0% found this document useful (0 votes)
77 views4 pages

Esm 2 Ts

The document describes a thermocouple transmitter model M2TS that accepts direct input from a thermocouple and provides a standard process signal. It offers 5-segment linearization, burnout detection, and high-accuracy cold junction compensation. The transmitter can be configured with various thermocouple types, output signals, power inputs, response times, and approval standards. Specifications include accuracy of ±0.4% of span, cold junction compensation error of ±0.5°C, and temperature coefficient of ±0.015%/°C.

Uploaded by

ponidi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views4 pages

Esm 2 Ts

The document describes a thermocouple transmitter model M2TS that accepts direct input from a thermocouple and provides a standard process signal. It offers 5-segment linearization, burnout detection, and high-accuracy cold junction compensation. The transmitter can be configured with various thermocouple types, output signals, power inputs, response times, and approval standards. Specifications include accuracy of ±0.4% of span, cold junction compensation error of ±0.5°C, and temperature coefficient of ±0.015%/°C.

Uploaded by

ponidi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MODEL: M2TS

Super-mini Signal Conditioners Mini-M Series 8: S (Usable range -50 to +1760°C, -58 to +3200°F)
N: N (Usable range -270 to +1300°C, -454 to +2372°F)
0: Specify
THERMOCOUPLE TRANSMITTER
Functions & Features
• Accepts direct input from a thermocouple and provides a [2] OUTPUT
standard process signal Current
• 5-segment linearization A: 4 – 20 mA DC (Load resistance 750 Ω max.)
• Burnout B: 2 – 10 mA DC (Load resistance 1500 Ω max.)
• High-accuracy cold junction compensation C: 1 – 5 mA DC (Load resistance 3000 Ω max.)
• Fast response type available D: 0 – 20 mA DC (Load resistance 750 Ω max.)
E: 0 – 16 mA DC (Load resistance 900 Ω max.)
Typical Applications F: 0 – 10 mA DC (Load resistance 1500 Ω max.)
• High-accuracy cold junction compensation benefits narrow G: 0 – 1 mA DC (Load resistance 15 kΩ max.)
span measurements Z: Specify current (See OUTPUT SPECIFICATIONS)
• 0.1 μA burnout sensing enables long distance Voltage
transmission with minimum offset drifts 1: 0 – 10 mV DC (Load resistance 10 kΩ min.)
• Electric furnace (isolation ensured even when 200 V AC 2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
power for heater leaks through furnace wall) 3: 0 – 1 V DC (Load resistance 1000 Ω min.)
• No burnout type can connect to a single T/C in parallel 4: 0 – 10 V DC (Load resistance 10 kΩ min.)
with a recorder 5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
23 (.91) 0: Specify voltage (See OUTPUT SPECIFICATIONS)

[3] POWER INPUT


Model
76
(2.99) AC Power
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(Select ‘/N’ for ‘Standards & Approvals’ code.)
ZERO

SPAN
124
(4.88) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
mm (inch)
47 – 66 Hz)
(90 – 264 V for UL)
MODEL: M2TS–[1][2]–[3][4] DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
ORDERING INFORMATION R2: 11 – 27 V DC
• Code number: M2TS-[1][2]-[3][4] (Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
Specify a code from below for each [1] through [4]. (Select ‘/N’ for ‘Standards & Approvals’ code.)
(e.g. M2TS-2A-M2/BL/CE/Q) P: 110 V DC
• Temperature range (e.g. 0 – 800°C) (Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
• Special output range (For codes Z & 0) (110 V ±10 % for UL)
• Specify the specification for option code /Q
(e.g. /C01/V01)
[4] OPTIONS (multiple selections)
Response Time (0 – 90 %)
[1] INPUT THERMOCOUPLE blank: Standard (≤ 0.5 sec.)
1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F) /K: Fast Response (Approx. 25 msec.)
2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F) Burnout
3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F) blank: Upscale burnout
4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F) /BL: Downscale burnout
5: T (CC) (Usable range -270 to +400°C, -454 to +752°F) /BN: No burnout
6: B (RH) (Usable range 0 to 1820°C, 32 to 3308°F) Standards & Approvals (must be specified)
7: R (Usable range -50 to +1760°C, -58 to +3200°F) /N: Without CE or UL

