Intelidrive Dcu Industrial
Intelidrive Dcu Industrial
Industrial
     SW version 3.4.0
        1 Document information                                        6
        2 System overview                                             9
        3 Application overview                                       27
        4 Installation and wiring                                    30
        5 Controller setup                                           63
        6 Communication                                              89
        7 Technical data                                             93
        8 Appendix                                                   97
2 System overview                                                         9
  2.1 Operator Interface                                                  9
      2.1.1 Controller screens                                            10
      2.1.2 Display menu                                                  16
      2.1.3 Functions available from ID-DCU Industrial front panel keys   17
      2.1.4 How to change controller language?                            18
      2.1.5 How to change the display backlight intensity?                18
      2.1.6 How to change the display contrast?                           18
      2.1.7 How to check the serial number and software revision?         18
      2.1.8 How to find active alarms?                                    18
      2.1.9 How to select engine mode?                                    18
      2.1.10 How to view and edit setpoints?                              19
      2.1.11 How to view measured data?                                   19
      2.1.12 How to view the History menu?                                19
      2.1.13 Main screen indication                                       19
  2.2 Controller configuration and monitoring                             20
      2.2.1 AirGate connection to the PC                                  20
      2.2.2 Configuration steps                                           21
      2.2.3 Direct conection to the PC                                    21
      2.2.4 DriveConfig                                                   22
      2.2.5 Modbus protocol                                               23
      2.2.6 Password protection                                           24
      2.2.7 WebSupervisor                                                 24
  2.3 List of supported modules                                           25
3 Application overview                                                    27
  3.1 ID-DCU Industrial                                                   27
      3.1.1 Default archives                                              27
      3.1.2 Operational modes                                             27
      3.1.3 Universal states                                              28
5 Controller setup                                                    63
  5.1 Function description details                                    63
      5.1.1 Engine running state                                      63
      5.1.2 Engine states                                             63
      5.1.3 Protections                                               64
      5.1.4 Universal states                                          71
  5.2 PLC - programmable functions                                    72
6 Communication                                        89
  6.1 InteliDrive – Engine ECU communication           89
      6.1.1 Example of standard J1939 engine           89
      6.1.2 Tier 4 Final/StageV                        89
7 Technical data                                       93
  7.1 ID-DCU Industrial                                93
  7.2 CAN bus interface                                95
8 Appendix                                             97
                Controller objects                     98
  8.1 List of controller objects types                 98
      8.1.1 Setpoints                                  98
      8.1.2 Binary Inputs                              159
      8.1.3 Binary outputs                             187
      8.1.4 Logical Analog Inputs                      233
      8.1.5 Values                                     253
  8.2 Extensional modules                              282
      8.2.1 Inteli AIN8 (I-AIN8)                       282
      8.2.2 Inteli AIN8TC                              292
      8.2.3 Inteli IO8/8 (I-IO8/8)                     297
      8.2.4 IS-BIN16/8                                 305
      8.2.5 Inteli AIO9/1 (I-AIO9/1)                   312
      8.2.6 IS-AIN8                                    317
      8.2.7 IS-AIN8TC                                  327
      8.2.8 IGS-PTM                                    331
      8.2.9 InternetBridge-NT                          338
      8.2.10 I-CB Communication bridge                 339
      8.2.11 I-AOUT8                                   340
      8.2.12 ID-COM                                    345
       IMPORTANT: This type of paragraph highlights a procedure, adjustment etc., which can cause a
       damage or improper function of the equipment if not performed correctly and may not be clear at
       first sight.
       Example: This type of paragraph contains information that is used to illustrate how a specific function
       works.
     IMPORTANT: Compatibility across HW version is incompatible, you can transfer just PLC sheets.
     FW upgrade functionality could not work on 100 % and ComAp does not recommend it.
Select the set point, select the screen or increase set point value.
Select the set point, select the screen or decrease set point value.
   Note:
   Stop button hold time is 0.5 sec. to avoid unwanted engine stop.
   The 2nd (0.5 sec) push of the Stop button cancels the ‘cooling state’ of the engine and stops the engine
   immediately. To avoid the cancel of the ‘cooling state’ by the 2nd push of the Stop button, use LBI card of the
   DriveConfig tool and make the association of Access Lock to the Cooling logical binary output of the ‘Source’
   column. It causes locking of the front panel buttons during the Cooling state.
    Screen                                        Content
    Hidden, but available by Key combination, see Functions available from ID-DCU Industrial front panel
    keys (page 17)
                                                  Info screen: Fw and App. version, s.n., .. Language list and switch.
                                                  Language screen
                                                  Fast edit screen
    Available using ↑ or ↓ front panel keys
                                                  ECU diagnostics code list
                                                  Alarm list
                                                  ID Mode, RPM1, Engine state, Oil Pressure and Coolant
                                                  temperature (alternatively Aftertreatment values)
    1 = Main screen
                                                  Indication: LOC (Local), Alarm (in AL or ECU list), R Remote data
                                                  connection active, L Access Lock
    2                                             Analog 1 to Analog 4 , 4x single barograph
    3                                             Analog 5 to Analog 8 , 4x single barograph (if they are configured)
                                                  Battery ID-DCU Industrial, bargraph, Engine Cylinders statistic
    4
                                                  temperatures, Engine states timer
    5                                             ID-DCU Industrial BI 1 to 7
    6                                             ID-DCU Industrial BI 8 to 14
    7                                             ID-DCU Industrial BO 1 to 7
    8                                             ID-DCU Industrial BO 8 to 14
    9                                             Statistics: Run hours, Number of starts, Service time
    10                                            GPS speed (value is shared from other devices)
    Following screens appears depend on configuration
                                                  Analog 1 to Analog 8, Name- value dimension, active alarm is
    Opt
                                                  negative (1x IS-AIN8(TC) or Inteli AIN8(TC))
    Opt                                           IS-BIN BI indication 1 to 8
    Opt                                           IS-BIN BI indication 9 to 16
    Opt                                           IS-BIN BO indication 1 to 8
    Opt                                           ECU values I.
    Opt                                           ECU values II.
   Alarm indication
   Possible Alarm list and History record prefixes
             E     n      g     O      i     l      P   r    e     s   s                     W    R   N
             B     o      o     s      t     P      r   e    s     s                         F    L   S
             E     n      g     O      i     l      T   e    m     p                         W    R   N
             6     2      9                                                                  F    L   S
      >      E     n      g     C      o     o      l   T    e     m   p                     F    L   S
S P 1 1 0 O C 7 F M 3 E 1 0
SP            SPN number (Suspect Parameter Number) is a particular code for each fault
OC            OC number (Occurrence Count) is ECU internal counter for each combination of SPN and FMI
FM            FMI number (Failure Mode Identifier) is a particular code for each cause of fault
E             Module index of ECU module, which transmits a fault
Info screen
      Info                                                   Comment
      InteliDrive                                            Product type
      ComAp 2019                                             Company name, year of release
      ID                                                     Controller type
      Serial: 0200FFFF                                       Controller serial number
      Sw ver: 3.4.0                                          Software version
      Appl:  SS                                              Application
      Branch: DCU Industrial                                 Firmware branch
                                   It is calculated:
  1    Run Hours                   Each finished 60 minutes when engine is running.
                                   Each successful start (starter is switched off due to RPM> Starting RPM) is
  2    NumSuccStarts               calculated.
                                   Each external (manual) engine start.
                                   Each finished unsuccessful cranking - MaxCrank time is over and engine is not
  3    NumUnscStarts
                                   started.
  4    Service Time                It is decreased each finished 60 minutes when engine is running.
  5    DayCons                     Daily fuel consumption, every liter of fuel is calculated.
  6    TripCons                    Trip fuel consumption, every liter of fuel is calculated.
  7    Memo1                       Each time rising edge is detected with LBI: Memo1 Trigger
  8    Memo2                       Each time rising edge is detected with LBI: Memo2 Trigger
                                   Momentary average fuel consumption per nautical mile. Calculated from fuel
                                   consumption and boat speed.
  9    MomAvgFlCon L
                                   Result is not rounded, e.g. 9/100 is displayed as 0,0
                                   If FuelConsumpt is 0 then MomAvgFlCon L is displayed as invalid value #####.
Note: Statistic values can be adjusted from InteliMonitor, password 3 level protected by default.
 Note: Internal display does not support Unsigned Long values so it does not display correctly values higher
 than 2,147,483,647. Could be roughly says that issue is connected with values having 10 digits and more.If
 there is higher value, it treats it as Signed long and show it as negative with "-" (minus sign).Workaround: If
 numbers with 10 digits has unlogically minus mark number should be recalculated.
 History records
 Following table does not contain Wrn, Sd and Fls messages from external units.
  Note: Value name can’t exceed 11 characters to be recorded to History file with prefix (Wrn, Fls etc.). Longer
  names characters are canceled.
  Corresponding Sd BINx, Sd BOUTx or Sd AINx is indicated in Alarm list and history record when
  communication with any extension units (IS-BIN, IS-AIN, IGS-PTM) is interrupted.
      Example: When IS-BIN16/8 is configured for addresses: Binary inputs = BIN1, BIN2 and Binary outputs =
      BOUT1, then three messages Sd BIN1, Sd BIN2, Sd BOUT1 are indicated after communication is
      interrupted.
Note: Any “State” information can be configured to any binary output by DriveConfig software.
  Note: If the configuration table has a code page that is not supported in the display processor, “Unsupported
  code page” message appears on the ID-DCU Industrial screen. Press Page to return back to Language
  selection.
  Note: The Fast Edit function is available only in case of accessible parameter, i.e. if entered password level on
  ID-DCU Industrial corresponds to protected level of parameter associated to Fast Edit function.
Available mode
RPM indication
  Note: AirGate ID needed as parameter for connection creation is assigned to InteliBridge-NT (IB-NT) module.
  Second parameter for connection to a particular controller is controller’s address (there can be connected up to
  8 ID-DCU Industrial controllers via CAN2 bus to one IB-NT module).
  Translator
  The Translator enables to translate all or some texts to up 5 languages that could be available in controller.
  Controller language can be changed from panel buttons. It is possible to operate different languages on each ID-
  DCU Industrial, Remote panel and InteliMonitor.
  Note: Check all screens if some texts are not shortened.
  Delivered controller contains firmware and default configuration. Any Application file can be modified by
  customer using DriveConfig PC software. It is possible to download Application file from the controller, modify it
  and download back. There must be corresponding version of Application file with firmware in controller.
  Note: Configuration aid file does not contain the History record when had been read from the InteliDrive
  controller by DriveConfig.
Note: To load History file from InteliDrive use InteliMonitor software only.
2.2.7 WebSupervisor
  WebSupervisor is web based system designed for monitoring and controlling ComAp controllers via the
  Internet. This system offers a number of beneficial features that help optimize revenue for machinery fleets, as
  each piece of equipment can be individually monitored for all important operation values.
  Note: The WebSupervisor ComAp tool is supported from ID-DCU Industrial version 3.1, specifically from ID-
  DCU-INDUSTRIAL-W-3.1.mhx firmware.
 You can get more information on wiring of standard extension modules in the chapter Extensional modules
 (page 282).
 6 back to System overview
   OFF mode
   All ID-DCU Industrial controller is switched off. Engine can’t be started or running engine is stopped,
   prelubrication function is not active. Firmware and controller configuration can be changed in OFF mode only.
  RUN mode
      Controller starts and stops the engine according to the binary inputs Blackout Start or Remote Start, Rem
      Start/Stop, Remote Stop or to the ID-DCU IndustrialStart / Stop buttons. Binary inputs Blackout Start and
      Remote Start and Remote Stop are inactive in LOC (Local) mode.
      All engine protections and all configured shutdown protections are active. Controller continuously monitors
      all available engine parameters (oil pressure, water temperature, RPM, fuel level etc.). The engine will stop
      and activates Common Warning and Common Shutdown outputs and writes record to the history file
      when detects any active Shut down alarm. This condition can be signaled by Active call feature to remote
      operator via modem, SMS or e-mail.
  Other functions
  Controller (except OFF mode) accepts when engine is started outside controller (by hand) or when controller
  power supply is switched-on on already running engine.
  There are seven universal (free) states available in ID-DCU Industrial-3.4.0 that are not joined to any value or
  input.
  They can be used mostly for some values that have not state (e.g. RPM or other that are not measured on
  Analog input). This way can be configured protection to any ID-DCU Industrial internal value or more levels
  external indication.
  Example of Universal state1 configuration to Engine speed (Warning for Engine speed > 1600RPM, 1s):
  This configuration is available in DriveConfig – Expert mode.
4.1.3 ECU
  Electronic Control Unit is kind of extension module connected to CAN1 bus or serial line and communicating via
  electronic signal (J1939 or Modbus protocol). Generally can read binary and analog values from engine (inputs)
  and transmit binary outputs (e.g. Start, Stop commands) and analog outputs (e.g. Speed request). ECU size
  (count of input and output resources) are configurable and depends on controller possibilities.
  Inputs
  RPM1, RPM2: Two inputs for frequency (e.g. flow) measuring. Expected sensor is magnetic pickup – with
  maximal frequency range up to 8 kHz. The output values SCM Freq1, SCM Freq2 calculation use setpoints
  SCM unit: FreqRate1 and FreqRate2 - see below.
  Closed jumper divides input frequency by 16 - recommended for higher frequency (>1000Hz) measuring.
  Jumper position does not influence output value range.
  IMP1, IMP2: Two impulse inputs for integral (e.g. consumption) measuring. It is expected NPN – open collector
  (active) impulse sensor with maximal frequency range up to 60 Hz. Minimal pulse duration is 1ms. The output
  values SCM Imp1, SCM Imp2 calculation use setpoints SCM unit: TransferRate1 and TransferRate2 - see
  below.
  ID-SCM inputs wiring example
Outputs
4.1.9 ID-SCM1
  Technical data
  Power supply: internal supply from ID-DCU Industrial (8 to 36 VDC)
  Operating temperature range: -40°C to +70°C
  Number of analog outputs: 1, no galvanic separation
  Analog output refreshment: 100 ms
  Configuration in DriveConfig
      Module = SCM
      I/O – Analog outputs – SCM - AOUT1 (only)
           Source
           Low convert limit
           Hi convert limit
  Description
      ID-SCM1 can only be configured as ID-SCM.
      ID-SCM1 has only 1 analog output unlike ID-SCM which has 3 AOUTs (plus 4 values and 4 setpoints).
      Control value Speed Governor is send on ID-SCM1 AOUT - equivalent output on ID-SCM is 3rd AOUT
      (with PWM)
           Invalid values are shown in SCM values
           SCM setpoints are not used (sepoints not affects the function)
         1                              GND                     5                         UBatt
         2                             A/B IN                   6                        CAN-L
         3                              BO-A                    7                         COM
         4                              BO-B                    8                        CAN-H
  Note: It is possible to connect up to five InteliVision 5 CAN or four InteliVision 8 displays to common CAN2
  bus. The display addresses must be different in this case.
  CAN2
  Inter-controller CAN for multiple engines applications. ID-COM module is necessary. It is possible to connect
      ID-DCU Industrial controllers and/or
      IG-MU (Direct cable, analog modem or GSM modem interface) and/or
      IB-NT (Internet interface) and/or
  The data rate is selectable in two levels: 250 kBd for 200 meters line and 50 kBd for 900 meters line.
  1. Configure I-CB using I-CBEdit software. Configured I-CB behaves like fictive IS-AIN and IS-BIN units (or
      better said as Generci extensions). I-CB configuration associates selected values (from ECU database)
      received from Engine Control Unit to selected CAN addressees (fictive IS-AIN, IS-BIN inputs and outputs).
  2. Configure corresponding CONTROLLER CAN addresses in PC configuration tool.
  3. Configure separate inputs and outputs in corresponding Analog, Binary inputs, outputs in PC configuration
      tool.
  Note: In case of CAT engines, there is RS232 connection between I-CB and CCM.
 General
 To ensure proper function:
     Use grounding terminals. The InteliDrive DCU Industrial power feeding input is galvanically isolated from
     controller body, use the grounding terminal for proper grounding.
     Wiring for binary inputs and analog inputs must not be lead parallel with high voltage/current cables.
     Analog and binary inputs should be provided with shielded cables, especially when length >3m.
 Grounding
 To ensure proper function:
 The shortest possible piece of wire should be used when grounding the controller.
 Use cable min. 2,5mm2 .
 The “-“ terminal of the battery has to be properly grounded.
 Magnetic pick-up
 To ensure proper function use a shielded cable.
 Power supply
     Use min. power supply cable of 1.5 mm2 to ensure proper function.
     Maximum continuous DC power supply voltage is 36VDC.
     Maximum allowable power supply voltage is 39VDC – see chapter Technical data.
   Primary                                            Converted
   0                                                  0
   1000                                               1
Note: User curves for controller need to be configured as "CU 'sensor range' ", for example "CU 0-2500 Ω"
  Note:
  * IGS-PTM has hardware range 0-20mA but offered sensor in DriveConfig is ±20 mA
  ** IGS-PTM has hardware range 0-250 Ω only - DriveConfig offers correct sensor for I/O configuration but for
  User define input curve only sensor 0-2400 Ω.
Note: Fahrenheit sensors are supported from IS-AIN8 of sw version 2.2 only.
  Note: Controller user curves ("CU 'sensor range' ") are not possible to use for external extensions, it is
  necessary to configure standard user curve (= without "CU" on the beginning of the name of the user curve
  range).
To ensure a proper function use shielded cables, especially for length over >3 m.
                      Current
                      Measurement
                      - Jumper on pins 1-2.
                      Resistance measurement
                      - Jumper on pins 3-4.
 Note: Maximal voltage on controller Differential analog inputs AI5 to AI8 is in the range –2 to +5 VDC against
 minus power supply terminal!
Note: ID-DCU Industrial hardware jumper must correspond with software configuration.
  Configuration
  See drawing above
   Property         Value
                    Value name is displayed on the screens and in the Alarm list and History record.
                    Enter up to 14 ASCII characters.
   Name
                    Name is automatically set to Function name if function is selected from the Logical function
                    list see Function item.
   Dim              Dimension is displayed on the screens. Select dimension from the list or add a new one.
                    Select sensor from the list or create a customer sensor characteristics in User sensor
   Sensor           window. There must be corresponding analog input hardware jumper setting in InteliDrive
                    controller. See Sensor availability in table below.
                    Output value (reading) resolution. DriveConfig indicates when Resolution is out of the value
   Resolution
                    range.
   Sensor           Full output value (reading) range for 20 mA (current), 250 Ω, 2400 Ω (resistive), 1 V, 4V, 5V,
   range            100 mV (voltage) sensor.
                    Select from the list. Configure two protection levels as standard or more levels (window)
   Protection
                    protection in Expert mode.
                    Configure direction Over or Under limit when protection is activated. Options "Under
   Active           limit+Fls"  and "Over limit+Fls"  means that the protection is activated in case of Analog Input
   when             value is Under/Over the protection limit or in case that non valid value (####) is indicated on
                    the Analog Input. More details in Protections (page 64)
                    Configure protection activity: All the time or Engine running with three different adjustable
   Block type
                    delays when protectioln is active after engine start (RPM > Starting RPM).
   Bargraph
                    Bargraph starting value.
   0%
 Note: Some configuration items (e.g. Protection) stay without change when Property - Sensor is changed to
 None.
Sensors availability
 Configuration examples
     Conversion from 4-20 mA to 6.0 Bar Oil pressure sensor (Wrn+Sd protection and Oil press function)
 Note:
 HW configuration: CU 0-1 V can be used for characteristics ±1 V, but this ± characteristics can be configured to
 AI5 to AI8 inputs only!
 Sensor range (gray background) automatically follows the User sensor characteristics (zero value at the above
 picture is not important).
  Availability         Configuration
                       0 - 20mA / 600
  AI1 to AI4
  AI5 to AI8
  Analog input
  jumper = 1-2
  (current)
4 - 20mA / 100,0
  AI1 to AI4
  AI5 to AI8
   AI5 to AI8
   Analog input
   jumper = 2-3
   (voltage)
0 - 100mV / 100,00
AI5 to AI8
0 - 1200 Ω / 100
   AI1 to AI4
   AI5 to AI8
   Analog input
   jumper = 3-4
   (resistance)
  Note:
  It is possible to set up to 30 points non-linear sensor characteristics.
