Time Swtiches Catalog
Time Swtiches Catalog
P140626
P140627
P111624
P111626
IHP 1c IHP 2c IHP+1c IHP+2c
Automatically switch On and Off loads according to the program entered by the user with 4 keys and
a display, they operate on a weekly cycle: the same program is repeated week after week.
P111633
059236N
P131536
IHP 1c/+ 1c
Automatically switch On and Off loads according to the program entered by the user with 4 keys
and a display, they operate on a weekly cycle: the same program is repeated week after week.
P116862
P116616
P111614
P111613
IH 60mn 1c SRM IH 24h 1c SRM/ ARM IH 24h 2c ARM IH 24h 1c SRM/ ARM IHH 7j 1c ARM
Automatically switch On and Off loads according
P116619
P116863
P140489
ITA 1C ITA 4C
They operate on an daily, weekly or yearly program
(ITA 1c: 1 channel, ITA 4c: 1, 2, 3 or 4 channels - 2 external inputs).
Selection table
The time switches control opening and closing of one or more separate circuits according to a programming pre-set by the user:
bb by memorisation of On and Off switching operations for the IHP and ITA digital time switches
bb by positioning of jumpers or captive segments on a programming dial for the IH mechanical time switches.
An IHP, IH or ITA time switch is chosen according to the following criteria:
Designation Number Cycle Minimum Number Saving Width Override Output contact Time changeover
of period time between of switching on mains (modules controls changeover (summer / winter)
channels (d: day) 2 switching operations cut off of 9 mm) On / Off switch
operations (cos j =1)
(1) The IHP DCF can be synchronised on the Frankfurt 's DCF77 radio station via the ANT DCF antenna.
(2) The ITA 1c and ITA 4c can be synchronised on the Frankfurt 's DCF77 radio station via the DCF antenna for ITA or GPS antenna for ITA.
(3) Summer/Winter-Time can be set to auto without any antenna.
(4) 110 h for 100 V CA supply voltage.
bb bb (12)
CCT15854 (11)
bb CCT15338
bb CCT16364
bb CCT15365
15337
bb CCT15367
15366
15331
15336
15335
(5) Function included and can be realized through special program entry.
(6) English, Russian, Ukrainian, Latvian, Lituanien, Estonian languages.
(7) English, Bulgarian, Greek, Slovene, Serbian, Croatian languages.
(8) English, Hungarian, Polish, Romanian, Czech, Slovak languages.
(9) French, English, Italian, Spanish, German, Portuguese languages.
(10) French, English, Swedish, Dutch, Finnish, Norwegian/Danish languages.
(11) French, English, Italian, Spanish, German, Portuguese, Dutch languages.
(12) Memory key (CCT15861) is not supplied with IHP 1c 18mm (CCT15854) but this memory key and the programming kit (CCT15860) can be used and operate
on IHP 1c 18mm (see "Accessories selection table").
(13) Memory key (CCT15955) is not supplied with ITA 1c /4c but this memory key and the programming kit (CCT15950) can be used and operate on ITA 1c/4c
(see "Accessories selection table").
P140627
P111624
P111626
Function
bb These time switches automatically switch on and off loads according to the program entered by the user
bb They operate on weekly cycle: the same program is repeated week after week
bb They offer automatic summer/winter time change and allow to adjust it according to where you are located
bb The program can be overriden temporary or permanently by pressing 2 keys on the product
bb They also offer holidays program, by configuring the starting and ending dates of the absence.
bb A memory key and a programming kit can be used to duplicate on another IHP+
or to save the program created by the contractor (see "Accessories selection table")
bb Override control with switch or push-button via external input ( 1 external input for
IHP+1c and 2 externals inputs for IHP+ 2c)
Wiring diagrams
L 1 3 5
Ext1&2
N 2 4 6
L N
Catalogue numbers CCT15400 (1) CCT15420 (2) CCT15402 (1) CCT15422 (2) CCT15401 (1) CCT15421 (2) CCT15403 (1) CCT15423 (2)
CCT15450 (3) CCT15720 (4) CCT15452 (3) CCT15722 (4) CCT15451 (3) CCT15721 (4) CCT15453 (3) CCT15723 (4)
CCT15850 (5) CCT15852 (5) CCT15851 (5) CCT15853 (5)
Technical specifications
Voltage rating (Ue) 230 V AC, ±10 %, 50/60 Hz 230 V AC, ±10 %, 50/60 Hz 230 V AC, ±10 %, 50/60 Hz 230 V AC, ±10 %, 50/60 Hz
Consumption 4 VA 7 VA 4 VA 7 VA
(1) English, russian, ukrainian, latvian, lituanien, estonian. (2) English, bulgarian, greek, slovene, serbian, croatian. (3) English, hungarian, polish, romanian, czech,
slovak. (4) French, english, italian, spanish, german, portuguese. (5) French, english, swedish, dutch, finnish, norwegian/danish.
