Suggested Wiring SZ-7520T (230Vac)                                                                         USER INTERFACE                                     3 P2 Parameter Function: To set maximum allowable high
SZ-7520T / SZ-7529T                                                                                                                                                                                                                                                                temperature limit.
                                                                                                                                      230VAC                                                    UP          In Program mode:
                                                                                                                                                        COMP
Operating Instructions                                                                                      PROBE                     50-60Hz
                                                                                                                                                      NC NO C
                                                                                                                                                                                                            Scroll through parameters & Increases                   To change value use               keys To set value touch "SET" key
                                                                                                                                                                                                            parameter value.
                                                                                                             1    2               3             5       6           7          8
                                                                                                                                                                                                            In Set mode : Increases parameter value.                Example: If this parameter is set to 50OC and the temperature
                                                                                                                                                                                                                                                                    reaches or goes above 50OC, display will show Ht (High Temp.)
                                                                                                                                                                                         PRG    Down/   Touch and hold for 2sec to enter into program               indicating that the temperature has reached or gone above the
                                                                                                                                                    To Compressor
                                                                                                                                                                                                Program mode.
                                                                                                                                                     8(3)A 250VAC
                                                                                                                                                                                                                                                                    value set in this parameter.
                                                                                                                                                                                                            In program mode and set mode:
                                                                                                                                                          max
                                                                                                          TO SZ-T75
                                                                                                                                                                                                            Decreases parameter value                                                                                 Min      Max     Fac.
                                                                                                                                                                    To Compressor
                                                                                                                                                                     20A(8)250VAC
that the compressor cuts off at set point and is restarted at a temperature                                                                                                              No.
of set point + differential.                                                                                                                                                                                                                                        Once set at a particular value, this will not allow the set point to
                                                                                                                                                                         max
                                                                                                            TO SZ-T75                                                                     1 Set Point         Compressor relay set point.                           go above this value.
Their operation is very user friendly and is easily understood with the                                                                                                                   2                   Set other parameter.
examples in the instructions below.
                                                                                                                                                                                                                                                                    Example: Setting this parameter at 25°C will not allow the set
                                                                                                 PHASE                                                                                    3    P2             High temperature limit.                               point to go above 24°C (HS-1).          Min Max Fac.
Various parameters help set up the instruments functions for different                           NEUTRAL                                                                                  4    P3             Low temperature limit.                                                                                             O       O
applications.                                                                                                                                                                                                                                                                                                         SP+1     99 C    99 C
                                                                                                                                                                                          5   HS              Maximum Set Point limit.                                                          SP = Set Point
                                                                                                          Caution:Wiring for 230Vac load only
The SZ-7520T/7529T is specifically designed for defrost applications                                                                                                                                                                                                6 LS Parameter Function: To set Minimum set point limit.
                                                                                                                                                                                          6    LS             Minimum Set Point limit.
with a measuring range from -45OC to 99OC.                                                                       Suggested Wiring SZ-7520T                                                7    P4             Differential for compressor relay ON condition.       Once set at a particular value, this will not allow the set point to
                                              CAUTION                                                                                                                                     8    P5             Probe calibration.                                    go below this value.
                                                                                                                                      POWER             COMP
WIRING: The probe and its corresponding wires should never be                                               PROBE                     SUPPLY          NC NO C                             9    P6             Time delay (compressor relay restart after cutoff).   Example: Setting this parameter at -10°C will not allow the
installed in a conduit next to control or power supply lines. The electrical
                                                                                                                                                                                                              Minimum ON time for compressor relay.
                                                                                                                                                                                                                                                                    set point to go below -9°C (LS+1).
wiring should be done as shown in the diagram. The power supply circuit                                      1    2               3             5       6           7          8         10    Ot                                                                                                                 Min Max Fac.
should be connected to a protection switch. The terminals admit wires of                                                                                                                 11    E1             Compressor relay status in probe fail.                                                                  -40OC    SP-1    -40OC
upto 2.5sq mm.                                                                                                                                                                                                                                                                                  SP = Set Point
                                                                                                                                                                                         12    Cn             Compressor relay OFF time during probe fault.
                                                                                                                                                    To Compressor
                                                                                                                                                                                                                                                                    7 P4 Parameter Function: To set the differential for
                                                                                                                                                     8(3)A 250VAC
WARNING: Improper wiring may cause irreparable damage and                                                                                                                                13    Cy             Compressor relay ON time during probe fault.                         compressor relay ON condition.