  Connect external resistors (voltage divider) to extend input voltage range.
Note: ECU value is available only for ECU modules and replaces a property Output type.
                                                                       Output type
           Output value
                                                 Voltage [V]            Current [mA]                  PWM [%]
                   0                                0,00                     0,0                         0,00
                10000                              10,00                     20,0                       100,00
 By not using the Convert option, we pass the source quantity directly to the output. We also have to think that
 the transfer of the entry number takes place in raw form (i.e. without decimals). In this case, we need to look at
 the values in the range of 0-10000, both on input and output. Without conversion, the physical output value is
 used as in the Output conversion limits table.
 For physical outputs, the calculator provides help in the form of automatic recalculation to the resultant
 voltage/current/percentage.
Image 4.7 Active conversion of the input variable to the output value of the physical output
Image 4.8 Active conversion of the input variable working with decimal point
     The integer input is transmitted to the ECU, where is expected to be value with one decimal place. The
     source value factually takes the same values as the target value (0-100%).
     Normalization output saves us the work of adaptation values, otherwise we would have to use PLC and
     number converted to the expected number of decimal places.
5.1.3 Protections
  Brief description of the controller's protection - basic settings and use cases.
  Note: There are visible only the first two bar graph marks for protection limits indication on ID-DCU Industrial
  screen !!!
 Under limit
 Protection is announced when it gets below the limit Level 1 (and Level 2) Limit Setpoint: Value. The delay of
 Delay Setpoint: Value can be applied to the protection. Alarm notification in the alarm list and in history
 Sensor defect when receiving invalid or no value, announces the Fls Analog input name (where Analog input
 name = will be the specific electronic (ECU, I-CB, shared) value on which the protection is configured)
 Over limit
 Protection is announced when it gets over the limit Level 1 (and Level 2) Limit Setpoint:Value. The delay of
 Delay Setpoint:Value can be applied to the protection. Alarm notification in the alarm list and in history
 Sensor defect when receiving invalid or no value, announces the Fls Analog input name
 Over limit+Fls
 Protection is announced when it gets over the limit Level 1 (and Level 2) Limit Setpoint:Value. The delay of
 Delay Setpoint:Value can be applied to the protection. Alarm notification in the alarm list and in history
 Sensor defect when receiving invalid or no value, announces the Fls Analog input name + At the same time
 the type of configured protection Wrn Analog input name or Sd Analog input name (and other types
 according to Controller options) is also declared
 Note: Thus, when the sensor fails, up to 3 alarms can occur for one value = Wrn, Sd, Fls
Idle Offset [RPM] = Idle RPM [RPM] + (Idle Offset [%] / 100) x (Nominal RPM [RPM] – Idle RPM [RPM])
 Example describing Overload protection activation, i.e. when the Engine speed falls down below yellow or
 brown limit.
  There are seven universal (free) states available in ID-DCU Industrial-3.4.0 that are not joined to any value or
  input.
      IMPORTANT: Logic for controlling the motor can't be locked in PLC. Certification authority can ask
      for access to the content locked this way.
PLC Function Selection Available Number of available blocks in ID-DCU Industrial 3.4.0
OR/AND 128x
XOR/RS 128x
Math Fc 16x
Ext Math Fc 8x
Nonlin I Fc 4x
Math AxB/C 8x
PID Bin 4x
PID Ana C 8x
Ramp 4x
Up/Down 4x
Inc/Dec 2x
Mov Avg 4x
Timer 4x
Delay 16x
Delay B 8x
Force Hist 4x
Jump 8x
Mux Const. 4x
Counter 16x
Decomp 8x
Convert 16x
3D Map 2x
Function structure
3. Go to PLC window and drag & drop PLC functional block Comp Hyst, double click the block.
4. Configure Comparator Input: click on button and select input value from the list.
 7. Drag & drop PLC functional block Ana Switch, configure Input 1 and Input 2 as PLC setpoints and edit the
     setpoint names to RPM 1 and RPM 2.
10. Go to I/O window and configure analog SCM AOUT1 as RPM out. Then configure output convert Low limit
     (0 RPM ~ 0.00V output) and High output convert limit (2000 RPM ~ 10.00V output).
All existing passwords are entered (all PLC sheets with password are unlocked)
              Any (but not all) existing passwords are entered (any, but not all PLC sheets with password
          are unlocked)
              No existing password is entered or no password exists (all PLC sheets with passwords are
          locked)
  In configuration window you can assign one of three passwords. It is necessary to enter correct password. If
  password does not exists, user is asked to create it.
      IMPORTANT: Very important parts of the control algorithm must not be locked in PLC sheets.
      Certification authorities may request their unlocking if necessary.
The principal of how shared Binary inputs and Binary outputs work is shown below.
  Shared Binary Inputs and Outputs may be used exactly in the same way as standard physical Inputs and
  Outputs. If SHBIN or SHAIN modules are configured, at least one corresponding module of SHBOUT or
  SHAOUT (respectively) is needed. If it is not configured, corresponding protection appears because SHBIN or
  SHAIN will be missing. See the figure below for more information.
      IMPORTANT: For proper function of Shared Binary and Analog Inputs and Outputs, only one
      source of Shared Binary or Analog Outputs must be configured (i.e. it is not possible to configure
      in one controller SHBOUT1 and to another one as well SHBOUT1).
A protection upon module failure can be configured in DriveConfig. See the schematic below.
      IMPORTANT: Be aware that it is necessary to use ECU list, which enables use of multiple ECU
      modules. Check and select used ECU list using this option:
      Module type - type of configured module (e.g. Standard J1939 engine support, ECON-4 speed governor
     support etc.)
      Module index – module identification number. It is used to associate alarms in alarm list and controller
     history with a particular ECU module.
      Module name - user adjustable string with up to 10 characters. Default values are ECU, ECU-1 to ECU-9,
     depending on order in which are modules added.
      Module address – user adjustable number from 0 to 255, which defines address of configured module.
     Default option is Default (X), X stands for actual address value, which comes from ESC and is assigned to
     module when the default option is used. It is recommended to use this option and use different setting only if
     the default one does not work.
     Example: Set Module address to 5, if engine CAN1 address is 5.
     Controller address – user adjustable number from 0 to 255, which defines address used by controller for
     communication with the module. Controller can use different address for communication with different
     modules. Default option is Default (X), X stands for actual address value, which comes from ESC and is
     used by controller interface for communication with module, when the default option is used. N/A is
     displayed as Controller address, if Modbus is used for communication with a module.
 Note: Do not confuse Controller address with Comms settings: Contr.address, which is different parameter
 with independent functionality.
 Note: ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
 and diagnostic messages.
      Protection upon module failure – use it to select type of alarm, which is issued if communication with
     module fails
      Add screens – use it to display/hide module related screens
      Display data as – information how are analog values displayed
      Analog inputs – Number of analog input values available with module.
 Note: Total number of available analog input values is limited to 160 with all configured modules (e.g. 4
 modules with 40 inputs would use all available inputs).
 Note: Total number of available analog output values is limited to 40 with all configured modules (e.g. 5
 modules with 8 outputs would use all available outputs).
 Note: Total number of available binary input values is limited to 160 with all configured modules (e.g. 4 modules
 with 40 inputs would use all available inputs).
 Note: Total number of available binary output values is limited to 160 with all configured modules (e.g. 4
 modules with 40 outputs would use all available outputs).
Analog inputs (4B) – Number of 4B analog input values available with module.
 Note: Total number of available 4B analog input values is limited to 20 with all configured modules (e.g. 5
 modules with 4 inputs would use all available inputs).
   Name                                                                Unit
   Engine speed                                                        RPM
   Actual torque                                                       %
   Demand torque                                                       %
   Coolant temp                                                        °C
   EngineOil temp                                                      °C
   Boost Pressure                                                      bar
   Intake Manifold Temp                                                °C
   Air Intake pressure                                                 bar
   Exhaust Gas Temp                                                    °C
   Accelerator Pedal position                                          %
   Percent Load                                                        %
   Fuel Rate                                                           L/h
   EngOil Filter Diff.Press                                            bar
   Battery Potential (Voltage)                                         V
   Fuel Delivery Pressure                                              bar
   Engine Oil level                                                    %
   Crankcase Pressure                                                  bar
   Coolant Pressure                                                    bar
   Coolant Level                                                       %
  Fault reset = accepts (confirms) diagnostic message = removes inactive message form ECU Alarm list only
  when ECU Alarm list is visible.
  Note: Fault reset button is “screen sensitive”. It is active only on selected actual controller screen.
 After-Treatment screen
 This screen is shown with configured ECU which supports Tier 4 Final/StageV. After-Treatment screen is
 automatically shown, once any of selected lamps gets active or change status. Deactivating of the lamp will not
 trigger showing the screen. The screen is then shown until operator switch it to another one. Alarm list screen
 has lower priority so even new alarm appears, After-treatment screen is still displayed. To avoid displaying
 blank screen, inactive lamps are represented by "dotted" icons. For no active lamp the screen shows all dotted
 icons. Please see examples below:
 Note: Lamp icon blinking is defined as displaying active lamp icon and inverse colored active lamp icon in
 required frequency.
6 back to Communication
  Operating conditions
   Operating temperature ID-DCU Industrial                         -20 to +70 °C
   Storage temperature                                             -30 to +80 °C
   Humidity                                                        95 % non-condensing (EN 60068-2-30)
   Flash memory data retention time                                10 years
   Protection front panel                                          IP65
   Standard conformity
   Low Voltage Directive                                           EN 61010-1:95 +A1:97
                                                                   EN 61000-6-2, October 2001
   Electromagnetic Compatibility                                   EN 61000-6-4, October 2001
                                                                   IEC 60533, Ed. 2; 1999-11
                                                                   5 – 25 Hz, ±1.6mm
   Vibration
                                                                   25 – 100 Hz, a = 4 g
   Shocks                                                          a = 200 m/s2
   Heat radiation                                                  9W
 D+ function
  Max. D+ output current                                                              300 mA
  Guaranteed level for signal Charging OK                                             80 % of supply voltage
  Note: The maximal input voltage offset is in the range from –2 to +5 VDC against controller minus power supply
  when AI5 to AI8 is used for differential voltage measuring.
                                                         ± 0 – 20 mA active
   Maximal current range
                                                         0 – 20 mA passive
   Input impedance                                       50 Ω for mA measuring
   Input impedance                                       >100 kΩ for V measuring
   Resistance measurement tolerance                      ± 0.5 % ± 2 Ω out of measured value
   Voltage measurement tolerance                         ± 0.5 % ± 1 mV out of measured value
   Current measurement tolerance                         ± 0.5 % ± 0.5 mA out of measured value
  RS232 interface
   Maximal distance                                                           10 m
   Speed                                                                      19.2 kBd
6 back to Appendix
8.1.1 Setpoints
What setpoints are:
   Setpoints are analog, binary or special data objects which are used for adjusting the controller to the specific
   environment. Setpoints are organized into groups according to their meaning. Setpoints can be adjusted from
   the controller front panel, PC, MODBUS, etc.
   Each setpoint can be protected by a password against unauthorized changes. Password protection can be
   assigned to the setpoints during the configuration procedure.
       IMPORTANT: Do not perform repeated writing of setpoints (e.g. do NOT have a MODBUS
       ’watchdog’ system where PLC periodically writes down a figure into register and then reads the
       figure). The setpoints are stored in EEPROM memory, which can be overwritten up to 100 000 times
       without risk of damage or data loss, however it may become damaged, when allowed number of
       writing cycles is exceeded!
       The issue with EEPROM memory limit is resolved from ID-DCU Industrial firmware version 2.2,
       setpoint registers were moved into another memory part of the controller.
   For full list of setpoints go to the chapter List of setpoints (page 99)
   6 back to Controller objects
 Group of setpoints:
 Act. Calls/SMS
 Group of setpoints:
 Date/Time
 Time                             153
 Date                             153
 Time Stamp Per                   153
 SummerTimeMod                    154
 EnTimeSync                       154
 Group of setpoints:
 DetCon20
 IgnRedLimit                      156
 ImmStopLimit                     157
 DecreaseRamp                     157
 TimingRedGain                    157
 DelayLoadRed                     158
 6 back to Controller
 objects
 Note: The asterisk mark “*” appears before a setpoint name (on controller screen) if the setpoint is password
 protected.
 The asterisk mark is removed only when the password is set from controller’s front panel.
 The asterisk mark is still visible on controller screen even if the password is set from InteliMonitor.
 Note: Even though one level may have been set from the front panel, the affected setpoints are not accessible
 from InteliMonitor (direct or Modem) until this level is set in InteliMonitor (direct or Modem). Setpoints opened
 from front panel are automatically closed 15 minutes after the last key has been depressed or when wrong value
 of setpoint is set.
 Note: It is possible to protect remote Start, Stop commands from InteliMonitor as well. This three level
 command protection can be configured from DriveConfig.
 EnterPassword
 Password is a four-digit number. Only setpoints associated with the entered password level can be modified.
 Use ↑ or ↓ to select the desired password and then hit enter.
     ChangePassword 1
     ChangePassword 2
     ChangePassword 3
 Note:
          Any password can be changed once that level password or higher has been entered if the change is
          made from InteliMonitor PC tool.
          Password level 3 must be entered at first to change any password if the change is made by controller
          front panel buttons.
 Access code
     Can be changed from InteliMonitor software only (Monitor – Change Access code).
     Has to be set before remote modem or SMS connection is opened.
     Can be up to 16 ASCII characters
 At first Password 3 has to be entered before the new Access code can be changed.
Note: All setpoints below can be modified from Remote panel or InteliMonitor as well.
 Mode ID
  Setpoint group             Basic settings        Related FW               3.4.0
  Range [units]              [-]
                                                   Force value
  Default value              OFF
                                                   Alternative config
  Step                       [-]
  Comm object                8315                  Related applications     AS, SS
  Description
           Mode ID [ OFF, RUN ]
       Equivalent to Controller mode changes by Mode→ or ←Mode buttons.
 Gear Teeth
  Setpoint group             Basic settings        Related FW               3.4.0
  Range [units]              1 .. 500 [-]
                                                   Force value
  Default value              120
                                                   Alternative config
  Step                       1
  Comm object                8252                  Related applications     AS, SS
  Description
       Number of teeth on the engines flywheel for the pick-up. Setpoint (RPM pickup measuring) is ignored
       when RPM is received via J1939.
 Nominal RPM
  Setpoint group             Basic settings      Related FW              3.4.0
  Range [units]              30 .. 4000 [RPM]
                                                 Force value
  Default value              1500
                                                 Alternative config
  Step                       1
  Comm object                8253                Related applications    AS, SS
  Description
  Nominal engine speed, base for Overspeed protection limit and Speed Request (page 256) percentage
  calculation.
       Note: Nominal RPM must correspond to 100 % Throttle position in ECU for correct Load sharing
       function in AS application.
 ECU Diag
  Setpoint group             Basic settings      Related FW              3.4.0
  Range [units]              [ENABLED, DISABLED, EXTERNAL]
                                                 Force value
  Default value              ENABLED                                     YES
                                                 Alternative config
  Step                       [-]
  Comm object                10353               Related applications    AS, SS
  Description
  Alarm list indication ECU Diag disabled is indicated when ECU diagnostics is disabled. The ECU
  Diagnostic is controlled by ECU DiagBlck binary input in case of setting to EXTERNAL.
 Idle/Nominal
  Setpoint group                    Basic settings         Related FW                3.4.0
  Range [units]                     [IDLE, NOMINAL, BIN.INPUT]
                                                           Force value Alternative
  Default value                     IDLE
                                                           config
  Step                              [-]
  Comm object                       10336                  Related applications      AS, SS
  Description
  Activates/deactivates the logical binary output Nominal Sw, that can be configured as J1939 output to
  switch ECU.
  BIN.INPUT: IDLE/NOMINAL mode is switched via BI IDLE (PAGE 180) (NOMINAL when closed).
       Note: Basic setting: Nominal RPM must correspond to ECU Nominal RPM for 100 % Throttle position in
       AS and 50 % in SS.
 RunHourSource
  Setpoint group             Basic settings        Related FW                 3.4.0
  Range [units]              [AUTO, INTERNAL, ECU]
                                                   Force value
  Default value              AUTO
                                                   Alternative config
  Step                       [-]
  Comm object                8630                  Related applications       AS, SS
  Description
  AUTO – controller displays valid running hours value received from any ECU module. In case of erratic
  reading use option ECU and parameter RHS Index to define module, which is source of running hours.
  Running hours value calculated by controller is used, if no valid value is received.
  INTERNAL – ID-DCU Industrial running hours statistical value is used
  ECU – controller reads running hours from selected ECU module. Parameter RHS Index is used to select
  index of module, from which controller reads running hours.
  In case no ECU support is configured, internal running hours value is used despite RunHoursSource setting.
 LightTimeOff
  Setpoint group             Basic settings        Related FW                3.4.0
  Range [units]              0 .. 250 [min]
                                                   Force value
  Default value              0
                                                   Alternative config
  Step                       1
  Comm object                10121                 Related applications      AS, SS
  Description
  Timeout for ID display backlight automatic switch off. Zero setting disables display backlight switch off.
  Backlight is automatically switched on after any key press or Alarm activation.
       Note: LightTimerOff setpoint influences the Remote panel not master controller when changed on
       Remote panel.
 Timer ON
  Setpoint group             Basic settings        Related FW                3.4.0
  Range [units]              [hh:mm:ss]
                                                   Force value
  Default value              0:00:00
                                                   Alternative config
  Step                       [-]
  Comm object                10042                 Related applications      AS, SS
  Description
  See Timer Repeat (page 108) description.
 Timer Repeat
  Setpoint group             Basic settings          Related FW               3.4.0
  Range [units]              [Never, Mon-Fri, Mon-Sat, Mon-Sun, Sat-Sun ]
                                                     Force value
  Default value              NEVER
                                                     Alternative config
  Step                       [-]
  Comm object                10045                   Related applications     AS, SS
  Description
  Logical binary output Timer Active is closed when actual time is over the Timer ON and opened when actual
  time is over Timer OFF. The function depends on Timer Repeat settings. The output is closed when
  controller is switched On and Timer settings corresponds to closed state.
Note: If the controller is connected to IB-NT, set the mode to 8C - verified stable communication speed.
 ControllerAddr
                             Communication
  Setpoint group                                   Related FW                3.4.0
                             Settings
  Range [units]              1 .. 32 [-]
                                                   Force value
  Default value              1
                                                   Alternative config
  Step                       1
  Comm object                24537                 Related applications      AS, SS
  Description
  Controller identification number. Each controller in the group has to have its own unique number. Default
  value is 1.
       Note: The InteliDrive ControllerAddr must correspond to InteliMonitor or DriveConfig communication
       setup setting when opening Direct or Modem connection.
 ECU Diag
                             Communication
  Setpoint group                                   Related FW                3.4.0
                             Settings
  Range [units]              [ENABLED, DISABLED, EXTERNAL]
                                                   Force value
  Default value              ENABLED
                                                   Alternative config
  Step                       [-]
  Comm object                10353                 Related applications      AS, SS
  Description
  This setpoint is used to disable reading of diagnostic codes from ECU if an external diagnostic tool is
  connected to engine.
  Message ECU Diag disabled is displayed in the alarm list while ECU diagnostics is disabled.
  The ECU Diagnostic is disabled/enabled using LBI:ECU DiagBlck binary input in case of setting to
  EXTERNAL.
       Note: The terminal is disconnected automatically after 5 min of inactivity and next communication
       request from the same terminal is considered as a new connection. When logging is enabled in certain
       conditions the history may be filled up with large number of records related to the communication and
       important records may be overwritten quite fast.
 RS232 MBCSpd
                             Communication
  Setpoint group                                      Related FW             3.4.0
                             Settings
  Range [units]              [9600, 19200, 38400, 57600, 115200] [bps]
                                                      Force value
  Default value              9600
                                                      Alternative config
  Step                       [-]
  Comm object                24477                    Related applications   AS, SS
  Description
  The setpoint adjusts communication speed of the RS232 interface when RS232 Mode (page 112) is set to
  Modbus.
