100% found this document useful (1 vote)
860 views1 page

DDEC II Boot Mode

To recalibrate or program a DDECII ECM, connect the ECM to enter boot mode by connecting terminals B3, C1, C2, E1, F2, G3, and H3 to specific points - B3 to ignition, C1 and C2 to the J1708 data link, E1 to a 3.9k resistor to ground, and F2, G3, and H3 to ground. To read data from the ECM without recalibration, disconnect power and the E1, F2, G3, and H3 connections, wait 5 seconds, and reconnect power.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
860 views1 page

DDEC II Boot Mode

To recalibrate or program a DDECII ECM, connect the ECM to enter boot mode by connecting terminals B3, C1, C2, E1, F2, G3, and H3 to specific points - B3 to ignition, C1 and C2 to the J1708 data link, E1 to a 3.9k resistor to ground, and F2, G3, and H3 to ground. To read data from the ECM without recalibration, disconnect power and the E1, F2, G3, and H3 connections, wait 5 seconds, and reconnect power.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

hi buddy, well to recalibrate or programing DDECII, the ecm should

stay in boot mode, to put the ecm in boot mode make the next bench
conecction....
B3 = Ignici?n
C1 = Data link J1708 (-)
C2 = Data link J1708 (+)
E1 = Connect one resistor of 3.9k to GND
F2, G3 y H3 = GND

remember this metod is to calibrate only, to read data from the


ecm disconecct the power, disconnect E1, F2, G3 and H3 wait 5
seconds then connect the power