0% found this document useful (0 votes)
127 views131 pages

Eletro Hidráulica Festo

This document provides information on standards-based valves according to ISO 5599-1. It describes key features of the valves such as being innovative, flexible, and reliable. Simple valve manifold assembly is explained with labeled diagrams. Various equipment options are listed such as different valve types and configurations that can be used. Valve manifold assembly with a vertical supply plate is also mentioned.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
127 views131 pages

Eletro Hidráulica Festo

This document provides information on standards-based valves according to ISO 5599-1. It describes key features of the valves such as being innovative, flexible, and reliable. Simple valve manifold assembly is explained with labeled diagrams. Various equipment options are listed such as different valve types and configurations that can be used. Valve manifold assembly with a vertical supply plate is also mentioned.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 131

Standards-based valves, to ISO 5599-1

e Festo Core Range With the Festo Core Range, we have selected
Solves the majority of your automation tasks the most important products and functions
from our broad product catalogue, and added Just look
the quickest delivery. for the
star!
Worldwide: Quickest delivery – wherever, whenever The Core Range offers you the best value
Simply good: Expected high Festo quality for your automation tasks.
Fast: Easy and fast to select
Standards-based valves to ISO 5599-1

Key features

Innovative Flexible Reliable Easy to install


• High-performance valves in a sturdy • Modular system offering a range of • Sturdy and durable ­metal compo- • Plug-in pressure gauges on the
metal housing configuration options nents pressure regulator plate
• Individual electrical connection via • Conversions and extensions are – Valves
square plug sockets or centrally for possible at any time – Horizontally linked sub-bases
each valve via round plug sockets • Integration of innovative ­function – Vertically stacked sub-bases
• Valve replacement under pressure modules possible • Fast troubleshooting thanks to LED
possible using vertical pressure – Pressure regulator plate in the plug socket or illuminating
shut-off plate – Throttle plate seal
• Reverse operation – Vertical pressure shut-off plate • LED integrated in the valve with the
• Vacuum operation – Vertical supply plate round plug variant
• Vertical supply plates permit a flexi- • Reliable servicing thanks to valves
ble air supply and variable pressure that can be replaced quickly and
zones easily
• Wide range of valve functions • Manual override
• Extensive operating voltage range • Durable thanks to tried-and-tested
from 12 V DC to 230 V AC piston spool valves

2 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Key features
Simple valve manifold assembly
[1] Pilot valve with port pattern to
ISO 15218
1 [2] Various voltages
[3] Armature tube for plug-on
10 2 solenoid coils
9 [4] End plate
3 [5] Manifold sub-base
8 [6] Various valve functions
[7] Cover plate for vacant/expansion
4 position
[8] Signal status display via LED
[9] 3-pin round plug
[10] Manual override
7
5

4
6

Equipment options
2x 2/2-way valve, single solenoid 2x 3/2-way valve, single solenoid 5/2-way valve 5/3-way valve
• Normally closed • Normally open • Single solenoid, mechanical or • Mid-position pressurised
• Normally closed, • Normally closed pneumatic spring return • Mid-position closed
vacuum operation possible • 1x normally open, 1x normally • Double solenoid • Mid-position exhausted
at port 3 and 5 closed • Double solenoid, with dominant
• Reverse operation possible signal at port 14
Operation with external pilot air Operation with internal pilot air Reverse operation with compressed Reverse operation with a pressure
supply supply air supply via ducts 3 and 5 regulator plate, compressed air
supply via duct 1
• For vacuum applications • For small pressure fluctuations in • Pressure zone separation via ducts • Reversible pressure regulator com-
• For working pressures lower than the power section 3 and 5 bined with a reversible 2x 3/2-way
3 bar • For using pressure regulator plates – Example: duct 3 vacuum, duct 5 valve regulates outputs 2 and 4
• For significant pressure fluctuations in a vertical stacking construction, ejector pulse – AB regulator for each of outputs 2
in the power unit. Power unit and also in reverse operation – Example: duct 3 high pressure for and 4
pneumatic control unit are isolated • As a low-cost solution advancing the piston rod of a – A regulator for output 4
• For heavily lubricated air in the double-acting cylinder. Duct 5 low – B regulator for output 2
power section pressure for retracting the piston • Reversible pressure regulators are
• For manifold assemblies where the rod with low energy consumption in the control position immediately
pressure zones are created via ducts • 2x 3/2-way valves used as 5/4-way after the power supply is switched
3 and 5 (not possible with 2x 3/2- valve with controllable overlap and on
way valves) pressure zone separation with the – Adjustment possible at all times
• For manifolds or pressure zones that reversible variant – Dynamic response characteristics
are equipped with reversible – Reduced regulator load because
2x 3/2-way valves (valves on the supply pressure is maintained
request) when the valve is switched
– Not exhausted via the regulator

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 3


Standards-based valves to ISO 5599-1

Key features
Valve manifold assembly with vertical stacking
[1] Solenoid valve with individual
1 pilot valves and port pattern to
ISO 15218, can be connected
using square plug sockets
[2] Solenoid valve with central round
plug
[3] Throttle plate for adjusting the
speed of the drive
[4] Vertical supply plate as separate
compressed air supply for a valve
[5] Vertical pressure shut-off plate for
2 replacing solenoid valves during
operation
3 [6] Pressure regulator for adjusting
the force of the actuated drive

Vertical stacking function


Pressure regulators Throttle plate Vertical pressure shut-off plate Vertical supply plate
• Single variant to regulate the pres- • Designed with two throttle valves, at • Equipped with a switch via which • As additional air supply for a valve
sure in duct 4 or 2 or 1 at the valve which the exhaust air flow rate at the compressed air supply can be • Separates the valve from duct 1 of
• Dual variant to regulate the pres- ducts 5 or 3 can be adjusted. shut off. As a result, components the manifold sub-base
sure in ducts 4 and 2 individually • The movement of the drive is initiat- mounted on the vertical pressure • To supply an additional pressure
• As reversible version with internally ed and the required speed is set via shut-off plate (e.g. a valve) can be zone
replaced ducts 1 and 3/5 the throttle plate using the manual replaced without switching off the
• With pressure gauge connection override on the valve. overall air supply.
• If the control chain has a redundant
connection, the cycle can continue
even in the case of a cyclical control
system.

Individual connection with square plug Individual connection with central round plug
The directional control valve has a pilot The electrical connection is estab-
control to ISO 15218. The solenoid coil lished via a standardised M12 plug,
plugged onto the armature tube can be 24 V DC (EN 61076-2-101).
chosen in different designs and oper-
ating voltages.

4 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Key features
Pressure regulator with one regulated duct Pressure regulator with 2 regulated ducts
• For pressure regulation at the sup- • For pressure regulation at working
ply input duct 1. The set pressure is ports 4 and 2
identical for ducts 2 and 4 • The pressure regulators for reverse
• For pressure regulation at working operation are supplied via duct 1 of
port 4 the manifold sub-base and supply
– The pressure regulator for reverse ducts 5 and 3 on the valve
operation is supplied via duct 1 of • The directional control valve is ex-
the manifold sub-base and sup- hausted via duct 1 to ducts 3 and 5
plies duct 5 on the valve of the manifold sub-base.
– The valve is exhausted via duct 1
to ducts 3 and 5 of the manifold
sub-base
• For pressure regulation at working
port 2
– In reverse operation duct 3 is
supplied here
Vertical supply plate Throttle plate
• As intermediate supply • Exhaust air flow control valves in
– For one valve ducts 3 and 5
– To supply an additional pressure • The throttle plates act as supply-air
zone flow control for pressure zones that
• Can be equipped with a valve are created via ducts 3 and 5
Vertical pressure shut-off plate Pressure gauge
A switch activated with a slotted screw- Plugs into the pressure regulators
driver shuts off duct 1:
• The throttle plates, pressure regula-
tors or valves positioned above it
can be replaced
• Other components of the control
chain such as drives, for example,
can be replaced once the valve has
been exhausted

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 5


Standards-based valves to ISO 5599-1

Key features
Port pattern on sub-base to ISO 5599-1

A B C D [A] Width 42 mm


[B] Width 52 mm
[C] Width 65 mm
14 [D] Width 76 mm
5

3
12

Sub-base port designations


Duct Function Description
[14] Control unit Pilot air supply for pilot valves 12 and 14
[5] Power unit Exhaust port
[4] Power unit Working port
[1] Power unit Working air supply port
[2] Power unit Working port
[3] Power unit Exhaust port
[12] Control unit Exhaust port for pilot air supply

6 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Key features
Pilot air supply
The pneumatic supply ports are locat- The port for the external pilot air sup-
ed on the right and left end plates and ply is on the right and left end plates. -H-  Note
on supply plates. Internal pilot air supply takes place in If a gradual pressure build-up is re-
The ports differ for the following types the valve itself and the ports for pilot quired in the system by using a soft-
of pilot air supply: air supply are not provided on the end start valve, then external pilot air
• Internal pilot air supply plates. should be selected whereby the pilot
• External pilot air supply pressure is already applied at the
point of switch-on.

Internal pilot air supply External pilot air supply


Internal pilot air supply can be select- In this case the pilot air supply is If the supply pressure is less than 2 or The pilot air supply is then supplied
ed if the working pressure is between branched from the compressed air 3 bar, you must operate your valve via ports 12 and 14 on the end plates.
2 and 10 bar, 3 and 10 bar, 2 and supply 1 using an internal connection manifold assembly VSVA using exter-
16 bar or 3 and 16 bar, depending on in the valve. nal pilot air supply.
the valve.

Using the seals with ducted/unducted pilot exhaust air


[1] Ducted pilot air exhaust Valve manifold assemblies VSVA are
[2] Turning the seal by 180° supplied with unducted pilot air ex-
[3] Unducted pilot air exhaust (as haust. By turning the seal between the
supplied) valve and manifold block, exhaust air
(pilot air) can be diverted into pilot
duct 12 and can thus be ducted and
2 silenced (see illustration).

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 7


Standards-based valves to ISO 5599-1

Key features
Pilot air supply via end plates
Description
Left end plate (graphical illustration)
Internal pilot air supply
• Pilot air supply is branched within the valve from port 1
• Port 12 is not available
• Port 14 is not available
• Exhaust air via ports 3 and 5
• Pilot exhaust air via port 12

External pilot air supply


• Pilot air supply via ports 12 and 14
• Exhaust air via ports 3 and 5
• Unducted pilot exhaust air

External pilot air supply, ducted pilot exhaust air


• Pilot air supply via port 14
• Exhaust air via ports 3 and 5
• Pilot exhaust air via port 12
• For valves with central plug M12, 3-pin

Right end plate (graphical representation)


Internal pilot air supply
• Pilot air supply is branched within the valve from port 1
• Port 12 is not available
• Port 14 is not available
• Exhaust air via ports 3 and 5
• Pilot exhaust air via port 12

External pilot air supply


• Pilot air supply via ports 12 and 14
• Exhaust air via ports 3 and 5
• Unducted pilot exhaust air

External pilot air supply, ducted pilot exhaust air


• Pilot air supply via port 14
• Exhaust air via ports 3 and 5
• Pilot exhaust air via port 12
• For valves with central plug M12, 3-pin

8 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Key features
Creating pressure zones and separating exhaust air

The valve manifold assembly VSVA Compressed air is supplied and ex- Duct separations are integrated ex-
offers a number of options for creating hausted via the end plates and supply works as per your order.
pressure zones if different working plates. Duct separations can be distinguished
pressures are required. The position of the supply plates and by their coding, even when the valve
Pressure zones are created by isolating duct separations can be freely manifold assembly is assembled.
the internal supply ducts between the selected.
manifold sub-bases by appropriate
duct separation.

Creating pressure zones


Separating seal Description
Coding Sample image Coding Basic representation
Duct 1 separate
• Different supply pressure for each pressure zone
• Supply pressure for each pressure zone can be switched off separately

Ducts 3 and 5 separated


• The valves (for different pressure zones) do not affect each other via the exhaust
ducts

Ducts 12 and 14 separated


• Different pilot pressure for each supply zone
• Operation with internal and external pilot air supply possible according to
pressure zone
• Pilot pressure for each pressure zone can be switched off separately

Ducts 1, 3 and 5 separated


• Different supply pressure for each pressure zone
• The valves (for different pressure zones) do not affect each other via the exhaust
ducts
• Supply pressure for each pressure zone can be switched off separately

Ducts 1, 3, 5, 12 and 14 separated


• Different supply pressure for each pressure zone
• Supply pressure for each pressure zone can be switched off separately
• The valves (for different pressure zones) do not affect each other via the exhaust
ducts
• Different pilot pressure for each supply zone
• Operation with internal and external pilot air supply possible according to
pressure zone
• Pilot pressure for each pressure zone can be switched off separately

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 9


Standards-based valves to ISO 5599-1

Key features
Examples: Creating pressure zones

[1] Pressure zone separation in ducts [2] Pressure zone separation in ducts [3] Pressure zone separation in duct
1, 3 and 5. Pressure supply and 3 and 5. The pressure for both 1. Pressure supply via the respec-
exhausting via the respective end pressure zones is supplied jointly tive end plate for each of the two
plate for each of the two pressure via the end plates. Exhausting for pressure zones. Both pressure
zones. Pilot air is supplied jointly each of the two pressure zones zones are exhausted jointly via
via the left end plate. takes places separately via the re- the end plates. Pilot air supplied
spective end plate. Pilot air is jointly via the left end plate.
supplied jointly via the left end
plate.
Potential benefit: Potential benefit: Potential benefit:
• Two different supply pressures • The valves do not affect each other • Two different supply pressures
• The valves do not affect each other via the exhaust ducts
via the exhaust ducts

10 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Key features
Use of 2x 3/2-way valve as 5/4-way valve
Code Symbol Table of values Equivalent circuit symbol Function
K • Normally exhausted
• The double-acting drive connected to ducts 2 and 4 is
unpressurised when the valve is in the normal position and
can be moved by an external force
• If there is a signal at Y1(14) and Y2(12), there is pressure at
ducts 2 and 4

• Normally closed (by combining valve code K and two piloted


check valves)
• The piloted check valves connected to ducts 2 and 4 are
unpressurised when the valve is in the normal position and
the pressures in the drive close the check valves leak-tight
• The drive remains stationary when the forces are in
equilibrium
• Leakages can only occur via the drive seals
• If there is a signal at Y1(14) and Y2(12), the pressure at
ducts 2 and 4 is the same

N • Normally open
• The double-acting drive connected to ducts 2 and 4 is sup-
plied with the same pressure at both ends when the valve is
in the normal position and remains stationary when the
forces are balanced
• If there is a signal at Y1(10) and Y2(10), ducts 2 and 4 are
exhausted, the drive is unpressurised and can be moved by
an external force

H • Normally open to duct 2


• The double-acting drive connected to ducts 2 and 4 is
supplied with pressure via duct 2 when the valve is in the
normal position. Duct 4 is exhausted. When the system is in
its initial position, the drive is thus in a clearly defined
position, as would also be the case with a 5/2-way single
solenoid valve
• If there is a signal at Y1(14) and Y2(10), duct 2 is exhausted
and there is pressure at duct 4. The drive leaves the initial
position
• A closed circuit can be created with this 2x 3/2-way valve by
combining it with piloted check valves. However, this is then
selected by an active signal at Y2(10).

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 11


Standards-based valves to ISO 5599-1

Product range overview


Function Type Valve function Flow rate Operating voltage a Page/
Valve Internet
[l/min]
Width 42 mm Valve with armature tube for solenoid coil MSN
MN1H-5/2 5/2-way valve, single solenoid 1200 12 V DC, 24 V DC, 24 V AC, 22
Working port JMN1 5/2-way valve, double solenoid 1200 110 V AC, 230 V AC
G1/4 MN1H-5/3 5/3-way solenoid valve, mid-position valve 1200

Valve with armature tube for solenoid coil MSF


MFH-5/2 5/2-way valve, single solenoid 1200 12 V DC, 24 V DC, 42 V DC, 34
JMF 5/2-way valve, double solenoid 1200 24 V AC, 42 V AC, 48 V AC,
MFH-5/3 5/3-way solenoid valve, mid-position valve 1200 110 V AC, 120 V AC, 230 V AC,
240 V AC
Valve with central plug M12, 3-pin
VSVA-B-T22 2x 2/2-way valve, single solenoid 1300 24 V DC 46
VSVA-B-T32 2x 3/2-way valve, single solenoid 1100
VSVA-B-M52 5/2-way valve, single solenoid 1300
VSVA-B-B52 5/2-way valve, double solenoid 1300
VSVA-B-D52 5/2-way valve, double solenoid 1300
VSVA-B-P53 5/3-way solenoid valve, mid-position valve 1300
Valve with individual plug M12
MDH-5/2 5/2-way valve, single solenoid 1200 24 V DC, 42 V AC, 110 V AC, 61
JMD 5/2-way valve, double solenoid 1200 230 V AC
MDH-5/3 5/3-way solenoid valve, mid-position valve 1200

Pneumatic valve
VL-5/2 5/2-way pneumatic valve, monostable 1200 – 80
J 5/2-way pneumatic valve, bistable 1200
VL-5/3 5/3-way pneumatic valve, mid-position valve 1200

12 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Product range overview


Function Type Valve function Flow rate Operating voltage a Page/
Valve Internet
[l/min]
Width 52 mm Valve with armature tube for solenoid coil MSN
MN1H-5/2 5/2-way valve, single solenoid 2300 12 V DC, 24 V DC, 24 V AC, 26
Working port JMN1 5/2-way valve, double solenoid 2300 110 V AC, 230 V AC
G3/8 MN1H-5/3 5/3-way solenoid valve, mid-position valve 2300

Valve with armature tube for solenoid coil MSF


MFH-5/2 5/2-way valve, single solenoid 2300 12 V DC, 24 V DC, 42 V DC, 38
JMF 5/2-way valve, double solenoid 2300 24 V AC, 42 V AC, 48 V AC,
MFH-5/3 5/3-way solenoid valve, mid-position valve 2300 110 V AC, 120 V AC, 230 V AC,
240 V AC
Valve with central plug M12, 3-pin
VSVA-B-T22 2x 2/2-way valve, single solenoid 2800 24 V DC 52
VSVA-B-T32 2x 3/2-way valve, single solenoid 2200
VSVA-B-M52 5/2-way valve, single solenoid 2800
VSVA-B-B52 5/2-way valve, double solenoid 2800
VSVA-B-D52 5/2-way valve, double solenoid 2800
VSVA-B-P53 5/3-way solenoid valve, mid-position valve 2700
Valve with individual plug M12
MDH-5/2 5/2-way valve, single solenoid 2300 24 V DC, 42 V AC, 110 V AC, 65
JMD 5/2-way valve, double solenoid 2300 230 V AC
MDH-5/3 5/3-way solenoid valve, mid-position valve 2300

Pneumatic valve
VL-5/2 5/2-way pneumatic valve, monostable 2300 – 85
J 5/2-way pneumatic valve, bistable 2300
VL-5/3 5/3-way pneumatic valve, mid-position valve 2300

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 13


Standards-based valves to ISO 5599-1

Product range overview


Function Type Valve function Flow rate Operating voltage a Page/
Valve Internet
[l/min]
Width 65 mm Valve with armature tube for solenoid coil MSN
MN1H-5/2 5/2-way valve, single solenoid 4500 12 V DC, 24 V DC, 24 V AC, 30
Working port JMN1 5/2-way valve, double solenoid 4500 110 V AC, 230 V AC
G1/2 MN1H-5/3 5/3-way solenoid valve, mid-position valve 4000

