Sonocontrol 14 TD Sonotec

This document provides technical specifications for the SONOCONTROL 14 ultrasonic position switch, which non-contact detects pistons in hydraulic cylinders and accumulators or liquid levels. It uses ultrasonic pulse-echo technology and measures through vessel walls. Models are available for cylinder diameters from 60-1600mm and viscosities to 500cSt. The IP67-rated sensor has an M12 or fixed cable, outputs a switching signal, and can synchronize via a one-wire interface. It is constructed from aluminum or stainless steel and operates from 18-30VDC.

Uploaded by

San Li
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
204 views4 pages

Sonocontrol 14 TD Sonotec

This document provides technical specifications for the SONOCONTROL 14 ultrasonic position switch, which non-contact detects pistons in hydraulic cylinders and accumulators or liquid levels. It uses ultrasonic pulse-echo technology and measures through vessel walls. Models are available for cylinder diameters from 60-1600mm and viscosities to 500cSt. The IP67-rated sensor has an M12 or fixed cable, outputs a switching signal, and can synchronize via a one-wire interface. It is constructed from aluminum or stainless steel and operates from 18-30VDC.

Uploaded by

San Li
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SONOCONTROL 14

Technical Datasheet

SONOCONTROL 14

Rev. 2, Date: 2012-03-16 -1- Technical Datasheet


SONOCONTROL 14

Type of equipment SONOCONTROL 14 Type 1, Type 2, Type 3, Type 4, Type 7:


ultrasonic position switch for
- piston detection in piston accumulators (without piston pole)
- piston detection in hydraulic cylinders
- level control

Sensor construction Compact sensor unit, consisting of sensor element and


evaluation electronics

Measuring principle Contactless ultrasonic impulse echo method


- no contact between sensor and liquid
- no structural changes of the piston accumulator necessary,
since it measures from the outside through the wall

Operating mode / 1 sensor  single operating mode


Number of sensors 2 sensors  synchronous operating mode

Measuring frequency Max. 155 Hz

Attachment at the Mounting at required position with mounting plate + tightening


cylinder/vessel strap + lock
Coupling Coupling with coupling medium to cylinder / vessel

Reproducibility Static  1 mm (at same conditions of measurement)

Specified and (feasible) Type 1, Type 2 and Type 7:


cylinder/vessel External diameter: (60) 98 … 600 (950) mm
dimensions Internal diameter: (50) 70 … 500 (800) mm
Type 3 and Type 4:
External diameter: (150) 200 … 950 (1600) mm
Internal diameter: (120) 160 … 800 (1500) mm

Hydraulic fluid Mineral oil (HL, HLP), HFA, (HFB), HFC, HFD
water and water-like liquids, 20 µm purity

Max. absolute viscosity 100 cSt for Type 1, Type 2, Type 7


500 cSt for Type 3, Type 4

Power supply 18 ... 30 VDC, max. 80 mA, ripple 10 %


- low voltage identification
- inverse-polarity protection
- overvoltage protection

Switching output NPN or PNP


- max. switching voltage: positive operating voltage
- max. switching capacity: 1,8 W (Requires external fuse!)

Serial interface One-wire-interface for synchronisation and configuration


(with programming adapter and PC)

Rev. 2, Date: 2012-03-16 -2- Technical Datasheet


SONOCONTROL 14

Connections Sensor plug-in connector M12 (Type 1, 3, 7) for censor cable


with elbow plug connector or fixed cable (Type 2, 4)
Cable, 4-pole without shielding
Brown: positive operating voltage 18 ... 30 VDC
Blue: negative operating voltage (GND)
Black: switching output
White: synchronisation,
serial programming for configuration

Sensor cable length Type 1, 3, 7: 5 (or 10) meters with elbow plug connector
Type 2, 4: 5 meters of fixed cable

Switching point indicator Type 1, 3, 7: Integrated LED within elbow plug connector
Type 2, 4: Externally only

Temperature range Temperature of cylinder or vessel: -20 ... +80 °C


Ambient temperature: -20 ... +60 °C
Storage temperature: -40 ... +85 °C
Attention: The range of working temperature is further
restricted by the absolute viscosity.

Protection class IP 67, oil resistant

Housing Type 1, 3, 7: Aluminium anodized, earthed against GND


Type 2, 4: Stainless steel 1.4571, earthed against GND

Weight Approx. 170 g … 500 g

CE Conformity Ingress protection: DIN EN 60529:1991 + A1:2000


EMC active: DIN EN 61326-1:2006
EMC passive: IEC61000-4-2, -3, -4, -5, -6

Scope of delivery Sensor, mounting element, coupling medium, connecting


cable, operating manual, optional parameterizing adapter

Configuratio Thread Housing Max. absolute viscosity NPN PNP Ex mb


n
Type 1 M30x1,5 Aluminium 100 cSt x x -
Type 2 M30x1,5 1.4571 100 cSt x x -
Type 3 M45x1,5 Aluminium 500 cSt x x -
Type 4 M45x1,5 1.4571 500 cSt x x -
1
Type 5* M30x1,5 1.4571 100 cSt x x x
1
Type 6* M45x1,5 1.4571 500 cSt x x x
Type 7 M30x1,0 Aluminium 100 cSt x x -

Tab. 1.: SONOCONTROL 14 – Configuration of available types


1
* sensors for hazardous areas, type of ignition protection Ex mb, -> particular datasheet

Rev. 2, Date: 2012-03-16 -3- Technical Datasheet


SONOCONTROL 14

Ø50 Ø50

11
13
36

38
54

63
M30x1,5

M45x1.5

Fig. 1: SONOCONTROL14 sizes (left: Type 1, 2, 7; right: Type 3, 4)


Photo: SONOCONTROL14 Type 1 with elbow plug connector

Fig. 2: pin assignment NPN