with power from AS-Interface)
• Modules with inputs and outputs (power supply through AS-Interface or
external)
• Modules with relays or triac outputs for high current consumption

Safety at work
• Modules for connection of two-wire sensors or contacts
• Modules for connection of analogue signals
(0 V ... 10 V/0 mA... 20 mA/PT100)
• Modules in PNP technology (switched high)
(Modules in NPN technology on request)

Control cabinet
I/O Modules
• Modules with different connection systems
• Modules with special approval (intrinsically safe modules/Ex modules)
• Diverse designs with different protection classes from IP20 to IP67.

Field application
With the new AS-Interface specification 2.1, up to 62 modules can be con-

I/O Modules
nected to a single AS-Interface network, serving up to 248 inputs and
186 outputs. When using AS-Interface integrated sensors, up to 62 sensors
can operate on a single network.
With its broad spectrum of I/O modules for the switch cabinet, junction box-

Analogue modules
es, and field applications, Pepperl+Fuchs offers a fitting design for every ap-
plication.

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 107
AS-Interface - Switch cabinet and junction box modules
5.1 Switch cabinet and junction box modules
Masters and
Gateways

The KF series, with only a 20 mm widht, provides 4 short-circuit protected


inputs, or with a 40 mm width, 4 short-circuit protected inputs and 4 short-
circuit protected outputs. A function indicator is available for each channel.
The outputs can drive up to 2 A per output and have an external power sup-
Extender, Repeaters

ply. If no AS-Interface communication occurs, parameter bit P0 can be used


Power Supplies,

to set whether the outputs should then be powered down within 80 ms.
Connection is performed using pluggable coded terminal blocks, guaran-
teeing fast and error-free exchanges. The terminals can also be connected
under power. The maximum allowable wire size is 2.5 mm2.
The KF modules can simply be popped onto the 35 mm DIN rail (as per EN
Safety at work

50022) in the switch cabinet and connected via Power Rail, so that, for in-
stance, only the master in the KF housing must be wired to the AS-Interface
flat cable. To do this, either the inset component PR-05 in 0.5 m lengths for
the DIN rail is required, or UPR-05 continuous complete rails including DIN
rail (2 m lengths, may be cut) can be used.
Control cabinet
I/O Modules

In the KF housing there is also a data coupler available which can transmit
4 bits of data from one AS-Interface network to a second network.

Alternatively, modules of the KE series can be used in the switch cabinet.


In this type, up to 4 inputs and 3 outputs are provided in only 22.5 mm width.
Field application
I/O Modules

The KE series also features coloured terminal blocks, making connection


particularly simple:
yellow: AS-Interface
black: Inputs/Outputs
Analogue modules

gray: 24 V DC power supply


red: relay outputs.
The Power Rail connection is not supported by the KE series.

In decentralised installations, flat junction boxes are often used in order to


Other modules

connect to contacts or sensors. The KE1 series is suitable for this use, with
up to 4 inputs and 2 outputs in only 22.5 mm of width and 50 mm of height.
Power supply is accomplished over the AS-Interface and the KE1 modules
are easy to pop onto the DIN rails. The terminals are colour-coded to pre-
vent confusion.
Inductive sensors

The somewhat taller housings of the KE2 series, with two rows of terminals,
can be used, for example, with analoguemodules in the switch cabinet.

If 3-wire sensors are attached to a junction box, or power is externally sup-


plied, the K3 series is the right solution. In a width of 71 mm and a height of
Photoelectric
sensors

only 40 mm, up to 4 inputs and 3 outputs can be connected. A version with


relay output is also available.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Connection is performed by screw terminals (wire size max. 2.5 mm2).


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
108 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Switch cabinet and junction box modules
Overview of switch cabinet and junction box modules

Masters and
Gateways
(Sorted by design. Dimensions and connection type can be found in the corresponding data sheets.)

Design Type code Inputs Outputs External power supply Page

Extender, Repeaters
VAA-4EA-KF-ZE/E2 4 4 Inputs and outputs (VAUX) 110

Power Supplies,
VAA-4EA-KF-ZE/R 4 4 relays Inputs and outputs 112

KF
VAA-4E-KF-ZE 4 - Inputs 114

Safety at work
VAA-4A-KF-E2 - 4 Outputs (VAUX) 116

VAA-4EA-KF-DK Data coupler - 118

Control cabinet
VAA-4EA-KF2-ZE/E2 4 4 Outputs (VAUX) 120

I/O Modules
VAA-4EA-KF2-ZE/R 4 4 relays Inputs and outputs 122

VAA-4EA-KF2-ZE/T 4 4 Outputs (VAUX) 124


KF2

Field application
I/O Modules
VAA-4E-KF2-ZE 4 - - 126

Analogue modules
Inputs as required (VEXT)
VBA-4E3A-KE-ZE/E2 4 3 128
and outputs (VAUX)
Inputs as required (VEXT)
VBA-4E3A-KE-ZE/R 4 3 relays 130
and outputs

KE VBA-4E-KE-ZE 4 - Inputs as required (VEXT) 134

Other modules
Inputs as required (VEXT)
VAA-4E4A-KE-ZE/E2 4 4 136
and outputs (VAUX)
Inputs as required (VEXT)
VAA-4E4A-KE-ZE/R 4 4 relays 138
and outputs

Inductive sensors
VBA-4E2A-KE1-Z/E2 4 two-wire 2 Outputs (VAUX) 142

KE1
VBA-4E-KE1-Z 4 two-wire - - 144 Photoelectric

VAA-4EA-K3-ZE/E2 4 4 Inputs and outputs (VAUX) 146


sensors

K3
VAA-4A-K3-R - 4 relays Outputs 148
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Modules in NPN technology (current sinking) upon request.


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 109
VAA-4EA-KF-ZE/E2

AS-Interface sensor-/actuator module VAA-4EA-KF-ZE/E2


Dimensions
Masters and
Gateways

40 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules


+ 24 V PELV
13
Field application

+IN1
I/O Modules

2
AS-Interface - 15
Order code 8 +IN2
AS-Interface -
1 19
VAA-4EA-KF-ZE/E2 AS-Interface + +IN3
7
AS-Interface + 21
Cabinet module +IN4
4 inputs (PNP) and 4 electronic outputs 14
Analogue modules

20 -IN for 3-wire


sensors
16
+OUT1
Features 18
+OUT2
• AS-Interface certificate ADDR
22
+OUT3 Load
• Housing with removable, coded
5 24
terminals
Other modules

+OUT4
Power 4 17
• AS-Interface connection via Power Rail 23 -OUT
Rail 3 4
PWR/ 6 -AUX for connection
• Communication monitoring, turn-off FAULT 5
10 +AUX of UAUX
• Outputs loadable up to 8 A (per
Inductive sensors

module)
• Addressing jack
• Power supply of outputs from the
external auxiliary voltage Indicating/operating means
• External power supply of sensors
• Function display for bus, ext. auxiliary 1 2 3 4 5 6
Photoelectric

voltage, inputs and outputs 7 8 9 10 11 12


sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

IN1 IN2 OUT1 OUT2

IN3 IN4 PWR/ OUT3 OUT4 AUX


FAULT
13 14 15 16 17 18
Accessories

19 20 21 22 23 24

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
110 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-KF-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-KF-ZE/E2 AS-Interface cou-
Slave type Standard slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 4 electronic outputs. Its design,
LED PWR/FAULT dual-LED green/red only 40 mm wide, occupies little space in a
green: AS-Interface voltage, normal operation
red: communication error or address 0
cabinet installation. The VAA-4EA-KF-ZE/E2
is installed by snapping it onto the 35 mm

Extender, Repeaters
LED AUX ext. auxiliary voltage UAUX; LED green

Power Supplies,
LED IN switching state (input); 4 LED yellow
DIN Rail per EN 50022, with the integrated
LED OUT switching state (output); 4 LED yellow
Power Rail.
When an AS-Interface master/gateway is
Electrical specifications
used in the cabinet housing, the AS-Interface
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
signal is automatically transmitted via the
Protection class III
Power Rail. The connection of the module to
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
the AS-Interface cable is accomplished by
Rated operational current Ie ≤ 30 mA

Safety at work
simply snapping it onto the DIN Rail.
Input The plug-in coded terminals of the inputs and
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC outputs allow "online" maintenance, i. e.
Supply external while the system is under power. The termi-
Switching point nals are coded to prevent incorrect connec-
0 (unattenuated) ≤ 2 mA tions.
1 (attenuated) ≥ 4 mA If a master/gateway other than the one in the

Control cabinet
Output cabinet housing is used, the connection to

I/O Modules
Number/Type 4 electronic outputs, PNP the AS-Interface cable is established via the
Supply from external auxiliary voltage UAUX same terminals. Once the AS-Interface cable
Current 2 A per output , 8 A per module has been connected to the terminals, the AS-
Voltage ≥ (UAUX - 0,5 V) Interface signal is automatically transferred
Programming instructions to the Power Rail.
Profile S-7.F Power to the module is supplied by the AS-

Field application
Interface cable and the inputs and outputs

I/O Modules
IO code 7
ID code F are powered externally (see connection dia-
Data bits (function via AS-Interface) input output gram). A programming jack is available for
D0 IN1 OUT1 address configuration.
D1 IN2 OUT2 Note:
D2 IN3 OUT3 The outputs are de-energised by means of

Analogue modules
D3 IN4 OUT4 an integrated watchdog, whenever communi-
Parameter bits (programmable via AS-i) function cation on the AS-Interface cable is inter-
P0 communication monitoring rupted for more than 80 ms. The watchdog
P0 = 1 (basic setting), monitoring = ON, i.e. if communication can be disabled by the parameter bit P0.
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs
maintain their condition Accessories
P1 not used
UPR-E

Other modules
P2 not used
P3 not used End cap for UPR-03 und UPR-05
Ambient conditions
VBP-HH1
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications VAZ-PK-1,5M-V1-G
Connection cable module/hand-held pro-

Inductive sensors
Protection degree IP20 according to EN 60529
Connection removable coded terminals, Power Rail gramming device
Mass 170 g
Mounting DIN rail UPR-05
Universal Power Rail with DIN rail and
cover, 5 leads
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 111
VAA-4EA-KF-ZE/R

AS-Interface sensor-/actuator module VAA-4EA-KF-ZE/R


Dimensions
Masters and
Gateways

40 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules


+ 24 V PELV
13
Field application

2 IN1
AS-Interface -
I/O Modules

8
AS-Interface - 15
Order code IN2
1
AS-Interface +
VAA-4EA-KF-ZE/R 19
7 IN3
AS-Interface +
Cabinet module 21
IN4
4 inputs (PNP) and 4 relay outputs 14
Analogue modules

20 -IN for 3-wire


sensors

Features ADDR 4
6 OUT1
• AS-Interface certificate 5
10
• Housing with removable, coded Power 12
OUT2
terminals Rail 11
Other modules

16
• AS-Interface connection via Power 18 OUT3
17
Rail 22
Back-
24 OUT4
• Communication monitoring, turn-off side PWR/ 23
FAULT
• Outputs loadable up to 8 A (per
Inductive sensors

module)
• Addressing jack
• External power supply of sensors
Indicating/operating means
• Function display for bus, inputs and
outputs
• 4 potential-free switch-contacts 1 2 3 4 5 6
Photoelectric

7 8 9 10 11 12
sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

IN1 IN2 OUT1 OUT2

IN3 IN4 PWR/ OUT3 OUT4


FAULT
13 14 15 16 17 18
Accessories

19 20 21 22 23 24

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
112 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-KF-ZE/R
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-KF-ZE/R AS-Interface cou-
Slave type Standard slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 4 relay outputs. Its design, only
LED PWR/FAULT dual-LED green/red 40 mm wide, occupies little space in a cabi-
green: AS-Interface voltage, normal operation
red: communication error or address 0
net installation. The VAA-4EA-KF-ZE/R is
installed by snapping it onto the 35 mm DIN

Extender, Repeaters
LED IN switching state (input); 4 LED yellow

Power Supplies,
LED OUT switching state (output); 4 LED yellow
Rail per EN 50022, with the integrated Power
Rail.
Electrical specifications
When an AS-Interface master/gateway is
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
used in the cabinet housing, the AS-Interface
Rated operational current Ie ≤ 110 mA
signal is automatically transmitted via the
Input Power Rail. The connection of the module to
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC the AS-Interface cable is accomplished by
Supply external

Safety at work
simply snapping it onto the DIN Rail.
Switching point The plug-in coded terminals of the inputs and
0 (unattenuated) ≤ 2 mA outputs allow "online" maintenance, i. e.
1 (attenuated) ≥ 4 mA while the system is under power. The termi-
Output nals are coded to prevent incorrect connec-
Number/Type 4 relay outputs tions.
Electrical isolation AS-Interface - Outputs: Safe isolation according to EN 50178 If a master/gateway other than the one in the

Control cabinet
(250 V AC) cabinet housing is used, the connection to

I/O Modules
Output - Output: Safe isolation according to EN 50178 (250 V
AC) the AS-Interface cable is established via the
Contact loading 2 A/30 V DC per output same terminals. Once the AS-Interface cable
2 A/250 V AC per output has been connected to the terminals, the AS-
Lifetime mechanical: 30 x 106 switching cycles Interface signal is automatically transferred
electrical: to the Power Rail.
1 x 106 operations (30 V DC, 2 A, ohmic) Power to the module is supplied by the AS-

Field application
5 x 106 operations (250 V AC, 2 A, cosϕ = 1)
Interface cable and the inputs and outputs

I/O Modules
4.5 x 106 switching cycles(250 V AC, 2 A, cosϕ = 0.7)
are powered externally (see connection dia-
Programming instructions
gram). A programming jack is available for
Profile S-7.F
address configuration.
IO code 7
Note:
ID code F
The outputs are de-energised by means of
Data bits (function via AS-Interface) input output

Analogue modules
an integrated watchdog, whenever communi-
D0 IN1 OUT1
cation on the AS-Interface cable is inter-
D1 IN2 OUT2
rupted for more than 80 ms. The watchdog
D2 IN3 OUT3
can be disabled by the parameter bit P0.
D3 IN4 OUT4
Parameter bits (programmable via AS-i) function
P0 communication monitoring Accessories
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
fails, the outputs are de-energised VBP-HH1

Other modules
P0 = 0, monitoring = OFF, if communication fails, the outputs Hand-held programming device
maintain their condition
P1 not used UPR-05
P2 not used Universal Power Rail with DIN rail and
P3 not used
cover, 5 leads
Ambient conditions
VAZ-PK-1,5M-V1-G

Inductive sensors
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) Connection cable module/hand-held pro-
Mechanical specifications gramming device
Protection degree IP20 according to EN 60529
Connection removable coded terminals, Power Rail
UPR-E
Mass 170 g End cap for UPR-03 und UPR-05
Mounting DIN rail
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 113
VAA-4E-KF-ZE

AS-Interface sensor module VAA-4E-KF-ZE


Dimensions
Masters and
Gateways

20 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules


+ 24 V PELV
Field application

2
I/O Modules

5 AS-Interface - 7
Order code +IN1
1
VAA-4E-KF-ZE 4 AS-Interface +

Cabinet module 9
4 inputs (PNP) +IN2
Analogue modules

ADDR 10
Features +IN3

• AS-Interface certificate 5
• Housing with removable, coded Power 4 12
+IN4
terminals Rail
Other modules

3
• AS-Interface connection via Power 8
Rail PWR/ 11 -IN
FAULT for 3-wire
• Addressing jack sensors
• External power supply of sensors
Inductive sensors

• Function display for bus and inputs

Indicating/operating means

1 2 3
Photoelectric

4 5 6
sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

IN1 IN2

IN3 IN4 PWR/


FAULT
7 8 9
Accessories

10 11 12

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
114 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VAA-4E-KF-ZE
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E-KF-ZE AS Interface coupling
Slave type Standard slave
module is a cabinet module with 4 inputs.
Indicators/operating means The design, only 20 mm wide, occupies little
LED PWR/FAULT dual-LED green/red space in a cabinet installation. The VAA-4E-
green: AS-Interface voltage, normal operation
red: communication error or address 0
KF-ZE is installed by snapping it onto the
35 mm DIN rail per EN 50022, with the inte-

Extender, Repeaters
LED IN switching state (input); 4 LED yellow

Power Supplies,
grated Power Rail.
Electrical specifications
When an AS-Interface master/gateway is
Protection class III
used in the cabinet housing, the AS-Interface
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
signal is automatically transmitted via the
Rated operational current Ie ≤ 20 mA
Power Rail. The connection of the module to
Input the AS-Interface cable is accomplished by
Number/Type 4 inputs for sensors (PNP), DC simply snapping it onto the DIN rail.
Supply external

Safety at work
The plug-in coded terminals of the inputs
Switching point allow "online" maintenance, i. e. while the
0 (unattenuated) ≤ 2 mA system is under power. The terminals are
1 (attenuated) ≥ 4 mA coded to prevent incorrect connections.
Programming instructions If a master/gateway other than the one in the
Profile S-0.0 cabinet housing is used, the connection to
IO code 0 the AS-Interface cable is established via the

Control cabinet
ID code 0 same terminals. Once the AS-Interface cable

I/O Modules
Data bits (function via AS-Interface) input output has been connected to the terminals, the AS-
D0 IN1 - Interface signal is automatically transferred
D1 IN2 - to the Power Rail.
D2 IN3 - Power to the module is supplied by the AS-
D3 IN4 - Interface cable and the outputs are powered
Parameter bits (programmable via AS-i) function externally (see connection diagram). A pro-

Field application
P0 not used gramming jack is available for address con-

I/O Modules
P1 not used figuration.
P2 not used
P3 not used
Accessories
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K) VBP-HH1

Analogue modules
Storage temperature -25 ... 85 °C (248 ... 358 K) Hand-held programming device
Mechanical specifications
Protection degree IP20 according to EN 60529
VAZ-PK-1,5M-V1-G
Connection removable coded terminals, Power Rail Connection cable module/hand-held pro-
Mass 130 g gramming device
Mounting DIN rail
UPR-05
Universal Power Rail with DIN rail and

Other modules
cover, 5 leads
UPR-E
End cap for UPR-03 und UPR-05

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 115
VAA-4A-KF-E2

AS-Interface actuator module VAA-4A-KF-E2


Dimensions
Masters and
Gateways

20 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules


Field application

2
AS-Interface -
I/O Modules

8
AS-Interface -
Order code 1
7 OUT1
AS-Interface +
VAA-4A-KF-E2 AS-Interface +
7

Cabinet module
9 OUT2
4 electronic outputs
Analogue modules

Load
10 OUT3
Features
ADDR
• Housing with removable, coded
terminals 5 12 OUT4
• AS-Interface connection via Power
Other modules

Power 4
8
Rail Rail
11 0V
3
• Communication monitoring, turn-off PWR/ 3 AE- for connection
FAULT AE 6
• Outputs loadable up to 8 A (per AE+ of UAUX
module)
Inductive sensors

• Addressing jack
• Power supply of outputs from the
external auxiliary voltage
• Function display for bus, external Indicating/operating means
auxiliary voltage and outputs
+ - AE-
AS-i
Photoelectric

+ - AE+
sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

OUT1 OUT2 AE

OUT3 OUT4 PWR/


FAULT
OUT1 0V OUT2
Accessories

OUT3 0V OUT4

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
116 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface actuator module VAA-4A-KF-E2
Technical data Function

Masters and
Indicators/operating means

Gateways
The VAA-4A-KF-E2 AS-Interface coupling
LED PWR/FAULT dual-LED green/red
module is a cabinet module with 4 electronic
green: AS-Interface voltage, normal operation
red: communication error or address 0 outputs. Its design, only 20 mm wide, occu-
LED OUT switching state (output); 4 LED yellow pies only little space in a cabinet installation.
LED AE ext. auxiliary voltage UAUX; LED green The VAA-4E-KF-E2 is installed by snapping it
onto a 35 mm DIN rail according to

Extender, Repeaters
Electrical specifications

Power Supplies,
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
EN 50022, with the integrated Power Rail.
Protection class III
When an AS-Interface master/gateway is
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
used in the cabinet housing, the AS-Interface
Rated operational current Ie ≤ 30 mA
signal is automatically transmitted via the
Power Rail. The connection of the module to
Output
the AS-Interface cable is accomplished by
Number/Type 4 electronic outputs, PNP
simply snapping it onto the DIN rail.
Supply from external auxiliary voltage UAUX

Safety at work
The plug-in coded terminals of the inputs and
Current 2 A per output , 8 A per module
outputs allow "online" maintenance, i. e.
Voltage ≥ (UAUX - 0,5 V)
while the system is under power. The termi-
Programming instructions nals are coded to prevent incorrect connec-
Profile S-8.F tions.
IO code 8 If a master/gateway other than the one in the
ID code F cabinet housing is used, the connection to

Control cabinet
Data bits (function via AS-Interface) input output the AS-Interface cable is established via the

I/O Modules
D0 IN4 O4 same terminals. Once the AS-Interface cable
D1 - OUT2 has been connected to the terminals, the AS-
D2 - OUT3 Interface signal is automatically transferred
D3 - OUT4 to the Power Rail.
Parameter bits (programmable via AS-i) function Power to the module is supplied by the AS-
P0 communication monitoring Interface cable and the outputs are powered

Field application
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
externally (see connection diagram). A pro-

I/O Modules
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs gramming jack is available for address con-
maintain their condition figuration.
P1 not used Note:
P2 not used The outputs are de-energised via an inte-
P3 not used grated watchdog, whenever communication

Analogue modules
Ambient conditions on the AS-Interface cable is interrupted for
Ambient temperature -25 ... 70 °C (248 ... 343 K) more than 80 ms. The watchdog can be disa-
Storage temperature -25 ... 85 °C (248 ... 358 K) bled by the P0 parameter bit.
Mechanical specifications
Protection degree IP20 according to EN 60529 Accessories
Connection removable coded terminals, Power Rail
Mass 130 g VBP-HH1
Hand-held programming device

Other modules
Mounting DIN rail

VAZ-PK-1,5M-V1-G
Connection cable module/hand-held pro-
gramming device
UPR-05

Inductive sensors
Universal Power Rail with DIN rail and
cover, 5 leads
UPR-E
End cap for UPR-03 und UPR-05 Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 117
VAA-4EA-KF-DK

AS-Interface data coupler VAA-4EA-KF-DK


Dimensions
Masters and
Gateways

20 114

Terminal for wall mounting


Extender, Repeaters
Power Supplies,

107
93
Safety at work
Control cabinet

Electrical connection
I/O Modules

U
®
Field application

5
I/O Modules

AS-Interface 2-
Order code 010 6 AS-Interface 2+
011
VAA-4EA-KF-DK AS-Interface 1 -
1 8 AS-Interface 2-
012
Cabinet module AS-Interface 1 + 2 9
013 AS-Interface 2+
Analogue modules

Features ADDR1 ADDR2


• Module for bi-directional data
exchange between two AS-Interface 4
Power 020
circuits
Other modules

Rail 5 021
• 2 AS-Interface connections 022
• 4 inputs/4 outputs per slave 023
PWR1 PWR2
(internally connected)
• AS-Interface-connection 1 via Power
Rail
Inductive sensors

• Housing with removable, coded


terminals
• Function display for all outputs Indicating/operating means
• Addressing via 2 sockets in the front
plate
Photoelectric
sensors

1 2 3

ADDR1
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

010 011 PWR1


AS-Interface-circuit 1
012 013
Rotary encoders

022 023

020 021 PWR2

AS-Interface-circuit 2

ADDR2
Accessories

4 5 6
7 8 9

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
118 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface data coupler VAA-4EA-KF-DK
Technical data Function

Masters and
General specifications

Gateways
The data coupler interface module VAA-4EA-
Slave type Standard slave
KF-DK is used when the output bits of an
Indicators/operating means AS-Interface circuit are to be used as the
LED PWR AS-Interface voltage; 2 LED green input bits of another AS-Interface circuit. The
LED OUT switching state (output); 8 LED yellow data coupler is equipped with two AS-Inter-
O10-O13: AS-Interface 1;
face connections for this purpose, each rep-

Extender, Repeaters
O20-O23: AS-Interface 2

Power Supplies,
resenting a 4EA module. The output bits of
Electrical specifications
the AS-Interface circuit 1 are represented on
Protection class III
the AS-Interface circuit 2 as input bits and
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
vice versa. This enables data exchange to be
Rated operational current Ie ≤ 30 mA
carried out in both directions without having
Input to transfer the data via the higher-level con-
Number/Type 4 internal inputs per AS-Interface circuit 1+2 trol system. This is a particular advantage in

Safety at work
Output time-critical applications. The addressing
Number/Type 4 internal outputs per AS-Interface circuit 1+2 procedures for the two integrated AS-Inter-
Programming instructions face slaves are carried out independently of
Profile S-7.F each other. Two addressing jacks are pro-
IO code 7 vided for this purpose.
ID code F Because two independent AS-Interface mod-
Data bits (function via AS-Interface) input output ules are used, the related inputs and outputs

Control cabinet
are galvanically isolated from each other.

I/O Modules
D0 IN1 OUT1
D1 IN2 OUT2 This avoids problems with potential shifts
D2 IN3 OUT3 (earth potential). The status of all the outputs
D3 IN4 OUT4 is indicated via 8 LEDs located on the mod-
Parameter bits (programmable via AS-i) ule's front panel. Two additional LEDs indi-
P0 not used cate the AS-Interface voltage on the two
P1 not used circuits.

Field application
Its design, only 20 mm wide, occupies little

I/O Modules
P2 not used
P3 not used space in a cabinet installation. The VAA-
Ambient conditions 4EA-KF-DK is installed by snapping it onto
Ambient temperature -25 ... 70 °C (248 ... 343 K) the 35 mm DIN rail per EN 50022, with the
Storage temperature -25 ... 85 °C (248 ... 358 K) inserted Power Rail. This ensures that AS-
Interface circuit 1 of the module is automati-
Mechanical specifications

Analogue modules
cally connected to the AS-Interface transmis-
Protection degree IP20 according to EN 60529
sion line, if other cabinet modules or a
Connection removable coded terminals, Power Rail
master/gateway are operating on this circuit.
Mass 130 g
If this is not the case, the AS-Interface trans-
Mounting DIN rail
mission line is connected to the pluggable,
coded terminals. This is absolutely essential
for AS-Interface circuit 2.

Other modules
Accessories
VBP-HH1
Hand-held programming device
VAZ-PK-1,5M-V1-G

Inductive sensors
Connection cable module/hand-held pro-
gramming device
UPR-05
Universal Power Rail with DIN rail and
cover, 5 leads
UPR-E
Photoelectric

End cap for UPR-03 und UPR-05


sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 119
VAA-4EA-KF2-ZE/E2

AS-Interface sensor-/actuator module VAA-4EA-KF2-ZE/E2


Dimensions
Masters and
Gateways

40 114
Terminal for wall mounting
Extender, Repeaters
Power Supplies,

111
118
93
Safety at work
Control cabinet

Electrical connection
I/O Modules


7
13
Field application

19 +IN
I/O Modules

2 AS-Interface - 25
Order code 1 AS-Interface + 8 +IN1
14
VAA-4EA-KF2-ZE/E2 +IN2
20 +IN3
Cabinet module
26 +IN4
4 inputs (PNP) and 4 electronic outputs
Analogue modules

9 for 3-wire
15
21 -IN sensors
27
11
Features +OUT1
ADDR 17
• Housing with removable, coded +OUT
terminals 5
23 +OUT Load

• AS-Interface connection via Power


Other modules

Power 29 +OUT4
4
Rail 12
Rail 18
3
24 -OUT
• Communication monitoring, turn-off PWR/ 30
FAULT 6
• Outputs loadable up to 8 A (per - AUX or connection
5 +AUX of UAUX
module)
Inductive sensors

• Inputs for 2- and 3-wire sensors


• Addressing jack
• Power supply of outputs from the
external auxiliary voltage Indicating/operating means
• Power supply of inputs from the
module 1 2 3 4 5 6
Photoelectric

• Function display for bus, ext. auxiliary 7 8 9 10 11 12


sensors

voltage, inputs and outputs ADDR


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IN1 IN2 OUT1 OUT2


Rotary encoders

IN3 IN4 PWR/ OUT3 OUT4 AUX


FAULT
13 14 15 16 17 18
19 20 21 22 23 24
Accessories

25 26 27 28 28 29

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
120 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-KF2-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-KF2-ZE/E2 AS-Interface cou-
Slave type Standard slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 4 electronic outputs. The VAA-
LED PWR/FAULT dual LED green/red 4EA-KF2-ZE/E2 is installed by snapping it
green: AS-Interface voltage
red: communication error or address 0
onto the 35 mm DIN Rail per EN 50022, with
the integrated Power Rail.

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green When an AS-Interface master/gateway is
LED IN switching state (input); 4 LED yellow used in the cabinet housing, the AS-Interface
LED OUT switching state (output); 4 LED yellow signal is automatically transmitted via the
Electrical specifications Power Rail. The connection of the module to
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
the AS-Interface cable is accomplished by
Protection class III
simply snapping it onto the DIN Rail.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
The plug-in coded terminals of the inputs and

Safety at work
Rated operational current Ie ≤ 50 mA (without sensors) / max. 200 mA
outputs allow "online" maintenance, i. e.
while the system is under power. The termi-
Input
nals are coded to prevent incorrect connec-
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
tions.
Supply from AS-Interface
If a master/gateway other than the one in the
Voltage 21 ... 31 V DC
cabinet housing is used, the connection to
Current loading capacity ≤ 150 mA, short-circuit protected
the AS-Interface cable is established via the

Control cabinet
Switching point
same terminals. Once the AS-Interface cable

I/O Modules
0 (unattenuated) ≤ 2 mA
has been connected to the terminals, the AS-
1 (attenuated) ≥ 4 mA
Interface signal is automatically transferred
Output to the Power Rail.
Number/Type 4 electronic outputs, PNP Power to the module and to the inputs is sup-
Supply from external auxiliary voltage UAUX plied by the AS-Interface cable and the out-
Current 2 A per output , 8 A per module puts are powered externally (see connection

Field application
Voltage ≥ (UAUX - 0,5 V) diagram). A programming jack is available for

I/O Modules
Programming instructions address configuration.
Profile S-7.F
IO code 7 Note:
ID code F The outputs are de-energised by means of
Data bits (function via AS-Interface) input output an integrated watchdog, whenever communi-

Analogue modules
D0 IN1 OUT1 cation on the AS-Interface cable is inter-
D1 IN2 OUT2 rupted for more than 80 ms. The watchdog
D2 IN3 OUT3 can be disabled by the parameter bit P0.
D3 IN4 OUT4 If a short circuit occurs in the sensor supply,
Parameter bits (programmable via AS-i) function the AS-Interface master will indicate an error
P0 communication monitoring and the module will disconnect from the AS-
P0 = 1 (basic setting), monitoring = ON, i.e. if communication Interface.
fails, the outputs are de-energised

Other modules
P0 = 0, monitoring = OFF, if communication fails, the outputs
maintain their condition
Accessories
P1 not used
P2 not used VBP-HH1
P3 not used Hand-held programming device
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
VAZ-PK-1,5M-V1-G

Inductive sensors
Storage temperature -25 ... 85 °C (248 ... 358 K) Connection cable module/hand-held pro-
Mechanical specifications gramming device
Protection degree IP20 according to EN 60529 UPR-05
Connection removable coded terminals, Power Rail
Universal Power Rail with DIN rail and
Mass 170 g
cover, 5 leads
Mounting DIN rail
UPR-E
Photoelectric

End cap for UPR-03 und UPR-05


sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 121
VAA-4EA-KF2-ZE/R

AS-Interface sensor-/actuator module VAA-4EA-KF2-ZE/R


Dimensions
Masters and
Gateways

40 114
Terminal for wall mounting
Extender, Repeaters
Power Supplies,

111
118
93
Safety at work
Control cabinet

Electrical connection
I/O Modules


7
13
Field application

2 AS-Interface - 19 +IN
I/O Modules

25
Order code 1 AS-Interface + 8
IN1
VAA-4EA-KF2-ZE/R 14 IN2
20 IN3
Cabinet module
26 IN4
4 inputs (NPN) and 4 relay outputs
Analogue modules

9
for 3-wire
15
21 -IN sensors
27

Features 10
ADDR 12
OUT1
• Housing with removable, coded 11
16
terminals 5 18 OUT2
17
• Function display for bus, inputs and Power
Other modules

4 22
Rail 24
outputs 3 23
OUT3
28
• 4 potential-free switch-contacts PWR/
30
FAULT
29
OUT4
• Addressing jack
• Communication monitoring, turn-off
Inductive sensors

• Outputs loadable up to 8 A (per


module)
• Inputs for 2- and 3-wire sensors
Indicating/operating means
• Power supply of inputs from the
module
• AS-Interface connection via Power 1 2 3 4 5 6
Photoelectric

Rail 7 8 9 10 11 12
sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IN1 IN2 OUT1 OUT2


Rotary encoders

IN3 IN4 PWR/ OUT3 OUT4


FAULT
13 14 15 16 17 18
19 20 21 22 23 24
Accessories

25 26 27 28 29 30

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
122 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-KF2-ZE/R
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-KF2-ZE/R AS-Interface cou-
Slave type Standard slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 4 relay outputs. Its design, only
LED PWR/FAULT dual LED green/red 40 mm wide, occupies little space in a cabi-
green: AS-Interface voltage
red: communication error or address 0
net installation. To install the VAA-4EA-KF2-
ZE/R, simply snap it onto the 35 mm DIN rail

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state (input); 4 LED yellow according to EN 50022, with the integrated
LED OUT switching state (output); 4 LED yellow Power Rail.
Electrical specifications When an AS-Interface master/gateway is
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
used in the cabinet housing, the AS-Interface
Rated operational current Ie ≤ 80 mA (without sensors) / max. 230 mA
signal is automatically transmitted via the
Power Rail. The connection of the module to
Input
the AS-Interface cable is accomplished by
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC

Safety at work
simply snapping it onto the DIN rail.
Supply from AS-Interface
The plug-in coded terminals of the inputs and
Voltage 21 ... 31 V DC
outputs allow "online" maintenance, i. e.
Current loading capacity ≤ 150 mA, short-circuit protected
while the system is under power. The termi-
Switching point
nals are coded to prevent incorrect connec-
0 (unattenuated) ≤ 2 mA
tions.
1 (attenuated) ≥ 4 mA
If a master/gateway other than the one in the

Control cabinet
Output cabinet housing is used, the connection to

I/O Modules
Number/Type 4 relay outputs the AS-Interface cable is established via the
Electrical isolation AS-Interface - Outputs: Safe isolation according to EN 50178 same terminals. Once the AS-Interface cable
(250 V AC)
Output - Output: Safe isolation according to EN 50178 (250 V has been connected to the terminals, the AS-
AC) Interface signal is automatically transferred
Contact loading 2 A/30 V DC per output to the Power Rail.
2 A/250 V AC per output Power to the module is supplied by the AS-

Field application
Lifetime mechanical: 30 x 106 switching cycles Interface cable and the outputs are powered

I/O Modules
electrical: externally (see connection diagram). A pro-
1 x 106 operations (30 V DC, 2 A, ohmic)
5 x 106 operations (250 V AC, 2 A, cosϕ = 1) gramming jack is available for address con-
4.5 x 106 switching cycles(250 V AC, 2 A, cosϕ = 0.7) figuration.
Programming instructions
Profile S-7.F Note:

Analogue modules
IO code 7 The outputs are de-energised by means of
ID code F an integrated watchdog, whenever communi-
Data bits (function via AS-Interface) input output cation on the AS-Interface cable is inter-
D0 IN1 OUT1 rupted for more than 80 ms. The watchdog
D1 IN2 OUT2 can be disabled by the parameter bit P0.
D2 IN3 OUT3
D3 IN4 OUT4 Accessories

Other modules
Parameter bits (programmable via AS-i) function
P0 communication monitoring VBP-HH1
P0 = 1 (basic setting), monitoring = ON, i.e. if communication Hand-held programming device
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs VAZ-PK-1,5M-V1-G
maintain their condition
Connection cable module/hand-held pro-
P1 not used
P2 not used
gramming device

Inductive sensors
P3 not used UPR-05
Ambient conditions Universal Power Rail with DIN rail and
Ambient temperature -25 ... 70 °C (248 ... 343 K) cover, 5 leads
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications UPR-E
Protection degree IP20 according to EN 60529 End cap for UPR-03 und UPR-05
Connection removable coded terminals, Power Rail
Photoelectric

Mass 170 g
sensors

Mounting DIN rail


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 123
VAA-4EA-KF2-ZE/T

AS-Interface sensor-/actuator module VAA-4EA-KF2-ZE/T


Dimensions
Masters and
Gateways

40 114
Terminal for wall mounting
Extender, Repeaters
Power Supplies,

111
118
93
Safety at work
Control cabinet

Electrical connection
I/O Modules

7
13
Field application

19 IN+
I/O Modules

2 AS-Interface -
25
Order code 1 AS-Interface + 8 IN1
14
VAA-4EA-KF2-ZE/T IN2
20 IN3
Cabinet module
26 IN4
4 inputs (PNP) and 4 electronic outputs
Analogue modules

9 for 3-wire
15
21 IN- sensors
27

11
Features 12 OUT1
ADDR
• Housing with removable, coded 17
terminals 18 OUT2
5

Power 23
• AS-Interface connection via Power
Other modules

4
24 OUT3
Rail
Rail 3
29
• Communication monitoring, turn-off PWR/ 30 OUT4
FAULT 6
• 115/230 V AC electronic outputs 5
AUX(N) Connection
AUX(L) for UAUX
• Inputs for 2- and 3-wire sensors
Inductive sensors

• Addressing jack
• Power supply of outputs from the
external auxiliary voltage
Indicating/operating means
• Power supply of inputs from the
module
• Function display for bus, inputs and 1 2 3 4 5 6
Photoelectric

outputs 7 8 9 10 11 12
sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IN1 IN2 OUT1 OUT2


Rotary encoders

IN3 IN4 PWR/ OUT3 OUT4


FAULT
13 14 15 16 17 18
19 20 21 22 23 24
Accessories

25 26 27 28 29 30

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
124 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-KF2-ZE/T
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-KF2-ZE/T AS-Interface cou-
Slave type Standard slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 4 electronic outputs for
LED PWR/FAULT dual LED green/red 115/230 V AC. To install the VAA-4EA-KF2-
green: AS-Interface voltage
red: communication error or address 0
ZE/T, simply snap it onto the 35 mm DIN
Rail, according to EN 50022, with the inte-

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state (input); 4 LED yellow grated Power Rail.
LED OUT switching state (output); 4 LED yellow When an AS-Interface master/gateway is
Electrical specifications used in the cabinet housing, the AS-Interface
Auxiliary voltage (output) UAUX 115 / 230 V AC ± 10 %
signal is automatically transmitted via the
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Power Rail. The connection of the module to
Rated operational current Ie ≤ 80 mA (without sensors) / max. 230 mA
the AS-Interface cable is accomplished by
simply snapping it onto the DIN Rail.
Input

Safety at work
The plug-in coded terminals of the inputs and
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
outputs allow "online" maintenance, i. e.
Supply from AS-Interface
while the system is under power. The termi-
Voltage 21 ... 31 V DC
nals are coded to prevent incorrect connec-
Current loading capacity ≤ 150 mA, short-circuit protected
tions at the inputs and outputs.
Switching point
If a master/gateway other than the one in the
0 (unattenuated) ≤ 2 mA
cabinet housing is used, the connection to
≥ 4 mA

Control cabinet
1 (attenuated)
the AS-Interface cable is established via the

I/O Modules
Output same terminals. Once the AS-Interface cable
Number/Type 4 electronic outputs, AC has been connected to the terminals, the AS-
Supply from external auxiliary voltage UAUX Interface signal is automatically transferred
Current ≤ 2 A total (TB ≤ 50°C) to the Power Rail.
≤ 1.5 A total (TB ≤ 60°C)
≤ 0.7 A total (TB ≤ 70°C) Power to the module and to the inputs is sup-
≥ (UAUX - 2 V) plied by the AS-Interface cable and the out-

Field application
Voltage
puts are powered externally (see connection

I/O Modules
Electrical isolation AS-Interface/Outputs: Safe isolation according to EN 50178
(250 V AC) diagram). A programming jack is available for
Programming instructions address configuration.
Profile S-7.F
IO code 7 Note:
ID code F The outputs are de-energised by means of

Analogue modules
Data bits (function via AS-Interface) input output an integrated watchdog, whenever communi-
D0 IN1 OUT1 cation on the AS-Interface cable is inter-
D1 IN2 OUT2 rupted for more than 80 ms. The watchdog
D2 IN3 OUT3 can be disabled by the parameter bit P0.
D3 IN4 OUT4 If a short circuit occurs in the sensor supply,
Parameter bits (programmable via AS-i) function the AS-Interface master indicates an error
P0 communication monitoring and the module disconnects from the AS-
P0 = 1 (basic setting), monitoring = ON, i.e. if communication Interface.

Other modules
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs
maintain their condition Accessories
P1 not used
VBP-HH1
P2 not used
P3 not used Hand-held programming device
Ambient conditions

Inductive sensors
VAZ-PK-1,5M-V1-G
Ambient temperature -25 ... 70 °C (248 ... 343 K) Connection cable module/hand-held pro-
Storage temperature -25 ... 85 °C (248 ... 358 K)
gramming device
Mechanical specifications
Protection degree IP20 according to EN 60529 UPR-05
Connection removable coded terminals, Power Rail Universal Power Rail with DIN rail and
Mass 170 g cover, 5 leads
Mounting DIN rail
Photoelectric

UPR-E
sensors

End cap for UPR-03 und UPR-05


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 125
VAA-4E-KF2-ZE

AS-Interface sensor module VAA-4E-KF2-ZE


Dimensions
Masters and
Gateways

20 114
Terminal for wall mounting
Extender, Repeaters
Power Supplies,

111
118
93
Safety at work
Control cabinet

Electrical connection
I/O Modules

4
Field application
I/O Modules

7
2 AS-Interface -
Order code 1 AS-Interface +
10 IN+

13
VAA-4E-KF2-ZE
Cabinet module +IN1
5
4 inputs (PNP)
Analogue modules

8 +IN2

Features 11 +IN3
ADDR
• Housing with removable, coded +IN4
14
terminals 5
6
• AS-Interface connection via Power
Other modules

Power 4
9
Rail Rail
3 12
IN- for 3-wire
• Addressing jack PWR/ sensors
15
FAULT
• Inputs for 2- and 3-wire sensors
• Function display for bus and inputs
Inductive sensors

• Power supply of inputs from the


module

Indicating/operating means

1 2 3
Photoelectric

4 5 6
sensors

ADDR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IN1 IN2
Rotary encoders

IN3 IN4 PWR/


FAULT
7 8 9
10 11 12
Accessories

13 14 15

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
126 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VAA-4E-KF2-ZE
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E-KF2-ZE AS-Interface coupling
Slave type Standard slave
module is a cabinet module with 4 inputs. Its
Indicators/operating means design, only 20 mm wide, occupies little
LED PWR/FAULT dual LED green/red space in a cabinet installation. The VAA-4E-
green: AS-Interface voltage
red: communication error or address 0
KF2-ZE is installed by snapping it onto the
35 mm DIN Rail per EN 50022, with the inte-

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state (input); 4 LED yellow grated Power Rail.
LED OUT switching state (output); 4 LED yellow When an AS-Interface master/gateway is
Electrical specifications used in the cabinet housing, the AS-Interface
Protection class III
signal is automatically transmitted via the
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Power Rail. The connection of the module to
Rated operational current Ie ≤ 50 mA (without sensors) / max. 200 mA
the AS-Interface cable is accomplished by
simply snapping it onto the DIN Rail.
Input

Safety at work
The plug-in coded terminals of the inputs
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
allow "online" maintenance, i. e. while the
Supply from AS-Interface
system is under power. The terminals are
Voltage 21 ... 31 V DC
coded to prevent incorrect connections.
Current loading capacity ≤ 150 mA, short-circuit protected
If a master/gateway other than the one in the
Switching point
cabinet housing is used, the connection to
0 (unattenuated) ≤ 2 mA
the AS-Interface cable is established via the
≥ 4 mA

Control cabinet
1 (attenuated)
same terminals. Once the AS-Interface cable

I/O Modules
Programming instructions has been connected to the terminals, the AS-
Profile S-0.0 Interface signal is automatically transferred
IO code 0 to the Power Rail.
ID code 0 The module and the inputs are supplied by
Data bits (function via AS-Interface) input output the AS-Interface cable (see connection dia-
D0 IN1 - gram). A programming jack is available for

Field application
D1 IN2 - address configuration.

I/O Modules
D2 IN3 - Note:
D3 IN4 - If an overload occurs in the sensor power
Parameter bits (programmable via AS-i) function supply, the AS-Interface master indicates an
P0 not used error and the module disconnects from the
P1 not used AS-Interface.

Analogue modules
P2 not used
P3 not used
Ambient conditions Accessories
Ambient temperature -25 ... 70 °C (248 ... 343 K) VBP-HH1
Storage temperature -25 ... 85 °C (248 ... 358 K) Hand-held programming device
Mechanical specifications
Protection degree IP20 according to EN 60529 VAZ-PK-1,5M-V1-G
Connection removable coded terminals, Power Rail Connection cable module/hand-held pro-

Other modules
Mass 90 g gramming device
Mounting DIN rail
UPR-05
Universal Power Rail with DIN rail and
cover, 5 leads
UPR-E

Inductive sensors
End cap for UPR-03 und UPR-05

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 127
VBA-4E3A-KE-ZE/E2

AS-Interface sensor-/actuator module VBA-4E3A-KE-ZE/E2


Dimensions
Masters and
Gateways

22.5 7 99
Extender, Repeaters
Power Supplies,

102
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

Switch position
"INT" "EXT"

4 inputs IN1 ... IN4


Field application

AS-Interface - UEXT
I+
I/O Modules

AS-Interface + IN
Order code IN
VBA-4E3A-KE-ZE/E2 EXT

KE switch cabinet module I-


INT
4 inputs and 3 outputs for 3-wire for 3-wire
Analogue modules

ADDR sensors sensors

Features
• A/B slave with extended addressing
PWR
possibility for up to 62 slaves
OUT 3 outputs O1 ... O3
FAULT
• Housing with removable and colour
Other modules

O
coded terminals
AUX
• Communication monitoring Load
AUX +
• Inputs for 2- and 3-wire sensors AUX -
O-
• Addressing jack
Inductive sensors

• Power supply of outputs from the


external auxiliary voltage
• Supply of inputs external or from the
module, as required Indicating/operating means
• Function display for bus, ext. auxiliary
I- 1 I- 2 I- 3 I- 4 Beschriftungsfeld
voltage, inputs and outputs IN1 IN2 IN3 IN4 label field
Photoelectric

1 Entriegeln / unlock
Auf BEIDEN Seiten drücken / I+ 1 I+ 2 I+ 3 I+ 4
sensors

press on BOTH sides


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

2 Öffnen / open 1 2 3 4
Oberteil bis zum STOPP IN
herausziehen /
pull upper part until STOP FAULT INT
Rotary encoders

PWR AUX
EXT
ADDR

INT 1 2 3
OUT
3 Schalter einstellen / set switch
INT=Sensorversorgung aus AS-i /
sensor supply from AS-i
EXT=Sensorversorgung extern /
external sensor supply
Accessories

01 0-1 02 0-2
INT/EXT Umschaltung nur spannungslos 03 0-3
INT/EXT Switchable under off-circuit conditions only AS-i+ AS-i- AUX+ AUX-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
128 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-4E3A-KE-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E3A-KE-ZE/E2 AS-Interface cou-
Slave type A/B slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 3 electronic outputs. The only
LED FAULT Fault display; Red LED 22.5 mm width housing requires not much
red: Communication fault or address is 0
red, flashing: Overload, internal input supply or outputs
space in the switch cabinet. The VBA-4E3A-
KE-ZE/E2 is installed by snapping on the

Extender, Repeaters
LED INT Internal input voltage active; LED green

Power Supplies,
LED PWR AS-Interface voltage; LED green
35 mm DIN Rail in accordance with
LED AUX ext. auxiliary voltage UAUX; LED green
EN 50022.
LED IN switching state (input); 4 LED yellow
The connection type is made through plug-in
LED OUT switching state (output); 3 LED yellow
terminals. 4-way terminal blocks (black) are
used for the inputs. The connection of the
Electrical specifications
outputs and the external auxiliary supply and
Auxiliary voltage (input) UEXT 12 ... 30 V DC PELV
AS-Interface is made through the 2-way ter-
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV

Safety at work
minal blocks (outputs black, Auxiliary voltage
Protection class III
gray and AS-Interface yellow). This allows
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
simple disconnection of single actuators or
Rated operational current Ie ≤ 35 mA (without sensors) / max. 190 mA
supply for commissioning or service.
Overvoltage protection UEXT, UAUX, Ue: Over voltage category III, safe isolated power
supplies (PELV)
The power supply of the inputs and the con-
nected sensors can made as required inter-
Input
nal via the module (AS-Interface) or via an

Control cabinet
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
external voltage source. The switching

I/O Modules
Supply from AS-Interface (switch position INT, basic setting) or exter-
nal UEXT (switch position EXT)
occurs with the switch in the device. The
Voltage 21 ... 31 V DC (INT)
selection of the internal input supply is indi-
Current loading capacity ≤ 150 mA, overload- and short-circuit proof (INT)
cated via the LED INT. The current switching
Input current ≤ 8 mA (limited internally)
state of each in- and output is indicated by a
Switching point according to DIN EN 61131-2 (Type 2)
LED on the front plate.
≤ 2 mA

Field application
0 (unattenuated)
Note:

I/O Modules
1 (attenuated) ≥ 4 mA
Signal delay < 2 ms (input/AS-Interface)
The device is equipped with a watchdog,
Signal frequency ≤ 250 Hz
which switches the outputs to their de-ener-
gized state, when on the AS-interface cable
Output
is no communication for more than 40 ms.
Number/Type 3 electronic outputs, PNP, overload and short-circuit proof
An overloading of the internal input supply or
Supply from external auxiliary voltage UAUX

Analogue modules
of the outputs will be reported via the func-
Current O1 max. 3 A, O2/O3 max. 1.5 A, total 6 A (TB ≤ 40 °C)
O1 max. 2 A, O2/O3 max. 1 A, total 4 A (TB ≤ 60 °C) tion 'peripheral error' to the AS-Interface
Voltage ≥ (UAUX - 0,5 V) master. Communication via the AS-Interface
Usage category DC-13 remains intact.
Programming instructions
Profile S-7.A.0 Accessories
IO code 7
VBP-HH1

Other modules
ID code A
ID1 code 7 Hand-held programming device
ID2 code 0
VAZ-PK-1,5M-V1-G
Data bits (function via AS-Interface) input output
Connection cable module/hand-held pro-
D0 IN1 O1
D1 IN2 O2
gramming device
D2 IN3 O3

Inductive sensors
D3 IN4 -
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used
P3 not used
Ambient conditions
Photoelectric

Ambient temperature -25 ... 60 °C (248 ... 333 K)


sensors

Storage temperature -25 ... 85 °C (248 ... 358 K)


Relative humidity 90 % , not condensed
Degree of soiling 2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Mechanical specifications
Protection degree IP20 according to EN 60529
Rotary encoders

Connection removable terminals


rated connection capacity:
rigid/flexible (with and without wire-end ferrules):
0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-sec-
tion:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Mass 150 g
Mounting DIN rail
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 129
VBA-4E3A-KE-ZE/R

AS-Interface sensor-/actuator module VBA-4E3A-KE-ZE/R


Dimensions
Masters and
Gateways

22.5 7 99
Extender, Repeaters
Power Supplies,

102
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

Switch position
"INT" "EXT"

4 Inputs IN1 ... IN4


Field application

AS-Interface - UEXT
I+
I/O Modules

AS-Interface + IN
Order code IN
VBA-4E3A-KE-ZE/R EXT

KE switch cabinet module I-


INT
4 inputs (PNP) and 3 relay outputs for 3-wire for 3-wire
Analogue modules

ADDR sensors sensors

Features
• A/B slave with extended addressing
possibility for up to 62 slaves
• Housing with removable terminals 3 Outputs O1 ... O3
Other modules

OUT
O1.4 ... O3.4
• Communication monitoring PWR
O1.1 ... O3.1
• Inputs for 2- and 3-wire sensors
FAULT
• Isolated relay output
• Addressing jack
Inductive sensors

• Supply of inputs external or from the


module, as required
• Function display for bus, internal Indicating/operating means
input supply, inputs and outputs

I- 1 I- 2 I- 3 I- 4 Beschriftungsfeld /
Vor dem Öffnen alle Anschlüsse IN1 IN2 IN3 IN4 label field
Photoelectric

spannungsfrei schalten / I+ 1 I+ 2 I+ 4
I+ 3
de-energize all connections
sensors

before opening
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 2 3 4
1 Entriegeln / unlock
Auf BEIDEN Seiten drücken / IN
press on BOTH sides FAULT INT
Rotary encoders

2 Öffnen / open
Oberteil bis zum STOPP
PWR
herausziehen / ADDR
pull upper part until STOP
1 2 3
EXT INT OUT

3 Schalter einstellen / set switch


INT=Sensorversorgung aus AS-i /
sensor supply from AS-i
Accessories

01.1 01.4
EXT=Sensorversorgung extern / 02.1 02.4 03.1 03.4
external sensor supply
AS-i+ AS-i-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
130 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-4E3A-KE-ZE/R
Technical data Function

Masters and
General specifications

Gateways
The AS-Interface VBA-4E3A-KE-ZE/R I/O
Slave type A/B slave
module is a switch cabinet module with
Indicators/operating means 4 inputs and 3 relay outputs. The housing,
LED FAULT Fault display; Red LED only 22.5 mm in width, takes up little place in
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
the switch cabinet. The VBA-4E3A-KE-ZE/R
can be mounted by snapping it onto the

Extender, Repeaters
LED INT Internal input voltage active; LED green

Power Supplies,
LED PWR AS-Interface voltage; LED green
35 mm carrier rail in accordance with
LED IN switching state (input); 4 LED yellow
EN 50022.
LED OUT switching state (output); 3 LED yellow
Plug-in terminals are used for connection. 4X
terminal blocks (black) are used for the
Electrical specifications
inputs. Double terminal blocks (red outputs,
Auxiliary voltage (input) UEXT 12 ... 30 V DC PELV
yellow AS-Interface) are used to connect out-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
puts and the AS-Interface. This makes it pos-
Rated operational current Ie ≤ 35 mA (without sensors) / max. 190 mA

Safety at work
sible to separate individual actuators or to
Overvoltage protection O1 ... O3: Over voltage category II
UEXT, Ue: Over voltage category III, safe isolated power sup-
supply power during commissioning or serv-
plies (PELV) icing.
Input Either the module (from the AS-Interface) or
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
an external power source are used to supply
Supply from AS-Interface (switch position INT, basic setting) or exter-
power to the inputs and the connected sen-
nal UEXT (switch position EXT) sors. One switch in the device is used for

Control cabinet
switching. The selection of the internal input

I/O Modules
Voltage 21 ... 31 V DC (INT)
Current loading capacity ≤ 150 mA, overload- and short-circuit proof (INT) power supply is displayed on the INT LED.
Input current ≤ 8 mA (limited internally) An LED on the front control plate is used to
Switching point according to DIN EN 61131-2 (Type 2) display the current switching state for each
0 (unattenuated) ≤ 2 mA input and output.
1 (attenuated) ≥ 4 mA
Signal delay < 2 ms (input/AS-Interface) Note:

Field application
The device is equipped with communication

I/O Modules
Signal frequency ≤ 250 Hz
Output monitoring that turns off the outputs if no AS-
Number/Type 3 relay outputs, normally open Interface communication has taken place
Supply none with the device for more than 40 ms.
Nominal load An overload of the internal input supply is
Per contact 2 A / 30 V DC; 2 A / 253 V AC reported by the 'periphery error' to the AS-

Analogue modules
Per module 6A Interface master. Communication over the
Minimum load AS-Interface remains in effect.
Per contact 10 mA / 5 V DC
Short-circuit proof Contact: 500 A / 40 ms Accessories
Switching off power 500 VA
Switching delay < 10 ms (AS-Interface/contact) VBP-HH1
Usage category DC-13 and AC-14 Hand-held programming device

Other modules
Switching frequency f < 20 Hz (without load)
< 0.1 Hz (nominal load) VAZ-PK-1,5M-V1-G
Switchings Connection cable module/hand-held pro-
Mechanical 30 x 106 gramming device
Electrical 1 x 106 (40 V DC, 2 A, ohmic)
0.5 x 106 (253 V AC, 2 A, cosϕ = 1)
0.45 x 106 (253 V AC, 2 A, cosϕ = 0.7)

Inductive sensors
Electrical isolation
Input/Output IN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1,
rated insulation voltage 278 V AC
Input/AS-Interface none
Output/Output O1 to O2, O3: safe isolation according to EN 60947-1,
rated insulation voltage 278 V AC
O2 to O3: basic insulation according to EN 60947-1,
rated insulation voltage 278 V AC
Output/AS-Interface safe isolation acc. to EN 60947-1,
Photoelectric

rated insulation voltage 278 V AC


sensors

Programming instructions
Profile S-7.A.0
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IO code 7
ID code A
ID1 code 7
Rotary encoders

ID2 code 0
Data bits (function via AS-Interface) input output
D0 IN1 O1
D1 IN2 O2
D2 IN3 O3
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
Accessories

P2 not used
P3 not used

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 131
AS-Interface sensor-/actuator module VBA-4E3A-KE-ZE/R
Standard conformity
Standards EN 50295:1999-10
Masters and
Gateways

EN 61326:2002-03
NAMUR NE 21: 1998-08
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Relative humidity 90 % , not condensed
Extender, Repeaters
Power Supplies,

Degree of soiling 2
Mechanical specifications
Protection degree IP20 according to EN 60529
Connection removable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules):
0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-sec-
Safety at work

tion:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Mass 170 g
Mounting DIN rail

Notes
Installation, commissioning, maintenance:
Control cabinet
I/O Modules

The device has to be installed into a separate electrical operation facility with access only for
electrical professionals or instructed persons.
The plug connectors must not be connected or disconnected under power.
The operator is responsible for complying with rights, guidelines and standards according to
the intended or planned use.
Field application

Bundled devices:
I/O Modules

Isolation to external surfaces: basic isolation according to EN 60947-1, no basic isolation to


terminals.
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
132 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
133
Notes

Accessories Rotary encoders Photoelectric Inductive sensors Other modules Analogue modules I/O Modules I/O Modules Safety at work Power Supplies, Masters and
sensors Field application Control cabinet Extender, Repeaters Gateways
VBA-4E-KE-ZE

AS-Interface sensor module VBA-4E-KE-ZE


Dimensions
Masters and
Gateways

22.5 7 99
Extender, Repeaters
Power Supplies,

102
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

Switch position
"INT" "EXT"

4 Inputs IN1 ... IN4


Field application

AS-Interface - UEXT
I+
I/O Modules

AS-Interface + IN
Order code IN
VBA-4E-KE-ZE EXT

KE switch cabinet module I-


INT
4 inputs (PNP) for 3-wire for 3-wire
Analogue modules

ADDR sensors sensors

Features
• A/B slave with extended addressing
possibility for up to 62 slaves
• Housing with removable and colour
Other modules

coded terminals
PWR
• Communication monitoring
FAULT
• Inputs for 2- and 3-wire sensors
• Addressing jack
Inductive sensors

• Supply of inputs external or from the


module, as required
• Function display for bus, internal
input supply and inputs Indicating/operating means

I 1 I 2 I 3 I 4 Beschriftungsfeld /
1 Entriegeln / unlock IN1 IN2 IN3 IN4 label field
Photoelectric

Auf BEIDEN Seiten drücken / I+ 1 I+ 2 I + 3 I+ 4


sensors

press on BOTH sides

1 2 3 4
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

2 Öffnen / open
Oberteil bis zum STOPP
herausziehen /
IN
pull upper part until STOP FAULT INT
Rotary encoders

EXT
PWR
ADDR
INT

3 Schalter einstellen / set switch


INT=Sensorversorgung aus AS-i / PEPPERL+FUCHS
sensor supply from AS-i
EXT=Sensorversorgung extern /
external sensor supply
Accessories

INT/EXT Umschaltung nur spannungslos


INT/EXT Switchable under off-circuit conditions only AS-i + AS-i

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
134 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VBA-4E-KE-ZE
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E-KE-ZE AS-Interface coupling
Slave type A/B slave
module is a cabinet module with 4 inputs.
Indicators/operating means The housing, only 22.5 mm in width, takes up
LED FAULT Fault display; Red LED little place in the switch cabinet. The module
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
is mounted by snapping onto the 35 mm DIN
rail in accordance with EN 50022.

Extender, Repeaters
LED INT Internal input voltage active; LED green

Power Supplies,
LED PWR AS-Interface voltage; LED green
It can be connected by plug-in terminals. 4-
LED IN switching state (input); 4 LED yellow
way terminal blocks (black) are used for the
inputs. The AS-Interface is connected via a
Electrical specifications
double terminal block (yellow). This allows
Auxiliary voltage (input) UEXT 12 ... 30 V DC PELV
simple disconnection of single actuators or
Protection class III
supply by commissioning or service.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Either the module (from the AS-Interface) or
Rated operational current Ie ≤ 30 mA (without sensors) / max. 180 mA

Safety at work
an external power source are used to supply
Overvoltage protection UEXT, Ue: Over voltage category III, safe isolated power sup-
plies (PELV)
power to the inputs and the connected sen-
sors. One switch in the device is used for
Input
switching. The selection of the internal input
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
power supply is displayed on the INT LED.
Supply from AS-Interface (switch position INT, basic setting) or exter-
nal UEXT (switch position EXT)
An LED on the front control plate is used to
Voltage 21 ... 31 V DC (INT)
display the current switching state for each

Control cabinet
input.

I/O Modules
Current loading capacity ≤ 150 mA, overload- and short-circuit proof (INT)
Input current ≤ 8 mA (limited internally)
Switching point according to DIN EN 61131-2 (Type 2)
Note:
0 (unattenuated) ≤ 2 mA
An overload of the internal input supply is
1 (attenuated) ≥ 4 mA
reported by the 'periphery error' to the AS-
Signal delay < 2 ms (input/AS-Interface)
Interface master. Communication over the
≤ 250 Hz
AS-Interface remains in effect.