                                                                                                                                                          max
personal injury. Kindly ensure that wiring is done by qualified personnel                                 TO SZ-T75
                                                                                                                                                                                         14    P7             Duration for Defrost Cycle.
only.                                                                                                                                                                                                                                                               Example : If the set point is set at 10OC and differential is set at
                                                                                                                                                                                         15    P8             Frequency for Defrost Cycle.                          2OC, then when the system reaches 10OC, the compressor
Maintenance: Cleaning: Clean the surface of the controller with a soft                            PHASE
moist cloth. Do not use abrasive detergents, petrol, alcohol or solvents.                                                                                                                16    dF             Display while the Defrost Cycle is in progress.       relay will go OFF. Since the differential is 2OC, the compressor
                                                                                                  NEUTRAL
Notice: The information in this document is subject to change in order to                                                                                                                17    dd             Delay the display of temperature.                     relay will come ON (restart) at 12OC (10OC +2OC).
improve reliability , design or function without prior notice and does not                                       12Vac/dc or 24Vac/dc or 48Vdc
represent a commitment on the part of the company. In no event will the                                                                                                                  18    Ad             Time delay at Power ON for alarm indication.                                                            Min      Max     Fac.
company be liable for direct, indirect, special, incidental or consequential                                                                                                             19    PA             Change Password
damage arising out of the use or inability to use the product or
                                                                                                                 Suggested Wiring SZ-7529T                                                                                                                                                                             1OC     20OC     2OC
documentation, even if advised of the possibility of such damages. No                                                                                                                    20    LP             Keypad Lock
                                                                                                                                                                                                                                                                    8 P5 Parameter Function: To set probe calibration.
part of this manual may be reproduced or transmitted in any form or by                                                                                                                   21    FS             Restore factory defaults
                                                                                                                            POWER
any means without the prior written permission of the company.                                              PROBE           SUPPLY                  COMPRESSOR                                                                                                      In time it may be possible that the display may be offset by a
                                                                                                                                                                                         22    EP             End Programming
Installation : Fixing and dimensions of panel models:                                                        1     2    3             5                                                                                                                             degree or so.
To fix the unit, slide the fastener 1 through the guides 2 as per the
                                                                                                                                                    C                               NO   23                   LED Indications
                                                                                                                                                                                                                                                                    To compensate for this error, user may need to add or minus
position shown in the figure. Move the fastener in the direction of the                                                                                                                                       Operating Messages (Normal Mode)                      the degrees required to achieve the correct temperature.
arrow, pressing tab 3 it permits to move the fastener in the opposite
                                                                                                                                                                                                              Operating Messages (Pro-key Mode)                     Example : The temperature on the display is 28OC, whereas
                                                                                                                                                                    To Compressor
                                                                                                                                                                                                              Password Function                                     the actual temperature is 30OC. User will have to set the P5
                                                                                                                                                                         max
Controller :Controller should be installed in a place protected by                                          TO SZ-T75                                                                                                                                               parameter to 2, which means that once out of the programming
vibration, water and corrosive gasses and where ambient temperature
                                                                                                                                                                                                              Temperature Logging
does not exceed the values specified in the technical data.                                                                                                                                                   User Selectable Default Values                        mode, the temperature on display will be 30OC (28OC+ 2OC).
                                                                                                 PHASE
                                                                                                                                                                                                                                                                                                                      Min     Max      Fac.
Probe :To give a correct reading, the probe must be installed in a place                         NEUTRAL                                                                                 Parameter List :
protected from thermal influences, which may affect the temperature to                                                                                                                                                                                                                                                  O
                                                                                                                                                                                                                                                                                                                      -10 C
                                                                                                                                                                                                                                                                                                                                O
                                                                                                                                                                                                                                                                                                                              10 C
                                                                                                                                                                                                                                                                                                                                        O
                                                                                                                                                                                                                                                                                                                                       0C
be controlled.                                                                                           12Vac/dc or 24Vac/dc or 48Vdc or 110Vac                                         1 Set point            Function: To set compressor relay set point.        9 P6 Parameter Function: To set time delay between
Panel Cutout and Dimensions :                                                                                           TECHNICAL DATA                                                                                 SET                                                         compressor relay restart.
                                                                               MAX
                                                                               10mm                                                                                                                     Touch & hold         key for 2 seconds.                     This parameter is used to protect the compressor from
                                                    2      1                                 Housing            : Black ABS Plastic, Auto-extinguish
                                                                       3
                                                                                             Front Cover        : Polycarbonate Plastic                                                                                                                             restarting in a short period of time.