       Note: Detailed description of Modbus protocol include some examples, see in InteliGen Communication
       guide.
 RS232 TermCSpd
                             Communication
  Setpoint group                                      Related FW             3.4.0
                             Settings
  Range [units]              [19200, 38400, 57600, 115200] [bps]
                                                      Force value
  Default value              38400
                                                      Alternative config
  Step                       [-]
  Comm object                24341                    Related applications   AS, SS
  Description
  The setpoint adjusts communication speed of the RS232 interface when RS232 Mode (page 112) is set to
  STANDARD.
       Note: If the controller is connected to IB-NT via the RS232 interface, set the speed to 57600 - the
       supported communication speed.
 RS485 Mode
                             Communication
  Setpoint group                                      Related FW             3.4.0
                             Settings
  Range [units]              [STANDARD, MODBUS, ECU LINK]
                                                      Force value
  Default value              STANDARD
                                                      Alternative config
  Step                       [-]
  Comm object                24451                    Related applications   AS, SS
  Description
  Communication protocol selection.
           STANDARD: InteliDrive (DriveConfig, InteliMonitor, Remote panel) communication protocol.
           MODBUS: Modbus RTU protocol.
           ECU LINK: Connection to an electronic-controlled engine which uses non-J1939 ECU. The proper
           ECU type must be also configured with DriveConfig.
       Note: Detailed description of Modbus protocol include some examples, see in InteliDrive
       Communication guide.
 SHxOcol Detect
                             Communication
  Setpoint group                                      Related FW             3.4.0
                             Settings
  Range [units]              [DISABLED, ENABLED]
                                                      Force value
  Default value              ENABLED
                                                      Alternative config
  Step                       [-]
  Comm object                11024                    Related applications   AS, SS
  Description
  This setpoint is used to enable/disable evaluation of collisions of virtual shared peripherial modules. A
  collision means that there is more than one source (shared outputs module) active on the CAN2 bus.
       Note: In certain situations multiple sites with bus tie breakers may need to have more shared outputs
       sources as the CAN bus line is in some points interrupted according to bus tie breakers position.
       Normally a collision would be indicated if there were more sources on the bus and this setpoint can be
       used to disable the evaluation of collisions in this special case.
Note: Step, Range and dimension depend on corresponding Analog input sensor characteristic.
 StartPCoolant
  Setpoint group             Engine params               Related FW             3.4.0
  Range [units]              0.0 .. 10.0 [Bar]
                                                         Force value
  Default value              10,0
                                                         Alternative config
  Step                       0.1
  Comm object                10138                       Related applications   AS
  Description
  Coolant pressure limit = one of the engine running indications. To activate this function any Analog input
  must be configured to Analog logical input Coolant press.
       Note: PRP only
Note: Step, Range and dimension depend on corresponding Analog input sensor characteristic.
 MaxCrank Time
  Setpoint group             Engine params            Related FW                3.4.0
  Range [units]              1 .. 200 [s]
                                                      Force value
  Default value              8
                                                      Alternative config
  Step                       1
  Comm object                8234                     Related applications      AS, SS
  Description
  Amount of time the controller will crank the engine in an attempt to start.
 CrankFailPause
  Setpoint group             Engine params            Related FW                3.4.0
  Range [units]              CMB, EME: 3 ..200 [s], AUX, PRP: 0 .. 200 [-]
                                                      Force value
  Default value              8
                                                      Alternative config
  Step                       1
  Comm object                8257                     Related applications      AS, SS
  Description
  Pause between cranking attempts.
  Together with request of unlimited start attempts was created PRESTART OVRD (PAGE 181) - activation
  means immediate transition from state Prestart to Cranking.
  Same function was applied to second push of START button. First press of START button activates state
  Prestart, second press of START button skips prestart period.
 Idle RPM
  Setpoint group             Engine params         Related FW               3.4.0
  Range [units]              Starting RPM.. Nominal RPM [RPM]
                                                   Force value
  Default value              500
                                                   Alternative config
  Step                       1
  Comm object                9946                  Related applications     AS
  Description
  Default Idle speed (should be the same as Idle speed set with engine ECU).
 Idle Time
  Setpoint group             Engine params           Related FW                3.4.0
  Range [units]              0 .. 600 [s]
                                                     Force value
  Default value              10
                                                     Alternative config
  Step                       1
  Comm object                9097                    Related applications      AS, SS
  Description
  Idle time delay starts when RPM exceeds Starting RPM.
  During the Idle time the IDLE/NOMINAL (PAGE 197) is opened and after then it is closed. IDLE/NOMINAL (PAGE
  197) opens during Cooling period (Cooling Time) again.
 PrelubrTime
  Setpoint group             Engine params           Related FW                3.4.0
  Range [units]              0 .. 600 [s]
                                                     Force value
  Default value              0
                                                     Alternative config
  Step                       1
  Comm object                8780                    Related applications      AS, SS
  Description
  This is the time the binary output Prelubrication is active. The controller will activate binary output
  Prelubrication for this amount of time, then pause for PrelubrPause, then activate again. This will continue
  the entire time the engine is not running. Function is not active in controller OFF mode.
 Stop Time
  Setpoint group             Engine params          Related FW                3.4.0
  Range [units]              0 .. 600 [s]
                                                    Force value
  Default value              60
                                                    Alternative config
  Step                       1
  Comm object                9815                   Related applications      AS, SS
  Description
  Under normal conditions the engine must certainly stop within this period. The period starts by issuing stop
  command.
 Cooling Time
  Setpoint group             Engine params          Related FW                3.4.0
  Range [units]              0 .. 600 [s]
                                                    Force value
  Default value              30
                                                    Alternative config
  Step                       1
  Comm object                8258                   Related applications      AS, SS
  Description
  Runtime of unloaded engine to cool down engine before stopping.
 D+ function
  Setpoint group             Engine params         Related FW               3.4.0
  Range [units]              [ENABLED, CHRGFAIL, DISABLED]
                                                   Force value
  Default value              DISABLED
                                                   Alternative config
  Step                       [-]
  Comm object                9683                  Related applications     AS, SS
  Description
  ENABLED: The D+ terminal is used for both functions – “running engine” detection and charge fail
  detection.
  CHRGFAIL: The D+ terminal is used for charge fail detection only
  DISABLED: The D+ terminal is not used.
       Note: Alternator magnetization current is provided independently from the parameter setting.
 BI Speed Ramp
  Setpoint group             Engine params          Related FW                3.4.0
  Range [units]              0.0 .. 100.0 [%/s]
                                                    Force value
  Default value              5
                                                    Alternative config
  Step                       0.1
  Comm object                9984                   Related applications      AS, SS
  Description
  Speed ramp setting for SPEED UP (PAGE 179) / SPEED DOWN (PAGE 178), not for Analog input request.
 EnLocalSpeed
  Setpoint group             Engine params          Related FW                 3.4.0
  Range [units]              [ENABLED, DISABLED]
                                                    Force value
  Default value              DISABLED
                                                    Alternative config
  Step                       [-]
  Comm object                10098                  Related applications       AS, SS
  Description
  ENABLED: Speed Request (page 256) is defined by Local Speed (page 123) setpoint that can be
  modified by Fast edit function from front panel (4 sec Enter, / ¯, Enter).
  DISABLED: Speed Request (page 256)t is changed via SPEED UP (PAGE 179) / SPEED DOWN (PAGE 178)
  or via REQUESTED RPM (PAGE 236), see Speed Request (page 256) t charts for (page 257) and (page
  257) modes.
 Local Speed
  Setpoint group             Engine params          Related FW                 3.4.0
  Range [units]              0.0 .. 100.0 [%]
                                                    Force value
  Default value              0.0
                                                    Alternative config
  Step                       0.1
  Comm object                9948                   Related applications       AS, SS
  Description
       Setpoint specifies Speed Request (page 256) when EnLocalSpeed (page 123) = ENABLED. Setpoint
       can be changed as standard setpoint or by Fast edit function: press Enter for 4 sec, / ¯ set value, press
       Enter to confirm, see Speed Request (page 256) charts for PRP and AUX / EME / HRB modes.
 RunOnlyBlkDel1
  Setpoint group             Engine protect          Related FW                3.4.0
  Range [units]              0 .. 60 [s]
                                                     Force value
  Default value              10
                                                     Alternative config
  Step                       1
  Comm object                10023                   Related applications      AS, SS
  Description
  This parameter adjusts delay after engine start when alarms configured as RunOnlyBlkDel1 (i.e. "running
  only", group #1) are started to be evaluated. The "running only" alarms are not beeing evaluated while the
  engine is not running or then, after start, while the adjusted delay is running.
  For details see drawing, which is part of RunOnlyBlkDel3 (page 125) description.
 RunOnlyBlkDel2
  Setpoint group             Engine protect          Related FW                3.4.0
  Range [units]              0 .. 60 [s]
                                                     Force value
  Default value              20
                                                     Alternative config
  Step                       1
  Comm object                10024                   Related applications      AS, SS
  Description
  This parameter adjusts delay after engine start when alarms configured as RunOnlyBlkDel2 (i.e. "running
  only", group #2) are started to be evaluated. The "running only" alarms are not beeing evaluated while the
  engine is not running or then, after start, while the adjusted delay is running.
  For details see drawing, which is part of RunOnlyBlkDel3 (page 125) description.
       Note:
       Engine running state =
       RPM > Starting RPM (page 115) or
       Analog input Oil Press > Starting POil (page 116) or
       Analog input Coolant Press > StartPCoolant (page 116) (PRP only) or
       Active Binary input RunIndication1 or
       Active Binary input RunIndication2 or
       Active Binary input RunIndication3.
 BinInp Delay 2
  Setpoint group             Engine protect         Related FW                 3.4.0
  Range [units]              0 .. 60 [s]
                                                    Force value
  Default value              5
                                                    Alternative config
  Step                       1
  Comm object                10132                  Related applications       AS, SS
  Description
  Binary input protection is activated when input is closed for longer time than BinInp delay 2. To use this filter,
  binary input protection Delay must be configured in DriveConfig to BinInp delay 2. For details see BinInp
  Delay 3 (page 127) description.
 ForceBlockDel2
  Setpoint group                    Engine protect        Related FW                  3.4.0
  Range [units]                     0 .. 60 [s]
                                                          Force value Alternative
  Default value                     0
                                                          config
  Step                              1
  Comm object                       10570                 Related applications        AS, SS
  Description
  Delay for Force block protection activation after binary input Force Block 2 is opened. Protection
  deactivation is without delay. Protection is activated/deactivated independent on engine running or not
  running state.
 Overspeed
  Setpoint group             Engine protect          Related FW             3.4.0
  Range [units]              0 .. 200 [%]
                                                     Force value
  Default value              110
                                                     Alternative config
  Step                       1 % of Nominal RPM (page 104)
  Comm object                8263                    Related applications   AS, SS
  Description
  Threshold for engine overspeed protection.
 UnderSpeed
  Setpoint group             Engine protect          Related FW             3.4.0
  Range [units]              0 .. Starting RPM (page 115) [RPM]
                                                     Force value
  Default value              30
                                                     Alternative config
  Step                       1
  Comm object                8260                    Related applications   AS, SS
  Description
  Underspeed alarm is activated when engine is running and actual RPM is below the UnderSpeed threshold.
 Batt > V
  Setpoint group             Engine protect           Related FW             3.4.0
  Range [units]              Batt <V.. 40.0 [V]
                                                      Force value
  Default value              30.0
                                                      Alternative config
  Step                       0.1
  Comm object                9587                     Related applications   AS, SS
  Description
  Warning level for battery over voltage.
 Batt < V
  Setpoint group             Engine protect           Related FW             3.4.0
  Range [units]              8.0 .. Batt >V [V]
                                                      Force value
  Default value              8.0
                                                      Alternative config
  Step                       0.1
  Comm object                8387                     Related applications   AS, SS
  Description
  Warning level for low battery voltage.
 OverloadSpLim
  Setpoint group             Engine protect     Related FW               3.4.0
  Range [units]              0.0 .. 100.0 [%]
                                                Force value
  Default value              20.0
                                                Alternative config
  Step                       0.1
  Comm object                9950               Related applications     AS
  Description
  Engine overload protection limit. See Function description details (page 63).
 Overload Del
  Setpoint group             Engine protect     Related FW               3.4.0
  Range [units]              0 .. 600 [s]
                                                Force value
  Default value              10
                                                Alternative config
  Step                       1
  Comm object                9947               Related applications     AS
  Description
  Delay for Overload RPM protection limit.
 ECUAlarmMode
  Setpoint group             Engine protect         Related FW              3.4.0
  Range [units]              [DEFAULT, ALARM ONLY]
                                                    Force value
  Default value              DEFAULT
                                                    Alternative config
  Step                       [-]
  Comm object                15813                  Related applications    AS, SS
  Description
  DEFAULT: COMMON W RN (PAGE 194) is activated , if ECU alarm is received by controller.
  ALARM ONLY: COMMON W RN (PAGE 194) is not activated, if ECU alarm is received by controller.
 RPM dependent Oil pressure and Coolant pressure protections are available in AS (propulsion) application only.
 Both protections are by default set to Protection block type = RunOnlyBlkDel1 (Engine running - block delay 1).
 There are two setpoints for linear Warning limit, two for Shutdown limit and one for delay. Setpoints adjusting
 step and range depends on corresponding sensor characteristics.
 Note: The particular RPM dependent protection is fully disabled if both xxxIdlexxx and xxxNomxxx parameters
 are set to value 0,0. I.e. the protection is not activated even if measured value is negative (e.g. when there is a
 wrong sensor calibration).
 OPIdleRPMWrn
                             RPMdep protection (AS
  Setpoint group                                     Related FW               3.4.0
                             only)
  Range [units]              0.0 .. 10.0 [Bar]
                                                     Force value
  Default value              0.0
                                                     Alternative config
  Step                       0.1
  Comm object                10140                   Related applications     AS
  Description
  Linear Warning characteristic is defined by two points for Idle RPM (page 118) and Nominal RPM (page
  104). OPIdleRPMWrn defines oil pressure warning level at idle speed.
 OPIdleRPMSd
                             RPMdep protection (AS
  Setpoint group                                     Related FW             3.4.0
                             only)
  Range [units]              0.0 .. 10.0 [Bar]
                                                     Force value
  Default value              0.0
                                                     Alternative config
  Step                       0.1
  Comm object                10142                   Related applications   AS
  Description
  Linear Shutdown characteristic is defined by two points for Idle RPM (page 118) and Nominal RPM (page
  104). OPIdleRPMSd defines oil pressure shutdown level at idle speed. For details see OilPrRPMdel (page
  135) description.
 OPNomRPMSd
                             RPMdep protection (AS
  Setpoint group                                     Related FW             3.4.0
                             only)
  Range [units]              0.0 .. 10.0 [Bar]
                                                     Force value
  Default value              0.0                                            YES
                                                     Alternative config
  Step                       0.1
  Comm object                10143                   Related applications   AS
  Description
  Linear Shutdown characteristic is defined by two points for Idle RPM (page 118) and Nominal RPM (page
  104). OPNomRPMSd defines oil pressure shutdown level at nominal speed. For details see OilPrRPMdel
  (page 135) description.
  To activate RPM dependent oil pressure protection any analog value has to be linked with OIL PRESS (PAGE
  235).
       Note: RPM dependent oil pressure protection is fix configured Protection block type = Engine running
       only with RunOnlyBlkDel1 delay.
 CPIdleRPMWrn
                             RPMdep protection (AS
  Setpoint group                                       Related FW             3.4.0
                             only)
  Range [units]              0.0 .. 10.0 [Bar]
                                                       Force value
  Default value              0.0                                              YES
                                                       Alternative config
  Step                       0.1
  Comm object                10144                     Related applications   AS
  Description
  Linear Warning characteristic is defined by two points for Idle RPM (page 118) and Nominal RPM (page
  104). CPIdleRPMWrn defines coolant pressure warning level at idle speed. For details see CoolPrRPMdel
  (page 137) description.
 CPIdleRPMSd
                             RPMdep protection (AS
  Setpoint group                                     Related FW             3.4.0
                             only)
  Range [units]              0.0 .. 10.0 [Bar]
                                                     Force value
  Default value              0.0
                                                     Alternative config
  Step                       0.1
  Comm object                10146                   Related applications   AS
  Description
  Linear Shutdown characteristic is defined by two points for Idle RPM (page 118) and Nominal RPM (page
  104). CPIdleRPMSd defines coolant pressure shutdown level at idle speed. For details see CoolPrRPMdel
  (page 137) description.
 CPNomRPMSd
                             RPMdep protection (AS
  Setpoint group                                     Related FW             3.4.0
                             only)
  Range [units]              0.0 .. 10.0 [Bar]
                                                     Force value
  Default value              0.0
                                                     Alternative config
  Step                       0.1
  Comm object                10147                   Related applications   AS
  Description
  Linear Shutdown characteristic is defined by two points for Idle RPM (page 118) and Nominal RPM (page
  104). CPNomRPMSd defines coolant pressure shutdown level at nominal speed. For details see
  CoolPrRPMdel (page 137) description.
  To activate RPM dependent coolant pressure protection any analog value has to be linked with COOLANT
  PRESS (PAGE 235).
       Note: RPM dependent coolant pressure protection is fix configured Protection block type = Engine
       running only with RunOnlyBlkDel1 delay.
 Load Int
  Setpoint group             Load sharing           Related FW              3.4.0
  Range [units]              0.0 .. 100.0 [%]
                                                    Force value
  Default value              10.0
                                                    Alternative config
  Step                       0.1
  Comm object                8713                   Related applications    AS
  Description
  Relative Integration factor of the load sharing loop.
 Clutch Del
  Setpoint group             Load sharing           Related FW              3.4.0
  Range [units]              0.0 .. 60.0 [s]
                                                    Force value
  Default value              5
                                                    Alternative config
  Step                       0.1
  Comm object                9949                   Related applications    AS
  Description
  Time between the clutch is switched on/off and the load sharing function is activated.
 ClutchMaxSpeed
  Setpoint group             Load sharing            Related FW             3.4.0
  Range [units]              ClutchMinSpeed .. 100.0 [%]
                                                     Force value
  Default value              100.0
                                                     Alternative config
  Step                       0.1
  Comm object                10097                   Related applications   AS
  Description
  Clutch can be switched on if ClutchMinSpeed < RPM < ClutchMaxSpeed. Limits are in % of Requested
  speed. See Function description details (page 63).
       Note: 0.0 % corresponds to (Idle speed + Idle offset) value, 100.0 % corresponds to Nominal speed.
 Back Up Speed2
  Setpoint group                    Load sharing            Related FW                3.4.0
  Range [units]                     0.0 .. 100.0 [%]
                                                            Force value Alternative
  Default value                     50.0
                                                            config
  Step                              0.1
  Comm object                       10523                   Related applications      AS
  Description
  See Load sharing block diagram (page 144) - the setpoint value is used instead of Speed Request
  (page 256) in loadsharing state, if BACK UP SPEED1 (PAGE 173) is active and REQUESTED RPM (PAGE 236)
  reading via analog input is out of range (sensor fail is detected).
 MaxClStrtPer
  Setpoint group             Load sharing              Related FW              3.4.0
  Range [units]              0 .. 600 [s]
                                                       Force value
  Default value              60
                                                       Alternative config
  Step                       1
  Comm object                10102                     Related applications    AS
  Description
  Engine clutch start protection. Start fail alarm is activated, if engine running condition is not detected during
  MaxClStrPer delay time after CLUTCH CONNECT (PAGE 196) is closed.
 RQSP Aver
  Setpoint group             Load sharing          Related FW             3.4.0
  Range [units]              0 .. 1000 [%]
                                                   Force value
  Default value              5
                                                   Alternative config
  Step                       1
  Comm object                10136                 Related applications   AS
  Description
  Average value calculated from all Speed Request values of controllers running in Loadsharing mode together
  (on the same CAN2 bus). See Load sharing block diagram (page 144).
