M60S Restaurar

The document describes the procedure for backing up and restoring NC unit parameters using the BACKUP screen on an M60/M60S series NC unit. The backup procedure involves executing an emergency stop, selecting backup execution from the BACKUP screen, and waiting for backup completion. Restoration is similar but selects restoration execution. Both require stopping the PLC before starting.

Uploaded by

Fredy Cabrejo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
709 views3 pages

M60S Restaurar

The document describes the procedure for backing up and restoring NC unit parameters using the BACKUP screen on an M60/M60S series NC unit. The backup procedure involves executing an emergency stop, selecting backup execution from the BACKUP screen, and waiting for backup completion. Restoration is similar but selects restoration execution. Both require stopping the PLC before starting.

Uploaded by

Fredy Cabrejo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1.

M60 / M60S Series


1.5 How to backup / recover /replace the NC unit

D. Operation procedure
The data is backed up and restored by using BACKUP screen .
Refer following procedure for details on operations.

1.5.1 BACKUP Screen

If the page key NEXT


PAGE is pressed on the SETUP screen, the BACK UP screen will open.

[OPEN BACKUP] PARAM 3. 2/2

Open the BACKUP screen?

YES : "Y" "INPUT"

NO : "N" "INPUT"

#( )

WORK PROCESS I/O PAR SETUP MENU

Input "Y" in the setting area # ( ), and press the INPUT key. The BACKUP screen will open.

[BACKUP] PARAM 3

Please execute "EMERGENCY STOP" before operation.

#1 BACKUP BACKUP INFORMATION


#2 RESTORE SAVE DATE 01/09/05 16:24
SER.NO. M6123456789

WORK PROCESS I/O PAR SETUP MENU

The date and time that the backup data was saved, and the serial No. are displayed on this screen.

48
1. M60 / M60S Series
1.5 How to backup / recover /replace the NC unit

1.5.1.1 Backup Operations

The parameters are backed up in the maintenance memory cassette with the following steps.

(1)
Execute emergency stop.
#( ) ( )
"EMG EMERGENCY" will appear at the EMG EMERGENCY
operation message area.
WORK PROCESS I/O PAR SETUP MENU

(2)
Input "1" at the setting area # ( ),
and press the INPUT key. #(1) ( ) PLC STOP Y/N
EMG EMERGENCY
"PLC STOP Y/N" will appear at the
WORK PROCESS I/O PAR SETUP MENU
message area.

(3)
Input "Y" at the setting area ( ),
and press the INPUT key. #(1) ( Y) BACKUP EXEC Y/N
EMG EMERGENCY
"BACKUP EXEC Y/N" will appear at the WORK PROCESS I/O PAR SETUP MENU
message area.

(4)
Input "Y" at the setting area ( ),
and press the INPUT key. #(1) ( Y) BACKUP EXECUTION
EMG EMERGENCY
(a) The message "BACKUP EXECUTION"
WORK PROCESS I/O PAR SETUP MENU
will appear while the parameters are
being backed up.

(b) The message "BACKUP COMPLETE"


will appear when backup is completed.

#( ) ( ) BACKUP COMPLETE
EMG EMERGENCY
WORK PROCESS I/O PAR SETUP MENU

Note 1 Other screens cannot be opened during this operation.


Note 2 If the PLC is already stopped, step (3) is skipped.
The PLC will not start running even when the operations are completed.
Note 3 If the INPUT key is pressed without inputting anything at the "~Y/N" display, the error "E01
SETTING ERROR" will occur.
Note 4 Even if the PLC RUN/STOP changeover is prohibited (R2925/bit2 ON), the PLC will stop
with step (3).

49
1. M60 / M60S Series
1.5 How to backup / recover /replace the NC unit

1.5.1.2 Restoration Operations

The parameters are restored from the maintenance memory cassette to the NC with the following steps.

(1)
Execute emergency stop.
#( ) ( )
"EMG EMERGENCY" will appear at the EMG EMERGENCY
operation message area.
WORK PROCESS I/O PAR SETUP MENU

(2)
Input "2" at the setting area # ( ),
and press the INPUT key. #(2) ( ) PLC STOP Y/N
EMG EMERGENCY
"PLC STOP Y/N" will appear at the
WORK PROCESS I/O PAR SETUP MENU
message area.

(3)
Input "Y" at the setting area ( ),
and press the INPUT key. #(2) ( Y) RESTORE EXEC Y/N
EMG EMERGENCY
"RESTORE EXEC Y/N" will appear at WORK PROCESS I/O PAR SETUP MENU
the message area.

(4)
Input "Y" at the setting area ( ),
and press the INPUT key. #(2) ( Y) RESTORE EXECUTION
EMG EMERGENCY
(a) The message "RESTORE EXECUTION"
WORK PROCESS I/O PAR SETUP MENU
will appear while the parameters are
being restored.

(b) The message "RESTORE COMPLETE"


will appear when the restoration is
completed. #( ) ( ) RESTORE COMPLETE
EMG EMERGENCY
WORK PROCESS I/O PAR SETUP MENU

Note 1 Other screens cannot be opened during this operation.


Note 2 If the PLC is already stopped, step (3) is skipped.
The PLC will not start running even when the operations are completed.
Note 3 If the INPUT
key is pressed without inputting anything at the "~Y/N" display, the error "E01
SETTING ERROR" will occur.
Note 4 Even if the PLC RUN/STOP changeover is prohibited (R2925/bit2 ON), the PLC will stop
with step (3).