0% found this document useful (0 votes)
146 views6 pages

eHYDRO SERIES

The document discusses Lubi pressure booster pump systems. It describes three series of pumps - LHP, LMF, and MH - which are used to maintain constant water pressure. The systems include a close-coupled pump, pressure tank, pressure switch, and other components. They are suitable for potable water applications and can provide sufficient pressure for homes and businesses. The document provides details on pump specifications, operating conditions, applications, and includes a selection chart to determine the appropriate system size.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views6 pages

eHYDRO SERIES

The document discusses Lubi pressure booster pump systems. It describes three series of pumps - LHP, LMF, and MH - which are used to maintain constant water pressure. The systems include a close-coupled pump, pressure tank, pressure switch, and other components. They are suitable for potable water applications and can provide sufficient pressure for homes and businesses. The document provides details on pump specifications, operating conditions, applications, and includes a selection chart to determine the appropriate system size.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

HYDRO SERIES

Pressure Booster Pumps


50 Hz

TM

Maintain constant pressure with LUBI HYDRO SERIES pressure pump

Pumping Solution
HYDRO PRESSURE BOOSTER PUMPS

INTRODUCTION FEATURES AND BENEFITS


The Lubi Hydro series are state-of-the-art designed  NSF Standard 61, CE/PED, WRAS, ACS, ISO:9001,
compact, automatic pressure booster pumps.
Gost, Evrazes approved
Lubi offers below series as pressure booster pump: pressure tank
 Easy installation
 Reliable and user friendly operation
1.) “LHP” SERIES PRESSURE BOOSTER PUMP  Adjustable pressure
It consist of our PCJ standard pump series. PCJ pumps are  Reliable constant pressure water supply
horizontal, single-stage, centrifugal, shallow-well self  Two part polyurethane, epoxy primed paint finish tank
priming jet pumps. Pumps have suction port above pump  Leak free, o-ring sealed air valve cap provided on tank
axis and radial discharge port. The pump is fitted with a  Corrosion resistant
maintenance-free, mechanical shaft seal.  Good air handling
 Reliable and robust construction
 Low noise level
2.) “LMF” SERIES PRESSURE BOOSTER PUMP
It consist of our MFHC standard pump series. MFHC pumps OPERATING CONDITIONS
are non-self priming, horizontal, multi-stage, centrifugal Flow range : Up to 10 m³/h
pumps. Pumps have suction port above pump axis and radial Max. working pressure : 10 bar
discharge port. The pump is fitted with a maintenance-free, Ambient temperature : Max. +50°C
mechanical shaft seal. Liquid temperature range: 0°C to +90°C
MOTOR
3.) “MH” SERIES PRESSURE BOOSTER PUMP
It consist of our MH standard pump series. MH pumps are Motor type : TEFC 2-pole motor
Ratings : 1 phase - 0.37 to 1.50 kW
non-self priming, horizontal, multi-stage, centrifugal pumps. Rated speed : 2900 rpm
Pumps have axial suction port and radial discharge port. The Enclosure class : IP 44
pump is fitted with a maintenance-free, mechanical shaft Insulation class :F
seal. Nominal voltage : 1 phase 230 V
(Tolerance +5% / -15%)
These systems are supplied as complete, preassembled and Supply frequency : 50 Hz
Duty / Rating : S1 / Continuous
factory tested systems including a close-coupled pump, Direction of rotation : Clockwise as seen from the motor rear end
bladder type pressure tank, pressure switch, pressure gauge
(or electronic switch), special connector and flexible pipe for APPLICATIONS
systems with pump over the tank. These pumps are suitable for liquids which are potable & rain
water other than thin, clean, non-aggressive, non-explosive,
These systems can provide sufficient water pressure for not containing solid particles or fibres.
modern domestic appliances to ensure sufficient water Pumps are designed for liquid transfer & pressure boosting
supply. Thus these systems are widely used in domestic systems in:
water applications to stabilize the pressure in the system and  Households, commercial complexes
avoid the pump cycling on and off every time a tap is opened  Gardens,
somewhere in the house.  Agriculture
 Horticulture
 Small industries
These systems can work according to the any decrease or  Car washing
increase of pressure, the pressure switch determines when  Cooling systems
the pump will start or stop.  Drawing water out a well.
FUNCTION
The booster set cuts in and out by means of the pressure switch. When water is tapped from the system, it will at first be tapped from
the pressure tank, see below fig. Then the pressure falls to the preset cut-in pressure and the pump will cut in. When the water
consumption drops, the discharge pressure increases and the pump cuts out when the pressure reaches the preset cut-out pressure
of the pressure switch.
1 Air valve 2 3 4
Pressure tank Air @ 3.5 bar Air @ 3 bar

