10 Sustainable Sites 14 Points
Y Prereq 1 Construction Activity Pollution Prevention Required Required
1 Credit 1 Site Selection 1 1
1 Credit 2 Development Density & Community Connectivity 1 5
Credit 3 Brownfield Redevelopment 1 1
1 Credit 4.1 Alternative Transportation, Public Transportation Access 1 6
1 Credit 4.2 Alternative Transportation, Bicycle Storage & Changing Rooms 1 1
1 Credit 4.3 Alternative Transportation, Low-Emitting & Fuel-Efficient Vehicles 1 3
1 Credit 4.4 Alternative Transportation, Parking Capacity 1 2
1 Credit 5.1 Site Development, Protect or Restore Habitat 1 1
1 Credit 5.2 Site Development, Maximize Open Space 1 1
Credit 6.1 Stormwater Design, Quantity Control 1 1
Credit 6.2 Stormwater Design, Quality Control 1 1
1 Credit 7.1 Heat Island Effect, Non-Roof 1 1
1 Credit 7.2 Heat Island Effect, Roof 1 1
Credit 8 Light Pollution Reduction 1 1
Yes ? No
4 Water Efficiency 5 Points
Required
1 Credit 1.1 Water Efficient Landscaping, Reduce by 50% 1 2
1 Credit 1.2 Water Efficient Landscaping, No Potable Use or No Irrigation 1 2
Credit 2 Innovative Wastewater Technologies 1 2
1 Credit 3.1 Water Use Reduction, 20% Reduction 1 2
1 Credit 3.2 Water Use Reduction, 30% Reduction 1 2
8 Energy & Atmosphere 17 Points
Y Prereq 1 Fundamental Commissioning of the Building Energy Systems Required
Y Prereq 2 Minimum Energy Performance Required
Y Prereq 3 Fundamental Refrigerant Management Required
6 Credit 1 Optimize Energy Performance 1 to 10
10.5% New Buildings or 3.5% Existing Building Renovations 1
14% New Buildings or 7% Existing Building Renovations 2
17.5% New Buildings or 10.5% Existing Building Renovations 3
21% New Buildings or 14% Existing Building Renovations 4
24.5% New Buildings or 17.5% Existing Building Renovations 5
6 28% New Buildings or 21% Existing Building Renovations 6
31.5% New Buildings or 24.5% Existing Building Renovations 7
35% New Buildings or 28% Existing Building Renovations 8
38.5% New Buildings or 31.5% Existing Building Renovations 9
42% New Buildings or 35% Existing Building Renovations 10
Credit 2 On-Site Renewable Energy 1 to 3
2.5% Renewable Energy 1
7.5% Renewable Energy 2
12.5% Renewable Energy 3
Credit 3 Enhanced Commissioning 1
1 Credit 4 Enhanced Refrigerant Management 1
1 Credit 5 Measurement & Verification 1
Credit 6 Green Power 1
continued…
Yes ? No
3 Materials & Resources 13 Points
Y Prereq 1 Storage & Collection of Recyclables Required
Credit 1.1 Building Reuse, Maintain 75% of Existing Walls, Floors & Roof 1
Credit 1.2 Building Reuse, Maintain 100% of Existing Walls, Floors & Roof 1
Credit 1.3 Building Reuse, Maintain 50% of Interior Non-Structural Elements 1
Credit 2.1 Construction Waste Management, Divert 50% from Disposal 1
Credit 2.2 Construction Waste Management, Divert 75% from Disposal 1
Credit 3.1 Materials Reuse, 5% 1
Credit 3.2 Materials Reuse,10% 1
1 Credit 4.1 Recycled Content, 10% (post-consumer + ½ pre-consumer) 1
