Sirius 3RW55
Sirius 3RW55
■ Benefits
6
Automatic parameterization Extremely easy commissioning and reliability even under changing load
conditions
Hybrid switching devices and three-phase motor control Minimum power loss and optimum/symmetrical motor control
Integration into TIA Portal – communication modules optional Efficient configuration and maximum flexibility in automation engineering
Removable HMI with color display, local interface, slot for micro SD memory Maximum flexibility with regard to user interface and intuitive menu guidance
card
Pump stop and torque control Reduced mechanical loading and optimum pump stop control
Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors
■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25099/faq
https://support.industry.siemens.com/cs/ww/en/ps/25099/td Simulation Tool for Soft Starters (STS), see page 6/8 or
Equipment Manual "SIRIUS 3RW55 Soft Starter", see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753752
6
side-by-side mounting
• Above mm 100
• At the side mm 5
• Below mm 75
Maximum installation m 5 000 2 000 5 000 2 000 5 000 2 000
altitude above sea level1)
Degree of protection IP00
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and °C -40 ... +80
transport
Environmental category
according to IEC 60721
• During operation 3K6 (no ice formation, no condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not enter the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1) Derating from 1 000 m, see characteristic curve on page 6/8.
2)
Note derating above 40 °C.
6
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 26/23.6/21.2 29/26/23
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 2.5/13 3.5/18 5/25 6.5/32 7.5/38
• Minimum/maximum in inside-delta circuits A 4.3/22.5 6.1/31.1 8.7/43.3 11.3/55.4 13/65.8
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 43.4/38/34.4 53/48/43 68/62/56 82.5/75.5/65
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 5/25 10/47 13/63 16/77 19/93
• Minimum/maximum in inside-delta circuits A 8.7/43.3 17.3/81.4 22.5/109 27.7/133 32.9/161
Type 10
3RW5534 3RW5535 3RW5536
Rated operational current Ie A 113 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 113/101/89 143/128/118 171/153/141
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43
- Start-up time 10 s 1/h 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28
- Start-up time 10 s 1/h 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 21 21 21
- Start-up time 10 s 1/h 8 8 8
6
• 350% IM
- Start-up time 5 s 1/h 13 13 13
- Start-up time 10 s 1/h 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 128/113/103 141/129/117
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 89/81/74 108/98/88 117/105/93
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 23/113 29/143 34/171
• Minimum/maximum in inside-delta circuits A 39.8/195 50.2/247 58.9/296
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 10 2
- Start-up time 10 s 1/h 4 4 4 4 2 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 231/207/183 258/230/202 272/254/236 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 138/122/106 160/140/120 183/159/135 202/174/160 210/190/170 220/200/180
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 42/210 50/250 63/315 74/370 94/470 114/570
• Minimum/maximum in inside-delta circuits A 72.7/363 86.6/433 109.1/545 128.2/640 162.8/814 197.5/987
6
• 350% IM
- Start-up time 5 s 1/h 13 13 10 9 1
- Start-up time 10 s 1/h 4 4 2 2 1
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 500/450/400 520/470/420 570/520/470 920/840/760 980/900/810
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 380/340/300 400/360/320 420/380/340 740/670/600 790/720/650
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 114/630 144/720 168/840 220/1 100 258/1 280
• Minimum/maximum in inside-delta circuits A 197.5/987 249.4/1 247 291/1 454 381.1/1 905 446.9/2 217
Q1 Q1
Q11 Q11
NSB0_01902
IC01_00544
M M
3~ 3~
ToC
coordina- 1
tion "1"
3RW5513 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5514 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5515 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5516 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5517 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5521 -- -- -- -- -- -- -- --
3RW5524 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5525 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5526 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5527 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5534 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5535 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5536 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5543 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5544 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5545 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5546 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5547 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5548 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5552 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5553 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5554 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5556 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65 -- -- -- --
3RW5558 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65 -- -- -- --
Note:
The service factor or measurement inaccuracies have been
taken into account, for example, for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers than
those specified can be used at any time as smaller ones trip
more quickly in the event of a short circuit (unchanged short-
circuit breaking capacity) and thus protect the soft starter in any
case. The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor and
the line protection for the cables used.
In 690 V systems, in motor feeder tests with soft starters demon-
strable short-circuit breaking capacities can only be achieved
with the use of fuses (Iq > 5 to 10 kA).