Valve with armature tube for solenoid coil MSF


MFH-5/2 5/2-way valve, single solenoid 4500 12 V DC, 24 V DC, 42 V DC, 42
JMF 5/2-way valve, double solenoid 4500 24 V AC, 42 V AC, 48 V AC,
MFH-5/3 5/3-way solenoid valve, mid-position valve 4000 110 V AC, 120 V AC, 230 V AC,
240 V AC
Valve with central plug M12, 4-pin
MEBH-5/2 5/2-way valve, single solenoid 4500 24 V DC 57
JMEB 5/2-way valve, double solenoid 4500
MEBH-5/3 5/3-way solenoid valve, mid-position valve 4000

Valve with individual plug M12


MDH-5/2 5/2-way valve, single solenoid 4500 24 V DC, 42 V AC, 110 V AC, 69
JMD 5/2-way valve, double solenoid 4500 230 V AC
MDH-5/3 5/3-way solenoid valve, mid-position valve 4000

Pneumatic valve
VL-5/2 5/2-way pneumatic valve, monostable 4500 – 90
J 5/2-way pneumatic valve, bistable 4500
VL-5/3 5/3-way pneumatic valve, mid-position valve 4100

Width 76 mm Valve with individual plug M12


MDH-5/2 5/2-way valve, single solenoid 6000 24 V DC, 42 V AC, 110 V AC, 73
Working port JMD 5/2-way valve, double solenoid 6000 230 V AC
G3/4 MDH-5/3 5/3-way solenoid valve, mid-position valve 4800

Pneumatic valve
VL-5/2 5/2-way pneumatic valve, monostable 6000 – 94
J 5/2-way pneumatic valve, bistable 6000
VL-5/3 5/3-way pneumatic valve, mid-position valve 4800

14 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12

Type codes for valves with round plug


001 Series 005 Pilot air
VSVA Standards-based valve to ISO 5599-1 Internal
Z External
002 Directional control valve type
B Sub-base valve 006 Manual override
H Non-detenting
003 Valve function D Non-detenting, detenting
T22C 2x2/2-way valve, normally closed
T32U 2x3/2-way valve, normally open 007 Pneumatic connection
T32F 2x3/2-way valve, normally open, reversible A2 18 mm (02) ISO 15407-1/-2
T32C 2x3/2-way valve, normally closed A1 26 mm (01) ISO 15407-1/-2
T32N 2x3/2-way valve, normally closed, reversible D1 42 mm (1) ISO 5599-1/-2
T32H 2x3/2-way valve, 1x normally closed, 1x normally open D2 52 mm (2) ISO 5599-1/-2
T32W 2x3/2-way valve, 1x normally closed, 1x normally open, reversible
M52 5/2-way valve, single solenoid/monostable 008 Nominal operating voltage
B52 5/2-way valve, double solenoid/bistable 1 24 V DC
D52 5/2-way valve, double solenoid/bistable, dominant signal
P53U 5/3-way valve, mid-position pressurised 009 Electrical connection
P53E 5/3-way valve, mid-position exhausted| R2 Central connector M8
P53C 5/3-way valve, mid-position closed R5 Central plug M12

004 Reset method for monostable/single solenoid valves 010 Display


None L LED
A Pneumatic spring
M Mechanical spring

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 15


Standards-based valves to ISO 5599-1

Peripherals overview

Valve on individual sub-base


Solenoid valve with solenoid coil MSN1 Solenoid valve with central plug M12, 3-pin

6 11
10
7
7
5
8 4
4
8

9 1
4 4

1
2 3

2 3
4
3

Individual components
Type Brief description a Page/
Internet
[1] Solenoid valve MN1H-... Solenoid valve with solenoid coil, port pattern to ISO 5599-1, corresponding solenoid 22
coils a page 139
Solenoid valve VSVA-... Solenoid valve with central plug M12, 3-pin, port pattern to ISO 5599-1 46
[2] Sub-base VABS-S1-... Lateral pneumatic connections 97
Individual sub-base NAS-... Lateral pneumatic connections 97
NAU-... Pneumatic connections underneath 100
[3] Silencer U-... For mounting in exhaust ports silencer
[4] Push-in fitting QS-... For connecting tubing with standard O.D. qs
[5] Connecting cable KMC-..., NEBV-... Without LED 130
[6] Connecting cable KMC-..., NEBV-... With LED 130
[7] Plug socket MSSD-... For self-assembly 130
[8] Illuminating seal M...-LD For displaying the signal status 130
[9] Manual override AHB-... Tool for detenting manual override 131
[10] Connecting cable NEBU-... – 131
[11] Plug socket SIE-... For self-assembly 131

Valve variants
MN1H, JMN1H, MFH, JMFH VSVA MEBH, JMEBH MDH, JMDH

16 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Peripherals overview
Accessories

8
7
11
10 6
5 6
9
3 4

2
2

12
1

Individual components
Type Brief description a Page/
Internet
[1] Silencer U-... For mounting in exhaust ports silencer
[2] Push-in fitting QS-... For connecting tubing with standard O.D. qs
[3] Pressure gauge PAGN-... With push-in connector 131
[4] Connecting cable KMC-..., NEBV-... Without LED 130
[5] Connecting cable KMC-...LED, NEBV-... With LED 130
[6] Illuminating seal M...-LD For displaying the signal status 130
[7] Socket MSSD-C-M16 With screw terminal connection 130
[8] Socket MSSD-C-S-M16 With insulation displacement connection 130
[9] Connecting cable NEBU-... Angled socket, M12x1, 5-pin 131
[10] Socket SIE-... For self-assembly 131
[11] Connecting cable NEBU-... Straight socket, M12x1, 5-pin 131
[12] Blanking plug B-... For sealing unused connections b

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 17


Standards-based valves to ISO 5599-1

System overview
Manifold assembly

6
6

6 7

3
8

2 4
10

18 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

System overview
Individual components
Type Brief description a Page/
Internet
[1] Solenoid valve MN1H-... With armature tube for solenoid coil MSN1 22
JMN1H-... With armature tube for solenoid coil MSN1 22
JMN1DH-... With armature tube for solenoid coil MSN1 22
MFH-... With armature tube for solenoid coil MSF 34
JMFH-... With armature tube for solenoid coil MSF 34
JMFDH-... With armature tube for solenoid coil MSF 34
VSVA-... With central plug M12, 3-pin 46
MEBH-... With central plug M12, 4-pin 57
JMEBH-... With central plug M12, 4-pin 57
JMEBDH-... With central plug M12, 4-pin 57
MDH-... With solenoid coil MD with round plug M12x1 61
JMDH-... With solenoid coil MD with round plug M12x1 61
JMDDH-... With solenoid coil MD with round plug M12x1 61
Pneumatic valve VL-... Port pattern to ISO 5599-1 80
J-... Port pattern to ISO 5599-1 80
JD-... Port pattern to ISO 5599-1 80
[2] Cover plate NDV-... For sealing unused manifold sub-bases 112
[3] Throttle plate VABF-S1-...-F1B1-C Controls the flow of exhaust air in ducts 3 and 5 116
GRO-ZP-... Controls the flow of exhaust air in ducts 3 and 5 116
[4] Vertical supply plate VABF-S1-...-P1A3-G38 Alternative compressed air supply for port 1 of the mounted valve 119
[5] Vertical pressure shut-off plate VABF-S1-...-L1D1-C For blocking duct 1 and duct 14 upstream of a valve 121
[6] Regulator plate VABF-S1-...-R... Pressure regulator for manually setting a particular pressure in the regulated port 123
upstream or downstream of the valve
LR-ZP-... Pressure regulator for manually setting a particular pressure in the regulated port 123
upstream or downstream of the valve
[7] End plate VABE-S1-... With ports for air supply 1 and exhausts 3 and 5 and pilot air supply 12 and 14 109
[8] Manifold sub-base VABV-S1-... With ports 2 and 4 underneath 102
[9] Duct separation VABD-S1-1-... For sealing ducts 1, 3, 5, 12 and 14 between end plate and manifold sub-base, e.g. to 113
create pressure zones
[10] Supply plate VABF-S1-1-... With ports for air supply 1 and exhausts 3 and 5 104

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 19


Standards-based valves to ISO 5599-1

System overview
Manifold assembly

6 6

2
4 7

8
9

20 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

System overview
Individual components
Type Brief description a Page/
Internet
[1] Solenoid valve MN1H-... With armature tube for solenoid coil MSN1 22
JMN1H-... With armature tube for solenoid coil MSN1 22
JMN1DH-... With armature tube for solenoid coil MSN1 22
MFH-... With armature tube for solenoid coil MSF 34
JMFH-... With armature tube for solenoid coil MSF 34
JMFDH-... With armature tube for solenoid coil MSF 34
VSVA-... With central plug M12, 3-pin 46
MEBH-... With central plug M12, 4-pin 57
JMEBH-... With central plug M12, 4-pin 57
JMEBDH-... With central plug M12, 4-pin 57
MDH-... With solenoid coil MD with round plug M12x1 61
JMDH-... With solenoid coil MD with round plug M12x1 61
JMDDH-... With solenoid coil MD with round plug M12x1 61
Pneumatic valve VL-... Port pattern to ISO 5599-1 80
J-... Port pattern to ISO 5599-1 80
JD-... Port pattern to ISO 5599-1 80
[2] Cover plate NDV-... For sealing unused manifold sub-bases 112
[3] Throttle plate VABF-S1-...-F1B1-C Controls the flow of exhaust air in ducts 3 and 5 116
GRO-ZP-... Controls the flow of exhaust air in ducts 3 and 5 116
[4] Vertical supply plate VABF-S1-...-P1A3-G38 Alternative compressed air supply for port 1 of the mounted valve 119
[5] Vertical pressure shut-off plate VABF-S1-...-L1D1-C For blocking duct 1 and duct 14 upstream of a valve 121
[6] Regulator plate VABF-S1-...-R... Pressure regulator for manually setting a particular pressure in the regulated port 123
upstream or downstream of the valve
LR-ZP-... Pressure regulator for manually setting a particular pressure in the regulated port 123
upstream or downstream of the valve
[7] End plate kit NEV-... With ports for air supply 1 and exhausts 3 and 5 108
[8] Manifold sub-base NAV-... With ports 2 and 4 underneath 102
[9] Isolating disc NSC-... For sealing ducts 1, 3, 5 between end plate and manifold sub-base, e.g. to create 112
pressure zones

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 21


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 42 mm

-M- Flow rate


1200 l/min

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow With external pilot air supply Reversible
With internal pilot air supply Not reversible
Exhaust function Can be throttled
Manual override Non-detenting, detenting via accessory
Type of mounting On sub-base, via through-hole
Mounting position Any
Nominal size [mm] 8
Overlap Positive overlap
Width [mm] 42
Grid dimension [mm] 43
Pneumatic connections Sub-base size 1 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1
Certification With internal pilot air supply c UL us - Recognized (OL)
Maritime classification1) See certificate

1) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Flow rates
Valve function 5/2-way valve, single 5/2-way valve, double 5/3-way valve
solenoid solenoid
Standard nominal flow rate [l/min] 1200

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover (domi-
nant)
5/2-way valve, single solenoid MN1H-5/2-D-1-C 23 32 – –
MN1H-5/2-D-1-S-C 23 32 – –
MN1H-5/2-D-1-FR-C 17 39 – –
MN1H-5/2-D-1-FR-S-C 17 39 – –
5/2-way valve, double solenoid JMN1H-5/2-D-1-C – – 18 –
JMN1H-5/2-D-1-S-C – – 18 –
JMN1DH-5/2-D-1-C – – 18 15
JMN1DH-5/2-D-1-S-C – – 18 15
5/3-way valve MN1H-5/3G-D-1-C 20 44 – –
MN1H-5/3G-D-1-S-C 20 44 – –
MN1H-5/3E-D-1-C 20 46 – –
MN1H-5/3E-D-1-S-C 20 46 – –
MN1H-5/3B-D-1-C 20 46 – –
MN1H-5/3B-D-1-S-C 20 46 – –

22 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 42 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +50
Temperature of medium [°C] –5 ... +50
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 3700
Max. negative test pulse with 1 signal [µs] 4600
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection Via N1 coil, to be ordered separately
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 23


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 42 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
MN1H-5/2- ... 42 28 6 30 M5 M5 106 74 38 9 46.5 15.3 117.5 87.6 43.8 36 18 89
MN1H-5/2- ... -FR- ... 128 98

5/2-way double solenoid valves, 5/3-way valves


[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
JMN1H-5/2- ... 42 28 6 30 M5 M5 106 74 38 9 46.5 15.3 147.3 87.6 43.8 36 18 89
JMN1DH-5/2- ... 87.6
MN1H-5/3... 108.4

24 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Ordering data – Width 42 mm


Ordering data – Valves with armature tube for solenoid coil MSN11)
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 450 159688 MN1H-5/2-D-1-C

Pneumatic spring reset External 450 159686 MN1H-5/2-D-1-S-C

Mechanical spring reset Internal 450 159687 MN1H-5/2-D-1-FR-C

Mechanical spring reset External 450 159716 MN1H-5/2-D-1-FR-S-C

5/2-way valve, double solenoid


– Internal 610 159690 JMN1H-5/2-D-1-C

– External 610 159689 JMN1H-5/2-D-1-S-C

With dominant signal at 14 Internal 610 159691 JMN1DH-5/2-D-1-C

With dominant signal at 14 External 610 159717 JMN1DH-5/2-D-1-S-C

5/3-way valve
Normally closed, Internal 650 159681 MN1H-5/3G-D-1-C
Mechanical spring reset

Normally closed, External 650 159680 MN1H-5/3G-D-1-S-C


Mechanical spring reset

Normally exhausted, Internal 650 159683 MN1H-5/3E-D-1-C


Mechanical spring reset

Normally exhausted, External 650 159682 MN1H-5/3E-D-1-S-C


Mechanical spring reset

Normally open, Internal 650 159685 MN1H-5/3B-D-1-C


Mechanical spring reset

Normally open, External 650 159684 MN1H-5/3B-D-1-S-C


Mechanical spring reset

1) Solenoid coils a page 129

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 25


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 52 mm

-M- Flow rate


2300 l/min

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow With external pilot air supply Reversible
With internal pilot air supply Not reversible
Exhaust function Can be throttled
Manual override Non-detenting, detenting via accessory
Type of mounting On sub-base, with through-hole and screw
Mounting position Any
Nominal size [mm] 11.5
Overlap Positive overlap
Width [mm] 52
Grid dimension [mm] 56
Pneumatic connections Sub-base size 2 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1
Certification With internal pilot air supply c UL us - Recognized (OL)
Maritime classification1) See certificate

1) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Flow rates
Valve function 5/2-way valve, single 5/2-way valve, double 5/3-way valve
solenoid solenoid
Standard nominal flow rate [l/min] 2300

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MN1H-5/2-D-2-C 46 69 – –
MN1H-5/2-D-2-S-C 43 62 – –
MN1H-5/2-D-2-FR-C 24 62 – –
MN1H-5/2-D-2-FR-S-C 24 62 – –
5/2-way valve, double solenoid JMN1H-5/2-D-2-C – – 21 –
JMN1H-5/2-D-2-S-C – – 21 –
JMN1DH-5/2-D-2-C – – 24 21
JMN1DH-5/2-D-2-S-C – – 24 21
5/3-way valve MN1H-5/3G-D-2-C 33 82 – –
MN1H-5/3G-D-2-S-C 33 82 – –
MN1H-5/3E-D-2-C 36 84 – –
MN1H-5/3E-D-2-S-C 36 84 – –
MN1H-5/3B-D-2-C 35 78 – –
MN1H-5/3B-D-2-S-C 35 78 – –

26 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 52 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +50
Temperature of medium [°C] –5 ... +50
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 3700
Max. negative test pulse with 1 signal [µs] 4600
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection Via N1 coil, to be ordered separately
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 27


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 52 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
MN1H-5/2- ... 54 38 9 30 M6 M5 116 84 48 9.5 56.5 15.3 147.6 123.4 61.7 48 24 98
MN1H-5/2- ... -FR- ... 161.5 140.7

5/2-way double solenoid valves, 5/3-way valves


[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
JMN1H-5/2- ... 54 38 9 30 M6 M5 116 84 48 9.5 56.5 15.3 165 123.4 61.7 48 24 98
JMN1DH-5/2- ... 123.4 61.7
MN1H-5/3... 158 79

28 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Ordering data – Width 52 mm


Ordering data – Valves with armature tube for solenoid coil MSN11)
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 710 159700 MN1H-5/2-D-2-C

Pneumatic spring reset External 710 159698 MN1H-5/2-D-2-S-C

Mechanical spring reset Internal 710 159699 MN1H-5/2-D-2-FR-C

Mechanical spring reset External 710 159718 MN1H-5/2-D-2-FR-S-C

5/2-way valve, double solenoid


– Internal 940 159702 JMN1H-5/2-D-2-C

– External 940 159701 JMN1H-5/2-D-2-S-C

With dominant signal at 14 Internal 940 159703 JMN1DH-5/2-D-2-C

With dominant signal at 14 External 940 159719 JMN1DH-5/2-D-2-S-C

5/3-way valve
Normally closed, Internal 940 159693 MN1H-5/3G-D-2-C
Mechanical spring reset

Normally closed, External 940 159692 MN1H-5/3G-D-2-S-C


Mechanical spring reset

Normally exhausted, Internal 940 159695 MN1H-5/3E-D-2-C


Mechanical spring reset

Normally exhausted, External 940 159694 MN1H-5/3E-D-2-S-C


Mechanical spring reset

Normally open, Internal 940 159697 MN1H-5/3B-D-2-C


Mechanical spring reset

Normally open, External 940 159696 MN1H-5/3B-D-2-S-C


Mechanical spring reset

1) Solenoid coils a page 129

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 29


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 65 mm

-M- Flow rate


4600 l/min

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow With external pilot air supply Reversible
With internal pilot air supply Not reversible
Exhaust function Can be throttled
Manual override Non-detenting, detenting via accessory
Type of mounting On sub-base, with through-hole and screw
Mounting position Any
Nominal size [mm] 14.5
Overlap Positive overlap
Width [mm] 65
Grid dimension [mm] 71
Pneumatic connections Sub-base size 3 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1
Certification With internal pilot air supply c UL us - Recognized (OL)
Maritime classification1) See certificate

1) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Flow rates
Valve function 5/2-way valve 5/3-way valve
Normally closed Normally exhausted Normally open
Standard nominal flow rate [l/min] 4500 4100 4600 4000

30 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 65 mm


Switching times [ms]
Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MN1H-5/2-D-3-C 49 71 – –
MN1H-5/2-D-3-S-C 49 71 – –
MN1H-5/2-D-3-FR-C 33 74 – –
MN1H-5/2-D-3-FR-S-C 33 74 – –
5/2-way valve, double solenoid JMN1H-5/2-D-3-C – – 21 –
JMN1H-5/2-D-3-S-C – – 21 –
JMN1DH-5/2-D-3-C – – 24 21
JMN1DH-5/2-D-3-S-C – – 24 21
5/3-way valve MN1H-5/3G-D-3-C 33 82 – –
MN1H-5/3G-D-3-S-C 33 82 – –
MN1H-5/3E-D-3-C 36 84 – –
MN1H-5/3E-D-3-S-C 36 84 – –
MN1H-5/3B-D-3-C 35 78 – –
MN1H-5/3B-D-3-S-C 35 78 – –

Operating and environmental conditions


Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +50
Temperature of medium [°C] –5 ... +50
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 3700
Max. negative test pulse with 1 signal [µs] 4600
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection Via N1 coil, to be ordered separately
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 31


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Technical data – Width 65 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
MN1H-5/2- ... 65 48 12 30 M8 M5 123 87.3 55 12 63.5 15.3 169 145.4 72.7 64 32 109
MN1H-5/2- ... -FR- ... 184.8 164.7

5/2-way double solenoid valves, 5/3-way valves


[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
JMN1H-5/2- ... 65 48 12 30 M8 M5 123 87.3 55 12 – 15.3 185.7 145.4 72.7 64 32 109
JMN1DH-5/2- ... – 145.4 72.7
MN1H-5/3... 63.5 184 92