                                                                                                    ID-DCU
        Value             Description                                     Dimension InteliMonitor Industrial
                                                                                                    display
        Loadsharing group
                          Average of Requested RPM values
        RQSP aver         calculated from all controllers participating   %             YES         YES
                          in loadsharing
        RQSP              RQSP aver value after ramp specified by
                                                                          %             YES         YES
        ramp              Loadsharing: RQSP Ramp setpoint
        ThrottlePos       Throttle position                               %             YES         YES
        Engine values group
        Speed
                          Speed request                                   %             YES         NO
        Request
       Note: The maximal ThrottlePos difference between parallel operating engines (due to Load sharing
       function) is 1.5 %.
       ThrottlePos output (request to EMS) is switched to be equal to the Speed Request (page 256) after
       other engines clutches are disconnected (no load sharing, only one engine powers the shaft).
 AIN2 Offset
  Setpoint group             Analog inputs         Related FW             3.4.0
  Range [units]              -32767 .. 32767 [-]
                                                   Force value
  Default value              0
                                                   Alternative config
  Step                       [-]
  Comm object                8407                  Related applications   AS, SS
  Description
  Adjustable offset for AIN2 for calibrating purposes.
 AIN3 Offset
  Setpoint group             Analog inputs         Related FW             3.4.0
  Range [units]              -32767 .. 32767 [-]
                                                   Force value
  Default value              0
                                                   Alternative config
  Step                       [-]
  Comm object                8467                  Related applications   AS, SS
  Description
  Adjustable offset for AIN3 for calibrating purposes.
 AIN5 Offset
  Setpoint group             Analog inputs         Related FW             3.4.0
  Range [units]              -32767 .. 32767 [-]
                                                   Force value
  Default value              0
                                                   Alternative config
  Step                       [-]
  Comm object                8794                  Related applications   AS, SS
  Description
  Adjustable offset for AIN5s for calibrating purposes.
 AIN6 Offset
  Setpoint group             Analog inputs         Related FW             3.4.0
  Range [units]              -32767 .. 32767 [-]
                                                   Force value
  Default value              0
                                                   Alternative config
  Step                       [-]
  Comm object                8795                  Related applications   AS, SS
  Description
  Adjustable offset for AIN6 for calibrating purposes.
 AIN8 Offset
  Setpoint group             Analog inputs         Related FW             3.4.0
  Range [units]              -32767 .. 32767 [-]
                                                   Force value
  Default value              0
                                                   Alternative config
  Step                       [-]
  Comm object                11599                 Related applications   AS, SS
  Description
  Adjustable offset for AIN8 for calibrating purposes.
       Note: Both SMS and E-MAIL active call types are supported in conjunction with InteliBridge-NT, if
       cellular interface is used (WAN connection mode = Cellular). E-MAIL only is supported, if Ethernet
       interface is used (WAN connection mode = Ethernet).
       Note: To receive DATA active call run InteliMonitor – Type of connection = Active call. InteliMonitor
       Active call window contains list of received AID files. Each list item contains Engine name, Date, Time,
       ID serial number.
       Note: Both SMS and E-MAIL active call types are supported in conjunction with InteliBridge-NT, if
       cellular interface is used (WAN connection mode = Cellular). E-MAIL only is supported, if Ethernet
       interface is used (WAN connection mode = Ethernet).
       Note: To receive DATA active call run InteliMonitor – Type of connection = Active call. InteliMonitor
       Active call window contains list of received AID files. Each list item contains Engine name, Date, Time,
       ID serial number.
 AcallCH1-Addr
  Setpoint group             Act. Calls/SMS           Related FW               3.4.0
  Range [units]              [-]
                                                      Force value
  Default value              0
                                                      Alternative config
  Step                       [-]
  Comm object                9597                     Related applications     AS, SS
  Description
  Address for channel 1 active call. Each above message type has either phone number or e-mail address
  associated with it.
       Note: Both SMS and E-MAIL active call types are supported in conjunction with InteliBridge-NT, if
       cellular interface is used (WAN connection mode = Cellular). E-MAIL only is supported, if Ethernet
       interface is used (WAN connection mode = Ethernet).
       Note: To receive DATA active call run InteliMonitor – Type of connection = Active call. InteliMonitor
       Active call window contains list of received AID files. Each list item contains Engine name, Date, Time,
       ID serial number.
 AcallCH2-Addr
  Setpoint group             Act. Calls/SMS           Related FW               3.4.0
  Range [units]              [-]
                                                      Force value
  Default value              0
                                                      Alternative config
  Step                       [-]
  Comm object                9598                     Related applications     AS, SS
  Description
  Address for channel 2 active call. Each above message type has either phone number or e-mail address
  associated with it.
 Num Rings AA
  Setpoint group             Act. Calls/SMS         Related FW               3.4.0
  Range [units]              1 .. 30 [-]
                                                    Force value
  Default value              3
                                                    Alternative config
  Step                       1
  Comm object                24512                  Related applications     AS, SS
  Description
  Number of rings prior to open modem connection from PC to controller.
       Note: Num Rings AA change is not accepted immediately, but only after controller is switched on or
       when modem is connected to controller.
 A.C.Multiplier
  Setpoint group             Act. Calls/SMS         Related FW               3.4.0
  Range [units]              1 .. 250 [-]
                                                    Force value
  Default value              3
                                                    Alternative config
  Step                       1
  Comm object                24505                  Related applications     AS, SS
  Description
  Setpoint specifies number of attempts to open Active call connection when phone line is engaged.
       Note: Timeout for connection is 90 sec and after 120 sec controller starts the next attempt. Incoming
       calls are blocked when controller is trying to send active call message.
 Date
  Setpoint group             Date/Time              Related FW             3.4.0
  Range [units]              [DD:MM:YY]
                                                    Force value
  Default value              8.6.2006
                                                    Alternative config
  Step                       [-]
  Comm object                24553                  Related applications   AS, SS
  Description
  Actual date adjustment
        DISABLED            The automatic change to daylight saving time and back is disabled.
                            The automatic change is enabled, the current season is winter and the controller is
        WINTER
                            located in the northern hemisphere.
                            The automatic change is enabled, the current season is summer and the controller is
        SUMMER
                            located in the northern hemisphere.
                            The automatic change is enabled, the current season is winter and the controller is
        WINTER-S
                            located in the southern hemisphere.
                            The automatic change is enabled, the current season is summer and the controller is
        SUMMER-S
                            located in the southern hemisphere.
 EnTimeSync
  Setpoint group             Date/Time                 Related FW                3.4.0
  Range [units]              [DISABLED, ENABLED]
                                                       Force value
  Default value              DISABLED
                                                       Alternative config
  Step                       [-]
  Comm object                24217                     Related applications      AS, SS
  Description
           The setpoint is used to enable Time synchronization function with InteliGen-NT and InteliSys-NT
           controllers over CAN2 bus.
           The synchronization is just unidirectional from InteliGen-NT or InteliSys-NT controller into InteliDrive
           DCU Industrial, not vice versa.
 FreqRate1
  Setpoint group             SCM unit           Related FW               3.4.0
  Range [units]              0 .. 500 [-]
                                                Force value
  Default value              0
                                                Alternative config
  Step                       1
  Comm object                10902              Related applications     AS, SS
  Description
  Conversion constant (number of pulses for one RPM) for ID-SCM RPM1 frequency input - SCM Freq1
  value. Frequency range max. 8 kHz.
 FreqRate2
  Setpoint group             SCM unit           Related FW               3.4.0
  Range [units]              0 .. 500 [-]
                                                Force value
  Default value              0
                                                Alternative config
  Step                       1
  Comm object                10903              Related applications     AS, SS
  Description
  Conversion constant (number of pulses for one RPM) for ID-SCM RPM2 frequency input - SCM Freq2
  value. Frequency range max. 8 kHz.
 TransferRate1
  Setpoint group             SCM unit           Related FW               3.4.0
  Range [units]              0 .. 500 [-]
                                                Force value
  Default value              0
                                                Alternative config
  Step                       1
  Comm object                10906              Related applications     AS, SS
  Description
  Conversion ratio (number of pulses for increase by 1) for ID-SCM IMP 1 impulse input / SCM Imp1 value.
  Frequency range max. 60 Hz.
           Example: To measure actual water flow in liters (or cubic meters) per minute set FreqRate = 10 [ ]
           when sensor gives 10 pulses per liter (or cubic meters).
           Example: To measure total water consumption in liters (or cubic meters) set TransferRate = 100 [ ]
           when sensor gives 100 pulses per 1 liter (or cubic meter).
 Dedekind
 IgnRedLimit
  Setpoint group             DetCon20                Related FW              3.4.0
  Range [units]              0 .. 255 [-]
                                                     Force value
  Default value              10
                                                     Alternative config
  Step                       1
  Comm object                10299                   Related applications    AS, SS
  Description
  Ignition reduction limit is knocking value above which the engine is considered to be knocking. If the value is
  exceeded, DetCon20 binary output ENGINE KNOCKING is activated and the values assigned to the timing
  reduction are altered.
 DecreaseRamp
  Setpoint group             DetCon20             Related FW                3.4.0
  Range [units]              0.0 .. 100.0 [%/s]
                                                  Force value
  Default value              30.0 %/s
                                                  Alternative config
  Step                       0.1 %/s
  Comm object                10300                Related applications      AS, SS
  Description
  Decrease ramp specifies rate at which is the timing reduction signal (analog output) decreased as soon as
  knocking drops below the IgnRedLimit (page 156) (ignition reduction limit).
 TimingRedGain
  Setpoint group             DetCon20             Related FW                3.4.0
  Range [units]              0.0 .. 100.0 [%]
                                                  Force value
  Default value              40.0 %
                                                  Alternative config
  Step                       0.1 %
  Comm object                10301                Related applications      AS, SS
  Description
  Timing reduction gain influences rate at which timing reduction signal (analog output) is amplified when
  knocking is detected.
       Note: If you need to lock only some of the external terminals, you can use following inputs:
                ACCESSLOCKCOM1 (PAGE 163)
                ACCESSLOCKCOM2 (PAGE 164)
                ACSLOCKCAN2(1) (PAGE 164)
                ACSLOCKCAN2(2) (PAGE 165)
                ACSLOCKCAN2(3) (PAGE 165)
                ACSLOCKCAN2(4) (PAGE 166)
                ACSLOCKCAN2(5) (PAGE 166)
 AccessLockCOM1
  Related FW                 3.4.0                    Related applications          AS, SS
  Comm object                789
  Description
  If the input is closed, following commands received via RS232 interface (e.g. from InteliMonitor or from a
  remote display) are inactive:
           Remote engine start, stop commands
           No setpoints can be adjusted
           Controller mode (e.g. OFF-RUN) cannot be changed
           Fault reset and horn reset commands
           All other commands (e.g. change of a Remote Switch state)
           It is possible to list Setpoints, Values and History
           Binary input functions are without change
       Engine can be started, stopped via Binary inputs (e.g. REMOTE START (PAGE 1)) or via front panel
       buttons.
       Note: When this Access Lock input is active, it is still possible to initiate programming from a remotely
       connected DriveConfig.
 AcsLockCAN2(1)
  Related FW                 3.4.0                    Related applications     AS, SS
  Comm object                794
  Description
  If the input is closed, following commands received via CAN2 with address #1 (e.g. from InteliMonitor or
  from a remote display) are inactive:
           Remote engine start, stop commands
           No setpoints can be adjusted
           Controller mode (e.g. OFF-RUN) cannot be changed
           Fault reset and horn reset commands
           All other commands (e.g. change of a Remote Switch state)
           It is possible to list Setpoints, Values and History
           Binary input functions are without change
       Engine can be started, stopped via Binary inputs (e.g. REMOTE START (PAGE 1)) or via front panel
       buttons.
       Note: When this Access Lock input is active, it is still possible to initiate programming from a remotely
       connected DriveConfig.
 AcsLockCAN2(3)
  Related FW                 3.4.0                    Related applications     AS, SS
  Comm object                796
  Description
  If the input is closed, following commands received via CAN2 with address #3 (e.g. from InteliMonitor or
  from a remote display) are inactive:
           Remote engine start, stop commands
           No setpoints can be adjusted
           Controller mode (e.g. OFF-RUN) cannot be changed
           Fault reset and horn reset commands
           All other commands (e.g. change of a Remote Switch state)
           It is possible to list Setpoints, Values and History
           Binary input functions are without change
       Engine can be started, stopped via Binary inputs (e.g. REMOTE START (PAGE 1)) or via front panel
       buttons.
       Note: When this Access Lock input is active, it is still possible to initiate programming from a remotely
       connected DriveConfig.
 AcsLockCAN2(5)
  Related FW                 3.4.0                    Related applications     AS, SS
  Comm object                1056
  Description
  If the input is closed, following commands received via CAN2 with address #5 (e.g. from InteliMonitor or
  from a remote display) are inactive:
           Remote engine start, stop commands
           No setpoints can be adjusted
           Controller mode (e.g. OFF-RUN) cannot be changed
           Fault reset and horn reset commands
           All other commands (e.g. change of a Remote Switch state)
           It is possible to list Setpoints, Values and History
           Binary input functions are without change
       Engine can be started, stopped via Binary inputs (e.g. REMOTE START (PAGE 1)) or via front panel
       buttons.
       Note: When this Access Lock input is active, it is still possible to initiate programming from a remotely
       connected DriveConfig.
 Force Block 1
  Related FW                 3.4.0                  Related applications     AS, SS
  Comm object                16
  Description
  Active input blocks protections that are configured as “Force Block 1” Prot. block type. Corresponding
  setpoint is ForceBlockDel1.
 Force Block 2
  Related FW                 3.4.0                  Related applications     AS, SS
  Comm object                17
  Description
  Active input blocks protections that are configured as “Force Block 2” Prot. block type. Corresponding
  setpoint is ForceBlockDel2.
 Force Block 3
  Related FW                 3.4.0                  Related applications     AS, SS
  Comm object                18
  Description
  Active input blocks protections that are configured as “Force Block 3” Prot. block type. Corresponding
  setpoint is ForceBlockDel3.
 Horn Reset
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                153
  Description
  Binary input Horn Reset is level sensitive.
 Remote OFF
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                12
  Description
  Controller is switched to OFF mode if input is closed and back to previous mode after is opened. Input is not
  active in LOC (Local) mode. Active binary input Remote OFF is indicated by “L” character in the right upper
  corner on ID-DCU Industrial screen.
       Note: Remote OFF will switch controller to OFF mode even if the ACCESSLOCK INT (PAGE 163) or
       ACCESSLOCK EXT (PAGE 161) is active or Controller mode is password protected.
 Remote HRB
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                14
  Description
  Controller is switched to HRB mode if closed and back to previous mode if opened. Input is not active in
  LOC (Local) mode.
 Remote On/Off
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                161
  Description
  CLOSE LOAD (PAGE 1) is closed/opened depends on the state of Remote On/Off binary input when engine
  RPM is over MinLoadSpeed (page 130). Remote On/Off is not active in LOC mode.
       Logical Binary Outputs that are deactivated (directly or indirectly) when Emerg. manual is active could be
       (only if they are available in controler FW): Starter, Fuel solenoid, Prestart, Cooling pump, Stop solenoid,
       Stop pulse, Speed up, Speed dn, AVR up, AVR dn, Ignition, Ventilation, Idle/Nominal, Prelubr pump,
       ECU PwrRelay, Ready for load, Stand-by ready, Operational, Ready, Not Ready, CrankProcedure,
       Starting, Idle run, Running
 EmergencyStop1 / EmergencyStop2
  Related FW                 3.4.0                     Related applications        AMF, MRS
  Comm object                286
  Description
  If the input is activated, engine shutdown is immediately performed. However, the controller behavior is
  slightly different compared to other shutdown alarms:
           Outputs Cooling pump and Prelubrication are deactivated as well.
           This input cannot be overriden with the input Sd override.
       Note: Because of safety reasons it is recommended to configure this input as Normally closed and use a
       NC switch.
       Note: Because of safety reasons it is recommended to configure this input as Normally closed and use a
       NC switch.
 EmergencyStop2
  Related FW                 3.4.0                   Related applications    AS, SS
  Comm object                928
  Description
  If the input is activated, engine shutdown is immediately performed. However, the controller behavior is
  slightly different compared to other shutdown alarms:
           COOLING PUMP (PAGE 200) and PRELUBRICATION (PAGE 198) are deactivated as well.
           This input cannot be overriden with the input Sd override.
       Note: Because of safety reasons it is recommended to configure this input as Normally closed and use a
       NC switch.
 Remote Start
  Related FW                 3.4.0                   Related applications    AS, SS
  Comm object                156
  Description
  External “edge sensitive” request for engine start. Binary input is active in all AUX, EME, HRB and PRP
  modes and inactive in LOC (Local) mode. There is only one start attempt, use REMREPSTART (PRP ONLY)
  (PAGE 172) or Blackout Start (AUX, EME and HRB) binary input for repetitive starting procedure using
  Crank Attempts (page 118) and CrankFailPause (page 117) until the engine does not start. Unsuccessful
  start is recorded to Alarm list and History. The second edge on Binary input Remote Start skips the Idle time
  when engine is running in Idle state.
  Binary input Remote Start signal is equivalent to ID-DCU Industrial front panel Start button.
 Reg Inhib
  Related FW                 3.4.0                  Related applications       AS, SS
  Comm object                837
  Description
  Active signal inhibits automatic DPF filter regeneration.
 RegenForce
  Related FW                 3.4.0                  Related applications       AS, SS
  Comm object                836
  Description
  Active signal inhibits automatic DPF filter regeneration.
       Note: Crank Attempts (page 118) is not followed if Sd Override is active, crank attempts number is
       then unlimited in case of Blackout/RemRep Start.
 Back Up Speed1
  Related FW                 3.4.0                          Related applications     AS
  Comm object                159
  Description
  If input is active and Logical Analog input Requested RPM is not valid (out of range, sensor fail),
  ThrottlePos (page 262) is set to Back Up Speed1 (page 140) value. ThrottlePos (page 262) = 0.0 %
  when analog request is out of range and Binary input Back Up Speed is not active.
 Back Up Speed3
  Related FW                 3.4.0                  Related applications      AS
  Comm object                171
  Description
  If input is active and Logical Analog input Requested RPM is not valid (out of range, sensor fail),
  ThrottlePos (page 262) is set to Back Up Speed1 (page 140) value. ThrottlePos (page 262) = 0.0 %
  when analog request is out of range and Binary input Back Up Speed is not active.
 Fire Speed
  Related FW                 3.4.0                  Related applications      AS
  Comm object                160
  Description
  If active, clutch is disconnected and ThrottlePos (page 262) is set to FireAlarmSpeed (page 123), the
  ThrottlePos value change is influenced by ramp specified by RQSP Ramp (page 143).
 Rem Clutch
  Related FW                 3.4.0                  Related applications      AS
  Comm object                183
  Description
  If active closes binary output Clutch Connect – see CLUTCH CONNECT (PAGE 196).
 StartBlocking1
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                68
  Description
  OR logical function of all StartBlocking Logical Binary inputs forces controller NotReady state ( i.e. disables
  engine start). It is active in LOC (Local) mode as well.
 StartBlocking3
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                581
  Description
  OR logical function of all StartBlocking Logical Binary inputs forces controller NotReady state ( i.e. disables
  engine start). It is active in LOC (Local) mode as well.
 StartBlocking4
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                582
  Description
  OR logical function of all StartBlocking Logical Binary inputs forces controller NotReady state ( i.e. disables
  engine start). It is active in LOC (Local) mode as well.
 StartBlocking5
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                583
  Description
  OR logical function of all StartBlocking Logical Binary inputs forces controller NotReady state ( i.e. disables
  engine start). It is active in LOC (Local) mode as well.
 Load Blocking
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                182
  Description
  Active input disables the Close load function. No influence when Binary output Close load is closed.
 RunIndication2
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                47
  Description
  Binary input can be used for engine running indication e.g. via Oil pressure contact. Active Running
  indication blocks engine start (to avoid starter damage).
  Engine running state = RPM > Starting RPM (page 115) or
  Analog input Oil pressure > Starting POil (page 116) or
  Active Binary input RunIndication1 or
  Active Binary input RunIndication2 or
  Active Binary input RunIndication3.
 RunIndication3
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                48
  Description
  Binary input can be used for engine running indication e.g. via Oil pressure contact. Active Running
  indication blocks engine start (to avoid starter damage).