Air @ 2 bar Air @ 2.7 bar

Water
Water @ 3.5 bar
Water
WATER Pressure WATER WATER WATER
OFF switch OFF OFF ON

From PUMP From PUMP From PUMP From PUMP


Water OFF Water ON Water ON Water OFF
source source source source

INITIAL CONDITION PUMP IS ACTIVATED BY PUMP RUNS UNTIL TANK WATER FLOWS FROM TAP
PRESSURE SWITCH IS FILLED WITH WATER DUE TO TANK PRESSURE
Note: This is a typical pressure booster pump system layout.
Pressures shown in above figures are approximate.
HYDRO PRESSURE BOOSTER PUMPS

SELECTION CHART

SUCTION DISCHARGE TANK DRAW DOWN PRESSURE SETTING APPROX.


SYSTEM MOTOR POWER PUMP SIZE SIZE TANK TYPE OF CAPACITY CAPACITY RANGE Q MAX.
SUITABLE
TYPE kW HP TYPE [inch] [inch] MODEL TANK [litres] [litres] [bar] [kgf/cm²] [lit/hr] FOR
LHP 1B 0.37 0.50 PCJ-051CC 1 1 LHI-8 in-line 8 3 1.4 - 3.4 1.4 - 3.4 3250 1 bathrooms
LHP 1A 0.37 0.50 PCJ-051CC 1 1 LHI-24 in-line 24 9 1.4 - 3.4 1.4 - 3.4 3250 2 bathrooms
LHP 2A 0.37 0.50 PCJ-051CC 1 1 LHI-35 in-line 35 13 1.4 - 3.4 1.4 - 3.4 3250 4 bathrooms
LHP 3A 0.75 1.00 PCJ-101CC 1 1 LHI-24 in-line 24 9 2.1 - 3.9 2.1 - 3.9 4000 3 bathrooms
LHP 3B 0.75 1.00 PCJ-101CC 1 1 LHI-35 in-line 35 13 2.1 - 3.9 2.1 - 3.9 4000 5 bathrooms
LHP 4A 0.75 1.00 PCJ-101CC 1 1 LHH-60 Horizontal 60 20 2.1 - 3.9 2.1 - 3.9 4000 6 bathrooms
LHP 6A 0.75 1.00 PCJ-101CC 1 1 LHH-80 Horizontal 80 29 2.1 - 3.9 2.1 - 3.9 4000 8 bathrooms

SUCTION DISCHARGE TANK DRAW DOWN PRESSURE SETTING APPROX.


SYSTEM MOTOR POWER PUMP SIZE SIZE TANK TYPE OF CAPACITY CAPACITY RANGE Q MAX.
SUITABLE
TYPE kW HP TYPE [inch] [inch] MODEL TANK [litres] [litres] [bar] [kgf/cm²] [lit/hr] FOR
LMF 1A 0.75 1.00 MFHC-101DD 1¼ 1¼ LHI-24 in-line 24 9 2.1 - 3.9 2.1 - 3.9 7500 3 bathrooms
LMF 2A 0.75 1.00 MFHC-101DD 1¼ 1¼ LHI-35 in-line 35 13 2.1 - 3.9 2.1 - 3.9 7500 5 bathrooms
LMF 3A 0.75 1.00 MFHC-101DD 1¼ 1¼ LHH-60 Horizontal 60 20 2.1 - 3.9 2.1 - 3.9 7500 6 bathrooms
LMF 4A 1.10 1.50 MFHC-151DD 1¼ 1¼ LHI-35 in-line 35 13 2.4 - 4.8 2.4 - 4.8 8700 6 bathrooms
LMF 5A 1.10 1.50 MFHC-151DD 1¼ 1¼ LHH-60 Horizontal 60 20 2.4 - 4.8 2.4 - 4.8 8700 7 bathrooms
LMF 6A 1.10 1.50 MFHC-151DD 1¼ 1¼ LHH-80 Horizontal 80 29 2.4 - 4.8 2.4 - 4.8 8700 8 bathrooms
LMF 7A 1.50 2.00 MFHC-201DD 1¼ 1¼ LHH-60 Horizontal 60 20 2.8 - 5.6 2.8 - 5.6 9900 8 bathrooms
LMF 8A 1.50 2.00 MFHC-201DD 1¼ 1¼ LHH-80 Horizontal 80 29 2.8 - 5.6 2.8 - 5.6 9900 10 bathrooms

SUCTION DISCHARGE TANK DRAW DOWN PRESSURE SETTING APPROX.


