100% found this document useful (1 vote)
590 views6 pages

Firefighting Protective Clothing Specs

This document provides specifications for a European standard firefighting suit. It lists the materials and layers that make up the suit, including an outer layer of Nomex and Kevlar fabrics, a moisture barrier membrane, and inner insulation layers. It also details features such as elbow/knee pads, a zipper, and radio pocket. Technical test results are provided showing the suit meets European standards for flame retardancy, strength, moisture resistance and other parameters. Drawings and certification documents confirm compliance with the EN469 fire protective clothing standard.

Uploaded by

Salwa Anggreani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
590 views6 pages

Firefighting Protective Clothing Specs

This document provides specifications for a European standard firefighting suit. It lists the materials and layers that make up the suit, including an outer layer of Nomex and Kevlar fabrics, a moisture barrier membrane, and inner insulation layers. It also details features such as elbow/knee pads, a zipper, and radio pocket. Technical test results are provided showing the suit meets European standards for flame retardancy, strength, moisture resistance and other parameters. Drawings and certification documents confirm compliance with the EN469 fire protective clothing standard.

Uploaded by

Salwa Anggreani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Fire Fighting Protective Clothing (Jacket and Trouser)

EUROPEAN STANDARD FIRE FIGHTING SUIT

For body protection, with flame retardant,


waterproof, breathable, heat insulation, anti-
static, strong marking performance and high
visibility.

SPECIFICATION
Item Name : Fire-fighting protective clothing (Jacket and Trouser)
Brand : JJXF
Model Number : ZFMH-JX D (DRD)
Structures
Outer layer : 62% Nomex (Meta-Aramid), 36% Kevlar (Para-Aramid) and 2% P140
(Anti-Static Carbon Fiber). 205g/m2 (6.05oz) Ripstop
Mid Layer / Moisture : Aramid non-woven spunlance laminated to breathable PTFE
Barrier membrane. 108g/m2
Inner layer / Thermal : 80% Nomex (Meta-Aramid), 20% Kevlar (Para-Aramid) quilted to
barrier layer and 50% Nomex (Meta-Aramid), 50% Lenzing Flame Retardant. 120g/m2
Comfortable layer
Auxiliary material & : 3M SCOTCHLITE Reflective Tape
Accessories R-45 Nomex (Meta-Aramid) + Chloroprene rubber coating. 450g/m2
Features :  Flame Retardant
 Water friction resistance
 Drag Rescue Device (DRD)
 Elbow / knee protection
 Quick Release Zipper
 Knit cuff
 Radio Pocket
 Velcro
Color : Khaki / Navy Blue / Red Orange
Certificate :  CE EN469:2005
 ISO-9001:2015
 ISO-14001:2015
 ISO-45001:2018
DRAWING
CE EN469 CERTIFICATE
TECHNICAL PARAMETERS
No. Item Standard Test Result
After flame time(s) ≤2 0
Warp- Damaged length(mm) ≤100 5
Wise Experimental phenomena No melting, no pass
Flame
dripping
Retardant
After flame time(s) ≤2 0
Property
Damaged length(mm) ≤100 4
Weft-Wise
Experimental phenomena No melting, no pass
dripping
Warp-Wise (N) ≥650 1173
Cutting force
Outer Weft-Wise (N) ≥650 1003
1
Layer Warp-Wise (N) ≥100 277.5
Tensile strength
Weft-Wise (N) ≥100 240.8
Moisture resistance (degree) ≥3 3
Shrinkage rate (%) ≤10 1.0
Thermal stability Experimental phenomena No significant change pass
on surface
Weight of unit area (g/㎡) 205±10 206
Wash anti-stain ≥3 4-5
Colour fastness
Water friction resistance ≥3 4-5
Hydrostatic pressure ≥50 >50
Oil resistance ≥3 4
Moisture ≥5000 6099
Breathable capacity (g/㎡, 24h)
2 Barrier
layer Shrinkage rate (%) ≤10 2.0
Thermal stability Experimental phenomena No significant change pass
on surface
After flame time(s) ≤2 0
Warp- Damaged length(mm) ≤100 48
Wise Experimental phenomena No melting, no pass
Flame
dripping
Retardant
Thermal After flame time(s) ≤2 0
Property
3 barrier Damaged length(mm) ≤100 41
Weft-Wise
layer Experimental phenomena No melting, no pass
dripping
Shrinkage rate (%) ≤10 1.0
Thermal stability Experimental phenomena No significant change pass
on surface
After flame time(s) ≤2 0
Warp- Damaged length(mm) ≤100 39
Wise Experimental phenomena No melting, no pass
Flame
dripping
Retardant
Comfort After flame time(s) ≤2 0
Property
4 al ble Damaged length(mm) ≤100 35
Weft-Wise
layer Experimental phenomena No melting, no pass
dripping
Shrinkage rate (%) ≤10 1.0
Thermal stability Experimental phenomena No significant change pass
on surface
5 Overall thermal protection performance TPP(cal/c㎡) ≥28 34
Warp-Wise (N) ≥650 917.8
6 Seam Tensile strength
Weft-Wise (N) ≥650 848.9
Flame After flame time(s) ≤2 0
Retardant Experimental phenomena No melting, no pass
Property dripping
no rupture,
wrinkling, distortion
Performance of washing-resistant pass
7 Reflective stripe phenomenon after
test
no rupture,
wrinkling, distortion
High and low temperature performance pass
phenomenon after
test
Flame
No melting, no
8 Sewing thread Retardant Experimental phenomena pass
dripping
Property
Flame
No melting, no
9 Metal parts Retardant Experimental phenomena pass
dripping
Property
unfolding time (s) ≤10 6
Drag Rescue Device Drag distance (m) ≥2.5 >2.5
10
(DRD) Tensile Warp-Wise (N) ≥7000 8373
strength Weft-Wise (N) ≥7000 8373
11 Stitch density top/blind stitch 12 stitching/3cm 13 stitching/3cm
12 Weight (kg) ≤3.5 2.88