Side Channel Blower Installation Guide
Side Channel Blower Installation Guide
Operating Instructions
The gas shall be free from vapours that would condensate under the         The allowed media and operational limits according to the “Product
temperature and pressure conditions inside the side channel blower.        Description” and the “Installation Prerequisites” of the side channel
                                                                           blower shall be observed both by the manufacturer of the machinery
The side channel blower is suitable for continuous operation, provided     into which the side channel blower is to be incorporated and by the
that the housing can transmit heat to the environment unobstructedly       operator.
and a certain minimum gas transfer is warranted. If there is a danger of
operation against a closed inlet or outlet for more than a few seconds,    The maintenance instructions shall be observed.
a vacuum or pressure relief valve, respectively, shall be provided. In     Prior to handling the side channel blower these operating instructions
case of doubt seek advice from your Busch representative!                  shall be read and understood. If anything remains to be clarified
The maximum allowed back pressure of the side channel blower is            please contact your Busch representative!
1 bar (g). By means of process control and/or pressure relief valves it
must be made sure that the maximum allowed back pressure will not          Safety Notes
be exceeded.
                                                                           The side channel blower has been designed and manufactured accord-
                                                                           ing to the state-of-the-art. Nevertheless, residual risks may remain.
Principle of Operation                                                     These operating instructions inform about potential hazards where ap-
The side channel blower works on the impulse principle, i.e. kinetic en-   propriate. Safety notes are tagged with one of the keywords DANGER,
ergy is transferred from the rotor to the medium agent be pumped and       WARNING and CAUTION as follows:
then is converted into pressure.
For the two stage version:                                                           DANGER_a
2 stages, both working on the principle described above, are installed
                                                                            Disregard of this safety note will always lead to accidents with fa-
in line in order to achieve a better ultimate/differential pressure.
                                                                            tal or serious injuries.
The side channel blower compresses the inlet gas absolutely oil-free.
A lubrication of the pump chamber is neither necessary nor allowed.
                                                                                     WARNING_a
Cooling                                                                     Disregard of this safety note may lead to accidents with fatal or se-
The side channel blower is cooled by                                        rious injuries.
–    radiation of heat from the surface of the side channel blower
–    the air flow from the fan wheel of the drive motor                              CAUTION_a
–    the conveyed gas
                                                                            Disregard of this safety note may lead to accidents with minor inju-
On/off Switch                                                               ries or property damage.
The side channel blower comes without on/off switch. The control of
the side channel blower is to be provided in the course of installation.
                                                                           Noise Emission
                                                                           For the sound pressure level in free field according to DIN 45635,
                                                                           part 13 see “Technical Data”.
● Attach lifting gear securely to the eyebolt on the cylinder              Risk of damage or destruction of the side channel blower and ad-
                                                                           joining plant components!
● Attach the lifting gear to a crane hook with safety latch
● Lift the side channel blower with a crane                                Risk of injury!
In case the side channel blower was bolted to a pallet or a base plate:
                                                                           The installation prerequisites must be complied with.
    ◆ Remove the stud bolts from the rubber feet
                                                                          ● Make sure that the integration of the side channel blower is carried
                                                                            out such that the essential safety requirements of the Machine Di-
                                                                            rective 98/37/EC are complied with (in the responsibility of the de-
                                                                            signer of the machinery into which the side channel blower is to be
                                                                            incorporated; see also the note in the EC-Declaration of Confor-
                                                                            mity)
                                                                            Discharge Connection
                                                                            In case of vacuum operation:
                                                                            The following guidelines for the discharge line do not apply, if the inlet
                                                                            air is discharged to the environment right at the side channel blower.
● Make sure that the mounting base is even                                  ● Make sure that the discharge line fits to the outlet connection (d)
                                                                              of the side channel blower
● Make sure that in order to warrant a sufficient cooling there will be
  a clearance of minimum 0.1 m between the side channel blower              In case of using a pipe:
  and nearby walls
                                                                                ◆ Make sure that the pipe will cause no stress on the side
In case of mounting with the drive motor in the uppermost position:               channel blower‘s connection, if necessary use bellows
    ◆ Make sure that there will be a clearance of minimum 20 mm             ● Make sure that the line size of the discharge line over the entire
      (up to construction size 200) or 30 mm (as of construction size         length is at least as large as the side channel blower outlet
      310), respectively, between the cover (2.030) and the floor
                                                                            In case of very long discharge lines it is prudent to use larger line sizes
● Make sure that no temperature sensitive parts (plastics, wood,            in order to avoid a loss of efficiency. Seek advice from your Busch
  cardboard, paper, electronics) will touch the surface of the side         representative!
  channel blower
                                                                            ● Make sure that the discharge line either slopes away from the side
● Make sure that the installation space or location is vented such            channel blower or provide a liquid separator or a drip leg with a
  that a sufficient cooling of the side channel blower is warranted           drain cock, so that no liquids can back up into the side channel
                                                                              blower
Vacuum operation:
● In order to relieve excess vacuum or to limit the air flow use vent
  valves. Do not control the vacuum or the flow by throttling of suc-
  tion or discharge lines. Conveying bypass air will let the side
  channel blower run cooler and draw less power.