SYSTEM MOTOR POWER PUMP SIZE SIZE TANK TYPE OF CAPACITY CAPACITY RANGE Q MAX.
SUITABLE
TYPE kW HP TYPE [inch] [inch] MODEL TANK [litres] [litres] [bar] [kgf/cm²] [lit/hr] FOR
MH2 1B 0.55 0.75 MH2-40 1 1 LHI-8 in-line 8 3 1.8 - 3.0 1.8 - 3.0 3300 1 bathrooms
MH2 1A 0.55 0.75 MH2-40 1 1 LHI-24 in-line 24 9 1.8 - 3.0 1.8 - 3.0 3300 1-2 bathrooms
MH2 2A 0.75 1.00 MH2-50 1 1 LHI-24 in-line 24 9 2.1 - 3.7 2.1 - 3.7 3300 2 bathrooms
MH2 3A 0.75 1.00 MH2-50 1 1 LHI-35 in-line 35 13 2.1 - 3.7 2.1 - 3.7 3300 2-3 bathrooms
MH2 4A 0.75 1.00 MH2-50 1 1 LHH-60 Horizontal 60 20 2.1 - 3.7 2.1 - 3.7 3300 3 bathrooms
MH2 7A 0.75 1.00 MH2-60 1 1 LHI-35 in-line 35 13 2.5 - 4.5 2.5 - 4.5 3300 3-4 bathrooms
MH2 8A 0.75 1.00 MH2-60 1 1 LHH-60 Horizontal 60 20 2.5 - 4.5 2.5 - 4.5 3300 3-4 bathrooms
MH4 1B 0.55 0.75 MH4-30 1¼ 1 LHI-8 in-line 8 3 1.2 - 2.2 1.2 - 2.2 7500 1-2 bathrooms
MH4 1A 0.55 0.75 MH4-30 1¼ 1 LHI-24 in-line 24 9 1.2 - 2.2 1.2 - 2.2 7500 2 bathrooms
MH4 2A 0.75 1.00 MH4-40 1¼ 1 LHI-24 in-line 24 9 1.4 - 2.8 1.4 - 2.8 7500 3 bathrooms
MH4 3A 0.75 1.00 MH4-40 1¼ 1 LHI-35 in-line 35 13 1.4 - 2.8 1.4 - 2.8 7500 4 bathrooms
MH4 4A 0.75 1.00 MH4-40 1¼ 1 LHH-60 Horizontal 60 20 1.4 - 2.8 1.4 - 2.8 7500 5 bathrooms
MH4 5A 0.93 1.25 MH4-50 1¼ 1 LHH-60 Horizontal 60 20 1.6 - 3.5 1.6 - 3.5 7500 7 bathrooms
MH4 6A 0.93 1.25 MH4-50 1¼ 1 LHH-80 Horizontal 80 29 1.6 - 3.5 1.6 - 3.5 7500 8 bathrooms
MH4 7A 1.10 1.50 MH4-60 1¼ 1 LHH-60 Horizontal 60 20 2.0 - 4.0 2.0 - 4.0 7500 8 bathrooms
MH4 8A 1.10 1.50 MH4-60 1¼ 1 LHH-80 Horizontal 80 29 2.0 - 4.0 2.0 - 4.0 7500 10 bathrooms
HYDRO PRESSURE BOOSTER PUMPS

DIMENSIONS & WEIGHT

b
DNd

DNs

c
c

DNd

DNs
a

b d

HORIZONTAL IN-LINE
SYSTEM MOTOR POWER TYPE OF DNs DNd DIMENSIONS [mm] GROSS WEIGHT [kg] GROSS VOLUME [m³]
TYPE kW HP TANK [BSP] [BSP] a b c d PUMP TANK PUMP TANK
LHP 1B 0.37 0.50 in-line 1” 1” 202 313 603 410 21.1 0.1002
LHP 1A 0.37 0.50 in-line 1” 1” 290 447 737 410 23.0 0.1002
LHP 2A 0.37 0.50 in-line 1” 1” 318 481 771 410 14.0 7.0 0.0530 0.0620
LHP 3A 0.75 1.00 in-line 1” 1” 290 447 762 435 29.8 0.1118
LHP 3B 0.75 1.00 in-line 1” 1” 318 481 796 435 21.0 7.0 0.0530 0.0620
LHP 4A 0.75 1.00 Horizontal 1” 1” 424 530 845 435 21.0 11.4 0.0530 0.0900
LHP 6A 0.75 1.00 Horizontal 1” 1” 424 726 1041 435 21.0 16.1 0.0530 0.1300

