100% found this document useful (1 vote)
159 views2 pages

Electromagnetic Flowmeter Datasheet

This document provides datasheets for three electromagnetic flowmeters used to measure flow of different chemicals. Flowmeter 1 measures an EDTA solution, flowmeter 2 measures soft water, and flowmeter 3 measures triethylamine. The datasheets specify details like line size and material, flow ranges and conditions, power supply, outputs, enclosure type, and manufacturer. Key flowmeter details like type, accuracy, and materials of construction are left for the vendor to specify.

Uploaded by

Karthikeyan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
159 views2 pages

Electromagnetic Flowmeter Datasheet

This document provides datasheets for three electromagnetic flowmeters used to measure flow of different chemicals. Flowmeter 1 measures an EDTA solution, flowmeter 2 measures soft water, and flowmeter 3 measures triethylamine. The datasheets specify details like line size and material, flow ranges and conditions, power supply, outputs, enclosure type, and manufacturer. Key flowmeter details like type, accuracy, and materials of construction are left for the vendor to specify.

Uploaded by

Karthikeyan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SHEET 1 OF 2

DATASHEET FOR ELECTRO-MAGNETIC FLOWMETER


1 R 2 R
G
1 TAG NO. FT-10204 FT-10205
E
2 P&ID NO. XXXXXXXXXX XXXXXXXXXXXX
N
3 SERVICE EDTA (39%) SOFT WATER
E
4 LINE NO. 40-EDT-102009-XXX 50-SF-102012-XXX
R
5 LINE SIZE(mm), SCH., RATING 40, SCH 80, 150# 50, SCH 10S, 150#
A
6 LINE MATERIAL ASTM A53 GR. B ASTM A 312 TP 304
L
7
8 FLUID COMPOSITION EDTA (39%), WATER SOFT WATER
S
E 9 FLUID STATE LIQUID LIQUID
R 10 TYPE OF FLOW * *
V 11 MIN NOR MAX MIN NOR MAX
I 3 8.5 10 11 5 8 12
12FLOW m /hr
C 13UPSTREAM PRESSURE kg/cm2 a - 1.2 - - 4 -
E 0 25 35 45 25 35 45
14TEMPERATURE (MAX) C
15CONDUCTIVITY µS/cm CLIENT TO SPECIFY CLIENT TO SPECIFY
D 16VISCOSITY cP 1.1 1
A 17DENSITY kg/m
3 1300 1000
T 18SP.GRAVITY 1.1 1
A 19DESIGN PRESS. / TEMP. kg/cm2 a 0C 1.5 60 5 60
20AMBIENTPRESS. / TEMP. kg/cm2 a 0C ATM 15 TO 45 ATM 15 TO 45
21TYPE 4 WIRE, SMART 4 WIRE, SMART
22METER LOCATION INLINE INLINE
23TRANSMITTER MOUNTING INTEGRAL INTEGRAL
24 INSTRUM : SIZE (mm) * *
ENT
25 : TYPE / RATING #150 FLANGE, ANSI B16.5, RF #150 FLANGE, ANSI B16.5, RF
CONNECT
26 ION
27 MATERIAL : BODY DIE CAST ALUMINUM DIE CAST ALUMINUM
T 28 OF : FLANGE SS316* SS316*
R 29 CONSTRU : LINER * *
A 30 C-TION : ELECTRODE * *
N 31 (MOC) : EARTHING RING * *
S 32
FLOW RANGE
CALIBRATION m3/hr 0 - 20 0 - 20
M 33 MEASURABLE m3/hr * *
I 34 EXCITATION * *
T 35 K-FACTOR (CYCLES/UNIT VOL.) * *
T 36 ACCURACY ±0.5% of MEASURED VALUE ±0.5% of MEASURED VALUE
E 37 REPEATABILITY MFR. STD. MFR. STD.
R 38 POWER SUPPLY 24VDC 24VDC
39 OUTPUT 4-20 mA, HART 4-20 mA, HART
40 ENCLOSURE MOC RATING SS IP 65 SS IP 65
41 ELECTRICAL AREA CLASSIFICATION ZONE-2, GROUP IIC, TEMP. T6 ZONE-2, GROUP IIC, TEMP. T6
42 ELECTRICAL EX. PROTECTION Ex 'd' Ex 'd'
43 CABLE LENGTH (REMOTE MOUNTING) 10 Mtr. 10 Mtr.
44 CABLE ENTRIES 1/2" NPTF, 3 nos. 1/2" NPTF, 3 nos.
45 DISPLAY BACKLIT LCD + KEYPAD BACKLIT LCD + KEYPAD
46
47 MANUFACTURER * *
M
48 METER MODEL NO. * *
I
49 TRANSMITTER MODEL NO. * *
S
50
C
51
NOTE:
* VENDOR TO SPECIFY / CONFIRM
MOC - MATERIAL OF CONSTRUCTION
SHEET 2 OF 2