  Engine running state = RPM > Starting RPM (page 115) or
  Analog input Oil pressure > Starting POil (page 116) or
  Active Binary input RunIndication1 or
  Active Binary input RunIndication2 or
  Active Binary input RunIndication3.
 Loaded
  Related FW                 3.4.0                  Related applications      SS
  Comm object                162
  Description
  Binary input function for loaded engine indication.
 EnClutchStart
  Related FW                 3.4.0                  Related applications      AS
  Comm object                163
  Description
  Binary input activates Engine start via clutch. Engine is started by the other running engine via closed clutch
  - binary output Clutch Connect. See MaxClStrtPer (page 141) protection setpoint.
 Sd Override
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                44
  Description
  Blocks all protections except Overspeed (page 129), Emergency Stop and protections configured as “Sd
  override” (=Sprinkler).
           All alarms are detected
           Alarms are recorded on the controller Alarm list screen
           Alarm are recorded into History
           Enabled Active calls remains active
           Controller front panel engine RED LED blinks or lights
       Note: The setpoint Crank Attempts is not followed if Sd Override is active, crank attempts number is
       then unlimited in case of Blackout Start.
Note: Minimal Speed Up and Speed Down pulse duration is 110 ms to be accepted by controller.
Note: Minimal Speed Up and Speed Down pulse duration is 110 ms to be accepted by controller.
 ECU FltReset
  Related FW                 3.4.0                  Related applications       AS, SS
  Comm object                166
  Description
  Binary input for ECU Alarm acknowledge (level sensitive) has the same function as controller front panel
  Fault reset button (screen sensitive - active only in ECU Alarm list screen).
       Note: Activation of ECU Fault reset will affect InteliDrive DCU Industrial controller only, no reset
       request is sent to ECU. There is separated acknowledge input for Alarms – see Binary input FAULT
       RESET (PAGE 168).
 BI Second RPM
  Related FW                 3.4.0                 Related applications       AS, SS
  Comm object                168
  Description
  This input changes state of SECOND RPM SW (SS ONLY) (PAGE 202) that can be configured as J1939 output
  to change ECU mode. Input is active only when Speed Select (page 106)t = BIN.INPUT.
 BI Idle
  Related FW                 3.4.0                 Related applications       AS, SS
  Comm object                169
  Description
  This input changes state of IDLE/NOMINAL (PAGE 197) that can be configured as J1939 output to change
  ECU mode. Input is active only when Idle/Nominal (page 105) = BIN.INPUT.
 Rem Start/Stop
  Related FW                 3.4.0                 Related applications       AS, SS
  Comm object                172
  Description
  Rem Start/Stop is level signal that activates engine start when closed and stop after is opened. It is inactive
  in LOC (Local) mode.
  It is not possible to stop engine by panel Stop button and by Remote Stop (page 172) when Rem Start/Stop
  is active. Rem Start/Stop input can be configured to Binary output Timer active to enable engine automatic
  start/stop function – see Timer Repeat (page 108).
       Note: Engine “Start fail” is Warning (level 1) protection and does not block another start when Rem
       Start/Stop is still closed. To prevent unlimited number of starts – configure on START FAIL (PAGE 225)
       Sd protection.
Note: Engine stays running when Rem Start/Stop is opened in controller LOC (Local) mode.
 ClutchBlocking
  Related FW                 3.4.0               Related applications      PRP
  Comm object                182
  Description
  ClutchBlocking can block CLUTCH CONNECT (PAGE 196). Active input is indicated in Alarm list as “Clutch
  Blocking” message.
 ModeL Button
  Related FW                 3.4.0               Related applications      AS, SS
  Comm object                200
  Description
  Input simulates the panel ← Mode button
 ModeR Button
  Related FW                 3.4.0               Related applications      AS, SS
  Comm object                201
  Description
  Input simulates the panel Mode → button.
 Page Button
  Related FW                 3.4.0               Related applications      AS, SS
  Comm object                202
  Description
  Input simulates the panel Page button.
 Up Button
  Related FW                 3.4.0              Related applications    AS, SS
  Comm object                204
  Description
  Input simulates the panel ↑-button.
 Down Button
  Related FW                 3.4.0              Related applications    AS, SS
  Comm object                205
  Description
  Input simulates the panel ↓ button.
 ECU DiagBlck
  Related FW                 3.4.0              Related applications    AS, SS
  Comm object                269
  Description
  Input controls ECU Diagnostic functionality in case of setting ECU Diag = EXTERNAL.
 Clear DayCons
  Related FW                 3.4.0              Related applications    AS, SS
  Comm object                220
  Description
  Rising edge clears Day consumption counter.
 Memo1 Trigger
  Related FW                 3.4.0                Related applications    AS, SS
  Comm object                584
  Description
  Rising edge forces to fill register Statistics: Memo1 by MEMORY1 (PAGE 240) actual value. Memo1
  Statistics value can be set or resetted by InteliMonitor command.
 Memo2 Trigger
  Related FW                 3.4.0                Related applications    AS, SS
  Comm object                585
  Description
  Rising edge forces to fill register Statistics: Memo2 by MEMORY2 (PAGE 241) actual value. Memo2 Statistics
  value can be set or resetted by InteliMonitor command.
 User Mask 1
  Related FW                  3.4.0                     Related applications      AS, SS
  Comm object                 567
  Description
  This input allows user to activate chosen function in ScreenEditor (tool inside DriveConfig) for particular
  screen instrument. User may choose from the following functions:
       Note: This function can be used to "swap" between two different screen instruments when certain
       conditions are fulfilled. Logical binary inputs Mask 1..4 can be used to define any custom condition for
       this "swapping" function.
 User Mask 2
  Related FW                  3.4.0                     Related applications      AS, SS
  Comm object                 568
  Description
  This input allows user to activate chosen function in ScreenEditor (tool inside DriveConfig) for particular
  screen instrument. User may choose from the following functions:
       Note: This function can be used to "swap" between two different screen instruments when certain
       conditions are fulfilled. Logical binary inputs Mask 1..4 can be used to define any custom condition for
       this "swapping" function.
       Note: This function can be used to "swap" between two different screen instruments when certain
       conditions are fulfilled. Logical binary inputs Mask 1..4 can be used to define any custom condition for
       this "swapping" function.
 User Mask 4
  Related FW                  3.4.0                     Related applications      AS, SS
  Comm object                 570
  Description
  This input allows user to activate chosen function in ScreenEditor (tool inside DriveConfig) for particular
  screen instrument. User may choose from the following functions:
       Note: This function can be used to "swap" between two different screen instruments when certain
       conditions are fulfilled. Logical binary inputs Mask 1..4 can be used to define any custom condition for
       this "swapping" function.
 AccessLock int
  Related FW            3.4.0                         Related applications             AS, SS
  Comm object           2
  Description
  The output is closed if there is a communication failure with the controller front panel.
  The timeout for communication failure is 5 seconds.
       Note: When communication with any terminal is lost, the LBO: HORN (PAGE 193) is closed and a history
       record is written. This history record can be enabled / disabled by the setpoint LB/UART Log (page
       111).
 AccessLockCOM1
  Related FW            3.4.0                         Related applications             AS, SS
  Comm object           2
  Description
  The output is closed if there is a communication failure with the RS232 interface.
  The timeout for communication failure is 5 seconds.
       Note: When communication with any terminal is lost, the LBO: HORN (PAGE 193) is closed and a history
       record is written. This history record can be enabled / disabled by the setpoint LB/UART Log (page
       111).
 AcsLockCAN2(1)
  Related FW            3.4.0                        Related applications              AS, SS
  Comm object           2
  Description
  The output is closed if there is a communication failure with CAN2 with address #1.
  The timeout for communication failure of CAN2 interface is adjusted by the setpoint CAN2 Timeout (page
  110).
       Note: When communication with any terminal is lost, the LBO: HORN (PAGE 193) is closed and a history
       record is written. This history record can be enabled / disabled by the setpoint LB/UART Log (page
       111).
 AcsLockCAN2(2)
  Related FW            3.4.0                        Related applications              AS, SS
  Comm object           2
  Description
  The output is closed if there is a communication failure with CAN2 with address #2.
  The timeout for communication failure of CAN2 interface is adjusted by the setpoint CAN2 Timeout (page
  110).
       Note: When communication with any terminal is lost, the LBO: HORN (PAGE 193) is closed and a history
       record is written. This history record can be enabled / disabled by the setpoint LB/UART Log (page
       111).
 AcsLockCAN2(4)
  Related FW            3.4.0                       Related applications          AS, SS
  Comm object           2
  Description
  The output is closed if there is a communication failure with CAN2 with address #4.
  The timeout for communication failure of CAN2 interface is adjusted by the setpoint CAN2 Timeout (page
  110).
       Note: When communication with any terminal is lost, the LBO: HORN (PAGE 193) is closed and a history
       record is written. This history record can be enabled / disabled by the setpoint LB/UART Log (page
       111).
 AcsLockCAN2(5)
  Related FW            3.4.0                       Related applications          AS, SS
  Comm object           2
  Description
  The output is closed if there is a communication failure with CAN2 with address #5.
  The timeout for communication failure of CAN2 interface is adjusted by the setpoint CAN2 Timeout (page
  110).
       Note: When communication with any terminal is lost, the LBO: HORN (PAGE 193) is closed and a history
       record is written. This history record can be enabled / disabled by the setpoint LB/UART Log (page
       111).
 AmberLamp
  Related FW            3.4.0                       Related applications          AS, SS
  Comm object           1828
  Description
  Indicates that engine issued a warning.
 DPF Lamp
  Related FW                               3.4.0      Related applications             AS, SS
  Comm object                              1831
  Description
  Active signal indicates that DPF (Diesel Particulate Filter) is starting to overfill with soot because the
  system is unable to undertake an automatic active regeneration. It starts flashing when the DPF is nearly
  full, engine power may be reduced.
 HEST Lamp
  Related FW            3.4.0                         Related applications             AS, SS
  Comm object           1373
  Description
  Indicates High Exhaust System Temperature (HEST). It may be active during DPF regeneration to indicate
  higher than normal exhaust temperatures.
 Horn
  Related FW            3.4.0                         Related applications             AS, SS
  Comm object           1
  Description
  Binary output for Horn, Buzzer alarm acoustic indication. Output is automatically switched off after Horn
  Timeout (page 124). Horn is active unlimited time (until Fault reset) when Horn timeout = 0.
 Alarm
  Related FW            3.4.0                         Related applications             AS, SS
  Comm object           2
  Description
  The output closes if any alarm is activated and opens after Fault reset even if the Alarm is still active.
 Common Wrn
  Related FW            3.4.0                            Related applications       AS, SS
  Comm object           3
  Description
  The output closes when any Warning alarm is active. Output opens when all Wrn alarms disappear and Fault
  reset is pressed (no Wrn alarm in Alarm list).
 Common Sd
  Related FW            3.4.0                            Related applications       AS, SS
  Comm object           4
  Description
  The output closes when any Shut-down alarm is active. Output opens when all Sd alarms disappear and
  Fault reset is pressed (no Sd alarm in Alarm list).
 Common Cd
  Related FW            3.4.0                            Related applications       AS, SS
  Comm object           257
  Description
  The output closes when any Cool-down alarm is active. Output opens when all Cd alarms disappear and
  Fault reset is pressed (no Cd alarm in Alarm list).
 Common Fls
  Related FW            3.4.0                            Related applications       AS, SS
  Comm object           6
  Description
  The output closes when any Sensor fail alarm is active. Output opens when all Fls alarms disappear and
  Fault reset is pressed (no Fls alarm in Alarm list).
 OFF Mode
  Related FW            3.4.0                       Related applications       AS, SS
  Comm object           17
  Description
  TThe output is closed in controller OFF mode.
 Controller mode
  Related FW            3.4.0                       Related applications       PRP, AUX, HRB
  Comm object           9887
  Description
  PRP Mode (PRP only) The output is closed in controller PRP mode.
  AUX Mode (AUX only) The output is closed in controller AUX mode.
  HRB Mode (CMB only) The output is closed in controller HRB mode.
 Not In LOC
  Related FW            3.4.0                       Related applications       AS, SS
  Comm object           258
  Description
  The output is closed, if LOC (Local) mode is not selected.
 In LOC
  Related FW            3.4.0                       Related applications       AS, SS
  Comm object           259
  Description
  The output is closed, if LOC (Local) mode is selected.
 Clutch Connect
  Related FW            3.4.0                       Related applications            AS
  Comm object           261
  Description
  Output is closed if REM CLUTCH (PAGE 174) is active or controller front panel I/0 button is pressed and actual
  engine RPM is between: ClutchMinSpeed and ClutchMaxSpeed.
  Output stays closed even if the RPM goes out of limits above. Can’t be opened by button when REM
  CLUTCH (PAGE 174) is closed. BI Rem clutch is not active in LOC (Local) mode.
 ClutchBtToggle
  Related FW            3.4.0                       Related applications            AS, SS
  Comm object           1461
  Description
  The first press of 0/1- panel Close Load button activates the new LBO ClutchBtToggle, the second press
  deactivates it, The function operates in all engine modes and states and can be used for some independent
  PLC function when standard Clutch function is not used.
  Existing function of panel Close load button 0/1(LBO Close Load) is without change.
  Close Load function works for remote access from DriveMonitor, Modbus, Modem, ... as well.
 HEST Lamp
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1373
  Description
  Indicates High Exhaust System Temperature (HEST). It may be active during DPF regeneration to indicate
  higher than normal exhaust temperatures.
 Starter
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           24
  Description
  Closed output energizes the engine starter.
 Prelubrication
  Related FW            3.4.0                              Related applications       AS, SS
  Comm object           49
  Description
  Periodic prelubrication function – see PrelubrTime (page 119) and PrelubrPause (page 120).
 Ready To Start
  Related FW            3.4.0                         Related applications           AS, SS
  Comm object           262
  Description
  Engine ready for start indication: no start blocking alarm is active. Output is active in LOC (Local) mode as
  well (even if can’t be started by binary inputs).
 Ready To Load
  Related FW            3.4.0                         Related applications           AS, SS
  Comm object           67
  Description
  Output closes if the engine is in Running state and can be loaded. Opens in Cooling state. Active only if
  RPM > MinLoadSpeed (page 130).
 RedStopLamp
  Related FW            3.4.0                         Related applications           AS, SS
  Comm object           1829
  Description
  Active when continued operation could result in damage to exhaust system, but actual reason of the alarm
  may not be exhaust system related.
 Engine Running
  Related FW            3.4.0                         Related applications           AS, SS
  Comm object           263
  Description
  It activates when RPM rises above Starting RPM (page 115) and opens when RPM=0.
 Unload
  Related FW            3.4.0                         Related applications        AS, SS
  Comm object           264
  Description
  1 sec (fix) pulse prior to transfer from RUNNING (PAGE 231) to COOLING (PAGE 200) state.
 Cooling
  Related FW            3.4.0                         Related applications        AS, SS
  Comm object           74
  Description
  Closes in cooling state, opens after engine stop.
 Fuel Solenoid
  Related FW            3.4.0                         Related applications        AS, SS
  Comm object           22
  Description
  Closed output opens the fuel solenoid. Adjustable to DIESEL or GAS. See also the Fuel Solenoid (page
  122) setpoint description.
 Cooling Pump
  Related FW            3.4.0                         Related applications        AS, SS
  Comm object           40
  Description
  The output closes when engine starts and opens AfterCoolTime (page 121) delayed after stop the engine.
     Not Used
       Related FW            3.4.0                      Related applications           SS
       Comm object           265
       Description
       The output is closed/opened with rising edge of REM START /STOP (PAGE 180) (or I/0 front panel button)
       when engine is in Running state and engine RPM is over MinLoadSpeed. Output opens when RPM is
       below MinLoadSpeed (page 130). Close load can be opened remotely (e.g. from InteliMonitor) when
       REMOTE ON/OFF (PAGE 168) is closed.
 Droop Sw
  Related FW            3.4.0                        Related applications          AS, SS
  Comm object           266
  Description
  The output is closed when Governor Mode (page 105) = DROOP or Governor Mode = BIN.INPUT and
  corresponding BI DROOP (PAGE 180) is closed. This logical output (Source) can be configured to
  corresponding J1939 output (e.g. Governor Mode in Volvo-IndustrialD12 Aux).
           Example:
           Nominal speed at full load: 1500 rpm
           Min offset: -50 rpm
           Max offset: +50 rpm
           "Nominal speed offset" = 0 × 3A = 58 % => speed offset = +8 rpm
           Referens speed to governor at full load = 1500 + 8 = 1508 rpm
 Stop Pulse
  Related FW            3.4.0                          Related applications       AS, SS
  Comm object           25
  Description
  1 sec pulse is generated in the beginning of Stop procedure.
 DEF LowLvlamp
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1833
  Description
  Active signal indicates low level of Diesel Exhaust Fluid (DEF). It starts flashing when the DEF tank is
  nearly empty (e.g. when the level is 10 %), engine power may be reduced.
 Alarm Blink
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           275
  Description
  Function is based on COMMON ALARM (PAGE 194) - stays closed when any alarm is active (at least one item
  in Alarm list) and opens for 2 sec when any new Alarm is activated. The first activation is delayed 2 sec. No
  Fault reset influence when at least one alarm is active. Output opens when Alarm list is empty.
 Idle Sw
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           276
  Description
  The output is closed when Idle/Nominal (page 105) = NOMINAL or Idle/Nominal = BIN.INPUT and
  corresponding BI IDLE (PAGE 180) is closed. This logical output (Source) can be configured to corresponding
  J1939 output (e.g. Idle Speed Select in Volvo-IndustrialD12 Aux).
 Logical 0
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           26
  Description
  Constant value that can be configured to any output (e.g. CurrentGear in Volvo-PRP).
 Logical 1
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           27
  Description
  Constant value that can be configured to any output (e.g. CurrentGear in Volvo-PRP).
 Timer Active
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           277
  Description
  Binary output Timer Active is closed and opened according to Timer setpoints setting. Engine starts and
  stops when this output is connected (configured) to REM START /STOP (PAGE 180). Timer is active in all
  controller modes include OFF mode.
 Alarm BlinkAct
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           278
  Description
  It follows the panel Red LED. Starts blink after any (Wrn, Sd) Alarm is activated, light after Fault reset,
  disappear after Fault reset when no alarm is active.
 Common SdO
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           251
  Description
  Indicates any active protection configured as Shut down Override.
 Derating Alarm
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           279
  Description
  Power derating indication, information received from communication bus.
 ECU PowerRelay
  Related FW                        3.4.0                 Related applications        AS, SS
  Comm object                       116
  Description
  The output closes at the beginning of prestart and opens if the engine shall be stopped. This output can be
  used to indicate when the ECU should be powered up i.e. only while the engine is running.
  This output also influences evaluation of communication failure with ECU and related alarms from analog
  inputs read from the ECU. If the output is configured (which means configured on physical binary output or
  VBOUT output), announcement of the communication error is blocked if the engine is switched off including
  the stopping procedure as shown in the figure.
       Note: The LBO must be configured on physical binary output or VBOUT output. It is not enough to
       configure it as a PLC input for example.
       Note: If the LBO: ECUPowerRelay is used to energize ECU unit during the start procedure, the
       initialization of the ECU unit might take slightly longer time and Wrn CommError(x)/Sd CommError(x)
       might appear. In this case is recommended to use ECUCOMFAIL BLCK (PAGE 169), please see this LBI.
 StartButtEcho
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           281
  Description
  1 sec pulse is generated after panel Start button is pressed.
 FltResButtEcho
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           283
  Description
  1 sec pulse is generated after panel Fault reset button is pressed. The pulse is generated only in case that
  Alarm List screen is displayed on the controller, i.e. in the time of possibility to acknowledge alarms.
 HrnResButtEcho
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           284
  Description
  1 sec pulse is generated after panel Horn reset button is pressed.
 ClutchButtEcho
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           285
  Description
  1 sec pulse is generated after panel I/0 button is pressed.
Note: Horn reset function works for remote access from DriveMonitor, Modbus, Modem, ... as well
 MalfunctLamp
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object           1832
  Description
  Indicates that emissions related engine fault code is active.
 ActLoadShar
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object           449
  Description
  Indication of active Load sharing.