32 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSN1

Ordering data – Width 65 mm


Ordering data – Valves with armature tube for solenoid coil MSN11)
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 1000 159712 MN1H-5/2-D-3-C

Pneumatic spring reset External 1000 159710 MN1H-5/2-D-3-S-C

Mechanical spring reset Internal 1000 159711 MN1H-5/2-D-3-FR-C

Mechanical spring reset External 1000 160896 MN1H-5/2-D-3-FR-S-C

5/2-way valve, double solenoid


– Internal 1090 159714 JMN1H-5/2-D-3-C

– External 1090 159713 JMN1H-5/2-D-3-S-C

With dominant signal at 14 Internal 1090 159715 JMN1DH-5/2-D-3-C

With dominant signal at 14 External 1090 160897 JMN1DH-5/2-D-3-S-C

5/3-way valve
Normally closed, Internal 1170 159705 MN1H-5/3G-D-3-C
Mechanical spring reset

Normally closed, External 1170 159704 MN1H-5/3G-D-3-S-C


Mechanical spring reset

Normally exhausted, Internal 1170 159707 MN1H-5/3E-D-3-C


Mechanical spring reset

Normally exhausted, External 1170 159706 MN1H-5/3E-D-3-S-C


Mechanical spring reset

Normally open, Internal 1170 159709 MN1H-5/3B-D-3-C


Mechanical spring reset

Normally open, External 1170 159708 MN1H-5/3B-D-3-S-C


Mechanical spring reset

1) Solenoid coils a page 129

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 33


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 42 mm

-M- Flow rate


1200 l/min

General technical data


Type MFH- ...  -C, JMF- ...  -C MFH- ...  -EX, JMF- ...  -EX
Design Piston spool Piston spool
Sealing principle Soft Soft
Actuation type Electrical Electrical
Type of control Piloted Piloted
Direction of flow With external pilot air supply Reversible Reversible
With internal pilot air supply Not reversible Not reversible
Exhaust function Can be throttled Can be throttled
Manual override Non-detenting, detenting via accessory Non-detenting, detenting via accessory
Type of mounting On sub-base, via through-hole
Mounting position Any Any
Nominal size [mm] 8 8
Overlap Positive overlap Positive overlap
Width [mm] 42 42
Grid dimension [mm] 43 43
Pneumatic connections Sub-base size 1 to ISO 5599-1 Sub-base size 1 to ISO 5599-1
Noise level [dB (A)] 85 85
Conforms to standard ISO 5599-1 ISO 5599-1
Maritime classification1) See certificate –

1) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Flow rates
Valve function 5/2-way valve, single 5/2-way valve, double 5/3-way valve
solenoid solenoid
Standard nominal flow rate [l/min] 1200

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MFH-5/2-... 23 35 – –
MFH-5/2-D-1-FR-... 16 45 – –
5/2-way valve, double solenoid JMFH-... – – 16 –
JMFDH-... – – 16 13
5/3-way valve MFH-5/3G-D-1-C 18 35 – –
MFH-5/3G-D-1-C-EX 18 35 – –
MFH-5/3G-D-1-S-C 18 36 – –
MFH-5/3G-D-1-S-C-EX 18 36 – –
MFH-5/3E-D-1-C 18 36 – –
MFH-5/3E-D-1-C-EX 18 36 – –
MFH-5/3E-D-1-S-C 18 36 – –
MFH-5/3E-D-1-S-C-EX 18 36 – –
MFH-5/3B-D-1-C 18 36 – –
MFH-5/3B-D-1-C-EX 18 36 – –
MFH-5/3B-D-1-S-C 18 36 – –
MFH-5/3B-D-1-S-C-EX 18 36 – –

34 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 42 mm


ATEX
Type MFH- ...  -EX, JMFH- ...  -EX, JMFDH- ...  -EX
ATEX category for gas II 2G
Type of ignition protection for gas Ex h IIC T4 Gb
ATEX category for dust II 2D
Type of ignition protection for dust Ex h IIIC T105°C Db
Explosion-proof ambient temperature [°C] –5 <= Ta <= +40
CE marking (see declaration of conformity) To EU Explosion Protection Directive (ATEX)

Operating and environmental conditions


Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +40
Temperature of medium [°C] –10 ... +60
[°C] –5 ... +40 (MFH- ...  -EX, JMFH- ...  -EX, JMFDH- ...  -EX)
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 2200
Max. negative test pulse with 1 signal [µs] 3700
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection Via F coil, to be ordered separately
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 35


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 42 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
MFH-5/2- ... 42 28 6 30 M5 M5 100 70.3 38 9 46.5 13.5 115 87.6 43.8 36 18 89
MFH-5/2- ... -FR- ... 125.6 98

5/2-way double solenoid valves, 5/3-way valves


[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
JMFH-5/2- ... 42 28 6 30 M5 M5 100 70.3 38 9 – 13.5 142.6 87.6 43.8 36 18 89
JMFDH-5/2- ... 87.6 43.8
MFH-5/3... 108.4 54.2

36 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSF

Ordering data – Width 42 mm


Ordering data – Valves with armature tube for solenoid coil MSF1)
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 390 – 150981 MFH-5/2-D-1-C
ATEX category 535954 MFH-5/2-D-1-C-EX
a page 35
Pneumatic spring reset External 390 – 152562 MFH-5/2-D-1-S-C
ATEX category 535957 MFH-5/2-D-1-S-C-EX
a page 35
Mechanical spring reset Internal 390 – 151016 MFH-5/2-D-1-FR-C
ATEX category 535960 MFH-5/2-D-1-FR-C-EX
a page 35
Mechanical spring reset External 390 – 188510 MFH-5/2-D-1-FR-S-C

5/2-way valve, double solenoid


– Internal 490 – 150980 JMFH-5/2-D-1-C
ATEX category 535963 JMFH-5/2-D-1-C-EX
a page 35
– External 490 – 152563 JMFH-5/2-D-1-S-C
ATEX category 535966 JMFH-5/2-D-1-S-C-EX
a page 35
With dominant signal at Internal 490 – 151019 JMFDH-5/2-D-1-C
14 ATEX category 536071 JMFDH-5/2-D-1-C-EX
a page 35

5/3-way valve
Normally closed, Internal 520 – 150982 MFH-5/3G-D-1-C
Mechanical spring reset ATEX category 535969 MFH-5/3G-D-1-C-EX
a page 35
Normally closed, External 520 – 152564 MFH-5/3G-D-1-S-C
Mechanical spring reset ATEX category 535972 MFH-5/3G-D-1-S-C-EX
a page 35
Normally exhausted, Internal 520 – 150983 MFH-5/3E-D-1-C
Mechanical spring reset ATEX category 535975 MFH-5/3E-D-1-C-EX
a page 35
Normally exhausted, External 520 – 152565 MFH-5/3E-D-1-S-C
Mechanical spring reset ATEX category 535978 MFH-5/3E-D-1-S-C-EX
a page 35
Normally open, Internal 520 – 150984 MFH-5/3B-D-1-C
Mechanical spring reset ATEX category 535981 MFH-5/3B-D-1-C-EX
a page 35
Normally open, External 520 – 152566 MFH-5/3B-D-1-S-C
Mechanical spring reset ATEX category 535984 MFH-5/3B-D-1-S-C-EX
a page 35

1) Solenoid coils a page 129

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 37


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 52 mm

-M- Flow rate


2300 l/min

General technical data


Type MFH- ...  -C, JMF- ...  -C MFH- ...  -EX, JMF- ...  -EX
Design Piston spool Piston spool
Sealing principle Soft Soft
Actuation type Electrical Electrical
Type of control Piloted Piloted
Direction of flow With external pilot air supply Reversible Reversible
With internal pilot air supply Not reversible Not reversible
Exhaust function Can be throttled Can be throttled
Manual override Non-detenting, detenting via accessory Non-detenting, detenting via accessory
Type of mounting On sub-base, with through-hole and screw
Mounting position Any Any
Nominal size [mm] 11.5 11.5
Overlap Positive overlap Positive overlap
Width [mm] 52 52
Grid dimension [mm] 56 56
Pneumatic connections Sub-base size 2 to ISO 5599-1 Sub-base size 2 to ISO 5599-1
Noise level [dB (A)] 85 85
Conforms to standard ISO 5599-1 ISO 5599-1
Maritime classification1) See certificate –

1) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Flow rates
Valve function 5/2-way valve, single 5/2-way valve, double 5/3-way valve
solenoid solenoid
Standard nominal flow rate [l/min] 2300

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MFH-5/2-... 48 71 – –
MFH-5/2-D-2-FR-... 27 73 – –
5/2-way valve, double solenoid JMFH-... – – 18 –
JMFDH-... – – 18 18
5/3-way valve MFH-5/3G-... 33 63 – –
MFH-5/3E-... 35 67 – –
MFH-5/3B-... 35 69 – –

ATEX
Type MFH- ...  -EX, JMFH- ...  -EX, JMFDH- ...  -EX
ATEX category for gas II 2G
Type of ignition protection for gas Ex h IIC T4 Gb
ATEX category for dust II 2D
Type of ignition protection for dust Ex h IIIC T105°C Db
Explosion-proof ambient temperature [°C] –5 <= Ta <= +40
CE marking (see declaration of conformity) To EU Explosion Protection Directive (ATEX)

38 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 52 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
Operating pressure External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +40
Temperature of medium [°C] –10 ... +60
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 2200
Max. negative test pulse with 1 signal [µs] 3700
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection Via F coil, to be ordered separately
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 39


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 52 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
MFH-5/2- ... 54 38 9 30 M6 M5 110 80.3 48 9.5 56.5 13.5 142 123.4 61.7 48 24 98
MFH-5/2- ... -FR- ... 159.4 140.7

5/2-way double solenoid valves, 5/3-way valves


[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
JMFH-5/2- ... 54 38 9 30 M6 M5 110 80.3 48 9.5 – 13.5 160.4 123.4 61.7 48 24 97
JMFDH-5/2- ... 160.4 123.4 61.7 97
MFH-5/3... 160 158 79 98

40 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSF

Ordering data – Width 52 mm


Ordering data – Valves with armature tube for solenoid coil MSF1)
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 650 – 151851 MFH-5/2-D-2-C
ATEX category 535955 MFH-5/2-D-2-C-EX
apage 38
Pneumatic spring reset External 650 – 151022 MFH-5/2-D-2-S-C
ATEX category 535958 MFH-5/2-D-2-S-C-EX
apage 38
Mechanical spring reset Internal 650 – 151709 MFH-5/2-D-2-FR-C
ATEX category 535961 MFH-5/2-D-2-FR-C-EX
apage 38

5/2-way valve, double solenoid


– Internal 820 – 151852 JMFH-5/2-D-2-C
ATEX category 535964 JMFH-5/2-D-2-C-EX
apage 38
– External 820 – 151023 JMFH-5/2-D-2-S-C
ATEX category 535967 JMFH-5/2-D-2-S-C-EX
apage 38
With dominant signal at Internal 820 – 151853 JMFDH-5/2-D-2-C
14 ATEX category 536072 JMFDH-5/2-D-2-C-EX
apage 38

5/3-way valve
Normally closed, Internal 820 – 151854 MFH-5/3G-D-2-C
Mechanical spring reset ATEX category 535970 MFH-5/3G-D-2-C-EX
apage 38
Normally closed, External 820 – 151024 MFH-5/3G-D-2-S-C
Mechanical spring reset ATEX category 535973 MFH-5/3G-D-2-S-C-EX
apage 38
Normally exhausted, Internal 820 – 151855 MFH-5/3E-D-2-C
Mechanical spring reset ATEX category 535976 MFH-5/3E-D-2-C-EX
apage 38
Normally exhausted, External 820 – 151025 MFH-5/3E-D-2-S-C
Mechanical spring reset ATEX category 535979 MFH-5/3E-D-2-S-C-EX
apage 38
Normally open, Internal 820 – 151856 MFH-5/3B-D-2-C
Mechanical spring reset ATEX category 535982 MFH-5/3B-D-2-C-EX
apage 38
Normally open, External 820 – 151026 MFH-5/3B-D-2-S-C
Mechanical spring reset ATEX category 535985 MFH-5/3B-D-2-S-C-EX
apage 38

1) Solenoid coils a page 129

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 41


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 65 mm

-M- Flow rate


Up to 4600 l/min

General technical data


Type MFH- ...  -C, JMF- ...  -C MFH- ...  -EX, JMF- ...  -EX
Design Piston spool Piston spool
Sealing principle Soft Soft
Actuation type Electrical Electrical
Type of control Piloted Piloted
Direction of flow With external pilot air supply Reversible Reversible
With internal pilot air supply Not reversible Not reversible
Exhaust function Can be throttled Can be throttled
Manual override Non-detenting, detenting via accessory Non-detenting, detenting via accessory
Type of mounting On sub-base, with through-hole and screw
Mounting position Any Any
Nominal size [mm] 14.5 14.5
Overlap Positive overlap Positive overlap
Width [mm] 65 65
Grid dimension [mm] 71 71
Pneumatic connections Sub-base size 3 to ISO 5599-1 Sub-base size 3 to ISO 5599-1
Noise level [dB (A)] 85 85
Conforms to standard ISO 5599-1 ISO 5599-1
Maritime classification1) See certificate –

1) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Flow rates
Valve function 5/2-way valve 5/3-way valve
Normally closed Normally exhausted Normally open
Standard nominal flow rate [l/min] 4500 4100 4600 4000

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MFH-5/2-... 60 66 – –
MFH-5/2-D-1-FR-... 28 79 – –
5/2-way valve, double solenoid JMFH-... – – 18 –
JMFDH-... – – 18 18
5/3-way valve MFH-5/3G-... 36 77 – –
MFH-5/3E-... 37 78 – –
MFH-5/3B-... 36 75 – –

42 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 65 mm


ATEX
Type MFH- ...  -EX, JMFH- ...  -EX, JMFDH- ...  -EX
ATEX category for gas II 2G
Type of ignition protection for gas Ex h IIC T4 Gb
ATEX category for dust II 2D
Type of ignition protection for dust Ex h IIIC T105°C Db
Explosion-proof ambient temperature [°C] –5 <= Ta <= +40
CE marking (see declaration of conformity) To EU Explosion Protection Directive (ATEX)

Operating and environmental conditions


Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +40
Temperature of medium [°C] –10 ... +60
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 2200
Max. negative test pulse with 1 signal [µs] 3700
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection Via F coil, to be ordered separately
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 43


Standards-based valves to ISO 5599-1, solenoid coil MSF

Technical data – Width 65 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
MFH-5/2- ... 65 48 12 30 M8 M5 117 87.3 55 12 63.5 13.5 163 145.4 72.7 64 32 109
MFH-5/2- ... -FR- ... 182 164.7

5/2-way double solenoid valves, 5/3-way valves


[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L6
JMFH-5/2- ... 65 48 12 30 M8 M5 117 87.3 55 12 – 13.5 181 145.4 72.7 64 32 109
JMFDH-5/2- ... 145.4 72.7
MFH-5/3... 184 92

44 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, solenoid coil MSF

Ordering data – Width 65 mm


Ordering data – Valves with armature tube for solenoid coil MSF1)
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 960 – 151870 MFH-5/2-D-3-C
ATEX category 535956 MFH-5/2-D-3-C-EX
a page 43
Pneumatic spring reset External 960 – 151032 MFH-5/2-D-3-S-C
ATEX category 535959 MFH-5/2-D-3-S-C-EX
a page 43
Mechanical spring reset Internal 960 – 151711 MFH-5/2-D-3-FR-C
ATEX category 535962 MFH-5/2-D-3-FR-C-EX
a page 43

5/2-way valve, double solenoid


– Internal 1060 – 151871 JMFH-5/2-D-3-C
ATEX category 535965 JMFH-5/2-D-3-C-EX
a page 43
– External 1060 – 151033 JMFH-5/2-D-3-S-C
ATEX category 535968 JMFH-5/2-D-3-S-C-EX
a page 43
With dominant signal at Internal 1060 – 151872 JMFDH-5/2-D-3-C
14 ATEX category 536073 JMFDH-5/2-D-3-C-EX
a page 43

5/3-way valve
Normally closed, Internal 1040 – 151873 MFH-5/3G-D-3-C
Mechanical spring reset ATEX category 535971 MFH-5/3G-D-3-C-EX
a page 43
Normally closed, External 1040 – 151034 MFH-5/3G-D-3-S-C
Mechanical spring reset ATEX category 535974 MFH-5/3G-D-3-S-C-EX
a page 43
Normally exhausted, Internal 1040 – 151874 MFH-5/3E-D-3-C
Mechanical spring reset ATEX category 535977 MFH-5/3E-D-3-C-EX
a page 43
Normally exhausted, External 1040 – 151035 MFH-5/3E-D-3-S-C
Mechanical spring reset ATEX category 535980 MFH-5/3E-D-3-S-C-EX
a page 43
Normally open, Internal 1040 – 151875 MFH-5/3B-D-3-C
Mechanical spring reset ATEX category 535983 MFH-5/3B-D-3-C-EX
a page 43
Normally open, External 1040 – 151036 MFH-5/3B-D-3-S-C
Mechanical spring reset ATEX category 535986 MFH-5/3B-D-3-S-C-EX
a page 43

1) Solenoid coils a page 129

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 45


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Technical data – Width 42 mm

-M- Flow rate


Up to 1300 l/min

-P- Voltage
24 V DC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Exhaust function Flow control, external or via vertically stacked throttle plate
Manual override Non-detenting, detenting
Type of mounting On sub-base
Mounting position Any
Nominal size [mm] 11
Overlap Positive overlap
Width [mm] 42
Grid dimension [mm] 43
Pneumatic connections Sub-base size 1 to ISO 5599-1
Conforms to standard ISO 5599-1
Certification c UL us – Recognized (OL)

Flow rates
Valve function 2/2-way valve 3/2-way valve 5/2-way valve 5/3-way valve
Standard nominal flow rate [l/min] 1300 1100 1300 1300
Valve 1600 1600 2000 1900
Valve on individual sub-base 1400 1200 1400 1400
Valve pneumatically linked 1300 1100 1300 1400

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
2x 2/2-way valve VSVA-B-T22... 20 38 – –
2x 3/2-way valve VSVA-B-T32... 20 38 – –
2x 3/2-way valve, reversible VSVA-B-T32... 34 28 – –
5/2-way valve, single solenoid VSVA-B-M52-A... 27 45 – –
VSVA-B-M52-M... 22 60 – –
5/2-way valve, double solenoid VSVA-B-B52... – – 16 –
VSVA-B-D52... – – – 19
5/3-way valve VSVA-B-P53... 22 65 – –

46 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Technical data – Width 42 mm


Operating and environmental conditions
Valve function 2x 2/2-way valve 2x 3/2-way valve 2x 3/2-way valve, 5/2-way valve 5/3-way valve
reversible
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [MPa] 0.3 ... 1 0.3 ... 1 – 0.3 ... 1 0.3 ... 1
[bar] 3 ... 10 3 ... 10 – 3 ... 10 3 ... 10
External pilot air [MPa] 0.3 ... 1 0.3 ... 1 –0.09 ... +1 –0.09 ... +1.6 –0.09 ... +1.6
supply [bar] 3 ... 10 3 ... 10 –0.9 ... +10 –0.9 ... +16 –0.9 ... +16
Pilot pressure [MPa] 0.3 ... 1
[bar] 3 ... 10
Ambient temperature [°C] –5 ... +50
Relative humidity [%] 0 ... 90
*

Safety characteristics
Valve function 2x 3/2-way valve 5/2-way valve 5/2-way valve, with 5/3-way valve
dominant signal at 14
Max. positive test pulse with 0 signal [µs] 1600 1400 1600 1400
Max. negative test pulse with 1 signal [µs] 1100 900 1100 900
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6

