0% found this document useful (0 votes)
104 views2 pages

General Information: Location A Location B

This OTDR report summarizes a fiber optic cable test between locations A and B that failed. Key details include: - The span length was 0.4651 km with an average loss of 1.162 dB/km and total span loss of 0.541 dB. - The average splice loss was 0.164 dB and maximum splice loss was 0.189 dB. - There was a non-reflective event at 0.2696 km with a loss of 0.139 dB and another at 0.4186 km with a loss of 0.189 dB. - The test failed due to the span loss exceeding the 20 dB threshold.

Uploaded by

Nik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views2 pages

General Information: Location A Location B

This OTDR report summarizes a fiber optic cable test between locations A and B that failed. Key details include: - The span length was 0.4651 km with an average loss of 1.162 dB/km and total span loss of 0.541 dB. - The average splice loss was 0.164 dB and maximum splice loss was 0.189 dB. - There was a non-reflective event at 0.2696 km with a loss of 0.139 dB and another at 0.4186 km with a loss of 0.189 dB. - The test failed due to the span loss exceeding the 20 dB threshold.

Uploaded by

Nik
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OTDR Report Fail

General Information
Filename: =E8.sor
Test date: 25/08/2022 Customer:
Test time: 12:31:58 Company:
Cable ID: idea Fiber ID: F61
Job ID:
Comments:

Locations
Location A Location B
Location GND JTP
Operator
Model MAX-715B-P-M1-EA
Serial number 837818
Calibration date 12/05/2015 (UTC)

Results
Span length: 0.4651 km Average loss: 1.162 dB/km Injection level: 24.8 dB
Span loss: 0.541 dB Average splice loss: 0.164 dB
Span ORL: <15.22 dB Maximum splice loss: 0.189 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 11.513 dB/km A-B average loss: 25.869 dB/km
a 0.5002 20.298 A-B LSA loss: 0.250 dB 4-point Event Loss: 10.191 dB
A 1.0004 12.940 A-B ORL: 50.67 dB Maximum reflectance: -65.7 dB
B 1.5007 0.000
b 2.0009 0.000

Signature: _______________________________ Date: 8/25/2022 Page 1 of 2


OTDR Report Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- >-22.3 0.000
Section 0.2696 0.135 0.500 0.135
Non-Reflective 2 0.2696 0.139 0.274
Section 0.1490 0.072 0.486 0.346
Non-Reflective 3 0.4186 0.189 0.536
Section 0.0466 0.005 0.100 0.541
Reflective 4 0.4651 --- -44.4 0.541

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1550 nm
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1550 (9 μm)
Range (km) 5.0000
Pulse (ns) 100
Duration (s) 15

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 8/25/2022 Page 2 of 2