                                                                                             Dimensions         : Frontal : 78 X 36mm, Depth : 59mm                                      Display will show set value. The set point value can now be                Example: If this parameter is set at 3 minutes, the compressor
             Panel cutout
71mm
                                                                                             Panel Cutout       : 29 X 71mm                                                              modified by using the UP/DOWN key. After selecting the desired             relay goes OFF at the set point, it will not restart for a minimum
                                                                                      36mm   Mounting           : Flush panel mounting with fasteners                                    value, touch the set key and user can see "- -" which confirms that        of 3 minutes, even if the differential is achieved earlier. This
                                                                                             Protection         : IP65 Front (with gasket)                                               the set point has been stored in memory.                                   parameter is good to protect the life of the compressor.
                                                                                             Connections        : Screw terminal blocks.
                                                                                                                  < 2.5sq mm terminal only.                                                                                                    Min Max Fac.                                                           Min     Max      Fac.
                                                               59 mm                         Display            : 2 X 17mm 7 segment display &                                                                                                                  O                                Flashing             0 Min   99 Min   3 Min
                                                                                                                                                                                                                                               LS+1 HS-1     0C
           29mm                                                                                                                                                                                                                                                                              Time delay in progress
                                                                                                                  5 LEDs for Indication
                                                                   Side Lock
                                                                                             Data storage       : Non-volatile EEPROM memory                                             2 To set other                                                             10 Ot Parameter Function: Minimum ON Time For
                                      PANEL                                                                                                                                                                    Display will flash “P2”.
                                                                                             Power input        : 230 Vac ±15 % , 50-60Hz.                                                 Parameters.         To select other parameters, use UP/DOWN                              Compressor relay.
                                                                                                                  Others on request.                                                       Touch & hold        keys.                                                This parameter is used to protect the compressor so that there
                            GASKET                                                           Relay output       : Comp SPST relay 20(8)A,250V AC (for SZ-7529T)                                                                                                     is enough time for oil to return back to the compressor. This
                                                                                                                  Comp SPDT relay 8(3)A,250V AC (for SZ-7520T)                                                                                                      delay starts once the compressor relay is ON.
                                                                                             Operating temp.    : 0°C to 60°C (non-condensing)
                                                                                             Operating humidity : 20% to 85% (non-condensing)
                                                                                                                                                                                                                                                                    Example: If this parameter is set at 1Min and if the
                                                                                                                                                                                                 key for                                                            temperature is achieved before 1 minute, then the compressor
                                                                                             Storage temp       : -25°C to 60°C (non-condensing)                                               2 seconds.
                                                                                             Measuring Range : -45°C to 99°C
                                                                                                                                                                                                                                                                    relay will remain ON for minimum 1 minute, though set point is
                                                                                             Input              : NTC probe, SZ-T75
                                                                                                                                                                                                                                                                    achieved.
                                                                                                                                                                                                                                                                                                               Min Max Fac.
                                                                                             Resolution         : +/- 1°C
                                                                                             Accuracy           : +/- 1°C                                                                                                                                                                                             0 Min   20 Min   0 Min
                                              CONTROLLER
11 E1 Parameter Function : Compressor relay status in case          18 Ad Parameter Function : This parameter is used to set the                    OPERATING MESSAGES (Normal Mode)                                  User selectable Default values
                of Probe Failure.                                                   time delay at Power ON for Alarm Indication.
                                                                                                                                                                                                                      User can set their own set of Default Set values for all parameters. If
When set to
                                                                                                                                             Ht   High temperature alarm         Lt   Low temperature alarm
                                                                                                                                                                                                                      user wants to activate this feature, Program mode must be
                                                                    Example: If this parameter is set to 20 minutes, once the                     Temperature above the               Temperature below the
0 = Compressor relay status is OFF.                                 controller is powered ON, no fault indication will be activated for                                                                               accessed and then change Factory set (FS) parameter
                                                                                                                                                  maximum high                        minimum low
1 = Compressor relay status is ON.                                  20 minutes.                                                                                                                                       accordingly.
                                                                                                                                                  temperature limit.                  temperature limit.
2 = Compressor relay performs a duty cycle for Cn for
minutes OFF and Cy for minutes ON.                                  Alarm delay is used only for High Temperature and Low                    PP Probe fail                       LP    Keypad lock                    This can be done by following steps:
                                                                    Temperature, but not for Room Sensor fail.                                    Probe short circuit, circuit         Keypad is locked
                                            Min    Max     Fac.                                                                                   open or without probe, or
                                                                    If Control Probe Temperature reaches or goes above P2                         temperature is > 990C or                                              Modify values of set point and other parameters as desired by
                                             0        2     2       parameter value, High Temperature (Ht) fault will displayed.                                                                                        entering set mode and program mode respectively.
                                                                                                                                                  <-400C
12 Cn Parameter Function : Compressor relay OFF Time                                                                                                                                                                    Select FS parameter and touch "SET" key. While display
                during probe fault.