F1 F1 F1
IC01_00545a
NSB0_01904
IC01_00565
M M M
3~ 3~ 3~
Soft starters gG class fuse Line contactor (optional) gG class fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems for systems
6
up to 690 V up to 480 V up to 690 V up to 600 V up to 480 V up to 600 V up to 480 V up to 600 V
in the supply in the supply in the delta in the delta
cable cable
Q11 F1 Q21 Q21 F1 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 1
tion "1"
3RW5513 3NA3820-6 3RT2025 3RT2025 3NA3820-6 3RT2027 3RT2035 3RT2025 3RT2025
3RW5514 3NA3820-6 3RT2026 3RT2027 3NA3820-6 3RT2027 3RT2037 3RT2026 3RT2027
3RW5515 3NA3822-6 3RT2027 3RT2037 3NA3822-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5516 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2037 3RT2038 3RT2035 3RT2037
3RW5517 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2038 3RT2046 3RT2035 3RT2037
3RW5521 3NA3824-6 3RT2027 3RT2037 3NA3824-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5524 3NA3824-6 3RT2036 3RT2037 3NA3824-6 3RT2046 3RT2047 3RT2036 3RT2037
3RW5525 3NA3830-6 3RT2037 3RT2046 3NA3830-6 3RT2047 3RT1054 3RT2037 3RT2046
3RW5526 3NA3132-6 3RT2038 3RT2046 3NA3132-6 3RT1055 3RT1055 3RT2038 3RT2046
3RW5527 3NA3136-6 3RT2046 3RT2047 3NA3136-6 3RT1056 3RT1056 3RT2046 3RT2047
3RW5534 3NA3244-6 3RT1054 3RT1054 3NA3244-6 3RT1064 3RT1064 3RT1054 3RT1054
3RW5535 3NA3244-6 3RT1055 3RT1055 3NA3244-6 3RT1065 3RT1065 3RT1055 3RT1055
3RW5536 3NA3365-6 3RT1056 3RT1064 3NA3365-6 3RT1066 3RT1075 3RT1056 3RT1064
3RW5543 2 x 3NA3354-6 3RT1064 3RT1064 2 x 3NA3354-6 3RT1075 3RT1075 3RT1064 3RT1064
3RW5544 2 x 3NA3354-6 3RT1065 3RT1065 2 x 3NA3354-6 3RT1076 3RT1076 3RT1065 3RT1065
3RW5545 2 x 3NA3365-6 3RT1075 3RT1075 2 x 3NA3365-6 3TF68 3TF68 3RT1075 3RT1075
3RW5546 2 x 3NA3365-6 3RT1075 3RT1075 2 x 3NA3365-6 3TF69 3TF69 3RT1075 3RT1075
3RW5547 2 x 3NA3365-6 3RT1076 3RT1276 2 x 3NA3365-6 3TF69 3TF69 3RT1076 3RT1276
3RW5548 2 x 3NA3365-6 3TF68 3TF68 2 x 3NA3365-6 -- -- 3TF68 3TF68
3RW5552 2 x 3NA3365-6 3TF68 3TF69 -- -- -- 3TF68 3TF69
3RW5553 2 x 3NA3365-6 3TF69 3TF69 -- -- -- 3TF69 3TF69
3RW5554 2 x 3NA3365-6 -- -- -- -- -- -- --
3RW5556 3 x 3NA3365-6 -- -- -- -- -- -- --
3RW5558 3 x 3NA3365-6 -- -- -- -- -- -- --
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
In inside-delta circuits, motor feeders with soft starters can only
be operated in systems with up to 600 V.