 AirFlaps
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object           620
  Description
  AirFlaps output is activated with engine starting (when controller enters state Cranking) and it is deactivated
  5 s after engine stopping.
 User Button 1
  Related FW            3.4.0                          Related applications            AS, SS
  Comm object           726
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 2
  Related FW            3.4.0                          Related applications            AS, SS
  Comm object           727
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 3
  Related FW            3.4.0                          Related applications            AS, SS
  Comm object           728
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 4
  Related FW            3.4.0                          Related applications            AS, SS
  Comm object           729
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 6
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           751
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 7
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           752
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 8
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1087
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 9
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1088
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 11
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1090
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 12
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1091
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 13
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1092
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 14
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           1093
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 User Button 16
  Related FW            3.4.0                           Related applications        AS, SS
  Comm object           1095
  Description
  InteliVision function buttons can be assigned to these LBOs User Button 1 .. 16. The configuration of
  button’s functionality is done via ScreenEditor feature in DriveConfig PC application.
 RegenInhibit
  Related FW            3.4.0                           Related applications        AS, SS
  Comm object           960
  Description
  Indicates that automatic DPF filter regeneration is inhibited using REG INHIB (PAGE 172).
 RegenInhibLamp
  Related FW            3.4.0                           Related applications        AS, SS
  Comm object           1834
  Description
  Indicates that diesel particulate filter regeneration is inhibited.
 RegenForce
  Related FW            3.4.0                           Related applications        AS, SS
  Comm object           961
  Description
  Indicates that automatic DPF filter regeneration is forced using REGENFORCE (PAGE 172).
 RemoteControl1
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           141
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 RemoteControl2
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           142
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 RemoteControl3
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           143
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 RemoteControl4
  Related FW            3.4.0                         Related applications            AS, SS
  Comm object           144
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 RemoteControl6
  Related FW            3.4.0                        Related applications      AS, SS
  Comm object           146
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 RemoteControl7
  Related FW            3.4.0                        Related applications      AS, SS
  Comm object           147
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 RemoteControl8
  Related FW            3.4.0                        Related applications      AS, SS
  Comm object           148
  Description
  Those eight LBOs can be handled from InteliMonitor Remote switch window. This way can operator directly
  handle controller binary outputs or other e.g. PLC functions.
 CommError 10
  Related FW            3.4.0                   Related applications   AS, SS
  Comm object           2007
  Description
  J1939 communication fail indication.
 Bw RPU StopSol
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           324
  Description
  ID-RPU STOP SOLENOID (PAGE 198) - Broken wire indication.
       Note: Binary output Stop solenoid and Fuel solenoid broken wire is indicated in open state.
 ECU AlarmList
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           303
  Description
  Output is closed when at least one item is in ECU Alarm list.
 UnivState 1
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           185
  Description
  Universal states 1 to Universal states 7 indication. See Universal states (page 28) description.
 UnivState 2
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           186
  Description
  Universal states 1 to Universal states 7 indication. See Universal states (page 28) description.
 UnivState 3
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           187
  Description
  Universal states 1 to Universal states 7 indication. See Universal states (page 28) description.
 UnivState 5
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           189
  Description
  Universal states 1 to Universal states 7 indication. See Universal states (page 28) description.
 UnivState 6
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           190
  Description
  Universal states 1 to Universal states 7 indication. See Universal states (page 28) description.
 UnivState 7
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           191
  Description
  Universal states 1 to Universal states 7 indication. See Universal states (page 28) description.
 EcuDiagBlocked
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object
  Description
  Output is closed when ECU Diag (page 104) = DISABLED.
 PLC Message 1
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           181
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 3
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           183
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 4
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           184
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 5
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           372
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 6
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           373
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 7
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           374
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 9
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           530
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 10
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           531
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 11
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           532
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 12
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           533
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 13
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           534
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 15
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           792
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 PLC Message 16
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           793
  Description
  The output is closed while the alarm generated by the PLC block Force Prot is present in the alarm list.
 Emergency Stop
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object           260
  Description
  Indication of EMERGENCYSTOP1 / EMERGENCYSTOP2 (PAGE 170).
 Engine RPM
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object
  Description
  Engine speed state indication. Output is closed when no RPM is received from J1939 (sensor fail) or
  Overspeed or Under speed is detected.
 Overload
  Related FW            3.4.0                        Related applications           AS, SS
  Comm object
  Description
  Active overload protection activation.
 ChrgAlternFail
  Related FW            3.4.0                        Related applications         AS, SS
  Comm object
  Description
  Charger fail detection. D+ output current is limited to cca 300 mA.
  Guaranteed level for signal Charging OK = 90 % of supply voltage.
  There are three possible conditions for stop engine cranking: Starting RPM, StartingPOil and D+ function
  (when ENABLED). Starter goes off when any of these conditions becomes valid.
 Stop Fail
  Related FW            3.4.0                        Related applications         AS, SS
  Comm object
  Description
  Engine stop fail indication. Stop fail: engine does not reach 0 RPM after stop command within Stop Time
  (page 120).
 Overspeed
  Related FW            3.4.0                        Related applications         AS, SS
  Comm object           779
  Description
  Engine overspeed indication.
 Underspeed
  Related FW            3.4.0                        Related applications         AS, SS
  Comm object
  Description
  Under speed indication.
 Battery Flat
  Related FW            3.4.0                          Related applications             AS, SS
  Comm object
  Description
  ID-DCU Industrial controller reset during Cranking state (see Crank Attempts (page 118)).
 Battery Volt
  Related FW            3.4.0                          Related applications             AS, SS
  Comm object           1293
  Description
  Indication when battery voltage (ID-DCU Industrial power supply) is out of Batt > V (page 130) and Batt <
  V (page 130) limits.
 WrnService Time
  Related FW            3.4.0                          Related applications             AS, SS
  Comm object
  Description
  Output is closed when Service time (count down) = 0.
       Note: History record and Alarm list indication is activated as well.
 Not Lubricated
  Related FW            3.4.0                          Related applications             AS, SS
  Comm object
  Description
  The lubrication cycle (PrelubrTime) is not finished after controller Switch on or return from OFF mode.
 OP RPMdep
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object
  Description
  Out of Oil pressure RPM dependent limit indication.
 CP RPMdep
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object
  Description
  Out of Cooling pressure RPM dependent limit indication.
 Battery A volt
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object
  Description
  It is closed when the battery A voltage of RPU is out of limits: Engine protection: Batt >V, Batt <V, Batt V
  del.
 Battery B volt
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object
  Description
  It is closed when the battery B voltage of RPU is out of limits: Engine protection: Batt >V, Batt <V, Batt V
  del.
 Start Blocking
  Related FW            3.4.0                     Related applications   AS, SS
  Comm object
  Description
  Start blocking indication.
 ClutchBlocking
  Related FW            3.4.0                     Related applications   AS, SS
  Comm object
  Description
  Clutch blocking indication.
 Running
 Engine running state indication.
 Overspeed
 Engine overspeed indication.
 OilPress
 Oil pressure out of limit indication.
 OilTemp
 Oil temperature out of limit indication.
 CoolantTemp
 Coolant temperature out of limit indication.
 Coolant Level
 Coolant level out of limit indication.
 Running
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object           67
  Description
  Engine running state indication.
 Overspeed
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object           779
  Description
  Engine overspeed indication.
 OilPress
  Related FW            3.4.0                        Related applications            AS, SS
  Comm object           521
  Description
  Oil pressure out of limit indication.
 CoolantLevel
  Related FW            3.4.0                   Related applications   AS, SS
  Comm object
  Description
  Coolant level out of limit indication.
 Engine Speed
  Related FW                 3.4.0                  Related applications     AS, SS
  Comm object                8
  Description
  RPM value from ECU - J1939.
 Oil Press
  Related FW                 3.4.0                  Related applications     AS, SS
  Comm object                9
  Description
  Engine oil pressure, which is displayed at the first controller screen.
       Note: Configure OIL PRESS (PAGE 235) (LAI card in DriveConfig) to display the value at the first
       controller screen.
 Oil Temp
  Related FW                 3.4.0                  Related applications     AS, SS
  Comm object                77
  Description
  Universal input for engine oil temperature.
 Coolant Press
  Related FW                 3.4.0                  Related applications     AS
  Comm object                66
  Description
  Running indication and speed dependable protection in PRP.
 Fuel Level
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                78
  Description
  Analog input for fuel level in percentage.
 Requested RPM
  Related FW                 3.4.0                  Related applications      AS, SS
  Comm object                68
  Description
  AI influences directly Speed Request (page 256) register when configured without ramp. In the case of
  sensor fail (out of range) is Speed request = 0.0 % for PRP and 50.0 % (=Nominal RPM) for AUX. There is
  expected range of values 0.0 … 100.0 % for this Logical Analog input.
  See Speed Request (page 256) charts for (page 257) and (page 257) modes.
 Engine Torque
  Related FW                 3.4.0                  Related applications      AS
  Comm object                69
  Description
  Actual engine torque in %, received from J1939.
 FuelConsump
  Related FW                 3.4.0                Related applications      AS, SS
  Comm object                116
  Description
  Analog input for engine fuel consumption value [L/h], which is used for MomAvgFlCon L (page 278)
  calculation
      1. Default configuration
               ID / AIN_Function = Oil Press; MainScrAna1
               ID / AIN2_Function = Coolant Temp; MainScrAna2
      2. To display e.g. value from AIN3 “AirTemp1” instead “OilPress” (the first position) and AIN4
           “AirTemp2” instead “CoolTemp” value:
             a. Select AIN3 Property Function = MainScrAna1
             b. Select AIN4 Property Function = MainScrAna2
             c. Create new language (in DriveConfig Languages) based on English
             d. Rename (in DriveConfig Translator / Other texts) text “OilPress” to “AirTemp1” in the newly
                  created language
             e. Rename (in DriveConfig Translator / Other texts) text “CoolTemp” (no space between) to
                  “AirTemp2” in the newly created language
              f. Switch the ID-DCU Industrial controller into newly created and modificated language (Enter +
                  Page, Page, select the new language by up/down arrows, Enter)
       Note: Translate text “OilPress” and “CoolTemp” - no space between words because of similar texts (e.g.
       Coolant Temp, etc. are located on other screens).
      1. Default configuration
               ID / AIN_Function = Oil Press; MainScrAna1
               ID / AIN2_Function = Coolant Temp; MainScrAna2
      2. To display e.g. value from AIN3 “AirTemp1” instead “OilPress” (the first position) and AIN4
           “AirTemp2” instead “CoolTemp” value:
             a. Select AIN3 Property Function = MainScrAna1
             b. Select AIN4 Property Function = MainScrAna2
             c. Create new language (in DriveConfig Languages) based on English
             d. Rename (in DriveConfig Translator / Other texts) text “OilPress” to “AirTemp1” in the newly
                  created language
             e. Rename (in DriveConfig Translator / Other texts) text “CoolTemp” (no space between) to
                  “AirTemp2” in the newly created language
              f. Switch the ID-DCU Industrial controller into newly created and modificated language (Enter +
                  Page, Page, select the new language by up/down arrows, Enter)
       Note: Translate text “OilPress” and “CoolTemp” - no space between words because of similar texts (e.g.
       Coolant Temp, etc. are located on other screens).
 Cold Temp 1
  Related FW                 3.4.0                 Related applications       AS, SS
  Comm object                56
  Description
  If there is an additional terminal board between a thermocouple sensor and the IS-AIN8 (TC) module and
  there is a significant temperature difference between this terminal board and the module, it is necessary to
  measure the temperature at this terminal board and use this temperature for the thermocouple compensation
  instead of the internal temperature of the module.
  Cold Temp 1 Logical Analog input is intended for measurement of this thermocouple compensation
  temperature for the IS-AIN8 (TC) module with index #1, Cold Temp 2 corresponds to IS-AIN8 (TC) module
  with index #2 etc.
       Note: Thermocouples without internal compensation "Thermo(nc)..." must be used for this case.
 Cold Temp 3
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                58
  Description
  If there is an additional terminal board between a thermocouple sensor and the IS-AIN8 (TC) module and
  there is a significant temperature difference between this terminal board and the module, it is necessary to
  measure the temperature at this terminal board and use this temperature for the thermocouple compensation
  instead of the internal temperature of the module.
  Cold Temp 1 Logical Analog input is intended for measurement of this thermocouple compensation
  temperature for the IS-AIN8 (TC) module with index #1, Cold Temp 2 corresponds to IS-AIN8 (TC) module
  with index #2 etc.
       Note: Thermocouples without internal compensation "Thermo(nc)..." must be used for this case.
 Cold Temp 4
  Related FW                 3.4.0                 Related applications      AS, SS
  Comm object                59
  Description
  If there is an additional terminal board between a thermocouple sensor and the IS-AIN8 (TC) module and
  there is a significant temperature difference between this terminal board and the module, it is necessary to
  measure the temperature at this terminal board and use this temperature for the thermocouple compensation
  instead of the internal temperature of the module.
  Cold Temp 1 Logical Analog input is intended for measurement of this thermocouple compensation
  temperature for the IS-AIN8 (TC) module with index #1, Cold Temp 2 corresponds to IS-AIN8 (TC) module
  with index #2 etc.
       Note: Thermocouples without internal compensation "Thermo(nc)..." must be used for this case.
 Cyl Temp 2
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                18
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 3
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                19
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 4
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                20
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 5
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                21
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 6
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                22
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 8
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                24
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 9
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                25
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 10
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                26
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 11
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                27
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 12
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                28
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 14
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                30
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 15
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                31
  Description
  Analog inputs for engine Cylinder temperature measuring.
 Cyl Temp 16
  Related FW                 3.4.0              Related applications   AS, SS
  Comm object                32
  Description
  Analog inputs for engine Cylinder temperature measuring.
Expert field is now empty. This field is visible in Expert mode only.
4. Above step configured protection are now visible in Expert field and corresponding limits as well.
 5. Add the third protection: “+” button, and edit Property (e.g. Wrn, Under, ….) Any protection limit/delay can be
     set to Constant (then value is fixed, specified in line below) and can not be changed by customer (not
     included in setpoint list) … or …
Use “+” button to add Delay setpoint and set/change name value and limits.
Note: Configure this UnivState to some Binary output and modify Bin output Name.
 Oil pressure and Water temperature on the first ID controller screen indication
 1. Reading from ID-DCU Industrial analog inputs
logical function
8.1.5 Values
What values are:
   Values (or quantities) are analog or binary data objects, measured or computed by the controller, that are
   intended for reading from the controller screen, PC, MODBUS, etc. Values are organized into groups according
   to their meaning.
For full list of values go to the chapter List of values (page 254).
 EngRPMfiltered
  Value group                 Basic settings       Related FW                 3.4.0
  Resolution [units]          1 [RPM]
  Comm object                 11401                Related applications       AS, SS
  Description
  Filtered current engine speed for nice displaying without nozzle oscillations.
       Note: limit is defined by the value of the communication object of specified number
 Mode Loc
  Value group                 Basic settings       Related FW                 3.4.0
  Resolution [units]          1 [-]
  Comm object                 10135                Related applications       AS, SS
  Description
  Text string value containing "LOC" or empty text string depending on Activated or Deactivated LOC mode.
 SpeedReq RPM
  Value group                 Engine values      Related FW                3.4.0
  Resolution [units]          1 [RPM]
  Comm object                 10006              Related applications      AS, SS
  Description
           Application AS conversion 0.0 % = 0.3 * NominalRPM, 100.0 % = 1.1 * NominalRPM
           Application SS conversion 0.0 % = 0.9 * NominalRPM, 100.0 % = 1.1 * NominalRPM
  In the case of sensor fail (out of range) is Sped request = 0 for PRP and 50 % (=Nominal RPM) for SS
  configuration.
 T Cyl Max
  Value group                 Engine values     Related FW             3.4.0
  Resolution [units]          1 [°C]
  Comm object                 10526             Related applications   AS, SS
  Description
  Detected maximal temperature value from CYL TEMP 1 (PAGE 243) .. CYL TEMP 16 (PAGE 245).
 T Cyl Min
  Value group                 Engine values     Related FW             3.4.0
  Resolution [units]          1 [°C]
  Comm object                 10527             Related applications   AS, SS
  Description
  Detected minimal temperature value from CYL TEMP 1 (PAGE 243) .. CYL TEMP 16 (PAGE 245).
 Oil Press
  Value group                 Engine values     Related FW             3.4.0
  Resolution [units]          1 [Bar]
  Comm object                 10268             Related applications   AS, SS
  Description
  Internal value corresponding to OIL PRESS (PAGE 235).
 Cool Temp
  Value group                 Engine values     Related FW             3.4.0
  Resolution [units]          1 [°C]
  Comm object                 10267             Related applications   AS, SS
  Description
  Internal value corresponding to COOLANT TEMP (PAGE 236).
 Fuel Level
  Value group                 Engine values       Related FW                 3.4.0
  Resolution [units]          0,1 [%]
  Comm object                 11570               Related applications       AS, SS
  Description
  Internal value corresponding to logical inputFUEL LEVEL (PAGE 236).
 PM Status
  Value group                 Engine values       Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 16071               Related applications       AS, SS
  Description
  A value belonging to a particular Volvo Penta device - Power Module. Communication over the J1587
  interface.
  Data message PID 150 - PTO Engagement Control Status
  Identifies the current state of the input and output functions used to control the engagement of PTO devices.
           PrimBatActive binary status
           SecBatActive binary status
           D12ExhTemp binary status
           D12SeaWatPres binary status
           EMSSupply10A binary status
           ExtraSupply7A binary status
           30Supply7A binary status
 Sec Battery
  Value group                 Engine values         Related FW             3.4.0
  Resolution [units]          0,1 [V]
  Comm object                 12154                 Related applications   AS, SS
  Description
  A value belonging to a particular Volvo Penta device - Power Module. Communication over the J1587
  interface.
  Data message PID 444 Battery #2 Potential (Voltage)
       Measured electrical of the isolated battery #2.
 Loadsharing
 RQSP Aver
  Value group                 Loadsharing           Related FW             3.4.0
  Resolution [units]          1 [%]
  Comm object                 10136                 Related applications   AS
  Description
  Average value calculated from all Speed Request values of controllers running in Loadsharing mode together
  (on the same CAN2 bus). See Load sharing block diagram.
 RQSP Ramp
  Value group                 Loadsharing           Related FW             3.4.0
  Resolution [units]          1 [%]
  Comm object                 10181                 Related applications   AS
  Description
  Ramped Loadsharing: RQSP Aver Value (in Loadsharing mode) or ramped Engine Values: Speed Request
  value (in Running mode). The Ramp speed is specified by setpoint Loadsharing: RQSP Ramp. See
  Loadsharing block diagram.
       Note: The Loadsharing state can be activated from Running state and if both following conditions are
       met:
                Actual Engine speed is in range specified by setpoints ClutchMinSpeed (page 139) and
                ClutchMaxSpeed (page 139)
                REM CLUTCH (PAGE 174) is active (or I/0 front panel button is pressed)
       There is loadsharing activation delay specified by setpoint Loadsharing: Clutch Del to postpone
       loadsharing regulation after transient events after engine mechanical connection to gear-box.
       Note: It is essential requirement to configure engine load information (ECU value “actual load”, physical
       analog input reading actuator position feedback or boost pressure etc.) into ENGINE TORQUE (PAGE 236)
       for loadsharing functionality.
       Note: All ID-DCU Industrial controllers working in the same loadsharing group have to be interconnected
       on CAN2 bus, controllers must have different controller addresses.
       Note: Loadsharing state - the Loadsharing: Back Up Speed value is taken into account instead of Speed
       Request (page 256) if the REQUESTED RPM (PAGE 236) indicates Sensor Fail (#####) and BACK UP
       SPEED1 (PAGE 173) is active.
 CPU Temp
  Value group                 Analog CU            Related FW               3.4.0
  Resolution [units]          1 [°C]
  Comm object                 10124                Related applications     AS, SS
  Description
  Internal Temperature measured on controller board.
 D+
  Value group                 Analog CU            Related FW               3.4.0
  Resolution [units]          1 [V]
  Comm object                 10603                Related applications     AS, SS
  Description
  Engine alternator output voltage detected at D+ controller terminal.