Credit 4.2 Recycled Content, 20% (post-consumer + ½ pre-consumer) 1
1 Credit 5.1 Regional Materials, 10% Extracted, Processed & Manufactured Regionally 1
1 Credit 5.2 Regional Materials, 20% Extracted, Processed & Manufactured Regionally 1
Credit 6 Rapidly Renewable Materials 1
10 Indoor Environmental Quality 15 Points
Y Prereq 1 Minimum IAQ Performance Required
Y Prereq 2 Environmental Tobacco Smoke (ETS) Control Required
Credit 1 Outdoor Air Delivery Monitoring 1
1 Credit 2 Increased Ventilation 1
1 Credit 3.1 Construction IAQ Management Plan, During Construction 1
1 Credit 3.2 Construction IAQ Management Plan, Before Occupancy 1
Credit 4.1 Low-Emitting Materials, Adhesives & Sealants 1
Credit 4.2 Low-Emitting Materials, Paints & Coatings 1
Credit 4.3 Low-Emitting Materials, Carpet Systems 1
Credit 4.4 Low-Emitting Materials, Composite Wood & Agrifiber Products 1
1 Credit 5 Indoor Chemical & Pollutant Source Control 1
1 Credit 6.1 Controllability of Systems, Lighting 1
1 Credit 6.2 Controllability of Systems, Thermal Comfort 1
1 Credit 7.1 Thermal Comfort, Design 1
1 Credit 7.2 Thermal Comfort, Verification 1
1 Credit 8.1 Daylight & Views, Daylight 75% of Spaces 1
1 Credit 8.2 Daylight & Views, Views for 90% of Spaces 1
Yes ? No
4 Innovation & Design Process 5 Points
1 Credit 1.1 Innovation in Design: Provide Specific Title 1
1 Credit 1.2 Innovation in Design: Provide Specific Title 1
1 Credit 1.3 Innovation in Design: Provide Specific Title 1
Credit 1.4 Innovation in Design: Provide Specific Title 1
1 Credit 2 LEED® Accredited Professional 1
Yes ? No
39 Project Totals (pre-certification estimates) 69 Points
Certified: 26-32 points, Silver: 33-38 points, Gold: 39-51 points, Platinum: 52-69 points
INDICADOR EFICIENTE
CONSUMO UNIDAD IND. PROMEDIO BUENAS PRÁCTICAS VALOR TIPICO USO EXCESIVO EDIFICIO TRANSOCEANICA
ENERGIA KWH/M2 AÑO 180,77 165,36 185,95 203,07 35,01
CLIMATIZACION KWH/M2 AÑO 12,52
ILUMINACION KWH/M2 AÑO 11,97
OTROS KWH/M2 AÑO 10,52
CONSUMO TOTAL SEGÙN SIMULACION ENERGETICA 35,01 KWH/M2 AÑO
CONSUMO TOTAL SEGÚN POTENCIA INSTALADA 70,02 KWH/M2 AÑO
COSTO CONSTRUCCION
EDIFICIO CCU 28 UF/M2
EDIFICIO TRANSOCEANICA 40 UF/M2
DIFERENCIA TOTAL 12 UF/M2
FORMA COMPLEJA Y ET SIN RELACION A EFICIENCIA ENERGETICA 7 UF/M2
SISTEMAS PASIVOS Y ACTIVOS DE EFICIENCIA ENERGETICA 5 UF/M2
SOBREVALOR EE 5UF/M2 12.000 M2 60.000 UF TOTAL EDIFICIO
GASTO ANUAL DE ENERGIA PROMEDIO(180 KWH/M2 AÑO) PARA 12.000 M2 11.880 UF
GASTO ANUAL DE ENERGIA SEGÚN POTENCIA INSTALADA (70 KWH/M2 AÑO) PARA 12.000 M2 4.620 UF
DIFERENCIA 7.260 UF AL AÑO SOBREVALOR EQUIVALENTE A 8 AÑOS DE
GASTO ANUAL DE ENERGIA SEGÚN SIMULACION ENERGETICA (35 KWH/M2 AÑO) PARA 12.000 M2 2.310 UF
DIFERENCIA 9.570 UF AL AÑO SOBREVALOR EQUIVALENTE A 6 AÑOS DE
NOTAS: INCLUYE SOBREVALOR DE PRIMERA EXPERIENCIA EN CHILE
NO CONSIDERA EVENTUALES AUMENTOS DE COSTOS DE ENERGIA
NO CONSIDERA AUMENTO EN LA PRODUCTIVIDAD DE USUARIOS