Electrical data
Valve function 2x 2/2-way valve 2x 3/2-way valve 5/2-way valve 5/3-way valve
Electrical connection Central plug, round design M12x1, 3-pin
Signal status indication LED
Characteristic coil data Voltage [V DC] 24
Power [W] 1.3 1.3 1.6 1.6
Permissible voltage fluctuations [%] ±10
Duty cycle [%] 100
Degree of protection to EN 60529 IP65, NEMA4 (in combination with a plug socket)

Materials
Housing PA
Seals NBR, FPM
Screws Galvanised steel
Note on materials RoHS-compliant

Product weight
2x 2/2-way valve [g] 442
2x 3/2-way valve [g] 442
5/2-way valve, single solenoid [g] 426
5/2-way valve, double solenoid [g] 439
5/3-way valve [g] 456

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 47


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Technical data – Width 42 mm


Pilot pressure p12/14 as a function of working pressure p1
2x 2/2-way valve and 2x 3/2-way valve 5/2-way valve and 5/3-way valve, external pilot air supply

Protective circuit
Each VSVA solenoid coil is provided
with a spark arresting protective circuit
and protected against polarity reversal.
24 V DC version M12x1 – Pin allocation on the valve
2 Signal (+) Solenoid 12
3 com (–)
4 Signal (+) Solenoid 14

Dimensions  Download CAD data a www.festo.com

[1] Plug, 3-pin [3] Captive screws M5x48 [4] Slot for inscription label [5] LED
[2] Manual override

Type B1 B2 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5
VSVA-B -...-D1-1R5L 42 28 M5 58.3 48 0.25 46.6 55.3 137.8 32 36 18 69.3

48 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Ordering data – Width 42 mm


q  Core Range
Ordering data 
Circuit symbol Description Direction of flow Pilot air Part No. Type
supply
5/2-way valve, single solenoid
Pneumatic spring reset Not reversible Internal q 561362 VSVA-B-M52-AD-D1-1R5L

Mechanical spring reset Not reversible Internal q 561363 VSVA-B-M52-MD-D1-1R5L

5/2-way valve, double solenoid


Dominance at 1st signal Not reversible Internal q 561364 VSVA-B-B52-D-D1-1R5L

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 49


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Ordering data – Width 42 mm


Ordering data
Circuit symbol Description Direction of flow Pilot air Part No. Type
supply
2x 2/2-way valve
2x normally closed, Not reversible Internal Order via online configurator
Pneumatic spring reset a Internet: vsva

2x normally closed, Not reversible External


Pneumatic spring reset

2x normally closed, Reversible Internal


Vacuum operation possible at 3 and 5,
Pneumatic spring reset

2x 3/2-way valve
2x normally closed, Not reversible Internal 561359 VSVA-B-T32C-AD-D1-1R5L
Pneumatic spring reset

2x normally closed, Not reversible External 561369 VSVA-B-T32C-AZD-D1-1R5L


Pneumatic spring reset

2x normally open, Not reversible Internal 561360 VSVA-B-T32U-AD-D1-1R5L


Pneumatic spring reset

2x normally open, Not reversible External 561370 VSVA-B-T32U-AZD-D1-1R5L


Pneumatic spring reset

1x normally closed, Not reversible Internal 561361 VSVA-B-T32H-AD-D1-1R5L


1x normally open,
Pneumatic spring reset

1x normally closed, Not reversible External 561371 VSVA-B-T32H-AZD-D1-1R5L


1x normally open,
Pneumatic spring reset

2x 3/2-way valve, reversible


2x normally closed, Reversible External Order via online configurator
Pneumatic spring reset a Internet: vsva

2x normally open, Reversible External


Pneumatic spring reset

1x normally closed, Reversible External


1x normally open,
Pneumatic spring reset

50 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Ordering data – Width 42 mm


Ordering data
Circuit symbol Description Direction of flow Pilot air Part No. Type
supply
5/2-way valve, single solenoid
Pneumatic spring reset Reversible External 561372 VSVA-B-M52-AZD-D1-1R5L

Mechanical spring reset Reversible External 561373 VSVA-B-M52-MZD-D1-1R5L

5/2-way valve, double solenoid


Dominance at 1st signal Reversible External 561374 VSVA-B-B52-ZD-D1-1R5L

With dominant signal at 14 Not reversible Internal 561365 VSVA-B-D52-D-D1-1R5L

With dominant signal at 14 Reversible External 561375 VSVA-B-D52-ZD-D1-1R5L

5/3-way valve
Normally closed, Not reversible Internal 561366 VSVA-B-P53C-D-D1-1R5L
Mechanical spring reset

Normally closed, Reversible External 561376 VSVA-B-P53C-ZD-D1-1R5L


Mechanical spring reset

Normally open, Not reversible Internal 561368 VSVA-B-P53U-D-D1-1R5L


Mechanical spring reset

Normally open, Reversible External 561378 VSVA-B-P53U-ZD-D1-1R5L


Mechanical spring reset

Normally exhausted, Not reversible Internal 561367 VSVA-B-P53E-D-D1-1R5L


Mechanical spring reset

Normally exhausted, Reversible External 561377 VSVA-B-P53E-ZD-D1-1R5L


Mechanical spring reset

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 51


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Technical data – Width 52 mm

-M- Flow rate


Up to 2800 l/min

-P- Voltage
24 V DC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Exhaust function Flow control, external or via vertically stacked throttle plate
Manual override Non-detenting, detenting
Type of mounting On sub-base
Mounting position Any
Nominal size [mm] 15
Overlap Positive overlap
Width [mm] 52
Grid dimension [mm] 59
Pneumatic connections Sub-base size 2 to ISO 5599-1
Conforms to standard ISO 5599-1
Certification c CSA us (OL)
c UL us – Recognized (OL)
C-Tick

Flow rates
Valve function 2/2-way valve 3/2-way valve 5/2-way valve 5/3-way valve
Standard nominal flow rate [l/min] 2800 2200 2800 2700
Valve 4000 3000 4000 3600
Valve on individual sub-base 2400 2000 2400 2300
Valve pneumatically linked 2800 2200 2800 2700

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
2x 2/2-way valve VSVA-B-T22... 14 35 – –
2x 3/2-way valve VSVA-B-T32... 20 35 – –
2x 3/2-way valve, reversible VSVA-B-T32... 30 30 – –
5/2-way valve, single solenoid VSVA-B-M52-A... 40 45 – –
VSVA-B-M52-M... 20 60 – –
5/2-way valve, double solenoid VSVA-B-B52... – – 18 –
VSVA-B-D52... – – – 18
5/3-way valve VSVA-B-P53... 23 60 – –

52 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Technical data – Width 52 mm


Operating and environmental conditions
Valve function 2x 2/2-way valve 2x 3/2-way valve 2x 3/2-way valve, 5/2-way valve 5/3-way valve
reversible
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [MPa] 0.3 ... 1 0.3 ... 1 – 0.3 ... 1 0.3 ... 1
[bar] 3 ... 10 3 ... 10 – 3 ... 10 3 ... 10
External pilot air [MPa] 0.3 ... 1 0.3 ... 1 –0.09 ... +1 –0.09 ... +1.6 –0.09 ... +1.6
supply [bar] 3 ... 10 3 ... 10 –0.9 ... +10 –0.9 ... +16 –0.9 ... +16
Pilot pressure [MPa] 0.3 ... 1
[bar] 3 ... 10
Ambient temperature [°C] –5 ... +50
Relative humidity [%] 0 ... 90
*

Safety characteristics
CE marking (see declaration of conformity) To EU EMC Directive1)
KC mark KC EMC
Max. positive test pulse with 0 signal [µs] 1000
Max. negative test pulse with 1 signal [µs] 3500
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6

1) For information about the area of use, see the EC declaration of conformity at: www.festo.com/catalogue/... d Support/Downloads.
If the devices are subject to usage restrictions in residential, commercial or light-industrial environments, further measures for the reduction of the emitted interference may be necessary.

Electrical data
Electrical connection Central plug, round design M12x1, 3-pin
Signal status indication LED
Characteristic coil data Voltage [V DC] 24
Power [W] 4.6
Permissible voltage fluctuations [%] ±10
Nominal pick-up current per solenoid coil [mA] 165
Nominal current with current reduction [mA] 35
Time until current reduction [ms] 30
Duty cycle [%] 100
Degree of protection to EN 60529 IP65, NEMA4 (in combination with a plug socket)

Materials
Housing Die-cast aluminium, PA
Seals HNBR, NBR, FPM
Screws Galvanised steel
Note on materials RoHS-compliant

Product weight
2x 2/2-way valve [g] 740
2x 3/2-way valve [g] 740
5/2-way valve, single solenoid [g] 702
5/2-way valve, double solenoid [g] 732
5/3-way valve [g] 780

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 53


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Technical data – Width 52 mm


Pilot pressure p12/14 as a function of working pressure p1
2x 2/2-way valve and 2x 3/2-way valve 5/2-way valve and 5/3-way valve, external pilot air supply

Protective circuit
Each VSVA solenoid coil is provided
with a spark arresting protective circuit
and protected against polarity reversal.
24 V DC version M12x1 – Pin allocation on the valve
2 Signal (+) Solenoid 12
3 com (–)
1
4 Signal (+) Solenoid 14

[1] Holding current reduction

 Dimensions Download CAD data a www.festo.com

[1] Plug, 3-pin [3] Captive screws M6x60 [4] Slot for inscription label [5] LED
[2] Manual override

Type B1 B2 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5
VSVA-B -...-D2-1R5L 52 38 M6 58.3 60 0.3 56.4 55.3 160.7 40.9 48 24 64.3

54 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Ordering data – Width 52 mm


 Ordering data
Circuit symbol Description Direction of flow Pilot air Part No. Type
supply
2x 2/2-way valve
2x normally closed, Not reversible Internal Order via online configurator
Pneumatic spring reset a Internet: vsva

2x normally closed, Not reversible External


Pneumatic spring reset

2x 3/2-way valve
2x normally closed, Not reversible Internal 566990 VSVA-B-T32C-AD-D2-1R5L
Pneumatic spring reset

2x normally closed, Not reversible External 567000 VSVA-B-T32C-AZD-D2-1R5L


Pneumatic spring reset

2x normally open, Not reversible Internal 566991 VSVA-B-T32U-AD-D2-1R5L


Pneumatic spring reset

2x normally open, Not reversible External 567001 VSVA-B-T32U-AZD-D2-1R5L


Pneumatic spring reset

1x normally closed, Not reversible Internal 566992 VSVA-B-T32H-AD-D2-1R5L


1x normally open,
Pneumatic spring reset

1x normally closed, Not reversible External 567002 VSVA-B-T32H-AZD-D2-1R5L


1x normally open,
Pneumatic spring reset

2x 3/2-way valve, reversible


2x normally closed, Reversible External Order via online configurator
Pneumatic spring reset a Internet: vsva

2x normally open, Reversible External


Pneumatic spring reset

1x normally closed, Reversible External


1x normally open,
Pneumatic spring reset

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 55


Standards-based valves to ISO 5599-1, central plug M12, 3-pin

Ordering data – Width 52 mm


Ordering data
Circuit symbol Description Direction of flow Pilot air Part No. Type
supply
5/2-way valve, single solenoid
Pneumatic spring reset Not reversible Internal 566993 VSVA-B-M52-AD-D2-1R5L

Pneumatic spring reset Reversible External 567003 VSVA-B-M52-AZD-D2-1R5L

Mechanical spring reset Not reversible Internal 566994 VSVA-B-M52-MD-D2-1R5L

Mechanical spring reset Reversible External 567004 VSVA-B-M52-MZD-D2-1R5L

5/2-way valve, double solenoid


Dominance at 1st signal Not reversible Internal 566995 VSVA-B-B52-D-D2-1R5L

Dominance at 1st signal Reversible External 567005 VSVA-B-B52-ZD-D2-1R5L

With dominant signal at 14 Not reversible Internal 566996 VSVA-B-D52-D-D2-1R5L

With dominant signal at 14 Reversible External 567006 VSVA-B-D52-ZD-D2-1R5L

5/3-way valve
Normally closed, Not reversible Internal 566997 VSVA-B-P53C-D-D2-1R5L
Mechanical spring reset

Normally closed, Reversible External 567007 VSVA-B-P53C-ZD-D2-1R5L


Mechanical spring reset

Normally open, Not reversible Internal 566999 VSVA-B-P53U-D-D2-1R5L


Mechanical spring reset

Normally open, Reversible External 567009 VSVA-B-P53U-ZD-D2-1R5L


Mechanical spring reset

Normally exhausted, Not reversible Internal 566998 VSVA-B-P53E-D-D2-1R5L


Mechanical spring reset

Normally exhausted, Reversible External 567008 VSVA-B-P53E-ZD-D2-1R5L


Mechanical spring reset

56 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 4-pin

Technical data – Width 65 mm

-M- Flow rate


Up to 4600 l/min

-P- Voltage
24 V DC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow Not reversible
Exhaust function Can be throttled
Manual override Non-detenting
Type of mounting Via through-hole
Mounting position Any
Nominal size [mm] 14.5
Width [mm] 65
Grid dimension [mm] 71
Pneumatic connections Sub-base size 3 to ISO 5599-1
Conforms to standard ISO 5599-1

Flow rates
Valve function 5/2-way valve 5/3-way valve
Normally closed Normally exhausted Normally open
Standard nominal flow rate [l/min] 4500 4100 4600 4000

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MEBH-5/2-... 59 87 – –
MEBH-5/2-D-1-ZSR-FR-... 28 109 – –
5/2-way valve, double solenoid JMEBH-... – – 16 –
JMEBDH-... – – – 20
5/3-way valve MEBH-5/3G-... 38 130 – –
MEBH-5/3E-... 38 130 – –
MEBH-5/3B-... 38 130 – –

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 57


Standards-based valves to ISO 5599-1, central plug M12, 4-pin

Technical data – Width 65 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –5 ... +50
Temperature of medium [°C] –5 ... +50
Relative humidity [%] 0 ... 90
*

Electrical data
Electrical connection Central plug, round design M12x1, 4-pin
Characteristic coil data Voltage [V DC] 24
Power [W] 2.5
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals NBR

58 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, central plug M12, 4-pin

Technical data – Width 65 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[1] Plug socket mounting
adjustable by 3x30°
[2] Manual override
[3] Captive retaining screws
[5] LED indicator
[6] Angled plug socket SIE-WD-TR
d page 131

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
MEBH-5/2 ... 65 48 12 17.5 M8 M12 130 97.8 55 12 93.1 158.7 145.4 72.7 64 32 86
MEBH-5/2- ... -FR-C 178 164.7

5/2-way double solenoid valves, 5/3-way valves


[1] Plug socket mounting
adjustable by 3x30°
[2] Manual override
[3] Captive retaining screws
[5] LED indicator
[6] Angled plug socket SIE-WD-TR
d page 131

Type B1 B2 B3 B4 D1 D2 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
JMEBH-5/2- ... 65 48 12 17.5 M8 M12 130 97.8 55 12 93.1 171.9 145.4 72.7 64 32 86
JMEBDH-5/2- ... 145.4 72.7
MEBH-5/3... 184 92

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 59


Standards-based valves to ISO 5599-1, central plug M12, 4-pin

Ordering data – Width 65 mm


Central plug M12 – Pin allocation
5/2-way valve, single solenoid 5/2-way double solenoid valve and 5/3-way valve
1 Unused 1 Unused
2 Unused 2 Signal (+) Solenoid 12
3 com (–) 3 com (–)
4 Signal (+) Solenoid 14 4 Signal (+) Solenoid 14

Ordering data 
Circuit symbol Description Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset Internal 1000 184507 MEBH-5/2-D-3-ZSR-C

Mechanical spring reset Internal 1000 184508 MEBH-5/2-D-3-ZSR-FR-C

5/2-way valve, double solenoid


– Internal 1080 184509 JMEBH-5/2-D-3-ZSR-C

With dominant signal at 14 Internal 1080 184510 JMEBDH-5/2-D-3-ZSR-C

5/3-way valve
Normally closed, Internal 1120 184512 MEBH-5/3G-D-3-ZSR-C
Mechanical spring reset

Normally exhausted, Internal 1120 184511 MEBH-5/3E-D-3-ZSR-C


Mechanical spring reset

Normally open, Internal 1120 184513 MEBH-5/3B-D-3-ZSR-C


Mechanical spring reset

60 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 42 mm

-M- Flow rate


Up to 1200 l/min

-P- Voltage
24 V DC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow With external pilot air supply Reversible
With internal pilot air supply Not reversible
Exhaust function Can be throttled
Manual override Non-detenting
Type of mounting On sub-base via through-hole
Mounting position Any
Nominal size [mm] 8
Overlap Positive overlap
Width [mm] 42
Grid dimension [mm] 43
Pneumatic connections Sub-base size 1 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1

Flow rates
Standard nominal flow rate [l/min] 1200

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MDH-5/2-... 25 36 – –
MDH-5/2-...-FR-... 20 42 – –
5/2-way valve, double solenoid JMDH-... – – 18 –
JMDDH-... – – 18 18
5/3-way valve MDH-5/3G-... 25 55 – –
MDH-5/3E-... 25 55 – –
MDH-5/3B-... 25 55 – –

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 61


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 42 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] –0.9 ... +16 –0.9 ... +16
Pilot pressure Internal pilot air supply [bar] 2 ... 10 3 ... 10
External pilot air supply [bar] 3 ... 10 3 ... 10
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +50
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 3800
Max. negative test pulse with 1 signal [µs] 4900
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection M12x1
Characteristic coil data Voltage [V DC] 24
Power [W] 2.7
Permissible voltage fluctuations [%] ±10
Duty cycle [%] 100
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR

62 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 42 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[1] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label
[5] LED indicator
[6] Device plug M12x1
2-pin coil to VDMA
4-pin coil to Desina

Type B1 B2 B3 B4 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
MDH-5/2 ... 42 28 6 30 M5 87.2 77.2 38 9 46.5 121.8 87.6 43.8 36 18 –
MDH-5/2- ... -FR-... 132.2 98

5/2-way double solenoid valves, 5/3-way valves


[1] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override
[2] Manual override
[3] Captive retaining screws
[5] LED indicator
[6] Device plug M12x1
2-pin coil to VDMA
4-pin coil to Desina

Type B1 B2 B3 B4 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
JMDH-5/2- ... 42 28 6 30 M5 87.2 77.2 38 9 – 148 87.6 43.8 36 18 108.5
JMDDH-5/2- ... 87.6 43.8
MDH-5/3... 108.4 54.3

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 63


Standards-based valves to ISO 5599-1, individual plug M12x1

Ordering data – Width 42 mm


Pin allocation
M12 plug – 2-pin to VDMA M12 plug – 4-pin to Desina
1 Unused 1 Connected to 2
2 Unused 2 Connected to 1
3 com (–) 3 com (–)
4 Signal (+) 4 Signal (+)

Ordering data – Solenoid valves


Circuit symbol Description Coil Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset 2-pin to VDMA Internal 420 197125 MDH-5/2-D-1-M12-C
4-pin to Internal 420 540803 MDH-5/2-D-1-M12D-C
Desina
Pneumatic spring reset 2-pin to VDMA External 420 533332 MDH-5/2-D-1-S-M12-C
4-pin to External 420 540810 MDH-5/2-D-1-S-M12D-C
Desina
Mechanical spring reset 2-pin to VDMA Internal 420 533010 MDH-5/2-D-1-FR-M12-C
4-pin to Internal 420 540804 MDH-5/2-D-1-FR-M12D-C
Desina
Mechanical spring reset 2-pin to VDMA External 420 533761 MDH-5/2-D-1-S-FR-M12-C
4-pin to External 420 540811 MDH-5/2-D-1-S-FR-M12D-C
Desina