Field application
Signal frequency

I/O Modules
Programming instructions
Profile S-0.A.0 Accessories
IO code 0
VBP-HH1
ID code A
ID1 code 7
Hand-held programming device
ID2 code 0

Analogue modules
VAZ-PK-1,5M-V1-G
Data bits (function via AS-Interface) Input
Connection cable module/hand-held pro-
D0 IN1
gramming device
D1 IN2
D2 IN3
D3 IN4
Parameter bits (programmable via AS-i) function
P0 not used

Other modules
P1 not used
P2 not used
P3 not used
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)

Inductive sensors
Relative humidity 90 % , not condensed
Degree of soiling 2
Mechanical specifications
Protection degree IP20 according to EN 60529
Connection removable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules):
0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-sec-
Photoelectric

tion:
sensors

flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Mass 150 g
Mounting DIN rail
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 135
VAA-4E4A-KE-ZE/E2

AS-Interface sensor-/actuator module VAA-4E4A-KE-ZE/E2


Dimensions
Masters and
Gateways

22.5 7 99
Extender, Repeaters
Power Supplies,

102
Safety at work
Control cabinet

Electrical connection
I/O Modules

Switch position
"INT" "EXT"

EXT
4 inputs IN1 ... IN4
Field application

I+ UEXT
I/O Modules

AS-Interface - INT IN
Order code AS-Interface + IN
VAA-4E4A-KE-ZE/E2 EXT

KE switch cabinet module I-


INT
4 inputs and 4 outputs for 3-wire for 3-wire
Analogue modules

sensors sensors
ADDR

Features
• Housing with removable, mechanical PWR
and colour coded terminals
OUT 4 outputs O1 ... O4
FAULT
• Communication monitoring
Other modules

O
• Inputs for 2- and 3-wire sensors
AUX
• Addressing jack Load
AUX +

• Power supply of outputs from the AUX -


O-
external auxiliary voltage
Inductive sensors

• Selectable supply to the sensors:


External or from the module
• Function display for bus, external
auxiliary voltage, internal sensor Indicating/operating means
supply, inputs and outputs
I- 1 I- 2 I- 3 I- 4
IN1 IN2 IN3 IN4 label field
Photoelectric

I+ 1 I+ 2 I+ 3 I+ 4
sensors

ATT E NT I O N
Do not connect the terminals I+, IN and I- with
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

any external potential when switch set to "INT" 1 2 3 4


IN
Sensor supply: FAULT INT
Rotary encoders

INT = internal sensor supply (from AS-i)


EXT = external sensor supply PWR AUX
INT ADDR

1 2 3 4
EXT OUT
Accessories

O1 O-1 O2 O-2
O3 O-3 O4 O-4
AS-i+ AS-i- AUX+ AUX-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
136 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4E4A-KE-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E4A-KE-ZE/E2 AS-Interface I/O
Slave type Standard slave
module is a cabinet module with 4 inputs and
Indicators/operating means 4 electronic outputs. The only 22.5 mm width
LED FAULT Fault display; Red LED housing requires not much space in the
red: Communication fault or address is 0
red, flashing: Overload, internal input supply or outputs
switch cabinet. The module is installed by
snapping on the 35 mm DIN Rail in accord-

Extender, Repeaters
LED INT Internal input voltage active; LED green

Power Supplies,
LED PWR AS-Interface voltage; LED green
ance with EN 50022.
LED AUX ext. auxiliary voltage UAUX; dual LED green/red
The connection is made through plug-in ter-
green: voltage OK minals. For the inputs and outputs 4-way ter-
red: reverse voltage minal blocks (black) are used. The
LED IN switching state (input); 4 LED yellow connection of the external auxiliary supply
LED OUT switching state (output); 4 LED yellow and AS-Interface is made through the 2-way-
Electrical specifications terminal blocks (auxiliary supply gray, AS-

Safety at work
Auxiliary voltage (input) UEXT 12 ... 30 V DC PELV Interface yellow). In order to avoid
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV exchanges, the terminals for inputs and out-
Protection class III puts are coded mechanically.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface The power supply of the inputs and the con-
Rated operational current Ie ≤ 35 mA (without sensors) / max. 190 mA nected sensors can be made as required via
Overvoltage protection UEXT, UAUX, Ue: Over voltage category III, safe isolated power the internal supply of the module (AS-Inter-
supplies (PELV) face) or via an external voltage source. The

Control cabinet
switching is carried out by means of a switch

I/O Modules
Input
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC that is positioned at the side of the module.
Supply from AS-Interface (switch position INT, basic setting) or exter- The selection of the internal input supply is
nal UEXT (switch position EXT) indicated via the LED INT. The current
Voltage 21 ... 31 V DC (INT) switching state of each input and output is
Current loading capacity ≤ 150 mA, overload- and short-circuit proof (INT) indicated by the resp. LED IN and OUT.
Input current ≤ 8 mA (limited internally)

Field application
Note:

I/O Modules
Switching point according to DIN EN 61131-2 (Type 2)
0 (unattenuated) ≤ 2 mA The device is equipped with a communica-
1 (attenuated) ≥ 4 mA tion monitoring, which switches the outputs
Signal delay < 2 ms (input/AS-Interface) to their de-energized state, when there is no
Signal frequency ≤ 250 Hz AS-Interface communication with the module
Output for more than 40 ms.

Analogue modules
Number/Type 4 electronic outputs, PNP, overload and short-circuit proof An overloading of the internal input supply or
Supply from external auxiliary voltage UAUX of the outputs will be reported via the func-
Current O1 ... O4 max. 0.7 A, Sum 2.8 A tion 'peripheral error' to the AS-Interface
Voltage ≥ (UAUX - 0,5 V) master. The communication via the AS-Inter-
Usage category DC-13 face remains intact.
Programming instructions
Profile S-7.0 Accessories

Other modules
IO code 7
ID code 0 VBP-HH1
ID1 code F Hand-held programming device
ID2 code E
Data bits (function via AS-Interface) input output
VAZ-PK-1,5M-V1-G
D0 IN1 O1 Connection cable module/hand-held pro-
D1 IN2 O2 gramming device

Inductive sensors
D2 IN3 O3
D3 IN4 O4
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used
P3 not used
Photoelectric

Ambient conditions
sensors

Ambient temperature -25 ... 60 °C (248 ... 333 K)


Storage temperature -25 ... 85 °C (248 ... 358 K)
Relative humidity 90 % , not condensed
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Degree of soiling 2
Mechanical specifications
Rotary encoders

Protection degree IP20 according to EN 60529


Connection removable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules):
0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-sec-
tion:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Mass 150 g
Accessories

Mounting DIN rail

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 137
VAA-4E4A-KE-ZE/R

AS-Interface sensor-/actuator module VAA-4E4A-KE-ZE/R


Dimensions
Masters and
Gateways

22.5 7 99
Extender, Repeaters
Power Supplies,

102
Safety at work
Control cabinet

Electrical connection
I/O Modules

Switch position
"INT" "EXT"

EXT
4 Inputs IN1 ... IN4
Field application

AS-Interface - UEXT
I+
I/O Modules

AS-Interface + INT IN
Order code IN
VAA-4E4A-KE-ZE/R EXT

KE switch cabinet module I-


INT
4 inputs (PNP) and 4 relay outputs for 3-wire for 3-wire
Analogue modules

ADDR sensors sensors

Features
• Housing with removable, mechanical
and colour coded terminals
• Communication monitoring 4 Outputs O1 ... O4
Other modules

OUT
O1.4 ... O4.4
• Inputs for 2- and 3-wire sensors PWR
O1.1 ... O4.1
• Isolated relay output FAULT

• Addressing jack
• Selectable supply to the sensors:
Inductive sensors

External or from the module


• Function display for bus, internal
sensor supply, inputs and outputs
Indicating/operating means

The plug connectors with dangerous contact I- 1 I- 2 I- 3 I- 4


voltage must not be connected or disconnected IN1 IN2 IN3 IN4 label field
Photoelectric

I+ 1 I+ 2 I+ 3 I+ 4
under power
sensors

ATT E NT I O N
Do not connect the terminals I+, IN and I- with
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

any external potential when switch set to "INT" 1 2 3 4


IN
Sensor supply: FAULT INT
Rotary encoders

INT = internal sensor supply (from AS-i)


EXT = external sensor supply PWR
ADDR
INT

1 2 3 4
EXT
OUT
Accessories

O1.1 O1.4 O2.1 O2.4


O3.1 O3.4 O4.1 O4.4
AS-i+ AS-i-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
138 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4E4A-KE-ZE/R
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E4A-KE-ZE/R AS-Interface I/O
Slave type Standard slave
module is a cabinet module with 4 inputs and
Indicators/operating means 4 relay outputs. The only 22.5 mm width
LED FAULT Fault display; Red LED housing requires not much space in the
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
switch cabinet. The module is installed by
snapping on the 35 mm DIN Rail in accord-

Extender, Repeaters
LED INT Internal input voltage active; LED green

Power Supplies,
LED PWR AS-Interface voltage; LED green
ance with EN 50022.
LED IN switching state (input); 4 LED yellow
The connection is made through plug-in ter-
LED OUT switching state (output); 4 LED yellow
minals. For the inputs and outputs 4-way-ter-
minal blocks (inputs black, outputs red) are
Electrical specifications
used. The connection of the AS-Interface is
Auxiliary voltage (input) UEXT 12 ... 30 V DC PELV
made via a 2-way-terminal block (yellow). In
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
order to avoid exchanges, the terminals for
Rated operational current Ie ≤ 35 mA (without sensors) / max. 190 mA

Safety at work
inputs and outputs as well as AS-Interface
Overvoltage protection O1 ... O4: Over voltage category II
UEXT, Ue: Over voltage category III, safe isolated power sup-
are coded mechanically.
plies (PELV) The power supply of the inputs and the con-
Input nected sensors can be made as required via
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
the internal supply of the module (AS-Inter-
Supply from AS-Interface (switch position INT, basic setting) or exter-
face) or via an external voltage source. The
nal UEXT (switch position EXT) switching is carried out by means of a switch

Control cabinet
that is positioned at the side of the module.

I/O Modules
Voltage 21 ... 31 V DC (INT)
Current loading capacity ≤ 150 mA, overload- and short-circuit proof (INT) The selection of the internal input supply is
Input current ≤ 8 mA (limited internally) indicated via the LED INT. The current
Switching point according to DIN EN 61131-2 (Type 2) switching state of each input and output is
0 (unattenuated) ≤ 2 mA indicated by the resp. LED IN and OUT.
1 (attenuated) ≥ 4 mA
Signal delay < 2 ms (input/AS-Interface) Note:

Field application
The device is equipped with a communica-

I/O Modules
Signal frequency ≤ 250 Hz
Output tion monitoring, which switches the outputs
Number/Type 4 relay outputs, normally open to their de-energized state, when there is no
Supply none AS-Interface communication with the module
Nominal load for more than 40 ms.
Per contact 2 A / 30 V DC; 2 A / 253 V AC An overloading of the internal input supply

Analogue modules
Per module 8A will be reported via the function 'peripheral
Control circuit ≤ 8 mA per relay (from AS-Interface) error' to the AS-Interface master. The com-
Switching delay < 10 ms (AS-Interface/contact) munication via the AS-Interface remains
Usage category DC-13 and AC-14 intact.
Switchings
Mechanical 5 x 106 Accessories
Electrical 0.2 x 106 (250 V AC, 2 A, cosϕ = 0.4)
VBP-HH1

Other modules
Electrical isolation
Input/Output safe isolation, rated insulation voltage 300 V AC Hand-held programming device
Input/AS-Interface Switch position INT: None Switch position EXT: reinforced
insulation, rated insulation voltage 66 V DC
VAZ-PK-1,5M-V1-G
Output/Output basic insulation, rated insulation voltage 300 V AC Connection cable module/hand-held pro-
Output/AS-Interface safe isolation, rated insulation voltage 300 V AC gramming device
Programming instructions

Inductive sensors
Profile S-7.0
IO code 7
ID code 0
ID1 code F
ID2 code E
Data bits (function via AS-Interface) input output
D0 IN1 O1
Photoelectric

D1 IN2 O2
sensors

D2 IN3 O3
D3 IN4 O4
Parameter bits (programmable via AS-i) function
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P0 not used
P1 not used
P2 not used
Rotary encoders

P3 not used
Standard conformity
Electrical isolation EN 60947-1
Standards EN 50295:1999-10, EN 61326:2002-03
NAMUR NE 21: 1998-08
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Accessories

Storage temperature -25 ... 85 °C (248 ... 358 K)


Relative humidity 90 % , not condensed
Degree of soiling 2

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 139
AS-Interface sensor-/actuator module VAA-4E4A-KE-ZE/R
Mechanical specifications
Protection degree IP20 according to EN 60529
Masters and
Gateways

Connection removable terminals


rated connection capacity:
rigid/flexible (with and without wire-end ferrules):
0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-sec-
tion:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Extender, Repeaters
Power Supplies,

Mass 170 g
Mounting DIN rail

Notes
Installation, commissioning, maintenance:
The device has to be installed into a separate electrical operation facility with access only for
electrical professionals or instructed persons.
Safety at work

Connectors with dangerous contact voltage must only be plugged-in or unplugged in a de-
energized state.
The rights, guidelines and standards according to the intended or planned use should be
observed.

Bundled devices:
Control cabinet

Isolation to external surfaces: basic insulation to EN 60947-1, no basic insulation at the termi-
I/O Modules

nals.
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
140 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
141
Notes

Accessories Rotary encoders Photoelectric Inductive sensors Other modules Analogue modules I/O Modules I/O Modules Safety at work Power Supplies, Masters and
sensors Field application Control cabinet Extender, Repeaters Gateways
VBA-4E2A-KE1-Z/E2

AS-Interface sensor-/actuator module VBA-4E2A-KE1-Z/E2


Dimensions
Masters and
Gateways

50.5
22.5 48.5
Extender, Repeaters
Power Supplies,

99.6
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

4 inputs IN1 ... IN4


Field application
I/O Modules

AS-Interface - I+
Order code AS-Interface +
IN
IN
VBA-4E2A-KE1-Z/E2
KE1 switch cabinet module
4 inputs and 2 outputs
Analogue modules

ADDR

Features
• A/B slave with extended addressing
PWR
possibility for up to 62 slaves
OUT 2 outputs O1, O2
FAULT
• Housing with removable terminals
Other modules

O
• Communication monitoring
AUX
• Inputs for 2-wire sensors and Load
AUX +
mechanical contacts AUX -
O-
• Addressing jack
Inductive sensors

• Power supply of outputs from the


external auxiliary voltage
• Power supply of inputs from the
module Indicating/operating means
• Function display for bus, ext. auxiliary
voltage, inputs and outputs IN1 IN2 IN3 IN4
Photoelectric

I+ 1 I+ 2 I+3 I+ 4
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 2 3 4
IN
FAULT
Rotary encoders

PWR AUX
ADDR

1 2
OUT

01 0 1 02 0 2
Accessories

AS-i + AS-i AUX+ AUX

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
142 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-4E2A-KE1-Z/E2
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E2A-KE1-Z/E2 AS-interface cou-
Slave type A/B slave
pling module is a cabinet module with
Indicators/operating means 4 inputs and 2 electronic outputs. The hous-
LED FAULT error display; LED red ing, only 22.5 mm in width and 48.5 mm in
red: communication error or address is 0
red flashing: overload of outputs
height, takes up little place in the switch cabi-
net. The module is mounted by snapping

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green
onto the 35 mm DIN rail in accordance with
LED IN switching state (input); 4 LED yellow
EN 50022.
LED OUT switching state (output); 2 LED yellow
Plug-in terminals are used for connection. 4-
way terminal blocks (black) are used for the
Electrical specifications
inputs. The connection of the outputs and the
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
external auxiliary supply and AS-Interface is
Protection class III
made through the 2-way terminal blocks (out-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface

Safety at work
puts black, auxiliary voltage gray and AS-
Rated operational current Ie ≤ 25 mA (without sensors) / max. 60 mA
Interface yellow). This makes it possible to
Overvoltage protection UAUX, Ue: Over voltage category III, safe isolated power sup-
plies (PELV)
separate individual actuators or to supply
power during commissioning or servicing.
Input
The supply of the inputs and the connected
Number/Type 4 inputs for 2-wire sensors (PNP), DC or for mechanical con-
tacts
sensors occurs internally via the module
Input current ≤ 8 mA (limited internally)
(from AS-Interface). An LED on the front con-

Control cabinet
trol plate is used to display the current

I/O Modules
Switching point according to DIN EN 61131-2 (Type 2)
0 (unattenuated) ≤ 2 mA
switching state for each input and output.
1 (attenuated) ≥ 4 mA
Signal delay < 2 ms (input/AS-Interface)
Note:
Signal frequency ≤ 250 Hz
The device is equipped with a watchdog,
which switches the outputs to their de-ener-
Output
gized state, when on the AS-interface cable

Field application
Number/Type 2 electronic outputs, PNP, overload and short-circuit proof
is no communication for more than 40 ms.

I/O Modules
Supply from external auxiliary voltage UAUX
An overload of the outputs is reported by the
Current O1/O2 max. 1.5 A, total 3 A (TB ≤ 40 °C)
O1/O2 max. 1 A, total 2 A (TB ≤ 70 °C) 'periphery error' to the AS-Interface master.
Voltage ≥ (UAUX - 0,5 V) Communication over the AS-Interface
Usage category DC-13 remains in effect.
Programming instructions

Analogue modules
Profile S-7.A.0 Accessories
IO code 7
VBP-HH1
ID code A
ID1 code 7 Hand-held programming device
ID2 code 0
VAZ-PK-1,5M-V1-G
Data bits (function via AS-Interface) input output
Connection cable module/hand-held pro-
D0 IN1 O1
gramming device

Other modules
D1 IN2 O2
D2 IN3 -
D3 IN4 -
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used

Inductive sensors
P3 not used
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Relative humidity 90 % , not condensed
Degree of soiling 2
Mechanical specifications
Photoelectric

Protection degree IP20 according to EN 60529


sensors

Connection removable terminals


rated connection capacity:
rigid/flexible (with and without wire-end ferrules):
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

0.25 mm2 ... 2.5 mm2


for multiple-wire connection with two wires of equal cross-sec-
tion:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Rotary encoders

Mass 80 g
Mounting DIN rail
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 143
VBA-4E-KE1-Z

AS-Interface sensor-/actuator module VBA-4E-KE1-Z


Dimensions
Masters and
Gateways

50.5
22.5 48.5
Extender, Repeaters
Power Supplies,

99.6
Safety at work

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

4 inputs IN1 ... IN4


Field application
I/O Modules

AS-Interface -
I+
Order code AS-Interface + IN
IN
VBA-4E-KE1-Z
KE1 switch cabinet module
4 inputs
Analogue modules

ADDR

Features
• A/B slave with extended addressing
PWR
possibility for up to 62 slaves
FAULT
• Housing with removable terminals
Other modules

• Communication monitoring
• Inputs for 2-wire sensors and
mechanical contacts
• Addressing jack
Inductive sensors

• Power supply of inputs from the


module
• Function display for bus, external
auxiliary voltage and inputs Indicating/operating means

IN1 IN2 IN3 IN4


I+ 1 I+ 2 I+3 I+ 4
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 2 3 4
IN
FAULT
Rotary encoders

PWR
ADDR

AS-i + AS-i
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
144 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-4E-KE1-Z
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E-KE1 AS-Interface coupling
Slave type A/B slave
module is a cabinet module with 4 inputs.
Indicators/operating means The housing, only 22.5 mm in width and
LED FAULT error display; LED red 48.5 mm in height, takes up little place in the
red: communication error or address is 0
switch cabinet. The module is mounted by
LED PWR AS-Interface voltage; LED green
snapping onto the 35 mm DIN rail in accord-

Extender, Repeaters
LED IN switching state (input); 4 LED yellow

Power Supplies,
ance with EN 50022.
Electrical specifications Plug-in terminals are used for connection. 4-
Protection class III way terminal blocks (black) are used for the
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface inputs. The AS-Interface is connected via a
Rated operational current Ie ≤ 25 mA (without sensors) / max. 60 mA double terminal block (yellow).
Overvoltage protection Ue: Over voltage category III, safe isolated power supplies The supply of the inputs and the connected
(PELV)
sensors occurs internally via the module
Input

Safety at work
(from AS-Interface). An LED on the front con-
Number/Type 4 inputs for 2-wire sensors (PNP), DC or for mechanical con- trol plate is used to display the current
tacts
switching state for each input.
Input current ≤ 8 mA (limited internally)
Switching point according to DIN EN 61131-2 (Type 2)
0 (unattenuated) ≤ 2 mA Accessories
1 (attenuated) ≥ 4 mA
VBP-HH1

Control cabinet
Signal delay < 2 ms (input/AS-Interface)
Hand-held programming device

I/O Modules
Signal frequency ≤ 250 Hz
Programming instructions VAZ-PK-1,5M-V1-G
Profile S-0.A.0 Connection cable module/hand-held pro-
IO code 0 gramming device
ID code A
ID1 code 7

Field application
ID2 code 0

I/O Modules
Data bits (function via AS-Interface) Input
D0 IN1
D1 IN2
D2 IN3
D3 IN4

Analogue modules
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used
P3 not used
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)

Other modules
Relative humidity 90 % , not condensed
Degree of soiling 2
Mechanical specifications
Protection degree IP20 according to EN 60529
Connection removable terminals
rated connection capacity:

Inductive sensors
rigid/flexible (with and without wire-end ferrules):
0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-sec-
tion:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Mass 80 g
Mounting DIN rail
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 145
VAA-4EA-K3-ZE/E2

AS-Interface sensor-/actuator module VAA-4EA-K3-ZE/E2


Dimensions
Masters and
Gateways

71 20.5
Extender, Repeaters
Power Supplies,

63

75
Safety at work

ø4
63 39
Control cabinet

Electrical connection
I/O Modules

U
®
2
7 IN+
AS-Interface - 8
IN+
Field application

4
AS-Interface -
I/O Modules

1 13
IN1
AS-Interface +
Order code 3 14
IN2
AS-Interface +
VAA-4EA-K3-ZE/E2 15
IN3
16 IN4
Junction box modul
for 3-wire
4 inputs (PNP) and 4 electronic outputs 5
Analogue modules

IN- sensors
6 IN-

17
ADDR OUT1
Features 18
OUT2
• AS-Interface certificate 19
OUT3 Load
• Inputs for 2- and 3-wire sensors 20
OUT4
Other modules

• Addressing jack 9
OUT-
10
• Power supply of the inputs and PWR OUT-
outputs from the external auxiliary 12 AUX+ for connection
11
voltage AUX- of UAUX

• Function display for bus, ext. auxiliary


Inductive sensors

voltage, inputs and outputs

Indicating/operating means
Photoelectric

Addressing jack
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

PWR

IN1 IN2 IN3 IN4 OUT1 OUT2 OUT3 OUT4 AE


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
146 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-K3-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-K3-ZE/E2 AS-Interface cou-
Slave type Standard slave
pling module is a junction box module with
Indicators/operating means 4 inputs and 4 electronic outputs. Mechani-
LED PWR dual-LED green/red cal contacts and 2- and 3-wire sensors can
green: AS-Interface voltage, normal operation
red: communication error or address 0
be connected to the inputs.
The design of this module makes it particu-

Extender, Repeaters
LED IN switching state (input); 4 LED yellow

Power Supplies,
LED OUT switching state (output); 4 LED yellow
larly suitable for operation within a junction
LED AE ext. auxiliary voltage UAUX; LED green
box. Its housing, only 39 mm thick, occupies
little space in an installation. The VAA-4EA-
Electrical specifications
K3-ZE/E2 is installed by snapping it onto the
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
35 mm DIN Rail per EN 50022.
Protection class III
Screw terminals are available, for connecting
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
the inputs and outputs or the AS-Interface
Rated operational current Ie ≤ 60 mA

Safety at work
cable. These permit the connection of con-
Input ductors of up to 2.5 mm2. The inputs and
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC outputs of the module are supplied externally
Supply from external auxiliary voltage UAUX with 24 V DC. The external power supply
Current loading capacity ≤1A may be directly connected to the module.
Input current ≤ 8 mA (limited internally) Separate terminals are available for the sup-
Switching point ply of sensors/actuators, which are con-

Control cabinet
0 (unattenuated) ≤ 1.5 mA nected to the respective lines of the

I/O Modules
1 (attenuated) ≥ 4 mA sensors/actuators (see connection dia-
Output gram). A green LED indicates if the external
Number/Type 4 electronic outputs, PNP power supply is available. The module itself
Supply from external auxiliary voltage UAUX is supplied via the AS-Interface cable. The
Current 500 mA per output outputs can be loaded with up to 0.5 A per
Voltage ext. auxiliary voltage UAUX - 0.5 V channel.

Field application
The current switching state of each input and

I/O Modules
Programming instructions
Profile S-7.F output is indicated by a yellow LED, located
IO code 7 on the unit's front panel.
ID code F The power supply through AS-Interface is
Data bits (function via AS-Interface) input output indicated by a dual LED, which is also used
D0 IN1 OUT1 to indicate the address of zero, and for com-

Analogue modules
D1 IN2 OUT2 munication monitoring.
D2 IN3 OUT3 A programming jack is integrated into the
D3 IN4 OUT4 unit, for address configuration before or after
Parameter bits (programmable via AS-i) function installation. It permits a connection to the
P0 communication monitoring hand-held programming device.
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs Accessories

Other modules
maintain their condition
P1 not used VBP-HH1
P2 not used Hand-held programming device
P3 not used
VAZ-PK-1,5M-V1-G
Ambient conditions
Connection cable module/hand-held pro-
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
gramming device

Inductive sensors
Mechanical specifications
Protection degree IP20 according to EN 60529
Connection terminal connection ≤ 2.5 mm2
Mass 110 g
Mounting DIN rail or screw mounting
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 147
VAA-4A-K3-R

AS-Interface actuator module VAA-4A-K3-R


Dimensions
Masters and
Gateways

71 20.5
Extender, Repeaters
Power Supplies,

63

75
Safety at work

ø4
63 39
Control cabinet

Electrical connection
I/O Modules

U
®
Field application

2
AS-Interface -
I/O Modules

4
Order code AS-Interface -
5
1 OUT1o
AS-Interface + 6 OUT1c
VAA-4A-K3-R 3 13 OUT1
AS-Interface +
Junction box module
4 relay outputs
Analogue modules

7
8 OUT2o
15
OUT2c
OUT2

Features 9
10 OUT3o
ADDR OUT3c
• AS-Interface certificate 17 OUT3
• Addressing jack
Other modules

• Function display for outputs 11


OUT4o
12
OUT4c
• 4 potential-free switch-contacts 19 OUT4

PWR
Inductive sensors

Indicating/operating means
Photoelectric

Addressing jack
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Pwr

OUT1 OUT2 OUT3 OUT4 AE


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
148 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface actuator module VAA-4A-K3-R
Technical data Function

Masters and
General specifications

Gateways
The VAA-4A-K3-R AS-Interface coupling
Slave type Standard slave
module is a junction box module with 4 relay
Indicators/operating means outputs. The design of this module makes it
LED PWR AS-Interface voltage; LED green particularly suitable for operation within a
LED OUT switching state (output); 4 LED yellow junction box. Its housing, only 39 mm thick,
Electrical specifications occupies little space in an installation. The

Extender, Repeaters
Power Supplies,
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface VAA-4A-K3-R is installed by snapping it onto
Rated operational current Ie ≤ 40 mA the 35 mm DIN rail per EN 50022.
Output Screw terminals are available for connecting
Number/Type 4 relay outputs the outputs and the AS-Interface cable.
Contact loading 24 V DC, 500 mA per output, PELV These permit the connection of conductors
(protection class 3 according to VDE 0106/IEC 364-4-41) of up to 2.5 mm2. Each output is switched via
Lifetime 3 x 107 switching cycles a relay, which can be loaded to 24 V DC and

Safety at work
Programming instructions 0.5 A.
Profile S-8.0 The actuators connected to the module are
IO code 8 supplied externally (see connection dia-
ID code 0 gram). The module itself is supplied through
Data bits (function via AS-Interface) input output the AS-Interface cable. The AS-Interface
D0 IN4 O4 supply voltage is indicated by a green LED.
D1 - OUT2 The current switching state of each output is

Control cabinet
indicated by a yellow LED, located on the

I/O Modules
D2 - OUT3
D3 - OUT4 unit's front panel.
Parameter bits (programmable via AS-i) function Should there be an interruption to bus com-
P0 not used munications (e. g. failure of the master), the
P1 not used outputs maintain their current switch status
P2 not used while power is supplied.
P3 not used For address configuration before or after

Field application
installation, a programming jack is integrated

I/O Modules
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K) into the unit. It permits a connection to the
Storage temperature -25 ... 85 °C (248 ... 358 K) hand-held programming device.
Mechanical specifications
Protection degree IP20 according to EN 60529 Accessories
Connection terminal connection ≤ 2.5 mm2

Analogue modules
Mass 110 g
VBP-HH1
Mounting DIN rail or screw mounting Hand-held programming device
VAZ-PK-1,5M-V1-G
Connection cable module/hand-held pro-
gramming device

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 149
AS-Interface - Field modules
5.2 Field modules
Masters and
Gateways

There are three designs available as standard field modules in protection


class IP67:
• Flat housing with M12 connector (G2 design)
Extender, Repeaters

• Field modules with cable glands (G4 design)


Power Supplies,

• Compact modules with M8 connector (G6 design)


In the G2 series with M12 connector, the cable as well as the module can
be quickly exchanged in case of failure without requiring an electrician. The
flat cable can be inserted in two directions, making cable layout simpler. An
addressing jack makes the module easy and quick to address using the
Safety at work

VBP-HH1 hand-held. Due to its small height, this series is well-suited even
when space is short.
Communications are monitored and in case of failure, the outputs can be
powered off. Devices in two sizes (4 ports/8 ports) and in PNP or NPN ver-
sions are available. Dual sensors or 4-wire sensors can be connected di-
Control cabinet

Only one screw necessary


I/O Modules

rectly to the module with 2 signal inputs on an M12 connector. In most G2


on the housing top
modules, the inputs from pin 2 and pin 4 are bridged from two neighboring
spots for this reason. If only one signal input is to be used, however, a three-
strand connector cable should be used.
Field application
I/O Modules

The G4 series, in two sizes for the input and input/output module, already
include the cable entry glands. An already completed wiring job is thus par-
ticularly simple and cost-effective to extend.
Connection is performed using cage-clamp terminals, which require no
strand end sleeves. For connection to the AS-Interface flat cable, the
Analogue modules

U-G1F base (AS-Interface only) is required for the input modules, and the
U-G1FF base (AS-Interface plus external power supply) is required for the
input/output modules.
For address configuration, the modules can be plugged directly into the
handheld. If the U-1GFA or U-1GFFA based with addressing jacks are
Other modules

used, they can also be addressed through the base. Round cables can also
be used for the AS-Interface cable. In this case, the U-G1P or U-G1PP base
is required.
There are versions available for contact and two-wire sensors, for NAMUR
sensors as per IEC 60947-5-6, and for three-wire sensors in PNP or NPN
Inductive sensors

technologies.

The G6 series, in two sizes (4 ports/8 ports), is a good choice when space
is at a premium (robotics or handling systems). By using M8 plug connec-
tors to connect sensors, compactness and flexibility can be combined.
Photoelectric

Using the VAZ-2T5-G2 splitter box, up to five G6 compact modules can be


sensors

connected via one M12 connector cable, which is also used for address
configuration. If only a few G6 modules must be connected, this can also be
done using a VAZ-2T1-FK-1M-PUR-V1-W simple junction box.
Issue date 2004-11-19 - Catalogue AS-Interface 2004

The short circuit protected inputs supply the sensors with max. 200 mA.
Rotary encoders

Contacts or two-wire sensors can also be connected, using Pin 4 (Signal)


and Pin 3 (GND). A maximum of 0.5 A per output and 2 A per module is al-
lowable. The modules provide communication monitoring as well as a func-
tion display for the bus, external auxiliary power, and the inputs and outputs.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
150 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Field modules
Overview of switch cabinet and junction box modules

Masters and
Gateways
(Sorted by design. Dimensions and connection type can be found in the corresponding data sheets.)

Design Type code Inputs Outputs External power supply Page

Extender, Repeaters
VBA-4E3A-G2-ZA/EA2 4 3 Outputs (VAUX) 152

Power Supplies,
VBA-8E-G2-ZA 8 - - 156

VAA-4EA-G2-ZE/E2 4 4 Outputs (VAUX) 160


G2

Safety at work
VAA-2EA-G2-ZE/E2 2 2 Outputs (VAUX) 162

VBA-2E2A-G2-ZA/EA2 2 2 Outputs (VAUX) 154

VBA-4E-G2-ZA 4 - - 158

Control cabinet
I/O Modules
VAA-2*EA-G2-ZE/E2 2 2 - 164

VAA-4E-G2-ZE 4 - - 166

VAA-4A-G2-E2 - 4 Outputs (VAUX) 168

Field application
I/O Modules
VBA-4E3A-G4-ZE/E2 4 3 Outputs (VAUX) 170

VAA-4EA-G4-ZE/E2 4 4 Outputs (VAUX) 176

Analogue modules
VAA-2EA-G4-ZE/E2 2 2 Outputs (VAUX) 178
G4
VBA-2E2A-G4-ZE/E2 2 2 Outputs (VAUX) 172

VBA-4E-G4-ZE 4 - - 174

Other modules
VAA-4E-G4-Z 4 two-wire - - 180

VAA-4E-G4-N 4 NAMUR - - 182

Inductive sensors
VAA-4EA-G6-ZE/E2 4 4 Outputs (VAUX) 184

G6
VAA-2EA-G6-ZE/E2 2 2 Outputs (VAUX) 186
Photoelectric
sensors

VAA-4E-G6-ZE 4 - - 188

VAA-4A-G6-E2 - 4 Outputs (VAUX) 190


Issue date 2004-11-19 - Catalogue AS-Interface 2004

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 151
VBA-4E3A-G2-ZA/EA2

AS-Interface sensor-/actuator module VBA-4E3A-G2-ZA/EA2


Dimensions
Masters and
Gateways

150

18,7
Extender, Repeaters
Power Supplies,

4 73,5 34,5
Base is sold separately
Safety at work

36
60

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
IN1 IN3
1 IN+ IN+
Sensor +
2
IN2 IN4
AS-Interface -

4
3
IN1 IN3
AS-Interface + Sensor - IN- IN-
Field application

5
FG FG for 3-wire
I/O Modules

IN2 IN4 sensors


Order code Sensor + 1 IN+ IN+
2
(nc) (nc)
VBA-4E3A-G2-ZA/EA2 4
IN2 IN4
Sensor - 3
G2 flat module ADDR IN- IN-
5 for 3-wire
FG FG
4 inputs (PNP) and 3 electronic outputs sensors
Analogue modules

1 OUT1
(nc)
4
OUT1
3
OUT- Load
2
OUT2
Features 5
FG
PWR
• AS-Interface certificate 1 OUT2
(nc)
4
FAULT OUT2
• Protection degree IP67 3
OUT- Load
Other modules

2
• A/B slave with extended addressing 5
(nc)
FG
possibility for up to 62 slaves
1 OUT3
• Addressing jack (nc)
4
OUT3
3
• Flat cable connection with cable AUX
2
OUT- Load
piercing technique, variable flat cable AUX+ (nc)
5
FG
Inductive sensors

guide AUX-
Functional ground (FG)
• Communication monitoring Ground connection via mounting base

• Inputs for 2-, 3-, and 4-wire sensors


Indicating/operating means
• Power supply of outputs from the
external auxiliary voltage
• Supply for inputs from AS-Interface
Photoelectric
sensors

• Ground connection (FE) possible


• Function display for bus, ext. auxiliary
ADDR
4

4
1

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

voltage, inputs and outputs


OUT2
5

5
IN2

IN4

• Detection of overload on sensor


2

2
3

3
Rotary encoders

supply
FAULT

• Detection of output overload


OUT1
IN1

PWR
IN3

OUT3

AUX
1

1
2

2
5

5
4

4
3

3
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
152 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-4E3A-G2-ZA/EA2
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E3A-G2-ZA/EA2 is an AS-Inter-
Slave type A/B slave
face module with 4 Inputs and 3 outputs.
Indicators/operating means Mechanical contacts (e. g. push buttons) as
LED FAULT error display; LED red well as 2-, 3- and 4-wire sensors can be con-
red: communication error or address is 0
red flashing: overload of sensor power supply or outputs
nected to the inputs. The outputs are elec-
tronic outputs, which can be collectively

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green
loaded with 24 V DC and 2 A or 1.5 A per
LED IN switching state (input); 4 LED yellow
output.
LED OUT switching state (output); 3 LED yellow
The IP67 flat module is ideal for applications
in the field. An addressing jack is integrated
Electrical specifications
in the module.
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
(protection class 3 according to VDE 0106/IEC 364-4-41)
The connection for the sensors/actuators is
Protection class III
via M12 x 1 screw connections. An LED is

Safety at work
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
provided on the top of the module, for each
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA
channel, to indicate the current switching sta-
tus. Similarly, an LED is provided to monitor
Input
the AS-Interface communication and to indi-
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
alternative 2 inputs for 4-wire sensors (PNP), DC
cate that the module has the address 0.
Supply from AS-Interface
LEDs are also provided to indicate AS-Inter-
Voltage 21 ... 31 V
face voltage and external power supply.

Control cabinet
The mounting plate U-G2FF is used as

I/O Modules
Current loading capacity ≤ 200 mA (TB ≤ 40 °C),
≤ 150 mA (TB ≤ 60 °C), overload-proof and short-circuit proof standard for the connection to the AS-Inter-
Input current ≤ 8 mA (limited internally) face flat cable and the external 24 V DC sup-
Switching point according to DIN EN 61131-2 (Type 2) ply. The specially designed base enables the
0 (unattenuated) ≤ 2 mA user to connect flat cable from both sides.
1 (attenuated) ≥ 4 mA The device incorporates communication
monitoring, which switches off power to the

Field application
Output
outputs if no communication has taken place

I/O Modules
Number/Type 3 electronic outputs, PNP, overload and short-circuit proof
Supply from external auxiliary voltage UAUX on the AS-Interface line for longer than
Current 4 A total, 40 ms.
OUT 1, OUT 2: 2 A per output, An overloading of the internal input supply or
OUT 3: 1.5 A of the outputs is signalled to the AS-interface
Voltage ≥ (UAUX - 0,5 V) master via the "Peripheral fault" function.

Analogue modules
Programming instructions Communication via the AS-Interface remains
Profile S-7.A.2 intact.
IO code 7
ID code A Note:
ID1 code 7 The mounting base for the module is sold
ID2 code 2 separately.
Data bits (function via AS-Interface) input output
D0 IN1 OUT1

Other modules
Accessories
D1 IN2 OUT2
D2 IN3 OUT3 VBP-HH1
D3 IN4 - Hand-held programming device
Parameter bits (programmable via AS-i) function
P0 not used VAZ-PK-1,5M-V1-G
P1 not used Connection cable module/hand-held pro-

Inductive sensors
P2 not used gramming device
P3 not used
VAZ-FK-ED-G2
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
AS-Interface end seal for G2 modules
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications Matching system components
Protection degree IP67 according to EN 60529 U-G2FF
Photoelectric

Connection cable piercing method


Mounting plate for connection to flat ca-
sensors

flat cable yellow/flat cable black


inputs/outputs: M12 round connector ble (AS-Interface and external auxiliary
Mass 150 g power)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Mounting Mounting base

Notes
Rotary encoders

For 4-wire sensors, it is only possible to use plug-in slot IN1 or IN3 for inputs 1+2 or 3+4
(jumpered internally).
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 153
VBA-2E2A-G2-ZA/EA2

AS-Interface sensor-/actuator module VBA-2E2A-G2-ZA/EA2


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

IN3

AS-Interface -
Sensor + 1
IN+
4
IN3
Field application

3
AS-Interface + Sensor - IN-
I/O Modules

2
IN4
Order code 5
FG
for 3-wire
sensors
VBA-2E2A-G2-ZA/EA2 1
IN4
IN+
4
G2 flat module IN4
3
2 inputs (PNP) and 2 electronic outputs ADDR IN-
2
Analogue modules

5
(nc)
FG for 3-wire
sensors
OUT1
PWR 1
(nc)
Features 4
OUT1
FAULT 3
OUT- Load
• AS-Interface certificate 2
OUT2
5
• Protection degree IP67 FG
OUT2
Other modules

• A/B slave with extended addressing 1


(nc)
4
possibility for up to 62 slaves 3
OUT2
AUX OUT- Load
• Addressing jack 2
AUX+ (nc)
5
FG
• Flat cable connection with cable AUX-

piercing technique, variable flat cable


Inductive sensors

guide Functional ground (FG)


Ground connection via mounting base
• Communication monitoring
• Inputs for 2-, 3-, and 4-wire sensors
Indicating/operating means
• Power supply of outputs from the
external auxiliary voltage
• Supply for inputs from AS-Interface 4
Photoelectric

1 3 4
sensors

• Ground connection (FE) possible 5 5


3 2 2 1
• Function display for bus, ext. auxiliary OUT1 OUT2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

voltage, inputs and outputs


4 1 3 4
• Detection of overload on sensor 5 5
Rotary encoders

supply 3 2 2 1

• Detection of output overload IN3 IN4

PWR
FAULT
ADDR
AUX
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
154 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-2E2A-G2-ZA/EA2
Technical data Function

Masters and
General specifications

Gateways
The VBA-2E2A-G2-ZA/EA2 is an AS-Inter-
Slave type A/B slave
face interface module with 2 Inputs and
Indicators/operating means 2 outputs. Mechanical contacts (e. g. push
LED FAULT error display; LED red buttons) as well as 2-, 3- and 4-wire sensors
red: communication error or address is 0
red flashing: overload of sensor power supply or outputs
can be connected to the inputs. The outputs
are electronic outputs, which can be loaded

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green
to 24 V DC and 1 A per output.
LED IN switching state (input); 2 LED yellow
The IP67 flat module is ideal for applications
LED OUT switching state (output); 2 LED yellow
in the field. An addressing jack is integrated
in the module.
Electrical specifications
Connection to the sensors/actuators is pro-
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV
vided via M12 x 1 screw connections. An
Protection class III
LED is provided for each channel, on the top
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface

Safety at work
of the module, to indicate the current switch-
Rated operational current Ie ≤ 40 mA (without sensors) / max. 140 mA
ing status. Similarly, an LED is provided to
Input monitor the AS-Interface communication and
Number/Type 2 inputs for 2- or 3-wire sensors (PNP), DC to indicate that the module has the
alternative 1 input for 4-wire sensor (PNP), DC
address 0. LEDs are also provided to indi-
Supply from AS-Interface
cate the AS-Interface voltage and the exter-
Voltage 21 ... 31 V
nal power supply.
≤ 100 mA (TB ≤ 40 °C),

Control cabinet
Current loading capacity
The U-G3FF mounting base is normally used

I/O Modules
≤ 75 mA (TB ≤ 60 °C), overload-proof and short-circuit proof
Input current ≤ 8 mA (limited internally)
for the connection of the AS-Interface flat
Switching point according to DIN EN 61131-2 (Type 2)
cable and the external 24 V DC power sup-
0 (unattenuated) ≤ 2 mA
ply. The specially designed base enables the
1 (attenuated) ≥ 4 mA
user to connect flat cable from both sides.
The device is equipped with communication
Output
monitoring, which switches off power to the

Field application
Number/Type 2 electronic outputs, PNP overload and short-circuit proof
inputs if no communication has taken place

I/O Modules
Supply from external auxiliary voltage UAUX
for longer than 40 ms.
Current 1 A per output
An overloading of the internal power supply
Voltage ≥ (UAUX - 0,5 V)
or of the outputs is signalled to the AS-inter-
Programming instructions
face master via the "Peripheral fault" func-
Profile S-B.A.2 tion. Communication via the AS-Interface
IO code B

Analogue modules
remains intact.
ID code A
ID1 code 7 Note:
ID2 code 2 The mounting base for the module is sold
Data bits (function via AS-Interface) input output separately.
D0 IN4 O4
D1 - OUT2
D2 IN3 - Accessories

Other modules
D3 IN4 -
VBP-HH1
Parameter bits (programmable via AS-i) function
Hand-held programming device
P0 not used
P1 not used VAZ-PK-1,5M-V1-G
P2 not used Connection cable module/hand-held pro-
P3 not used
gramming device

Inductive sensors
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K) VAZ-FK-ED-G2
Storage temperature -25 ... 85 °C (248 ... 358 K) AS-Interface end seal for G2 modules
Mechanical specifications
Protection degree IP67 according to EN 60529 Matching system components
Connection cable piercing method
flat cable yellow/flat cable black U-G3FF
inputs/outputs: M12 round connector Mounting plate for connection to flat ca-
Photoelectric

Mass 100 g ble (AS-Interface and external auxiliary


sensors

Mounting Mounting base


power)
Notes
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

In the case of 4-wire sensors, you must use slot IN3 for the inputs (internally bridged).
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 155
VBA-8E-G2-ZA

AS-Interface sensor module VBA-8E-G2-ZA


Dimensions
Masters and
Gateways

150

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

IN1.1 IN1.3
1 1
U
®
sensor + IN+ IN+
2
LISTED 57M3
IND. CONT. EQ. PWR/ IN2 IN4
CLASS 2 CIRCUIT ONLY 4
FAULT IN1 IN3
Field application

sensor - 3
IN- IN-
I/O Modules

5
FG FG for 3-wire
Order code sensors

VBA-8E-G2-ZA IN1.2 IN1.4


sensor + 1 IN+ IN+
AS-Interface + 2
G2 flat module 1 4
(nc) (nc)
AS-Interface - IN2 IN4
8 inputs (PNP) 3
Analogue modules

ADDR sensor - IN- IN-


5
FG FG for 3-wire
sensors
IN2.1 IN2.3
Features sensor + 1 IN+ IN+
2
IN2 IN4
• AS-Interface certificate 4
IN1 IN3
sensor - 3
• Protection degree IP67 IN- IN-
5
FG FG for 3-wire
Other modules

• Does require two addresses AS-Interface + sensors


IN2.2 IN2.4
• Double A/B slave with extended 2 AS-Interface - 1
sensor + IN+ IN+
ADDR 2
addressing possibility for up to 62 (nc) (nc)
4
slaves 2 IN2 IN4
sensor - 3
IN- IN-
5
• Double addressing jack PWR/ FG FG for 3-wire
FAULT sensors
Inductive sensors

• Flat cable connection with cable Functional ground (FG)


piercing technique, variable flat cable Ground connection via mounting base

guide
• Communication monitoring Indicating/operating means
• Inputs for 2-, 3-, and 4-wire sensors
• Supply for inputs from AS-Interface
Photoelectric
sensors

• Ground connection (FE) possible


1

• Function display for bus and inputs


4
4

1
1

IN2.4
IN2.2

ADDR

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


IN1.2

IN1.4

5
5

• Detection of overload on sensor


supply
2
2

3
3

3
Rotary encoders

FAULT

FAULT
PWR/

PWR/
1

1
2

2
IN1.1

IN2.1

IN2.3
IN1.3
5

CLASS 2 CIRCUIT ONLY


1

IND. CONT. EQ.


4

4
3

LISTED 57M3
U
®
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
156 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VBA-8E-G2-ZA
Technical data Function

Masters and
General specifications

Gateways
The VBA-8E-G2-ZA is an AS-Interface I/O
Slave type Double A/B slave
module with 8 inputs. Both 2-wire and 3-wire
Indicators/operating means sensors can be connected to the inputs as
LED PWR/FAULT 2 dual LED green/red well as 4-wire sensors and mechanical con-
green:AS-Interface voltage
red: communication error or address 0
tacts (for example a pushbutton switch).
The IP67 flat module is ideally suited for use

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state(input); 8 LED yellow in the field. The module uses two addresses
Electrical specifications and behaves externally like two separate 4E
Protection class III
modules. Inputs 1.1 ... 1.4 are assigned to
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Slave 1, while inputs 2.1 ... 2.4 are assigned
Rated operational current Ie ≤ 80 mA (without sensors) / max. 280 mA
to Slave 2. A double addressing socket is
integrated into the module for separate
Input
addressing of the two slaves. The slaves
Number/Type 2x 4 inputs for 2- or 3-wire sensors (PNP), DC

Safety at work
alternative 2x 2 inputs for 4-wire sensors (PNP), DC
must be addressed before the unit is placed
Supply from AS-Interface
in service.
Voltage 21 ... 31 V
The connection to the sensors is set up by
Current loading capacity ≤ 200 mA, overload and short-circuit protected
means of M12 x 1-screw connections. An
Input current ≤ 8 mA (limited internally)
LED is available for each channel to display
Switching point according to DIN EN 61131-2 (Type 2)
the current switching status. It is located on
0 (unattenuated) ≤ 2 mA
the top side of the module. An LED is also

Control cabinet
available for each of the slaves for monitoring

I/O Modules
1 (attenuated) ≥ 4 mA
AS-Interface communication and for display-
Programming instructions
ing that a slave has 0 as an address. An
Profile S-0.A.2
overload on the sensor power supply is
IO code 0
shown by both LEDs.
ID code A
By default, the U-G2FF mounting plate is
ID1 code 7
used to connect to the AS-Interface flat

Field application
ID2 code 2
cable. This lower section allows for contact

I/O Modules
Data bits (function via AS-Interface) Input slave 1 input slave 2
with the flat cable from both sides. If input
D0 IN1.1 IN2.1
and output modules are used in a single sys-
D1 IN1.2 IN2.2
tem, the flat cable can also be inserted into
D2 IN1.3 IN2.3
the lower section for external power supply.
D3 IN1.4 IN2.4
The module will not access this line. The
Parameter bits (programmable via AS-i) function

Analogue modules
advantage this offers is that both flat cables
P0 not used
can be laid essentially in parallel without
P1 not used
introducing the danger that an incorrect con-
P2 not used
nection would destroy the module.
P3 not used
Ambient conditions
Note:
Ambient temperature -25 ... 60 °C (248 ... 333 K) The mounting plate for the module must be
Storage temperature -25 ... 85 °C (248 ... 358 K) ordered separately.

Other modules
Mechanical specifications
Protection degree IP67 according to EN 60529
Connection cable piercing method
Accessories
flat cable yellow
inputs: M12 round connector
VBP-HH1
Mass 135 g Hand-held programming device
Mounting Mounting base

Inductive sensors
VAZ-PK-1,5M-V1-G
Connection cable module/hand-held pro-
Notes
gramming device
With 4-wire sensors, only plug-in slots IN1.1, IN1.3, IN2.1 or IN2.3 can be used from inputs
VAZ-FK-ED-G2
IN1.1+IN1.2, IN1.3+IN1.4, IN2.1+IN2.2 or IN2.3+IN2.4 (jumpered internally).
AS-Interface end seal for G2 modules
VAZ-V1-B1
Photoelectric

Blanking plug for M12 addressing socket


sensors

Matching system components


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

U-G2FF
Mounting plate for connection to flat ca-
ble (AS-Interface and external auxiliary
Rotary encoders

power)
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 157
VBA-4E-G2-ZA

AS-Interface sensor module VBA-4E-G2-ZA


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

IN1 IN3
U® Sensor +
1 IN+ IN+
2
IN2 IN4
Field application

AS-Interface - 4
IN1 IN3
I/O Modules

AS-Interface + 3
Sensor - IN- IN-
Order code 5
FG FG for 3-wire
IN2 IN4 sensors
VBA-4E-G2-ZA 1
Sensor + IN+ IN+
2
G2 flat module (nc) (nc)
4
4 inputs (PNP) IN2 IN4
3
Analogue modules

Sensor - IN- IN-


ADDR 5
FG FG for 3-wire
sensors

Features
• AS-Interface certificate
• Protection degree IP67 FAULT
Other modules

• A/B slave with extended addressing PWR


possibility for up to 62 slaves
• Addressing jack
Functional ground (FG)
• Flat cable connection with cable Ground connection via mounting base
piercing technique, variable flat cable
Inductive sensors

guide
• Communication monitoring
• Inputs for 2-, 3-, and 4-wire sensors
Indicating/operating means
• Supply for inputs from AS-Interface
• Ground connection (FE) possible
4
Photoelectric

• Function display for bus and inputs 1 3 4


sensors

5 5
• Detection of overload on sensor 2 1
3 2
supply IN1 IN2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

4 1 3 4
5 5
Rotary encoders

3 2 2 1
IN3 IN4

PWR

FAULT
ADDR
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
158 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VBA-4E-G2-ZA
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E-G2-ZA is an AS-Interface inter-
Slave type A/B slave
face module with 4 Inputs. Mechanical con-
Indicators/operating means tacts (e. g. push buttons) as well as 2-, 3-
LED FAULT error display; LED red and 4-wire sensors can be connected to the
red: communication error or address is 0
red flashing: overload of sensor supply
inputs.
The IP67 flat module is ideal for applications

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED IN switching state (input); 4 LED yellow
in the field. An addressing jack is integrated
in the module.
Electrical specifications
The sensors are connected by means of
Protection class III
M12 x 1 screw connections. An LED is pro-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
vided for each channel to indicate the current
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA
switching status. Similarly, an LED is availa-
Input ble to monitor the AS-Interface communica-
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC

Safety at work
tion and the indication that the module has
alternative 2 inputs for 4-wire sensors (PNP), DC
the address 0.
Supply from AS-Interface
The mounting plate U-G3FF is used, as
Voltage 21 ... 31 V
standard, for connection to the AS-Interface.
Current loading capacity ≤ 200 mA (TB ≤ 40 °C),
≤ 150 mA (TB ≤ 60 °C), overload-proof and short-circuit proof
This lower section enables the flat cable to
Input current ≤ 8 mA (limited internally)
be contacted from both sides. If input and
Switching point according to DIN EN 61131-2 (Type 2)
output modules are used in a mixed system,

Control cabinet
the flat cable for the internal power supply

I/O Modules
0 (unattenuated) ≤ 2 mA
1 (attenuated) ≥ 4 mA
can be inserted in the lower section of this
module. The module does not access this
Programming instructions
cable. The advantage is that both flat cables
Profile S-0.A.2
can be laid in parallel, without the danger of
IO code 0
the module being destroyed by an incorrect
ID code A
connection.

Field application
ID1 code 7
An overloading of the internal input supply is

I/O Modules
ID2 code 2
signalled to the AS-Interface master via the
Data bits (function via AS-Interface) input output
"Peripheral fault" function. Communication
D0 IN1 -
via the AS-Interface remains unaffected.
D1 IN2 -
D2 IN3 -
Note:
D3 IN4 -

Analogue modules
The mounting base for the module is sold
Parameter bits (programmable via AS-i) function
separately.
P0 not used
P1 not used
P2 not used Accessories
P3 not used
VBP-HH1
Ambient conditions
Hand-held programming device
Ambient temperature -25 ... 60 °C (248 ... 333 K)

Other modules
Storage temperature -25 ... 85 °C (248 ... 358 K) VAZ-PK-1,5M-V1-G
Mechanical specifications Connection cable module/hand-held pro-
Protection degree IP67 according to EN 60529 gramming device
Connection cable piercing method
flat cable yellow VAZ-FK-ED-G2
inputs: M12 round connector
AS-Interface end seal for G2 modules
Mass 100 g

Inductive sensors
Mounting Mounting base
Matching system components
Notes U-G3FF
For 4-wire sensors, it is only possible to use plug-in slot IN1 or IN3 for inputs 1+2 or 3+4 Mounting plate for connection to flat ca-
(jumpered internally). ble (AS-Interface and external auxiliary
power)
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 159
VAA-4EA-G2-ZE/E2

AS-Interface sensor-/actuator module VAA-4EA-G2-ZE/E2


Dimensions
Masters and
Gateways

150

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

M12x1 quick disconnect



4 inputs IN1 ... IN4
AS-Interface - 1
Field application

Sensor + IN+
AS-Interface +
I/O Modules

Order code 2 IN
3
VAA-4EA-G2-ZE/E2 Sensor - IN1-
5
FG for 3-wire
G2 flat module
sensors
4 inputs (PNP) and 4 electronic outputs ADDR
Analogue modules

PWR
M12x1 quick disconnect
4 outputs OUT1 ... OUT4
1
IN-ERR OUT+
Features 4
OUT
COM-ERR 2
• AS-Interface certificate (nc) Load
3
OUT-
• Protection degree IP67 5
FG
Other modules

• Addressing jack
AUX+
• Flat cable connection with cable
piercing technique, variable flat cable AUX-

guide
• Communication monitoring, turn-off Functional ground (FG)
Inductive sensors

Ground connection via mounting base


• Inputs for 2- and 3-wire sensors
• Power supply of outputs from the
external auxiliary voltage
Indicating/operating means
• Power supply of inputs from the
module
• Ground connection (PE) possible
Photoelectric
sensors

• Function display for bus, ext. auxiliary


voltage, inputs and outputs
3

3
4

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


OUT3

OUT1

• Monitoring of sensor overloads


AUX
ERR
COM-
rd: IN-ERR
gn: PWR

5
IN3

IN1
2

2
1

1
Rotary encoders

IN4
OUT2

IN2
OUT4

3
2

2
ADDR

5
1

1
4

4
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
160 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-G2-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-G2-ZE/E2 is an AS-Interface
Slave type Standard slave
coupling module with 4 inputs and 4 outputs.
Indicators/operating means Mechanical contacts and 2- and 3-wire sen-
LED PWR AS-Interface voltage; LED green sors can be connected to the inputs. The out-
LED COM ERR communication error / address is 0; LED red puts are electronic outputs, which can be
LED AUX ext. auxiliary voltage UAUX; LED green loaded to 24 V DC and 2 A per output.

Extender, Repeaters
Power Supplies,
LED IN switching state (input); 4 LED yellow The IP67 flat module features an integrated
LED OUT switching state (output); 4 LED yellow addressing jack and is ideal for applications
LED IN-ERR overload of sensor power supply; LED red in the field.
Electrical specifications Connection to the sensors/actuators is pro-
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV vided via M12 x 1 screw connections. The
Protection class III current switching state of each channel is
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface indicated by an LED, located on the module's
≤ 40 mA (without sensors) / max. 240 mA

Safety at work
Rated operational current Ie top side. Similarly, an LED is provided to
Input monitor the AS-Interface communication and
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC to indicate that the module has the
Supply from AS-Interface address 0. If an AS-Interface communication
Voltage 21 ... 31 V error occurs, the outputs are de-energised in
Current loading capacity ≤ 200 mA (TB ≤ 40 °C), case the watchdog is active.
≤ 150 mA (TB ≤ 60 °C), short-circuit protected The input is monitored for short circuits.

Control cabinet
Input current ≤ 8 mA (limited internally) LEDs are also provided to indicate AS-Inter-

I/O Modules
Switching point face voltage and external power supply.
0 (unattenuated) ≤ 1.5 mA The U-G2FF mounting base is used as a
1 (attenuated) ≥ 4.5 mA standard connection to the AS-Interface flat
Output cable and to the external 24 V DC power
Number/Type 4 electronic outputs, PNP supply. The specially designed base enables
Supply from external auxiliary voltage UAUX the user to connect flat cables from both

Field application
sides. This means, for example, that 90°

I/O Modules
Current 2 A per output, 4 A total
Voltage ≥ (UAUX - 0,5 V) curves can be laid with very tight radii (varia-
Programming instructions ble flat cable guide).
Profile S-7.F
IO code 7 Note:
ID code F The mounting base for the module is sold

Analogue modules
Data bits (function via AS-Interface) input output separately.
D0 IN1 OUT1
D1 IN2 OUT2 Accessories
D2 IN3 OUT3
D3 IN4 OUT4 VBP-HH1
Parameter bits (programmable via AS-i) function Hand-held programming device
P0 communication monitoring
P0 = 1 (basic setting), monitoring = ON, i.e. if communication VAZ-PK-1,5M-V1-G

Other modules
fails, the outputs are de-energised Connection cable module/hand-held pro-
P0 = 0, monitoring = OFF, if communication fails, the outputs
maintain their condition
gramming device
P1 not used VAZ-FK-ED-G2
P2 not used
AS-Interface end seal for G2 modules
P3 not used
Ambient conditions

Inductive sensors
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Matching system components
Storage temperature -25 ... 85 °C (248 ... 358 K) U-G2FF
Mechanical specifications Mounting plate for connection to flat ca-
Protection degree IP67 according to EN 60529 ble (AS-Interface and external auxiliary
Connection cable piercing method power)
flat cable yellow/flat cable black
inputs/outputs: M12 round connector
Photoelectric

Mass 150 g
sensors

Mounting Mounting base


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 161
VAA-2EA-G2-ZE/E2

AS-Interface sensor-/actuator module VAA-2EA-G2-ZE/E2


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

M12x1 quick disconnect


IN1

AS-Interface -
Sensor + 1
IN+
AS-Interface + 4
IN1
Field application

2
IN1
I/O Modules

3
Sensor - IN-
Order code 5
FG for 3-wire
VAA-2EA-G2-ZE/E2 IN2 sensors
1
IN+
G2 flat module 4
ADDR IN2
2
2 inputs (PNP) and 2 electronic outputs IN2
3
Analogue modules

5
IN-
PWR FG
OUT3
FAULT 1
(nc)
Features 4
OUT3
2
• AS-Interface certificate (nc) Load
3
OUT-
5
• Protection degree IP67 FG
OUT4
Other modules

• Addressing jack 1
(nc)
4
• Flat cable connection with cable OUT4
2
(nc)
piercing technique, variable flat cable AUX+ 3
OUT-
AUX- 5
guide FG

• Communication monitoring, turn-off


Inductive sensors

Functional ground (FG)


• Inputs for 2- and 3-wire sensors Ground connection via mounting base
• Power supply of outputs from the
external auxiliary voltage
Indicating/operating means
• Power supply of inputs from the
module
• Ground connection (PE) possible 4
Photoelectric

1 3 4
sensors

• Function display for bus, ext. auxiliary 5 5

voltage, inputs and outputs 3 2 2 1


IN1 IN2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

• Monitoring of sensor overloads


4 1 3 4
5 5
Rotary encoders

3 2 2 1
OUT3 OUT4

PWR
FAULT
ADDR
AUX
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
162 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-2EA-G2-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-2EA-G2-ZE/E2 is an AS-Interface
Slave type Standard slave
coupling module with 2 inputs and 2 outputs.
Indicators/operating means Mechanical contacts and 2- and 3-wire sen-
LED FAULT error display; LED red sors can be connected to the inputs. The out-
red: communication error or address is 0
red flashing: overload of sensor supply
puts are electronic outputs, which can be
loaded to 24 V DC and 1.5 A per output.

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green
The IP67 flat module features an integrated
LED IN switching state (input); 2 LED yellow
addressing jack and is ideal for applications
LED OUT switching state (output); 2 LED yellow
in the field.
Connection to the sensors/actuators is pro-
Electrical specifications
vided via M12 x 1 screw connections. The
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
current switching state of each channel is
Protection class III
indicated by an LED, located on the module's
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface

Safety at work
top side. Similarly, an LED is provided to
Rated operational current Ie ≤ 40 mA (without sensors) / max. 190 mA
monitor the AS-Interface communication and
Input to indicate that the module has the
Number/Type 2 inputs for 2- or 3-wire sensors (PNP), DC address 0. If an AS-Interface communication
Supply from AS-Interface error occurs, the outputs are de-energised.
Voltage 21 ... 31 V The input circuit is monitored for short cir-
Current loading capacity ≤ 150 mA (TB ≤ 40 °C), cuits. LEDs are also provided to indicate AS-
≤ 120 mA (TB ≤ 60 °C), short-circuit proof

Control cabinet
Interface voltage and external power supply.