                                                                    If Control Probe Temperature reaches or drops below P3                   LL   Last low temperature           LH    Last high temperature
                                                                                                                                                                                                                        flashing “0” , touch and hold "   " for 10sec. Controller will flash
                                                                    parameter value, Low Temperature (Lt) fault will displayed.                   Last low temperature                 Last high temperature
                                                                                                                                                  logged.                              logged.                          "-2". Then touch "SET" key. All the user defined parameter
(This will be considered only when E1 is selected 2 ) .             Differential of 1OC is considered for clearing the fault.                                                                                           values will be stored as ‘User Default set’.
Example : If this parameter is set to 4 minutes, then                                                                 Min   Max     Fac.     rS   In log function: When LL       dF    Defrost                          If user wants to use this set of parameters, access Program
                                                                                                                                                  and LH values are cleared.           Defrost in progress.             mode and set the FS parameter to "2". Controller will restore the
compressor relay will be OFF for 4 minutes while performing                                          ON
                                                                                                                      0 Min 99 Min 0 Min                                                                                user defined parameter values.
the duty cycle.                                                                               Fault is present
                                        Min Max Fac.                19 PA Parameter Function : To change Password.                                  OPERATING MESSAGES (Pro-key Mode)
                                                                                                                                                                                                                        (Note: Keypad parameter LP and User lock parameter will be
                                           1 Min 99 Min 4 Min
                                                                                                                                             Pr   Shows controller in Pro-       uP Shows selection of                  taken into consideration while modifying this parameter.)
13 Cy Parameter Function : Compressor relay ON Time                 User cannot enter into program mode & set mode, if correct                    key mode.                           uploading mode, parameter
                during probe fault.                                 password is not entered.                                                                                          values can be uploaded          Disclaimer: This manual & its contents remain the sole property of
                                                                                                                                                                                      from controller to pro key.     PVR CONTROLS . India and shall not be reproduced or
(This will be considered only when E1 is selected 2 ) .             If the password is kept other then 0, user need to enter correct         dn Shows selection of down          En Shows the Pro-key is              distributed without authorization. Although great care has been
Example : If this parameter is set to 10 minutes, then              password to enter into set/program mode.                                      loading mode, parameter             validated by controller.        taken in the preparation of this document, the company or its
compressor relay will be ON for 10 minutes while performing                                                                                       values can be down loaded                                           vendors in no event will be liable for direct, indirect, special,
the duty cycle.                                                     If password is 0, user can directly access set/program mode.                  from pro key to controller.                                         incidental or consequential damage arising out of the use or
                                           Min Max Fac.                                                                                                                                                               inability to use the product or documentation, even if advised of the
                                                                                                                      Min   Max     Fac.     Er   Shows an error in Pro-         CL User lock is active.              possibility of such damages. No part of this manual may be
                                           1 Min 99 Min 10 Min                                                                                    key validation / error in
                                                                                                                      -99    99      0                                                                                reproduced or transmitted in any form or by any means without the
                                                                                                                                                  uploading or down loading
14 P7 Parameter Function : This Parameter is used to set the                                                                                                                                                          prior written permission of the company. PVR CONTROLS.,
                                                                    20 LP Parameter Function: To lock keypad.                                     parameters/error in setting
                Duration for Defrost Cycle.                                                                                                       user lock function.                                                 reserves the right to make and changes or improvements without
                                                                                                                                                                                                                      prior notice.
This paramter is applicable for both Auto and Manal Defrost         This parameter is used to lock the keypad so that tampering is           UL User lock is not active.                                              Warranty: This product is warranted against defects in materials
and specifies for how much time the Defrost will last.              not possible by by-standers.
                                                                                                                                             Password function                                                        and workmanship for a period of one year from the date of
Example : If this parameter is set to 30 Minutes and Defrost        0 = keypad unlocked                                                                                                                               purchase. During the warranty period, product determined by us to
Frequency means P8 parameter is set to 1 Hour, then 1 Hour          1 = keypad locked                                                         In Program mode:
                                                                                                                                                                                                                      be defective in form or function will be repaired or, at our option,
after Power is applied to the controller, defrost will take place   When locked all parameters can only be viewed, but not                      Touch & hold "       " key for 2sec. Display will flash "P2"
                                                                                                                                                                                                                      replaced at no charge. This warranty does not apply if the product
for 30 minutes. This Cycle will repeat after every 1 Hour.          modified.                                                                   parameter if "PA" value is kept "0". If other than "0", then "PA'
                                                                                                                                                                                                                      has been damaged by accident, abuse, and misuse or as a result of
                                            Min    Max     Fac.                                                                                 and "0" will flash. Use " "and " " keys to enter the                  service or modification other than by the company. This warranty is
                               ON                                   Note : If LP parameter is set to 1 and if user tries to change any          password. On entering correct value, display will flash the first     in lieu of any other warranty expressed or implied. In no event shall
                       Defrost in Progress 0 Min 99 Min 30 Min      parameter value, " LP" will flash on the display.                           parameter "P2". User can scroll through parameters using              the company be held liable for incidental or consequential
15 P8 Parameter Function : This Parameter is used to set the                                                          Min   Max     Fac.        " " or "       " keys.                                                damages, including lost revenue or lost business opportunity
                frequency for Defrost Cycle.                                                                                                  In Set mode:
                                                                                                   Flashing            0      1      0                                                                                arising from the purchase of this product.