Pressure operation:
● In order to relieve excess pressure or to limit the air flow use bleed
  valves. Do not control the pressure or the flow by throttling of suc-
  tion or pressure lines. Bleeding excess air will let the side channel
  blower run cooler and draw less power.
                                                                           Star connection (high voltage):
Mounting
● Make sure that the “Installation Prerequisites” are complied with
● Fasten the side channel blower at its location
Connecting Electrically
WARNING_ab
                                                                           Connecting Lines/Pipes
                                                                           ● Connect the suction line
                                                                           ● Connect the discharge line
                                                                           or
                                                                           ● Connect the pressure line
                                                                           ● Make sure that all provided covers, guards, hoods etc. are
                                                                             mounted
Operation Notes                                                             During operation the surface of the side channel blower may reach
                                                                            temperatures of more than 70 °C.
Application
                                                                            Risk of burns!!
           CAUTION_a                                                       ● Prior to disconnecting lines make sure the lines are vented to at-
                                                                             mospheric pressure
 The side channel blower is designed for operation under the condi-
 tions described below.                                                    Maintenance Schedule
 In case of disregard risk of damage or destruction of the side            NOTE: The maintenance intervals depend very much on the individual
 channel blower and adjoining plant components!                            operating conditions. The intervals given below shall be considered as
                                                                           starting values which should be shortened or extended as appropriate.
 Risk of injury!                                                           Every 6 months:
 The side channel blower must only be operated under the condi-            ● Make sure that the housing is free from dust and dirt, clean if nec-
 tions described below.                                                      essary
                                                                           ● Make sure that the side channel blower is switched off and locked
The side channel blower is intended for
                                                                             against inadvertent switching on
–    the suction
                                                                           ● Clean the fan cowling, the fan wheel, ventilation grilles and the
–    the compression                                                         cooling fins
of                                                                         Every 2000 operating hours:
–    air and other non-aggressive, non-toxic and non-explosive gases       In case an inlet filter is installed:
The gas shall be free from vapours that would condensate under the             ◆ Clean (with pressurised air) or replace the inlet filter
temperature and pressure conditions inside the side channel blower.
                                                                           In case an inlet screen is installed:
The side channel blower is suitable for continuous operation, provided
that the housing can transmit heat to the environment unobstructedly           ◆ Clean the inlet screen
and a certain minimum gas transfer is warranted. If there is a danger of
operation against a closed inlet or outlet for more than a few seconds,
a vacuum or pressure relief valve, respectively, shall be provided. In     Overhaul
case of doubt seek advice from your Busch representative!
The maximum allowed back pressure of the side channel blower is                        CAUTION_a
1 bar (g). By means of process control and/or pressure relief valves it
must be made sure that the maximum allowed back pressure will not           In order to achieve best efficiency and a long life the side channel
be exceeded.                                                                blower was assembled and adjusted with precisely defined toler-
                                                                            ances.
                      CAUTION_ac                                            This adjustment will be lost during dismantling of the side channel
                                                                            blower.
 During operation the surface of the side channel blower may reach
 temperatures of more than 70 °C.                                           It is therefore strictly recommended that any dismantling of the side
                                                                            channel blower that is beyond of what is described in this manual
 Risk of burns!!                                                            shall be done by the Busch service.
 Secure the side channel blower against contact during operation, let
 it cool down prior to a required contact or wear heat protection                                                          DANGER_age32
 gloves.
                                                                            In case the side channel blower conveyed gases contaminated with
                                                                            foreign materials which are dangerous to health, harmful material
                      CAUTION_a4                                            can reside in pores, gaps and internal spaces of the side channel
                                                                            blower.
 Depending on the construction size the side channel blower may
 emit noise of high intensity.                                              Danger to health during dismantling of the side channel blower.
 Depending on the operating state the side channel blower may emit          Danger to environment.
 noise in a narrow band.
                                                                            Prior to shipping the side channel blower shall be decontaminated
 Risk of damage to the hearing.                                             as good as possible and the contamination status shall be stated in
                                                                            a “Declaration of Contamination” (form downloadable from
 Persons staying in the vicinity of the side channel blower over ex-        www.busch-vacuum.com).
 tended periods shall wear ear protection.