I/O Modules
Input current ≤ 8 mA (limited internally)
The U-G3FF mounting base is normally used
Switching point
for the connection of the AS-Interface flat
0 (unattenuated) ≤ 1.5 mA
cable and the external 24 V DC power sup-
1 (attenuated) ≥ 4.5 mA
ply. The specially designed base enables the
Output user to connect flat cables from both sides.
Number/Type 2 electronic outputs, PNP This means, for example, that 90° curves can

Field application
Supply from external auxiliary voltage UAUX be laid with very tight radii (variable flat cable

I/O Modules
Current 1.5 A per output guide).
3 A total (TB ≤ 40 °C), 2 A total (TB ≤ 60 °C)
Voltage ≥ (UAUX - 0,5 V)
Note:
Programming instructions
The mounting base for the module is sold
Profile S-3.F separately.
IO code 3

Analogue modules
ID code F
Data bits (function via AS-Interface) input output Accessories
D0 IN1 -
VBP-HH1
D1 IN2 -
Hand-held programming device
D2 - OUT3
D3 - OUT4 VAZ-PK-1,5M-V1-G
Parameter bits (programmable via AS-i) function Connection cable module/hand-held pro-

Other modules
P0 communication monitoring
gramming device
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs VAZ-FK-ED-G2
maintain their condition AS-Interface end seal for G2 modules
P1 not used
P2 not used Matching system components

Inductive sensors
P3 not used
Ambient conditions U-G3FF
Ambient temperature -25 ... 60 °C (248 ... 333 K) Mounting plate for connection to flat ca-
Storage temperature -25 ... 85 °C (248 ... 358 K) ble (AS-Interface and external auxiliary
Mechanical specifications power)
Protection degree IP67 according to EN 60529
Connection cable piercing method
flat cable yellow/flat cable black
Photoelectric

inputs/outputs: M12 round connector


sensors

Mass 100 g
Mounting Mounting base
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 163
VAA-2*EA-G2-ZE/E2

AS-Interface sensor-/actuator module VAA-2*EA-G2-ZE/E2


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

M12x1 quick disconnect


IN1/OUT3

Sensor + 1
IN+
4
IN1
Field application

2
OUT3
I/O Modules

AS-Interface - 3
Sensor - IN-
Order code AS-Interface +
5
FG for 3-wire
VAA-2*EA-G2-ZE/E2 IN2/OUT4 sensors
1
IN+
G2 flat module for motor starter 4
IN2
2
2 inputs/2 electronic outputs OUT4
3
Analogue modules

5
IN-
ADDR FG
OUT3
1
(nc)
Features 4
OUT3
2
• AS-Interface certificate (nc) Load
3
OUT-
5
• Protection degree IP67 FG
OUT4
Other modules

• Addressing jack 1
(nc)
PWR 4
• Flat cable connection with cable OUT4
2
(nc)
piercing technique, variable flat cable FAULT 3
OUT-
5
guide FG

• Communication monitoring, turn-off


Inductive sensors

Functional ground (FG)


• Two MOVISWITCH, controllable by Ground connection via mounting base
SEW
• Inputs for 2- and 3-wire sensors
Indicating/operating means
• Power supply of inputs and outputs
from the module
• Ground connection (PE) possible 4 1 3 4
Photoelectric
sensors

5 5
• Function display for bus, inputs and
3 2 2 1
outputs OUT3 OUT4
IN1 IN2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

• Monitoring of sensor overloads 4 1 3 4


5 5
Rotary encoders

3 2 2 1
OUT3 OUT4

PWR
FAULT
ADDR
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
164 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-2*EA-G2-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-2*EA-G2-ZE/E2 is an AS-Interface
Slave type Standard slave
coupling module with 2 inputs and 2 outputs.
Indicators/operating means The inputs and outputs are available via a
LED FAULT error display; LED red M12 x 1 socket. Mechanical contacts and 2-
red: communication error or address is 0
red flashing: overload of sensor supply
and 3-wire sensors can be connected to the
inputs. The outputs are powered via the

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED IN switching state (input); 2 LED yellow
internal sensor supply.
LED OUT switching state (output); 2 LED yellow
The module is used to drive motors with
decentralised motor controllers (MOVIS-
Electrical specifications
WITCH from SEW corporation). Each drive
Protection class III
requires a 24 V input and a 24 V output.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Connection to the sensors/actuators is pro-
Rated operational current Ie ≤ 30 mA (without sensors) / max. 180 mA
vided via M12 x 1 screw connections.
Input

Safety at work
The IP67 flat module features an integrated
Number/Type 2 inputs for 2- or 3-wire sensors (PNP), DC addressing jack and is ideal for applications
Supply from AS-Interface in the field. The current switching state of
Voltage 21 ... 31 V each channel is indicated by an LED located
Current loading capacity ≤ 150 mA (TB ≤ 40 °C), on the module's top side. The supply of the
≤ 120 mA (TB ≤ 60 °C), short-circuit proof
inputs and outputs is monitored for short cir-
Input current ≤ 8 mA (limited internally)
cuits. Similarly, an LED is provided to monitor

Control cabinet
Switching point
the AS-Interface communication and to indi-

I/O Modules
0 (unattenuated) ≤ 1.5 mA
cate that the module has the address 0. If an
1 (attenuated) ≥ 4.5 mA
AS-Interface communication error occurs,
Output the outputs are de-energised.
Number/Type 2 electronic outputs, PNP The U-G3FF mounting base is used as a
Supply from AS-Interface standard connection to the AS-Interface flat
Current limited by the current loading capacity of the module cable. The specially designed base enables

Field application
Programming instructions users to connect flat cables from both sides.

I/O Modules
Profile S-3.F This means, for example, that 90° curves can
IO code 3 be laid with very tight radii (variable flat cable
ID code F guide).
Data bits (function via AS-Interface) input output
D0 IN1 - Note:

Analogue modules
D1 IN2 - The mounting base for the module is sold
D2 - OUT3 separately.
D3 - OUT4
Parameter bits (programmable via AS-i) function
P0 communication monitoring
Accessories
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
VBP-HH1
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs Hand-held programming device
maintain their condition

Other modules
P1 not used VAZ-PK-1,5M-V1-G
P2 not used Connection cable module/hand-held pro-
P3 not used gramming device
Ambient conditions
VAZ-FK-ED-G2
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
AS-Interface end seal for G2 modules

Inductive sensors
Mechanical specifications
Protection degree IP67 according to EN 60529 Matching system components
Connection cable piercing method U-G3FF
flat cable yellow/flat cable black
inputs/outputs: M12 round connector Mounting plate for connection to flat ca-
Mass 100 g ble (AS-Interface and external auxiliary
Mounting Mounting base power)
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 165
VAA-4E-G2-ZE

AS-Interface sensor module VAA-4E-G2-ZE


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

M12 quick disconnect


IN1
1
U® 4
IN+
AS-Interface +
2 IN
Field application

AS-Interface - 3
I/O Modules

IN-
5
Order code FG
IN2
VAA-4E-G2-ZE 1
IN+ for 3-wire
4 sensors
G2 flat module 2 IN
4 inputs (PNP) 3
Analogue modules

IN-
5
FG
IN3
1
IN+
Features 4
2 IN
• AS-Interface certificate 3
IN-
5
• Protection degree IP67 FG
FAULT
IN4
Other modules

• Addressing jack PWR


1
IN+
4
• Flat cable connection with cable 2 IN
piercing technique, variable flat cable 3
IN-
guide 5
FG
• Inputs for 2- and 3-wire sensors
Inductive sensors

• Power supply of inputs from the Functional ground (FG)


Ground connection via mounting base
module
• Ground connection (PE) possible
Indicating/operating means
• Function display for bus and inputs
• Monitoring of sensor overloads
4
Photoelectric

1 3 4
sensors

5 5
3 2 2 1
IN1 IN2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

4 1 3 4
5 5
Rotary encoders

3 2 2 1
IN3 IN4

PWR

FAULT
ADDR
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
166 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VAA-4E-G2-ZE
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E-G2-ZE is an AS-Interface cou-
Slave type Standard slave
pling module with 4 inputs. Mechanical con-
Indicators/operating means tacts (e. g. push buttons) and 2- and 3-wire
LED FAULT error display; LED red sensors can be connected to the inputs.
red: communication error or address is 0
red flashing: overload of sensor supply
The IP67 flat module features an integrated
addressing jack and is ideal for applications

Extender, Repeaters
LED PWR AS-Interface voltage; LED green

Power Supplies,
LED IN switching state (input); 4 LED yellow
in the field.
The sensors are connected via M12 x 1
Electrical specifications
screw connections. The current switching
Protection class III
state of each channel is indicated by an LED.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Similarly, an LED is available to monitor the
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA
AS-Interface communication and the indica-
Input tion that the module has the address 0.
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC

Safety at work
The input is monitored for short circuits. In a
Supply from AS-Interface failure case, the module disconnects from
Voltage 21 ... 31 V the AS-Interface and an error is indicated.
Current loading capacity ≤ 200 mA (TB ≤ 40 °C), The U-G3FF mounting base is used as a
≤ 150 mA (TB ≤ 60 °C), short-circuit protected
standard connection to the AS-Interface. The
Input current ≤ 8 mA (limited internally)
specially designed base enables the flat
Switching point
cable to be contacted from both sides. This
≤ 1.5 mA

Control cabinet
0 (unattenuated)
means, for example, that 90° curves can be

I/O Modules
1 (attenuated) ≥ 4.5 mA
laid with very tight radii (variable flat cable
Programming instructions guide). If input and output modules are used
Profile S-0.0 in an application, the flat cable for the exter-
IO code 0 nal power supply can be placed in the base
ID code 0 of the module, since the module does not
Data bits (function via AS-Interface) input output access this line. The advantage is that both

Field application
D0 IN1 - flat cables can be placed in parallel without

I/O Modules
D1 IN2 - destroying the module due to a wrong con-
D2 IN3 - nection.
D3 IN4 -
Parameter bits (programmable via AS-i) function Note:
P0 not used The mounting base for the module is sold

Analogue modules
P1 not used separately.
P2 not used
P3 not used
Ambient conditions Accessories
Ambient temperature -25 ... 60 °C (248 ... 333 K) VBP-HH1
Storage temperature -25 ... 85 °C (248 ... 358 K) Hand-held programming device
Mechanical specifications
Protection degree IP67 according to EN 60529 VAZ-PK-1,5M-V1-G

Other modules
Connection cable piercing method Connection cable module/hand-held pro-
flat cable yellow gramming device
inputs: M12 round connector
Mass 100 g VAZ-FK-ED-G2
Mounting Mounting base AS-Interface end seal for G2 modules

Inductive sensors
Matching system components
U-G3FF
Mounting plate for connection to flat ca-
ble (AS-Interface and external auxiliary
power)
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 167
VAA-4A-G2-E2

AS-Interface actuator module VAA-4A-G2-E2


Dimensions
Masters and
Gateways

118

18.7
Extender, Repeaters
Power Supplies,

4 73.5 34.5
Base is sold separately
Safety at work

36
60
Control cabinet

Electrical connection
I/O Modules

M12x1 quick disconnect


OUT1
AS-Interface - 1
(n.c.)
U® AS-Interface + 4
OUT
2
(n.c.)
Field application

3 Load
I/O Modules

OUT-
5
Order code FG
OUT2
1
VAA-4A-G2-E2 (n.c.)
4
ADDR OUT
G2 flat module 2
(n.c.)
4 electronic outputs (PNP) 3
OUT-
Analogue modules

5
FG
OUT3
PWR 1
(n.c.)
Features FAULT
4
OUT
2
(n.c.)
• AS-Interface certificate 3
OUT-
5
• Protection degree IP67 FG
OUT4
Other modules

• Addressing jack 1
(n.c.)
4
• Flat cable connection with cable OUT
2
(n.c.)
piercing technique, variable flat cable AUX+ 3
AUX- OUT-
guide 5
FG
• Communication monitoring, turn-off
Inductive sensors

• Power supply of outputs from the Functional ground (FG)


external auxiliary voltage Ground connection via mounting base

• Ground connection (PE) possible


Indicating/operating means
• Function display for bus, external
auxiliary voltage and outputs
4
Photoelectric

1 3 4
sensors

5 5
3 2 2 1
OUT1 OUT2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

4 1 3 4
5 5
Rotary encoders

3 2 2 1
OUT3 OUT4

PWR

FAULT
ADDR
AUX
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
168 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface actuator module VAA-4A-G2-E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4A-G2-E2 is an AS-Interface cou-
Slave type Standard slave
pling module with four electronic outputs,
Indicators/operating means which can be loaded to 24 V DC and 1.5 A.
LED FAULT communication error / address is 0; LED red The IP67 flat module features an integrated
LED PWR AS-Interface voltage; LED green addressing jack and is ideal for applications
LED AUX ext. auxiliary voltage UAUX; LED green in the field.

Extender, Repeaters
Power Supplies,
LED OUT switching state (output); 4 LED yellow Connection to the actuators is provided via
Electrical specifications M12 x 1 screw connections. The current
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV switching state of each channel is indicated
Protection class III by an LED, located on the module's top side.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Similarly, an LED is provided to monitor the
Rated operational current Ie ≤ 30 mA AS-Interface communication and to indicate
Output that the module has the address 0. If an AS-

Safety at work
Number/Type 4 electronic outputs, PNP Interface communication error occurs, the
Supply from external auxiliary voltage UAUX outputs are de-energised.
Current 1.5 A pro output, 4 A total The voltages of the AS-Interface and of the
Voltage ≥ (UAUX - 0,5 V) external power supply are also indicated by
Programming instructions an LED each.
Profile S-8.F The U-G3FF mounting base is normally used
IO code 8 for the connection of the AS-Interface flat

Control cabinet
cable and the external 24 V DC power sup-

I/O Modules
ID code F
Data bits (function via AS-Interface) input output ply. The specially designed base enables
D0 IN4 O4 users to connect flat cables from both sides.
D1 - OUT2 This means, for example, that 90° curves can
D2 - OUT3 be laid with very tight radii (variable flat cable
D3 - OUT4 guide).

Field application
Parameter bits (programmable via AS-i) function
Note:

I/O Modules
P0 communication monitoring
P0 = 1 (basic setting), monitoring = ON, i.e. if communication The mounting base for the module is sold
fails, the outputs are de-energised separately.
P0 = 0, monitoring = OFF, if communication fails, the outputs
maintain their condition
P1 not used Accessories
P2 not used

Analogue modules
VBP-HH1
P3 not used
Hand-held programming device
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K) VAZ-PK-1,5M-V1-G
Storage temperature -25 ... 85 °C (248 ... 358 K) Connection cable module/hand-held pro-
Mechanical specifications gramming device
Protection degree IP67 according to EN 60529
Connection cable piercing method VAZ-FK-ED-G2

Other modules
flat cable yellow/flat cable black AS-Interface end seal for G2 modules
inputs/outputs: M12 round connector
Mass 100 g
Mounting Mounting base Matching system components
U-G3FF
Mounting plate for connection to flat ca-

Inductive sensors
ble (AS-Interface and external auxiliary
power)

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 169
VBA-4E3A-G4-ZE/E2

AS-Interface sensor-/actuator module VBA-4E3A-G4-ZE/E2


Dimensions
Masters and
Gateways

31
Extender, Repeaters

90
Power Supplies,

80
66

102

71
Safety at work

Base is sold separately

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

IN1
1.1
I+1
U
®
AS-Interface - 1.2
I1
1.3
I-1
Field application

AS-Interface +
IN2 for 3-wire sensors
I/O Modules

2.1
I+2
Order code 2.2
I2
2.3

Input
I-2
VBA-4E3A-G4-ZE/E2 IN3
3.1
G4 module IP65 I+3
3.2
I3
4 inputs (PNP) and 3 electronic outputs 3.3
Analogue modules

I-3
IN4
4.1
I+4
4.2
I4
PWR/FAULT 4.3
Features I-4

• Protection degree IP65


OUT1
1.2
• A/B slave with extended addressing 1.3
O1
possibility for up to 62 slaves O-1 Load
Other modules

OUT2
Output

• Flat or round cable connection (via 2.2


O2
2.3
standardised EEMS base, not O-2
included in the delivery package) OUT3
3.2
O3
• Cable piercing method for flat cable AUX 3.3
O-3
Inductive sensors

AUX+
• Inputs for 2- and 3-wire sensors
AUX-
• Power supply of outputs from the
external auxiliary voltage
• Power supply of inputs from the Indicating/operating means
module
• Function display for bus, ext. auxiliary
Photoelectric

voltage, inputs and outputs


sensors

• LED indicator for overload on sensor


supply 1 2 3 4 PWR/
inputs FAULT
1 2 3 4 AUX
outputs
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

Terminal block Terminal block


Input Output
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
170 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-4E3A-G4-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E3A-G4-ZE/E2 is an AS-Interface
Slave type A/B slave
coupling module with four inputs and three
Indicators/operating means outputs. Mechanical contacts and 2- and 3-
LED PWR/FAULT dual LED green/red wire sensors can be connected to the inputs.
green: AS-Interface voltage
red: communication error or address 0
The sensors are supplied via the module.
The outputs are electronic outputs, which

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED AUX ext. auxiliary voltage UAUX; LED green can be loaded to 24 V DC and 2 A or 1.5 A
LED IN switching state (input); 4 LED yellow per output (total load < 4 A).
LED OUT switching state (output); 3 LED yellow The G4 module is especially suitable for
Electrical specifications rough conditions. Sensors and actuators
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
attach to cable glands and cage tension
Protection class III
spring terminals thus making the installation
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
especially user-friendly. For pre-addressing

Safety at work
Rated operational current Ie ≤ 60 mA (without sensors) / max. 240 mA
the module it can be plugged directly onto
the adapter of the hand-held programming
Input
device VBP-HH1.
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
The current switching state of each channel
Supply from AS-Interface
is indicated by an LED, located on the mod-
Voltage 21 ... 31 V
ule's top side. In the case of communication
Current loading capacity ≤ 180 mA (TB ≤ 40 °C),
≤ 140 mA (TB ≤ 60 °C), short-circuit proof
errors on the bus, the outputs are de-ener-

Control cabinet
gised via an integrated watchdog.

I/O Modules
Input current ≤ 8 mA (limited internally)
Switching point according to DIN EN 61131-2 (Type 2)
Both flat and round cables can be used for
0 (unattenuated) ≤ 2 mA
the AS-Interface transmission line and the
1 (attenuated) ≥ 4 mA
external 24 V DC power supply. Use the
U-G1FF base for the AS-Interface flat cable.
Output
The AS-Interface standardised EEMS inter-
Number/Type 3 electronic outputs, PNP
face, uses the cable piercing method to con-

Field application
Supply from external auxiliary voltage UAUX
nect both the yellow and black flat cables.

I/O Modules
Current 4 A total
OUT 1, OUT 2: 2 A per output Use the U-G1PP base for the round cable.
OUT 3: 1.5 A The AS-Interface-cable as well as the exter-
Voltage ≥ (UAUX - 0,5 V) nal power supply may be connected within
Programming instructions this base.
Profile S-7.A.0

Analogue modules
IO code 7 Note:
ID code A The device incorporates communication
ID1 code 7 monitoring, which switches off power to the
ID2 code 0 outputs if no communication has taken place
Data bits (function via AS-Interface) input output on the AS-Interface line for longer than
D0 IN1 OUT1 40 ms.
D1 IN2 OUT2 An overloading of the internal input supply or
of the outputs is signalled to the AS-Interface

Other modules
D2 IN3 OUT3
D3 IN4 - master via the "Peripheral fault" function.
Parameter bits (programmable via AS-i) function Communication via the AS-Interface remains
P0 not used intact.
P1 not used
P2 not used Accessories
P3 not used

Inductive sensors
Ambient conditions VBP-HH1
Ambient temperature -25 ... 60 °C (248 ... 333 K) Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)
VAZ-G4-B
Mechanical specifications
Blind plug PG7
Protection degree IP65 according to EN 60529
Connection cable piercing method or terminal compartment
flat cable yellow/flat cable black or standard round cable Matching system components
Photoelectric

inputs/outputs: screwed connection M12 x 1,5 and cage clamp


terminals U-G1FF
sensors

Mass 350 g Base for connection to flat cable (EEMS;


Mounting DIN rail or screw mounting AS-Interface and external auxiliary pow-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

er)
U-G1FFA
Rotary encoders

Base with addressing jack for connection


to flat cable (EEMS; AS-Interface and ex-
ternal auxiliary power)
U-G1PP
Base for connection to round cable
(EEMS;
AS-Interface and external auxiliary volt-
Accessories

age)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 171
VBA-2E2A-G4-ZE/E2

AS-Interface sensor-/actuator module VBA-2E2A-G4-ZE/E2


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

U
®

IN3
Field application

AS-Interface + 1.1
I+3
I/O Modules

1.2
AS-Interface - I3
Order code 1.3
I-3
IN4 for 3-wire sensors
VBA-2E2A-G4-ZE/E2 2.1
I+4
2.2
G4 module IP67 I4
2.3
I-4
2 inputs (PNP) and 2 electronic outputs
Analogue modules

PWR/FAULT OUT1
Features 3.2
O1
3.3
• Protection degree IP67 O-1 Load
OUT2
• A/B slave with extended addressing 4.2
O2
4.3
possibility for up to 62 slaves
Other modules

O-2

• Flat or round cable connection (via


standardised EEMS base, not AUX+
included in the delivery package) AUX-
• Cable piercing method for flat cable
Inductive sensors

• Communication monitoring
• Inputs for 2- and 3-wire sensors
• Power supply of outputs from the
external auxiliary voltage Indicating/operating means
• Supply for inputs from AS-Interface
• Function display for bus, inputs and
Photoelectric

outputs
sensors

• LED indicator for overload on sensor


supply O1 O2 I3 I4 PWR/
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

FAULT
• Detection of output overload OUTPUTS INPUTS
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
172 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VBA-2E2A-G4-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VBA-2E2A-G4-ZE/E2 AS-Interface mod-
Slave type A/B slave
ule is equipped with 2 inputs and 2 outputs.
Indicators/operating means The inputs permit the connection of mechan-
LED PWR/FAULT dual LED green/red ical contacts and of 2- and 3-wire sensors,
green: AS-Interface voltage
red: communication error or address 0
The sensors are supplied via the module.
The outputs are electronic outputs, which

Extender, Repeaters
green/red flashing: overload sensor supply or outputs

Power Supplies,
LED IN switching state (input); 2 LED yellow can be loaded to 24 V DC and 1 A per out-
LED OUT switching state (output); 2 LED yellow put.
Electrical specifications The IP67 rated G4 module is particularly
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
suitable for rough conditions. Sensors and
Protection class III
actuators attach to cable glands and cage
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
tension spring terminals thus making the
Rated operational current Ie ≤ 30 mA (without sensors) / max. 140 mA
installation especially user-friendly. For pre-

Safety at work
addressing the module it can be plugged
Input
directly onto the adapter of the hand-held
Number/Type 2 inputs for 2- or 3-wire sensors (PNP), DC
programming device VBP-HH1.
Supply from AS-Interface
The current switching state of each channel
Voltage 21 ... 31 V
is indicated by an LED, located on the mod-
Current loading capacity ≤ 100 mA (TB ≤ 40 °C),
≤ 75 mA (TB ≤ 60 °C), overload-proof and short-circuit proof
ule's top side. In the case of communication
Input current ≤ 8 mA (limited internally)
errors on the bus, the outputs are de-ener-

Control cabinet
gised via an integrated watchdog.

I/O Modules
Switching point according to DIN EN 61131-2 (Type 2)
0 (unattenuated) ≤ 2 mA
Both flat and round cables can be used for
1 (attenuated) ≥ 4 mA
the connection of the AS-Interface transmis-
sion line and the external 24 V DC power
Output
supply. Use the U-G1FF base for the AS-
Number/Type 2 electronic outputs, PNP
Interface flat cable. The AS-Interface stand-
Supply from external auxiliary voltage UAUX
ardised EEMS interface, uses the cable

Field application
Current 1 A per output
piercing method to connect both the yellow

I/O Modules
Voltage ≥ (UAUX - 0,5 V)
and black flat cables.
Programming instructions
Use the U-G1PP base for a round cable. The
Profile S-B.A.0 AS-Interface-cable as well as the external
IO code B power supply may be connected within the
ID code A U-G1PP base.
ID1 code 7

Analogue modules
ID2 code 0 Note:
Data bits (function via AS-Interface) input output The device incorporates communication
D0 IN4 O4 monitoring, which switches off power to the
D1 - OUT2 outputs if no communication has taken place
D2 IN3 - on the AS-Interface line for longer than
D3 IN4 - 40 ms.
Parameter bits (programmable via AS-i) function An overloading of the internal input supply or

Other modules
P0 not used of the outputs is signalled to the AS-Interface
P1 not used master via the "Peripheral fault" function.
P2 not used Communication via the AS-Interface remains
P3 not used intact.
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Accessories

Inductive sensors
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications VBP-HH1
Protection degree IP67 according to EN 60529 Hand-held programming device
Connection cable piercing method or terminal compartment
flat cable yellow/flat cable black or standard round cable VAZ-G4-B
inputs/outputs: screwed connection M12 x 1,5 and cage clamp Blind plug PG7
terminals
Mass 180 g
Matching system components
Photoelectric

Mounting DIN rail or screw mounting


sensors

U-G1FF
Base for connection to flat cable (EEMS;
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface and external auxiliary pow-


er)
Rotary encoders

U-G1FFA
Base with addressing jack for connection
to flat cable (EEMS; AS-Interface and ex-
ternal auxiliary power)
U-G1PP
Base for connection to round cable
(EEMS;
Accessories

AS-Interface and external auxiliary volt-


age)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 173
VBA-4E-G4-ZE

AS-Interface sensor module VBA-4E-G4-ZE


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

U
®
Field application
I/O Modules

IN1
AS-Interface + 1.1
Order code 1.2
I+1
AS-Interface - I1
1.3
VBA-4E-G4-ZE I-1
IN2 for 3-wire sensors
G4 module IP67 2.1
I+2
2.2
4 inputs (PNP) I2
Analogue modules

2.3
I-2
IN3
3.1
I+3
3.2
I3
Features 3.3
I-3
• Protection degree IP67 IN4
PWR/FAULT 4.1
I+4
4.2
• A/B slave with extended addressing I4
4.4
possibility for up to 62 slaves I-4
Other modules

• Flat or round cable connection (via


standardised EMS base, not included
in the delivery package)
• Cable piercing method for flat cable
Inductive sensors

• Inputs for 2- and 3-wire sensors


• Power supply of inputs from the
module
• Function display for bus and inputs Indicating/operating means
• LED indicator for overload on sensor
supply
Photoelectric
sensors

1 2 3 4 PWR/
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

FAULT
INPUTS
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
174 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VBA-4E-G4-ZE
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E-G4-ZE AS-Interface coupling
Slave type A/B slave
module is a G4 module with 4 inputs.
Indicators/operating means Mechanical contacts and 2- and 3-wire sen-
LED PWR/FAULT dual LED green/red sors can be connected to the inputs. The
green: AS-Interface voltage
red: communication error or address 0
sensors are supplied via the module.
The IP67 rated G4 module is especially suit-

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state (input); 4 LED yellow able for rough conditions. Sensors attach to
Electrical specifications cable glands and cage tension spring termi-
Protection class III
nals thus making the installation especially
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
user-friendly. For pre-addressing the module
Rated operational current Ie ≤ 40 mA (without sensors) / max. 190 mA
it can be plugged directly onto the adapter of
the hand-held programming device
Input
VBP-HH1.
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC

Safety at work
The current switching state of each channel
Supply from AS-Interface
is indicated by an LED, located on the mod-
Voltage 21 ... 31 V
ule's top side.
Current loading capacity ≤ 150 mA (TB ≤ 40 °C),
≤ 120 mA (TB ≤ 60 °C), short-circuit proof
Both flat and round cables can be used for
Input current ≤ 8 mA (limited internally)
the connection of the AS-Interface transmis-
Switching point according to DIN EN 61131-2 (Type 2)
sion line. Use the U-G1F base or the
0 (unattenuated) ≤ 2 mA
U-G1FF base for the AS-Interface flat cable.

Control cabinet
The standardized EMS interface, uses the

I/O Modules
1 (attenuated) ≥ 4 mA
cable piercing method to connect the AS-
Programming instructions
Interface cable. The U-G1F base can also be
Profile S-0.A.0
used as IP67 AS-Interface distribution box.
IO code 0
The U-G1FF base should be used, when
ID code A
modules with outputs are mounted in series
ID1 code 7
with the module. The flat cable for external

Field application
ID2 code 0
power supply can be placed in this base. The

I/O Modules
Data bits (function via AS-Interface) input output
module does not access the supply line.
D0 IN1 -
Use the U-G1P or the U-G1PP base for a
D1 IN2 -
round cable.These bases have the same
D2 IN3 -
functionality as the U-G1F or the U-G1FF
D3 IN4 -
bases.
Parameter bits (programmable via AS-i) function

Analogue modules
P0 not used
Note:
P1 not used
An overloading of the internal input supply is
P2 not used
signalled to the AS-Interface master via the
P3 not used
"Peripheral fault" function. Communication
Ambient conditions
via the AS-Interface remains intact.
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)

Other modules
Mechanical specifications Accessories
Protection degree IP67 according to EN 60529 VBP-HH1
Connection cable piercing method or terminal compartment Hand-held programming device
flat cable yellow or standard round cable
inputs: screwed connection M12 x 1,5 and cage-clamp termi-
nals
VAZ-G4-B
Mass 180 g Blind plug PG7

Inductive sensors
Mounting DIN rail or screw mounting
Matching system components
U-G1F
Base for connection to flat cable (EMS;
AS-Interface only)
U-G1FA
Photoelectric

Base with addressing jack for connection


sensors

to flat cable (EMS; AS-Interface only)


U-G1P
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Base for connection to round cable


(EMS;
Rotary encoders

AS-Interface only)
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 175
VAA-4EA-G4-ZE/E2

AS-Interface sensor-/actuator module VAA-4EA-G4-ZE/E2


Dimensions
Masters and
Gateways

31
Extender, Repeaters

90
Power Supplies,

80
66

102

71
Safety at work

Base is sold separately


Control cabinet

Electrical connection
I/O Modules

IN1
1.1
I+1
1.2
I1
U
®
1.3
I-1
AS-Interface - IN2
Field application

2.1 for 3-wire sensors


I+2
I/O Modules

AS-Interface + 2.2
I2
Order code 2.3

Input
I-2
IN3
VAA-4EA-G4-ZE/E2 3.1
I+3
3.2
G4 module IP65 I3
3.3
I-3
4 inputs (PNP) and 4 electronic outputs
Analogue modules

IN4
4.1
I+4
4.2
I4
4.3
I-4
PWR/FAULT
Features OUT1
1.2
O1
• AS-Interface certificate 1.3
O-1 Load
OUT2
• Protection degree IP65 2.2
O2
Other modules

2.3
Output

• Flat or round cable connection (via O-2


OUT3
standardised EEMS base, not 3.2
O3
included in the delivery package) 3.3
O-3
OUT4
• Cable piercing method for flat cable 4.2
O4
4.3
• Communication monitoring, turn-off O-4
Inductive sensors

AUX+
• Inputs for 2- and 3-wire sensors AUX-

• Power supply of outputs from the


external auxiliary voltage
Indicating/operating means
• Power supply of inputs from the
module
• Function display for bus, ext. auxiliary
Photoelectric

voltage, inputs and outputs


sensors

• Monitoring of sensor overloads


1 2 3 4 PWR/ 1 2 3 4 AE
outputs
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

inputs FAULT
1 2 3 4 1 2 3 4
Rotary encoders

Terminal block Terminal block


Input Output
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
176 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-G4-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-G4-ZE/E2 is an AS-Interface
Slave type Standard slave
coupling module with four inputs and four
Indicators/operating means outputs. Mechanical contacts and 2- and 3-
LED PWR/FAULT dual LED green/red wire sensors can be connected to the inputs.
green: AS-Interface voltage
red: communication error or address 0
The sensors are supplied via the module.
The outputs are electronic outputs, which

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state (input); 4 LED yellow can be loaded to 24 V DC and 2 A per output
LED OUT switching state (output); 4 LED yellow (total load < 4 A).
LED AE ext. auxiliary voltage UAUX; LED green The G4 module is especially suitable for
Electrical specifications rough conditions. Sensors and actuators
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
attach to cable glands and cage tension
Protection class III
spring terminals thus making the installation
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
especially user-friendly. For pre-addressing

Safety at work
Rated operational current Ie ≤ 60 mA (without sensors) / max. 240 mA
the module it can be plugged directly onto
the adapter of the hand-held programming
Input
device VBP-HH1.
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC
The current switching state of each channel
Supply from AS-Interface
is indicated by an LED, located on the mod-
Voltage 21 ... 31 V
ule's top side. In the case of communication
Current loading capacity ≤ 180 mA (TB ≤ 40 °C),
≤ 140 mA (TB ≤ 60 °C), short-circuit proof
errors on the bus, the outputs are de-ener-

Control cabinet
gised via an integrated watchdog, which can

I/O Modules
Input current ≤ 8 mA (limited internally)
Switching point
be deactivated by the parameter bit P0.
0 (unattenuated) ≤ 1.5 mA
Both flat and round cables can be used for
1 (attenuated) ≥ 4.5 mA
the AS-Interface transmission line and the
external 24 V DC power supply. Use the
Output
U-G1FF base for the AS-Interface flat cable.
Number/Type 4 electronic outputs, PNP
The AS-Interface standardised EEMS inter-

Field application
Supply from external auxiliary voltage UAUX
face, uses the cable piercing method to con-

I/O Modules
Current 2 A per output, 4 A total
nect both the yellow and black flat cables.
Voltage ≥ (UAUX - 0,5 V)
Use the U-G1PP base for the round cable.
Programming instructions
The AS-Interface cable as well as the exter-
Profile S-7.F nal power supply may be connected within
IO code 7 this base.
ID code F

Analogue modules
Data bits (function via AS-Interface) input output
D0 IN1 OUT1 Accessories
D1 IN2 OUT2
VBP-HH1
D2 IN3 OUT3
Hand-held programming device
D3 IN4 OUT4
Parameter bits (programmable via AS-i) function VAZ-G4-B
P0 communication monitoring Blind plug PG7

Other modules
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs Matching system components
maintain their condition
P1 not used U-G1FF
P2 not used Base for connection to flat cable (EEMS;
P3 not used AS-Interface and external auxiliary pow-

Inductive sensors
Ambient conditions er)
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) U-G1FFA
Mechanical specifications Base with addressing jack for connection
Protection degree IP65 according to EN 60529 to flat cable (EEMS; AS-Interface and ex-
Connection cable piercing method or terminal compartment ternal auxiliary power)
flat cable yellow/flat cable black or standard round cable
inputs/outputs: screwed connection M12 x 1,5 and cage clamp U-G1PP
Photoelectric

terminals Base for connection to round cable


sensors

Mass 350 g
(EEMS;
Mounting DIN rail or screw mounting
AS-Interface and external auxiliary volt-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

age)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 177
VAA-2EA-G4-ZE/E2

AS-Interface sensor-/actuator module VAA-2EA-G4-ZE/E2


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately


Control cabinet

Electrical connection
I/O Modules

U
®

IN1
Field application

AS-Interface - Sensor + 1.1


I+1
I/O Modules

AS-Interface + 1.2
I1
Order code 1.3
I-1
VAA-2EA-G4-ZE/E2 IN2 for 3-wire sensors
2.1
I+1
2.2
G4 module IP67 I1
2.3
2 inputs (PNP) and 2 electronic outputs I-1
Sensor -
Analogue modules

3.2 OUT3
Features PWR Load
3.3 OUT-
• AS-Interface certificate 4.2 OUT4
• Protection degree IP67 4.3 OUT-
Other modules

• Flat or round cable connection (via


standardised EEMS base, not
included in the delivery package) for AUX+
connection
AUX-
• Cable piercing method for flat cable of UAUX

• Communication monitoring, turn-off


Inductive sensors

• Inputs for 2- and 3-wire sensors


• Power supply of outputs from the
external auxiliary voltage
Indicating/operating means
• Power supply of inputs from the
module
• Function display for bus and inputs
Photoelectric
sensors

• Monitoring of sensor overloads

1 2 3 4 Pwr
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

inputs outputs
1 2 3 4
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
178 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-2EA-G4-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-2EA-G4-ZE/E2 is an AS-Interface
Slave type Standard slave
coupling module with two inputs and two out-
Indicators/operating means puts. Mechanical contacts and 2- and 3-wire
LED PWR dual LED green/red sensors can be connected to the inputs.The
green: AS-Interface voltage
red: communication error or address 0
sensors are supplied via the module. The
outputs are electronic outputs, which can be

Extender, Repeaters
green/red flashing: overload sensor supply

Power Supplies,
LED IN switching state (input); 2 LED yellow loaded to 24 V DC and 1.5 A per output (total
LED OUT switching state (output); 2 LED yellow load < 4 A).
Electrical specifications The G4 module in IP67 is especially suitable
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
for rough conditions. The connection to sen-
Protection class III
sors and actuators is established via cable
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
glands and cage tension spring terminals
Rated operational current Ie ≤ 60 mA (without sensors) / max. 240 mA
thus making the installation especially user-

Safety at work
friendly. For pre-addressing the module, it
Input
can be directly plugged onto the adapter of
Number/Type 2 inputs for 2- or 3-wire sensors (PNP), DC
the VBP-HH1 handheld programming device.
Supply from AS-Interface
An LED is provided for each channel, on the
Voltage 21 ... 31 V
top of the module, to indicate the current
Current loading capacity ≤ 180 mA (TB ≤ 40 °C),
≤ 140 mA (TB ≤ 60 °C), short-circuit proof
switching status. In the case of communica-
Input current ≤ 8 mA (limited internally)
tion errors on the bus, the outputs are de-

Control cabinet
energised via an integrated watchdog, which

I/O Modules
Switching point
0 (unattenuated) ≤ 1.5 mA
can be disabled by the P0 parameter bit.
1 (attenuated) ≥ 4.5 mA
The AS-Interface transmission cable and the
external 24 V DC supply can be connected
Output
through flat cables or round cables. Use the
Number/Type 2 electronic outputs, PNP
U-G1FF for the AS-Interface flat cable. The
Supply from external auxiliary voltage UAUX
connection to both cables is established

Field application
Current 1.5 A per output
using the AS-Interface standardised EEMS

I/O Modules
Voltage ≥ (UAUX - 0,5 V)
interface, i. e. the cable piercing method.
Programming instructions
Use the U-G1PP base for a round cable. The
Profile S-3.F U-G1PP base allows the AS-Interface-cable
IO code 3 as well as the external power supply to be
ID code F connected.
Data bits (function via AS-Interface) input output

Analogue modules
D0 IN1 -
D1 IN2 - Accessories
D2 - OUT3
VBP-HH1
D3 - OUT4
Hand-held programming device
Parameter bits (programmable via AS-i) function
P0 communication monitoring VAZ-G4-B
P0 = 1 (basic setting), monitoring = ON, i.e. if communication
Blind plug PG7

Other modules
fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs
maintain their condition
Matching system components
P1 not used
P2 not used U-G1FF
P3 not used Base for connection to flat cable (EEMS;
Ambient conditions AS-Interface and external auxiliary pow-

Inductive sensors
Ambient temperature -25 ... 60 °C (248 ... 333 K) er)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications U-G1FFA
Protection degree IP67 according to EN 60529 Base with addressing jack for connection
Connection cable piercing method or terminal compartment to flat cable (EEMS; AS-Interface and ex-
flat cable yellow/flat cable black or standard round cable ternal auxiliary power)
inputs/outputs: screwed connection M12 x 1,5 and cage clamp
terminals U-G1PP
Photoelectric

Mass 180 g Base for connection to round cable


sensors

Mounting DIN rail or screw mounting


(EEMS;
AS-Interface and external auxiliary volt-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

age)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 179
VAA-4E-G4-Z

AS-Interface sensor module VAA-4E-G4-Z


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately


Control cabinet

Electrical connection
I/O Modules

U
®
Field application
I/O Modules

AS-Interface +
1.1
Order code AS-Interface - IN1+
1.2
IN1-
VAA-4E-G4-Z
2.1
IN2+
G4 module IP67 2.2
IN2-
4 inputs (2-wire )
Analogue modules

3.1
IN3+
3.2
IN3-
4.1
Features IN4+
4.2
IN4-
• AS-Interface certificate
• Protection degree IP67
Other modules

• Flat or round cable connection (via


standardised EMS base, not included
in the delivery package) PWR
• Inputs for 2-wire sensors
• Function display for bus and inputs
Inductive sensors

• Lead monitoring of inputs that can be


switched off selectively by channel

Indicating/operating means
Photoelectric
sensors

1 2 3 4 PWR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

INPUTS
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
180 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VAA-4E-G4-Z
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E-G4-Z AS-Interface coupling
Slave type Standard slave
module is a field module with 4 inputs. The
Indicators/operating means inputs permit the connection of 2-wire sen-
LED PWR AS-Interface voltage; LED green sors, which can be monitored for lead break-
LED IN 4 dual LED yellow/red age and short circuit (see note).
yellow: switching state (input)
The IP67 rated G4 module is especially suit-

Extender, Repeaters
red: lead breakage

Power Supplies,
red and yellow: line short-circuit able for rough conditions. Sensors attach to
Electrical specifications cable glands and cage tension spring termi-
Protection class III
nals. For pre-addressing the module it can
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
be plugged directly onto the adapter of the
Rated operational current Ie ≤ 40 mA
hand-held programming device VBP-HH1.
Both flat and round cables can be used for
Input
the connection of the AS-Interface cable.Use
Number/Type 4 inputs for 2-wire sensors, DC

Safety at work
the U-G1F or U-G1FF base for flat cables.
Supply from AS-Interface
The connection to the AS-Interface cable is
Voltage 15 V
established via the standardised EMS inter-
Input current ≤ 8 mA (limited internally)
face (cable piercing method). The U-G1F
Switching point
base can also be used as IP67 AS-Interface
0 (unattenuated) ≤ 1.5 mA
distribution box. Use the U-G1FF base, when
1 (attenuated) ≥ 4.5 mA
modules with outputs are mounted in series
lead breakage: ≤ 0.5 mA

Control cabinet
Lead monitoring
with the module. The flat cable for external

I/O Modules
lead short-circuit: ≥ 5 mA
power supply can be placed in this base
Programming instructions
since the module does not access the supply
Profile S-0.F
line.
IO code 0
Use the U-G1P or the U-G1PP base for a
ID code F
round cable. These bases have the same
Data bits (function via AS-Interface) input output
functionality as the U-G1F or the U-G1FF

Field application
D0 IN1 -
bases.

I/O Modules
D1 IN2 -
D2 IN3 -
Note:
D3 IN4 -
Lead breakage/short circuit monitoring is
Parameter bits (programmable via AS-i) function
activated or deactivated per channel, by
P0 lead monitoring IN1
P0 = 1 (basic setting), monitoring deactivated means of the parameter bits P0 ... P3. All

Analogue modules
P0 = 0, monitoring activated error conditions are linked by an OR-logic-
P1 lead monitoring IN2 operation. In a failure case, the AS-Interface
P1 = 1 (basic setting), monitoring deactivated master indicates an error and the module
P1 = 0, monitoring activated disconnects from the AS-Interface, while the
P2 lead monitoring IN3 monitoring function is activated.
P2 = 1 (basic setting), monitoring deactivated
P2 = 0, monitoring activated
P3 lead monitoring IN4 Accessories
P3 = 1 (basic setting), monitoring deactivated

Other modules
P3 = 0, monitoring activated VBP-HH1
Ambient conditions Hand-held programming device
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) VAZ-G4-B
Mechanical specifications Blind plug PG7
Protection degree IP67 according to EN 60529

Inductive sensors
Connection cable piercing method or terminal compartment Matching system components
flat cable yellow or standard round cable
inputs: screwed connection M12 x 1,5 and cage-clamp termi- U-G1F
nals Base for connection to flat cable (EMS;
Mass 180 g
AS-Interface only)
Mounting DIN rail or screw mounting
U-G1FA
Base with addressing jack for connection
Photoelectric

to flat cable (EMS; AS-Interface only)


sensors

U-G1P
Base for connection to round cable
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

(EMS;
AS-Interface only)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 181
VAA-4E-G4-N

AS-Interface sensor module VAA-4E-G4-N


Dimensions
Masters and
Gateways

31
Extender, Repeaters

45
Power Supplies,

80
66

102

51
Safety at work

Base is sold separately


Control cabinet

Electrical connection
I/O Modules

U
®
Field application
I/O Modules

AS-Interface +
1.1
Order code AS-Interface - IN1+
1.2
IN1-
VAA-4E-G4-N
2.1
IN2+
G4 module IP67 2.2
IN2-
4 inputs (NAMUR)
Analogue modules

3.1
IN3+
3.2
IN3-
4.1
Features IN4+
4.2
IN4-
• AS-Interface certificate
• Protection degree IP67
Other modules

• Flat or round cable connection (via


standardised EMS base, not included
in the delivery package) PWR
• Cable piercing method for flat cable
• Inputs in accordance with IEC 60947-
Inductive sensors

5-6 (NAMUR, DIN 19234)


• Function display for bus and inputs
• Lead monitoring of inputs that can be
switched off selectively by channel Indicating/operating means
Photoelectric
sensors

1 2 3 4 PWR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

INPUTS
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
182 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VAA-4E-G4-N
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E-G4-N is an AS-Interface cou-
Slave type Standard slave
pling module with 4 inputs for sensors per
Indicators/operating means DIN 19234 (NAMUR), which can be moni-
LED PWR AS-Interface voltage; LED green tored for lead breakage and short circuit (see
LED IN 4 dual LED yellow/red note).
yellow: switching state (input)
The IP67 rated G4 module is especially suit-

Extender, Repeaters
red: lead breakage

Power Supplies,
red and yellow: line short-circuit able for rough conditions. Sensors attach to
Electrical specifications cable glands and cage tension spring termi-
Protection class III
nals. For pre-addressing the module it can
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
be plugged directly onto the adapter of the
Rated operational current Ie ≤ 40 mA
hand-held programming device VBP-HH1.
Both flat and round cables can be used for
Input
the connection of the AS-Interface transmis-
Number/Type 4 Inputs for NAMUR sensors

Safety at work
sion line. Use the U-G1F or U-G1FF base for
Supply from AS-Interface
AS-Interface flat cables. The connection to
Voltage 8V
the AS-Interface cable is established via the
Switching point OUT ≥ 1.8 mA
ON ≤ 1.5 mA
standardised EMS interface (cable piercing
Lead monitoring lead breakage: ≤ 0.15 mA
method). The U-G1F base can also be used
lead short-circuit: ≥ 6 mA as IP67 AS-Interface distribution box. Use
Programming instructions the U-G1FF base, when modules with out-

Control cabinet
puts are mounted in series with the module.

I/O Modules
Profile S-0.F
IO code 0 The flat cable for external power supply can
ID code F be placed in this base, since the module
Data bits (function via AS-Interface) input output does not access the supply line.
D0 IN1 - Use the U-G1P or U-G1PP base for round
D1 IN2 - cables. These bases have the same func-
tionality as the U-G1F or the U-G1FF bases.

Field application
D2 IN3 -

I/O Modules
D3 IN4 -
Parameter bits (programmable via AS-i) function Note:
P0 lead monitoring IN1 Lead breakage/short circuit monitoring is
P0 = 1 (basic setting), monitoring deactivated activated or deactivated per channel, by
P0 = 0, monitoring activated means of the parameter bits P0 ... P3. All
P1 lead monitoring IN2 error conditions are linked by an OR-logic-

Analogue modules
P1 = 1 (basic setting), monitoring deactivated operation. In a failure case, the AS-Interface
P1 = 0, monitoring activated
master indicates an error and the module
P2 lead monitoring IN3
P2 = 1 (basic setting), monitoring deactivated disconnects from the AS-Interface, while the
P2 = 0, monitoring activated watchdog is activated.
P3 lead monitoring IN4
P3 = 1 (basic setting), monitoring deactivated
P3 = 0, monitoring activated Accessories
Ambient conditions VBP-HH1

Other modules
Ambient temperature -25 ... 60 °C (248 ... 333 K) Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications VAZ-G4-B
Protection degree IP67 according to EN 60529 Blind plug PG7
Connection cable piercing method or terminal compartment
flat cable yellow or standard round cable
Matching system components

Inductive sensors
inputs: screwed connection M12 x 1,5 and cage-clamp termi-
nals
U-G1F
Mass 180 g
Base for connection to flat cable (EMS;
Mounting DIN rail or screw mounting
AS-Interface only)
U-G1FA
Base with addressing jack for connection
to flat cable (EMS; AS-Interface only)
Photoelectric
sensors

U-G1P
Base for connection to round cable
(EMS;
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface only)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 183
VAA-4EA-G6-ZE/E2

AS-Interface sensor-/actuator module VAA-4EA-G6-ZE/E2


Dimensions
Masters and
Gateways

138.7

ø4.5
26
Extender, Repeaters
Power Supplies,

129

ø4.5
26
Safety at work

129
Control cabinet

Electrical connection
I/O Modules

U
® M8x1 quick disconnect
M12x1 4 inputs I-1 ... I-4
Field application

quick disconnect Sensor + 1


IN+
I/O Modules

BUS IN
1 AS-Interface +
Order code 4
IN
VAA-4EA-G6-ZE/E2
Sensor - 3 IN-
G6 compact module
3 AS-Interface -
4 inputs (PNP) and 4 electronic outputs
Analogue modules

for 3-wire
sensors

M8x1 quick disconnect


Features 4 outputs O-1 ... O-4
• AS-Interface certificate 1 common connection
of all 4 outputs
• Compact design, can be mounted in
any position 4
Other modules

AS-Interface OUT
• Protection degree IP67 Load
3
OUT-
• Connections via round connector 4 AUX +

2 AUX -
• Communication monitoring
• Inputs for 2- and 3-wire sensors
Inductive sensors

• Power supply of outputs from the


external auxiliary voltage
• Power supply of inputs from the Indicating/operating means
module
• Function display for bus, ext. auxiliary
voltage, inputs and outputs
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

UAUX
I-1 I-2 I-3 I-4 O-1 O-2 O-3 O-4
1
Rotary encoders

4 4 4 4 4 4 4 4 2 4
3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3

BUS IN
ASI
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
184 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4EA-G6-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-G6-ZE/E2 is an AS-Interface
Slave type Standard slave
compact module with 4 inputs and 4 outputs.
Indicators/operating means Mechanical contacts and 2- and 3-wire sen-
LED UAUX ext. auxiliary voltage UAUX; LED green sors can be connected to the inputs. The out-
LED AS-i AS-Interface voltage; LED green puts are sourcing electronic outputs, which
LED IN switching state (input); 4 LED yellow can be loaded to 24 V DC and 0.5 A per out-

Extender, Repeaters
Power Supplies,
LED OUT switching state (output); 4 LED yellow put.
Electrical specifications Its particularly flat and narrow design makes
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV the IP67 compact module particularly suita-
Protection class III ble for applications in handling machines,
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface robots etc. To achieve the IP67 protection
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA class, it features completely encapsulated
Input electronics. This module has the further

Safety at work
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC advantage that it can be mounted in any
Supply from AS-Interface position.
Voltage 21 ... 31 V The connection to the AS-Interface cable and
Current loading capacity ≤ 200 mA (TB ≤ 40 °C), the external power supply is established via
≤ 150 mA (TB ≤ 60 °C), short-circuit protected an M12 x 1 quick disconnect. Please refer to
Input current ≤ 8 mA (limited internally) the technical data for the pin assignments.
Switching point An advantage of this connection is that a

Control cabinet
0 (unattenuated) ≤ 1.5 mA separate base is not required. A standard

I/O Modules
1 (attenuated) ≥ 4.5 mA cable with M12 x 1 quick disconnects can
Output also be used for addressing.
Number/Type 4 electronic outputs, PNP The sensors/actuators are connected via
Supply from external auxiliary voltage UAUX M8 x 1 quick disconnects. The current
Current 0.5 A per output, 2 A total (TB ≤ 40 °C), switching state of each channel is indicated
0.4 A per output, 1.6 A total (TB ≤ 60 °C) by an LED, located on the module's top side.

Field application
Voltage ≥ (UAUX - 0,5 V) The voltages of the AS-Interface and of the

I/O Modules
Programming instructions external power supply are also indicated by
Profile S-7.0 an LED each.
IO code 7 The outputs are de-energised (watchdog),
ID code 0 whenever communication on the AS-Inter-
Data bits (function via AS-Interface) input output face cable is interrupted.

Analogue modules
D0 IN1 OUT1
D1 IN2 OUT2
Accessories
D2 IN3 OUT3
D3 IN4 OUT4 VBP-HH1
Parameter bits (programmable via AS-i) function Hand-held programming device
P0 not used
P1 not used VAZ-2T5-G2
P2 not used Splitter box AS-Interface and auxiliary

Other modules
P3 not used voltage to 5 x M12 round connector
Ambient conditions
VAZ-2T1-FK-1M-PUR-V1-W
Ambient temperature -20 ... 60 °C (253 ... 333 K)
Storage temperature -20 ... 85 °C (253 ... 358 K)
Splitter box AS-Interface and auxiliary
Mechanical specifications
voltage to 1 x M12 round connector
Protection degree IP67 according to EN 60529

Inductive sensors
Connection AS-Interface and auxiliary voltage: M12 x 1 round connector
sensors/actuators: M8 x 1 round connector
Mounting screw mounting
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 185
VAA-2EA-G6-ZE/E2

AS-Interface sensor-/actuator module VAA-2EA-G6-ZE/E2


Dimensions
Masters and
Gateways

88.5

ø4.5
26
Extender, Repeaters
Power Supplies,

79.5

ø4.5
26
Safety at work

79.5
Control cabinet

Electrical connection
I/O Modules

U
® M8x1 quick disconnect
M12x1 2 inputs I-1 and I-2
Field application

quick disconnect Sensor + 1


IN+
I/O Modules

BUS IN
1 AS-Interface+
Order code 4
IN
VAA-2EA-G6-ZE/E2
Sensor - 3
G6 compact module IN-
3 AS-Interface-
2 inputs (PNP) and 2 electronic outputs
Analogue modules

for 3-wire
sensors

Features M8x1 quick disconnect


2 outputs O-1 and O-2
• AS-Interface certificate AS-Interface 1 common connection
of all 4 outputs
• Compact design, can be mounted in
any position 4
Other modules

OUT
• Protection degree IP67 Load
3
OUT-
• Connections via round connector 4 AUX+

• Inputs for 2- and 3-wire sensors 2 AUX-

• Power supply of outputs from the


Inductive sensors

external auxiliary voltage


• Power supply of inputs from the
module
Indicating/operating means
• Function display for bus, ext. auxiliary
voltage, inputs and outputs
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

UAUX
I-1 I-2 O-1 O-2
Rotary encoders

4 4 4 4 1
2 4
3 1 3 1 3 1 3 1 3

BUS IN
ASI
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
186 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-2EA-G6-ZE/E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-2EA-G6-ZE/E2 is an AS-Interface
Slave type Standard slave
compact module with 2 inputs and 2 outputs.
Indicators/operating means Mechanical contacts and 2- and 3-wire sen-
LED UAUX ext. auxiliary voltage UAUX; LED green sors can be connected to the inputs. Sourc-
LED AS-i AS-Interface voltage; LED green ing outputs can be loaded to 24 V DC and
LED IN switching state (input); 2 LED yellow 0.5 A per output.

Extender, Repeaters
Power Supplies,
LED OUT switching state (output); 2 LED yellow Its particularly flat and narrow design makes
Electrical specifications the IP67 compact module particularly suita-
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV ble for applications in handling machines,
Protection class III robots etc. To achieve this protection class, it
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface features completely encapsulated electron-
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA ics. This module has the further advantage
Input that it may be mounted in any position.

Safety at work
Number/Type 2 inputs for 2- or 3-wire sensors (PNP), DC The connection to the AS-Interface cable and
Supply from AS-Interface the external power supply is established via
Voltage 21 ... 31 V an M12 x 1 quick disconnect. Please refer to
Current loading capacity ≤ 200 mA (TB ≤ 40 °C), the technical data for the pin-assignments.
≤ 150 mA (TB ≤ 60 °C), short-circuit protected An advantage of the connection is that a sep-
Input current ≤ 8 mA (limited internally) arate base is not required. Address configu-
Switching point ration can also be carried out using a

Control cabinet
0 (unattenuated) ≤ 1.5 mA standard cable with M12 x 1 quick discon-

I/O Modules
1 (attenuated) ≥ 4.5 mA nects.
Output The connection to the sensors/actuators is
Number/Type 2 electronic outputs, PNP established via M8 x 1 quick disconnects. An
Supply from external auxiliary voltage UAUX LED is provided for each channel, on the top
Current 0.5 A per output, 1 A total (TB ≤ 40 °C), of the module, to indicate the current switch-
0.4 A per output, 0.8 A total (TB ≤ 60 °C) ing status. The voltages of the AS-Interface

Field application
Voltage ≥ (UAUX - 0,5 V) and of the external power supply are also

I/O Modules
Programming instructions indicated by an LED each.
Profile S-3.0
IO code 3
Accessories
ID code 0
Data bits (function via AS-Interface) input output VBP-HH1

Analogue modules
D0 IN1 - Hand-held programming device
D1 IN2 -
D2 IN4 O4 VAZ-2T5-G2
D3 - OUT2 Splitter box AS-Interface and auxiliary
Parameter bits (programmable via AS-i) function voltage to 5 x M12 round connector
P0 not used
P1 not used VAZ-2T1-FK-1M-PUR-V1-W
P2 not used Splitter box AS-Interface and auxiliary

Other modules
P3 not used voltage to 1 x M12 round connector
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K)
Storage temperature -20 ... 85 °C (253 ... 358 K)
Mechanical specifications
Protection degree IP67 according to EN 60529

Inductive sensors
Connection AS-Interface and auxiliary voltage: M12 x 1 round connector
sensors/actuators: M8 x 1 round connector
Mounting screw mounting
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 187
VAA-4E-G6-ZE

AS-Interface sensor module VAA-4E-G6-ZE


Dimensions
Masters and
Gateways

88.5

ø4.5
26
Extender, Repeaters
Power Supplies,

79.5

ø4.5
26
Safety at work

79.5
Control cabinet

Electrical connection
I/O Modules

U
® M8x1 quick disconnect
M12x1 4 inputs I-1 ... I-4
Field application

quick disconnect Sensor + 1


IN+
I/O Modules

BUS IN
1 AS-Interface+
Order code 4
IN
VAA-4E-G6-ZE 3 AS-Interface-
Sensor - 3
G6 compact module IN-
4 inputs (PNP)
Analogue modules

for 3-wire
sensors

Features
• AS-Interface certificate
• Compact design, can be mounted in
any position
Other modules

• Protection degree IP67


• Connections via round connector AS-Interface

• Inputs for 2- and 3-wire sensors


• Power supply of inputs from the
Inductive sensors

module
• Function display for bus and inputs

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

I-1 I-2 I-3 I-4


Rotary encoders

4 4 4 4 1
2 4
3 1 3 1 3 1 3 1 3

BUS IN
ASI
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
188 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor module VAA-4E-G6-ZE
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E-G6-ZE is an AS-Interface com-
Slave type Standard slave
pact module with 4 inputs. Mechanical con-
Indicators/operating means tacts and 2- and 3-wire sensors can be
LED AS-i AS-Interface voltage; LED green connected to the inputs.
LED IN switching state (input); 4 LED yellow Its particularly flat and narrow design makes
Electrical specifications the IP67 compact module especially suitable

Extender, Repeaters
Power Supplies,
Protection class III for applications in handling machines, robots
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface etc. To achieve this protection class, it fea-
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA tures completely encapsulated electronics.
Input The module has the further advantage that it
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC can be mounted in any position.
Supply from AS-Interface The connection to the AS-Interface cable is
Voltage 21 ... 31 V established via an M12 x 1 quick disconnect.

Safety at work
Current loading capacity ≤ 200 mA (TB ≤ 40 °C), Please refer to the technical data for the pin
≤ 150 mA (TB ≤ 60 °C), short-circuit protected assignments. An advantage of this connec-
Input current ≤ 8 mA (limited internally) tion is that a separate base is not required.
Switching point Address configuration may also be carried
0 (unattenuated) ≤ 1.5 mA out using a standard cable with M12 x 1
1 (attenuated) ≥ 4.5 mA quick disconnects.
Programming instructions Sensors attach to M8 x 1 quick disconnects.

Control cabinet
The current switching state of each channel

I/O Modules
Profile S-0.0
IO code 0 is indicated by an LED, located on the mod-
ID code 0 ule's top side. The voltages of the AS-Inter-
Data bits (function via AS-Interface) input output face and of the external power supply are
D0 IN1 - also indicated by an LED each.
D1 IN2 -
D2 IN3 -

Field application
Accessories

I/O Modules
D3 IN4 -
Parameter bits (programmable via AS-i) function VBP-HH1
P0 not used Hand-held programming device
P1 not used
P2 not used VAZ-2T5-G2
P3 not used Splitter box AS-Interface and auxiliary

Analogue modules
Ambient conditions voltage to 5 x M12 round connector
Ambient temperature -20 ... 60 °C (253 ... 333 K)
VAZ-2T1-FK-1M-PUR-V1-W
Storage temperature -20 ... 85 °C (253 ... 358 K)
Splitter box AS-Interface and auxiliary
Mechanical specifications
voltage to 1 x M12 round connector
Protection degree IP67 according to EN 60529
Connection AS-Interface: M12 x 1 round connector
sensors: M8 x 1 round connector

Other modules
Mounting screw mounting

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 189
VAA-4A-G6-E2

AS-Interface actuator module VAA-4A-G6-E2


Dimensions
Masters and
Gateways

88.5

ø4.5
26
Extender, Repeaters
Power Supplies,

79.5

ø4.5
26
Safety at work

79.5
Control cabinet

Electrical connection
I/O Modules

U
®
M12x1
Field application

quick disconnect
I/O Modules

BUS IN
1 AS-Interface+
Order code
VAA-4A-G6-E2
G6 compact module 3 AS-Interface-
4 electronic outputs
Analogue modules

M8x1 quick disconnect


Features 4 outputs O-1 ... O-4
• AS-Interface certificate 1 common connection
AS-Interface of all 4 outputs
• Compact design, can be mounted in
4
any position OUT
Other modules

Load
• Protection degree IP67 3
OUT-
4 AUX+
• Connections via round connector
2 AUX-
• Power supply of outputs from the
external auxiliary voltage
Inductive sensors

• Function display for bus, external


auxiliary voltage and outputs

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

UAUX
O-1 O-2 O-3 O-4
Rotary encoders

4 4 4 4 1
2 4
3 1 3 1 3 1 3 1 3

BUS IN
ASI
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
190 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface actuator module VAA-4A-G6-E2
Technical data Function

Masters and
General specifications

Gateways
The VAA-4A-G6-E2 is an AS-Interface com-
Slave type Standard slave
pact module with 4 current sourcing outputs.
Indicators/operating means Each output can be loaded to 24 V DC and
LED UAUX ext. auxiliary voltage UAUX; LED green 0.5 A.
LED AS-i AS-Interface voltage; LED green Its particularly flat and narrow design makes
LED OUT switching state (output); 4 LED yellow the IP67 compact module particularly suita-

Extender, Repeaters
Power Supplies,
Electrical specifications ble for applications in handling machines,
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV robots etc. To achieve this protection class,
Protection class III the entire electronics were encapsulated.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface This module has the further advantage that it
Rated operational current Ie ≤ 40 mA may be mounted in any position.
Output The connection to the AS-interface cable is
Number/Type 4 electronic outputs, PNP established via an M12 x 1 quick disconnect.

Safety at work
Supply from external auxiliary voltage UAUX Please refer to the technical data for the pin-
Current 0.5 A per output, 2 A total (TB ≤ 40 °C), assignments. An advantage of this connec-
0.4 A per output, 1.6 A total (TB ≤ 60 °C) tion is that it does not require a separate
Voltage ≥ (UAUX - 0,5 V) base. Address configuration can also be car-
Programming instructions ried out using a standard cable with M12 x 1
Profile S-8.0 screw connections.
IO code 8 Connection to the actuators is provided via

Control cabinet
M8 x 1 screw connections. The current

I/O Modules
ID code 0
Data bits (function via AS-Interface) input output switching state of each channel is indicated
D0 IN4 O4 by an LED. The LEDs are well visible on the
D1 - OUT2 module's top side. The voltages of the AS-
D2 - OUT3 Interface and of the external power supply
D3 - OUT4 are also indicated by an LED each.
Parameter bits (programmable via AS-i) function

Field application
I/O Modules
P0 not used
Accessories
P1 not used
P2 not used VBP-HH1
P3 not used Hand-held programming device
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K)
VAZ-2T5-G2

Analogue modules
Storage temperature -20 ... 85 °C (253 ... 358 K) Splitter box AS-Interface and auxiliary
Mechanical specifications voltage to 5 x M12 round connector
Protection degree IP67 according to EN 60529 VAZ-2T1-FK-1M-PUR-V1-W
Connection AS-Interface and auxiliary voltage: M12 x 1 round connector
actuators: M8 x 1 round connector
Splitter box AS-Interface and auxiliary
Mounting screw mounting voltage to 1 x M12 round connector

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 191
AS-Interface - Analogue modules
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
192 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Analogue modules
5.3 Analogue modules

Masters and
Gateways
Using the new specification 2.1, Profile S7.3 now allows analogue values to
be transmitted just as simply and securely as binary signals without special
programming in the PLC. In max. 35 ms, analogue values for pressure, tem-
perature, fill levels, or anything, are available to the PLC with 16-bit resolu-

Extender, Repeaters
tion via AS-Interface. Analogue output signals have a maximum resolution

Power Supplies,
of 13 bits. The master automatically detects analogue modules and takes
over data conversion via "plug and play", without needing any configuration.
The field modules are housed in the G4 housings described earlier and are
available in these versions:
• Analogue module with 2 inputs for 0 ... 10 V,

Safety at work
• Analogue module with 2 outputs for 0 ... 10 V,
• Analogue module with 2 inputs for 0/4 ... 20 mA,
• Analogue module with 2 outputs for 0/4 ... 20 mA,

Control cabinet
• Analogue module with 4 outputs for connection of a PT100 sensor

I/O Modules
Analogue values are galvanically isolated from the AS-Interface and ana-
logue modules can be supplied with power from the AS-Interface or exter-
nally (configured by jumper). The modules include a display for bus commu-
nication, external auxiliary power, and the inputs/outputs.