F’1
Q21
Q11
NSB0_01905
M
3~
F1 F1 F1
F3 F3 F3
IC01_00546a
IC01_00566
M M M
3~ 3~ 3~
Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)
6
for systems for systems for sys- for sys- for systems for systems for systems for systems for sys- for sys-
up to 690 V up to 690 V tems tems up to 600 V up to 600 V up to 480 V up to 600 V tems tems
up to up to in the sup- in the sup- up to up to
480 V 690 V ply cable ply cable 480 V 600 V
in the delta in the delta
Q11 F1 F3 Q21 Q21 F1 F3 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 2
tion "2"
3RW5513 3NA3820-6 3NE8017-1 3RT2025 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2035 3RT2025 3RT2025
3RW5514 3NA3820-6 3NE8020-1 3RT2026 3RT2027 3NA3820-6 3NE8020-1 3RT2027 3RT2037 3RT2026 3RT2027
3RW5515 3NA3822-6 3NE8021-1 3RT2027 3RT2037 3NA3822-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5516 3NA3824-6 3NE8022-1 3RT2035 3RT2037 3NA3824-6 3NE8022-1 3RT2037 3RT2038 3RT2035 3RT2037
3RW5517 3NA3824-6 3NE8024-1 3RT2035 3RT2037 3NA3824-6 3NE8024-1 3RT2038 3RT2046 3RT2035 3RT2037
3RW5521 3NA3824-6 3NE8021-1 3RT2027 3RT2037 3NA3824-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5524 3NA3824-6 3NE8024-1 3RT2036 3RT2037 3NA3824-6 3NE8024-1 3RT2046 3RT2047 3RT2036 3RT2037
3RW5525 3NA3830-6 3NE3227 3RT2037 3RT2046 3NA3830-6 3NE3227 3RT2047 3RT1054 3RT2037 3RT2046
3RW5526 3NA3132-6 3NE3227 3RT2038 3RT2046 3NA3132-6 3NE3227 3RT1055 3RT1055 3RT2038 3RT2046
3RW5527 3NA3136-6 3NE3227 3RT2046 3RT2047 3NA3136-6 3NE3227 3RT1056 3RT1056 3RT2046 3RT2047
3RW5534 3NA3244-6 3NE3231 3RT1054 3RT1054 3NA3244-6 3NE3231 3RT1064 3RT1064 3RT1054 3RT1054
3RW5535 3NA3244-6 3NE3233 3RT1055 3RT1055 3NA3244-6 3NE3233 3RT1065 3RT1065 3RT1055 3RT1055
3RW5536 3NA3365-6 3NE3334-0B 3RT1056 3RT1064 3NA3365-6 3NE3334-0B 3RT1066 3RT1075 3RT1056 3RT1064
3RW5543 2 x 3NA3354-6 3NE3333 3RT1064 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1075 3RT1064 3RT1064
3RW5544 2 x 3NA3354-6 3NE3335 3RT1065 3RT1065 2 x 3NA3354-6 3NE3335 3RT1076 3RT1076 3RT1065 3RT1065
3RW5545 2 x 3NA3365-6 -- 3RT1075 3RT1075 2 x 3NA3365-6 -- 3TF68 3TF68 3RT1075 3RT1075
3RW5546 2 x 3NA3365-6 -- 3RT1075 3RT1075 2 x 3NA3365-6 -- 3TF69 3TF69 3RT1075 3RT1075
3RW5547 2 x 3NA3365-6 3NE3340-8 3RT1076 3RT1276 2 x 3NA3365-6 3NE3340-8 3TF69 3TF69 3RT1076 3RT1276
3RW5548 2 x 3NA3365-6 3NC3342-1U 3TF68 3TF68 2 x 3NA3365-6 3NC3342-1U -- -- 3TF68 3TF68
3RW5552 2 x 3NA3365-6 3NC3343-1U 3TF68 3TF69 -- 3NC3343-1U -- -- 3TF68 3TF69
3RW5553 2 x 3NA3365-6 3NC3343-1U 3TF69 3TF69 -- 3NC3343-1U -- -- 3TF69 3TF69
3RW5554 2 x 3NA3365-6 3NC3343-1U -- -- -- 3NC3343-1U -- -- -- --
3RW5556 3 x 3NA3365-6 3 x 3NE3340-8 -- -- -- 3 x 3NE3340-8 -- -- -- --
3RW5558 3 x 3NA3365-6 3 x 3NE3340-8 -- -- -- 3 x 3NE3340-8 -- -- -- --
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class
full-range fuses for cable and line protection 3NA3 (F1),
3RV2/3VA motor starter protectors/circuit breakers can also be
used, possibly with reduced short-circuit breaking capacity
(see page 6/22). In these cases, optional line contactors can be
dispensed with.
In inside-delta circuits, motor feeders with soft starters can only
be operated in systems with up to 600 V.
3RW551. 3RW552.