P111630
P131535
P140490
P140489
bb Weekly or yearly time programming bb Weekly or yearly time programming
to be distributed over 1 channel to be distributed over 1, 2, 3 or 4
channels
bb Override control with switch
or push-button via external inputs
bb A memory key and a programming bb A memory key and a programming kit can be used to duplicate on another ITA
kit can be used to duplicate on or to save the program created by the user (see "Accessories selection table").
another IHP or to save the program
created by the contractor (see
"Accessories selection table")
5 6 L
10 11 12 13 14 15 16 17 18
Ext2
C D
A B
Ext1
1 2 3 N 1 2 3 L N 6 7 8 9
230 V AC, ±10 %, 50/60 Hz 230 V AC, +10 %, 230 V AC, +10 %, 230 V AC, 50/60 Hz 230 V AC, 50/60 Hz
-15 %, 50/60 Hz -15 %, 50/60 Hz
2 VA 2.3 VA 2.3 VA 1.4 - 1.9 W 1.2 - 3,2 W
(depending on the switching status) (depending on the switching status)
16 A 16 A 16 A 16 A 10 A
10 A 4A 4A 6A 6A
IP20B IP20B IP20B IP20 IP20
-10°C to +50°C -25°C to +55°C -25°C to +55°C -30 °C to +55 °C -30 °C to +55 °C
1 s on 1 million years thanks ± 0.5 s per day ± 0.5 s per day Without antenna: ± 0.5 s per day at 20 °C Without antenna: ± 0.5 s per day at 20 °C
to the synchronisation on the DCF at 25°C at 25°C With antenna: 1 s on 1 million years (7) With antenna: 1 s on 1 million years (7)
Frankfurt's DCF77 radio station
via the ANT DCF
12 years 10 years 10 years 10 years 10 years
4 years 10 years 10 years 10 years 10 years
(6) French, english, italian, spanish, german, portuguese, dutch. (7) Thanks to the synchronisation on the DCF Frankfurt's DCF77 radio station via the DCF antenna
or GPS antenna.
P116861
P116862
P116616
Function
bb They operate on hourly, daily or weekly cycle: the same program is repeated hour after hour (IH 60mn), day after day (IH 24h)
or week after week (IH 7j, (IHH 7j)
bb The program can be overriden On
Wiring diagrams
1 2 3 L N
1 2 3 L N
P116863
P111614
P111615
P111613
230 V AC +10 %, -15%, 110-230 V AC +10 %, -15%, 230 V AC, ±10 %, 230 V AC, ±10 %, 230 V AC, ±10 %,
50 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
2.5 VA 2.5 VA 2.5 VA 2.5 VA 2.5 VA
16 A 16 A 16 A 16 A 16 A
4A 4A 4A 4A 4A
P140493
P93581
P140494
Function
Consists of a programming device, Consists of a programming device, Saving and duplicating programs
a memory key, a CDROM a CDROM and a 1.5 m USB cable For IHP+ 1c/2c, For ITA 1c and ITA 4c
and a 2 m USB cable For ITA 1c and ITA 4c IHP 1c 18 mm,
For IHP+ 1c/2c, IHP+ 1c 18 mm
IHP 1c 18 mm,
IHP+ 1c 18 mm
Mounting
– Located on front face
Technical spécifications
Degree of protection – – –
Operating temperature – – –
P140492
P140491
Antenna for IHP DCF Antenna for ITA 1c Antenna for ITA 1c They are used to program a larger
and ITA 4c and ITA 4c number of sequences for:
bb IH 24h 2c ARM (15337)
bb IH 24h + 7j 1+1c ARM (15366)
bb 5 IHP DCF maximum per antenna, bb 10 ITA maximum per antenna, bb 10 ITA maximum per antenna, 1 bag containing:
maximum distance between the IHP maximum distance between the ITA maximum distance between the ITA bb 5 red
and the antenna: 200 m and the antenna: 200 m and the antenna: 200 m bb 5 green
bb Outside the electrical switchboard, bb Outside the electrical switchboard, bb Outside the electrical switchboard, bb 5 white
outdoors, under shelter outdoors, under shelter outdoors, under shelter bb 5 yellow
15858 CCT15960 CCT15970 (1) 15341
Programming principle
bb For the digital time switches, this consists of memorising the days and times
of the required switching operations.
bb For the mechanical time switches, this is performed by positioning captive
segments or jumpers on a switching dial.
Example
bb Controlling an air conditionner in a hairdressing salon:
Monday (1) Tuesday Wednesday Thursday (2) Etc.