Field application
I/O Modules
For the switch cabinet there is a universal analogue module with inputs for
current and voltage (switchable) in a KE2 housing.
A module with the same design enables the connection of 4 inputs for
PT100 sensors.

Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 193
VBA-4E-G4-Pt100

AS-Interface analogue module VBA-4E-G4-Pt100


Dimensions
Masters and
Gateways

31
Extender, Repeaters

90
Power Supplies,

80
66

102

71
Safety at work

Base is sold separately

A
D
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

Input1
1.1
AS-Interface + D
Field application

+
ϑ
I/O Modules

1.2 Pt100
AS-Interface - Sensor
Order code 1.3
2-wire
-
VBA-4E-G4-Pt100
Input 2
G4 module IP65 . 2.1
. +
. µP MUX
4 inputs for Pt100 2.2
Analogue modules

Sensor
2.3
-

Input 3
Features 3.1 ϑ
+ Pt100
• Protection degree IP65 A 3.2 3-wire
Sensor
• Flat or round cable connection (via 3.3
-
standardised EMS base, not included
Other modules

in the delivery package) Input 4


4.1
+
• Cable piercing method for flat cable 4.2
Sensor
• Function display for bus and inputs 4.3
-
Inductive sensors

Indicating/operating means
Photoelectric
sensors

analogue 1
analogue 2
analogue 3
PWR
FAULT

analogue 4

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
194 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface analogue module VBA-4E-G4-Pt100
Technical data Function

Masters and
Indicators/operating means

Gateways
The VBA-4E-G4-Pt100 analogue module
LED FAULT error display; LED red
has four analogue inputs for Pt100 RTDs.
red: communication error
red flashing: periphery fault The asynchronous transformation of meas-
LED PWR AS-Interface voltage; LED green ured values and the data transfer is accom-
LED ANALOG status of input signal; LED green plished in accordance with AS-Interface
profile 7.3. The resolution of the analogue

Extender, Repeaters
off: not connected (periphery fault)

Power Supplies,
green: signal within measurement range values is 16 bit or 0.1 °C. System distur-
green flashing: signal outside of measurement range (periph-
bances are eliminated using a programmable
ery fault)
filter (50 Hz/60 Hz).
Electrical specifications
The IP65 rated G4 module is especially suit-
Protection class III
able for use in hazardous environments.
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
Connection to the measured-value transmit-
Rated operational current Ie ≤ 80 mA
ters is established by means of cable glands
Input

Safety at work
and cage tension spring terminals thus mak-
Number/Type 4 inputs for Pt100, 2- or 3-wire connection ing the installation especially user-friendly.
Supply from AS-Interface For pre-addressing the module, it can be
Resolution 16 Bit / 0.1 °C plugged directly onto the adapter of the
Programming instructions hand-held programming device VBP-HH1.
Profile S-7.3.E Various bases are available for the module.
IO code 7 Use the U-G1F base to connect to the AS-

Control cabinet
ID code 3 Interface flat cable, and the U-G1P base to

I/O Modules
ID2 code E connect to the round cable. The bases can,
Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile at the same time, be used as IP67 rated dis-
7.3. tributor box. Moreover, they both have two
Parameter bits (programmable via AS-i) function connection possibilities for AS-Interface
P0 mains power frequency filter cables.
P0=1, 50 Hz filter active
Output modules often have to be mounted in

Field application
P0=0, 60 Hz filter active
series with input modules. The outputs of the

I/O Modules
P1/P2 Communication of the peripheral fault on measuring channels
1 to 4: output modules are supplied externally with
power. If the power is supplied via a flat
P1 P2 1 2 3 4
cable, the power cable has to be mounted in
0 0 ✓ – – –
the base of the input module. The U-G1FF
0 1 ✓ ✓ – –
base should be used in this case. The VBA-
1 0 ✓ ✓ ✓ –

Analogue modules
4E-G4-Pt100 then uses the AS-Interface
1 1 ✓ ✓ ✓ ✓
cable instead of the power cable.
P3 configuration Pt100
P3=1, 2-wire connection Accessories
P3=0, 3-wire connection
Ambient conditions VBP-HH1
Ambient temperature 0 ... 70 °C (273 ... 343 K) Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)

Other modules
Mechanical specifications
VAZ-G4-B
Protection degree IP65 according to EN 60529
Blind plug PG7
Connection cable piercing method or terminal compartment
flat cable yellow or standard round cable Matching system components
inputs: screwed connection M12 x 1,5 and cage-clamp termi-
nals U-G1F

Inductive sensors
Mass 350 g Base for connection to flat cable (EMS;
Mounting DIN rail AS-Interface only)
U-G1FA
Base with addressing jack for connection
to flat cable (EMS; AS-Interface only)
U-G1P
Photoelectric

Base for connection to round cable


sensors

(EMS;
AS-Interface only)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 195
VBA-2E-G4-I

AS-Interface analogue module VBA-2E-G4-I


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work

A
D
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

1.1 +
AS-Interface +
Field application

5.6 kΩ

Channel 2
1.2
I/O Modules

Signal 2+

not used
AS-Interface -
Order code 1.3 -
VBA-2E-G4-I
. 2.1
G4 module IP65 .
Signal 2-
. µP 2.2
2 analogue inputs (current) Screen
Analogue modules

2.3 Screen
2-wire 3-wire 4-wire
3.1 +
Features + U+ U+
3.2 -
• Protection degree IP65 Signal 1+ OUT OUT+

Channel 1
• Flat or round cable connection (via U-
standardised EEMS base, not 3.3
Other modules

- U-
included in the delivery package) AUX+ U+
4.1 Signal 1- OUT-
AUX- U-
• Cable piercing method for flat cable 4.2
Functional ground (FG)
Plug-in jumpers
• Function display for bus, external 4.3

auxiliary voltage and inputs


Inductive sensors

• Supply of inputs external or from the


module, as required

Indicating/operating means
Photoelectric
sensors

analogue 1
analogue 2
AUX
PWR
FAULT

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Plug-in jumper:
Power supply of inputs from
the external auxiliary power

Power supply of inputs from


Accessories

the module (AS-Interface)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
196 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface analogue module VBA-2E-G4-I
Technical data Function

Masters and
Indicators/operating means

Gateways
The VBA-2E-G4-I analogue module has two
LED FAULT error display; LED red
analogue current inputs 4 mA ... 20 mA. The
red: communication error
red flashing: periphery fault asynchronous transformation of measured
LED PWR AS-Interface voltage; LED green values and the data transfer is accomplished
LED ANALOG status input signal; LED green in accordance with AS-Interface profile 7.3.
The measured-value transmitter can be sup-

Extender, Repeaters
off: 1 < 1 mA (periphery fault)

Power Supplies,
green: 1 mA ≤ I ≤ 1 23 mA plied from the AS-Interface or from the exter-
green flashing: I > 23 mA (periphery fault)
nal auxiliary power via the black flat cable,
LED AUX ext. auxiliary voltage UAUX; LED green
depending on the wiring of the plug-in jump-
Electrical specifications ers. The resolution of the analogue values is
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV 16 bit. System disturbances are eliminated,
Protection class III using a programmable filter (50 Hz/60 Hz).
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface The IP65 rated G4 module is especially suit-
Rated operational current Ie ≤ 80 mA

Safety at work
able for rough conditions. Connection to the
Input measured-value transmitters is established
Number/Type 2 analogue inputs (currrent), 4 ... 20 mA by means of cable glands and cage tension
Supply from AS-Interface or from external auxiliary voltage as spring terminals thus making the installation
required UAUX especially user-friendly. For pre-addressing
Input resistance 50 Ω the module it can be plugged directly onto
Resolution 16 Bit / 1 µA the adapter of the hand-held programming

Control cabinet
Programming instructions device VBP-HH1.

I/O Modules
Profile S-7.3.D Both flat and round cables can be used for
IO code 7 the connection of the AS-Interface transmis-
ID code 3 sion line and the external 24 V DC power
ID2 code D supply. Use the U-G1FF base for the AS-
Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile Interface flat cable. The AS-Interface stand-
7.3. ardised EEMS interface, uses the cable

Field application
Parameter bits (programmable via AS-i) function piercing method to connect both the yellow

I/O Modules
P0 mains power frequency filter and black flat cables.
P0=1, 50 Hz filter active
P0=0, 60 Hz filter active
Use the U-G1PP base for a round cable. The
P1 projecting of the 2nd channel
AS-Interface cable as well as the external
P1=1, channel 2 is projected power supply may be connected within the
P1=0, channel 2 is not projected U-G1PP base.

Analogue modules
P2 Message of peripheral error
P2=1, periphery fault is reported
P2=0, periphery fault is not reported Accessories
P3 not used
VBP-HH1
Ambient conditions
Hand-held programming device
Ambient temperature 0 ... 70 °C (273 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K) VAZ-G4-B
Mechanical specifications Blind plug PG7

Other modules
Protection degree IP65 according to EN 60529
Connection cable piercing method or terminal compartment
flat cable yellow/flat cable black or standard round cable
Matching system components
inputs/outputs: 2 x screwed connection M16 x 1.5 and cage
clamp terminals, 1 x screwed connection M12 x 1.5 (not used)
U-G1FF
Mass 350 g
Base for connection to flat cable (EEMS;
Mounting DIN rail AS-Interface and external auxiliary pow-

Inductive sensors
er)
U-G1FFA
Base with addressing jack for connection
to flat cable (EEMS; AS-Interface and ex-
ternal auxiliary power)
U-G1PP
Photoelectric

Base for connection to round cable


sensors

(EEMS;
AS-Interface and external auxiliary volt-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

age)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 197
VBA-2E-G4-U

AS-Interface analogue module VBA-2E-G4-U


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work

A
D
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

1.1 +
AS-Interface +
Field application

Channel 2
1.2
I/O Modules

AS-Interface - Signal 2+
Order code 1.3 -
VBA-2E-G4-U
. 2.1
G4 module IP65 .
Signal 2-
. µP 2.2
2 analogue inputs (voltage) Screen
Analogue modules

2.3 Screen
2-wire 3-wire 4-wire
3.1 +
Features + U+ U+
3.2 -
• Protection degree IP65 Signal 1+ OUT OUT+

Channel 1
• Flat or round cable connection (via U-
standardised EEMS base, not 3.3
Other modules

- U-
included in the delivery package) AUX+ U+
4.1 Signal 1- OUT-
AUX- U-
• Cable piercing method for flat cable 4.2
Functional ground (FG)
Plug-in jumpers
• Function display for bus and inputs 4.3

• Supply of inputs external or from the


Inductive sensors

module, as required

Indicating/operating means
Photoelectric
sensors

analogue 1
analogue 2
AUX
PWR
FAULT

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Plug-in jumper:
Power supply of inputs from
the external auxiliary power

Power supply of inputs from


Accessories

the module (AS-Interface)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
198 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface analogue module VBA-2E-G4-U
Technical data Function

Masters and
Indicators/operating means

Gateways
The VBA-2E-G4-U analogue module has two
LED FAULT error display; LED red
analogue voltage inputs 0 V ... 10 V. The
red: communication error
red flashing: periphery fault asynchronous transformation of measured
LED PWR AS-Interface voltage; LED green values and the data transfer is accomplished
LED ANALOG status input signal; LED green in accordance with AS-Interface profile 7.3.
The measured-value transmitter can be sup-

Extender, Repeaters
off: not connected (periphery fault)

Power Supplies,
green: 0 V ≤ U ≤ 11.5 V plied from the AS-Interface or from the exter-
green flashing: U > 11.5 V (periphery fault)
nal auxiliary power via the black flat cable,
LED AUX ext. auxiliary voltage UAUX; LED green
depending on the wiring of the plug-in jump-
Electrical specifications ers. The resolution of the analogue values is
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV 16 bit. System disturbances are eliminated
Protection class III using a filter, programmable via P0
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface (50 Hz/60 Hz).
Rated operational current Ie ≤ 80 mA

Safety at work
The IP65 rated G4 module is especially suit-
Input able for rough conditions. Connection to the
Number/Type 2 analogue inputs (voltage), 0 ... 10 V measured-value transmitters is established
Supply from AS-Interface or from external auxiliary voltage as by means of cable glands and cage tension
required UAUX spring terminals thus making the installation
Input resistance 100 kΩ especially user-friendly. For pre-addressing
Resolution 16 Bit / 1 mV the module, it can be plugged directly onto

Control cabinet
Programming instructions the adapter of the hand-held programming

I/O Modules
Profile S-7.3.D device VBP-HH1.
IO code 7 Both flat and round cables can be used for
ID code 3 the connection of the AS-Interface transmis-
ID2 code D sion line and the external 24 V DC power
Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile supply. Use the U-G1FF base for the AS-
7.3. Interface flat cable. The AS-Interface stand-

Field application
Parameter bits (programmable via AS-i) function ardised EEMS interface, uses the cable

I/O Modules
P0 mains power frequency filter piercing method to connect both the yellow
P0=1, 50 Hz filter active
P0=0, 60 Hz filter active
and black flat cables.
P1 projecting of the 2nd channel
Use the U-G1PP base for a round cable. The
P1=1, channel 2 is projected AS-Interface-cable as well as the external
P1=0, channel 2 is not projected power supply may be connected within the

Analogue modules
P2 Message of peripheral error U-G1PP base.
P2=1, periphery fault is reported
P2=0, periphery fault is not reported
P3 not used Accessories
Ambient conditions
VBP-HH1
Ambient temperature 0 ... 70 °C (273 ... 343 K)
Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications VAZ-G4-B

Other modules
Protection degree IP65 according to EN 60529 Blind plug PG7
Connection cable piercing method or terminal compartment
flat cable yellow/flat cable black or standard round cable
inputs/outputs: 2 x screwed connection M16 x 1.5 and cage Matching system components
clamp terminals, 1 x screwed connection M12 x 1.5 (not used)
Mass 350 g
U-G1FF
Mounting DIN rail
Base for connection to flat cable (EEMS;

Inductive sensors
AS-Interface and external auxiliary pow-
er)
U-G1FFA
Base with addressing jack for connection
to flat cable (EEMS; AS-Interface and ex-
ternal auxiliary power)
Photoelectric

U-G1PP
sensors

Base for connection to round cable


(EEMS;
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface and external auxiliary volt-


age)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 199
VBA-2A-G4-I

AS-Interface analogue module VBA-2A-G4-I


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work

A
D
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

1.1 +
AS-Interface +
Field application

Channel 2
1.2
I/O Modules

AS-Interface - Signal 2+
Order code 1.3 -
VBA-2A-G4-I
. 2.1
G4 module IP65 .
Signal 2-
. µP 2.2
2 analogue outputs (current) Screen
Analogue modules

2.3 Screen
2-wire 4-wire
3.1 +
Features U+
3.2
• Protection degree IP65 Signal 1+ + IN+

Channel 1
• Flat or round cable connection (via
standardised EEMS base, not 3.3
Other modules

- U-
included in the delivery package) AUX+ U+
4.1 Signal 1- - IN-
AUX- U-
• Cable piercing method for flat cable 4.2
Functional ground (FG)
Plug-in jumpers
• Function display for bus, external 4.3

auxiliary voltage and outputs


Inductive sensors

• Power supply of outputs external or


from the module, as required

Indicating/operating means
Photoelectric
sensors

analogue 1
analogue 2
AUX
PWR
FAULT

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Plug-in jumper:

Power supply of outputs from


the external auxiliary power

Power supply of outputs from


Accessories

the module (AS-Interface)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
200 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface analogue module VBA-2A-G4-I
Technical data Function

Masters and
Indicators/operating means

Gateways
The VBA-2A-G4-I analogue module has two
LED FAULT error display; LED red
analogue current outputs 0 mA ... 20 mA.
red: communication error
red flashing: periphery fault Measured value conversion and data trans-
LED PWR AS-Interface voltage; LED green mission are performed asynchronously in
LED ANALOG status output signal; LED green accordance with AS-Interface profile 7.3.
Depending on how the plug-in jumpers are

Extender, Repeaters
off: not connected (periphery fault)

Power Supplies,
green: 0 mA ≤ I ≤ 23 mA wired, the outputs can be powered from the
green flashing: I > 23 mA (periphery fault)
AS-Interface or the external auxiliary power
LED AUX ext. auxiliary voltage UAUX; LED green
through the black flat wire. The resolution of
Electrical specifications analog values is 13 bits.
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV The G4 module in IP65 is particularly suita-
Protection class III ble for hard field use. The connection to the
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface outputs is established by screwed connec-
Rated operational current Ie ≤ 80 mA

Safety at work
tions and cage-clamp terminals. This makes
Output the installation especially user friendly. The
Number/Type 2 analogue outputs (current), 0 ... 20 mA module can be plugged directly onto the
Supply from AS-Interface or from external auxiliary voltage as adapter of the VBP-HH1 of the hand held
required UAUX programming device for pre-addressing.
Resolution 13 Bit / 1 µA The connection to the AS-Interface transmis-
Programming instructions sion line and the external 24 V DC power

Control cabinet
Profile S-7.3.5 supply can be made with flat wire or round

I/O Modules
IO code 7 cable. If AS-Interface flat wire is used, the
ID code 3 lower part of the U-G1FF should be used.
ID2 code 5 The contact to the two lines is made with the
Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile EEMS interface standardised for AS-Inter-
7.3. face, i. e. using the insulation penetration
Parameter bits (programmable via AS-i) function technique.

Field application
P0 not used For a round cable, the U-G1PP base should

I/O Modules
P1 projecting of the 2nd channel be used. Here as well, it is possible to con-
P1=1, channel 2 is projected
P1=0, channel 2 is not projected
nect both the AS-Interface lead and the
P2 Message of peripheral error
external power supply in the base.
P2=1, periphery fault is reported
P2=0, periphery fault is not reported
Accessories

Analogue modules
P3 not used
Ambient conditions VBP-HH1
Ambient temperature 0 ... 70 °C (273 ... 343 K) Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
VAZ-G4-B
Protection degree IP65 according to EN 60529 Blind plug PG7
Connection cable piercing method or terminal compartment
flat cable yellow/flat cable black or standard round cable Matching system components

Other modules
inputs/outputs: 2 x screwed connection M16 x 1.5 and cage
clamp terminals, 1 x screwed connection M12 x 1.5 (not used) U-G1FF
Mass 350 g Base for connection to flat cable (EEMS;
Mounting DIN rail
AS-Interface and external auxiliary pow-
er)

Inductive sensors
U-G1FFA
Base with addressing jack for connection
to flat cable (EEMS; AS-Interface and ex-
ternal auxiliary power)
U-G1PP
Base for connection to round cable
(EEMS;
Photoelectric

AS-Interface and external auxiliary volt-


sensors

age)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 201
VBA-2A-G4-U

AS-Interface analogue module VBA-2A-G4-U


Dimensions
Masters and
Gateways

31

90
Extender, Repeaters
Power Supplies,

80
66

71
102
Safety at work

A
D
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

1.1 +
AS-Interface +
Field application

Channel 2
1.2
I/O Modules

AS-Interface - Signal 2+
Order code 1.3 -
VBA-2A-G4-U
. 2.1
G4 module IP65 .
Signal 2-
. µP 2.2
2 analogue outputs (voltage) Screen
Analogue modules

2.3 Screen
2-wire 4-wire
3.1 +
Features U+
3.2 +
• Protection degree IP65 Signal 1+ IN+

Channel 1
• Flat or round cable connection (via
standardised EEMS base, not 3.3
Other modules

- U-
included in the delivery package) AUX+ U+
4.1 Signal 1- - IN-
AUX- U-
• Cable piercing method for flat cable 4.2
Functional ground (FG)
Plug-in jumpers
• Function display for bus, external 4.3

auxiliary voltage and outputs


Inductive sensors

• Power supply of outputs external or


from the module, as required

Indicating/operating means
Photoelectric
sensors

analogue 1
analogue 2
AUX
PWR
FAULT

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Plug-in jumper:

Power supply of outputs from


the external auxiliary power

Power supply of outputs from


Accessories

the module (AS-Interface)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
202 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface analogue module VBA-2A-G4-U
Technical data Function

Masters and
Indicators/operating means

Gateways
The VBA-2A-G4-U analogue module has two
LED FAULT error display; LED red
voltage outputs 0 V ... 10 V. The asynchro-
red: communication error
red flashing: periphery fault nous transformation of measured values and
LED PWR AS-Interface voltage; LED green the data transfer is accomplished in accord-
LED ANALOG status output signal; LED green ance with AS-Interface profile 7.3. The
measured-value transmitter can be supplied

Extender, Repeaters
off: not connected (periphery fault)

Power Supplies,
green: 0 V ≤ U ≤ 11.5 V from the AS-Interface or from the external
green flashing: U > 11.5 V (periphery fault)
auxiliary power via the black flat cable,
LED AUX ext. auxiliary voltage UAUX; LED green
depending on the wiring of the plug-in jump-
Electrical specifications ers. The resolution of the analogue values is
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV 13 bit.
Protection class III The IP65 rated G4 module is especially suit-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface able for rough conditions. Connection to the
Rated operational current Ie ≤ 80 mA

Safety at work
outputs is established by means of cable
Output glands and cage tension spring terminals
Number/Type 2 analogue outputs (voltage), 0 ... 10 V thus making the installation especially user-
Supply from AS-Interface or from external auxiliary voltage as friendly. For pre-addressing the module it can
required UAUX be plugged directly onto the adapter of the
Resolution 13 Bit / 1 mV hand-held programming device VBP-HH1.
Programming instructions Both flat and round cables can be used for

Control cabinet
Profile S-7.3.5 the connection of the AS-Interface transmis-

I/O Modules
IO code 7 sion line and the external 24 V DC power
ID code 3 supply. Use the U-G1FF base for the AS-
ID2 code 5 Interface flat cable. The AS-Interface stand-
Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile ardised EEMS interface, uses the cable
7.3. piercing method to connect both the yellow
Parameter bits (programmable via AS-i) function and black flat cables.

Field application
P0 not used Use the U-G1PP base for a round cable. The

I/O Modules
P1 projecting of the 2nd channel AS-Interface cable as well as the external
P1=1, channel 2 is projected
P1=0, channel 2 is not projected
power supply may be connected within the
P2 Message of peripheral error
U-G1PP base.
P2=1, periphery fault is reported
P2=0, periphery fault is not reported
Accessories

Analogue modules
P3 not used
Ambient conditions VBP-HH1
Ambient temperature 0 ... 70 °C (273 ... 343 K) Hand-held programming device
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
VAZ-G4-B
Protection degree IP65 according to EN 60529 Blind plug PG7
Connection cable piercing method or terminal compartment
flat cable yellow/flat cable black or standard round cable Matching system components

Other modules
inputs/outputs: 2 x screwed connection M16 x 1.5 and cage
clamp terminals, 1 x screwed connection M12 x 1.5 (not used) U-G1FF
Mass 350 g Base for connection to flat cable (EEMS;
Mounting DIN rail
AS-Interface and external auxiliary pow-
er)

Inductive sensors
U-G1FFA
Base with addressing jack for connection
to flat cable (EEMS; AS-Interface and ex-
ternal auxiliary power)
U-G1PP
Base for connection to round cable
(EEMS;
Photoelectric

AS-Interface and external auxiliary volt-


sensors

age)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 203
VBA-2E-KE2-I/U

AS-Interface analogue module VBA-2E-KE2-I/U


Dimensions
Masters and
Gateways

22.5 7 85
Extender, Repeaters
Power Supplies,

99
Safety at work

A
D
Control cabinet

Electrical connection
I/O Modules

Spec 2.1

2-wire 3-wire 4-wire


3
24V ext. U+ U+
AS-Interface - +
Field application

1 -
I/O Modules

AS-Interface + Sig + I/U I/U+


Order code 2
Sig - U- I/U-
VBA-2E-KE2-I/U 4
0V ext. U-
KE control cabinet module
µP
2 analogue inputs ADDR
7
Analogue modules

+ Connections
Input
5
Sig + 1 I1 Sig. +
. 2 I1 Sig. -
Features . 6
. Sig - 3 24 V ext.
4 0 V ext.
• Housing with removable terminals 8
- 5 I2 Sig. +
• Communication monitoring 6 I2 Sig. -
7 24 V ext.
Other modules

• Addressing jack UAUX+ U+


8 0 V ext.
9 U1 Sig. +
• Supply of inputs external or from the UAUX- U- 10 U1 Sig. -
module, as required 11 U2 Sig. +
Plug-in jumpers 12 U2 Sig. -
• Function indication for bus, internal 13 AS-Interface +
and external sensor power supply, 14 AS-Interface -
15 AUX +
Inductive sensors

inputs 16 AUX -

Indicating/operating means

I1 I1 24V 0V
Sig+ Sig- ext. ext. Beschriftungsfeld /
Vor dem Öffnen alle Anschlüsse
label field
Photoelectric

spannungsfrei schalten / I2 I2 24V 0V


de-energize all connections Sig+ Sig- ext. ext.
sensors

before opening
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

INPUT
1 Entriegeln / unlock 1 2 1 2 U
Auf BEIDEN Seiten drücken / OK I
press on BOTH sides FAULT INT
Rotary encoders

2 Öffnen / open
PWR AUX
Oberteil bis zum STOPP
herausziehen / ADDR
2
pull upper part until STOP
ON OFF
EXT
INT
3 Schalter einstellen / set switches
INT= Sensorversorgung aus AS-Interface /
sensor supply from AS-Interface
EXT= Sensorversorgung extern /
external sensor supply
2 ON= Kanal 2 an / Channel 2 on
Accessories

U1 U1 U2 U2
2 OFF= Kanal 2 aus / Channel 2 off Sig+ Sig- Sig+ Sig-
AS-i+ AS-i- AUX+ AUX-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
204 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface analogue module VBA-2E-KE2-I/U
Technical data Function

Masters and
Indicators/operating means

Gateways
The VBA-2E-KE2-I/U analog module is
LED FAULT error display; LED red
equipped with two analog inputs that can be
red: communication error
red flashing: periphery fault current inputs (4 mA ... 20 mA) or voltage
LED INT Internal input voltage active; LED green inputs (0 ... 10 V). The module can also be
LED PWR AS-Interface voltage; LED green connected as a combined current/voltage
module. In this case the module type must

Extender, Repeaters
LED AUX ext. auxiliary voltage UAUX; LED green

Power Supplies,
LED -/OK Status input signal; LED green be the same for each channel.
Off: Not connected (Only current module) Depending on the setting of the internal slid-
On: Signal within measuring range ing switch, the power supply for the measure-
Flashing: Signal outside measuring range
ment value transmitter is via the module
LED U/I Current or voltage module; Green LED
(from the AS-Interface) or through an exter-
Off: Voltage input
On: Current input nal power supply. The input power supply
Electrical specifications selection is displayed via the INT and AUX

Safety at work
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV
LEDs.
(protection class 3 according to VDE 0106/IEC 364-4-41) Measurement values are converted and data
Insulation voltage Ui ≥ 500 V is transferred asynchronously based on AS-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Interface Profile 7.3. The resolution of analog
Rated operational current Ie ≤ 80 mA values is 16 bits with a value range of
Input 4,000 ... 20,000 (current module) or
Number/Type 2 analogue inputs
0 ... 10,000 (voltage module). Power faults

Control cabinet
can be eliminated with a parameterizable fil-

I/O Modules
Current: 4 ... 20 mA
voltage: 0 ... 10 V ter (50 Hz/60 Hz) in the A/D converter.
Supply from AS-Interface or from external auxiliary voltage as The second channel can be turned off with a
required UAUX second slide switch to allow for faster data
Current loading capacity ≤ 40 mA per input transfer.
Input resistance For current module: 50 Ω The housing, only 22.5 mm in width, takes up
For voltage module: 100 kΩ
little place in the switch cabinet. The module

Field application
Switching point Changeover current/voltage module:
is installed by snapping on the 35-mm carrier

I/O Modules
current module with Iinput ≥ 1 mA
voltage module with Uinput ≥ 1 V rail in accordance with EN 50022.
Resolution 16 Bit / 1 µA (Current module) or It can be connected by plug-in terminals
16 bit / 1 mV (Voltage module) (COMBICON). 4X terminal blocks (black) are
Programming instructions used for the inputs. The connection of the
Profile S-7.3.D external auxiliary supply and AS-Interface is

Analogue modules
IO code 7 made through the 2-way-terminal blocks
ID code 3 (auxiliary supply gray, AS-Interface yellow).
ID2 code D This makes it possible to separate individual
Data bits (function via AS-Interface) The transfer of the data value is based on AS-Interface Profile sensors or to supply power during commis-
7.3. sioning or servicing.
Parameter bits (programmable via AS-i) function
P0 mains power frequency filter Note:
P0=1, 50 Hz filter active The device is equipped with communication

Other modules
P0=0, 60 Hz filter active
monitoring that turns off the outputs if no AS-
P1 projecting of the 2nd channel
P1=1, channel 2 is projected
Interface communication has taken place
P1=0, channel 2 is not projected with the device for more than 40 ms.
P2 Message of peripheral error An overload of the internal input supply is
P2=1, periphery fault is reported reported by the 'periphery error' to the AS-
P2=0, periphery fault is not reported Interface master. Communication over the

Inductive sensors
P3 not used AS-Interface remains in effect.
Standard conformity
Electromagnetic compatibility EN 50295, EN 61326
Accessories
Ambient conditions
Ambient temperature 0 ... 70 °C (273 ... 343 K) VBP-HH1
Storage temperature -25 ... 85 °C (248 ... 358 K) Hand-held programming device
Mechanical specifications
VAZ-PK-1,5M-V1-G
Photoelectric

Protection degree IP20 according to DIN 40050


removable terminals, terminal connection ≤ 2.5 mm2 Connection cable module/hand-held pro-
sensors

Connection
Mass 350 g gramming device
Mounting DIN rail
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 205
Photoelectric I/O Modules I/O Modules Power Supplies, Masters and
Accessories Rotary encoders sensors Inductive sensors Other modules Analogue modules Field application Control cabinet Safety at work Extender, Repeaters Gateways

206
AS-Interface - Ex Modules

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
AS-Interface - Ex Modules
5.4 Ex Modules

Masters and
Gateways
In the G5 design there are Ex modules for Zone 1 of a hazardous area. The
master and power supply should either be located outside Zone 1, or
mounted in an approved Ex housing.
Wiring in Zone 1 is carried out with increased safety (EEx e). The AS-Inter-

Extender, Repeaters
Power Supplies,
face connection can occur over the flat cable (the VAZ-PG11-FKD cable en-
try seal is also necessary) or round cable. Up to 4 NAMUR sensors can be
connected to the sensor input.
The module ist encapsulated (EEx m) and converts the intrinsically safe
NAMUR signal (EEx i) onto the AS-Interface The field circuits conform to ig-
nition protection class Ex ia IIC. The inputs are monitored for lead breakage

Safety at work
and short circuits (can be disabled for connection to mechanical contacts).
A version with 4 inputs and 2 outputs is available, as well as a version with
4 outputs; both have ATEX approval.

Instruction manual for the AS-Interface Ex system

Control cabinet
I/O Modules
1. Usage
• I/O modules are used as measuring and control devices to transfer binary signals within
hazardous areas or from hazardous areas to non-hazardous areas.
• The data sheets of the individual devices include the electrical data for the EC Type Exam-
ination Certificate, and are considered an integral part of the operating manual.

Field application
• The inputs and outputs conform to intrinsic safety ignition protection class "i", the bus to

I/O Modules
increased safety protection class "e" and the coupling modules to protection class "encap-
sulated housing m".
• Conformance to the standards and regulations applicable to the specified or intended
usage should be ensured.
• Devices which are operated in general electrical systems must not thereafter be operated

Analogue modules
in electrical systems that are connected with areas subject to the danger of explosions.
• I/O Modules are not suitable for the isolation of signals for power engineering. The manu-
facturer data sheets should also be adhered to.

2. Commissioning, installation
(Commissioning and installation may only be performed by professionals specifically trained to
do so.)
• The coupling modules conform to protection class IP54.

Other modules
• The coupling modules are suitable for installation in zone 1 of hazardous areas.
• Intrinsically safe circuits (light blue identification on the device) may be led into hazardous
areas; in this case, particular care must be taken to ensure secure isolation from all non-
intrinsically safe circuits. Installation must be performed in accordance with applicable man-
ufacturer guidelines.
• When using intrinsically safe circuits in Dust-Ex Zone "D", only field devices certified for this

Inductive sensors
use may be connected.
• When conneting intrinsically safe field devices to the intrinsically safe circuits of the cou-
pling module, the respective peak values of the field device and I/O module with regard to
explosion protection are to be used (Proof of Intrinsic Safety). EN 60079-14/IEC 60079-14
should be observed. In the case of Germany the "National foreword" in DIN EN 60079-
14/VDE 0165 Part 1 must be observed.
• The EU certificates of conformity or EU declarations of conformity should be observed. It is
particularly important to ensure that any "Special Conditions" in these documents are
Photoelectric

adhered to.
sensors

• Installation can be performed as direct walll mounting.


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

3. Maintenance
• The long-term stability of the device transmission functions eliminates the need for regular
adjustment or similar intervention. No other maintenance is required.
Rotary encoders

4. Fault elimination
• Devices operating in connection with hazardous areas must not be modified in any way.
Only qualified and authorised personnel are permitted to carry out device repairs.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 207
VAA-4E2A-G5-N/V2-Ex

AS-Interface sensor-/actuator module VAA-4E2A-G5-N/V2-Ex


Dimensions
Masters and
Gateways

184
173 46
Extender, Repeaters
Power Supplies,

∅ 6.5

129
150
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application

EEx e EEx ia IIC


I/O Modules

Order code Standard 2:1 Version 1 Version 2 Version 3 Version 4

+
AS-Interface

VAA-4E2A-G5-N/V2-Ex 11 + + +
+

10k

10k
12 - - -
G5 Ex module - 21 + + 1k
4 inputs/2 valve outputs - 22 - -
Analogue modules

31 + + * Diode necessary for 2:1 technique


32 - -

41 + +
Features 42 - -
• Use in hazardous area 51 +
52 -
• Category, ignition protection category
¬ II (1GD) 2G EEx em [ia] IIB/IIC T4 In-/ 61 +
Other modules

62 -
• Connection of 4 sensors based on Outputs
IEC 60947-5-6 (NAMUR, DIN 19234) EEx m
• Optional standard connection or 2:1
system (with polarized sensors)
Inductive sensors

• Connection of 2 switch valves


• Lead breakage and short-circuit
monitoring for inputs
• Function display for bus, status Indicating/operating means
display for inputs and outputs
Photoelectric
sensors

PWR
CHK
1 IN 1 OUT 2 IN 3 IN 2 OUT 4 IN
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

DIP-switch (in terminal compartment)


Rotary encoders

1 Short circuit monitoring (SC)


2 Lead breakage monitoring (LB)
3 Not used
4 2:1 Mode
OFF
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
208 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-4E2A-G5-N/V2-Ex
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E2A-G5-N/V2-Ex module is suita-
Slave type Standard slave ble for direct use in areas subject to the dan-
EC-Type Examination Certificate DMT 02 ATEX E 125 ger of explosion (Zone 1). The module itself
Group, category, type of protection ¬ II (1GD) 2G EEx em [ia] IIB/IIC T4 is encapsulated (EEx m), while the connec-
Intrinsically safe input and output circuits can be fed into areas
in the categories 1G and 1D. tion technology for the AS-Interface-lead is
designed for the increased safety category

Extender, Repeaters
Indicators/operating means

Power Supplies,
and the control circuits are designed to con-
LED PWR/CHK dual LED green/red
green: AS-Interface voltage form to EEx ia IIC.
red flashing: communication error or address 0 or SC/LK error The VAA-4E2A-G5-N/V2-Ex module makes it
LED IN 4 dual LED yellow/red possible to operate 4 sensors in accordance
yellow: switching state (input) with IEC 60947-5-6 (NAMUR) or mechanical
red flashing: SC/LK error contacts and 2 intrinsically safe valves. Four
LED OUT switching state (output); 2 LED yellow variations are possible for connecting the
Electrical specifications

Safety at work
sensors/mech. contacts (see electrical con-
Safety maximum voltage Um 40 V nection):
Short-circuit current Ik ≤ 35 A Variant 1: Connection of NAMUR sensors,
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface see connection assignment.
Rated operational current Ie ≤ 350 mA Variant 2: If the mechanical contacts are
Time delay before availability tv ≤1s wired according to the connection diagram,
Input monitoring for lead breakage and short-cir-

Control cabinet
Number/Type 4 inputs according to IEC 60947-5-6 (NAMUR, DIN 19234) cuit is possible.

I/O Modules
Switching point OFF ≤ 1.2 mA Variant 3: If the mechanical contacts are
ON ≥ 2.1 mA provided with only one 10 kW parallel resis-
Values in accordance with prototype test tor, the lead can be monitored for lead break-
certificate age. In this case, short-circuit monitoring
Voltage U0 ≤ 8.8 V DC must be turned off.
Current I0 ≤ 6 mA Variant 4: No type of monitoring at all is

Field application
Power P0 ≤ 13 mW available for this variant. In this case, lead

I/O Modules
Internal resistor Ri ≥ 1588 Ω breakage monitoring and short-circuit moni-
Internal capacitance Ci negligible toring must be turned off.
Internal inductance Li negligible The DIP switches are located in the terminal
Type of protection EEx ia IIB EEx ia IIC compartment for sensor/valve connections
External capacitance C0 ≤ 46 µF ≤ 5.5 µF (see the representation of the DIP switches).
External inductance L0 ≤1H ≤ 0.6 H

Analogue modules
L/R ratio L0/R0 ≤ 11 mH/Ω ≤ 2.9 mH/Ω Lead breakage / short-circuit:
Characteristic curve linear Error monitoring is activated when the cur-
Output rent in the control circuit I is less than 0.1 mA
Number/Type 2 outputs for control of intrinsically valves (lead breakage) or greater than 6 mA (short
Values in accordance with prototype test circuit).
certificate
In this case the LED of the input in question
Voltage U0 ≤ 28 V DC
and the LED PWR/CHK both flash red, and

Other modules
Current I0 ≤ 110 mA
the module logs out from the AS-Interface.
Power P0 ≤ 770 mW
Internal resistor Ri ≥ 258 Ω
Note:
Type of protection EEx ia IIB EEx ia IIC
If two channels are connected incorrectly, the
External capacitance C0 ≤ 650 nF ≤ 83 nF
output voltage may be reduced. To reset a
External inductance L0 ≤ 10 mH ≤ 1 mH
module, it has to be disconnected from the
L/R ratio L0/R0 ≤ 180 µH/Ω ≤ 46 µH/Ω

Inductive sensors
supply.
Characteristic curve linear
Nominal values (typically)
2:1 Mode:
Open loop voltage UA0 26 V
The 2:1 mode enables any two sensors to be
Short-circuit current IAK 50 mA
connected via a common 2-wire cable. Since
Internal resistor RI 270 Ω
in this mode the selection of the individual
Curve angle pointsurve angle 12.5 V DC, 50 mA
sensors is made via the polarity of the sen-
points((nominal values) UE/IE
sor supply, reverse polarity-protected sen-
Photoelectric

Programming instructions
sors must be used for this operating mode.
sensors

Profile S-7.F
Sensors 1 and 3 form the first pair; sensors 2
IO code 7
and 4 the second. The sensors of a pair are
ID code F
connected anti-parallel to the module via a 2-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Data bits (function via AS-Interface) input output


wire cable. The first pair occupy terminals 12
D0 IN1 OUT1
and 32 (Sensor 1 + to terminal 32, Sensor
D1 IN2 -
Rotary encoders

3 + to terminal 12). The second pair occupy


D2 IN3 OUT2
terminals 22 and 42 (Sensor 2 + to
D3 IN4 -
terminal 42, Sensor 4 + to terminal 22).
Parameter bits (programmable via AS-i) function
For mechanical contacts a serial diode is
P0/P1 (Output conditions on failure of the AS-Interface communica-
required for reverse polarity protection for
tion or LB/LK error)
0/0 outputs unchanged operation in the 2:1 mode.The connection is
0/1 outputs not controllable made in the same sense as for the sensors
1/0 outputs controllable (Contact 1 + to terminal 32, Contact 3 + to
Accessories

1/1 outputs not controllable


terminal 12, etc.).
P2 not used
The 2:1 mode is activated via DIP switch 4 in
P3 not used
the terminal compartment for the inputs and
outputs. To activate and deactivate the mode

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 209
AS-Interface sensor-/actuator module VAA-4E2A-G5-N/V2-Ex
the supply voltage (AS-Interface) must be Ambient conditions
briefly isolated from the device. Ambient temperature -20 ... 60 °C (253 ... 333 K)
Masters and
Gateways

Storage temperature -20 ... 85 °C (253 ... 358 K)


Mechanical specifications
Protection degree IP54 according to EN 60529
Connection screw terminals
Mass 1.5 kg
Extender, Repeaters

Mounting screw mounting


Power Supplies,

Notes
Valve coupler:
The block diagram at right illustrates the combined effect of the module and a valve switch.
The module, with respect to the valve, provides a power source with internal resistance. The
input circuit of the valve corresponds to the load resistance RA of this circuit. Minimum cur-
Safety at work

rents and voltages must be available on the valve in order for the valve to switch correctly.
The voltage URL drops across the cable resistance RL due to the current IRA, which is the
same throughout.

Ri RL
Control cabinet

URL
I/O Modules

UA/IAK

URA
G RA
Field application
I/O Modules

IRA

G: Generator
Ri: Internal resistor
RL: Lead resistance
Analogue modules

RA: Load resistor


UA0: Quiescent voltage
UA: Output voltage
URL: Voltage drop on
lead resistance
URA: Voltage drop on load
U0: max. voltage
I0: max. current
Other modules

IAK: Short-circuit current


IRA: Load current

The output characteristic diagram at right shows the generator characteristic and the resist-
ance line of the valve. The difference between the URA and the actual output voltage UA
Inductive sensors

meets the maximum voltage drop across the cable. From that, the maximum cable length and
resistance can be calculated.
However, the calculation does not take into account the requirements per DIN EN 50020
(Instrinsic Safety).Therefore, the user should test the system to ensure that maximum values
for external inductance and capacitance are not exceeded.

Output characteristic
E: Curve angle point (UE/IE)
Photoelectric
sensors

U Output characteristic
UO
UAO
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

UA E
URL
URA
Rotary encoders

IRA IAK IO I

unpermissible area for valves


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
210 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
211
Notes

Accessories Rotary encoders Photoelectric Inductive sensors Other modules Analogue modules I/O Modules I/O Modules Safety at work Power Supplies, Masters and
sensors Field application Control cabinet Extender, Repeaters Gateways
VAA-4A-G5-V2-Ex

AS-Interface actuator module VAA-4A-G5-V2-Ex


Dimensions
Masters and
Gateways

184
173 46
Extender, Repeaters
Power Supplies,

∅ 6.5

129
150
Safety at work
Control cabinet

Electrical connection
I/O Modules
Field application
I/O Modules

Order code EEx e


AS-i +
VAA-4A-G5-V2-Ex AS-i +
G5 Ex module AS-i -
EEx ia IIC
4 valve outputs AS-i -
Analogue modules

11
12

21
22
Features
31
• Use in hazardous area 32

• Category, ignition protection category 41


42
¬ II (1GD) 2G EEx em [ia] IIB/IIC T4
Other modules

• Outputs EEx ia IIC Outputs


• Connection of 4 switch valves EEx m

• Function display for bus and outputs


Inductive sensors

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

PWR
1 OUT 2 OUT 3 OUT 4 OUT CHK
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
212 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface actuator module VAA-4A-G5-V2-Ex
Technical data Function

Masters and
General specifications

Gateways
The VAA-4A-G5-V2-Ex module can be
Slave type Standard slave installed in zone 1 hazardous areas. The
EC-Type Examination Certificate DMT 99 ATEX E 072 module itself is encapsulated (EEx m), while
Group, category, type of protection ¬ II (1GD) 2G EEx em [ia] IIB/IIC T4 the connection system of the AS-i cable is
Intrinsically safe input and output circuits can be fed into areas
in the categories 1G and 1D. designed for use with increased safety.
The VAA-4A-G5-V2-Ex can be connected to

Extender, Repeaters
Indicators/operating means

Power Supplies,
4 intrinsically safe switch valves, i. e. the con-
LED PWR/CHK dual-LED green/red
green: AS-Interface voltage, normal operation trol circuit is intrinsically safe.
red: communication error or address 0
LED OUT switching state (output); 4 LED yellow Note:
Electrical specifications If two channels are connected incorrectly,
Safety maximum voltage Um 40 V the output voltage might be reduced. To reset
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface a module, it has to be disconnected from the

Safety at work
Rated operational current Ie ≤ 250 mA supply.
Time delay before availability tv ≤1s
Output
Number/Type 4 outputs EEx ia IIC for controlling intrinsically safe valves
Values in accordance with prototype test
certificate
Voltage U0 ≤ 28 V DC

Control cabinet
≤ 110 mA

I/O Modules
Current I0
Power P0 ≤ 770 mW
Internal resistor Ri ≥ 258 Ω
Type of protection EEx ia IIB EEx ia IIC
External capacitance C0 ≤ 650 nF ≤ 83 nF
External inductance L0 ≤ 10 mH ≤ 1 mH
Nominal values (typically)

Field application
I/O Modules
Open loop voltage UA0 26 V
Short-circuit current IAK 50 mA
Internal resistor RI 270 Ω
Curve angle pointsurve angle 12.5 V DC, 50 mA
points((nominal values) UE/IE
Programming instructions

Analogue modules
Profile S-8.F
IO code 8
ID code F
Data bits (function via AS-Interface) input output
D0 IN4 O4
D1 - OUT2
D2 - OUT3
D3 - OUT4

Other modules
Parameter bits (programmable via AS-i) function
P0/P1 (Output conditions on failure of the AS-Interface communica-
tion) 0/0 Outputs old value
0/1 outputs not controlled
1/0 outputs controlled
1/1 outputs not controlled
P2 not used

Inductive sensors
P3 not used
Ambient conditions
Ambient temperature -20 ... 65 °C (253 ... 338 K)
Storage temperature -20 ... 85 °C (253 ... 358 K)
Mechanical specifications
Protection degree IP54 according to EN 60529
Connection screw terminals
Photoelectric

Mass 1.5 kg
sensors

Mounting screw mounting


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 213
AS-Interface actuator module VAA-4A-G5-V2-Ex
Notes
Masters and
Gateways

Valve coupler:
The block diagram at right illustrates the combined effect of the module and a valve switch.
The module, with respect to the valve, provides a power source with internal resistance. The
input circuit of the valve corresponds to the load resistance RA of this circuit. Minimum cur-
rents and voltages must be available on the valve in order for the valve to switch correctly.
The voltage URL drops across the cable resistance RL due to the current IRA, which is the
Extender, Repeaters
Power Supplies,

same throughout.

Ri RL

URL
Safety at work

UA/IAK

URA
G RA

IRA
Control cabinet
I/O Modules

G: Generator
Ri: Internal resistor
RL: Lead resistance
RA: Load resistor
UA0: Quiescent voltage
Field application

UA: Output voltage


I/O Modules

URL: Voltage drop on


lead resistance
URA: Voltage drop on load
U0: max. voltage
I0: max. current
IAK: Short-circuit current
Analogue modules

IRA: Load current

The output characteristic diagram at right shows the generator characteristic and the resist-
ance line of the valve. The difference between the URA and the actual output voltage UA
meets the maximum voltage drop across the cable. From that, the maximum cable length and
resistance can be calculated.
However, the calculation does not take into account the requirements per DIN EN 50020
Other modules

(Instrinsic Safety).Therefore, the user should test the system to ensure that maximum values
for external inductance and capacitance are not exceeded.

Output characteristic
E: Curve angle point (UE/IE)
U
Inductive sensors

Output characteristic
UO
UAO
UA E
URL
URA
Photoelectric
sensors

IRA IAK IO I
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

unpermissible area for valves


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
214 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
215
Notes

Accessories Rotary encoders Photoelectric Inductive sensors Other modules Analogue modules I/O Modules I/O Modules Safety at work Power Supplies, Masters and
sensors Field application Control cabinet Extender, Repeaters Gateways
AS-Interface - AirBox
5.5 AirBox (Pneumatic Module)
Masters and
Gateways

Actuators are used in many parts of a system. On average, more than 40%
of them are pneumatic cylinders, controlled by compressed air. Long pres-
sure hoses, however, results in too-long response times, too-thick hoses,
unnecessary pressure losses and high costs when pressure lines must be
Extender, Repeaters

moved. So-called valve-island solutions are only appropriate when very


Power Supplies,

many valves must be driven in very little space. However, this is not always
the case, and here is where decentralized control with pneumatic modules
over AS-Interface shows clear advantages: fast response times, small air
volumes, simple installation, flexible extensibility, and low cost. Test opera-
tion can be performed using manual operation without a PLC connection,
and very little space is required. Up to 2 valves can be connected to a pneu-
Safety at work

matic module with 2 or 4 feedback inputs (max. 100 mA sensor power con-
sumption).
Devices with sinter filters (IP65) and with stainless steel air outlets (IP67) for
the food industry, both monostable or bistable, are available.
Control cabinet

These modules can only be driven over the yellow AS-Interface or with an
I/O Modules

optional 24 V auxiliary power supply over the black flat cable.


These modules cover the use of two independent 3/2-way valves each
(three pneumatic inputs/outputs and two connection paths).

Model number VAA-2EA- VAA-2EA- VAA-4E2A- VAA-4E2A-


Field application
I/O Modules

G1-ZE/P-S G1-ZE/P-V2A G1-ZE/P-S G1-ZE/PEXT-S


Sensor inputs 2 2 4 4
Logical outputs 2 2 2 2
AS-Interface power supply (yellow cable) ✓ ✓ ✓ ✓
Analogue modules

Auxiliary power supply (black cable) – – – ✓


Valve function 3/2 NC 2 2 2 2
Valve function 3/2 NO – – – –
Valve function 4/2 1 1 1 1
Valve function 5/2 – – – –
Valve function 5/3 ✓ ✓ ✓ ✓
Other modules

Middle position open 1 1 1 1


Middle position ventilated – – – –
Middle position closed – – – –
Air flow [Nl] 0/6 bar 550 550 550 550
Inductive sensors

Air flow [Nl] 5/6 bar 350 350 350 350


Pressure range [bar] 2 ... 8 2 ... 8 2 ... 8 2 ... 8
Additional drive air supply – – – –
Vacuum switchable – – – –
Exhaust outlet, filtered ✓ – ✓ ✓
Exhaust outlet, contained – ✓ – –
Photoelectric
sensors

Manual actuation ✓ ✓ ✓ ✓
tamper-proof ✩ – ✩ –
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Electrically bistable – – – –
Protection class IP65 IP67 IP65 IP65
Rotary encoders

✓ Standard
– not available
✩ on request

On request, the 4E2A pneumatic module is also available with flexible con-
duit connector and in stainless steel. Model numbers:AirBox 32 S-GE-MO
and AirBox 32 S-SW-MO (with ext. power supply).
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
216 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - AirBox
Pneumatic modules for 3/2-, 4/2, 5/2-, and 5/3-way valves are available as
special versions (data sheets on request). The modules include two inte-

Masters and
Gateways
grated pneumatic change-over contact outputs and are available in monos-
table and bistable versions.

Model number AirBox K AirBox K AirBox K AirBox K

Extender, Repeaters
F-GE-MO F-SW-MO F-GE-BI F-SW-BI

Power Supplies,
Sensor inputs 4 4 4 4
Logical outputs 2 2 2 2
AS-Interface power supply (yellow cable) ✓ ✓ ✓ ✓
Auxiliary power supply (black cable) – ✓ – ✓
Valve function 3/2 NC 2 2 2 2

Safety at work
Valve function 3/2 NO 2 2 2 2
Valve function 4/2 2 2 2 2
Valve function 5/2 2 2 2 2
Valve function 5/3 ✓ ✓ ✓ ✓
Middle position open 1 1 1 1

Control cabinet
I/O Modules
Middle position ventilated 1 1 1 1
Middle position closed – – – –
Air flow [Nl] 0/6 bar 700 700 700 700
Air flow [Nl] 5/6 bar 500 500 500 500

Field application
Pressure range [bar] 3 ... 8 3 ... 8 3 ... 8 3 ... 8

I/O Modules
Additional drive air supply ❍ ❍ ❍ ❍
Vacuum switchable ❍ ❍ ❍ ❍
Exhaust outlet, filtered ✓ ✓ ✓ ✓
Exhaust outlet, contained – – – –

Analogue modules
Manual actuation ✓ ✓ ✓ ✓
tamper-proof ✓ ✓ ✓ ✓
Electrically bistable – – ✓ ✓
Protection class IP65 IP65 IP65 IP65
Food industry ✩ ✩ ✩ ✩

Other modules
AS-Interface certification ✓ ✓ ✓ ✓
Ident number 93.025 93.027 93.031 93.026
3RK 1408-_ _ _ _ _ -0CA00 0MT00 1MT00 0CT00 1CT00
✓ Standard
– not available

Inductive sensors
❍ optional
✩ on request

KM K-FK-SW Base for AirBox K module with external power supply over ad-
ditional black flat cable, wall-mounted
KM K-HS Tophat rail adaptor for AirBox K base
Photoelectric

Selected technical data for AirBox K:


sensors

Total current consumption < 270 mA,


inputs: low < 1,5 mA / high > 6,5 mA or > 6 V,
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

current loading 100 mA (200 mA with ext. power supply)


short-circuit protected, max. switching frequency 5 Hz,
pressure range 3 bar ... 8 bar, filtered compressed air (oiled or non-oiled),
Rotary encoders

air flow 550 standard liter/min,


auxiliary air supply pressure > 3 bar,
protection class IP65,
dimensions 152 mm x 60 mm x 45 mm (HxWxD),
ambient temperature 0 °C ... 55 °C.
Accessories

All devices have UL, CSA, and AS-Interface approval.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 217
VAA-4E2A-G1-ZE/P-S

AS-Interface pneumatic module VAA-4E2A-G1-ZE/P-S


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,

90
102
52

80
Safety at work

37 48
45 60
Control cabinet

Electrical connection
I/O Modules

U
®
M12 x 1 quick disconnect
4 inputs IN1 ... IN4
Field application

Sensor + 1
IN+
I/O Modules

AS-Interface +
2
Order code IN2/IN4
AS-Interface -
4
VAA-4E2A-G1-ZE/P-S IN1/IN3
3
Pneumatic module Sensor - IN-
4 inputs/2 pneumatic outputs for 3-wire
Analogue modules

sensors
AS-i OUT 3/OUT4

Features
2 pneumatic outputs OUT3 and OUT4
• AS-Interface certificate
OUT
• Protection degree IP65
Other modules

• Flat or round cable connection (via


standardised EMS base, not included Air supply
in the delivery package) Outgoing air
• Cable piercing method for flat cable
• Inputs for 2- and 3-wire sensors
Inductive sensors

• Function display for bus, inputs and


outputs
• Direct connection of pneumatic
cylinders Indicating/operating means

Outgoing air
Photoelectric
sensors

IN1 IN3
IN1 4 4
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IN2
IN3
IN4 IN- IN+ IN- IN+
3 1 3 1
Rotary encoders

AS-i
OUT3 OUT4
2 2
IN2 IN4

Manual operation Manual operation


Accessories

for OUT3 for OUT4


Air supply

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
218 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface pneumatic module VAA-4E2A-G1-ZE/P-S
Technical data Function

Masters and
General specifications

Gateways
The VAA-4E2A-G1-ZE/P-S module features
Slave type Standard slave
4 inputs for the connection of 2- or 3-wire
Indicators/operating means sensors and 2 pneumatic outputs with a high
LED AS-i AS-Interface voltage; LED green air flow rate for direct control of pneumatic
LED IN switching state (input); 4 LED yellow drives in the field. 2 separate 3/2-way valves
LED OUT switching state (output); 2 LED yellow are integrated in the module. Both the valve

Extender, Repeaters
Power Supplies,
Electrical specifications and the sensors connected to the module
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface are supplied via the bus cable.
Rated operational current Ie ≤ 45 mA (without sensors) The sensors are connected to the module via
≤ 200 mA (complete) M12 x 1-circular connectors; the outputs are
Input connected to the pneumatic drive via stand-
Number/Type 2x 2 inputs for 2- or 3-wire sensors (PNP), DC ard hose plug-in connectors (LEGRIS LF
Supply from AS-Interface 3000, 8 mm).
≤ 100 mA, short-circuit proof

Safety at work
Current loading capacity Various bases are available for the mod-
Switching point OFF: ≤ 1.5 mA ule.The U-G1F (or U-G1FA) base provides
ON: ≥ 5 mA, ≥ 10 V the connection to the AS-Interface flat cable;
Output the U-G1P base provides the connection to a
Number/Type 2 pneumatic outputs with separated 3/2-way valves round cable.
Pneumatic output It happens very frequently that output mod-
Venting guide Sinter filter ules must be installed in series with the

Control cabinet
2 ... 8 bar, filtered (5 µm), oiled or unoiled compressed air pneumatic module. If the outputs of the out-

I/O Modules
Compressed air
Air throughput 550 Nl/min at 6/0 bar put modules are supplied with external
350 Nl/min at 6/5 bar power transferred via a flat cable, a suitable
Valve cross-section 5 mm EEMS base (U-G1FF or U-G1FFA) must be
Programming instructions used for the pneumatic module. In this case,
Profile S-7.F VAA-4E2A-G1-ZE/P-S accesses the AS-
IO code 7 Interface cable instead of the power supply

Field application
cable.

I/O Modules
ID code F
ID1 code F
ID2 code F Note:
Data bits (function via AS-Interface) input output The slave address must be programmed
D0 IN1 - before commissioning (default setting 0).
D1 IN2 - Medium: Filtered (5 µm), oiled or unoiled

Analogue modules
D2 IN3 OUT3 compressed air (2 ... 8 bars).
D3 IN4 OUT4
Parameter bits (programmable via AS-i) Warning:
P0 not used Dangerous electric voltage can lead to elec-
P1 not used tric shock and burns. The system must be
P2 not used disconnected from the power supply before
P3 not used the beginning of the works.
Ambient conditions

Other modules
Ambient temperature 0 ... 55 °C (273 ... 328 K) Accessories
Storage temperature -20 ... 85 °C (253 ... 358 K)
Mechanical specifications VBP-HH1
Protection degree IP65 according to EN 60529 Hand-held programming device
Connection cable piercing method or terminal compartment
flat cable or standard round cable Matching system components

Inductive sensors
inputs: M12 x 1 round connector
outputs: plug-in hose connector (8 mm) U-G1F
Mass approx. 200 g Base for connection to flat cable (EMS;
Mounting DIN rail or screw mounting
AS-Interface only)
U-G1P
Base for connection to round cable
(EMS;
Photoelectric
sensors

AS-Interface only)
U-G1FA
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Base with addressing jack for connection


to flat cable (EMS; AS-Interface only)
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 219
AS-Interface pneumatic module VAA-4E2A-G1-ZE/P-S
Notes
Masters and
Gateways

Examples for functions of the AS-Interface Airbox

as 3/2-way valve

ZU-Nr. Xxxxx ZU-Nr. Xxxxx ZU-Nr. Xxxxx


Extender, Repeaters

IN1 IN1 IN1


Power Supplies,

IN2 IN2 IN2

Power Power Power

OUT3 OUT4 OUT3 OUT4 OUT3 OUT4


Safety at work

as 4/2-way valve

ZU-Nr. Xxxxx ZU-Nr. Xxxxx


ZU-Nr. Xxxxx

IN1 IN1 IN1

IN2 IN2
Control cabinet

IN2
I/O Modules

Power Power Power

OUT3 OUT4 OUT3 OUT4 OUT3 OUT4


Field application
I/O Modules

as 5/2-way valvel

ZU-Nr. Xxxxx ZU-Nr. Xxxxx ZU-Nr. Xxxxx ZU-Nr. Xxxxx


IN1 IN1 IN1 IN1

IN2 IN2 IN2 IN2


Analogue modules

Power Power Power Power

OUT3 OUT4 OUT3 OUT4 OUT3 OUT4 OUT3 OUT4


Other modules

as 5/2-way valve
Unpressurized Pressurized Switched

ZU-Nr. Xxxxx ZU-Nr. Xxxxx ZU-Nr. Xxxxx

IN1 IN1 IN1

IN2 IN2 IN2


Inductive sensors

Power Power Power

OUT3 OUT4 OUT3 OUT4 OUT3 OUT4


Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
220 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface
5.6 Display and control modules

Masters and
Gateways
illuminated pushbutton modules are used for decentralised control and dis-
play of status. There are two designs available.
The LT2 illuminated pushbutton module in the G1 design has two integrated
buttons, to which 2 inputs and 2 outputs can be connected. The outputs

Extender, Repeaters
Power Supplies,
must be set by the master, and the inputs can be assigned to functions
stored in the master. Due to its high IP67 protection class, this illuminated
pushbutton module can also be used in the field.
Up to 6 illuminated pushbuttons can be installed in the LT3 modules in the
F86 construction type. The 94 x 180 mm housing can be used with stand-
ard installation modules of 22 m diameter. The assignment to the AS-Inter-

Safety at work
face connection integrated with ground proceeds over single wires on the
built-in buttons. In the basic version, there are 4 inputs and 4 outputs avail-
able. An extension board allows the module to be extended to 8 inputs and
8 outputs.

Control cabinet
5.7 Printed circuit board module

I/O Modules
To integrate AS-Interface into existing devices, we also carry circuit board
solutions (type code CB). Standard boards with up to 4 inputs and 4 outputs
are available, as well as special prefabricated solutions or build-in modules
in a plastic housing. New customer-specific solutions are also simply and

Field application
I/O Modules
quickly implemented. Pins, single wires, or terminals may be selected as
standard connection type.

Analogue modules
5.8 Engine starter
Frequency converters for the speed regulation of motors and drives are be-
ing installed decentrally in the field more and more often.
AS-Interface enables drives and motors to be decentrally controlled, too.
The robust design of the VAA-1E3A-M18-ZE/E2-V1 module in an M18

Other modules
housing is also suitable for harsh industrial applications and is easy to
screw into many devices and flexible for wiring. Since some motors also
have M25 screwed connections, the module includes an M25 adaptor for
mounting. The engine starter is externally connectable to the AS-Interface
flat cable using an M12 connector. The engine starter provides one input

Inductive sensors
and 3 outputs (for instance, for fast/slow/stop), which use an external power
supply. For address configuration, the engine starter can simply be plugged
into the VBP-HH1 handheld.
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 221
VAA-LT2-G1

AS-Interface pushbutton module VAA-LT2-G1


Dimensions
Masters and
Gateways

45 30
Extender, Repeaters
Power Supplies,

52

80
Safety at work

37
Control cabinet

Electrical connection
I/O Modules

U
®
Field application

AS-Interface +
I/O Modules

Order code AS-Interface -


Button 1
VAA-LT2-G1
Luminous push-button module
LED 1
Analogue modules

Features
• AS-Interface certificate Button 2

• Protection degree IP67


Other modules

• Flat or round cable connection (via LED 2


standardised EMS base, not included
in the delivery package)
• Cable piercing method for flat cable
• 2 integrated illuminated pushbuttons
Inductive sensors

• variable colours

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Button 1
standard: green
Rotary encoders

LED 1

Button 2
standard: red
LED 2
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
222 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface pushbutton module VAA-LT2-G1
Technical data Function

Masters and
General specifications

Gateways
The illuminated pushbutton module VAA-
Slave type Standard slave
LT2-G1 provides a link between the operat-
Indicators/operating means ing personnel and the AS-Interface master.
Button 2 integrated, The current status can be displayed by
protected against accidental activation,
keys can be individually labelled,
means of the LEDs integrated in the push-
buttons.

