Product data sheet
Specifications
                                            Harmony XVB, Illuminated unit for
                                            modular tower lights, plastic, green,
                                            Ø70, steady, integral LED, 24 V AC/
                                            DC
                                            XVBC2B3
                                                                                            Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product                 Harmony XVB Universal
Product or component type        Indicator bank
Beacon or indicator bank unit    Illuminated unit
type
Signalling type                  Steady
Mounting diameter                70 mm
Component name                   XVBC
Material                         Polycarbonate
Light source                     Integral LED, green
Bulb type                        Protected LED
[Us] rated supply voltage        24 V AC/DC
Complementary
Assembly style                   Customer assembly, up to 5 units
Connections - terminals          Screw clamp terminals, <= 1 x 1.5 mm² with cable end
[Ui] rated insulation voltage    250 V conforming to IEC 60947-1
Nominal voltage limit            0.85...1.1 Un conforming to IEC 60947-5-1
Current consumption              < 47 mA AC/DC
[Uimp] rated impulse withstand   4 kV conforming to IEC 60947-1
voltage
CAD overall width                70 mm
CAD overall height               63 mm
CAD overall depth                70 mm
Net weight                       0.15 kg
Environment
Pollution degree                 2
Product certifications            CCC
                                 EAC
                                 CSA C22-2 No 14
                                 UL 508
Standards                        EN/IEC 60947-5-1
Aug 25, 2022                                                                            1
Protective treatment           TC
Ambient air temperature for    -40…70 °C
storage
Ambient air temperature for    -25…50 °C
operation
Electrical shock protection    Class I on support tube conforming to IEC 61140
class                          Class II on base unit conforming to IEC 61140
IP degree of protection        IP65 on fixing base XVBZ0. conforming to IEC 60529
                               IP66 on base unit conforming to IEC 60529
NEMA degree of protection      Type 4X conforming to UL (indoor)
Packing Units
Unit Type of Package 1         PCE
Number of Units in Package 1   1
Package 1 Weight               137.4 g
Package 1 Height               79.6 mm
Package 1 width                80.67 mm
Package 1 Length               91.37 mm
Unit Type of Package 2         P06
Number of Units in Package 2   288
Package 2 Weight               53.66 kg
Package 2 Height               80.0 cm
Package 2 width                80.0 cm
Package 2 Length               60.0 cm
Unit Type of Package 3         S03
Number of Units in Package 3   36
Package 3 Weight               5.542 kg
Package 3 Height               30.0 cm
Package 3 width                30.0 cm
Package 3 Length               40.0 cm
Offer Sustainability
Sustainable offer status        Green Premium product
REACh Regulation               REACh Declaration
EU RoHS Directive              Pro-active compliance (Product out of EU RoHS legal scope)
                               EU RoHS Declaration
Mercury free                   Yes
RoHS exemption information     Yes
China RoHS Regulation          China RoHS declaration
Environmental Disclosure       Product Environmental Profile
WEEE                           The product must be disposed on European Union markets following specific waste collection and
                               never end up in rubbish bins
California proposition 65      WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is
                               known to the State of California to cause cancer and birth defects or other reproductive harm. For more
                               information go to www.P65Warnings.ca.gov
Contractual warranty
Warranty                       18 months
  2
                                                                                                              Aug 25, 2022
Product data sheet                                         XVBC2B3
Dimensions Drawings
Indicator Bank without “Flash” Discharge Tube Unit
Dimensions
Below drawing shows the minimum configuration of the product. Select the number of stages according to the product characteristics in order to
get b dimension.
(1)      Base unit XVBC21, to be ordered separately
(2)      Illuminated or audible signalling unit
(3)      Cover (supplied with XVBC21 base unit)
Number of illuminated or audible signalling units (no “flash”)                     b in mm                     b in in.
1                                                                                  138                         5.43
2                                                                                  201                         7.91
3                                                                                  264                         10.39
4                                                                                  327                         12.87
5                                                                                  390                         15.35
Aug 25, 2022                                                                                                                         3
Product data sheet                                        XVBC2B3
Dimensions Drawings
Indicator Bank with “Flash” Discharge Tube Unit
Dimensions
Below drawing shows the minimum configuration of the product. Select the number of stages according to the product characteristics in order to
get b dimension.
(1)       Base unit XVBC07, to be ordered separately
(2)       Illuminated or audible signalling unit
(3)       “Flash” unit, to be ordered separately
Number of illuminated or audible signalling units other than “flash” tube          b in mm                     b in in.
1                                                                                  295                         11.61
2                                                                                  358                         14.09
3                                                                                  421                         16.57
4                                                                                  484                         19.06
      4