5/2-way valve, double solenoid


– 2-pin to VDMA Internal 550 532687 JMDH-5/2-D-1-M12-C
4-pin to Internal 550 540809 JMDH-5/2-D-1-M12D-C
Desina
With dominant signal at 14 2-pin to VDMA Internal 550 539079 JMDDH-5/2-D-1-M12-C
4-pin to Internal 550 540808 JMDDH-5/2-D-1-M12D-C
Desina

5/3-way valve
Normally closed, mechanical 2-pin to VDMA Internal 580 525307 MDH-5/3G-D-1-M12-C
spring reset 4-pin to Internal 580 540806 MDH-5/3G-D-1-M12D-C
Desina
Normally exhausted, 2-pin to VDMA Internal 580 197126 MDH-5/3E-D-1-M12-C
Mechanical spring reset 4-pin to Internal 580 540805 MDH-5/3E-D-1-M12D-C
Desina
Normally open, 2-pin to VDMA Internal 580 533005 MDH-5/3B-D-1-M12-C
Mechanical spring reset 4-pin to Internal 580 540807 MDH-5/3B-D-1-M12D-C
Desina

64 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 52 mm

-M- Flow rate


Up to 2300 l/min

-P- Voltage
24 V DC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow Not reversible
Exhaust function Can be throttled
Manual override Non-detenting
Type of mounting On sub-base, with through-hole and screw
Mounting position Any
Nominal size [mm] 11.5
Overlap Positive overlap
Width [mm] 52
Grid dimension [mm] 56
Pneumatic connections Sub-base size 2 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1

Flow rates
Standard nominal flow rate [l/min] 2300

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MDH-5/2-... 45 60 – –
MDH-5/2-...-FR-... 25 60 – –
5/2-way valve, double solenoid JMDH-... – – 20 –
JMDDH-... – – 20 20
5/3-way valve MDH-5/3G-... 35 70 – –
MDH-5/3E-... 35 70 – –
MDH-5/3B-... 35 70 – –

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 65


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 52 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +50
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 3800
Max. negative test pulse with 1 signal [µs] 4900
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection M12x1
Characteristic coil data Voltage [V DC] 24
Power [W] 2.7
Permissible voltage fluctuations [%] ±10
Duty cycle [%] 100
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

66 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 52 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[1] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label
[5] LED indicator
[6] Device plug M12x1
2-pin coil to VDMA
4-pin coil to Desina

Type B1 B2 B3 B4 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
MDH-5/2 ... 54 38 9 30 M6 97.2 87.2 48 9.5 56.5 144.6 123.4 61.7 48 24 –
MDH-5/2- ... -FR-... 161.9 140.6

5/2-way double solenoid valves, 5/3-way valves


[1] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override
[2] Manual override
[3] Captive retaining screws
[5] LED indicator
[6] Device plug M12x1
2-pin coil to VDMA
4-pin coil to Desina

Type B1 B2 B3 B4 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
JMDH-5/2- ... 54 38 9 30 M6 97.2 87.2 48 9.5 – 165.8 123.4 61.7 48 24 126.3
JMDDH-5/2- ... 123.4 61.7
MDH-5/3... 158 79

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 67


Standards-based valves to ISO 5599-1, individual plug M12x1

Ordering data – Width 52 mm


Pin allocation
M12 plug – 2-pin to VDMA M12 plug – 4-pin to Desina
1 Unused 1 Connected to 2
2 Unused 2 Connected to 1
3 com (–) 3 com (–)
4 Signal (+) 4 Signal (+)

Ordering data 
Circuit symbol Description Coil Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset 2-pin to VDMA Internal 810 533008 MDH-5/2-D-2-M12-C
4-pin to Internal 810 540812 MDH-5/2-D-2-M12D-C
Desina
Mechanical spring reset 2-pin to VDMA Internal 810 533011 MDH-5/2-D-2-FR-M12-C
4-pin to Internal 810 540813 MDH-5/2-D-2-FR-M12D-C
Desina

5/2-way valve, double solenoid


– 2-pin to VDMA Internal 940 533013 JMDH-5/2-D-2-M12-C
4-pin to Internal 940 540818 JMDH-5/2-D-2-M12D-C
Desina
With dominant signal at 14 2-pin to VDMA Internal 940 539077 JMDDH-5/2-D-2-M12-C
4-pin to Internal 940 540817 JMDDH-5/2-D-2-M12D-C
Desina

5/3-way valve
Normally closed, mechanical 2-pin to VDMA Internal 1000 539078 MDH-5/3G-D-2-M12-C
spring reset 4-pin to Internal 1000 540815 MDH-5/3G-D-2-M12D-C
Desina
Normally exhausted, 2-pin to VDMA Internal 1000 533016 MDH-5/3E-D-2-M12-C
Mechanical spring reset 4-pin to Internal 1000 540814 MDH-5/3E-D-2-M12D-C
Desina
Normally open, 2-pin to VDMA Internal 1000 533006 MDH-5/3B-D-2-M12-C
Mechanical spring reset 4-pin to Internal 1000 540816 MDH-5/3B-D-2-M12D-C
Desina

68 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 65 mm

-M- Flow rate


Up to 4500 l/min

-P- Voltage
24 V DC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow Not reversible
Exhaust function Can be throttled
Manual override Non-detenting
Type of mounting On sub-base, with through-hole and screw
Mounting position Any
Nominal size [mm] 14.5
Overlap Positive overlap
Width [mm] 65
Grid dimension [mm] 71
Pneumatic connections Sub-base size 3 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1

Flow rates
Valve function 5/2-way valve 5/3-way valve
Normally closed Normally exhausted Normally open
Standard nominal flow rate [l/min] 4500 4100 4600 4000

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid MDH-5/2-... 54 57 – –
MDH-5/2-...-FR-... 28 68 – –
5/2-way valve, double solenoid JMDH-... – – 21 –
JMDDH-... – – 23 23
5/3-way valve MDH-5/3G-... 35 79 – –
MDH-5/3E-... 36 84 – –
MDH-5/3B-... 36 84 – –

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 69


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 65 mm


Operating and environmental conditions
Reset method Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 2 ... 10 3 ... 10
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +50
*

Safety characteristics
Max. positive test pulse with 0 signal [µs] 3800
Max. negative test pulse with 1 signal [µs] 4900
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Electrical data
Electrical connection M12x1
Characteristic coil data Voltage [V DC] 24
Power [W] 2.7
Permissible voltage fluctuations [%] ±10
Duty cycle [%] 100
Degree of protection to EN 60529 IP65

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

70 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual plug M12x1

Technical data – Width 65 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[1] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override
[2] Manual override
[3] Captive retaining screws
[4] Slot for inscription label
[5] LED indicator
[6] Device plug M12x1
2-pin coil to VDMA
4-pin coil to Desina

Type B1 B2 B3 B4 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
MDH-5/2 ... 65 48 12 30 M8 104.2 94.2 55 12 62.5 165.9 145.4 72.7 64 32 –
MDH-5/2- ... -FR-... 182.5 140.6

5/2-way double solenoid valves, 5/3-way valves


[1] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override
[2] Manual override
[3] Captive retaining screws
[5] LED indicator
[6] Device plug M12x1
2-pin coil to VDMA
4-pin coil to Desina

Type B1 B2 B3 B4 D1 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5 L6
JMDH-5/2- ... 65 48 12 30 M8 104.2 94.2 55 12 – 186.4 145.4 72.7 64 32 146.9
JMDDH-5/2- ... 145.4 72.7
MDH-5/3... 184 92

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 71


Standards-based valves to ISO 5599-1, individual plug M12x1

Ordering data – Width 65 mm


Pin allocation
M12 plug – 2-pin to VDMA M12 plug – 4-pin to Desina
1 Unused 1 Connected to 2
2 Unused 2 Connected to 1
3 com (–) 3 com (–)
4 Signal (+) 4 Signal (+)

Ordering data 
Circuit symbol Description Coil Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset 2-pin to VDMA Internal 1000 533009 MDH-5/2-D-3-M12-C
4-pin to Internal 1000 540819 MDH-5/2-D-3-M12D-C
Desina
Mechanical spring reset 2-pin to VDMA Internal 1000 533012 MDH-5/2-D-3-FR-M12-C
4-pin to Internal 1000 540820 MDH-5/2-D-3-FR-M12D-C
Desina

5/2-way valve, double solenoid


– 2-pin to VDMA Internal 1100 533015 JMDH-5/2-D-3-M12-C
4-pin to Internal 1100 540825 JMDH-5/2-D-3-M12D-C
Desina
With dominant signal at 14 2-pin to VDMA Internal 1100 539081 JMDDH-5/2-D-3-M12-C
4-pin to Internal 1100 540824 JMDDH-5/2-D-3-M12D-C
Desina

5/3-way valve
Normally closed, mechanical 2-pin to VDMA Internal 1120 539080 MDH-5/3G-D-3-M12-C
spring reset 4-pin to Internal 1120 540822 MDH-5/3G-D-3-M12D-C
Desina
Normally exhausted, 2-pin to VDMA Internal 1120 533017 MDH-5/3E-D-3-M12-C
Mechanical spring reset 4-pin to Internal 1120 540821 MDH-5/3E-D-3-M12D-C
Desina
Normally open, 2-pin to VDMA Internal 1120 533007 MDH-5/3B-D-3-M12-C
Mechanical spring reset 4-pin to Internal 1120 540823 MDH-5/3B-D-3-M12D-C
Desina

72 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, square plug type A

Technical data – Width 76 mm

-M- Flow rate


Up to 6000 l/min

-P- Voltage
24 V DC
48 V AC

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Electrical
Type of control Piloted
Direction of flow Not reversible
Exhaust function Can be throttled
Manual override Non-detenting
Type of mounting On sub-base, with through-hole and screw
Mounting position Any
Nominal size [mm] 18
Overlap Positive overlap
Width [mm] 76
Grid dimension [mm] 82
Pneumatic connections Sub-base size 4 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1

Flow rates
Valve function 5/2-way valve 5/3-way valve
Standard nominal flow rate [l/min] 6000 4800

Switching times [ms]


Switching time on Switching time off Switching time changeover
5/2-way valve Single solenoid 120 160 –
Double solenoid – – 40
5/3-way valve 85 290 –

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 73


Standards-based valves to ISO 5599-1, square plug type A

Technical data – Width 76 mm


Operating and environmental conditions
Valve function 5/2-way valve, single 5/2-way valve, double 5/3-way valve
solenoid solenoid
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 3 ... 16 2 ... 16 3 ... 16
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +60
*

Safety characteristics
Type MDH-...-D-4-24DC, JMDH-...-D-4-24DC MDH-...-D-4, JMDH-...-D-4
Max. positive test pulse with 0 signal [µs] 4300 –
Max. negative test pulse with 1 signal [µs] 2100 –

Electrical data – MDH-...-24DC, JMDH-...-24DC


Direct voltage Alternating voltage
Electrical connection To DIN EN 175301-803
Characteristic coil data Voltage [V DC] 24 –
[V AC] – 48
Frequency [Hz] – 5 0/60
Power [W] 6.8 –
Pick-up power [VA] – 14.5
Holding power [VA] – 9.9
Duty cycle [%] 100
Degree of protection to EN 60529 IP65

Electrical data – Pilot valve MDH-3/2-...


Type MDH-3/2-24DC MDH-3/2-24DC/42AC MDH-3/2-110AC MDH-3/2-230AC
Electrical connection Plug, square design to EN 175301-803, type A
Characteristic coil data Voltage [V DC] 24 – – 24 – – – – 110 – –
[V AC] – 48 53 – 42 42 110 110 – 230 230
Frequency [Hz] – 50 60 – 50 60 50 60 – 50 60
Power [W] 6.8 – – 8.4 – – – – 6.3 – –
Pick-up power [VA] – 14.5 15 – 14 12 14.5 12 – 14.5 12
Holding power [VA] – 9.9 9.3 – 10 7 10.5 7.6 – 10.5 7.6
Permissible voltage fluctuations [%] ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10
Permissible frequency fluctuations [%] – – – ±10 ±10 ±10 ±10 ±10 ±10 ±10 ±10
Duty cycle [%] 100
Degree of protection to EN 60529 IP65

Materials
Housing Aluminium
Seals NBR
Note on materials RoHS-compliant

74 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, square plug type A

Technical data – Width 76 mm


Dimensions Download CAD data a www.festo.com
5/2-way valves, single solenoid
[1] Connection for plug socket with
plug pattern to EN 175301-803,
type A d page 130
[2] Manual override
[3] Captive retaining screws
[4] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override

Type B1 B2 D1 H1 H2 H3 H4 L1 L2 L3 L4 L5
MDH-5/2 ... 76 58 M8 139 110.5 74 14 182 67.5 80 40 81

5/2-way double solenoid valves, 5/3-way valves


[1] Connection for plug socket with
plug pattern to EN 175301-803,
type A d page 130
[2] Manual override
[3] Captive retaining screws
[4] Solenoid coil can be reposi-
tioned by 90° regardless of the
manual override

Type B1 B2 D1 H1 H2 H3 H4 L1 L2 L3 L4 L5
JMDH-5/2- ... 76 58 M8 139 110.5 74 14 182 135 80 40 162
MDH-5/3...

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 75


Standards-based valves to ISO 5599-1, square plug type A

Ordering data – Width 76 mm


Ordering data 
Circuit symbol Description Voltage Pilot air Weight Part No. Type
supply [g]
5/2-way valve, single solenoid
Pneumatic spring reset 24 V DC Internal 2600 12457 MDH-5/2-3/4-D-4-24DC
– Internal 2600 14544 MDH-5/2-3/4-D-41)

5/2-way valve, double solenoid


– 24 V DC Internal 2600 12458 JMDH-5/2-3/4-D-4-24DC
– Internal 2600 14545 JMDH-5/2-3/4-D-41)

5/3-way valve
Normally closed, mechanical 24 V DC Internal 2600 12459 MDH-5/3G-3/4-D-4-24DC
spring reset – Internal 2600 14546 MDH-5/3G-3/4-D-41)

Normally exhausted, 24 V DC Internal 2600 12460 MDH-5/3E-3/4-D-4-24DC


Mechanical spring reset – Internal 2600 14547 MDH-5/3E-3/4-D-41)

Usable pilot valves


Electrical connection to 24 V DC – 140 119600 MDH-3/2-24DC
EN 175301-803 type A 24 V DC/ – 140 119603 MDH-3/2-24DC/42AC
42 V AC
110 V AC – 140 119601 MDH-3/2-110AC
110 V DC/ – 140 119602 MDH-3/2-230AC
230 V AC

1) Without pilot valve. The part number of the pilot valve must be added after the type code when ordering.
Order example: 14546 MDH-5/3G-3/4-D-4-119602 (for MDH-3/2-230AC with part no. 119602)

76 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Peripherals overview
Valve on individual sub-base

3
4

1
3

1
2
1

Individual components
Type Brief description a Page/Internet
[1] Push-in fitting QS-... For connecting tubing with standard O.D. qs
[2] Sub-base VABS-S1-... Lateral pneumatic connections 97
Individual sub-base NAS-... Lateral pneumatic connections 97
NAU-... Pneumatic connections underneath 100
[3] Silencer U-... For mounting in exhaust ports silencer
[4] Pneumatic valve VL-... Port pattern to ISO 5599-1 80
J-... Port pattern to ISO 5599-1 80
JD-... Port pattern to ISO 5599-1 80

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 77


Standards-based valves to ISO 5599-1, pneumatic valves

Peripherals overview
Manifold assembly

2
3

1
8
4
10
9 5
4

6 2 3
5

4
2
2
3 4
2
1

Individual components
Type Brief description a Page/Internet
[1] End plates VABE-S1-... For sealing the manifold sub-bases 109
[2] Push-in fitting QS-... For connecting tubing with standard O.D. qs
[3] Silencer U-... For mounting in exhaust ports silencer
[4] Manifold sub-base VABV-S1-... With ports 2 and 4 102
[5] Duct separation VABD-S1-1-... For sealing ducts 1, 3, 5, 12 and 14 between end plate and manifold 113
sub-base, e.g. to create pressure zones
[6] Supply plate VABF-S1-1-... With ports for air supply 1 and exhausts 3 and 5 104
[7] Pneumatic valve VL-... Port pattern to ISO 5599-1 80
J-... Port pattern to ISO 5599-1 80
JD-... Port pattern to ISO 5599-1 80
[8] Cover plate NDV-... For sealing unused manifold sub-bases 112
[9] Throttle plate VABF-S1-...-F1B1-C Controls the flow of exhaust air in ducts 3 and 5 116
GRO-ZP-... Controls the flow of exhaust air in ducts 3 and 5 116
[10] Regulator plate VABF-S1-...-R... Pressure regulator for manually setting a particular pressure in the regulated 123
port upstream or downstream of the valve
LR-ZP-... Pressure regulator for manually setting a particular pressure in the regulated 123
port upstream or downstream of the valve

78 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Peripherals overview
Manifold assembly

12 11
8
9
2 2
8

10

2
9

3
4
2 4 1

5 6

2 8
8

Individual components
Type Brief description a Page/Internet
[1] End plate kit NEV-... For sealing the manifold sub-bases 108
[2] Push-in fitting QS-... For connecting tubing with standard O.D. qs
[3] 90° connection plate NAW-... For routing ports 2 and 4 to the front 107
[4] Manifold sub-base NAV-... With ports 2 and 4 underneath 102
[5] Isolating disc NSC-... For sealing ducts 1, 3, 5 between end plate and manifold sub-base, e.g. to 112
create pressure zones
[6] Intermediate plate NZV-... For connecting manifold sub-bases of different sizes 114
[7] Manifold sub-base with 90° NAVW-... With ports 2 and 4 either underneath or to the front 107
connections
[8] Silencer U-... For mounting in exhaust ports silencer
[9] Pneumatic valve VL-... Port pattern to ISO 5599-1 80
J-... Port pattern to ISO 5599-1 80
JD-... Port pattern to ISO 5599-1 80
[10] Cover plate NDV-... For sealing unused manifold sub-bases 112
[11] Throttle plate VABF-S1-...-F1B1-C Controls the flow of exhaust air in ducts 3 and 5 116
GRO-ZP-... Controls the flow of exhaust air in ducts 3 and 5 116
[12] Regulator plate VABF-S1-...-R... Pressure regulator for manually setting a particular pressure in the regulated 123
port upstream or downstream of the valve
LR-ZP-... Pressure regulator for manually setting a particular pressure in the regulated 123
port upstream or downstream of the valve

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 79


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 42 mm

-M- Flow rate


1200 l/min

General technical data


Type VL- ... -C, J ... -C VL- ... -EX, J ... -EX
Design Piston spool Piston spool
Sealing principle Soft Soft
Actuation type Pneumatic Pneumatic
Type of control Direct Direct
Direction of flow Reversible Reversible
VL-5/2-D-1-C: non-reversible VL-5/2-D-1-C-EX: non-reversible
Exhaust function Can be throttled Can be throttled
Manual override None None
Type of mounting On sub-base via through-hole On sub-base via through-hole
Mounting position Any Any
Nominal size [mm] 8 8
Overlap Positive overlap Positive overlap
Width [mm] 42 42
Grid dimension [mm] 43 43
Pneumatic connections Sub-base size 1 to ISO 5599-1 Sub-base size 1 to ISO 5599-1
Noise level [dB (A)] 85 85
Conforms to standard ISO 5599-1 ISO 5599-1

Flow rates
Standard nominal flow rate [l/min] 1200

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid VL-5/2-D-1-C 9 18 – –
VL-5/2-D-1-C-EX 9 18 – –
VL-5/2-D-1-FR-C 6 23 – –
VL-5/2-D-1-FR-C-EX 6 23 – –
5/2-way valve, double solenoid J-5/2-D-1-C – – 6 –
J-5/2-D-1-C-EX – – 6 –
JD-5/2-D-1-C – – 6 4
JD-5/2-D-1-C-EX – – 6 4
5/3-way valve VL-5/3G-D-1-C 7 44 – –
VL-5/3G-D-1-C-EX 7 44 – –
VL-5/3E-D-1-C 7 45 – –
VL-5/3E-D-1-C-EX 7 45 – –
VL-5/3B-D-1-C 7 44 – –
VL-5/3B-D-1-C-EX 7 44 – –

80 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 42 mm


ATEX
Type VL- ... -EX, J ... -EX
ATEX category for gas II 2G
Type of ignition protection for gas Ex h IIC T4 Gb
ATEX category for dust II 2D
Type of ignition protection for dust Ex h IIIC T130°C Db
Explosion-proof ambient temperature [°C] –10 <= Ta <= +60
CE marking (see declaration of conformity) To EU Explosion Protection Directive (ATEX)

Operating and environmental conditions


Valve function 5/2-way valve 5/3-way valve
Single solenoid Double solenoid
Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 2 ... 16 –0.9 ... +16 –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 16 3 ... 16 2 ... 16 3 ... 16
Ambient temperature [°C] –10 ... +60
Temperature of medium [°C] –10 ... +60
*

Safety characteristics
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 81


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 42 mm


Dimensions  Download CAD data a www.festo.com
5/2-way valves, pneumatic spring reset, 5/2-way bistable valves
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/2- ... 42 28 6 M5 38 9 46.5 87.6 43.8 36 18
J-5/2- ...
JD-5/2- ...