DATASHEET FOR ELECTRO-MAGNETIC FLOWMETER


3 R R
G
1 TAG NO. FT-10211
E
2 P&ID NO. XXXXXXXXXXXXXXXXXX
N
3 SERVICE TRIETHYL AMINE
E
4 LINE NO. 50-TEA-102033-XXX
R
5 LINE SIZE, SCH., RATING 50, SCH 40, 150#
A
6 LINE MATERIAL ASTM A53 Gr. B
L
7
8 FLUID COMPOSITION TRIETHYL AMINE
S
E 9 FLUID STATE LIQUID
R 10 TYPE OF FLOW *
V 11 MIN NOR MAX
I 3 0.8 1 1.5
12 FLOW m /hr
C 13 UPSTREAM PRESSURE kg/cm2 a - 1.2 -
E 0 25 35 45
14 TEMPERATURE (MAX) C
15 CONDUCTIVITY µS/cm CLIENT TO SPECIFY
D 16 VISCOSITY cP 404
A 17 DENSITY kg/m
3 1100
T 18 SP.GRAVITY 1.1
A 19 DESIGN PRESS. / TEMP. kg/cm2 a 0C 1.5 60
20 AMBIENTPRESS. / TEMP. kg/cm2 a 0C ATM 15 TO 45
21 TYPE 4 WIRE, SMART
22 METER LOCATION INLINE
23 TRANSMITTER MOUNTING INTEGRAL
24 PROCESS : SIZE (mm) *
25 CONNECT : TYPE / RATING #150 FLANGE, ANSI B16.5, RF
26 ION
27 MATERIAL : BODY DIE CAST ALUMINUM
28 OF : FLANGE SS316*
T
29 CONSTRU : LINER *
R
30 C-TION : ELECTRODE *
A (MOC) : EARTHING RING
31 *
N 3
32 CALIBRATION m /hr 0-2
S FLOW RANGE
M
33 MEASURABLE m3/hr *
34 EXCITATION *
I
35 K-FACTOR (CYCLES/UNIT VOL.) *
T
36 ACCURACY ±0.5% of MEASURED VALUE
T
37 REPEATABILITY MFR. STD.
E
24VDC
R 38 POWER SUPPLY
39 OUTPUT 4-20 mA, HART
40 ENCLOSURE MOC RATING SS IP 65
41 ELECTRICAL AREA CLASSIFICATION ZONE-2, GROUP IIC, TEMP. T6
42 ELECTRICAL EX. PROTECTION Ex ' d'
43 CABLE LENGTH (REMOTE MOUNTING) 10 Mtr.
44 CABLE ENTRIES 1/2" NPTF, 3 nos.
45 DISPLAY BACKLIT LCD + KEYPAD
46
47 MANUFACTURER *
M
48 METER MODEL NO. *
I
49 TRANSMITTER MODEL NO. *
S
50
C
51
NOTE:
* VENDOR TO SPECIFY / CONFIRM
MOC - MATERIAL OF CONSTRUCTION

You might also like