Extender, Repeaters
labeling field on the module

Power Supplies,
Electrical specifications The illuminated pushbutton has IP67 protec-
Protection class III
tion and is therefore suitable particularly for
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface
use in the field.
Rated operational current Ie ≤ 55 mA (LEDs on)
Various bases are available for the module.
Use the U-G1F base to connect to the AS-
Programming instructions
Interface flat cable, and use the U-G1P base
Profile S-3.F
to connect to the round cable.
IO code 3

Safety at work
The output modules often have to be
ID code F
mounted in series with the illuminated push-
Data bits (function via AS-Interface) input output
button. The outputs of the output modules
D0 Button 2 red -
are supplied externally with power. If the
D1 Button 1 green -
power is supplied via a flat cable, the power
D2 - LED 2 red
supply lead has to be mounted in the base of
D3 - LED 1 green
the input module. The U-G1FF base should

Control cabinet
Parameter bits (programmable via AS-i)
be used in this case. The VAA-LT2-G1 then

I/O Modules
P0 not used
uses the AS-Interface cable rather than the
P1 not used
power cable.
P2 not used
P3 not used
Ambient conditions Accessories
Ambient temperature -25 ... 60 °C (248 ... 333 K) VBP-HH1

Field application
Storage temperature -40 ... 85 °C (233 ... 358 K)

I/O Modules
Hand-held programming device
Mechanical specifications
Protection degree IP67 according to EN 60529
Connection cable piercing method or terminal compartment
Matching system components
flat cable or standard round cable
U-G1F
Base for connection to flat cable (EMS;

Analogue modules
AS-Interface only)
U-G1FA
Base with addressing jack for connection
to flat cable (EMS; AS-Interface only)
U-G1P
Base for connection to round cable

Other modules
(EMS;
AS-Interface only)

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 223
VAA-LT3-F86-V1

AS-Interface luminous push-button module VAA-LT3-F86-V1


Dimensions
Masters and
Gateways

94
79
80
45
2
Extender, Repeaters

ø22,3
Power Supplies,

(DN22 accord. to
EN 60947-5-1)

100
165
180
Safety at work
Control cabinet

Electrical connection
I/O Modules

1
8
Field application

AS-Interface + +
I/O Modules

4
Order code IN1
AS-Interface - 5
2 IN2
VAA-LT3-F86-V1 6
IN3
Luminous push-button module 7
IN4
4 inputs/4outputs
Analogue modules

Features 10
OUT1
• Empty housing for the installation of 11
OUT2
up to 6 built-in buttons, built-in lamps 12
OUT3 Load
or similar with diameter 22 mm 13
Other modules

OUT4
• Connection of the illuminated 9
pushbuttons via pluggable screw
terminals
• Protection degree IP65 possible
• Integrated communication monitoring
Inductive sensors

function
• Inputs and outputs short-circuit and
overload proof
Indicating/operating means
• No external power supply required
• M12 plug for simple connection to
AS-Interface
Photoelectric
sensors

AS-Interface + 1
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface - 2
IN1 4
IN2 5
IN3 6
Rotary encoders

IN4 7 Display
+ 8
- 9
OUT1 10 AS-Interface +
OUT2 11 1
OUT3 12
OUT4 13

4 2
Accessories

3
AS-Interface -

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
224 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface luminous push-button module VAA-LT3-F86-V1
Technical data Function

Masters and
General specifications

Gateways
The VAA-LT3-F86-V1 light sensor module
Slave type Standard slave
creates a connection between the operating
Electrical specifications personnel and the AS-Interface master. The
Protection class III housing is designed in combination with suit-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface able display and control elements in protec-
Rated operational current Ie ≤ 30 mA (without sensors) / max. 180 mA tion type IP65.

Extender, Repeaters
Power Supplies,
Input The internal AS-Interface I/O module is ide-
Number/Type 4 inputs for mechanical contacts ally suited to integrating customer-specific
Supply from AS-Interface electronics, for example light sensors or LED
Voltage 21 ... 31 V lights. The printed circuit board is supplied
Input current ≤ 8 mA (limited internally) entirely from the AS-Interface. The inputs
Switching point according to EN 61131-2 Typ 1 and outputs are protected against short cir-
0 (unattenuated) ≤ 1.5 mA cuits and overload and the connection
≥ 4 mA

Safety at work
1 (attenuated) between the display and control elements
Output and the AS-Interface circuit board can be
Number/Type 4 electronic outputs, PNP plugged in with screw-on plug-in terminals.
Supply from AS-Interface The connection to the AS-Interface is imple-
Current ≤ 100 mA per output, ≤ 140 mA total mented by means of a V1 round plug
Voltage 21 ... 31 V (M12 x 1).
Programming instructions An overloading of the outputs is signalled to

Control cabinet
the AS-Interface master via the "Peripheral

I/O Modules
Profile S-7.0
IO code 7 fault" function. Communication via the AS-
ID code 0 Interface remains intact.
ID1 code F The luminous push-button module can be
ID2 code E expanded to a total of 8 inputs/8 outputs by
Data bits (function via AS-Interface) input output means of an additional printed circuit board
module VAA-4E4A-CB1-Z/E2.

Field application
D0 IN1 OUT1

I/O Modules
D1 IN2 OUT2
D2 IN3 OUT3 Note:
D3 IN4 OUT4 Communication monitoring is integrated.
Parameter bits (programmable via AS-i) function This switches the outputs to a currentless
P0 not used state if no communication is taking place
P1 not used over the AS-Interface cable.

Analogue modules
P2 not used
P3 not used Accessories
Ambient conditions
Ambient temperature -25 ... 40 °C (248 ... 313 K)
VAA-4E4A-CB1-Z/E2
Storage temperature -40 ... 85 °C (233 ... 358 K) Printed circuit board module encapsulat-
Mechanical specifications ed in housing for expansion to 8 inputs/8
Protection degree IP65 according to EN 60529 (with compatible display and con- outputs

Other modules
trol elements)
Connection M12 round connector
VAZ-T1-FK-V1
Splitter box AS-Interface to 1x M12 round
Notes connector

LED displays should be used preferably, in order to avoid an exceeding of the max. current. VAZ-T1-FK-1M-PUR-V1-W
Splitter box AS-Interface to M12 round

Inductive sensors
connector

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 225
VAA-4EA-CB-E/E2-S

AS-Interface printed circuit board VAA-4EA-CB-E/E2-S


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,

37.5
R2

7
3.5
Safety at work

3.2
66
Control cabinet

Electrical connection
I/O Modules
Field application

4
+
1
I/O Modules

AS-Interface + 17 +
Order code AS-Interface -
2
16
E1
VAA-4EA-CB-E/E2-S 13
E2
Printed circuit board module 10
E3
4 inputs/4 outputs 7
E4
Analogue modules

15
A1 for 3-wire
12 sensors
A2
Features 9
A3
Load
• Integrated communication monitoring 6
A4
function
5
0
• Inputs and outputs short-circuit and
Other modules

8
0
overload proof 11
0
14
0
• No external power supply required
3 (free)
• Connection via screw terminals 18
(free)
Inductive sensors

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

PROG

AS-i +
AS-i -
NC

E1
A1

E2
A2

E3
A3

E4
A4
+

+
0

0
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
226 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface printed circuit board VAA-4EA-CB-E/E2-S
Technical data Function

Masters and
General specifications

Gateways
The VAA-4EA-CB-E/E2-S AS-Interface cou-
Slave type Standard slave
pling module is the circuit board solution for
Electrical specifications an AS-Interface slave. The module is ideal
Protection class III for integration into customer-specific elec-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface tronics, e. g. keypads, actuators, etc. The cir-
Rated operational current Ie ≤ 20 mA (without sensors) / max. 200 mA cuit board is supplied by the AS-Interface.

Extender, Repeaters
Power Supplies,
Input The inputs and outputs are short-circuit and
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC overload-proof.
Supply from AS-Interface
Voltage 21 ... 31 V Note:
Input current ≤ 8 mA (limited internally) In the case of communication errors on the
Switching point bus, the outputs are de-energised via an
0 (unattenuated) ≤ 1.5 mA integrated watchdog.
≥ 5 mA

Safety at work
1 (attenuated) Pepperl+Fuchs can customise connectors
Output and circuit board sizes e. g. for 2EA, 2E1A,
Number/Type 4 electronic outputs, PNP ... models to meet your specific applications.
Supply from AS-Interface
Current ≤ 45 mA per output, ≤ 180 mA total
Voltage 21 ... 31 V
Programming instructions

Control cabinet
I/O Modules
Profile S-7.0
IO code 7
ID code 0
Data bits (function via AS-Interface) input output
D0 IN1 OUT1
D1 IN2 OUT2

Field application
D2 IN3 OUT3

I/O Modules
D3 IN4 OUT4
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used
P3 not used

Analogue modules
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -40 ... 70 °C (233 ... 343 K)
Mechanical specifications
Protection degree IP20 (completely fitted) according to EN 60529
Connection screw terminal strip

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 227
VBA-4E3A-CB-E/E2-P

AS-Interface printed circuit board VBA-4E3A-CB-E/E2-P


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,

37.5
R2

7
3.5
Safety at work

3.2
66

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application

4
+
1
I/O Modules

AS-Interface + 17 +
Order code AS-Interface -
2
16
E1
VBA-4E3A-CB-E/E2-P 13
E2
Printed circuit board module 4 inputs / 10
E3
3 outputs 7
E4
Analogue modules

15
A1 for 3-wire
12 sensors
A2
Features 9
A3
Load
• A/B slave with extended addressing 6
A4
possibility for up to 62 slaves
5
0
• Integrated communication monitoring
Other modules

8
0
function 11
0
14
0
• Inputs and outputs short-circuit and
3
overload proof (free)
18
(free)
• No external power supply required
Inductive sensors

• Connection via pins

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

PROG

AS-i +
AS-i -
NC

E1
A1

E2
A2

E3
A3

E4
A4
+

+
0

0
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
228 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface printed circuit board VBA-4E3A-CB-E/E2-P
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E3A-CB-E/E2-P AS-Interface
Slave type A/B slave
coupling module is the circuit board solution
Electrical specifications for an AS-Interface slave. The module is
Protection class III ideal for integration into customer-specific
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface electronics, e. g. keypads, actuators, etc.
Rated operational current Ie ≤ 20 mA (without sensors) The circuit board is supplied by the AS-Inter-

Extender, Repeaters
Power Supplies,
Input face. The inputs and outputs are short-circuit
Number/Type 4 inputs for mechanical contacts and overload-proof.
Supply from AS-Interface
Voltage 21 ... 31 V Note:
Input current ≤ 8 mA (limited internally) In the case of communication errors on the
Switching point bus, the outputs are de-energised via an
0 (unattenuated) ≤ 1 mA integrated watchdog.
≥ 5 mA

Safety at work
1 (attenuated) Pepperl+Fuchs can customise connectors
Output and circuit board sizes e. g. for 2EA, 2E1A,
Number/Type 3 electronic outputs, PNP ... models to meet your specific applications.
Supply from AS-Interface
Current ≤ 80 mA per output, ≤ 80 mA total
Voltage 21 ... 31 V
Programming instructions

Control cabinet
I/O Modules
Profile S-7.A.E
IO code 7
ID code A
ID2 code E
Data bits (function via AS-Interface) input output
D0 IN1 OUT1

Field application
D1 IN2 OUT2

I/O Modules
D2 IN3 OUT3
D3 IN4 -
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used

Analogue modules
P3 not used
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -40 ... 70 °C (233 ... 343 K)
Mechanical specifications
Length of housing
Housing width

Other modules
Height of housing
Diameter of housing
Protection degree IP20 (completely fitted) according to EN 60529
Connection plug connector (pins)

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 229
VAA-4E4A-CB1-Z/E2

AS-Interface printed circuit board module VAA-4E4A-CB1-Z/E2


Dimensions
Masters and
Gateways

27
51 13

1
Extender, Repeaters

2
Power Supplies,

4
5
6
7
8

76
9
10
11
12
13
Safety at work
Control cabinet

Electrical connection
I/O Modules

1
8
Field application

AS-Interface + +
I/O Modules

4
Order code IN1
AS-Interface - 5
VAA-4E4A-CB1-Z/E2 2 IN2
6
IN3
Printed circuit board module encapsu- 7
IN4
lated in housing for expansion to 8 in-
Analogue modules

puts/8 outputs

Features 10
OUT1
• Integrated communication monitoring 11
OUT2
function 12
OUT3 Load
• Inputs and outputs short-circuit and 13
Other modules

OUT4
overload proof
9
• No external power supply required
• Connection via removable screw
terminals
Inductive sensors

Indicating/operating means
Photoelectric
sensors

AS-Interface + 1
AS-Interface - 2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

IN1 4
IN2 5
IN3 6
IN4 7
Rotary encoders

+ 8
- 9
OUT1 10
OUT2 11
OUT3 12
OUT4 13
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
230 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface printed circuit board module VAA-4E4A-CB1-Z/E2
Technical data Function

Masters and
General specifications

Gateways
The internal AS-Interface I/O module is ide-
Slave type Standard slave
ally suited to integrating customer-specific
Electrical specifications electronics, for example light sensors or LED
Protection class III lights. The printed circuit board is supplied
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface entirely from the AS-Interface. The inputs
Rated operational current Ie ≤ 30 mA (without sensors) / max. 180 mA and outputs are protected against short cir-

Extender, Repeaters
Power Supplies,
Input cuits and overload and the connection
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC between the display and control elements
Supply from AS-Interface and the AS-Interface circuit board can be
Voltage 21 ... 31 V plugged in with screw-on plug-in terminals.
Input current ≤ 8 mA (limited internally) The connection to the AS-Interface is imple-
Switching point according to EN 61131-2 Typ 1 mented by means of plug-in screw terminals.
0 (unattenuated) ≤ 1.5 mA An overloading of the outputs is signalled to
≥ 4 mA

Safety at work
1 (attenuated) the AS-Interface master via the "Peripheral
Output fault" function. Communication via the AS-
Number/Type 4 electronic outputs, PNP Interface remains intact.
Supply from AS-Interface
Current ≤ 100 mA per output, ≤ 140 mA total Note:
Voltage 21 ... 31 V Communication monitoring is integrated.
Programming instructions This switches the outputs to a currentless

Control cabinet
state if no communication is taking place

I/O Modules
Profile S-7.0
IO code 7 over the AS-Interface cable.
ID code 0
ID1 code F
ID2 code E
Data bits (function via AS-Interface) input output

Field application
D0 IN1 OUT1

I/O Modules
D1 IN2 OUT2
D2 IN3 OUT3
D3 IN4 OUT4
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used

Analogue modules
P2 not used
P3 not used
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications
Connection screw terminals, removable

Other modules
Notes
The AS-Interface I/O module is ideally suited to integrating customer-specific electronics, for
example light sensors or LED lights. The printed circuit board is supplied entirely from the AS-
Interface. The inputs and outputs are protected against short circuits and overload and the
connection between the display and control elements and the AS-Interface circuit board can

Inductive sensors
be plugged in with screw-on plug-in terminals. The connection to the AS-Interface is imple-
mented by means removable screw terminals.

Note:
Communication monitoring is integrated. This switches the outputs to a currentless state if no
communication is taking place over the AS-Interface cable.
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 231
VBA-4E3A-CB-E/E2-S

AS-Interface printed circuit board VBA-4E3A-CB-E/E2-S


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,

37.5
R2

7
3.5
Safety at work

3.2
66

62
Control cabinet

Electrical connection
I/O Modules

Spec 2.1
Field application

4
+
1
I/O Modules

AS-Interface + 17 +
Order code AS-Interface -
2
16
E1
VBA-4E3A-CB-E/E2-S 13
E2
Printed circuit board module 4 inputs / 10
E3
3 outputs 7
E4
Analogue modules

15
A1 for 3-wire
12 sensors
A2
Features 9
A3
Load
• A/B slave with extended addressing 6
A4
possibility for up to 62 slaves
5
0
• Integrated communication monitoring
Other modules

8
0
function 11
0
14
0
• Inputs and outputs short-circuit and
3
overload proof (free)
18
(free)
• No external power supply required
Inductive sensors

• Connection via screw terminals

Indicating/operating means
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

PROG

AS-i +
AS-i -
NC

E1
A1

E2
A2

E3
A3

E4
A4
+

+
0

0
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
232 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface printed circuit board VBA-4E3A-CB-E/E2-S
Technical data Function

Masters and
General specifications

Gateways
The VBA-4E3A-CB-E/E2-S AS-Interface
Slave type A/B slave
coupling module is the circuit board solution
Electrical specifications for an AS-Interface slave. The module is
Protection class III ideal for integration into customer-specific
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface electronics, e. g. keypads, actuators, etc.
Rated operational current Ie ≤ 20 mA (without sensors) The circuit board is supplied by the AS-Inter-

Extender, Repeaters
Power Supplies,
Input face. The inputs and outputs are short-circuit
Number/Type 4 inputs for mechanical contacts and overload-proof.
Supply from AS-Interface
Voltage 21 ... 31 V Note:
Input current ≤ 8 mA (limited internally) In the case of communication errors on the
Switching point bus, the outputs are de-energised via an
0 (unattenuated) ≤ 1 mA integrated watchdog.
≥ 5 mA

Safety at work
1 (attenuated) Pepperl+Fuchs can customise connectors
Output and circuit board sizes e. g. for 2EA, 2E1A,
Number/Type 3 electronic outputs, PNP ... models to meet your specific applications.
Supply from AS-Interface
Current ≤ 80 mA per output, ≤ 80 mA total
Voltage 21 ... 31 V
Programming instructions

Control cabinet
I/O Modules
Profile S-7.A.E
IO code 7
ID code A
ID2 code E
Data bits (function via AS-Interface) input output
D0 IN1 OUT1

Field application
D1 IN2 OUT2

I/O Modules
D2 IN3 OUT3
D3 IN4 -
Parameter bits (programmable via AS-i) function
P0 not used
P1 not used
P2 not used

Analogue modules
P3 not used
Ambient conditions
Ambient temperature -25 ... 70 °C (248 ... 343 K)
Storage temperature -40 ... 70 °C (233 ... 343 K)
Mechanical specifications
Protection degree IP20 (completely fitted) according to EN 60529
Connection screw terminal strip

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 233
VAA-1E3A-M18-ZE/E2-V1

AS-Interface sensor-/actuator module VAA-1E3A-M18-ZE/E2-V1


Dimensions
Masters and
Gateways
Extender, Repeaters
Power Supplies,

50
60
Safety at work

M12x1

M18x1
Control cabinet

Electrical connection
I/O Modules
Field application

Cable
I/O Modules

green
IN1
Order code M12 quick
disconnect
VAA-1E3A-M18-ZE/E2-V1 1 AS-Interface + yellow
OUT1
AS-Interface module in M18 stainless orange
OUT2
steel head ferrule 3 AS-Interface -
Analogue modules

brown
OUT3
1 input/3 outputs

Features PWR
• Input for 2-wire sensor FAULT
Load

• Function display for bus


4 AUX + red
Other modules

for connection AUX +


• For screwing in almost all metric 2 AUX - black
of UAUX AUX -
threads and PGs
• Unlimited addressing!
• Power supply of the inputs and
outputs from the external auxiliary
Inductive sensors

voltage
• Including M25 adapter to M18 x 1 for
connection to MOVIMOT
Indicating/operating means
Photoelectric
sensors

1
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

2 4
Rotary encoders

3
FAULT

PWR
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
234 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor-/actuator module VAA-1E3A-M18-ZE/E2-V1
Technical data Function

Masters and
General specifications

Gateways
The cylindrical AS-Interface module permits
Slave type Standard slave
an easy connection of standard actuators to
Indicators/operating means the AS-Interface. The input/output combina-
LED FAULT communication error / address is 0; LED red tion of 1:3 makes it particularly suitable for
LED PWR AS-Interface voltage; LED green operation with motors (start/stop, for-
Electrical specifications ward/reverse, rotational speed 1/2, alarm

Extender, Repeaters
Power Supplies,
Auxiliary voltage (output) UAUX 24 V DC ± 15 % PELV indication); this means that all other actua-
(protection class 3 according to VDE 0106/IEC 364-4-41) tors can also be easily connected to the AS-
Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Interface. By means of mechanical adaptor
Rated operational current Ie ≤ 20 mA nuts, the AS-Interface slave attaches to PG
Input cable glands as well as metric cable glands.
Number/Type 1 Input for 2-wire sensor MOVIMOT® from SEW-Eurodrive requires an
Supply from external auxiliary voltage UAUX M25 adaptor with M18 x 1 quick disconnects
OFF ≤ 0.8 mA

Safety at work
Switching point which is included in the delivery package.
ON ≥ 5 mA The mechanically strong and short design is
Output an advantage of the stainless steel head fer-
Number/Type 3 electronic outputs, PNP rule in well-tried and tested Pepperl+Fuchs
Supply from external auxiliary voltage UAUX quality.
Current 20 mA per output The M12 plug establishes a connection to
Programming instructions AS-Interface and to the auxiliary supply. Two

Control cabinet
LEDs show the voltage supply and AS-Inter-

I/O Modules
Profile S-9.F
IO code 9 face communication errors. Using additional
ID code F auxiliary power does not overload the AS-
ID2 code 0 Interface power supply. Therefore, up to
Data bits (function via AS-Interface) input output 31 cylinder modules can be connected to the
D0 IN4 O4 AS-Interface line.
D1 - OUT2

Field application
I/O Modules
D2 - OUT3
Accessories
D3 IN1 -
Parameter bits (programmable via AS-i) function VAZ-2T5-G2
P0 not used Splitter box AS-Interface and auxiliary
P1 not used voltage to 5 x M12 round connector
P2 not used

Analogue modules
P3 not used VAZ-2T1-FK-1M-PUR-V1-W
Ambient conditions Splitter box AS-Interface and auxiliary
Ambient temperature 0 ... 70 °C (273 ... 343 K) voltage to 1 x M12 round connector
Storage temperature -40 ... 70 °C (233 ... 343 K)
Mechanical specifications
Protection degree IP67 according to EN 60529
The protection class appplies only for installation of the module
in a connection housing for parts of the module located outside

Other modules
of the connection housing (external M12 connection, inside
cable connection).
The housing duct must be sealed with a suitable adhesive.
Connection AS-Interface and auxiliary voltage: M12x1 round connector
auxiliary voltage, input and outputs: 20 cm connection cable
Mass 110 g

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 235
AS-Interface - Inductive Sensors
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
236 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Inductive Sensors
6 Inductive AS-Interface Sensors

Masters and
Gateways
In previous system concepts with conventional wiring, VariKont®
the detection of sensor defects was difficult and would Rectangular sensors are available as surface-mount-
often lead to prolonged machine downtimes. ing sensors or in VariKont®, VariKont M® and VariKont
In a modern system concept, integrated chips provide L® housings. The VariKont L® housing is of particular

Extender, Repeaters
sensors with "intelligence" and extend their functional- interest.

Power Supplies,
ity. The sensors have an independent self-monitoring
and cable monitoring function, and can output data
messages to a higher-level unit, e.g. to a PLC.
Pre-fault indication
In practice, inductive sensors are set so that the dis-

Safety at work
tance between the object and the sensor corresponds
to approximately 50% of the maximum operating
range. The pre-fault indication is activated if the object
is only active in an area between 80% and 100% of the
maximum operating range. It indicates that the sensor

Control cabinet
is out of range. The advantage of this is that the mes-

I/O Modules
sage is made available before the sensor fails. The sensor head is convertible and may be rotated in
15° steps. It is fastened using 2 screws, which are also
Oscillator monitoring used to mount the sensor. This sensor has been de-
During oscillator monitoring, the oscillator coil is mon- veloped specifically for conveying applications.
itored in order that a fault in the coil, such as an open
The VariKont® and VariKont M® housings correspond

Field application
circuit, can be detected and indicated.

I/O Modules
to the mounting slot requirements of EN 60947 for me-
The 4 data bits in the messages also contain informa- chanical roller rocker end switches. They also permit
tion about the status of the N.C/N.O. contacts of the the rotation of the sensor heads. The VariKont® hous-
sensor, which can be modified if required by transfer- ing permits the head to be rotated in 90° steps, the Va-
ring the appropriate parameter: riKont M® housing in 15° steps. A special base (U9A)

Analogue modules
is available for the VariKont® housing, which enables
Parameter direct connection to the AS-Interface flat cable using
N.C. contact N.O. contact the cable-piercing technique.

31 or 62 of these intelligent sensors can be connected


in a single AS-Interface network per master. Various

Other modules
types of sensors are available from Pepperl+Fuchs.
Types
Embeddable and built in flush cylindrical sensors are
available in diameters M12 to M30. Conventional sen-
sors in stainless steel head ferrules with 2 mm round

Inductive sensors
cable or V1 plug connection with multiple LED display
are available as standard.
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 237
Inductive proximity switches NCB4-12GM60-B3B-V1

Order code
Masters and
Gateways

NCB4-12GM60-B3B-V1

Features
M12x1
• Cylindrical type
Extender, Repeaters
Power Supplies,

• Comfort series
• 4 mm embeddable

4
• A/B slave with extended

60
addressing possibility for 17

65
75
up to 62 slaves
• Cylindrical
Safety at work

• NO/NC selectable
• ON/Off delay (disconnect- LED
able)
6

M12x1
Control cabinet
I/O Modules

Programming Instructions
Technical data
Adress 00 preset, alterable
Rated operating distance sn 4 mm
via Busmaster
Installation embeddable
Field application

or programming units
I/O Modules

NO/NC programmable NCB4-12GM60-B3B-V1 IO-Code 0


ID-Code A
Assured operating distance sa 0 ... 3.24 mm
Reduction factor rAl 0.23 Data bit
Reduction factor rCu 0.21 Bit Function
D0 Switching state
Reduction factor rV2A 0.7
Analogue modules

D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 not used
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 500 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated
Other modules

P1 Switching element function


Indication of the switching dual-LED, yellow NO* / NC
state P2 not used
Fault indication dual-LED, red P3 not used
EMC in accordance with EN 60947-5-2
*Standard setting
Standards EN 60947-5-2
Inductive sensors

Ambient temperature -25 ... 70 °C


Connection type V1-connector
Housing material high grade steel
Sensing face PBT
Protection degree IP67
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
238 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NCN4-12GM60-B3B-C2-V1

Order code

Masters and
Gateways
NCN4-12GM60-B3B-C2-V1

Features
M12x1
• Cylindrical type

Extender, Repeaters
5

Power Supplies,
• Comfort series
• 4 mm not embeddable

4
• A/B slave with extended

60
addressing possibility for

65
17

75
up to 62 slaves
• Cylindrical

Safety at work
• NO/NC selectable
• ON/Off delay (disconnect- LED
able) 6
M12x1

Control cabinet
I/O Modules
Programming Instructions
Technical data
Rated operating distance sn 4 mm Adress 00 preset, alterable
via Busmaster
Installation not embeddable

Field application
or programming units

I/O Modules
NO/NC programmable NCN4-12GM60-B3B- IO-Code 0
C2-V1 ID-Code A

Assured operating distance sa 0 ... 3.24 mm Data bit


Reduction factor rAl 0.37 Bit Function
Reduction factor rCu 0.36 D0 Switching state

Analogue modules
D1 not used
Reduction factor rV2A 0.74 D2 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D3 not used
bus system
Parameter bit
Operating current Ie 25 mA
Bit Function
Switching frequency f 0 ... 500 Hz P0 ON / Off delay
Hysteresis H 1 ... 15 typ. 5 % activated* / deactivated

Other modules
Time delay before availability tv ≤ 1000 ms P1 Switching element function
NO* / NC
Alternating magnetic field B 100 mT P2 not used
Indication of the switching dual-LED, yellow P3 not used
state
*Standard setting
Fault indication dual-LED, red

Inductive sensors
EMC in accordance with EN 60947-5-2
Standards EN 60947-5-2
Ambient temperature -25 ... 70 °C
Connection type V1-connector
Housing material high grade steel
Sensing face PBT
Photoelectric

Protection degree IP67


sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 239
Inductive proximity switches NCB5-18GM60-B3B-V1

Order code
Masters and
Gateways

NCB5-18GM60-B3B-V1

Features
M18x1
• Cylindrical type
Extender, Repeaters
Power Supplies,

• Comfort series
• 5 mm embeddable
4

44
• A/B slave with extended

60
addressing possibility for
24

70
up to 62 slaves
• Cylindrical
Safety at work

• NO/NC selectable
• Stability control warning 6

• Installation help M12x1


• ON/Off delay (disconnect-
able)
• Oscillator monitoring
Control cabinet
I/O Modules

Programming Instructions
Technical data
Adress 00 preset, alterable
Rated operating distance sn 5 mm
via Busmaster
Installation embeddable
Field application

or programming units
I/O Modules

NO/NC programmable NCB5-18GM60-B3B-V1 IO-Code 0


ID-Code A
Assured operating distance sa 0 ... 4.05 mm
Reduction factor rAl 0.2 Data bit
Reduction factor rCu 0.15 Bit Function
D0 Switching state
Reduction factor rV2A 0.62
Analogue modules

D1 Prefailure message (dynamic)


Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 Object too close
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 100 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated
Other modules

P1 Switching element function


Operating voltage display dual-LED, green NO* / NC
Indication of the switching dual-LED, yellow/red P2 not used
state P3 not used
Fault indication dual-LED, red
*Standard setting
Standards EN 60947-5-2
Indicators
Inductive sensors

Ambient temperature -25 ... 70 °C


Connection type V1-connector LED red LED yellow
UAI OUT
Housing material high grade steel
LED red LED green
Sensing face PBT FAULT POWER
Protection degree IP67
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
240 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NCN8-18GM60-B3B-V1

Order code

Masters and
Gateways
NCN8-18GM60-B3B-V1

Features
M18x1
• Cylindrical type

Extender, Repeaters
Power Supplies,
• Comfort series

10
• 8 mm not embeddable

44
• A/B slave with extended

60
addressing possibility for
24

70
up to 62 slaves
• Cylindrical

Safety at work
• NO/NC selectable
• Stability control warning
6
• Installation help M12x1
• ON/Off delay (disconnect-
able)
• Oscillator monitoring

Control cabinet
I/O Modules
Programming Instructions
Technical data
Adress 00 preset, alterable
Rated operating distance sn 8 mm
via Busmaster
Installation not embeddable

Field application
or programming units

I/O Modules
NO/NC programmable NCN8-18GM60-B3B-V1 IO-Code 0
ID-Code A
Assured operating distance sa 0 ... 6.48 mm
Reduction factor rAl 0.42 Data bit
Reduction factor rCu 0.4 Bit Function
D0 Switching state
Reduction factor rV2A 0.72

Analogue modules
D1 Prefailure message (dynamic)
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 Object too close
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 100 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated

Other modules
P1 Switching element function
Operating voltage display dual-LED, green NO* / NC
Indication of the switching dual-LED, yellow/red P2 not used
state P3 not used
Fault indication dual-LED, red
*Standard setting
Standards EN 60947-5-2
Indicators

Inductive sensors
Ambient temperature -25 ... 70 °C
Connection type V1-connector LED red LED yellow
UAI OUT
Housing material high grade steel
LED red LED green
Sensing face PBT FAULT POWER
Protection degree IP67
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 241
Inductive proximity switches NC*1*-30GM70-B3-V1

Order code
Masters and
Gateways

NCB10-30GM70-B3-V1
NCN15-30GM70-B3-V1
M30x1,5
M30x1,5
Features
Extender, Repeaters

18
Power Supplies,

• Cylindrical type
• NO/NC selectable
• Comfort series 5

70
75
• 10 mm embeddable

70

85
75
• 15 mm not embeddable

85
• Prefailure message and 36 36
Safety at work

indicator
• Stability control warning
LED

6
LED
6

M12x1
M12x1
Control cabinet
I/O Modules

Technical data Programming Instructions


Rated operating distance sn 10 mm 15 mm Address 00 preset , alterable
Installation embeddable not embeddable via Busmaster or
Field application

programming units
I/O Modules

NO/NC programmable NCB10-30GM70-B3-V1 NCN15-30GM70-B3-V1 IO-code 1


Assured operating distance sa 0 ... 8.1 mm 0 ... 12.1 mm ID-code 1
Reduction factor rAl 0.32 0.38
Data bit
Reduction factor rCu 0.32 0.36
Reduction factor rV2A 0.72 0.72 Bit function
Analogue modules

Reduction factor rMs 0.43 0.45


D0 switching state
Operating voltage UB 26.5 ... 31.9 V via AS-i 26.5 ... 31.9 V via AS-i
bus system bus system D1 pre-fault signal (dynamic)
Operating current Ie 25 mA 25 mA
D2 ready for operation
Current consumption -
Measuring plate not ≥ 3 mA - D3 not used
Other modules

detected
Parameter bit
Measuring plate detected ≤ 1 mA -
Switching frequency f 0 ... 70 Hz 0 ... 50 Hz Bit function
Hysteresis H 1 ... 10 typ. 5 % typ. 5 %
P0 not used
Time delay before availability tv ≤ 1000 ms ≤ 1000 ms
Inductive sensors

Indication of the switching Multihole-LED, yellow Multihole-LED, yellow P1 switching element function
state NO* / NC
Standards EN 60947-5-2 EN 60947-5-2
P2 not used
Ambient temperature -25 ... 70 °C -25 ... 70 °C
Connection type V1-connector V1-connector P3 not used
Core cross-section - * Standard setting
Photoelectric

Housing material high grade steel high grade steel


sensors

Sensing face PBT PBT


Protection degree IP67 IP67
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

Electrical connection:

B3
1 / BN
Accessories

+
I
AS-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
242 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NBB6-F-B3

Order code

Masters and
Gateways
NBB6-F-B3

Features

12
• Rectangular type

Extender, Repeaters
Power Supplies,
• Basic series
• 6 mm embeddable 3,2

• NO/NC selectable LED

• Protection degree IP67


• Oscillator monitoring
30

18

Safety at work
9,5
45

Control cabinet
I/O Modules
Technical data Programming Instructions
Rated operating distance sn 6 mm Address 00 preset , alterable
Installation embeddable via Busmaster or

Field application
programming units

I/O Modules
NO/NC programmable NBB6-F-B3 IO-code 1
Assured operating distance sa 0 ... 4.86 mm ID-code 1
Reduction factor rAl 0.28
Data bit
Reduction factor rCu 0.25
Reduction factor rV2A 0.75 Bit function

Analogue modules
Operating voltage UB 26.5 ... 31.9 V via AS-i
D0 switching state
bus system
Operating current Ie 20 mA D1 not used
Hysteresis H typ. 5 %
D2 oscillator monitoring
Time delay before availability tv ≤ 1000 ms
Operating voltage display LED, green D3 not used

Other modules
Indication of the switching LED, yellow
Parameter bit
state
Standards EN 60947-5-2 Bit function
Ambient temperature -25 ... 70 °C
P0 not used
Connection type 2 m, PVC cable

Inductive sensors
Core cross-section 0.34 mm2 P1 switching element function
NO* / NC
Housing material PBT
P2 not used
Protection degree IP67
Mass 90 g P3 not used

* Standard setting
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3
1 / BN
Accessories

+
I
AS-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 243
Inductive proximity switches NBB20-L2-B3B-V1

Order code
Masters and
Gateways

NBB20-L2-B3B-V1
67

M12x1
Features
• VariKont L ®
Extender, Repeaters
Power Supplies,

• Basic series
• 20 mm embeddable
• A/B slave with extended
addressing possibility for 40,5 LEDs
up to 62 slaves
• Sensor head bi-directional
Safety at work

and rotatable
40

30
• NO/NC selectable
• Oscillator monitoring
• ON/Off delay (disconnect- 1

Ø 5,4
able) 46,5
55,5
Control cabinet
I/O Modules

Programming Instructions
Technical data
Rated operating distance sn 20 mm Adress 00 preset, alterable
via Busmaster
Installation embeddable
Field application

or programming units
I/O Modules

NO/NC programmable NBB20-L2-B3B-V1 IO-Code 0


ID-Code A
Assured operating distance sa 0 ... 16.2 mm
Reduction factor rAl 0.3 Data bit
Reduction factor rCu 0.3 Bit Function
D0 Switching state
Reduction factor rV2A 0.8
Analogue modules

D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 100 Hz Bit Function
Hysteresis H typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated
Other modules

P1 Switching element function


Operating voltage display LED, green
NO* / NC
Indication of the switching LED, yellow P2 not used
state P3 not used
Fault indication LED, red
*Standard setting
Standards EN 60947-5-2
Inductive sensors

Ambient temperature -25 ... 70 °C Indicators


Connection type V1-connector LED yellow
OUT
Housing material PBT
LED green
Sensing face PBT POWER
Protection degree IP67
LED red
Mass 210 g FAULT
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
244 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NBN30-L2-B3B-V1

Order code

Masters and
Gateways
NBN30-L2-B3B-V1
67

M12x1
Features
• VariKont L ®

Extender, Repeaters
Power Supplies,
• Basic series
• 30 mm not embeddable
• A/B slave with extended
addressing possibility for 40,5 LEDs
up to 62 slaves
• Sensor head bi-directional

Safety at work
and rotatable
40

30
• NO/NC selectable
• Oscillator monitoring
• ON/Off delay (disconnect- 1

Ø 5,4
able) 46,5
55,5

Control cabinet
I/O Modules
Programming Instructions
Technical data
Rated operating distance sn 30 mm Adress 00 preset, alterable
via Busmaster
Installation not embeddable

Field application
or programming units

I/O Modules
NO/NC programmable NBN30-L2-B3B-V1 IO-Code 0
ID-Code A
Assured operating distance sa 0 ... 24.3 mm
Reduction factor rAl 0.45 Data bit
Reduction factor rCu 0.4 Bit Function
D0 Switching state
Reduction factor rV2A 0.8

Analogue modules
D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 100 Hz Bit Function
Hysteresis H typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated

Other modules
P1 Switching element function
Operating voltage display LED green
NO* / NC
Indication of the switching LED yellow P2 not used
state P3 not used
Fault indication LED red
*Standard setting
Standards EN 60947-5-2

Inductive sensors
Ambient temperature -25 ... 70 °C Indicators
Connection type V1-connector LED yellow
OUT
Housing material PBT
LED green
Sensing face PBT POWER
Protection degree IP67
LED red
Mass 210 g FAULT
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 245
Inductive proximity switches NBN40-L2-B3B-V1

Order code
Masters and
Gateways

NBN40-L2-B3B-V1
67

M12x1
Features
• VariKont L ®
Extender, Repeaters
Power Supplies,

• Basic series
• 40 mm not embeddable
• A/B slave with extended
addressing possibility for 40,5 LEDs
up to 62 slaves
• Sensor head bi-directional
Safety at work

and rotatable
40

30
• NO/NC selectable
• Oscillator monitoring
• ON/Off delay (disconnect- 1

Ø 5,4
able) 46,5
55,5
Control cabinet
I/O Modules

Programming Instructions
Technical data
Rated operating distance sn 40 mm Adress 00 preset, alterable
via Busmaster
Installation not embeddable
Field application

or programming units
I/O Modules

NO/NC programmable NBN40-L2-B3B-V1 IO-Code 0


ID-Code A
Assured operating distance sa 0 ... 32.4 mm
Reduction factor rAl 0.5 Data bit
Reduction factor rCu 0.45 Bit Function
D0 Switching state
Reduction factor rV2A 0.85
Analogue modules

D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 150 Hz Bit Function
Hysteresis H typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated
Other modules

P1 Switching element function


Operating voltage display LED, green
NO* / NC
Indication of the switching LED, yellow P2 not used
state P3 not used
Fault indication LED, red
*Standard setting
EMC in accordance with EN 60947-5-2
Inductive sensors

Standards EN 50295 Indicators


Ambient temperature -25 ... 70 °C LED yellow
OUT
Connection type V1-connector
LED green
Housing material PBT POWER
Sensing face PBT
LED red
Protection degree IP67 FAULT
Photoelectric

Mass 210 g
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
246 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NBB20+U1+B3B

Order code

Masters and
Gateways
NBB20+U1+B3B

Features
• VariKont ®

Extender, Repeaters
Power Supplies,
• Basic series
• 20 mm embeddable
• NO/NC programmable
• Position of the sensor
head adjustable
• Oscillator monitoring

Safety at work
• ON/Off delay (disconnect-
able)
• A/B slave with extended
addressing possibility for
up to 62 slaves

Control cabinet
I/O Modules
Programming Instructions
Technical data
Rated operating distance sn 20 mm Adress 00 preset, alterable
via Busmaster
Installation embeddable

Field application
or programming units

I/O Modules
NO/NC programmable NBB20+U1+B3B IO-Code 0
ID-Code A
Assured operating distance sa 0 ... 16.2 mm
Reduction factor rAl 0.4 Data bit
Reduction factor rCu 0.35 Bit Function
D0 Switching state
Reduction factor rV2A 0.85

Analogue modules
D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 150 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated

Other modules
P1 Switching element function
Operating voltage display LED, green
NO* / NC
Indication of the switching LED, yellow P2 not used
state P3 not used
Fault indication LED, red
*Standard setting
EMC in accordance with EN 60947-5-2

Inductive sensors
Standards EN 60947-5-2
Ambient temperature -25 ... 70 °C
Connection type terminal compartment
Core cross-section up to 2.5 mm2
Housing material PBT
Sensing face PBT
Photoelectric

Protection degree IP68


sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 247
Inductive proximity switches NBN30+U1+B3B

Order code
Masters and
Gateways

NBN30+U1+B3B

Features
• VariKont ®
Extender, Repeaters
Power Supplies,

• Basic series
• 30 mm not embeddable
• Position of the sensor
head adjustable
• Oscillator monitoring
• NO/NC programmable
Safety at work

• ON/Off delay (disconnect-


able)
• A/B slave with extended
addressing possibility for
up to 62 slaves
Control cabinet
I/O Modules

Programming Instructions
Technical data
Rated operating distance sn 30 mm Adress 00 preset, alterable
via Busmaster
Installation not embeddable
Field application

or programming units
I/O Modules

NO/NC programmable NBN30+U1+B3B IO-Code 0


ID-Code A
Assured operating distance sa 0 ... 24.3 mm
Reduction factor rAl 0.5 Data bit
Reduction factor rCu 0.45 Bit Function
D0 Switching state
Reduction factor rV2A 0.85
Analogue modules

D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 150 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated
Other modules

P1 Switching element function


Operating voltage display LED, green
NO* / NC
Indication of the switching LED, yellow P2 not used
state P3 not used
Fault indication LED, red
*Standard setting
EMC in accordance with EN 60947-5-2
Inductive sensors

Standards EN 60947-5-2
Ambient temperature -25 ... 70 °C
Connection type terminal compartment
Core cross-section up to 2.5 mm2
Housing material PBT
Sensing face PBT
Photoelectric

Protection degree IP68


sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
248 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NBN40+U1+B3B

Order code

Masters and
Gateways
NBN40+U1+B3B

Features
• VariKont ®

Extender, Repeaters
Power Supplies,
• Basic series
• 40 mm not embeddable
• NO/NC programmable
• Position of the sensor
head adjustable
• Oscillator monitoring

Safety at work
• ON/Off delay (disconnect-
able)
• A/B slave with extended
addressing possibility for
up to 62 slaves

Control cabinet
I/O Modules
Programming Instructions
Technical data
Rated operating distance sn 40 mm Adress 00 preset, alterable
via Busmaster
Installation not embeddable

Field application
or programming units

I/O Modules
NO/NC programmable NBN40+U1+B3B IO-Code 0
ID-Code A
Assured operating distance sa 0 ... 32.4 mm
Reduction factor rAl 0.5 Data bit
Reduction factor rCu 0.45 Bit Function
D0 Switching state
Reduction factor rV2A 0.85

Analogue modules
D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 150 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated

Other modules
P1 Switching element function
Operating voltage display LED, green
NO* / NC
Indication of the switching LED, yellow P2 not used
state P3 not used
Fault indication LED, red
*Standard setting
EMC in accordance with EN 60947-5-2

Inductive sensors
Standards EN 60947-5-2
Ambient temperature -25 ... 70 °C
Connection type terminal compartment
Core cross-section up to 2.5 mm2
Housing material PBT
Sensing face PBT
Photoelectric

Protection degree IP68


sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 249
Inductive proximity switches NBB40-FP-B3B-P1

Order code
Masters and

LEDs
Gateways

NBB40-FP-B3B-P1

40
Features
• Rectangular type

7
Extender, Repeaters
Power Supplies,

• Basic series
• 40 mm embeddable
• NO/NC selectable
• ON/Off delay (disconnect- M20 x 1,5

11
Ø5,3
able)
• Oscillator monitoring
Safety at work

• A/B slave with extended


addressing possibility for
80

up to 62 slaves
65
Control cabinet
I/O Modules

LEDs
65

Programming Instructions
Technical data
Adress 00 preset, alterable
Rated operating distance sn 40 mm
via Busmaster
Installation embeddable or programming units
Field application
I/O Modules

NO/NC programmable NBB40-FP-B3B-P1 IO-Code 0


ID-Code A
Assured operating distance sa 0 ... 32.4 mm
Reduction factor rAl 0.25 Data bit
Reduction factor rCu 0.23 Bit Function
D0 Switching state
Reduction factor rV2A 0.85
Analogue modules

D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system D3 not used
Operating current Ie 25 mA
Parameter bit
Switching frequency f 0 ... 80 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms activated* / deactivated
Other modules

P1 Switching element function


Operating voltage display LED green NO* / NC
Indication of the switching LED yellow P2 not used
state P3 not used
Fault indication LED red
*Standard setting
Standards EN 60947-5-2
Inductive sensors

Ambient temperature -25 ... 70 °C


Connection type terminal compartment
Core cross-section up to 2.5 mm2
Housing material PBT
Sensing face PBT
Protection degree IP67
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
250 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Inductive proximity switches NB*50-FP-B3B-P1

Order code

Masters and
LEDs

Gateways
NBB50-FP-B3B-P1
NBN50-FP-B3B-P1

40
Features

Extender, Repeaters
Power Supplies,
• Rectangular type
• A/B slave with extended
addressing possibility for
up to 62 slaves M20 x 1,5

11
Ø5,3
• NO/NC selectable
• ON/Off delay (disconnect-

Safety at work
able)
• Oscillator monitoring
80

• Basic series
65

• 50 mm embeddable
• 50 mm not embeddable

Control cabinet
I/O Modules
LEDs
65

Programming Instructions
Technical data
Adress 00 preset, alterable
Rated operating distance sn 50 mm 50 mm
via Busmaster
Installation embeddable not embeddable or programming units

Field application
I/O Modules
NO/NC programmable NBB50-FP-B3B-P1 NBN50-FP-B3B-P1 IO-Code 0
ID-Code A
Assured operating distance sa 0 ... 40.5 mm 0 ... 40.5 mm
Reduction factor rAl 0.38 0.4 Data bit
Reduction factor rCu 0.35 0.3 Bit Function
D0 Switching state
Reduction factor rV2A 0.83 0.85

Analogue modules
D1 not used
Operating voltage UB 26.5 ... 31.9 V via AS-i 26.5 ... 31.9 V via AS-i D2 Oscillator monitoring
bus system bus system D3 not used
Operating current Ie 25 mA 25 mA
Parameter bit
Switching frequency f 0 ... 80 Hz 0 ... 80 Hz Bit Function
Hysteresis H 1 ... 15 typ. 5 % 1 ... 15 typ. 5 % P0 ON / Off delay
Time delay before availability tv ≤ 1000 ms ≤ 1000 ms activated* / deactivated

Other modules
P1 Switching element function
Operating voltage display LED green LED green NO* / NC
Indication of the switching LED yellow LED yellow P2 not used
state P3 not used
Fault indication LED red LED red
*Standard setting
Standards EN 60947-5-2 EN 60947-5-2

Inductive sensors
Ambient temperature -25 ... 70 °C -25 ... 70 °C
Connection type terminal compartment terminal compartment
Core cross-section up to 2.5 mm2 up to 2.5 mm2
Housing material PBT PBT
Sensing face PBT PBT
Protection degree IP67 IP67
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders

Electrical connection:

B3B
1 / BN
Accessories

+
I 2
A S-i
3 / BU
-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 251
AS-Interface sensor PL1-F25-B3-K

Order code
Masters and
Gateways

PL1-F25-B3-K 34

21,5
58 11,5
Features
• Pcb version

7
Extender, Repeaters
Power Supplies,

• For installation in housing


LED

• Pluggable cage clamp ter- Sensor2 Sensor1

Sensor1
Sensor2
0 15
15 30
30

minals

4
4

5
˚ 45
45 ˚

• PL1... with valve connec- R2


0 ,8
LED
tion

81

92
• 4-way LED indicator
Safety at work

• Satisfies machinery direc- V

tive
PROG 1 2

1 2 3 4

29
S
67
Control cabinet
I/O Modules

Technical data
Rated operating distance sn 3 mm
Installation embeddable
Field application
I/O Modules

programmable PL1-F25-B3-K
Assured operating distance sa 0 ... 2.43 mm
Reduction factor rAl 0.5
Reduction factor rV2A 1
Reduction factor rSt37 1.1
Analogue modules

Rated operational voltage Ue 26.5 ... 31.6 V from


AS-Interface
Rated operational current Ie 100 mA
Switching frequency f 0 ... 100 Hz
LED ENERGY AS-i voltage; LED
green
Other modules

LED IN switching state (input);


LED yellow
LED OUT switching state (out-
put); LED yellow
Standards EN 60947-5-2
Inductive sensors

Ambient temperature -25 ... 70 °C


Material
Housing PBT
Connection (system side) 4-pin CombiCon con-
nector
Connection (valve side) 2-pin CombiCon con-
nector
Photoelectric
sensors

Protection degree IP20


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders

Electrical connection:
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
252 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface sensor NCN3-F31-B3B-V1-K

Order code

Masters and
Gateways
NCN3-F31-B3B-V1-K
65

Features I

• Rectangular type

33,5
9

Extender, Repeaters
25

Power Supplies,
• A/B slave with extended II

14
addressing possibility for

5
up to 62 slaves 5,4

• Direct mounting on stand-


M12x1

LED
ard actuators
• Nominal sensing range 3 V S
mm by V2A target

Safety at work
• Mode of operation, pro-
grammable
36

• Lead breakage and short-


7

circuit monitoring of the


valve 30

Control cabinet
I/O Modules
Programming Instructions
Technical data
Address 00 preset , alterable
Rated operating distance sn 3 mm via Busmaster or
programming units
Installation embeddable

Field application
IO-code D

I/O Modules
programmable NCN3-F31-B3B-V1-K ID-code A
Assured operating distance sa 0 ... 2.43 mm Data bit
Reduction factor rAl 0.5
Bit function
Reduction factor rCu 0.45
Reduction factor rV2A 1 D0 valve status

Analogue modules
(0=valve OFF; 1=valve ON)
Reduction factor rSt37 1.2
Rated operational voltage Ue 26.5 ... 31.6 V from D1 valve fault 1)
AS-Interface (0=lead breakage/short circuit;
1=no fault)
Rated operational current Ie 100 mA
Switching frequency f 0 ... 100 Hz D2 switch output sensor 1 2)
(0=damped; 1=undamped)
No-load supply current I0 ≤ 35 mA

Other modules
LED PWR AS-i voltage; LED D3 switch output sensor 2 2)
green (0=damped; 1=undamped)

LED IN switching state (input); Parameter bit


LED yellow
Bit function
LED OUT binary LED yellow/red

Inductive sensors
yellow: switching state P0 Watchdog (0= inactive; 1=active)3)
red: lead breakage/ 4)
P1 switching element function sensor II
short-circuit (0=NO; 1=NC)
Ambient temperature -25 ... 70 °C
P2 switching element function sensor I
Material (0=NO; 1=NC)
Housing PBT
P3 not used
Connection (system side) V1-connector
Photoelectric

1)
sensors

Connection (valve side) 0.5 m, PVC cable Verification only with actuated valve (D0=1)
2)
Core cross-section (valve side) 0.75 mm2 Applies to NC function (P2/P3=1; preset),
with NO function (P2/P3=0) reversed characteristics
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Protection degree IP67 3)


Watchdog active: valve voltage drops
Note valve voltage limited to with the occurrence of an AS-I communication fault
4)
26,4 V max.; valve Default setting: NC
Rotary encoders

power 2,5 W max.

Electrical connection:
B3B-V1-K

I A2 S-I
1
S +
Accessories

I 3
-
II

2 / RD
V
V+
4 / YE
V-

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 253
AS-Interface - Photoelectric sensors
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
254 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Photoelectric sensors

7 Photoelectric AS-Interface Sensors

Masters and
Gateways
Photoelectric sensors play a central role today when the goal is to detect or monitor objects without touching them.
They are used wherever various objects must be positioned, classified, or counted.
The applications range from the automobile industry, machine design, and assembly automation to warehousing

Extender, Repeaters
and conveyor systems, packaging machines, the printing and paper industries, the textile industry, and safety sys-

Power Supplies,
tems.
Various versions of the photoelectric sensors with AS-Interface interface are available. These include rectangular
housings with terminal box or M12 connectors, and also VariKont M housings.
One particular feature is the support of the new specification 2.1 of the bus protocol. For the first time, there is a
line of photoelectric sensors for this extended standard. One of the most important changes is the doubling of the

Safety at work
number of AS-Interface slaves which one master can control, from 31 to 62, which significantly increases the at-
traction of the AS-Interface.

Operating principle Type code Series Feature Page

Control cabinet
I/O Modules
Through-beam sensor

LDL28/LV28-LAS-F1-B3B/73c Series 28 Laser light, Spec. 2.1 264

Field application
I/O Modules
Retro-reflective sensor RL28-55-B3B/73c Series 28 Polarization filter, Spec. 2.1 256

OCS3000-M1A-B3 VariKont M Polarization filter 270

OCS3000-M1A-B3-V1 VariKont M Polarization filter 270

Analogue modules
Retro-reflective sensors with
foreground suppression
Polarization filter and foreground
RL28-55-V-B3B/73c Series 28 256
supression, Spec. 2.1

Other modules
Reflective sensors
OCT500-M1A-B3 VariKont M 266

OCT500-M1A-B3-V1 VariKont M 266

Inductive sensors
Reflective sensors with back-
ground suppression RL28-8-H-400-RT-B3B/73c Series 28 Background suppression 262

RL28-8-H-700-RT-B3B/73c Series 28 Background suppression 262


Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 255
RL28-55-B3B/73c

Reflection light beam switch with polarisation filter RL28-55-B3B/73c


Dimensions
Masters and
Gateways

Connector view
4

2 3
54.3
Extender, Repeaters

14.8
U
Power Supplies,

®
Print SW 8
Type code
Connection diagram ø5 25.8

16
Emitter

17.8
62
Receiver

88
Safety at work

11
9.8

25
4

2
10
M12 x 1 Dovetail mount

Order code 10
Control cabinet

51.8
RL28-55-B3B/73c
I/O Modules

Sensitivity adjuster

Reflection light beam switch with polar- LED indicator: switching state LED indicator:
isation filter switching state

LED indicator:
operation/error

Features Technische
Technical data
Daten
Field application
I/O Modules

• Sensor with AS interface according to

RL28-55-B3B/73c
Spec. 2.11
• Ultra bright LEDs for power on, stabil-
ity control and switching state
Analogue modules

• Not sensitive to ambient light, even Effective detection range 0 ... 12 m !


Threshold detection range 16 m !
with switched energy saving lamps !
Reflector distance 0.05 ... 12 m
• Waterproof, protection class IP67 Reference target H85 reflector !
Light type red, alternating light !
• Protection class II Light source LED, 660 nm !
Diameter of the light spot approx. 270 mm at a distance of 16 m !
Angle of divergence emitter 1.2° !
receiver 2°
Other modules

Ambient light limit 80000 Lux !


Approvals CE !
USA UL !
Kanada UL !
Operating display dual-LED green/red !
green: AS-Interface voltage, normal operation
red: communication error or address 0
red/green flashing: Peripherie fault
Inductive sensors

Function display LED yellow: !


1. LED lits constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Operating elements sensitivity adjuster (Adjustment to < 25% of the effective operating range) !
Operating voltage 26.5 ... 31.6 V via AS-Interface network , min. 18.5 V !
No-load supply current ≤ 40 mA !
Protection class II, rated insulation voltage ¡Ü 230 V AC with degree of pollution 1-2 according to IEC !
60664-1
Signal output AS-Interface !
Photoelectric

Switching type Light/dark ON, switchable via AS-i bus system !


sensors

Switching frequency 1000 Hz !


Response time 0.5 ms !

Electrical connection Timer function


Output of the pre-fault indica-
Impulsed off-delay IAB, 50 ms, switchable via AS-Interface
data bit D1:
!
!
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

tion 0: stability control is falling for for approx. 10 s (LED yellow is flashing) or at once 0 after
Option AS-Interface the 4. light beam interruptionch during the flashtimet
1: sufficient stability control
Rotary encoders

Test input Data bit D2: !


1 +
0: emitter on
1: emitter off
Standards EN 60947-5-2 EN 50295 AS-i Complete Spec 2.11 !
Ambient temperature -40 ... 60 °C (233 ... 333 K) !
Storage temperature -40 ... 75 °C (233 ... 348 K) !
Protection degree IP67 !
3 - !
Connection Plastic connector M12 x 1, 4-pin
Housing Plastic ABS !
Optical face plastic !
Accessories

Mass 70 g !

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
256 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
RL28-55-B3B/73c Diagrams/notes

Characteristic response curve RL28-55; RLK28-55

Masters and
Gateways
Offset Y [mm]
180
160
140
120

Extender, Repeaters
100

Power Supplies,
80
60
40
20
0
0 5 10 15 20
H85 Distance X [m]

Safety at work
x C110-2
H60
H160
y

F2000

RL28-55; RLK28-55
Relative received light strength
Reflector type:

Control cabinet
H85 (80 mm x 80 mm)

I/O Modules
50 mm 16 m

C110_2 (ø = 84 mm) 50 mm 14 m

H60 (60 mm x 40 mm) 50 mm 12 m

F2000 (Foil, 100 mm x 100 mm) 250 mm 10 m

Field application
I/O Modules
H160 (60 mm x 18 mm) 50 mm 5m

Stability control
1000
Stability control > 3

Stability control < 3


H85

Analogue modules
C110-2
100 H60
H160
F2000

10

Other modules
1
x
0 5 10 15 20
Distance X [m]

AS-Interface programming

Inductive sensors
<F id="261">Address preset to 00, can be changed via Busmaster or programming devices
IO-Code 3
ID-Code A
ID2 1

• Data bit
<F id="263">Bitfunction
D0 Switch output (0=light beam free, 1=light beam interrupted) applies to P1=0
D1 Pre-fault indicator (0=alarm, 1=no alarm)
Photoelectric

D2 Test function (0=emitter ON, 1=emitter OFF)


sensors

D3 not used
• Parameter bit
<F id="263">Bitfunction (1/0)
P0 not used
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P1 Light/dark-changeover switch (0=DS, 1=HS)


P2 Time function IAB, 50 ms (0=time ON, 1=time OFF)
P3not used
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 257
RL28-55-V-B3B/73c

Reflection light beam switch with polarisation filter RL28-55-V-B3B/73c


Dimensions
Masters and
Gateways

Connector view
4

2 3
54.3
Extender, Repeaters

14.8
U
Power Supplies,

®
Print SW 8
Type code
Connection diagram ø5 25.8

16
Emitter

17.8
62
Receiver

88
Safety at work

11
9.8

25
4

2
10
M12 x 1 Dovetail mount

Order code 10
Control cabinet

51.8
RL28-55-V-B3B/73c
I/O Modules

Sensitivity adjuster

Reflection light beam switch with polar- LED indicator: switching state LED indicator:
isation filter with foreground suppres- switching state

LED indicator:
sion operation/error

Features Technische
Technical data
Daten
Field application
I/O Modules

• Sensor with AS interface according to

RL28-55-V-B3B/73c
Spec. 2.11
• Foreground suppression, suited to
recording of sheet-shrink-wrapped
Analogue modules

objects
Effective detection range 0 ... 9 m !
• Ultra bright LEDs for power on, stabil- Threshold detection range 12 m !
ity control and switching state Reflector distance 0.5 ... 9 m (blind range 0 ... 0.2 m faded out) !
Reference target H85 reflector !
• Not sensitive to ambient light, even Light type red, alternating light !
with switched energy saving lamps Light source LED, 660 nm !
Diameter of the light spot approx. 200 mm at a distance of 12 m !
• Waterproof, protection class IP67 Angle of divergence emitter 1.2° !
Other modules

receiver 2°
• Protection class II Ambient light limit 80000 Lux !
Approvals CE !
USA UL !
Kanada UL !
Operating display dual-LED green/red !
green: AS-Interface voltage, normal operation
red: communication error or address 0
Inductive sensors

red/green flashing: Peripherie fault


Function display LED yellow: !
1. LED lits constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Operating elements sensitivity adjuster (Adjustment to < 25% of the effective operating range) !
Operating voltage 26.5 ... 31.6 V via AS-Interface network , min. 18.5 V !
No-load supply current ≤ 40 mA !
Protection class II, rated voltage ≤ 250 V AC with degree of pollution 1-2 according to IEC 60664-1 !
Signal output AS-Interface !
Photoelectric

Switching type Light/dark ON, switchable via AS-i bus system !


sensors

Switching frequency 1000 Hz !


Response time 0.5 ms !
Timer function Impulsed off-delay IAB, 50 ms, switchable via AS-Interface !
Electrical connection Output of the pre-fault indica- data bit D1: !
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

tion 0: stability control is falling for for approx. 10 s (LED yellow is flashing) or at once 0 after
Option AS-Interface the 4. light beam interruptionch during the flashtimet
1: sufficient stability control
Rotary encoders

Test input Data bit D2: !


1 + 0: emitter on
1: emitter off
Standards EN 60947-5-2 EN 50295 AS-i Complete Spec 2.11 !
Ambient temperature -40 ... 60 °C (233 ... 333 K) !
Storage temperature -40 ... 75 °C (233 ... 348 K) !
Protection degree IP67 !
3 - Connection Plastic connector M12 x 1, 4-pin !
Housing Plastic ABS !
Optical face plastic !
Accessories

Mass 70 g !

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
258 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
RL28-55-V-B3B/73c Diagrams/notes

Characteristic response curve RL28-55-V

Masters and
Gateways
Offset Y [mm]
180
160
140
120

Extender, Repeaters
100

Power Supplies,
80
60
40
20
0
0 2 4 6 8 10
H85 Distance X [m]

Safety at work
x C110-2
H60
H160
y

F2000

RL28-55-V
Relative received light strength
Reflector type:

Control cabinet
H85 (80 mm x 80 mm)

I/O Modules
500 mm 12,0 m

C110_2 (ø = 84 mm) 500 mm 11,0 m

H60 (60 mm x 40 mm) 600 mm 9,0 m

F2000 (Foil, 100 mm x 100 mm) 900 mm 6,0 m

Field application
I/O Modules
H160 (60 mm x 18 mm) 500 mm 4,5 m

Stability control
100
Stability control > 3

Stability control < 3 H85


C110-2

Analogue modules
H60
H160
F2000

10

Other modules
x 1
0 5 10 15
Distance X [m]

AS-Interface programming

Inductive sensors
<F id="261">Address preset to 00, can be changed via Busmaster or programming devices
IO-Code 3
ID-Code A
ID2 1

• Data bit
<F id="263">Bitfunction
D0 Switch output (0=light beam free, 1=light beam interrupted) applies to P1=0
D1 Pre-fault indicator (0=alarm, 1=no alarm)
Photoelectric

D2 Test function (0=emitter ON, 1=emitter OFF)


sensors

D3 not used
• Parameter bit
<F id="263">Bitfunction (1/0)
P0 not used
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P1 Light/dark-changeover switch (0=DS, 1=HS)


P2 Time function IAB, 50 ms (0=time ON, 1=time OFF)
P3not used
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 259
RL28-55-LAS-B3B/73c

Reflection light beam switch with polarisation filter RL28-55-LAS-B3B/73c


Dimensions
Masters and
Gateways

Connector view
4

2 3
54.3
Extender, Repeaters

14.8
Power Supplies,

Print SW 8
Type code
Connection diagram ø5 25.8

16
Emitter

17.8
62
Receiver

88
Safety at work

Laser Class II

11
9.8

25
4

2
10
M12 x 1 Dovetail mount

Order code 10
Control cabinet

51.8
RL28-55-LAS-B3B/73c
I/O Modules

Sensitivity adjuster

Reflection light beam switch with polar- LED indicator: switching state LED indicator:
isation filter switching state

LED indicator:
operation/error

Features Technische
Technical data
Daten
Field application
I/O Modules

• Sensor with AS interface according to

RL28-55-LAS-B3B/73c
Spec. 2.11
• Ultra bright LEDs for power on, stabil-
ity control and switching state
Analogue modules

• Visible red light, pulsed LASER light


• Not sensitive to ambient light, even Effective detection range 0 ... 30 m !
Threshold detection range 42 m (with reflector MH82) !
with switched energy saving lamps Reflector distance 0.3 ... 30 m !
!
• Protection class II Reference target MH82 reflector
Light type red, alternating light !
Light source laser diode , 650 nm !
Optical power output < 1 mW !
Other modules

Laser class 2 !
Diameter of the light spot approx. 45 mm at 30 m !
Angle of divergence emitter: < 0.1 ° Receiver: < 2 ° !
Transmitter frequency approx. 6 kHz ... 20 kHz !
Ambient light limit 50000 Lux !
Approvals CE !
Operating display dual-LED green/red !
green: AS-Interface voltage, normal operation
Inductive sensors

red: communication error or address 0


red/green flashing: Peripherie fault
Function display LED yellow: !
1. LED lits constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Operating elements sensitivity adjuster (Adjustment to < 25% of the effective operating range) !
Operating voltage 26.5 ... 31.6 V via AS-Interface network , min. 18.5 V !
No-load supply current ≤ 40 mA !
Protection class II, rated insulation voltage ¡Ü 230 V AC with degree of pollution 1-2 according to IEC !
Photoelectric

60664-1
sensors

Signal output AS-Interface !