6
Operational voltage 200 ... 480 V
13 3 5.5 -- -- 11.5 2 3 7.5 -- 5 3RW5513-@HA@4 1 1 unit 42S
18 4 7.5 -- -- 15.9 3 5 10 -- 5 3RW5514-@HA@4 1 1 unit 42S
25 5.5 11 -- -- 22.3 5 7.5 15 -- 5 3RW5515-@HA@4 1 1 unit 42S
32 7.5 15 -- -- 28.4 7.5 10 20 -- 5 3RW5516-@HA@4 1 1 unit 42S
38 11 18.5 -- -- 33.5 10 10 20 -- 5 3RW5517-@HA@4 1 1 unit 42S
47 11 22 -- -- 41.6 10 10 30 -- 5 3RW5524-@HA@4 1 1 unit 42S
63 18.5 30 -- -- 55.5 15 20 40 -- 5 3RW5525-@HA@4 1 1 unit 42S
77 22 37 -- -- 68 20 25 50 -- 5 3RW5526-@HA@4 1 1 unit 42S
93 22 45 -- -- 82.5 25 30 60 -- 5 3RW5527-@HA@4 1 1 unit 42S
3RW551. 3RW552.
6
25 5.5 11 15 -- 22.3 5 7.5 15 20 5 3RW5515-@HA@5 1 1 unit 42S
32 7.5 15 18.5 -- 28.4 7.5 10 20 25 5 3RW5516-@HA@5 1 1 unit 42S
38 11 18.5 22 -- 33.5 10 10 20 30 5 3RW5517-@HA@5 1 1 unit 42S
Operational voltage 200 ... 690 V
25 5.5 11 15 22 22.3 5 7.5 15 20 5 3RW5521-@HA@6 1 1 unit 42S
47 11 22 30 45 41.6 10 10 30 40 5 3RW5524-@HA@6 1 1 unit 42S
63 18.5 30 37 55 55.5 15 20 40 50 5 3RW5525-@HA@6 1 1 unit 42S
77 22 37 45 75 68 20 25 50 60 5 3RW5526-@HA@6 1 1 unit 42S
93 22 45 55 90 82.5 25 30 60 75 5 3RW5527-@HA@6 1 1 unit 42S
3RW551. 3RW552.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
6
Operational voltage 200 ... 480 V
22.5 5.5 11 -- 19.9 5 5 10 -- 5 3RW5513-@HA@4 1 1 unit 42S
31.5 7.5 15 -- 28 7.5 7.5 20 -- 5 3RW5514-@HA@4 1 1 unit 42S
43.3 11 18.5 -- 39 10 10 25 -- 5 3RW5515-@HA@4 1 1 unit 42S
55.4 15 22 -- 49 15 15 30 -- 5 3RW5516-@HA@4 1 1 unit 42S
65.8 18.5 30 -- 58 15 20 40 -- 5 3RW5517-@HA@4 1 1 unit 42S
81.4 22 45 -- 72 20 25 50 -- 5 3RW5524-@HA@4 1 1 unit 42S
109 30 55 -- 96 30 30 75 -- 5 3RW5525-@HA@4 1 1 unit 42S
133 37 75 -- 118 30 40 75 -- 5 3RW5526-@HA@4 1 1 unit 42S
161 45 90 -- 143 40 50 100 -- 5 3RW5527-@HA@4 1 1 unit 42S
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 480 V
6
3RW551. 3RW552.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
22.5 5.5 11 15 19.9 5 5 10 15 5 3RW5513-@HA@5 1 1 unit 42S
31.5 7.5 15 18.5 28 7.5 7.5 20 25 5 3RW5514-@HA@5 1 1 unit 42S
6
43.3 11 18.5 22 39 10 10 25 30 5 3RW5515-@HA@5 1 1 unit 42S
55.4 15 22 30 49 15 15 30 40 5 3RW5516-@HA@5 1 1 unit 42S
65.8 18.5 30 37 58 15 20 40 50 5 3RW5517-@HA@5 1 1 unit 42S
43.3 11 18.5 22 39 10 10 25 30 5 3RW5521-@HA@6 1 1 unit 42S
81.4 22 45 45 72 20 25 50 60 5 3RW5524-@HA@6 1 1 unit 42S
109 30 55 55 96 30 30 75 75 5 3RW5525-@HA@6 1 1 unit 42S
133 37 75 90 118 30 40 75 100 5 3RW5526-@HA@6 1 1 unit 42S
161 45 90 110 143 40 50 100 125 5 3RW5527-@HA@6 1 1 unit 42S
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
6
3RW5983-0TC20
3RW554 (2x) -- -- } 3RW5984-0TC20 1 1 unit 42S
6
3RW5984-0TC20
Enclosure components
Hinged cover 3RW55 Without -- } 3RW5950-0GL20 1 1 unit 42S
cutout
3RW5950-0GL20
Communication modules
Communica- 3RW55 PROFINET -- } 3RW5950-0CH00 1 1 unit 42S
tion module High Feature
with integral
switch
PROFINET -- } 3RW5980-0CS00 1 1 unit 42S
Standard
PROFIBUS -- } 3RW5980-0CP00 1 1 unit 42S
3RW5980-0CS00
EtherNet/IP -- } 3RW5980-0CE00 1 1 unit 42S
3RW5980-0CE00
Modbus RTU -- } 3RW5980-0CR00 1 1 unit 42S
Modbus TCP -- } 3RW5980-0CT00 1 1 unit 42S