 Oil Press
  Value group                 Analog CU            Related FW               3.4.0
  Resolution [units]          1 [Bar]
  Comm object                 9155                 Related applications     AS, SS
  Description
 AIN CU 2
  Value group                 Analog CU            Related FW               3.4.0
  Resolution [units]          1 [-]
  Comm object                 9156                 Related applications     AS, SS
  Description
  Analog input value corresponding to analog input located directly on ID-DCU controller.
       Note: The name "Ain CU 2" is just default value which can be changed in analog input Property: Name.
 AIN CU 4
  Value group                 Analog CU           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 9158                Related applications      AS, SS
  Description
  Analog input value corresponding to analog input located directly on ID-DCU controller.
       Note: The name "Ain CU 4" is just default value which can be changed in analog input Property: Name.
 AIN CU 5
  Value group                 Analog CU           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 9159                Related applications      AS, SS
  Description
  Analog input value corresponding to analog input located directly on ID-DCU controller.
       Note: The name "Ain CU 5" is just default value which can be changed in analog input Property: Name.
 AIN CU 6
  Value group                 Analog CU           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 9160                Related applications      AS, SS
  Description
  Analog input value corresponding to analog input located directly on ID-DCU controller.
       Note: The name "Ain CU 6" is just default value which can be changed in analog input Property: Name.
 AIN CU 8
  Value group                 Analog CU           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 9162                Related applications      AS, SS
  Description
  Analog input value corresponding to analog input located directly on ID-DCU controller.
       Note: The name "Ain CU 8" is just default value which can be changed in analog input Property: Name.
 ID BOUT
  Value group                 Binary CU         Related FW             3.4.0
  Resolution [units]          [-]
  Comm object                 8239              Related applications   AS, SS
  Description
  Controller binary outputs state indication.
 LogBout 2
  Value group                 Log Bout          Related FW             3.4.0
  Resolution [units]          [-]
  Comm object                 9144              Related applications   AS, SS
  Description
  List of logical binary outputs.
 LogBout 3
  Value group                 Log Bout          Related FW             3.4.0
  Resolution [units]          [-]
  Comm object                 9145              Related applications   AS, SS
  Description
  List of logical binary outputs.
 LogBout 4
  Value group                 Log Bout          Related FW             3.4.0
  Resolution [units]          [-]
  Comm object                 9146              Related applications   AS, SS
  Description
  List of logical binary outputs.
 LogBout 5
  Value group                 Log Bout          Related FW             3.4.0
  Resolution [units]          [-]
  Comm object                 9147              Related applications   AS, SS
  Description
  List of logical binary outputs.
 LogBout 7
  Value group                 Log Bout            Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 9149                Related applications       AS, SS
  Description
  List of logical binary outputs.
 LogBout 8
  Value group                 Log Bout            Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 9150                Related applications       AS, SS
  Description
  List of logical binary outputs.
 RemoteControl
  Value group                 Log Bout            Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 10627               Related applications       AS, SS
  Description
  List of logical binary outputs, which can be closed and opened remotely, e.g. from InteliMonitor using the
  "Remote switches" tool or using Modbus communication.
 PasswordDecode
  Value group                  Info                  Related FW                3.4.0
  Resolution [units]           [-]
  Comm object                  9090                  Related applications      AS, SS
  Description
  This value contains encrypted serial number of the controller and administrator password and is intended for
  retrieving of the lost password. Send this number together with controller serial number to your distributor if
  you need to retrieve your password.
 Build date
  Value group                  Info                  Related FW                3.4.0
  Resolution [units]           [-]
  Comm object                  24211                 Related applications      AS, SS
  Description
  Date of controller fimrware creation.
 SW version
  Value group                  Info                  Related FW                3.4.0
  Resolution [units]           [-]
  Comm object                  24339                 Related applications      AS, SS
  Description
  Major and minor firmware version number. E.g. value "2,2" means version 2.2. Release version number is
  not included.
 SW Branch
  Value group                 Info                  Related FW             3.4.0
  Resolution [units]          1 [-]
  Comm object                 8707                  Related applications   AS, SS
  Description
  Firmware branch code. Contains 1 in case of standard branches.
 Mode ID
  Value group                 Info                  Related FW             3.4.0
  Resolution [units]          1 [-]
  Comm object                 9887                  Related applications   AS, SS
  Description
  This value contains actual controller mode. The controller mode is selected by Mode ID (page 103) but the
  setpoint can be overridden by REMOTE OFF (PAGE 168).
 Timer Text
  Value group                 Info                  Related FW             3.4.0
  Resolution [units]          1 [-]
  Comm object                 10040                 Related applications   AS, SS
  Description
  Code of the currently running system process timer. The text representation of each code can be obtained by
  the procedure described at the value Engine state.
 Timer Val
  Value group                 Info                  Related FW             3.4.0
  Resolution [units]          1 [s]
  Comm object                 8955                  Related applications   AS, SS
  Description
  The value contains remaining time of the currently running system process timer.
 CAN32
  Value group                 Info                  Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 8827                  Related applications       AS
  Description
  Bits of this value show "1" if the controller receives messages from the controller which has address
  corresponding with the bit position. Bit 0 represents address 17 etc. This value contains information about
  controllers with addresses 17-32.
       Note: The bit which corresponds to the own controller is always set to "1".
 Diag Code
  Value group                 Info                  Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 9654                  Related applications       AS, SS
  Description
  Displays the source (protocol) of the currently received DTC error message. Diag Code is currently used
  only for information in History. After writing to History Diag Code is reset back to ####.
  List of possible values:
        Address               Unit
        0                     broadcast
        128                   Engine ECU
        158                   Power Module
 ECU Alarms 1
  Value group                 Info                 Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 10916                Related applications       AS, SS
  Description
  States of predefined ECU alarms, which are available with Modbusreading.
       Note: Alarm linked with a specific bit is defined in ESC (Engine Specific Code) and is not user
       configurable.
 ECU Alarms 2
  Value group                 Info                 Related FW                 3.4.0
  Resolution [units]          [-]
  Comm object                 10917                Related applications       AS, SS
  Description
  States of predefined ECU alarms, which are available with Modbus reading.
       Note: Alarm linked with a specific bit is defined in ESC (Engine Specific Code) and is not user
       configurable.
 ECU Alarms 4
  Value group                 Info                    Related FW                   3.4.0
  Resolution [units]          [-]
  Comm object                 10919                   Related applications         AS, SS
  Description
  States of predefined ECU alarms, which are available with Modbus reading.
       Note: Alarm linked with a specific bit is defined in ESC (Engine Specific Code) and is not user
       configurable.
 RS485 Detected
  Value group                 Info                    Related FW                   3.4.0
  Resolution [units]          1 [-]
  Comm object                 24118                   Related applications         AS, SS
  Description
           Detecting the presence of the ID-COM module with the RS485 interface occurs only when the
           controller is initialized (when the controller is switched on or during reboot)
           Only informative data for configuration analysis (use for technical support).
Note: Not intended to be used in the PLC or history (specific data structure).
 Latitude
  Value group                 Info                    Related FW                   3.4.0
  Resolution [units]          [-]
  Comm object                 11678                   Related applications         AS, SS
  Description
  GPS coordinate received from InteliBridge-NT (IB-NT).
 GPS Speed
  Value group                 Info               Related FW               3.4.0
  Resolution [units]          0.1 [kts]
  Comm object                 12165              Related applications     AS, SS
  Description
  Speed in knots received from IB-NT (1 knot = 1.852 km/h).
 ECU State
  Value group                 Info               Related FW               3.4.0
  Resolution [units]          [-]
  Comm object                 10034              Related applications     AS, SS
  Description
  Diagnostic states of the main ECU (i.e. ECU, which has automatically connected inputs to logical
  functions).
  Indicates 4 basic "lamps":
       Yellow Warning Lamp
       Red Stop Lamp
       Wait To Start Lamp
       Malfunction Lamp
 NumSuccStarts
  Value group                 Statistics           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 8207                 Related applications      AS, SS
  Description
  Successful engine start number counter. The counter is increased by 1 even if the particular start command
  will take more than one attempt.
       Note: The counter can be readjusted / reset from InteliMonitor menu Monitor -> Set statistics.
 NumUnscStarts
  Value group                 Statistics           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 10149                Related applications      AS, SS
  Description
  Unsuccessful starts counter. The counter is incremented always when Start fail alarm is issued.
       Note: The counter can be readjusted / reset from InteliMonitor menu Monitor -> Set statistics.
 Service Time
  Value group                 Statistics           Related FW                3.4.0
  Resolution [units]          1 [-]
  Comm object                 9648                 Related applications      AS, SS
  Description
  This is maintenance countdown timer. The timer is located in setpoints group Engine protect as well as in
  Statistics values. Adjust the timer to the requested maintenance interval. It will be decremented while the
  engine is running. The alarm WrnServiceTime is issued as soon as the timer counts down to zero.
 TripCons
  Value group                 Statistics           Related FW                 3.4.0
  Resolution [units]          1 [-]
  Comm object                 9817                 Related applications       AS, SS
  Description
  Trip fuel consumption calculated by controller from FUEL CONSACT (PAGE 237).
 Memo1
  Value group                 Statistics           Related FW                 3.4.0
  Resolution [units]          1 [-]
  Comm object                 8230                 Related applications       AS, SS
  Description
  There are two Statistics registers Memo1 and Memo2. Those statistic values are based on Logical Analog
  Input Memory1 or Memory2 value in the time of Logical Binary input Memo1 Trigger or Memo2 Trigger
  rising edge. Both statistics values is possible to modify in InteliMonitor – Set Statistics command.
 MomAvgFlCon L
  Value group                 Statistics           Related FW                 3.4.0
  Resolution [units]          0.1 [/nm]
  Comm object                 11321                Related applications       AS, SS
  Description
  Momentary average fuel consumption per nautical mile. It is available, if both FUEL CONSUMP (PAGE 237) and
  BOAT SPEED (PAGE 1) are configured.
 Following are examples of transfer characteristics 0 – 100 % to 4 – 20 mA. The first case is transfer
 characteristics -25 – 100 % to 0 – 20 mA, it contains the needed conversion to 4 – 20 mA.
6 back to Appendix
   Description
   Inteli AIN8 module is extension module equipped with analog inputs and impulse input.
   The module can be used for ID-DCU, InteliMains-NT, InteliGen-NT and InteliSys-NT controllers.
 Available inputs/outputs
 Analog inputs
     8 channels
     Can be configured as
          Resistor three wire input
          Current input
          Voltage input
 Impulse input
     1 channel
     Can be configured as
          Impulse
          Impulse/time
          RPM
 All inputs can be configured to any logical function or protection.
 It is possible to connect up to 10 modules to the InteliGen-NT, InteliSys-NT or InteliMains-NT controllers or up
 to 4 modules to the ID-DCU.
 Inteli AIN8 module is connected to controller CAN1 bus.
Supported sensors
                                                      Sensors
                                                    User curves
                                                   PT100 [°C] (fix)
                                                  PT1000 [°C] (fix)
                                                   NI100 [°C] (fix)
                                                  NI1000 [°C] (fix)
                                                   PT100 [°F] (fix)
                                                  PT1000 [°F] (fix)
                                                   NI100 [°F] (fix)
                                                  NI1000 [°F] (fix)
                                                0-250ohm (fix linear)
                                                0-2400ohm (fix linear)
                                                0-10k ohm (fix linear)
                                                   +-1V (fix linear)
Dimensions
  Programming Firmware
  Firmware upgrade is via AT-link (TTL). For programming it is necessary to close jumper TEST.
  For programming use FlashProg PC tool version 4.2 or higher.
After selection you configure input - in card “I/O”, group “Impulse input”
 RPM
 In this case you can set name of this input and set the number of gear teeth.
 Value of RPM is placed in value group: “RPM & Imp/time“ 
 Example
 We have electric meter, which gives 1000 pulses/ 1kWh.
 Value, which is saved to statistic will be calculate to three decimal places and will be in MWh value. In case
 electricity meter is used, the valid pulse from eletricity meter is defined by norm DIN 43864 and norm IEC
 62053-31 – for equipment class A. In these norms the valid pulses are defined with these parameters: minimal
 Ton≥30ms, min Toff≥30ms.
 In case flow meters you can use Ton≥10ms, min Toff≥10ms, or you can use option “Custom meter” where you
 can define any Ton and Toff.
 Value is placed in value groupe: “Statistic“ This type of impulse input is designed for measurement of total
 electricity consumption – in this case.
 Counter value for counting of value from input is with range 4 294 967 295.
 So, 100 pulses=0.01kWh => range is 4 294 967 2.95 kWh.
 Output value is in MWh, so range is 4 294 9.67 295 MWh. [kWh ->MWh]
 If counter value achieves this number (4 294 9.67 295 MWh), then it is cleared and count from 0 value again.
 Impulse/time
 This option counts pulses for any period and value says, how many pulses came in last defined period.
 Impulse+Impulse/time
 In this option you can choose the combination of Impuls and Impuls/Time inputs.
 There are two value – total number of “pulses” and number of “pulses” per last period.
 Description of both you can see higher.
 Wiring
 The following diagrams show the correct connection of sensors.
Terminator
 Measuring resistance
     3 – wire measurement
 Measuring current
     Active sensor
Ranges: ±1 V, 0 – 2,5 V, 0 – 5 V, 0 – 10 V
 Impulse input
     1 channel
     Can be configured as
          Impulse
          Impulse/time
          RPM
 All inputs can be configured to any logical function or protection.
 It is possible to connect up to 10 modules to the InteliGen-NT, InteliSys-NT or InteliMains-NT controllers or up
 to 4 modules to the ID-DCU.
 Inteli AIN8 module is connected to controller CAN1 bus.
Technical data
  Impulse input
                         Level of signal                               2 Vpk-pk ÷ 70 Vpk-pk
  *RPM
                         Frequency range                               4 Hz ÷ 10 kHz
                                  CAN bus is galvanic separated from the measurement and power supply.
   Galvanic separation            All analog inputs are galvanic separated from power supply.
                                  Analog inputs are not galvanic separated between channels
   Power supply                                                    8 to 36 V DC
   Protection                                                      IP20
   Current consumption                                             35 mA at 24 V ÷ 100 mA at 8 V
   Storage temperature                                             - 40 °C to + 80 °C
   Operating temperature                                           - 30 °C to + 70 °C
   Heat radiation                                                  3W
Inteli AIN8TC unit can be mounted on DIN rail (35 mm). All dimensions are in mm.
Supported sensors
                                                         Sensors
                                                  Thermocpl J [°C] (fix)
                                                  Thermocpl K [°C] (fix)
                                                  Thermocpl L [°C] (fix)
                                                  Thermocpl J [°F] (fix)
                                                  Thermocpl K [°F] (fix)
                                                  Thermocpl L [°F] (fix)
                                                Thermocpl (nc) J [°C] (fix)
                                                Thermocpl (nc) K [°C] (fix)
                                                Thermocpl (nc) L [°C] (fix)
                                                Thermocpl (nc) J [°F] (fix)
                                                Thermocpl (nc) K [°F] (fix)
                                                Thermocpl (nc) L [°F] (fix)
 Note: “nc” means“ not cold junction compensation (by external sensor).In this case is used internal temperature
 sensor on the PCB
Terminals
  Programming firmware
  Firmware is upgraded via AT-link (TTL). For programming it is necessary to close jumper TEST.
  For programming FlashProg PC tool version 4.2 or higher must be used.
  LED indication
  LED at power connector – status LED
Wiring
Technical data
  Power supply                                                8 to 36 V DC
  Protection                                                  IP20
  Current consumption                                         35 mA at 24 V ÷ 100 mA at 8 V
  Storage temperature                                         - 40 °C to + 80 °C
  Operating temperature                                       - 30 °C to + 70 °C
  Heat radiation                                              2W
  Description
  Inteli IO8/8 module is an extension module equipped with binary inputs, binary outputs and analog outputs.
  The module can be used for ID-DCU, InteliMains-NT, InteliGen-NT and InteliSys-NT controllers.
  “Inteli IO8/8” is the name of the module, but it is possible to configure the module (by internal switch) to two
  configurations:
      Inteli IO8/8 (8 binary inputs, 8 binary outputs and 2 analog outputs)
      Inteli IO16/0 (16 binary inputs, 0 binary outputs and 2 analog outputs)
  This module is compatible with MTU ECU-7 at communication speed 125 kbps when uploaded with firmware
  1.1.0 and higher.
  The detection of communication speed is indicated by fast flashing of status LED. Once the speed is detected
  the module remains set for the speed even when the communication is lost. Renewal of communication speed
  detection is done by reset of the module.
  Available inputs/outputs
  Binary inputs
      8 channels
      Can be configured as:
           Pull up
           Pull down
  All 8 inputs are configured to one type together.
 “Output state check” function evaluates in real time the state of binary outputs and adjusted (required) state.
 In case of failure (different state of required state and real state) history record and alarm are issued (type of the
 alarm is set by “Protection upon module failure” - (no alarm/warning/SD)).
 This function is designed for short-circuit or other failure, which causes change of set state of binary output.
 Analog outputs
     2 channels
     Can be configured as:
          Voltage 0-10V
          Current 0-20mA
          PWM (level 5V, with adjustable frequency from 200Hz to 2400Hz, with step 1Hz)
 All inputs/outputs can be configured to any logical function or protection.
 It is possible to connect up to 12 modules (in configuration 8inputs/8outputs) to the InteliGen-NT, InteliSys-NT
 or InteliMains-NT controllers or up to 4 modules to the ID-DCU.
 Inteli IO8/8 module is connected to controller CAN1 bus.
Dimensions
  Programming Firmware
  Firmware upgrade is via AT-link (TTL). For programming is necessary to close jumper TEST.
  For programming FlashProg PC tool version 4.2 or higher must be used.
  LED indication
  Binary input
  Each binary input has LED which indicates input signal. LED is shining when input signal is set, and LED is
  dark while input signal has other state.
  Binary output
  Each binary output has LED which indicates output signal. Binary output LED is shining when binary output is
  set.
 There are two options of wiring. On left side you can see case when binary input is connected between pins BI1
 and COM (COM is connected internally to the GND).
 On right side is case of wiring between pins BI1 and GND. Both ways are correct.
     Pull down
 Two options of wiring
 There are two options of wiring. On left side you can see case when binary input is connected between pins BI1
 and COM (COM is connected internally to the +Ucc).
 On right side is case of wiring between pins BI1 and +Ucc. Both ways are correct.
     IMPORTANT: Do not connect COM pin to power (GND or Ucc). Otherwise the module will be
     damaged.
 Binary outputs
     High side
Analog outputs
 Terminator for analog output has special analog ground (AGND), which must not be connected to the GND.
 Limit of analog ground (AGND) is 100mA.
Technical data
  Binary inputs
  Input resistance                                             4400 Ω
  Input range                                                  0 to 36V DC
  Switching voltage level for open contact indication          0 to 2 V
  Max voltage level for close contact indication               6 to 36 V
                                 CAN bus is galvanic separated from the measurement and power supply. All
  Galvanic separation
                                 Inputs/outputs are not galvanic separated from power supply
  Power supply                                            8 to 36 V DC
  Protection                                              IP20
  Current consumption                                     35 mA at 24V ÷ 100 mA at 8 V
  Storage temperature                                     - 40 °C to + 80 °C
  Operating temperature                                   - 30 °C to + 70 °C
  Heat radiation                                          4W
 The product is fully supported in fw IGS-NT 3.0 or higher and in IGS-NT-branches based on this fw.
 6 back to Extensional modules
  Description
  IS-BIN16/8 is an extension module with 16 binary inputs (galvanic separated) and 8 binary output (galvanic
  separated), 2 pulse inputs (frequency measurement or pulse counting). All I/O can be configured to any logical
  function or protection. It is possible to connect up to 6 IS-BIN16/8 external units to one controller. External
  modules IS-BIN16/8 is connected to controller CAN1 bus. To operate external modules:
      Connect all external modules to CAN1 bus line
      On each module adjust I/O CAN1 address in the range of 1 to 7 for IS-BIN16/8 output, 1,3,5,7,9,11,13 for IS-
      BIN18/8 inputs
      In case of use generic module in configuration you can set CAN address from 1 – 12
      In case of set 0 CAN address - inputs/ outputs are deactivated
      Input output address is displayed on the front panel LCD’s
      Use PC configuration tool to configure controller according external modules setting
  IS-BIN16/8 module has two separate CAN1 addresses for binary inputs Group 1, Group 2 and binary output
  Group (total three addresses). The CAN1 address for BI Group 1 and for BO Group 2 can be adjusted on the IS-
  BIN16/8. The address for BI Group 2 is set automatically to the address following BI Group 1.
