ecocirc XL 50-150 F
ecocirc XL - Performance curves and technical data
E501030AA
[m] Head
15.0
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
Max
1.0 Pump data
0.0
[kW] Power input P1 Make Lowara
1.10 Max (P1) Port to port (mm) 280
1.00
Electrical connection Terminals
0.90
0.80
Specif ic EEI <= 0,23
0.70 Nominal pressure PN 6/10
0.60 Connection Flanged / DN 50
0.50
0.40
Electrical data
0.30
0.20 Rated v oltage 230 V
0.10 Frequenc y 50 / 60
0.00 Protection class IP 44
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 [l/s]
Performance according to ISO 9906:2012 – Grade 3B Liquid temperature: Insulation class F
Power datas referced to: -10 ° C (14° F) to +110 ° C (230 ° F) for heating pumps
Water, pure [100% ] ; 4°C; 1000kg/m³; 1.57mm²/s -10 ° C (14° F) to +85 ° C (185° F) for domestic hot water pumps Digital input Contact load: 5V, 10 mA
Digital output Vmax < 250 VAC / Imax < 2 A
Materials Analog input 0-10 V / 4-20 mA
Bush Bearing Carbon, resin impregnated Impeller PPS Leakage current < 3.5 mA
Thrust bearing Aluminium Wear Ring Stainless steel Communication capabilities No communication protocol
Bearing plate Stainless steel Rotor can Stainless steel Sound pressure lev el <= 52 dB(A)
Motor housing Aluminum Shaf t Stainless steel Rated current 5.1 A
O-rings EPDM Control box Poly carbonate
PUMP HOUSING Cast Iron Dimensions mm
B1 386
B2 314
B3 72
B4 147
B5 61
C3 146
C4 242
C5 96
D1 165
D2 50
D3 110/125
D4 4 x 14/19
D5 99
G DN 50
Gross Weight 26.4
H1 273
H2 87
H3 107/125
H4 103
L 280
Net Weight 22.6
Page 1 / 1