3RW5980-0CR00
3RW5980-0HD00
Connecting cables
HMI connec- 3RW55 5 m, round For door } 3RW5980-0HC60 1 1 unit 42S
tion cable 2.5 m, round mounting } 3UF7933-0BA00-0 1 1 unit 42J
1.0 m, round } 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round } 3UF7932-0BA00-0 1 1 unit 42J
6
3UF793.-0BA00-0
Further accessories
Push-in lugs -- Two lugs are For HMI 2 3ZY1311-0AA00 1 10 units 41L
for wall required per modules and
mounting device communica-
tion modules
3ZY1311-0AA00
Blank labels
Unit labeling 20 mm x For SIRIUS 20 3RT2900-1SB20 100 340 units 41B
plates1) 7 mm, devices
titanium gray
IC01_00181
3RT2900-1SB20
3RW55 starter kit
SIRIUS -- Including 5 3RW5951-1ES04 1 1 unit 42S
3RW55 3RW55 soft starter 13 A,
starter kit 200 ... 480 V, 24 V AC/DC
Soft Starter ES V15.1,
24 V power supply unit,
connecting cable and
RJ45 network cable
3RW5951-1ES04
1)
PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/15).
■ Overview
More information
Homepage, see www.siemens.com/soft-starter Simulation Tool for Soft Starters (STS), see page 6/8 or
Industry Mall, see www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/101494917
Industry Online Support (SIOS) topic page, see SIRIUS Soft Starter ES (TIA Portal), see page 14/2
https://support.industry.siemens.com/cs/ww/en/view/109747404
6
5
1
6
7
IC01_00690
2 4
3RW55 Failsafe High Performance soft starters with accessories (see page 6/52)
■ Benefits
6
Automatic parameterization Extremely easy commissioning and reliability even under changing load
conditions
Hybrid switching devices and three-phase motor control Minimum power loss and optimum/symmetrical motor control
Integration into TIA Portal – communication modules optional Efficient configuration and maximum flexibility in automation engineering
Removable HMI with color display, local interface, slot for micro SD memory Maximum flexibility with regard to user interface and intuitive menu guidance
card
Pump stop and torque control Reduced mechanical loading and optimum pump stop control
Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors
Fail-safe disconnection up to SIL 3 - PL e / STO Reduced costs and space requirements thanks to direct wiring of the
EMERGENCY STOP mushroom pushbutton to the soft starter for SIL 1
■ Technical specifications
More information
Technical specifications, see FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25776/faq
https://support.industry.siemens.com/cs/ww/en/ps/25776/td Simulation Tool for Soft Starters (STS), see page 6/8 or
Equipment Manual "SIRIUS 3RW55 Soft Starter", see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753752
D
W
6
• Below mm 75
Maximum installation altitude above sea level1) m 2 000
Degree of protection IP00
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and transport °C -40 ... +80
Environmental category according to IEC 60721
• During operation 3K6 (no ice formation, no condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not enter the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1)
Derating from 1 000 m, see characteristic curve on page 6/8.
2)
Note derating above 40 °C.
