0% found this document useful (0 votes)
365 views2 pages

Itaia Pti1000 Techdata

The document discusses a real resistance replicator and isolator device that can be used for galvanic isolation of resistance-based sensors and multiplying measuring systems on a single sensor. It has various models that provide different output options like multiple RTD outputs, RTD and current/voltage output, or current/voltage to RTD conversion. It offers high accuracy, intrinsic safety isolation, and compatibility with pulsed/multiplexed measurement systems.

Uploaded by

Asep Saepudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
365 views2 pages

Itaia Pti1000 Techdata

The document discusses a real resistance replicator and isolator device that can be used for galvanic isolation of resistance-based sensors and multiplying measuring systems on a single sensor. It has various models that provide different output options like multiple RTD outputs, RTD and current/voltage output, or current/voltage to RTD conversion. It offers high accuracy, intrinsic safety isolation, and compatibility with pulsed/multiplexed measurement systems.

Uploaded by

Asep Saepudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Real Resistance RTD Splitter/

Isolator PTi 1000 _DH/SH/XD/XS


High accuracy real resistance replicator & isolator PTi 1000_ is used for
galvanic isolation of resistance - based sensors and multiplying measuring
systems on a single sensor - i.e. RTD resistance splitter. Special, patented
design delivers high accuracy resistance output even when read on
pulsed or multiplex measuring systems.
Basic operation principle is resistance measurement, calculation and
resistance generation on two or more independent outputs. Mini OLED
display provides basic information on working mode, input resistance and
temperature correspondence for designated sensor. DIN rail mounted
housing is fitted for industry cabinet use.
For various applications a number of types are available: Full-Auto-range,
several Narrow-range types, RTD + Current & Voltage output, chained _DHf FEATURES
modules for multiple RTD outputs and Current/Voltage to RTD converter.
All with intrinsic safe galvanic separation on every port -see table below.  RTD / Resistance 2, 3, 4w input
 2 wire in-line-loop compensation
 2 channel RTD (DH, DHf) or RTD +
Current/Voltage output (SH)
with superb linearity
 Resistance out. 30Ω – 9,5 kΩ
 High accuracy /typically 0,02%
(Temp eff: 0,05°C /60°range @PT100)
 Pulsed / multiplex
measurement compatible
 No out-excitation current & pulse
duration limit (within max. load)
 PT100/1000, KTxx conversion
 Selectable Current / Voltage
output range (_SH _OLED)
* _DH/SH OLED type only
 Voltage/Current to RTD
Type codes: i.e. PTi 1000 DH x0 OLED eX resistance conversion (_XD,_XS)
Function Range & accuracy Display / [EEx ia]  Galvanic isolation on every port
Resistance 0 -10 k IN
OLED display
 Excellent EMC performance
DH / 30-9,5k  / -50....300°C ; ±0,05°C@PT100 _OLED
# digital IN ;
 With or without OLED display
DHf # 2x resistance (RTD) OUT Multi-sensor / conversion / auto-ranging / no display  10…30V AC or DC power supply

SH Resistance 0 -10 k IN ; x0 96-120  / -10....50°C; ±0,1°C @PT100


APPLICATIONS
1x resistance (RTD) OUT x1 92-158  / -20....150°C; ±0,2°C @PT100 / standard

 PT100/1000/RTD splitter - clone


92-213  / -20....300°C; ±0,4°C @PT100
 Sharing Temperature / Force /
1x 0/4-20mA, 0-10V OUT x2 _eX [EEx ia]

0/4 - 20mA, 0 -10V IN ; x3 960-1200  / -10....50°C; ±0,1°C @PT1000 Position sensors


