HPL-Pipe Manifold Drg-Model

The document provides a list of equipment for a chilled water pipe manifold including ball valves, strainers, balancing valves, pressure gauges, temperature gauges, drain valves, and air vent valves. Pipe sizes are specified as 50 mm or 25 mm. A diagram shows the layout of the manifold piping and location of equipment connecting a chiller unit and air handling unit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
635 views1 page

HPL-Pipe Manifold Drg-Model

The document provides a list of equipment for a chilled water pipe manifold including ball valves, strainers, balancing valves, pressure gauges, temperature gauges, drain valves, and air vent valves. Pipe sizes are specified as 50 mm or 25 mm. A diagram shows the layout of the manifold piping and location of equipment connecting a chiller unit and air handling unit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

* M.

S C-CLASS PIPE WITH DULY INSULATED


LEGENDS DESCRIPTION QTY
in mm
BALL VALVE with extended stem 50 6
BV
handle
" Y " STRAINER 50 1
BV BALANCING VALVE 50 1
A
3-WAY VALVE WITH ACTUATOR 50 1
PG PRESSURE GAUGE - 2

MAIN HEADER

CHW SUPPLY

MAIN HEADER
CHW RETURN
- 2

FROM SUPPLY
TG TEMPERATURE GAUGE

TO RETURN
* M.S C-CLASS PIPE WITH DULY INSULATED
DRAIN VALVE 25 1
AIRVENT VALVE 25 1
AUTO AIRVENT
TEMPERATURE 25 NB BUTTERFLY /
GAUGE BALL VALVE

INSULATION
AIR
OUT

PIPE MANIFOLD

INSULATION
CHI
LLE PRESSURE
DW
ATE GAUGE
COI R
AHU - 01 AIR
I N
L 3-WAY
MIXING VALVE
BALANCING
VALVE

Y-STRAINER
DRAIN
VALVE

U-TRAP

CHILLED WATER COIL CONNECTION FOR AHU

CLIENT :
DESIGN : CHKD : APVD : 23-11-2015
DATE
HIGHER pharmatech Pvt. Ltd.
RAJU ANGADI RAJU ANGADI B.J.N RAO
Plot 46, KIADB Industrial Area, VindAir Engineers Pvt Ltd
SCALE N.T.S Harohalli Phase I, Kanakpura Taluk, No.96/A(1), 42nd Cross, 3rd Main,
Drg No:- VEPL/MANIFOLD/HPL/AHU-02 Ramanagara Dist, Karnataka 562112 8th Block, Jaya Nagar
BANGALORE - 560 082.INDIA.
TITLE: Ph: +91- 80 - 2663 7959
CONSULTANT :
Propound Pharma Consulting Pvt. Ltd. VINDAIR Email:info@vindair.com
CHILLED WATER PIPE ALL DIMENSIONS ARE IN MM
No.167, 4th Main, Judicial Layout,
Thalagattapura PO,
Kanakapura Main Road,
R e d e f i n e. . . s i m p l i c i t y
vindair@gmail.com
Web : www.vindair.com
MANIFOLD DRAWING UNLESS OTHERWISE SPECIFIED. BANGALORE - 560 062, Karnataka, India.
Email: cks@propoundpharma.com
Web : www.propoundpharma.com