  Note: CAN address 0 disables corresponding CAN message (Group data are not send).
                                                                                 CAN 1 Address
                                                                    Inputs                         Output
                         1. IS-BIN16/8                                 1                              1
                         2. IS-BIN16/8                                 3                              2
                         3. IS-BIN16/8                                 5                              3
                         4. IS-BIN16/8                                 7                              4
 SW version check
 Let suppose IS-AIN8 of SW version 1.4. Shortly press address button. Following sequence appears on the
 display: number “1”, one second pause, number “4”, two second pause, number “1”, one second pause, number
 “4”, two second pause and finally IS-AIN8 actual address.
 Error message (e.g. SD BOUT2) appears on Controller screen when Binary input or output Address x is
 configured but corresponding unit is not recognized (no message is received from CAN bus). Check IS
 configuration and corresponding external IS-AIN, IS-BIN unit address setting.
LED indication
                                   Tx                                                  Rx
              Dark                              Blink        Light           Dark            Blink         Light
  Any data are                                                       Any data are
                                   Data are transmitted                                Data are received
  transmitted on the                                                 received on the
                                   on the CAN1 line                                    on the CAN1 line
  CAN1 line                                                          CAN1 line
                                                   Table 8.2 Tx / Rx LED status
Wiring
Image 8.5 CAN bus line has to be terminated by 120 ohm resistors on the both ends.
 Note: CAN bus line has to be terminated by 120 ohm resistors on the both ends.
 For longer distances is recommended to connect CAN COM terminals between all controllers and cable
 shielding to the ground in one point!
 Recommended CAN bus data cables see in Chapter Technical data.
 External units can be connected on the CAN bus line in any order, but line arrangement (no tails no star) is
 necessary-
 Recommended CAN bus data cables see in Chapter Technical data.
       Binary inputs Common terminal is connected to          Binary inputs common terminal is connected to
    positive supply terminal, Binary inputs contacts are    negative supply terminal, Binary inputs contacts are
             closed to negative supply terminals.                  closed to positive supply terminals.
  Input voltage range for opened contact is from 8 VDC to Power supply VDC. Input voltage range for closed
  contact is from 0 to 2 VDC. Voltage level is defined between Binary input and Binary input COM terminal and
  does not depend on “positive” or “negative” connection.
  Impulse inputs do not work with IGS-NT controller.
  Binary output
  The Common terminal can be connected to positive or negative pole (HW3.0 only) – see following drawing.
  Binary outputs are galvanic separated from IS-BIN16/8 power supply (have a look at technical data). The
  maximum load values are 0.5 A / 36V for one output.
Binary output common terminal is connected to negative         Binary output common terminal is connected to
  supply terminal, Binary output contacts are closed to     positive supply terminal, Binary output contacts are
                  positive supply terminals.                        closed to negative supply terminals.
 For more extension units use separate fusing according to the table above.
 Controller power supply should never be connected to starter terminals.
Technical data
   Relays outputs (galvanic separated) only HW 3.0 (non galvanic separated) HW 2.1
   Number of output                                            8
   Maximum current                                             0.5A DC
   Maximum switching voltage                                   36 VDC
   Power supply                                     8 to 36 V DC
   Protection front panel                           IP20
   Current consumption                              250 mA** at 24 V
   Humidity                                         95% without condensation
   Storage temperature                              - 40 °C to + 80 °C
   Operating temperature                            - 30 °C to + 70 °C
   Heat radiation                                   2W
Standard conformity
Number of output                                           8
Low Voltage Directive                                      EN 61010-1:95 +A1:97
                                                           EN 50081-1:94, EN 50081-2:96
Electromagnetic Compatibility
                                                           EN 50082-1:99, EN 50082-2:97
*RPM1, RPM2 are available in IS-CU only          **During powering up current can be up to 1.5A
  6 back to Extensional modules
  Description
  Inteli AIO9/1 module is extension module equipped with analog inputs and outputs – designed for DC
  measurement.
  The module can be used for ID-DCU, InteliMains-NT, InteliGen-NT and InteliSys-NT controllers.
  This module is compatible with MTU ECU-7 at communication speed 125 kbps when uploaded with firmware
  1.2.0 and higher.
  The detection of communication speed is indicated by fast flashing of status LED. Once the speed is detected
  the module remains set for the speed even when the communication is lost. Renewal of communication speed
  detection is done by reset of the module.
  Available inputs/outputs
  Analog inputs
      4 channels AIN1 – AIN4 can be configured as:
           Sensor ±65V (it is determinated for measurement of battery voltage)
      4 channels AIN5 – AIN8 can be configured as:
           Thermocouples – type J,K or L (in °C or °F)
           Sensor ±75mV DC – (for connecting current shunts)
      1 channel AIN9 can be configured as:
           RTD (Pt1000, Ni1000)
           Common resistance 0-2400Ω
Supported sensors
                                                        Sensors
                                                       User curves
                                                    PT1000 [°C] (fix)
                                                     NI1000 [°C] (fix)
                                                   0-2400Ω (fix linear)
                                                  ± 65 V DC (fix linear)
                                                   +-75mV (fix linear)
                                                  Thermocpl J [°C] (fix)
                                                  Thermocpl K [°C] (fix)
                                                  Thermocpl L [°C] (fix)
                                                Thermocpl (nc) J [°C] (fix)
                                                Thermocpl (nc) K [°C] (fix)
                                                Thermocpl (nc) L [°C] (fix)
                                                Thermocpl (nc) J [°F] (fix)
                                                Thermocpl (nc) K [°F] (fix)
                                                Thermocpl (nc) L [°F] (fix)
Terminals
  LED indication
  LED at power connector – status LED
  Wiring
  The following diagrams show the correct connection of sensors.
Technical data
  Analog output
  I 0-20mA /500Rmax. ± 1 % of actual value + ± 200 uA
  U 0-10V ± 0.5 % of actual value + ± 50 mV
  PWM – 5 V, 200 Hz-2.4kHz 15 mA max.
  Galvanic separated from power supply
Galvanic separation CAN bus is galvanic separated from the measurement and power supply
8.2.6 IS-AIN8
  Description
  IS-AIN8 is input extension module equipped with 8 analog inputs. The module can be used for ID, IGS-NT
  controller. IS-AIN8 can be configured to:
      Resistor two wire input
      Resistor three wire input
      Current input
      Thermocouple input
      Voltage input
  All inputs can be configured to any logical function or protection. It is possible to connect up to 10 IS-AIN8 (with
  IGS-NT) or up to 4 (with ID) external units to one controller. IS-AIN8 is connected to controller CAN1 bus.
  This module is compatible with MTU ECU-7 at communication speed 125 kbps when uploaded with firmware
  1.2.0 and higher.
Dimensions
                                                                          CAN 1 Address
                      1. IS-AIN8                                                 1
                      2. IS-AIN8                                                 2
                      3. IS-AIN8                                                 3
                      4. IS-AIN8                                                 4
                      5. IS-AIN8                                                 5
                      6. IS-AIN8                                                 6
 SW version check
 Let suppose IS-AIN8 of SW version 1.4. Shortly press address button. Following sequence appears on the
 display: number “1”, one second pause, number “4”, two second pause, number “1”, one second pause, number
 “4”, two second pause and finally IS-AIN8 actual address. Error message (e.g. SD BOUT2) appears on
 Controller screen when Binary input or output Address x is configured but corresponding unit is not recognized
 (no message is received from CAN bus). Check IS configuration and corresponding external IS-AIN8, IS-
 BIN8/16 unit address setting.
LED indication
                                        Tx                                                      Rx
              Lighting                                 Blink                     Lighting                  Blink
                                                                             Any data are
    Any data are transmitted           Data are transmitted on the CAN1                              Data are received
                                                                            received on the
        on the CAN1 line                                line                                         on the CAN1 line
                                                                                CAN1 line
                                                  Table 8.6 Tx/Rx LED status
Wiring
Select sensor characteristic from the list or define user sensor characteristic in PC configuration tool.
D terminal is shielding
                                                  Voltage input
                                                  Range 0 to + 2500 mV.
                                                  Voltage range is 0 to ±1000 mV.
                                                  D terminal is shielding
 Note: If the thermocouples are connected to IS-AIN8, appropriate jumpers must be removed (see rear sticker).
 (jumpers are placed under the cover)
       Example 1 shows the correct temperature measurement. The 3rd metal (the cable between IS-AIN8 and
       thermocouple) is connected in cold bath which temperature is 0°C. This is very difficult to provide in real
       application.
       Example 2 shows the correct temperature measurement. The 3rd metal (the cable between IS-AIN8 and
       thermocouple) is connected in ambient environment which temperature is not 0°C, but T1°C. Resultant
       temperature is correct, because is compensated by internal IS-AIN8 temperature sensor. The temperature
       of IS-AIN8 and junction is the same T-T1+T1 (reduced and compensated by T1).
       Example 3 shows the incorrect temperature measurement. The 3rd metal (the cable between IS-AIN8 and
       thermocouple) is connected in ambient environment which temperature is not 0°C, but T1°C. Resultant
       temperature is T-T1 (reduced by T1). Internal IS-AIN8 compensation should not by used because measures
       T2 temperature, not T1!
       Example 4 shows the correct temperature measurement. The 3rd metal (the cable between IS-AIN8 and
       thermocouple) is connected in ambient environment which temperature is not 0°C, but T1°C. Resultant
       temperature is correct, because is compensated by external temperature sensor, T+T1 (reduced and
       compensated by T1).
 Note: LAI (logical analog input) Cold Temp 1 compensates every of 8 thermocouples inputs of IS-AIN8 on
 address 1IS-AIN8 on address 2 – 10 is not compensated by this LAI Cold Temp1.
          Any of non thermocouple configured input is not compensated anyway
          Any of non thermocouple input with sensor adjusted as compensated is not compensated by external
          compensation (IS-AIN8 compensates it itself)
          IS-AIN8 on address 2 – 10 is not compensated by this LAI Cold Temp1.
 LAI Cold Temp 2 compensates every of 8 thermocouples inputs of IS-AIN8 on address 2, etc.
 Up to 32 (Cold Temp 1-4 times 8 analog input of IS-AIN8) may by compensated by external sensor.
 Even only one external sensor may be configured for more than one LAI Cold Temp.
Technical data
   Standard conformity
   Low Voltage Directive                                EN 61010-1:95 +A1:97
                                                        EN 50081-1:94, EN 50081-2:96
   Electromagnetic Compatibility
                                                        EN 50082-1:99, EN 50082-2:97
8.2.7 IS-AIN8TC
  Description
  IS-AIN8 is input extension module equipped with 8 analog inputs dedicated for thermocouple sensors only. The
  module can be used for ID, IGS-NT controller. IS-AIN8TC can be configured to:
Dimensions
Connectors
                                                                                 CAN11 Address
                         1. IS-AIN8TC                                                  1
                         2. IS-AIN8TC                                                  2
                         3. IS-AIN8TC                                                  3
                         4. IS-AIN8TC                                                  4
                         5. IS-AIN8TC                                                  5
                         6. IS-AIN8TC                                                  6
                         7. IS-AIN8TC                                                  7
                         8. IS-AIN8TC                                                  8
                         9. IS-AIN8TC                                                  9
                         10. IS-AIN8TC                                                 0
                               Table 8.7 Table of recommended CAN1 address setting
 SW version check
 Shortly press address button. Following sequence appears on the display: number “1”, one second pause,
 number “4”, two second pause, number “1”, one second pause, number “4”, two second pause and finally IS-
 AIN8TC actual address.
 Error message (e.g. SD BOUT2) appears on Controller screen when Binary input or output Address x is
 configured but corresponding unit is not recognized (no message is received from CAN bus). Check IS
 configuration and corresponding external IS-AIN8TC, IS-BIN8/16 unit address setting.
LED indication
                                  Tx                                                    Rx
               Dark                             Blink                     Dark                          Blink
  Any data are transmitted          Data are transmitted on    Any data are received on      Data are received on
  on the CAN1 line                  the CAN1 line              the CAN1 line                 the CAN1 line
Wiring
 Note: CAN bus line has to be terminated by 120 ohm resistors on the both ends.
 For longer distances is recommended to connect CAN COM terminals between all controllers and cable
 shielding to the ground in one point!
 External units can be connected on the CAN bus line in any order, but line arrangement (no tails no star) is
 necessary.
 Recommended CAN bus data cables see in Chapter Technical data.
 IG-MU and IG-IB units are connected to CONTROLLER CAN2 bus.
Select sensor characteristic from the list or define user sensor characteristic in PC configuration tool.
Technical data
   Power supply                                                 8 to 36 V DC
   Protection                                                   IP20
   Current consumption                                          35 mA at 24 V ÷ 100 mA at 8 V
   Storage temperature                                          - 40 °C to + 80 °C
   Operating temperature                                        - 30 °C to + 70 °C
   Heat radiation                                               2W
8.2.8 IGS-PTM
  Description
  IGS-PTM is modification of standard IG-IOM module with four analog inputs, which can be configured for range:
Dimensions
Terminals
  Address configuration
  If IGS-NT controller type is selected (by IGS jumper), address of IGS-PTM could be modified via jumpers
  labeled ADR1 and ADR2.
      ADR1           ADR2            BIN module              BOUT module            AOUT module   AIN module
      Open           Open                   1                         1                       1       1
      Close          Open                   2                         2                       2       2
      Open           Close                  3                         3                       3       3
      Close          Close                  4                         4                       4       4
 Programming firmware
 Firmware upgrade is via AT-link (TTL). For programming is necessary to close jumper BOOT. RESET jumper is
 used to reset the device. Close jumper to reset the device. For programming is used FlashProg PC tool.
 LED indication
 Binary inputs
 Each binary input has LED which indicates input signal. LED is shining when input signal is set, and LED is
 dark while input signal has other state.
 Binary output
 Binary output LED shining when binary output is set.
Power
Note: It is not necessary to connect analog inputs COM terminal to negative power supply.
 Note: Maximum resistance of two leads (from IGS-PTM to sensor and back) can be 20W. Otherwise the
 compensation fails. Unused analog inputs must be shorted at the IGS-PTM.
Technical data
  Binary inputs
  Input resistance                                           4700 Ω
  Input range                                                0 to 36V DC
  Type                                                       Pull Up
  Switching voltage level for open contact indication        0 to 2 V
  Max voltage level for open contact indication              8 to 36 V
  Power supply                                                 8 to 36 V DC
  Protection                                                   IP20
  Current consumption                                          100 mA at 24V ÷ 500 mA
  Storage temperature                                          - 40 °C to + 8 0°C
  Operating temperature                                        - 30 °C to + 80 °C
  Heat radiation                                               8W
  For more information about IB-NT, please see InternetBridge-NT Global Guide
  Note: Connect ID DCU HW 2.0 and newer + ID-COM with RS485 connected to IB-NT over RS485 works fine.
  But: only one couple of balancing resistors has to be added on the whole RS485 line, and setpoint in ID-DCU
  CommSet called RS485 TermCSpd (page 114) has to be set to 57600 bps.
  Description
  I-AOUT8 is an extension unit with 8 analog outputs. Each analog output can be switched to
      0 to 20 mA DC
      0 to 10 V DC
      PWM (Pulse With Modulation on 1.2 kHz)
  I-AOUT8 module is connected on IGS-NT or ID CAN1 (peripheral) bus. The corresponding module Address 1 to
  4 (default 1) must be set on module (by Adr.1 and Adr.2 jumpers) and in controller configuration. Communication
  fail is indicated in controller Alarm list and by binary output. Use DriveConfig PC tool for controller configuration.
  It is possible to connect up to four I-AOUT8 units to one controller. CAN1 terminating 120Ω resistor jumper is
  connected as default. AGND terminals are on the same potential.
  General Description
  I-AOUT8 is an extension unit with 8 Analog outputs. Each analog output can be switched by jumper for.
      0 to 20 mA
      0 to 10 VDC
      PWM (Pulse With Modulation on 1,2 kHz)
  I-AOUT8 modules is connected on CAN 1 (peripheral) bus. The corresponding module Address 1 to 4 (default 1)
  must be set on module (by Adr.1 and Adr.2 jumpers) and in controller configuration. Communication fail is
  indicated in controller Alarm list and by binary output. Use DriveConfig PC tool for controller configuration.
  It is possible to connect up to four I-AOUT8 units to one controller.
  I-AOUT8 unit can be mounted on DIN rail (35 mm).
  CAN 1 terminating 120 Ω resistor jumper is connected in default. AGND terminals are on the same potential.
Connectors
                           CAN Address                                       A1                          A2
                                   1                                         Open                       Open
                                   2                                     Close                          Open
                                   3                                         Open                       Close
                                   4                                     Close                          Close
                                                 Table 8.13 Setting CAN address
  Output mode
  Follow the p – I – I – U symbols on the module sticker. There are two equivalent positions for current output.
                                                                                            PWM
                                                          p
                                                                                    Pulse-Width-Modulation
l 0 to 20 mA DC
U 0 to 10 V DC
  Programming firmware
  Firmware upgrade is via AT-link (TTL). For programming it is necessary to close jumper BOOT. RESET jumper
  is used to reset the device. Close jumper to reset the device. For programming is used FlashProg PC tool.
  CAN1 termination
  I-AOUT8 has own CAN terminating resistor (120 ohm). Close jumper CAN-R to connect terminating resistor to
  CAN bus, open jumper CAN-R disconnecting terminating resistor.
                                                                                                              PWM
          PWM output                                                                                        output
                                                                                                            1200 Hz
                                                                                                            Current
    Current output 0 to 20                                                                                 output 0 to
            mA DC                                                                                          20 mA DC
                                                                                                            Current
    Current output 0 to 20                                                                                 output 0 to
            mA DC                                                                                          20 mA DC
                                                                                                            Voltage
  Voltage output 0 to 10 V
                                                                                                           output 0 to
               DC
                                                                                                            10 V DC
Technical data
  Power supply                                                      8 to 36 V DC
  Analog output refreshment                                         320 ms
  Current consumption                                               max 300 mA (100 mA at 24 V)
  RS232 interface                                                   TTL, firmware upgrade via AT-link.
  Storage temperature                                               - 40 °C to + 80 °C
  Operating temperature                                             - 30 °C to + 70 °C
  Heat radiation                                                    2.5 W
  Description
  InteliDrive Communication interface for proprietary and/or remote communication. The CAN1 line is used for
  J1939 (ECU) bus connection or extension modules. The CAN2 line is used for inter-controller communication
  and remote displays. There are 2 variants of the ID-COM module that differ in the interface in the middle of the
  module. The standard version includes the RS485 interface for Modbus connection or remote display
  connection. The special variant then offers the J1708/J1587 for a redundant communication link, especially in
  conjunction with Volvo Penta engines. ID-COM is mounted directly to ID-DCU box. Heat radiation of this
  module is 2 W.
Dimensions
 RS485 termination
 When point-to-point is connected (eg with display), keep both Bias and termination resistors closed - default
 jumper settings.
LED indication
  LED                        Description
  LED1, LED2                 Blink when data are transmitted / received on the CAN2 line
  LED3, LED4                 Blink when data are transmitted / received on the RS485 or J1708 line
Technical data
  Binary inputs
  Pull Up
  Principle of internal connection is showed on picture below.
  The bulb presents internal state of binary input.
  In case of connection terminal “BIN” with terminal “COM” (GND) then the internal state is logical 1.
  In case of connection +Ucc polarity to the “BIN” terminal is internal state logical 0.
 Binary outputs
 High side switch - HSS
 Principle of internal connection is showed on picture below.
 High side switch connection is for case, where load is permanently connected to the ground (GND).
 By activating of Binary output (Bout=1) is closed switch which causes connection of load to the VHS (Voltage
 High side) and +Ucc.