M2TS SPECIFICATIONS ES-5012 Rev.21 Page 1/4

http://www.m-system.co.jp/
MODEL: M2TS
/CE: CE marking MIN. span (in °F)
/UL: UL approval, CE marking (PR): min. span 670°F
Other Options K (CA): min. span 140°F
blank: none E (CRC): min. span 90°F
/Q: Option other than the above (specify the specification) J (IC): min. span 110°F
T (CC): min. span 140°F
B (RH): min. span 1410°F
SPECIFICATIONS OF OPTION: Q (multiple selections)
R: min. span 650°F
COATING (For the detail, refer to M-System's web site.)
S: min. span 690°F
/C01: Silicone coating
N: min. span 200°F
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
Remark: The described accuracy may be partially not
ADJUSTMENT
satisfied when the temperature ranges below 0°C. Consult
/V01: Multi-turn fine adjustment (UL not available)
factory.
/VN: Sealed adjustment holes (UL not available)
TERMINAL SCREW MATERIAL
/S01: Stainless steel (UL not available) OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
GENERAL SPECIFICATIONS
Offset: Max. 1.5 times span
Construction: Plug-in
Load resistance: Output drive 15 V max.
Connection: M3 screw terminals (torque 0.8 N·m)
■ DC Voltage: -10 – +12 V DC
Screw terminal: Chromated steel (standard) or stainless
Minimum span: 5 mV
steel
Offset: Max. 1.5 times span
Housing material: Flame-resistant resin (black)
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V
Isolation: Input to output to power
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front) INSTALLATION
Span adjustment: 95 to 105 % (front) Power Consumption
Burnout: Upscale standard; downscale or no burnout •AC:
optional Approx. 3 VA at 100 V
At burnout: Downscale ≤ -10 %, Upscale ≥ 110 % Approx. 4 VA at 200 V
Linearization: Standard Approx. 5 VA at 264 V
Cold junction compensation: CJC sensor attached to the •DC: Approx. 3 W
input terminals Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
INPUT SPECIFICATIONS
Weight: 150 g (0.33 lb)
Minimum span: 3 mV
Offset: Max. 1.5 times span
Input resistance: 30 kΩ min. PERFORMANCE in percentage of span
Burnout sensing: 0.1 μA Accuracy: ±0.4 % (at over 400°C or 750°F for R, S and PR;
over 770°C or 1420°F for B)
MIN. span (in °C) Cold junction compensation error
(PR): min. span 370°C (at 25°C ±10°C or 77°F ±18°F)
K (CA): min. span 75°C K, E, J, T & N: ±0.5°C or ±0.9°F
E (CRC): min. span 50°C S, R & PR: ±1°C or ±1.8°F
J (IC): min. span 60°C Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
T (CC): min. span 75°C (at over 770°C or 1420°F for B)
B (RH): min. span 780°C Burnout response: ≤ 10 sec.
R: min. span 360°C Line voltage effect: ±0.1 % over voltage range
S: min. span 380°C Insulation resistance: ≥ 100 MΩ with 500 V DC
N: min. span 110°C Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)

M2TS SPECIFICATIONS ES-5012 Rev.21 Page 2/4

http://www.m-system.co.jp/
MODEL: M2TS
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
EN 50581
Approval:
UL/C-UL nonincendive Class I, Division 2,
Groups A, B, C, and D
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)

EXTERNAL DIMENSIONS unit: mm (inch)


6 (.23)

DIN RAIL
35mm wide 4 1
8 5
2–4.2x5
(.17x.20)
70.5 (2.78)

59 (2.32)
72 (2.83)
MTG HOLE
6 (.24) deep

8–M3 12 9
SCREW 14 13

21.5 (.85) 10 (.39) 84 (3.31) 15 (.59)


4 (.16)

114 (4.49) [4 (.16)] 23 (.91)

• When mounting, no extra space is needed between units.

TERMINAL ASSIGNMENTS unit: mm (inch)


CJC SENSOR
(model: CJM)
14 (.55)

4 1 1
8 5

12 9
14 13

M2TS SPECIFICATIONS ES-5012 Rev.21 Page 3/4

http://www.m-system.co.jp/
MODEL: M2TS
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

comp. leadwire Isolation Z S


T/C
+ Low Drift Output
+ 1 Amplifier
Linearizer
Driver
9 +
OUTPUT
– 12 –
metal leg –
4 13 U(+)
CJC POWER
SENSOR CJC Sensing *
5 Volt. Generator
14 V(–)
model: CJM
8

Base Socket
*Deleted with B thermocouple.

Specifications are subject to change without notice.

M2TS SPECIFICATIONS ES-5012 Rev.21 Page 4/4

http://www.m-system.co.jp/