1x resistance (RTD) OUT
 Sensor isolation & intrinsic
XS 920-1580  / -20....150°C; ±0,2°C @PT1000 safety separation (_Ex ia)
2x resistance (RTD) OUT x4
XD
 Ground-loop cancelation
//RTD simulation ; RTD from
current loop extraction//
X5 920-2130  / -20....300°C; ±0,4°C @PT1000  Intermediate temperature
control and monitor (OLED)
* Custom ranges available
 RTD sensor conversion
ITAIA d.o.o., Litostrojska 44/d, SI-1000 Ljubljana, Slovenia
T +386 1 514 18 00, F +386 1 514 18 04, E info@itaia.si | www.itaia.si  RTD resistance extraction from
Voltage / Current loop (_XD,_XS)
TECHNICAL SPECIFICATIONS
OVERALL DH/SH/XS/XD types _eX option DHf modules
Power supply 10 - 30 V AC or DC
Polarity reverse protection yes
Power consumption: average / peak < 1,2 W (OLED) / 2,5 W
Galvanic isolation - any port; capacitance > 500 VAC; < 300 pF 2500 VAC ; < 300 pF
Temperature range -30 ... +50° C
Protection degree IP20
Dimensions (W x H x D); weight; rail mounting 22 x 92 x 69 mm; 135 g; EN 60715 / 22 x 92 x 93 mm; 250g; EN 60715
Compliance CE, EN61010-1, EN61000-3/2,-6/1,3 Ex II3 [EEx ia]
RESISTANCE INPUT DIGITAL INPUT
Temperature sensor compatibility PT100/500/1000, Ni100, KT_xx
Connection 2/3/4 wire D-side bus
Loop resistance - 2w compensation < 50 Ω

Sensor excitation current < 0,65mA


Resolution; RTDeff@ PT100; PT500/1000,KT_ 16 bit; 0,03 °C; 0,01 °C
RESISTANCE OUTPUT
Connection 2/3/4 wire
Excitation current, max. load < 10 mA , 100 mW
Input to Output delay < 0,5 s
Pulsed/multiplex read compatible yes
Number of outputs 2 or 4
CURRENT / VOLTAGE OUTPUT(_SH) & INPUT(_XD,_XS)
Current IN & OUT; max. voltage IN 0 /4 - 20 mA selectable; max. 35 V
Voltage IN & OUT; max. load OUT 0 – 10V; max. 5 mA
DISPLAY
Type OLED 64x48 , blue
WORKING MODE
Auto OUT = IN i.e. PT100 IN / 2X PT100 OUT
x10 * OUT=10 x IN i.e. PT100 IN / 2X PT1000 OUT

/10 * OUT=IN / 10 i.e. PT1000 IN / 2X PT100 OUT


F-FIX * OUT = IN i.e. Fast response draft output
PT/KT ** PT100 / KT i.e. PT100 IN / 2X KT21 OUT
Release V1.7 ,date of issue 1.2019 Copyright: ITAIA d.o.o., Ljubljana, Slovenia

Input sensor -2 wire loop


2w Comp /
impedance compensation
* _DH/SH OLED only

ERROR LIMITS
Resistance DISPLAY Repetition INPUT to OUTPUT
range res. ; accuracy (Ω) Temp. res. ; accuracy (°C) res. ; accuracy (Ω) Temp. res. ; accuracy (°C)

0 Ω - 30 Ω 10 mΩ ; < ±0,1% ±1dig *not applied / *not applied

30 Ω - 80 Ω 10 mΩ ; < ±0,05% ±1dig *not applied 50 mΩ ; < ±0,5% ±1dig *not applied

80 Ω - 212 Ω 10 mΩ ; < ±0,02% ±1dig 0,1°C ; < ±0,1°C ±1dig (PT100 @ -50..300°C) 10 mΩ ; < ±0,02% ±1dig 0,01°C ; < ±0,1°C ±1dig (PT100 @ -50..300°C)

212 Ω - 650 Ω 10 mΩ ; < ±0,03% ±1dig *not applied 10 mΩ ; < ±0,05% ±1dig *not applied

650 Ω - 1kΩ 100 mΩ ; < ±0,03% ±1dig 0,1°C ; < ±0,1°C ±1dig (PT1000 @ -30..0°C) 20 mΩ ; < ±0,03% ±1dig 0,05°C ; < ±0,2°C ±1dig (PT1000 @ -30..0°C)

1 kΩ - 2,2 kΩ 100 mΩ ; < ±0,02% ±1dig 0,1°C ; < ±0,1°C ±1dig (PT1000 @ 0..300°C) 20 mΩ ; < ±0,02% ±1dig 0,05°C ; < ±0,2°C ±1dig (PT1000 @ 0..300°C)

2,2 kΩ - 9,5 kΩ 1 Ω ; < ±0,05% ±1dig *not applied 50 mΩ ; < ±0,2% ±1dig *not applied
PTi 1000 DH OLED data; % for r.v.; * applicable, accuracy not specified

PTi 1000 DH/DHf/SH/XD/XS | TECHNICAL SHEET Subject to change with no further notice due to technical updates.

You might also like