This parameter is applicable only for Auto Defrost.                                                                                             Touch & hold "SET" key for 2sec. Display will flash set point
                                                                    21 FS Parameter Function : To restore default settings of the
Example : As explained for P7 parameter.                                                                                                        value if “PA” parameter value is kept to “0”. If other than “0”,                            OUR OTHER PRODUCTS
                                                                                    controller.
                                                                                                                                                then display will flash “PA” and “0”. Use " " or "       " to enter                           TM
Min Max Fac. When set to 1 all parameters are programmed to factory set the password. On entering correct value, display will flash set R
                                                                    values.
                                           1 Hr    31 Hr   6 Hr                                                                                 point value. User can set desired value using "       "or "    "
                                                                    Useful to debug setting related Problems.
16 dF Parameter Function : This parameter is used to select                                                                                     keys. To save the modified value use "SET" key.
                                                                    When set to,                                                                                                                                             Cold Room Controller
                display while the Defrost Cycle is in                                                                                        High and Low temperature logging function                                                                               Ball Valves
                progress.                                           0 = FS is disable.                                                                                                                                         Chiller Controller                  Globe Valves
                                                                    1 = FS as per default value.                                               How to see the logged values:                                               Two Compressor Controller                Hand Valves
                                                                                                                      Min   Max     Fac.
Example : When this parameter is set to,                            2 = FS as per user define                                                                                                                                  Heating Controller                  Flow Switches
                                                                                                                                                LL : Last Low temperature
                                                                                                                       0      2      0                                                                                        Humidity Controller                 Solenoid Valves
0: While the Defrost is ON , Control Probe temperature will be                                                                                  LH : Last High temperature                                                    Pressure Controller
   displayed.                                                       22 EP Parameter Function: To end programming.                                 Touch and hold " " key for 1sec. display will flash “LL” and
                                                                                                                                                                                                                                                                                 03 / 09.10.18
                                                                                                                                                  the corresponding temperature for 4 seconds. After this,
1: While the Defrost is ON, "dF" will be displayed.                 To end             Once the key is pressed, the controller goes
                                                                    programming                                                                   display will flash “LH” and the corresponding temperature for
                                                                                       into the normal mode and displays the
                                            Min    Max     Fac.     press "SET" key    temperature and all settings are recorded.                 4 seconds and come out of Log mode and will display
                                                                                                                                                  Control probe temperature.
                                             0        1     0
                                                                                                   LEDS                                        How to reset the Logged values
17 dd Parameter Function : This parameter is used to delay                                                                                       While the display is showing the logged values, if user
                the display of temperature by the set in                Compressor                            Alarm                              touches & holds the "SET" key for 1sec, the logged values will
                this parameter.                                         ON:      Compressor is ON.            ON:      Alarm relay ON.           be cleared and "rS" will be displayed.
Each value corresponds to 5 seconds, if the value is set to 1, it       OFF:     Compressor is OFF.           OFF:     Alarm relay OFF.
                                                                                                                                               Log Values will get reset after Power ON/OFF.
corresponds to 5 seconds, if it is set to 2, it corresponds to 10
                                                                        Time Delay                            Defrost
seconds and so on.
                                                                        ON:    Compressor is ON               ON:     Defrost in progress.
For example, if this parameter is set to 1, temperature on the                 and in time delay
display will be updated after 5 seconds. The same value will be                for switching OFF.
considered for calculation and logging.                                        (Ot parameter)
Display delay parameter is applicable only when temperature             FLASHING:
                                                                               Compressor is in
is increasing (rising). When temperature is decreasing (falling)
                                                                               time delay and
this parameter will not be applicable.                                         about to start.
If this parameter is set to 0, this feature will be disabled.
                                                                          ON:     When temperature is displayed.
                                            Min    Max     Fac.
                                             0        36    0