0% found this document useful (0 votes)
65 views5 pages

KP D150P

1) The document provides technical specifications for KP-D150P and KP-D165S generating sets from KEYPOWER, including engine, alternator, and control system details. 2) The KP-D150P is a 150kVA prime power set and the KP-D165S is a 165kVA standby power set. Both are powered by a Deutz 6-cylinder engine and include a fuel tank, radiator, and digital auto-start control panel. 3) Key details provided are voltage regulation, frequency stability, dimensions, engine specifications, alternator specifications, and control system options.

Uploaded by

Derek Chen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views5 pages

KP D150P

1) The document provides technical specifications for KP-D150P and KP-D165S generating sets from KEYPOWER, including engine, alternator, and control system details. 2) The KP-D150P is a 150kVA prime power set and the KP-D165S is a 165kVA standby power set. Both are powered by a Deutz 6-cylinder engine and include a fuel tank, radiator, and digital auto-start control panel. 3) Key details provided are voltage regulation, frequency stability, dimensions, engine specifications, alternator specifications, and control system options.

Uploaded by

Derek Chen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

KP-D150P (WP6D152E200)

Generating set Technical Data Sheet

FUZHOU GFF KEYPOWER EQUIPMENT CO., LTD


Add: No. 760 Qian Rd. Fuwan Industrial Zone Fuzhou, China 350006
http://www.gff-keypower.com
info@keypower.biz , sales@keypower.biz
Tel:(0086)-591-83568232 Fax:(0086)-591-83568345
Powered by WP6D152E200
DEUTZ Engine Generating Set

STANDARD SPECIFICATION
General features:
● Composed of DEUTZ diesel engine and Stamford or
Leroy Somer or Keypower brushless alternator
● 24V DC start motor and storage battery
● Brushless, Self-excited, IP23, insulation class H alternator
● 50℃ radiator as standard
● Key start panel control system as standard, digital auto-start
panel is optional
● 8-hour operation fuel tank on top
● Optional open type or silent type
● All generator sets are gone through rigorous testing before
being released to the market place, including 50% load,
75% load, 100% load , 110% load and all protection function
(overspeed stop, high water temperature, low oil pr essure,
battery charging fail, emergency stop)

Genset Main Technical Data


3-PH, 50Hz@1500RPM, 230/400V (Can Be Made According To Customers’ Special Requirements)

Genset Specification Engine Specification


KVA Keypower
GENSET Cons
dB(A) Tank alternator
MODEL 100% Model Cyl. Gov. Asp.
ESP PRP @7m (L) Model
(L/H)
KP-D150P 165 150 30 75 300 WP6D152E200 6 M TCA DG274FS14
KP-D165S 165 150 30 75 300 WP6D152E200 6 M TCA DG274FS14

1) Available in various voltages


2) To show KEYPOWER Generating Sets Model
KP-D165S, it is the Standby power 165kva generation set.
KP-D150P, it is the Prime power 150kva generating set.
3) ESP=Standby power standby duty, operation under variable load, without overload.
PRP=Prime power continuous duty operation, under variable load, 10% overload permissible 1/12hr.
4) E=Electronic speed governor;
M=Mechanical speed governor
5) Asp=Aspiration;
NA=Naturally Asp;
TC=Turbocharged;
TW=Turbocharged after cooled;
TCA= Turboc harged air-air after cooled
6) Technical data is subject to work test conditions

http://www.gff-keypower.com Page: 2/5 Specifications may change without Notice


Powered by WP6D152E200
DEUTZ Engine Generating Set

RELIABLE PERFORMANCE

Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
● Power factor Between 0.8~1.0 lag
● From no load to full load, any steady load
● Speed droop variation under 4.5%
Frequency/Speed undulation
● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%.
● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%

Effect factor of telecom


● TIF( MA MG1-22) better than 50
● THF( BS EN60034) better than 2%

CRITERION

● ISO8528, GB/T2820
● EN12601:2001, EN60034-22:1997, EN60204-1:2006
● ISO9001:2000 Quality Control System

DIMENSIONS AND WEIGHT

Open Type
Overall size (L*W*H)
2600*900*1500
Weight: 1550kg

Silent Type
Overall size (L*W*H)
3250*1100*1750
Weight: 1900kg

http://www.gff-keypower.com Page: 3/5 Specifications may change without Notice


Powered by WP6D152E200
DEUTZ Engine Generating Set

ENGINE SPECIFICATION
DEUTZ Diesel Engine
Technical Data

Engine Model WP6D152E200


Number of Cylinders 6
Cylinder arrangement Vertical in-line
Cycle Four stroke
Aspiration Turbocharged Air-Air Aftercooled
Bore×Stroke (mm×mm) 105*130
Displacement (Liter) 6.75
Compression Ratio 15.5:1
Prime Power/Speed (kW/rpm) 138/1500RPM
Standby Power/Speed (kW/rpm) 152/1500RPM
Speed Governor Mechanical

Cooling System Water-cooled, 50℃ radiator as standard

Speed Stability (%) ≤5%


Total lubrication system capacity (L) 22
Coolant capacity (without radiator) (L) 27
Fuel Consumption at 100% Load (L/H) 30
Starter Motor DC24V
Start type Electrical

ALTERNATOR SPECIFICATION

Keypower Alternator (Standard)


Leroy Somer and Stamford Alternator (Optional)
Technical Data

Alternator Model Keypower DG274FS14

Exciter type Brushless, Self-excited

Power factor 0.8

Voltage Adjust range ≥5%

Voltage Regulation NL-FL ≤±0.5%

Insulation Grade H

Protection Grade IP23

http://www.gff-keypower.com Page: 4/5 Specifications may change without Notice


Powered by WP6D152E200
DEUTZ Engine Generating Set

CONTROL SYSTEM

1. Standard: Smartgen HGM6120 AMF Digital Controller


Providing the standard functions as follows:
(Also can be made according to the customers’ special requirements)
*Automatic Start/Stop
*Settings can be adjustable via key buttons on front panel
*3 start attempts failure and Automatic Crank Disconnect
*Parameters display (V/A/Hz/Hour)
*Engine monitoring and protection
*Charge alter nator exciting and Charge alternator fail alarm
*Running hour counting (1) HGM6120
*Emergency stop pushbutton
*Alarm System: Over speed、High Engine Temperature
Low Oil Pressure、Charge Fail
*Protection System:Over speed、High Engine Temperature、Low Oil
Pressure 、 Emergency Stop. And the other protection function
pre-setting

Digital Auto-start Generator controller integrating digital, intelligent


and network techniques is used for automatic control system of diese l
generator. It can carry out functions including automatic start/stop, data
measure and alarming. Optionally assembled with the ATS, it can carry (2) DSE7320
out auto-switching between the outer power and generating set power.
(AMF)

2. Option: Deepsea DSE7320 AMF Digital Auto Start


3. Option: ComAp AMF25 Digital Auto Start
4. Option: Deepsea DSE3110 Digital Auto Start

(3) AMF25

(4) DSE3110

http://www.gff-keypower.com Page: 5/5 Specifications may change without Notice