5/2-way valves, mechanical spring reset


[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/2- ... -FR- ... 42 28 6 M5 38 9 46.5 98 43.8 36 18

82 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 42 mm


Dimensions  Download CAD data a www.festo.com
5/3-way valves
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/3... 42 28 6 M5 38 9 46.5 108.4 54.2 36 18

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 83


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 42 mm


Ordering data 
Circuit symbol Description Weight Part No. Type
[g]
5/2-way valve, single solenoid
Pneumatic spring reset – 290 151009 VL-5/2-D-1-C
ATEX category a page 81 290 536007 VL-5/2-D-1-C-EX

Mechanical spring reset – 290 151014 VL-5/2-D-1-FR-C


ATEX category a­page  81 290 536010 VL-5/2-D-1-FR-C-EX

5/2-way valve, double solenoid


– – 290 151007 J-5/2-D-1-C
ATEX category apage 81 290 536013 J-5/2-D-1-C-EX

With dominant signal at 14 UL – Recognized (OL) 290 151008 JD-5/2-D-1-C


ATEX category apage 81 290 536016 JD-5/2-D-1-C-EX

5/3-way valve
Normally closed UL – Recognized (OL) 320 151010 VL-5/3G-D-1-C
Mechanical spring reset ATEX category apage 81 320 536019 VL-5/3G-D-1-C-EX

Normally exhausted – 320 151011 VL-5/3E-D-1-C


Mechanical spring reset ATEX category apage 81 320 536022 VL-5/3E-D-1-C-EX

Normally pressurised UL – Recognized (OL) 320 151012 VL-5/3B-D-1-C


Mechanical spring reset ATEX category apage 81 320 536025 VL-5/3B-D-1-C-EX

84 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 52 mm

-M- Flow rate


2300 l/min

General technical data


Type VL- ... -C, J ... -C VL- ... -EX, J ... -EX
Design Piston spool Piston spool
Sealing principle Soft Soft
Actuation type Pneumatic Pneumatic
Type of control Direct Direct
Direction of flow Reversible Reversible
VL-5/2-D-2-C: non-reversible VL-5/2-D-2-C-EX: non-reversible
Exhaust function Can be throttled Can be throttled
Manual override None None
Type of mounting On sub-base, with through-hole and screw On sub-base, with through-hole and screw
Mounting position Any Any
Nominal size [mm] 11.5 11.5
Overlap Positive overlap Positive overlap
Width [mm] 52 52
Grid dimension [mm] 56 56
Pneumatic connections Sub-base size 2 to ISO 5599-1 Sub-base size 2 to ISO 5599-1
Noise level [dB (A)] 85 85
Conforms to standard ISO 5599-1 ISO 5599-1

Flow rates
Standard nominal flow rate [l/min] 2300

Switching times [ms]


Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid VL-5/2-D-2-C 23 39 – –
VL-5/2-D-2-C-EX 23 39 – –
VL-5/2-D-2-FR-C 11 39 – –
VL-5/2-D-2-FR-C-EX 11 39 – –
5/2-way valve, double solenoid J-5/2-D-2-C – – 8 –
J-5/2-D-2-C-EX – – 8 –
JD-5/2-D-2-C – – 8 8
JD-5/2-D-2-C-EX – – 8 8
5/3-way valve VL-5/3G-D-2-C 15 56 – –
VL-5/3G-D-2-C-EX 15 56 – –
VL-5/3E-D-2-C 16 59 – –
VL-5/3E-D-2-C-EX 16 59 – –
VL-5/3B-D-2-C 15 57 – –
VL-5/3B-D-2-C-EX 15 57 – –

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 85


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 52 mm


ATEX
Type VL- ... -EX, J ... -EX
ATEX category for gas II 2G
Type of ignition protection for gas Ex h IIC T4 Gb
ATEX category for dust II 2D
Type of ignition protection for dust Ex h IIIC T130°C Db
Explosion-proof ambient temperature [°C] –10 <= Ta <= +60
CE marking (see declaration of conformity) To EU Explosion Protection Directive (ATEX)

Operating and environmental conditions


Valve function 5/2-way valve 5/3-way valve
Single solenoid Double solenoid
Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 2 ... 16 –0.9 ... +16 –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 16 3 ... 16 2 ... 16 3 ... 16
Ambient temperature [°C] –10 ... +60
Temperature of medium [°C] –10 ... +60
*

Safety characteristics
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

86 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 52 mm


Dimensions  Download CAD data a www.festo.com
5/2-way valves, pneumatic spring reset, 5/2-way bistable valves
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/2- ... 54 38 9 M6 48 9.5 56.5 123.4 61.7 48 24
J-5/2- ...
JD-5/2- ...

5/2-way valves, mechanical spring reset

[3] Captive retaining screws


[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/2- ... -FR- ... 54 38 9 M6 48 9.5 56.5 140.7 61.7 48 24

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 87


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 52 mm


Dimensions  Download CAD data a www.festo.com
5/3-way valves
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/3... 54 38 9 M6 48 9.5 56.5 158 79 48 24

88 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 52 mm


Ordering data 
Circuit symbol Description Weight Part No. Type
[g]
5/2-way valve, single solenoid
Pneumatic spring reset UL – Recognized (OL) 550 151845 VL-5/2-D-2-C
ATEX category apage 86 550 536008 VL-5/2-D-2-C-EX

Mechanical spring reset UL – Recognized (OL) 550 151844 VL-5/2-D-2-FR-C


ATEX category apage 86 550 536011 VL-5/2-D-2-FR-C-EX

5/2-way valve, double solenoid


– – 550 151846 J-5/2-D-2-C
ATEX category apage 86 550 536014 J-5/2-D-2-C-EX

With dominant signal at 14 UL – Recognized (OL) 550 151847 JD-5/2-D-2-C


ATEX category apage 86 550 536017 JD-5/2-D-2-C-EX

5/3-way valve
Normally closed UL – Recognized (OL) 825 151848 VL-5/3G-D-2-C
Mechanical spring reset ATEX category apage 86 825 536020 VL-5/3G-D-2-C-EX

Normally exhausted UL – Recognized (OL) 825 151849 VL-5/3E-D-2-C


Mechanical spring reset ATEX category apage 86 825 536023 VL-5/3E-D-2-C-EX

Normally pressurised UL – Recognized (OL) 825 151850 VL-5/3B-D-2-C


Mechanical spring reset ATEX category apage 86 825 536026 VL-5/3B-D-2-C-EX

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 89


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 65 mm

-M- Flow rate


Up to 4600 l/min

General technical data


Type VL- ... -C, J ... -C VL- ... -EX, J ... -EX
Design Piston spool Piston spool
Sealing principle Soft Soft
Actuation type Pneumatic Pneumatic
Type of control Direct Direct
Direction of flow Reversible Reversible
VL-5/2-D-3-C: non-reversible VL-5/2-D-3-C-EX: non-reversible
Exhaust function Can be throttled Can be throttled
Manual override None None
Type of mounting On sub-base, with through-hole and screw On sub-base, with through-hole and screw
Mounting position Any Any
Nominal size [mm] 14.5 14.5
Overlap Positive overlap Positive overlap
Width [mm] 65 65
Grid dimension [mm] 71 71
Pneumatic connections Sub-base size 3 to ISO 5599-1 Sub-base size 3 to ISO 5599-1
Noise level [dB (A)] 85 85
Conforms to standard ISO 5599-1 ISO 5599-1

Flow rates
Valve function 5/2-way valve 5/3-way valve
Normally closed Normally exhausted Normally
pressurised
Standard nominal flow rate [l/min] 4500 4100 4600 4100

90 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 65 mm


Switching times [ms]
Switching time on Switching time off Switching time Switching time
changeover changeover
(dominant)
5/2-way valve, single solenoid VL-5/2-D-1-C 29 36 – –
VL-5/2-D-1-C-EX 29 36 – –
VL-5/2-D-1-FR-C 13 43 – –
VL-5/2-D-1-FR-C-EX 13 43 – –
5/2-way valve, double solenoid J-5/2-D-1-C – – 8 –
J-5/2-D-1-C-EX – – 8 –
JD-5/2-D-1-C – – 8 8
JD-5/2-D-1-C-EX – – 8 8
5/3-way valve VL-5/3G-D-1-C 17 61 – –
VL-5/3G-D-1-C-EX 17 61 – –
VL-5/3E-D-1-C 18 63 – –
VL-5/3E-D-1-C-EX 18 63 – –
VL-5/3B-D-1-C 16 60 – –
VL-5/3B-D-1-C-EX 16 60 – –

ATEX
Type VL- ... -EX, J ... -EX
ATEX category for gas II 2G
Type of ignition protection for gas Ex h IIC T4 Gb
ATEX category for dust II 2D
Type of ignition protection for dust Ex h IIIC T130°C Db
Explosion-proof ambient temperature [°C] –10 <= Ta <= +60
CE marking (see declaration of conformity) To EU Explosion Protection Directive (ATEX)

Operating and environmental conditions


Valve function 5/2-way valve 5/3-way valve
Single solenoid Double solenoid
Pneumatic spring Mechanical spring
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 2 ... 16 –0.9 ... +16 –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 2 ... 16 3 ... 16 2 ... 16 3 ... 16
Ambient temperature [°C] –10 ... +60
Temperature of medium [°C] –10 ... +60
*

Safety characteristics
Shock resistance Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6

Materials
Housing Die-cast aluminium
Seals HNBR, NBR
Note on materials RoHS-compliant

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 91


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 65 mm


Dimensions  Download CAD data a www.festo.com
5/2-way valves, pneumatic spring reset, 5/2-way bistable valves
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/2- ... 65 48 12 M8 55 12 63.5 145.4 72.7 64 32
J-5/2- ...
JD-5/2- ...

5/2-way valves, mechanical spring reset


[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/2- ... -FR- ... 65 48 12 M8 55 12 63.5 164.7 72.7 64 32

92 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 65 mm


Dimensions  Download CAD data a www.festo.com
5/3-way valves
[3] Captive retaining screws
[4] Slot for inscription label

Type B1 B2 B3 D1 H3 H4 H5 L2 L3 L4 L5
VL-5/3... 65 48 12 M8 55 12 63.5 184 92 64 32

Ordering data 
Circuit symbol Description Weight Part No. Type
[g]
5/2-way valve, single solenoid
Pneumatic spring reset c UL us - Recognized (OL) 810 151864 VL-5/2-D-3-C
ATEX category apage 91 810 536009 VL-5/2-D-3-C-EX

Mechanical spring reset c UL us - Recognized (OL) 810 151863 VL-5/2-D-3-FR-C


ATEX category apage 91 810 536012 VL-5/2-D-3-FR-C-EX

5/2-way valve, double solenoid


– – 810 151865 J-5/2-D-3-C
ATEX category apage 91 810 536015 J-5/2-D-3-C-EX

With dominant signal at 14 c UL us - Recognized (OL) 810 151866 JD-5/2-D-3-C


ATEX category apage 91 810 536018 JD-5/2-D-3-C-EX

5/3-way valve, single solenoid


Normally closed c UL us - Recognized (OL) 910 151867 VL-5/3G-D-3-C
Mechanical spring reset ATEX category apage 91 910 536021 VL-5/3G-D-3-C-EX

Normally exhausted c UL us - Recognized (OL) 910 151868 VL-5/3E-D-3-C


Mechanical spring reset ATEX category apage 91 910 536024 VL-5/3E-D-3-C-EX

Normally pressurised – 910 151869 VL-5/3B-D-3-C


Mechanical spring reset ATEX category apage 91 910 536027 VL-5/3B-D-3-C-EX

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 93


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 76 mm

-M- Flow rate


Up to 6000 l/min

General technical data


Design Piston spool
Sealing principle Soft
Actuation type Pneumatic
Type of control Direct
Direction of flow Reversible
Exhaust function Can be throttled
Manual override None
Type of mounting On sub-base, with through-hole and screw
Mounting position Any
Nominal size [mm] 18
Overlap Positive overlap
Width [mm] 76
Grid dimension [mm] 82
Pneumatic connections Sub-base size 4 to ISO 5599-1
Noise level [dB (A)] 85
Conforms to standard ISO 5599-1

Flow rates
Valve function 5/2-way valve 5/3-way valve
Standard nominal flow rate [l/min] 6000 4800

Switching times [ms]


Switching time on Switching time off Switching time changeover
5/2-way valve, single solenoid VL-5/2-3/4-D-4 25 90 –
5/2-way valve, double solenoid J-5/2-3/4-D-4 – – 20
5/3-way valve VL-5/3G-3/4-D-4 40 130 –
VL-5/3E-3/4-D-4 50 170 –

94 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 76 mm


Operating and environmental conditions
Valve function 5/2-way valve 5/3-way valve
Single solenoid Double solenoid
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] –0.9 ... +16 –0.9 ... +16 –0.9 ... +16
Pilot pressure [bar] 3 ... 16 2 ... 16 3 ... 16
Ambient temperature [°C] –10 ... +60
Temperature of medium [°C] –10 ... +60
*

Materials
Housing Aluminium
Seals NBR
Note on materials RoHS-compliant

Dimensions  Download CAD data a www.festo.com


5/3-way valves
[3] Captive retaining screws

Type B1 B2 D1 H3 H4 L2 L3 L4 L5
VL-5/2-3/4-D-4 76 58 M8 74 14 182 91 80 40
J-5/2-3/4-D-4
VL-5/3E-3/4-D-4
VL-5/3G-3/4-D-4

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 95


Standards-based valves to ISO 5599-1, pneumatic valves

Technical data – Width 76 mm


Ordering data 
Circuit symbol Description Weight Part No. Type
[g]
5/2-way valve, single solenoid
Mechanical spring reset 1800 12461 VL-5/2-3/4-D-4

5/2-way valve, double solenoid


– 1800 12462 J-5/2-3/4-D-4

5/3-way valve
Normally closed 2000 12463 VL-5/3G-3/4-D-4
Mechanical spring reset

Normally exhausted 2000 12464 VL-5/3E-3/4-D-4


Mechanical spring reset

96 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual sub-base

Accessories
Individual sub-base NAS  Lateral connections
Sub-base VABS 
Materials:
Die-cast aluminium
Anodised aluminium

General technical data


Type NAS-1/4 NAS-3/8 NAS-1/2 NAS-3/4 VABS
Conforms to standard ISO 5599-1 –
Based on standard – ISO 5599-1
Actuation type – Electrical
Sealing principle – Soft
Mounting position – Any
Suitability for vacuum – Yes
Type of mounting Via through-hole Via through-hole for M5 screw

Materials
Type NAS-1/4 NAS-3/8 NAS-1/2 NAS-3/4 VABS
Sub-base Die-cast aluminium Anodised Die-cast aluminium
aluminium
Note on materials – – RoHS-compliant
Free of copper and PTFE – –

Operating and environmental conditions


Type NAS-1/4 NAS-3/8 NAS-1/2 NAS-3/4 VABS
Operating medium – – Compressed air to ISO 8573-
1:2010 [7:4:4]
Pilot medium – – Compressed air to ISO 8573-
1:2010 [7:4:4]
Note on the operating/pilot medium – – Lubricated operation possible (in
which case lubricated operation
will always be required)
Operating pressure [bar] – – 0 ... 16
Pilot pressure [bar] – – 0 ... 10
Ambient temperature [°C] – – –10 ... +60
Temperature of medium [°C] – – –10 ... +60
Storage temperature [°C] – – –20 ... +60
Corrosion resistance class CRC1) – – 0
CE marking (see declaration of conformity)2) – – To EU Low Voltage Directive
Certification c UL - Recognized (OL) – –

1) Corrosion resistance class CRC 0 to Festo standard FN 940070


No corrosion stress. Applies to small, visually unimportant standards-based parts such as threaded pins, circlips and clamping sleeves which are usually only available on the market in a phosphated or burnished version (and
possibly oiled) as well as to ball bearings (for components < CRC 3) and plain bearings.
2) Additional information: www.festo.com/catalogue/... d Support/Downloads.