Type 3RW55..-.HF.4
Power electronics
Operational voltage, rated value V 200 ... 480
• Relative negative tolerance/relative positive tolerance % -15/10
Operational voltage for inside-delta circuit, rated value V 200 ... 480
• Relative negative tolerance/relative positive tolerance % -15/10
6
6
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 26/23.6/21.2 29/26/23
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 2.5/13 3.5/18 5/25 6.5/32 7.5/38
• Minimum/maximum in inside-delta circuits A 4.3/22.5 6.1/31.1 8.7/43.3 11.3/55.4 13/65.8
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7
- Start-up time 40 s 1/h 2.5 0 0 0
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 43.4/38/34.4 53/48/43 68/62/56 82.5/75.5/65
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 10/47 13/63 16/77 19/93
• Minimum/maximum in inside-delta circuits A 17.3/81.4 22.5/109 27.7/133 32.9/161
6
• 350% IM
- Start-up time 5 s 1/h 13 4 0
- Start-up time 10 s 1/h 4 0 0
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 128/113/103 141/129/117
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 6 6
- Start-up time 40 s 1/h 0 0 0
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 89/81/74 108/98/88 117/105/93
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 23/113 29/143 34/171
• Minimum/maximum in inside-delta circuits A 39.8/195 50.2/247 58.9/296
• 350% IM
- Start-up time 5 s 1/h 0 13 5 12 6 1
- Start-up time 10 s 1/h 0 4 0 3 0.4 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 231/207/183 258/230/202 272/254/236 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 138/122/106 160/140/120 183/159/135 202/174/160 210/190/170 220/200/180
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3 3
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 42/210 50/250 63/315 74/370 94/470 114/570
• Minimum/maximum in inside-delta circuits A 72.7/363 86.6/433 109.1/545 128.2/640 162.8/814 197.5/987
Q1 Q1
Q11 Q11
NSB0_01902
IC01_00544
M M
3~ 3~
6
ToC
coordina- 1
tion "1"
3RW5513 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5514 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5515 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5516 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5517 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5524 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5525 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5526 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5527 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5534 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5535 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5536 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5543 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5544 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5545 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5546 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5547 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5548 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
Note:
The service factor or measurement inaccuracies have been
taken into account, for example, for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers than
those specified can be used at any time as smaller ones trip
more quickly in the event of a short circuit (unchanged short-
circuit breaking capacity) and thus protect the soft starter in any
case. The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor and
the line protection for the cables used.
F1 F1 F1
IC01_00545a
NSB0_01904
IC01_00565
M M M
3~ 3~ 3~
Soft starters gG class fuse Line contactor gG class fuse Line contactor (optional)
(optional)
6
for systems for systems for systems for systems for systems
up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V
in the supply cable in the delta
Q11 F1 Q21 F1 Q21 Q21
Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 1
tion "1"
3RW5513 3NA3820-6 3RT2025 3NA3820-6 3RT2027 3RT2025
3RW5514 3NA3820-6 3RT2026 3NA3820-6 3RT2027 3RT2026