d a

DNd

DNs
b

DNd
c

DNs
a

b d

HORIZONTAL IN-LINE
SYSTEM MOTOR POWER TYPE OF DNs DNd DIMENSIONS [mm] GROSS WEIGHT [kg] GROSS VOLUME [m³]
TYPE kW HP TANK [BSP] [BSP] a b c d PUMP TANK PUMP TANK
LMF 1A 0.75 1.00 in-line 1¼” 1¼” 290 447 637 414 19.8 5.0 0.0467 0.0486
LMF 2A 0.75 1.00 in-line 1¼” 1¼” 318 481 702 414 18.8 7.0 0.0467 0.0620
LMF 3A 0.75 1.00 Horizontal 1¼” 1¼” 424 530 824 414 18.8 11.4 0.0467 0.0900
LMF 4A 1.10 1.50 in-line 1¼” 1¼” 318 481 775 478 24.4 7.0 0.0614 0.0620
LMF 5A 1.10 1.50 Horizontal 1¼” 1¼” 424 530 824 478 24.4 11.4 0.0614 0.0900
LMF 6A 1.10 1.50 Horizontal 1¼” 1¼” 424 726 1020 478 24.4 16.1 0.0614 0.1300
LMF 7A 1.50 2.00 Horizontal 1¼” 1¼” 424 530 824 503 26.4 11.4 0.0614 0.0900
LMF 8A 1.50 2.00 Horizontal 1¼” 1¼” 424 726 1020 503 26.4 16.1 0.0614 0.1300
Note: All dimensions in mm unless otherwise noted.
HYDRO PRESSURE BOOSTER PUMPS

DIMENSIONS & WEIGHT

DNd

b
DNs
DNd

c
c

DNs

b d

HORIZONTAL IN-LINE
SYSTEM MOTOR POWER TYPE OF DNs DNd DIMENSIONS [mm] GROSS WEIGHT [kg] GROSS VOLUME [m³]
TYPE kW HP TANK [BSP] [BSP] a b c d PUMP TANK PUMP TANK
MH2 1B 0.55 0.75 in-line 1" 1” 202 313 572 321 18.1 0.0879
MH2 1A 0.55 0.75 in-line 1" 1” 290 447 706 321 20.5 0.0879
MH2 2A 0.75 1.00 in-line 1" 1” 290 447 706 376 20.7 0.0879
MH2 3A 0.75 1.00 in-line 1" 1” 318 481 740 376 15.7 7.0 0.0430 0.0620
MH2 4A 0.75 1.00 Horizontal 1" 1” 424 530 789 376 15.7 11.4 0.0430 0.0900
MH2 7A 0.75 1.00 in-line 1" 1” 318 481 740 395 16.5 7.0 0.0430 0.0620
MH2 8A 0.75 1.00 Horizontal 1" 1” 424 530 789 395 16.5 11.4 0.0430 0.0900
MH4 1B 0.55 0.75 in-line 1¼" 1” 202 313 572 360 18.5 0.0879
MH4 1A 0.55 0.75 in-line 1¼" 1” 290 447 706 360 21.0 0.0879
MH4 2A 0.75 1.00 in-line 1¼" 1” 290 447 706 385 22.3 0.0879
MH4 3A 0.75 1.00 in-line 1¼" 1” 318 481 740 385 15.5 7.0 0.0430 0.0620
MH4 4A 0.75 1.00 Horizontal 1¼" 1” 424 530 789 385 15.2 11.4 0.0430 0.0900
MH4 5A 0.93 1.25 Horizontal 1¼" 1” 424 530 789 449 21.4 11.4 0.0550 0.0900
MH4 6A 0.93 1.25 Horizontal 1¼" 1” 424 726 985 449 21.4 16.1 0.0550 0.1300
MH4 7A 1.10 1.50 Horizontal 1¼" 1” 424 530 789 476 23.4 11.4 0.0550 0.0900
MH4 8A 1.10 1.50 Horizontal 1¼” 1” 424 726 985 476 23.4 16.1 0.0550 0.1300
Note: All dimensions in mm unless otherwise noted.
LUBI INDUSTRIES LLP
Near Kalyan Mills, Naroda Road, Ahmedabad-380 025, INDIA.
Phone : +91 - 79 - 61700100, Fax No. :+91 - 79 - 61700399.
Sales Enquiries: mktsales@lubipumps.com, expsales@lubipumps.com
www.lubipumps.com
Product Improvement is a continuous process at ‘LUBI’. The data given in this publication is therefore subject to revision.
01.00.071016.0050 Customer Care Number : 09824200800