Switching type Light/dark ON, switchable via AS-i bus system !
Switching frequency 1000 Hz !
Electrical connection Response time 0.5 ms !
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Timer function Impulsed off-delay IAB, 50 ms, switchable via AS-Interface !

Option AS-Interface Output of the pre-fault indica- data bit D1: !


tion 0: stability control is falling for for approx. 10 s (LED yellow is flashing) or at once 0 after
Rotary encoders

the 4. light beam interruptionch during the flashtimet


1 + 1: sufficient stability control
Test input Data bit D2: !
0: emitter on
1: emitter off
Standards EN 60947-5-2 EN 50295 AS-i Complete Spec 2.11 !
Ambient temperature -10 ... 50 °C (263 ... 323 K) !
3 - Storage temperature -20 ... 75 °C (253 ... 348 K) !
Protection degree IP67 !
Connection Plastic connector M12 x 1, 4-pin !
Accessories

Housing Plastic ABS !


Optical face Plastic lens !
Mass 80 g !

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
260 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
RL28-55-LAS-B3B/73c Diagrams/notes

Light spot diameter = f (Distance) RL(K)28-55-LAS

Masters and
Gateways
Diameter in mm
80

70

60

Extender, Repeaters
50

Power Supplies,
40

30

20

10

0
0 10 20 30 40 50
Distance in m

Safety at work
x

RL(K)28-55-LAS...
Relative received light strength
Reflector type:

Control cabinet
I/O Modules
MH82 0.3 mm
0,3 42 m

MH78 0.3 mm
0,3 42 m

H60 0.3 mm
0,3 42 m

Field application
I/O Modules
Stability control
20

Stability control > 2


MH82
Stability control < 2 15 MH78
H60

Analogue modules
10

Other modules
2

x 0
0 5 10 15 20 25 30 35 40 45
Distance X [m]

AS-Interface programming

Inductive sensors
<F id="261">Address preset to 00, can be changed via Busmaster or programming devices
IO-Code 3
ID-Code A
ID2 1

• Data bit
<F id="263">Bitfunction
D0 Switch output (0=light beam free, 1=light beam interrupted) applies to P1=0
D1 Pre-fault indicator (0=alarm, 1=no alarm)
Photoelectric

D2 Test function (0=emitter ON, 1=emitter OFF)


sensors

D3 not used
• Parameter bit
<F id="263">Bitfunction (1/0)
P0 not used
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P1 Light/dark-changeover switch (0=DS, 1=HS)


P2 Time function IAB, 50 ms (0=time ON, 1=time OFF)
P3not used
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 261
RL28-8-H-400-RT-B3B/73c

Reflection light scanner with background suppression RL28-8-H-...-RT-B3B/73c


Dimensions
Masters and
Gateways

Connector view
4

2 3
54.3
Extender, Repeaters

14.8
U
Power Supplies,

®
Print SW 8
Type code
Connection diagram ø5 25.8

16
Emitter

26.5
62
88
Receiver
Safety at work

11
9.8

25
10 4

2
M12 x 1 Dovetail mount

Order code 10
Control cabinet

51.8
RL28-8-H-...-RT-B3B/73c
I/O Modules

Sensing range adjuster

Reflection light scanner with back- LED indicator: switching state LED indicator:
ground suppression switching state

LED indicator:
operation/error

Features Technische
Technical data
Daten
Field application
I/O Modules

• Sensor with AS interface according to

RL28-8-H-400-RT-B3B/73c

RL28-8-H-700-RT-B3B/73c
Spec. 2.11
• Ultra bright LEDs for power on and
switching state
Analogue modules

• Good alignability due to red transmis-


sion LED
!
• Not sensitive to ambient light, even Detection range 20 ... 400 mm
20 ... 700 mm !
with switched energy saving lamps Detection range min. 20 ... 150 mm !
20 ... 200 mm !
• Waterproof, protection class IP67 !
Sensor range max. 20 ... 400 mm
• Protection class II 20 ... 700 mm !
Other modules

Black/White difference (6 < 10 % !


%/90 %)
< 20 % !
Background suppression max. + 10 % of the upper limit of the detection range ! !
Light type red, alternating light ! !
Light source LED, 660 nm ! !
Diameter of the light spot approx. 12 mm at a distance of 400 mm !
approx. 15 mm at a distance of 700 mm !
Inductive sensors

Angle of divergence Emitter 1.2°, ! !


Receiver 2°
Ambient light limit 50000 Lux ! !
Approvals CE ! !
USA UL ! !
Kanada UL ! !
Operating display dual-LED green/red ! !
green: AS-Interface voltage, normal operation
red: communication error or address 0
red/green flashing: Peripherie fault
Photoelectric

Function display 2 LEDs yellow ! !


sensors

on: object inside the scanning range


off: object outside the scanning range
Operating elements sensing range adjuster !
Electrical connection Operating voltage 26.5 ... 31.6 V via AS-Interface network , min. 18.5 V ! !
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

No-load supply current ≤ 40 mA ! !


Option AS-Interface Protection class II, rated voltage ≤ 250 V AC with degree of pollution 1-2 according to IEC 60664-1 ! !
Caution!
Rotary encoders

The protection class 2 is only valid when the terminal compartment is closed.
1 + Signal output AS-Interface ! !
Switching type Light/dark ON, switchable via AS-i bus system ! !
Switching frequency 250 Hz ! !
Response time 2 ms ! !
Timer function Impulsed off-delay IAB, 50 ms, switchable via AS-Interface ! !
Test input Data bit D2: 0: emitter on, 1: emitter off ! !
3 - ! !
Standards EN 60947-5-2 EN 50295 AS-i Complete Spec 2.11
Ambient temperature -40 ... 60 °C (233 ... 333 K) ! !
Storage temperature -40 ... 75 °C (233 ... 348 K) ! !
Accessories

Protection degree IP67 ! !


Connection Plastic connector M12 x 1, 4-pin ! !
Housing Plastic ABS ! !
Optical face plastic ! !
Mass 70 g ! !

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
262 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
RL28-8-H-...-RT-B3B/73c Diagrams/notes
RL(K)28-8-H-400-RT RL(K)28-8-H-700-RT
Difference in detection distance Difference in detection distance

Masters and
Gateways
Measured detection distance X [mm] Measured detection distance X [mm]
450 800
400 700
350 600
300
500

Extender, Repeaters
250

Power Supplies,
400
200
300
150
100 200

50 100
0 0
0 100 200 300 400 500 0 200 400 600 800
Adjusted detection distance X [mm] Adjusted detection distance X [mm]

Safety at work
x white 90 % x white 90 %
grey 18 % grey 18 %
black 6 % black 6 %

Characteristic response curve RL(K)28-8-H-400-RT Characteristic response curve RL(K)28-8-H-700-RT

Offset Y [mm] Offset Y [mm]

Control cabinet
6

I/O Modules
8
6
4
4
2
2

0 0

-2

Field application
-2

I/O Modules
-4
-4
-6

-6 -8
0 100 200 300 400 500 0 200 400 600 800
Distance X [mm] Distance X [mm]
x x

Analogue modules
white 90 % white 90 %
grey 18 % grey 18 %
y

black 6 % black 6 %

Other modules
AS-Interface programming

Inductive sensors
<F id="261">Addresspreset to 00, can be changed via Busmaster or programming devices
IO-Code 3
ID-Code A
ID2 1

• Data bit
<F id="263">Bitfunction
D0 Switch output (0=object detected, 1=no object detected) applies to P1=0
D1 not used
Photoelectric

D2 Test function (0=emitter ON, 1=emitter OFF)


sensors

D3 not used
• Parameter bit
<F id="263">Bitfunction (1/0)
P0not used
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P1 Light/dark-changeover switch (0=DS, 1=HS)


P2 Time function IAB, 50 ms (0=time ON, 1=time OFF)
P3 not used
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 263
LD28/LV28-LAS-F1-B3B/73c

Single path light beam switch LD28/LV28-LAS-F1-B3B/73c


Dimensions
Masters and
Gateways

Emitter Receiver
"Z"
1
"Z"
2 4

3
Extender, Repeaters

14.8
Power Supplies,

SW8

54.3 ø5 25.8

16
LED-indicator red

24
62
alignment aid

88
Dovetail mount

nicht in den Strahl blicken


Leser Klasse 2

Laserstrahlung
5

11
Safety at work

25

4
Laser Class II

2
Additional label only
at version -LAS (2x) 9.6

10
10 M12x1

51.8
LED indicator:
switching state

Order code LED indicator:


Control cabinet

switching state
LD28/LV28-LAS-F1-B3B/73c
I/O Modules

Single path light beam switch Sensitivity adjuster


LED indicator:
operation/error

Features Technische
Technical data
Daten
Field application
I/O Modules

• Sensor with AS interface according to

LD28/LV28-LAS-F1-B3B/73c
Spec. 2.11
• Ultra bright LEDs for power on, stabil-
ity control and switching state
Analogue modules

• Very clearly visible LED as alignment


aid in receiver optics
• Visible red light, pulsed LASER light Effective detection range 0 ... 300 m !
Threshold detection range 400 m !
• Not sensitive to ambient light, even !
Light type red, alternating light, < 1 mW
with switched energy saving lamps Light source laser diode , 650 nm !
Laser class 2 !
• Waterproof, protection class IP67 !
Other modules

Diameter of the light spot approx. 1 mm x 4.5 mm at 0.1 m approx. 6 mm at 5 m, approx. 75 x 300 mm at 300 m ver-
• Protection class II tical to housing axis
Beam divergence ≤ 1 mrad !
Angle of divergence emitter: 0.06 ° !
Receiver: 5 °
Transmitter frequency F1 = 25 kHz !
Ambient light limit 50000 Lux !
Alignment aid LED red (in receiver lens) !
illuminated constantly: beam is interrupted,
Inductive sensors

flashes: reaching switching point,


off: sufficient stability control
Approvals CE !
Operating display LED green !
Function display LED yellow: !
1. LED lits constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Operating elements sensitivity adjuster (Adjustment to < 25% of the effective operating range) !
Operating voltage 26.5 ... 31.6 V via AS-Interface network , min. 18.5 V !
Photoelectric

No-load supply current emitter: ≤ 55 mA !


sensors

Receiver: ≤ 45 mA
Protection class II , rated voltage ≤ 250 V AC with degree of pollution 1-2 according to IEC 60664-1 !
Electrical connection Signal output AS-Interface !
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Switching type Light/dark ON, switchable via AS-i bus system !


Switching frequency 1000 Hz !
Option AS-Interface
Response time 0.5 ms !
Timer function Impulsed off-delay IAB, 50 ms, switchable via AS-Interface !
Rotary encoders

1 + Output of the pre-fault indica- data bit D1: !


tion 0: stability control is falling for for approx. 10 s (LED yellow is flashing) or at once 0 after
the 4. light beam interruptionch during the flashtimet
1: sufficient stability control
Test input Data bit D2: !
0: emitter on
3 - 1: emitter off
Standards EN 60947-5-2 EN 50295 AS-i Complete Spec 2.11 !
Ambient temperature -10 ... 50 °C (263 ... 323 K) !
Accessories

Storage temperature -20 ... 75 °C (253 ... 348 K) !


Protection degree IP67 !
Connection Plastic connector M12 x 1, 4-pin !
Housing Plastic ABS !
Optical face Plastic lens !
Mass 140 g (emitter and receiver) !

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
264 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
LD28/LV28-LAS-F1-B3B/73c Diagrams/notes
LD28/LV28-LAS; LD28/LV28-LAS;
Characteristic response curve LA28/LK28-LAS
Relative received light strength LA28/LK28-LAS

Masters and
Gateways
Stability control
Offset Y [mm] 1000
60
50
40
30 100
20

Extender, Repeaters
10

Power Supplies,
0
-10
-20 10
-30
-40
-50
-60
1
0 100 200 300 400 0 100 200 300 400
x Distance X [m] Distance X [m]

Safety at work
Permissible distance (offset)
x
between the optical axis of
y

the emitter and receiver.

Light spot diameter = f (Distance) LD28/LV28-LAS;


LA28/LK28-LAS

Control cabinet
Diameter in mm

I/O Modules
100

10

Field application
I/O Modules
1
0 100 200 300 400
Distance in m

Analogue modules
x

Other modules
AS-Interface programming

Inductive sensors
<F id="261">Addresspreset to 00, can be changed via Busmaster or programming devices
IO-Code 3
ID-Code A
ID2 1

Receiver:
• Data bit
<F id="263">Bitfunction
D0 Switch output (0=light beam free, 1=light beam interrupted) applies to P1=0
Photoelectric

D1 Pre-fault output (0=alarm, 1=no alarm)


sensors

D2 not used
D3 not used
• Parameter bit
<F id="263">Bitfunction
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P0 not used
P1 Light/dark-changeover switch (0=DS, 1=HS)
P2 Time function IAB, 50 ms (0=time ON, 1=time OFF)
Rotary encoders

P3 not used

Emitter
• Data bit
<F id="263">Bitfunction
D0 not used
D1 not used
D2 Test function (0=emitter ON, 1=emitter OFF)
D3 not used
Accessories

• Parameter bit
<F id="263">Bitfunction
P0 not used
P1 not used
P2 not used
P3 not used

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 265
OCT500-M1A-B3

Reflection light scanner OCT500-M1A-B3-..


Dimensions
Masters and
Gateways

100
91 Optical axis
Extender, Repeaters

ø25.5
Power Supplies,

30

15
15
Terminal compartment 15
59
30
Sensitivity adjuster 20 4.3 x 5.3 LED

Plug design V1

M16
6
(M12 x 1)
Safety at work

20/22
30
3

10
2 4

4
41 1

Terminal compartment

Order code
Control cabinet

M12 x 1
4

2
OCT500-M1A-B3-..
I/O Modules

1
Reflection light scanner
111

Features Technische
Technical data
Daten
Field application
I/O Modules

• Light/dark ON parameterisable

OCT500-M1A-B3-V1
OCT500-M1A-B3
• AS-Interface certificate
• Pre-fault indication (dynamic, static)
• Protected against mutual interference
Analogue modules

• Removable terminal compartment Detection range without light guide : 0 ... 500 mm , with light guide see selection table for fibre optics ! !
Detection range min. 0 ... 40 mm ! !
• Position of the sensor head adjusta- Sensor range max. 0 ... 500 mm ! !
ble Reference target standard white 200 mm x 200 mm ! !
Light type infrared, alternating light ! !
• For glass fibre light guide Light source LED ! !
Ambient light limit 40000 Lux ! !
Approvals CE ! !
Other modules

Operating display LED green ! !


Function display LED yellow: switching state ! !
LED red: stability control (flashing)
Operating elements sensing range adjuster !
Operating voltage via AS-Interface network ! !
Ripple 10 % ! !
No-load supply current ≤ 40 mA ! !
Time delay before availability ≤ 20 ms ! !
Inductive sensors

Signal output AS-Interface ! !


Switching type light/dark switching ! !
Switching frequency ≤ 1.5 kHz / 200 Hz switchable ! !
Response time ≤ 0.3 ms at 1.5 kHz ≤ 2.5 ms at 200 Hz ! !
Timer function pulse extension 20 ms, configurable ! !
Output of the pre-fault indica- data bit D1 (not at 1.5 kHz) ! !
tion
Standards EN 60947-5-2 ! !
Ambient temperature -25 ... 70 °C (248 ... 343 K) ! !
Storage temperature -40 ... 80 °C (233 ... 353 K) ! !
Photoelectric

Protection degree IP67 ! !


sensors

Connection connector M12 x 1, 4-pin !


terminal compartment M16, core cross-section ≤ 2,5 mm2 !

Electrical connection Material


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Housing PBT ! !
Optical face Scratch resistant mineral glass lens ! !
Option AS-Interface Mass 100 g ! !
Rotary encoders

1 +

3 -
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
266 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
OCT500-M1A-B3-.. Diagrams/notes
OCT 500-M1K
Characteristic response curve Detection ranges

Masters and
Gateways
Object colour
Offset Y [mm]

20
10 Black

Extender, Repeaters
-10

Power Supplies,
Grey
-20
-30
-40
-50 White
0 100 200 300 400 500 600 700
Distance X [mm]
0 100 200 300 400 500 600
X
Permissible distance (offset) Distance X [mm]

Safety at work
between optical axis and object.
x
-Y Y

Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
AS-Interface programming

Inductive sensors
Address preset to 00, can be changed via Busmaster or programming devices
IO code 1
ID code 1
• Data bit
Bit Function
D0 switch output
D1 pre-fault indication (0=ON, 1=OFF)
D2 ready to operate
Photoelectric

D3 switching frequency 200 Hz*/1.5 kHz3)


sensors

• Parameter bit
Bit Function (1/2)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P0 pulse frequency 1*/2


P1 switch output, light*/dark ON
P2 pulse extension (20 ms) OFF*/ON
Rotary encoders

P3 pre-fault indication3) dynamic*/static


3)No
* Default setting activation of pre-fault signal at 1.5 kHz.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 267
Reflection light scanner OCT500-M1A-B3-..

Selection table for fibre


Masters and
Gateways

Model number Range in mm Detection range in mm Fig.


single path with

LCE 18-2,3-0,5-K2 600 1


PVC coating
fibre optic,
Extender, Repeaters
Power Supplies,

LCE 18-2,3-0,5-K9 600 4

LME 18-1,9-0,5-K9 500 4


LME 18-2,3-0,5-K10 600 5
Safety at work

single path with


metal coating
fibre optic,

LME 18-2,3-0,5-K2 600 1


LME 18-2,3-0,5-K3 600 2
LME 18-2,3-0,5-K4 600 3
LME 18-2,3-1,0-K2 600 1
LME 18-2,3-2,0-K2 600 1
Control cabinet
I/O Modules

single path with silicon


Glass fibre optics,

coating

LSE 18-1,1-0,5-K9 100 4


Field application
I/O Modules

LCR 18-2,7-1,0-K9 75 12
LCR 18-3,2-0,5-K1 100 6
PVC coating
fibre optic,
reflex with
Analogue modules

LCR 18-3,2-0,5-K2 100 7


LCR 18-3,2-2,0-K2 100 7
LMR 18-1,1-0,5-K3 10 8
LMR 18-2,3-0,25-K3 45 8

LMR 18-2,3-0,5-K2 45 7
Other modules

LMR 18-2,3-0,5-K3 45 8
LMR 18-2,3-0,5-K7 45 11
Glass fibre optics, reflex

LMR 18-2,7-0,5-K9 75 12
with metal coating

LMR 18-3,2-0,5-K1 100 6


LMR 18-3,2-0,5-K5 100 10
Inductive sensors

LMR 18-3,2-1,0-K1 100 6


LMR 18-3,2-1,0-K5 100 10
LMR 18-3,2-2,0-K1 100 6
LMR 18-3,2-2,0-K4 100 9
LMR 18-3,2-3,0-K1 100 6
Photoelectric
sensors

silicon coating

LSR 18-2,3-0,5-K12 45 13
fibre optic,
reflex with

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

LSR 18-3,2-0,5-K1 100 6


Rotary encoders

Other lengths and end pieces available on request


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
268 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Reflection light scanner OCT500-M1A-B3-..

Fig. 1 Fig. 8

Masters and
Gateways
M8 x 1
ø 4.5
500/1000/2000
250/500

ø8
M4
20
20
35 Covering: M
35

Extender, Repeaters
Power Supplies,
Covering: P/M

Fig. 2 Fig. 9
500

M10 x 1
ø8
M4

2000

Safety at work
20
35
35 Covering: M

Covering: M

Fig. 3 Fig. 10

Control cabinet
I/O Modules
M10 x 1

M8 x 1
500
500/1000

35
35 Covering: P

Covering: M

Field application
I/O Modules
Fig. 4 Fig. 11

14 500
500
ø8

ø6

Analogue modules
10

35 Covering: M
ø4

Covering: S/M/P

Fig. 5 Fig. 12

Other modules
20 500
ø8

14 500/1000
ø8
10

10

ø6 Covering: P/M
ø4
Covering: M

Inductive sensors
Fig. 6 Fig. 13

500/1000/2000/3000 32 500
ø4.5

ø8

15

20
Covering: P/S/M
Photoelectric

35
32

Covering: P/M
sensors

ø4
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Fig. 7
M8 x 1

Rotary encoders

Adapter
ø4.5

500/2000
21
4.7 5
20
Covering: P/M
35
ø13

65

Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 269
OCS3000-M1A-B3

Reflection light beam switch with polarisation filter OCS3000-M1A-B3-..


Dimensions
Masters and
Gateways

Optical axis Optical axis


receiver emitter
102
Extender, Repeaters
Power Supplies,

30

15
15
Terminal compartment 9
21
59
30 4.3 x 5.3 LED

Plug design V1

M16
(M12 x 1)
Safety at work

20/22
30
3

10
2 4

4
52 1

Terminal compartment

Order code
Control cabinet

M12 x 1
4

2
OCS3000-M1A-B3-..
I/O Modules

1
Reflection light beam switch with polar-
isation filter 111

Features Technische
Technical data
Daten
Field application
I/O Modules

• Light/dark ON parameterisable

OCS3000-M1A-B3-V1
OCS3000-M1A-B3
• AS-Interface certificate
• Visible red light
• Glare protected with polarisation filter
Analogue modules

• Pre-fault indication (dynamic, static) ! !


Effective detection range 0 ... 3000 mm
• Protected against mutual interference Threshold detection range 6m ! !
Reflector distance 200 ... 3000 mm ! !
• Position of the sensor head adjusta- Reference target reflector C110_2 ! !
! !
ble Light type red, alternating light
Light source LED ! !
Ambient light limit 10000 Lux ! !
Approvals CE ! !
Other modules

Operating display LED green ! !


Function display LED yellow: switching state ! !
LED red: stability control (flashing)
Operating voltage via AS-Interface network ! !
Ripple 10 % ! !
No-load supply current ≤ 40 mA ! !
Time delay before availability ≤ 20 ms ! !
Signal output AS-Interface ! !
Inductive sensors

Switching type Light/dark ON, switchable ! !


Switching frequency ≤ 1.5 kHz / 200 Hz parameterisable with ULTRA 2001 ! !
Response time ≤ 0.3 ms at 1.5 kHz , ≤ 2.5 ms at 200 Hz ! !
Timer function pulse extension 20 ms, configurable ! !
Output of the pre-fault indica- data bit D1 (not at 1.5 kHz) ! !
tion
Standards EN 60947-5-2 ! !
Ambient temperature -25 ... 70 °C (248 ... 343 K) ! !
Storage temperature -40 ... 80 °C (233 ... 353 K) ! !
Photoelectric

Protection degree IP67 ! !


!
sensors

Connection connector M12 x 1, 4-pin


terminal compartment M16, core cross-section ≤ 2,5 mm2 !
Material
Electrical connection Housing PBT ! !
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Optical face Scratch resistant mineral glass lens ! !


Mass 100 g ! !
Option AS-Interface
Rotary encoders

1 +

3 -
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
270 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
OCS3000-M1A-B3-.. Diagrams/notes

Characteristic response curve OJ3000-M1K...


OCS3000-M1A...

Masters and
Gateways
Offset Y [mm]
160

140

120

100

Extender, Repeaters
Power Supplies,
80

60

40

20

0
0 1 2 3 4 5
H85 Distance X [m]

Safety at work
x C110-2
H60
H160
y

F2000

Relative received light strength OJ3000-M1K...


OCS3000-M1A...
Reflector type:

Control cabinet
H85 (80 mm x 80 mm)

I/O Modules
200 mm 6.0 m

C110_2 (ø = 84 mm) 200 mm 6.0 m

H60 (60 mm x 40 mm) 200 mm 4.0 m

F2000 (foil, 100 mm x 100 mm) 200 mm 3.5 m

Field application
H160 (60 mm x 18 mm) 200 mm 3.0 m

I/O Modules
Stability control
100
Stability control > 3
H85
Stability control < 3 C110-2
H60

Analogue modules
H160
F2000

10

Other modules
x 1
0 1 2 3 4 5 6 7
Distance X [m]

AS-Interface programming

Inductive sensors
Address preset to 00, can be changed via Busmaster or programming devices
IO code 1
ID code 1
• Data bit
Bit Function
D0 switch output
D1 pre-fault indication (0=ON, 1=OFF)
D2 ready to operate
Photoelectric

D3 switching frequency 200 Hz*/1.5 kHz3)


sensors

• Parameter bit
Bit Function (1/2)
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

P0 pulse frequency 1*/2


P1 switch output, light*/dark ON
P2 pulse extension (20 ms) OFF*/ON
Rotary encoders

P3 pre-fault indication3) dynamic*/static


3)No
* Default setting activation of pre-fault signal at 1.5 kHz.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 271
AS-Interface - Rotary Encoder
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
272 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Rotary Encoder
8 AS-Interface Rotary Encoder

Masters and
Rotary encoders are available in the following ver-

Gateways
In modern machines and systems, binary sensors and
actuators are networked extensively with AS-Inter- sions:
face.
In the past, conventional and expensive wiring tech- Clamping flange

Extender, Repeaters
niques have had to be used for absolute encoders, be-

Power Supplies,
cause handshake operation with the PLC in accord-
ance with the analogue profile proved too slow for po-
sitioning tasks.
In order to meet the real-time demands of many appli-
cations, a multi-slave solution using AS-Interface rota-

Safety at work
ry encoders was created. In this solution, 4 AS-Inter-
face slaves are integrated in a single rotary encoder.
These are preset and allocated to addresses 1 to 4.
This means that a maximum of 16 bits are available for
position coding.
Servo flange

Control cabinet
AS-Interface rotary encoders are available as:

I/O Modules
• Singleturn absolute encoders
• Multiturn absolute encoders
Singleturn absolute encoders have a resolution of 13

Field application
bits. This results in a resolution of 8192 steps per rota-

I/O Modules
tion.
The multiturn absolute encoders use all 16 bits. Vari-
ous combinations of steps per rotation are available to
make up the total number of turns, from 8192 steps

Analogue modules
per rotation with a maximum of 8 rotations (13 bits or
3 bits) to 16 steps per rotation with a maximum of 4096
rotations (4 bits or 12 bits). Blind hole shaft
Independent of whether a singleturn or multiturn abso-
lute encoder is used, the position value is transmitted
to the master and made available to the PLC within a

Other modules
single AS-Interface cycle. A type of bit known as a flag
bit can be transmitted and evaluated to ensure that the
values are from the same cycle.
The type of coding applied to the position value can be
configured as desired. Binary or gray code can be

Inductive sensors
used.

Various types of shaft or flange are available for both


solid shaft and blind hole shaft encoders.
Photoelectric

An extensive range of accessories is available to facil-


sensors

itate installation and integration into individual applica-


tions.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 273
BVS58

Singleturn absolute encoder BVS58

Dimensions
Masters and
Gateways

(93.5)
63.5 ø48 ± 0.1
0.05 A 20 10 3 3


12
0.5 + 0.1
Extender, Repeaters

3x
Power Supplies,

15
A

ø10h7
ø36f8
ø52
ø58
17.5

52.9
Safety at work

3 x M3
0.2 A
7 deep

Clamping flange

Connector V1, radial


Control cabinet

(83.5)
I/O Modules

69.5 ø42 ± 0.1


10 4 3 3
0.05 A
Order code


12
Series BVS58
0.5 + 0.1

3x
See type key code for correct order code A
Field application

ø50h7
I/O Modules

ø58

ø6h7

17.5
Features
52.9
• Industrial standard housing Ø58 mm 3 x M4
0.2 A
Analogue modules

10 deep
• 13 Bit singleturn
Servo flange
• Output code: Gray and binary
• Transfer of position data with 4 AS- Connector V1, radial

Interface slaves
• Parameterisation and addressing via
AS-Interface Function
Other modules

• Servo or clamping flange In modern machines and systems, binary sensors and actuators are connected
together via AS-Interface.
Until now it was necessary to go back to the use of costly conventional wiring when
wanting to use absolute encoders. The reason for this was that the handshake
mode with the control module of the analogue profile proved to be too slow for posi-
Inductive sensors

tioning tasks.
In order to meet the real-time demands of many applications, a multi-slave solution
using the BVS58
AS-Interface rotary encoders was created. The position value of 13 Bits in length is
transferred within a single cycle via the 4 integrated AS-Interface chips to the mas-
ter and made available to the PLC.
This singleturn absolute encoder is available either in clamping flange design with a
Photoelectric

shaft 10 mm in diameter x 20 mm or in servo flange design with a shaft 6 mm in


sensors

diameter x 10 mm.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
274 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BVS58
Technical data

Masters and
BVS58

Gateways
Electrical specifications
Operating voltage 29.5 ... 31.6 V DC
No-load supply current max. starting current 155 mA , operational current max. 65 mA
Linearity ± 1 LSB

Extender, Repeaters
Output code parameterisable, Gray code, binary code

Power Supplies,
Code course (counting direction) parameterisable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending)
Interface
Interface type AS-Interface
Transfer rate max. 0.167 MBit/s
Resolution

Safety at work
Singleturn 13 Bit
Standard conformity AS-Interface
Connection
Connector type V1, M12, 4-pin
Standard conformity

Control cabinet
Protection degree DIN EN 60529, IP65

I/O Modules
Climatic testing DIN EN 60068-2-3, no moisture condensation
Emitted interference DIN EN 50081-1
Interference rejection DIN EN 61000-6-2
Shock resistance DIN EN 60068-2-27, 100 g, 6 ms
Vibration resistance DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz

Field application
Ambient conditions

I/O Modules
Operating temperature -20 ... 70 °C (253 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Material
Combination 1 housing: aluminium, powder coated

Analogue modules
flange: aluminium 3.1645
shaft: stainless steel 1.4305
Combination 2 (Inox) housing: stainless steel 1.4305
flange: stainless steel 1.4305
shaft: stainless steel 1.4305
Mass approx. 330 g (combination 1)
approx. 750 g (combination 2)
Rotational speed max. 12000 min -1

Other modules
Moment of inertia 30 gcm2
Starting torque ≤ 1.5 Ncm
Shaft load
Axial 40 N at max. 6000 min-1
10 N at max. 12000 min-1
60 N at max. 6000 min-1

Inductive sensors
Radial
20 N at max. 12000 min-1

Electrical connection
Signal V1 connector, 4-pin Explanation
AS-Interface + 1
Photoelectric

Reserved 2 Not wired


sensors

AS-Interface - 3
Reserved 4 Not wired
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 4 3 2
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 275
Singleturn absolute encoder BVS58

Addresses
Masters and
Gateways

Slave A Slave B Slave C Slave D


Preset address 1 2 3 4
IO code 7 0 0 0
ID code F F F F
Extender, Repeaters

When readdressing by means of a bus master or a programming device, it is absolutely essential to assign different
Power Supplies,

addresses to the four integrated AS-Interface chips.

Parameter bits
The four parameter bits of slave A are used to set the parameters of the rotary encoder.
The parameter bits of slave B, C and D are not used.
Safety at work

Status of Slave A
parameter bit P0 P1 P2 P3
0 Gray code Transfer with flag bits Descending counting direction for clockwise rotation Not used
1 Binary code Transfer without flag bits Ascending counting direction for clockwise rotation Not used
Control cabinet

Data bits
I/O Modules

From the AS-Interface master to the rotary encoder


Data from the AS-Interface master are transferred to the rotary encoder via slave A, which works bidirectionally. Slaves B, C
and D work unidirectionally, i.e. they are incapable of receiving data.
Status of Slave A
Field application

D0/D1 or D2/D3 D0/D1 D2/D3


I/O Modules

00 Normal mode Position data are not saved!


01 Rotary encoder is set to ¼ of the singleturn resolution. Position data are saved!
10 Rotary encoder is set to 0. Position data are saved!
11 Normal mode Position data are not saved!
When a change is made in data bits D2 and D3 from 01 to 10 or vice-versa, position data are resaved in the rotary encoder.
Analogue modules

From the rotary encoder to the AS-Interface master


Depending on the value of parameter bit P1 of slave A, data transfer to the AS-Interface master takes place with or without flag
bits.
P1 = 1: Transfer without flag bits
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Other modules

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 10 Bit 11 Bit 12 Not used!
P1 = 0: Transfer with flag bits MA, MB, MC, MD
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Bit 0 Bit 1 Bit 2 MA Bit 3 Bit 4 Bit 5 MB Bit 6 Bit 7 Bit 8 MC Bit 9 Bit 10 Bit 11 MD
Inductive sensors

Operating modes

Address assignments for the four slaves


The AS-Interface master accesses all slaves one after the other within an AS-Interface cycle in order to transfer output data to
slave A or to read in input data from the slaves. The singleturn absolute encoder uses only four AS-Interface chips to transfer
the position data that are 13 bits wide, i. e. four slave addresses are assigned.
Photoelectric
sensors

Since these four slaves are queried one after the other, the data may originate from any one of four different sampling times. To
minimise the influence of this effect, sequential addresses (n, n+1, n+2 and n+3) should be assigned to slaves A, B, C and D.
Furthermore, it should be noted that slave A is responsible for controlling the functions of the absolute encoder. If the order of
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the slaves is changed (D = n, C = n+1, B = n+2, A = n+3), the output word, which is supposed to be transmitted by the function
control module of the absolute encoder, will not be transmitted until slaves D, C and B have been read in.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
276 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BVS58
A memory command would thus only take effect for slave A. The command would not take effect for slaves that were already
read until the next read cycle. Data consistency would be lost because of the change of order.

Masters and
Gateways
Temporary storage and transfer with flag bits
If individual telegrams of the four slaves to the AS-Interface master suffer interference, it may happen in spite of temporary stor-
age in the rotary encoder that the data that are transferred to the control module do not all originate from the same position data
set.

Extender, Repeaters
Transferring one flag bit for each slave makes it possible for the control module to check which position data set an individual

Power Supplies,
data set belongs to by comparing the four flag bits. Data bit D2 is used for this purpose.
Example:
Slave A Position data
Cycle Data bit D2 Slave A Slave B Slave C Slave D
1 0 XXX0 XXX0 XXX0 XXX0
2 1 XXX1 XXX1 XXX1 XXX1

Safety at work
3 0 XXX0 XXX0 XXX0 XXX0
4 1 XXX1 XXX1 XXX1 XXX1
etc.
Bit D2 is influenced by the control module. Bit 4 of the input data corresponds to the value of this bit for each slave.
D2 is set to 0 in cycle 1. If the value of bit 4 of a slave were "1", that value would be derived from another cycle. This is a simple
way to recognise data consistency.

Control cabinet
I/O Modules
Transferring the flag bits, however, reduces the usable position data from 13 bits to 12. Masking out the fourth bit of each slave
increases slightly the effort of putting together the position data set in the control module.

Accessories
For type Accessories Name/defining feature Order code

Field application
D1: Ø10 mm, D2: Ø10 mm 9401

I/O Modules
D1: Ø10 mm, D2: Ø10 mm 9404
Couplings
D1: Ø10 mm, D2: Ø10 mm 9409
D1: Ø10 mm, D2: Ø10 mm KW
Plastic 9101, 10

Analogue modules
Measurement wheels with cir- Pimpled rubber 9102, 10
cumference of 500 mm Knurled aluminium 9103, 10
BVS58*-011
Knurled plastic 9112, 10
Plastic 9108, 10
Measurement wheels with cir- Pimpled rubber 9109, 10
cumference of 200 mm Knurled aluminium 9110, 10
Knurled plastic 9113, 10

Other modules
Mounting bracket 9203
Mounting aids
Mounting bracket 9213
D1: Ø6 mm, D2: Ø6 mm 9401
D1: Ø6 mm, D2: Ø6 mm 9402
Couplings D1: Ø6 mm, D2: Ø6 mm 9404

Inductive sensors
BVS58*-032 D1: Ø6 mm, D2: Ø6 mm 9409
D1: Ø6 mm, D2: Ø6 mm KW
Mounting bracket and set 9300 and 9311-3
Mounting aids
Eccentric clamping elements 9310-3
All Connector Cable socket V1
For additional information on the accessories, please see the "Accessories" section.
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 277
Singleturn absolute encoder BVS58

Order code
Masters and
Gateways

B V S 5 8 – A V R 0 N N – 0 0 1 3
Extender, Repeaters

Number of bits singleturn


Power Supplies,

13 8192
Number of bits multiturn
00 None
Option 2
N Not expanded
Output code
Safety at work

N Selectable, binary/Gray
Option 1
0 No option
Exit position
R Radial
Connection type
Control cabinet

AV Plug connector type V1, 4-pin


I/O Modules

Shaft dimension/flange version


011 Shaft Ø10 mm x 20 mm with clamping flange
032 Shaft Ø6 mm x 10 mm with servo flange
Housing material
N Aluminium, powder coated
Field application

I Inox*
I/O Modules

Principle of operation
S Singleturn
Shaft version
V Solid shaft
Data format
Analogue modules

B AS-Interface *Housing material I only available with axial exit position.


Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
278 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BVS58

Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 279
BSS58

Singleturn absolute encoder BSS58

Dimensions
Masters and
Gateways

67
Straight pin 11
DIN 7- 4 x 20 ø58 ± 0.1
10 12 1.5
8 60
˚
Extender, Repeaters

ø12.01H7
Power Supplies,

ø4

R22
ø12h7
Set screw ø19.8
DIN 913

52.9
M3 SW1.5
Safety at work

2.5 7
Minimum insertion depth 20
21
(9.5) 41
Connector V1, radial Recessed hollow shaft
Control cabinet
I/O Modules

Function
In modern machines and systems, binary sensors and actuators are connected
Order code together via AS-Interface.
Series BSS58 Until now it was necessary to go back to the use of costly conventional wiring when
See type key code for correct order code wanting to use absolute encoders. The reason for this was that the handshake
Field application

mode with the control module of the analogue profile proved to be too slow for posi-
I/O Modules

tioning tasks.
In order to meet the real-time demands of many applications, a multi-slave solution
Features using the BSS58
AS-Interface rotary encoders was created. The position value of 13 Bits in length is
• Industrial standard housing Ø58 mm
transferred within a single cycle via the 4 integrated AS-Interface chips to the mas-
Analogue modules

• 13 Bit singleturn ter and made available to the PLC.


• Output code: Gray and binary The absolute encoder is mounted directly onto the application shaft, without any
coupling. Rotation of the absolute encoder is prevented by a torque rest. This may
• Transfer of position data with 4 AS-
simply be a slide-in pin that locks in the plastic receptacle integrated into the flange.
Interface slaves
• Parameterisation and addressing via
AS-Interface
Other modules

• Recessed hollow shaft


Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
280 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BSS58
Technical data

Masters and
BSS58

Gateways
Electrical specifications
Operating voltage 29.5 ... 31.6 V DC
No-load supply current max. starting current 155 mA , operational current max. 65 mA
Linearity ± 1 LSB

Extender, Repeaters
Output code parameterisable, Gray code, binary code

Power Supplies,
Code course (counting direction) parameterisable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending)
Interface
Interface type AS-Interface
Transfer rate max. 0.167 MBit/s
Resolution

Safety at work
Singleturn 13 Bit
Standard conformity AS-Interface
Connection
Connector type V1, M12, 4-pin
Standard conformity

Control cabinet
Protection degree DIN EN 60529, IP65

I/O Modules
Climatic testing DIN EN 60068-2-3, no moisture condensation
Emitted interference DIN EN 50081-1
Interference rejection DIN EN 61000-6-2
Shock resistance DIN EN 60068-2-27, 100 g, 6 ms
Vibration resistance DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz

Field application
Ambient conditions

I/O Modules
Operating temperature -20 ... 70 °C (253 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Material
Combination 1 housing: aluminium, powder coated

Analogue modules
flange: aluminium 3.1645
shaft: stainless steel 1.4305
Combination 2 (Inox) housing: stainless steel 1.4305
flange: stainless steel 1.4305
shaft: stainless steel 1.4305
Mass approx. 330 g (combination 1)
approx. 750 g (combination 2)
Rotational speed max. 10000 min -1

Other modules
Moment of inertia 30 gcm2
Starting torque ≤ 1.5 Ncm
Tightening torque, fixing screws max. 1.8 Nm
Shaft load
Angle offset 1°

Inductive sensors
Axial offset max. 1 mm

Electrical connection
Signal V1 connector, 4-pin Explanation
AS-Interface + 1
Reserved 2 Not wired
Photoelectric

AS-Interface - 3
sensors

Reserved 4 Not wired


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 4 3 2
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 281
Singleturn absolute encoder BSS58

Addresses
Masters and
Gateways

Slave A Slave B Slave C Slave D


Preset address 1 2 3 4
IO code 7 0 0 0
ID code F F F F
Extender, Repeaters

When readdressing by means of a bus master or a programming device, it is absolutely essential to assign different
Power Supplies,

addresses to the four integrated AS-Interface chips.

Parameter bits
The four parameter bits of slave A are used to set the parameters of the rotary encoder.
The parameter bits of slave B, C and D are not used.
Safety at work

Status of Slave A
parameter bit P0 P1 P2 P3
0 Gray code Transfer with flag bits Descending counting direction for clockwise rotation Not used
1 Binary code Transfer without flag bits Ascending counting direction for clockwise rotation Not used
Control cabinet

Data bits
I/O Modules

From the AS-Interface master to the rotary encoder


Data from the AS-Interface master are transferred to the rotary encoder via slave A, which works bidirectionally. Slaves B, C
and D work unidirectionally, i.e. they are incapable of receiving data.
Status of Slave A
Field application

D0/D1 or D2/D3 D0/D1 D2/D3


I/O Modules

00 Normal mode Position data are not saved!


01 Rotary encoder is set to ¼ of the singleturn resolution. Position data are saved!
10 Rotary encoder is set to 0. Position data are saved!
11 Normal mode Position data are not saved!
When a change is made in data bits D2 and D3 from 01 to 10 or vice-versa, position data are resaved in the rotary encoder.
Analogue modules

From the rotary encoder to the AS-Interface master


Depending on the value of parameter bit P1 of slave A, data transfer to the AS-Interface master takes place with or without flag
bits.
P1 = 1: Transfer without flag bits
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Other modules

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 10 Bit 11 Bit 12 Not used!
P1 = 0: Transfer with flag bits MA, MB, MC, MD
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Bit 0 Bit 1 Bit 2 MA Bit 3 Bit 4 Bit 5 MB Bit 6 Bit 7 Bit 8 MC Bit 9 Bit 10 Bit 11 MD
Inductive sensors

Operating modes

Address assignments for the four slaves


The AS-Interface master accesses all slaves one after the other within an AS-Interface cycle in order to transfer output data to
slave A or to read in input data from the slaves. The singleturn absolute encoder uses only four AS-Interface chips to transfer
the position data that are 13 bits wide, i. e. four slave addresses are assigned.
Photoelectric
sensors

Since these four slaves are queried one after the other, the data may originate from any one of four different sampling times. To
minimise the influence of this effect, sequential addresses (n, n+1, n+2 and n+3) should be assigned to slaves A, B, C and D.
Furthermore, it should be noted that slave A is responsible for controlling the functions of the absolute encoder. If the order of
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the slaves is changed (D = n, C = n+1, B = n+2, A = n+3), the output word, which is supposed to be transmitted by the function
control module of the absolute encoder, will not be transmitted until slaves D, C and B have been read in.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
282 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BSS58
A memory command would thus only take effect for slave A. The command would not take effect for slaves that were already
read until the next read cycle. Data consistency would be lost because of the change of order.

Masters and
Gateways
Temporary storage and transfer with flag bits
If individual telegrams of the four slaves to the AS-Interface master suffer interference, it may happen in spite of temporary stor-
age in the rotary encoder that the data that are transferred to the control module do not all originate from the same position data
set.

Extender, Repeaters
Transferring one flag bit for each slave makes it possible for the control module to check which position data set an individual

Power Supplies,
data set belongs to by comparing the four flag bits. Data bit D2 is used for this purpose.
Example:
Slave A Position data
Cycle Data bit D2 Slave A Slave B Slave C Slave D
1 0 XXX0 XXX0 XXX0 XXX0
2 1 XXX1 XXX1 XXX1 XXX1

Safety at work
3 0 XXX0 XXX0 XXX0 XXX0
4 1 XXX1 XXX1 XXX1 XXX1
etc.
Bit D2 is influenced by the control module. Bit 4 of the input data corresponds to the value of this bit for each slave.
D2 is set to 0 in cycle 1. If the value of bit 4 of a slave were "1", that value would be derived from another cycle. This is a simple
way to recognise data consistency.

Control cabinet
I/O Modules
Transferring the flag bits, however, reduces the usable position data from 13 bits to 12. Masking out the fourth bit of each slave
increases slightly the effort of putting together the position data set in the control module.

Accessories
Accessories Name/defining feature Order code

Field application
Connector Cable socket V1

I/O Modules
For additional information on the accessories, please see the "Accessories" section.

Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 283
Singleturn absolute encoder BSS58

Order code
Masters and
Gateways

B S S 5 8 – A V R 0 N N – 0 0 1 3
Extender, Repeaters

Number of bits singleturn


Power Supplies,

13 8192
Option 2
N Not expanded
Output code
N Selectable, binary/Gray
Option 1
Safety at work

0 No option
Exit position
R Radial
Connection type
AV Plug connector type V1, 4-pin
Shaft dimension/flange version
Control cabinet

01A Recessed hollow shaft Ø10 mm x 21 mm


I/O Modules

02A Recessed hollow shaft Ø12 mm x 21 mm


Housing material
N Aluminium, powder coated
I Inox*
Principle of operation
Field application

S Singleturn
I/O Modules

Shaft version
S Recessed hollow shaft
Data format
B AS-Interface *Housing material I only available with axial exit position.
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
284 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BSS58

Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 285
BVE14

Singleturn absolute encoder BVE14

Dimensions
Masters and
Gateways

(175)
25 510 92 43
3
x
12
Extender, Repeaters


Power Supplies,

ø12

ø11.2
ø80
ø40

ø44
4
Safety at work

2.5 3 x M6
Clamping flange ø60
ø116
Control cabinet
I/O Modules

Function
0102
In modern machines and systems, binary sensors and actuators are connected
Order code together via AS-Interface.
Series BVE14 Until now it was necessary to go back to the use of costly conventional wiring when
See type key code for correct order code wanting to use absolute encoders. The reason for this was that the handshake
Field application

mode with the control module of the analogue profile proved to be too slow for posi-
I/O Modules

tioning tasks.
In order to meet the real-time demands of many applications, a multi-slave solution
Features using the BVE14
AS-Interface rotary encoders was created. The position value of 13 Bits in length is
• 13 Bit singleturn
transferred within a single cycle with the 4 integrated AS-Interface chips to the mas-
Analogue modules

• ATEX approval ter and made available to the PLC.


• Flameproof enclosure The shaft is specially equipped with a feather key groove for receiving a belt pulley
or similar device. The permissible radial force is 80 N, while the permissible axial
• Output code: Gray and binary
force is 60 N.
• Transfer of position data with 4 AS- One special feature is the mechanical versatility of the flange. The absolute
Interface slaves encoder has one centering shoulder with a diameter of 40 mm and one with a
• Parameterisation and addressing via diameter of 80 mm. Three M6 holes are available for fastening.
Other modules

AS-Interface
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
286 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BVE14
Technical data

Masters and
BVE14

Gateways
Electrical specifications
Operating voltage 29.5 ... 31.6 V DC
No-load supply current max. starting current 155 mA , operational current max. 65 mA
Linearity ± 2 LSB

Extender, Repeaters
Output code parameterisable, Gray code, binary code

Power Supplies,
Code course (counting direction) parameterisable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending)
Interface
Interface type AS-Interface
Transfer rate max. 0.167 MBit/s
Resolution

Safety at work
Singleturn 13 Bit
Standard conformity AS-Interface
Connection
Cable Ø11.2 mm, 9-core, 2 m
Standard conformity

Control cabinet
Protection degree DIN EN 60529, IP66

I/O Modules
Climatic testing DIN EN 60068-2-3, no moisture condensation
Emitted interference DIN EN 50081-1
Interference rejection DIN EN 61000-6-2
Shock resistance DIN EN 60068-2-27, 100 g, 3 ms
Vibration resistance DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz

Field application
Ambient conditions

I/O Modules
Operating temperature -20 ... 55 °C (253 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Material
Housing aluminium 3.1645

Analogue modules
Flange aluminium 3.1645
Shaft stainless steel 1.4305
Mass approx. 3240 g
Rotational speed max. 6000 min -1
Moment of inertia 400 gcm2
Starting torque ≤ 1.5 Ncm
Shaft load

Other modules
Axial 40 N
Radial 60 N
Data for application in conjunction
with hazardous areas
EC-Type Examination Certificate ZELM 02 ATEX 0078
Group, category, type of protection ¬ II 2 G EEx d IIC T6

Inductive sensors
¬ II 2 D IP66 T80°C
Directive conformity
Directive 94/9 EC EN 50014, EN 50018

Electrical connection
Signal Cable Ø11.2 mm, 9-core
Photoelectric

Protective conductor Green/Yellow


sensors

AS-Interface (+) 1
AS-Interface (-) 2
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Reserved 3
Reserved 4
Reserved 5
Rotary encoders

Reserved 6
Reserved 7
Reserved 8
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 287
Singleturn absolute encoder BVE14

Addresses
Masters and
Gateways

Slave A Slave B Slave C Slave D


Preset address 1 2 3 4
IO code 7 0 0 0
ID code F F F F
Extender, Repeaters

When readdressing by means of a bus master or a programming device, it is absolutely essential to assign different
Power Supplies,

addresses to the four integrated AS-Interface chips.

Parameter bits
The four parameter bits of slave A are used to set the parameters of the rotary encoder.
The parameter bits of slave B, C and D are not used.
Safety at work

Status of Slave A
parameter bit P0 P1 P2 P3
0 Gray code Transfer with flag bits Descending counting direction for clockwise rotation Not used
1 Binary code Transfer without flag bits Ascending counting direction for clockwise rotation Not used
Control cabinet

Data bits
I/O Modules

From the AS-Interface master to the rotary encoder


Data from the AS-Interface master are transferred to the rotary encoder via slave A, which works bidirectionally. Slaves B, C
and D work unidirectionally, i.e. they are incapable of receiving data.
Status of Slave A
Field application

D0/D1 or D2/D3 D0/D1 D2/D3


I/O Modules

00 Normal mode Position data are not saved!


01 Rotary encoder is set to ¼ of the singleturn resolution. Position data are saved!
10 Rotary encoder is set to 0. Position data are saved!
11 Normal mode Position data are not saved!
When a change is made in data bits D2 and D3 from 01 to 10 or vice-versa, position data are resaved in the rotary encoder.
Analogue modules

From the rotary encoder to the AS-Interface master


Depending on the value of parameter bit P1 of slave A, data transfer to the AS-Interface master takes place with or without flag
bits.
P1 = 1: Transfer without flag bits
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Other modules

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 10 Bit 11 Bit 12 Not used!
P1 = 0: Transfer with flag bits MA, MB, MC, MD
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Bit 0 Bit 1 Bit 2 MA Bit 3 Bit 4 Bit 5 MB Bit 6 Bit 7 Bit 8 MC Bit 9 Bit 10 Bit 11 MD
Inductive sensors

Operating modes

Address assignments for the four slaves


The AS-Interface master accesses all slaves one after the other within an AS-Interface cycle in order to transfer output data to
slave A or to read in input data from the slaves. The singleturn absolute encoder uses only four AS-Interface chips to transfer
the position data that are 13 bits wide, i. e. four slave addresses are assigned.
Photoelectric
sensors

Since these four slaves are queried one after the other, the data may originate from any one of four different sampling times. To
minimise the influence of this effect, sequential addresses (n, n+1, n+2 and n+3) should be assigned to slaves A, B, C and D.
Furthermore, it should be noted that slave A is responsible for controlling the functions of the absolute encoder. If the order of
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the slaves is changed (D = n, C = n+1, B = n+2, A = n+3), the output word, which is supposed to be transmitted by the function
control module of the absolute encoder, will not be transmitted until slaves D, C and B have been read in.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
288 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Singleturn absolute encoder BVE14
A memory command would thus only take effect for slave A. The command would not take effect for slaves that were already
read until the next read cycle. Data consistency would be lost because of the change of order.

Masters and
Gateways
Temporary storage and transfer with flag bits
If individual telegrams of the four slaves to the AS-Interface master suffer interference, it may happen in spite of temporary stor-
age in the rotary encoder that the data that are transferred to the control module do not all originate from the same position data
set.

Extender, Repeaters
Transferring one flag bit for each slave makes it possible for the control module to check which position data set an individual

Power Supplies,
data set belongs to by comparing the four flag bits. Data bit D2 is used for this purpose.
Example:
Slave A Position data
Cycle Data bit D2 Slave A Slave B Slave C Slave D
1 0 XXX0 XXX0 XXX0 XXX0
2 1 XXX1 XXX1 XXX1 XXX1

Safety at work
3 0 XXX0 XXX0 XXX0 XXX0
4 1 XXX1 XXX1 XXX1 XXX1
etc.
Bit D2 is influenced by the control module. Bit 4 of the input data corresponds to the value of this bit for each slave.
D2 is set to 0 in cycle 1. If the value of bit 4 of a slave were "1", that value would be derived from another cycle. This is a simple
way to recognise data consistency.

Control cabinet
I/O Modules
Transferring the flag bits, however, reduces the usable position data from 13 bits to 12. Masking out the fourth bit of each slave
increases slightly the effort of putting together the position data set in the control module.

Order code

Field application
B V E 1 4 – 1 2 3 B – 8 1 9 2

I/O Modules
Steps per revolution

Analogue modules
Connection type
3 Cable Ø11.2 mm, 8-core and protective conductor, 2 m
Principle of operation
E Singleturn
Shaft version
V Solid shaft
Data format

Other modules
B AS-Interface

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 289
BVM58

Multiturn absolute encoder BVM58

Dimensions
Masters and
Gateways

(107)
77 ø48 ± 0.1
0.05 A 20 10 3 3


12
0.5 + 0.1
Extender, Repeaters

3x
Power Supplies,

15
A

ø10h7
ø36f8
ø52
ø58
17.5
Safety at work

52.9
3 x M3
0.2 A
7 deep

Clamping flange
Connector V1, radial
Control cabinet

(97)
I/O Modules

83 ø42 ± 0.1
10 4 3 3
0.05 A
Order code


12
Series BVM58
0.5 + 0.1

3x
See type key code for correct order code A
Field application

ø50h7
I/O Modules

ø58

ø6h7

17.5
Features

52.9
• Industrial standard housing Ø58 mm 3 x M4
0.2 A
Analogue modules

10 deep
• 16 Bit multiturn
Servo flange
• Output code: Gray and binary
• Transfer of position data with 4 AS- Connector V1, radial

Interface slaves
• Parameterisation and addressing via
AS-Interface Function
Other modules

• Servo or clamping flange In modern machines and systems, binary sensors and actuators are connected
together via AS-Interface.
Until now it was necessary to go back to the use of costly conventional wiring when
wanting to use absolute encoders. The reason for this was that the handshake
mode with the control module of the analogue profile proved to be too slow for posi-
Inductive sensors

tioning tasks.
In order to meet the real-time demands of many applications, a multi-slave solution
using the BVM58 AS-Interface rotary encoders was created. The position value of
16 Bits in length is transferred within a single cycle via the 4 integrated AS-Interface
chips to the master and made available to the PLC.
This multiturn absolute encoder is available either in clamping flange design with a
shaft 10 mm in diameter x 20 mm or in servo flange design with a shaft 6 mm in
Photoelectric

diameter x 10 mm.
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
290 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BVM58
Technical data

Masters and
BVM58

Gateways
Electrical specifications
Operating voltage 29.5 ... 31.6 V DC
No-load supply current max. starting current 155 mA , operational current max. 65 mA
Linearity ± 1 LSB

Extender, Repeaters
Output code parameterisable, Gray code, binary code

Power Supplies,
Code course (counting direction) parameterisable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending)
Interface
Interface type AS-Interface
Transfer rate max. 0.167 MBit/s
Resolution

Safety at work
Singleturn max. 13 Bit
Multiturn max. 12 Bit
Overall resolution 16 Bit
Standard conformity AS-Interface
Connection
Connector type V1, M12, 4-pin

Control cabinet
I/O Modules
Standard conformity
Protection degree DIN EN 60529, IP65
Climatic testing DIN EN 60068-2-3, no moisture condensation
Emitted interference DIN EN 50081-1
Interference rejection DIN EN 61000-6-2
Shock resistance DIN EN 60068-2-27, 100 g, 3 ms

Field application
I/O Modules
Vibration resistance DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz
Ambient conditions
Operating temperature -20 ... 70 °C (253 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications

Analogue modules
Material
Combination 1 housing: aluminium, powder coated
flange: aluminium 3.1645
shaft: stainless steel 1.4305
Combination 2 (Inox) housing: stainless steel 1.4305
flange: stainless steel 1.4305
shaft: stainless steel 1.4305

Other modules
Mass approx. 360 g (combination 1)
approx. 800 g (combination 2)
Rotational speed max. 6000 min -1
Moment of inertia 30 gcm2
Starting torque ≤ 1.5 Ncm
Shaft load

Inductive sensors
Axial 40 N
Radial 60 N

Electrical connection
Signal V1 connector, 4-pin Explanation
AS-Interface + 1
Photoelectric

Reserved 2 Not wired


sensors

AS-Interface - 3
Reserved 4 Not wired
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

1 4 3 2
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 291
Multiturn absolute encoder BVM58

Addresses
Masters and
Gateways

Slave A Slave B Slave C Slave D


Preset address 1 2 3 4
IO code 7 0 0 0
ID code F F F F
Extender, Repeaters

When readdressing by means of a bus master or a programming device, it is absolutely essential to assign different
Power Supplies,

addresses to the four integrated AS-Interface chips.

Parameter bits
The four parameter bits of slave A are used to set the parameters of the rotary encoder.
The parameter bits of slave B, C and D are not used.
Safety at work

Status of Slave A
parameter bit P0 P1 P2 P3
0 Gray code Transfer with flag bits Descending counting direction for clockwise rotation Not used
1 Binary code Transfer without flag bits Ascending counting direction for clockwise rotation Not used
Control cabinet

Data bits
I/O Modules

From the AS-Interface master to the rotary encoder


Data from the AS-Interface master are transferred to the rotary encoder via slave A, which works bidirectionally. Slaves B, C
and D work unidirectionally, i.e. they are incapable of receiving data.
Status of Slave A
Field application

D0/D1 or D2/D3 D0/D1 D2/D3


I/O Modules

00 Normal mode Position data are not saved!


01 Rotary encoder is set to ¼ of the singleturn resolution. Position data are saved!
10 Rotary encoder is set to 0. Position data are saved!
11 Normal mode Position data are not saved!
When a change is made in data bits D2 and D3 from 01 to 10 or vice-versa, position data are resaved in the rotary encoder.
Analogue modules

From the rotary encoder to the AS-Interface master


Depending on the value of parameter bit P1 of slave A, data transfer to the AS-Interface master takes place with or without flag
bits.
P1 = 1: Transfer without flag bits
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Other modules

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 10 Bit 11 Bit 12 Bit 13 Bit 14 Bit 15
P1 = 0: Transfer with flag bits MA, MB, MC, MD
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Bit 0 Bit 1 Bit 2 MA Bit 3 Bit 4 Bit 5 MB Bit 6 Bit 7 Bit 8 MC Bit 9 Bit 10 Bit 11 MD
Inductive sensors

Operating modes

Address assignments for the four slaves


The AS-Interface master accesses all slaves one after the other within an AS-Interface cycle in order to transfer output data to
slave A or to read in input data from the slaves. The multiturn absolute encoder uses only four AS-Interface chips to transfer the
position data that are 16 bits wide, i. e. four slave addresses are assigned.
Photoelectric
sensors

Since these four slaves are queried one after the other, the data may originate from any one of four different sampling times. To
minimise the influence of this effect, sequential addresses (n, n+1, n+2 and n+3) should be assigned to slaves A, B, C and D.
Furthermore, it should be noted that slave A is responsible for controlling the functions of the absolute encoder. If the order of
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the slaves is changed (D = n, C = n+1, B = n+2, A = n+3), the output word, which is supposed to be transmitted by the function
control module of the absolute encoder, will not be transmitted until slaves D, C and B have been read in.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
292 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BVM58
A memory command would thus only take effect for slave A. The command would not take effect for slaves that were already
read until the next read cycle. Data consistency would be lost because of the change of order.

Masters and
Gateways
Temporary storage and transfer with flag bits
If individual telegrams of the four slaves to the AS-Interface master suffer interference, it may happen in spite of temporary stor-
age in the rotary encoder that the data that are transferred to the control module do not all originate from the same position data
set.

Extender, Repeaters
Transferring one flag bit for each slave makes it possible for the control module to check which position data set an individual

Power Supplies,
data set belongs to by comparing the four flag bits. Data bit D2 is used for this purpose.
Example:
Slave A Position data
Cycle Data bit D2 Slave A Slave B Slave C Slave D
1 0 XXX0 XXX0 XXX0 XXX0
2 1 XXX1 XXX1 XXX1 XXX1

Safety at work
3 0 XXX0 XXX0 XXX0 XXX0
4 1 XXX1 XXX1 XXX1 XXX1
etc.
Bit D2 is influenced by the control module. Bit 4 of the input data corresponds to the value of this bit for each slave.
D2 is set to 0 in cycle 1. If the value of bit 4 of a slave were "1", that value would be derived from another cycle. This is a simple
way to recognise data consistency.

Control cabinet
I/O Modules
Transferring the flag bits, however, reduces the usable position data from 13 bits to 12. Masking out the fourth bit of each slave
increases slightly the effort of putting together the position data set in the control module.

Resolution of the rotary encoder


Without flag bits With flag bits

Field application
Number of Steps per Number of Steps per

I/O Modules
Bits Bits Bits Bits
rotations revolution rotations revolution
8 03 8192 13 not allowed
Possible 16 04 4096 12 2 01 2048 11
combinations of 32 05 2048 11 4 02 1024 10
steps per 64 06 1024 10 8 03 512 09

Analogue modules
revolution and 128 07 512 09 16 04 256 08
number of rotations 256 08 256 08 32 05 128 07
512 09 128 07 64 06 64 06
1024 10 64 06 128 07 32 05
2048 11 32 05 256 08 16 04
4096 12 16 04 512 09 8 03

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 293
Multiturn absolute encoder BVM58

Accessories
Masters and
Gateways

For type Accessories Name/defining feature Order code


D1: Ø10 mm, D2: Ø10 mm 9401
D1: Ø10 mm, D2: Ø10 mm 9404
Couplings
D1: Ø10 mm, D2: Ø10 mm 9409
Extender, Repeaters

D1: Ø10 mm, D2: Ø10 mm KW


Power Supplies,

Plastic 9101, 10
Measurement wheels with cir- Pimpled rubber 9102, 10
cumference of 500 mm Knurled aluminium 9103, 10
BVM58*-011
Knurled plastic 9112, 10
Plastic 9108, 10
Measurement wheels with cir- Pimpled rubber 9109, 10
Safety at work

cumference of 200 mm Knurled aluminium 9110, 10


Knurled plastic 9113, 10
Mounting bracket 9203
Mounting aids
Mounting bracket 9213
D1: Ø6 mm, D2: Ø6 mm 9401
Control cabinet

D1: Ø6 mm, D2: Ø6 mm 9402


I/O Modules

Couplings D1: Ø6 mm, D2: Ø6 mm 9404


BVM58*-032 D1: Ø6 mm, D2: Ø6 mm 9409
D1: Ø6 mm, D2: Ø6 mm KW
Mounting bracket and set 9300 and 9311-3
Mounting aids
Eccentric clamping elements 9310-3
Field application

All Connector Cable socket V1


I/O Modules

For additional information on the accessories, please see the "Accessories" section.