On n° 1 08 h 30 08 h 30 08 h 30 Switch on
Off n° 1 12 h 00 12 h 00 Switch off
On n° 2 13 h 30 13 h 30 Switch on
Off n° 2 20 h 00 20 h 00 20 h 00 Switch off
(1)
Closed on Mondays
(2)
Non-stop
Lets you control starting and stopping of one 7 days weekly programming
to 4 groups of loads according to a weekly cycle, Example
that can be different each day, repeated each
bb Controlling an air conditionner in a hairdressing salon:
week.
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
On n° 1 09 h 00 09 h 00 09 h 00
Off n° 1 12 h 00 12 h 00
On n° 2 14 h 00 14 h 00
Off n° 2 20 h 00 20 h 00 20 h 00
On n° 3 8 h 30 8 h 30
Off n° 3 12 h 30 12 h 30
On n° 4 14 h 30 14 h 30
Off n° 4 21 h 00 21 h 00
Programming
bb Programming of a pulse takes up 2 memory spaces.
bb Combination of the two order types (pulse and latched) is possible on the same
channel.
Lets you create special programs for dated days. Programming special days.
Example
bb Controlling lighting and heating in a school:
vv basic programming: program lighting (channel 1) and heating (channel 2):
Monday Tuesday Wednesday Thursday Friday Saturday Sunday
Channel 1: lighting
On 07 h 00 07 h 00 07 h 00 07 h 00 07 h 00 – –
Off 20 h 00 20 h 00 16 h 00 20 h 00 16 h 00 – –
Channel 2: heating
On 06 h 00 06 h 00 06 h 00 06 h 00 06 h 00 – –
Off 18 h 00 18 h 00 12 h 00 18 h 00 12 h 00 – –
vv dated programming: periods of non-operation, school holidays, etc.
Just memorise an Off at the start and another Off at the end of each period
of absence:
Holidays
Winter Spring Summer Autumn End of year
Channel 1: lighting
Off Date 20 feb. 17-apr 07-july 23 oct. 18 dec.
Time 12 h 00 17 h 00 12 h 00 17 h 00 12 h 00
Off Date 08-march 03-may 9 sept. 2 nov. 4 jan.
Time 01 h 00 01 h 00 01 h 00 01 h 00 01 h 00
Channel 2: heating
Off Date 20 feb. 17-apr 23 oct. 18 dec.
Time 12 h 00 17 h 00 17 h 00 12 h 00
Off Date 08-march 03-may 2 nov. 4 jan.
Time 01 h 00 01 h 00 01 h 00 01 h 00
IHP 1c, 2c, +1c, +2c 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
PZ1 IHP 18 mm 1c, +1c 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
IHP DCF 1.2 N.m ⩽ 6 mm2 ⩽ 6 mm2
IH 60mn 1c SRM 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
24h 1c SRM, ARM 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
24h 2c ARM 1.2 N.m ⩽ 6 mm2 ⩽ 6 mm2
7j 1c ARM 2 screwless / pole 2 x 2.5 mm2 2 x 2.5 mm2
24h + 7j 1+1c ARM 1.2 N.m ⩽ 6 mm2 ⩽ 6 mm2
IH 18 mm 24h 1c SRM/ ARM 1.2 N.m ⩽ 6 mm2 ⩽ 6 mm2
IHH 18 mm 7j 1c ARM 1.2 N.m ⩽ 6 mm2 ⩽ 6 mm2
ITA 1c, ITA 4c 1.2 N.m ⩽ 6 mm2 ⩽ 6 mm2
IHP 1c/2c, IHP+ 1c/2c are mechanical compatible with electrical distribution comb busbar.
Weight (g)
Time switches
IHP 1c / 2c 170/ 205
IHP+ 1c / 2c 190/ 211
IHP 18 mm 1c / +1c 90
IHP DCF 244
IH 54 mm 60mn 1c SRM 208
24h 1c SRM/ARM 212 / 119
24h 2c ARM 216
7j 1c ARM 119
24h + 7j 1+1c ARM 223
IH 18 mm 24h 1c SRM / ARM 97
IHH 18 mm 7j 1c ARM 101
ITA 1c 152
ITA 4c 303
Dimensions (mm)
IHP time switches
6 60 6 60 5.5 60
18 44 44 18 44
45
19
85 82/85* 85 45 82 45 90 45 69
2P (18 mm) 5P: IHP DCF 2P (18 mm) 5P : IHP DCF 2P (18 mm)
*5P: IHP 1C/2C/+1C/+2C 5 P: IHP 1C/2C/+1C/+2C IHP 1C /+
80 84
93 93
6.5
32.5
2xø4
90 45 82 45 90 45
2P (18 mm) 6P (IH 24h 2c ARM, 6P (IH 60m 1c RM, IH 24h 1c RM ARM
IH 24h +7j 1+1c ARM) IH 7j 1c ARM)
90
90 45 45 90 45
58 58
58
63 63
4P 63 8P
75 52
89.5 11 28.3 11
31
38
22.8
5 5