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 97


Standards-based valves to ISO 5599-1, individual sub-base

Accessories
Dimensions – Individual sub-base NAS Download CAD data a www.festo.com

Type B1 D1 D2 D3 H1 H2 H4 H5 H6 L1 L2 L3 L4 L5
NAS-1/4-1A-ISO 48 G1/4 G1/8 5.5 32 10 9 20.3 20.3 110 98 23 60 46
NAS-3/8-2A-ISO 57 G3/8 G1/8 6.6 40 13 9 25 25 124 112 27 71 54
NAS-1/2-3A-ISO 71 G1/2 G1/8 6.6 32 18 9 16 16 149 136 32 91 64
NAS-3/4-4A-ISO 85 G3/4 G1/8 9 42 19 9 21 21 186 170 42 111 84

Dimensions – Sub-base VABS Download CAD data a www.festo.com

Type B1 B2 B3 D1 D2 H1 H2 H3 H4 H5 H6
VABS-S1-1S-G38 48 46 23 G3/8 G1/8 38.5 5 16.3 13.5 26.5 13.5
VABS-S1-1S-N38 3/8 NPT 1/8 NPT
VABS-S1-2S-G12 58 56 28 G1/2 G1/8 45 10 18 16 29 16
VABS-S1-2S-N12 1/2 NPT 1/8 NPT

Type L1 L2 L3 L4 L5 L6 L7 L8 L9 L10
VABS-S1-1S-G38 110 98 6 57 26.5 42 26 45.4 32.3 22.7
VABS-S1-1S-N38
VABS-S1-2S-G12 124 112 6 72 26 46 32 55 34.5 27.5
VABS-S1-2S-N12

98 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual sub-base

Accessories
Ordering data
Designation to VDMA Width Pneumatic connection Weight Part No. Type
1, 2, 3, 4, 5 12, 14 [g]
VDMA 24345-A-1 – G1/4 G1/8 190 q 9484 NAS-1/4-1A-ISO
– 48 mm G3/8 – 230 8032642 VABS-S1-1S-G38
3/8 NPT – 230 8032643 VABS-S1-1S-N38
VDMA 24345-A-2 – G3/8 G1/8 300 11310 NAS-3/8-2A-ISO
– 58 mm G1/2 – 380 8032644 VABS-S1-2S-G12
1/2 NPT – 380 8032645 VABS-S1-2S-N12
VDMA 24345-A-3 – G1/2 G1/8 360 10336 NAS-1/2-3A-ISO
VDMA 24345-A-4 – G3/4 G1/8 1260 152813 NAS-3/4-4A-ISO

-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 99


Standards-based valves to ISO 5599-1, individual sub-base

Accessories
Individual sub-base NAU  Connections underneath

Materials:
Die-cast aluminium
Anodised aluminium

General technical data


Conforms to standard ISO 5599-1
Type of mounting Via through-hole

Materials
Type NAU-1/4 NAU-3/8 NAU-1/2 NAU-3/4
Sub-base Die-cast aluminium Anodised aluminium
Note on materials Free of copper and PTFE –

Operating and environmental conditions


Type NAU-1/4 NAU-3/8 NAU-1/2 NAU-3/4
Certification c UL - Recognized (OL) – –

Dimensions Download CAD data a www.festo.com

Type B1 D1 D2 D3 H1 H2 H3 H4 H5 L1 L2 L3 L4 L5
NAU-1/4-1B-ISO 46 G1/4 G1/8 5.5 30 10 5 7.5 20 110 98 23 60.7 46
NAU-3/8-2B-ISO 56 G3/8 G1/8 6.6 35 13 6.5 8.3 24 124 112 27 70 54
NAU-1/2-3B-ISO 71 G1/2 G1/8 6.6 32 18 9 10 30 149 136 33 90 66
NAU-3/4-4B-ISO 85 G3/4 G1/8 9 28 19 9.5 12 37 186 170 42 111 84

100 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, individual sub-base

Accessories
Ordering data
Designation to VDMA Pneumatic connection Weight Part No. Type
1, 2, 3, 4, 5 12, 14 [g]
VDMA 24345-B-1 G1/4 G1/8 – q 9485 NAU-1/4-1B-ISO
VDMA 24345-B-2 G3/8 G1/8 450 11416 NAU-3/8-2B-ISO
VDMA 24345-B-3 G1/2 G1/8 660 10337 NAU-1/2-3B-ISO
VDMA 24345-B-4 G3/4 G1/8 1080 152814 NAU-3/4-4B-ISO

-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 101


Standards-based valves to ISO 5599-1, manifold components

Accessories
Manifold sub-base   Connections underneath
NAV
VABV Materials:
Die-cast aluminium
Anodised aluminium

Dimensions NAV a page115

General technical data


Type NAV-1/4 NAV-3/8 NAV-1/2 NAV-3/4 VABV
Conforms to standard ISO 5599-1 –
Based on standard – ISO 5599-1
Maximum number of valve positions – 1
Suitability for vacuum – Yes
Exhaust function – Via throttle plate

Materials
Type NAV-1/4 NAV-3/8 NAV-1/2 NAV-3/4 VABV
Sub-base Die-cast aluminium Anodised Die-cast aluminium
aluminium
Note on materials – – RoHS-compliant

Operating and environmental conditions


Type NAV-1/4 NAV-3/8 NAV-1/2 NAV-3/4 VABV
Operating medium – – – Compressed air to ISO 8573-1:2010
[7:4:4]
Pilot medium – – – Compressed air to ISO 8573-1:2010
[7:4:4]
Note on the operating/pilot medium – – – Lubricated operation possible (in
which case lubricated operation will
always be required)
Operating pressure [bar] – – – 0 ... 10
Ambient temperature [°C] – – – –10 ... +50
Temperature of medium [°C] – – – –10 ... +50
Storage temperature [°C] – – – –20 ... +60
Corrosion resistance class CRC1) – – – 0
CE marking (see declaration of conformity)2) – – – To EU Low Voltage Directive
Certification – UL – Recognized (OL) – –

1) Corrosion resistance class CRC 0 to Festo standard FN 940070


No corrosion stress. Applies to small, visually unimportant standards-based parts such as threaded pins, circlips and clamping sleeves which are usually only available on the market in a phosphated or burnished version (and
possibly oiled) as well as to ball bearings (for components < CRC 3) and plain bearings.
2) Additional information: www.festo.com/catalogue/... d Support/Downloads.

102 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
Dimensions – VABV Download CAD data a www.festo.com

Type B1 B2 B3 H1 H2 H3 H4 H5 L1 L2 L3
VABV-S1-1SB-G38 44 16.5 16 65 13.5 20.5 34 15 124 96.2 19.9
VABV-S1-1SB-N38
VABV-S1-2SB-G12 59 19.5 22 35.5 14.5
VABV-S1-2SB-N12

Ordering data
Designation to VDMA Width Pneumatic connection Weight Part No. Type
2, 4 12, 14 [g]
VDMA 24345-C-1 – G1/4 G1/8 240 q 10173 NAV-1/4-1C-ISO
– 44 mm G3/8 – 490 8029812 VABV-S1-1SB-G38
3/8 NPT – 490 8029813 VABV-S1-1SB-N38
VDMA 24345-C-2 – G3/8 G1/8 400 11305 NAV-3/8-2C-ISO
– 59 mm G1/2 – 670 8029814 VABV-S1-2SB-G12
1/2 NPT – 670 8029815 VABV-S1-2SB-N12
VDMA 24345-C-3 – G1/2 G1/8 700 10175 NAV-1/2-3C-ISO
VDMA 24345-C-4 – G3/4 G1/8 1400 11139 NAV-3/4-4C-ISO

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 103


Standards-based valves to ISO 5599-1, manifold components

Accessories
Supply plate VABF  Materials:
Die-cast aluminium
Wrought aluminium alloy
PA

General technical data


Based on standard ISO 5599-1
Maximum number of valve positions 1
Suitability for vacuum Yes
Exhaust function Via throttle plate

Materials
Type VABF-S1-1-P1A11 VABF-S1-1-P1A12
Exhaust plate Wrought aluminium alloy PA
Supply plate Anodised aluminium Die-cast aluminium
Note on materials RoHS-compliant RoHS-compliant

Operating and environmental conditions


Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 0 ... 10
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +50
Storage temperature [°C] –20 ... +60
Corrosion resistance class CRC1) 0
CE marking (see declaration of conformity)2) To EU Low Voltage Directive

1) Corrosion resistance class CRC 0 to Festo standard FN 940070


No corrosion stress. Applies to small, visually unimportant standards-based parts such as threaded pins, circlips and clamping sleeves which are usually only available on the market in a phosphated or burnished version (and
possibly oiled) as well as to ball bearings (for components < CRC 3) and plain bearings.
2) Additional information: www.festo.com/catalogue/... d Support/Downloads.

104 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
Dimensions  Download CAD data a www.festo.com
Port 3 and 5 separated

Type B1 B2 B3 H1 H3 H4 H5 L1 L2 L3 L4 L5
VABF-S1-1-P1A11 44 5.5 22 87 52.5 20.5 13.5 124 96.2 19.9 44 40

Port 3 and 5 combined

Type B1 B2 B3 H1 H2 H3 H4 H5 L1 L2 L3
VABF-S1-1-P1A12 44 5.8 22 115.2 93.8 52.5 20.5 13.5 124 96.2 19.9

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 105


Standards-based valves to ISO 5599-1, manifold components

Accessories
Ordering data
Width Description Pneumatic Weight Part No. Type
connection
1, 3, 5 [g]
44 mm Port 3 and 5 separated G1/2 660 8037655 VABF-S1-1-P1A11-G12
1/2 NPT 660 8037656 VABF-S1-1-P1A11-N12

Port 3 and 5 combined G1/2 650 8037653 VABF-S1-1-P1A12-G12


1/2 NPT 650 8037654 VABF-S1-1-P1A12-N12

106 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
90°-connection plate NAW  Ports at the side and on top

Materials:
Die-cast aluminium
Anodised aluminium

Dimensions a page 115

General technical data


Conforms to standard ISO 5599-1

Operating and environmental conditions


Type NAW-1/4 NAW-3/8 NAW-1/2 NAW-3/4
Note on materials Free of copper and PTFE –

Ordering data
Designation to VDMA Pneumatic connection Weight Part No. Type
2 4 [g]
VDMA 24345-E-1 G1/4 G1/4 360 11304 NAW-1/4-1E-ISO
VDMA 24345-E-2 G3/8 G3/8 600 11307 NAW-3/8-2E-ISO
VDMA 24345-E-3 G1/2 G1/2 920 11309 NAW-1/2-3E-ISO
VDMA 24345-E-4 G3/4 G3/4 1550 11141 NAW-3/4-4E-ISO

Manifold sub-base with 90° Connections at the side and


connections NAVW  underneath

Materials:
Die-cast aluminium

Dimensions a page 115

General technical data


Conforms to standard ISO 5599-1

Operating and environmental conditions


Operating medium Compressed air to ISO 8573-1:2010 [7:–:–]
*

Ordering data
Pneumatic connection Weight Part No. Type
1, 2, 4 12, 14 [g]
G1/4 G1/8 320 152789 NAVW-1/4-1-ISO
G3/8 G1/8 550 152790 NAVW-3/8-2-ISO
G1/2 G1/8 1020 152791 NAVW-1/2-3-ISO

-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 107


Standards-based valves to ISO 5599-1, manifold components

Accessories
End plate kit NEV  Materials:
Die-cast aluminium
Anodised aluminium

Dimensions NEV a page 115

General technical data


Conforms to standard ISO 5599-1

Operating and environmental conditions


Type NEV-1DA NEV-2DA NEV-3DA NEV-4DA
Note on materials Free of copper and PTFE –

Ordering data
Designation to VDMA Pneumatic connection Weight Part No. Type
1, 3, 5 [g]
VDMA 24345-D-1 G3/8 280 q 10174 NEV-1DA/DB-ISO
VDMA 24345-D-2 G1/2 450 11306 NEV-2DA/DB-ISO
VDMA 24345-D-3 G1 760 10176 NEV-3DA/DB-ISO
VDMA 24345-D-4 G1 1390 11140 NEV-4DA/DB-ISO

-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.

108 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
End plate VABE  Materials:
Die-cast aluminium

General technical data


Based on standard ISO 5599-1
Suitability for vacuum Yes
Exhaust function Via throttle plate
Type of mounting Via through-hole for M6 screw

Materials
End plate Die-cast aluminium
Note on materials RoHS-compliant

Operating and environmental conditions


Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 0 ... 10
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +50
Storage temperature [°C] –20 ... +60
Corrosion resistance class CRC1) 0
CE marking (see declaration of conformity)2) To EU Low Voltage Directive

1) Corrosion resistance class CRC 0 to Festo standard FN 940070


No corrosion stress. Applies to small, visually unimportant standards-based parts such as threaded pins, circlips and clamping sleeves which are usually only available on the market in a phosphated or burnished version (and
possibly oiled) as well as to ball bearings (for components < CRC 3) and plain bearings.
2) Additional information: www.festo.com/catalogue/... d Support/Downloads.

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 109


Standards-based valves to ISO 5599-1, manifold components

Accessories
Dimensions  Download CAD data a www.festo.com
Left end plate

Type B1 B2 B3 B4 D1 D2 D3 H1 H2 H3 H4 L1 L2 L3 L4 L5 L6 L7 L8
VABE-S1-1L...-G12 44 5.8 6 6 G1/2 G1/4 6.5 77.9 33 25.9 20 124.9 108 72 26.4 35.4 54 27 8.4
VABE-S1-1L...-N12 1/2 NPT 1/4 NPT
VABE-S1-2L...-G34 G3/4 G1/4
VABE-S1-2L...-N34 3/4 NPT 1/4 NPT

Right end plate

Type B1 B3 B4 D1 D2 D3 H1 H2 H3 H4 L1 L2 L3 L4 L5 L6 L7 L8
VABE-S1-1R...-G12 44 6 6 G1/2 G1/4 6.5 77.4 33 25.9 19.5 124 108 72 26 35 54 27 8
VABE-S1-1R...-N12 1/2 NPT 1/4 NPT
VABE-S1-2R...-G34 G3/4 G1/4
VABE-S1-2R...-N34 3/4 NPT 1/4 NPT

110 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
Ordering data
Width Pneumatic connection Weight Pilot air supply Part No. Type
1, 3, 5 12, 14 [g]
Left end plate
44 mm G1/2 G1/4 400 Internal 8032662 VABE-S1-1L-G12
External 8032660 VABE-S1-1LZ-G12
1/2 NPT 1/4 NPT 400 Internal 8032663 VABE-S1-1L-N12
External 8032661 VABE-S1-1LZ-N12
G3/4 G1/4 360 Internal 8032666 VABE-S1-2L-G34
External 8032664 VABE-S1-2LZ-G34
3/4 NPT 1/4 NPT 360 Internal 8032667 VABE-S1-2L-N34
External 8032665 VABE-S1-2LZ-N34

Right end plate


44 mm G1/2 G1/4 410 Internal 8032670 VABE-S1-1R-G12
External 8032668 VABE-S1-1RZ-G12
1/2 NPT 1/4 NPT 410 Internal 8032671 VABE-S1-1R-N12
External 8032669 VABE-S1-1RZ-N12
G3/4 G1/4 370 Internal 8032674 VABE-S1-2R-G34
External 8032672 VABE-S1-2RZ-G34
3/4 NPT 1/4 NPT 370 Internal 8032675 VABE-S1-2R-N34
External 8032673 VABE-S1-2RZ-N34

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 111


Standards-based valves to ISO 5599-1, manifold components

Accessories
Cover plate NDV  Materials:
Width 42 mm, 52 mm, 65 mm:
Steel

Width 76 mm:
Wrought aluminium alloy

Dimensions a page 115

General technical data


Conforms to standard ISO 5599-1

Operating and environmental conditions


Operating medium Compressed air to ISO 8573-1:2010 [7:–:–]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)

Ordering data
Width Weight Part No. Type
[g]
42 mm 113 q 9489 NDV-1-ISO
52 mm 166 11308 NDV-2-ISO
65 mm 314 10340 NDV-3-ISO
76 mm 1480 11142 NDV-4-ISO

Isolating disc NSC  Materials:


Wrought aluminium alloy

Dimensions a 115

General technical data


Conforms to standard ISO 5599-1

Operating and environmental conditions


Width 42 mm 52 mm 65 mm 76 mm
Note on materials Free of copper and PTFE –

Ordering data
Width Pneumatic connection Weight Part No. Type
[g]
42 mm G1/4 6 q 11550 NSC-1/4-1-ISO
52 mm G3/8 9.2 11908 NSC-3/8-2-ISO
65 mm G1/2 20 11551 NSC-1/2-3-ISO
76 mm G3/4 24 11699 NSC-3/4-4-ISO

112 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
Duct separation VABD  Materials:
Steel, NBR

General technical data


Based on standard ISO 5599-1
Suitability for vacuum Yes
Exhaust function Via throttle plate
Type of mounting Via through-hole for M6 screw

Materials
Separator plate Steel
NBR
Note on materials RoHS-compliant

Operating and environmental conditions


Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Pilot medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [bar] 0 ... 10
Ambient temperature [°C] –10 ... +50
Temperature of medium [°C] –10 ... +50
Storage temperature [°C] –20 ... +60
Corrosion resistance class CRC1) 0
CE marking (see declaration of conformity)2) To EU Low Voltage Directive

1) Corrosion resistance class CRC 0 to Festo standard FN 940070


No corrosion stress. Applies to small, visually unimportant standards-based parts such as threaded pins, circlips and clamping sleeves which are usually only available on the market in a phosphated or burnished version (and
possibly oiled) as well as to ball bearings (for components < CRC 3) and plain bearings.
2) Additional information: www.festo.com/catalogue/... d Support/Downloads.

Ordering data
Duct separation Weight Part No. Type
[g]
Duct 1 60 8029438 VABD-S1-1-P1-C
Duct 3 and duct 5 70 8029439 VABD-S1-1-P2-C
Ducts 1, 3 and 5 75 8029440 VABD-S1-1-P3-C
Ducts 1, 3, 5, 12 and 14 75 8029441 VABD-S1-1-P6-C
Duct 12 and duct 14 60 8036068 VABD-S1-1-P7-C

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 113


Standards-based valves to ISO 5599-1, manifold components

Accessories
Intermediate plate NZV  For connecting manifold sub-bases of
different sizes

Materials:
Die-cast aluminium, anodised

General technical data


Based on standard ISO 5599-1
Note on materials Free of copper and PTFE

Dimensions Download CAD data a www.festo.com


NZV-1-2 NZV-3-2/1

Type B1 B2 B3 B4 D1 D2 D3 D4 H1 H2 L1 L2 L3 L4 L5 T1 T2
@ @
NZV-1-2 47 24 23 – M6 M5 7 – 25 7.5 135 115 95 30 – 13 12
NZV-3-2/1 56 25 24 22 M6 M5 12 9 30 15 190 168 115 52 95 12 10

Ordering data
Weight Part No. Type
[g]
For manifold sub-bases of width 42 mm, 52 mm 393 164940 NZV-1-2
For manifold sub-bases of width 42 mm and 65 mm or 52 mm and 65 mm 473 12911 NZV-3-2/1

114 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, manifold components

Accessories
Dimensions – Manifold assembly Download CAD data a www.festo.com

[1] Left end plate, end plate kit NEV [3] Cover plate NDV [5] 90° connection plate NAW [7] Manifold sub-base with 90°
[2] Manifold sub-base NAV [4] Right end plate, end plate kit [6] Port pattern to ISO 5599-1 connections NAVW
NEV [8] Isolating disc NSC

Width B1 B2 B3 B4 B5 B6 B7 B8 B9 D1 D2 D3 D4 D5 D6
@ @ @
42 mm 43 22 42 40 11 7.5 1.5 4 21.6 G1/4 G3/8 G1/8 10 5.5 7
52 mm 56 26 55 50 13 6 5 6 27 G3/8 G1/2 G1/8 11 6.6 9
65 mm 71 30 70 70 15 8 6 6 35.5 G1/2 G1 G1/8 15 9 12
76 mm 82 30 80 80 15 9 8 – – G3/4 G1 G1/8 15 9 12

Width H1 H2 H3 H4 H5 H6 H7 L1 L2 L3 L4 L5 L6 L7 T1

42 mm 81 46 44 50.5 12.5 37 5 110 95 80 28 26 11 11 5.7


52 mm 85 47 45 60 15 40 5 135 115 96 35 30 15 14 6.8
65 mm 99 56 54 66 17.5 45 5 190 168 120 52 38 19 19 9
76 mm 120 58 55 – – 65 5 215 184 – 56 52 – – 9

-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 115


Standards-based valves to ISO 5599-1, throttle plate

Accessories
Exhaust air flow control for 3 and 5.

General technical data


Type VABF-S1-1-F1B1-C VABF-S1-2-F1B1-C GRO-ZP-3-ISO
Based on standard ISO 5599-1
Pneumatic vertical stacking Throttle plate, exhaust air flow control
Mounting position Any
Type of mounting Via through-hole
Standard nominal flow rate [l/min] 1100 – 1500
Degree of protection IP65 IP65 –
NEMA4 NEMA4 –

Materials
Housing Die-cast aluminium
Note on materials RoHS-compliant

Operating and environmental conditions


Type VABF-S1-1-F1B1-C VABF-S1-2-F1B1-C GRO-ZP-3-ISO
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4] Compressed air to ISO 8573-
1:2010 [7:–:–]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated Lubricated operation possi-
operation will always be required) ble (in which case lubricated
operation will always be
required)
Operating pressure [MPa] –0.09 ... +1 –0.09 ... +1 –
[bar] –0.9 ... +10 –0.9 ... +10 0 ... +16
Input pressure 1 [MPa] – +0.05 ... +1 –
[bar] – +0.5 ... +10 –
[psi] – 7.25 ... 145 –
Ambient temperature [°C] –5 ... +50 –5 ... +50 –20 ... +80
Temperature of medium [°C] – – –20 ... +80

116 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, throttle plate

Accessories
Standard nominal flow rate qnN as a function of the turns n of the regulating screw
VABF-S1-1-F1B1-C

1 [1] Flow control screw from 4 to 5


[2] Flow control screw from 2 to 3

VABF-S1-2-F1B1-C

1 [1] Flow control screw from 2 to 3


[2] Flow control screw from 4 to 5

GRO-ZP-3-ISO

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 117


Standards-based valves to ISO 5599-1, throttle plate

Accessories
Dimensions  Download CAD data a www.festo.com
VABF-S1-...
[1] Captive retaining screws
[2] Port pattern to ISO 5599-1

GRO-ZP-3-ISO
[1] Adjusting screw for flow control
[2] Captive retaining screws

Type Width B1 B2 B3 D1 H1 H2 H3 H4 L1 L2 L3 L5 L6 T1
VABF-S1-1-F1B1-C 42 mm 39.9 24.3 16.1 9.3 17.5 9.2 – 28 105.3 – – – 32 7.3
VABF-S1-2-F1B1-C 52 mm 52 32.5 22.5 13.4 29.5 13.5 – 45 131 – – – 40.9 10
GRO-ZP-3-ISO 65 mm 70 48 – M8 33 12 16.5 – 132 64 32 7 – –

Ordering data 
Circuit symbol Description Width Weight Part No. Type
[g]
Exhaust air flow control valve 42 mm 220 549102 VABF-S1-1-F1B1-C
52 mm 565 555788 VABF-S1-2-F1B1-C
65 mm 850 119674 GRO-ZP-3-ISO

118 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, vertical supply plate

Accessories
Alternative compressed air supply for
port 1 of the mounted valve.