Order code
Analogue modules

B V M 5 8 – A V R 0 N N –

Bit combinations
multiturn/singleturn (see table)
Option 2
Other modules

N Not expanded
Output code
N Selectable, binary/Gray
Option 1
0 No option
Exit position
Inductive sensors

R Radial
Connection type
AV Plug connector type V1, 4-pin
Shaft dimension/flange version
011 Shaft Ø10 mm x 20 mm with clamping flange
032 Shaft Ø6 mm x 10 mm with servo flange
Housing material
Photoelectric
sensors

N Aluminium, powder coated


I Inox*
Principle of operation
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

M Multiturn
Shaft version
Rotary encoders

V Solid shaft
Data format
B AS-Interface *Housing material I only available with axial exit position.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
294 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BVM58

Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 295
BSM58

Multiturn absolute encoder BSM58

Dimensions
Masters and
Gateways

94
Straight pin 11
DIN 7- 4 x 20 ø58 ± 0.1
10 12 1.5
8 60
˚
Extender, Repeaters
Power Supplies,

ø12.01H7

ø4

R22
ø12h7
Set screw ø19.8
DIN 913

52.9
M3 SW1.5
Safety at work

2.5 7
Minimum insertion depth 20
21
(9.5) 68
Connector V1, radial Recessed hollow shaft
Control cabinet
I/O Modules

Function
In modern machines and systems, binary sensors and actuators are connected
Order code together via AS-Interface.
Series BSM58 Until now it was necessary to go back to the use of costly conventional wiring when
See type key code for correct order code wanting to use absolute encoders. The reason for this was that the handshake
Field application

mode with the control module of the analogue profile proved to be too slow for posi-
I/O Modules

tioning tasks.
In order to meet the real-time demands of many applications, a multi-slave solution
Features using the BSM58 AS-Interface rotary encoders was created. The position value of
16 Bits in length is transferred within a single cycle via the 4 integrated AS-Interface
• Industrial standard housing Ø58 mm
chips to the master and made available to the PLC.
Analogue modules

• 16 Bit multiturn The absolute encoder is mounted directly onto the application shaft, without any
• Output code: Gray and binary coupling. Rotation of the absolute encoder is prevented by a torque rest. This may
simply be a slide-in pin that locks in the plastic receptacle integrated into the flange.
• Transfer of position data with 4 AS-
Interface slaves
• Parameterisation and addressing via
AS-Interface
Other modules

• Recessed hollow shaft


Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
296 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BSM58
Technical data

Masters and
BSM58

Gateways
Electrical specifications
Operating voltage 29.5 ... 31.6 V DC
No-load supply current max. starting current 155 mA , operational current max. 65 mA
Linearity ± 1 LSB

Extender, Repeaters
Output code parameterisable, Gray code, binary code

Power Supplies,
Code course (counting direction) parameterisable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending)
Interface
Interface type AS-Interface
Transfer rate max. 0.167 MBit/s
Resolution

Safety at work
Singleturn max. 13 Bit
Multiturn max. 12 Bit
Overall resolution 16 Bit
Standard conformity AS-Interface
Connection
Connector type V1, M12, 4-pin

Control cabinet
I/O Modules
Standard conformity
Protection degree DIN EN 60529, IP65
Climatic testing DIN EN 60068-2-3, no moisture condensation
Emitted interference DIN EN 50081-1
Interference rejection DIN EN 61000-6-2
Shock resistance DIN EN 60068-2-27, 100 g, 3 ms

Field application
I/O Modules
Vibration resistance DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz
Ambient conditions
Operating temperature -20 ... 70 °C (253 ... 343 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications

Analogue modules
Material
Combination 1 housing: aluminium, powder coated
flange: aluminium 3.1645
shaft: stainless steel 1.4305
Combination 2 (Inox) housing: stainless steel 1.4305
flange: stainless steel 1.4305
shaft: stainless steel 1.4305

Other modules
Mass approx. 360 g (combination 1)
approx. 800 g (combination 2)
Rotational speed max. 6000 min -1
Moment of inertia 30 gcm2
Starting torque ≤ 1.5 Ncm
Tightening torque, fixing screws max. 1.8 Nm

Inductive sensors
Shaft load
Angle offset 1°
Axial offset max. 1 mm

Electrical connection
Signal V1 connector, 4-pin Explanation
AS-Interface + 1
Photoelectric
sensors

Reserved 2 Not wired


AS-Interface - 3
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Reserved 4 Not wired


Rotary encoders

1 4 3 2
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 297
Multiturn absolute encoder BSM58

Addresses
Masters and
Gateways

Slave A Slave B Slave C Slave D


Preset address 1 2 3 4
IO code 7 0 0 0
ID code F F F F
Extender, Repeaters

When readdressing by means of a bus master or a programming device, it is absolutely essential to assign different
Power Supplies,

addresses to the four integrated AS-Interface chips.

Parameter bits
The four parameter bits of slave A are used to set the parameters of the rotary encoder.
The parameter bits of slave B, C and D are not used.
Safety at work

Status of Slave A
parameter bit P0 P1 P2 P3
0 Gray code Transfer with flag bits Descending counting direction for clockwise rotation Not used
1 Binary code Transfer without flag bits Ascending counting direction for clockwise rotation Not used
Control cabinet

Data bits
I/O Modules

From the AS-Interface master to the rotary encoder


Data from the AS-Interface master are transferred to the rotary encoder via slave A, which works bidirectionally. Slaves B, C
and D work unidirectionally, i.e. they are incapable of receiving data.
Status of Slave A
Field application

D0/D1 or D2/D3 D0/D1 D2/D3


I/O Modules

00 Normal mode Position data are not saved!


01 Rotary encoder is set to ¼ of the singleturn resolution. Position data are saved!
10 Rotary encoder is set to 0. Position data are saved!
11 Normal mode Position data are not saved!
When a change is made in data bits D2 and D3 from 01 to 10 or vice-versa, position data are resaved in the rotary encoder.
Analogue modules

From the rotary encoder to the AS-Interface master


Depending on the value of parameter bit P1 of slave A, data transfer to the AS-Interface master takes place with or without flag
bits.
P1 = 1: Transfer without flag bits
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Other modules

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 10 Bit 11 Bit 12 Bit 13 Bit 14 Bit 15
P1 = 0: Transfer with flag bits MA, MB, MC, MD
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Bit 0 Bit 1 Bit 2 MA Bit 3 Bit 4 Bit 5 MB Bit 6 Bit 7 Bit 8 MC Bit 9 Bit 10 Bit 11 MD
Inductive sensors

Operating modes

Address assignments for the four slaves


The AS-Interface master accesses all slaves one after the other within an AS-Interface cycle in order to transfer output data to
slave A or to read in input data from the slaves. The multiturn absolute encoder uses only four AS-Interface chips to transfer the
position data that are 16 bits wide, i. e. four slave addresses are assigned.
Photoelectric
sensors

Since these four slaves are queried one after the other, the data may originate from any one of four different sampling times. To
minimise the influence of this effect, sequential addresses (n, n+1, n+2 and n+3) should be assigned to slaves A, B, C and D.
Furthermore, it should be noted that slave A is responsible for controlling the functions of the absolute encoder. If the order of
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the slaves is changed (D = n, C = n+1, B = n+2, A = n+3), the output word, which is supposed to be transmitted by the function
control module of the absolute encoder, will not be transmitted until slaves D, C and B have been read in.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
298 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BSM58
A memory command would thus only take effect for slave A. The command would not take effect for slaves that were already
read until the next read cycle. Data consistency would be lost because of the change of order.

Masters and
Gateways
Temporary storage and transfer with flag bits
If individual telegrams of the four slaves to the AS-Interface master suffer interference, it may happen in spite of temporary stor-
age in the rotary encoder that the data that are transferred to the control module do not all originate from the same position data
set.

Extender, Repeaters
Transferring one flag bit for each slave makes it possible for the control module to check which position data set an individual

Power Supplies,
data set belongs to by comparing the four flag bits. Data bit D2 is used for this purpose.
Example:
Slave A Position data
Cycle Data bit D2 Slave A Slave B Slave C Slave D
1 0 XXX0 XXX0 XXX0 XXX0
2 1 XXX1 XXX1 XXX1 XXX1

Safety at work
3 0 XXX0 XXX0 XXX0 XXX0
4 1 XXX1 XXX1 XXX1 XXX1
etc.
Bit D2 is influenced by the control module. Bit 4 of the input data corresponds to the value of this bit for each slave.
D2 is set to 0 in cycle 1. If the value of bit 4 of a slave were "1", that value would be derived from another cycle. This is a simple
way to recognise data consistency.

Control cabinet
I/O Modules
Transferring the flag bits, however, reduces the usable position data from 13 bits to 12. Masking out the fourth bit of each slave
increases slightly the effort of putting together the position data set in the control module.

Resolution of the rotary encoder


Without flag bits With flag bits

Field application
Number of Steps per Number of Steps per

I/O Modules
Bits Bits Bits Bits
rotations revolution rotations revolution
8 03 8192 13 not allowed
Possible 16 04 4096 12 2 01 2048 11
combinations of 32 05 2048 11 4 02 1024 10
steps per 64 06 1024 10 8 03 512 09

Analogue modules
revolution and 128 07 512 09 16 04 256 08
number of rotations 256 08 256 08 32 05 128 07
512 09 128 07 64 06 64 06
1024 10 64 06 128 07 32 05
2048 11 32 05 256 08 16 04
4096 12 16 04 512 09 8 03

Other modules
Accessories
Accessories Name/defining feature Order code
Connector Cable socket V1
For additional information on the accessories, please see the "Accessories" section.

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 299
Multiturn absolute encoder BSM58

Order code
Masters and
Gateways

B S M 5 8 – A V R 0 N N –
Extender, Repeaters

Bit combinations
Power Supplies,

multiturn/singleturn (see table)


Option 2
N Not expanded
Output code
N Selectable, binary/Gray
Option 1
Safety at work

0 No option
Exit position
R Radial
Connection type
AV Plug connector type V1, 4-pin
Shaft dimension/flange version
Control cabinet

01A Recessed hollow shaft Ø10 mm x 21 mm


I/O Modules

02A Recessed hollow shaft Ø12 mm x 21 mm


Housing material
N Aluminium, powder coated
I Inox*
Principle of operation
Field application

M Multiturn
I/O Modules

Shaft version
S Recessed hollow shaft
Data format
B AS-Interface *Housing material I only available with axial exit position.
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
300 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BSM58

Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 301
BVM14

Multiturn absolute encoder BVM14

Dimensions
Masters and
Gateways

207
5
10
25 124 43
3
3 x M6 x1
Extender, Repeaters

0.5 A 20
Power Supplies,

ø116
A

ø80f7
ø40f7

ø44
4

ø11.2
ø12g6

R150
Safety at work

2.5
Clamping flange ø60
0.2 A
Control cabinet
I/O Modules

Function
0102
In modern machines and systems, binary sensors and actuators are connected
Order code together via AS-Interface.
Series BVM14 Until now it was necessary to go back to the use of costly conventional wiring when
See type key code for correct order code wanting to use absolute encoders. The reason for this was that the handshake
Field application

mode with the control module of the analogue profile proved to be too slow for posi-
I/O Modules

tioning tasks.
In order to meet the real-time demands of many applications, a multi-slave solution
Features using the BVM14 AS-Interface rotary encoders was created. The position value of
16 Bits in length is transferred within a single cycle via the 4 integrated AS-Interface
• 16 Bit multiturn
chips to the master and made available to the PLC.
Analogue modules

• ATEX approval The shaft is specially equipped with a feather key groove for receiving a belt pulley
• Flameproof enclosure or similar device. The permissible radial force is 80 N, while the permissible axial
force is 60 N.
• Output code: Gray and binary
One special feature is the mechanical versatility of the flange. The absolute
• Transfer of position data with 4 AS- encoder has one centering shoulder with a diameter of 40 mm and one with a
Interface slaves diameter of 80 mm. Three M6 holes are available for fastening.
• Parameterisation and addressing via
Other modules

AS-Interface
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
302 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BVM14
Technical data

Masters and
BVM14

Gateways
Electrical specifications
Operating voltage 29.5 ... 31.6 V DC
No-load supply current max. starting current 155 mA , operational current max. 65 mA
Linearity ± 2 LSB

Extender, Repeaters
Output code parameterisable, Gray code, binary code

Power Supplies,
Code course (counting direction) parameterisable,
cw ascending (clockwise rotation, code course ascending)
cw descending (clockwise rotation, code course descending)
Interface
Interface type AS-Interface
Transfer rate max. 0.167 MBit/s
Resolution

Safety at work
Singleturn 13 Bit
Multiturn 12 Bit
Overall resolution 16 Bit
Standard conformity AS-Interface
Connection
Cable Ø11.2 mm, 9-core, 2 m

Control cabinet
I/O Modules
Standard conformity
Protection degree DIN EN 60529, IP66
Climatic testing DIN EN 60068-2-3, no moisture condensation
Emitted interference DIN EN 50081-1
Interference rejection DIN EN 61000-6-2
Shock resistance DIN EN 60068-2-27, 100 g, 3 ms

Field application
I/O Modules
Vibration resistance DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz
Ambient conditions
Operating temperature -20 ... 55 °C (253 ... 328 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications

Analogue modules
Material
Housing aluminium 3.1645
Flange aluminium 3.1645
Shaft stainless steel 1.4305
Mass approx. 3400 g
Rotational speed max. 6000 min -1
Moment of inertia 400 gcm2

Other modules
Starting torque ≤ 1.5 Ncm
Shaft load
Axial 40 N
Radial 60 N
Data for application in conjunction
with hazardous areas

Inductive sensors
EC-Type Examination Certificate ZELM 02 ATEX 0078
Group, category, type of protection ¬ II 2 G EEx d IIC T6
¬ II 2 D IP66 T80°C
Directive conformity
Directive 94/9 EC EN 50014, EN 50018

Electrical connection
Photoelectric
sensors

Signal Cable Ø11.2 mm, 9-core


Protective conductor Green/Yellow
AS-Interface (+) 1
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface (-) 2
Reserved 3
Rotary encoders

Reserved 4
Reserved 5
Reserved 6
Reserved 7
Reserved 8
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 303
Multiturn absolute encoder BVM14

Addresses
Masters and
Gateways

Slave A Slave B Slave C Slave D


Preset address 1 2 3 4
IO code 7 0 0 0
ID code F F F F
Extender, Repeaters

When readdressing by means of a bus master or a programming device, it is absolutely essential to assign different
Power Supplies,

addresses to the four integrated AS-Interface chips.

Parameter bits
The four parameter bits of slave A are used to set the parameters of the rotary encoder.
The parameter bits of slave B, C and D are not used.
Safety at work

Status of Slave A
parameter bit P0 P1 P2 P3
0 Gray code Transfer with flag bits Descending counting direction for clockwise rotation Not used
1 Binary code Transfer without flag bits Ascending counting direction for clockwise rotation Not used
Control cabinet

Data bits
I/O Modules

From the AS-Interface master to the rotary encoder


Data from the AS-Interface master are transferred to the rotary encoder via slave A, which works bidirectionally. Slaves B, C
and D work unidirectionally, i.e. they are incapable of receiving data.
Status of Slave A
Field application

D0/D1 or D2/D3 D0/D1 D2/D3


I/O Modules

00 Normal mode Position data are not saved!


01 Rotary encoder is set to ¼ of the singleturn resolution. Position data are saved!
10 Rotary encoder is set to 0. Position data are saved!
11 Normal mode Position data are not saved!
When a change is made in data bits D2 and D3 from 01 to 10 or vice-versa, position data are resaved in the rotary encoder.
Analogue modules

From the rotary encoder to the AS-Interface master


Depending on the value of parameter bit P1 of slave A, data transfer to the AS-Interface master takes place with or without flag
bits.
P1 = 1: Transfer without flag bits
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Other modules

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 10 Bit 11 Bit 12 Bit 13 Bit 14 Bit 15
P1 = 0: Transfer with flag bits MA, MB, MC, MD
Slave A Slave B Slave C Slave D
D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3 D0 D1 D2 D3
Bit 0 Bit 1 Bit 2 MA Bit 3 Bit 4 Bit 5 MB Bit 6 Bit 7 Bit 8 MC Bit 9 Bit 10 Bit 11 MD
Inductive sensors

Operating modes

Address assignments for the four slaves


The AS-Interface master accesses all slaves one after the other within an AS-Interface cycle in order to transfer output data to
slave A or to read in input data from the slaves. The multiturn absolute encoder uses only four AS-Interface chips to transfer the
position data that are 16 bits wide, i. e. four slave addresses are assigned.
Photoelectric
sensors

Since these four slaves are queried one after the other, the data may originate from any one of four different sampling times. To
minimise the influence of this effect, sequential addresses (n, n+1, n+2 and n+3) should be assigned to slaves A, B, C and D.
Furthermore, it should be noted that slave A is responsible for controlling the functions of the absolute encoder. If the order of
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the slaves is changed (D = n, C = n+1, B = n+2, A = n+3), the output word, which is supposed to be transmitted by the function
control module of the absolute encoder, will not be transmitted until slaves D, C and B have been read in.
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
304 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Multiturn absolute encoder BVM14
A memory command would thus only take effect for slave A. The command would not take effect for slaves that were already
read until the next read cycle. Data consistency would be lost because of the change of order.

Masters and
Gateways
Temporary storage and transfer with flag bits
If individual telegrams of the four slaves to the AS-Interface master suffer interference, it may happen in spite of temporary stor-
age in the rotary encoder that the data that are transferred to the control module do not all originate from the same position data
set.

Extender, Repeaters
Transferring one flag bit for each slave makes it possible for the control module to check which position data set an individual

Power Supplies,
data set belongs to by comparing the four flag bits. Data bit D2 is used for this purpose.
Example:
Slave A Position data
Cycle Data bit D2 Slave A Slave B Slave C Slave D
1 0 XXX0 XXX0 XXX0 XXX0
2 1 XXX1 XXX1 XXX1 XXX1

Safety at work
3 0 XXX0 XXX0 XXX0 XXX0
4 1 XXX1 XXX1 XXX1 XXX1
etc.
Bit D2 is influenced by the control module. Bit 4 of the input data corresponds to the value of this bit for each slave.
D2 is set to 0 in cycle 1. If the value of bit 4 of a slave were "1", that value would be derived from another cycle. This is a simple
way to recognise data consistency.

Control cabinet
I/O Modules
Transferring the flag bits, however, reduces the usable position data from 13 bits to 12. Masking out the fourth bit of each slave
increases slightly the effort of putting together the position data set in the control module.

Resolution of the rotary encoder


Without flag bits With flag bits

Field application
Number of Steps per Number of Steps per

I/O Modules
Bits Bits Bits Bits
rotations revolution rotations revolution
8 03 8192 13 not allowed
Possible 16 04 4096 12 2 01 2048 11
combinations of 32 05 2048 11 4 02 1024 10
steps per 64 06 1024 10 8 03 512 09

Analogue modules
revolution and 128 07 512 09 16 04 256 08
number of rotations 256 08 256 08 32 05 128 07
512 09 128 07 64 06 64 06
1024 10 64 06 128 07 32 05
2048 11 32 05 256 08 16 04
4096 12 16 04 512 09 8 03

Other modules
Order code

B V M 1 4 – 1 2 3 B – –

Inductive sensors
Number of revolutions
(Combinations see table)
Steps per revolution
(Combinations see table)
Connection type
3 Cable Ø11.2 mm, 8-core and protective conductor, 2 m
Photoelectric

Principle of operation
sensors

M Multiturn
Shaft version
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

V Solid shaft
Data format
B AS-Interface
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 305
AS-Interface - Accessories
Masters and
Gateways
Extender, Repeaters
Power Supplies,
Safety at work
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules
Other modules
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
306 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Accessories

9 Accessories

Masters and
Gateways
This chapter includes all accessories which are necessary for the problem-
free installation and commissioning of an AS-Interface system.

Extender, Repeaters
AS-Interface hand-held programming unit

Power Supplies,
The AS-Interface System is very simple to commission. Address configura-
tion and first commissioning tests are performed using the VBP-HH1 AS-In-
terface hand-held. The slaves can be directly connected over the plug inter-
face, over a programming cable, or over an M12 connector cable. The one-
handed operation of the hand-held makes the address configuration of in-

Safety at work
dividual modules or of an entire network particularly easy. AS-Interface out-
puts can also be directly controlled from the hand-held for testing purposes.
The power supply of the hand-held is from batteries or using the included
power pack.

Control cabinet
AS-Interface flat cable

I/O Modules
In most AS-Interface installations, profiled flat cable is used. Flat cable
comes with a rubber sheathing and in an oil-resistant TPE version, in yellow
or black. If you are implementing intrinsically safe applications over AS-In-
terface, you can also select our flat cable labeled in red with "+++SAFE-

Field application
I/O Modules
TY+++".

Converters
Converters serve to connect different AS-Interface gateways to the RS 232

Analogue modules
interface of a PC. This allows the gateways to be configured using the AS-
i Control Tools software.

Bases
Bases for AS-Interface modules enable the simplified laying of AS-Interface

Other modules
flat cable Mechanical coding prevents incorrect installation Pepperl+Fuchs
offers various bases with and without addressing jacks, for flat and round
cable, and for different housing sizes.

Adapters and splitter boxes

Inductive sensors
Adapters and splitter boxes are available for any application: Screw-on
adapters in housings, cable exits for round cable, adapters to M12 connec-
tors, freely adjustable solutions, cable exits from yellow/black cable to 4-pin
M12 connector, splitter boxes for a second flat cable spur line, or mounting
clips for installation of flat cable.
Photoelectric
sensors

Power Rail
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

The Power Rail is an insert component into DIN standard rail. Devices in the
KF series can be snapped onto the rail to connect them to the AS-Interface
Rotary encoders

network.

Plugs and cable sockets


Pepperl+Fuchs, as your system supplier for AS-Interface, offers all compo-
nents necessary in practice.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 307
VBP-HH1

AS-Interface handheld VBP-HH1


Dimensions
Masters and
Gateways

80 34
42.5 30
Extender, Repeaters
Power Supplies,

54
5
Safety at work

214
155
Control cabinet
I/O Modules
Field application
I/O Modules

Order code
VBP-HH1
Indicating/operating means
Hand-held programming device
Display
Analogue modules

„↑“ button ==> Increments slave address


Features
„MODE“ button ==>
• Determining the slave address Einstellen des Betriebsmodus

• Readdressing with checking „↓“ button ==> Dencrements slave address


Other modules

• The slave connection is short-circuit


„PRG“ button ==>
and overload proof Programs new slave address
• Addressing or programming up to a „ADR“ button ==>
maximum of 62 slaves (A/B slaves) Reads slave address/switches on device

• Operation on the bus possible


ATTENTION!
Inductive sensors

• MODE key for switching between the Charge accumulator prior to initial commissioning.
different operating modes
• Optional optical interface
• Battery charger included with delivery
Technical data
General specifications
Photoelectric

Operating mode plug-in charging unit, 230 V AC, included in the delivery pack-
sensors

age
Indicators/operating means
Display LC display
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Keyboard membrane keys, 5 keys


Electrical specifications
8 h or ≥ 250 read/write procedures for fully charged battery
Rotary encoders

Operating duration
Power supply battery mode, please use only battery charger included with
delivery to charge (charging time about 14 h)
Interface
Interface type AS-Interface, short-circuit proof and overload-proof, or optical
Ambient conditions
Ambient temperature 0 ... 40 °C (273 ... 313 K)
Storage temperature -20 ... 40 °C (253 ... 313 K)
Accessories

Mechanical specifications
Protection degree IP20 according to EN 60529
Mass approx. 275 g

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
308 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface handheld VBP-HH1
Operating Documentation

Masters and
VBP-HH1-MAN-D

Gateways
Press "ADR“-key to switch on the device. It switches off again independently, if not operated
within about one minute. Manual, german
• Pressing the "ADR“ key causes the current slave address to be displayed. VBP-HH1-MAN-E
• The two keys „↑“ and „↓“ can be used to select the programmable address from the Manual, english
address ring (i.e. 31B, 0 ... 31, 0 ... 31A, 0 ... 31B, 0,1).

Extender, Repeaters
Power Supplies,
• A short key stroke causes the pages to turn stepwise, whereas holding down the key Accessories
causes the pages to scroll continuously (0.5 s per address).
VAZ-PK-1,5M-V1-G
• Pressing the "PRG“-key causes the new address to be loaded in the slave.
Connection cable module/hand-held pro-
• The correctly programmed address is automatically displayed after about 0.5 s. gramming device
• When „ADR“ and „PRG“ are held down simultaneously, the address of zero is programmed
in the slave

Safety at work
• Other key combinations do not trigger any actions.

Notes
The VBP-HH1 is a compact tool for address configuration of AS-Interface slaves (sensors, ac-
tuators and coupling modules).

Control cabinet
The mechanical connection is accomplished by means of a universal adaptor connector. The

I/O Modules
following devices or types can be plugged-on without any difficulties:
- V1 plug connection (M12)
- VariKont-M system
- VariKont system
- FP design

Field application
- AS-Interface coupling module

I/O Modules
(Series... -G1, G4.)
The VAZ-PK-1,5M-V1-G programming cable is used as interconnecting cable for devices of
the KF, KF2, G2, K2 and K3 series.

Display

Analogue modules
The LCD display indicates the address, the mode or an error code.

Error signals:
F1: AS-Interface overload
F2: Slave not found
F3: Programming error
F4: Destination address busy

Other modules
F5: Address of zero busy
F6: Found standard slave instead of extended slave
F7: Found extended slave instead of standard slave
F8: Reception error
LOBAT= Load accumulator battery!

Inductive sensors
After the first indication approx. 30 reading and addressing procedures are still pos-
sible. Load the accumulator battery using the battery charger .

Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 309
VAZ-FK-*-**

AS-Interface flat cable VAZ-FK-*-**


Dimensions
Masters and
Gateways

1.5 1.5
Extender, Repeaters

2
Power Supplies,

4
blue brown
Safety at work

3.6
6.5
10
Control cabinet

Technical data
I/O Modules

Electrical specifications
Nominal voltage Uo 300 V
Current loading capacity According to DIN VDE 0298 Part 4, Table 6, Column 4
Ambient conditions
Conductor temperature Operating mode: 90 °C (363 K)
Field application

Short-circuit: 200 °C (473 K)


I/O Modules

Ambient temperature -40 ... 85 °C (233 ... 358 K) inactive,


Order code -25 ... 85 °C (248 ... 358 K) active

VAZ-FK-*-** Mechanical specifications


Core cross-section Copper tin-plated, extra-fine wire, class 6 in accordance with
AS-Interface flat cable DIN VDE 0295
cross-section 1.5 mm2
Analogue modules

Bend radius min. permissible bend radii in accordance with DIN VDE 0298
Part 3, Table 2
Bending stress only permitted on the wide side of the cable
Tension loading max. 50 N/mm2 on laying acc. to DIN VDE 0298 Part 3
Features
Cable length 100 m
• Cable piercing technique Note The cable is intended for use as a bus power line in inside
areas. Only cable with a black sheathing is suitable for outside
• Resistant to environmental influence use.
Other modules

• Resistant to bending
Model number VAZ-FK-S-YE* VAZ-FK-S-BK VAZ-FK-R-YE VAZ-FK-R-BK
• Reverse polarity protected due to the
Version Standard Resistent to oil
shape of the cable AS Interface Ext. Auxiliary AS Interface ext. Auxiliary
• Halogen-free (PVC-free) power up to 24 V power up to 24 V
Technical data
• Does not give off silicone Materials Rubber mixture EM3 Thermoplastic Elastomer (TPE)
Inductive sensors

in keeping with German stand-


• Graduations in metres ard DIN VDE 0207 part 2
Leadisolation Rubber mixture in keeping with German standard
DIN VDE 0207 part 20
Cable colour yellow black yellow black
(similar to (similar to (similar to (similar to
RAL 1012) RAL 9005) RAL 1012) RAL 9005)
Photoelectric

* +++ SAFETY +++


is also available with SAFETY printed on in red
sensors

(order designation VAZ-FK-S-YE-SAFETY)


Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
310 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-PB-SIM

PROFIBUS master simulator VAZ-PB-SIM

Electrical connection

Masters and
Gateways
Sub-D connector Sub-D socket
RS 485 RS 232
3
3 RxD
RxD/TxD-P

Extender, Repeaters
Power Supplies,
2
TxD
TxD/TxD-N 8

5
µP GND

+5 V 6
4
DTR

Safety at work
5
GND 8
CTS

Order code
VAZ-PB-SIM

Control cabinet
PROFIBUS master simulator

I/O Modules
Technical data
Electrical specifications
Rated operational current Ie ≤ 60 mA
Power supply draws its 5 V power supply from the RS 485 interface of the
PROFIBUS slave
Features
Interface

Field application
• The PROFIBUS master simulator is a Protocol PROFIBUS DP V0

I/O Modules
simple universal tool for data Interface type standard PC RS-232 interface with 9-pin D-SUB connector
exchange with PROFIBUS slaves (female)
RS 485 interface with 9-pin Sub-D connector (male)
• Complete solution with hardware Transfer rate 19200 Bit/s
(UART) and software Cable length for RS 232 and RS 485 each max. 2 m
Ambient conditions

Analogue modules
Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -25 ... 70 °C (248 ... 343 K)
Mechanical specifications
Dimensions 63, 34, 17 mm (L, W, H)

Description

Other modules
The PROFIBUS master simulator is a simple universal machine tool
for data exchange with PROFIBUS slaves of almost all manufacturers
via PROFIBUS DP. The PROFIBUS master simulator can exchange
data with many PROFIBUS slaves even without GSD file, type file and
without PROFIBUS master. The PROFIBUS slaves with default I/O

Inductive sensors
width can be put into operation without additional input or additional
data files. Input data can be read and output data can be written. In
addition, the PROFIBUS DP master simulator allows the use of GSD
files as well as the input of special configurations to start data
exchange with PROFIBUS slaves. Address configuration of PROFI-
BUS slaves - especially IP 67 modules without address switch - is also
possible.
The follow-on PROFIBUS master simulator allows the user to search a
Photoelectric
sensors

complete PROFIBUS and to find all connected participants. In this


case however, the VAZ-PB-SIM must be plugged directly on a PROFI-
BUS slave. In addition the data, in particular the diagnostic function, is
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

meanwhile displayed not only in hexadecimal and binary format but


also in ASCII format. Output data can be transmitted consistently.
The PROFIBUS master simulator is supplied with the VAZ-PB-SIM,
Rotary encoders

which is an ideal interface converter between the RS 232 interface of the PC and the PROFIBUS. This UART has a highly compact design and
does not require an additional external voltage supply. Therefore, it is ideal for mobile use with a laptop or a notebook. The VAZ-PB-SIM is sim-
ply plugged on, between the PROFIBUS and the RS 232 connection cable.
In addition to the actual monitor and configuration program, DLL drivers for Windows as well as simple sample programs in C are now also
included in the delivery package enabling you to adapt your own applications to PROFIBUS-UART. However, the VAZ-PB-SIM is only a test
equipment or a start-up aid for PROFIBUS slaves and is therefore not suitable for controlling automation processes.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 311
VAZ-DN-SIM-USB

DeviceNet master simulator VAZ-DN-SIM-USB

Electrical connection
Masters and
Gateways

Sub-D connector USB connector


DeviceNet PC

4
Extender, Repeaters

0V
Power Supplies,

7
CAN-H 3
D+
µP

2
D-
2
CAN-L
Safety at work

1 +5 V
1 2 3 4 5

Order code 1 2 3 4
6 7 8 9
VAZ-DN-SIM-USB
Control cabinet

DeviceNet master simulator


I/O Modules

Technical data
Electrical specifications
Rated operational current Ie ≤ 60 mA
Power supply draws its 5 V power from USB of the PC
Features Interface
Interface type USB-PC-interface (USB-connector Serie A)
Field application

• The DeviceNet master simulator is a DeviceNet-interface with 9-pin sub-D connector (male)
I/O Modules

simple universal tool for data Transfer rate 125, 250 und 500 kBit/s
exchange with DeviceNet slaves Cable length max. 2 m
• Complete solution with hardware Ambient conditions
(UART) and software Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -25 ... 70 °C (248 ... 343 K)
Analogue modules

Description
Other modules

The DeviceNet master simulator is a simple universal tool for data


exchange with DeviceNet slaves of almost all manufacturers. Without
any additional inputs or additional files, the input data can be read and
the output data can be written, and diagnostic functions can be dis-
played.
Inductive sensors

In addition, the DeviceNet master simulator can of course read and


write attributes. Moreover, there is also the possibility to search a com-
plete DeviceNet branch for subscribers connected.
The addresses and the Baud rate of the DeviceNet slaves can also be
set. The E/A data are displayed hexadecimally as well as in binary
mode
In single bit mode, it is possible to keep the outputs set for as long as
the mouse key is pressed. The device identification is read out from
Photoelectric

the DeviceNet slave and is displayed with the I/O data.


sensors

The scope of delivery of the DeviceNet master simulator comprises the


DeviceNet dongle. The DeviceNet dongle is the ideal interface con-
verter between a USB port (the parallel interface of the PCs) and
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

DeviceNet. The dongle is very compact and is provided with energy by


the USB (from the keyboard interface of the PC). For this reason, it is
Rotary encoders

highly suitable for mobile use on a laptop computer or notebook.


The requirements are an 80486 processor PC or higher; all Microsoft Windows versions are supported. The scope of delivery comprises the
DeviceNet Master Simulator software.

Note:
A terminator (120 Ohm) has to be connected to the end of the DeviceNet line.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
312 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-R4-R2

Converter VAZ-R4-R2

Electrical connection

Masters and
Gateways
Sub-D connector Sub-D socket
RS 485 RS 232C
5
GND

Extender, Repeaters
4
DTR

Power Supplies,
3
A 3
TxD
µP
2
8 RxD
B

8
CTS

Safety at work
1 2 3 4 5 5 4 3 2 1
7
RTS

Order code
6 7 8 9 9 8 7 6
VAZ-R4-R2

Control cabinet
RS 232C/RS 485 converter

I/O Modules
Technical data
Electrical specifications
Power supply draws its power supply from RS 232 interface of the PC
Pin 4 (DTR) must be permanently high.
Features Interface
Interface type standard PC RS-232 interface with 9-pin D-SUB connector

Field application
• Direct connection to a PC (RS 232) (female)

I/O Modules
RS 485 interface with 9-pin Sub-D connector (male)
• Point to point connection only Transfer rate up to 57600 Bit/s
Cable length for RS 232 and RS 485 each max. 2 m
Ambient conditions
Ambient temperature 0 ... 55 °C (273 ... 328 K)
Storage temperature -25 ... 70 °C (248 ... 343 K)

Analogue modules
Mechanical specifications
Connection RS 232 , RS 485
Dimensions 63, 54, 17 mm (L, W, H)

Description

Other modules
The interface converter VAZ-R4-R2 is the ideal interface converter between the RS 232C interface of the PC and the RS 485 interface of the
AS-Interface Gateway.
The converter requires no additional external power supply. For this reason, it is highly suitable for mobile use on a laptop computer or note-
book.
The RS 232C/RS 485 converter is simply plugged between the AS-Interface Gateway and the RS 232 connection cable. Only one device with

Inductive sensors
an RS 485 interface can be connected up to the interface converter.
The RS 232C/RS 485 converter can be used on various operating systems. By means of the AS-i Control Tools for Windows an AS-Interface
Master with an RS 485 interface can be operated as well as an AS-Interface Master with an RS 232 interface. The RS 232C/RS 485 converter
supports all transmission rates up to 57600 Bit/s.
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 313
U-G1F

AS-Interface base U-G1F


Dimensions
Masters and
Gateways

80
Ø 9.6 26 36
Extender, Repeaters
Power Supplies,

18.5

31
45
18.5
Safety at work

66
36 26 Ø 5.3
Control cabinet

Electrical connection
I/O Modules

+
AS-Interface
-
Field application

+
I/O Modules

AS-Interface
-
Order code
U-G1F
Base for connection to flat cable
(EMS; AS-Interface only)
Analogue modules

Function + -
Contacts to module
The U-G1F base allows slaves in the normal
design to be connected to AS-Interface with-
out additional supply (EMS). It has two con-
Other modules

nection types for AS-Interface, which are


linterconnected. Thus it can be used as dis- Technical data
tributor from one AS-Interface segment to Ambient conditions
another. For the mounting of an upper part Ambient temperature -25 ... 60 °C (248 ... 333 K)
(module or cover VAZ-DK-G1) the flat cable Storage temperature -25 ... 85 °C (248 ... 358 K)
will be pressed into the contact prongs and Mechanical specifications
Inductive sensors

are thereby connected. Protection degree IP67 according to EN 60529


(only in connection with module or cover)
Connection 2 AS-Interface flat cables
Accessories
Dimensions about 80, 45, 20 mm (L, W, H)
VAZ-DK-G1 Mounting DIN rail or screw mounting
cover for bases -G1F- and -G1P-
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
314 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
U-G1FA

AS-Interface base U-G1FA


Dimensions

Masters and
Gateways
80
Ø 9.6 26 36

Extender, Repeaters
Power Supplies,
18.5

31
45
18.5

Safety at work
66
36 26 Ø 5.3

Control cabinet
Electrical connection

I/O Modules
+
AS-Interface
-

Field application
+

I/O Modules
AS-Interface
-
Order code
U-G1FA
Base with addressing jack for connec-
tion to flat cable

Analogue modules
(EMS; AS-Interface only)
ADDR
Function + -
Contacts to module
The U-G1FA base allows slaves in the nor-
mal design to be connected to AS-Interface
without additional supply (EMS). It has two

Other modules
connections to AS-Interface, which are inter-
connected. Thus it can also be used as dis- Technical data
tributor from one AS-Interface segment to General specifications
another. When mounting the upper part Addressing via addressing jack
(module or cover VAZ-DK-G1) the flat cable Ambient conditions
are pressed in the contact prongs and Ambient temperature -25 ... 60 °C (248 ... 333 K)

Inductive sensors
thereby connected. Storage temperature -25 ... 85 °C (248 ... 358 K)
Moreover, an integrated addressing jack can Mechanical specifications
configure the upper part in the wired AS-
Protection degree IP67 according to EN 60529
Interface network. In this case the controller (only in connection with module or cover)
indicates "Alarm Config", since the slave is Connection 2 AS-Interface flat cables
disconnected from the supply. After removing Dimensions about 80, 45, 20 mm (L, W, H)
the addressing plug, the controller restarts Mounting DIN rail or screw mounting
independently.
Photoelectric
sensors

Accessories
VAZ-DK-G1
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

cover for bases -G1F- and -G1P-


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 315
U-G1FF

AS-Interface base U-G1FF


Dimensions
Masters and
Gateways

80
Ø 9.6 26 36
Extender, Repeaters
Power Supplies,

18.5

31
45
18.5
Safety at work

66
36 26 Ø 5.3
Control cabinet

Electrical connection
I/O Modules

+
AS-Interface
-
Field application

External +
I/O Modules

auxiliary
-
Order code power

U-G1FF
Base for connection to flat cable
(EEMS; AS-Interface and external aux-
Analogue modules

iliary power)

Function + - + -
Contacts to module
The U-G1FF base allows to connect slaves
with additional supply (EEMS) to AS-Inter-
face. It has one connection type for AS-Inter-
Other modules

face and an other for the auxiliary power,


which are not interconnected. For the mount- Technical data
ing of an upper part (module or lid VAZ-DK- Ambient conditions
G1) the flat cable will be pressed in the con- Ambient temperature -25 ... 60 °C (248 ... 333 K)
tact prongs and so connected. Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications
Inductive sensors

Accessories Protection degree IP67 according to EN 60529


(only in connection with module or cover)
VAZ-DK-G1 Connection Flat cable for AS-Interface and external power supply
cover for bases -G1F- and -G1P- Dimensions about 80, 45, 20 mm (L, W, H)
Mounting DIN rail or screw mounting
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
316 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
U-G1FFA

AS-Interface base U-G1FFA


Dimensions

Masters and
Gateways
80
Ø 9.6 26 36

Extender, Repeaters
Power Supplies,
18.5

31
45
18.5

Safety at work
66
36 26 Ø 5.3

Control cabinet
Electrical connection

I/O Modules
+
AS-Interface
-

Field application
External +

I/O Modules
auxiliary
-
Order code power

U-G1FFA
Base with addressing jack for connec-
tion to flat cable (EEMS; AS-Interface

Analogue modules
and external auxiliary power)
ADDR

Function + - + -
Contacts to module
The U-G1FFA base allows slaves to be con-
nected to AS-Interface with additional supply
(EEMS). It has one connection type to AS-

Other modules
Interface and an other one to auxiliary power,
which are not interconnected. When mount- Technical data
ing the upper part (module or cover VAZ-DK- General specifications
G1) the flat cable will be pressed in the con- Addressing via addressing jack
tact prongs and are thereby connected. Ambient conditions
Moreover, an integrated addressing jack can Ambient temperature -25 ... 60 °C (248 ... 333 K)

Inductive sensors
be used to configure the upper part in the Storage temperature -40 ... 85 °C (233 ... 358 K)
wired AS-Interface network. In this case, the Mechanical specifications
controller indicates "Alarm Config", since the Protection degree IP67 according to EN 60529
slave is disconnected from the supply. After (only in connection with module or cover)
removing the addressing plug, the controller Connection Flat cable for AS-Interface and external power supply
restarts independently. Dimensions about 80, 45, 20 mm (L, W, H)
Mounting DIN rail or screw mounting
Accessories
Photoelectric
sensors

VAZ-DK-G1
cover for bases -G1F- and -G1P-
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 317
U-G1P

AS-Interface base U-G1P


Dimensions
Masters and
Gateways

80
Ø 9.6 62
Extender, Repeaters
Power Supplies,

45

31
37

Ø 5.3
21
Safety at work

22
66
Control cabinet

Electrical connection
I/O Modules


+

AS-Interface
Field application

-
I/O Modules

-
Order code
U-G1P
Base for connection to round cable
(EMS; AS-Interface only)
Analogue modules

Function + -
Contacts to module
The base U-G1P allows to connect slaves in
the normal design without additional supply
(EMS) to AS-Interface. It has two connection
Other modules

types for AS-Interface, which are linked with


each other. Thus it can be used as distributor Technical data
from one AS-Interface segment to another. Ambient conditions
The cable bushings are designed for round Ambient temperature -25 ... 60 °C (248 ... 333 K)
cables, they can be connected by screw ter- Storage temperature -25 ... 85 °C (248 ... 358 K)
minals. Mechanical specifications
Inductive sensors

Protection degree IP67 according to EN 60529


(only in connection with module or cover)
Accessories
Connection round cable PG11 for AS-Interface
VAZ-DK-G1 core cross-section ≤ 2.5 mm
cover for bases -G1F- and -G1P- Dimensions about 80, 45, 34 mm (L, W, H)
Mounting DIN rail or screw mounting
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
318 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
U-G1PP

AS-Interface base U-G1PP


Dimensions

Masters and
Gateways
80
Ø 9.6 62

Extender, Repeaters
Power Supplies,
45

31
37

Ø 5.3
21

Safety at work
22
66

Control cabinet
Electrical connection

I/O Modules
+
AS-Interface

-

Field application
+

I/O Modules
External
auxiliary power -
Order code
U-G1PP
Base for connection to round cable
(EEMS; AS-Interface and external aux-

Analogue modules
iliary voltage)

Function + - + -
Contacts to module
The base U-G1PP allows to connect slaves
with additional supply (EEMS) to AS-Inter-
face. It has one connection type to AS-Inter-

Other modules
face and an other to the auxiliary power,
which are not interconnected. The cable Technical data
bushings are designed for round cables, they Ambient conditions
can be connected by screw terminals. Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)

Accessories Mechanical specifications

Inductive sensors
Protection degree IP67 according to EN 60529
VAZ-DK-G1 (only in connection with module or cover)
cover for bases -G1F- and -G1P- Connection round cable PG11 for AS-Interface and external power supply
core cross-section ≤ 2.5 mm
Dimensions about 80, 45, 34 mm (L, W, H)
Mounting DIN rail or screw mounting
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 319
U-G2FF

AS-Interface base U-G2FF


Dimensions
Masters and
Gateways

112
77.5
4
Extender, Repeaters
Power Supplies,

48
PE
Safety at work

12
Control cabinet

Electrical connection
I/O Modules

+
AS-Interface
-
Field application

External +
I/O Modules

auxiliary
-
Order code power

U-G2FF
Mounting plate for connection to flat ca-
ble (AS-Interface and external auxiliary
Analogue modules

power)

Function + - + -
Contacts to module
The U-G2FF base is used for the connection
of the G2 modules with long design to AS-
Interface. In case of mounting the module the
Other modules

inserted flat cables are pressed into the con-


tact prongs of the module and connected. Technical data
For some modules this upper part estab- Ambient conditions
lishes the connection to earth. Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Inductive sensors

Protection degree IP67 according to EN 60529


(only in connection with module or cover)
Connection AS-Interface flat cable
Dimensions about 80, 45, 34 mm (L, W, H)
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
320 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
U-G3FF

AS-Interface base U-G3FF


Dimensions

Masters and
Gateways
112
77.5
4

Extender, Repeaters
Power Supplies,
48
PE

Safety at work
12

Control cabinet
Electrical connection

I/O Modules
+
AS-Interface
-

Field application
External +

I/O Modules
auxiliary
-
Order code power

U-G3FF
Mounting plate for connection to flat ca-
ble (AS-Interface and external auxiliary

Analogue modules
power)

Function + - + -
Contacts to module
The U-G3FF base is used for the connection
of the G2 modules with small design to AS-
Interface. In case of mounting the module the

Other modules
inserted flat cables are pressed into the con-
tact prongs of the module and connected. Technical data
For some modules this upper part estab- Ambient conditions
lishes the connection to earth. Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications

Inductive sensors
Protection degree IP67 according to EN 60529
(only in connection with module or cover)
Connection AS-Interface flat cable
Dimensions about 119, 60, 10 mm (L, W, H)
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 321
VAZ-DK-G1

AS-Interface Accessories

Order code
Masters and
Gateways

VAZ-DK-G1
cover for bases -G1F- and -G1P-

Mechanical specifications
Extender, Repeaters

Dimensions about 80, 45, 8 mm (L, W, H)


Power Supplies,
Safety at work

Order code
Control cabinet

VAZ-FK-ED-G2
I/O Modules

AS-Interface end seal for G2 modules

Mechanical specifications
Protection degree IP65 according to EN 60529
Field application
I/O Modules
Analogue modules

Order code
VAZ-FK-ST1
AS-Interface-flat cable sleeve, expandable hose
Other modules

Mechanical specifications
Protection degree IP65 according to EN 60529
Inductive sensors
Photoelectric
sensors

Order code
VAZ-FK-CL1
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Fixing clip for AS-Interface flat cable


Rotary encoders

Mechanical specifications
Mounting Adhesive or screw mounting
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
322 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-T1-FK-1M-PUR-V1-W

AS-Interface Accessories

Order code

Masters and
Gateways
VAZ-T1-FK-*M-PUR-V1-W
Splitter box AS-Interface to M12 round connector

General specifications

Extender, Repeaters
Construction type Socket, angled

Power Supplies,
flat cable terminal AS-Interface
Ambient conditions
Ambient temperature -20 ... 70 °C (253 ... 343 K)
Mechanical specifications
Protection degree IP67 according to EN 60529
Connection AS-Interface flat cable: cable piercing method

Safety at work
Connector: M12 x 1 (V1)
Material
Contacts CuZn
Contact surface Au / Sn
Housing PUR, black
Handle PUR, black
Cable PUR

Control cabinet
I/O Modules
Cable
Sheath diameter Ø6.8 mm
Cores 2 x 1.5 mm2
Length L VAZ-T1-FK-1M-PUR-V1-W: 1 m
VAZ-T1-FK-2M-PUR-V1-W: 2 m

Field application
I/O Modules
Analogue modules
Order code
VAZ-T1-FK-*M-PUR-V1-G
Splitter box AS-Interface to M12 round connector

Other modules
General specifications
Construction type Socket, straight
Flat cable terminal AS-Interface
Ambient conditions
Ambient temperature -20 ... 70 °C (253 ... 343 K)

Inductive sensors
Mechanical specifications
Protection degree IP67 according to EN 60529
Connection AS-Interface flat cable: cable piercing method
Connector: M12 x 1 (V1)
Material
Contacts CuZn
Contact surface Au / Sn
Photoelectric
sensors

Housing PUR, black


Handle PUR, black
Cable PUR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Cable
Sheath diameter Ø6.8 mm
2 x 1.5 mm2
Rotary encoders

Cores
Length L VAZ-T1-FK-0,3M-PUR-V1-G: 0.3 m
VAZ-T1-FK-1M-PUR-V1-G: 1 m
VAZ-T1-FK-2M-PUR-V1-G: 2 m
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 323
VAZ-2T1-FK-1M-PUR-V1-W

AS-Interface Accessories

Order code
Masters and
Gateways

VAZ-2T1-FK-*M-PUR-V1-W
Splitter box AS-Interface and auxiliary voltage to 1 x M12 round connector

General specifications
Extender, Repeaters

Construction type Socket, angled


Power Supplies,

Flat cable terminals AS-Interface/ext. auxiliary voltage


Electrical specifications
Rated operational voltage Ue ≤ 40 V
Rated operational current Ie ≤4A
Ambient conditions
Ambient temperature -25 ... 75 °C (248 ... 348 K)
Safety at work

Storage temperature -40 ... 85 °C (233 ... 358 K)


Mechanical specifications
Protection degree IP65/IP67 in accordance with DIN 40050
Connection AS-Interface flat cable: Insulation penetration technol-
ogy
Flat cable ext. auxiliary voltage UAUX: Insulation pene-
tration technology
Control cabinet
I/O Modules

Plug connection: M12 socket x 1 (V1)


Material
Housing PA 6-GF-FR, blue
Cable PUR
Cable
Cores 4 x 0.34 mm2
Field application

Length L VAZ-2T1-FK-1M-PUR-V1-W: 1 m
I/O Modules

VAZ-2T1-FK-2M-PUR-V1-W: 2 m
Mass approx. 50 g without cable
Analogue modules

Order code
VAZ-2T1-FK-2M-PUR-V1-G
Splitter box AS-Interface and auxiliary voltage to 1 x M12 round connector
Other modules

General specifications
Construction type Socket, straight
Flat cable terminals AS-Interface/ext. auxiliary voltage
Electrical specifications
Rated operational voltage Ue ≤ 40 V
Inductive sensors

Rated operational current Ie ≤4A


Ambient conditions
Ambient temperature -25 ... 75 °C (248 ... 348 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications
Protection degree IP65/IP67 in accordance with DIN 40050
Photoelectric

Connection AS-Interface flat cable: Insulation penetration technol-


sensors

ogy
Flat cable ext. auxiliary voltage UAUX: Insulation pene-
tration technology
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Plug connection: M12 socket x 1 (V1)


Material
Housing PA 6-GF-FR, blue
Rotary encoders

Cable PUR
Cable
Cores 4 x 0.34 mm2
Length L 2m
Mass approx. 50 g without cable
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
324 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-T1-G2F

AS-Interface Accessories

Order code

Masters and
Gateways
VAZ-T1-G2F
Distributor from flat cable to round cable

Ambient conditions

Extender, Repeaters
Ambient temperature -25 ... 85 °C (248 ... 358 K)

Power Supplies,
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree IP52 according to EN 60529
Connection AS-Interface flat cable
round cable 0.14 ... 0.34 mm;
Ø 5 ... 6 mm
Dimensions about 48, 35, 13 mm (L, W, H)

Safety at work
Order code
VAZ-G6F-V1

Control cabinet
I/O Modules
Splitter box AS-Interface to 1x M12 round connector

Mechanical specifications
Protection degree IP67 according to EN 60529
Connection AS-Interface-flat cable,

Field application
M12 round connector

I/O Modules
Analogue modules
Order code
VAZ-G6F-W2M
Adapter flat cable to round cable including 2 m round cable

Other modules
Mechanical specifications
Core cross-section 2 x 1.5 mm2
Protection degree IP67 according to EN 60529
Connection AS-Interface-flat cable,
2 m standard round cable

Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 325
VAZ-T1-FK-V1

AS-Interface Accessories

Order code
Masters and
Gateways

VAZ-T1-FK-V1
Splitter box AS-Interface to 1x M12 round connector

Ambient conditions
Extender, Repeaters

Ambient temperature -25 ... 60 °C (248 ... 333 K)


Power Supplies,

Storage temperature -40 ... 85 °C (233 ... 358 K)


Mechanical specifications
Protection degree IP67 according to EN 60529
Connection AS-Interface flat cable,
connector M12 x 1
Pin 1 AS-Interface+, Pin 3 AS-Interface-
Dimensions about 50, 20, 30 mm (L, W, H)
Safety at work

Order code
Control cabinet

VAZ-T1-FK-V1-V4A
I/O Modules

Splitter box AS-Interface to 1x M12 round connector(high grade steel V4A)

Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Field application

Mechanical specifications
I/O Modules

Protection degree IP67 according to EN 60529


Connection AS-Interface flat cable,
connector M12 x 1
Pin 1 AS-Interface+, Pin 3 AS-Interface-
Dimensions about 50, 20, 30 mm (L, W, H)
Analogue modules

Order code
VAZ-T1-FK-V1-DIG
Rubber seal for AS-Interface passive distributor VAZ-T1-FK-V1
Other modules
Inductive sensors
Photoelectric
sensors

Order code
VAZ-T1-FK-W-PG7
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

AS-Interface splitter box


Rotary encoders

Ambient conditions
Ambient temperature -20 ... 70 °C (253 ... 343 K)
Mechanical specifications
Protection degree IP67 according to EN 60529
Connection AS-Interface flat cable
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
326 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-T1-FK-M20

AS-Interface Accessories

Order code

Masters and
Gateways
VAZ-T1-FK-M20
Screw adapter M20 x 1.5 with metal housing

Ambient conditions

Extender, Repeaters
Ambient temperature -25 ... 60 °C (248 ... 333 K)

Power Supplies,
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree IP65 according to EN 60529
Connection AS-Interface flat cable
Cable
Cores 2 x 0.25 mm2

Safety at work
Length L Lead length approx. 200 mm

Order code
VAZ-T1-FK-PG9

Control cabinet
I/O Modules
Screw adapter PG9

Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)

Field application
Mechanical specifications

I/O Modules
Protection degree IP67 according to EN 60529
Connection AS-Interface flat cable
Cable
Cores 2 x 0.25 mm2
Length L Lead length approx. 200 mm

Analogue modules
Order code
VAZ-T1-FK-PG11
Screw adapter PG11

Other modules
Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -25 ... 85 °C (248 ... 358 K)
Mechanical specifications
Protection degree IP67 according to EN 60529

Inductive sensors
Connection AS-Interface flat cable
Cable
Cores 2 x 0.25 mm2
Length L Lead length approx. 200 mm
Photoelectric
sensors

Order code
VAZ-PG11-FKD
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Seal for AS-Interface-flat cable in PG11 screwed connection


Rotary encoders

Mechanical specifications
Protection degree IP67 according to EN 60529
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 327
VAZ-T1-FK-CLAMP

AS-Interface Accessories

Order code
Masters and
Gateways

VAZ-T1-FK-CLAMP
Non pre-wired cable socket

Electrical specifications
Extender, Repeaters

Rated operational voltage Ue 31.6 V DC


Power Supplies,

Current loading capacity ≤3A


Ambient conditions
Ambient temperature -25 ... 55 °C (248 ... 328 K)
Mechanical specifications
Protection degree IP20
Connection Connection terminals, max. conductor cross-section
flexible: 0.5 ... 0.75 mm2 (AWG20 ... AWG18)
Safety at work

fixed: 0.5 ... 1.5 mm2 (AWG20 ... AWG16)


Stripped length 6 ... 8 mm,
Connector sleeve for flexible ends with 0.75 mm2 rec-
ommended
Mass approx. 9 g
Control cabinet
I/O Modules
Field application
I/O Modules
Analogue modules

Order code
VAZ-2FK-B1
Distributor for 2 AS-Interface-flat cable
Other modules

Ambient conditions
Ambient temperature -25 ... 60 °C (248 ... 333 K)
Storage temperature -40 ... 85 °C (233 ... 358 K)
Mechanical specifications
Protection degree IP65 according to EN 60529
Inductive sensors

Connection AS-Interface flat cable


Photoelectric
sensors

Order code
VAZ-PK-1,5M-V1-G
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Connection cable module/hand-held programming device


Rotary encoders

Mechanical specifications
Connection M12 for programming device and connector for
addressing socket on module
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
328 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-V1-B

AS-Interface Accessories

Order code

Masters and
Gateways
VAZ-V1-B
Blind plug for M12 sockets

Mechanical specifications

Extender, Repeaters
Connection M12 x 1

Power Supplies,
Safety at work
Order code
VAZ-V1-B1

Control cabinet
I/O Modules
Blanking plug for M12 addressing socket

Mechanical specifications
Connection M12 x 1

Field application
I/O Modules
Analogue modules
Order code
VAZ-V3-B
Blind plug for M8 sockets

Other modules
Mechanical specifications
Connection M8 x 1

Inductive sensors
Photoelectric
sensors

Order code
VAZ-G4-B
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Blind plug PG7


Rotary encoders

Mechanical specifications
Connection PG7
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 329
VAZ-SW-ACT32

AS-Interface Accessories

Order code
Masters and
Gateways

VAZ-SW-ACT32
Full version of the AS-i Control Tools

General specifications
Extender, Repeaters

Description Operating software for configuration, programming, AS-


Power Supplies,

Interface diagnosis and AS-Interface safety diagnosis


Safety at work

Order code
Control cabinet

VAZ-SW-SIMON
I/O Modules

Software for configuration of safety monitors, connecting cable VAZ-SIMON-R2

General specifications
Description Software on CD-ROM and connection cable
Field application
I/O Modules
Analogue modules

Order code
VAZ-SIMON-R2
Interface cable for connecting the safety monitor to a PC
Other modules

Mechanical specifications
Connection RS 232 interface, 2 m
Inductive sensors
Photoelectric
sensors

Order code
VAZ-SIMON-RJ45
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Interface cable for connecting two safety monitors


Rotary encoders

Mechanical specifications
Connection 2 x RJ45, 0.1 m
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
330 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
VAZ-TERM

AS-Interface Accessories

Order code

Masters and
Gateways
VAZ-TERM
passive bus termination

Input

Extender, Repeaters
Supply from AS-Interface

Power Supplies,
Input current ≤ 10 mA
Mechanical specifications
Protection degree IP67
Connection M12 connector, 4-pin
Note Purpose: improvement of signal quality and voltage
monitoring; operation on the most remote AS-Interface
strand (up to 200 m).

Safety at work
Maximum 1 repeater in line possible. When use of
repeater for each strand required.

Order code
VAZ-TUNER

Control cabinet
I/O Modules
Active bus terminal resistor

Input
Supply from AS-Interface
Input current ≤ 60 mA

Field application
Mechanical specifications

I/O Modules
Protection degree IP67
Connection cable piercing method or terminal compartment
flat cable or standard round cable
Note Purpose: improvement of signal quality and voltage
monitoring; operation on the most remote AS-Interface
strand (up to 300 m).

Analogue modules
Illustration similarly
When use of repeater for each strand required.

Order code
VAZ-FK-R-STRIPPER
Stripping pliers for AS-Interface flat cable

Other modules
Mechanical specifications
Material Body of tongs: Glass fibre-reinforced PA (Polyamide)
Mass approx. 120 g
Dimensions Tool length: approx. 160 mm

Inductive sensors
Photoelectric
sensors

Order code
VAZ-FK-S-STRIPPER
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Cable stripper for standard AS-Interface flat cable


Rotary encoders

Mechanical specifications
Mass approx. 50 g
Dimensions Tool length: approx. 125 mm
Note not suitable for PUR or TPE AS-Interface flat cable.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 331
VAZ-2T5-G2

AS-Interface splitter box VAZ-2T5-G2


Dimensions
Masters and
Gateways

66

29
Extender, Repeaters
Power Supplies,
Safety at work

60
Control cabinet

Electrical connection
I/O Modules

5 quick
disconnectors M12x1
AS-i + 1
Field application

AS-i +
I/O Modules

Order code AS-i - 3 1


AS-i -
VAZ-2T5-G2
AUX + 4 4 2
Splitter box AS-Interface and auxiliary AUX +
voltage to 5 x M12 round connector 5
Analogue modules

AUX - 2 3
AUX -

5
Features (nc)

• Less space required


• Field housing with protection class
IP67
Other modules

• Simple and fast mounting Technical data


• Distribution to 5 V1 connectors (M12) Indicators/operating means
LED AS-i AS-Interface voltage; dual LED green/red
• Function display with 2 LEDs green: voltage OK
red: reversed voltage
Inductive sensors

Function LED AUX ext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
The VAZ-2T5-G2 splitter box is used to
Ambient conditions
distribute the AS-i connection and the
external auxiliary power to five M12x1 quick Ambient temperature -25 ... 70 °C (248 ... 343 K)
disconnects. Due to its passivity the Storage temperature -25 ... 85 °C (248 ... 358 K)
distributor does not require an own address Mechanical specifications
on the AS-Interface. It is ideal for Protection degree IP67 according to EN 60529
Photoelectric

applications in the field owing to the Connection cable piercing method


sensors

protection class IP67. Two LEDs indicate flat cable yellow/flat cable black
inputs/outputs: M12 round connector
correct polarity of the AS-i cable or the
Mass 100 g
external auxiliary power.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Dimensions 80, 44, 24 mm


Note:
The mounting plate for the module is sold
Rotary encoders

separately.