3RW5515 3NA3822-6 3RT2027 3NA3822-6 3RT2036 3RT2027
3RW5516 3NA3824-6 3RT2035 3NA3824-6 3RT2037 3RT2035
3RW5517 3NA3824-6 3RT2035 3NA3824-6 3RT2038 3RT2035
3RW5524 3NA3824-6 3RT2036 3NA3824-6 3RT2046 3RT2036
3RW5525 3NA3830-6 3RT2037 3NA3830-6 3RT2047 3RT2037
3RW5526 3NA3132-6 3RT2038 3NA3132-6 3RT1055 3RT2038
3RW5527 3NA3136-6 3RT2046 3NA3136-6 3RT1056 3RT2046
3RW5534 3NA3244-6 3RT1054 3NA3244-6 3RT1064 3RT1054
3RW5535 3NA3244-6 3RT1055 3NA3244-6 3RT1065 3RT1055
3RW5536 3NA3365-6 3RT1056 3NA3365-6 3RT1066 3RT1056
3RW5543 2 x 3NA3354-6 3RT1064 2 x 3NA3354-6 3RT1075 3RT1064
3RW5544 2 x 3NA3354-6 3RT1065 2 x 3NA3354-6 3RT1076 3RT1065
3RW5545 2 x 3NA3365-6 3RT1075 2 x 3NA3365-6 3TF68 3RT1075
3RW5546 2 x 3NA3365-6 3RT1075 2 x 3NA3365-6 3TF69 3RT1075
3RW5547 2 x 3NA3365-6 3RT1076 2 x 3NA3365-6 3TF69 3RT1076
3RW5548 2 x 3NA3365-6 3TF68 2 x 3NA3365-6 -- 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F’1
Q21
Q11
NSB0_01905
M
3~
6
up to 480 V up to 480 V
Q11 F’1 Q21
Type Type Type
Type of ToC Inline circuit
coordina- 2
tion "2"
3RW5513 3NE1815-0 3RT2025
3RW5514 3NE1802-0 3RT2026
3RW5515 3NE1817-0 3RT2027
3RW5516 3NE1818-0 3RT2035
3RW5517 3NE1820-0 3RT2035
3RW5524 3NE1021-2 3RT2036
3RW5525 3NE1022-0 3RT2037
3RW5526 3NE1224-0 3RT2038
3RW5527 3NE1224-0 3RT2046
3RW5534 3NE1225-0 3RT1054
3RW5535 3NE1227-0 3RT1055
3RW5536 3NE1230-0 3RT1056
3RW5543 3NE1230-2 3RT1064
3RW5544 3NE1331-0 3RT1065
3RW5545 3NE1334-2 3RT1075
3RW5546 3NE1334-2 3RT1075
3RW5547 3NE1436-2 3RT1076
3RW5548 3NE1437-2 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
In inside-delta circuits, a gR class full-range fuse could not
provide the semiconductor protection of the delta-connected
soft starter with a short-circuit breaking capacity that is
adequate for practical use. In this case, we recommend using
aR class partial-range fuses for semiconductor protection for
type of coordination "2" (see page 6/48).
F1 F1 F1
F3 F3 F3
IC01_00546a
IC01_00566
M M M
3~ 3~ 3~
Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)
6
for systems for systems for systems for systems for systems for systems for systems
up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V
in the supply in the delta
cable
Q11 F1 F3 Q21 F1 F3 Q21 Q21
Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 2
tion "2"
3RW5513 3NA3820-6 3NE8017-1 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2025
3RW5514 3NA3820-6 3NE8020-1 3RT2026 3NA3820-6 3NE8020-1 3RT2027 3RT2026
3RW5515 3NA3822-6 3NE8021-1 3RT2027 3NA3822-6 3NE8021-1 3RT2036 3RT2027
3RW5516 3NA3824-6 3NE8022-1 3RT2035 3NA3824-6 3NE8022-1 3RT2037 3RT2035
3RW5517 3NA3824-6 3NE8024-1 3RT2035 3NA3824-6 3NE8024-1 3RT2038 3RT2035
3RW5524 3NA3824-6 3NE8024-1 3RT2036 3NA3824-6 3NE8024-1 3RT2046 3RT2036
3RW5525 3NA3830-6 3NE3227 3RT2037 3NA3830-6 3NE3227 3RT2047 3RT2037
3RW5526 3NA3132-6 3NE3227 3RT2038 3NA3132-6 3NE3227 3RT1055 3RT2038
3RW5527 3NA3136-6 3NE3227 3RT2046 3NA3136-6 3NE3227 3RT1056 3RT2046
3RW5534 3NA3244-6 3NE3231 3RT1054 3NA3244-6 3NE3231 3RT1064 3RT1054
3RW5535 3NA3244-6 3NE3233 3RT1055 3NA3244-6 3NE3233 3RT1065 3RT1055
3RW5536 3NA3365-6 3NE3334-0B 3RT1056 3NA3365-6 3NE3334-0B 3RT1066 3RT1056
3RW5543 2 x 3NA3354-6 3NE3333 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1064
3RW5544 2 x 3NA3354-6 3NE3335 3RT1065 2 x 3NA3354-6 3NE3335 3RT1076 3RT1065
3RW5545 2 x 3NA3365-6 -- 3RT1075 2 x 3NA3365-6 -- 3TF68 3RT1075
3RW5546 2 x 3NA3365-6 -- 3RT1075 2 x 3NA3365-6 -- 3TF69 3RT1075
3RW5547 2 x 3NA3365-6 3NE3340-8 3RT1076 2 x 3NA3365-6 3NE3340-8 3TF69 3RT1076
3RW5548 2 x 3NA3365-6 3NC3342-1U 3TF68 2 x 3NA3365-6 3NC3342-1U -- 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For CLASS 10 applications, as an alternative to the gG class
full-range fuses for cable and line protection 3NA3 (F1),
3RV2/3VA motor starter protectors/circuit breakers can also be
used, possibly with reduced short-circuit breaking capacity
(see page 6/45). In these cases, optional line contactors can be
dispensed with.
