CO2 – SLAB NEW DESIGN (1 – 5 kW)
Slab Design Improvement Presentation 06_06_14
Autoliv, MX
E. Serrano RSM Rofin-Inc. Plymouth, Michigan USA
New…: Delivery from 3rd February 2014
   Laser head               Reduced gas consumption due to 7 days gas
                             exchange intervals (DC 010 …. DC 050)
                            Shutter unit
                                 Improved positioning laser
                                 Optical safe design, Laser class 1 without housing,
                                  certification of safety control functionality
                            Designed for module integration
   Cabinet                    45% smaller footprint due to wall mountability (standard)
                              New RCU based control
                              Modular design
                              New Interface
                                 Improved safety
                                 Compatible to other MACRO products
PMU: SLAB 2014 17.9.2013                                                                2
   CO2 SLAB Laser: Laser head
                                         Beam
                                         dump
                               Laser
                               Beam
                                              Operating
                                            Status: Closed
 Laser class 1
                               Bending
 Improved positioning laser   Mirror
                                          Laser
                                          Diode
   PMU: SLAB 2014 17.9.2013                       3
New Standard Cabinet
  Cabinet
                              Wall mountable
                              Access from front side only
                              Modular design
                              45% reduced foot print
                           Footprint: Comparison
                                        NEW                  OLD
PMU: SLAB 2014 17.9.2013                                           4
    New Control
                                RCU based
       Control
                                Ethernet User Interface:
                                 Handheld, touch panel, PC/windows based
                                 system with ROFIN software.
                                Extended warning and error messages
                                Extended log and history listing
Software (PC/Touchpanel)
                                Get files back-up function
                                Extended E-Service possibilities
                                New System Interface
                                    24 V DC channel circuit
                                    Compatible to FL
     handheld                       2 - channel safety
                                    Improved Field bus (EtherCAT)
                                Improved pulse regulating
    PMU: SLAB 2014 17.9.2013                                          5
       Laser Software (standard)
 Lasers are delivered with an USB flash drive
  containing the laser software
 The software requires
       PC Hardware (i.e.: system PC)
       Windows 7 or XP
        .net framework 2.0
       Ethernet connection to the laser
       Screen resolution and size of 800x600 pixel
PMU: SLAB 2014 17.9.2013                              6
        HMI: (options)
 Optional available is
       Handheld (KEBA)
                     or
       Cabinet touch panel
               • Standard Cabinet only
PMU: SLAB 2014 17.9.2013                 7
New: improved pulse regulating
                           regulator
                           2 Hz
                           Analog output
                           Power sensor
                           Power setting
                                           Ramping
                           2000 Hz
PMU: SLAB 2014 17.9.2013                             8
Summary
      Laser head
         •    Reduced gas consumption
         •    Shutter Unit
         •    Optical safe design
         •    Improved pulse power regulation
      Laser cabinet
         •    Reduced footprint (standard)
         •    New RCU based control
         •    Modular design
         •    New Interface
      New Control (RCU):
         •    Common Control framework for all Rofin Lasers
         •    Common GUI for all MACRO Lasers
         •    Standardized interfaces
      New Options:
         •    Handheld terminals
         •    Touch panel (only for DC standard!)
         •    Emergency stop button
      GUI:
         •    Different Login levels (viewer …. service)
         •    Backup functionality; data loading
         •    Error history, detailed error messages
         •    Data visualization
         •    Pulse and ramping programs compatible with existing products
                                                     …
PMU: SLAB 2014 17.9.2013                                                     9
                           Thank you for your attention.
                                    www.rofin.com