General technical data


Type VABF-S1-1-P1A3-G38 VABF-S1-2-P1A3-G12
Based on standard ISO 5599-1
Pneumatic vertical stacking Alternative compressed air supply for 1
Mounting position Any
Type of mounting On individual sub-base, on manifold sub-base
Standard nominal flow rate [l/min] 1300 2800
Pneumatic connection 1 G3/8 G1/2
Degree of protection IP65 IP65
NEMA4 NEMA4

Materials
Housing Die-cast aluminium
Note on materials RoHS-compliant

Operating and environmental conditions


Type VABF-S1-1-P1A3-G38 VABF-S1-2-P1A3-G12
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [MPa] –0.09 ... +1 –0.09 ... +1
[bar] –0.9 ... +10 –0.9 ... +10
Input pressure 1 [MPa] – +0.05 ... +1
[bar] – +0.5 ... +10
[psi] – 7.25 ... 145
Ambient temperature [°C] –5 ... +50 –5 ... +50

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 119


Standards-based valves to ISO 5599-1, vertical supply plate

Accessories
Dimensions  Download CAD data a www.festo.com
[1] Captive screws
[2] Port pattern to ISO 5599-1

Type B1 B2 D1 H1 H4 L1 L6 T1
VABF-S1-1-P1A3-G38 42.1 24.2 G3/8 32.7 45.3 117.6 35.8 7.9
VABF-S1-2-P1A3-G12 54 31 G1/2 42.4 58.9 136 38 10

Ordering data 
Circuit symbol Description Width Standard Weight Part No. Type
nominal flow
rate
[l/min] [g]
Vertical supply plate 42 mm 1300 340 549100 VABF-S1-1-P1A3-G38
52 mm 2800 605 555785 VABF-S1-2-P1A3-G12

120 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, vertical pressure shut-off plate

Accessories
Vertical pressure shut-off plate for
blocking duct 1 and duct 14 upstream
of a valve.

General technical data


Type VABF-S1-1-L1D1-C VABF-S1-2-L1D1-C
Based on standard ISO 5599-1
Pneumatic vertical stacking Shut-off for 1 Alternative compressed air supply for 1
Mounting position Any
Type of mounting On individual sub-base, on manifold sub-base
Standard nominal flow rate [l/min] 1200 1950
Pneumatic connection 1 G3/8 G1/2
Degree of protection IP65 IP65
NEMA4 NEMA4

Materials
Housing Die-cast aluminium
Note on materials RoHS-compliant

Operating and environmental conditions


Type VABF-S1-1-L1D1-C VABF-S1-2-L1D1-C
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated operation will always be required)
Operating pressure [MPa] –0.09 ... +1 –0.09 ... +1
[bar] –0.9 ... +10 –0.9 ... +10
Input pressure 1 [MPa] – +0.05 ... +1
[bar] – +0.5 ... +10
[psi] – 7.25 ... 145
Ambient temperature [°C] –5 ... +50 –5 ... +50

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 121


Standards-based valves to ISO 5599-1, vertical pressure shut-off plate

Accessories
Dimensions  Download CAD data a www.festo.com
[1] Captive screws
[2] Port pattern to ISO 5599-1

Type B1 B2 D1 H1 H2 H4 L1 L6 T1
VABF-S1-1-L1D1-C 42.1 26.7 12.8 15.6 1.6 45.3 173.8 92 7.9
VABF-S1-2-L1D1-C 54 32.6 14 21.3 1.6 58.7 191.2 93.2 10

Ordering data 
Circuit symbol Description Width Standard Weight Part No. Type
nominal flow
rate
[l/min] [g]
Vertical pressure shut-off plate 42 mm 1200 600 549103 VABF-S1-1-L1D1-C
52 mm 1950 1030 555790 VABF-S1-2-L1D1-C

122 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pressure regulator

Accessories
The pressure regulator enables a
particular pressure in the regulated
port to be set manually upstream or
  downstream of the valve.

General technical data


Type VABF-S1-1-R... VABF-S1-2-R... LR-ZP-...-3
Width [mm] 42 52 65
Based on standard ISO 5599-1 ISO 5599-1 ISO 5599-1
Pneumatic vertical stacking Pressure regulators Pressure regulators Pressure regulators
Design – – Piston
Regulator function Output pressure constant Output pressure constant –
With secondary exhausting With secondary exhausting –
Mounting position Any Any –
Type of mounting On individual sub-base On individual sub-base –
On manifold sub-base On manifold sub-base –
Optional pressure gauge Possible Possible –
Pressure gauge connection With retaining clamp With retaining clamp –
Degree of protection IP65 IP65 –
NEMA4 NEMA4 –

Materials
Type VABF-S1-1-R... VABF-S1-2-R... LR-ZP-...-3
Regulator housing Die-cast aluminium Die-cast aluminium Die-cast aluminium, steel
Control unit PA PA –
Seals – – NBR
Note on materials RoHS-compliant RoHS-compliant RoHS-compliant
Free of paint-wetting Free of paint-wetting Contains paint-wetting
impairment substances impairment substances impairment substances

Operating and environmental conditions


Type VABF-S1-1-R... VABF-S1-2-R... LR-ZP-...-3
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4] –
Note on the operating/pilot medium Lubricated operation possible (in which case lubricated –
operation will always be required)
Input pressure 1 [MPa] 0.05 ... 1 0.05 ... 1 –
[bar] +0.5 ... +10 +0.5 ... +10 Max. 14
[psi] 7.25 ... 145 7.25 ... 145 –
Ambient temperature [°C] –5 ... +50 –5 ... +50 –
Certification – – UL – Recognized (OL)

Product weight
Type VABF-S1-1-R... VABF-S1-2-R... LR-ZP-...-3
Regulated port 1 640 g 1190 g 1220 g
2 640 g 1230 g 1220 g
4 640 g 1230 g 1220 g
2 and 4 920 g 1990 g 1770 g

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 123


Standards-based valves to ISO 5599-1, pressure regulator

Accessories
Dimensions  Download CAD data a www.festo.com
VABF-S1-1-..., VABF-S1-2-...

[1] Captive retaining screws [3] Regulator housing [5] Regulator knob, locked [6] Regulator knob during pressure
[2] Port pattern to ISO 5599-1 [4] Pressure gauge setting

Type B1 B2 H1 H2 H3 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 T1
Regulator plate, width 42 mm
VABF-S1-1-R1... 42.1 23.6 115 112 87.1 – 207.1 – 125.3 – – 49.4 36 27 9 7.9
VABF-S1-1-R2... – – 216.2 125.3 – –
VABF-S1-1-R3... – – – 125.3 150.3 216.1
VABF-S1-1-R4... 311.6 – – – – –
VABF-S1-1-R5... 311.6 – – – – –
VABF-S1-1-R6... – – 216.2 125.3 – –
VABF-S1-1-R7... – – – 125.3 150.3 216.1

Regulator plate, width 52 mm


VABF-S1-2-R1... 54 23.6 182 167 94.4 – 250.2 – 152.2 – – 49.4 48 38 12 10
VABF-S1-2-R2... – – 264.2 152.2 – –
VABF-S1-2-R3... – – – 152.2 180.2 264.2
VABF-S1-2-R4... 380.4 – – – – –
VABF-S1-2-R5... 380.4 – – – – –
VABF-S1-2-R6... – – 264.2 152.2 – –
VABF-S1-2-R7... – – – 152.2 180.2 264.2

124 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pressure regulator

Accessories
Dimensions  Download CAD data a www.festo.com
LR-ZP-...-3

[1] Pressure gauge connection [3] Port pattern to ISO 5599-1 [4] Captive retaining screws [5] Rotary knob
G1/8
[2] Adjusting screw

Type B H H1 H2 L1 L2 L3 L4 L5 L6 L7 L8
Regulator plate, width 65 mm
LR-ZP-P-D-3 70 63 65 14 201.5 – 274 – – – 119 –
LR-ZP-B-D-3 201.5 – – – 274 72.5 – 119
LR-ZP-A-D-3 201.5 – – 403 – – 119 119
LR-ZP-A/B-D-3 201.5 260 – – – – 119 –

Flow rate qn as a function of output pressure p2


LR-ZP-A-D-3, LR-ZP-B-D-3, LR-ZP-A/B-D-3 LR-ZP-P-D-3

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 125


Standards-based valves to ISO 5599-1, pressure regulator

Accessories
Ordering data 
Regulated port Regulator Control range Part No. Type
Regulator plate, width 42 mm
1 P 0.05 ... 0.6 MPa 546817 VABF-S1-1-R1C2-C-6
0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546818 VABF-S1-1-R1C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2 B 0.05 ... 0.6 MPa 546821 VABF-S1-1-R2C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546822 VABF-S1-1-R2C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2, reversible B 0.05 ... 0.6 MPa 546827 VABF-S1-1-R6C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546828 VABF-S1-1-R6C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

4 A 0.05 ... 0.6 MPa 546819 VABF-S1-1-R3C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546820 VABF-S1-1-R3C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

4, reversible A 0.05 ... 0.6 MPa 546829 VABF-S1-1-R7C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546830 VABF-S1-1-R7C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2 and 4 AB 0.05 ... 0.6 MPa 546823 VABF-S1-1-R4C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546824 VABF-S1-1-R4C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2 and 4, reversible AB 0.05 ... 0.6 MPa 546825 VABF-S1-1-R5C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 546826 VABF-S1-1-R5C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

126 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1, pressure regulator

Accessories
Ordering data
Regulated port Regulator Control range Part No. Type
Regulator plate, width 52 mm
1 P 0.05 ... 0.6 MPa 555757 VABF-S1-2-R1C2-C-6
0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555758 VABF-S1-2-R1C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2 B 0.05 ... 0.6 MPa 555759 VABF-S1-2-R2C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555760 VABF-S1-2-R2C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2, reversible B 0.05 ... 0.6 MPa 555767 VABF-S1-2-R6C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555768 VABF-S1-2-R6C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

4 A 0.05 ... 0.6 MPa 555761 VABF-S1-2-R3C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555762 VABF-S1-2-R3C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

4, reversible A 0.05 ... 0.6 MPa 555769 VABF-S1-2-R7C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555770 VABF-S1-2-R7C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2 and 4 AB 0.05 ... 0.6 MPa 555763 VABF-S1-2-R4C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555764 VABF-S1-2-R4C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2 and 4, reversible AB 0.05 ... 0.6 MPa 555765 VABF-S1-2-R5C2-C-6


0.5 ... 6 bar
7.25 ... 87 psi
0.05 ... 1 MPa 555766 VABF-S1-2-R5C2-C-10
0.5 ... 10 bar
7.25 ... 145 psi

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 127


Standards-based valves to ISO 5599-1, pressure regulator

Accessories
Ordering data
Regulated port Regulator Control range Part No. Type
Regulator plate, width 65 mm
1 P 0 ... 12 bar 35968 LR-ZP-P-D-3

2 B 0.5 ... 12 bar 35426 LR-ZP-B-D-3

4 A 0.5 ... 12 bar 35971 LR-ZP-A-D-3

2, 4 AB 0.5 ... 12 bar 35429 LR-ZP-A/B-D-3

Ordering data – Accessories


Width Weight Part No. Type
[g]
Pressure gauge for intermediate pressure regulator plates LR-ZP 65 mm 64.5 345395 MA-40-16-1/8

-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.

128 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Accessories
Ordering data
Description Voltage Cable length Part No. Type
[m]
Solenoid coil MSF 
Solenoid coil 12 V DC – 34410 MSFG-12-OD
24 V DC and 42 V AC, 50 ... 60 Hz – 34411 MSFG-24/42-50/60-OD
42 V DC – 34413 MSFG-42-OD
24 V AC – 34415 MSFW-24-50/60-OD
48 V AC, 50 ... 60 Hz – 34418 MSFW-48-50/60-OD
110 V AC, 50 ... 60 Hz and 120 V AC, 60 Hz – 34420 MSFW-110-50/60-OD
230 V AC, 50 ... 60 Hz and 240 V AC, 60 Hz – 34422 MSFW-230-50/60-OD
240 V AC, 50 ... 60 Hz – 34424 MSFW-240-50/60-OD
Solenoid coil with socket MSSD 12 V DC – 4526 MSFG-12
24 V DC and 42 V AC, 50 ... 60 Hz – 4527 MSFG-2 4/42-5 0/60
24 V AC – 4534 MSFW-24-5 0/60
110 V AC, 50 ... 60 Hz and 120 V AC, 60 Hz – 6720 MSFW-110-5 0/60
230 V AC, 50 ... 60 Hz and 240 V AC, 60 Hz – 4540 MSFW-230-5 0/60
Solenoid coil for ATEX environment 24 V DC 1 8059804 VACF-B-K1-1-1-EX4-M
5 8059805 VACF-B-K1-1-5-EX4-M
24 V AC, 50 ... 60 Hz 1 8059808 VACF-B-K1-1A-1-EX4-M
110 V AC, 50 ... 60 Hz 1 8059811 VACF-B-K1-16B-1-EX4-M
5 8059812 VACF-B-K1-16B-5-EX4-M
230 V AC, 50 ... 60 Hz 1 8059809 VACF-B-K1-3A-1-EX4-M
5 8059810 VACF-B-K1-3A-5-EX4-M

Solenoid coil MSN1 
Solenoid coil 24 V DC – 123060 MSN1G-24DC-OD
12 V DC and 24 V AC, 50 ... 60 Hz – 170152 MSN1W-24AC/12DC
110 V AC, 50 ... 60 Hz – 123061 MSN1W-110AC-OD
230 V AC, 50 ... 60 Hz – 123062 MSN1W-230AC-OD

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 129


Standards-based valves to ISO 5599-1

Accessories
Ordering data
Description Cable length Part No. Type
[m]
Electrical accessories for solenoid coil MSF 
Angled socket Screw terminal Cable connector Pg9 – 34431 MSSD-F
Cable connector M16 – 59710 MSSD-F-M16
Insulation Cable connector M16 – 192746 MSSD-F-S-M16
displacement
technology
PUR cable sheath, connection 24 AC/DC • Signal status indication 0.3 3679773 NEBV-B2W3F-P-K-0.3-N-M12W3
technology M12x1 A-coded • Protective circuit 0.6 3679774 NEBV-B2W3F-P-K-0.6-N-M12W3
110 AC/DC – 0.3 3579463 NEBV-B2W3-K-0.3-N-M12W3
0.6 3579464 NEBV-B2W3-K-0.6-N-M12W3
PUR cable sheath 24 AC/DC • Signal status indication 0.6 3679778 NEBV-B2W3F-P-K-0.6-N-LE3
• Protective circuit
230 AC/DC – 0.6 3579468 NEBV-B2W3-K-0.6-N-LE3
PVC cable sheath 24 V DC Signal status indication 2.5 30935 KMF-1-24DC-2.5-LED
5 30937 KMF-1-24DC-5-LED
10 193458 KMF-1-24DC-10-LED
230 V AC – 2.5 30936 KMF-1-230AC-2.5
5 30938 KMF-1-230AC-5
Illuminating seal 12 ... 24 V DC Signal status indication – 19143 MF-LD-12-24DC
230 V DC/V AC Signal status indication – 19144 MF-LD-230AC

Electrical accessories for solenoid coil MSN1 and MD 


Angled socket Screw terminal Cable connector Pg9 – 34583 MSSD-C
Cable connector M16 – 539709 MSSD-C-M16
Insulation Cable connector M16 – 192748 MSSD-C-S-M16
displacement
technology
PUR cable sheath, connection 24 AC/DC • Signal status indication 0.3 3679771 NEBV-A1W3F-P-K-0.3-N-M12W3
technology M12x1 A-coded • Protective circuit 0.6 3679772 NEBV-A1W3F-P-K-0.6-N-M12W3
110 AC/DC – 0.3 3579461 NEBV-A1W3-K-0.3-N-M12W3
0.6 3579462 NEBV-A1W3-K-0.6-N-M12W3
PUR cable sheath 24 AC/DC • Signal status indication 0.6 3679776 NEBV-A1W3F-P-K-0.6-N-LE3
• Protective circuit
230 AC/DC – 0.6 3579466 NEBV-A1W3-K-0.6-N-LE3
PVC cable sheath 24 V DC Signal status indication 2.5 30931 KMC-1-24DC-2.5-LED
5 30933 KMC-1-24DC-5-LED
10 193459 KMC-1-24DC-10-LED
230 V AC – 2.5 30932 KMC-1-230AC-2.5
5 30934 KMC-1-230AC-5
Illuminating seal 12 ... 24 V DC Signal status indication – 19145 MC-LD-12-24DC
230 V DC/V AC Signal status indication – 19146 MC-LD-230AC

130 d Internet: www.festo.com/catalogue/... Subject to change – 2021/09


Standards-based valves to ISO 5599-1

Accessories
Ordering data
Description Part No. Type PU1)
Electrical accessories for valves with central plug 
Angled socket, M12, 4-pin, type A, screw terminal – 12956 SIE-WD-TR 1

Modular system for a choice of connecting cables 0.1 ... 30 m – NEBU-... –


a Internet: nebu

Connecting cable, 2.5 550326 NEBU-M12G5-K-2.5-LE4 1


straight socket, M12x1, 5-pin, open cable end, 4-wire 5 541328 NEBU-M12G5-K-5-LE4 1

Connecting cable, 2.5 550325 NEBU-M12W5-K-2.5-LE4 1


angled socket, M12x1, 5-pin, open cable end, 4-wire 5 541329 NEBU-M12W5-K-5-LE4 1

Pressure gauge 
With cartridge connection for regulator 10 bar 543487 PAGN-26-16-P10 1
6 bar 543488 PAGN-26-10-P10 1

Seal 
Enables the valves with central plug M12, 3-pin, to be assembled on the sub-bases of the valve terminal 571343 VABD-S2-1-S-C 2
VTS/VTSA-F

Inscription label 
Inscription label for valves 161937 IBS-9x17 24

Clip-on inscription label holder for valve cap, for valves with central plug M12, 3-pin 540888 ASCF-T-S6 5

Manual override 
Cover cap for manual override, non-detenting For valves with central plug M12, 3-pin 541010 VAMC-S6-CH 10

Cover cap for manual override, concealed For valves with central plug M12, 3-pin 541011 VAMC-S6-CS 10

Heavy-duty cover cap for manual override, For valves with central plug M12, 3-pin 4105147 VAMC-B-S6-CTR 10
non-detenting, detenting via accessory

Tool for manual override For MN1H/MFH valves 157651 AHB-MD/MF/MV 1


For heavy-duty cover cap, detenting position 1662543 AHB-MEB-B 1

1) Packaging unit

2021/09 – Subject to change d Internet: www.festo.com/catalogue/... 131

You might also like