                                                                           Busch service will only accept side channel blowers that come with a
● Make sure that all provided covers, guards, hoods etc. remain            completely filled in and legally binding signed “Declaration of Contam-
  mounted                                                                  ination” (form downloadable from www.busch-vacuum.com).
● Make sure that protective devices will not be disabled
Recommissioning
● Observe the chapter “Installation and Commissioning”
Danger to environment.
Spare Parts
The bearings (1.007, 6.008) are intended as spare parts. Commercially
available standard parts are to be purchased on the open market. If an
overhaul requires parts other than bearings or standard parts your
Busch representative will clarify whether an overhaul is economic or a
replacement side channel blower should be considered.
NOTE: When ordering spare parts or accessories always quote the type
and the serial no. of the side channel blower (data on the nameplate).
 Electrical installation works must only be executed by qualified personnel that knows and observes the following regulations:
 - IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
 - IEC-Report 664 or DIN VDE 0110,
 - VBG 4 or corresponding national accident prevention regulation.
CAUTION_ac
During operation the surface of the side channel blower may reach temperatures of more than 70 °C.
Risk of burns!!
Let the side channel blower cool down prior to a required contact or wear heat protection gloves.
 The side channel blower does not reach the      Vacuum operation:                                   Check the hose or pipe connections for possi-
 usual pressure                                                                                      ble leak
                                                  The vacuum system or suction line is not
 The drive motor draws a too high current
                                                  leak-tight
 (compare with initial value after commissio-
 ning)                                           Pressure operation:
Vacuum operation:                                 The pressure system or pressure line is not
                                                  leak-tight
 Evacuation of the system takes too long
Pressure operation:
 Filling the system takes too long
 Building up pressure in the system takes too
 long
In case an inlet filter is installed: Clean or replace the inlet filter, respectively
Internal parts worn or damaged Repair the side channel blower (Busch service)
 The gas conveyed by the side channel blower      Process components evaporating under vacu-         Check the process, if applicable
 smells displeasing                               um
 The side channel blower does not start           The drive motor is not supplied with the cor-      Supply the drive motor with the correct volt-
                                                  rect voltage or is overloaded                      age
                                                  The drive motor starter overload protection is     Compare the trip level of the drive motor
                                                  too small or trip level is too low                 starter overload protection with the data on
                                                                                                     the nameplate, correct if necessary
                                                                                                     In case of high ambient temperature: set the
                                                                                                     trip level 5 percent above the nominal drive
                                                                                                     motor current
Version with alternating current motor: Repair the drive (Busch service)
                                                  The connection cable is too small or too long    Use sufficiently dimensioned cable
                                                  causing a voltage drop at the side channel
                                                  blower
                                                  The side channel blower or the drive motor is    Make sure the drive motor is disconnected
                                                  blocked                                          from the power supply
                                                                                                   Remove the fan cover
                                                                                                   Try to turn the drive motor with the side
                                                                                                   channel blower by hand
                                                                                                   If the side channel blower is blocked:
                                                                                                   Repair the side channel blower (Busch service)
The drive motor is defective Replace the drive motor (Busch service)
 The side channel blower is blocked               Solid foreign matter has entered the side        Repair the side channel blower (Busch service)
                                                  channel blower                                   Make sure the suction line is equipped with a
                                                                                                   screen
                                                                                                   If necessary additionally provide a filter
                                                  Version with three-phase motor:                  Repair the side channel blower (Busch service)
                                                                                                   When connecting the side channel blower
                                                  The side channel blower was run in the wrong
                                                                                                   make sure the side channel blower will run in
                                                  direction
                                                                                                   the correct direction (see “Installation”)
 The side channel blower starts, but labours or   Loose connection(s) in the drive motor termi-    Check the proper connection of the wires
 runs noisily or rattles                          nal box                                          against the connection diagram
 The drive motor draws a too high current         Version with three-phase-motor:                  Tighten or replace loose connections
                                                  Not all drive motor coils are properly connec-
                                                  ted
                                                  The drive motor operates on two phases only
                                                  Foreign objects in the side channel blower       Repair the side channel blower (Busch service)
                                                  Stuck bearings
The side channel blower runs very noisily Defective bearings Repair the side channel blower (Busch service)
 The side channel blower runs very hot            Insufficient air ventilation                     Make sure that the cooling of the side channel
                                                                                                   blower is not impeded by dust/dirt
                                                                                                   Clean the fan cowling, the fan wheel, ventila-
                                                                                                   tion grilles and the cooling fins
                                                                                                   Install the side channel blower in a narrow
                                                                                                   space only if sufficient ventilation is ensured
                                                  Mains frequency or voltage outside tolerance     Provide a more stable power supply
                                                  range
Manufacturer