Matching system components


U-G3FF
Mounting plate for connection to flat ca-
ble (AS-Interface and external auxiliary
Accessories

power)

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
332 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
333
Notes

Accessories Rotary encoders Photoelectric Inductive sensors Other modules Analogue modules I/O Modules I/O Modules Safety at work Power Supplies, Masters and
sensors Field application Control cabinet Extender, Repeaters Gateways
PR-05

Power Rail PR-05


Mechanischer Aufbau
Masters and
Gateways

1 lead for
collective
Extender, Repeaters

2 leads for bus connection error message


Power Supplies,

Power Rail 2 leads for


power supply
Safety at work

End cap
Control cabinet
I/O Modules

Connectors for coupling the


VE-PR power rail.
Field application
I/O Modules

DIN rail
Order code
PR-05
Power Rail with grid, 5 leads
Analogue modules

Features
• Alternative power supply
Technical data
• Nominal current 4 A
Electrical specifications
Other modules

• Simple installation Rated voltage 24 V DC


• Standard length 50 cm, can be Rated current 4A
shortened to any length in 4 cm steps Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K)
• Terminating insulation by end cap,
included in the delivery package Function
Inductive sensors

• with 2 leads for power supply, 2 leads


for bus connections and 1 lead for The Power Rail is a simple plastic insert for the standard rail in accordance with
centralised error messages or HART EN 50022. It solves all of the power supply wiring problems involved when moun-
signal transfer (with RPI-system) ting terminal blocks.
A wide range of interface modules is available. These are supplied with auxiliary po-
Accessories wer by simply snapping them onto the Power Rail. The supply of power to the 2 Po-
wer Rail leads is achieved either by means of a power supply module, or via the
VE-PR
Photoelectric

terminal strip of a motherboard.


sensors

Linking connector element for PR-03 and By comparison, the interface module power supply connections are only suitable for
PR-05 the supply of the individual modules. They are not suitable for the supply of the Po-
wer Rail or to further conduct the Power Rail voltage.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

On the PR-05 Power Rail, 2 additional poles are available for the bus connection of
the interface modules.
Rotary encoders

The Power Rail is supplied in 50 cm sections. It can be cut every 4 cm along its
length, at the positions indicated, to suit individual requirements. Gold plated con-
tacts are provided to ensure secure electrical contact.
Please use the standard item UPR-05 for new systems.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
334 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
UPR-05

Universal Power Rail UPR-05


Mechanischer Aufbau

Masters and
Gateways
2 leads for power supply 1 lead for
collective
error message
Cover

Extender, Repeaters
Power Supplies,
2 leads for bus
connection

Universal Power Rail

Safety at work
Mount using M4
screws with
washers per
DIN 125
End cap UPR-E

DIN rail

Control cabinet
35 mm x 15 mm

I/O Modules
Slot mounted Power Rail

Field application
I/O Modules
Order code
UPR-05
Universal Power Rail with DIN rail and
cover, 5 leads

Analogue modules
Technical data
Electrical specifications
Features Rated voltage 24 V DC
Rated current 4A
• Alternative power supply
Ambient conditions
• Nominal current 4 A Ambient temperature -20 ... 60 °C (253 ... 333 K)

Other modules
• Standard length 2 m, can be
Function
shortened to any length
• with 2 leads for power supply, 2 leads The universal Power Rail is a plastic insert that has been specifically designed to
for bus connections and 1 lead for seat into the DIN rail. Devices that can be mounted on a standard rail in accordance
centralised error messages or HART with EN 50022, can easily be mounted on the DIN rail.
signal transfer (with RPI-system) The Power Rail has 2 leads for supplying the modules with power, 1 lead for cen-

Inductive sensors
tralised error messages and 2 leads for bus connection. These 2 leads are used on
Accessories Remote Process Interface, for the internal bus system, for the transfer of digital in-
formation. The KF-series and Remote Process Interface devices are supplied with
UPR-E
power via the 2 leads. Gold plated contacts are provided to ensure secure electrical
End cap for UPR-03 und UPR-05
contact. The UPR-05 do not feature "segmental" construction. Modules of any width
can be mounted on these rails. This ensures that it will be possible to mount future
component designs on the same rail. The TS35 type 12 end terminal is used as a
Photoelectric
sensors

termination when the devices are mounted vertically. The cover serves as a means
of mechanical and electrical protection for exposed leads. It is possible to remove
the installed Power Rail from the DIN rail using the UPR-E end cap.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

The universal Power Rail, the cover and the DIN rail are delivered in a standard
length of 2 m and can be cut with a saw to any required length.
Rotary encoders

Delivery package:
Universal Power Rail, aluminium DIN rail, cover, 2 UPR-E end caps. The UPR-E
end caps can be ordered separately (in packs of 10).
Please use this standard type for new systems.
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 335
Photoelectric I/O Modules I/O Modules Power Supplies, Masters and
Accessories Rotary encoders sensors Inductive sensors Other modules Analogue modules Field application Control cabinet Safety at work Extender, Repeaters Gateways

336
Notes

Subject to reasonable modifications due to technical advances.


Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Copyright Pepperl+Fuchs, Printed in Germany
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
AS-Interface - Mating, connectors and cable

10 Mating connectors and cable

Masters and
Gateways
Screw terminal connectors in M8, M12, M18 and Rd24 x 1/8:
V... screw terminal connectors
Design

Number of Strand size


Model number Design Connector type Fig.
pins (mm2)

Extender, Repeaters
Power Supplies,
V3-GM Socket, straight Insulation piercing 3-pin 0.25 ... 0.34 1
M8

V3-WM Socket, angled Insulation piercing 3-pin 0.25 ... 0.34 2


V3S-GM Connector, straight Insulation piercing 3-pin 0.25 ... 0.34 -
V1-G Socket, straight 4-pin max. 0.75 3
V1-W Socket, angled 4-pin max. 0.75 4

Safety at work
V1-WV2A Socket, angled Screw terminal, PG7 screw 4-pin max. 0.75 -
V1S-G Connector, straight 4-pin max. 0.75 -
V1S-W Connector, angled 4-pin max. 0.75 -
M12

LED board suitable for installation in


V1-E/E2-LED - - -
(NPN/PNP in one board) V1-G and V1-W

Control cabinet
V1-G-Q2 Socket, straight Insulation piercing 4-pin 0.34 ... 0.75 5

I/O Modules
V1S-G-Q2 Connector, straight Insulation piercing 4-pin 0.34 ... 0.75 -
V15-W-PG9 Socket, straight Screw terminal 5-pin max. 0.75 -
V1S-G-DUO-PG11 Connector, straight Screw terminal 4-pin max. 0.75 -
Rd24 x 1/8

V16-G Socket Rd24 x 1/8, straight Screw terminal 6-pin + PE max. 0.75 6

Field application
V16-W Socket Rd24 x 1/8, angled Screw terminal 6-pin + PE max. 0.75 -

I/O Modules
V16S-G Connector Rd24 x 1/8, straight Screw terminal 6-pin + PE max. 0.75 -
V18-G Socket, straight Screw terminal 4-pin max. 1.5 7
M18

V18-W Socket, angled Screw terminal 4-pin max. 1.5 8


With central screw

V-W Socket with central screw, angled Screw terminal 5-pin max. 2.5 -

Analogue modules
Screw terminal, with integrated
V-W-E2 Socket with central screw, angled 5-pin max. 2.5 -
LED

V-W-N Socket with central screw, angled Screw terminal 5-pin max. 2.5 -

Y distributors in M12

Other modules
Design

Number of Strand size


Model number Design Connector type Fig.
pins (mm2)

V1S-T-V1 1 x M12 connector, straight


M12 connector 3-pin - 9
V1S-T-V1
2 x M12 socket, straight
M12

Inductive sensors
5-pin
V15S-T-V15 1 x M12 connector, straight
M12 connector (Pins 2 and 4 - 9
V15S-T-V15
2 x M12 socket, straight
bridged)

Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Photoelectric


sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Fig. 6 Fig. 7 Fig. 8 Fig. 9


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 337
AS-Interface - Mating, connectors and cable
Technical data for connectors with sprayed cables
Masters and

Connectors and sockets


Gateways

Number of pins 2-, 3-, 4- or 5-pin


Locking Screw lock
Extender, Repeaters

Self-locking via O-ring in cap nut


Power Supplies,

Grip color green


Grip material PUR
Contact material CuSn/Au
Contact surface material Au
Safety at work

Cap nut material CuSn/Ni


Gasket material NBR
DIN 40050 protection class IP68 when screwed down
Max. operating voltage 60 V DC or 250 V AC (for V13-... types)
Max. operating current 4A
Control cabinet
I/O Modules

Volume resistance < 5 mΩ


Insulation resistance as specified in VDE 0295
Test voltage 1500 Veff. AC, 50 Hz
Field application

Cable
I/O Modules

Cable structure fine wire, flexible


Wire size Cables for M12 connection: 0.34 mm2
Cables for M8 connection: 0.25 mm2
Analogue modules

gray
Temperature range for PVC cables moving: -5 °C ... +70 °C
non-moving: -30 °C ... +80 °C
Temperature range for PUR cables 1) moving: -5 °C ... +70 °C
non-moving: -30 °C ... +105 °C
Minimum permissible bending radius > 10 x cable diameter, drag line suitable
Other modules

Sheath diameter ∅4,6 mm for M8 and ∅4,8 mm for M12,


but ∅5,2 mm for 5-pin version
Strand insulation material PVC or polyester-type plastic for halogen-free cables
Wire colours as specified in VDE 293 2-pin BN, BU
Inductive sensors

3-pin BN, BU, BK


4-pin BN, BU, BK, WH
5-pin BN, BU, BK, WH, GY (GN/YE for PE)

1)
Please note reduced mechanical values for PUR cables at temperatures over +80 °C.

Socket dimensions
Photoelectric
sensors

V1... V1... V3... V3...


straight ø14,5 angled straight angled
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

ø10
27
20
Rotary encoders

48,2

33
38

28
L

L
L
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
338 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Mating, connectors and cable
Cable sockets in M8 style with metallic cap nuts 1)
V3-... cable sockets

Masters and
V31-... cable sockets

Gateways
Suitable for 2-, 3-, and
4-wire sensors

4 (BK) 4 2
(BK) (WH)

Extender, Repeaters
1

Power Supplies,
3
(BU) (BN) 3 1
(BU) (BN)

Number Ø Design
Cable Design Design
Length of angled
sheath
strands (mm2) straight angled
with 2 LEDs

Safety at work
2m 3 0,25 V3-GM-2M-PUR V3-WM-2M-PUR V3-WM-E2-2M-PUR
PUR, gray 5m 3 0,25 V3-GM-5M-PUR V3-WM-5M-PUR V3-WM-E2-5M-PUR
10 m 3 0,25 V3-GM-10M-PUR V3-WM-10M-PUR V3-WM-E2-10M-PUR
2m 3 0,25 V3-GM-2M-PVC V3-WM-2M-PVC

Control cabinet
PVC, gray 5m 3 0,25 V3-GM-5M-PVC V3-WM-5M-PVC V3-WM-E2-5M-PVC

I/O Modules
10 m 3 0,25 V3-GM-10M-PVC V3-WM-10M-PVC
2m 4 0,25 V31-GM-2M-PUR V31-WM-2M-PUR
PUR, gray 5m 4 0,25 V31-GM-5M-PUR V31-WM-5M-PUR
10 m 4 0,25 V31-GM-10M-PUR V31-WM-10M-PUR

Field application
I/O Modules
2m 4 0,25 V31-GM-2M-PVC V31-WM-2M-PVC
PVC, gray 5m 4 0,25 V31-GM-5M-PVC V31-WM-5M-PVC
10 m 4 0,25 V31-GM-10M-PVC V31-WM-10M-PVC

Analogue modules
1)
M8 cable sockets with ratchet lock upon request.

Cable sockets in M12 style for NAMUR sensors


V1-... cable sockets

Suitable for NAMUR sensors


Grips and cable sheaths
in blue

Other modules
1(BN) 1(BN)

2 (BU) 4 2
(BK) (WH)

3(BU)

Inductive sensors
Number Ø
Cable Design Design
Length of
sheath
strands (mm2) straight angled

2m 4 0,34 V1-W-N4-2M-PVC
PVC, blue 5m 4 0,34 V1-W-N4-5M-PVC
10 m 4 0,34 V1-W-N4-10M-PVC
Photoelectric
sensors

2m 2 0,34 V1-G-N-2M-PUR V1-W-N-2M-PUR


PUR, blue 5m 2 0,34 V1-G-N-5M-PUR V1-W-N-5M-PUR
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

10 m 2 0,34 V1-G-N-10M-PUR V1-W-N-10M-PUR


5m 4 0,34 V1-G-N4-5M-PUR
Rotary encoders

PUR, blue
10 m 4 0,34 V1-G-N4-10M-PUR
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 339
AS-Interface - Mating, connectors and cable
Cable sockets in M12 style for DC sensors
V15-... cable sockets
Masters and

V11-... cable sockets


Gateways

Suitable for 2-, 3-, and

4-wire DC sensors
1(BN) 1(BN)
Extender, Repeaters
Power Supplies,

4 2 4 2
(BK) (WH) (BK) (WH)
5
3(BU) (GR)
3(BU)
Number Ø Design
Cable Design Design
Length of angled
sheath
strands (mm2) straight angled
with LEDs
Safety at work

2m 3 0,34 V11-G-2M-PVC V11-W-2M-PVC


PVC, gray 5m 3 0,34 V11-G-5M-PVC V11-W-5M-PVC
10 m 3 0,34 V11-G-10M-PVC V11-W-10M-PVC
2m 4 0,34 V1-G-2M-PVC V1-W-2M-PVC
Control cabinet

PVC, gray 5m 4 0,34 V1-G-5M-PVC V1-W-5M-PVC


I/O Modules

10 m 4 0,34 V1-G-10M-PVC V1-W-10M-PVC


2m 5 0,34 V15-G-2M-PVC V15-W-2M-PVC
PVC, gray 5m 5 0,34 V15-G-5M-PVC V15-W-5M-PVC
10 m 5 0,34 V15-G-10M-PVC V15-W-10M-PVC
Field application
I/O Modules

2m 3 0,34 V11-W-2M-PUR V1-W-E2-2M-PUR


5m 3 0,34 V11-W-5M-PUR V1-W-E2-5M-PUR
PUR, gray
V1-W-E-5M-PUR
10 m 3 0,34 V11-W-10M-PUR V1-W-E2-10M-PUR
Analogue modules

2m 4 0,34 V1-G-2M-PUR V1-W-2M-PUR V1-W-A2-2M-PUR


5m 4 0,34 V1-G-5M-PUR V1-W-5M-PUR V1-W-A2-5M-PUR
PUR, gray V1-A0-5M-PUR
V1-W-E2/E3-5M-PUR
10 m 4 0,34 V1-G-10M-PUR V1-W-10M-PUR V1-W-A2-10M-PUR
Other modules

2m 5 0,25 V15-W-2M-PUR
PUR, gray
5m 5 0,25 V15-W-5M-PUR V1-W-A2-5M-PUR

Cable sockets in M12 style with radiation-crosslinked cable


Suitable for 2-, 3-, and 4-wire DC sensors,
Inductive sensors

radiation-crosslinked cable in halogen-free


version or with PE
1(BN) 1(BN)

4 2 4 2
(BK) (WH) (BK) (WH)
5
Photoelectric

3(BU) 3(BU) (GN/YE)


sensors

Number Ø Design
Design Design
Cable sheath Length of angled
(mm2) straight angled
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

strands with LEDs


PUR, halogen- 2m 4 0,34 V1-G-2M-PUR H/S V1-W-2M-PUR H/S V1-W-A2-2M-PUR H/S
Rotary encoders

free, radiation-
5m 4 0,34 V1-G-5M-PUR H/S V1-W-5M-PUR H/S V1-W-A2-5M-PUR H/S
crosslinked,
orange 10 m 4 0,34 V1-G-10M-PUR H/S V1-W-10M-PUR H/S
PUR, radiation- 2m 4+1 0,34 V15-G-2M-PUR S/PE V15-W-2M-PUR S/PE V15-G-A2-2M-PUR S/PE
crosslinked
5m 4+1 0,34 V15-G-5M-PUR S/PE V15-W-5M-PUR S/PE V15-G-A2-5M-PUR S/PE
with PE,
orange
Accessories

All connector cables and cable connector versions are also available with radiation-crosslinked cables.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
340 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Mating, connectors and cable
Cable sockets in M12 style for AC sensors
V13-... cable sockets

Masters and
Gateways
Suitable for 2-wire
AC sensors
1(GN/YE)

Extender, Repeaters
3 2

Power Supplies,
(BN) (BU)

Number Ø Design Design


Cable sheath Length of
strands (mm2) straight angled

Safety at work
PUR, black 5m 3 0,34 V13-G-5M-PUR V13-W-5M-PUR

Cable sockets in Rd24 x 1/8 style, suitable for F31 double sensors
V16-... cable sockets

Control cabinet
Suitable for connection to

I/O Modules
F31 line with V16 system connectors
4 3

5 2
6 1

Field application
I/O Modules
Number Ø
Cable Design
Length of
sheath
strands (mm2) straight

5m 6 0,75 V16-G-N4-5M-PVC

Analogue modules
PVC, blue
10 m 6 0,75 V16-G-N4-10M-PVC

Other modules
Inductive sensors
Photoelectric
sensors
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 341
AS-Interface - Mating, connectors and cable
Cable connectors in M8 style
V3S-... cable connector
Masters and

V31S-... cable connector


Gateways

Suitable for 2-, 3-, and 4-wire DC sensors with


terminal compartment for connection to a
junction box
4 BK
2 WH 4 BK
Extender, Repeaters
Power Supplies,

1 BN 3 BU
1 BN 3 BU

Number Ø
Cable Design Design
Length of
sheath
strands (mm2) straight angled
Safety at work

2m 3 0,25 V3S-GM-2M-PUR V3S-WM-2M-PUR


PUR
5m 3 0,25 V3S-GM-5M-PUR V3S-WM-5M-PUR
2m 4 0,25 V31S-GM-2M-PUR V31S-WM-2M-PUR
PUR
5m 4 0,25 V31S-GM-5M-PUR V31S-WM-5M-PUR
Control cabinet
I/O Modules

Cable connectors in M12 style


V1S-... cable connector

Suitable for all DC sensors with terminal


compartment for connection to a junction box
Field application
I/O Modules

1 BN

2 WH 4 BK

3 BU
Analogue modules

Number Ø
Cable Design Design
Length of
sheath
strands (mm2) angled straight

2m 4 0,34 V1S-W-2M-PVC V1S-G-2M-PVC


PVC, gray 5m 4 0,34 V1S-W-5M-PVC V1S-G-5M-PVC
Other modules

10 m 4 0,34 V1S-W-10M-PVC V1S-G-10M-PVC


2m 4 0,34 V1S-W-2M-PUR V1S-G-2M-PUR
PUR, gray 5m 4 0,34 V1S-W-5M-PUR V1S-G-5M-PUR
10 m 4 0,34 V1S-W-10M-PUR V1S-G-10M-PUR
Inductive sensors
Photoelectric
sensors

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005


Rotary encoders
Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
342 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Mating, connectors and cable
M12 connection cable from M12 to M12, sheath colour gray

Masters and
Gateways
Suitable for
all 2-, 3-, and 4-wire DC sensors

Extender, Repeaters
Power Supplies,
Numbe Ø
Length r of Socket, straight Socket, angled
strands (mm2)

Safety at work
0,6 m 4 0,34 V1-G-0,6M-PUR-V1-G xV1-W-0,6M-PUR-V1-G
0,6 m 4 0,34 V1-G-0,6M-PVC-V1-G V1-W-0,6M-PVC-V1-G
1m 4 0,34 V1-G-1M-PUR-V1-G V1-W-1M-PUR-V1-G
1m 4 0,34 V1-G-1M-PVC-V1-G V1-W-1M-PVC-V1-G
Connec-
2m 4 0,34 V1-G-2M-PUR-V1-G V1-W-2M-PUR-V1-G

Control cabinet
tor,

I/O Modules
straight 2m 4 0,34 V1-G-2M-PVC-V1-G V1-W-2M-PVC-V1-G
5m 4 0,34 V1-G-5M-PUR-V1-G V1-W-5M-PUR-V1-G
5m 4 0,34 V1-G-5M-PVC-V1-G V1-W-5M-PVC-V1-G
Connec- 1m 4 0,34 V1-W-E2-1M-PUR-V1-G

Field application
tor,

I/O Modules
2m 4 0,34 V1-W-E2-2M-PUR-V1-G
straight,
with LED 5m 4 0,34 V1-W-E2-5M-PUR-V1-G

These connector cables can be used together with 2-, 3-, and 4-wire DC proximity switches.

Analogue modules
V11-... connection cable
V1-... connection cable

M12 connection cable from M12 to M12, three-stranded, sheath colour gray

Other modules
Suitable for
connection of 4-strand sensors to AS Interface modules for
prevention of short circuits on signal inputs

Inductive sensors
Numbe Ø
Length r of Socket, straight Socket, angled
strands (mm2)

1m 3 0,34 V11-G-1M-PUR-V11-G V11-W-1M-PUR-V11-G


1m 3 0,34 V11-G-1M-PVC-V11-G V11-W-1M-PVC-V11-G
2m 3 0,34 V11-G-2M-PUR-V11-G V11-W-2M-PUR-V11-G
Photoelectric
sensors

Connec- 2m 3 0,34 V11-G-2M-PVC-V11-G V11-W-2M-PVC-V11-G


tor,
straight 5m 3 0,34 V11-G-5M-PUR-V11-G V11-W-5M-PUR-V11-G
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

5m 3 0,34 V11-G-5M-PVC-V11-G V11-W-5M-PVC-V11-G


Rotary encoders

Pin 2 is unused in these connector cables.


Accessories

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 343
Notes

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
344 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Training Kit

11 AS-Interface Training Kit


The AS-Interface training kit imparts the basics of topics relevant to the
bus system, such as the master/slave principle, addressing topics, behavior
of the system with failing nodes, and so on. Of course, more in-depth AS-
Interface knowledge is also included.

The core of the training kit is an AS-Interface master with enhanced control
and PLC functionality (max. 16 kB command memory, with 8 kB registers,
1024 timers, and 1024 counters), with which control programs can be proc-
essed over the AS-Intervace as a stand-alone.
Along with the AS-Interface training kit, the trainee has a set of equipment
available with which the functionality and possibilities of the AS-Interface
can be explored. The complete training kit includes a task collection com-
prising some 50 tasks, which increase in difficulty as the user progresses.
It provides trainees with a step-by-step introduction to AS-Interface. For fur-
ther support of the training, about 45 overhead slides are included, covering
a range of topics. The commissioning software, along with the slides in
PowerPoint® format on CD, are included in the training kit.

Order # with snap-in Order # with


Items Description
fasteners plugs
AS-Interface training kit with standard master, without case 1 827 003 632 1 827 003 198
1 AS-Interface Control Master with RS232 interface 1 827 003 672 1 827 003 972
1 Power Extender (replaces the AS-Interface power supply 1 827 003 066 1 827 003 066
2 Inductive AS-Interface Sensors 1 827 003 071 1 827 003 971
1 2EA module [for connection of two non-AS-Interface-ready sensors (E) 1 827 003 644 1 827 003 644
and actuators (A)]
2 inductive two-wire sensors 1 827 003 532 1 827 003 932
2 Test leads, yellow 1 827 003 523 1 827 003 523
2 Test leads, black 1 827 003 143 1 827 003 143
1 AS-Interface flat cable, yellow 1 827 003 068 1 827 003 068
1 AS-Interface flat cable, black 1 827 003 069 1 827 003 069
2 Connector for connection of sensors/actuators to the 2EA module 1 827 003 070 1 827 003 070
Option
1 Bus monitor (hardware checker) including connector cables 1 827 003 658 1 827 003 658

The AS-Interface training kit has been designed to be compatible with the
SENSORIK training package. This means that either the kit or the bread-
board can be used as work area. The sensors from the SENSORIK training
package are compatible with the 2EA module.
AS-Interface training kit with The training kit can be extended on request with gateways for connection
PROFIBUS DP gateway and to higher-level systems. This provides an opportunity to drive the AS-In-
PROFIBUS simulator terface and the SENSORIK training kits directly from a bus system. Gate-
ways for the PROFIBUS DP, InterBus, CANopen, DeviceNet, Modbus, and
other bus systems are available on request. Included in the training kit is a
professional commissioning software package including a converter. Using
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

the commissioning software and the converter, any gateway can be ad-
dressed over the RS 232 interface of any PC. The gateways can also be
driven as slaves from the corresponding field bus systems.
For AS-Interface specification 2.1, there is a separate training kit. Using this
AS-Interface training kit training packages AS-Interface per specification 2.1, the particular fea-
per specification 2.1 tures of the new AS-Interface geenration (for instance, A/B addressing, an-
with PROFIBUS DP gateway alogue value transmission) can be learned.
and PROFIBUS simulator

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 345
AS-Interface - Additional Information
12 Additional Information

12.1 Glossary
Address Gateway
Identifies a slave. On AS-Interface slaves, the factory A master, which also manages the connection to a
setting is 0. The address is automatically set to the re- higher-level bus. In this sense, it functions as a slave.
quired value (between 1 and 31) in the system. It can
ID code
be changed at any time. Identifies the slave type. The ID code is specified by
Actuator the slave manufacturer and cannot be modified.
A device which is externally controled and executes a Hamming distance (HD)
simple movement. For example: Magnetic switch, The HD specifies how many errors (e) a code can de-
valve. Sensor (antonym). One sometimes also sees tect depending on its error detection algorithm (HD = e
the word "actor", for instance in the AS-Interface brand + 1). The HD only relates to error detection in messag-
name. es. Usually, fieldbus HD = 4.
Analogue module Configuration data
A module for connecting analogue I/O signals, e.g. Image of an actual slave on AS-Interface
voltage, current, temperature resistance detector. Da- (= actual status of an AS-Interface network). The con-
ta transfer is obtained from Profile 7.3. figuration data (I/O, ID) is stored in the list of detected
Coupling module slaves (LDS).
A device which, on the bus side, behaves like an AS- Master
Interface slave. On the other side it can supply power Higher-level control unit on bus systems.
to four binary actuators or sensors which are not bus-
compatible. There is one sensor/actuator per mes- Master/slave access principle
sage bit. A higher-level master polls the slaves in sequence (i.e.
in accordance with their addresses). Each slave ad-
APM dressed responds with its data.
Alternating pulse modulation. Representation of the
bits on the AS-Interface cable. Each bit corresponds to Parameter bits
one sin² pulse. Each positive pulse is followed by a These specify how the individual parameters of a
negative pulse, and vice versa. Extremely resistant slave are set. For example, open/close, absolute/rela-
against noise. tive distance in US sensors, bright/dark switching for
photoelectric sensors. They can be modified if re-
AS-Interface specification quired.
According to Specification 2.04, a maximum of 31 bi-
nary I/O modules can be connected. Specification Parity check
2.11 states that up to 62 binary modules can be con- Simple error check. On AS-Interface, the sum of the
nected. These are denoted as A/B slaves. Profile 7.3 user bits within a message (address, data, control bits,
defined in Specification 2.11 permits the connection parity bit) must be even. The parity bit is selected by
and data transfer of up to 31 analogue modules. the transmitter.
Bit error rate (BER) Project data
Specifies the average number of transmission errors. Setpoint status of an AS-Interface network. The con-
figuration data of all slaves (I/O, ID) is stored in non-
Operational current volatile memory in the master (list of projected slaves,
Current Ie, required by the device for correct operation. LPS).
The AS-Interface current consumption on modules is
calculated by adding together the operational current By comparing the setpoint and actual configuration,
and the output current Iout. the master can detect slaves that have been connect-
ed incorrectly or are missing.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Data integrity
In accordance with DIN 19244, a measure for data Residual error probability
transfer error protection. The lowest data integrity Specifies the average number of transmission errors
class is I1, the highest is I3. that remain once all error detection strategies have
been applied.
I/O configuration
For four-way I/O modules for example, specifies which
of the 4 data bits of the message are inputs and which
are outputs. Cannot be modified.

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
346 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - Additional Information
Sensor Additional information:
A device which detects and relays a status or a meas- AS-Interface - The Solution for Automation
ured quantity, e.g. sensors for distance measurement A Compendium of Technology, Function, and Applica-
(inductive, capacitive, photoelectric, ultrasonic, etc.). tions
© 2002 AS-International Association
Safety category (as defined in EN 954-1)
Classification of safety-related components with re-
spect to their resistance to error and behavior in case
of error, which is achieved based on the structural ar-
rangement of parts and/or their reliability.
Slave
Passive participant on the bus. It will only respond
when addressed. Slaves are identified by their ad-
dresses. The factory setting for AS-Interface slaves is
address 0.
Message
A message sent by the master, or a message sent in
reply by a slave.
Transfer rate
Transfer speed of the bits on the bus line. Measured in AS-Interface - Safety at Work
bit/s = Baud (Bd). Fail-Safe Technology in Automation
Introduction and Application Examples
Cycle time
© 2003 AS-International Association
Period of time until an addressed slave is addressed
again. The cycle time is more significant than the
transfer rate. The fewer slaves there are, the shorter
the cycle time.
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 347
AS-Interface - type codes
12.2 AS-Interface type codes (without modules and accessories)

VAG - PB - K5 - R4 - DM

Further extensions
D Master with graphical display
DM Dual master
DMD Dual master with graphical display
CTR Gateway with control function
EFD Ground fault detection
DN Dual power supply
PE Power Extender
SIM Simulator

Master/gateway interface type


R2 RS 232
R3 RS 422
R4 RS 485
PCI PCI interface for PC

Housing type
KE Terminal housing (22 mm wide, 105 mm high)
KE1 Terminal housing (22 mm wide, 50 mm high)
KE2 Terminal housing (22 mm wide, 90 mm high)
KF Terminal housing Power Rail
K5 Terminal housing Gateway
K6 Terminal housing (3 A power supply, 50 mm wide)
K7 Terminal housing (2x4 A power supply, 120 mm wide)
K8 Terminal housing (2.8 A power supply, 140 mm wide)
K13 Terminal housing (2.4 A power supply, 60 mm wide)
K14 Terminal housing (4.8 A power supply, 113 mm wide)
K16 Terminal housing (8 A power supply, 91 mm wide)
K17 Terminal housing (4 A power supply, 70 mm wide)
K20 Terminal housing Gateway
G4 G4 housing
G4F G4 housing with base for flat cable

Master/gateway interface
PB Profibus
MOD Modbus
MOD+ Modbus-Plus
CCL CC-Link
CAN CANopen
DN DeviceNet
IBS Interbus-S
IP Ethernet TCP/IP
CTR Master with control function (integrated PLC functionality)

Further functions
SW Software
HH Handheld

Product group
M Master
G Gateway
N Power pack
R Repeater
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

E Extender
S Safety monitor
A I/O module / analogue module
P Programming unit
Z Accessories

AS-Interface specification
VA Product designed to AS-Interface specification 2.04
VB Product designed to AS-Interface specification 2.11
U Base for module

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
348 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
AS-Interface - type codes
12.3 Type code for I/O modules / analogue modules

VAA - 2EA - G2 - ZE/E2 -

Extensions
Ex Device certified for use in hazardous areas
DK Data coupler for two AS-Interface circuits

Input/output type
Z Input for 2-wire sensors, PNP, DC
ZA Input for 2 or 3-wire sensors, PNP, DC, two inputs on sockets 1 and 3
ZA0 Input for 2 or 3-wire sensors, NPN, DC, two inputs on sockets 1 and 3
ZA0/EA0 Input for 2 or 3-wire sensors, NPN, DC, two inputs on sockets 1 and 3/
transistor output, NPN, two outputs on sockets 1 and 3
ZA/EA2 Input for 2 or 3-wire sensors, PNP, DC, two inputs on sockets 1 and 3/
transistor output, PNP, DC, two outputs on sockets 1 and 3
ZE Input for 2 or 3-wire sensors, PNP, DC
ZE/E2 Input for 2 or 3-wire sensors, PNP, DC/transistor output PNP
ZE0 Input for 2 or 3-wire sensors, NPN, DC
ZE0/E0 Input for 2 or 3-wire sensors, NPN, DC/transistor output, NPN
ZE/P-S Input for 2 or 3-wire sensors, PNP, DC/pneumatic output
ZE/R Input for 2 or 3-wire sensors, PNP, DC/relay output
ZE/T Input for 2 or 3-wire sensors, PNP, DC/triac output
EA0 Transistor output, NPN, two outputs on sockets 1 and 3
E2 Transistor output, PNP
E0 Transistor output, NPN
N Input for NAMUR sensors
N/V2 Input for NAMUR sensors/output for valve control
R Relay output
SN Input for safety sensors
WS Input for 2 or 3-wire sensors, AC
WS/R Input for 2 or 3-wire sensors, AC/relay output
WS/T Input for 2 or 3-wire sensors, AC/triac output
I Input or output analogue current
U Input or output analogue voltage

Housing type
CB Circuit board, board with solder connection
CB1 Circuit board, board with solder connection
G1 G1 standard module
G2 G2 flat module
G4 G4 module
G5 G5 Ex module
G6 G6 compact module
KF Terminal housing, removable terminals, power rail
KF2 Terminal housing, removable terminals, power rail, 3 terminal blocks
KE Terminal housing (22 mm wide, 105 mm high)
KE1 Terminal housing (22 mm wide, 50 mm high)
KE2 Terminal housing (22 mm wide, 92 mm high)
K3 Terminal housing (71 mm wide)
F85 Emergency shutoff switch
F86 Illuminated pushbutton

Number of inputs/outputs
4EA 4 inputs and 4 outputs
4E3A 4 inputs and 3 outputs
4E2A 4 inputs and 2 outputs
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

2E2A 2 inputs and 2 outputs


2EA 2 inputs and 2 outputs
1E3A 1 input and 3 outputs
2*EA 2 inputs and 2 outputs, 2 sockets with commonly assigned inputs and outputs
2E 2 inputs
2A 2 outputs
4E 4 inputs
4A 4 outputs
etc. etc.

Module type
Standard module in accordance with AS-Interface Specification 2.04
VAA
A/B I/O module in accordance with AS-Interface Specification 2.11 or analogue module in
VBA
accordance with Profile 7.3

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 349
AS-Interface - type codes
12.4 Type code for cable sockets
V1-W-E2/E3-2M-PVC – Cable materi- – PVC
al – PUR
– PUR H/S, halogen-free, radiation-crosslinked
– PUR S/PE, radiation-crosslinked, with PE

–2m
– Cable length –5m
– other lengths on request

– E2 (for 3-wire PNP)


– LED – E0 (for 3-wire NPN)
– E2/E3 (contact 2 + 4 jumpers)
– A0 (2 LED for 4-wire NPN)
– A2 (2 LED for 4-wire PNP)
– No code = without LED

–W angled
– Design –G straight
– WM angled, cap nut
– WR angled, ratchet lock
– GR straight, ratchet lock

– V1 M12 x 1, 4-pin, DC
– Connection – V1S M12 x 1, 4-pin, DC, connector
type – V13 M12 x 1, 3-pin, AC
– V15 M12 x 1, 5-pin, DC
– V3 M8 x 1, 3-pin, DC
– V3S M8 x 1, 3-pin, DC, connector
– V16 Rd24 x 1/8, 7-pin, AC/DC
– V18 M18 x 1, 4-pin, AC/DC
– V31 M8 x 1, 4-pin, DC
– V31S M8 x 1, 4-pin, DC, connector
–V with central screw, 4-pin

12.5 Type codes for connector cables


V1-G-5M-PUR-V1-G – straight

– V1 connector M12 x 1, 4-pin, DC Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
350 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Notes
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 351
Pepperl+Fuchs GmbH worldwide
12.6 Pepperl+Fuchs GmbH worldwide
Croatia Germany
Zentrale weltweit El-Pro d.o.o. Pepperl+Fuchs Drehgeber GmbH
Worldwide Head Office (Distributor FA + PA) Föhrenstraße 33
Pepperl+Fuchs GmbH Fallerovo Setaliste 22 78532 Tuttlingen
Königsberger Allee 87 10000 Zagreb Telephone +49 7461 9298-0
68307 Mannheim Telephone +385 1 3667428 Telefax +49 7461 9298-22
Telephone +49 621 776-0 Telefax +385 1 3667428
Telefax +49 621 776-1000 el-pro@zg.tel.hr Visolux, Zweigniederlassung
info@de.pepperl-fuchs.com der Pepperl+Fuchs GmbH
Czech Republic Prinzenstraße 85
FCC PRUMYSLOVE SYSTEMY 10969 BERLIN
S.R.O. Telephone +49 30 61672-0
SNP 8 Telefax +49 30 61672-468
400 11 USTI NAD LABEM
Telephone +420 47 2774173 Great Britain
Telefax +420 47 2772115 Pepperl+Fuchs (GB) Ltd.
usti@fccps.cz 77 Ripponden Road
OLDHAM OL1 4EL, Lancashire
FCC PRUMYSLOVE SYSTEMY Telephone +44 161 6336431
S.R.O. Telefax +44 161 6246537
U Slovanky 3 sales@gb.pepperl-fuchs.com
182 00 PRAHA 8
Telephone +420 2 66052099 Greece
Telefax +420 2 86890252 Uteco A.B.E.E.
info@fccps.cz 16 Mavrogenous Street
Austria 185 42 PIRAEUS
Pepperl+Fuchs Ges.m.b.H. FCC PRUMYSLOVE SYSTEMY Telephone +30 210 4210050
Industriestraße B 13 S.R.O. Telefax +30 210 4212033
2345 BRUNN/GEB. Vinarská 3 uteco@uteco.gr
Telephone +43 2236 33441 603 00 BRNO
Telefax +43 2236 31682 Telephone +420 5 43215654 Hungary
info@at.pepperl-fuchs.com Telefax +420 5 43215655 Pepperl+Fuchs Kft.
brno@fccps.cz (FA)
Bahrain Kisto Utca 16-18
Texas Technical Services Denmark 8200 VESZPREM
P.O. Box: 11302 Pepperl+Fuchs A/S Telephone +36 88 590100
Manama Stamholmen 173 Telefax +36 88 590132
Telephone +973 789555 2650 HVIDOVRE kmikola@hu.pepperl-fuchs.com
Telefax +973 789666 Telephone +45 70104210
textech@batelco.com.bh Telefax +45 70104211 Iceland
Tölvusalan ehf.
Baltic States Egypt Suourlandsbraut 20
ELEKOMS Ltd. Pepperl+Fuchs Egypt (LLC) P.O. Box 8960
Turaidas Str. 10 9 Abd Al Hamied Lotfy Street, Zone 8 128 REYKJAVIK
LV-1039 RIGA, Latvija Nasr City Telephone +354 5 500450
Telephone +371 7336444 Telephone +20 2 2721097 Telephone +354 5 500454
Telefax +371 7336448 Telefax +20 2 2756096 Telefax +354 5 500402
elekoms@apollo.lv mesmat@pepperl-fuchs.com.eg agusta@islandia.is

Belgium Finland Iran


Pepperl+Fuchs N.V./S.A. SensoNor Oy Asan Sazan Farayand
Metropoolstraat 11 Kartanontie 20 (PA + FA Representation)
2900 SCHOTEN 00330 HELSINKI Unit No. 17, No. 7, Taghavi St.
Date of issue 2004-19-11 – Catalogue AS-Interface 2004/2005

Telephone +32 3 6442500 Telephone +358 9 4777200 Soherevardi Shomali Ave.


Telefax +32 3 6442441 Telefax +358 9 47772020 15686 TEHRAN
sales@be.pepperl-fuchs.com joel.patrikka@sensonor.fi Telephone +98 21 8440915
Telefax +98 21 8440915
Bulgaria France n_atai@dpimail.net
Process Control Pepperl+Fuchs SARL
(PA Representation) 12 Avenue des Tropiques Ireland
Tzarichina Str. 1 91955 COURTABOEUF CEDEX Insteco Ltd.
1505 SOFIA Telephone +33 1 60921313 The Coach House
Telephone +359 2 703549 Telefax +33 1 60921325 Slane
Telefax +359 2 703549 commercial@fr.pepperl-fuchs.com Co Meath
processcontrol@bulmail.net Telephone +353 41 9884288
Telefax +353 41 9884292

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
352 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Pepperl+Fuchs GmbH worldwide

Israel Nigeria Portugal


Kama Ltd. Equipment & Controls Nigeria Ltd. Pepperl+Fuchs, S.A.
20 Hametsuda St. Plot 181 Kofo Abayomi Street, Txorri-Erri Etorbidea, 46 Pol. Izarza
58 190 AZOR No. 3 C E-48150 SONDIKA
Telephone +972 3 5567747 Victoria Islands, LAGOS (responsible for Portugal)
Telefax +972 3 5567548 Telephone +234 1 2615023 Telephone +349 4 4535020
Kama@netvision.net.il Telefax +234 1 2615169 Telefax +349 4 4535180
sanjeev@linkserve.com.ng sov@es.pepperl-fuchs.com
MAYSAF N. H. Ltd.
(FA Representation) Norway Qatar
Electrical & Control Systems Elteco A/S Doha Petroleum Construction
Mirza Kadesh 5 Postboks 96 FA + PA Representative)
P.O. Box 85 Floodmyrveien 24 Co. Ltd. (DOPET)
26272 KIRIAT HAIM N-3900 PORSGRUNN P.O. Box: 1744
Telephone +972 4 8409002 Telephone +47 35 573800 Doha
Telefax +972 4 8409001 Telefax +47 35 573849 Telephone +974 4600350
maysaf@netvision.net.il firmapost@elteco.no Telefax +974 4606347
bhargav@dopet.com
Italy Oman
Pepperl+Fuchs ELCON srl Riyam Engineering & Services L.L.C. Russia
Via delle Industrie, 4 (FA + PA Representative) INTERF L.L.C.
20050 MEZZAGO (Milano) P.O. Box: 1931 Office 1404, 18, str.1
Telephone +39 039 62921 112 Ruwi Vadkovskiy per.
Telefax +39 039 6292240 Telephone +968 594960 103055 MOSCOW
info@it.pepperl-fuchs.com Telefax +968 595536 Telephone +7 095 9732072
res@omzest.com Telefax +7 095 9783934
Kenia
Shankan Enterprises Ltd. Pakistan Prosoft Ltd.
P. O. Box 44432 Techno-Commercial (FA Representation)
NAIROBI Engineers-Representatives 108 Profsoyznaya Str.
Telephone +254 2 440093 18-24, Farid Plaza/65-Shadman 65 117437 MOSCOW
Telefax +254 2 441820 G.P.O. Box 937 Telephone +7 095 2340636
dks@kenyaonline.com 54000 LAHORE Telefax +7 095 2340640
Telephone +92 42 7584390 victor@prosoft.ru
Kuwait Telefax +92 42 7581771
Almeer Technical eswaat@brain.net.pk Saudi Arabia
Services Co. W.L.L. GAS Arabian Services Est.
P.O. Box: 9240 Tariq Electric House Representative (FA + PA)
61003 AHMDAI 1, Wahab Arcade, Near Denso Hall P.O. Box: 10487
Kuwait M. A. Jinnah Road 31961 Al-Jubail
Telephone +965 3986594 74200 KARACHI Telephone +966 3 3472696
Telefax +965 3980682 Telephone +92 21 2628409 Telefax +966 3 3473480
talal@almeer.com Telefax +92 21 2624460
teh@super.net.pk Slovakia
Netherlands FCC Priemyselne systemy s.r.o
Pepperl+Fuchs B.V. Poland Na uvrati 25
Het Wielsem 10 INTEX Sp.zo.o. 821 04 Bratislava
5231 BW‘s-HERTOGENBOSCH ul. W. Pola 16 Telephone +421 243 191751
Telephone +31 73 6409388 44-100 GLIWICE Telefax +421 243 141951
Telefax +31 73 6444749 Telephone +48 32 2307516
sales@nl.pepperl-fuchs.com Telefax +48 32 2307517 South Africa
intex@intex.com.pl P & F Products cc
P.O. Box 2809; 60, Fourth Ave.
Date of issue 2004-19-11 – Catalogue AS-Interface 2004/2005

EDENVALE 1610
Telephone +27 11 6098188
Telefax +27 11 4522026
pandf@pandf.co.za

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 353
Pepperl+Fuchs GmbH worldwide

Spain Turkey United Arab Emirates


Pepperl+Fuchs, S.A. Onur Mühendislik ve Otomasyon Pepperl+Fuchs (M.E.) FZE
Head Office San. Tic. Ltd. Sti. P.O. Box 61398
Txori-Erri Etorbidea, 46 Emek mah. Yildirim Sk. No. 23 Jebel Ali Free Zone
Pol. Izarza 81570 KUCUKYALI, ISTANBUL DUBAI
48150 SONDIKA (Vizcaya) Telephone +90 216 3889590 Telephone +971 4 8817016
Telephone +349 4 4535020 Telefax +90 216 4896020 Telefax +971 4 8816935
Telefax +349 4 4535180 info@onurmuh.com.tr info@ae.pepperl-fuchs.com
sov@es.pepperl-fuchs.com
Net Mühendislik ve Otomasyon United Eastern Group
Sweden (FA Presentation only photoelectric) Representatative (FA + PA)
Pepperl+Fuchs AB San. Tic. Ltd. Sti. P.O. Box 7615
Bultgatan 40 b Perpa Ticaret Merkezi A Blok Abu Dhabi
442 40 KUNGÄLV kat: 5 No:174/176 Telephone +971 2 6272737
Telephone +46 303 246070 OKMEYDAMI, ISTANBUL Telefax +971 2 6270048
Telefax +46 303 246089 Telephone +90 212 2109354 kanone@ueg.co.ae
info@se.pepperl-fuchs.com Telefax +90 212 2109359
info@netmuh.com.tr Nils & Abbas Trading Co. L. L. C.
Switzerland P. O. Box 26564
Pepperl+Fuchs AG DUBAI
Sägeweg 7 Telephone +971 4 3390044
2557 STUDEN BE Telefax +971 4 3388732
Telephone +41 32 3747676 jens@nilsabbas.com
Telefax +41 32 3747678
info@ch.pepperl-fuchs.com

Date of issue 2004-19-11 – Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
354 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Pepperl+Fuchs GmbH worldwide

Brazil Ecuador
Zentrale USA Pepperl+Fuchs Ltda. Alfatecnica S.A.
USA Head Office Avenida Kennedy, 164-4° Andar Cll 93 No. 19-75
Pepperl+Fuchs Inc. Jardim do Mar SANTAFE DE BOGOTA D.C.
1600 Enterprise Parkway CEP 09726-250 Colombia
TWINSBURG OHIO, 44087 SAO BERNARDO DO CAMPO Telephone +57 1 5300808
Telephone +1 330 4253555 Telephone +55 11 41223233 Telefax +57 1 538388
Telefax +1 330 4254607 Telefax +55 11 41257329 sales@us.pepperl-fuchs.com
sales@us.pepperl-fuchs.com vendas@br.pepperl-fuchs.com
Guatemala
Canada PROYECT Asesoria Industrial
Pepperl+Fuchs Inc. 8a. Avenida 33-10,
1600 Enterprise Parkway Zona 11 - Las Charcas
Twinsburg, OHIO 44087 CD. de GUATEMALA
USA Telephone +502 4 7674 33 to 38
Telephone +1 330 4253555 Telefax +502 4 767439
Telefax +1 330 4254607 guatemala@grupoproyect.com
sales@us.pepperl-fuchs.com
Mexiko
Chile Pepperl+Fuchs México, S.A. de C.V.
Desimat Ingenieria Ltda. (Head Quarter)
(FA Representation) Blvd. Xola 613, P.H.
Rut.: 78.131.420-K Col. Del Valle
Av. Puerto Vespucio 9670 03100 MEXICO D.F.
Loteo Industrial Puerto Santiago Telephone +52 55 56391951
PUDAHUEL-SANTIAGO Telefax +52 55 56398865
Argentina Telephone +56 2 7470152 pfmexico@mpsnet.com.mx
Bruno Schillig S.A. Telefax +56 2 7470153
Arenales (Dip. Ortiz) 4030 importaciones@desimat.cl Venezuela
1602 Florida, BUENOS AIRES Pepperl+Fuchs, Inc.
Telephone +54 11 47301100 INECO Ltda. 1600 Enterprise Parkway
Telefax +54 11 47617244 Sociedad de Ingenieria TWINSBURG OHIO, 44087
schillig@schillig.com.ar Equipos y Control Industrial Limitada USA
Ejercito 16, Piso 4 Telephone +1 330 4253555
Bolivia 6510449 SANTIAGO DE CHILE Telefax +1 330 4254607
Hiller Electric SA Telephone +56 2 4638600 sales@us.pepperl-fuchs.com
Av. El Trompillo 573 Telefax +56 2 4411023
Casilla 370
SANTA CRUZ Colombia
Telephone +591 3 3524484 Alfatecnica S.A.
Telefax +591 3 3526404 Control de Procesos y
mail@hillerelectric.com.bo Automatizacion Ind
Avenida El Dorado No. 98 - 51
Oficina 306 A
SANTAFE DE BOGOTA
Telephone +57 1 4154077
Telefax +57 1 2987460
importaciones@alfatecnica.com.co
Date of issue 2004-19-11 – Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 355
Pepperl+Fuchs GmbH worldwide

Pepperl+Fuchs Guangzhou Office Pepperl+Fuchs (India) Pvt. Ltd.


Zentrale Asien (PA & FA Office) (Pune Area Sales Office)
Asia Pacific Head Office Room G Building 13, Jiayiyuan, Roof & Services, Ground Floor
Pepperl+Fuchs PTE Ltd. Tianhei Bei Road Tianhe District Veer Savarkar Udyog Bhavan
P+F Building 510062 GUANGZHOU Shivaji Nagar,
18 Ayer Rajah Crescent Telephone +86 20 38805159 PUNE - 411005
SINGAPORE 139942 Telefax +86 20 38808505 Telephone +91 20 25538658
Telephone +65 67799091 pfgzoo@public.guangzhou.gd.cn Telefax +91 20 25538757
Telefax +65 68731637 pune@in.pepperl-fuchs.com
sales@sg.pepperl-fuchs.com Hong Kong
Foober (Hong Kong) Co., Ltd. Pepperl+Fuchs (India) Pvt. Ltd.
(FA and PA Representation) (Regional Sales Office - West)
Room 1208 Shui On Centre No.401, A-Wing, Subham Centre-1,
6-8 Harbour Road 4th floor
WANCHAI, Hong Kong Cardinal Gracias Road, Chakala
Telephone +852 25283558 Andheri (East)
Telefax +852 25289371 MUMBAI - 400 099
fooberhk@netvigator.com Telephone +91 22 28231946
Telefax +91 22 28231947
ERA International Investment wro@in.pepperl-fuchs.com
Development
(FA Representation) Pepperl+Fuchs (India) Pvt. Ltd.
Room 1218, 12/F, Blk 2, Nam Fung (Vadodara Area Sales Office)
Ind. City UG28 Upper Ground Floor
18 Tin Hau Road, Tuen Mun "Concorde" R.C. Dutt Road
N. T. Hong Kong Opp Alkapuri Petrol Pump,
Telephone +852 81010385 Alkapuri Vadodara
Telefax +852 23224440 GUJARAT - 390 005
Australia
T001@netvigator.com Telephone +91 265 5522516
Pepperl+Fuchs Australia Pty Ltd.
Telefax +91 265 5522516
Unit 7/72-74 Chifley Drive
India
PRESTON, VICTORIA 3072
Pepperl+Fuchs (India) Pvt. Ltd. Pepperl+Fuchs India Pvt. Ltd.
Telephone +61 3 94958600
(Head Office) (Hyderabad Area Office)
Telefax +61 3 94846366
Plot No. 10, 3rd Main, 1st Stage Hi Tech Business Centre,
pfa@au.pepperl-fuchs.com
Peenya Industrial Estate 4th Floor, Topaz Bldg.
BANGALORE - 560 058 Amrutha Hills, Punjagutta
China
Telephone +91 80 28378030 HYDERABAD - 500 082
Pepperl+Fuchs Shanghai
Telefax +91 80 28378031 Telephone +91 40 23407053
(FA Head Office)
info@in.pepperl-fuchs.com hyderabad@in.pepperl-fuchs.com
No. 9, Lane 163 Tan Jia Qiao Road
SHANGHAI, 200070
Pepperl+Fuchs (India) Pvt. Ltd. Pepperl + Fuchs (India) Pvt. Ltd.
Telephone +86 21 56525989
(Regional Sales Office - North) (Regional Sales Office - South)
Telefax +86 21 56527164
305, Ansal Chamber II (Tamilnadu & Kerala)
info@cn.pepperl-fuchs.com
6, Bhikaji Cama Place No. 4, First Floor, X 70,
NEW DELHI - 110 066 Sindur Shopping Complex,
Pepperl+Fuchs Beijing Rep. Office
Telephone +91 11 26170207 2nd Avenue, Anna Nagar
(PA Head Office)
Telefax +91 11 26166291 CHENNAI - 600 040
Prime Tower, Room 2007
nro@in.pepperl-fuchs.com Telephone +91 44 26190129
No. 22 ChaoYangMenWai Street
Telefax +91 44 26190129
BEIJING 100020
Pepperl+Fuchs (India) Pvt. Ltd. chennai@in.pepperl-fuchs.com
Telephone +86 10 65885143
(Regional Sales Office - East)
Telefax +86 10 65885144
Room No. 221, II Floor "LORDS" Pepperl + Fuchs (India) Pvt. Ltd.
pfbj@95777.com
7/1, Lord Sinha Road (Coimbatore Area Office)
Date of issue 2004-19-11 – Catalogue AS-Interface 2004/2005

KOLKATA - 700 071 43A, 1st Floor


Pepperl+Fuchs Pte. Ltd.
Telephone +91 33 22828539 7th Street, K. K. Pudur
Shanghai Representative Office
Telefax +91 33 22828777 COIMBATORE-38
(PA Rep. Office)
ero@in.pepperl-fuchs.com Telefax +91 422 2450727
218 Tainmu West Road,
Kerry Everbright City Tower 1,
Pepperl+Fuchs (India) Pvt. Ltd. Indonesia
Room 2509
(Regional Sales Office - South) PT Himalaya Everest Jaya
200070 SHANGHAI
(Karnataka & Andhra Pradesh) (FA Representation)
Telephone +86 21 63542910
C-328, 3rd Main, 1st Stage, Jln. Daan Mogot Km. 10, No. 151
Telefax +86 21 63546536
Peenya Industrial Estate Pesing Poglar
pfshapa@public8.sta.net.cn
BANGALORE - 560 058 JAKARTA Barat 11710
Telephone +91 80 28371225 Telephone +62 21 5448956
Telefax +91 80 28378031 Telefax +62 21 6194658
sales@in.pepperl-fuchs.com himalaya@indosat.net.id

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
356 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Pepperl+Fuchs GmbH worldwide

PT Pepperl and Fuchs Bintan New Zealand Globe Royal Cavalier Corp.
SD 56, 57 Lobam Unilink Automation Ltd. (PA Representation)
Bintan Industrial Estate (FA Representation) 6th Floor, 23 Jen Ai Road, Sec. 3
PULAU BINTAN, RIAU PO Box 300785, Albany TAIPEI 106
Telephone +62 770 696675 10E Vega Place, Mairangi Bay Telephone +886 2 27718246
Telefax +62 770 696677 1130 AUCKLAND Telefax +886 2 27519032
Telephone +64 9 4760286 grcc@ms19.hinet.net
PT Binakarya Sentosaprima Telefax +64 9 4760267
(PA Representation) sales@unilink.co.nz Thailand
Citra Garden 1 Blok C-2/24 Industrial Electrical Co., Ltd.
11840 JAKARTA Custom Control Ltd. (FA Representation)
Telephone +62 21 5451136 (PA Representation) 85/3 Soi Sot Phin San
Telephone +62 21 5451137 16 Mahunga Drive, Mangere Bridge Rang Nam Road, Rajthevee
Telefax +61 21 5403647 Private Bag Rajthevee, BANGKOK 10400
ptbina@cbn.net.id 92 902 ONEHUNGA, AUCKLAND 6 Telephone +66 2 6427887
Telephone +64 9 6341391 Telefax +66 2 6424249
Japan Telefax +64 9 6365976 iecl@ie.co.th
Pepperl+Fuchs K.K. jneville@customcontrols.co.nz
German Industry Center 401 Delta Elmech Co., Ltd.
18-2 Hakusan 1-Chome, Midori-Ku Philippines (PA Representation)
YOKOHAMA 226-0006 Jaylan Mill Trades Inc. 76 Pattanakarn Soi 53
Telephone +81 45 9397802 (FA Representation) (Muangthong 2/3)
Telefax +81 45 9397804 #109 E. Rodriguez Jr. Avenue Pattanakarn Road, Suanluang
sales@jp.pepperl-fuchs.com Paranaque City 1700 BANGKOK 10250
Telephone +63 2 8223182 Telephone +66 2 3225423
Korea Telefax +63 2 8219100 Telephone +66 2 3225430
Pepperl+Fuchs Korea Ltd. jlanmill@info.com.ph Telefax +66 2 3221762
Bum-Yang Bang-Bae Bldg. deltabkk@deltaelmech.co.th
5th Floor, #811-6, Bang Bae-dong Multiplex Instrumentation & Control
Seo Cho-Ku Equipment Services Vietnam
137060 SEOUL (PA Representation) Thien Luan
Telephone +82 2 34819494 3378 A Lbarra Street Trading & Services Co. Ltd.
Telefax +82 2 34819495 PALANAN MAKATI CITY (PA Representation)
info@kr.pepperl-fuchs.com Telephone +63 2 5501473 i41-i42 Tay Thanh Street,
Telefax +63 2 5501475 Tan Binh Industrial Park
Malaysia edgavinol@lycos.com Ward 15, Tan Binh District
Industrial Automation (M) SDN BHD HO CHIH MINH CITY
(Kuala Lumpur Office FA) Taiwan Telephone +84 (8) 8150136
30-3 & 30-4, Jalan Loke Yew Kawa Kami Enterprise Corp. Telefax +84 (8) 8150137
55200 KUALA LUMPUR (FA Representation) thienluan@hcm.vnn.vn
Telephone +60 3 92210511 1F, No. 41, Lane 76,
Telefax +60 3 92222299 Jui Kuang Road, Neihu District Provina Technology Co. Ltd.
sales.kl@iasb.com.my 114 TAIPEI (FA Representation)
Telephone +886 2 27920078 148B Nam Ky Khoi Nghia
Miran Engineering Sdn Bhd Telefax +886 2 87917969 Q1 TP HO CHI MINH CITY
(PA Representation) kawa.kami@msa.hinet.net Telephone +84 (8) 8298901
No. 16 Jalan Astaka U8/82 Telefax +84 (8) 8295486
Bukit Jelutong Commercial Area provina@hcm.vnn.cn
40150 SHAH ALAM SELANGOR
Telephone +60 3 78473278
Telefax +60 3 78475236
zainuddin@trisys.com.my
Date of issue 2004-19-11 – Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 357
13 ALPHABETICAL LIST OF TYPES

Alphabetical list of types


Type Page Type Page
BSM58 297 V3-... cable sockets 339
BSS58 281 V31-... cable sockets 339
BVE14 287 V31S-... cable connector 342
BVM14 303 V3S-... cable connector 342
BVM58 291 VAA-1E3A-M18-ZE/E2-V1 234
BVS58 275 VAA-2*EA-G2-ZE/E2 164
LD28/LV28-LAS-F1-B3B/73c 264 VAA-2E2A-G2-S/EA2 96
NBB20+U1+B3B 247 VAA-2E2A-KE1-S/E2 100
NBB20-L2-B3B-V1 244 VAA-2EA-G2-ZE/E2 162
NBB40-FP-B3B-P1 250 VAA-2EA-G4-ZE/E2 178
NBB50-FP-B3B-P1 251 VAA-2EA-G6-ZE/E2 186
NBB6-F-B3 243 VAA-2E-F85-V1 104
NBN30+U1+B3B 248 VAA-2E-G2-S 98
NBN30-L2-B3B-V1 245 VAA-2E-G4-SN 94
NBN40+U1+B3B 249 VAA-2E-KE1-S 102
NBN40-L2-B3B-V1 246 VAA-4A-G2-E2 168
NBN50-FP-B3B-P1 251 VAA-4A-G5-V2-Ex 212
NCB10-30GM70-B3-V1 242 VAA-4A-G6-E2 190
NCB4-12GM60-B3B-V1 238 VAA-4A-K3-R 148
NCB5-18GM60-B3B-V1 240 VAA-4A-KF-E2 116
NCN15-30GM70-B3-V1 242 VAA-4E2A-G1-ZE/P-S 218
NCN3-F31-B3B-V1-K 253 VAA-4E2A-G5-N/V2-Ex 208
NCN4-12GM60-B3B-C2-V1 239 VAA-4E4A-CB1-Z/E2 230
NCN8-18GM60-B3B-V1 241 VAA-4E4A-KE-ZE/E2 136
OCS3000-M1A-B3 270 VAA-4E4A-KE-ZE/R 138
OCS3000-M1A-B3-V1 270 VAA-4EA-CB-E/E2-S 226
OCT500-M1A-B3 266 VAA-4EA-G2-ZE/E2 160
OCT500-M1A-B3-V1 266 VAA-4EA-G4-ZE/E2 176
PL1-F25-B3-K 252 VAA-4EA-G6-ZE/E2 184
PR-05 334 VAA-4EA-K3-ZE/E2 146
RL28-55-B3B/73c 256 VAA-4EA-KF2-ZE/E2 120
RL28-55-LAS-B3B/73c 260 VAA-4EA-KF2-ZE/R 122
RL28-55-V-B3B/73c 258 VAA-4EA-KF2-ZE/T 124
RL28-8-H-400-RT-B3B/73c 262 VAA-4EA-KF-DK 118
RL28-8-H-700-RT-B3B/73c 262 VAA-4EA-KF-ZE/E2 110
U-G1F 314 VAA-4EA-KF-ZE/R 112
U-G1FA 315 VAA-4E-G2-ZE 166
U-G1FF 316 VAA-4E-G4-N 182
U-G1FFA 317 VAA-4E-G4-Z 180
U-G1P 318 VAA-4E-G6-ZE 188
U-G1PP 319 VAA-4E-KF2-ZE 126
U-G2FF 320 VAA-4E-KF-ZE 114
U-G3FF 321 VAA-LT2-G1 222
UPR-05 335 VAA-LT3-F86-V1 224
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

V... screw terminal connectors 337 VAG-IBS-KF-FB 42


V1-... cable sockets 339 VAG-MOD-KF-R4 46
V1-... connection cable 343 VAG-PB-G4F-R4 40
V11-... cable sockets 340 VAN-115/230AC-K13-EFD 62
V11-... connection cable 343 VAN-115/230AC-K14-EFD 64
V13-... cable sockets 341 VAN-115/230AC-K16 66
V15-... cable sockets 340 VAN-115/230AC-K17 60
V15S-T-V15 337 VAN-115/230AC-K7-DN 68
V16-... cable sockets 341 VAN-115/230AC-K8 70
V1S-... cable connector 342 VAN-24DC-K6 72
V1S-T-V1 337 VAN-G4-PE 74

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
358 Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Alphabetical list of types
Type Page Type Page
VAR-G4F 76 VBA-4E2A-KE1-Z/E2 142
VAR-KE2 78 VBA-4E3A-CB-E/E2-P 228
VAS-1A-K12 88 VBA-4E3A-CB-E/E2-S 232
VAS-1A-K12-U 86 VBA-4E3A-G2-ZA/EA2 152
VAS-2A-K12 92 VBA-4E3A-G4-ZE/E2 170
VAS-2A-K12-U 90 VBA-4E3A-KE-ZE/E2 128
VAZ-2FK-B1 328 VBA-4E3A-KE-ZE/R 130
VAZ-2T1-FK-*M-PUR-V1-W 324 VBA-4E-G2-ZA 158
VAZ-2T1-FK-2M-PUR-V1-G 324 VBA-4E-G4-Pt100 194
VAZ-2T5-G2 332 VBA-4E-G4-ZE 174
VAZ-DK-G1 322 VBA-4E-KE1-Z 144
VAZ-DN-SIM-USB 312 VBA-4E-KE-ZE 134
VAZ-FK-*-** 310 VBA-8E-G2-ZA 156
VAZ-FK-CL1 322 VBG-CAN-K5-D 52
VBG-CCL-G4F 54
VAZ-FK-ED-G2 322
VBG-DN-K5-D 48
VAZ-FK-R-STRIPPER 331
VBG-DN-K5-DMD 50
VAZ-FK-S-STRIPPER 331
VBG-IP-K5-DM 44
VAZ-FK-ST1 322
VBG-PB-G4F-R4 38
VAZ-G4-B 329 VBG-PB-K20-D 30
VAZ-G6F-V1 325 VBG-PB-K20-DMD 32
VAZ-G6F-W2M 325 VBG-PB-K5-R4-DMD 36
VAZ-PB-SIM 311 VBG-PB-KF-R4 34
VAZ-PG11-FKD 327 VBM-CTR-KF-R2 26
VAZ-PK-1,5M-V1-G 328 VBM-CTR-PCI-DM 28
VAZ-R4-R2 313 VBP-HH1 308
VAZ-SIMON-R2 330
VAZ-SIMON-RJ45 330
VAZ-SW-ACT32 330
VAZ-SW-SIMON 330
VAZ-T1-FK-*M-PUR-V1-G 323
VAZ-T1-FK-*M-PUR-V1-W 323
VAZ-T1-FK-CLAMP 328
VAZ-T1-FK-M20 327
VAZ-T1-FK-PG11 327
VAZ-T1-FK-PG9 327
VAZ-T1-FK-V1 326
VAZ-T1-FK-V1-DIG 326
VAZ-T1-FK-V1-V4A 326
VAZ-T1-FK-W-PG7 326
VAZ-T1-G2F 325
VAZ-TERM 331
VAZ-TUNER 331
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

VAZ-V1-B 329
VAZ-V1-B1 329
VAZ-V3-B 329
VBA-2A-G4-I 200
VBA-2A-G4-U 202
VBA-2E2A-G2-ZA/EA2 154
VBA-2E2A-G4-ZE/E2 172
VBA-2E-G4-I 196
VBA-2E-G4-U 198
VBA-2E-KE2-I/U 204

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 359
Notes

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany