0% found this document useful (0 votes)
352 views4 pages

Catalogue LBS Entec

This document provides information on pole top SF6 gas insulated load break switches for power distribution systems up to 36kV. The switches use SF6 gas as an insulating and arc quenching medium to ensure positive breaking of currents. They have a spring toggle mechanism for quick close and open operation and can be operated manually or remotely. The switches have stainless steel enclosures, polymer or porcelain bushings, and microprocessor-based controllers for monitoring, metering and remote communication. Ratings are provided for voltages up to 36kV, currents up to 630A, and withstand levels.

Uploaded by

Kien Tran Trung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
352 views4 pages

Catalogue LBS Entec

This document provides information on pole top SF6 gas insulated load break switches for power distribution systems up to 36kV. The switches use SF6 gas as an insulating and arc quenching medium to ensure positive breaking of currents. They have a spring toggle mechanism for quick close and open operation and can be operated manually or remotely. The switches have stainless steel enclosures, polymer or porcelain bushings, and microprocessor-based controllers for monitoring, metering and remote communication. Ratings are provided for voltages up to 36kV, currents up to 630A, and withstand levels.

Uploaded by

Kien Tran Trung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ENhanced www.entecene.co.

kr
TEChnology

Pole Top SF6 Gas Insulated


Load Break Switch
for Power Distribution System thru 15.5kV, 25.8kV & 36kV

V. 3.0
Pole Top SF6 Gas Insulated Load Break Switch
for Power Distribution System thru 15.5kV, 25.8kV & 36kV
Pole Top SF6 Gas Insulated Load Break Switches are designed to meet growing
requirements for reliability of power distribution. Switches filled with SF6 gas as the
insulating and arc quenching medium with puffer principle in making and breaking
ensure the positive breaking of small inductive, mainly active load current, cable charging
current, magnetizing current and etc. They are manufactured under a quality system
conforming to ISO 9001.

Manual and motor operation


Features The basic mechanism is operator independent quick close and quick open spring toggle mechanism.
The switch can be operated manually or it can be operated with an integrated motor drive for remote
and/or local control. The manual operating handle is free to operate regardless of the position of the
motor driven mechanism.
Stainless steel enclosure and safety devices
The switch enclosure is made of stainless steel plate (STS304L) and filled with SF6 gas. The completely
sealed enclosure provides maintenance free operation even in severe weather conditions. It is designed
to guarantee the safety even at the maximum fault capacity.
Polymer or porcelain bushing with silicone rubber boots
The switch can be provided with hydrophobic cycloaliphatic epoxy resin(HCEP), epoxy bushing with
silicone rubber boots or porcelain bushing. The high voltage terminal is provided with the NEMA
(or clamp stud) terminal or the molded cone type lead which has high dielectric strength even under
heavily polluted conditions.
Microprocessor based controller
Microprocessor based control cubicle for feeder automation is designed for outdoor pole mounting
on a separate external panel and is normally mounted low on the pole for ease of access. The basic
control cubicle is provided with detection of phase and earth faults from current sensing elements
and checks the live and dead line status from the voltage sensing element. The details of the fault
and event log can be stored and transmitted to the SCADA or remote control unit through modem.
Pole Top SF6 Gas Insulated Load
Break Switch

EARTH CABLE

CABLE BAND
CONTROL CABLE

CONTROL BOX

Metering
Voltage & current
Measures kW and kWh, power factor
Demand watts & VARs and frequency
Load profile data & ocillogram
Monitoring & Recording
Setting, metering and data recording
Counters Fault waveforms
Remote communication(ETMFC101-N1)
ETSWC101 Ports: RS232, RS485, RJ45 (TCP/IP)
Protocols: DNP3.0, MODBUS, IEC60870-5-101/104
ETMFC101-N1 Built-in RTU

Rated voltage (kV) 15.5kV 25.8kV 36kV


Ratings
Rated current (A) 630 630 630
Frequency (Hz) 50 / 60 50 / 60 50 / 60
Short-time withstand current (kA) / 1s 16 12.5 / 16 12.5
Short-circuit making current (kA) 41.6 32.5 / 41.6 32.5
Cable charging breaking current (A) 17 25 20
Power frequency withstand voltage(kA) 50 60 70
Lightning impulse withstand voltage(kA) 110 150 170
Insulation media SF6 gas
Operating mechanism Spring toggle
Arc extinguishing method Puffer
Control and operation function RTU built-in or Separate digital control
Rated voltage 110/220V(Option)
Power supply DC 24V
Permeable voltage range 85~110%
Control
AC power frequency
2,000V 1min
withstand voltage

Basic Impulse Level 6kV


Enclosure Stainless steel (STS304L)
15.5kV SF6 Gas Insulated Load Break Switch
Construction 0)6,4-47+316/
6)5-84)<- ,M^QKM
 0)6/-:




L
kg

78-6
.
.
20
Weight
Date No.
Serial
kA(rms)

Current
Making

47+3
6 kV Rated
A
Hz


Voltage
Rated Current y


Rated Frequenc
Rated

;-)416/


+766-+<7:

!
76 7..

0)6,4- 16,1+)<7: 4-/ 8ZM[[]ZM


4WKSQVO,M^QKM

16,1+)<7: +7=6<-:


76 7..






8ZM[[]ZM
:MTQMN,M^QKM
/);.QTTQVO>IT^M;.

25.8kV SF6 Gas Insulated Load Break Switch

6IUMXTI\M
0IVLTM4WKSQVO
 ,M^QKM
0IVOMZ

185L
175kg. .
200
.:--
60Hz
GAS

47+3
SF6


25.8kV
630A

 
0IVLTM
4MO
-IZ\P\MZUQVIT
1VLQKI\WZ

+W]V\MZ
8ZM[[]ZM4WKSQVO,M^QKM
1VLQKI\WZ


) :

!

*  3>
;
)


4*;
+ <


8ZM[[]ZM
:MTQMN,M^QKM
/);.QTTQVO>IT^M;.

36kV SF6 Gas Insulated Load Break Switch

-):<0<-:516)4
 0)6,4-47+316/
 ,M^QKM 0)6/-:

 4
SO
 .:--

0b

S>
;./);
47+3



)

76 7..
0)6,4-
87;1<17616,1+)<7: 6)5-84)<-

8ZM[[]ZM4WKSQVO,M^QKM +7=6<-:

76

) :
!



* ;
!

+ <

8ZM[[]ZM
:MTQMN,M^QKM
/);.QTTQVO>IT^M;.

* Note. Product structure and arrangement shall be modified without notice. 201705

225-38 Choirubaekro, Bongdam-Eup, Hwaseong-City, Gyunggi-Do, Republic of Korea


Post code : 445-893
TEL: +82-31-299-8400 FAX : +82-31-299-8401/ 2
http://www.entecene.co.kr E-mail : entec@entecene.co.kr

You might also like