6
3RW5543 -- 3RT1064
3RW5544 -- 3RT1065
3RW5545 -- 3RT1075
3RW5546 -- 3RT1075
3RW5547 -- 3RT1076
3RW5548 -- 3TF68
6
22.5 5.5 11 19.9 5 5 10 5 3RW5513-@HF@4 1 1 unit 42S
31.5 7.5 15 28 7.5 7.5 20 5 3RW5514-@HF@4 1 1 unit 42S
43.3 11 18.5 39 10 10 25 5 3RW5515-@HF@4 1 1 unit 42S
55.4 15 22 49 15 15 30 5 3RW5516-@HF@4 1 1 unit 42S
65.8 18.5 30 58 15 20 40 5 3RW5517-@HF@4 1 1 unit 42S
81.4 22 45 72 20 25 50 5 3RW5524-@HF@4 1 1 unit 42S
109 30 55 96 30 30 75 5 3RW5525-@HF@4 1 1 unit 42S
133 37 75 118 30 40 75 5 3RW5526-@HF@4 1 1 unit 42S
161 45 90 143 40 50 100 5 3RW5527-@HF@4 1 1 unit 42S
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS* PG
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At current At At At
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp d
Operational voltage 200 ... 480 V
196 55 110 175 50 60 125 5 3RW5534-@HF@4 1 1 unit 42S
248 75 132 222 75 75 150 5 3RW5535-@HF@4 1 1 unit 42S
296 90 160 265 75 100 200 5 3RW5536-@HF@4 1 1 unit 42S
364 110 200 322 100 125 250 5 3RW5543-@HF@4 1 1 unit 42S
433 132 250 381 125 150 300 5 3RW5544-@HF@4 1 1 unit 42S
546 160 315 483 150 200 400 5 3RW5545-@HF@4 1 1 unit 42S
641 200 355 568 200 200 450 5 3RW5546-@HF@4 1 1 unit 42S
814 250 400 721 250 250 600 5 3RW5547-@HF@4 1 1 unit 42S
987 315 560 873 300 350 750 5 3RW5548-@HF@4 1 1 unit 42S
3RW5983-0TC20
3RW554 (2x) -- -- } 3RW5984-0TC20 1 1 unit 42S
6
3RW5984-0TC20
Enclosure components
Hinged cover 3RW55 Without -- } 3RW5950-0GL20 1 1 unit 42S
cutout
3RW5950-0GL20
Communication modules
Communica- 3RW55 PROFINET -- } 3RW5950-0CH00 1 1 unit 42S
tion module High Feature
with integral
switch
PROFINET -- } 3RW5980-0CS00 1 1 unit 42S
Standard
PROFIBUS -- } 3RW5980-0CP00 1 1 unit 42S
3RW5980-0CS00
EtherNet/IP -- } 3RW5980-0CE00 1 1 unit 42S
3RW5980-0CE00
Modbus RTU -- } 3RW5980-0CR00 1 1 unit 42S
Modbus TCP -- } 3RW5980-0CT00 1 1 unit 42S
3RW5980-0CR00
3RW5980-0HD00
Connecting cables
HMI connec- 3RW55 5 m, round For door } 3RW5980-0HC60 1 1 unit 42S
tion cable 2.5 m, round mounting } 3UF7933-0BA00-0 1 1 unit 42J
1.0 m, round } 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round } 3UF7932-0BA00-0 1 1 unit 42J
6
3UF793.-0BA00-0
Further accessories
Push-in lugs -- Two lugs are For HMI 2 3ZY1311-0AA00 1 10 units 41L
for wall required per modules and
mounting device communica-
tion modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For SIRIUS 20 3RT2900-1SB20 100 340 units 41B
plates1) 7 mm, devices
titanium gray
IC01_00181
3RT2900-1SB20
1)
PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/15).