SONOCONTROL 14
Technical Datasheet
SONOCONTROL 14
Rev. 2, Date: 2012-03-16 -1- Technical Datasheet
SONOCONTROL 14
Type of equipment SONOCONTROL 14 Type 1, Type 2, Type 3, Type 4, Type 7:
ultrasonic position switch for
- piston detection in piston accumulators (without piston pole)
- piston detection in hydraulic cylinders
- level control
Sensor construction Compact sensor unit, consisting of sensor element and
evaluation electronics
Measuring principle Contactless ultrasonic impulse echo method
- no contact between sensor and liquid
- no structural changes of the piston accumulator necessary,
since it measures from the outside through the wall
Operating mode / 1 sensor single operating mode
Number of sensors 2 sensors synchronous operating mode
Measuring frequency Max. 155 Hz
Attachment at the Mounting at required position with mounting plate + tightening
cylinder/vessel strap + lock
Coupling Coupling with coupling medium to cylinder / vessel
Reproducibility Static 1 mm (at same conditions of measurement)
Specified and (feasible) Type 1, Type 2 and Type 7:
cylinder/vessel External diameter: (60) 98 … 600 (950) mm
dimensions Internal diameter: (50) 70 … 500 (800) mm
Type 3 and Type 4:
External diameter: (150) 200 … 950 (1600) mm
Internal diameter: (120) 160 … 800 (1500) mm
Hydraulic fluid Mineral oil (HL, HLP), HFA, (HFB), HFC, HFD
water and water-like liquids, 20 µm purity
Max. absolute viscosity 100 cSt for Type 1, Type 2, Type 7
500 cSt for Type 3, Type 4
Power supply 18 ... 30 VDC, max. 80 mA, ripple 10 %
- low voltage identification
- inverse-polarity protection
- overvoltage protection
Switching output NPN or PNP
- max. switching voltage: positive operating voltage
- max. switching capacity: 1,8 W (Requires external fuse!)
Serial interface One-wire-interface for synchronisation and configuration
(with programming adapter and PC)
Rev. 2, Date: 2012-03-16 -2- Technical Datasheet
SONOCONTROL 14
Connections Sensor plug-in connector M12 (Type 1, 3, 7) for censor cable
with elbow plug connector or fixed cable (Type 2, 4)
Cable, 4-pole without shielding
Brown: positive operating voltage 18 ... 30 VDC
Blue: negative operating voltage (GND)
Black: switching output
White: synchronisation,
serial programming for configuration
Sensor cable length Type 1, 3, 7: 5 (or 10) meters with elbow plug connector
Type 2, 4: 5 meters of fixed cable
Switching point indicator Type 1, 3, 7: Integrated LED within elbow plug connector
Type 2, 4: Externally only
Temperature range Temperature of cylinder or vessel: -20 ... +80 °C
Ambient temperature: -20 ... +60 °C
Storage temperature: -40 ... +85 °C
Attention: The range of working temperature is further
restricted by the absolute viscosity.
Protection class IP 67, oil resistant
Housing Type 1, 3, 7: Aluminium anodized, earthed against GND
Type 2, 4: Stainless steel 1.4571, earthed against GND
Weight Approx. 170 g … 500 g
CE Conformity Ingress protection: DIN EN 60529:1991 + A1:2000
EMC active: DIN EN 61326-1:2006
EMC passive: IEC61000-4-2, -3, -4, -5, -6
Scope of delivery Sensor, mounting element, coupling medium, connecting
cable, operating manual, optional parameterizing adapter
Configuratio Thread Housing Max. absolute viscosity NPN PNP Ex mb
n
Type 1 M30x1,5 Aluminium 100 cSt x x -
Type 2 M30x1,5 1.4571 100 cSt x x -
Type 3 M45x1,5 Aluminium 500 cSt x x -
Type 4 M45x1,5 1.4571 500 cSt x x -
1
Type 5* M30x1,5 1.4571 100 cSt x x x
1
Type 6* M45x1,5 1.4571 500 cSt x x x
Type 7 M30x1,0 Aluminium 100 cSt x x -
Tab. 1.: SONOCONTROL 14 – Configuration of available types
1
* sensors for hazardous areas, type of ignition protection Ex mb, -> particular datasheet
Rev. 2, Date: 2012-03-16 -3- Technical Datasheet
SONOCONTROL 14
Ø50 Ø50
11
13
36
38
54
63
M30x1,5
M45x1.5
Fig. 1: SONOCONTROL14 sizes (left: Type 1, 2, 7; right: Type 3, 4)
Photo: SONOCONTROL14 Type 1 with elbow plug connector
Fig. 2: pin assignment NPN
Fig. 3: pin assignment PNP
Rev. 2, Date: 2012-03-16 -4- Technical Datasheet